Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RISK MANAGEMENT (2)
Invoice 6630 ROSEDALE HWY. #B BAKERSFI'ELD, CA 93308 DATE INVOICE # 661-588-2777 9/19/2002 6019 BILL TO LOCATION SERVICED PEPSI COLA PEPSI COLA CHAD BUECHEL 215 E. 21ST STREET 215 E. 21ST STREET BAKERSFIELD, CA BAKERSFIELD, CA 93305 P.O. NUMBER TERMS DATE OF SERVICE JOB # ACCOUNT # SCOTT Due on receipt 9/19/2002 9318 6351188 QTY. ITEM CODE DESCRIPTION PRICE EACH AMOUNT I MISC DRAIN VALVE 58.00 58.00T 1 MISC RE-TEST MACHINE 50.00 50.00 2.5 L43 / LABOR PER HOUR RATE 49.00 122.50 20 MILEAGE PER MILE RATE 0.50 PROBLEM: REPAIR AND RE-TEST OVERSPILL BOX AT FUEL TANK. RESOLUTION: REPAIRED FUEL TANK OVERSPILL BOX AS NEEDED WITH VALVE. SET UP AND RE-TEST AND PASS SB98g. TESTING OF YOUR SITE IS NOW COMPLETE AND PASSED ALL PARAMETERS. p..~~/~ JOB COMPLETE - THANK YOU. 4.06 Total $242.56 SALES AGREEMENT: It is agreed that, if collection is made by suit or othenvise, I/we agree to pay a FINANCE CHARGE (NOT TO EXCEED THE MAXIMUM LEGAL RATE) computed after 20 days from the due date On the previous balance after deducting current payments and/or credits until fully paid. I/we also agree to pay all collections costs and including attorneys fees as may be adjudged by the court, and waive all rights at any claims exempted under State Laws, and will not remove property without prior written consent of BSSR, Inc. from original place of services provided/delivery/installation of parts. Merchandise not returnable unless approved by BSSR, Inc.(SELLER). BILL TO: .. SER~H~E_~,b~ ~_..~ ~" ST~TION~. NAM E~.~,~ /~..~ _ PHONE ~ STORE BILL TO ADDRESS: SERVICE ~TA~ON ADDRESS: ~ PO~ OR INClDENT~ REQUESTED BY: ,EPORTEDPROBLEM:, ~' ~ :~ ' /4'~':~ - ::-'{ ~ ~X W~OO~EO? TECHNICIAN, COD: CHARGE ' - MATERIAL CHARGES I ~ :~ ~ /~ MATERIAL DESCRIPTION SERVICES / REPAIRS PERFORMED QTY. PRICE AMOUNT TOTALIZER READINGS - PUMP NUMBER - SERIAL NUMBER WERE CORES RECEIVED? MODEL NUMBER TOTAL MATERIAL ~. ~ SERIAL~ ~ I I ~ ~ SALES T~ ON TOTAL MATERIAL ' READ[NGS BEFORE TOTAL TRAVEL TIME TOTALS ~ TOTAL MILEAGE REMARKS: AM CAUSE DEPARTURE TIME REMEDY TOTAL TIME ON SITE SEa'ViCE PERSON (PRINT NAME) SERVICE PERSON (PRINT NAME) AUTH D PERSON (PRINT NAME)/' ~ -- ' X~ // ~/ / TOTAL ~~S SIG TURE ' ' SERVICE PERSON'S SIGNATURE A~¢R~ED PERSON'S~IGNATURE[ / S G E ENT~tisa9~edthat~if~ecti~nismadebysuit~r~the~ise'~wea9reet~payaF~NANcEcHARC:(N~TT~EXcEEDTHEM~i~MLEGALRATE)c~mputedafter2~daysfr~mtheduedate~ntheprevi~usba~anceafte~ deductin~ current paymen~ndlor credil~ until fully paid. I/we also agree to pay all collections costs and includin9 atto ~eys fees as may be ad}udged by the cou~, and waive all rights at any claims exempted under State L~ws, and wil~ not remove prope~y with ~ut prio~ wri~ ~o~sent of B~R, inc. from ori~i~al plaoe of se~ioes providedldeliverylinstall~ion of part~ Merchandise not returnable u~less approved ~y B~R lnc.(~ELLE~) BUSINESS/DEAPRTMENT NAME: PROJECT DESCRIPTION: PROJECT NUMBER: DATE: NAME: CHGD: COMMENTS: PROJECT COMPLETION: ~/,zY(P ,~Xe~L~] DATE: ~"/z ~':~~ OUSM-ATERIAIDIVISION ~ TIME CHARGE BUSLNESS/DEAPRTMENT NAME: Peri '~d ~J 'ADDRESS: 0~I6 [, ov3l6~' PROJECT COMPLETION: DATE: ~. ~, ' CITY of BAKERSFIELD ~ ~'i~'~,~ ~AZARDOUS MATERIALS DIVISIO~~ FIRE DEPARTMENT T I ME CHARGED 2101 H STREET S D. JOHNSON · BAKERSFIELD, 93301 FIRE CHIEF 32%3911 BUSINESS NAME: ~' TIME DATE: · N~E: CHGD: CO~ENTS: --'.-~ ~ CITY of BAKERSFIELD ~~ "wec.4R~., ,.~,~ HAZARDOUS 'MATERIALs DIVI-SI ' FfRE DEPARTMENT S. D. JOHNSON T I ME CHARGED FIRE CHIEF · 2T01 H STREET BUSINESS NAME: 326-39~ DATE: NAME: TIME CHGD: COMMENTS: II -~-L ~ I 2N · ' ~ ' I ,,,,, 0 BAKERSFIELD FIRE DEPARTMENT ENVIRONMENTAL SERVICES 1715 Chester Ave. · Bakersfield, CA 93301 Business Phone {661) 326-3979 · FAX {661) 326-0576 FAX Transmittal COMPANY: FAX No. COMMENTS: Fo*m ~ OMB No. 20500072 FacllitYldentlflcatlon .Owner/Operator Name Tier Two · street 'Tt~ E:. ,,2.1 s~ ~TREE--~' MailAddress -~o'~c~as.e EMERGENCY city 'J~a~.~')6 L.~ County k:F..R~J State ~/q Zip q :33 o~- AND Emergency Contact HAZARDOUS s~c Code ~ O ~r (o Dun & Brad Number CHEMICAL Name ~ H,~/D ~ uE c>/~-.t_ Title Important: Read all in~tructions before completing Reporting Period From January 1 to December 31,19 'ii~ii~ ~ i~i~!~i~i~i~i~ii~!!~i~ Chemical Description and Health Inventory ~ · =., e Storage Codes and Locations . [ (Non-Confidential) (cheek all that appl~ ..~,qtora~e Locatio~ Socr~ ~[Fire Max. Dally Pi t q- A(fL~..~ ~U. (e Chem. Name .~'iJ~-Fu~tC._ ~4-C~/~ ' [ ] Sudden Release ~ Amount (code) of Pressure Check all [ ] '~,. [ ] 'jcL, l ] [ ] ~ Reactivity ~ Avg. Dally Amount i thetapply Pure Mix Solid Uquld Gas EH$ ,~lmmediate (acute) (code) EHS Name J~ Delayed (chronic) I :3 I v, I -q' / No. of Days On-sEe (days). .-'T'O'r'~,L. om m, t ~T~J ,t~. - Trade Chem. Name &Ob~/r,1 ~¥L~-cx~t)l~. [] Sudden Release I ~ I dr I Amount(code) [ ] [ ] ~,}L,React~ I t~ I q I Avg. Dally Amount "14-o~ PU ct" f~¢.~ c~:~, [] )L. [] ~at apply Pure Mix Solid O,~ EHS ~ Immediate (acute) (code) EHS Name [:~.Delayed (chronic) I ~ I 6, I ~- / No. of Days On-site (days) -- To'r'~-c_ e ~ /Ht~T~t'.-~ - Trade CAS G ~ ~t-7(o .~O ?... s~r~t ~J~Flra Max. Daily I ~ i ~ FUEl- tsc,q~,O Chain. Name L~iF---qP--L- FL/~-~- [] Sudden Release ~ Amount (code) I ~1~ q~HI('('~'~ ? of Pressure Avg. Daily Amount Checkall [] [] ~ [] [] [] Reactivity I O IS" I(code) ~[~ Immediate (acute) i that app/y Mix Solid UaJd Oa, EHS -[] Delayed (chronic) I ~ I G I .~' / No. of Days I EHS Name On-site (days) Certification freed end xi~n ttfler eom/ale'/rig att ~¢ct/om) OptiOnal Attachment.~ I cedlfy under penalty of law that I have personally examined and am familiar with the Information subm~ed In pages one through 7 , and that based ~ I have attached = ..,~ plan on my inquiry of these Indlvlduala respen.lbla for obtain'rig the Information, I ?J.}~.:~e ~m~ Is true. accurate' and c°mpleta'~,4,~:~ ~ot-~C~4~--/..- ~ '~..~ °o?. {~ ~0 [[ ] I have attached -~ liat of site ooordinate abbreviations] I have attachec t description of dikes and other Nameeuthortzedand officlalrepresentattvetitle of ow~er/operotor OR owner/operator'a Signature Date signed ssfeguard$ m~ .%ires 06/29/01 FRI 08:05 FAX 6616351184 PEPSI BAKERSFIELD WRHS ~002 L367629] 8512253098~ 06/29/01 09:~6 o£ 3 44024 *MA~IAL SAFETY DATA SHEET* Page i of 2 MEDICAL EMERGENCY ONLY, 24 HOUR SERVICE- 1-800-328-0026 KLENZADE, Div. of Ecolab Inc. Product Information: 1-612-451-4255 Ecolab Ctr. St. Paul MN $5102 Date of I~sue; August 27, 1992 1.0 IDENTIFICATION / 1.1 Product Name:~BEIT~OSHEEN CA 1.1 Product Ty~e' Alkaline bottle wash for California ++ Section 2 Provides SARA Section 313 Reporting Information ++ 2.0 HAZARDOUS C .C..~P. ONENTS / (mg/m3) % TWA Other 2.1 Sodium hydroxide (caustic soda) 1310-73-2 26 2 C 2 C This product contains no other component considered hazardous according to the criteria of 29 CFR 1910.1200. UNK = Unknown at this time TWA = OSHA 8 Hour Average STEL = 15 Minute Average ~ = Ceiling Limit; Do Not Exceed 3.0 PHYSICA~ DATA / 3.1 Appearance- Clear to hazy, an~er liquid 3.2 Solubility in Water: Complete 3.3 pH: 12.0 (O.1%) 3.4 Boiling Point: >212 deg F 3.5 Specific Gravity: 1.30 4.0 FIRE AND EXPLOSION DATA / 4.1 Special Fire Hazards: None 4.2 Fire Fighting Methods- Product does not support combustion. 5.0 REACTIVITY DATA / 5.1 Stability: Stable under normal conditions of handling. 5.2 Conditions to Avoid' Reacts violently with acids. Reacts with soft metals such as aluminum and zinc. 6.0 SPILL OR LEAK PROCEDVRES / USE PROPER PROTECTIVE E~UIPMENT 6.1 Cleanup' Dike or dam large spills. Pump to containers or soak up on inert absorbent. Flush residue to sanitary sewer. Rinse small amounts to drain where possible. Dike or dam large spills; pump to containers or soak up on inert absorbent. Flush residue to sanitary sewer; rinse area thoroughly. 6.2 Waste Disposal- Consult state and local authorities for restrictions on ~isposal of chemical waste. 06/29/01 FRI 08:05 FAX 6616351184 PEPSI BAKERSFIELD WRHS [~003 t387~2~1 ~53.22530~9~ 06/2.~/01 09:~ o£ 3 Product: BEVROSHEEN CA Page 2 of 2 KLENZADE, Div. of Ecolab Inc. 962290 ~IEDIC_D.L F/~ERGENCY ONLY, 24 HOUR SERVICE: 1-800-328-0026 7.0 HEALTH HAZARD DATA / DANGER 7.1 Effects of Overexposure to Concentrate: Skin and Eyes: CAUSES ~EVERE CHEMICAL BURNS. Eye contact may cause blindness. Harmful contact may not cause immediate pain. ++ Immediate water flushing is vital in case of eye contact. ++ If Swallowed: HARMFUL OR FATAL. Causes chemical burns of mouth, throat and stomach. If Inhaled: Damages airways and lungs, depending upon amount and duration of exposure. Effects can vary from slight irritation to bronchitis or pneumonia. People with asthma or other lung problems may be more affected. 8.O FIRST AID / 8. i Eyes: Immediately flush with plenty of cool running water. Remove contact lenses. Continue flushing for at least 15 minutes, holding eyelids apart to ensure rinsing of the entire eye. CALL A PHYSICIAN IMMEDIATELY. 8.2 Skin; Immediately flush skin with plenty of cool running water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse.. 8.3 If Swallowed: Rinse mouth at once; then drink i or 2 large glasses of water or milk. DO NOT induce vomiting. NEVER give anything by mouth to an unconscious person. 8.4 If Inhaled: Immediately move to fresh air. CALL A POISON CONTROL CENTER OR PHYSICIAN IMMEDIATELY 9 0 PROTECTI%"~ M~..~SUR~S / 9.~ CONCENTRATE: Respiratory: Avoid breathing dusts or mists of this product. Skin; Rubber gloves - protective cuff or gauntlet type preferred. Eyes: Use chemical splash goggles. For continued or severe exposure wear a face shield over the goggles. 9.Z This product reacts with reducing sugars in food products to form lethal carbon monoxide gas. Take proper precautions, especially when using this product in an enclosed or semi-enclosed area - monitor for carbon monoxide. 10.0 ADDITIONAL INFORMATION/PRECAUTIONs / KEEP OUT OF REACH OF CHILDREN The above information is believed to be correct with respect to the formula used to manufacture the product. As data, standards and regulations change, and conditions of use and handling are beyond our control, NO WARRANTY, EXP~,KSS OR IMPLIED, IS MADE AS TO THE COMPLETENESS OR CONTINUING ACCURACY OF THIS INFORMATION. 06/29/01 FRI 08:06 FAX 6616351184 PEPSI BAKERSFIELD WRHS ~004 [367630J 8512253095~ 06/29/01 09:47 o£ 2 45468 *MA~IAL SAFETY DATA SHEET* Page i of 2 MEDICAL EMERGENCY ONLY, 24 HOUR SERVICE' 1-800-328-0026 KLENZADE, Div. of Ecolab Inc. Product Information- 1-612-451-4255 Ecolab Ctr. St. Paul MN 55102 'Date of Issue: May 25, 1994 1.0 IDENTIFICATION / 1.1 Product Name:~KONDUCT ALKALINE CLEANER 1.2 Product Type' Multi purpose alkaline cleaner ++ SARA 313 Toxic Chemical~, If Present, Are Preceded by "#" ++ 2.0 HAZARDOUS COMPONENTS / (mg/m3) % PE___~L Other 2.1 Sodium hydroxide (caustic soda) 1310-73-2 15 2 2 C 2.2 This product contains no other components considered hazardous - according to the criteria of 29 CFR 1910.1200. UNK ~ Unknown at this time PEL = OSHA 8 Hour Average STEL = 15 Minute Average ~ = Ceiling Limit; Do Not Exceed 3.0 PHYSICAL DATA / 3.1 Appearance' Clear, light amber liquid; mild sweet odor 3.2 Solubility in Water: Complete 3.3 pH: (100%) >13 Use Solution pH: 2% >13 3.4 Initial Boiling Point' >212 deg F 3.5 Specific Gravity: 1.209 (68 deg F) 4.6 FiRE AND EXPLOSION DATA / 4.1 Special Fire Hazards' None 4.2 Fire Fighting Methods: Product does not support combustion. 5.0 REACTIVITY DATA / 5.1 Stability: Stable under normal conditions of handling. 5.2 Conditions to Avoid: Reacts violently with acids. Reacts with soft metals such as aluminum and zinc. 6.0 SPILL OR LEAK PROCEDURES / USE PROPER PROTECTIVE EQUIPMENT 6.1 Cleanup: Dike or dam large spills. Pump to containers or soak up on inert absorbent. Flush residue to sanitary sewer. 6.2 Waste Disposal: Unused product as a waste is Corrosive (D002) by RCRA criteria. 06/29/01 FRI 08:06 FAX 6616351184 PEPSI BAKERSFIELD WRHS ~005 [~5'/530J UblZZ53088 06/Z9/01 09:~7 of 2 Product: KONDUCT ALKALINE CLEANER Page 2 of 2 KLENZADE, Div. of Ecolab Inc. 900878-02 MEDICAL EMERGENCY ONLY, 24 HOUR SERVICE: 1-800-328-0016 7.O HEALTH HAZARD DATA / DAN~ER - POISON 7.1 Effects of Overexposure to Concentrate: Skin and EYes: CAUSES SEVERE CHEMICAL BURNS. Eye contact may cause blindness. Harmful contact may not cause immediate pain. ++ I~uuediate water flushing is vital in case of eye contact. ++ If Swallowed: HARMFUL OR FATAL. Causes chemical burns of mouth, throat and stomach. If Inhaled: Damages airways and lungs', depending upon amount and duration of exposure. Effects can vary from slight irritation to bronchitis or pneumonia. People with asthma or other lung problems may be more affected. 8.0 FIRST'AID / IMMEDIATELY CALL A POISON CONTROL CENTER, A PHYSICIAN OR THE ECOLAB 24-~OURMEDICAL E~RGENCY NUMBER (1-800-328-0026) 8.1 Eyes: Immediately flush with plenty of cool running water. Remove contact lenses. Continue flushing for at least 15 minutes, holding eyelids apart to ensure rinsing of the entire eye. CALL A PHYSICIAN IMMEDIATELY. 8.2 Skin: Immediately flush skin with plenty of cool running water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse. 8.3 ~f. Swallowed: Rinse mouth at once; then drink i or 2 large glasses of water or milk. DO NOT induce vomiting. NEVER give anything by mouth to an unconscious person. 8.4 If Inhaled: Immediately move to fresh air. IMMEDIATELY CALL A POISON CONTROL CENTER, A PHYSICIAN OR THE ECOLA~ 24-HOURMEDICAL E~XERGENCYNUMBER (1-800-328-0026) 9.0 PROTECTIVE MEASURES / 9.1 CONCENTRATE: ResDiratorv: Avoid breathing dusts or mists of this product. Skin: Rubber gloves - protective cuff or gauntlet type preferred. Eyes.: U~e chemical splash goggles. For continued or severe exposure wear a face shield over the goggles. 10.0 ADDITIONAL INFORMATION/PRECAUTIONS / KEEP OUT OF REACH OF CHILDREN The above information is believed to be correct with respect to the formula used to manufacture the product. As data, standards and regulations change, and conditions of use and handling are beyond our control, NO WARRANTY, EXPRESS OR IMPLIED, IS MADE AS TO THE COMPLETENESS OR CONTINUING ACCURACY OF THIS INFORMATION. 07/11/01 10:47 '~661 326 0576 BFD HAZ MAT DIV ~001 ***************************** *** ACTIVITY REPORT TRANSMISSION OK TX/RX NO. 0553 CONNECTION TEL ,823235313 CONNECTION ID START TIME 07/11 10:41 USAGE TIME 04'59 PAGES 6 RESULT OK ~_ B A K E R S F I E L D PUBLIC WORKS DEPARTMENT 1501 TRUXTUN AVENUE BAKERSFIELD, CALIFORNIA 93301 (661) 326-3724 July 23, 1999 RAULM. ROJAS, DIREC'I~R-CITYENGIJqEER ~[~'~Tr?*"~'~rl~'~"~-~h'a Mr. Joe Fonseca Pepsi Cola Bottling Co. 215 E 21st Street Bakersfield, CA 93305 Re: Notice of Violation for pH Limits on 6/29/99 for Permit No. 2-BK-0013 Dear Mr. Fonseca: Permit Violation After careful review of your second quarter self-monitoring pH charts, it has been determined that your facility discharged in violation of the subject permit upper pH limit on June 29, 1999. The final pH exceeded 12 units for approximately three-quarters of an hour (highest =13.0). The event is also a violation of Bakersfield Municipal Code Chapter 14.12 since it constitutes a discharge of hazardous waste as defined by California CCR Title 22 (pH 12.5 or greater). Enclosed is a photocopy of the 'flow, primary pH, and secondary pH charts for the time period in question. The primary pH chart also recorded 13.0 but for what appears to be a shorter duration than the final chart. Pretreatment Operation Problems Pepsi staff reported verbally that the mixer motor was not in the normal "Manual" position but switched to the "Automatic" position. The manual position provides constant mixing in the.primary zone of the vault and is necessary to avoid pass-through of wastewater through the system due to the frequent pumping cycles from the 'lift well (often at fifteen minute intervals). The "automatic" position only runs the mixer when the lift pump is operating. Although the baffles preceding the secondary/final pH monitoring zone help to equalize pH, there is no secondary chemical injection to further neutralize wastewater pH levels beyond the permit limits of 6.0 - 12.0 units. In this current situation, the primary chart data cannot be used to'refute the final pH chart data. We believe that the treatment vault must be constantly mixed to provide thorough mixing/pH equalization, proper neutralization to meet the permit limits, and to prevent pass-through. Please calibrate the primary and final pH electrodes at least on a weekly basis, as recommended in our July 1998 letter to you. Although the letter indicated weekly cleaning of the pH electrodes, we suggest daily cleaning due to the constant presence of an oily residue in each stage of the pretreatment system. A review of your pH calibration log sheet revealed that the primary was only calibrated four times in the past three · months and the secondary probe was calibrated six times in April, five times in May, and three times in June 1999. Daily cleaning of pH electrodes is essential to ensure efficient chemical injection and accurate pH monitoring. S:\l-indust~ial users\l 8-PCB\pcbnov2Q99.wpd Notice of Violation, Permit No. 2-BK-0013 July 23, 1999 Page'-2 In addition,.please determine if the aging pH recorders should be replaced or repaired. Both City staffand your staff have observed a problem regarding discrepancies between the pH values of the digital display compared to the strip chart recorder impact marks. If the recorders are not able to consistently and reliably record accurate pH data, it may be time to repair or replace them. We have verbally asked your staff to verify and note any discrepancies. These notes have been helpful for interpreting the charts at the end of each month, but cannot be relied on in the long term. Recommendations In summary, we highly recommend that you take the following actions: 1) operate the mixer motor on the primary pH zone in the "manual" setting; 2) calibrate all pH electrodes on a weekly, or more frequent, basis; 3) clean pH electrodes on a daily basis; 4) determine if the pH recorders need to be replaced or repaired. If you have any questions, please contact Timothy Ryan at (661) 326-3249. very truly yours, PAUL M. ROJAS Public Works Director By '? Wen-Shi Cheung Wastewater Supervisor II Enclosure TR cc: Jpb.K_atipu~a_n_r Pepsi-Cola, 215 E.21st Street Howard Wines - Offide of Ehvir~hmental Services S:\l-industrial users\18-PCB\pcbnov2Q99.wpd '~'"~'l ' - ~ t ,:' ,~ · !' i._. !'. ;" ''~ -i · ,:!~'~ i.._.; ~.i .... t ,ii' I '~ ~' ¥ "' "' 'q' ",'."...r,! THIS sHIPPING ORDER must be legibty filled in, i~ Ink; in indelible Pencil, or in Carbon, and retained by the Agent. Shipper's No, : carrier's Name: ~ ~3, ~',:~[-'r" t-~,t-' -~i_~¢"~ RECEIVED, subject to the classifications~ t~ in ~f}ec~ on t~e ~ate'of ~e i~e 0f this Bill of lading, at~~ (~.~ (Date) the prop~d~scr ~d ~elow n appa~n~goo~ o~er, except as nord (conten~ and conditio~of con~n~ of pack.es unknown), marked cons gne~and des~ ne~s sh~ b~ow, ~i~said company (the wot9 company Dei~g.~aers~oQ throughout th s contract as 'mean ag any pe~oa or co~omtion n possess on of the proD~y under the contact) agrees ~ carry ~ im usual pl~e of delivery at said desti~tion if on i~ own railroaa, water line, highway ropte or rou~s, or within the terri~ry of its highway operations other~se ~ deliver ~ another carrier on the rou~ ~ said destination. It is mutually a~reed~as to each carrier of all or.ny ~ 9aid pyopert~ 9yer a~ or ~y~ B of ~ding set fo~h 1) in the Uniform Fre' ht Cl~sffication in effect on the da~ hereof ff th s ~ a m or rail-wa~r s~pment or (2) in the applicable motor carr er c ~sification or ~rfff if this is a motor carrier shipment. Shipper hereby ce~ifies ~at he is familiar wit~alI the ~rms and conditions of the said bill'of ~ding, including those on theback ~hereof, set fo~h in the classification or ~riff which governs the tmnspo~ation of this shipment, anathe said ~rms and conditions are hereby ag~ed ~ by the shipper and accep~d for himse~ and his assign& Route Delivering Carrier Collect on Delivery $ (Mail or street address for purposes of notification only.) Consigned TO )~, ~,, Q>ff'y"' ~,~'~- '""~ v'~, ~T~..A,,-- . On Collect on ~)el~very Ship~the-~l"e{ter~"~OD" m--L~st -appear ~fom consignee's~me or as othe~ise provided in Item 430, Sec. 1. Destination ~--~. ~'t ~ ?-(~ Street (~(~~ ~ County ~_. ~ . State r~ Delivery ~ Address~ ~,~, r"~, ,~, ,~ *To be filled in only when shipper ~sims and go~er~ing tariffs~vid~o~elive~y ~re~t.) - ~ Car or Vehicle Initials and No, ~-. ~ t~ And Remit to Street 'Weight (Subject No. Kind of Package, Description of Articles, Special Marks, end Exceptions Packages to Correction) City Zip State Check Column Subject to Section 7 of conditions, if this ship- ment is to be delivered to the consignee without recourse on the consignor, the consignor shall sign the following statement: The carrier shall not make delivery of this shipment without payment of freight and all other lawful charges.. (Signature of consignor.) C. O. D. Charges to be Paid by [] Shipper [] Consignee If charges are to be prepaid, write or stamp here, "To be Prepaid." Received $ to apply in prepayment of the charges on the property described hereon. Agent or Cashier Fer (The signature hem acknowledge~ only the amount prepaid,) Charges Advanced: '$ t ~The fibre containers used for this shipment conform to the specifications set forth in the box maker's certificate thereon, and all other requirements of Rule 41 of the Uniform Freight Classification and Rule 5 of the National Motor Freight Classification." , Shipper's imprint in lieu of stamp; not a par[ f hill of lading approved by the Interstate ~ommerce Commission. ~If the shipment moves between two ports by a carrier by water,, the law requires, t~at th? bill .o~ lading shall state whether it is carrier's or shipper's weight. NOTE -- Where the rate is dependent on value, shippers are required to state specifically tn writing the agreed or declared value of the property. The agl~eed or declared value of the property ts hereby specifically staged by the shipper ge be not exceeding Permanent post-office address of shipper, ('~::~ t--~-(' ~ ?.~( ~ ~'"~ (nt,' (*~~~']'~ pe' ~:~ Agent must detach and retain Shipper, Per. ~_ .';,~.-~,' -- --~..~- ~ this Shipping Order and must sign ...." ~ ! the Original Bill of~ding. ~ .^' v~-, ~t '/.._ r,.: ~_i,, (~L~ ~z:~?,.~. ~ ~ ~ THIS SHIPPING ORDER must be legibly filled in, in Ink, in Indelible Pencil, or in ] Carbon, and retained by the Agent. Shipper's No. Carrier's Name: ~ '~:~ (?'~"Y' t--"t~ '"~'-' ¢"" ~ 3(' RECEIVED, subject to the classificatio~'~ and ~r[ffs'in effec'{'~n the da~ of t~ i~sue o~'~his Bill of lading, Carrier's No. I ~ t .C',t.¢;tC;t - C-')t at ~.~,( t~,.(.~t,, I--~, (Date), ~9_____FROM the property d~scribe~d below, in apparent good order except as noted (contents and condition of contents of packages unknown) marked, consigned-'Ta'nd ~e~ a-~show~ beloW, which s~ald company (the word company being understood throughout this contract as mean ng any person or corporat on in possess on of the property under the contract) agrees to carry to ts usual p ace of delivery at said destination ff on its own railroad, water ne, h ghway route or routes~ or within the territory of its highway operations, otherwise to deliver to another carrier on the route to said destination. It is mutually agreed as 'to each carrier of ail or any of said property over ali or any portion of said route to destination, and as to each party ~t any time interested in all or any of said property that every service to be performed he~unffer s~all ~e subject to all the terms and conditions of the Uniform Domestic'Straight Bill of Lading set forth [1) in the Uniform Freight Classification in effect on the date hereof, ~f this i~ a rail or rail-watsr shipment, or (2) in the applicable motor carrier classification or tariff if this is a motor carrier shipment. Shipper hereby certifies that he is familiar with all the terms and conditions of the said bill of tadlag, including those on the back thereof, set forth in the classification or tariff which governs the transportation of this shipment, andthe said terms and conditions are hereby agreed to by the shipper and accepted for hiraseif and his assigns. · (Mail or street address for purposes of notification only,) Consigned TO ~ (t>f¥'t-~- T',~l~.~ ~ ~t~ On Collect on Oeli~er~, ~hip~ment's~T~T~ett~ "C~D'~ust a~pe'ar b-~e ore consig~nee'~ n~mme o'~r s otherwise provided in Item 430, Sec. 1. Route Delivering Carrier · .:~' Collect on Delivery $ Stre~" Destination ! -~'% ~_ ~ ~' (~. C~w'~ ~ Street (~ ¢~--,,;._£('~. rz ~ , ~ ~% City County I ...... ~ State / '~ Zip Delivery . ~ : Address~ ~ ~ t /~ f',~. ~ ~:~f y~ (~To ~ filled in only when shipper desires and'go~nCn~ta~ pm~ fo~ d~ry~e~)~ ' ~ ~ Car or Vehicle initials and No. %- 4 -~ And Remit to No. H.M / Kind of Package, Des~iption of Articles, Special Marks, and Exceptions 'Weight (Subject I Class Packages I to Correction) or Rate City State Check Column The agreed or declared value of the property is hereby specifically stated by the shipper to be not exceeding per Permanent post-office address of shipper, Sub)ect to Section 7 of conditions, if this ship- ment is to be delivered to the consignee without recourse on the consignor, the consignor shall sign the following statement: The carrier shall not make delivery of this shipment without payment of freight and all other lawful charges. (Signature of consignor.) C. O. D. Charges to be Paid by [] Shipper [] Consignee If charges areto be prepaid, write or stamp here, `Tobe Prepaid.' Receiyed $ to apply in prepayment of the charge~ on the property described hereon. Agent or Cashier Per · (The signature here ~knowledges onty the amount prepaid.) ' Chsrges Advanced: $ t 'The fibre containers used for this shipment conform to the specifications set forth in the box maker's certificate thereon, and all other reqalrements of Rule 41 of the Uniform Freight Classification and Rule 5 qf the National Motor Freight Classification.' Shipper's imprint in lieu of stamp; not a part bill of lading approved by the Interstate mmerce Commission. S,. ~0_~ C~'~ ~"'~ (~'"'"' ~'~ ~ Agent must detach and retain topper, ~ ~ J ~ ~~ · this Shipping Order and must sign b the Original Bill of Lading. '. ·: 1.- . - - ' ~ ....... - :~..:.~:. (::::::~?q:'.:..:.:.~}~:~:~L · . THE PEPSI BOTTLIN I ROUP September 9, 1999 /k~_~ To: Howard Wines From: Chad Buechel I_ - Re: Production Plant Closure ---I Howard, This letter is to inform you, that as of October 15, 1999, Pepsi Bottling Group will no longer operate a production facility at our Bakersfield, located at 215 E. 21st St.. This will eliminate the need for 'us to store, or use, Anhydrous Ammonia in our can & bottle cooling processes. We will coordinate, after October 15, 1999, the draining and disposal of the ammonia .from our systems......This will eliminate all storage and use of Anhydrous Amn}onia'at ',o~!~ facilitY. We 'uiiii;'hbwever, continue the distribution portion of our busine~ Within' Bakersfield and it will remain at its current location, also at 215 E. 21 st St.i: i ~vili Conth~i":~veral days prior to the disposal process to communicate our specific plans to you. Although we will not have the need to see you on as regular of a basis as we have, we at Pepsi would like to express our appreciation for your services and extra efforts in helping our facility, and community, remain as safe as possible. As always, if you have any questions or comments, please feel free to contact me at 635-1188. Sincerely, Chad Buechel CC: Steve Lohgfield ' ' . .... · ~.'i ...... '. 09/17/99' FRI 14:39 FAX 6616351184 PEPSI BAKERSFIELD WRHS ~]001 September 9, 1999 To: Howard Wines From: Chad Buechel Re: Production Plant Closure Howard, This letter is to inform you, that as of October 15, 1999, Pepsi Bottling Group will no longer operate a production facility at oar Bakersfield, located at 215 E. 2P' St.. This will eliminate the need for us to store, or uso, Anhydrous Ammonia in our can & bottle cooling processes. We will coOrdinate, after October 15, 1999, the draining and disposal .. of the ammonia from our systems. This will eliminate all storage and use of Anhydrous Ammonia at our facihty. We will, however, continue the dislribution portion of our business within Bakersfield and it will remain at its current location, also at 215 E. St.. I will contact several days prior to the disposal process to communicate our specific plans to you. Although we will not have the need to see you on as regttlar of a basis as we have, we at Pepsi would like to express our appreciation for your services and extra efforts in helping our facility, and community, remain as safe as possible. As always, if you have any questions or comments, please feel free to contact me at 635-1 Sincerely, Chad Bueehel CC: Steve Longfield Joe Fonseea' Hal Anger (City of Bakersfield) File B A K E RSP I E L D FIRE DEPARTMENT FAX Transmittal TO: ~._ t,f- COMPANY: '~C''~p~ {' FAX No: FROM: ~~~ Office of Environmental Se~ices F~ No. (805} 326-0576 · Bua No. (805} 326-3979 1715 Che~ter Ave. · B~ersfield, CA 93301 8001.12.3.4 Construction. Construction .mji~erials for hazard- ous materials carts~]~ tracks shall be compatlt~l~ with the material -~ls transported. The cart or track shall be:0f subStantial c0nstmciion~ io- 8001.12.3.5 Spill'contro. l. Carts .a. nd tracks transporti.ng.liquids., .3. shall be capable of contmning a spill. frb'm the largest S~ngie c0n2 tainer transported. "-' 8001.12.3.6 Attendance' Carts and. trucks, used to transport materials shallnot obstruct 'or be left unattended within any part.of id, 8001.'12.3.7 Incompatible materialS. Incompatible. materials shall not be transported on the same cart or track. he 8001.13 Facility Closure. ets 8001.13.1 Temporarily out-of-serVice facilities. Facilities ~ which are temporarily out of service shall continue to maintain a ~it permit, and-be monitored and inspected. ~ 8001.13.2 Permanently out-of-Service facilities. Facilities for an,~which a permit is not kept current or. is not monitored and i inspected on a regular basis shall be deemed to be permanently ~ , out of service and shall be closed in accordance' with .Sec- 'as i :e 8001.13.3 Plan. The permit holder or applicant shall submit.. a plan to the fire department to terminat~ storage, dispensing, hah, dling or use of hazardous materials at least 30 days prior to facilitY n- closure. The plan shall 'demonstrate that hazardous materials rs which were stored,, dispensed, handled or used in the facility hav,:,e..,. ce been' transported, disPOsed of or reused in a manner that eliminate,,sl... re the need fOr further maintenance and any threat to public health' and safetY. Such plan shall be submittedin accordance with re 8001.14 Retail and Wholesale Storage and Display. . th 8001.14.1 General. The aggregate quantity of nonflammhbi :s solid and nonfl.ammable or noncombustible liquid hazardous ma~ ~r tefials and health hazard gases within a sin~le'control area'of a~ 09/01/99 16:02 ~661 326 0576 BFD HAZ MAT DIV ~001 *** ACTIVITY REPORT TRANSMISSION OK TX/RX NO. 2889 CONNECTION TEL 6351184 CONNECTION ID PEPSI BAKERSFIEL START TIME 09/01 16:01 USAGE TIME 01'14 PAGES 2 RESULT OK I also wish to receive the items 3, and 4a & b. following services (for an extra · Print your name and address on the reverse of this form so that we can fee): return this card to you. · Attach this form to the front of the mailpiece, or on the back if space 1. [] Addressee's Address dues not permit. · Write "Return Receipt Requested" on the maiipiece below the article number .... 2. [] Restricted Delivery · The Return Receipt will show to whom the article was delivered and the date ,.delivered. Consult postmaster for fee. 3. Article Addressed to: .... P 024 368 605 ~ ,JOE FOI~SECA I~AGER ~. PEPST CO[~A BOCCI, linG cO~_-'~I-~ .... 4b. Servide~¥ype [] Registered [] Ins'ure'd ~,. 215 E 2[ST STREET ~Certified [] COD BAKERS~IEI.~ CA 93305 [] Express Mail [] Re~rn Re'ceipt for ,1 Merchandise 7. Date of Deliver,v ~ r and fee is paid) 5, S'g~ue ( de ;) (Agent) >' PS Form 381 1, December 1991 WU.S. GPO: 1~g3--352-714 DOMESTIC RETURN RECEIPT UNITED STATES POSTAL SERVICE ~ Official Business ~.,~..~ ~c,~ ~/~ .... PENALTY ,FO USE TO AVOID OF POSTAGE, -~. Print your name, address and ZIP Code BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Avenue, Suite 300 Bakersfield, CA '93301 P 024 368 605 -Recei .~ ~- Certified Ma~ . No Insurance Coverage Provided: ~ 'Do not use for International Mail (Se· Reverse) se"t~OE FOI~SECA [qANACER Str"e~af§"Or- 2~ST S~.~E~ P.O. State end ZIP Code ~AKERSFIELD CA 93305 Postage $ .3 2 Certified Fee ~ 1.10 Special Delivery Fee Restricted Derwery Fee Return Receipt Showing I. 10 to Whom & Date Delivered Return Receipt Showing to Whom, Date, and Addressec's Address TOTAL Postage 2.5 2 Postmark or Date June 2l, 1999 Mr. Joe Fonseca, Manager Pepsi Cola Bottling Company 215 E. 21 st Street Bakersfield, CA 93305 FIRE CHIEF ~o~ ~a~ZE CERTIFIED MAIL ADMINISTRATIVE SERVICES 2101 'H' Street EXEMPTION NOTICE Bakersfield, CA 93301 vo,cE (805)326-3941 CAL ARP RISK MANAGEMENT PLAN FAX (805) 395.1349 SUPPRESSION SERVICES Dear Mr. Fonseca: 2101 'H' Street Bakersfield, CA 93301 VOICE (805) 326-3941 Our records indicate that your facility has eliminated or otherwise FAX (805) 395-1349 reduced the amount of a regulated substance below the threshold quantity PREVENllO. SERVICES for the material. You will not be required to submit a Risk Management 1715 Chester Ave. Plan (RMP) nor comply with the California Accidental Release Program Bakersfield, CA 93301 VOICE (805) 326-3951 (Cai ARP) at this time. FAX (805) 326-0576 ENVIRONMENTAL SERVICES You will, however be required to comply with both Cai ARP and 1715 C~oster ^,,e. submit a RMP prior to the introduction of any regulated substance above Bakersfield, CA 93301 VOICE (805) 326-3979 the threshold quantity at your site. In addition, you will still be required to FAX (805) 326-,0576 comply with all codes and regulations for the safe storage and handling of TRAINING DIVISION hazardous materials in general, and the general duty clause for chemical 5042 Victor Ave. accident prevention, in particular. A fact sheet is attached for your Bakersfield, CA 93308 VOICE (805) 399-4697 reference. FAX (805) 399-5763 If you have any questions regarding this exemption, please call me at (661) 326-3979. Sincerely, Howard H. Wines, III Hazardous Materials Specialist Office of Environmental Services HHW/dm attachment THE PEPSI BOTTLING'I RO.UP June 4, 1999 To: Howard Wines From: Chad Buechel Re: Quantification of Ammonia Level for Process System Howard, This letter is to clarify some questions as to the level of ammonia in the systems at our production facility. We have in fact pumped our entire system down to contain all of the liquid in to the receiver on each of our systems. The level of liquid in each system is approximately 350 lbs.. We will be following up with flagging the tanks so that a mathematical calculation will not be necessary to determine the level of the tank. I will follow up with more information as to the completion of the indicators on both of our systems. We have also completed the final installation of the plumbing from our blow- offs to the 1,000-gallon water tank located in the alley area near the CO2 tank. If you should have any questions, or would like to visit to review the work, please feel free to call me at your convenience. Thank you, Chad Buechel CC: Joe Fonseca File \ RECORD OF TELEPHONE CONVERSATION Location: ~?~-'~ ~--' ~- ~ ~D# Business N~rne: ~>~-~ ~ Con~ N~e: ~~ ~ ~ ~ A ~ Busin~ Phone: ~' ~ 2 7. ~ ~ F~: Insp~or's N~e: ~ Type of C~I: In.ming [ ] .O~going [ ] R~m~ ~ Time Required to Complete Activity # Min: ~I.SENDER: Complete items 1 and/or-~or additional services. I also to receive the · Completp items 3, and ~b. following ices (for an extra · Print your name and ad~'on the reverse of this form so that we can fee): return this card to you, · Attach this form to the front of the mailpiece, or on the b'~ackr~f'spa~e 1. [] Addressee's Address does not permit. · Write "Return Receipt Requested" on the mailpiece below the article number. 2. [] Restricted Delivery · The Return ReCeipt will show to whom the article was delivered and the date delivered. 3. Article Addressed to: ° P 024 368 599 JOE. EONSECA Type PEPSI CO[LA_ BOTTLING CO [] Registered [] Insured 215-'~ST 21ST ~KERSFIELD CA 93305 [] Express Mail [] Return Receipt for ~n~e (~ / Merchandise ~ and fee is paid) 6. Signature (Agent) PS Form 3811, December 1991 ~U.S. GPO:l~3--352-714 DOMESTIC RETURN RECEIPT Official Business PENALTY FOR PRIVATE i' USE TO AVOID PAYMENT OF P~OSTAGE, $300 Print your name, address and ZIP Code here · · BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Avenue, Suite 300 Bakersfield, CA 93301 Iii,,,,,,11,1,1,,,I,1,,,!!11,,,,,,11,1,1, J,l,~ II,l,,,,ll,,,ll,ll,,,,,,l{,I,,l} P 024 '368 599 Receipt for:~ · Certified I~'ai!~- No Insurance Coverage Provided ~.~ff~ Do not use for Internattonal Marl (See Reverse) ' ~ se~6~E ' FONSECA P.O State and ZiP Code 2'15 E 21ST ST 05 ~osta~e $ · 325 Certified Fee 1.10 Specie~ Delivery Fee Restricted Delivery Fee Return Receipt Showing 1.10 tO Whom & Date Delivered Return Receipt Showing to Whom, Date, and Addressee's Address TOTAL Postage &~ees $ 2.52 Postmark or Date · May 24, 1999 Joe Fonseca Pepsi Cola Bottling Company 215 East 21 st Street Bakersfield, CA 93305 CERTIFIED MAIL FIRE CHIEF RON FRAZE ~O~.,.,STeAmE SE.~CES FINAL 30 DAY NOTICE 2101 'H' Street Bake~ne~d, C^ 93301 CALARP RISK MANAGEMENT PLAN & VOICE (805) 326-3941 FAX (805)39s-1349 PREVENTION PROGRAM REQUIRED FOR su...Ess,o, sE.vico SUBMISSION &. IMPLEMENTATION PRIOR TO 2101 'H" Street Bakersfield,CA 93301 'JUNE 2 1, 1 999 VOICE (805) 326-3941 FAX (805) 395-1349 Dear Mr. Fonscca: PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 The intent of this letter is to inform you of the rapidly approaching VOICE (805) 326-3951 FAX (805) 326-0576 deadline for complying with the California Accidental Release Program (CaIARP) including submission of the required Risk Management Plan ENVIRONMENTAL SERVICES and implementation of the appropriate Prevention Program prior to 1715 Chester Ave. Bakersfield, CA 93301 June 21, 1999. vOICE (805) 326-3979 FAX (805) 326-0576 Our records indicate that your facility is subject thc CalARP TRAINING DIVISION requirements. By this time, you should have already cOmpleted the 5642 Victor Ave. Bakersfield, CA 93308 Hazard Review or Process Hazard Analysis, the Off-Site Consequence VOICE (805) 399-4697 FAX (805) 399-5763 Analysis, and have entered the necessary data into your Risk Management Plan (RMP) for submission to this office and possibly the United States Environmental Protection Agency (if also subject to federal regulations).' If you have not yet done so, or have any questions regarding the necessary level of coordination between your facility and our office concerning CalARP, please call me immediately at 661-326-3979. Sincerely, Howard H. Wines, III Hazardous Materials Specialist Office of Environmental Services ,SENDER:. , Complete items 1 and/,~i~, for additional services. I also wish to receive the · Complete items 3, a~& b. followin~rvices (for an extra · Print your name and ~ss on the reverse of this form so that we can return this card to you. ~.~-~ 4- fee): ~ Attach this form to the front of the mailpiece, or on {he I~ack if space 1, [] Addressee's Address does not permit. · Write "Return Receipt Requested"on the mailpiece below the articl .... bet. 2. [] Restricted riel;var- · The Return Receipt will show to whom the article was delivered and the date ~" ~ delivered. Consult postmaster for fee. 3. Article Addressed to: 4a. Article Number P 024 368 423 JOE FONSECA I~JkNAGER 4b. Service Type PEPSI CO]J[ [] Registered [] Insured 215 E 21ST STt~.ET II'Certified [] COD BAKERSFIEL]) CA 93305 [] Express Mail [] Return Receipt for Merchandise 7. DateofD. eliyery /~. 5. Sig~a~ure,~Addressee) t " 8. Addressee's Address (Only if requested 6.~SiJ~~.nt )~ ~...~, and fee is paid) PS Form 3811, December 1991 *U.S. GPO: 1993--352-714 DOMESTIC RETURN RECEIPT UNITED STATES ,L SERVICE Official Business PENALTY FOR PRIVATE USE TO AVOID PAYMENT OF POSTAGE, $300 Print your name, address and ZIP Code here · 'BAKERSFIELD FIRE DEPARTMENT ~ OFFICF OF ENVI~I~y,!,_~'I~AL SERVICES ~ 716 OI wester A~.~n~ ~ ~lite'~300 _- I~ake.-'~ield, CA(~3,~01 ~- P 024 368 423 Receipt for: Certified' M~ilI ' ~ . No Insurance Coverage Provided ~.~--9 .Do not use for International Mail (See Reverse) se~t~OE FONSECA S,re~,~ co~ ~.o..~ ~.~,~ s~ Ce~ified Fee 1.~0 Special Deliver. Fee Restricted Delivery Fee Return Receipt Showing ]- · ]- 0 to Whom & Date Oetivered Return Receipt Showing to Whom, Date, and Addressee's Address· . TOTAL Postage &~, $. 2.52 Postmark or Date FII~ E. April 20, 1999 Joe Fonseca Manager Pepsi Cola Bottling Company 215 E 21 st Street Bakersfield CA 93305 ' FIRI: CHIEF CERTIFIED MAIL RON FRAZE ADMINISTRATIVE SERVICES 2101 'H' Street ~kers.e,d. c,~ 933o, 60 DAY NOTICE vo,c~ (~05)32~-3~41 F,x (505)39s-1~49 CALARP RISK MANAGEMENT PLAN & PREVENTION PROGRAM REQUIRED FOR SUPPRESSION SERVICES 21Ol '.' Strut SUBMISSION & IMPLEMENTATION PRIOR TO Bakersfield, CA 93301 voice 18o5) F,x (805)39s-1~49 JUNE 2 1, 1999 PR~vEgnon SEmnCES Dear Mr. Fonseca: 1715 Chester Ave. ~kemfield, CA 93301 vOiCE (sos) 32~3~Sl F~ (S0S)32S~SZS . The intent of this letter is to info~ you of the rapidly approaching deadline for complying with the California Accidental Release Program e~aonaem~ s~a~c~s (CalAn) including submission of the required Risk Management Plan 1715 Chester Ave. S~e=ne~d. CA 9330~ and implementation of the appropriate Prevention Program prior to VOICE (S05) 32~3S79 ~ (SOS) 32~SZS June 21, 1999. x~n~na o~s~on Our records indicate that your facility is subject the CalA~ 5~2 ~ctor Ave. ~k~ne~a. cA 9~os requirements. By this time, you should have already compteted the vOiCE (sos) F~ (S0S).39~STS3 Hazard Review or Process Hazard Analysis, the Off-Site Consequence Analysis,. and have entered the necessa~ data into your Risk Management Plan (~P) for submission to this office and possibly the United States Environmental Protection Agency (if also subject to federal regulations). If you have not yet done so, or have any questions regarding the necessa~ level of coordination between your facility and our office conceding CalAn, please call me immediately at 661-326-3979. Sincerely, Howard H. Wines, III Hazardous Materials Specialist Office of Environmental Services ND SE ER: ' .* Complete items 1 and/a~r, fOr additional services. I aiso~,,jsh to receive the ~ Comptete i~ems 3, an~ b. · followintvices (for an extra Print your name and a~s on the reverse of this Rrm so. th~ we can fee): '~ return this card to you. · Attach this form to the front of the mailpiece, or on the back if space 1. [] Addressee's Address does not permit, · Write "Return Receipt Requested" on the mailpiece below the article number. 2. [] Restricted Delivery · The Return Receipt will show to whom the article was delivered and the date delivered. Consult postmaster for fee. 3. ArticLe Addressed to: 4a. Article Number P 024 368 520 JOE FONSECA I~AGER 4b. Service Type PEPSI COIJ~ BOTTLING CO [] Registered [] Insured 215 EAST 21ST STREET I~ Certified [] COD BAKERSFIELD CA 93305 [] Express Mail [] Return Receipt for Merchandise 7. Date of ,eljfvery 5. Signature~(Addressee) 8. Addr 's dress (Only if requested ~ and fed is paid) 6. Signature IAgent) PS Form 381 1, December 1991 ~u.s. GPO' 1993--352-714 DOMESTIC RETURN RECEIPT UNITED STATES SERVICE ~~~ Official Business ~, I ~? ~ c,.,~ USE TO ~~ OF P~AGE. $30n Print your name, address and ZIP Code here BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Avenue, Suite 300 Bakersfield, CA 93301 II,i,,,,Ih,,ll,lh,,,,,tl,l,,ll IIl'"'"ll'l'h"hi'"llll'"'"lhi'h'l'l'll P 024 368 520' Receipt for Certified Mail mm No Insur~_e.,Cov~erage Provided ~i1~ Do not use for Ifit-emational Mail (See Reverse) Sent to JOE FoNSECA 'MANAGER Street and No. 215 EAST 21ST S~ P:O., State and ZIP Code BAKERSFIELD CA 93305 .o~,,ge $ .3 2 Certified Fee 1.10 Special Delivery Fee " Restricted Delivery Fee Return Receipt Showing 1 o 10 to Whom & Date Delivered Return Receipt Showing to Whom, Date, and Addressee's Address TOTAL Postage &~.a $ 2.52 Postmark or Date March 29, 1999 Joe Fonseca, Manager Pepsi Cola Bottling Company 215 E. 21 st Street Bakersfield, CA 93305 CERTIFIED MAIL FIRE CHIEF Ro. ~R^zE 90 DAY NOTICE JkDMINISTRATIVE SERVICES CalARP RISK MANAGEMENT PLAN & 2101 'H' Street Bakers.e,d, CA 93301 PREVENTION PROGRAM REQUIRED FOR vo,cE (808)326`3941 Fax (805)39~-1349 SUBMISSION & IMPLEMENTATION PRIOR TO su...~ss,o, sE.VIc~s JUNE 21, 1999 2101 'H' Street Bakersfield, CA 93301 VOICE (805) 326-3941 FAX (805) 395-1349 Deaf Mr. Fonseca: PREVENTION SERVICES The intent of this letter is to inform you of the necessary deadlines 1715 Chester Ave. Bakersfield, CA 93301 for complying with the California Accidental Release Program (CalARP) VOICE (805) 326-3951 FAX (805)326`0576 including submission of the required Risk Management Plan and implementation of thc appropriate Prevention Program prior to June 21, ENVIRONMENTAL SERVICES 1999. 1715 Chester Ave. Bakersfield, CA 93301 VOICE (805) 326-3979 FAX (805) 326-0576 Our records indicate that your facility was previously notified of these requirements by Certified Mail dated June 17, 1998. At this time, T~unlnG mvis~o, you should have already coordinated with this office on the method of 5642 Victor Ave. Bakersfield, CA 93308 Hazard Review or Process Hazard Analysis to be conducted, the VOICE (805) 399-4697 FAX (805) 399-5763 appropriate Prevention Program level to be implemented and the Management System employed at your facility to oversee all such CalARP requirements. If you have not yet done so, or have any questions regarding the necessary level of coordination between your facility and our office concerning CalARP, please call me immediately at 661-326-3979. Sincerely, Howard H. Wines, III Hazardous Materials Specialist Office of Environmental Services HHW/dm December 16, 1998 Joe Fonseca, Manager Pepsi Cola Bottling Company 215 E. 21 '~ Street Bakersfield, CA 93305 F,a~ cS~EF RISK MANAGEMENT WORKSHOP FOR INDUSTRY RON FRAZE ADMINISTRATIVE SERVICES JANUARY 7, 1999, 9:00 A.M. 2101 'H" Street Bakersfield, CA 93301 OLIVE DRIVE FIRE TRAINING FACILITY VOICE (805) 326-3941 FAX (805) 395-1349 Dear Mr. Fonseca: SUPPRESSION SERVICES 2101 'H' Street Bakersfield, CA 93301 A workshop conducted by the Governor's Office of Emergency Services VOICE (805) 326-3941 regarding the new California Accidental Release Prevention (CalARP) and FAX (8O5) 395-1349 associated Risk Management Plan programs will be held in Bakersfield on PREVENTION SERVICES Thursday, January 7, 1999 at 9:00 a.m. at the Olive Drive Fire Training Facility 1715 Chester Ave. located at 5642 Victor Street. Bakersfield, CA 93301 VOICE (805) 326-3951 FAX (805) 326-0576 You have been previously notified by this Office that your facility is likely to be subject to the new CalARP requirements, including the EI,~qRONMENTAL SERVICES implementation of a specified Prevention Program and submission of a Risk 1715 Chester Ave. Bakersfield, CA 93301 Management Plan on or before June 21, 1999. This workshop should help VOICE (805) 326-3979 FAX (805) 326-0576 answer any questions you may have. TRAINING DIVISION A letter of invitation, agenda, Request for Comments Letter, and the text 5642 Victor Ave. of the CaiARP regulations are enclosed. You may wish to familiarize yourself Bakersfield, CA 93308 VOICE (O05) 390-4697 with the regulations and bring them along to the workshop for your reference. A FAX (805) 399-5763 map of the workshop location and surrounding restaurants is also attached. Please make every effort to attend this important event. Sincerely, Howard H: Wines, III Hazardous Materials Specialist Office of Environmental Services HHW/dm attachment enclosures · Complete items I and/or 2 for additional services. I also wish to receJ~ · Complete items 3, and 4a & b. following services (for · Print your name and address on the reverse of this form so that we can fee): return this card to you. · Attach this form to the front of the mailpiece, or on the back if space 1. [] Addressee's Address does not permit. · Write "Return Receipt Requested" on the mailpiece below the article number. 2. Restricted Delivery · The Return Receipt will show to whom the article was delivered and the date delivered. Consult postmaster for fee. 3. Article Addressed to: 4a. Article Number JOE FONSECA MANAGER P 024 368 536 PEPSI COlA BOT~LING CONPANY 4b. Service Type 215 E 21S~C STREET [] Registered [] Insured .. BAKERSFIELD CA 93305 [~ Certified [] COD [] Express Mail [] Return Rec~eipt for Merchandise 7. Date of Delivery 8. Addressee's Address (Only if requested and fee is paid) 6. Signature (Agent) PS Form 3811, December 1991 wU.S. OPO:199~--352-714 DOMESTIC RETURN R STATES POSTAL SERVICE Official Business PENALTY FOR PRIVATE USE TO AVOID PAYMENT OF POSTAGE, $300 Print your name, address and ZIP Code here · CI~ OF BAKERSFIELD FIRE DEPT OFFICE OF ENVIROI~[ENTAL SERVICES 1715 CEESTER AVENUE St~IE 300 BAKERSFIELD CA 93301 P 024 368 536 Receil~for Certffie-d 'Ma~. No Insurance Coverage Provided ~ Do not. use, for International Maid (See Reversel s~ FONS~CA ~AC~R ~1~"~°'2 lS~ s~ ~~ CA 93305 Certified Fee 1.10 Special Oel~e~y Fee Res~Jcted Oelivew ~e Return Receipt Showing ~ '0 ~om & Date Deli~red 1.10 Return Receipt Showing tO Whom, Date, and Address~'s Address TOTAL Postage · F.~ ~ 2.52' Postmark Date BAKERSFIELD FIRE DEPARTMENT June 17, 1998 Joe Fonseca, Manager FiRE CHIEF Pepsi Cola Bottling Company MICHAEL R. KELLY 215 E. 21" Street Bakersfield, CA 93305 ADMINISTRATIVE SERVICES 2101 'H' Street - Bak~ei~fleld, CA 93301 CERTIFIED MAIL (805) 326-3941 FAX (80,5)395-1349 NOTICE OF RISK MANAGEMENT PLAN (RMP) REQUIRED BY JUNE 21, 1999 ~PPIIESSlON SERVICES 2101 'H" Street Bakersfield, CA 93301 Dear Mr. Fonseca: (805) 326-3941 FAX (805)395-1349 Your facility has been identified by this office as a probable candidate to be subject to the new California Accidental Release Program (CalARP), which will involve among many other PI~EVENTION SERVICES requirements, the submission of a Risk Management Plan to this office, and also to the United 1715 Chester Ave. ' Bakersfield, CA 93301 States Environmental Protection Agency (USEPA) in many cases, on or before June 21, 1999. (805) 326-3951 FAX (805)326-0576 The CalARP regulations are a merging of the federal and state risk management prevention programs for accidental release prevention of several hundred listed flammable or ENVII~NMENTAI. SERVICES toxic substances (e.g.: ammonia, chlorine, propane, etc.) which pose the greatest risk of causing 1715 Chester Ave. Bakersfield, CA 93301 death, injury, or seriously affecting human health or the environment if accidentally released. (805) 326-3979 FAX (805)326-0576 The rule requires certain facilities to develop and implement an integrated system to identify hazards and manage risks associated with these regulated substances. Since your facility II~NING DIVISION appears to be subject to this rule, you will be required to analyze worst-case releases, document a 5642 Victor Street fix)e-year history of serious accidents, coordinate with local emergency responders, develop and Bakersfield, CA 93,308 (805) 399-4697 implement a prevention program that includes, among other steps, identification of hazards, FAX (805)399-5763 written operating procedures, training, maintenance, and accident investigation. If your employees also respond to accidental releases, you must implement an integrated local emergency response program. An informative digest is enclosed for your reference. The text of the regulations, technical assistance, and other information is available from our office by calling me directly at (805) 326-3979. Sincerely, Howard H. Wines, III Hazardous Materials Specialist Office of Environmental Services HHW/dm enclosure ~ I SEE YOU ~ ~ AGAIN ~ ~'~-¢ I'BAOK~CAL[; r---]IWANTSTO'j'-~JWILLCALL~-] WASIN E~'JI.IRGENTE] MAY-12-98 TUE 12:26 PM PEPSI BAKERSFIELD FAX NO, 8063260913 P, O1 Pepsi-Cola Mid-Cai Market Unit 215 Easl 21st Street Bakersfield, CA 93305 FAX Total Number of Pages Z. (includes cover sheet) DATE TO COMPANY FAX NUMBER ~- ~ - OS7 ~ FROM PHONE & E~ ~ 805.63GLI00 F~ NUMBER COMMENTS I"IAY-12-98 TUE 12:26 PI"I PEPSI BAKERSFIELD FAX NO. 8053260913 P, 02 § :r'/Og .. B .ALSYS CALIFORNIA CODE OF RE~ULATI01 'Tim 19 EMERG£NCY RI~.£ASE I~)LLOW-UP NOTICE REi~RTING FO~ c ~1~ ~. ZIs~ ~T~ . B~F~E~ ~E~ D ":" e~ Il 0 ,;* I~G A ~ ' ' :-7 ~ ........... ~ ,.~. ., ;,.-: .... · .: ..... '~'.,. .- ~ ...... ~AnON ';j, I ( : ~ PoTW. ' 5:~' - ' ' ::~ ~ - IZ ' f& ?,=~: $IGNA~RE OF ~T~O PACifY ~PR~T~ ~ DA~ BAKERSFIELD FIRE DEPARTMENT FAX Transmittal TO: ~'J~ COMPANY: ~(~4:~S I FAX No: ~ ~ - O~ FROM: ~L--~~ Office of Environmental Services FAX No. (805) 326-0576 · Bus No. (805) 326-3979 1715 Chester Ave. · Bakersfield, CA 93301 Title 19 Office of Emergency Services § 2705 EMERGENCY RELEASE FOLLOW-UP NOTICE REPORTING FORM INSTRUCTIONS GENERAL INFORMATION: Chapter 6.95 of Div is ion 20 or' the Calit'ornia Health and Sat'ety Code requ ires that written emergency release l'ollow-up notices pre- pared pursuant to 42 U.S.C. § 11004, be submitted using this reporting form. Non-permitted releases of reportable quantities of Ex- tremely Hazardous Substances (listed in 40 CFR 355, appendix A) or of chemicals that require release reporting under section 103(a) of thc Comprehensive Environmental Response, Compensation, and Liability Act of 1980 [42 U.S.C. § 9603(a)] must be reported on the l'orm, as soon as practicable, but no later than 30 days, following a release. The written follow-up report is required in addition to the verbal notit'ication. BASIC INSTRUCTIONS: · The form, when filled out, reports follow-up information required by 42 U.S.C § 11004. Ensure that all information requested by the form is provided as completely as possible. · If the incident involves reportable releases of more than one chemical, prepare one report form for each chemical released. · If the incident involves a series of separate releases of chemical(s) at different times, the releases should be reported on separate reporting forms. .. SPECIFIC INSTRUCTIONS: Block A: Enter the name of the business and the name and phone number of a contact person Who can provide detailed facility infor. mation concerning the release. Block B: Enter the date of the incident and the time thatVerbal notification was made to OES. Tl~e OES control number is PrOvided to the caller by OES at the time verbal notification is made. Enter this control number in the space provided. Block C: Provide information pertaining to the location where the release occurred. Include the street address, the city or community, the county and the zip code. Block D: Provide information concerning the specific'chemical that Was released. Include the chemical or trade name and the Chemi- cal Abstract Service (CAS) number. Check all categories that apply. Provide best available information on quantity, time and dui'ation of the release. . Block E: 'Indicate all actions taken to respond to and contain'the release as specified in 42 U.S.C. § 11004(c). Block F: Check the categories that apply to the health effects that occurred o~could'reS~lt from the release. Provide ~n explanation or description of the effects in the space provided. Use Block H for additional comments/information if necessary tomeet requirements specified in 42 U.S.C. § 1 I004(c). Block G: Include information on the type of medical attention required for exposure to the chemical released. Indicate when'and how this information was made available tO individuals exposed and to medical p,e~nnel, if. appropriate for the incident, as specified in 42 U.S.C. § 11004(c). . ..... .. "... Block H: List any additional pertinent information. Block I: Print or type the name of the facility representative submitting the report. Include the official signature and the date that the lbrm was prepared. .' MAIL THE COMPLETED REPORT TO: Chemical Emergency Planning and Response Commission (CEPRC) Local Emergency Planning Committee (LEPC) Attn: Section 304 Reports 2800 Meadowview Road Sacramento, CA 95832 No'm: Authority cited: Sections 25503. 25503.1 and 25507.1. Heallh and Safety HIS~ORY: Code. Reference: Sections 25503(b)(4). 25503.1, 25507.1,25518 and 25520, 1. New section filed 9--20-90;, operative 10-20-90 (Register 90, No. 45). Health and Safety Code. Page 121 R,~,, 06. ~o,. ~a-~. ~_~0-06 § 2705 BARCI CALIFORNIA CODE OF REGULATI~ 'Title 19 EMERGENCY RELEASE FOLLOW-UP NOTICE REPORTING FORM ( I I INCIDENT MO DAY YR I I TIME I I OES C [ ~ INCIDENT [ I CI~/COMMUNITY [ ~COUNTY ZIP 40 Cm 355, ~PENDIX A ~ UNDER 42 U.S.C. D ~ IPHYSIC~ STA~ COST*ED I PHYSIC~ STA~ RELEASED ~ IQU~RELEASED ~ SOLID ~ LIQUID ~ GAS ~ SOLID ~ LIQUID ~ GAS ' ' ' ~ I EN ~ONMENT~ CONTAM~A~ON } ~ ~ME OF ~LEASE [ I D~A~ON OF ~LEASE ~" A~IONS T~N ~::~:::~ ~OWN OR ~C~A~D ~TH E~C~ (U~ ~e co~en~ ~cfion for additional ~fomafion) ' ~ ~ ACU~ OR IMMEDIA~ ~ ~D~CE ~G~D~G MEDIC~ A~NTION NE~SS~Y FOR E~OSED ~DI~DU~ H ::~::~::::~:~ CO MMEN~ ~DICA~ SE~ON (A~, ~D I~M WI~ COMMENTS OR AD DITION~ INFORM A~ON ~ ~R~FICATION: I hereby ~i~ ~der ~nalty of~w ~at I ~ve ~rsonally exam~ed and I am laminar wi~ ~ ~fo~ation *ubmit~d and beC,ye ~e ~ubmitt~ ~fo~afion is ~e. ac~ra~, and ~mple~. Page 120 05/11/98 07:29 '~805 326 0576 BFD HAZ MAT DIV ~001 *** ACTIVITY REPORT *** TRANSMISSION OK TX/RX NO. 6394 CONNECTION TEL 3260913 CONNECTION ID START TIME 05/1I O7:27 USAGE TIME 02'11 PAGES 3 RESULT OK -'~ MA~ 11 '98 08:35AM OES H(~ SACRAMEMTO P.1/I' ~~ ~' EMERGENCY SERVICES ~~ Ha~a~ou= Me.rials. Spill Repo~ DAT~ 05/1 ~/98 REC~I~ BY: CONTRO~ · T~: 0818 OES- Ben ~n 98-2220 OSPR - '~Cb~ ~uecbel Pcp~J-Cola 1nc 80~-~35-1170 '* ' 2' SU~TANC~ TYPE: ~Ammonia c~po~d] ~. 'DES~ON: ~pment fail~ caused'~i~sion of ~onJa into c~g waar of e~o~ ~wer. ~ater dump~ ~to ~-house indu~i~ &a~ & ~ at on-site ~te pl~t; w~er mixM 10-1~o at w~e p~t; 9t t~er mixed 42-~a~ ~onia ~1~ by 800g~s ofw~r. L~ s~ed ~prox Sa~day ~ound 1200~ ~d ~n~ued ~ t~ 0600~. ~, CONT~ED: ~. WA~R ~OL~D: h. WAT~WAY: ~. a~ INC~ENT'~CA~ON: 215'E~t 21st St ~e~field Kern CounW 93305 ~ . 0 0 Repo~&g P~ ~had Bushel Pepsi-Cola ~c 805-635-1170 ~. 215 ~t 21st St B~rsfield ~ 93305 ~6. ,NO~ICA~0N ~R~TION: '~ O~R ON SCE~: d. O~R N~D: ~ e. ~. AGENt: B~cld ~lre ~ent f. SEC. AGENCY: ~ ~pt t' ' ' ~g~ N~CA~ON LIST: D~ Unit: RW~ Un[~ 5C BAKERSFIELD FIRE DEPARTMENT FAX Transmittal COMPANY: r"'f~-.ps ~ FAX No: ~ '2~ - oc/'~ ~ FROM: ~,,~z~ (.~-)~ $ Office of Environmental Services FAX' No. (805) 326-0576 · Bus No. (805) 326-3979 1715 Chester Ave. · Bakersfield, CA 93301 (3) The contract owne~toperator shall document that each co~[liaCt employee has received and understood the training required by this sectiol~tThe contract owner or operator shall prepare a record which contains the identity of the contract employee, the date of training, and the means used to verify that the employee, understood the training. (4) The contract owner or operator shall assure that each contract employee follows the safety rules of the stationary source including the safe work practices required by Section 2760.3(d). (5) The contract owner or operator shall advise the owner or operator of any unique hazards presented by the contract owner or operator's work, or of any hazards found by the contract owner or operator's work. NOT£: Authority cited: Sections 25531 and 25534.05, Health and Safety Code. Reference: Section 2553 l, Health and Safety Code; and Section 68.87, Part 68, Code of Federal Regulations. Article 7. Emergency Response 2765.1 Applicability. 2765.2 Emergency Response Program. Section 2765.1 Applicability. (a)Except as provided in section (b), the'owner or operator of a stationary source with Program 2 and Program 3 processes shall comply with the requirements of Section 2765.2. (b) The owner or operator of stationary source whose employees will not respond to accidental releases of regulated substances need not comply with Section 2765.2 provided that they ~ meet the following: (1) For stationary sources with any regulated toxic substance held in a process above the threshold quantity, the stationary source is included in the community emergency response plan developed under Section of 11003 of Title 42 of the United States Code (USC); (2) For stationary sources with only regulated flammable substances held in a process above the threshold quantity, the owner or operator has coordinated response actions with the local fire department; and (3) Appropriate mechanisms axe in place to notify emergency responders when there is a need for a response. NOTE: Authority cited: Sections 25531 and 25534.05, Health and Safety Code. Reference: Section 25531, Health and Safety Code; and Section 68.90, Part 68, Code of Federal Regulations. CalARP Regulations 6/30/97 Page 47 Section 2765.2 Emer~hcy Response Program. (a) The owner or operator shall develop and implement an emergency response program for the purpose of protecting public health and the environment. Such program shall include the following elements: (1) An emergency response plan, which shall be maintained at the stationary source and contain at least the following elements: (A) Procedures for infOrming and interfacing with the public and local emergency response agencies about accidental releases, emergency planning, and emergency response; (B) Documentation of proper first-aid and emergency medical treatment necessary to treat accidental human exposures; and (C) Procedures and measures for emergency response after an accidental release of a regulated substance; (2) Procedures for the use of emergency response equipment and for its inspection, testing, and maintenance; (3) Training for all employees in relevant procedures and the Incident Command System; and (4) Procedures to review and update, as appropriate, the emergency response plan to reflect changes at the stationary source and ensure that employees are informed of changes. (b) A written plan that complies with other federal contingency plan regulations or is consistent with the approach in the National Response Team's Integrated Contingency Plan Guidance ("One Plan") and that, among other matters, includes the elements provided in section (a), shall satisfy the requirements of this section if the owner or operator also complies with section (c). (c) The emergency response plan developed under section (a)(1) shall be coordinated with the community emergency response plan developed under Section 11003 of Title 42 of USC. Upon request of the local emergency planning committee or emergency response officials, the owner or operator shall promptly provide to the local emergency response officials information necessary for developing and implementing the community emergency response plan. (d) The owner or operator is not required to meet the business plan requirements if the emergency response plan developed under this section is consistent with the business plan requirements pursuant to Sections 2731 and 2732 of Title 19 of CCR. This does not exempt the owner or operator from requirements which relate to the annual inventory or emergency response planning for hazardous materials which are not regulated substances. CalARP Regulations 6/30/97 Page 48 ion 112 of the Clean Air Act (42 (b) A petition submitted pursuant to subdivision (a) (5) The likelihood of the substance being handled in shall be accompanied by a submission fee, t° be this state. established by the office, in consultation with the Office (6) The accident history of the substance. of Environmental Health Hazard Assessment. The fee shall be in an amount that is sufficient to pay for the (h) Upon receipt of a recommendation made pursu- reasonable costs incurred by the office and the Office of ant to subdivision (f), the office may add or remove a substance or change an existing state threshold quantity Environmental Health Hazard Assessment necessary to carry out' this section. Upon the receipt of the petition as a requirement for this article. and fee, the office shall transmit to the Office of (i) In reviewing a petition under this section, the Environmental Health Hazard Assessment funds suffi-' office shall consider the views of administering agencies cient to pay for the reasonable costs incurred by the .that have indicated support or opposition to the peti- Office of Environmental Health Hazard Assessment to tion. (Added by Stats. 1994, c. 618 (A.B. 3263), § Z carry out this section. Amended by Stats. 1996, c. 715 (S.B. 1889),. § 35.) (c) An owner or operator of a stationary, source shall § 25543.2. Modification of facility which may result in not delay implementation of this article in anticipation significant increase in amount of regulated sub- of.a ruling on a petition to delist a * * * regulated stances handled, or in si~t, nificantly increased risk; substance or to change a state threshold quantity, requirements (d) The office shall notify administering agencies of (a) A * * * stationary source that intends to modify petitions for adding or delisting * * * regulated sub- a facility which may result either in a significant increase stances or for changing * * * state threshold quantities in the amount of * * * regulated substances handled by and shall take comments from * * * administering the facility or in a significantly increased risk in handling .age.ncies on the petitions. All comments shall be * * * a regulated substance, as compared to the responded to in writing, amount of substances and the amount of risk identified (e) The office shall notify the public of petitions for in the facility's RMP relating to the covered process adding or delisting * * * regulated substances or for proposed for modification, shall do all the following, changing * * * state threshold quantities and shall take prior to operating the modified facility: public comment on the petitions. All comments shall (1) Where reasonably possible, notify the administer- be responded to in writing, lng agency in writing of the * * * stationary source's (f)(1) The office shall request the Office of Environ- intent to modify the facility at least five calendar days mental Health Hazard Assessment to review the peti- before implementing any modifications. As part of the tions and make recommendations to the office regard- notification process, the * * * stationary source shall lng the petitions, consult with the administering agency when determining . whether the * * * RMP should be reviewed and (2) Each recommendation made pursuant to para- revised. Where prenotification is not reasonably possi- graph (1) shall be based on current scientific knowledge hie. the * * * stationary source shall provide written and a sound and open scientific review and shall contain notice to the administering agency no later than 48 a finding whether a substance should be added to. or hours following the modification. deleted from. the regulated substance list. or whether the state threshold quantity for a regulated substance (2) Establish procedures to manage the proposed should be revised, modification, which shall be substantially similar to the · · · procedures specified in Section 1910.119 of Title 29 of the Code of Federal Regulations pertaining to process (g) The petition review by the Office of Environmen- safe .ty management, and notify, the administering agency tal Health Hazard Assessment shall take into consider- that the procedures have been established. ation all of the following factors: (b) The * * * stationary source shall revise the (1) The severity of any acute adverse health effect appropriate documents, as required pursuant to subdivi- associated with an accidental release of the substance, sion (al. expeditiously, but not later than 60 days from the date of the facility modification. (Added by Stats. (2) The likelihood of an accidental release of the 1994, c. 618 (A.B. 3263), § 3. Amended by Stats. 1996, c. substance. 715 ~S.B. 1889), § 36. ~ (3) The potential magnitude of human exposure to an accidental release of the substance. § 25543.3. Determinations and regulations; regulat- ed substances list; threshold quantities; deadline (4) The results of other preexisting evaluations of. the substances potential risks which take into account the On or before June 30, 1998, the office, in consultation factors specified in paragraphs (1). (2), and (3), includ- with the Office of Environmental Health Hazard As- lng, but not limited to, studies or research undertaken sessment, shall do all of the following: by, or on behalf of, the'Environmental Protection (a) Review each regulated substance on the list Agency. for the purpose of complying with paragraph (3) established pursuant to subparagraph (B) of paragraph 11/26/97 14:36 8805 3 0576 BFD HAZ MAT DIV ~001 *** ACTIVITY REPORT *** TRANSMISSION OK TX/RX NO. 4249 CONNECTION TEL 3260913 CONNECTION ID START TIME 11/26 14:32 USAGE TIME 03'41 PAGES 4 RESULT OK BAKERSFIELD FIRE DEPARTMENT FAX Transmittal TO: COMPANY: FROM: -- Office of Environmental Services FAX No. (805) 326-0576 · Bus No. (805) 326-3979 1715 Chester Ave. · Bakersfield, CA 93301 : OE$ ..................... calif0-rnia--Accidental Release Prevention Emergency Regulations pursuant to SB 1889 (Health & Safety Code § 25531. to § 25543.3) July 1997 EMERGENCY REGULATIONS GOVERNOR'S OFFICE OF EMERGENCY SERVICES TEXT OF REGULATIONS California Code of Regulations Title -19. Public Safety Division 2. Office of Emergency Services Chapter 4.5 California Accidental Release Prevention (CalARP) Program Detailed Analysis Article 1. General ............................................................................................................... 1 2735.1 Purpose ................................................................................................................ 1 2735.2 Scope ............................................ ~ ...................................................................... 1 2735.3 Definitions ........................................................................................................... 1 2735.4 Applicability ........................................................................................................ 6 2735.5 General Requirements ......................................................................................... 7 2735.6 CalARP Program Management ........................................................................... 9 2735.7 Emergency Information Access .......................................................................... 9 Article 2. Registration ................................ ' ...................................................................... 10 2740.1 CalARP Program Registration .......................................................................... 10 2740.2 Federal Registration .......................................................................................... 11 Article 3. Risk Management Plan Submission Requirements and Components ....... 12 2745.! Submission ............................................ : ...................................................... ~ ..... !2 2745.2 RMP Review Process ........................................................................................ 13 2745.3 ' Executive Summary 15 2745.4 Offsite Consequence Analysis ........................................................................... 15 2745.5 Five-year Accident History ...................................... ' ......................................... 16 2745.6 Program 2 Prevention Program ......................................................................... 16 2745.7 Program 3 Prevention Program ......................................................................... 18 2745.8 Emergency Response Program .......................................................................... 20 2745.9 Certification ....................................................................................................... 20 2745.10 Updates .............................................................................................................. 20 2745.11 Covered Process Modification '. ......................................................................... 22 2745.12 Occupancy Certificate ............................... · ........................................................ 22 CalARP Regulations 6/30/97 Page i Iff Article 4. . Hazard Assessment .......................................................................................... 23 i~' 2750.1 Applicability ...................................................................................................... 23 2750.2 Offsite Consequence Analysis Parameters ........................................................ 23 2750.3 ' Worst-Case Release Scenario Analysis ......................................................... 24 2750.4 Alternative Release Scenario Analysis .............................................................. 27 2750.5 Defining Offsite Impacts to the Population ....................................................... 28 2750.6 .. ._ Defining Offsite Impact. s to the Environment ..... · ...... ..... ....... : .......... ' ......... : ........ 28 2750.'~- Off.site Consequence Analysis Revie~vand Update ..................... i .................... 29 2750.8 Offsite Consequence Analysis Documentation ................................................. 29 ._ . 275.0.9 ......... Five-year Accident. History .............................................................. ;.~::~.. ....... :...-30 Article 5. Program 2 Prevention Program ..................................................................... 30 2755.1 Safety Information ............................................................................................. 31 2755.2 Hazard Review .................................................................................................. 31 2755.3 Operating Procedures ........................................................................................ 32 2755.4 Training ............................................................................................................. 33 2755.5 Maintenance ...................................................................................................... 33 2755.6 Compliance Audits ............................................................................................ 34 2755.7 Incident Investigation ........................................................................................ 34 Article 6. Program 3 Prevention Program ..................................................................... 35 2760.1 Process Safety InfOrmation ......................... i..i ........................................... i ....... 35 2760.2 Process Hazard Analysis ................................................................................... 37 2760.3 ::'--:' · Operating Procedures .~.:.~...: .... 2:...'.' ....... ~.~.~:.~:i..'.~'..~ ...... ' ..... ;.'.: ......... ' ...... ' ......... '..39 ~ -- 2760.4 Training ............................................................................................................. 41 2760.5 Mechanical Integrity .......................................................................................... 41 2760.6 Management of Change ..................................................................................... 43 2760.7 Pre-Starmp Re. view ........................................................................ ~ ................... 43 2760.8 Compliance Audits ............................................................................................ 44 2760.9 Incident Investigation ............................ ';.: .... ~: ................................................... 44 2760.10 .__ Employee Participation ..................................................................................... 45 2760.11" Hot Work Permit ........ ~ ................................... i...' ............................................... 45 2760.12 Contractors ........................................................................................................ 46 Article 7. Emergency Response ....................................................................................... 47 2765.1 Applicability ...................................................................................................... 47 2765.2 Emergency Response Program .......................................................................... 48 Article 8. Regulated Substances for Accidental Release Prevention ........................... 49 2770.1 Purpose .............................................................................................................. 49 2770.2 Threshold Determination ................................................................................... 49 2770.3 Petition Process ................................................................................. . ................ 51 CalARP Regulations 6/30/97 Page ii '~ 2770.4f Exemptions ........................................................................................................ 51 2770.5 List of Substances .............................................................................................. 51 Table 1 Federal Regulated Substances and Threshold Quantities for Accidental Release Prevention ............................................................................................ 53 Table 2 Federal Regulated Flammable Substance List and Threshold Quantities for Accidental Release Prevention .................................................................... 55 Table 3 .... State.Regulated Substances List and Threshold-Quantities for Accidental ....... Release Prevention ............................................................................................ 57 Article 9 ........... Other Requirements ............... 2775.1 Recordkeeping ................................................................................................... 64 2775.2 Availability of Information to the Public .......................................................... 64 2775.3 Permit Content and Air Permitting Authority or OES Requirements ............... 64 ~- 2775.4 Audits ................................................................................................................ 65 2775.5 Inspections ............................................. i ........................................................... 67 Article 10. Dispute Resolution ........................................................................................... 67 2780.1 Local Implementation Standards ....................................................................... 67 2780.2 Administering Agency Performance Standards ................................................ 69 2780.3 Maintenance of Administering Agency Authorization and Reporting .............. 69 2780.4 . _ Coordination with the Unified Program ............................................................ 70 2780.5 Performance Audit Submission ......................................................................... 70 2780.6 Administering Agency Performance Evaluations .................~:.~ ..... :.....~.....:...,..~..71 -. . · . .... '- 2780.7 ":'" OES Authority ...... .~ ....... i-i ..... '....'i'i'. ...... i}} ...... i.i~.} ..... ~i.i.i ....................................... 72 Article 11. Technical Assistance ........................................................................................ 72 2785.1 Technical Assistance ......................................................................................... 72 Appendix A to Title 19, Division 2, Chapter 4, Subchapter 'i'i' Table of Toxic Endpoints ............ 73 CalARI' Rcgulalions 6/30197 Page iii (c) The owner or operator may use checklists, if acceptable to the AA, developed by persons or organizations knowledgeable about the process and equipment as a guide to conducting the review. For processes designed to meet industry standards or federal or state design rules, the. hazard review shall, by inspecting all equipment, determine whether the process is designed, fabricated, and operated in accordance with the applicable standards or rules. (d) The hazard review shall include the consideration of applicable external events, including seismic events. (e) The owner or operator shall document the results of the hazard review and ensure that problems identified are resolved in a timely manner. (f) The hazard review shall be updated at least once every five years. The owner or operator shall also conduct reviews whenever a major change in the process occurs. All issues identified in the hazard review shall be resolved before startup of the changed process. No'r~.: Authority cited: Sections 25531 and 25534.05, Health and Safety Code. Reference: Section 25531, Health and Safety Code; and Section 68.50, Part 68, Code of Federal Regulations. Section 2755.3 Operating Procedures. (a) The owner or operator shall prepare written operating procedures that provide clear instructions or steps for safely conducting activities associated with each covered process consistent with the safety information for that process. Operating procedures or instructions provided by equipment manufacturers or developed by persons or organizations knowledgeable about the process and equipment may be used as a basis for a stationary source's operating procedures. (b) The procedures shall address the following: (1) Initial startup; (2) Normal operations; (3) Temporary operations; (4) Emergency shutdown and operations; (5) Normal shutdown; ~ _.-_ ...... ~ :.__~-- -:-~ .:: ~:-:': .... · (6)Startup following a normal or emergency shutdown or a major change that requires hazard review; (7) Consequences of deviations and steps required to correct or avoid deviations; and CalARP Regulations 6/30/97 Page 32 (8) Equipment inspeOns. (c) The owner or operator shall ensure that the operating procedures are updated, if necessary, whenever a major change occurs and prior to startup of the changed .process. NOTE: .Authority cited: Sections 25531 and 25534.05, Health and Safety Code. Reference: Section 25531, Health and Safety Code; and Section 68.52, Part 68, Code of Federal Regulations. Section 2755.4 Training. (a) The owner or operator shall ensure that each employee presently operating a process, and each employee newly assigned to a covered process has been trained or tested competent in the operating procedures provided in Section 2755.3 that pertain to their duties. For those employees already operating a process on June 21, 1999, the owner or operator may certify in writing that the employee has the required knowledge, skills, and abilities to safely carry out the duties and responsibilities as provided in the operating procedures. (b) Refresher training. Refresher training shall be provided'at least every three years, and more often if necessary, to each employee operating a process to ensure that the employee understands and adheres to the current operating procedures of the process. The owner or operator, in consultation with the employees operating the process, shall determine the appropriate frequency of refresher training.. (c) The owner or operator may use training conducted under federal or state regulations or under industry-specific standards or codes or training conducted by covered process equipment vendors to demonstrate compliance with this section to the extent that the training meets the requirements of this section. (d) The owner or operator shall ensure that operators are trained in any updated or new procedures prior to startup of a process after a major change. NOTE: Authority cited: Sections 25531 and 25534.05, Health and Safety Code. Reference: Section 25531, Health and Safety Code; and Section 68.54, Part 68, Code of Federal Regulations. Section 2755.5 Maintenance. .............. (a)--The owner or operator shall prepare and implement procedures ~to maintainthe on-going mechanical integrity of the process equipment. The owner or operator may use procedures or instructions provided by covered process equipment vendors or procedures in federal or - :'- :":-' ' ..... state regulations or industry codes as the basis for Stationary'source maintenance procedures. (b) The owner or operator shall train or cause to be trained each employee involved in maintaining the on-going mechanical integrity of the process. To ensure that the employee can perform the job tasks in a safe manner, each such employee shall be trained in the CalARP Regulations 6/30/97 Page 33 BAKERSFIELD FIRE DEPARTMENT November 19, 1997 Chad Buechel, Production Supervisor Pepsi Cola Bottling Company 2 15 East 2 1st Street FIRE CHIEF MICHAEL R. KELLY Bakersfield, CA 93305 ADMINISTRA11VE SERVICES 2101 'H' Street Boke~fleld, CA 93301 RE: Certification Training in Ammonia Refrigeration (805) 326-3941 FAX (805) 395-1349 SUPPRf~qSlON SERVICES Dear Mr. Buechel: 2101 'H' Street Bokersfield, CA 93301 . (805) 326-3941 The Kern Chapter of the Refrigerating Engineers and Technicians FAX (805) 395-1349 Association (RETA), in cooperation with San Joaquin Valley College, is offering P~mON SERVICES certification in industrial refrigeration as an added benefit of RETA membership. 1715 Chester Ave. Bakersfield, CA 93301 Classes are held just one night a month (generally the 4th Tuesday at 7:00 PM), (805) 326-3951 throughout the next two years, at the San Joaquin Valley College campus, located FAX (805) 326-0576 at 201 New Stine Road in Bakersfield. ~~v,~o~,a~m,~ s~c~s 1715 Choster Ave. The new California Accidental Release Program regulations, modeled Bakersfield, CA 93801 (8135) 326-3979 after the federal Risk Management Program, will by June 21, 1999, require FAX (805) 326-0576 additional levels of employee training and competency in processes involving TI~INING DBII$1ON ammonia. Training under industry-specific standards may be used to demonstrate fxM2 Victor Street compliance with these new regulations. (Reference: § 2755.4, Title 19, California Bakersfield, CA 93308 (805) 39%4697 Code of Regulations). I will be participating in these classes as well. FAX (8135) 399-5763 The classes will begin on Tuesday, November 25, 1997, at 7:00 PM. Please see the attached newsletter and membership form for more information. Sincerely, Howard H. Wines, III Hazardous Materials Technician Office of Environmental Services HHW/dm attachments The RETA Reader. Kern Chapter, Monthly New~letter NOVEMBER 1997 Volum~ 2, Issue 4 NOVEMBER R E MEETING Nov. 25, 1997 T~A San Joaquin Valley College 7:00 P.M. From The President; From the RETA Industrial Refrigeration Course I text book we will be discussing Chapters 1 and 2 · Lesson 1: Technicians and Refrigeration: The Refrigeration Cycle · Lesson 2: Refrigeration Cycle Factors: Physical Factors Affecting the Refrigeration Cycle The Industrial Refrigeration Course I tcxt can bc purchased at San Joaquin Valley College Book Store. Twenty-five text books have been ordered. To reserve a copy of the text, call Elwin L. Hunt, RETA Kern Chapter President at (805)-834-0126 (San Joaquin Valley College) between 7:00 a.m. and 4:00 p.m, monday through thursday and between 8:00 a.m. and 12:00 noon on fridays. The text will cost $54.00 and can be purchased either before the class begins or at the time of the first class. Otherwise, your text book reservation will be forfeited and be sold on a first come first-served basis. Bring an associate and see what we have to offer. Education is the best IIIJI, I, ETIN iIOllllD investment you'll ever make. · RETA Monthly Meeting Held every fourth Tuesday at San Joaquin Valley College 7:00 pm See you there! · RETA Kern Chapter Incident Command Wo~shop Late February 98 Elwin L. Hunt · For More Inforrnatio~ about RETA President Kern Chapter RETA s~ the RETA Web Site Pa$¢ I C TIFICATION PROGI M Refrigeration plant owners, managers, operators and engineers and refrigeration equipment manufacturers agree on one basic point -- qualified plant operators are vital for the indusl~-y. RETA's certification program is directed toward meeting the need of providing the industry with qualified operators through continued education and training using RETA materials. The RETA Certification Program is based on on-the-job practical experience for two or more years enhanced with a systematic approach, to ~raining through the RETA Industrial Refrigeration books. The exam is proctored and timed. The program helps individuals improve their technical skills and provides employers with a helpful benchmark for reviewing job applicants and current employees. While not an engineering degree or state regulatory license, certification does establish that the person certified has met RETA's experience, education, skill level and test requirements. The program's objectives include: · To establish a nationally recognized standard of excellence, education and training for industrial refrigeration operators, technicians and supervisors. · To assist the refrigeration industry in developing and recognizing qualified refrigeration plant operators, technicians and supervisors. · To encourage continued technical training and education, as well as practical experience, of refrigeration plant operators, technicians and supen~isors. · ' To promote SAFETY in industrial refrigeration facilities. To increase public recognition of the skills needed in the industrial refrigeration field. Level B - Entry Level satisfactory completion of the following RETA industrial refrigeration educational coumes is suggested: / Industrial Refrigeration I ,/' Industrial Refrigeration [I / Industrial Refrigeration III v' Industrla! Refrigeration IV ,/' Basic Electricity ! : v' Basic Electricity II, Ladder Diagrams Level A - Journeyman Level / Study Courses outlined above / A minumum of two years verifiable experience in indus'Eial refrigeration plant operation or servicing. ..=..-.-_~ ~= ~-~. ,. iRafrigsration Engineers & T~cknicians Association RE T'A Kern Chapter -- REFRIGERATING ENGINEERS & TECHNICIANS ASSOCIATION MEMBERSHIP APPLICATION Date of Application Last Name First Name Middle Company Type of Business BuSiness Address City/State/ZIP Home Address City/State/ZIP Business Phone Business FAX Home Phone Intemet Address For Mailing ~ Use Business Address cI Use Home Address Check the category of membership for which you are applying (see reverse for requirements). Membership is based on the calendar year and not the anniversary date of joining. INDIVIDUAL MEMBERS INDUSTRIAL MEMBERS r~ Student . $30.00 ~ Regional Ir~lustrlal At Large $150.00 ~ Chapter IndivkJual* $85.00 ~] Regional Chapter' $150.00 *Chapter 'Chapter Includes ini~ation ($25), Na~fonal Dues Includes Na6onat Dues at ($120) and Chap~r Dues ($30) ($40) and Chapter Dues ($20) ~ National Industrial At Large $300.00 ~] Member-At-Large $85.00 Includes initiaEon ($25) and dues ($60) National Chapter' $300.00 Chapter 'Includes Na~onal Dues ($240) and Chapter Dues ($60) Remit Payment To: Refrigerating Engineers & Technicians Association P.O. Box 809188, Chicago, IL 60680-9188; (312)52'/'-6763 IMPORTANT NOTICE INDUSTRIAL MEMBERSHIPS ARE IN THE NAME OF THE COMPANY, WHICH CAN ELECT ONE INDIVIDUAL TO ACT AS COMPANY REPRESENTATIVE. No Purchaoe Orders Accepted ContHbutlonl or glft~ to RETA are not deductible ~= charitable contrlbutlon~ for fedmll income tax purpo=e~. Payment of member=hip dues · may be deductible a. an ordinary -,nd ne~:euary bu~ineu expense. Please consult your tax advisor. Januar/17 INDIVIDUAL MEMBERSHIP Industrial Membership shall be restricted to firms rather than persons. Industrial members shall Student Member - Shall be a full-time registered designate a representative who shall vote on student in a university, junior college or a profes- behalf of the firm and be eligible for any office of sional trade school who is pursuing a course of the association. study in preparation for a career in the refrigeration industry. Industrial members may purchase publications and training aids at member pdces and may take Chapter Member - Shall be restricted to persons the member discount for attendance at educa- qualified for membership in the association and as a tional programs, conferences and conventions. member in good standing desires to be a member of a duly chartered chapter of the association. An Industrial Membership shows your company's commitment to the ideals and goals of RETA, Member-At-Large - Shall be restricted to person which is the continual education and training in otherwise qualified for memberhip in the association the safe and efficient operational practices of who are so located by residence or business asso- industrial refrigeration systems. ciation or otherwise as to be inaccessible to a chapter's activities or through their own choice, A RETA Industrial Membership should be desires to hold Membership-At-Large. thought of as a donation to RETA as a sponsor- ing member. This financial support helps to develop engine room personnel who will operate INDUSTRIAL MEMBERSHIP equipment properly. REGIONAL -- This Industrial Membership is not intended to replace the need for operators to become indi- Permits a firm to show its support of the refrigerat- vidual RETA members. Companies should be ing industry, RETA and the RETA chapters located within its region, encouraged to sponsor, i.e., .pay for their em- ployees to become individual members. NATIONAL -- Permits a firm to show the broadest possible sup- These Industrial Membership benefits and port of the refrigerating industry and RETA. privileges can be extended to all division or plant locations of a single corporate entity. This mem- Firms engaged in manufacturing, selling, distdbut- bership status, however, does not include any ing, jobbing, contracting, servicing, installing, oper- subsidiary corporate entities which are eligible ating or otherwise associated with the refrigerating for Industrial Membership in their own right. industry are eligible for Industrial Membership in the RETA 401 N. Michigan Ave. Chicago, IL 60611-4267 (312)527-6763 FAX (312)527-6774 BAKERSFIELD FIRE DEPARTMENT February 19~ 1997 Joe Fonseca, plant Manager F~ CH,r~ Pepsi Cola Bottling Company MICHAEL R. KELLY 215 East 21~ Street m~m~.snv~ mmcta Bakersfield, CA 93305 2101 'H' Street ~a~e~e~, CA 9~0~ RE: Risk Management Program lmpeetion Tours (805) 326-3941 FAX (805) 395-1349 Thank you for the assistance of Production Supervisor Chad Bucchcl in SUmmS~N S~nCES conducting m~nbers of thc Bakersfield Fire Department through the bottling plato facility. 2101 'H" Street ~esfie~a. CA 93301 The purpose of these tours was to ~alxliliarizc the ~l'efJghters with thc ~acility and to r~vicw c805~ 326-394~ the Risk Management and Prevention Program (RMPP) associat~l with thc anhydrous FAX (805) 395-1349 ammonia system on site. 1715 Chester Ave. The firefJghters r3~scd a number of issues during the tours. I wiJl expand on them Bake~sfiela, CA 93301 ~805~ 326-3951 here for your benefit. FAX (805) 326-O576 I). Ammonia pressure relief valves currently v~nt to atmosphere. This EU~mnMEm~ S~C~S present situation is very precarious due to the proximity of the adjacent 1715 Chester Ave. ~m,e~a, c^ 9330~ school and nearby residences. Any upset of the ammonia system could (80~) 326-3979 expose these sensitive receptors to accidental releases of ammonia. The FAX (805) 326-0576 City of Bakersfield has had recent success with the Crystal Geyser m~n~no o~V~lOn bottling plant where ammonia pressure relief vents are placed into a water 56a2 wctor s,eet tank to absorb the released ammonia. A letter to the Governor's Office of B~ersfielcl, CA 93308 ~805) 3~-a6~7 Emergency Services is enclosed as a testimonial to the effectiveness of FAX (805) 399-5763 routing ammonia pressure relief vents into a water sparge tank. Chad Buechel suggested routing the Pepsi-Cola ammonia system vents into the waste water holding tank. This may be an acceptable alternative provided that sufficient water supplies exist to absorb one pound of ammonia per gallon of water. Additional water could be introduced into the holding tank upon activation of an ammonia leak detector should concentrations exceed the absorption capacity ofthe.:tank volume. Our office is ' especiallyleager to. work with you' off instituting a System' tO,control'and ".' mit!gate a possible ammonia vent release as soon as practicable. 2). Ammonia compressor "kill switches" are desired in the diffusion system control box. This would allow the firefighters to shut down the compressors without having to enter the plant, thus protecting the equipment form damage should the diffusion system need to be activated, as well as protecting the firefighters from ammonia exposure upon entering the plant. 3). A chain and chain tensioner was observed attached to, and ostensibly supporting, an ammonia suction fine. If the ammonia line is saggi~ a permanent structural support should be engineered and installed. 4). The old wood U-uss building homing the carbon dioxide bulk tank, lube oils, ~ gas . cylinders and vending machine parts is a particular fire safety concern. Due to its deteriorating condition, heavy fire load (wood frame construction, combustible storage, etc.) and susceptibility to vandalism and vagrant intrusion, housekeeping and security should be of utmost importance m this area of the plant. Too often, there is a tendency for the deteriorating parts of facilities to receive the least amount of maintenance. This was evident by the missing ceiling files, disconnected and hanging electrical conduit, and use of extension cords.in place of permanent wiring. Should this area of the plant become involved in a fire due to poor housekeeping, electrical short, or va~dallsm, not only would the ammoma and other compressed gas cylinder in storage become involved, but also the whole ammonia system m the adjacent bottling plant would be exposed to the radiant heat. Continuing efforts should be made to ensure that this oldest part of the facility does not dc~riorate into an imminent fire boTard. 5). As a coincidence, on February 13, 1997, as the firefighters were arriving for tl~ plant tour, we were informed ora propane gas leak incident occurring in the plant. While the evacuation of the plant wea~t smoothly, the use of a Unified Incident Command System would have improved coordination between facility responders and emergency responders. The Bakersfield Fire Department offers training on the Incident Command Systean. We will be happy to provide instruction to the plant personnel who have responsibilities for facility emergency response and employee safety. Please give me a call, and I will coordinate the training, perhaps in conjunction with other local ammoma refrigeration facilities. 6). The emergency fuel pump shut off should also stop the propane tank m addition to the diesel dispenser. On behalf of the Bakersfield Fire Department, we appreciate the cooperation of your staff; especially that of Chad Buechel, in conducting these recent tours. We look forward to a timely resolution to the issues expressed herein. If you have any questions, please call me at 326-3979. Sincerely, Hoxxard H. Wines, III Ha?ardous Materials Technician HHW/dlm cc: Ralph Huey enclosure BAKERSFIELD FIRE ·DEPARTMENT November 26, 1996 Mr. Joe Fonseca, Plant. Manager Pepsi-Cola Company nRE.C.~E; 215 E. 21st Street MICHAEL R. KELLY Bakersfield, CA 93305 S,~41Nmm~nVESERV~CES RE: Risk Management Program Audit Meeting 2101 'H" Street Bakersfield, CA 93301 (805) 326-3941 Dear Mr. Fonseca:. FAX (805) 395-1349 Thank you, and thanks also to your Production Supervisor, Chad Buechel, for meeting with SUPPRESSION SERVICES 2101 'H' Street me on November 1, 1996 to discuss the status of the Risk Management and Prevention Plan Bakemfield, CA93301 program (RMPP) for your facility. Effective January 1, 1997, California law will adopt the · (805)326-3941 federal Risk Management Program regulations as a significant amendment to the existing FAX (805) 395-1349 RMPP program. The State is currently developing regulations to implement the change in law, and the regulations are expected to be completed by mid-1997. By mid-1998, or as PIL~EVENTION SERVICES 1715 Chester Ave. otherwise specified by those regulations, facilities should expect to' aChieve compliance with Bakersfield, CA 93301 the new federal requirements. (805) 326-3951 FAX (805) 326-0576 For your information, I've enclosed a summary Fact~eet on the federal Risk Management ENVIIR)NMENTAI. SERVICES Program. Your facility would appear to qualify for Program 2 requirements under the new 171,5 Chester Ave.' law. This would entail a new hazard analysis and off-site consequence according to particular Bakersfield, CA93301 "endpoint" criteria as referenced by federal rule. 'Guidance for anhydrous ammonia (805) 326-3979 FAX (805)326-0576' refrigeration facilities has been produced by the EPA, however it may be premature to recalculate accidental release parameters until the California regulations are final. /RAINING DIVISION ' 5642 Victor ~reet One thing I did notice during our audit,.was that Operating Procedures in particular, were not Bakersfield, CA 93308 readily available at the applicable equipment, nor were they easily referenced upon request. (805) 399-4697 FAX (805)399-5763 These procedures were included, to some degree, in the. existing RMPP prepared by WZL However, by definition, these procedures are most effective when in the hands of operators themselves. My recommendation is to develop additional written procedures for the operation of all equipment associated with the ammonia system and,. to post the same at the equipment itself. All valves, piping, switches, and other appurte, nhnces referenced in the operating procedures should be clearly marked with identification tags and hazard warnings. By contrast, your preventative maintenance and training procedures are well documented. With the additional attention to the operating procedures, as I suggested, I am confident that you will easily transition to the new federal requirements when they become effective. .If you have any questions, please feel free to call me at 326-3979. Sincerely,. Howard H. Wines, III enclosure Hazardous Material TechniCian April 16, 1996 RECEIVED City of Bakersfield Fire Department 1715 Chester Ave: Bakersfield, CA 93301.. HAZ, MAT. DIV. Atten. Mr. Howard H. Wines, III Mr. Wines, Attached is the "Self-Certification" check hst. Please note that there have been changes in the management staff of the Pepsi-Cola Company. Mr. Kevin Phillips left the company in June 1994 and Mr. Bill Bentley retired inDecember 1995. I would just like to assure you of our continued commitment to providing the safest possible operation in regards to the handling of Acutely Hazardous Materials. Our plan is to improve upon and ensure comphance with the RMPP in all aspects. regarding "Training", "Handling", "Maintenance", "Detection", "Monitoring", and "Risk Reduction" in the handhng of AHM's. If you have any questions or concerns please contact me at 635-1185. Sincerely, Joe Fonseca, Plant Manager Pepsi-Cola COmpany Bakersfield, CA PEPSI-COLA COMPANY 215 E. 21ST STREET, BAKERSFIELD, CALIFORNIA 93305 (805) 635-1100 · (805) 326-0913 FAX EQUIPMENT LISTS CHANGES 'Referencing Section 3.0, Equipment Report, Page 15. Bottle Line Ammonia Comoressor #3 This compressor has been taken out of use effective January 1996. It was removed from operation. The replacement compressor is' in place but has not been connected 'to the existing plumbing. A revision notice will be forwarded when the installation is complete. Ammonia Compressor Planned Maintenance All Ammonia Compressors are going to be scheduled to be rebuilt during 1997. The rebuilding will be completed in phases and revisions will be forwarded as the work is completed. Manufacturer VILTER Size A10K448B · -Serial Number 22200 ' ' Age: Built in 1980 Condition: Well maintained, good condition · E(~uioment: Bottle Line - Oil Separator #1 Nature: This vertical oil separator removes oil from the high pressure ammonia vapor discharging from the #1 compressor. Oil is · automatically drained from the separator into the compressor. Manufacturer Globe Ice Machine Co. Inc. Size 16 inch O.D. by 2 ft. 9 in. seam to seam shell length Revised April 151 1.996 .Page 15 11.0 . RMPP IMPLEMENTATION "ImplementatiOn of the RMPP shall include carrying out all operating, maintenance, monitoring, inventory control, equipment inspection, auditing, record keeping, and training programs .as required by the RMPP." 11.1 Personnel Resoonsible for RMPP ImOlementation~ The title of each person, charged'with RMPP implementation duties are listed below, along with their respective responsibihties. Title RMPP Implementation Res~onsibihties Plant Manager Supervise audits, inspection and record keeping, .responsible for RMPP implementation. Production Supervisor Supervise ammonia equipment inspection, emergency response training, operating and maintenance training, inventory control and labehng. Production' Supervisor .Supervise WWTS inspection, emergency response training, operating and maintenance training, inventory control and labeling. All Employees Undergo emergency response and evacuation training. ..' Revised'April 15, 1996 Page 51 13.0 QUALIFICATIONS OF CERTIFIERS 13.1 .Qualified Person Mary Jane Wilson. President,~W'ZI Inc. Ms. Wilson received a Bachelor of Science Degree in Petroleum Engineering from Stanford University in 1972. She is registered as an Environmental Assessor in Cahfornia. Ms Wilson is the President and Chief Executive Officer of WZI Ind. She monitors WZI Inc. projects to maintain technical standards. She has extensive experience (20 years total) in the petroleum and environmental consulting industries. She has participated in the design of numerous compliance programs related to the environmental safety of operating facilities. 13.2 Joe Fonseca, Plant Managerz Mr. Fonseca has worked for the Pepsi Cola Company for 26 years, the last 1.5 years as Plant Manger of the Bakersfield Facility. He previously worked in the Sacramento Facility as Quality Control Manager and Maintenance Manger just prior to relocating. to Bakersfield. Revised April 15, 1996 Page 56 APPENDIX A · AMMONIA SAFETY AUDIT FACILITY: PEPSI-COLA Bottling Company ADDRESS: 215 East 21 st Street, Bakersfield, California 93305 TELEPHONE: (805) 635-1100 DATE OF AUDIT: KEY FACILITY PERSONNEL:a 'General Manager: John Timpani Plant Manager: Joe Fonseca AMMONIA SAFETY AUDIT TEAM: Plant Manager: Joe Fonseca Product Availability Manager: Jim Ash Production Supervisor: Chad Buechel Production Supervisor: Stan Matthews Maintenance Employee: Danny Barnes Maintenance Employee: Alex Matthews Maintenance Employee: Terry Nord 3 Revised.April 15, 1996 Appendix A Page 4 APPENDIX A SULFURIC ACID SAFETY AUDIT FACILITY: PEPSI-COLA Bottling Company ADDRESS: 215 East· 21 st Street, Bakersfield, California 93305 TELEPHONE: (805) 635-1100 DATE OF AUDIT: KEY FACILITY PERSONNEL:4 General Manager: jOhn Timpani Plant Manager: Joe Fonseca SULFURIC ACID SAFETY AUDIT TEAM: Plant Manager: Joe Fonseca Product Availability Manager: Ji·m Ash ProductiOn Supervisor: Chad Buechel Production Supervisor: · Stan Matthews Maintenance Employee: Danny Barnes QUality Control Employee: Barringt°n Lewis Quality Control Employee: Laurie Thake 4 Revised April 15, 1996 Append£x B Page 4 I¥. REVISION RECORD All records concerning' this RMPP shall be kept for at least five years (Section 25534 (0). · Necessary revisions to the RMPP will be made at least every three years. The RMPP must be modified within'60 days of a modification that materially affects the handling of an AHM (Section 25534(h)). 'All revisions to this RMPP are to be recorded here.. Revision Pages Date of' Signature of PersOn Number Affected Revision Making the Revision 7. 8. 9. 10. Page 4 RECORD OF TELEPHONE CONVERSATION Location: ~2 ;~-- C_. "Zt ~'-~ -~ ID# Business Name: Conta~ Name: Business Phone: ~3~ ~ ~/?~ F~: Inspe~or's Name: Time of Call: Dine: ~o~c~ Time: /~ · Min: Type of Call: Incoming [ ] Outgoing [~ Returned [ ] Actions ReqUired: ., ~~__~ CHAD BUECHEL PRODUC T/ON SUPERV/$OR 215 E. 21ST STREET BAKERSFIELD, CA 93305 (805) 326-0913 FAX (805) 636-8581 PAGER Time Required to Complete Activity Cf Min: ~ ~/~ _ 10/22/96 PEPSI COLA BOTTLING COMPANY 215-000-000984 Page 1 Overall Site with 6'Fac. Units General Information Location: 215 E 21ST ST Map:103 Haz:4 Type: 3 City : BAKERSFIELD Grid: 29A F/U: 6 AOV: 0.0 Contact Name Title Contact Name Title JOE FONSECA ./ PLANT MANAGER CHAD BUECHEL / PRODUCTION SUP Business Phone: (805) 635-1100x Business Phone: (805) 635-1100x 24-Hour Phone : (805) 635-1185x 24-Hour Phone : (805) 635-1170x Pager Phone : ( ) - x Pager Phone : ( ) - x Summary Hazmat Inventory List in MCP Order Ail Materials at Site F/U Material Name '--Hazards-- Max Qt¥ Unit MCP F/U: 02 - MANUFACTURING PLANT/OFFICE AMMONIA F P R IH 21375 FT3 Extreme NW CORNER & MIDDLE RM #5 ACETYLENE F P IH 144 FT3 High S WALL ROOM #5 LIQUEFIED PETROLEUM GAS F P IH 36980 FT3 High CENTER S FENCE ROOM #7 CHLORINE WATER TREATMENT R IH 200 GAL High SE CORNER ROOM 5 & SW CORNER ROOM 7 SULFURIC ACID F IH 500 GAL High ALLEY NEAR VENDING ROOM 8 OXONIA ACTIVE R IH 150 GAL High ROOM #5 C/P AREA PHOSPHORIC ACID IH 90 GAL Moderate MIDDLE OF ROOM 3 & MIDDLE OR ROOM 4 SODIUM HYDROXIDE R IH 500 GAL Moderate ALLEY BETWEEN VENDING & FLEET ROOM 8 PRINCIPAL F R IH 160 GAL Moderate ROOM #5 C/P AREA ENFORCE R IH 165 GAL Moderate ROOM #5 C/P AREA BEVRO SHEEN (CAUSTIC CLEANER) R IH 200 GAL Moderate ROOM #5 CAUSTIC TANK WASHER AQUA CLEAR IH 112 LBS Low SW CORNER ROOM #5 (SHOP) DIESEL FUEL #2 F IH DH 15000 GAL Low ISLAND CENTER ROOM #7 GEAR OIL F DH 120 GAL Low 10/22/96 PEPSI' COLA BOTTLING COMPANY 215-000-000984 Page 2 Hazmat Inventory List in MCP Order Ail Materials at site F/U Material Name / Location --Hazards-- Max Qty Unit MCP F/U: 02 - MANUFACTURING PLANT/OFFICE SW CORNER ROOM #3 OXYGEN F P IH DH 281FT3 Low S WALL ROOM #3 ARGON F P' IH 333 FT3 Minimal S WALL ROOM #5 BEARING OIL F DH 110 GAL Minimal SW CORNER ROOM #3 CARBON DIOXIDE F P IH 52700 FT3 Minimal NW CORNER RM #5 AND #1 CITRIC ACID IH 2400 LBS Minimal N WALL ROOM #3 HYDRATED LIME IH 1200 LBS Minimal SE CORNER ROOM #5 NITROGEN F P IH 5290 FT3 Minimal E WALL ROOM 4 & SW CORNER ROOM 3 REFRIGERATION OIL F DH 110 GAL Minimal SW CORNER RM #3 PET STAR (CONVAYOR LUBE) F R IH 385 GAL Minimal ROOM #5 & OLD VENDING BLDG SODIUM BENZOATE R IH 1200 LBS Unrated N WALL ROOM #3 SYNTHETIC DETERGENTS DH 165 GAL Unrated NW CORNER ROOM 7 & S WALL ROOM 5 COOLING WATER TREATMENT IH 220 GAL Unrated F/U: 04 - VENDING CARBON DIOXIDE F P IH 2720 FT3 Minimal NE CORNER OF ROOM 94 CARBON DIOXIDE REFRIGERATED LIQUID F P IH 425000 FT3 Minimal E WALL ROOM #4 F/U: 05 - FLEET/SUPPLY WAREHOUSE NALCOOL #2000 DH 55 GAL High SW CORNER ROOM #2 TRANSMISSION FLUID F DH 100 GAL Low CENTER ROOM #2 GEAR OIL F DH 200 GAL Low CENTER ROOM #2 OXYGEN F P IH 481FT3 Low NW CORNER RM #2 GREASE F DH 55 GAL Minimal E WALL CENTER RM #2 MOTOR OIL F DH '350 GAL Minimal CENTER ROOM #2 ABSORBS IT #01037 DH 600 LBS Unrated CENTER S WALL ROOM #1 UNITED STATES POSTAL SERVICE · ~ c~: PENALTY FOR PRIVATE · USE TO AVOID PAYMENT ,'.~.~; oF POSTAGE, ~00 Print your name, address and ZIP Code here · CITY OF BAKERSFIELD FIRE DEPT. OFFICE OF ENVIROlfl~ENTAL SERVICES 1715 CEESTER AVENUE, SUITE 300 BAKERSFIELD, CA 93301 SENDER= ' Complete items 1 and/or 2 for additional services. , ~' I also wish to receive the · Complete items 3, and 4a & b. ~ following services (for an extra · Print your name and address on the reverse of'ibis form s'o that we can fee): return this card to you. · Attach this form to the front of the mailpiece, or on the back if space 1. [] Addressee's Address does not permit. · Write 'Return Receipt Requested" on the mailpiece below the article number. 2. [] Restricted Delivery · The Return Receipt will show to whom the article was delivered and the date delivered. Consult postmaster for fee. 3. Article Addressed to: 4a. Article Number P-390-214-484 KEVIN PHILLIPS, O~ERATIONS I~GR 4b. Service Type PEPSI COLA BOTTLING COI~PAtg~ ', [] Registered [] Insured 21.~ F_,AS'~ 21ST S~I;[EE'[' / ~::ertified [] COD BAKERSFIELD, CA 93305 //f <~' ', [] Express Mail [] Return Receipt for Merchandise ~ 7. Date oLDelivery 5. ~S~dnattwe (Addressee) .-..... TM 8. Addressee's Address (Only if requested ~..T~. ~j~ure (Agent) PS Form 381 1, December 1991 ~U.S. GPO: 1993--352-714 DOMESTIC.RETURN RECEIPT P 390 214 484 Receipt for Certified Mail No Insurance Coverage Provided ~Ds~,T~s DO not use for International Mail (See Reverse) Sent to KEVIN I~HILLIPS, MANAGER Street and NO. PEPSI COlA BOTTLING CO. P.O., State and ZIP Code 215 EAST 21ST STREET Postage $ · 3 2 Certified Fee 1.10 Special Delivery Fee Restricted Delivery Fee O3Return Receipt Showing to Whom & Date Delivered ]- ,~ Return Receipt Showing to.Whom, ~: Date, and Addressee's Address -3 TOTAL Postage Postmark Date or CITY o/BAKERSFIELD FIRE DEPARTMENT FIRE SAFETY SERVICES & OFFICE OF ENVIRONMENTAL SERVICES 1715 CHESTER AVE. · BAKERSFIELD, CA ° 93301 March 26, 1996 . :. R.E. HUEY R.B. TOBIAS, HAZ-MAT COORDINATOR (805) 326-3979 FIRE MARSHAL (805) 326-3951 Kevin Phillips, Operations Manager Pepsi Cola Bottling Company 215 East 21st Street Bakersfield, CA 93305 Certified Mail NOTICE OF RECERTIFICATION REQUIREMENT for the RISK MANAGEMENT and PREVENTION PLAN "Self-Certification Process" Dear Mr. Phillips: Approximately three to five years ago, you or someone under direction from your facility submitted a Risk Management and Prevention Plan (RMPP) document to this office. State law requires that your business review the RMPP every three to five years and make necessary revisions. Our records indicate that it is now time for your business to conduct a review ._~.. of the RMPP document, make any necessary revisions, and submit the "Self-Certification" checklist along with any necessary RMPP changes to this office no later than 30 days after receipt of this,. letter. To assist you in the review process, the following guidance documents are enclosed: ~ · A brief summary of the current RMPP strategies for your facility. This is only for your ~. convenience, a thorough review of the entire RMPP document is also required. · "Self-Certification" checklist to be signed and returned along with any RMPP revisions. If you have any questions regarding the RMPP review process, preparation guidelines, or required elements, please call Howard Wines at 326-3979. Sincerely, Howard H. Wines, III Hazardous Materials Technician HHW/dlm enclosures RMPP FIVE YEAR REVIEW BUSINESS NAME: Pepsi Cola Bottling Company LOCATION: 215 East 21 st Street PRIMARY RMPP CONTACT: Kevin Phillips, Operations Manager PHONE NUMBER: (805) 327-221.0, 24 hr. (805) 589-5695 RMPP MATERIAL & QUANTITY: Ammonia 21,375 cu.ft. Sulfuric Acid 650 gallons RMPP IMPLEMENTATION STRATEGIES: Inspection program. Annual safety audit. Written operating and maintenance procedures. Operating and maintenance procedures training. Emergency response and evacuation training, Labeling of ammonia lines and other hazards. Employees trained in use of self contained breathing apparatus. Coat sulfuric acid containment basin, Evaluate bracing of ammonia vessels. Develop sulfuric acid delivery and transfer procedure, Procedure for coordinating with, and notifying adjacent school. Ammonia diffusion system. SELF-CERTIFICATION [ ] The RMPP originally consisted of either eliminating, substituting, or else reducing the type.and quantity of acutely hazardous materials below the threshold planning quantities, and this is still in effect. (Ifyas, please check ~his box and sign the Certification St~ment below and return this form). Please aubmit updatea and change8 for any of the following elements: Check as Reviewed [ ] The RMPP shall identify, by title, all personnel at the business who are responsible for carrying out the specific elements of the RMPP, and their respective responsibilities. · [ ] A detailed training program to ensure that those persons specified in the RMPP are able to implement the RMPP. [ ] A description of each accident involving acutely hazardous materials since the RMPP was prepared, together with a description of the underlying causes of the accident and the measures taken, if any, to avoid a recurrence of a similar accident. [ ] A report specifying the nature, age, and condition of the equipment used to handle acutely hazardous materials at the facility and any schedules for testing and maintenance. [ ] Design, operating, and maintenance controls which minimize the dsk of an accident involving acutely hazardous materials. [ ] Detection, monitoring, or automatic control systems to minimize potential acutely hazardous materials accident risks. [ ] The implementation of additional steps to be taken to reduce the risk of an accident involving acutely hazardous materials. These actions may include any of the following: · Installation of alarm, detection, monitoring, or automatic control devices. · Equipment modifications, repairs, or additions. · Changes in the operations, procedures, maintenance schedules, or facility design. [ ] Auditing and inspection programs designed to confirm that the RMPP is effectively carried out. [ ] Recordkeeping procedures for the RMPP. [ ] A clearly prepared map noting the location of the facility which shows schools, residential areas, hospitals, health care facilities and child day care facilities and the zones of vulnerability, including the levels of expected exposure in each zone. If no such map was prepared originally, one is now required. Please call 326-3979 for more details. CERTIFICATION STATEMENT I, hereby certify that I have reviewed the existing Risk Management (Name of Facility Operator) and Prevention Plan (RMPP) for and that it, along with any (Name of Facility) corrections or additions submitted herewith, constitutes a current and complete RMPP according to the checklist above. (Signature) (Date) Please mail this "Self-Certification" form aJong with any corrections and additional RMPP information to: Bakersfield Fire Department, Office of Environmental Services 1715 Chester Ay. 3rd Floor Bakersfield, CA 93301 FRANK JACKMAN REFRIGERATION, INC. Design · Sales · Service · Installation 16013 Valley View · Santa Fe Springs, CA 90670 · Tel: (310) 921-1329 · Fax: (310) 926-5771 10/22/93 Ralph Huey .... Ha.zard.ous.~.Ma~er-iats_~ ......................... 2130 "G" Street Bakersfield, CA 93301 Dear Sir, The Ammonia Diffuser fabricated and installed for the Pepsi-Cola / Dr. Pepper Facility will function in the horizontal position properly. The holes drilled in the delivery pipe down the center of the Diffuser are drilled in a manner so as to allow the gas 'to be distributed in the direction of the incoming water. The water will fill the chamber up from the bottom radius and will be sufficient to absorb the vapor as long as the GPM requirements are at the minimum or above. Sincerely, F~ank FJ/mef CITY of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON BAKERSFIELD, 93301 FIRE CHIEF 326-3911 SITE PLAN REVIEW/PLAN CHECK Re! Pepsi Cola, 215 E. 21st St. Personnel at plant who will be trained to operate system shall also be trained in use of self-contained breathing apparatus and should have HAZWOPER (40 hour) training. Emergency refrigerant control box should be located outside of building. Contact City of Bakersfield Wastewater to confirm permission for this system to dump into sewer. A durable placard shall be provided in the direct proximity of the fire department connection stating the gallons per minute needed in a situation where the City water main is not operating. Date Typed: 8/31/93 Typed By: dlf cc: Ralph Huey/City Fire Department, Hazardous Materials Division WDPRFPLANSC H EC K:215E21 ST .-il Kohlenberger Associates Consulting Engineers, Inc. August 22, 1993 ~-'~· City of Bakersfield Fire Department 2101 H Street I Bakersfield, CA 93301 Attention: Mr. Larry Tolar, Fire Marshal I Subject: Pepsi-Cola, Bakersfield Ammonia Diffusion System ,~ Frank Jackman Refrigeration, Inc. Dear Marshal Tolar: -~l We are responding to a request by Frank Jackman to review and approve the calculations and submittals on the subject project per your request letter to him dated July 12, 1993. I The basic philosophy of an ammonia diffusion system is "to contain and control" the ammonia charge within the system. The function of the diffusion system and control box i is to provide the ability of the designated person in authority during a fire or other emergency to respond appropriately. This includes the ability to manually reduce and equalize pressures within the system due to fire and heat in order to prevent the pressure vessel relief valves from relieving to atmosphere (which is the ultimate I protection to overpressure). This ability is provided by the cross over valving and pressure gauges contained in the ammonia diffusion emergency control box. I ., The ultimate ability to blend the charge with water in an ammonia/water mixer is · required if the equalization procedures are not sufficient to maintain pressures below the relief valve settings. This allows central control and diffusion of the mixture into the sewer or retention tank/area to provide ultimate control of the pressures without '1 necessarily "dumping" the entire charge. The sizing of the ammonia/water mixer in a diffusion system is dependent on the I maximum flow response of ammonia into the mixer when the control valves are manually opened. The character of the flow of ammonia to the mixer from a vessel filled with ammonia liquid is that the ammonia will flash into vapor from the pressure in its .· vessel down to atmospheric pressure. This pressure reduction will create flash gas of approximately 20% of the weight of the liquid in the vessel. This action also subcools the liquid ammonia to the saturation temperature (-28F) corresponding to 0psig (atmospheric) pressure. I At this point, the ammonia will lie essentially dormant and gas off at a rate established by the amount of external heat absorbed by the containing veSsel and at a constant -, pressure slightly above atmospheric. The maximum flow rate (design flow) is · experienced during the initial flashing of the contents down to atmospheric pressure. FooO mclustry I;acilit~es/Systems · Feasibihty Studies · Industrial Refrigeration · Pollution Control · Air Conditioning · Freezing · Cold Storage · Cogenerahon · Energy Management · Plant Engineering Mai[ Address: P.O. Box 5037. Fullerton, CA 92635 · Office Location: 611 South Euclid Street. Fullerton, CA 92632 · (714) 738-7733. TELEFAX {714) 738-3905 I This flash down time is calculated by considering the enthalpy (heat content) of the liquid ammonia from the original condition (avg 80F) down to the final condition (-28F) as well as the enthalpy (heat release) of vaporization. By calculation, the total I heat which has to be absorbed and is therefore flashed by contained ammonia off the during the process, based on 20% of the 1000 lb. charge flashing off is 214,000 btu. Considering that this boil off is carried by (4) 1" diffusion lines to the mixer, their I capacity (as suction lines per ASHRAE flow/capacity data) under these conditions is approximately 192,000 btu/hr. I The flash down time then would be 214,000 btu/192,000 btu/hr= 1.1 hrs--67min. Therefore, the amount of water required to mix 2gal/lb of ammonia with 2001bs/67min= 3. Ibs/min x 2gal/lb= 6 gpm. It' is therefore apparent that the ammonia/water mixer proposed is more than sufficient to carry out this task since its I water flow capacity based on a 1-1/4'" water line @ 50psig water pressure is in excess of 50 gpm. I We have reviewed the calculations already submitted by Jackman Refrigeration ( W.R. UIIrich letter/analysis, 7/30/93) and find them to be more conservative than these calculations conclude and are therefore approved as being appropriate for this service. I Please review these findings and call to discuss further if you desire.' Sincerely, · · . I Kohlenbe. r~:~r Associates Charles R. Kohlenberger, PE I President ! ! ! FRANK CKMAN REFRIGE TION, INC. Design · Sales · Se~ice · Installtion 16017 Valley View, Santa Fe Springs, CA 90670 ° Tel: (310) 921-1329 · Fax: (310) 926-5771 5/24/93 Pepsi-Cola - Dr. Pepper Bottling Company Of L.A. 215 E. 21st St. Bakersfield, CA 9'3305 BUSINESS PLAN AS IT APPLIES TO AMMONIA RELEASES: In the event that the odor of ammonia is detected in the Facility, it shall be immediately reported to the Maintenance Department as well as the Fire Department. If the event occurs after regular business hours, the designated Superintendant, , should be notified immediately. If the Superintendant cannot be contacted, the Plant Manager, , should be contacted. If there is no prompt response, and the evidence of ammonia continues, Frank Jackman Refrigeration, Inc. should be contacted immediately at (310) 9.21-1329. If there is any apparent danger to personnel, they should be evacuated from the effected area immediately. Any open flames in the area must be extinguished and the area ventilated. Upon arrival of the Fire Department, the effected area and the location Control Station should be identified. of the Emergency Refrigerant The Emergency Control Station consists of a manifold with valved connections and guages piped into the high side and low side of each system. These connections are also provided with equalization valves between each high side and low side. The Control Box Station is.fitted with a valve, guage and check valve connecting the manifold to an ammonia/water mixing device which discharges into a holding tank. There is also a water connection, with.a manual valve, and provision for a fire hose connection, (to be used in the event that there is a loss of Plant water supply), connected to the mixer. Located adjacent to the station is an emergency switch for the shut down of the refrigeration system in the Equipment Room. In the event that the ammonia/water mixing device is used and there is a mixture of ammonia and water 'in the Holding Tank, it must be neutralized and checked by the Fire Department before being disposed of to any sewer or other waste system. The operation of the Ammonia Refrigeration Control Station must be Emergency directed by knowledgeable personnel with it's operation. FRANK JACKMAN REFRIGERATION, INC. Design · Sales ° Se~ice ° Installtion 16017 Valley View, Santa Fe Springs, CA 90670 ° Tel: (310) 921-1329 ° Fax: (310) 926-5771 BUSINESS PLAN AS IT APPLIES TO AMMONIA RELEASES - CONT. Page 2 In addition to Fire Department notification of any ammonia release, any release of ammonia in excess of 100~ in a 24hr. period must also be reported to the E.P.A. within 24hrs. of any .such release. The Pepsi-Cola - Dr. Pepper Plant ammonia refrigerant charge is less than 1000~. If we use (2) gallons of water to diffuse (1) pound of. ammonia, when the system's pressure is equalized and venting, we will require no more than a 2000 gallon Holding Tank. The chart provided by the Bakersfield Fire Department denotes the required sizes of the diffuser: A) 6' 6", B) 6' 3½", C) 400, D) 1", E) 6" F) 1~" When a portion of the system, or a vessel, is vented to the diffuser, the pressure in that portion of the system or vessel drops, and providing there is some liquid ammonia in that portion of the system, the vaporization of the ammonia naturally cools that portion of the system down, protecting the vessel, compressor or piping from failing due to overheating. The operation of the Ammonia/Water Mixer must be conducted by personnel knowledgeable in its use. The water must be flowing before the ammonia liquid or vapor is allowed to enter the Mixer, and the pressures must be constantly monitored during the mixing operation. In the event that there is an inadequate water in the there is 2½" fire hose building pressure system, a connection that can be used to supply the water needed to neutralize the ammonia. Face and eye protection must always be used during the use of the "Emergency Ammonia Refrigerant Control System", any liquid ammonia that may get into the eyes must be rinsed out, with water, within 11 seconds or irreversible damage may occur. This system has been designed to diffuse all the ammonia properly and safely to a neutralized state for storage in the Holding Tank. The entire charge of ammonia and water required as well as the needed surface area and pressures required for this diffusing process have been factored into it's design. I 1601~' Valley View, Santa Fe Spdngs, CA 90670 · Tel: (310) 921-1329 · Fax: (310) 926-5771 I -~" ! I ~ ' ~o~ ~LF~ , ' · I FORM EIO (7/87) ~~ FRANK CKMAN REFRIGE TION, INC. Design · Sales · Service · Installtion 6015 Valley View, Santa Fe Springs, CA ~670 ° Tel: (310) 921-1329 · Fax: (310) 926-5771 I I FORM El0 (7/87) '~ FRANK CKMAN REF IGE TION, INC. I~'~'~" Design · Sales · Service Installtion 1601~' Valley View, Santa Fe Springs, CA 90670 · Tel: (310) 921-1329 · Fax: (310) 926-5~1 ~ '~ . J I I I , I "A" "B" "F' AMMONIA INLET NOTE WELD' SHUT' # 4" Sl'D PIPE SCALE: NONE OUTLET TO AMMONIA/'WATER HOLDING TANK NOTE 1 2 1/2" NAT'L STD FEMALE FIRE HOSE CONN. & SPRING LOADED CHECK VALVE-JAMES JONES #J-620 OR EQUAL CHARGE A B C D E F 1000 6'-6' 6'-5 1/2' 400 ,' 6' 1 2000 6'-6" 6'-5 f/2" 600 I I/4' 6"- 1,/2' 5000 8'--10" 8'-7 1/2" 800 I I/4' 10' I 1/2' 4000 8'--10' 8'-7 ~/2" 1000 I i/2' 10' 5000 8'-10". 8'-7 ~/2' 1200 I I/2' 10' 6000 8'-10' 8'-7 ~/2' 1400 2' 10' 2' 7000 8'-10" 8'-7 ~/2" 1600 2" 10" 2' 8000 8'-i0' 8'-7 ~/2" ~800 2' 10' 2 ~/2' 9000 uP 8'-10' 8'-7 i/2' 2o00 2' 10' 2 ,/2' THE TABLE ABOVE IS CITY OF VERNON STANDARD. THE TABLE BELOW I~AY BE USED ON V.F.D. APPROVAL ·HERE SPACE IS LI/~ITED. 1000 2OO0 $000 4000 5000' 6000 · 7000. 8000 9000UP 5'-6' 5'-6' 5'-6' 5'-6" '5'-6" 5'-6" 5'-6" 5'-6" F/RE DEPAR DIFFUSER I, Ulll .ix..~j[ ],[ il,il s L II1., · iT.L. I WII.LIAM FI. UI.LRIC.H, INC. 104 Oak Knoll Ian¢, 8rndburg, California 91010 7-- 30-92 I Frar~k Jackson Refr~gerat. ion~ ]:nc., 16013 Valley view Sar~t.e Fe LSor'ir~9~, Ga. 90670 Re:P~p,~i Plant, P,a. ker,s-F'ield, Ca. Dear Frank: Following is an estimate of the amount of wat~er required to neut. ra]ize the anhydrous ammonia ~o aqua ~mmOnia for cli$charge a ~tor'age l;ank or o~;hor Gi yen: Two systems operating at ~75 P8:[G on ~he h~gh side and 30 on the low ~de. ~ach system containing ~00 Lb, of anhy~rou~ ammonia. Each high eiee and low si~e connected ~o ~he ammonia- ~ater mixer wi~h ~ ~epara~e 1" ~ine. One ammonia-weber mixer wi~h a 6" diame:er shell, 6'~" A ~" ammonia in~ot tube w~h A00 3/32" ho~e~ and a 2 ~/2" national s~andard female fire hose connection and spr~n~ ~oa:ed check valve. A 4" ou~le~ ~o ~he ~ewer or ~orege If un,er ex~reme conditions all four l~ne~ ~o ~he ~wo were oper, ed at the ~ame ~me and ma~nta~ne~ the maximum flow ~here wou~d be ~ flow of ~524 Lb. of ammonia per hour. At ~000 Lb. of ammoni~ ~n both sye~em~ it wou~d ~ake approx~ma{ely ~3 ~/~ m~nu~ee ~o dump the en~re charge of bo~h sy~em~. A~low~ng 2 gallons of war. er- for each Lb, of ammonia, thi~ woul~ require a flow of ~SO GPM of wa~er ~o ~he mixer. As you know ~he pre~sure in ~he ~y~em~ would rapidly diminish when ~he l~nes are opened ~o the ~mmon~e-wa~er m~xer and maximum flow wou~ no~ be maintained. This would mean ~ha~ ~he ~me ~o to~ally empty bo~h sys~em~ would much longer and require a mu~h lower flow of wa~er to ~he mixer. Very Truly, W~llian'~ R. Ullrich 35 ')-25,50 · Fax (818) 359-3550 'l'de. phone (818)' c" m i Re:Frank Jackman Refrigeration, Pepsi-Bakersfield Project. E,~t. imate of the amount of water required to neutralize 1000# of anhydr'ou$ ammonia to aqua ammonia for discharge to storage tank or m oth¢:r facilities. 1)capm,mity of the mysbem=lo00~ m 2)Discharge Pre~ure:l 3)Lo~ side PKessure=30P81G ~)Bo~h line8 ~o w~er/ammonia mixer are 1" and'connected above any liquid ammonia levels. m on ~he highsiUe=1917 0)Maximum flow 6)Maximum flow from ~he low ~ide=345 ~/hr.~ ?)lotel flow =~2 ~/hr. m 8)No%e:Thi~ flow no~ likely ~o maintain a~ .t~i~ pressure a~ ~he normal evaporation of the liquid ammonia in the ~y~tem will not ~t. ain this pressure, however for ~o~t'case it i~ ~s~umed ~ha~ he m pre~ure wi l~ remain constant. 9)Tho ~ime required ~o dump ~he ~ntire charge mit:). ( 2262/1000 ) m lO)if we allow ~ 9al. of water for each lb. of ammonia, which over a 100A s~fe~y factor i~ will require a flow of 70,9 GPM of wA~er into the wa%er/~mmonia mixer'. m ~These v~lues are obtained from ~he table of capacitio~ published by the Cyrus Shank Company. m CAP.qC,iTiES DR~;NAG~- PIPES IN GALLONS PER MI AND FIXTURE UNIT OR CUBIC FE,--]~R MINUTE. Diameter I Fail in. I CaDacities ~,CLA L.L~ Velocity Full or '/2 Full in inches . per ff. G.P.M. I Fix. Units Ft. per Sec. 1/a 3.6 0.48 0.92 11/4'' 1/4 5.1 0.68 1.31 1/2 8.0 1.07 2.07 I 11.2 1.50 2.93 1/8 5.8 0.78 1.05 1 1/2" 1/'4 8.2 1.10 1.48 1/2 13.0 1.70 2.34 1 18.4 2.40 3.31 1/8 12.6 1.68 1.28 2" 1/4 17.6 2.25 1.80 1/2 27.8 2.70 ' 2.85 I 40.0 5.20 4.00 1/8 36.2 4.86 1.65 3" 1/,: 51.3 6.80 2.34 1/2 80.3 10.07 3.70 1 113.8 15.20 5.24 1/8 77.4 10.30 1.97 4" 1/4 109.6 14.80 2.79 1/2 173.6 23.10 4.42 1 254.4 32.70 6.25 1/8 138.6 18.50 2.25 5" 1/4 196.5 26.00 3.19 1/2 311.0 41.40 5.05 1 j 439.2 58.50 7.13 1/~ 221.4 2~.~0 2.51 6" 1/,~ 313.1 41.70 3.55 1/~, 494.8 65.90 5.61 1 699.4 93.20 7.93 1/8 328.5 42.80 2.73 7" "/4 465.6 62.00 3.87 1/2 735.1 98.00 6.11 I 1040.7 137.70 8.65 · 1/8 463.0 61.80 2.94 8" ~/' 656.0 87.40 4.16 't/= 1037.0 138.30 6.58 1 1468.0 195.60 9.31 . .i/~ :814.0 108.60 3.33 10"' Y,,. -.1149.0 153.20 4.70 Y2 1819.0 242.50 7.44 I 2572.0 343.00 10.52 % 1300.0 173.40 3.68 1~" 1/4 1838.0 245.00 5.20 Y2 2905.0 387.30 8.22 I 4034.0 537.80 11.62 TABLE BASED ON DARCY'S FORMULA FOR OLD CAST fRCN PIPE LINED WITH DEPOSIT AND FOR USE WHERE STATIC HE,iD IS NOT DESIRABLE. USE KUTTERS FORMULA WITH "N=0.015" FOR PIPES 14" DIA. ~24D OVER. HOOVER C5vMITTEE RPT. 7.9 "-~ FRANK JACKMAN REFRIGE TION, INC. I ~Y'~ ~& Design- Sales- Service-Installtion 1601~' Valley View, Santa Fe Springs, CA 90670 o Tel: (310) 921-1329 - Fax: (310) 926-5771 I ! i 6/14/93 IBarbara Brenner Hazardous.Materials Planning Technician 2130 "G" Street IBakersfield, CA 93301 iDear Barbara, Regarding the (2) items in your fax to me that Ipertain to UFC Article 80 please review the following: Item 1) IItem 2) We are not going to utilize a 2000 gal. storage tank after all. We intend to discharge directly into Ithe sewer as per my conversation with Tim Ryan. The design of the system other than the tank Iremains the same. iSincerely, IFJ/mef CITY of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON June 15, 1993 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Mr. Frank Jackman Frank Jackman Refrigeration 16017 Valley View Santa Fe Springs, CA 90670 Frank: The following items address the plan revisions for the Pepsi ammonia diffusion system noted in your letter of 6/14/93. It is our understanding that you now intend for the ammonia diffuser to discharge directly into the City sewer system. 1. Elimination of the storage tank will eliminate the UFC Article 80 requirements for secondary containment for storage of an irritant and for limit controls on a tank. 2. The Hazardous Materials Division will send Pepsi a copy of their hazardous materials management plan so that they can make the revisions necessary to reflect installation of the ammonia diffusion system. 3. Eric Poore, mechanical specialist, has reviewed the original plans. You will need to submit two sets of amended plans (without the tank) to the Bakersfield Building Department with an application for a building permit. Eric can be contacted at 805-326-3727 should you have further questions. 4. You still need to submit calculations that substantiate the system's capacity to provide two gallons of water per pound of ammonia to Chief Toler at the Fire Safety Control Division. Pepsi also needs to submit an application to the Fire Safety Control Division for a permit for a mechanical refrigeration system. Compliance with the other requirements on the plan check list dated June 3, 1993 will be verified by City of Bakersfield inspectors following installation. Chief Toler can be contacted at 805-326-3951 _should you have further questions. 5. The Wastewater Division will work with Pepsi and yourself directly regarding any permits modifications which may be necessary. ! ! i Let me know if I can provide any further assistance. Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: RalPh Huey Larry Toler Eric Poore Tim Ryan Bill Bently 07,'12/93 15:37 '~'805 326 0576 BFD F. AZ )IAT DIY ~002,'002 "WE CARE-" I FIRE O[PARTMENT 2~01 H STREET S. 9. JOHNSON July 12, 1993 BAKERS!::IELD..-9~[~ FIRE ChiEF .,~.326-3911 ...-'"' f ", Mr. Frank Jackman 16013 Valley View Santa Fe Springs, CA 90670 I Dear Mr. Jackman: I Upon review of your submittal for the ammonia diffuser system at Pepsi-Cola in Bakersfield, the following areas are still of concern. I 1. You use the letters ACFM. I can only surmise this refers to ammonia cubic feet per minute. If this is correct, tl~e conversion to 1,136 Ibs./min. would require a water flow of 2,272 GPM to attain I two gallons per pound of ammonia. The water system in this part of the city is not capable of that amount of flow, nor does it have a pressure of 00 PSI. Also you have failed to supply the city water I line size so we could substantiate what flow would be available. 2. These calculations are complex in nature, and it is next to I impossible for us to substantiate their correctness. With this in mind, I feel it necessary to require the calculations and the system design be reviewed and approved by a mechanical engineer I licensed in the State of California. If you wish to discuss this requirement with myself, Barbara Brenner from the Hazardous Materials Division and Deputy Chief Kelly, we would be happy to I meet with you. i Thank you. I Larry Toler Fire Marshal I LT/d IWDPRFFM 1 :PEPSICO FRANK CKMAN REFRIGE TION, INC. I "~'?~'~"~' Design · Sales · Service ° Installtion 16017 Valley View, Santa Fe Springs, CA 90670 · Tel: (310) 921:1329 · Fax: (310) 926-5771 m 6/17/93 m Chief Toler Bakersfield Fire Dept. m 2101 H Street Bakersfield, CA 93301 mDear Sir, Please review the calculations that I am providing myou regarding The Ammonia' Diffusion System. AMMONIA DIFFUSER DESIGN mThere are four emergency ammonia release valves that will be tied into the common header. Each valve will be 1" and will be connected t° the System via a 1" line. IThese lines and valves are designed for emergency use only. (2) will be considered high side lines operating at 175(PSI), and (2) will ba considered low side lines operating at 30(PSI). mDuring an emergency these valves are opened and the vapor is released to the diffuser. mPRESSURE ~he pressure in two high side lines cannot exceed 250% and the pressure in two low side lines cannot exceed 150% operating pressures. m We will be operat'ing ~ 175~/30~, but we will design flow based on maximum vessel ratings. m The releases at these pressures would be as follows: 250 PSI = 1136 ACFM or 931 lbs/min 150 PSI = 655 ACFM or 537 lbs/min mlines manifolded into one common header. The (4) together are The flow in the header does not equal the sum of all the flows, but 1.25% of the largest flow. m F LOW = .1420 ACFM or 1136 lbs/min. PIPE SIZING mThe header should'be sized based on the conservative inflow of two pipes at once. ASHRAE and The Uniform Fire Code state that the area of the header pipe should equal or exceed the combined area of the pipes flowing into it. m For this design we use the total cross-sectional area of two 1" pipes which is 0.0109 square feet. These one inch lines mwill tie into a 1~" header. The total area of the 1½" line FRANK CKMAN REFRIGE TION, INC. ~& Design · Sales · Se~ice · Installtion 16017 Valley View, Santa Fe Springs, CA 90670. Tel: (310) 921-1329 · Fax: (310) 926-5771 6/17/93 Page 2 equals 0.0122 square feet. The header size of 1½" is adequate to meet the criteria. The header also acts as' the diffuser for ammonia into a larger eight inch pipe. The header within the diffuser tank contains 400 -. 3/32" holes. This ensures the maximum water/ ammonia contact can occur to enhance absorption of the ammonia into the water. The total area of 400 such sized holes is square feet. This is greater than the pipe size and 0.019165 therefore adequate for flow. The six inch pipe is designed to reduce the velocity of the ammonia and enhance ammonia/water contact. The mixing chamber drains through a 4" opening and reduces to a 2" pipe into the sewer system. The area of the 2" pipe line is 0.0218 square feet. and is greater than the area of the 1½" header and the 400 openings or diffusing orifices and is therefore adequate. The total charge of the system is less than 1000~. At the estimated flow rate the~.system can be exhausted into the diffuser in less than 10 minutes. Inall actuality 300 gallons of water will absorb the 1000~ of ammonia vapor. However we are providing for (2) gallons of water for (1) pound of ammonia. Based on estimated pressure drops and system flows, we would need 200 GPM to provide the 2 gallons for every pound of ammonia. It is my understanding that the Bakersfield Fire Department can provide 300 GPM or more and at 80 PSI City water the line size will be adequate. Should you have any other questions, feel free to call any time. Frank Ja~km~an' FJ/mef i:::;,,:.' .... ' BAKERSFIELD' FIRE DEPARTMENT I~'" ' I YOU are h b required to znake the folloWing corrections ... - .' . .. · . .;.' .......~:~.~ ~-....:.. .. -:~..,~ OMPOFITANT. MESSAGI~ ,:,~,'r~ ~'/~/'7 / PHONE AREA CODE NUMBER EXTENSION' · .. .... .. - . ~ELE~ONED['~' ' . ~ LITHD ~N U,S~. TOPS ~ FORM 3002S _ Mp,ORTAI~IT MESSAG_I~ ~ M AR~ ~ NUMBER EXTENSION "WE CARE" October 8, 1993 FIRE DEPARTMENT 2101 FI STREET S. D. JOHNSON BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Mr. Frank Jackman Frank Jackman Refrigeration Inc. ' 16013 Valley View Santa.Fe Springs, CA. 90670 Dear Mr. Jackman: Per our conversation this morning I am attaching a copy of Section 63.108 of the 1991 Uniform Fire Code. This is the Fire Code that has been--adopted by the State of California as well as several other areas within the Western United States. The City of Bakersfield has also adopted this code by municipal ordinance.. As you can see this code requires that: .~ a) the diffusion system has a capacity of 2 gallons of water for each pound of ammonia, and '~' b) be.connected to a permanent water supply in addition to a fire department inlet connection. I do hope this satisfies your questions on this subject. If you have any further questions please don't hesitate to call. Sincerely yours, Ralph E. H~ey Hazardous Materials Coordinator REH/ed cc: Bill Bently, Pepsi , J. Hodes ~".I~POIPORTANT'MESSAGE) i PHONE. g ~7--~q 9~//70 AR~ ~D~ NUMBER ~ENSlON SIGNED · Ir'THO IN U.S~ TOPS ~ FORM 3002S June 3, 1993 PLAN CHECK RE: AMMONIA DIFFUSION SYSTEM - Pepsi Cola - Dr. Pepper Bottling Company, 215 East 21st Street, Bakersfield California, 93305- All installations to be per Article 63 of the "Uniform fire Code". Show proof that the tank is approved for this use. Obtain a permit, for "me..chanical refrigeration, syst`em" from the Fire Safety Control. Division of the BakerSfield Fire Department. Update the business plan for this facility with the Hazardous Materials Division of the Bakersfield Fire Department. Provide an approved card designating: a. instructions for suspending operation of the system in an emergency. b. name, address, and emergency telephone numbers to obtain emergency service. c. instructions to notify the Bakersfield Fire Department by dialing 9-1-1. Control box shall be iron or steel minimum 16 gauge provided with a hinged cover and lock and shall be provided with a.permanent label on the outside cover reading "FIRE DEPARTMENT - EMERGENCY REFRIGERANT CONTROL BOX" Fire Department shall be notified prior to activation of system. Plans shall be reviewed by the mechanical specialist of the City of Bakersfield Building Department. Diffusers shall be provided with a discharge line above the liquid refrigerant level on all operating pressure levels of the system. Provide detail of the specific ammonia diffuser used. Provide calculations that substantiate system has a capacity of 2 gallons of water per per pound of. ammonia. ' CITY. of BAKERSFIELD FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON BAKERSFIELD, 93301 FIRE CHIEF 326-39'11 . SITE PLAN REVIEW/PLAN CHECK " Re: Pepsi Co!a, 2'15 E. 21st St. Personnel at plant who will be trained to operate sYstem shall also be trained in use of self-contained breathing apparatus and should' have HAZWOPER (40 hour) training.. .Emergency. refrigerant control box should be located outside of building. Contact City of Bakersfield 'Wastewater to confirm .permission for this system to dumP into sewer. A durable"PlaCard"shall be Provided in the diCect-Proximity of the fire department connection stating the gallons per minute needed in a situation Where the City water main is not operating. Date Typed: 8/31/9.3 Typed By: 'dlf cC: Ralph Huey/City Fire' Department, Hazardous Materials Division WDPRFPLANSCH ECK:215E21 ST cITy of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON June 15, 1993 BAKERSFIELD, 9330~ FIRE CHIEF 326-3911 Mr. Frank Jackman Frank Jackman RefrigeratiOn 16017 Valley View Santa Fe Springs, CA 90670 Frank: The following items address the plan revisions for the Pepsi ammonia diffusion system noted in your letter of 6/14/93. It is our understanding that you now intend for the ammonia diffuser to discharge directly into the City sewer system. 1. Elimination of the storage tank will eliminate the UFC Article 80 requirements for secondary containment for storage of an irritant and for limit controls on a tank. 2. The Hazardous Materials Division will send Pepsi a copy of their hazardous materials management plan so that they can make the revisions necessary to reflect installation of the ammonia diffusion system. 3. Eric Poore, mechanical specialist, has reviewed the original plans. You will need to submit two sets of amended plans (without the tank) to the Bakersfield Building Department with an application for a building permit. Eric can be contacted at 805-326-3727 should you haye further questions. 4. You.. still need to submit calculations that substantiate the system's capacity to provide two gallons of water per pound of ammonia to'Chief Toler at the Fire Safety Control Division. Pepsi also needs to submit an application to the Fire Safety Control Division for a permit for a mechanical refrigeration system. Compliance with the other requirements on the plan check list dated June 3, 1993 will be verified by City of Bakersfield inspectors following installation. Chief Toler can be contacted at 805-326-3951 should you have further questions. 5. The Wastewater Division will work with Pepsi and yourself directly regarding any permits modifications which may be necessary...,. Let me know if I can provide any further assistance. Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: RalPh Huey Larry. Toler Eric Poore Tim Ryan Bill Bently FRANK JACKMAN REFRIGERATION, INC. Design · Sales * Service ° Installtion 1601] Valley View, Santa Fe Springs, CA 90670 ° Tel: (310) 921-1329 · Fax: (310) 926-5771 6/17/93 Chief Toler Bakersfield Fire Dept. 2101H Street Bakersfield, CA 93301 Dear Sir, Please review the calculations that I am providing you regarding The Ammonia' Diffusion System. AMMONIA DIFFUSER DESIGN There are four emergency ammonia releasevalves that will be tied into the common header. Each valve will be 1" and will be connected to the System via a 1" line. These lines and valves are designed for emergency use only. (2) will be considered high side lines operating at 175(PSI), and (2) will be considered low side lines operating at 30(PSI). During an emergency these valves are opened and the vapor is released to the diffuser. PRESSURE The pressure in two high side lines cannot exceed 250~ and the pressure in two low side lines cannot exceed 150~ operating pressures. We will be operating ~ 175~/30~, but we will design flow based on maximum vessel ratings. The releases at these pressures would be as follows: 250 PSI = 1136 ACFM or 931 lbs/min 150 PSI ~ 655 ACFM or 537 lbs/min The (4) lines are manifolded together into one common header. The flow in the header does not equal the sum of all the flows, ~ but 1.25% of the largest flow. FLOW = 1420 ACFM or 11~6 lbs/min. PIPE SIZING ~\~ The header should be sized based on the conservative inflow of two pipes at once. ASHRAE and The Uniform Fire Code state that the area of the head~r?~ipe should equal or exceed the combined area of the pipes flowing into it. For this design we use the total cross-sectional area of two 1" pipes which is 0.0109 square'feet. These one inch lines will tie into' a 1½" header. The total area of the 1½" line FRANK JACKMAN REFRIGERATION, INC. Design · Sales ° Se~ice ° Installtion 1601] Valley View, Santa Fe Springs, CA 90670 · Tel: (310) 921-1329 · Fax: (310) 926-5771 6/17/93 Page 2 equals 0.0122 square feetl.' The header'size of. 1½" i~ a~quate to meet the criteria. The header also acts as the diffUser for ammonia into a · larger eight inch pipe. The header within the diffuser tank ... ?contains 400 - 3/32".hol'es. This ensures the maximum water/ ammonia 60~act can occur to enhance absorption of the ammonia into the water. .The total area of 400 such sized holes is ,0.019165 square feet. This is greater than the pipe.size and ~t~'-araf2r therefore adequate for flow. The six inch pipe is designed to reduce the velocity of the ammonia and enhance ammonia/water contact. The' mixing chamber drains through a 4" opening and reduces to a 2" pipe into the sewer system. The area of the 2" pipeiline is 0.0218 square feet. and is greater than the area of the 1½" header and the 400 openings or diffusing orifices and is therefore adequate. The total charge of the system is less than 1000~. At the estimated flow rate the system can be exhausted into the diffuser in less than 10 minutes. Inall actuality 300 gallons of water will absorb the 1000% of ammonia vapor. However we are providing for (2) gallons of water for (1) pound of ammonia. Based on estimated press6re drops and system flows, we would need 200 GPM to provide the 2 gallons for every.pound of ammonia. It is my Understanding that the Bakersfield Fire Department can provide 300 GPM or more and at 80 PSI City water the line size will be adequate. Should you have any other questions, feel free to call any time. Sincerely, FJ/mef CITY of BAKERSFIELD · "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON July 12,1'993 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Mr. Frank Jackman Frank Jackman Refrigeration Inc. 16013 Valley View Santa Fe Springs, CA 90670 Dear Mr. Jackman: Upon review of your submittal for the ammonia diffuser system at Pepsi-Cola in Bakersfield, the following areas are still of concern. 1. You use the letters ACFM. I can only surmise this refers to ammonia cubic feet per minute. If this is correct, the conversion to 1,136 lbs./min, would require a water flow of 2,272 GPM to attain two gallons per pound of ammonia. The water system in this part of the city is not capable of that amount of flow, nor does it have a pressure of 80 PSI. Also you have failed to supply the city water line size so we could substantiate what flow would be available. 2. These calculations are complex in nature, .and it is next to impossible for us to substantiate their correctness. With this in mind, I feel it necessary to require the calculations and the system design be reviewed and approved by a mechanical engineer licensed in the State of California. If you wish to discuss this requirement with myself, Barbara Brenner from the Hazardous Materials Division and Deputy Chief Kelly, we would be happy to meet with you. Thank you. Larry Toler Fire Marshal LT/d WDPRFFM1 :PEPSICO FRANK JACKMAN REFRIGERATION, INC. Design · Sales · Service ° Installtion 1601.~ Valle~ View, Santa Fe Springs, CA 90670 · Tel: (310)' 921-1329 ° Fax:.(310) 926-5771 6/17/93 Chief Toler Bakersfield Fire Dept. 2101H St'reef Bakersfield,· CA 93301 Dear Sir, Please review the calculations that I am providing you regarding The Ammonia' Diffusion System. AMMONIA DIFFUSER DESIGN There are four emergency ammonia releas~valves that will be tied ~nto the common header. Each valve will be 1" and will be connected to the Syste~ via a 1" line. '·,'These lines and valves are designed for emergency use only. (2) .will be considered high side lines operating at 175(PSI),. and (2) will be considered low side lines operating .at 30(PSI). During an emergency these'valves are opened and the vapor is released to the diffuser. PRESSURE The pressure in two ,high· side lines cahnot exceed 250~ and·the pressure in two low side lines cannot exceed I50~ operating pressures. We will be operating ~ 175%/30%, but we will design flow based on maximum vessel ratings. . · I~~ . ' "~ The reiease~' at these pressures would be."as follows:. · .-:/250 PSI ~-l136:A~FM or 931 lbs/min ' ~'" .... ~/. i50 PSI = 6~5.-ACFM or 537'lbs/min ' ' \ The (4) lines are manifolded together into one common' header. · \., The ~lo~._in the header 'does not equal-the sum of all the flows, '! ." ';,,'~,;~ut~ i'.~5~./Of the larges~ flow. ' . <f¢'5c~-' ~-~Low_= ·!420 ACFM or ll,~6'lbs/min. PIPE SIZING "k\"% P) Th~header should be sized based on the conservative inflow of two pipes at once. ASHRAE and The Uniform Fire Code state that the area of the header pipe should equal or exceed. the combined area of the pipes flowing into it.--~%{ For this design we use the total cross-sectional area of. two 1" pipes which is 0.0~,;09 square feet. These one'inch lines will tie into a 1½" head~. The total area 'of the-1½" line / FRANK JACKMAN REFRIGERATION, INC. ~3~'~ Design · Sales · Se~ice · Installtion 1601] Valley View, Santa Fe Springs, CA 90670 · Tel: (310) 921-1329 ~Eax:.(31.~0)~2~-~77.___!.l L- 6/17/93 Page 2 equals 0.0122 square feet. 'The header size of I½" is adequate to meet the criteria. The header also.acts as the diffuser for ammonia.into a. larger eight inch pipe. The header within the diffuser tank -contains 400 -'3/32" holes. This ensures the maximum water/ ammonia Contact can occur to 'enhance absorption of the ammonia. into the water. The total area of 400 such sized holes is L~/~0.019'165. square feet. This is greater than the pipe siZe and 'therefore adequate for flow. The six inch pipe is designed to reduce the velocity of the ammonia and enhance ammonia/water contact. The mixing chamber drains through a 4"-oPening and reduces to'a 2" pipe into the sewer system. The area of the 2" pipe line is 0.0218 square feet. and is greater than the area of t.he 1½" header and the 400 openings' or diffusing orifices and is therefore adequate. The total charge of the system is less than 1000~. At the estimated. flow ra~e tke syste~ caj~ b~ exha~.st_ed i3kt_o~t/~e d/~fuser in l~ss than 10 minutes..Q$;~ ~9 ~ ~0~ /Q~'~I~¢~actuality 300 gallons.of wate will r absorb the 1000~ (of ammonia vapor. However we are providing for (2) gallons of/ ~er for (1) pound of ammonia. /~ Based on ear,met'ed pressure drops and system flows, we ~ would need 200 GPM'to provide the 2 gallons for every pound 'of ~ ammonia. It is my Understanding that the Bakersfield Fire"' % Department can provide 30D GPM or more and at 80 PSI City wa'ter 4the 1.1ne size will be adequate. / " .$hould..~o'u have any/other questions, feel free to call any time. __~ . . ' Sincerely, Frank Jack, an FJ/mef ' . ~.FRANK ~ACKMAN REFRIGE~TION, INC. Design · Sales .° Servia · Instalition 1601.,;7 Valley View, Santa Fe Springs, CA 90670 ° Tel: (310) 921,1 329 · Fax: (310) 926-5771 FORM El0 (7/87) -~~ FRANK ~IIACKMAN REFRIGE TION, INC. Design · Sales · Service · Installtion 1601~' Valley View, Santa Fo Springs, CA 90670 · Tel: (310) 921-1329 · Fax: (310) 926-5771 FORM El0 (7/871. '~,~ FRANK JACKMAN REFRIGERATION; INC. Design · Sales · Service · Installtion 601.= Valley View, Santa Fe Springs, CA 90670 · Tel: (310) 921-1329 · Fax: (310) 926-5771 d.~ ' CITY OF BAKERSFIELD FIRE DEP-X~TNLENT. [[AZARDOUS M_ATERIAI,S D1-VISION 2130 "G" Street " Bakersfield, Ca. 93301 ~ /I /~ , Fax Phone (805)326-0576 ./--~-~ '_~. ' ', ~/ ..,,~) PLEASE ROUTE AS SOON AS POSSIBLE TO: Fax No. Sending Message to: FRO M: Number of Pages (including cover sheet): ~_~ Description of Materials Sent/Special Instructions: CITY of BAKERSFIELD O~ober 8, 1993 FIRE DEPARTMENT 2101 H STREET S. O. JOHNSON BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Mr. Frank Jackman Frank Jackman Refrigeration Inc. 16013 Valley View Santa Fe Springs, CA 90670 Dear Mr. Jackman: Per our conversation this morning I am attaching a copy of Section 63.108 of the 1991 Uniform Fire Code. This is the Fire Code that has been--adopted by the State of California as well as several other areas within the Western United States. The City of Bakersfield has also adopted this code by municipal ordinance. As you can see this code requires that: a) the diffusion system has a capacity of 2 gallons of water for each pound of ammonia, and b) be connected to a permanent water supply in addition to a fire department inlet connection. .I do hope this satisfies your questions on this subject. If you have any further questions please don't hesitate to calL. Sincerely yours, Ralph E. Huey Hazardous Materials COordinator REH/ed cc: Bill Bently, Pepsi J. Hodes ':WE CARE" October 8, 1993 FIRE DEPAR~DMENT 2101 FI STREET S. D. JOHNSON BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Mr. Frank Jackman Frank Jackman Refrigeration Inc. 16013 Valley View Santa Fe Springs, CA. 90670 Dear Mr. Jackman: Per our conversation this morning I am attaching a copy of Section 63.108 of the 1991 Uniform Fire Code. This is the-Fire Code that has been-' adopted by the State of California as well as several other areas within the Western United States. The City of' Bakersfield has also adopted this code by'municipal ordinance. As you can see this code requires that: a) the diffusion system has a capacity of 2 gallons of water for each pound of ammonia, and ? b) be connected to a permanent water Supply in addition to a fire department inlet connection. I do hope this satisfies your questions on this subject. If you have any further questions please don't hesitate to call. Sincerely yours, ¢~aiPh 5. Uuey Hazardous Materials Coordinator REH/ed cc: Bill Bently, Pepsi ,' -J. Hodes CITY of BAKERSFIELD "WE CARE" FIRE OEPARTMENT 2101 'H STREET S. D. JOHNSON June 15, 1993 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Mr. Frank Jackman Frank Jackman Refrigeration 16017 Valley View Santa Fe Springs, CA 90670 Frank: The following items address the plan revisions for the Pepsi ammonia diffusion system noted in your letter of 6/14/93. It is our understanding that you now intend for the ammonia diffuser to discharge directly into the City sewer system. 1. Elimination of the storage tank will eliminate the UFC Article 80 requirements for secondary containment for storage of an irritant 'and for limit controls on a tank. 2. The Hazardous Materials Division will send Pepsi a copy of their hazardous materials management plan so that they can make the revisions necessary to reflect installation of the ammonia diffusion system. 3. Eric Poore, mechanical specialist, has reviewed the original plans. You will need to submit two sets of amended plans (without the tank) to the Bakersfield Building Department with an application for a building permit. Eric can be contacted at 805-326-3727 should you have further questions. 4. You still need to submit calculations that substantiate the system's capacity to provide two gallons of water per pound of ammonia to'Chief Toler at the Fire Safety Control Division. Pepsi also needs to submit an application to the Fire Safety Control Division for a permit for a mechanical refrigeration system. Compliance with the other requirements on the plan check list dated June 3, 1993 will be verified by'City of Bakersfield inspectors following installation. Chief Toler can be contacted at 805-326-3951 should you have further questions. 5. The Wastewater Division will work with Pepsi and yourself directly regarding any permits modifications which may be necessary. Let me know if can provide any further assistance. Sincerely,. Barbara .Brenner Hazardous Materials Planning Technician cc: Ralph Huey Larry Toler Eric Poore Tim Ryan Bill Bently CITY of BAKERSFIEL'D "we c,4Re" FIRE DEPARTMENT 2101 H STREET s. c). JOHNSON May 21 1993 BAKERSFIELD. 93301 FIRE CHIEF ' 326-3911 Mr. Bill Bently Pepsi Cola Bottling Co. 215 E. 21 st Street Bakersfield, CA 93305 Per your request, Bakersfield Fire Department will extend the risk management and prevention program (RMPP) implementation date for Pepsi from May'.27, 1993 to July 15, 1993. This extension is being granted specifically to allow extra time to complete the installation of the ammonia diffusion system. However, all aspects of the RMPP should be implemented by July 15, 1993. I will contact you to schedule an inspection to verify. RMPP implementation later this summer. Please call me at 326-3979 if you have any questions or if I can_ provide assistance. Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey. Kevin Phillips Frank Jackman PEPSI / · t :', March 23, 1993 RECEIVED Barbara Brenner i ,PR :6 1993 City of Bakersfield Fire Department 2101 H Street HAZ. MAT. DIV. Bakersfield, CA 93301 Barbara: As discussed, our ammonia tank bracing project was completed during Mid January. The attached engineering plan describes the technical requirements of the project and the summary below lists the activities that took place to complete construction: 1. After structural evaluation by Engel & Company, the engineering plan dated 12- 22-92 was completed and submitted to Bakersfield City Fire and Building Departments for review Cost: $980.00 2. Building Department Plan-Check Staff approved the engineering plan, issuing a building permit on 1-7-93. Cost: $163.35 3. After welding contractor bid review, UCl Construction was selected and construction was completed on 1-15-93. Cos1:$1,750.00 4. Building Inspector reviewed completed construction, approved work and gave final permit status on 1-28-93. TOTAL PROJECT COST: $2,893.35 Please call if you have further questions or concerns. Sincerely, Kevin Phillips KP:dh cc: Tony Engel Bob Coleman DOT.93\F !REDEPT.KP 215 East 21st Street · Bakersfield, California 93305 ° (805) 327-9991 'I ISPECTION REC I RD CITY BUILDING DEPARTMENT BAKERSFIELD, CALIFORNIA POST In a Conspicuous Place at the Job'Site for Duration of Work. DO NOT remove this Card until Final Building Inspection has Been Signed.. DO NOT cover up any work until inspected and signed by Inspector Phone 326-3728 Inspector Inspector INSPECTION & Date INSPECTION & Date STRUCTURAL PLUMBING MECHANICAL ELECTRICAL ALL IMPROVEMENTS SHALL BE INSTALLED, COMPLETED AND ACCEPTED BY THE PUBLIC WORKS DEPARTMENT PRIOR TO OCCUPANCY OF ANY .FINAL PLUMBING FINAL MECHANICA~ FINAL ELECTRIC "~ FINAL BUILDING & SITE WOI; ' Building Address '2~/..(-- ~ ~ / 5f '~/~/1/~ ~'~/P~'~/- ~ /~~ · .--, · , /" ~l~g. Per~it No. Tract Block Lot Elect. Permit· No. ~--/~¢ (: Arch.-Eng. Plumb. Permit No. Owner ~/_~E]2,~ j Mech. Permit No. Contractor CITY of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON January 11, 1993 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Kevin 'Phillips Pepsi Cola Bottling Co. 215 E. 21 st Street Bakersfield, CA 93305 Kevin: ' The Bakersfield Building Department is currently reviewing the plans to upgrade the supports of four ammonia vessels in the Pepsi Plant. Because the blueprints do not contain a legend, it is difficult to tell which vessels are under consideration. Please have the engineering firm prepare a brief statement outlining the scope of the work performed and the findings of their review. This request is consistent with the requirements outlined in item 2 of my. letter dated 5-27-92. Please submit this summary of the structural engineering review to the Hazardous Materials Division by February 11, 1993. Sincerely, Barbara Brenner 'Hazardous Materials Planning Technician cc: .Ralph Huey 1501 TRUXTUN AVE BAKERSFIELD, CA 93301 BUILDING DEPARTMENT PERMIT INFO Permit No..: 93-00074 Applied..: 01/07/1993 Permit Type: COMA Approved.: 01/07/1993 Type ....... : ALT Completed: Status ..... : APPROVED To Expire: 07/06/1993 'LOCATION Job Address: 215 E 21ST ST Location...: Description: TANK SUPPORT AND BRUCING Tr/No/Lot..: TR Parcel...: 016-130-11-005 Zone.- ...... : M1 SPR No...: School Dist: Park Dist: Cond Sq Ft.: CONSTRUCTION Occ Class..: B2 Occ No...: Type Const.: V-N Code ..... : 1991UBC Fire Sprlk.: N 37 pEOpLE Owner ...... : PEPSI-COLA BOTTLING CO Phone No.: Applicant..: PEPSI-COLA BOTTLING CO Phone No.: Arch/Engr..: Phone No.: ContraCtor.: Phone No.: Cont Lic No: Exp Date.: Cont Addr..: FEES Plan Check.: 64.35 Total Sq Ft...: Building...: 99.00 Bldg Valuation: 8,000.00 Mechanical.: .00 Mech Valuation: .00 Plumbing...: .00 Plmg Valuation: .00 Electrical.: .00 Elec Valuation: .00 Fire Sprlk.: .00 Fire Sprlk Val: .00 Bond ........ : .00 Bond Valuation: .00 School Fee.: .00 Tot Valuation.: 8,000.00 Park Fee...: .00 Tot Calc Fee..: 163.35 Habitat Fee: .00 Additonal Fee.: .00 Special Ins: .00 Tot Permit Fee: 163.35 Additional.: .00 Payments ...... : 163.35 Double Fee.: .00 Balance Due...: .00 S.M.I. Fee.: .00 DECLARATIONS CALL FOR INSPECTION Pe~nit is issued in accordance with all applicable Federal, State and Local 24 Hour Recorder Number (805) 326-3728 O~dinances. The permittee has properly signed and dated the reverse side of Ibis ~. Please state ~he Permit Number,. the Job Address, er~d the Type of Inspection. Request for inspections should be This permit expires after 180 days of Inactivity. mede at least twenty-four hours in edvance. ..... I have reviewed the above application, and find it to be correct/complete: Inspectors office hours are: 8:00 - 8:30 AM and 1:00 - 1:30 PM Permittee: Date: · CITY of BAKERSFIELD '" "WE CARE" FIRE DEPARTMENT 2101 H STREET S O. JOHNSON October,__~7, 1992 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Kevin Phillips Pepsi Cola Bottling Co. 215 E. 21 st Street Bakersfield, CA 93305 Kevin: I have reviewed your request for an extension of the completion date for several of Pepsi's RMPP implementation items. The structural evaluation was to have been submitted by August 31, 1992. Due to the change of ownership of the company we will agree to an extension of this date. December. 28, 1992 is 90 days from the date of your request and will serve as the date by which the structural evaluation and recommendations should be submitted for review. The Bakersfield Building Department is responsible for enforcement of the Correction Notice regarding the emergency exiting. The notice was dated 4-21-92. I do not know how long the building department allows for installation. You should contact the Building Department regarding an immediate extension for the exiting requirements. The emergency exiting, the diffusion system installation and secondary containment uPgrade are also RMPP implementation items which will have to be complete by May 27, 1993. The entire RMPP must be implemented by the one year anniversary of it's completion (5-27-93). I understand your concern regarding the cost of these projects. However, all of these code requirements were enforce at the time the affected systems were installed. Be sure that all future projects are properly permitted and finaled in order to avoid · unexpected retrofit expenses. Please call me if I can be of any assistance. Sincerely, Barbara Brenner Hazardous Materials Planning Technician Cc: Ralph Huey September 28, 1992 .. RECEIVED Barbara Brenner City of Bakersfield 'OCT 0 8 1992 2101 H Street Bakersfield, CA 93301 HAT. ~A~T. DIV. Barbara, As we discussed over the phone last week, the Lindsey Family recently announced their intent to sell the company, ending their franchise ownership and transferring the business to the parent company, Pepsico, Inc. The sale makes it necessary to request a 90 day extension on further RMPP tasks so that we can complete the transition phase, evaluate future production plans and understand possible consolidation of production activities. Your cooperation in this matter will be appreciated. I have included some of the cost estimates related to RMPP implementation that will be part of the decision making process with Pepsico: 1. Expenses to Date: a. WZI consulting fees, RMPP & HAZOP preparation 16,423.00 b. City Fire DepartJaent, Agency oversight fees 1,912.50 c. Engineering Consultation, Exit Revision Project 1,375.00 d. Second Self Contained Breathing Apparatus 800.00 Total paid to date 20,510.50 2. Estimated Expenses to complete implementation requirements: a. Exit Revision Construction Project 24,950 b. A~m~onia Diffusion System Installation 22,000 c. Structural Evaluation of Vessels 1,200 (Does not include cost of construction upgrades) d. Sulfuric Acid Secondary Containment Upgrade 1,175 Total Estimates 49,325 3. Total RMPP expense including implementation estimates 69,835.50 · :;~- 215 East 21st Street, Bakersfield, California 93305 · 805/327-9991 · WATTS 1-800-339-7377 If you know of other requirements that will impact capital spending we would appreciate hearing from you as soon as possible. The cost of compliance needs to be clearly defined so that we can make informed business decisions and plan the future of our production operation. Please call if you have further input or comments. I sincerely hope the cost of compliance will not lead to lost jobs and relocation of another -indu~try-'from-the area. Kevin Phillips Operations Manager cc: Bob Coleman BiI1 Bentiey Steve Aiman · · .Few changes exPeCted 'in shift to corpOrate oWnerShip ", By.JoE D. STEVENSON i 'peak 'payroll Of about 900 peopl~ with 250 ees is unknown. '"J ' · · ' ~ ~ '$~ni?~ business writer ' employed in.Kern County. . "They (the emplOyees) have done a It's business as usual at Pepsi-Cola Bob Coleman continues as general mun, superior job. They re,ally honed in on what's Bottling Co. of Bakersfield, but the 40-year- ager of.the Bakersfield operation. "The' important for the buMness," he said. old bottling and distribution firm now oper- transition has been very smooth," he said. In 1952 Bud Lirldsey was running a pe sic.o t'akes over .I Cai pepsi .'-'Cola plant ' "I think, and I'm speaking for myself and the majority of employees, that the employees look on this as a real opportuni- ty. The opportunities have expanded 100- fold. "It was great working for the Lindsey family. If I worked for a family, they would be the ones I would want to work for .... but Pepsi is a bigger comPany with a lot of · opportunities!' ... · "There are no negatives that I've heard; Our turnover was. low and people enjoyed working for the Lindseys. If I had to sum it up, I'd say I enjoyed working for the Lindseys, but now I see it as more opportu- nities for everybody." Pepsi-Cola spokesman Andrew Giangoia said the acquisition "makes sense in our overall business plan.'.' Giangola' pointed out that 52 percent of the Pepsi operatiofis throughout the country are company-owned with the remaining 4~ percent franchises. "We don't see that the change will impact consumers," he said. He said no immediate changes are planned, and the future impact on employ- sardine cannery near.' Port Hueneme, when he was asked by Rocky Mountain Beverage Co. to take over its faltering distributorship in Kern County. A year later heI bought the franchise. The operation at the time included a Quonset hut and two! trucks. Jim 'Lindsey, a ~raduate of California .State Pol~echnic Uriiversity, San Luis Ob- ispo, ~]0ined his father in 1968 and was named president in ,i975.' Nine years ago pepsi-cola Bottling Co. of Bakersfield 'bougtit the San Diego fran- chise and the plant lin BrawleY. Six years ago it acquired the tri-county franchise on the Central Coast a~d began operating the entire operation as 6'hannel Islands Bever- age Group. Over the years involved in numero projects. · · In 1988,'Baker: franchises to receiv community service used to support a sl Brock Museum. ~he company has been ~s community service ifield' was one of 10 .~ a Pepsi USA $10,000 grant. The grant was ~ecial-program at Lori ates as a unit of Pepsi-Cola Co. of Somers, N.Y., the soft-drink subsidiary of Pepsico. Channel Islands Beverage Group, which Jim "Bud" Lindsey and his son, James B. "Jim" Lindsey Jr., developed from the 1953 purchase of a' faltering Bal~ersfield bottling company, has been sold to Pepsico. · The sale .was.completed Sept. 25 without ceremony,.said .~im. Lindsey, president of. Channel Islands.~',: ' ':' ' -' Neither,, Lindsey nor PepsiCola repre-. sentatives' .would· disclose the. purchase price.' '"" Channel Islands Beverage Group includ- '.-ed Pepsi-COla franchises in Bakersfield, and in the counties of Ventura, Santa Barbara, San Luis Obispo,'San Diego and Imperial. The company bottled and distributed Pepsi products from Brawley to Santa Maria and throughout Kern County. Channel Islands had bottling plants in Bakersfield and San Diego, and distribution. warehouses in Brawiey and Santa Maria. Lindsey said,~there were no personnel changes as a result of the change of · ownership. The operation has a seasonal DIGEST Mall grants extension THE CALIFORNIAN Channel 'Islands-Beverage Group which includes bOttling operations in Bakersfield, has been sold to Pepsi-Cola Co. of Somers, N.Y., the soft-drink subsidiary of Pepsico. CI'T Y .o f BAKER SFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON September 15, i992 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Kevin Phillips Pepsi Cola Bottling Co. 215 E. 21st Street Bakersfield, CA 93305 Keri n: The Bakersfield Building Department has not received the structural evaluation of the bracing of the ammonia vessels at the Pepsi plant. Per the RMPP implementation schedule, the structural .evaluation was to have been completed and submitted for review in August of 1992. I have enclosed a copy of my letter which outlined these requirements. Please let me know as soon as possible what the status of the structural review is. I can be reached at 326-3979. Sincerely, Barbara Brenner Hazardous Materials Planning Technician 'cc: Ralph Huey CITY-of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON June 19,1992 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Mr. James B. Lindsey, Sr. Pepsi Cola BottlingCompany 215 E. 21st Street ' Bakersfield, Ca. 93305 Dear Mr. Lindsey~ You have indicated in your Risk Management and Prevention Program that if a chemical release occurs at your facility your employees are trained to initiate an emergency response to that incident. Please forward the names of the employees who. have been 'trained for this activity, a brief description, by the individual, of his or her training level, hours of training and response capability, and a copy of the documentation or certificatibn of that training. This information'will of course, be essential in the unlikely event of an incident at your facility. Please forward that information to our office by July 27, 1992. If you have any questions or need assistance please do not hesitate to call. Sincerely Yours, Ralph E. Huey Hazardous Materials Coordinator REH:vp. cc: Safety Coordinator PROOF of Sto~-y '~7630' Request'ed by tOJANELL (~F603) on 5/28/92 9:38:17 Ad ~ U7630 Ad type V Basket CENSOR Entel-ed By IOJANELL On 5/28/92 at 9:38 Fo~- [OJANELL Account 32639~IBAK Clas~ ~ 397 Na~e DEPARTMENT BAKERSFIELD FIRE Ph~ (805~ 32639~1 Add~' 2101 H STREET GB/PO LEGAL City BAKERSFIELD State CA Zip 93501 Ad Sta~-t 6/01/92 Tiaes I Stop 6/01/92 Rate LL 19 Billing lines 1.33 Inches ~otal ~17. 10 Adcost 17. kNff [NPU~ TEXT . 4 been .p~-epaeed by [he P'epsi-~al.a .5 .Bo~,t]i~g ~. 7 RMPP desc~-ibes, p~og~ams and 8 co~[~ol s desi g~ed haza-rdous matepial accident. ~his RMPP ~ill be available, f~ public- pevie~ fo~ the ~ext 45 days a[ the Bakepsfield Fipe Depapt~e~t, 13 ~aza~d~us Mate~ials Division ]4 G St., Bake~sfie!d~ CA ~3301~ C~n- t~et B~r~apa J~ne 1, 1992 PROOF of Story '~7630'. Requested by IOJANELL Entered By 10JANELL On 5/28/92 at 9:38 For IOJANELL Account 3263941BAK Class 397 '"-'*J'Ci'ty BAKERSFIELD State CA Zip 93301 Ad Sta~'t 6/01/92 Ti~es I Stop 6/01/92 Rate I ' (SiYLlpu, lgl <ql> ..... ' RMPP describes programs and 9 haza~-dous mate?ial accident. This 10. RMPP ~ill be available fop public pevie~ fop the ~e~ 45 days a~ the '13 Haza?dous Mate~ials Division 2130 -' 15 tact Ba~baea B~enne~ fop info~-~a- 17 June l~ 1992 (7630) (ep>. .. ..... Add~ ~lOt H STREET G6/PO LEGRL '.""'~ J City BAKERSFIELD State CA Zip 93301 Ad Sta~-t 6/O1/9~ Tiaes [ Stop ~/O1/9~ Rate El ~ ~ (STYL) pu~ lgl (q]) ' [ " *' been p~ePa~ed by the Pe'psf-Cela L,~,.L,L.' .-. 7 RMPP descmibes p~°g~aDs and -~,,~ 8 .cont~als designed to p~event a .13 ~evie~ fop the ne~[' 45 days at the '"' 15 tact Barbara Bpeune~ fo~ infoe~a- CITY of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON BAKERSFIELD. 93301 FIRE CHIEF 326-3911 MAY 27, 1992 MR' KEVIN PHILLIPS: NOTICE OF VIOLATION AND SCHEDULE FOR COMPLIANCE THE FOLLOWING UNIFORM FIRE CODE VIOLATIONS HAVE BEEN IDENTIFIED AT PEPSI COLA, LOCATED AT 215 E. 21st STREET~ BAKERSFIELD, CA 93305. 1. THE AMMONIA REFRIGERATION SYSTEM HAS NOT BEEN PROVIDED WITH AN AMMONIA DIFFUSION SYSTEM. VIOLATION OF UFC 63.108 (a) Emergency Ammonia Diffusion Systems. 1. General. Ammonia refrigeration Systems shall be provided with an approved system for promptly and safely removing the ammonia refrigerant in the event of an emergency. Such emergency systems shall discharge into an approved water storage tank, water basin or diffuser, having a capacity of 2 gallons.of water for each pound of ammoffia. The'above violations must be corrected by May 27, 1993. The ammonia diffusion system must meet the provisions of Article 63 of the Uniform Fire Code. Plans should be submitted to and approved by the Bakersfield Fire Safety Control Division prior to performing any installation work. A copy of the full requirements of the Uniform Fire Code- Article 63 is attached. Failure.to correct .these violations will result in enforcement action. The Fire Department will schedule a re- inspection of your facility to verify compliance. If you' have any questions regarding this notice, please contact Barbara Brenner at 326-3979. Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey, Hazardous Materials Co'ordinator Larry Toler, Fire Marshal Michael Allford, Deputy City Attorney CITY of BAKERSFIELD ~ "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON May 27, 1992 BAKERSFIELD, 93301 FiRE CHIEF 326-3911 Karl Luff Luft Environmental Consulting · 3701 Pegasus Dr., Suite 121 Bakersfield, CA 93308 Karl: A Risl~ Management and Prevention Program (RMPP) has been prepared by the . Pepsi-Cola Bottling Co. located at 215 East 21st St., Bakersfield, CA. The RMPP describes programs and controls designed to prevent a hazardous material accident. This RMPP will be available for public review for the next 45 days at the Bakersfield Fire Department, Hazardous Materials Division 2130 G St. Bakersfield, CA 93301. , If you need any further information regarding this legal notice, please call me.at 326-3979. Sincerely, Barbara Brenner Hazardous Materials Planning Technician .cc: Ralph Huey CITY of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET. S. D. JOHNSON . May 27,1992 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Prindpal Community School 307 E. 21st St. Bakersfield, CA 93305 Dear Sir: A Risk Management and Prevention Program (RMPP) has been prepared by the .Pepsi-Cola Bottling Co. located at 215 East 21st St., Bakersfield, CA. The RMPP describes programs and controls designed to prevent a hazardous material accident. This RMPP will be available for public review for the next 45 days at the Bakersfield Fire Department, Hazardous Materials Division 2130 G St. Bakersfield, CA 93301. If you need any further information regarding this legal notice, please call me at 326-3979. I' Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey CITY of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON May 27,1992 BAKERSFIELD,.93301 FIRE CHIEF 326-3911 Principal Special Services School 815 Eureka St. Bakersfield, CA 93305 Dear Sir: A Risk Management and Prevention Program (RMPP) has been prepared' by the Pepsi-Cola Bottling Co. located at 215 East 21st St., Bakersfield, CA'. The RMPP describes programs an~l controls designed to prevent a hazardous material accident. This RMPP will be available for public review for the next 45 days at the Bakersfield Fire Department,. Hazardous Materials Division 2130 G St. Bakersfield, CA 93301. If you need any further information regarding this~legal notice, please call me at '326_3979. Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey i "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON May 27, 1992 BAKERSFIELD, 93301 FiRE CHIEF 326-3911 Principal Our Lady of Guadalupe School 601 E. California Ave. Bakersfield, CA 93307 Dear Sir: A Risk Management and Prevention Program (RMPP) has been prepared by the Pepsi-Cola Bottling Co.'located at 215 East 21st St.., Bakersfield, CA. The RMPP describes progi~ams and controls designed to prevent a hazardous material accident. This RMPP will be available for public review for the next 45 days at the Bakersfield Fire Department, Hazardous Materials Division 2130 G St. Bakersfield, CA 93301. If you need any further information regarding this legal notice, please call me at 326-3979. Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey CITY of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON May 27, 1992 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Principal Longfellow School 1900 Stockton St. Bakersfield, CA 93305 Dear Sir: A Risk Ma:nagement and Prevention Program (RMPP) has been prepared by the Pepsi-Cola Bottling Co. located at 215 East 21st St., Bakersfield, CA. The.RMPP I - describes programs and controls designed to prevent a hazardous material accident. This RMPP will lee available for public review for the next 45 days at the Bakersfield Fire Department, Hazardous Materials Division 2130 G St. Bakersfield, CA 93301. If you need any further information regarding this legal notice, please call me at 326-3979. Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Hue~) CITY of BAKERSFIELD FIRE DEPARTMENT . u2101 H STREET S. D. JOHNSON " May,27,1992 . ~ BAKERSFIELD, 93301 FlEE CHIEF 326-3911 Principal Owens School ' 815 Potomac Ave. Bakersfield,· CA 93307 Dear Sir: A Risk Management and Prevention Program (RMPP) has been prepared by the Pepsi-Cola Bottling Co. located at 215 East 21st St., Bakersfield, CA. The RMPP describes programs and controls designed to prevent a hazardous material accident. This RMPP will be available for public review for the next 45 days at the Bakersfield Fire Department, Hazardous Materials Division 2130 G St. Bakersfield, 'CA 93301. If you need any further information regarding this legal notice, please call me at 326-3979. Sincerely, ° Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey "WE CARE" FiRE OEPARTMENT -- 2101 H STREET S. D. JOHNSON May 27,1992 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Principal Rafer Johnson School 1001 10th St. Bakersfield, CA 93304 Dear Sir: A Risk Management and Prevention Program (RMPP) has been prepared by the Pepsi-Cola Bottling Co. located at 215 East 21st St., Bakersfield, CA. The RMPP describes programs and controls designed.to prevent a hazardous material accident. This RMPP will be available for public review for the next 45 days at the Bakersfield Fire Department, Hazardous Materials Division 2130 G St. Bakersfield, CA 93301. If you need any further information regarding this legal notice, please call me at 326-3979. Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey CITY of BAKERSFIELD '.'WE CARE". FIRE OEPARTMENT 2101 H STREET S. D. JOHNSON May 27,1992 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Principal McKinley School 601 4th St. Bakersfield, CA 93305 Dear Sir: A Risk Management and Prevention Program (RMPP) has been prepared by the Pepsi-Cola Bottling Co. located at 215 East 21st St., .Bakersfield, CA. The.RMPP describes programs and controls designed to prevent a hazardous material accident. This RMPP will be available for public review for the next 45 days at the Bakersfield Fire Department, Hazardous Materials Division 2130 G St. Bakersfield, CA 93301. If you need any further information regarding this legal notice, Please call me at 326-3979, Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON .May 27,1992 BAKERSFIELD,' 93301 FIRE CHIEF 326-3911 Principal Williams School 1201 Williams St. Bakersfield, CA 93305 Dear Sir: ~ A Risk-Management and Prevention Program (RMPP) has been prepared by the Pepsi-bola Bottling Co. located at 215 East 21st St., Bakbrsfield, CA. The RMPP describes programs and controls designed to prevent a hazardous material accident. This .RMPP will be available for public review for the next 45 days at the Bakersfield Fire Department, Hazardous .Materials Division 2130 G St.,Bakersfield, CA 93301. If you need any further information regarding this legal notice, please'call me at 326-3979. Sincerely, Barbara Brenner ~ Hazardous Materials Planning Technician cc: Ralph Huey CITY of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON May 27,1992 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 The Bakersfield Californian Legal Notice Division P.O. Bin 440 Bakersfield, CA 93302 Dear Sir: Please publish the following public notice one time only. A Risk Management and Prevention Program (RMPP) has been prepared by the Pepsi-Cola Bottling Co. located at 215 East 21st St., Bakersfield, CA. The RMPP describes programs and controls designed to prevent a hazardous material accident. This RMPP will be available for public review for the next 45 days at the Bakersfield Fire Department, Hazardous Materials Division 2130 G St. Bakersfield, CA 93301. Contact Barbara Brenner for information regarding this RMPP. The bill for this service should be sent to the City of Bakersfield Fire Department, Hazardous Materials Division 2130 G St., Bakersfield, CA 93301. Please fax me a copy of this notice for proof review and note the date on which it will appear in the paper. Our fax number is 395-1349. If you need any further information regarding this legal notice, please call me at 326-3979. Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey City of Bakersfield Fire Depart t 2101 "H" Street Bakersfield, CA 93301 Fax Phone No. (805) 395-1349 Office (805) 326-3941 Date: PLEASE ROUTE AS SOON AS POSSIBLE TO: Name: 'L__e ~A-~. '-0:,.) ~ ~-,~ Company/Organization: ~,~V~c%.~¢~ ~'*~-;~r~',c,.,-,. Fax No. Sending Message to: ~ofl ~ - -g$'-Jo FROM: Name: ~-~~r~.~c~cxj ~ro ~~ Contact Person: ~z~-~,~rA ~~ Number of Pages(including cover sheet): Description of Materials Sent: ~,.>~o'~:c~ -' "' Special Instructions:" CITY of BAKERSFIELD "WE CARE" FiRE DEPARTMENT 2101 H STREET S. D.JOHNSON ""May27,1992 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Kevin Phillips Pepsi Cola Bottling Co. 215 E. 21st Street Bakersfield, CA 93305 Bakersfield Fire finds the risk management and prevention plan (RMPP) prepared by WZI Inc. regarding the use of anhydrous ammonia and sulfuric acid at the Pepsi plant, 215 E. 21st St., to be complete in scope and content. This risk management and prevention plan must be fully implemented by May 27, 1993. Bakersfield Fire Department will conduct follow up inspections to verify compliance with the risk management measures described in this plan. Doumentation must be retained that verifys that the material used to coat the sulfuric acid containment basin is resistant to corrosion from concentrated sulfuric acid. As we discussed, Pepsi may submit a revised RMPP implementation schedule in order to distribute the work more evenly, over the next year. However, the structUral evaluation regarding the adequacy of bracing of the ammonia system vessels must be completed according to the proposed schedule and meet the following requirements. 1. The' structural evaluation of the bracing of the ammonia vessels must be completed and stamped by a structural engineer registered in the State of ' California. 2. The structural evaluation and any plans for improvements shall be completed and submitted by August 31, 1992..The findings of this review, including engineering calculations, shall be submitted to the City of Bakersfield Building Department for review and approval. Pepsi will notify Bakersfield Fire Hazardous Materials DivisiOn at the time this information is submitted to the Building Department. 3. Documentation that the building, on which the evaporative condensers are located, met the earthquake and loading standards for this use as prescribed by the Uniform Building Code in effect the year in which the structure was built will be considered adequate with respect to the support of the evaporative condensers. Include information detailing the method used to secure the evaporative condensers to the structure. 4. The adequacy of the support for all other ammonia vessels (other than the evaporative condensers) must be evaluated based upon the requirements of the 1991 Uniform Building Code. · Review. of the safety of the Pepsi facility .via the process of risk management .planning has revealed two other areas of concern which require corrective action under the' Uniform Fire and Building Codes. The improvement of emergency' exiting from the production plant will be completed to achieve compliance with the Correction Notice issued by the Bakersfield Building Department on April 21, 1992. Installation of an ammonia diffusion system will be required by the Bakersfield Fire Department as described in the enclosed Notice of Violation and Schedule for Compliance. Notice of completion of this RMPP will be published in the Bakersfield Californian. Pepsi's RMPP will then be subject to a 45 day review period during which Bakersfield Fire will consider all public comments regarding the adequacy of this RMPP. Please call me if I can provide any further assistance or clarification regarding the risk management plan or code compliance requirements. Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey Larry Toler Mike Quon David Butt MEMOR.ANDUM "WE CARE" May 19, 1992 TO: Mike Quon, Bakersfield Building Department FROM: Barbara Brenner; Bakersfield Fire Hazardous Materials Division sUBJECT: Pepsi Cola Bottling Co., 215 E 21st St.. . Following our meeting with Pepsi on 5-15-91, I met with John Hodes of the Fire Safety Control Division to discuss the requirements for the type of hardware necessary for the ' new exit doors at Pepsi. Per 1991 UBC Section }t304(c) it appears that "no knowledge hardWare'' will be required. It is our understanding that the new exit door installations will be required to meet all of the provisions of the 1991 UBC. Based on our observation of existing 'exiting routes at the Pepsi plant, there are several 1991 UBC requirements which Pepsi may not be aware of and m~y overlook in the current planning'. Please be sure that the plans for the new exits specifically address the following UBC Sections. 3304(a) (b) - Doors are located within an accessible route of travel and that the exit doors swing in the direction of travel. 3313 - Exit illumination. 3314 - Exit signs and sign illumination. We appreciate the Building Department's action toward requiring the .upgrade of exiting for this hazardous (H7) Occupancy. · Through the risk management and prevention planning process, the Fire Departmen~ ha~ identified concerns regarding the adequacy of bracing of the ammonia vessels at the Pepsi plant. Because there is no record of inspection at the time of installation and several of the vessels do not have foundations supporting them, we have required that a structural analysis of the ammonia vessel support systems be incorporated into the risk management plan. We will need the assistance of the Building Department for review of the analysis and approval of any improvements. I discussed this situation with Eric Poore before writing the attached requirements. Please review these requirements and let. me know if there are any additions which need to be made in order to insure that this structural analysis will provide the information the Building Department will need to determine the adequacy of ammonia vessel bracing. .~ cc: Ralph Huey Larry Toler ~ "WE CARE" May 18, 1992 TO: Ralph Huey, Hazardous Materials Coordinator FROM: Barbara Brenner, Hazardous Materials Planning Technician SUBJECT: Pepsi RMPP Findings Having reviewed the hazard, risk and consequence analyses completed as a basis for the risk management and prevention plan for the use of sulfuric acid and anhydrous ammonia at the Pepsi Cola plant located at 215 E. 21st St., we find that the following issues require the implementation of risk mitigation measures in excess of those originally proposed by Pepsi. 1. In order to assure that a sulfuric acid spill will be contained within the secondary containment basin, an acid resistant coating material must be applied to the concrete basin. This finding is based on information found on page 13 of Effects of Substances on Concrete and guide to Protective Treatments, published by the Portland Cement Association in 1989. The coating of the sulfuric acid containment basin is provided for on page 52 of Pepsi's RMPP and specifications for the acid resistivity of the coating material have been stated in the letter to Pepsi finding the RMPP complete. 2. The emergency exit system needs to be improved to protect employees in the event of an anhydrous ammonia release. The anhydrous ammonia receivers, surge vessels and compressors are located inside the production plant area where employees work at various stations along the filling and palletizing lines. Presently one emergency exit serves the entire mixing, filling and palletizing area. These areas are interconnected so that they are all part of the hazardous occupancy. The worst credible case ammonia release is predicted to be from the ammonia surge vessel located inside the plant. The consequences of such a release are'rated as high. Pepsi Hazards Analysis, pg 27. The Bakersfield Building' Department has issued a Notice of Correction dated 4- 21-92 requiring the improveme.n.t of exits to meet the Standards for a H occupancy. The Pepsi proposal reviewed in our meeting with the Building Department on 5-15-92 appears to satisfy these exiting requirements. J 3. An ammonia diffusion system should be installed @er Article 63 of the Uniform Fire Code. The requirement for an ammonia diffusion system was not met when the Pepsi plant was built in 1974 under the 1972 UFC. There is .nO record of proper permitting of this refrigeration system installation. A school is located immediately adjacent to the plant and is within the area which could be subjected to ammonia concentrations far exceeding the IDLH. Pepsi Hazards Analysis, Appendix IV. A Notice of Violation and Schedule for compliance will be issued to Pepsi along with the completion notice for the RMPP requiring installation of an ammonia diffusion ;system within the one year RMPP implementation period. 4. Pepsi management need to meet With the administrators of the adjacent Community School and inform them of the hazards associated with the use of anhydrous ammonia at the Pepsi plant and the procedures for. emergency notification. Following this'notification by Pepsi personnel, Bakersfield Fire staff ' . will meet with the school administration and provide shelter in place instructions. 5. A structural analysis is' necessary t~o verify that the vessels in the ammonia 'refrigeration system are adequately braced. - Per the permit file records, the Pepsi ammonia refrigeration system was neither inspected nor finaled by City building officials at the time of installation in 1.974. VVZl Inc., the RMPP preparer, cannot attest to the adequacy of the vessel bracing ~ and acknowledges that several of these ammonia vessels are not supported by foundations. The potential consequences to human health is high .in the event of an ammonia release. Pepsi Hazards Analysis, pg. 27. . 'Tl~e RMPP proposes completionr of a structural evaluation on page 52. The specific requirements for this evaluation are stated in the notice of RMPP~ completion. 01."1~/9 0~:20 ~ ~O5 5:~8 I.~E: RACEHORSE 18ELD P.~I KRAZAN & ASSOCIATES, IN.C WELD TEST REPORT DATE .... ~.,~_.1 992 PROJ. NO, _~_2.~.~ 71 _ CO£1E ~....A.¥;~6 P1,1 ....................... FILLER~A'II~AIAL _ -,,~,~7~_!8 .................... PROCESS ...... ~ ............ 01AMET~ OF ¢II.LEA MA~ERIAt_I /8° MATERIAL SPECIFICATION. . .~ ....... POSITION OF TEST _.3G & ~ JOINT TIIICKNESS/DIAMET~R ~.. ~375". .~ WELDPROGRESS~ON _.. 3G..~)~__ ~ JOINT DgS~GN~- ~;,A · ~. 5 ,.~.~ A ........ CU~R~NT .~z'e.~ ...... POLA~ITY ..~6e__~ BACKING ~RIP ..... 1/~J~. ..... SHIELDING OAS ~/A _ ~LOW RATE ..... ~/~. RESULTS O~ TES1 $: GUIDED-BEND TESTS TENSILE STRENGTH, P.SI. ~OOt rACE ~ ...... FZ~_ .......... ~,..3c-~9_Q_~0r~a ..... i ....3~-con~.___ ~ ...... N../.A .... ~. 4G-Cos. forr~s 2 4qr'Oo~form$ THE ABOVE WCLDFRIS XX IS NOT ....... QUAIIF)FOFOR GROOVE . XX AND FILleT . XX WELDS ........ A~.,~ ......... POSIT~ON$ IN A(:C(~ROANC~VVIII'I .. ~ D1 ..1 ....... ~I(/~N' & A~SOCIATES M~i,3 OIf,~8: ~ro3no~levls * 3380 N. Win*~ * fteenO, Ca!~totr#a 9372~ , (20~) 2~t.7337 -- 4800 Easton Drive, Suite 114 Bakersfield, California 93309 Post Office Box 9217 Bakersfield, California 93389 805-326-1112 805-326-0191 FAX 83 East Shaw Avenue, Suite 250 WZl INC. Fresno, California 93710 209-222-1667 209-222-2630 FAX April 27, 1992 Ms. Barbara Brenner Hazardous Materials Planning Technician Bakersfield City Fire Department Hazardous Materials Division 2130 G Street Bakersfield, California 93301 Re: PEPSI-COLA Bottling Company Hazards Analysis Dear Barbara: Pursuant to your letter of January 24, 1992 requesting clarification on the PEPSI-COLA Bottling Company (PEPSI) Hazards Analysis, we offer the following: 'v//11. Question I - Section 2.2 of the text has been revised to answer this question. 0 t~,~lj01~, I~. Question 2- Each Study Form of Appendix III has been revised to answer this question. 3. Question 3 - Section 6.2.2 of the text and Section 11.2 of the Risk Management and Prevention Program (RMPP) have been revised to answer this question. Enclosed are revised pages of the text'"and Al~pendi~( '111 for your 'Razards A~alysis book. Please insert the reVised pages in the appropriate sections of your book and destroy the .:..~-,i'. ~' '"' "' .... """' : ;":": Yours very truly, Senior Engineering Advisor DB/jb Enclosures cc: K. Phillips - PEPSI 1619.0010.026 ...... 4800 Easton Drive, Suite 114 Bakersfield, California 93309 Post Office Box 9217 Bakersfield, California 93389 805-326-1112 805-326-0191 FAX 83 East Shaw Avenue, Suite 250 WZl INC. Fresno, California 93710 209-222-1667 209-222-2630 FAX April 27, 1992 Ms. Barbara Brenner Hazardous Materials Planning Technician Bakersfield City Fire Department Hazardous Materials Division 2130 G Street Bakersfield, California 93301 Re: PEPSI-COLA Bottling Company Risk Management and Prevention Program Dear Barbara: Pursuant to your letter of January 24, 1992 requesting clarification on the PEPSI-COLA Bottling Company (PEPSI) Risk Management and Prevention Program (RMPP), we offer the following: ''~'~'"'~7/ ~. Question I - Section 1.2.3 of the text has been revised and Table 1 has been added to answer this question. We have also revised section 3.1.4 of the Hazards Analysis. ~. Question 2 - Section 2.3 of the text has been revised to answer this question. 3c,,-"*Question 3 - Sections 3.1.3 and 4.0 of the text have been revised to answer this question. ~'"/Question 4 - Sections 1.2.1, 1.4 and 7.7 of the text have been revised to answer this question. t..5¢/ Question 5 - Section 5.1:1 of the text has been revised to answer this question. estion 6 - Section 7.7 of the text has been revised to answer this question. uestion 7 Section 7.7 of the text has been revised to answer this question. ~ Question 8 - Sections 8.0 and 11.3 of the text have been revised and Appendix E has been added to answer this question. 9. Q~estion 9 - No action required. .l~Question 10 - Section 4.1.2 of the Hazards Analysis has been revised to answer this question. .l~Question 11 - NDE means, Non-Destructive Examination. Frequency of this type of testing is not specified. Appendix ^, page 8 has been revised. ~2,~ Question 12 - This question has been added to section 11.2 Implementation Schedule. .~/- Question 13 - Section 8.1 of the text has been revised to answer this question. .~~Question 14 - Section 1.2.1 of the text has been revised to answer this question. We have also revised section 3.1.2 of the Hazards Analysis. Q uestion 15 - Section 8.1 of the text and Exhibit 14 have been revised to answer this question. J Question 16 - Section 3.1 of the text has been revised to answer this question. Sulfuric Acid ~/ Question I - Pursuant to your letter of March 25, 1992 this question has been answered. .2.(~/'Question 2 - Section 4.2.1 of the text has been revised to this answer question. We have also revised section 4.2.5 of the Hazards Analysis. ~ Question 3 - This question has been added to section 11.2 Implementation Schedule. 4. Question 4 - The correct vapor pressure of sulfuric acid is 68 degrees F. The text of the RMPP and Hazards Analysis have been corrected. When the Sulfuric Acid Delivery and Transfer Procedure is completed, it will become part of PEPSI's Maintenance and Procedure Program for Waste Water Treatment System manual. Page 2 Enclosed are revised pages of the text, new Table, revised Exhibit 14, revised Appendix A page and new Appendix E for your RMPP book. Please insert the revised and new pages in the appropriate sections of your book and destroy the old pages. If you have any questions, please call me. Yours very truly, David Butt Senior Engineering Advisor DS/jb Enclosures cc: K. Phillips - PEPSI 1619.0010.024 Page 3 · ~.~.. ~ ........ .. ... . '... .... . -..: -. ."' ''" _ April 9,..1992 ' ": {~PR-1 3' 199~: ' Barbara Brenner. .... City Of Bakersfield Fire Department ' .I 2101H Street ...... ' ' ' Bakersfield, CA 93301 .. ,~ ....... . .......... S. ubject~,:~ResP°nse-to'your Memo, dated 3/25/92._..~.~ Although' We ·'don't ,have rec°rds..on hand obtained necessary permits and inspections for the c0nstruction-,o'f ' our production, building' erected in 1'974. .'Our process. ~quipment,_ in¢ludi'ng the ammonia refrigeration.system for our.bottling lIn~., was installed, later the same ·year but did not' require permits or " inspection from city agencies. After a discUssion wi.th city'building officials last'week; it 'is our. understanding that. permits were not required for the 'installation of process equipment,· apparently since they are.'not .components of the' building itself.' '- .If'further. clarification :is'needed, pi'ease call. me as soon as possible..· We will-be qontac'ting Dave Butt of W.Z.I. to complete the response~ t'o your questions· raised and attempt to-submit the I- revisions needed by'4/27'/92. Sincerely yours.,' ' .... ~. ...KP~dh -'cc' Bob ¢°leman .. Dave Butt ' .... Bill Bentley Steve Alman DOT\BLDGPerm. iot .. . · ..-'. . 2: : 215 East.21st Street, Bakersfield, California 93305 · 805/327'-9991 · WATTS 1.-800-821-2936 CITY of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET S. g. JOHNSON March 25,1992 BAKERSFIELD, 93301 FIRE CHIEF 326-3911 Kevin Phillips Pepsi Cola Bottling Co. 215 E. 21 st Street .. Bakersfield, CA 93305 Kevin: Bakersfield Fire's response to your questions regarding my letter of 1-24-92 has been delayed pending inspection of the Pepsi facility by the Building Department. Because of these delays, I am extending the due for submittal, of Pepsi's revised Risk Management and Prevention plan to April 27, 1992. As a result of our meeting and the subsequent inspection of the plant, I have made the following amendments to my letter of 1-24-92. I will list the changes in a format similar to the letter referenced. All of the questions not specifically addressed below remain unchanged and should be addressed in either the revised RMPP or in a letter from the qualified RMPP preparer. .HAZARD ANALYSIS:~ 3. ,,"/-If it is. Pepsi's intent to coat the sulfuric acid containment basin with an acid resistant material, list this as a mitigation measure on the RMPP implementation schedule. No further explanation or data will be required as a part of the RMPP. The product specifications for the coating material should be retained as evidence of RMPP implementation. ANHYDROUS AMMONIA: ~ Reference to canister respirators should be removed from the RMPP and it should be made clear that SCBA are used as respiratory protective equipment. Two . SCBA must be available per the Uniform Fire Code to allow rescue back up via the buddy system. A plan to establish communication with the adjacent school regarding the hazards at the Pepsi facility and the method of notification of the school in an emergency must be included in the RMPP. ~. It will not be possibli~ to complete the emergenCy exiting plan until it is clear where additional exits will be added. At this time, Pepsi should add the completion of the exiting plan t° the RMPP implementation schedule following the determination of adequacy of eXisting exits. ~. This item needs to be' rephrased. What year 'was the ammonia refrigeration system installed in the production facility? Provide any records of building permits or inspections that Pepsi may have regarding this installation. The due date for supplying the answer to this ·question will be 4-8-92. SULFURIC ACID: "" 1. Delete this item. It has been addressed in the.haz-op document. .. As we discussed, many of the questions in my letter of 1-24-92 can be resolved · simply by rewording, adding some explanation detail or working out the inconsistencies in the RMPP text. Several of the items, such as #12, 13 and 14, can be-addressed in a letter from the qualified preparer to confirm that these issues have been considered and stating the findings. These type of items may not require any modification to the RMPP unless WZI or Pepsi recommends a change of practice. Any recommended changes in practice or additional planning may be added to the RMPP implementation schedule for completion in the future. The response to item 16 must be submitted by 4-8-92. Bakersfield Fire will then make a determination regarding the adequacy of exits from the facility. The only other Fire Code compliance item which I anticipate addressing as a part of the RMPP process is the addition of an ammonia diffusion system. We will notify you of our findings and requirements on these Fire Code compliance items following receipt of the · permit/inspection information for the refrigeration system. The revised.RMPP Will be due on 4-27-92. Please contact me if you have any questions or if I can be of other assistance. Sincerelyl Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey David Butt MEMORANDUM "WE CARE" 'March 13, 1992 TO: Valerie Pendergrass " FROM: Barbara Brenner· ~SUBJECT: Pepsi Cola Bottling .. -'- · ' A total of 42.5 hours have been spent to date ceviewing Pepsi'·s hazard, risk and consequence analyses and RMPP. 42.5 hours x 45 $ per hour = 1912.50 $. Please enter this amount into the computer so that a bill will be generated for the first quarter of 1992. Note the date that the entry is made on this memo and file it in Pepsi's RMPP file when you are done. cc:. Ralph Huey .. m mm m mm mm , mm RHPP ProJect History Date ·Event Description April 29. 1991 ~ZI .Proposal Accepted "~' Sept 10, 1991 Barbara Brenner issue's'~hcern~ ~O'NZI'~on Hazards * Support documentation needed (6 issues) * Further clarification needed (6 questions) Nov 12,'1991 NZI responds to Barbara Brenners's Concerns Nov 22, 1991 Barbara issues comments on integration o~ NZI's 11/21/91 response into Hazards an=~.s and states "a couple'o~ questions remain" ~ concerns listed Nov 27,' 1991 ~ZI submits RMPP document, to'..IBa~e~sfield Fire Nov 9, 1991. ~ZI submits response' to.Ba~b'a'ra's 11/22/91 questions and revised Hazards.~nal'ysis gan 24, 1992 Barbara'issues ttems.-"Of concern or which need * Hazard-Analysis ~ issues * RMPP, Ammonia 1_~6 issues. Sulfuric-Acid 4 issues Total H~ti~ate. Proposal Q/2~/~l 13.2~5 ~ i5.150 Over Budget 5,161 3,306 215 East 21st Street, Bakersfield, California 93305 · 805/327-9991 .' WATTS 1-800-821-2936 CITY of BAKERSFIELD FIRE DEPARTMENT 2101 H STREET , S. D. JOHNSON January 24, 1992 BAKERSFIELD. 93301 FIRE CHIEF 326-3911 Mr. David Butt Senior Engineering Advisor WZI Inc. P.O. Box 9217 Bakersfield, CA 93389 David: I have reviewed the revised'Hazards Analysis and the RMPP submitted for the Pepsi Bottling Plant. I have listed items of concern or which need clarification below. Two.days ago, I was using the Hazardous Materials Information Exchange Bulletin Board (HMIX) and found a memo to all users of ARCHIE 1.0 regarding a program error. I.have'attached a printout of .the memo for your review. You may wish to revise the modeling done for Pepsi's consequence analysis per the corrected version of ARCHIE. HAZARDS ANALYSIS: 1 You have evaluated the consequences associated with sulfuric acid overflow, hose rupture, fire exposure, etc. and have determined that offsite consequences are minimal. On page 3, it would be preferable to state that the hazards of sulfuric acid have been evaluated and that it has been determined that the offsite consequences are negligible instead of stating that an offsite consequence analysis was not required. This change would be consistent with Section 4.2.3, Page 19. / 2./Page 27 of the Risk Analysis defines the consequences of an ammonia release as potentially high. I agree that this is . appropriate~ however the haz-op work sheets are not consistent with this determination. The work sheets all list the line break scenarios as medium severity. ~. The...attached information from the Portland Cement Association indicates that concrete can be expected to rapidly disintegrate ~hen exposed to a 10% sulfuric acid solution. This information disputes the conclusion of page 28 that the concrete containment basin will hold 93% sulfuric acid for up to 30 days. RMPP: ANHYDROUS .AMMONIA ~. The potential for explosion of anhydrous, ammonia is an .important hazardous property of this material'. Information regarding potential for explosiOn should be included in Section 1.2.3. It is particularly important that employees involved 'in emergency response activities understand this possibility. (See film referenced in item 11 below) ~/~/' .~/~ What method will be used by employees to determine i,f the · ~ ~oncentration of ammonia is within the range handled by canister respirators? (Section.2.3 c, pg 10) '~// How does the proposed maintenance schedule compare with the manufacturers specifications? Are the manufacturer's equipment manuals and specifications available? (Section 3.1.3, pg 28 & Section 4.1) . Is there a standard procedure for the addition of ammonia to the system? /. Proper design is frequently referenced as a key element minimizing the possibility of an ammonia release. Is the system design documented by process and instrument diagrams and are these' kept current ? What is the procedure for approving modifications to the ammonia system-? (Section ~/ Why does turning'off the ammonia system during periods while the plant is unattended reduce' the risk (probability and j consequences), of a release to neighbors? (Section 7.7, pg.42) 'Risk reduction is accomplished by reducing incident .probability and the consequences. Maintenance practices and operator training reduce the probability of an' ammonia · release. How will the consequences of. an ammonia release be reduced? (Section 7.7, pg 42) will the hazards of ammonia be communicated to the inistrators of the adjacent school? How will the school ~ staff be notified during an emergency? ,~. Emergency action plans and fire prevention pl~,ns must comply with CAL 'OSHA .standards. ( CA Code of Regulations, Title 8, . . Sections 3220 and '.3221) Specifically, will procedures be established to train employees who are to perform critical .-operations prior to ~vaCuation ? '' Recent research, at an ammonia .training facil'ity in sWeden, indicates thatthe addition of water to liquid ammonia evolves greater quantities of the gas than if the liquid is left alone until it can'be pumped into a containment vessel. The video 'tape reference for this information, "Valuable Lessons Learned. Regarding Anhydrous Ammonia", is available at the Fire Library located at-the City/County'Fire training, facility on Victor' St. TaPes may be borrowed using a Kern Co. Library card. It is still considered appropriate to.use water spray to absorb ammonia gas. (Section 8.4, page 44) ~ What does the "major inspection and. servicing program" "conducted and documented every two.years by the'refrigeration expert and Pepsi mechanics", referred to on page .10 of the hazard analysis, consist of? (Section 9.1, Pg 46) What is the appropriate ~frequency for NPE inspection as Aequired by Appendix. A pg. 8? '~ re vessels adequately braced to prevent falling Or'toppling //~/~uring/ an earthquake? ' ~ Is verbal notification of a fire or chemical emergency ~ adequate or is an audible alarm system necessary for' the evacuation of such a large area? Evaluate the requirements of Cal OSHA, CA Code of Regulations Title 8, Section 6184.- Is the 150 pound ammonia cylinder safe from physical damage on a daily basis and from falling\,debris or equipment during an earthquake? ~/.Emergency evacuation routes through obstructed pathways and through sliding fire doors are unacceptable. The metal grated door behind the compressors does not qualify as an exit. I have attached the exit plan and marked the areas which need change. Are two approved exits required under CAL OSHA, Title 8, Section 3250? /~/What year was each system (the bottle and can lines) originally installed? Please add this information to the equipment report. SULFURIC ACID ~. How often will the sulfuric acid system audit take Place? . (Section 9.2, Pg 46)~Zxd~/~ ~n~-D~ - . ' . 2 he hazard analysis notes that the sulfuric acid tank will not be filled unless the containment basin is free of water. How is the containment basin drained?~ Is there a 'lock on any· valves controlling drain lines and a procedure to check the position of the valve prior to filling the tank? The haz-op work sheets note various ~r ural controls in effect during delivery of sulfuric acid. The likelihood of a sulfuric acid release during delivery is rated as low. Is there a· written procedure used ~o train the staff which documents their responsibilities regarding the delivery of .~iulfuric acid? s the vapor, pressure of"sulfuric acid quoted at 68 F or C? variations occur within these documents. (Section 7.7 RMPP and pg. 3 of hazard, analysis) These questions need to be addressed before Bakersfield Fire will find this RMPP complete. 'In order to'avoid unneceSsary work, it is advisable that we agree that the items of concern have been adequately resolved before changes'are made in the RMPP. The items which involve additional planning·, i.e # 8, may either be addressed by adding to the RMPP or scheduling additional planning as a part of the RMPP implementation schedule. The revised RMPP will be due on March 24, 1992. I am available to discuss any of the items noted above with you. Please call if I can be of assistance. Sincerely, Barbara Brenner Hazardous Materials Planning Technician '\ I ~ cc: Ralph Huey , \ \ 4800 Easton Drive, Suite 114 ~_.~_ . '~. Bakersfield, California 93309 ' Post Office Box 9217 Bakersfield, California 93389 805-326-1112 805-326-0191 FAX 83 East Shaw Avenue, Suite 250 WZl iNC. Fresno, California 93710 2~9-222-1667 209-222-2630 FAX December 9, 1991 Ms. Barbara Brenner Hazardous Materials Planning Technician Bakersfield City Fire Department Hazardous Materials Division 2130 G Street Bakersfield, California 93301 Re: PEPSI-COLA Bottling Company Hazards Analysis Dear Barbara: Pursuant to your letter of November 22, 1991 requesting additional information on the PEPSI-COLA Bottling Company (PEPSi) Hazards Analysis, we offer the following: The ammonia piping of both refrigeration systems has been installed to allow for movement should an earthquake occur. The pipes lay on top of channel iron supports or lay in pipe raceways which allow free movement. The piping system is constructed of schedule 80 material and extra heavy fittings which provide additional strength. The magnitude of the worst credible earthquake on the White Wolf fault is estimated to be 7.8 on the Richter Scale. The above text shall be added to section 6.1.1 of the revised Hazards Analysis. A release of 500 pounds of ammonia from the can line ammonia surge vessel and related system is defined as the "worst credible" release in section 5.1.1, A. of the revised Hazards Analysis. The second ammonia refrigeration system handles the Bottle Line Processing System. It holds approximately 400 pounds of ammonia. For emergency planning purposes, it is expected a break of a 1 inch high pressure inlet line to the Bottle Line ammonia surge vessel, would provide the worst credible release for this system. The above text shall be added to section 5.1.1, A. of the revised Hazards Analysis. 2. The metal building referenced in paragraph 2.i., of WZl's letter of November .12, 1991 is the manufacturing and warehouse building located to the north of the sulfuric acid area. The building has three (3) two hour firewalls with fusible link firedoors. The fusible link firedoors would automatically close if a fire should occur, which would retard the spreading of a fire. The building located to the west of the sulfuric acid area which consists of the shop, fleet, supply and loading canopy are the areas which are sprinklered. Exhibit 3 has been revised to show the firewalls and sprinklered areas. The text of section 4.1.2 of the revised Hazards Analysis shall be clarified on the above. 3. We have reviewed the possibility of the sulfuric acid in the storage tank reaching a temperature of 572 degrees Fahrenheit, if the vending building next to the sulfuric acid storage tank should catch on fire. Based on our research it would take a minimum of 15 hours for the surface of the tank to reach 572 degrees Fahrenheit if the heat source was continuous. We assume the response time of the Bakersfield City Fire Department would be less than one hour, which means the heat source would begin to reduce and the sulfuric acid tank could not achieve the 572 degrees Fahrenheit required to generate sulfur trioxide fumes. The method we Used'to determine the heat transfer is shown in Exhibit 1. The method is very conservative, because we did not consider the fact that fire pulls in cooler air which would reduce the heat transfer to the tank and we did not consider the amount of heat required to increase the temperature of the sulfuric acid in the tank. 4. When you complete your research on the effects of sulfuric acid on concrete we will address this question. Enclosed is a copy of the revised Hazards Analysis for PEPSI. Please destroy the original Hazards Analysis we submitted or mark it "OBSOLETE", if you retain it for your records. If you have any questions, please call me. Yours very truly, David Butt Senior Engineering Advisor 'l DB/jb Enclosure cc: K. Phillips - PEPSI 1619.0010.021 Page 2 EXHIBIT 1 PROBLEM: Determine the amount of time required for the surface of a tank to reach 572 °F, when the tank is located 9 feet from a burning building emitting 1800 °F. ·SOLUTION: Estimate amount of time the .first molecule in the tank will reach 572 °F, using one dimensional heat Conduction. SCHEMATIC: ~ TIME FOR THIS MOLECULE TO REACH 572° F /'"~'- HEAT CONDUCTED THROUGH THE 9'-0" AIR SPACE ~ 9'-0" --~-'· 1. Estimate temperature change as a function of time. where: T molecule = temperature of first molecule (°F) Ti = initial molecule temperature (°F) Th = high temperature of building (°F) x = distance of air (ft.) o< = diffusivity of'air (ft.2/day) T = time required' ·(day) Page I working parameters: r' ~ .I T molecule = ' 572 °F Ti = 60 °F ..': Th · = 1800 °F x . = 9 feet T molecule = 'Ti + ( Th- Ti ) ( erfc x ) 2. Solve .for diffusivity of air where: k = Thermal Conductivity (Btu/ft. °F day) (from Figure B.72) m = Heat Capacity (Btu/Ibm. °F) (from Figure B.62) p = Density (Ibm/ft.'~) Conductivity Volumetric Heat Capadty oC= k rn.p Page 2 Range of Values: k = 1.09 to 0.34, depending on temperature 1.09 @ 1800 °F 0.60 @ 572 °F 0.34 @ 60 °F m = 0.25 to 0.28, depending on temperature 0.29 @ 60 °F 0.28 @ 1800 °F p = _+. 0.07513 Ibm/ff.3 OC.max = '1.09 Btu/ft. ° F day 0.25 Btu/Ibm o F x 0.07513 Ibm/fi? max = 58.03 .~2/day oc min = '0.34 Btu/ft. °F day .0.28 Btu/Ibm o F x 0.07513 Ibm/fl.3 oc min = 16.16 ft?/day Page 3 3. Solve for T, when T molecule is 572 °F. i. Evaluate erfc T molecule = Ti + ( Th - Ti ) ( eric x ) 2~C< T 572 °F = 60 °F + ( 1800 ° F- 60°F ) ( erfc 9 ft. ) '2~T (~572°F-60°F) =(erfc 4.5 ft. ) ( 1800 °F- 60 °F) V/ oc T 512 °F = (eric 4.5 ft. ) 1740 °F ~ oc T 0.29 = ( erfc 4.5 ft. ) ~/c<r from Table 4.2, erfc of 0.29 is 0.74 Page 4 ii. Estimated time at maximum diffusivity 4.5 ft. - 0.74 = ~.:, ~/~ T · 4.5 ft. 0.74 = V/ 58.03 T 0.74(~/58.03 ) (~/ T ) =4.5 4.5 ( 0.74 ) ( ~/58.03 ) 0.74 x 7.62 4.5 0.80 T = 0.64 day .or 15.36 hours Page 5 iii. Estimated time at minimum diffusivity 0.74 4.5 ft. , 4.5 ft. 0.74 = · 0.74(~/16.16 )(~/ T ) =4,5 ~/T = ( 0.74 ) ( ~/16.16 ) 4.5 0.74 x-4.02 4.5 2.97 ~/ T = 1.52 T = 1.522 T = 2.31 days Page 6 REFERENCES: Heat Transfer Formula Kreith, F., 1976, Principles of Heat Transfer, Third Edition. Figure B.62 and ·Figure B.72 ~. Prats, .M., 1982, Thermal Recovery, Monograph Volume 7, p '223 and 228 Table 4.2 Burger, J., '1985, Thermal Methods of Oil Recovery, p 157 DB/jb/rc 1619.0010.022 Page 7 ~.~ . . . -. . ~ 0.8 ..... .2-3 ~ / ~ O.S ' - - ·2.0 0.4 ...... . I.~ . · " .'~. FI~.' B.72-- Thormal ~nductivities of ~ases at ~ arm? 3'5 / ~ · ! · 3, 3 '. ! i , I' ./ : ; · 1,1 ~ / t 3.3 '~ '1,0 ~ : 1,2 ~ , ~ / ~ O.9 ~ : .: I. ' · " ~;.~.~~ o. s ' / o.~ / , .. . .~.,~ . / / .o.,: // , . . ,. o.~ ,/ ., ~ ' . ~1,! .1 . ' . . " '; . ' ~ ; 0.~ [ ' . .... .~ c~o~ ~x,o~t.' c ~ '~' '; : i '. '" ' ' .OxYGeN,. I 0.3 '" ' , T~'~r~, .g. l~ool~ooleOo Fig. " ~.~2Heat ca '~oo~°' :..:.',;'...' . . . ~ .. ... . :'- ' ,p. ~o Pactty. of gases at ' · ' 5-'::7 . ::.,:.... , ~tUllh~ TASL£ 4.2' "'Talk of . . c~p(x~)¢dcx c~p(x~)crfc x x icdc x c~p (xz) c~C x . + ~- I x e~c X cxp(x~)c~c x 2x .02 ;977~ .97783 .~39 .05 .137S6 .41430 · ~ .~2 . ' .9~76 .~3 .20 .~969 .37854 .73259 .10 .~87M ' · ,89~ .~29 1.25 .07710 ,36782 .77U~0 · '~:'?'~ .14 .~5 .85974 ' ..01771 ..35 .05624 ' ..34796 .87127' ;:~ .16 .~ '.~228' .02282 .~ .~772 .33874 .91847 . · ]8 .~ .82538 '.02849 .45 .~31 .32996 .9661 I .22 .75570 .793.18 .~142 .55 .02838 .31359 .~258 ~4 .~ .77T~ .~865 ,~' .02365 .30595 '.! 1136 .26 .91310 .76297 ,0~35 .65 .01962 .29865 .1~8 · ~ .69212 .74857 .~51 .TO .01621 .291~ .2~1 · ~ .67137 .73~ ,07311 1.75 .0i333 .28497 1.259~ · ~ .57161 .67079 .12214 2.~ .~68 .25~ 1.51215 .42 ,55253 .65912 ,13~ .05 .~375 .2~'16, .56334 · ~ .53378 "~779 ,i~28 .10 .~298 ' .24512 .61472 · ~ .515~ .63679.' .15584 . .15 .~236 .2~27 .~628 · ~ .49725 . .62~ .. '.16771 .20 ,~i86 .23559 .71803. · ~ .~' .59574' '~20~7 .35 ,~89 .22255 .87424 ~8 .41~ .5~687 .23133 .45 ,~53 .21459 ' 1.97912 · ~ .3961'4 .56280 .24483 Z~ ,~! .2 {081 2.03175 .62 .38059 .55898 ~5858 .~ .~24 .20361 .137~. . · M .36MI .5~39 .27256 .70 .~13 .19687 .243~ .70 ,322~ .52593 .315~ 3.~' .~2 .i 7~ 2.5~ 14 .' .74 .~532 .51~ .~ .20 ' < I'0's .16873 .77954 .~ ~57~ .48910 .39180 ' 3.~ < I0-s .15529 3. l~2 ,~ ~2M86' .47~ .423~ .70 ' < I0- s .14743 .322~ · ~ ~ .4~53 .47207 4.~ < I'O-s .]37~ 3.65052 .92. .19323 .4~7 .48858 .i0 < I0-s .13383. .7~19 . x cxp(xZ)crfcx csp'(x=)crfcx + ~- I cxp(x=)cdcx cxp(x~.)crfc x +.~- I 4.50 · 12248 4.20019 7.00. .07980 6.97845 .60 .I 1994 .31'048 .20 .07762 '/.20195 · 70 .I 1749 .42087 .40 .07'556 .42557 .80 '.[15[4 ,53136 .60' .07361 .64929 .90 .1128&' ,64194 .80 .07175 7.87311 5.00 .11070 4.75260 8.O0 .06999 8.09702 .20 .10659 4,97417 ' .20 .06830 .32101 · 40. .10277' 5.'19602 . .40 ..06670 .54508 .60 .09921 .41814 . .60 .06517. .76923 .80 .09589 .64049 .80 .06371 8.99344 '6.00 ' .09278 5.86305 9~00 ,0623 I' 9.21772 .20 .08986 6.08581 .20 .06097 .44206' .40 .0~712 .30874 .40 ' .05969 '.66645 ;60 .08453 .53184 .60 .05846 9.89090 .~0 · '.08210 . .75508 .80 05727 I0.11539 lO.IX) .05614 10.33993 December 16, 1991 Mr. David Butt Senior Engineering Advisor WZI Inc. P.O. Box 9217 Bakersfield, CA 93389 David: I have reviewed the revised Hazards Analysis and the RMPP submitted for the Pepsi Bottling Plant. I have listed items of concern or which need clarification below. HAZARDS ANALYSIS: 1. You have ~ne--~consequence~arralys~s~~_~_rdin~ sulfuric acid overflow, hose rupture, fire exposure, etc. and have determined that offsite consequences are minimal. On page 3, it would be preferable, to state that the hazards of sulfuric acid have been evaluated and that it has been determined that the offsite consequences are negligible instead of stating that an offsite consequence analysis was not required. This change would be consistent with Section 4.2.3, Page 19. 2. Page 27 of the Risk Analysis defines the consequences of an ammonia release as potentially high. I agree that this is appropriate, however the haz-op work sheets are not consistent with this determination. The work sheets all list the line break scenarios as medium severity. 3. The attached information from the Portland Cement Association indicates that concrete can be expected to rapidly disintegrate when exposed to a 10% sulfuric acid solution. This information~disputes the conclusion o~.page 28 that the concrete containment basin will hold 93% sulfuric acid for up to 30 days. _Th_~ cond~of the c~inment~in ref_~ect's the action~,ef-this_~id on c0n~g~te~ Wh~e~small a~nt~s of acid ha~v~escaped~around fittings, the c~crete is,~oticeably corr~d~ed. 4'. The release scenario referred to on page 21 is the worst credible case rather than the worst case. Please 'resolve these . inconsistencies and submit the appropriate page revisions. RMPP: 1. The potential for explosion of anhydrous ammonia is an important hazardous property of this material. Information regarding .potential for explosion should be included in Section 1.2.3. It is particularly important that employees involved in' e~rgency response activities understand this possibility. (See film referenced in ftem xx below) 2. What method will be Used by employees to determine if the concentration bf ammonia is within the range handled by canister respiratOrs~(Section 2.3 c, pg 10) /. How does the proposed maintenance 'schedule compare with the manufacturers specifications? Are the manufacturer's specifications available? (Section 3.1.3, pg 28) 4. Is there a standard procedure for the addition of ammonia to the system? 5. Proper design is frequen{ly referenced as a key element minimizing the possibility of an ammonia release. Is the system design documented by process and instrument diagrams and are these kept current ? What is the procedure for approving modifications to the ammonia system ? (Section 5.1.1) 6. Written operating procedures do not ~nsure that mechanics are well trained. Written procedures provide materials to supplement training and provide a standard reference for safe operations. ( Section 7.1, pg 40) · Are manufacturer's equipment manuals maintained and available for the refrigeration equipment? 8. Why does turning off the ammonia system durin~ Deriods while the plant is unattended reduce the risk~n~ease to neighbors? A~e parts of the system ~o]ateH so that thc wors~ · ~r~dibl~ ~eQ~ase wo,,]d ho ~e~uced? (Section 7.7, pg.42). 9. Maintenance ..practices and operator training reduce the probability of an ammonia release. Risk reduction is a combination of the reduction of incident probability with lessening of consequences. (Section 7.7, pg 42) ' Wi~ an emergency respons~'planbe established and exercise~?~ : ~ Emergency shut down procedures and 'responsibilities ~'a~nn% · particularly important because the hazard analysis identified improper shutdown during an emergency as a hazard. How will the hazards of ammonia be communicated to the ~' administrators of the adjacent school? How will the school staff be notified during an emergency?Q%.q~ %~ %~the vapor pressure of sulfuric acid to be quoted at 68 F or C? Variations occur within these documents. ~ . Emergency action plans must comply with OSHA standards. (29 CFR Secti0n 1910.38) 11. Recent research at an ammonia training facility in.Sweden indicates that the addition of water to liquid ammonia evolves greater quantities of the gas than if the liquid is left alone until it can be pumped into a containment vessel. The video taped reference for this information, "Valuable Lessons Learned Regarding Anhydrous Ammonia", is available at the Fire Library located at the City/County Fire training facility on Victor St. Tapes may be borrowed using a Kern Co.~Library card. (Section 8.4, page 44) 12. What does the "major inspection and servicing program" "conducted and documented every two years by the refrigeration expert and Pepsi mechanics", referred to on page 10 of the hazard analysis, consist of? (Section 9.1, pg 46) How often.will the sulfuric acid system audit take place? (Section 9.2, Pg 46) 14. Are ~ssels a~equately braced to prevent falling or toppling - ~ during an earthquake? 15. Is verbal notification of a fire or chemical emergency adequate or is an audible alarm system necessary for the evacuation of such a large area? 16. Emergency evacuation routes through obstructed pathways and through sliding fire doors are unacceptable. The metal grated door behind the compressors does .not qualify as an exit. I have attached the exit plan and marked the areas which, need change. 17. 'Is the 150 pound ammonia cylinder safe from physical damage on a daily basis and from falling debris or equipment during an earthquake? 18. The hazard analysis notes that the sulfuric acid tank will not be filled unless the containment basin is free of water. How is the containment basin drained? Is there a lock on the valve controlling the drain line and a procedure to che~k the position of the valve prior to filling the tank? ~ · 19. The haz-op work sheets note various procedural controls in effect during delivery of sulfuric acid. The likelihood of a sulfuric acid release during delivery is rated as low. Is there a written procedure used to train the staff which documents their responsibilities regarding the delivery of ammonia? 4800 Easton Drive, Suite 114 - ~ Bakersfield, California 93309 Post Office Box 9217 Bakersfield, California 93389 805-326-1112 ... 805-326-0191 FAX 83 East Shaw Avenue, Suite 250 WZl INC. Fresno, California 93710 209-222-1667 209-222-2630 FAX November 27, 1991 Ms. Barbara Brenner Hazardous Materials Planning Technician Bakersfield City Fire Department Hazardous Materials Division 2130 G Street Bakersfield, California 93301 Re: PEPSI-COLA Bottling Company Risk Management and Prevention Program Dear Barbara: WZl Inc. on behalf of PEPSI-COLA Bottling Company (PEPSI) is pleased to submit the enclosed Risk Management and Prevention Program for PEPSI's Bakersfield facility. If you have any questions or require additional information, please call me. Very truly yours, David Butt Senior Engineering Advisor DB/jb Enclosures cc: K. Phillips - PEPSI 1619.0010.020 Cih/ oi~kersfield TRANSMITTAL SLIP Date...../.~.~...~..~..~/.. ......................... For Your:-- [] Signature ~ Action [] Information I-1 File Please:-- [] Return [] See Me I-1 Follow Up [] Prepare Answer Copy to: ................................................................................................... Memo: .... ~.~.._.~...~....,.'.~........~....~......6'~.~.~Z2...~ .................................................. ........... 4800 Easton Drive, Suite 114 Bakersfield, California 93309 Post Office Box 9217 Bakersfield, California 93389 805-326-1112 805-326-0191 FAX 83 East Shaw Avenue, Suite 250 WZl iNC. Fresno, California 93710 209-222-2630 FAX November 12, 1991 Ms. Barbara Brenner Hazardous Materials Planning Technician City of Bakersfield Fire Department Hazardous Materials Division 2101 H Street Bakersfield, California 93301 Re: PEPSI. COLA Bottling Company -Hazards Analysis Dear Barbara: Pursuant to your letter of September 10, 1991 requesting additional supporting documentation and information/clarification on the PEPSI-COLA Bottling Company (PEPSI) Hazards Analysis, we offer the following: suPPORT DOCUMENTATION NEEDED 1. A major earthquake would not be expected to rupture both ammonia refrigeration systems because the property is not located on a fault and the nearest significant active fault is about 37 miles south of the PEPSI facility. 'The part of the PEPSI facility which houses the ammonia systems was built according to Uniform 'Building Code in 1974. As a result, facility damage due to ground shaking is anticipated to be minimal. A geologic map of the Bakersfield area which indicates there is no faulting on the property is included as Exhibit 1. The property is located on Pleistocene alluvial deposits comprised of sand, silts, and clays. The Kern County Seismic Hazard . Atlas which is utilized in emergency preparedness planning does not identify any faults underlying the PEPSI facility. The PEPSI facility is not located within an Alquist-Priolo Special Studies Zone. The Safety and Seismic Element of the Kern County General Plan (Saint-Armand, Engel, Park, and Williams, 1974) reported the entire central Kern County area is subject to moderate to severe ground shaking. All earthquakes have components of both vertical and horizontal ground acceleration (ground shaking). The ground shaking effect as distance increases from faults is attenuated. The most severe ground shaking would be caused by an earthquake on the White Wolf Fault, which is identified on Exhibit 1. This was determined by reviewing the history of earthquakes in California from records catalogued by the California Division of Mines and Geology (Real, Toppozada and Parke, 1978) since 1900, and more recent updates. From these records and mathematically computing the peak horizontal ground accelerations (Campbell, 1981) at the PEPSI site from various active faults in Southern California, it was determined that ground shaking at the ~ . PEPSI site from the la-rgest.~m'ax~imum-credible-earthqu~k-~-~the:White-Wolf-Fa_u~,--~,~-~,z would be more-severe than the-~-a-~e~t--r~a~imum credible earthquak~e-~-n-a-ny ~.~.~ other active fault in California. Peak horizontal ground accelerations from that .~ ~m% ~ event would be 0.35 g. The largest maximum probable event has ~,:C~~L hypothetical horizontal ground accelerations of 0.225 g. The above text shall be added to section 6.1.1 of the revised Hazards Analysis. References Saint-Armand, P., Engel, R., Park, W. H., and Williams, B. F., 1974, Geology and Earthquake Hazards Planning Guide to the Seismic Safety Elements to Kern County, California: Kern County Council of Governments. Real, C. R., Toppozada, T. R., and Parke, D. L., 1978, Earthquake Catalog of California, January 1, 1900-December 31, 1974, First Edition, California Division of Mines and Geology Special Publication 52, 15 pp. Campbell, K. W., 1981, Near-Source Attenuation of Peak Horizontal Acceleration, Bulletin of the Seismological Society of America, Vol. 71, No. 6, pp 2039- 2072. 2. The sulfuric acid used by PEPSI is purchased from Pressure Vessel Service, Inc. (PVSI). 'PVSI is the local representative of General Chemical Corporation, who manufactures the sulfuric acid. The sulfuric acid used by PEPSI is defined as "non-fuming". A Material Safety Data Sheet (MSDS) on the sulfuric used by PEPSI is included as Exhibit 2. Also a MSDS shall be added to the revised Hazards Analysis as Appendix I. 3. The PEPSI ammonia refrigeration systems at the Bakersfield facility, are supervised and operated by highly trained and experienced personnel. The PEPSI personnel are supported by an ammonia refrigeration expert who is readily available on an as needed basis. The ammonia refrigeration systems are well maintained and a major inspection and servicing program is conducted and documented every two years by the refrigeration expert and PEPSI mechanics. These regular major inspections and servicing programs in conjunction with the daily maintenance and inspection programs conducted by PEPSI's highly trained and experienced mechanics minimize the risk of equipment failure and repairs and provide the basis of reliable data. Page 2 The PEPSI risk analysis conducted on the ammonia refrigeration systems has rated the probability of equipment failure as generally Iow, based on the minimum repairs of the compressor systems as documented by the major inspection and servicing program. The PEPSI ammonia refrigeration systems are highly automated. The design of the Bottle Line Processing System and Can Line Processing System is such that the trained operator needs only to switch on either Processing System and the ammonia compressors for that Process System will automatically begin operation. The highly trained, experienced mechanics inspect the ammonia compressor twice daily. The combination of highly automated systems and highly trained, experienced mechanics reduce the probability of human errors. The above text shall be added to section 4.1.2 of the revised Hazards Analysis.. 4. Sulfuric acid does present environmental consequences and section 3.2.4 of the revised Hazards Analysis shall be corrected. 5. The definitions of Iow, medium and high probability will be the same as listed in section 6.1.2 of the current Hazards Analysis. The definitions of Iow, medium and high probability shall be added to section 6.2.2 of the revised Hazards Analysis. 6. A new Exhibit 7, which defines the size of the sulfuric acid containment area and the distance between the containment area and the adjacent vending building, shall be added to section 3.2.2 of the revised Hazards Analysis. A copy is enclosed for your review. FURTHER CLARIFICATION NEEDED 1. The PEPSI hazardous material business plan shows the correct distance to the Community School. Section 5.1.2 of the revised Hazards Analysis shall be corrected. 2. The likelihood of a fire in the PEPSI facility has been rated Iow for the following reasons: a. The manufacturing building has been defined as a no smoking area. b. Smoking is allowed only in approved areas. c. On-site fire extinguishers are located at strategic points in the facility. d. Personnel training in the proper handling and operation of equipment will reduce the possibility of a condition which might create a fire condition. Page 3 e. Routine inspection and maintenance of equipment will reduce the possibility of a condition which might create a fire condition. f. Flammable or combustible materials are stored in only approved areas. g. Trash or waste materials which might contribute as a ignition source are not allowed to "stack up" and are removed from the facility. h. The administrative offices are equipped with heat sensing devices and alarm pull stations which are monitored by ADT Security Systems. ADT would notify the City of Bakersfield Fire Department if a device was actuated. i. The metal building is constructed with~_fir, e_-.~7~v-~ll~and fire doors which would retard the spreading of a fire. ~'~ ~i('¢, t?,c~ ,, j. The s_upp__ly-___and-shep_~;areas are equipped with water 'sprinklers which are actuated by heat fuses.-.~~ ~.~ ~;.%c~3~.~ ~ 5~r;c $-~ k. Personnel training in fire prevention methods minimize the possibility of a fire. The above text shall be added to section 4.1.2 of the revised Hazards Analysis. 3. The likelihood of a sulfuric acid release from a bulk tanker truck during the filling of the sulfuric acid storage tank, has been rated as a Iow probability. The worst case scenario would be a hose coming loose from the pump transferring sulfuric acid from the bulk tanker truck to the storage tank. The bulk tanker truck has a Iow pressure shutdown switch installed on the transfer pump discharge. If a drop in pump pressure occurred the pump would' immediately stop. Only one or two gallons of sulfuric acid would be spilled. The bulk tanker truck carries soda ash, which would be immediately applied to the sulfuric acid. The soda ash would neutralize the sulfuric acid and then be diluted with plenty of water. During transfer of the sulfuric acid, the bulk tanker truck parks adjacent to the sulfuric acid storage tank which is 105 feet from Grove Street. The sulfuric acid would be spilled on PEPSI's property and would be neutralized and diluted before any sulfuric acid would travel off-site into public areas or enter sewer or storm drains. There would be no damage to public or private property due to a sulfuric acid spill on PEPSI's property. The above text shall be added to section 4.2.1 of the revised Hazards Analysis. 4. The sulfuric acid storage tanks are manufactured by Poly Cai Plastics. I requested information on exposure of the tank to fire. The reply from Poly Cai Plastics is included as Exhibit 3. Page 4 Their field experience indicates that tanks built of high density, crosslink polyethylene plastic material will soften and deform rather than split or rupture when exposed to fire. Should flaming debris fall on top of the tank, they have seen the tank burn down to the liquid level and extinguish itself. Sulfuric acid is not a flammable liquid as noted on the MSDS, Exhibit 2. During a fire the worst consequences would be damage to the tank, allowing some sulfuric acid to leak into the containment area. There would be no off-site release of sulfuric acid. vJ~c~ o~o-V c~cc~n ~ ~o~.~r ,b-~o~(;~ (~ .lpg? The sulfuric acid h~ard and operabili~ study forms in Appendix VI of the revised H~ards Analysis shall be revised to include a fire. ~ ~oot~ ~ 5. The sulfuric acid used by PEPSI is .manufa~ured by General Chemical Corporation. ~hibit 4 is a leEer from General Chemical stating, they believe poured concrete retaining walls should last in excess of 30 days when continuously exposed to 93 percent sulfuric acid. ~'~ r.%~ ;~ Should a problem occur at the PEPSI facili~ and sulfuric acid was exposed to the concrete retaining walls, the m~imum exposure time would be three to four days. The above information shall be added to se~ion 6.2.2 of t~e revised H~ards Analysis. 6. The carbo aoaler room has a separate ventilation system than the produ~ion area. The carbo cooler room ventilation system is designed to exhaust the air in 5 minutes. The produ~ion area has five evaporative coolers located on the roof which blow fresh air into the building. The five evaporative coolers would displace the air volume of the produ~ive area in 5 minutes. Experiments conduced by the Unde~riters Laboratories showed that ammonia has an ignition temperature in air of 1,~0 degrees fahrenheit. Ammonia has a ve~ narrow flammable range in air of only 16 to 25 percent by volume. Due to this Iow susceptibili~ to ignition, ammonia is classified by the U. S. Depa~ment of Transpo~atian as a nonflammable gas. See U. S. Oode of Federal Regulations, 49 OFR 173.300(b)(1). The produ~s of combustion of ammonia are neither toxic nor h~ardous since they are nitrogen and water. The release of ammonia in the carbo cooler room would most likely result from a break in a liquid ammonia line going to or coming from the surge vessels in one of the ammonia refrigeration systems. The line break would most likely result from an ea~hquake. If a line did break in the carbo cooler room the consequences to a worker would be high. ,The likelihood of a line breaking would be minimal ~cause the building was built in 1974 to withstand ea~hquakes as required by the 1972 bui~aing standards. ~ ~ ~ ~. ~~ Page 5 The carbo' cooler room employees receive safety training and proper evacuation procedures which would minimize the danger of injury due to an ammonia line break. After you have reviewed this letter and advised the information submitted answer your questions, I will revise the PEPSI Hazard Analysis. If you require additional information, please call me. Very truly yours, David Butt c.c. K. Phillips - PEPS1 DB/jb Attachments 1619.0010.001 Page 6 ,.~ .'~- s','.,,._J~ , . .....:.- -~ '~" -~ ~ SITE LOCATION '.. ~.-~:" 2 ~ F": .n.. i.._~' ] ~ ''/ .= C r'.~,'~.= . ~ - ._.~" ~-~.',~,~ i . .~ ~= ~- ~ .~ ~ '~: ~' ~' ~. ~ .r . ~ ..... .' :.d'-~. '"" " ' '~' "~' '~ "~ '" :'x" ~ -'4,; :~- 'r ': ~ ,~i :L .'1 :' ff~ = . ~ /.i' '.~ =~t .~..,.= ? ... .. .,- -,_.. ~ -.--. ~. : "~ ' -:~ .- ~ .=.~. .' R~_': ;-'T-.'~t'"" ' · r.'~ 2 ~Z' ~;' ::'"::': ~' o*;L' ..': -.':.u. ?,..., ....... -.--' "~': ..... ~' = : · ~em %.. :": ~-.'o24 - "' ' : ' ' :,, ;,-.'.~ .:. ~ .. ',: :~ 9¢¢~',.,...t .~ .;:''/ ~, . . .,. : '.' ' ..~:,.~:.:....~:;~:':'"',' -'L -. [~_~.~ ~ ,.:... ~..x ; · ... WHITE WOL~ i ' ;:: - ~..'"~ -:~ FAULT ..., - ~--~q' -"~ ?'- '~"¢'r-~ .... =':~:~u':'~ '~ ..~ ~'"r · t '~[~'~' '>~.:','~.=~L. ~ .t .-~- T':;'~'~-~-- ~ .... I . ~ -~ .... ' } ~,~, .~,'-u.~L~ !', I :.J.' .... L'~.T~'~. ~ ,' ' I ~. J' j ~-r~'~''~'~ [.... t. =.....~-_ .':~ ~=:~ ~ ~ - , f~, ~.~' , ', - '. ,' :' : ~:, - -. t... =., :,J .x ~.'~.'];'.'.~' .~/ . .': '_%J ~,*. BAKERSFIELD, CALIFORNIA PEPSI~OLA BO~LING COMPANY Statute Miles GEOLOGIC MAP 0 5 ~0 DATE I IEXHIBIT 11~1 I 1619,~10A 1-A I EXPLANATION te~ace depustt~ Pli~Pleist~n~ nonm~ne Middle ~d/or lower PH~n~ nonm~e Middle and/or lower Plic~na j ~ ~ ~ gnei~, ~¢s = sehht ~anitie roe~ ~ *,,:~ m.,.~ ~ 'BAKERSFIELD, CALIFORNIA "'-"~:~ ~ PEPSI-CO~ BO~LING COMPANY GE~OGIC MAP LEGEND Chem ¢oi PRODUCT SAFETY DATA SHEET SULFURIC ACID TRADE NAME (COMMON NAME) [] C.A.S. NO. [] GENERAL PRODUCT CODE ~ SULFURIC ACID 7664-93-9 CHEMICAL NAME AND/OR SYNONYM SULFURIC ACID Synonym: battery acid FORMULA MOLECULAR WEIGHT H2 SO 4 (Various Concentrations) in water 98.08 ADDRESS (No.. STREET. CITY. STATE AND ZIP CODE) GENERAL CHEMICAL CORPORATION 90 EasVHalsey Road Parsippany, N.J. 07054 CONTACT PHONE NUMBER .~ LAST I,.~,.~JE DATE CURRENT ISSUE DATE Manager of Product Safety (201 ) 515-1840 } July, 1989 ' May, 1990 I EMERGENCY PHONE NUMBER .- (800) 631-8050 SKIN OR EYES:'lmmediately flush with plenty of water continuing for at least 15 minutes. ' Remove contaminated clothing while washing. Continue flushing with water if medical attention is not immediately available. INGESTION: Do not induce vomiting. If conscious, give several glasses of milk (preferred) or water. INHALATION: Remove to fresh air. Observe for possible delayed reaction: If breathing has stopped, give artificial respiration. If breathing with difficulty, give oxygen, provided a qualified operator is available. GET.IMMEDIATE MEDICAL ASSISTANCE for ingestion, inhalation, eye contact, irritation~ or burns.. -'-~ i.:j~l~ti~:~f'fb'~'0r/~id mist can cause irritation or'corrosive burns io'the upper respiratory ~ystem: inCtuding'~0~,~,' ' ' " ~'~;i ' ~- m~uth: a~d throat. Lung irritation and pulmonary edema can also occur. LC 5o (mist, animals): 20-60.mg/cu.m. - Ref. (a). · ~- "C~ cauS~ irritation and corrosive burns to mouth, throat, and stomach. Can be fatal if Swallowed." .._i'.~.. L-i- . - . -. i..... ;-.... · - SKIN Can cause severe burns. EYES Liquid contact can cause irritation, corneal burns, and conjunctivitis. Blindness may result, or severe or permanent injury. Mist contact'may irritate or burn. Reference (b) .... PERMISSIBLE CONCENTRATION: AIR BIOLOGICAL --~ iSLE SECTION J) 1 mg/m3 (as H ~SO ,~) (OSHA) TLV: same (ACGIH) IDLH 80 mg/m ~ None. UNUSUAL C~ON~C TOX,C,TY (1) Erosion of teeth, (2) lesions of the skin, (3) tracheo-bronchitis, (4) mouth inflammation, (5) conjunctivitis, (6) gastritis. -- Reference (a). NO- NOT DETERS,NED ~ N^- NOT ^PPLIOASLE "' EXHIBIT 2A :IRE AND EXPLOSION LASHPOINT ' O C AUTOIGNITtON O C FLAMMABLE LIMITS IN AIR (% BY VOL.) · Not flammable TEMPERATURE Not applicable LOWER - Not applicable UPPER - Not apPlicable 3 oP~ cup [] CLOSED cup JNUSUAL FIRE AND EXPLOSION HAZARDS Flare ,mable and potentially explosive hydrogen gas can be generated inside metal drums and storage tanks. Concentrated sulfuric acid can ignite combustible materials on contact. :IRE EXTINGUISHING AGENTS RECOUI~flDED If involved in a fire, use water spray; avoid spraying water into containers. If only a small amount of combustibles is present, smother fire with dry chemical. · .-'IRE EXTINGUISHING ,~GENTS TO AVOID :. Use water spray or other suitable agent for fires adjacent to non-leaking tanks or other containers of sulfuric acid. ~PECIAL FIRE FIGHTING PRECAUTIONS Do not use solid water streams near ruptured tanks or spills of sulfuric acid. Acid reacts violently with water and can spatter acid onto perrsonnel. VENTILATION Sufficient to reduce vapor and acid mists to permissible levels. Packaging and unloading areas and oPen processing equipment may require mechanical exhaust systems. Corrosion-proof construction recommended. Closed ventilation systems (e.g. vapor hoods) are frequently used in the electronics industry. NORMAL HANDLING Do not get in eyes, on skin, on clothing: Do not breathe vapor or mist. Use protective equipment outlined in Section E. Procedures are detailed in references listed in Section J. Do not add water to acid. When diluting, always add acid to water cautiously and with agitation. Use only with adequate ventilation. STORAG~ Protect from physical damage. Store in cool, well-ventilated area away from combustibles and reactive chemicals. Keep out of sun and away from heat. Keep containers upright. No smoking in storage area. SPILL OR LEAK (ALWAYS WEAR PERSONAL PROTECTIVE EQUIPMENT- SECTION E) · Dilute small· spills Or ieaks Cautiously with plenty of water. Neutralize residue with alkali such as soda ash or lime. Adequate ventilation is required for soda ash due to release of CO2 gas. (See Section I for disposal methods). No smoking in spill area. - Major spills *must be handled by a predetermined plan. Diking with soda ash is recommended. Consult References. Section J. - Attempt to keep out of seWer.` Any release to the environment of these products may be subject to Federal and/or· state.reporting'. i.; If stored in metal containers, vapors can contain explosive hydrogen gas.' '. . ...~=. ~ EYES AND FACE SEE PAGE 5. SEE PAGE 5. OTHER CLOTHING AND EQUIPMENT SEE PAGE 5. EXHIBIT 2B MATERIAL I~ (AT NORMAL CONDITIONS): APPEARANOE AND ODOR tx] LIQUID I-I SOLID [] GAS Oily, colorless to slightly yellow, clear to turbid liquid. Odorless. SPECIFIC GRAVITY VAPOR DEN~I~rY BOLLING POINT Approx. 310 o C ~" ~) (liquid)' (A~R- ~) For 94% 1.842 Not applicable MELTING POINT Approx. -27 o C ; SOLUBILITY IN WATER pH VAPOR PRESSURE Complete 1% solution: pH = 0.9 < 0.001 EVAPORATION RATE % VOLATILES aY VOLUME · (ButylAcetate-1) [] (Ethel-l) [] (At20"C) · Not applicable " Not applicable . ' STABILITY CONDITIONS TO AVOID Tem p6ratu r-es -Of:30'0d e-g: C .6?~l'iig fieF.' yields .sb If [] UNSTABLE [] STABLE . 'g~sT.~vh~ch is tox~c~6-r~-osiv-e, a~d ah oxidizer.~ INCOUPATIBILI3Y (M^'rERIALS 'to N~ro mm~u~s, ca.ides, dienes, almhols (when heated): cause explosions -- Refs. (g,h). Ox~izing agents, such as ch~rates and ~rmanganates: cause tires and ~ssibly explosions. Allyl mm~unds and aldehydes: undergo ~lymeriz~ion, ~ssibly violent -- Ref. (g), (~ntinued, $e~ion K). ~R~m ~mMPOSJT~N P~TS Suffur tr~x~e gas: see ~ve. Also this is a rite risk ~ in ~nta~ w~h o~an~ material. ~R~ ~LYMER~T~ ~DIT~NS TO AVOID ~ MAY OCCUR ffi WILL NOT OCCUR · NA % . .....:~: '~ "~.'~.: - " .' ' ~"7;' ' . ~"~ .: .,&~.: . ~'/:~:.~; :...., '~': "-:..~' ~i[~atoRmu~o~[m~ca.s.~' ' · .... ~...' - .~.~ . ~a~a~la .: ' : " NOT APPLICABLE .... - PROPRIETARY- TRADE SECRET 3 .......... . ..... '- EXHIBIT 2C DEGRADABILI3Y/AQUATIC TOXICITY OCTANOIJWATER PARTITION COEFFICIENT Aquatic Toxicity: ND 24.5 ppm/24 hr./bluegill/lethal/fresh water 42.5 ppm/48 hr./prawn/LCs0/salt water EPA HAZARDOUS SUBSTANCES 1000 J (CLEAN WATER ACT SEC. 311) [] [] IFSO REPORTABLE QUAN'rI~': # (100% H2 SO4 basis) 40CFR YES NO I 116-117 WASTE DISPOSAL METHODS (DISPOSER MUST COMPLY W TH FEDERAL, STATE AND LOCAL DISPOSAL OR DISCHARGE LAWS) Treatment or disposal of waste generated by use of this product should be reviewed in terms of applicable federal, state and local laws and regulations. Users are advised to consult with appropriate regulatory agencies before discarge, treatment or disposal. RCRA STATUS OF UNUSED MATERIAL IF DISCARDED HAZARDOUS WASTE NUMBER: (IF APPLICABLE) I 40 CFR ' EPA Hazardous Waste No. D0002 (corrosive) I PERMISSIBLE CONCENTRATION REFERENCES (1) OSHA Z-List; 29 CFR 1910.1000 (Revised 1989) (2) ACGIH 1989-90 List, "Threshold Limit Values for Chemical Substances...". Am. Conf. of Governmental Industrial Hygienists, Cincinnati 45202. REGULATORY STANDARDS I D.O.T. CLASSIFICATION: Corrosive material I 49 CFR 173 D.O.T. Hazardous Materials Table 49 CFR 172.101 DOT ID Number: UN 1830. GENERAL (a) Documentation of the Threshold Limit Values, 4th Edition', 1981 Am. Conf. of Governmental Hygienists, Cincinnati 45202. ' (b) NIOSH, Registry of Toxic Effects of Chemical Substances, 1982-83, Accession #WS 556 00 000, PB81-154478, Nat. Tech.-Info. Service, Springfield, VA 22161. (C) "Criteria for a. Recommended Standard...Occupational Exposure to Sulfuric Acid", NIOSH U.,S. Dept. of HHS, 1974, PB233098, Nat. Tech. Info. Service, Springfield, VA 22161. '. J. REFERENCES-- General (continued) - (d) NIOSH/O.SHA, -Pocl~et Guid~ t° ChemiCal Haza~'ds...", September, 1'g85. (e) ~N.!OSH/OSHA -~ Occupationa Health Guidelines for Chemical Hazards -- Sulfuric Acid", 1978. (f) Allied Chemic'al Technical Service Report for storage and handling procedures. (g) NFPA Manual 491 M, "Manual of Hazardous Chemical Reactions, 1987 Nat. Fire Protection Assoc., Boston 02210. (h) Bretherick, L., Handbook of Reactive Chemical Hazards, 3rd Ed., 1985 Butterworths, Boston. .- G~ REACTIVITY DATA - Incompatibility (continued) -..'- .. .... ~"i AlkaliS,' ~rnines, water, hydrated salts, carboxylic acid anhydrides, nitriles, olefinic organics, glycols, aqueous acids: caUse ;' strong exothermic reactions. -- Refs. (g h). Carbonates, cyanides su f des, sulfites, metals such as copper: yield toxic gases. - Refs, (h). Also for meta s, see hydrogen generat on, Section C. EXHIBIT 2D Sulfuric Acid Page 5 of 5 SECTION E PROTECTIVE EQUIPMENT 1. HEAVY HANDLING 2. SPECIALIZED HANDLING · (only applicable when using the closed ventilatioft system mentioned on p. 2): Respiratory Protection Respiratory Protection Where required, use a resPirator approved by NIOSH for sulfuric acid. If misting above 1 mg H2SO4/wear: Generally not required. For emergency, e.g. a misting (a) gas mask with acid gas canister and also with situation, use a respirator approved by NIOSH lot high-effiCiency particulate filter; (b) High-efficiency sulfuric acid. See this i~age, under '1. HEAVY particulate respirator; (c) other choices, Reference (d). HANDLING - Respiratory Protection'. . Eyes and Face Eyes and Fa=e ... As a minimum, wear hat, chemical safety goggles, As a minimum, safety glasses with nonpedorated and optionally full-face plastic shield. Do not wear sideshields. Add a face shield if pouring liquid. For contact lenses, leak or spill or other emergency, use chemical safety goggles and optionally, full face shield. Do not wear contact lenses. H~nds, Arms, and Body Hands, Arms, and Body As a minimum, wear acid-resistant* apron, protective As a minimum, wear acid-resistant apron and gloves.*. clothing, boots, .and gloves for routine product use. For leak or spill or other emergency, use full For increased protection, include acid-resistant protective clothing (see this page under '1. HEAVY trousers and jacket. HANDLING - Hands, Arms, and Body)". ' '* . Other; Clothing and EquiPment Eyewash and quick-drench shoWer faCijities. Neutralization supplies and equipment.. ;Preferably rubber. EXHIBIT 2E POLY CAL PLASTICS A Division ~f Abell Corpor~hon . . November 12, 1991 ... W. Z. I. 4800 Easton Drive Suite 114 Bakersfield, CA. 93309 Attn': Mr. David Butt Dear Mr. Butt. The photographs that I recently sent to you show the remains after the truck and trailer caught fire and burned to the ground. The plastic tanks next to the burned truck had fertilizer stored in them. It is obvious there was intense heat. The tanks were scorched, but there was no product loss. We 'do not have any data that gives us the fire characteristic-~ you have requested. We only have field experience. The tanks when. full of liquid seem· to fair .quite well when -. '. exposed to. fire..· We have, in one other·.· 'case, seen .the'..tank burn· · :' · · down. to ..the liquid, level~ but'.'extinguished itself when-it:reached"~ ' . :!-!'il-,.:: >'.'.'.. ?'i...theii:'Iiquid.':;,i.~.. L. Want !.[.,t0:.: add':: that::, the-~, tank':'.caUgh~[ fire,i: as). a~:.; reSul~ :~:~':;"::~.~.::.-:t ;~:~:[[~;.~.~" ;:[[:t~(~'d'~O's s 1-'~nk~[98 l'~hyi~fi~,~' Ct6 ~'s.['fn~+-po lY~thyI'e'ne';:~:;- in'~.m0-s ~: ca s es'?(:;[~:'.q'~:.;:~ [~{~%?t.~.`~;~....:~.~J[.{?J~[:~..~::~.:~:..~.`:t:~.:~t~I~;::~.~2`~' .:r--L::r ...... ;[?'.t:~:':-:' "'%1-5 ;:; ".:::'::"l:- -'"2::7:'~:'"-': ~''~/'~l~':['i3-'': '~",;'-': '-'f'~-":" ~'--'~ ~ .'"".'-~- ".*':,. :~? ?~.~ ':. ::~: :~.:-._: i n f o ~a t i o ~' .:-.'u ~ ~ f'~ ~ .....q.-. D o'-~. no ~'~ ae's i ~ ~'t'~ (:-. t 3.::: c a ~ ~::- i ~-: sou':. n a?? ':-"~(~"~ '.:'-' "-' ·~ ~-'-'-. :.':::"? ~'" .......... :' .. ' :'..' '.":' ':'. .... :. ': ". ' .... .. ' · · '- ':" ..... ':.~.-?"~'.~ :/':i. '..: :~:""~ '.."l ."' :~[~:;~i:.'."'"'.'' Jori Streete~'''''''' "'" ' ' '/' ': .... :' '- ' ' ~ ":: .... .' "" '" "" · .:./,:.' . .' General Sales ~anager · .' ..-' 2( JS/vig Enc: P:O. r~oY, 80 · 8055 $. ASH * FRENCH CAMP, CA 9523~, ' PHONe. STC_/G~KTON E:,",C, HANQE [209] 982-4904 TELEFAX NO [209] 982-0455 . EXHIBIT 3A Test Procedure ASIH D635-60, Tests for' Flarrrnabllt ty. of Self-Supporting Plastics . Underwriters' LaboratorieS, Bulletin ~94- · :': 'i:; ....'" 5 Autolgnltlon Temperature'i'UL Butlet~n:~l§ ' gurnlng, Arcing, .lgnttioh. and TraCking of Plastics ~sed In Electrical gppllhnces Flash Point' (Open Cup) ,:: AST~ 092 ~ ~tor Vehtcle Standard (HVS).~302 . ':'i:" '~:: :"": J · ' Yalue Obtained wttll'Ht~RtEX iiOPE Burning Rate = (Classified as 94 lib by:this Ha te r t al ~olyetJ~yl'ene ~rood, BI rch ~dood, Red Oak 430°F test),.' jgn'tt'ton Te~_perature, :. : 8tO . 7~0 '78t POLY CAL TANKS EXHIBIT 3 C 1619.0010A ." o_., .enecal. Syracuse, New York 13202 (315) 478-2323 ~ November 1, 1991 Mr. Dave Butt WZI, Inc. .. 4800 Easton Drive, Suite 114 Bakersfield, CA 93309 Dear Dave: In accordance with your request, we are commenting on the effect of 66° BA (93.19%) sulfuric acid on poured concrete retaining walls. We believe that a six-inch wall should last in excess of 30 days provided that: 1. the construction is rich in aggregate and lean in portland cement content, 2. acid concentration is maintained and not diluted with rain or other water sources, 3. there is to be no heating of the acid--including the heat of mixing with water, and 4. the acid will be quiescent, that is, no agitation of the acid in the vicinity of the wall. Certainly, a properly Constructed concrete wall will last well for normal emergency situations with minimal loss of wall whereby an accidental release is cleaned up within, say, three days. We'trust that'this is the information you desire. Please let us know if we may provide further assistance. AJI statements, and date given herein am believed te be accurate and mllabte but am pmaented without guaranty, our products am mede without representetion or warranty that any such use i~ free o~ patant infringement, and we or b%at other measures mey not he required. ExHiBIT 4 ~':' / \ '.*. 5'-6" ~" / \ ..'. VENDING ::~ I" I ;:-' BUILDING ' "' '; '~' " ""' '.*' ~SU F - L UR CAC D ~. :~ ~'_.:~'~; .'~._ ?" STORAGE TANK ' .'~.~..-. :~0:: ?.,'~ I------- 4'-7" ·" ~ .... ,,....;-....-._ :, ?:,'. ,-~., ,.:- · ot ,,.,.u. ,., ....:; -,. -.~.:y' -. ~...' ?...o. ,, :, I .'; --- -,-- 6" WALL THICKNESS "~ '". TYPICAL .;?..::: .-. :,..0, ..~,....-0 .- ,.., · BAKERSFIELD, CALIFORNIA PEPSI-COLA NOTES: BOTTLING COMPANY 1. CONTAINMENT WALL HEIGHT IS 1'-8". 2. CONTAINMENT AREA CAPACITY IS SULFURIC ACID 110 CUBIC FEET OR 822 GALLONS. CONTAINMENT AREA 3. SCALE IS 1/4"=1' DATE 11/91 I 1619.0010A IEXHIBtT 7 I I CITY of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET S. O. JOHNSON November 2 2 · 19 9 i B.~,KERSFIELD, 93301 FIRE CHIEF 326-3911 David Butt Senior Engineering Advisor o WZI Inc. P.O. Box 9217 Bakersfield· CA 93389 David: ° Thank 'you for the response to our questions regarding the Pepsi Hazards Analysis. Following are my comments regarding integration of. this information into the 'text of the existing Hazards Analysis. 'A couple of questions remain and these are noted with the section to which, they apply. 1. Definition of the worst credible case ammonia release: The information which yOu submitted regarding the seismic analysis for this site needs to include.the magnitude of the worst credible earthquake on the White Wolf fault. It should also include the reasons ~hy the plant piping is expected to tolerate a force of .35 g without failing. Inclusion of this information should satisfactorily substantiate the increased likelihood that one system will fail over the likelihood of a simultaneous failure of both .systems in the worst credible earthquake. Define the total release'of the ammonia from the 500 lb system as the "worst credibleY release. This release will be acceptable for purposes of the ammonia offsite consequence analysis. For emergency planning purposes, please include the diameter of'the hole through which a worst credible release of the 400 lb. ammonia.system would be expected to occur. 2. Probability of a fire at the Pepsi facility:' Section 2i - Is the metal building referred to the one adjacent to the sulfuric acid storage area? Include the time rating for the fire walls, i.e. 1 hr, 2 hr. Section 2j - Is thelbuilding directly adjaqent to the sulfuric acid storage area One .of the sprinklered areas? Please clarify these statements to address thes~ two questions. 3. Offsite consequences of sulfuric acid: Consider the generation'of sulfur trioxide during a fire in -in the plant adjacent to the sulfuric acid tanks. The Arson investigators' with the Bakersfield..Fire Safety Control Division indicate that normal structure fires burn at approximately 1800 F. Sulfur trioxide fumes escape.sulfuric acid at temperatures exceeding 572 F (300 C) per the MSDS. 4. I am researching the effects of sulfuric acid On concrete and have.requested a publication titled "Effects of Substances on Concrete and Protective Treatments" from the Portland Cement Association. Unless Pepsi can prove that their containment basin meets the specification outlined by General Chemical, concrete rich in aggregate and lean in cement, or my research indicates that. ordinary concrete can reasonably contain concentrated sulfuric acid, they will be required to coat the containment basin per the 1988 UFC. Aside from the 'specific changes noted, the information supplied in your response to.our questions should be integrated into the existing Hazard Analysis as you have proposed. There has been a Change in Bakersfield Fire's interpretation of a reportable release of which you need to be aware. A reportable release is now considered to be; any release of a hazardous material which threatens life, health or the environment or which equals or exceeds 42 gallons ( 1 barrel) of a liquid, 500 pounds of a solid or 200 cubic feet of a gas. This change has been made in order to insure compliance with the reporting quantities set for petroleum- products in above ground tanks prescribed'by Division 20, Chapter 6.67 of the CA Health and Safety Code. We are attempting to establish one value which complies with as many of the regulations as possible. However, any unauthorized release from an underground storage tank in the City must be reported to Bakersfield Fire under Chapter 6.7 of the California Health and Safety Code. I appreciate all of your efforts on this project. Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey FIRE DEPARTMENT 2101 H STREET S. D. JOHNSON --~- -.--~¢neem1~er 10, 1991 BAKERSFIELD, 93301 FIRE.CHIEF 326-3911 Mr. David Butt Senior Engineering Advisor WZI Inc. P.O. Box 9217 Bakersfield, CA .93389 David: Having reviewed the hazards, risk and consequence analyses submitted for the Pepsi-Cola Bottling Co., the following items remain issues of concern. I have broken, the items into two sections, those requiring supporting documentation and those which have either not been addressed yet or require clarification. Support Documentation Needed: 1. Provide specific information which documents the conclusions that a major earthquake would not be expected to cause a rupture in both ammonia systems.. This information should include the location and name of the fault which presents the greatest hazard to the Pepsi plant, the type and magnitude of ground accelerations which would be expected at the Pepsi site, pertinent geologic characteristics of this site, the year of the building code under which the building housing the ammonia refrigeration equipment was constructed, the type of damage which may be expected at the plant and reference citations for the sources Used to predict the impact of an earthquake on this specific site. 2. Please submit a manufacturer's material safety data sheet for the sulfuric acid 'to verify that this product is not fuming sulfuric acid. 3. Section 4, page 9 indicates that the probabilities of accidents were determined by use of reliability data° Please site the source of reliability statistics used to predict the probability of human errors and recovery rates as well as equipment failure and repair rates for the Pepsi risk analysis° 4. Please provide copies of the literature which'indicate that sulfuric acid does not have environmental consequences. See attached information from the Northridge Toxicology Center which disputes this conclusion. 5. Provide the definitions of low, medium and high probability as used in this study. 6. Provide the dimensions of the sulfuric acid containment basin and the distance between the containment basin and the adjacent building. Further Clarification Needed: 1. The vulnerability analysis indicates that the Community School is .1 mile (528') east of the Pepsi plant. Pepsi's site diagram, submitted with their haz mat business plan, shows a distance of 130' from the front of the wastewater facility to the rear of the mobile classroom facilities. Which information is accurate ? 2. Why has the likelihood of a fire in the Pepsi plant been rated low? Specify fire prevention controls. 3. The likelihood of a worst credible case sulfuric acid release, from a bulk tanker, has been rated as low. From our discussions, I understand that the rating of low is based upon the sulfuric acid distributor's prior experience. What are the consequences of such a release? How much sulfuric acid could be spilled, where would the acid flow, would the acid travel off Site into areas of public access, could public or private property damage· occur due to concentrated acid exposure, would, the acid be able to enter sewer or storm drain systems ? 4. The hazard analysis for the sulfuric acid facility does not include exposure of the tank and material to fire. What are the probability and consequences of a sulfuric acid release during a fire? Pepsi's hazardous materials management plan indicates that acetylene and LPG are' stored and used in the·vending building immediately adjacent to the acid storage tank. Oxygen and combustible liquids are shown to be stored and used in the fleet shop on the other side of the acid storage. 5. The predicted consequences of sulfuric acid releases as low appear to be based upon the ability of the concrete dike to contain the liquid. How long can the concrete be expected to withstand the corrosion by of the acid? 6. Section 4, page 12 notes that indoor releases of ammonia are dangerous due to the potentiaL for ammonia vapor buildup in areas of the building which are not well ventilated. What is the capacity of the plant ventilation system? Is the ventilation system capable of diluting ammonia vapors during an ammonia release so that explosive ranges are not reached? What are the severity of consequences to a worker in the carbo cooler room at the time of a an ammonia release? I need the responses to these questions and the additional information before I can review or comment on the adequacy of the RMPP. Please call me if any of my concerns are unclear as stated above. Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey "WE CARE" FIRE DEPARTMENT 210'1 H STREET D. S. NEEDHAM July 16, 1991 BAKERSFIELD. 93301' FIRE CHIEF 326-3911 Mr.'Robert E. Coleman Vice President Pepsi Cola Bottling Co. 215 E. 21st Street Bakersfield, CA 93305 Mr. Coleman: As of July 1~ 1991, the City of Bakersfield h&s instituted a fee of $45.00 per hour for the review of Risk Management and Prevention Programs. Time spent conducting site inspections, r.eviewing hazard, risk and consequence analyses and .meeting with company officials or consultants will also be billed at this rate. Upon 'completion of your Risk Management .and Prevention Program, you .will be billed for the time that Bakersfield Fire Department personnel have spent reviewing the project. If you have any questions regarding this policy, please call me at (805) 326- 3979. ~ Sincerely, Barbara Brenner Hazardous Materials Planning Technician cc: Ralph Huey 4800 Easton Drive, Suite 114 Bakersfield, California 93309 · Post Office Box 9217 Bakersfield, California 93389 805/326-1112 -- 805/326-0191 FAX May 6, 1991 Ms. Barbara Brenner Hazardous Materials Planning Technician City of Bakersfield Fire Department 2101 H Street Bakersfield, California 93301 Re: PEPSI Hazards Analysis and Risk Management and Prevention Program Dear Barbara: We will be reviewing two Acutely Hazardous Materials (AHM), Anhydrous Ammonia and Sulfuric Acid when we review the PEPSI Bakersfield facility. The last facility we reviewed which had two AHMs was North American Rotc Engravers in early 1989. The reporting format since 1989 has changed; therefore, we are submitting a proposed format for PEPSI's Hazards Analysis and Risk Management and Prevention Program. Please review the enclosed and advise if they are acceptable. Thanks for your assistance. Very truly yours, David Butt Senior Engineering Advisor DB/jb .. Enclosure 1619.0010A.002 PROPOSED HAZARDS ANALYSIS TABLE OF CONTENTS Section 1.0 Introduction 2.0 Summary 3.0 Hazards Identification 3.1 Anhydrous Ammonia 3.1.1 Chemical Identity of Acutely Hazardous Materials 3.1.2 Location of Acutely Hazardous Materials 3.1.3 Quantity 3.1.4 Nature of Hazard 3.2 Sulfuric Acid 3.2.1 Chemical Identity of Acutely Hazardous Materials 3.2.2 Location of Acutely Hazardous Materials 3.2.3 Quantity 3.2.4 Nature of Hazard 4.0 Hazard and Operability Study Results 4.1 Anhydrous Ammonia 4.1.1 Summary 4.1.2 Release Scenarios 4.1.3 Off-Site Consequences 4.1.4 On-Site Consequences 4.1.5 Human Error Analysis 4.2 Sulfuric Acid 4.2.1 Summary 4.2.2 Release Scenarios 4.2.3 Off-Site Consequences 4.2.4 On-Site Consequences 4.2.5 Human Error Analysis TABLE OF CONTENTS (Continued) Section 5.0 Vulnerability Analysis 5.1 Vulnerable Zone 5.2 Human Populations 5.3 Critical Facilities 6.0 Risk Analysis 6.1 Release Probability 6.2 Severity of Consequences DB/jb 1619.0010A.003 INC. PROPOSED RISK MANAGEMENT AND PREVENTION PROGRAM TABLE OF CONTENTS Section I. Purpose II. Introduction III. Certification IV. Revision Record 1.0 Background 1.1 General Business Information 1.2 Description of Acutely Hazardous Materials Used 1.3 General Ammonia Refrigeration Processes 1.4 Operation of the Ammonia System 1.5 Operation of the Sulfuric Acid System 2.0 Description of Acutely Hazardous Materials Accidents 2.1 Accidents at this Location 2.1 Underlying Causes 2.3 Measures Taken to Prevent Recurrence 2.4 Accident Investigation Procedures 2.5 Release Reporting Procedures 3.0 Equipment Report 3.1 Ammonia Equipment 3.1.1 Nature, Age and Condition 3.1.2 Testing Schedules 3.1.3 Maintenance Schedules 3.2 Sulfuric Acid Equipment 3.2.1 Nature, Age and Condition 3.2.2 Testing Schedules 3.2.3 Maintenance Schedules 4.0 Procedures Report 4.1 Ammonia 4.1.1 Daily Operating Procedures 4.1.2 Maintenance Procedures TABLE OF CONTENTS (Continued) Section 4.2 Sulfuric Acid 4.2.1 Daily Operating Procedures 4.2.2 Maintenance Procedures 5.0 Design, .Operating and Maintenance Control Systems 5.1 Ammonia 5.1.1 Design Control Systems 5.1.2 Operating Control Systems 5.1.3 Maintenance Control Systems 5.2 Sulfuric Acid 5.2.1 Design Control Systems 5.2.2 Operating Control Systems 5.2.3 Maintenance Control Systems 6.0 Detection, Monitoring or Automatic Control Systems 6.1 Ammonia 6.1.1 Detection Systems 6.1.2 Monitoring Systems 6.1.3 Automatic Control Systems 6.2 Sulfuric Acid 6.2.1 Detection Systems 6.2.2 Monitoring Systems 6.2.3 Automatic Control Systems 7.0 Proposed Risk Reduction Measures 7.1 Written Operating Procedures 7.2 Written Maintenance Procedures 7.3 Increased Inspections 7.4 Better Labeling 7.5 Safety and Training Program 7.6 Fire Prevention 7.7 Physical Plant Changes 7.8 Reduction of Risk to Neighboring Homes or Businesses TABLE OF CONTENTS (Continued) Section 8.0 Emergency Contingency Plans 8.1 General Evacuation 8.2 Fire 8.3 Earthquake' 8.4 Significant Leak from the Ammonia System 8.5 Significant Leak from the Sulfuric Acid System 8.6 Emergency Responders 9.0 Auditing Program 9.1 Ammonia System 9.2 Sulfuric Acid System 10.0 Inspection Program 10.1 Ammonia System 10.2 Sulfuric Acid System 11.0 Risk Management and Prevention Program (RMPP) Implementation 11.1 Personnel Responsible for RMPP Implementation 11.2 Implementation Schedule 11.3 Training Program for RMPP Implementation 12.0 RMPP Record Keeping 12.1 Accident Records 12.2 Ammonia Charge Records 12.3 Sulfuric Acid Charge Records 12.4 Training Records 12.5 Audit Records 13.0 Qualifications of Certifiers 13.1 Qualified person 13.2 Facility Operator References DB/jb 1619.0010A.004 · 4800 Easton Drive, Suite 114 Bakersfield, California 93309 }il~ji~/~c ~'/J/'~ Post Office Box 9217 Bakersfield, California 93389 805/326-1112 MY Q - 805/326-0191 FAX April 30, 1991 "'"'"-.. ~ nner /'~ " Ms. Barbara Bre Hazardous Mater_~anning Technician City uf BaKersfield Fire Department Hazardous Materials Division 2101 H Street Ba sfield, nia 93301 Re: PEPSI Risk Management and Prevention Program Dear Barbara: WZl Inc. has been selected by PEPSI to prepare their Risk Management and Prevention Program (RMPP). We propose to submit documentation based on the following time frame: August 1, 1991 Hazard and Operability Study September 16, 1991 Hazards Analysis November 29, 1991 RMPP If you have further questions, please call me. Very truly yours, David Butt Senior Engineering Advisor DB/jb. cc: 'D. Bridwe!l, PEPSI 1619.0010A.001 ' '" CITY of BAKERSFIELD "WE CARE" FIRE DEPARTMENT 2101 H STREET D. S. NEEDHAM BAKERSFIELD, 93301 FIRE CHIEF 326-3911 March 15, 1991 Mr. Robert E. Coleman Vice'President/General Manager Pepsi Cola Bottling Co. 215 E. 21st Street Bakersfield, CA 93305 Mr. Coleman: I received your time extension request'for the submittal 'of the qualifications for Pepsi's Risk Management and Prevention Plan preparer. The company which you select must submit their responses to the qualzfzcatzons questionnaire, which I sent earlier, by May 1, 1991. Please send all information regarding Pepsi's RMPP to me at: Bakersfield Fire Department Hazardous Materials Division 2130 G Street Bakersfield, CA 93301 'The individuals which you have Selected to assist the engineering consultant will be acceptable as study team members. Such a broad base of inhouse expertise will certainly be valuable to the production of a comprehensive Risk Management and Prevention -Plan, Please call anytime that I can be of assistance. Sincerely, Barbara Brenner Hazardous Materials Planning Technician .... cc.:.Ralph Huey ............ .. March 14, 199! Mi'sS larbar, a Brenner Hazardous. Materials. Planning Technician Dear Miss Brenner, __Thank .YOU. f~r .taking time .'out..._~o. explain to' .us the ~speci.fics z ..... regarding 'the Risk Management prevention, program (RMPP). The intent of. this letter is.to name Pepsi-Cola Bottling Company's in house RMPP team. They are as follows: · . Don Bridwell - safety Director Bili BentLeY - Production Manager " Kevin Phillips - Warehouse'Manager Barry'Lewis - Quality Control Supervisor We will 'aPpoi.nt and Provide'you' with-the name of the'Engineering Consulting firm that will aid us' by May 1, 1991. R'Ot.rt'-g~ Coleman Vice'President/General Manager REC:dh 215 East 21st.Street, Bakersfield, California 93305 ,'805/327-9991 · WATTS 1-800-821-2936 .ACUTELY ARDOUS MATERIAI. R STRATION FORM THIS FORM;MUST BE COMPLETED BY THE OWN~ER OR OPERATOR OF EACH BUSINESS IN CALIFORNIA WHICH AT ANY TIME HANDLES ANY ACUTELY HAZARDOUS MATERIAL IN QUOS GREATER THAN 500 POUNDS, 55 GALLONS OR 20C-~CUBIC FEET OF GAS AT STP. THIS FORM SHALL BE COMPLETED AND SUBIVIITI~D TO YOUR LOCAL ADMINISTERING AGENCY. (§25533 & 25536 Health & Safety Code) Note Instructions on reverse Business Mailing Address (if different) Business Phone (~::)~ 7~-7-~' ~] ~.,/ Business Plan Submission Dare2 ACUTELY HATARDOUS MATERIALS HANDLED4 -USE ADDITIONAL PAGES IF NECESSARY- CHFMICAI NAM;. · QUANTITY GENERAL DI=SCRIPTION OF PROC;SSES AND PRINCIPAL I=QUIPMENTS: SIGNATURE ~_.,(/-/'.~:"" TITLE ~,~ ://" PRINTED NAME ~a~X ~TO0 ~e~ DATE Cal~ornia ~i~ of Eme~e~ ~w~ FORM HM 3~ (1-15-88) INSTRUCTIONS: Superscripts:" 1. Quantities for RMPP compliance are "equal to or greater than" thc minimum criteria and apply to chemicals handled "at any one time".. 2. Businesses handling reportable quantifies of Acutely I-l~rdous Materials that have not submitted a business plan MUST contact local Administering Agencies. The business plan submission date will assure the Administering .Agency that a business plan has been submitted and is on file. This will also immediately identify businesses that have not submitted business plans. 3. "Process Designation" is provided as a reporting option (with the approval of the Administering Agency) for facilities flint can most easily report by process. Thus, facility RMPP registration data could be submitted in a similar format to a business plan that is divided by tnocess. "By process" dam can initiate an emergency response to a process incident rather than a general emergency response to a major facility. Process designation can simplify inspections for major facilities and improve future emergency response. 4. Refer to the EPA list of Extremely HaTardous Substances from the Federal Register (Volume 52, No. 77, p. 13397 et. sea_., April 22, 1987). Each chemical has a threshold planning quantity. This list may be changed by EPA on an annual basis. Updates of this list may be available early in 1988. To comply with this element, you may attach a copy of the inventory submitted to your Administering Agency from your business plan and highlight all Acutely Hazardous Materials. It is'recommended that facilities list all exlremely tmT~ardous chemicals handled in quantifies · equ,91' to or in excess of 1) 500 pounds, and 2) any EPA threshold planning quantity less than 500 pounds. 5. 'Do not include Trade Secret information in these descriptions. General: , ~ For emergency response purposes, it would be desirable to describe the following to the Administering Agency: 1. Batch Process: a. What raw materials? b. ' What operating pressure range? c. What operating temperature range? d. Batch capacity rating? e. Product characteristics? (e.g., chemical state, flammability, toxicity, etc.) f. Critical proce~ points and characteristics? 2. Continuous process: ( 'amilm information as above.) NOT£: "Pmsuant to §25534, lira Administering Agency may ~Xluire t~e submission of a Risk Management Prevention Program (RMPP), if the At~ninitmn~ng Agency denmnines that the handler's operation may present an acutely ba?arck)us materials aocident risk. The handler shall ~ the RMPP in accordance with subdivision (c) [of §25534]. The RMPP shall be prepared within 12 months following the request made by the Administea'ing Agency pursuant to this section." (§ 25534 (a) I-Iealth and Safety Code) An amendment to the RMPP must be submiued to the Administering Agency within 30 days of: 1. Any additional handling of acutely hazardous materials. 3. Change of address, business ownership, or business name. (§ 25533 (c) Health & Safety Code) · EVERY BUSINESS REQUIRED TO SUBMIT AN RMPP SHALL IMPLEMENT THE APPROVED RMPP · California Office of Emergency Services FORM HM 3777 (1-15-88) March 14, 1991 Miss Barbara Brenner Hazardous Materials Planning Technician Dear Miss Brenner, This letter is to confirm that Pepsi-Cola Bottling Company will be discontinuing the use of sulfuric acid by May 1, 1991. Sincerely, Robert E. 'Coleman Vice-President/General Manager REC:dh BOB\RMPP.let · 215 East 21st Street, Bakersfield, California 93305 · 805/327-9991 · WATTS 1-800-821-2936 ...... FIRE DEP.ARTMENT 210~ ~ STREET D. S. ~'4EEDHAM BAKERSFIELD. 93301 FIRE CHIEF 326-3911 Januaz'y '-'= ~, 1991 QUality Control Supervisor. Pepsi Cola Bottling Bakersfield, CA 93305 Thank you for coming by today to dlscuss Pepsi Cola's Risk Management and Prevention Program (RMPP), While you are welcome to submit the qualification's of inhouse stair as the proposed preparer~ of the ri~k management plan, be sure that tnese,~ ~ndividual~ have appropriate backgrounds. Thi~ Administering Agency ~.equimes that the hazard study team lnolude an inOiv~oual oF firm with engineering expertise, preferably both mechanical and chemical. The individual who certiiies the RMPP as complete must be experienced in the field~ of' risk assessment and icon~equence analysis. Qffsite consequence analysis must lnclude a&~ dispersion modeling. Ai~ dispersion of ga_e~ is based on complex mathematical calculation~ and is most efiectively performed by ~omputerized Of the 15 companies who have completed or are in Ithe 'procezs the analysis and RMPP document preparation. All ol companies with I refrigeration ~ystems have used professional consultants ~n addition to the experience of plant operations management and i - personnel. One major oil company was accepted as thle. qualified preparer of an RMPP for an ammonia blueprint system, ~owever they uti!&zed their research facll~ty for the air dispersion modeling. You certainly may present the qualiiicatlons ~I in house ~ta£f. However, unle~ Peps~'s has ~taii whose backgrounds vary ~ignlficantly from the personnel at other local lndu~t~lal plants, I suggest that you ~eek Profe~slcnal engineering assist[ante. Thank you fo~ '/ou~ attention in this matter. [ Sincerely, Barbara B~enneF ~ Ha~ar.d~us' Ma~als P~ann~ng Tecnn~an ~ , F~iS~. .~ .. 'J' r'-* c c ~': r' T T 0 J"d ~"~ i' S'r r '''q' v MCP 'S:, X I = S .... CrY k-'-'~C.i'~'iF! i--.I~Z~ ~!rSSE[i) ...... ,..., c; L-: k~ ['-' U , · FACILITY RISK INDEX RATING, W = Activities op conditions that increase the likelihood of a J x .5 : 1.5 (NO. OF YES ANSWERS ON THE QUESTIONNRIRE Add 1 yes to. each facility for s'tc>nag~ and minimal X = This fac%o~ r~eflect5 a company's claim (safety) history. '! .~7 (~ORKER COMP FACTOR, MAXIMUM EXPECTED IS Y = Self reported accident / safety record. 0.5 (REASONABLE=O, INADEQUATE=O,25, 6ROSSLY iNADEQUATE=¢.5 Z = A diAcr'etionary catagory used to account for factors not directly addressed in the questionnaire. (OI'HER COMPLiChTING F¢qCI'ORS MINIMaL=O, CONSIOERABLE=O.5, SUBSTANTIAL=I.O) FACILITY RISK iNDEX : 5.57 RATING F1 = W + X + Y + Z RATING RATIONALE: Risk increases with incr'easing process complexity and potential for human error, POPULAI'ION EXPOSED - RATING I. IS TOXIC MATERIAL APT TO BECOME ~IRBORN RAPIDLY ? i,e'. A GAS, FINE OUST, HIGHLY VOLATILE LIQUID NO=I YES= 2 2 IF ANSWER TO ~1 IS NO, PROCEED TO ~6 'IF ANSWER TO ~'1 IS YES, ESTIMATE THE EVACUATION R~DiUS, USING THE BhKERSFiELD FIRE DEPT. GRAPH MODEL, ~ND ANSWER QUESTIONS 2-5. 2. IS THERE A SCHOOL WITH IN THE EVRCU~TION RADIUS ? NO=O, YES='i 3. IS THERE A NURSING HOME OR HOSPITAL WITH IN THE EVACUATION RADIUS ? NO=O, YES=t 4. IS THERE RESIDENTIAL HOUSING WITHIN THE EVACUATION RADIUS ? NO:=O, YES=t 5. IS THE POPULATION DENSITY OF THIS AREA HIGHER THAN THE AVERAGE DUE TO ALOT OF MULTISTORY BUILDINGS NO=O, YES=I ~, WHAT IS THE OCCUPANCY OF THE BUILDING THAT AHM IS STORED OR HANDLED IN ? LESS TH~N S PEOPLE=t 8 - 25 PEOPLE =2 26 - SO.PEOPLE MORE THAN 50 PEOPLE =4 TOTAL POPULATION EXPOSED RATING = 8 RATING RATIONALE: Releases t;hat are ].imi'ted to onsite consequences NJ. ii lim~t the exposed population. As the number of persons onsit, e 'increases, evacua't. Lon and and r. espGnae efforts become mome complicated, and ~he potential for- injury FACILITY INFORMATION FORM Please ans~er each of the foilowin~ questions by.circ'~ng Y {yes) or N' (no). 1. Is any acutely hazardous material (AHM) manufactured or.used in a chemical remction o y / 2. Is any other flammable gas, flammable liquid . . or explosive material manufactured or used in a chemical reaction ~ Y / 3. Is any rea'ction ih question 1 or 2 a moderately or highly exothermic reaction ( e.g. alkylation esterfication, oxidation, nitration, polymerization or condensation) or one involving electrolysis 9 y / 4. Can any unplanned release of a AHM to the atmosphere result from the malfunction of any scrubbing, treatment or neutralization system or the discharge of a pressure relief system ? ~X]/ 5. Does any physical or chemical process in which an AHM is produced or used involve a batch process ? Y / 6. Does any physical or chemical process involve the production or use of any AHM at a pressure in ....~' excess of 15 psig~? ~/ 7. In excess of 275 psig ? Y 8. Does any physical or chemical process involve the production or use of an AHM at a temperature above 125 degrees F 9 Y / 9. In excess of 250' degrees ? Y 10. Can' any explosive dust be present in any closed container within 100 feet of an ARM or otherwise be present in the same building as an AHM ~ ' Y / 11. Is there any'ignition source or open flame within 100 ft. of any process, storage or transfer area where a flammable or explosive AHM is present , except where there is a firewall providing protection ~ Y / 12. Is any lined or non-metallic pipe used in the transfer of any AHM ~ Y / 13. Is any equipment or piping handling any AHM more ..~ 10 Years old ? ~/ PLEASE PROViD£ THE FOLLOWIXG INFOR>IATIO"4 ' ( Ar. tach additional pa~es it' necessary) 1. Your company's current workers compensation experience modification factor. 2. How many people occupy the building in which AHM.'s are used or stored 9 3. Give details of all accidents which involved any hazardous material and all other instances when the fire department has been summoned in an emergency. 4. Briefly described the operations process at your plant and the specific .processes utilizing AHM's, including storage proceedures. Ammonia is only used as a re£ridgerant in our can and bttle ~ine compressors; Bottle line= 350 lb Can line = 300 lb In resurve ='450 lb Total = ~%00~)Ib~ x 22.5 ft3 = 2~750 ft3 -2- 5. Briefiy describe the equloment bein~ used in the p~'ocess~s invoivin~ AH~Is. The °nly major equipment used in the manipulation of ammonia is the compressor. 6. Report quantity of AHM(s), referenced in the cover letter, that this business handles. a) Maximum amount On hand at any one time. 24,750 ft3 b) Please attach a Material Safety ·Data Sheet for any material that is a mixture. Do not include MSDS for pure substances. DEMOGRAPHIC DATA: State the straight line distance in feet between the business property line and each of the following. 1. Nearest school. 164 ft 2. Nearest daycare center, hospital, 5,249.34 ft nursing home or similar facility. 3. Nearest residence/motel etc. approx. 10 ft 4. Nearest occupied building, approx. 10 ft Business Name: PEPSI COLA BOTTLING CO. Address: 215 E ~1 St. Bakersfield Ca. 93305 I certify that 'th~ foregoing information is true and correct to the b~/~ my knowledge. Title: Quality Control Supervisor Date: t~/76/90. -3- /' 805-32?-3669 ~KERS WELDING BKSFD 8?4 PO1 NOV' 21 '90 16:07 MATERIAL SAFETY DATA'SHEET (Essentially similar to U.S, Del3artment of Labor Form OSHA-2Ol ..... Do Not Oupl/cate Th/$ Form. Request an Or/g/ne/ PRODUCT Ammonia,' Anhydrous (Liquefied Gas Under Pressure) CHEMICAL NAME Ammonia, Anhydrous SYNONYMS Liquid Ammonia :':' ~'~3-RM'U LA NH3 CHEMICAL FAMILY Alkaline'Gas ' TRADE' NAME AND SYNONYMS - - - MOLECULAR WEIGHT 17.031 For mixtures of this Refer to Section V for TLV informatlol~.terial Date Sheets. ' "'." · 'BOLLING POINT, 760 mm. Hg -33,35'0 (-28°F) FREEZING POINT -77.7°C (-107.g°F} SPECIFIC GRAVITY (H20 = 1~ 0.62 (15°C) VAPOR PRESSURE AT 20°C, 128.8 psia SO LUBI LtTY I N Appreciable VAPOR DENSITY (air = 1) 0.597 WATER, % by wt. PER CENT V© LATI LES 100 EVAPO R ATI'dN' RATE High .B.Y_ VOLUME. .. (Butyl A0eta_t~ = 1} ............ . ........ APPEARANCE AND ODOR Colorless, pungent, irritating odor. i,.' .... FL'AsH POINT Flammable Gas tAUTOIGNITION 637ec (1204eF) !::,'~"~."~:i "lL' .'.(.,~:imethod) ...... , TEMPERATURE :'~: LAMMAB LE LIMITS ' I LOWER ] u'PP~[-R ............ · !~N~.._A_U~o % by vol ume 15% 28% EXTINGUISHING MEDIA CO2, d~ chemical, water spray or fog," ' ........ ~PECIAL F~ ~E-~ i~HT'i~G PROCEDURES ....... Evacuate all personnel from danger area, Do not approach area without seif-con~in~ breathing'apparatus and proactive clothing. Immediately cool ~ntainers with water spray from maximum distanm ta~ing ca~e not to extinguish flames. Remove ignition if widget ri~k. tf flames are ~[dantally extinguished, explosive re-ignition may oc~r, Redu~ corrosive va~rs wi~ water spray f~. Stop flow of gas if without risk while continui~ cooling water spray. Remove all ~nta~ners from area of f~re if w~out risk. AII~ fire to burn out, ~NUSUAL FIRE AND EXPLOSION HAZARDS " Fl'am~ble, toxic, ~rrosive gas. Forms expl~Ive mixtures with air and oxidizing agent. ~ntainer may rupture due to heat of fire. ~ not extinguish flames due to ~ssibility of expl~ive re-ignition, Flammable and corrosive va~rs may spread from spill Explosive atmospheres may linger. Before on.ring area, especially confined a~s, ~eck a~os~here with appropriam devil. No ~ of a ~ntainer should ~ subject~ to a temperature higher than 52eC {a~roximately IN CASE OF EMERGENCIES involving this material, further information is available at all tlr~es at th~s telel3hone number: '"'" '~ 304:744-3487 <.' ,. j For routine information contact YOur local Linde Supplier, . ~1 'V~Thile ~Jnion Carbide Corporation believes that ~he-d-~-ta =0ntai~ed herein m'a factual and the opl~i~)~s e~presr~'m'e those of qualifi~-axperta - ' ' regarding the tests ~onducted, the data are not to be taken aa a warranty or representation for which Union Carbide Corporation legal refl~onslbility. They ara offered s~lely for your ¢on~ide'ratlon. investigation, and verification. Any USe Of these date and information must be LI~ determined by the user to be in accordance with appticable Federal, State. and local laws and regulations. · · ~_- 805-327-~669 WELDING BKSED 8?4 PO~ NOt) 21 .'90 16:07 "PROD, O~T': ' Ammonia, Anhydrous (Liquefied G~ Under Procure) LIMIT VALUE TLV.~A: 25 ppm (18 mg/m3) {ACGIH-1978) · EFFECTS~OF OV~RE~P0~'~' AND EMERGENCY AND FIRST AiD P~0CEDURES " ~n ~use.e~ma of respiratory tram, ~phyxiation. Can ~rn eye, lugs'and skin. ~f iq~aled, remove to fresh air, If not breathing, give artificial respiration, If breathing is difficult, give oxy~n. Call a physician, In.~ef..~nta~ with ~quid o~ vapor, immedia~ly flush areas of ex,sure with large quantitie~ of water while removing . eon~.amln~ clothing and shoes, ~11 a physician, ~ntinue to flush with water fo~ at leas~ 15 minute or until medical a~ntlon ' b..o~ined. Dlsca~ con.minuted clothing and shoes, ;.~ ..B~to[e[t~a to normal ~dy temperature (98.6 Fl as rapidly as possible followed by prom~mn of the injured U~ue from ~her '~ma~):~n~mfem~on. Call a physician. Rap~d warming o~ the afield part , ~ir~msta~ should the water ~ over 112~F, nor sh~ld ~he frozen pa~ be rubbed ei~e~ ~fote of a~er re-warming. The patient · ~oaid.net'smoke, nor drink al~hol. Keep warm and at · ..:S~BILITY CONDITIONS TO AVOID · ;" Unst~l~le ~ Stable See Section IX. .i/_' ~ · ,....... :,::,:.;.. ~ :,' ~'. , X ................ i'!~"IN~C_O'M.,P~TIBILITY- ~ ~ (ma~erials t~ av'oid) Silver mercury, oxidizing agent, halogens, ~s, brass (~pper). [~,}~R~D'e~S DECOMPOSITION'PRODUCTS' ' ..... ."' ........ .~ ~ ~ · ' . None .'::.. ~~'eOUS POLYMERtZATION coNDITIONS TO ,~~Io'~%r. · wit~ .o~ Occur · X '"~TE~'~-:TO BE T~KEN IF MATERIAL IS RELEASED OR SPILLED · Immediately'evacuate all personnel from danger area. ' WARNING: Flammable, corrosive, toxic gas, Forms explosive mixtures with air (see' Section ~V~. Use self-contained breathing apparatus and protective clothing where needed. Remove all sources of ignition 'if without risk, Reduce vapors with fog or fine water spray. ' ,Note; Suck-back into cylinder may cause explosion (~e Section iX). Shut off leak if without risk. Ventilate area of leak or move · : l.esk!ng:container to well-ventilated area. Prevent run-off from contain|naming surrounding environment. CAU3;ION; Flammable, corrosive, toxic vapors may spread from spill. Before entering ama, especially confined areas, check atmosphere with appropriate device. ~;.., WASTE:'~'ISPOSA L METHOD ........ "-- ' ......... 'i'~!,'~i .... ':' .' Ammonia, Anhydrous (Liquefied Gas Under Pressure) F4562 ¢~i~.i}'~ .;- R."ATORY PROTECTION (specify type) i'..'..-':":?'S'If'c~n'~ined breathing apparatus where needed. ~: ~'"' ' LOCAL EXHAUST ;!..,...,~ : ;~:'..~ Exploson-proof, corrosion resistant system is acceptable. .~.: ,! ~;.! ¥ - ...... ..,. , ... MECHANICAL (general) . ' VENTILATION Inadequate , :~i!:' SPECIAL Explosion-proof, corrosion resistant, forced dr;~t fume hood is preferred. OTHER .~;:' - P. ROTECTIVE G LOVES Neoprene · ' .EYE PROTECTION Safety glasses and a full face shield. : · O'T,:HER PROTECTIVE EQUIPMENT Metatarsal shoes for cylinder handling. Protective clothing where needed. I: .' WARNING; Toxic, corrosive~ flammable, liquefied gas under pressure. Do not breathe gas. Do not get liquid or vapors in eyes, on skin or clothing (see Section V). Safety showers and eyewash fountains should be immediately available. Use piping and equipment adequately designed to withstand pressures to be encountered. May form explosive mixtures with air. . ,,. 'Keep away from hea~, sparks and open flame. Ground all equipment. Only use spark-proof tools and explosion-proof equipment. "!;* Store and use with adequate ventilation at all times. Use only in a closed system constructed of corrosion-resistant materials. Close valve when not in usa and when empty, :'..' Suck-back into cylinder may cause explosion. Always use a vacuum break or other protective apparatus in any line or piping from the :..". cylinder to prevent suck-back, oTHER HANDLIN(~ AND STORAGI5 CoI~DITIONS ........... ' ......... TOX Ff:~C'f'OR ,;I...1{'~ Bf¥SED C,N DEGREE B" .... ;:{ ~ =: '7. WHICH T'PC' 15 Frx'n~::E:DEn FACILITY RISK INDEX RATING Activities or conditions that increase the likelihood of a release. 3 x .S = NO. OF' YES ANSWERS ON THE QUESTIONNAIRE '1-15. Add '1 yes to each facility'for, stor'age and handling. ) X = This factor i~eflects a company's'claim (safety) history'. t .07 (WORKER COMP FACTOR, MAXIMUM EXPECTED IS Y = Self reported accident / safety record. 0 · (REGSONABL. E=O, INGOEQUATE=0.25, GROSSLY !NGOEQUATE=O.5) Z = 8 discretionary catagory used to account for factors not directly addressed in the questionnaire, 0. S TI,,,"-, ~o'(,'",'~" .~.~s.~ '~-~'~ ~o~¢~. No ~ ~'~ (OTHER COMPLICATING F~CTCR= ~N~:~i~L=e, CONSIOER~SLE=e. S, SU8STm~TZaL= ~. 0 >~L~. ~ . FACILITY RISK INOE× = 3.07 RATING FI = W + X + Y + 'Z RATING RATIONALE: Risk increases with increasing process complexity and potential for. human er'cot'. POPULATION EXPOSED - RATING 1. IS TOXIC MATERIAl_ APT 'TO BECOME AIRBORN RAPIDLY i.e. A GAS, FINE DUST, HIGHLY UOLATILE LIQUID NO=I YES= 2 IF RNSWER TO ¢1 IS NO, PROCEED TO ~6 IF ANSWER TO ~t IS YES, ESTIMATE THE EVACUBTION RADIUS, USING ]'HE BAKERSFIELD FIRE DEPT. GRGPH MODEL, ~ND ~NSWER QUESTIONS 2-S. 2. IS ]'HERE A SCHOOl_ WITH IN THE EVACUATION RADIUS ? NO=O, YES=I 1 3. IS THERE ~ NURSING HOME OR HOSPITAL ~ITH IN THE EVACUATION RADIUS ? NO:=0, YES=I 0 4. IS THERE RESIDENTIRL HOUSING ~ITHIN THE EUACu~-rlON RRDIUS ? NO=O, YES=I .'~' ~. IS THE POPULGTION DENSITY OF THIS AREA HIGHER 'fH~N THE ~UERAGE DUE TO ~LOT OF MULTISTORY BUILDINGS NO=e, YES=I 6. WHAT IS THE OCCUPANCY OF THE BUILDING THAT AHM IS STORED OR HANDLED IN ? LESS THGN 5 PEOPLE=I 6 -25 PEOPLE =2 26 - ~0 PEOPLE =3 MORE THAN 50 PEOPLE =4 TOTGL POPULATION EXPOSED R~TING = "~.I~"~ RSTING 'R~TION~LE: ' Releases tha't are limited to onsite consequences, w~ll limit the exposed popula'~ion, Rs the number o¢ persons onsite increases, evacuation amd and response efforts become more complicated, and the potential Cot injury SULFURIC ACID (H2S04) FACILITY INFORMATION FORM Please ans~er each of the fo£i,awin~ questions by .circlin~ Y (yes) or N (no). 1. Is any acutely hazardous material {AHM) manufactured or used in a chemical reaction o ·~/ 2. Is any other flammable gas,. flammabie liquid or explosive material manufactured or used in a chemical reaction v Y / 3. Is any reaction in question 1 or 2 a moderately or highly exothermic reaction ( 'e.g. alkylation esterfication, oxidation, nitration, polymerization or condensatiOn) or one involving electrolysis 9 y / 4. Can any unplanned release of a AHM to the atmosphere result from the malfunction of any scrubbing, treatment or neutraliza'tion system or the discharge of a pressure relief system ? / 5. Does any physical or chemical process in which an ANM is produced or used involve a batch process ? Y / 6.' Does any physical or chemical process involve the production or use of any AHM at a pressure in excess of 15 psig * Y / 7. In excess of'27§ psig * Y / N~ 8. Does any physical or chemical process involve the production or use of an AHM at a temperature above 125 degrees F ~ Y / 9. In excess of 250 degrees ~ Y / N~ 10.Can any explosive dust be present in any closed container within 100 feet of an AHM or otherwise. be present in the same building as an AHM ? .Y ll. Is there any ignition source or open flame within 100 ft. of any process~, storage or transfer area where a flammable or explosive AHM is present , except where there is a firewall providing'protection ~ Y / 12. Is any lined or non-metallic piPe used in the transfer of any AHM ~ ~/ / 13. ISl0 any years equipment old ~ or piping handling any AHM more Y / PLEASE PRoviDE THE FOLLOWING INFOR)IAiIO"4 · ( Attac'n additional pages it' necessary} 1. Your company's current workers compensauion experience modification factor. 107 2. How many people occupy the building in which AHM's are used or stOred ~ NA 3. Give details of ail accidents which involved any hazardous material and ail other instances when the fire department has been summoned in an emergency. NONE 4. Briefly described the operations process at.your plant and the specific processes utilizing AHM's, including storage proceedures. The sulfuric acid used at our .facility is part of our waste water neutralization process. The city,s requirement is that our waste water have a ph no less than 6.0 and no greater than 10.0. Our waste water sys~em~'~:s~des~gned to electronically detect the ph of the waste water. If the ph of the water is too alkaline, then the system will automatically inject a certain amount of acid in order to keep it within city standard (6.0- 10.0). The storage process, like the sodium hydroxide, is in ~ acid resistant,.700 gallon tank surrounded by a holding area large enough to contain the volume of the tank in the case of a spill or leak.. 5. Briefiy describe the e~uioment bein~ used in ti~e processes invo£vin~ AH~Is. ' -The 700 gallon storage tank i.s attached to a~D4 metering pump which, as a'result of electronic signals, will pump acid in-a large tank holding the waste water. 6.' Report quantity of AHM(s), referenced in the cover letter, that this business handles. a) Maximum amount on hand at any one time. 500 gallon b) PleaSe attach a Material Safety Data Sheet ~ 6~o 93? for any material that is a mixture. Do not include MSDS for pure.sUbstances. DEMOGRAPHIC DATA: State the straight line distance in feet between the business property line and each of the following. 1~ Nearest school. 164 ft. 2. Nearest daycare center, hospital, nursing home or similar facility. 5,249.34.ft. 3. Nearest residence/motel etc. ~ approx. 10 ft 4. Nearest occupied building, approx. 10 ft Business Name: 'PEPSI COLA BOTTTJNG CO. Address: 215 E21 St. Bakersfield Ca.. 9.3305' I certify that the foregoing information is true and correct to the be~f my kn,owled~e. Signature: ' . ~ ~.,~.// ~ Title: Quality .Control Supervisor Date: 11/26/90 -3- M A '[ E R I A L S A F E T Y D A T A S H I~ E T PASE ~ OF 5 tlUl.ll)t] CHEI'TICAL I'I~;C. P,O, BOX ~951 BAI=;EF~Si:'IELD~ CA. 9558~ (805)-58~-22~0 EFFEC~'IVE DATE: 5/2/85 PRODUCT EOD~: SUI_~URI~ ACID ~J~ SECTION I iDENTIFICATION PRODUCt HAI.IE~ SULFURIC AC~D ~.~% HSD: B- 58 ~HEHI~AL NAME: SUi_FIRIE ACID ~:5'& FO[iHt.IL A: H2S04 DOT ~'~ttJPPING ~AHE: SULFURIC ACID DOT PLACARD: UNISSO DOT HAZARD CLASS; CORROSIVE HRTERIAL LA~EI.:COI~ROSIVE SECTION 2 DESCRIPTION AND PHYSICAL DATA A, APPEARANCE (INCLUDE PHYSICAl. STATE, COLOR, AND ODORS.): [:[.ERR ~0 t~A'[ER WHITE LIQUID WITH AN ACRID ODOR. B. ilAZARDOUS INGREDIENTB: Nt~I~E I=:NOtqN ~. [~OL.UBII_ITY IN HATER: 100% D. ~P. GRAVITY~ t.a~ E. % VOi. AT]L.E BY I,JEIGHT: APPRECIABLE % F. pH: 1 SECTION 5 HEALTH HAZARDS TOXICITY AND IRRITANCY: ~. ACUTE ORAL LD50: ~ mg/cm 2. SKIN: RAPID' AND SEVERE CORROSIDN OR BURN ADTIDN 5, EYE: VERY SEVERE ~i.~l.:llOl~ 4 EMERGENCY FIRST AID St~'.IN: EI. USH WITH' LARGE AHIIJNTS OF IdAIER FGR 15 MINUTES OR ~ORE. EYES: FLUSIt Hi'Ill LARGE AIIIUN'tS OF WA'I'Ei~ F[)R 15 IflINU'IES OR I,iORE, SEEK /1EDICA HELF', II'~GESTED: I)0 t~OT INDUCE VGIIITIN~, SEEK MEDICAL IfELP. C~EL;IION 5 FIRE AND EXPI.CI~IVE ltAZf~RD DATA A. PY~Ot:'OR I C: NO B, I.IQIJID: FLASH POINT: N,R, oF I'IETHOD USED: N.A. C, SOL I D: N, A. FLAMMABI .E N, A. NON FLAMMABLE D. FIRE ~XTING[JI~I411,JG HEDIA (~HECK ALL WlffI~H AR'E APPI_ICf~BLE)= N. A, i4A'rER N.A. DRY C:HEMICAL N- A. CARBON DIOX ].DE N. A, FOAt E, HAZARDOUS THERHAL DECOHPO~ITION ~i~ODUCT~: I{YDR'OGEN ~A~ AND HIGHI. Y '~OXI~ FUME~ ~F SUI. FUR OXIDES C;Ot4CENTRATED ACID CAN IGNITE COHBUST[BLE MATERIALS ON CONTACT. ~ 11/01/1990 10: CHEMICAL BKFLD CA. 14705505 P.06 M A T E R I A L S A F E T Y D A T A $ H E E T PRODUCT C()DE:SULFURIC ACID ~3% HDNDD CHEMICAL INC. PAGE 2 oS 5 MSD: B- 58 SECTION ~ REAC¥IVITY A. UHECK BELOW THE STATEMENTS WHICH APPLY TO P~ODUCT.: Z. XXXXXX IS NORMALLY STABLE 2. XXXXXX YIELDS OXYGEN OR OTHER STRONG OXIDIZING CASES THAT MAY PROMOTE THE COMBUSTION IN OTHER MATERIALS 5. blILL VIGOROUSLY POLYMERIZE, DECOMPOSE DR CONDENGE 4. XXXXXX REACTS VIGOROUSLY WITH WATER 5. IN THE FORM OF A DUST AND MIXED WITH AIR IN THE PROPER PROPORTION CAN BE EXPLOSIVE B. LlST BELOW ANY KNOWN INC~HPATIBILITIES (MATERIALS TO BE AVOIDED)m REACTS VIOLENTLY WITH WAlER AND ORGANIC MATERIALS WITH THE EVOLUTION OF HEAT SECTION 7 SPILL OR LEAK PROCEDURES A. STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED~ 'I'REA TWITH CAUTION. NEUTRALIZE WITH WITH.SODA ASH OR LIME AND FLUSH WITH WATER. IF WATER. IS NOT AVAILABLE COVER WITH SAND ASHES OR GRAVEL AND NEU'[RALIZE WITH SODA ASH. DO NOT USE COMBUSTIBI.EB SUCH'AR CLOTH OR ~AWDUST FOR MOPPING UP. S. WAS~ DISPOSAL METHOD~ DILUTE AND NEUTRALIZE. POUR A~ID INTO WATER NEVER ADD WATER TO ACID. DISPOSE OF ~CCORDIN~ TO STATE AND FEDERAL ~E~ULATIONS. SECTION 8 SPECIAL PROTECTION INFORMATION A. .~ESPIRATORY PROTECTION (SPECIFY TYPES) m FOR ENCLOSED AREA~: ~ELF CONTAINED BREATHINO APPA~A'FUS. B. VENTILATION: N()RMAL, DO NOT INHALE FUMES, AVOID BREATHING VAPORS, C. EYE F'I~OTECT I ON~ CI.IEM I CAL GOGGLES D. Pi~O'F£~ l VE GLOVESm I~UBBER E. OTHER PROTECTIVE EQUIPMENT: CHEMICAL RESISTANT CLOTHING AND BOOTS IJSER'8 RESPONSIBILITY: A bulletin such am thim cannot be expected ko cover all pi~sible individual situations. As [ha ua~r has Ibm Kesponsibility ~ provide .a ~a~e ~oKkplace, al} aspects ~-an individual opeFa[ion ~hould be e~amined determine if, or where, precautions, in addition to II,oma described herein, are required.. Any health llazar'd and safety information contained herein should be pa~ed on to your employees or contractors~ as the ca~e may be. HONDO -' il/01/1990 ~HONDO CHEMICAL BKFLD CA. 1470S505 P.O? MATERIAL SAFETY DATA SHEET F'~ODU~T CI]DE: SULFURIC ACID ¢~5% HONDO CHEMICAl. INC. PA~E 5 ~{ MSD: B- 58 rely on the user to u[ilize the in{ormation we have supplied to develop work practice guidelil~e~ and empioy~ instructional programs {or the individual operation. DISCLAIe~ER OF LIABILITY: As ~he ~.~l~ndif. ions or me,hods o~ use are beyond our control, ~ do no~ assume any responsibility and e~pr~ssl¥ disclaim any l~abilitv ~or any l~se o{ this mat~rial~ In~ormation contai~ed heFein is believed ~o be t~ue and accurate but all s~a~ements or suggestions are made wi[hoUr warranty, express or implied~ regarding accuracy o~ ~he info, marion, the hazards co~nected with the us~ ~ ~he material or ~he results ~o be obtained {rom ~he use ~hereo~. Complianc~ wi~h all applicable ~eder&l, sta~e and local laws and r~gula~ions remains the r~sDonsibilit¥ of the user. ...CITY of BAKERSFfELD FIRE DEPARTMENT D S. NEEDHAM 2101 H STREET FIRE CHIEF BAKERSFIELD 93301 · . 326-391 November 29, 1990 Dear Mr. Lewis: Your business Pepsi Cola Bottling, located at 7301 District Blvd, has been identified as a handler of. acutely hazardous materials. It has been determined that your operation may present an acutely hazardous materials accident risk. Therefore, pursuant to section 25534 of the California Health and Safety Code, you will be required to submit a Risk Management and Prevention Program (RMPP) for the use and handling of anhydrous ammonia and sulfuric acid. The RMPP shall be based upon a risk'assessment Which shall consider ail of the following: THE RESULTS OF A HAZARD ANALYSIS WHICH IDENTIFIES THE HAZARDS ASSOCIATED WITH THE. HANDLING OF AN ACUTELY HAZARDOUS MATERIAL DUE TO OPERATING ERROR, EQUIPMENT '" 'FAILURE AND EXTERNAL EVENTS WHICH MAY PRESENT AN ACUTELY HAZARDOUS MATERIALS ACCIDENT RISK. FOR THE HAZARDS IDENTIFIED IN THE HAZARD ANALYSIS, AN OFFSITE CONSEQUENCE ANALYSIS WHICH ASSUMES PESSIMISTIC AIR DISPERSION AND OTHER ADVERSE ENVIRONMENTAL CONDITIONS. The RMPP shall include the following elements: A DESCRIPTION OF EACH ACCIDENT INVOLVING ACUTELY HAZARDOUS MATERIALS WHICH HAS OCCURRED AT THE FACILITY WITHIN THREE YEARS FROM THE DATE OF THIS RMPP REQUEST. THIS DESCRIPTION SHALL INCLUDE THE UNDERLYING CAUSES OF THE ACCIDENT AND THE MEASURES TAKEN, IF ANY, TO AVOID'A RECURRENCE OF A SIMILAR ACCIDENT. A REPORT SPECIFYING THE NATURE, AGE AND CONDITION OF THE EQUIPMENT USED TO HANDLE ACUTELY HAZARDOUS MATERIALS AT THE FACILITY. INCLUDE SCHEDULES FOR TESTING AND MAINTENANCE O~ THIS EQUIPMENT. ,DESIGN, OPERATING AND MAINTENANCE CONTROLS WHICH MINIMIZE THE RISK OF AN ACCIDENT INVOLVING ACUTELY. HAZARDOUS MATERIALS. DETECTION, MONITORING OR AUTOMATIC CONTROL' SYSTEMS WHICH MINIMIZE THE POTENTIAL RISKS POSED BY ACUTELY HAZARDOUS MATERIALS ACCIDENTS.. IN RESPONSE TO. THE FINDINGS OF THE RISK ANALYSIS., " ADDITIONAL STEPS TO BE TAKEN BY THE BUSINESS IN ORDER TO REDUCE THE RISK OF AN ACCIDENT INVOLVING ACUTELY HAZARDOUS MATERIALS. THESE ACTIONS MAY INCLUDE ANY OF THE FOLLOWING: INSTALLATION OF ALARM, DETECTION, MONITORING OR AUTOMATIC CONTROL DEVICES. EQUIPMENT MODIFICATIONS, REPAIRS OR ADDITIONS. CHANGES IN THE OPERATIONS, PROCEDURES, MAINTENANCE SCHEDULES OR FACILITY DESIGN. THE RISK MANAGEMENT AND PREVENTION PROGRAM SHALL IDENTIFY, BY TITLE, ALL PERSONNEL AT THE BUSINESS WHO ARE RESPONSIBLE FOR CARRYING OUT THE SPECIFIC ELEMENTS OF THE RMPP AND A DESCRIPTION OF THEIR RESPECTIVE RESPONSIBILITIES. THE RMPP SHALL INCLUDE A DETAILED TRAINING PROGRAM TO INSURE THAT THOSE PERSONS ARE ABLE TO IMPLEMENT THE RMPP. ~ AUDITING AND INSPECTION PROGRAMS DESIGNED TO ALLOW THE .7... HANDLER TO CONFIRM THAT THE RISK MANAGEMENT AND PREVENTION PROGRAM IS EFFECTIVELY CARRIED OUT. "'].-' RECORD KEEPING PROCEDURES FOR THE RISK MANAGEMENT AND PREVENTION PROGRAM. THE'ACUTELY HAZARDOUS MATERIALS HANDLER 'SHALL REVIEW THE RISK MANAGEMENT AND PREVENTION PROGRAM AND SHALL MAKE NECESSARY REVISIONS TO THE RMPP AT LEAST EVERY THREE YEARS. REVISIONS SHALL BE MADE WITHIN 60 DAYS FOLLOWING A MODIFICATION.WHICH WOULD MATERIALLY AFFECT THE HANDLING OF AN ACUTELY HAZARDOUS MATERIAL. The CA Health and Safety Code provides businesses 12 months, from the date of request, to complete and implement a RMPP. The Risk Management and Prevention Program, and any. revisions to it, shall be certified as complete by a qualified person and the facility operator. It usually takes a business several months to locate a qualified company or individual to carry out the hazard analysis. It then takes several more months to have the plan's various elements reviewed by-this Administering Agency and to complete the RMPP. The attached questionnaire regarding the qualifications of the R~IPP preparer should be submitted to this A~enc3- by March 1. 1991. Upon approval of the RMPP preparer, we 4i2t agree to a schedule for the completion of the hazard analysis and RMPP. The finisHed'RMPP will be due on November. 29, 1991 All submittals regarding this RMPP shall be ma~e to: The Bakersfield Fire Department 2130 G Street Bakersfield, CA 93301 If I can be of any assistance please feel free to call. I can be reached at 326 3979. Sincerely, Barbara Brenner }tazardous Materials Planning Technician NOVEMBER 26, 1990 Bakersfield Fire Department Barbara Brenner, Hazardous Material Planning Technician 2130 G Street Bakersfield, CA 93301 Dear Ms. Brenner~ I am responding to your inquiry regarding, our inventory of acutely hazardous materials (AHM). Since March 1988, there have been no · ' significant changes in the total amount on hand at any one time. I have taken..the time to inspect the various departments such as Vending, Fleet and Maintenance, Warehouse, and other areas and found no reportable quantities, i.e., not.greater than or equal to 500 lbs, 55 gallon liquid, or 200 Ft3. However, there has been a new facility added which is currently utilizing AHM in the form of a chemical reaction. This is our recently installed-Waste Water Treatment facility. In complying with the City of Bakersfield requirements, we were instructed to develop a system to maintain a waste water ph level of 6.00-10.OO. In doing so, we are currently using sulfuric acid (H2SO4) and caustic soda (NaOH) to neutralize our waste water to comply with City of Bakersfield requirements. Please see additional information attached. As far as our total quantity of ammonia is concerned, we have updated or made corrections based on the total amount on hand at any one time. The report we submitted in 1988 states that we have 5 tanks of ammonia of 150 lbs. each. Based on my recent investigation, we have a total of 350 lbs on the bottle-line, 300 lbs on-the can line, and 450 lbs on reserve. This qives a total of 11OO lbs.% times 2~~ equals 24,75OFt3. The quantity reported in 1988 was 1~,875Ft3 which reflects an increase of 7,875Ft3. 2! 5 East 21st Street. Bakersfield. California 93305 ' 805/327-9991 ;. V~/^TI'S 1-800-821-2936 Page 2 Please see attached information for general description of process. . I have enclosed the following: 1. MSDS For a. Anhydrous Ammonia (NH3) b. Sulfuric Acid (H2SO4) c. Caustic Soda d. Blueprint copy of the facility and locations of AHM's, demographics of nearest hospital, nearest school and nearest occupied buildings. Please let me know if you have any further questions or concerns. Sincerely, Barrington Lewis Quality Control Supervisor BL~cu Enclosures · .' CITY of BAKERSFIELD "WE CARE" , · · ~" ~ _.-~,; D. S. NEEDHAM BAKERSFIELD, 93301 FIRE CHIEF 326-3911 October 26, 1990. Mr. Kevin Phillips O~era~ions Manager Pepsi Cola BDt%lin9 Co~ 21S E. 21st Street ... Bakersfield, Cfi B~OS .~ .-.':: ~>::.~..~:.~.( .. :? ._::~:..'~...~.~?- 'Oear ~r. Phillips, '- Inclosed is a copy of ~he acutely hazardous ea~erials' registration for~ ~hi~h ~as filed in ISBB regardin9 the use of anhydrous ammonia at ~he Pepsi plant. I~ was not included in print ou~ of the b~ness plan ~hich I gave you during inspection, but ~ay~seful in .your-'planning activities. con~acted Eric Pore Of ~he Bakersfield Building I ~iI1 be able to use ~heir r~¢ord~ to revie~ Pe~i'~ facility plans. I want to make certain ~hat you understand ~the reporting requireMents.regarding releases or spills of hazardous ~ release of any hazardous material that is a threat to life,. health or the environment or exceeds the reporting requirement.of' SS gallons, S00 pounds or 200 cubic fee~ mus~ be reported to the local ~dministering ~gency and the California Office of. Emergency Ser¥ices. You can contact these agencies at: 8akersfield Firs Oepar~en~ Hazardous Materials Division 2130 6 Stree~ Bakersfield, C6 S~01 '- 326-~97g California Office. of EMergency Services. 2800 Meadowview Road Sacramento, Cfi 9S8~2' 1-800-852-7550 P~GE 2 Please share this information with the other menagers who will be 'responsible for hazardous materials reporting. Thank you' for your cooperation in the completion of the hazardous material~ reporting requiremen~ for Pepsi CoLa. Sincerely, . 'Berbmra Brmnner . Hazardous. Materials Planning Technlcian .~ .... - .......:/~'..-.~ ~ ........ ...... :~.' ~:~ ]. . . ~, : . - '-' - '-'- - " .-'. ~ '-~?':~..~' K'r:'~Z~':%~ ~ : ~'~,'::':d?:~< '~' ~:'"' ':~.] . ' . .-.. '-:- ~"-...... ~/..~ '-~ .. . . ,... ~ '~ ... ,:' '~.,.y... 5705 INDIAN WELLS AVENUE BAKERSFIELD. CA 93309 HARRY R. FEDER CONSULTING GEOLOGIST MAR 0 ? I.,,.:3 March 5, 19.90 CITY OF BAKER3F:2LD PLANNING DEPARTM¢-NT Russell Turner Assistant Planner City of Bakersfield .. 1601 m~v+,,~ ~vonue Bakersfield, CA 93301 Re: Letter. addressed to Powell of Simpson-Vancuren, Inc. entitled Evaluation of Geologic Report .for Tentative Tract 5149 'in Accordance with Alquist- Priolo Special Studies Zone. Refers to my report entitled Alquist-Priolo Special StUdies Zone and Engineering Geology Report on Tract 5149 in 1989. Dear Mr. Turner: The following is given in reply 'to the above indicated letter by numbered section: 1. Paragraph 1 - "Lineaments on photos, 1981, appear to be structural." They are not structural for the following reasons: November 1952 photos do not show any lineaments. near Tract 5149. None of the surface cracks or "mole tracks" of the 1952 Arvin-Tehachapi earthquake in tha Ant Hill area were 'visible by the end of 1952. They did not affect the asphalt paving on Highway 178, whereas movement on both the White Wolf and Garlock faults ruptured paved roads. The surface cracks conform to no known faults and cut at random across topo- graphic.features. They are considered to be the result of earth-lurch against rising granite base- ment. The ruptures are no more faults than is displacement in a landslide. Northwest in Section 9,. 2600 feet of trenches were dug by me in the Alquist-Priolo Zone. No faulting was found. The open trenches were checked by Lyle Timberlake, ; County Geologist; and Henry Walrond, Consulting Geologist. .. CERTIFIED ENGINEERING GEOLOGIST The active Kern Gorge fault is the focus of earthquakes of minor magnitude during~the past several years. The White Wolf fault, 14 miles southeast continues to be active since 1952 when the 7 to 7.9 magnitude Arvin-Tehachapi earthquake occurred with epicenter 25 miles southwest of the Site. A Richter magnitude 7~3/4 earthquake on the White Wolf fault may occur every 200 years Acceleration ~of gravity in bedrock may be.0.5 during this event and greater in overlYing~sediments. Lesser acceleration may occur from earthquakes originating on the Garlock and San Andreas faults. S~e illustrations. ~,. Trenching. Two 700 foot. trenches were dug to locate surface faulting. None was found. Accompanying are detailed pro- files of the trenches. . -~ ..... The trenches were in lower Kern River Series. The lithology included very firm to soft sands, firm claystone siltstone and conglomerates of various mixtures. The~'information provided here was developed from standard published sources.. However, the user is cautioned that packaged information may supplement, but cannot replace,' the assistance of a technically qualified expert at the .~ scene of the incident If such an expert is not available, call the ~ Northridge Tox-Center at (800) 227-6476 in the USA or (800) 682-9000 in CA,j CHEMTREC, or your nearest poison control center for assistance._~ Sulfuric Acid (EPA) - READ FIRST (NTC) - <1> FIRE/EXPLosION HAZARD Non-combustible and non-explosive oily liquid. May BLEVE. Forms highly toxic and irritant fire products and aerosols. Suppress fires with CO2, dry chemical or water flooding. Caution: reacts with water. <2> HEALTH HAZARD/PROTECTIVE Highly irritates skin, eyes, nose & airway. Avoid vapor inhalation, skin or eye contact, ingestion. Not a poison, carcinogen, teratogen or mutagen. Use EPA'level A protection: SCBA, turnouts, Viton suit, goggles, gloves. <3> MEDICAL AID Wash with soap & water. Double-bag or launder contaminated clothing. Watch for difficulty breathing, chemical pneumonia, laryngitis, pulmonary edema & wheezing. If ingested, don't empty the stomach. May need oxygen & IV fluids. <4> CHEMICAL HAZARDS Does not react with air. May react violently with water, trash, reducing agents, combustibles, organic nitrates, alkalis, soda-ash extinguishers & active metals. Does not Polymerize. Highly corrosive. Strong oxidizer.. - COMPARATIVE HAZARD RATINGS (NTC) - Explosion None Fire . None High Sulfuric Acid (EPA) OVERVIEW -GENERAL OVERVIEW (NTC) - Colorless to dark brown oily inorganic liquid. Very irritating to skin, eyes, nose, throat & lungs. Not a carcinogen, mutagen, teratogen or poison. Odorless. Significant hazards due to oxidizing effect, corrosiveness and irritant action. Reacts violently with water and many other substances. 'Corrodes most metals..May create significant environmental problems due to surface water pollution, adverse~pH effects. Runoff may be a major problem a~nd should be contrQ1Lgd. Use maximum cautio~ for skin and lungs. Exposure ma~y cause burns and chemical pneumonia. Suppress fires using CO2, dry chem- ical or flooding. Fire and decompositionproducts are toxic and irritant. Sinks, mixes and reacts violently when added to water. Vapor not flammable but is dangerous and heavier than air, spreads downwind. AccUmulates in closed spaces and low spots. Placarded as 1830. Used for fertilizers, ex- plosives, fibers, dyes, drugs, chemicals & batteries. - INDUSTRIAL HYGIENE GUIDELINES (NTC) - storage: store in a cool, well-ventilated area. Allow no moisture in area. Keep away from incompatible materials. Reacts with many chemicals. PerSonnel protection: no eating, drinking or smoking in area. Use special clothing. Change and'shower immediately when contaminated. Do not breathe vapor. Watch for vapor accumulation in closed spaces and low-lying areas.- · ~ ' 'Sulfuric Acid (EPA) FIRE / EXPLOSION - FIRE ! EXPLOSION HAZARD POTENTIAL (DOT)'- Some of these materials may burn, but none of them ignite readily. .May ignite other combustible materials (wood, paper, oil, etc.). Violent reaction with water. Flammable/poisonous gases may accumulate in tanks and hopper cars. Runoff to sewer may create fire or explosion hazard. - FIRE / EXPLOSION HAZARD COMMENTS (NTC) - Flash Point Flammability Limits Auto-Ignition' NF.°F NF.°C NF.%(Lo) NF.%(Hi) NF.°F NF.°C Not flammable or combustible. Won't burn, but forms hazardous aerosols. Does not polymerize, but may BLEVE. Smoke or plume from a fire is a moderate high hazard. Wind will direct & precipitation will strip toxins from vapor plume or smoke cloud. - FIRE EMERGENCY ACTIONS (DOT) - Small fires: Dry chemical, CO2 or Halon. . Large fires: Flood fire area with water from a distance. * Do not get'water inside container. Do not get solid stream of water on spilled material. Move container from fire area if you can do it without risk. Cool containers that are exposed to flames with water from the side until well after the fire is out. Stay away from ends of tanks. - EMERGENCY SCENE MANAGEMENT (NTC) - Clear immediate area and downwind for a small spill, but evacuate a wider area if a large container is threatened by fire. Sulfuric Acid (EPA) HEALTH / PROTECTION - HEALTH HAZARD POTENTIAL (DOT) - poisonous if.inhaled or swallowed. Contact causes severe burns to skin and eyes. Runoff from fire control or dilution water may cause pollution. - MAJOR HEALTH EFFECTS (NTC) - -- EXPOSURE LIMITS TLV/STEL UNKNOWN IDLH 80 mg/m3 TLV/TWA 1 mg/m3 ~ -- MAJOR SYMPTOMS / SIGNS OF OVEREXPOSURE Inhalation: irritates nose, throat & upper airway. Erodes teeth. Sore mouth, sneezing, coughing, difficult breathing, laryngeal and tracheobronchial inflamation, acute chemical bronchitis, pneumonia & death. Skin contact: irritation, severe and painful burns, also vascular collapse~ Eye contact: irritation, severe burns & permanent eye injury. Ingestion: erodes teeth, severe burns of mouth & throat, perforation of esophagus or stomach, vomiting of blood & eroded tissue, then death. Central nervous system effects: none. - BASIC EMERGENCY ACTIONS (DOT) - Keep unnecessary people away. Isolate hazard area and deny entry. Stay upwind. Keep out of low areas. Ventilate closed spaces before entering. Wear self-contained (positive'pressure) breathing apparatus (SCBA) and chemical protective clothing specifically recommended by shipper or producer. Such clothing may not provide thermal protection. Evacuate the leak or spill area immediately for at ]east 50 feet in all directions. If the name of this material is on the DOT Guide Table of ~vacuati~n Distances, call for help to perform the recommended evacuation. If water pollution occurs, notify the appropriate authorities. - PROTECTION OF RESPONSE PERSONNEL (NTC) - Recommend EPA level A or equiv. Respiratory: SCBA and encapsulated suit. Eyes: goggles for vapor protection, face shield for. splash protection or encapsulated suit. Skin and extremities: impermeable gloves, boots, clothes, apron, turnouts or encapsulated suit. Chemically resistant materials reco- mmended: preferably Viton and nitrile-butadiene. Can also use PVC, Neoprene, butyl, nitrile rubber, chlorinated polyethylene, styrene-butadiene. Sulfuric Acid (EPA) MEDICAL AID - DECONTAMINATION GUIDELINES (NTC) - Personnel: shower with soap and water. Check for burns. 'Clothing: remove and launder, or double-bag. Equipment: hose off and wipe down using detergent or bicarbonate of soda. Run-off water: may be treated & neutralized with soda ash or lime. - BASIC FIRST AID (DOT) - Move victim to fresh air and call emergency medical care. If not breathing, give artificial respiration. If breathing is difficult, give. oxygen. Remove and isolate contaminated clothing and shoes at the site. Speed in removing material from skin is of extreme importance. In case of contact with material, immediately flush skin or eyes with running water for at least 15 minutes. Keep victim quiet and maintain normal body temperature. - MEDICAL TREATMENT OF VICTIMS (NTC) - Inhalation: move to safety & fresh air. Intubate and resuscitate as needed, including CPR. Provide oxygen, if needed. Monitor breath sounds for chemi- cal pneumonia, start IV TKO, monitor EKG lead II, obtain baseline arterial blood gases. Seek immediate specialty care. Skin contact: check for chemical burns and treat as indicated. Eye contact: irrigate eyes with normal saline or tap water. Do not apply protective eye ointment, patch eyes as needed. Seek immediate specialty care. Ingestion: if conscious, give clear liquids, but do not induce emesis. If unconscious, intubate to protect airway, but no gastric lavage. May perforate esophagus. Seek immediate specialty care. medical surveillance is indicated for possible esophageal strictures. - ABSORPTION / DISTRIBUTION / METABOLISM (NTC) - Absorption: through lungs, mucous membranes, skin, eyes & GI tract. Distribution: to body water stores. Unchanged material: is not excreted. Metabolic conversion forms neutral, sul- fate ion. Metabolized material: neutral sulfate ion is excreted via urine. None re- mains in the body. / Sulfuric Acid (EPA) CHEMICAL REACTIONS - CHEMICAL INTERACTIONS (NTC) - -- WITH WATER Reacts violently with water and releases excess heat in the process. Spatters & boils during reaction with water. Sinks, completely mixes and is extremely soluble in water. Reacts with alkaline solutions. -- WITH OTHER MATERIALS Highly corrosive acid which generates hydrogen gas on contact with metals. Reacts with organic materials and compounds, carbides, chlorates,fulminates, nitrates, picrates, most metals, sodium'carbonate, potassium permanganate, phosphorus, saltpeter, lithium silicide, mercuric nitride, nitrotoluene, acetone cyanohydrin, acetone,' nitric acid and other chemicals. - SPECIAL CHEMICAL HAZARDS (NTC) - Highly corrosive and a strong oxidizer. Will not polYmerize. May form hazardous decomposition products.and hazardous fire products, including toxic aerosols of sulfuric acid & sulfur oxide vapor. Sulfuric Acid (EPA) ENVIRONMENT - ENVIRONMENTAL HAZARDS (NTC) - -- IMMEDIATE ENVIRONMENTAL EFFECTS Effects on air: air pollution limited to local & downwind areas, but rapidly .disperses. Effects on water: potentially severe surface water contamination but is not persistent due to rapid degradation. Effects on soil: potentially severe soil contamination, leading to surface water pollution. Has transient effects only. Not a major hazard to soil. - LONG-TERM ENVIRONMENTAL EFFECTS Local, possibly severe effects in immediate spill area, Long-term effects are minimal due to rapid degradation. Won't bioconcentrate in the food chain. Won't increase chemical or biologic oxygen demand. - SPILL / LEAK EMERGENCY ACTION (DOT) - Do not touch spilled material. Stop leak if you can do it without risk. Do not get water inside container. Use water spray to reduce vapor.'Do not put water directly on leak or spill. Keep combustibles (wood, paper, oil, etc.) away from spilled material. . Spills: Dike for later disposal. Do not apply water unless directed to do so. Cleanup only under supervision of an expert. - EMERGENCY SPILL MANAGEMENT (NTC) - Air releases: monitor situation and evacuate immediate area, allow wind to disperse. Use hose spray to divert or remove toxic material. Water releases: isolate and treat in place with lime or soda ash. Soil Releases: spread lime or soda ash, then fine water spray. - SPILL TREATMENT / DISPOSAL (NTC) - Treat and neutralize with expert assistance, using lime or soda ash. Hazard- ous waste landfill disposal of the untreated material is not recommended. Aldrich chemical catalog advises adding acid to dry soda ash cautiously. May dilute with~water and put down the drain, if a small quantity only. Never add water to acid. Always add acid to water slowly and with constant stirring, to avoid overheating and steam explosions. ~'~'-~ Sulfuric Acid (EPA) IDENTIFICATION - IDENTIFYING NUMBERS / REFERENCES (NTC) - Sulfuric Acid (EPA). Battery Acid. DOT NAME: SULFURIC ACID, 51%-95% PURE DOT ID: 1830 DOT CLASS: CORROSIVE MATERIAL GUIDE: 39 SYS ID: 1076 CAS #: 7664939 STCC: 49-300-40 SAX/6#: 2487/2 UN/NA #: ·1831 RTECS/NIOSH: WS:5600000 MERCK/10 #: 8854 - PHYSICAL ID (NTC) - -- PROPERTIES Normally a liquid & handled as a liquid. Colorless to dark brown. Odorless. Viscosity similar to medium oil. Melting pt. 37F [3C] for 98% acid. Boiling pt. 644F [340C] at 1 atm for 98% acid. Specific Gravity 1.84 at 68F [20C]. Molecular wt. 98.'08. Low vapor pressure. Vapor density 7.3,heavier than air. Extremely corrosive and decomposition products are corrosive. Stable & un- likely to react when exposed to light, heat, sound, percussion or air. -- COMPOSITION / IMPURITIES No significant·additives except water. Sulfuric acid 33 to 100% pure Water 0 to 67% - PACKAGING / PLACARDING (NTC) - Normally stored and transported in rail or highway tankers,small containers. Needs special care in handling as is corrosive, oxidizer, reactive, en- vironmental hazard. Placarded: DOT 1830 (sulfuric acid).1831 (oleum); NFPA 3/0/2; Water Reactive. Hazard labeling: Corrosive Material. ACUT~=LY HAZARDOUS MATERIALS REGISTRATION FORM THIS FORM MUST BE COMPLETED BY THE OWNER OR OPERATOR OF EACH BUSINESS IN CALIFORNIA WHICH AT ANY TIME HANDLES ANY ACUTELY HAZARDOUS MATERIAL IN QU ~ANTITIES GREATER THAN 500 POUNDS, 55 GALLONS OR 200 CUBIC FEET OF GAS AT STP. · TI-~S FORM SHALL BE COMPLETED AND SUBMITTED TO YOUR LOCAL ADMI~STERING AGENCY. (§25533 & 25536 Health & Safety Code) ,. Note instructions on reverse 'JVOv ~ 1988 Business Site Address ~ ~::~"-- C , ~-I ~___T' .~f_.~.. - ..... Business Mailing Address (if different) Business Phone ~t'~',~_~"~ ~3, 4::~ I Business Plan Submission Date2 ACUTELY HAZARDOUS MATERIALS HANDLED4 -USE ADDITIONAL PAGES IF NECESSARY- .,. ..:~ CHFMICA! NAMF QUANTI~ , /~ ~ zz,5 '.~ GENERAL DESCRIPTION OF PROCESSES AND PRINCIPAL EQUIPMENTS: PRINTED NAME~/~y ~~ DATE Cal~omia ~i~ of Eme~e~ ~w~es FORM HM 3~ (1-15-88) INSTRUCTIONS: Superscripts: 1. Quantifies for RMPP compliance are "equal to or greater than" the minimum criteria and apply to chemicals handled "at any one time". 2. Businesses handling reportable quantifies of Acutely I-laTardous. Matefials that have not submitted a business plan. , MUST contaCt local Administering Agencies. The business plan submis~. _'on.da_tD, wLll assure the Administering Agency that a business plan has been submitted and is on f'fle. This will also immediately identify businesses that have not submitted business plans. 3. "Pmce~ Designation" is provided as a reporting option (with the approval of the Administering Agency) for facilities that can most easily report by process. Thus, facility RMPP regiswafion data could be submitted in a similar format to a business plan that is divided by process. "By process" data can initiate an emergency response to a process incident rather than a general emergency response to a major facility. Process designation ........ ..can_simPlify inspec_tion_s ~for mai0_ ~ facilities and improve future emergency_ . _mspon. se._ 4. Refer to the EPA list of Extremely Hazardous Substances from the Federal Register (Volume 52, No. 77, p. 13397 eL sea_,, April 22, 1987). Each chemical has a threshold planning quantity. This list may be changed by EPA on an annual basis. Updates of this list may be available early in 1988. To cixnply with this element, you may attach a copy of the inventory submitted to your Administering Agency from your business plan and highlight all Acutely H~,ardous Materials. It is recommended that facilities list all extremely imu,ardous chemicals handled in quantities ~..', ~ equa,l, ,to or in,excess of 1) 500 pounds, and 2) any EPA threshold planning quantity less than 500 pounds.' 5. Do not include Tra~ Secret information in these descriptions. General:" For emergency response purposes, it would be desirable to describe the following to the Administering Agency: 1. Batch Process: a. What raw materials? b. What operating pressure range? c. What operating temlawamm range? d. Batch capacity rating? e. Product characta'istics? (e.g., chemical state, flammability, toxicity, etc.) .- '. f., · Critical process points and charactea'istics? ~ .......... ' --2. Continuous- ,~ess: (similar-;.nfo.-mafion~-as~above:) ............. NOTE: .... " ~"~ '"Pursuant'to §~i5534, the Administering Agency' may require the submission of a Risk Management Prevention Program ~ (RMPP), if the Administering Agen. cy de .termines, that the:handler's operation may present an acutely h~7-~rdous materials // accident risk. The handler shall prepare the RMPP in accordance with subdivision (c) [of §25534]. The RMPP shall be / . prepared within 12.months following.the request made by the Administering Agency pursuant to .this section." ,~, (§ 25534. (a) Heatth:and'-Safety Code) " ' ' " ' ' ' " An amendment' to the RMPP must be' Submiued to the Administering'Agency within 30 days of: 1. Any additional handling of acutely hazardous materials. 2. Any material or substantial, alterations to-business activitieS.' 3. Change. of address, business ownership, or business name.. (§ 25533 (c) Health & Safety Code) · EVERY BUSINESS REQUIRED TO SUBMIT ANRMPP SHALL .IMPI~EMENT THE APPROVED RMPP. California Office of Emergency Services FORM HM 3777 (1-15-88) "WE CARE" FIRE DEPARTMENT 2101 H STREET D. S. NEEDHAM BAKERSFILED, 93301 326-3911 FIRE CHIEF OCTOBER 19, 1988 PEPSI COLA BOTTLING CO. 215 EAST 21ST STREET' BAKERSFIELD, CA 93305 DEAR MR. JAMES LINDSEY:. THE 'ENCLOSED "ACUTELY HAZARDOUS MATERIALS REGISTRATION FORM" MUST BE COMPLETED BY ANY BUSINESS, HANDLING ABOVE THE MINIMUM REPORTING QUANTITY OF ANY MATERIAL ON THE EPA LIST OF EXTREMELY HAZARDOUS SUBSTANCES. (FED. REGISTER VOL. 52, NO. 77, P. 13397). YOUR COMPANY HAS REPORTED HANDLING THE FOLLOWING ACUTELY HAZARDOUS MATERIALS: ANHYDROUS AMMONIA PLEASE RETURN THE COMPLETED ACUTELY HAZARDOUS MATERIALS REGISTRATION FORM TO:' HAZARDOUS MATERIALS DIVISION 2130 G STREET BAKERSFIELD, CA 93301 IF YOU HAVE ANY QUESTIONS REGARDING THIS FORM PLEASE CALL RALPH HUEY AT 326-3979. SINCERELY YOURS, HAZARDOUS MATERIALS COORDINATOR REH/ed ENCLOSURE SULFURETrED HYDROGEN 1108 sulfuretted hydrogen. See hydrogen sulfide. sulfur hexafluoride. CAS: 2551-62-4. SF6. Properties: Colorless gas, fp --64C (sublimes), d (gas) 6.5 g/L, d (liquid) 1.67, specific volume 2.5 cu fi/lb (21.1C), slightly soluble in water, soluble in alcohol and ether, odorless. Noncom- bustible. Hazard: TLV: 1000 ppm in air. Use:' Dielectric (gaseous insulator for electrical equipment and radar wave guides). sulfuric acid. (hydrogen 'sulfate; battery acid; electrolyte acid). CAS: 7664-93-9. HaSO4. By far the most widely used indus- trial chemical, its production was 79.23 billion pounds· in 1985. Highest-volume chemical pro- duced in US (1985). Properties: Strongly corrosive, dense, oily liquid; colorless to dark bi'own depending on purity; miscible with water. Very reactive, dissolves most metals; Concentrated acid oxidizes, dehydrates, or sulfonates most organic compounds, often causes charring; d of pure material 1.84; mp 10.4C; bp varies over range 315-338C due to loss of sulfur trioxide during heating to 300C or higher. Note: Use great caution in mixing with water due to heat evolution that causes explosive spattering. Always 'add the acid to water, never the reverse. Derivation: From sulfur, pyrite (FeS:), hydrogen sulfide, or sulfur-containing smelter gases by the contact process (vanadium pentoxide catalyst). The first step is combustion of elemental sulfur or roasting of iron pyrites to yield sulfur dioxide. Then follows the critical reaction--catalytic oxi- dation of sulfur dioxide to sulfur trioxide (so + 425 C in a foUr-stage converter at 425--450C with evolu- tion of heat. After cooling to 160C, the sulfur trioxide is absorbed in a circulating stream of 98-99% sulfuric acid, where it unites with the small excess of water in the acid to form more sulfuric acid. (SO~ + H~O 260°C-~H~SO~) Sulfuric acid can also be made by the "Cat-Ox" '- process and from gypsum ·(calcium 'sulfate). Grade: Commercial 60 degrees B6: (d 1.71, 77.7% sulfuric acid); 66 degrees B6 (d 1.84, 93.2% sul- furic acid); 98% (d 1.84); 99% (d 1.84). 100% Use: Fertilizers, chemicals, dyes and etchant, alkylation catalyst, electroplating baths,. iron and steel, rayon and f'tim, industrial explo-. sives, lab reagent, nonferrous metallurgy. See also sulfuric acid, fuming. sulfuric acid, fuming. (oleum). ~ CAS: 8014-95-7. xHaSO4-ySOa. A tion of sulfur trioxide in sulfuric acid. Properties: Heavy, oily liquid; colorless to brown depending on purity; fumes moist air. Extremely hygroscopic. Derivation: Sulfur trioxide produced by tact process is absorbed in concentrated acid. Grade: Commercial (10-70% free SOa depending on supplier), CP. Hazard: Reacts violently with water. Strong irri- tant to tissue. Use: Sulfating and suifonating agent, dehydrating agent in nitrations, dyes, explosives, lab reagent. sulfuric anhydride. See sulfur trioxide. . sulfuric chloride. See sulfuryl elfloride. sulfuric oxychloride. See sulfuryl chloride. sulfur monohromide. See sulfur bromide. sulfur monochloride. See sulfur chloride. sulfurous acid. CAS: 7782-99-2. A solution of sulfur dioxide in water. The formula H:SOa is used, but the acid is known only through its salts. Properties: Colorless liquid, suffocating sulfur odor, d 1.03, unstable, soluble in water. Derivation: Absorption of sulfur dioxide in water. Grade: Technical, CP. Hazard: Toxic by ingestion and inhalation, strong irritant to tissue. Use: Organic synthesis, bleaching straw and tex- tiles, etc.; paper manufacture, wine.manufacture, brewing, metallurgy, ore flotation, medicine (an- tiseptic), reagent in analytical chemistry, sulfites, as preservative for fruits, nuts, foods, wines, dis- infecting ships. sulfur oxychloride. See thionyl chloride. s'uffur subchloride. See sulfur chloride. sulfur tetrafluoride. CAS: 7783-60-0. SF4. Properties: A gas, fp --124C, bp --40C, decom- ..... in water. Nnncomhustible. 1109 Use: Fluorinating agent for making water and oil repellents and lubricity improvers. sulfur trioxide. (sulfuric anhydride). CAS: 7449-11-9. SOa, (SOah. Properties: Exists .in three solid modifications; ct mp 62C, fl mp 32.5C, 7 mp 16.8C. The ct form appears to be the stable form but the solid transi- tions are commonly slow; a given sample may be a mixture of the various forms and its melting point not' constant. The solid sublimes easily. Derivation: Passing a mixture of SO: and oxygen over a heated catalyst such as platinum or vana- ~i dium pentoxide. ...~ . See sulfuric acid. Hazard: Oxidizing agent, fire risk in contact with organic materials, an explosive increase in vapor pressure occurs when the ct form melts. The anhydride combines with water, forming sulfuric ' acid and evolving heat. Highly toxic, strong irri- tant to tissue. use: Suifonation of organic compounds, especially nonionic detergents, solar energy Collectors. It is usually generated in the plant where it is to be used. sulfuryi chloride. (chlorosulfuric acid; sulfonyl chloride; sulfuric chloride; sulfuric oxychloride). CAS: 7791-25-5. SO:CIa. Properties: Colorless liquid, pungent odor, rapidly decomposed by alkalies and by hot water, soluble in glacial acetic acid, d 1.667 at 20C, bp 69.2C; fp --54C, yap d 4.6. Derivation: (a) By heating chlorosulfonic acid in the presence of catalysts. (b) From sulfur dioxide and chlorine, in the presence of either activated carbon or camphor. Grade: Technical. Hazard: Strong irritant to tissue. 'Use: Organic synthesis (chlorinating agent, dehy- drating agent, acylating agent) pharmaceuticals, dyestuffs, rubber-base plastics, rayon, solvent, · catalyst. Sulfuryl fluoride. CAS: 2699-79-8. SO:F:. Properties: Colorless gas, fp--136.7C, bp --55.4C, slightly soluble in cold water and most organic solvents. Noncombustible. Hazard: Toxic by inhalation. TLV: 5 ppm in air. Use: Insecticide, fumigant. sulphenone. (p-chlorophenyl phenyl sulfone). - CAS: 80-30-2. 'Properties: White solid with mp 98C; insoluble -- in water; soluble in hexane, xylene, carbon tetra- chloride, and acetone. SUNFLOWER OIL ness to washing, etc.; can be used on leather and paper. sultam acid. (1,8-naphthosultam-2,4-disulfonic acid). C~oH~(SOsI-DaNHSO:. Properties: White solid, soluble in water" slightly soluble in alcohol. -, Derivation: Sulfonation of 1-naphthylamine-8-sul- fonic acid or l-naphthylamine4,8-disulfonic '. acid. .- .... . . ".-: Use: Intermediate for Chicago acid. ' sulvanite. (ethyl sulfuryl chloride). Properties: Colorless liquid with bp 135C. ' Use: Poison gas. Sumner, James B. (1887-1955) An American bio- chemist who won the Nobel prize in chemistry in 1946 along with Northrop and Stanley. His work was mainly concerned with enzymes, and he was the first in the field to isolate and crystal- lize an enzyme and determined it was a protein. He inspired followers to continue research in vi- rus and enzyme study. His education was at Har- vard and he taught for many years at Cornell. samp. A chamber or large container into which waste liquids from processing or mechanical op- erations are allowed to collect and from which they are removed by a pump .... "' "Sumstar' 190:::. TM for a polymeric dialde- hyde; a fine, nonvolatile, virtually odorless pow- der, produced by highly specific periodate oxida- tion of the anhydroglucose units of starch; bulk d 40-42 lb/cu ft. Use: Film-forming agents, adhesives, leather, and resins. "Sundex' Oilsl6L TM for a series of aromatic process and extender oils. Recommended for rubber processing where color is not a problem. Use: Plastieizers, softeners sunflower cake. The presscake resulting from hy- draulic press expression of sunflower seeds. Typi- cal analysis: proteins 21.0%, fats 8.5%, fiber 48.9%, water 10.2%, ash 11.4%. Use: Cattle food, fertilizer ingredient. sunflower meal. The mealy form assumed by sun- flower seeds after crushing and heating. If the oil cake is ground the product again is in this mealy form. It contains 55-60% protein. Use: Animal feed, fertilizers. bert, in Comprehensive Inorganic Chemistry vol. t- Bai- solvent: Waddington, Non-aqueous Solven lar, Jr. et al., Eds. (Pergamon, Oxford, 1973) pp-n'~r95-933. Waddington, Ed. (Academic Press, New Orthorhombic, cycloocta- or a-sulfur, amber-colored crystals; the stable form at ordinary temperature, d 2.06; when heated to 94.5' becomes opaque owing to the forma- tion Of monociinic sulfur. Moa.clinic, cyeloocta- or /~-sulfur,' light-yellow, opaque, brittle, needle-like crystals; stable between 94.5-120°. Passes slowly into the rhombic form on standing, d 1.96; mp 115.21': West, J..4m. Chem. Soc. 81, 29 (1959). bp about 444.6'. A second moa,clinic form, ~,-sulfur or mother-of- pearl sulfur is also known; mp 106.8'. ' Sulfur is insol in water; sparingly sol in alcohol, in ether; sol in carbon disulfide (one gram/2 ml); sol in benzene (about 2.4'70 at 30', much more at higher temps.), in toluene. Liquid ammonia (anhydr) dissolves 38.5% S at --78°; ace- tone dissolves 2.65% at 25'; methylene iodide dissolves 9.1% at 10'; chloroform dissolves about 1.5% at 18'. For other solvents seeTuller, op. cit. Ignites in air above 261', in oxy- gen below 260', burning to the dioxide; combines readily with hydrogen; combines in the cold with fluorine, chlorine, and bromine; combines with carbon at high temperatures; reacts with silicon, phosphorus, arsenic, antimony and bis- muth at their .melting points; combines with nearly all met- als; with lithium, sodium, potassium, copper, mercury and silver in the cold on contact with the solid; with magnesium, zinc and cadmium very slightly in the cold, more readily on heating; with other metals at high temperatures. Does not react with iodine, nitrogen, tellurium, gold, platinum and iridium. Polymeric sulfur, Crystex. Amorphous form; mol wt ap- prox 200,000. Metastable, gradually reverts to the a-roi're. Insol in solvents used for ,rrb,th.robie form. Reviews: Meyer, loc. ci~ (1964); A. V. Tobolsky, W. J. MaeKnight, Polymen'c Sulfur and Related Polymers (Interscience, New York, 1965) pp 87-97. Note: See also Sulfur, Pharmaceutical. ' usE: In mfg sulfuric acid, carbon disulfide, sulfites, insec- ticides, plastics, enamels, metal-glass cements; in vulcanizing rubber; in syntheses of dyes; in making gunpowder, matches; for bleaching wood pulp, straw, wool, silk, felt, linen. Cau- tion: May cause irritation of skin, mucous membranes. 8850. Sulfur Chloride. Disulfur dichloride; sulfur mono- Chloride; sulfur subchloride. C12S2; mol wt 135.03. CI 52.52%, S 47.48%. S2C12. Prepared by passing chlorine into molten sulfur, can be purified by fractional distillation: Feh6r in Handbook of Preparative Inorganic Chemistry vol. 1, G. Brauer, Ed. (Academic Press, New York, 2nd ed., 1963) pp 371-372. Hydrolysis: H. L. Olin, J. dm. Chem. Soc. 48, 167 (1926). Non-flammable, light amber to yellowish red, fuming, oily liquid. Penetrating odor. Vapors are corrosive and irritate eyes, nose, and throat, cause tears and affect breathing, dls.s 1.6885. nD~ 1.670. mp --77'. bp~ 138'; bp~00 72.0°; bp~0 19.1°. Dielectric constant 4.9 at 22'. Dipole moment 1.60. Sol in alcohol, benzene, ether, carbon disulfide, carbon tetra- chloride, oils. Readily dissolves sulfur (up to 67% at room tamp). Dee by water yielding sulfur, hydrogen chloride, sul- fur dioxide, hydrogen sulfide, sulfite, thiosulfate. In acid solns pentathionic and other polythionie acids are formed. Keep tightly closed and out of contact with water. USE: Intermediate and chlorinating agent in the manuf of organic chemicals, sulfur dyes, insecticides, synthetic rub- bers; in cold vulcanization of rubber; as polymerization cata- lyst for vegetable oils; for hardening soft woods. 8851. Sulfur Dioxide. Sulfurous anhydride; sulfurous oxide. O~S; mol wt 64.07. O 49.95%, S 50.05%. SOa. Colorless, nonflammable gas; strong suffocating odor. Condenses at --I(Y' and ordinary pressure to a colorless liq- uid. d (liq) 1.5. Solidif --72'. bp --10'. Mixed with oxy- gen and passed over red-hot Pt, it is converted into SOs. With water forms sulfurous acid (H~SO~). Bleaches vegeta- ble colors. Soly: in water 17.7% at 0°, 11.9% at 15°, 8.5% at 25°, 6.4% at 35°; in alcohol 22%; in methanol 32'70; also sol in chloroform or ether. It is supplied compressed in cylinders. UsE: Preserving fruits, vegetables, etc.; disinfectant in breweries and food factories; bleaching textile fibers, straw, T~ {2. 1965) pp 253-284. Caution: Intensely irritating to eyes, respiratory tract. 8852. Sulfuretin. 2-[(3,4-Dihydroxyphenyl)methylene]. 6. hydroxy-3(2H)-benzofuranone; 2-(3,4-dihydroxyben::yli. dene)-6-hydroxy. 3(2H).benzofuranone; Y,4',6-trihydroxy. aurone 3' 4',6-trihydroxybenzalcoumaranone. C~sH__O · mol wt 270.23. C 66.67%, H 3.73%, O 29.60%. Flavonoid pigment responsible for the yellow color of certain species of Compositae. Is,in from Cosmos sulphureus Cav., Compositae:' Shimokoriyama, Hart,ri, J. Am. Chem. Soc 75, 1900 (1953); from Dahlia variabilis Desf., Compositae: N0rdstriJm, Swain, Arch. Bi.chem. Biophyx 60, 329 (1956). Prepn by condensa. tion of 6-hydroxy-3-coumaranone and protocateehuic alco- hol: Nordstr/Jm, Swain, ibid. Prepn and structure studies: Geissman, Jurd, J. Am. Chem. Soc 76, 4475 (1954); Farkaa et aL, Ber. 92, 2847 (1959). Structure: Shimokoriyama, Geissman, J. Org. Chem. 25, 1956 (1960). tn lthe acid should be added to ~:luent Keep tightly dilut' g, ' closed- ~andle with caution, avoidin~ttact with the skin as itt~roduces severe burn~ LDs0 orally in rats: 2.14 g/kg, H. ~:'~mvt~ et al. Am. Ind. Hyg. Assoc. J. 30, 470 (1969). ~'- '"~ ' ' i Inhalation of .~ Caution: Corroswe to all body tssues. ~cd v~por may cause serious lung damage. Contact with ~v~s ma~ result in total loss of vision; skin contact may ~ ~oduce ~severe necrosis. Ingestion may cause severe .injury , r-~ aeat~ Fr,nnuent skin contact with dil soln has caused dermatitis, cf. Clinical Toxicolog. v of Commercial Products, R. E, Gosselin et al., Eds. (Williams & Wilkins, Baltimore, 1 ~:~: 4th ed., ~976) section III, pp 2-6. ! '~ USE: in manuf of fertilizers, explosives, dyestuffs, other .[~!~'acids, p~rehment paper, glue, purification of petroleum, · ~l-~ ,,ickling bf metal. '! i:'~:~'11iZgn~ CAT: Dil acid in gastric hypoacidity. Conod ac~d ~':':lormerlytas a topical caustic. :~l(~ '8855,~ Sulfuric Acid, Fuming, H2SOs with free SOj, des-. ~l~'!~'i~nated ih commerce as oleum. There are available grades of :'-'l~ ~ning s~lfunc acid, olenm, contg up to about 80% free SO~. or slightly colored, viscous liq, emitting choking _~ of, sulfur trioxide. Extremely corrosive. Handle with ~'!i ~' great ca~r. Keep tightly closed in glass-stoppered bottles. -i~'~i: 8~6. sUlfUr Iodide. Iodosulfane. Approx SI. Obtained ~(~"~'~0 :~l~ 'by fusing together 4 parts iodine with 1 part sulfur. It prob- .~l'L_~ ably eoff.tains free iodine as well as free sulfur. ~li~c GrayiSh-black masses of metallic luster and iodine odor. Orange crystals from dil aic, mp 280-285° (Shimokori- .~ lnsol inlwater; sol in carbon disulfide, alcohol, ether, in yama), mp 315' (dec) (NordstriSm), mp 302-304' (Farkas).~!! ..... ~ sbout 51} parts glycerol. KI soln dissolves a portion of the uv max: 398 nm. ~ :E!!~ iodine l~ving free sulfur. Keep well'closed- Triacetate, CnH~sOs, pale yellow needles from methanol, ((~ XltBl~ CAT: Dermatologic. mp 191-194° (Shimokoriyama), mp 167-168' (NordstrSm). ~ .~;~ ~ Tlml~ CnT (YETI: Has been used in chronic eczema, ring- 8853. Sulfur Hexafluoride. FsS; mol wt 146.07. F .~worm, mange. 78.05 , s 21.95%. SF,. Pre, by dir t fi orination aci diozide soln.^ sola of fur or sulfur dioxide: Moissan, Lebeau, Compt. Rend. 130, 865, 984 (1900); eidern, Ann. Chim. Phys. [7] 26, 147 (1902); i~bout 6,% sulfur dioxide in water. Schumb, Inorg. Syn- 3, 119 (1950); Kwasnik in Handbook of ~? Colorless, clear, acid liquid; suffocating odor of sulfur di- Preparative Inorganic Chemistry, Vol. 1, G. Brauer, Ed. ~%0~ide. d~about 1.03. Oradually oxidizes in the air to sulfuric '~ ~;' K',e nearly full tightly closed containers, in a cool (Academic Press, New York, 2nd ed., 1963) pp 169-170.'~'~'~E ep in Reviews: Cady, "Fluorine-Containing Compounds of Sul- ! fur" in Advan. Inorg. Chem. Radiochem. 2, 105-157 ~IERAI' CAT: Antiseptic; dental bleach. Kemmitt, Sharp, Advan. Fluorine Chem. 4, 218-219 (1965). I Colorless, odorless gas. One of the heaviest known I Sul/ur, Pharmaceutical. Three forms of sulfur of density approx 5 times that of air. mp --50.8'. Sublimes at or better are recognized in pharmacy. Precipi- --63.8'. Crit temp 45.6'. d (liq; --50.8') 1.88. Sparingly sol tared sulfur, also known as milk of sulfur, made by boiling in water, somewhat more in alcohol. At 25' and I atm 0.297 . sulfur w~th lime and pptg the filtered soln with hydrochloric mi SF~ dissolves in 1.0 ml of transformer oil. Thermody-ii' acid. Sublimed sulfur, also known as flowers of sulfur. namically unstable but kinetically stable gas. This by treating sublimed sulfur with am- explained by symmetrical, octahedral structure of the purities, particularly arsenic (the U.S.A. cule. Inert to nucleophilic attack. Does not attack practically no arsenic) and to remove traces No fluorine exchange with HF. Stable to silent discharge. Unchanged at 500'. and washed sulfur are in the form of a fine, yel- with only a faint odor and taste. Both are u$£: In electrical circuit interrupters. In usually incompletely sol in carbon disulfide. high frequency, piping, sulfur is in the form of a very fine, pale yellow, 8854. Sulfuric Acid. Oil of vitriol. H:O~S; mol odorless and tasteless. It H 2.06%, O 65.25%, S 32.69%. H~SO~. Prepd by the more quickly and usually more completely in tact Process according to the reactions 2SO~ + O~ ~ than the other forms. Soly in anhydr lan.- and SOz + H20 ~ H:SO~; by the Chamber Process 4~: 0.38%; in olive oil at 15': 2.2%, at 30°: 4.1%, at ing to the reactions 2NO + Oa ~ 2NO~, and NO~ + 20.0%. + Ha, ~ HzSO¢ + NO. Sulfuric acid CAT: Precipitated and sublimed sulfur as scabi- rains 93-98% HaSO~; the remainder is water. W. W'. Duecker, J. R. West, The Manufacture of (VET): Externally: antiseptic and parasiticidal; AcM(Reinhold, New York, 1959) 515 pp. Review of ointments and dips, often with lime. Internally: Pearce, "Sulphuric Acid: Physico-Chemieal . beexl used as a laxative, coccidiostat. Manufacture" in Inorganic Sulphur Chemistry, O. Ed. (Elsevier, New York, 1968) pp 535-561; Faith, KeyeS Sulfur Tetrafluoride. F~S; mol wt 108.07. F Clark's Industrial Chemicals, F. A. Lowenheim, .33%, IS 29.67`70. SFa. First prepd from cobalt trifluoride Moran, Eds. (Wiley-lnterscience, New york,4th ed., elemental sulfur: Fischer, Jaenekner, ,4ngew. Chem. 42, pp 795-806. Kwasnik in Handbook of Preparative Inorganic Clear, colorless, odorless, oily:liquid. Very corrosivel vol. 1, G. Brauer, Ed. (Academic Press, New a very great affinity for water, abstracting it from the ed:; 1963) pp 168-169. Best prepared from SCIa also from many organic substances; hence it chars aF suspended in acetonitrile; also from sulfur, chlorine wood, etc. d about 1.84. bp about 290'; at 340° it dec Sodium fluoride: Tullock et al., J. Am. Chem. sulfur trioxide and water. The anhydr acid freeZeS a Arth, Fried, U.S. pat. 3,046,094 (1962 to Merck 98`70 HzSO4 at 43'; 93`70 at --32'; 78% at --38'; Fawcett, Tullock, lnorg. Syn. 7, 119 (1963). Re- -44'; 65% at --64°. Misc with water and alcohol prepn and chemistry: Smith, ,4ngew. Chem. Int. Ed. o~n~ratlc~n nf m-,'h h~at ancLwi~Lnc~ntra, ' VOl. -~75 (1962); Kemmitt, zidvan. Fluorine Chem. 4, 220-222 (1965); Martin, ~ ~. Acad. Sci. 145, 161- 168 (1967). · Colorless gas. Thermostable to 600'. mp --121.0°. bp --38°. d (liq; --78°) 1.95. d (solid; -- 183°) 2.349. Freely sol in benzene. Violent reaction with'water. Dec by coned H~SOs. Attacks glass but not quartz or mercury. Human Toxicity: About as toxic as phosgene. Strong irritant, corrosive. USE: Selective fluorinating agent. 8860. Sulfur Trioxide. Sulfuric anhydride; Sulfan..sS; mol wt 80.07. O 59.95%, S 40.05%. SOs. Exists in 3 modi- fications. Prepd by the contact process, i.e., by the action of oxygen on sulfur dioxide in the presence of catalysts such as platinized asbestos, platinized magnesium sulfate, ferric ox- ide, or vanadium compds. Extensive review and bibliogra- phy: Fairlie, Sulfuric Acid Manufacture, A.C.S. Monograph Series no. 69 (New York, 1936). May be prepd in the labor- at,fy by heating fuming sulfuric acid and collecting the sub- timate in a cooled receiver. If the vapor is condensed above 27', the ;,-form is obtained as a liquid. If the vapor is con- densed below 27' and in the presence of a trace of moisture, a mixture of all~ 3 forms is obtained. The 3 forms can be separated by fractional distillation. The a-form is the stable modification, the B- and -~-forms are metastable. a-Form, asbestos-like needles, mp 62.3'. Vapor pressure at 25' = 73 mm. B-Form, asbestos-like neeedles, mp 32.5'. Vapor pressure a( 25° = 344 mm. -y-Form, ice-like mass, mp 16.8' or liquid, d 1.9224. bp~0 44.8°. Vapor pressure at 25°.= 433 mm. Melted SOs exists in the 'r-form and on solidifying tends to the a-form. The difference in vapor pressures explains the so-called "alpha explosion" .of sulfur trioxide. Heating of high-melting SOs in glass vessels should be avoided to possible shattering of the container. Absolutely dry SOs is not corrosive to metals and shows no acid reaction. On exposure to air, it absorbs moisture rapidly, emitting dense white fumes. Combines with water with explosive violence (heat of dilution 504 eals/g) forming sulfuric acid. Due to this avidity for water, SO~ chars many organic sub- stances. On contact with wood shavings the heat produced by dehydration is sufficient to cause fire. Under the trademark Sulfan, a product is marketed which contains 0.5% of a stabilizer to prevent polymerization to higher melting forms: Sulfan A consists largely of B-SO~ and melts at 30-35°; Sulfan B consists largely of -~-SOs and melts at 17°. Sulfan C contains no stabilizer and will poly- merize to a-SOy USE: Intermediate in sulfuric acid manuf; in sulfonations for formation of addition compds with amines; in the manuf of explosives. Caution: Irritant and corrosive to mucous membranes. May cause coughing, choking and severe dis- comfort in a concn of I ppm. 8861. Suffuryl Chloride. CI~O~S; mol wt 134.98. CI 52.54'70, 0 23.71%, S 23.76%. SO,CIa. Prepd by passing a mixture of dry sulfur dioxide and chlorine through activated charcoal (other catalysts, such as camphor, can be used): Danneel, Angew. Chem. 39, 1553 (1926); Durrans, J. Chem. Ind. 45, 347 (1926); Meyer, Angew. Chem. 44, 41 (1931); Danneel, Hesse, Z. ,4norg. Allgem. Chem. 212, 214 (1933); Allen, Maxson, Inorg. Syn. 1, 114 (1939). Colorless, mobile liquid, very 'pungent odor. Even the vapors are corrosive to human skin and mucous membrane& Turns yellow upon prolonged standing because of slight into SO~ and C1a. d~ 1.6674. d°~ 1.7045. mp --54.1° (also given as --46'). bp 69.3°. n~)° 1.4437. Dipole moment 1.86. Trouton constant 20.7. Slowly dec by water, forming H2SO4 and HCI. With ice-cold water it forms a hydrate, SO~CI~.15HzO, resembling camphor in appearance. Violent reaction on contact with alkalies. Miscible with benzene, toluene, ether, glacial acetic acid, other organic solvents. USE: Chlorinating and sulfonating or chlorosulfonating agent in organic syntheses, e.g., in the manufacture of chlo- rophenol and chlorothymol. Has been used in war gas formulations. 8862. Sulfuryl Fluoride. Vikane. F202S; mol wt 102.07. F 37.23%, O 31.35%, S 31.42%. SO:F.,. Prepd by heating SECTION 2308 Wind Pressure (Continued) UNIFORM BUILDING CODE and constructed to withstand upward pressures equal to one and eno-fourth times those values set forth in Table No. 23-E. The upward pressures shall be assumed to act over the entire roof area. (d) Roofs with Slopes Greater than 30 Degrees. Roofs or sections of roofs with slopes greater than 30 degrees shall be designed and constructed to withstand pressures, acting in- ward' normal to the surface, equal to those specified for the height zone in which the roof is located, and applied to the windward slope only. (e) Anchorage Requirements. Adequate anchorage of the roof to walls and coltunns, and of walls and columns to the foundations to resist overturning, uplift, and sliding, shall be provided 'in all cases. (f) Solid Towers. Chimneys, tanks, and solid towers shall be designed and constructed to withstand the pressures as specified by this Section, multiplied by the factors set forth in Table No. 23~F. (g) Open Frame Towers. Radio towers and other towers of trussed construction shall be designed and constructed to withstand wind pressures specified in this Section, multiplied by the shape factors set forth in Table No. 23-G. Wind pressures shall be applied to the total normal pro- jetted area of all the elements of one face (excluding ladders, conduits, lights, elevators, etc., which shall be accounted for separately by using the indicated factor for these individual members). (h) Miscellaneous Structures. Greenhouses, lath houses and agricultural buildings shall be 'designed for the horizontal wind pressures as set forth in Table No. 23-E, except that, if the height zone is 10 feet or less, two thirds of the first line of listed values may be used. The structures shall be designed to withstand an uplift wind pressure equal to three-fourths of the horizontal pressure. (i) Moment of Stability. The overturning moment calcu- lated from the wind pressure shall in no case exceed two- thirds of the dead 10ad resisting moment. ~ The weight of earth superimposed over footings may be used to calculate the dead load resisting moment. (j) Combined Wind and Live Loads. For the purpose of determining stresses all vertical design loads except the roof live load and crane loads shall be considered as acting simul- taneously with the wind pressure. SECTIONS 2309-2314 1970 EDITION Sec. 2309. The live loads for which each floor or part UveLeads mmercial or industrial building is or has been Posted thereof .of ,a ,co,. --~- .~;,~ed live loads consp!c.uou, sly all nave SUci~ designed sn. · L~_ .... ,~ ,,~ each storv in which they .posted by the,ow~, ,er in ~.n~t_.v~-,~, V~nd it shall'be unlawful to aovly, using duraole .memj. s~S,l~_ ........ nt of the building -- eface SUCh nOTICes. Iii~ r.em..ov, e or d .~,~ ~. u~onin~ the actual ]oad below the shall De responslmu ~u, ~r o allowable limits. - Sec. 2310. Retaining walls shall be designed to resist the Retaining lateral pres ute of the retained material in accordance with Wails ' _ ~gineerin~t practice. Walls retaining drained earth accepted · 'e i ned fo~ pressure equivalent to that exerted by. may be de.s ~g. ~ ~ ....~-~ ~0 ,~ounds per cubic' Foot and a fluid w _gn _g .... t_~ ~ ~e retained earth. Any .suro · . e th e(lua! to mat ~ ~- hawng a d,,p~_ :.: ~aai~i~n to the eauivalent fluid pressure. charge shah ~ - ......... Footing Sec. 2311. See Chapter 29. Design See. 2312. (a) General. Walls and structural Framing Wallsand shall be erected true and plumb in aceordanc~ with· the de- Structural in shall be placed durin~ erection wherever neces- ' Framing sign. Brae] g ~ - ~ ...... ~ich the structure may be sary to talce care ot an ~uu~,~ ~, ' subiected'terior Walls· Interior walls, permanent pa_~titi.on,s; (b) In .... ~':~h exceed 6 Feet in height shal~l and temporary paruuons win,: . . ,.' d to resist all loads to which they are subjected ~,e~e2j~ef~ than a force of five pounds per s~quar,e f.o_~tn?uPJyedr ...... N.._~ .... +1,,~ ,-alls The deflection ot SUCh perpena uta~ ~.u u Cfive foot shall not exceeo a load o pounds per. square. . d 1 19.0 of the of the span for walls'w~thbnttle fimshes an / for walls with flexible finishes. See Table No. 23-1 for span. ........ :~ents where such requirements are earthquake Oeslgn more restrictive. Sec. 2313. Coucrete or masonry walls shall be anchored ~neh0rag~ to all floors and roofs which provide lateral support for the wall or are required to provide stability for the wall. Such ora e shall be capable of resisting the horizontal forces anch.,~ [[ ..... r'l~o,~t,~r or a minimum force of 9.00 po?ds llleo, lU [ill~ ~a~ spec! ~ · ~ ~' ~-'~ .... r is the lar~er. Beqmred an-.. · ear loot ol Wall, w~c~cv~ ~, . p~er !_~n..,~ --asonr,~ walls of hollow units or cavCy.,walls,shall ~t°~ ~rei~'nforcdd grouted structural element ot me wan. Sec. 231~1. (a) General. Every building or structure and [arthq-a~e every portion thereof shall be designed and constructed to R~galaU0ns resist sEresses produced by lateral forces as provided in this Section. Stresses shall be calculated as the effect of a ~orce applied horizontally at each floor or roof level above the foundation. The force shall be assumed to come from any horizontal direction. · ~The provisions of this Section apply to the structure as a' unit and also to all parts thereoL including the sh-uctural 117 SECTION 2314 Earthquake Regulations (Continued) UNIFORM BUILDING CODE frame or walls, floor and roof systems, and other structural featnres. (b) Definitions. The following definitions apply only to the provisions of this 'Section: BOX sYSTEM is a strnctural system without a complete vertical load-carrying space frame. In this system the re- quired lateral forces are resisted by shear walls as hereinafter defined. LATERAL FORCE RESISTING SYSTEM is that part' of the structural system to which: the lateral forces prescribed in Section 2314 (d) 1 are assigned. SHEAR WALL is a ~vall designed to resist lateral forces parallel to the wall. Braced frames subjected prim,-irily to axial stresses shall be.considered as shear walls for the pur- pose of this definition. .SPACE FRAME is a three-dimensional Structural system composed of interconnected members, other than bearing walls, laterally supported so as to function as a complete self- contained unit with or without the. aid of horizontal dia- phragms or floor bracing systems. SPACE FRAME-DUCTILE MOMENT RESISTING is a space frame-moment resisting complying with the require- ments for a ductile moment resisting space frame as given in . Section 2314 (j). SPACE FRAME-MOMENT RESISTING is a vertical load cari'ying space frame in which the members and joints are capable of resisting design lateral forces by bending moments· SPACE FRAME--VERTICAL LOAD-CARRYING is a space frame designed to carry all vertical loads. (c) Symbols and Notations. The following symbols anal notations apply only to the provisions of this Section. C = Numerical coefficient for base shear as specified in Section 2314 (d) 1. ~ NUmerical coefficient as specified in Section 2314 (d) 2 and as set forth in Table No. 23-I. D ~ The dimension of the building in feet iu a direction parallel to the applied forces. : The plan dimension of the vertical lateral force re- sisting system in feet. Fi, Fa, Lateral force applied to level "i," "~," or "x," respec- F~ = tively. F~ ~ Lateral forces on the part.of the structnre and in the direction under consideration. hi, ha, I = K Lev- el i Lev- el n Lev- el x M V [[[l F, = That portion of "V" considered concentrated at the .-~ ~ Z I1~ top of the structure, at the level "n" The remainin,~ III ' !1/ 1970 EDITION portion' of the total base shear "~' shah be distributed over the height of the structure including level "n" according to Formula (14-5). Height in feet above the base to level "i," "n," or "x," respectively. Numerical coefficient for base moment as specified in Section 2314 (h). Numerical coefficient for overturning moment at levei = NUmerical coefficient as set forth in Table No. 23-H. = LeVel of the structure referred to by the subscript "i." That level which is uppermost in the main portion of = the structure: That level which is under design consideration. Overturning moment at the base of the building or structure. The overtUrning moment at level "x." Total nUmber of stories above exterior grade. Fundamental period of vibration of the building or structure in seconds in the direction under considera- tion. Total lateral load or shear at the base. n V = Ft + ~' Fi i= I where i = 1 designates first level above the base· W = Total dead load including partitions using the actual weight of the partitions or the partition loading spec- ified in Section 2302 (b). i=1 · EXCEPTION: "W" shall be equal to the total dead load plus 25 per cent of the floor live load in storage and ware- house occupancies. wi, That portion of "W" which is located at or is assigned = to level "i" or "x" respectively. = The weight of a part or portion of a structure. : Numerical coefficient dependent upon the zone' as determined by Figures No. 1, No. 2 and No: 3 in this 119 SECTION 2314 EaKhquake Regulations (Continued) SECTION 2314 Earthquake Regulations (Centinued UNIFORM BUILDING CODE Chapter. For locations ]n Zone No. I ."Z" shall be equal to one-fourth. For locations in Zone No. 2 "Z" shall be equal to one-half. For locations in Zone No. 3 "Z" shall be equal to one. (d) Minimum Earthquake ForCes for Structures.' 1. Total lateral force and distribution of lateral force. Every structure shall be designed and constructed to withstand minimum total lateral seismic forces assumed to act nonconcUrrently in the direction of each of the main axes of the structure in accord- ance with the following formula: V = ZKCW .............................. (14-1) The value of "K" shall be not less than that set forth in Table No. 23-H. The value of "C" shall be determined in accordance with the following formula: 0.05 · C- . ............................. (14-2) xYT Except as provided in Table No. 23-I, the maximum value of "C" need not exceed 0.10. For all one- and two-story .build- ings the value of "C" shall be considered as 0.10. "T" is the fundamental period of vibration of the structure in seconds in the direction under consideration. Prop,e, rl~, sub- stantiated technical data for establishing the period'T may be submitted. In the absence of such data, the value of "T" for buildings shall be determined by the following formula: 0.05h. T -- --. ............................. (14-a) VD EXCEPTION: In all buildings in which the lateral force resisting system consists of a moment-resisting space frame which resists 100 per cent of the required lateral forces and which frame is not enclosed by or adjoined by more rigid elements which would tend to prevent the frame from re- sisting lateral forces: T = 0.10N ........................... (14-3A) The total lateral force "V" shall be distributed in the height of the structure in the following manner: F, = .004V ................ . ..... (14-4) "Ft" need not exceed 0.15 "V" and may be considered as 0 for values (D~)of 3 or less, and 120 ]970 EDITION (V - F,) w,h, EXCEPTION: One- and two-story buildings shall have uniform distribution. At each level designated as "x,' the force "Fd' shall be applied' over the area of the building in accordance with the mass distribution on that level. 2. Lateral force on parts or portions of buildings or other structures. Parts or portions of buildings or structures anti their anchorage shall be designed for lateral forces in accord- ance with the following formula: Fv = ZCvW~ .......... : .................... (14-6) The values of "Cv" are set forth in Table No. 23-I. The distribution of these forces shall be ficcording to the gravity loads pertaining thereto. 3. Pile foundations. Individual pile or caisson footings of. every building or structure shall be intercohnected by ties each of which can carry by tension and compression a hori- zontal force equal to 10 per cent of the larger pile cap load- ing unless it can be demonstrated that equivMent restraint can be provided by other approved methods. (e) Distribution of Horizontal Shear. Total shear in any horizontal plane shall be distributed to the various elements of the lateral force resisting system in proportion to their rigidities considering the rigidity of the horizontal bracing system or diaphragm. Rigid elements that are assumed not to be part of the lateral force resisting system may be incorporated into buildings pro- vided that their effect on the action of the system is con- sidered and provided for in the design. (f) Drift. Lateral deflections or drift of a story relative to its adjacent stories shall be considered in accordance with accepted engineering practice. (g) Horizontal Torsional Moments. Provisions 'shall be made for the increase in shear resulting from the horizontal torsion due to an eccentricity between the center of mass and the center of rigidity. Negative torsional shears shall be neglected. Where the vertical resisting elements depend on diaphragm action for shear distribution at any level, the shear- resisting elements shall be capable of resisting a torsional moment assumed to be equivalent to the story shear acting with an eccentricity of not less than five per cent of the maxi- mum building dimension at that level. SECTION 2314 Earthquake .................. ( 14-5)' Regulations (Continued) 121 SECT~O. 2314 Earthquake Regulations (Continued) UNIFORM BUILDING CODE (h) Overturning. Every building or structure shall be designed to resist the overturning effects caused by the wind forces and related requirements specified in Section 2308, or the earthquake forces specified in this Section, whichever governs. EXCEPTION: The axial loads fiom earthquake forces on.vertical elements and footings in every building or struc- ture may be modified in accordance with the following 'provisions: 1. The overturning moment, "M", at the base of the building or s,tructure shall be determined in accordance with the following formula: M=](F,b, q- ~ F,h,) ................. '_...(14-7) : i=1 WHERE: ]=0.6 --. ............................. : ...... (14-8) ~yT The' value of :']" need not be more than 1.00. For stru~: tures other than buildings the value of "]" shall be not less than 0.45. 2. The overturning moment, "M~", at any level desig- nated as "x" shall be determined in accordance with the following: M~=], IF, (h~ - h0 d- ~ F, (h, - h.O] ....(14-9) WHERE: 1, :--lq- (1--]) ~l ............... 14-10) At any level the incremental changes of the design over- turning moment, in the stoW under consideration, shall be dis- tributed to' the various resisting elements in the same propor- tion as the distribution of the shears in the resisting system. Where other vertical members are provided which are capable of partially resisting the overturning moments, a resdistribu- tion may be made to these members if framing members, of sufficient strength and stiffness to transmit the required loads are provided. Where a vbrtieal resisting element is discontinuous, the overtuming moment carried by the lowest stow of that ele- ment shall be carried down as loads to the foundation. (i) Setbacks. Buildings having setbacks ~vherein the plan dimension of the tower in each direction is at least 75 124 1970 EDITION per cent of the corresponding plan dimension of the lower part may be considered as a uniform buildin~ without set- backs for the purpose of determining seismic ~orces. For other conditions of setbacks the tower shall be de- signed as a separate building using the larger of the seismic coefficients at the base of the tower determined by consider- ing the tower as either a separate building for its own height or as part of the over-all structure. The resulting total shear from the tower shall be applied at the top of the lower part of the building which shall be otherwise considered sepa- rately for its own height. EXCEPTION: Nothing in this subsection shall be deemed to prohibit the submission of properly substantiated technical data-for establishing the lateral design forces by a dynamic analysis. (i) Structural Systems. 1. Design requirements. Buildings more than 160 feet in height shall have a ductile moment- resisting'space frame capable of resisting not less than 25 per cent of the required seismic force for the structure as a whole. All buildings designed with a horizontal force factor "K" of 0.67 or 0.80 shall have a ductile moment-resisting space frame of structural steel (complying with Section 2722 for buildings in Seismic Zones No. 2 and No. 3 or Section 2723 for buildings in Seismic Zone No. 1) or of reinforced concrete (complying with Section 2630 for buildings in Seismic Zones No. 2 and No. 3 or Section 2631 for buildings in Seismic Zone No. 1 ). EXCEPTIONS: 1. Buildings more than 160 feet in height in Seismic Zone No. '1 may have concrete shear walls de- signed in conformance with Section 2632 of this Code in lieu of a ductile moment-resisting space frame, provided a "K" value of 1.00 or 1.33 is utilized in the design. 2. Other structural concepts may be approved by the Building Official when evidence is submitted showi.n~ that equivalent ductility and energy absorption are proviued. Moment-resisting space frames and ductile moment-resist-. ing space frames'may be enclosed by or adioined by more rigid elements which would tend tO prevent the space frame from resisting lateral forces Where it can be shown that the action or failure of the more rigid elements will not impair the vertical and lateral load-resisting ability of the space frame. 2. Construction. The necessary ductility for ~ ductile mo- ment-resisting space frame shall be provided by .a frame of structural steel with moment-resisting connections (comply- ing with Section 2722 for buildings in Seismic Zones No. 2 and No. 3 or Section 2723 for buildings in Seismic Zone No. 1) or by a reinforced concrete frame (complying With Section 2630 for buildings in Seismic Zones No. 2 andNo. 3 or Section 2631 for buildings in Seismic Zone No. 1). Shear walls in buildings where K = 0.80 shall be composed of axially loaded bracing members of A36, A440, A441, A572 125 SECTION 2314 Earthquake Regulations (Continued) SECTION 2314 Earthquake RegulaUons (Continued) UNIFORM BUILDING CODE (except Grades 60 and 65) or A588 Grades A, B or C struc- tural steel; or reinforced concrete bracing members or wails conforming with the requirements of Section 2632. Reinforced concrete shear walls and reinforced concrete braced frames for all buildings shall conform to the require- ments of Section 2632. In buildings where K = 0.67 and K 0.80, all structural elements below the base required to trans- mit seismic forces to' the foundation shall be composed of structural steel (complying with Section .2722 for buildings in Seismic Zones i'qo~ 2 and No. 3 or Section 2723 for buildings in Seismic Zone No. 1) or by reinforced concrete (complying with Section 2630 for buildings in Seismic Zones No. 2 and No. 3 or with Section 2631 for buildings in Seismic Zone No. 1 and with Section No. 2632 for buildings in Seismic Zones Nos. 1, 2, and 3). (k) Design Requirements. 1. Building separations. All portions of structnres shall be designed and constructed to act as an integral, unit in resisting horizontal forces unless 'sepa- rated structurally by a distance sufficient 'to avoid contact under deflection from seismic action or wind forces. 2. Minor alterations. Minor structural alterations may be made in existing buildings and other structures,~ but the re- sistance to lateral forces shall be not less than that before such alterations were made, 'unless the building as altered meets the requirements of this Section of the Code. 3. Reinforced masonry or concrete. All elements within the structure which are of masonry or concrete and which .resist seismic 'forces or movement shall be reinforced so as to qualify · as reinforced masonry or concrete under the provisions of Chapters 24 and 26. Principal reinforcement in masonry shall be spaced 2 feet maximum on center in buildings using a moment-resisting space frame. 4. Combined vertical and horizontal forces. In computing the effect of seismic force in combination with vertical loads, gravity load stresses induced in members by dead load plus design live load, except roof live load, shall be considered. 5. Exterior elements. Precast, nonbearing, non-shear wall panels~or other elements which are attached to, or enclose the exterior, shall accommodate movements of the structure resulting from lateral forces or temperature changes. The con- crete I~anels or other elements'shall be supported by means of poUrec~-in-place concrete or by mechanicai fasteners in accord- ance with the following provisions: A. Connections and panel ioints shall 'allow for a relative movement between stories of not less than two times stow' drift caused by wind or seismic forces; or % inch whichever is greater. B. Connections shall have sufficient ductility and rotation capacity so as to preclude fracture of the concrete or 'brittle 126' 1970 EDITION SECTIONS 2314-2315 failures at or near we]ds. Inserts in concrete shall be attached Earthquake to, or hookcc~ around reinforcing steel, or otherwise terminate(] Regulations so as to effecti¥cly transfer forces to the reinforcing steel. (Continued) C. Connections to permit movement in the plane of the' panel for story drift may be properly designed sliding connec- tions using slotted or oversize holes or may be connections which permit movement by bending of steel. (1) Earthquake Recording Instrumentations. For ~ai'th- quake recording instrumentations see Appendix, Section 2314 (1).' Sec. 2315. In addition to other design requirements of this Heliport and Chapter, heliport and helistop landing or touchdown areas ~efist0p £anding shall be designed for the maximum stress induced by the fol- ~eas lowing: 1. Dead load plus actual Weight of the helicopter. 2. Dead load plus a single COncentrated impact load cover- ing i square foot of .75 times the fully loaded weight of the helicopter if it is equipped with hydraulic type shock absorb- - ers, or 1.5 times the fully loaded weight of the helicopter if it is equipped with a rigid or skid type landing gear. 3. The dead load plus a uniform live load of 100 pounds per s(~uare foot. The required live load may be reduced in accoraance with the formula in Section 2306. 127 :-...?:.:-~..~:.... ~ O.R R E,C T/.O N' N O,"':~' C E ¢ cn'Y o~: BUILDING · DEPART/~E-~I~ T~ ~o~,o~ ~/5 Sub Div. . Blk. / . .~t ' . You are hereby required to make g c r~tio~ at the above l~a~on: · ' ~ Completion~ate ~r Co~ections ~ /' " 0 ~t~. f/~~ ~~~~o~ 326-3727 32-G I-- Z uJ U. O z -J iii ,_1 626 1991 UNIFORM BUILDING CODE 1991 UNIFORM BUILDING CODE 3301 · ,' Chapter 33 EXITS General Sec. 3301. (a) Scope and Standards of Quality. Every building or portion thereof shall be provided 'with exits as required by this chapter. The standards listed below labeled a"U.B.C, standard" are also listed in Chapter 60, Part II, and are part of this code. Th6 other standards listed below are guideline standards and as such are not adopted as part of this code (see Sections 6002 and 6003). 1. Power doors A. U.B.C. Standard No. 33-i, Power-operated Exit Doors B. U.B.C. Standard No. 43-13, Horizontal SlidingFire Doors Used in an Exit 2. Stairway numbering system A. U.B.C. Standard No. 33-2, Stairway Identification 3. Hardware A. U.B.C. Standard No. 33-4, Panic Hardware' (b)'Definitions. For the purpose of this chapter, certain terms are defined as fol- lows: BALCONY, EXTERIOR EXIT, is a landing or porch projecting from the wall of a building, and which serves as arequired exit. The long side shall be at least 50 percent open, and the open area above the guardrail shall beso distributed as to pre- vent the accumulation of smoke or toxic gases. CONTINENTAL SEATING is the configuration of fixed seating where the number of seats per row exceeds 14 and requir~ed exits from the seating area are side exits.. EXIT is a continuous and unobstructed m~ans of egress to a public ~vay and shall include intervening aisles,'doors, doorways, gates, corridors, exterior exit balco- nies, ramps, stairways, smokeproof enclosures, horizontal exits, exit passage- ways, exit courts and yards. EXIT COURT is a yard or court providing access to a public 'way for one or more required exits. EXIT PASSAGEWAY is an enclosed exit connecting a required exit or exit court with a public way. HORIZONTAL EXIT is an exit from one building into another building on ap- proximately the same level, or through or around a wall constructed as required for a two-hour occupancy separation and which completely divides a floor into two or more separate areas so as to establish an area of refuge affording safety from fire or smoke coming from the area ~from which escape is made. · MULTITHEATER COMPLEX is a building or portion thereof containing two or more motion picture auditoriums which are served by a common lobby. 627 3301-3302 1991 UNIFORM BUILDING CODE PANIC HARDWARE is a door-latching assembly incorporating an unlatching device, the activating portion of which, e. xtends across at least one half the width of the door leaf on which it is installed. · PRIVATE STAIRWAY is a stairway serving one tenant only. PUBLIC WAY is any street, alley or similar parcel of land essentially unob- structed from the g~ound to the sky which is deeded, dedicated or otherwise perma- nently appropriated to the Public for public. Use an.d having ~ clear width of not less than 10 feet. . SPIRAL STAIRWAY is a stairway having a closed circular form in its.plan view with uniform section Shaped treads at/ached to and radiating about a mini- mum diameter supporting column. The ~ffective tread is delineated by the nosing radius line, the exterior arc (center line of railing) and the overlap radius line (nos- ing radius line of tread above). Effective tread dimensions are taken aloi~g a line perpendicular to the center linc of the tread. (c) Exit Obstruction. Obstructions shall not be piaced in the required width of an exit except projections permitted by this chaptdr. (d) Changes. in Elevation. Within a building, changes in elevation of less than 12 inches along any exit serving an occup~ant load of 10 or more shall be bY ramps. EXCEPTION: Group R, Division 30~:cupancies and along aisles adjoining seating areas. · (e) Yards, Patios and Courts, Yards,.patios, courts and similar outdoor areas accessible to and usable by the building occupants shall be provided with exits as required by this chapter. The occupant logd of such outdoor areas shall be assigned by the building official in accordance with their anticipated use. When outdoor areas are to be used by peroons in.addition to the occupants of the building, and exits from the outdoor areas pass through the building, exit requirements for the building shall be based on the sum of the occupant loads of the building plus the outdoor areas. ' '' · EXCEPTIONS: I. Outdoor areas used exclusively for service of the building may have only one exit. 2. Outdoor areas associated With Group R, Division 3 0c~upancies. (f) Building Accessibility. In addition t6 provisions of ibis chapter, exits which provide access to, or egress from, buildings for persons with disabilities shall also comply with Chapter 31. (g) Elevators or Escalators. Elevators or escalators shall not be used as a re- quired exit. Occupant Load Sec. 3302. (a) Determination of Occupant Load. In determining the occupant 10ad, all portions of a building shall be presumed to be occupied·at the same time. EXCEPTION: Accessory use areas Which ordinarily are used only by persons '*.'wh0 occupy the m~in areas of an occupancy shal'l b~ provided with exits as though they are completely occupied, but their occupant load need noi be included in com- puting the total occupant load of the building. The occupant load for a building shall be determined in accordance with the fol- lowing: .:', .... . 628 1991 UNIFORM BUILDING CODE 3302-3303 1. General. For areas without fixed seats, the occupant load shall not be les~than the number determined by dividing the floor area assigned to that use by the occu- pant load factor set forth in Table No. 33-A. Where an intended use is not listed in ,Table No. 33-A, the building official shall establish an occupant load factor based on a listed use which most nearly resembles the intended use. For a building or portion thereof which has more than one use, the occupant load shall be determined by the use which gives the largest numberof persons. The occuPant load for buildings or areas containing two or more occupancies shall be,determined by adding the occupant loads of the' various use areas as com- puted in accordance with the applicable provisions of this section. '~ 2~ Fixed seating. For areas having fixed seats and aisles, the occupant load shail be determined by the number of fixed seats installed therein. The required width of =aisles serving fixed seats shall not be Used for any other pbrpose. . For areas having fixed benches or pews, the occupant load shall not be less than the number of seats based on one person .for each 18 inches of length of pew or bench. Where booths are used in dining areas, the occupant load shall be based on one person for each 24 inches of booth length or major portion thereof. 3. Reviewing stands, grandstands and bleachers. The occupant load for re- viewing stands, grandstands and bleachers shall be calculated in accordance with this section and the specific requirements contained in Section 3322. (b) Maximum Occupant Load. The maximum occupant load for other than an assembly use shall not exceed the capacity of exits as determined in accordance with this chapter. The maximum occupant load for an assembly use shall not exceed the occupant load as determined in accordance with Section 3302 (a). EXCEPTION: The occupant load for an assembly building or portion thereof '; ma)/b~ increased, when approved by the building official, if all the requirements of this code are met for such increased number of personsl The building official may re- quire an approved aisle, seating or fixedequipment diagram to substantia[e such an increase, and may require that such diagram be posted. (c) Posting of Room Capacity. Any room having an occupani load of 50 or more where fixed seatS are not installed, and which is used for classroom, assembly or similar purpose, shall have the capacity of the room posted in a conspicuous place on an approved sign near the main exit from the room. Such signs shall be maintained legible by the owner or the owner's authorized agent and shall indicate the number of occupants permitted for each room use. ' (d) Revised Occupant Load. After. a building is occupied, any change in use or ihcrease in occupant load shall comply with this chapter. See Section 502. Exits Required Sec. 3303. (a) Number of Exits. Every building or usable portion thereof shall have at least one exit, not less than two exits where required~by Table No. 33-A and additional exits as required bY this subsection. , .. 629 33O3 1991 UNIFORM BUILDING CODE For purposes of this section, basements and occupied roofs shall be provided with exits as required for stol-les. EXCEPTIONS: Occupied roofs on Group R, Division 3 Occupancies may have one exit if such occupied areas are less than 500 square feet and are located no higher than immediately above the second story. · Floors compiying with the provisions for mezzanines as specified in Section 1717 shall be provided with exits as specified therein. The second story shall be provided with not less than two exits when the occu- pant load is l0 or more. Occupants on floors above the second story and in base- ments shall have access to not less than two ·separate exits from the floor or basement. EXCEPTIONS: I..Tw~ or more dwelling units on the·second story or iff a base- ment may have access to only one common exit when the total occupant load served by that exit does not exceed 10. 2. Except as provided in Table No. 33-A, only one exit need be provided from the s~cond floor or a basement within an individual dwelling unit or a Group R, Division' 3 congregate residence. 3. When the third floor within an individual dwelling unit or a Group R, Division 3 congregate residence does not exceed 500 square feet, only one exit need be pro- vided from that floor. 4. Floors and basements used exclusively for service of the building may have one exit. For the purposes of this exception, storage rooms, laundry rooms, maintenance offices and simi!ar uses shall not be consider'ed as providing service to the building. 5. Storage rooms, laundry rooms and maintenance offices not exceeding 300 square feet in floor area may be provided with only one exit. 6. Elevator lobbies may have one exit provided the use of such exit does not require keys, tools, special knowledge or effort. For special requirements see the following Se6tions: Group A, Section 3317; Group E, Section 3318; Group H, Section 3319; Group I, Section 3320; Rooms Coutaining Fuel-fired Equipment and Cellulose Nitrate Handling Rooms, Section 3321; Reviewing Stands, GrandStands and Bleachers, Section 3322; Laboratories, .Se.ctions 702 (c) and 802 (d); and Open Parking Garages, Section 709 (g). For stage exits, see Section 3903 (f). Every story or porti0nthereof having an occupant load of 501 to 1,000 shall not have less than three exits. Every story or portion thereof having an occupant load of 1,001 or more shall not have less than four exits. The number of exits required from any story of a building shall be determined by using the~occupant load of that. story plus the percentages of the occupant loads of floors which exit into the level under consideration as follows: 1~. Fifiy percent of the occupant load in the first adjacent story above and the first adjacent story below, when a story below exits through the level under Consider- ation. 2. Twenty-five percent 0fthe occupant load in the story immediately beyond the first adjacent story. 630 1991 UNIFORM BUILDING CODE 3303 The maximum number of exits required for any story shall be maintained until egress is provided from the structure. (Seej Section 3311 .) Width. The total width of exits in inches shall not be less than the total occu- (b) pant load served by an exit multiplied by 0.3 for stairways and 0.2 for other exits nor less than specified elsewhere in this code. Such Widths of exits shall be divided ap- proximately equally among the separate exits. The maximum exit width required from any story of a building shall be main- tained. (~) Arrangement Of Exits. If only two exits are required, they shall be placed a distance apart equal to not less than one hal f of the length of the maximum overall diagonal dimension of the building or area to be served measured in a straight line between exits. EXCEPTION: Exit separations may be measured along a direct line Of travel within the exit corridor when exit enclosures are provided as a portion of the required exit and are interconnected by a one-hour hre-res~mve corodor conform ng to the r - quirements of Section 3305. Enclosure walls shall not be less than 30 feet apart at any point in a direct line of measurement. . Where three or more exits are required, at least two exits shall be placed a dis- tance apart equal to not less than one half of the length of the maximum overall di- agonal dimension of the building or area to be served measured in a straight line between the exits, and the additional exits shall be arranged a reasonable distance apart so that if one becomes blocked the others will be ava~ilable. (d) Distance to Exits. The maximum distance °f travel from any point to an ex- terior exit door, horizontal exit, exit passageway or an encloged stairway in a build- ing not equipped with an automatic sprinkler system throughout s_hall not exceed 150 feet, or 200 feet in a building equipped with an automatic sprinkler system throughout. These distances may be increased a maximum of 100 feet when the increased travel distance is the last portion of the travel distance and is entirely within a one-hour fire-resistive corridor complying with Section 3305. See Section 3318 for Group E Occupancy and Section 3319 for Group H Occupancy travel dis- tances. In a o~e-story Group B, Division 4 Occupancy classified as a factory or ware- house and in one-story airplane hangars, the exit travel distance may be increased tO 400 feet if the building is equipped with an automatic sprinkler system through- out and provided with smoke and heat ventilation as specified in Section 3206. In an open parking garage as defined in Section 709, the exit travel distance may · be increased to 250 feet Which may be measured to open stairways which are per- mitted in accordance with Section 3309 (a). (e) Exits through Adjoining Rooms. Romns'may have one exit through an ad- joining or intervening room which provides a direct, obvious and unobstructed means of trax;el to an exit corridor; exit enclosure or until egress is provided from the buildlng, provided the total distance of travel does not exceed that permitted by other provisions of this code. In other than dwelling units, exits shall not pass through kitchens, store rooms, restrooms, closets or spaces used for similar pur- poses. 631 3303-33O4 199'1 UNIFORM BUILDING CODE EXCEPTIONS: 1. Roomswithindwellingunitsmayexitthroughmorethan0ne intervening room. . 2. Rooms with a cumulative occupant load of 10 or less may exit through more than one intervening room. Foyers, lo.bbies and reception rooms constructed as required for corridors shall not be construed as intervening rooms. Doors Sec. 3304. (a) General. This section shall apply to every exit door serving an area having an occupant load of 10 or more, or serving hazardous rooms or areas, except that Subsections (c), (i), (j) and (k) shall apply to all exit doors regardless of occupant load. Buildings or structures used for human occupancy shall have at least one exterior exit door that meets the requirements of Subsection (f). Doors and landings at doors which are located within an accessible route of travel shall also comply with Chapter 31. ~ . (b) Swing and Opening Force. Exit doors shall be'ofthe pivoted or side-hinged swinging type. Exit doors shall swing in the direction of exit travel when serving any hazardous area or when ,serving an occupant load of 50 or more The door latch shall release when subjected to a 15-pound force, and the door shall be set in motion when subjected to a 30-pound force. The door shall swing to full-open position when subjected to a 15-pound force. Forces shall be applied to the latch side. See Section 4507 for doors swinging over public proPerty. EXCEPTIONS: I. Group I, Division 3 Occupancy used as a place of detention. 2. Doors within or serving an individual dwelling unit. 3. Special door conforming with Subsection (h). Double-acting doors shall not be used as exits when any of the following condi- tions exist: 1. The occupant load served by the door is 100 or more.' 2. The door is part of a fire assembly. 3. The door is part of a smoke~ and draft-control assembly. 4. Panic hardware is required or provided on the door. A double-acting door shall be provided with a view panel of not less than 200 square inches. ' (c) Type ofLock or Latch. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. EXCEPTIONS: 1. In Group B Occupancies, key-locking hardware: maybe used on' the main exit when the main exit consists of a single door or pair of doors if there is a readily visible, durable sign on or adjacent to the door stating THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS· The sign shall be in letters not less than I inch high on a contrasting background. When unlocked, the single door or both leaves of a pair of doors must be free to sw!ng without operation of any latch- ing device. The use of this exception may be revoked by the building official for due cause. 2. Exit doors from individual dwelling units; Group R, Division 3 congregate resi- dences; and guest rooms of Group R Occupancies having an occupant load of 10 or 63~ 1991' UNIFORM BUILDING CODE 3304 less may be provided with a night latch, dead bolt or security chain,'pmvided such devices are openable from the inside without the use of a key or tool and mounted at a height not to exceed 48 inches above the finished floor. Manually operated edge- 6r surface-mounted flush bolls and surface bolts are prohibited. When exit doors am used in pairs and approved automatic flush bolts are used, the door leaf having the automatic flush bolts shall have no door knob or surfacer_mounted hardware. The unlatching of any leaf shall not require more than one operation. · ~ EXCEPTIONS: I. Group R, Division 3 Occupancies. 2. When a pair of doors serving a room not normally occupied are needed ?or the ' ' . movement of equipment, manually operated edge or surface bolts may be used and a door closer need not be provided on the inactive leaf. '(d) Panic Hardware. Panic hardware, when installed, shall comply with the re- quirements of U.B.C. Standard No. 33-4. The activating member shall be mounted at a height of not less than 30 inches or more than 44 inches above the floor. The unlat~:hing force shall not exceed i5 pounds when applied in the direction of exit travel. When balanced doors are used and panic hardware is required, panic hardware shall be of the push-p/~d type and the pad shall not extend across more than one half -of the width of the door measured from the latch side. (e) Special Egress-control Devices. When. approved by the building official, exit doors in Group B, Division 2 Occupancies may be equipped with approved listed special egress-control devices of the time-delay type, provided the building is protected throughout by an approved ~iutomatic sprinkler system and an ap- proved automatic smoke-detection system. Such devices shall con form to all of the .followingi 1. Automatically. deactivate the egress-control device upon activation of either th6 sprinkler system or the detection system. .. 2. Automatically deactivate the egress-control device upon loss of electrical power t° any one of the following: . A. The egress-control device. B. The smoke-detection system. '· · ~C. Exit illumination as required by Section 3313. 3. Be capable of being deactivated by a signal from a switch located in an ap- proved location. 4. Initiate an irreversible p?ocess which will deactivate the egress-control device whenever a manual force of not more than 15 pounds is applied for two seconds to the panic bar or other door-latching hardware. The egress-control device shall deactivate within an approved time period not to exceed a total of 15 seconds. The time delay established for each egress-control device shall not be field adjustable. 5. Actuation of the panic bar or other door-latching hardware shall activate an audible signal at the door. 6. The' unlatchirlg shall not require more than one operation. :A sign shall be provided on the door located above and within 12 inches of the pan!c bar or other door-latching hardware reading: 633 3304 1991 UNIFORM BUILDING CODE KEEP PUSHING. THIS DOOR WILL OPEN IN SECONDS. ALARM WILL SOUND. Sign letter shall be at least I inch in height and shall have a stroke of not less than 1/s inch. . RegardleSs of the means of deactivation, relocking of the egress-control device shall be by manual means only atthe door. (0 Width and Height. Every required exit doorway shall be of a size as to per- mit the installation of a door not less than 3 feet in width and not less than 6 feet 8 inches in height. When installed, exit doors shall be capable of opening so that the clear width of the exit is not less than 32 inches. In computing the exit width re- quired by Section 3303 (b), the net dimension of the exitway shall be used. (g) Door Leaf Width. A single leaf of an exit door shall not exceed 4 feet in width. " (h) Special Doors. Revolving, sliding and overhead doors shall not be used as required exits. EXCEPTION: Horizontal sliding doors complying with U.B.C. Standard No. 43-13 may be used in: A. Elevator lobbies. B. Smoke barriers of Group I, Division 1.1 Occupancies. Power-operated doors complying with U.B.C~'Standard No. 33-1 may be used for exit purposes. Such doors when swinging shall have two guide rails installed on the swing side projecting out from the face of the doorjambs for a distance not less than the widest door leaf. Guide rails shall not be less than 30 inches in height with solid or meshpanels to prevent penetration into door swing and shall be capable of resisting a horizontal load at top of rail of not less than 50 pounds per lineal foot. EXCEPTIONS: 1. Walls or other type separators may be used in lieu of the above guide rail, provided all the criteria are .met. 2. Guide rails in industrial or commercial occupancies not accessible to the public may conform with the exception to the third paragraph of Section 1712. 3.Doors swinging toward flow of traffic shall not be permitted for use by untrained pedestrian traffic unless actuating devices start to function at least 8 feet 11 inches beyond the door in an open position and guide rails extend 6 feet 5 inches beyond the door in an open position. Clearances for guide rails shall be as follows: 1. Six inches maximum between rails and leading edge of door at the closest point in its arc of travel. 2. Six inches maximum between rails and the door in an open position. 3. Two inches minimum between rail at hinge side and door in an open position. 4. Two inches maximum .between freestanding mils and jamb or other adjacent surface. (i) Floor Level at Doors. Regardless of the occupant load, there shall be a floor or landing on each side of a door. When access for persons with disabilities is re- quired by.Chapter 31, the floor or landing shall not be more than ~/2 inch lower than the threshold of the doorway. When such access is not required, such dimension 634 1991 UNIFORM BUILDING CODE 3304-3305 shall not exceed 1 inch. Landings shall be level dxcept for exterior landings, which may have a slope not to exceed ~/4 inch per f. oot~ EXCEPTIONS: 1. InGroupR, Division3,andGroupMOccupanciesandwith- in individual units of Group R, Division 1 Occupancies: A. A door may open at the top step of an interior flight of stairs, provided the door does not swing over the top step. B. A door may open at a landing that is not more than 8 inches lower than the floor level, provided the door does not swing over the landing. C. Screen doors and storm doors may swing over stairs, steps or landings. 2. Doors serving building equipment rooms which are not normally occupied. (j) Landings at Doors. Landings shall have a width not less than the width of the stairway or the width of the door, whichever is the greater. Doors in the fully open position shall not reduce a required dimension by more than 7 inches. When a land- ing serves an occupant load of 50 or more, doors in any position shall not reduce the landing dimension to less than one half its required width. Landings shall have a length measured in the dii'ection of travel of not less than 44 inches. EXCEPTION: In Group R, Division 3, and Group M Occupancies and within · individual units of Group R, Division I Occupancies, such length need not exceed 36 inches. ' · A landing which has no ~djoining door shall comply with Section 3306 (g). (k) Door Identification. Glass doors shall conform to the requirements speci- fied in Section 5406. Exit doors shall be marked so that they are readily distinguishable from tbe adja- cent construction. (1) Additional Doors. When additional doors are provided for egress purposes, they shall' conform to all provisions of this chapter. EXCEPTION: Approved revolving doors having leaves which will collapse un- der opposing pressures may be used in exit situations, provided: A. Such doors have a minimum width of 6 feet 6 inches. B. At least one conforming exit door is located adjacent to each revolving door. C. The revolving door shall not be considered to l~rovide any exit width. Corridors and Exterior Exit Balconies Sec. 3305. (a) General. This section shall apPly to every corridor serving as a required exit for an occupant load of 10 or moreexcept that Subsection (b) shall ap- ply to all corridors. For the purposes of this section, the term "corridor" shall in-* clude "exterior exit balconies" and any covered or enclosed exit passageway, · including walkways, tunnels and malls. Partttlons, rafts, counters and stmdm' space dividers not over 5 feet 9 inches in h~ght abdve the floor Shall not be construed to form corridors. Exit corridors shall not be interrupted by intervening rooms. EXCEPTION: Foyers, lobbies or reception rooms constructed as required for ' corridors shall not be construed as intervening rooms. Corridors which are located within an accessible route of travel shall also com- ply with Chapter 31. 635 3305 1991 UNIFORM BUILDING CODE For Group I Occupancies see Section 3320 (c). " " (b) Width. The minimum corridor width shall be determined as specified in Sec- tiori 3303 (b), but shall not be less than 44 inches; except as specified herein. Corri- dors serving an occupant load of 49'or less shall not be less than 36 inches in width. For special requirements for Groups E and I Occupan~.ies, see Sections 3318 and 3320. (c) Height. Corridors and exterior exit balconies shill ha~,e a clear l~eight of not less than 7 feet measured to the lowest projection from the ceiling. (d) Projections. The required width of corridors sha!l be,unobstructed. · , EXCEPTION: ~landrails. and doors, when fully opened, shall not reduce the re- quired width by more than 7 inches. Doors in any position shall not reduce t~e re- quired width by more than one half. Other nonstructural projections such as trim and similar decorative features may project into the required width 11/~ inches on each side. · , (~) Access to Exits. When more than one exit is required, they shall be so ar- ranged that it is possible to g~ in either direction from any po!nt iri acorridoi' to a separate exit, except for dead ends not exceeding 20 feet in li~ng!h: (f) Changes in Elevation. When a corridor or exterior exit balcony is accessible to the handicapped, changes in elevation of the floor shall.be made by. means of a ramp, except as provided for doors by Section 3304 (i).. (g) Construction. Walls of corridors serving a Group R, Division 1 or Group I Occupancy having an occupant load of 10 or more and walls of corridors serving other occupancies having an o~cupant load of 30 or moi'e Shall be of not less than one-hour fire-resistive construction a~d the ceilings shall not be less ~han that re- quired for a one-hour fire-resistive floor or roof system~ ' EXCEPTIONS: 1. One-story buildings housing Groul~ ~, Division 4 Occupan- cies. 2. Corridors more than 30 feet in Width where occupancies served by such corri- dors have at least one exit independent from the corridor~ (S~e Chapter 56 for covered malls.) 3. Exterior sides of ~xterior exit balconies. ' 4. In Group I, Division 3 Occupancies such as jails, prisons, reformatories and similar buildings'with open-barred cells forming corrid6r walls, the corridors and cell doors need not be fire resistive. . · " ' ' ~ "' 5. Corridor walls and ceilings need not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sp~'!nkler system throughout and smoke detectors are installed Within the corridor in accordance with their listing. 6. In other than Type I or II construction, exterior exit balcony roof assemblies may he of heavy-timber construction wiihout concealed spaces. 7. Within office spaces occupied by a single tenant, partial height partitions which form corridors and which do not exceed 6 feet in height need not be fire resis- tive, provided they are constructed in accordance with Section !705 and are not more than three fourths of the floor-to-ceiling height. When the ceiling of the entire story is an element of a one-hour fire-resistive floor or roof system, th6 corridor walls may terminate at the ceiling. When the 636 1991 UNIFORM BUILDING CODE 3305 room-side fire-resistive membrane of the corridor wall is carried through to the un- derside of a fire-resistive floor or roof above, the corridor side of the ceiling may be protected by the use of ceiling materials as required for one-hoUr floor or roof sys- tem construction or the corridor ceiling may be of the same construction as the cor- ridor walls. · ' Ceilings of noncombustible construction may be suspended below the fire-re- sistive ceiling. For wall and ceiling finish requirements, see Table No. 42-B. Eot restrictions on the use of corridors to convey air, see Chapter 10 of the Me- Chanical Code. (h) Openings. 1. Doors. When corridor walls are r6quired to be of one-hour fire-resistive construction by Section 3305 (g), every interior door opening shall be protected by a tight-fitting smoke- and draft-control assembly having a fire-pro- tection rating of not less than 20 minutes when tested in accordance with U.B.C. Standard No. 43-2. Said doors shall not have louvers. The door and frame shall bear an approved label or other identification shOwing the rating thereof; the name of the manufacti~rer and the identification of the service conducting the inspection of ma- terials and workmanship at the factory during fabrication and assembly. Doors shall be maintained self-closing or shall be automatic closing by actuation of a smoke detector in accordance with Section 4306 (b)., Smoke- and draft-control door assemblies shall be provided with a gasket so installed as to provide a seal where the door meets the stop on both sides and across the top. EXCEPTIONS: I. Viewports may be installed if they require a hole not larger than I inch in diameter through the door, have at least a ~/a~inch-thick glass disc and ~ the holder is pi: metal which will not melt out when subject to temperatures of 1,700°F. 2. Piotection of openings in the interior walls of exterior exit balconies is not re- quired when it is possible to exit in two directions. 2. Openings other than doors. Where corridor walls are required to be of one-hour fire-resistive con§truction by Section 3305 (g), interior openings for oth- er than doors or ducts shall be protected by fixed glazing listed and labeled for a fire.protection ratin~ ofat least three-fourths hour in a~cordance ~ith Section 4306 (i). The total area of all openings, other than doors, in any pbrtion of an interior cor- ridor shall not ekceed 25 percent of the area of the corridor wall or,he room which it · is separating from ·the corridor. For duct openings, see Section 4306. EXCEPTION: P.rotection of open ngs in the interior walls of exterior exit balco- nies is not required when it is possible to exit.!~ two directions.. (i) Location on Property. Exterior exit balconies, shall not be located in.areas where openings are not permitted or where openings are required to be protected due to location on the property. . ' (j) Elevators. Elevators opening into a corridor serving a Group R, Division I or Group I Occupancy having an occupant load of 10 or more, or a corridor serving other occupancies having an occupant load of 30 or more shall be provided with an elevator lobby at each floor containing such a corridor. The lobby shall completely separate the elevators from the corridor by construction conforming to Section 637 3305-3306 o ~1991 UNIFORM BUILDING.CODE 3305 (g) and all openings into the lobby wall contiguous with the corridor shall be protected as required bY Section 3305 (h). ~ .~' ' ' - . EXCEPTIONS: 1. In office buildings classed as a Group B, Division 20ccu- pancy, separations need not be provided from a street floor lobby, provided the entire street floor is protected with an automatic sprinkler system. 2. Elevators not required to meet the shaft enclosure requirements of Section 1706. 3. When additional doors are provided in accordance with Section 5106. Elevator lobbies shall comply with Section 5106. In fully sprinklered office buildings, corridors may lead through enclosed eleva- tor lobbies if all areas of the building have access to at least one required exit with- out passing through the elevator lobby. · . Stairways , . Sec. 3306. (a) General. Every stairway having two or more risers serving any building or portion thereof shall conform to the requirements of this section. When. aisles in assembly rooms have steps, they shall conform with the provisions in Sec- tion 3315. ' ' EXCEPTION: Stairs or ladders used only to attend equipment are exempt from the requirements of th~s section. (b) Width. The minimum stairway width shall be determined as specified in Section 3303 (b), but shall not be less than 44 inches except as specified herein.' Stairwayg serying an occupant load of 49 or less shall not be less than 36 inches in width. Handrails may project into the required width'a distance of 31/2 inches from each side of a stairway. Stringers and other projections such as trim and similar decora- tive features may project into the required width' !1/2 !n~hes~ on each side. (c) Rise and Run. The rise of every step in a staii'way shall not be less than 4 inches or greater than 7 inches. Except as permitted in Subsections~(d) and (f), the run shall not be less than 11 inches as measured horizontally between the vertical planes of the furthermost projection of adjacent treads. Except as permitted in Sub- sections (d), (e) and (f), the largest tread run within any flight, of stairs shall not ex- ceed the smallest by more than 3/s inch. The greatest riser he, ight within any flight of stairs shall not exceed the smallest by more than /s ~nch. EXCEPTIONS: 1. Private stairways serving an occupant load of less than 10 and stairways to unoccupied roofs may he constructed.with an 8-inch-maximum rise and a 9-inch-minimum run. - 2. Where the bottom or top ri~er adjoins a sloping public way, walk or driveway having an established grade' and serving as a landing, the bottom or top riser may be reduced along the slope to less than 4 inches in height with the variation in height of the bottom or top riser not to exceed 3 inches in every 3 feet of stairway width. (d) Winding Stairways. In Group R, Division 3 Occupancies and in Private stairways in Group R, Division 1 Occupancies, winders may be used if the required width of run is provided at a point not more than 12 inches from the side of the stair- way where the treads are narrower, but in no case shall any width of run be less than' 6 inches.at any point. ' 638 1991 UNIFORM BUILDING CODE' 3306 (e) CircUlar Stairways. Circular stairways may be used as an exit, provided the minimum width of run is not less than 10 inches and the smaller radius is not less than twice the width of the stairway. The largest tread width or riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. (f) Spiral Stairways. In Group R, Division 3 Occupancies and in private stair- ways within individual units of Gr0up R, Division I Occupancies, spiral stairways may be installed. Such stairways may be used for required exits when the area served is limited to 400 square feet. The tread must provide a clear walking area measuring at least 26 inqhes from the outer edge of the supporting column to the inner edge of the handrail. A run of at least 7¥2 mches ts to be provided at a point 12 inches fron~ where the tread ~s the narrowest. The rise must be sufficient to provide 6-foot 6-inch headroom,The rise shall not exceed 91/2 inches. (g) Landings. Every landing Shall have a dimension measured in the direction of travel not lesg than the width of the stairway. Such dimension need not exceed 44 inches When the stair has a straight run. There shall not be more than 12 feet verti- cally between landings. For landings with adjoining doors, see Sec'tion 3304 (j). EXCEPTION: Stairs serv!ng an unoccupied roof are exempt from these provi- sions. (h) Basement Stairways. When a basement stairWay and a stairway to an upper story terminate in the same exit enclosure, an approved barrier shall be provided to prevent persons from continuing on into the basement. Directional exit signs shall be provided as specified in Section 3314. . (i) Handrails. Stairways shall have handrails on each side, and every stairway required to be more than 88 inches in width shall be provided with not less than one intermediate handrail for each 88 inches of required width. Intermediate handrails shall be spaced approximately equaliy across with the entire width of the stairWay. EXCEPTIONS: 1. Stairways less than 44 inches in width or stairways serving one individual dwelling unit in Group R, Division 1 or 3 Occupancies or a Group R, Division 3 congregate residence may have one handrail.' ~ .... 2. Private stairways 30 inches or less in height may have handrails on one side only. 3. Stairways having iess than four risers and serving one individual dwelling unit inGroup R, Division 1 or 3, or a Group R, Division 3 c°ngregate residenc, e °r serving Group M Occupancies need not have handrails. The top of handrails and hat~drail extensionS shall be placed not less than 34 in- ' ches or more than 38 inches above the nosing of treads and landings. Handrails shall be continuous the full length of the stairs and, except for private stairways, at least one handrail shall extend in the direction of the stair run not less than 12 inches beyond the top riser or less than 12 inches beyond the bottom riser. Ends shall be returned or shall terminate in newel posts or safety terminals. The handgrip portion of handrails shall not be less than 1 I/2 inches or more than 2 inches in cross-sectional dimension or the shape shall provide an equivalent grip- ping surface. The handgrip portion of handrails shall have a smooth surface with no sharp comers. 639 .3306 1991 UNIFORM BUILDING CODE' Handrails projecting from a wall shall have a space of not less than 11/2'inches between the wall and the handrail. ,, ~ ', ' · (j) Guardrails. Stairkvays open on one or both sides shall have guardrai!s as re- quired by Section 1712. ' (k) Exterior Stairway Protection. Except in Group R, Division 3 Occupancies, ali openings in the exterior wall below find within 10 feet, measured horizontally,.of' an exterior exit stairway serving a building over two stories in height or a floor level having such openings in two or more floors below shall be protected by self-clos, ing fire assembly having a three-fourths-hour fire-protection rating. Exterior stair- ways enclosed on three or more sides shall .comply with the flame-spread. requirements for interior ~tairways. EXCEPTIONS: 1. Openings may be unprotected when two separated exterior stairways serve an exterior 'exit balcony. !~i~! 2. Protection of openings is not required for open parking garages conforming to i::i:::: Section 709. ' : ' (I) Interior Stairway construction. Interior stairways shall be con?trUCted as specified in Part IV of this code. ~ "' ~ - . . Except when enclosed usable space under stairs is p~'ohibited by Section 3309 (f), the walls and soffits of the enclosed space shall' be Wotected on the enclosed side as required for one-hour fire-resistive construction. ' All required interior' ~tairways which extend to the top floor in any building four. oi' more stories in height'shall have, at the'highest po!nt of the stair shaft, an .ap- proved haich openable to the exterior not less than 16 square feet in area with a minimum dimension of 2 feet. .... ' EXCEPTION: The hatch need not be pr6vided On smokepr0of en~lgsutes or on ' stairways that extend.to the roof with an opening omo that roof. iiiil Stairways exiting directly to. the exterior of a building 'four or more stories in i~ii! height shall be provided with means for emergency entry for fire department ac- (m) Extei'ior Stairway Constructiom Exterior stairways shall be constructed as specified in Part IV of this code. Exterior stairways sh'aii not project inlo yards where openings are not permitted or protection of openings is required. Enclosed usable space under stairs shall have the walls and soffits protected on the enclosed side as required for one-hour fire-resistive cgnst~ction. iiStairways exiting directly tO the exterior of a building four or more stories in height shall be provided with means for emergency entry for fire department ac- cess.. (n) Stairway to Roof. In buildings four or more stories in height, one ~tairway shall extend to the roof surface, unless the roof has a slope greater than 4 in 12. See Subsection 3306 (1) for roof hatch requirements. (o) Headroom. Every stairway shall have a headroom clearance of not less than 6 feet 8 inches. Such clearances shall be measured vertically from a plane parallel and tangent to the stairway tread nosings to the soffit above at all points. 640 "' 1991 UNIFORM BUILDING CODE 3306-3307 (p) Stairway Identification. Approved stairway identification sighs shall be lo- cated at each floor level in all enclosed stairways in buildings four or more stories in height. The sign shall identify the stairway, indicate whether there is roof access, the floor leyel, and the upper and lower terminus of the stairway. The sign shall be 16cated approximately 5 feet above the floor landing in a position which is readily visible when the door is in the open or closed position. Signs shall comply with re- quirements of U.B.C. Standard No. 33-2. ' Ramps Sec. 3307. (a) General. Except for ramped aisles in assembly rooms, ramps usedas exits shall conform to the provisions 0f thais section. Ramped aisles Within. assembly rooms Shall conform with the provisions in Section 3315. Ramps which are located within an acce?s!ble route 9f travel shall also comply with Chapter 31. '. (b) Width. The width of ramps shall be determined as specified in Section 3303 (b), but shall not be less than 44 inches, except as specified herein. Ramps serving an occupant load of 49 or less~shall not be less than 36 inches in width. · Handrails may project into the required width a distance of 3 I/2 inches from each side ora ramp. Other projections, such as trim and similar decorative features, may project into the required width 1 I/2 inches on each side. (c) Slope. The slope of ramps required by Chapter 31 which are located Within an accessible route of travel shall not be steeper than 1 vertical to 12 horizontal. The slope of other ramps shall not be steeper than I Vertical to 8 horizontal. ~ (d) Landings. Ramps having slopes s~teeper [han 1 vertical to 15 horizontal shall ha3e landings at the top and bottom, and at least one intermediate landing shall be provided for each 5 feet of rise. Top landings and intermediate landings shall have a dime~n measured in the direction of ramp run of not less than 5 feet. Landings at the bottom of ramps shall have a dimension in the direction of ~'amp run of not less than 6 feet. Doors in any position shall not reduce the minimum dimension of the landing to less than 42 inches and shall not reduce the required width by more than 31/~ inches when fully open. :.. When ramp access is provided to comply with ChaPter 31 and a door swings 'over a landing, the landing shall extend at least 24 inches beyond the latch edge of the door, measured parallel to the door in the closed position, and shall have a length parallel to the direction of travel through the doorway of not less than 5 feet. (e) Handrails. Ramps having slopes steeper than fvertical to 15 horizontal shall have handrails as required for stairways, except that intermediate handrails shall not be required. Ramped aisles need not have handrails on sides se~ing fixed seat- ~ng. (f) ConstrUction. Ramps shall be constructed as required for s. tairways. (g) Surface. The surface of ramps shall be roughened or shall be of~lip-resistant materials. (h) Guardrails. Ramps open on one or both sides shall have guardrails as re- quired by Section 1712. - ' ,.' · 641 3308-3309 1991 UNIFORM BUILDING CODE 1991 uNIFORM BUILDING CODE 3309-3310 Horizontal' Exit · ;. '. Sec. 3308. (a) Used as a Required Exit. A horizontal exit ma~, be considered a a required exit when conforming tO the provisions of this chapter. A horizontal exit shall not serve as the only exit from ti portion of a building, and when two or more exits are required, not more Ihan one half of the total number of exits or total exit width may be horizontal exits. (b) Openings. All openings in the two-hour fire-resistive wall which provide a horizontal exit shall be protected by a fire assembly having a fire-protection rating of not less than one and one-half hours. (c) Discharge Areas. A horizontal exit shall lead into a floor area having capac- ity for an occupant load not less than the occupant.load served by such exit. The capacity shall be determined by allowing 3 square feet of net clear floor area for each occupant to be' accommodated therein, not including areas of stairs, elevators and other shafis or courts. In Group I,'Division 1.1-O~cupancies the capacity shall be determined by allowing 15 square feet of net clear floor area per ambulatory oc- cupant and 30 square feet per nonambulatory occupant. The area into which a hori- zontal exit leads shall be provided'with exits adequate tO meet the requirements of this chapter but need not include the added capacity imposed by persons entering it through horizontal exits. StairWay, Ramp and Escalator Enclosures Sec. 3309. (a) General. Interior stairways, ramps or escalators shall be enclosed as specified in this section. EXCEPTIONS: 1. In other than Groups H and I Occupancies, an encl0sure need not be provided for a stairway, ramp or escalator serving only one adjacent floor and not connected with corridors or stairways serving other floors. For enclosure of esca-. lators serving Group B Occupancies, see Section 706. 2. Stairs in Group R, Division 3 Occupancies and stairs within individual dwelling units in Group R, Division I Occupancies need not be enclosed.. 3. Stairs in open parking garages, as defined in Section 709, need not be enclosed. (b) Enclosure Co. nstruction. Enclosure walls shall not be of less than two-hour fire-resistive construction in buildings four or more stories in height or of Types I and II fire-resistive construction and shall not be of less than one-hour fire-resistive construction elsewhere. EXCEPTION: In sprinkler-protected parking garages restricted to the storage of private or pleasure-type motor vehicles, stairway enclosures may be enclosed with glazing meeting the requirements of Section 4306 (g), (h) and (i). .(c) Openings into Enclosures. Openings into exit enclosures other than per- mitted exterior openings shall be limited to those necessary, for exiting from a nor- 'mally occupied space into the enclosure and exiting from the enclosure. Other penetrations into and opening through the exit enclosure are prohibited except for dUctwork and equipment necessary for independent stair pressurization, sprinkler piping, standpipes and electrical conduit.serving the stairway and terminating in a listed box not exceeding 16 square inches in area. Penetrations and communicating openings between adjacent exit enclosures are not permitted regardless of whether the opening is protected. 642 All exit doors in an exit enclosure shall be protected by a fire assembly having a fire-protection rating of not less than one hour where one-hoUr shaft construction is permitted and one and one-half hours where two-hour shaft construction is re- quired. Doors shall be maintained self-closing or shall be automatic closing by ac- tuation of a smoke detector as provided for in Section 4306 (b). The maximum transmitted temperature end point shall not exceed 450°F. above ambient at the end of 30 minutes of the fire exposure specified in U.B.C. Standard No. 43-2. (d) Extent of Enclosure. Stairway and ramp enclosures shall include landings and parts of floors connecting stairway flights and shall also include a corridor on the ground floor leading from the stairway to the exterior of the building. Enclosed corridors or passageways are not required from unenclosed stairways. Every open- ing into the corridor shall comply with the requirements of Section 3309 (c). EXCEPTION: In office buildings classed as a Group B, Division 2 Occupancy, a maximum of 50 pement of the exits may discharge through a street-floor lobby, pro- vided the required exit width is free and unobstructed and the entire street floor is pro-. tected with an automatic sprinkler system. (e) Barrier. A stairway in an exit enclosure shall not continue below the grade level exit unless an approved barrier is provided at the ground-floor level to prevent persons from accidentally continuing into the basement. (f) Use of Space under Stair and Ramp. There shall be no enclosed usable space under stairways or ramps in an exit enclosure, nor shall the open space under such stairways be used for any purpose. · Smokeproof Enclosures Sec. 3310. (a) General. A smokeproof enclosure shall consist of a vestibule'and 'continuous stairway enclosed from the highest point to the lowest point by walls of two-hour fire-resistive construction. There shall be no openings into the stair- way portion of the smokeproof enclosure other than those permitted by the first paragraph of Section 3309 (c). The supporting frame shall be protected as set forth in Table No. 17-A. In buildings with air-conditioning systems or pressure air supply serving more than one story, an approved smoke detector shall be placed in the return-air duct or plenum prior to exhausting from the building or being diluted by outside air. Upon activation, the detector shall cause the return air to exhaust completely from the building without any recirculation through the building. Such devices may be in- stalled in each room or space served by a return-air duct. (b) When Required. In a building having a floor used for human occupancy which is located more than 75 feet above the lowest level of fire dePartment vehicle access, all of the required exits shall be smokeproof enclosures. EXCEPTIONS: 1. For buildings equipped with an automatic sprinkler system throughout in accordance with Section 1807 (c), smok~-proof enclosures may be omitted, provided all enclosed exit stairways are equipped With a barometric dhmp- ered relief opening at the top and the stairway supplied mechanically with sufficient air to discharge a minimum of 2,500 cubic feet per minute through the relief opening while maintaining a minimum positive pressure of 0.15-inch water column in the shaft relative to atmospheric pressure with all doors closed.~Activation of the me- 843 3310 1991 UNIFORM BUILDING CODE chanical equipment shall be initiated by a smoke detector installed outside the stair enclosure and within 5 feet of the.enclosure door. Such equipment shah also be acti- vated by actuation of the automatic sprinkler system.. 2.Enclosures need not be providedlin open parking garages as defined in Section 709. · ~ :... (C) Outlet. A smokeproof enclosure shall exit into a public way or into an exit passageway leading to a public way. The exit passagewaY shall be without other openings, and shall have walls,., floors. . .and ceiling, ·°f two-hour: .~,fire-resistive' ~. con- struction. : (d) Barrier. A stairway in a smokeproof enclosure sl~ail not continue below the grade level unless an approved ba[rier is provided at the ground level to prevent persons from accidentally continuing into the basement. ~ . : : ~: .... (e) Access. Access to stairways in smokeproot~ enclosures shall be by way of a 'vestibule or open exterior exit balcony c.onstruction of noncombustible materials. (f) Smokeproof Enclosure by Natural Ventilatidn 1. Doors. When a vestibule is provided, the door assembly into the Vestibule shall-have a one- and one-half-hour flre-pr0tection rating, and th~ door assembly from the ~estibule to the stairs shall be a smoke- and draft-control'assen~bly haging not less than a 20-minute fire-protection rating. Doors'shall b6 maintained s~lf-closing or shall be automatic closing by actuation of a smoke detector.' ' Whdn access to the stairway is by means of an open exterior exit balcony, the door assembly to the stairway shall have a one- hnd b_ne-half-hour fire-protection rating and shall be maintained gelf-closing or shall be auto.matic closing by actua- tion of a smoke detector. ' 2. Open-air vestibule. The vestibule shall hav~ a minir~ui-6 dimension of 44 in- ches in width and 72 inches in directinn of exit travel. The vestibule shall have a minimum of 16 square feet of oPening in a wall facing an exterior court, yard or public way at least 20 feet in width."' ":'~' '''' "(g) Smokeproof Enclosures by MechaniC:al Ventilation; L.D0br~. The door assembly from the building into the vestibule shall have a one- and one-half-hour fire-protection rating, and the door assembly from'the vestibule to the stairway shall be a smoke- and draft-control assembly having not less than a 20-minute fire-protection rating. The door to the stairways shall be prox;ided with a drop sill or other provision to minimize'the air leakage: Doors shall be maintained ~elf-closing or shall be automatic closing by actWat~on of a smoke detector or ~n the event of a power failure. 2. Vestibule size. Vestibules shall have a minimum dimension o~' 44 inches in width and 72 inches in direction of exit travel." · . 3. VeStibule ventilation~ The v~tibtile Shaii be pro{,ided ¢/itli not less'ihan One ail'change per min(~te, and the exhaust Shall be 150 percent of th6 shppl~. Supply air shall enter and exhaust air shall discharge fron/the vestibble.through separate tightly constructed ducts used'gnly for that purposn. ~upply [i~ shall enter the vesti- bule within 6 inches of the floor level. The top of the exhaust register shall be down from the.top of the smoke trap and shall be entirely within, the smoke trap area. Doors, when in the open Position, shall not obstruct duct openings. Duct openings 644 ~ 1991 UNIFORM BUILDING CODE 3310-3311 may be provided with controlling dampers if needed to meet the design require- ments but are not otherwise required. 4. Smoke trap. The vestibule ceiling shall be at least 20 inches higher than the door opening into the vestibule to serve as a smoke and heat trapand to provide an upward-movin~ air column. The height may be decreased when justified by engi- neering design and field testing. 5. Stair shaft air movement system. The Stair shaft shall be provided with a dampered relief opening at the top and supplied mechanically with sufficient air to discharge a minimum of 2,500 cubic feet per minute through the relief opening while maintaining a minimum positive pressure of 0.05 inch of water column in the shaft relative to atmosphere with all doors closed and a minimum of 0. I O-inch wa- ter column difference between the stair shaft and the vestibule. 6. Operation of ventilating equipment. The activation of the ventilating equip- ment shall be initiated by a smoke detector installed outside'the vestibule door in an approved location. The activation of the closing device on any door shall activate the closing devices on all doors of the smokeproofenclosure at all levels. When the closing device for the stair shaft and vestibule doors is activated by a smoke detec- tor or power failure, the mechanical equipment shall operate at the level5 specified in Subsections 3 and 5. · ~ -' 7. ,Standby 'power. Standby power for mechanical ventilation equipment shall be provided by an approved self-contained generator set to operate.whenever there is a loss of power in the normal house current. The generator shall be in a separate room having a minimum one-hour fire-resistive occupancy separation and shall have a minimum fuel supply adequate to operate the equipment for two hours. See Section 1807 (i) for standby power requirements for high-rise Group B, Division 2 offices and Group R, Division I Occupancies. 8. Acceptance testing. Before the mechanical equipment is accepted by the building official, it shall be tested to confirm that the mechanical equipment is op- erating in compliance with these requirements. ' 9. Emergency lighting. The stair shaft and vestibule shall be provided with emergency lighting. A standby generator which is installed for the smokeproofen- closure mechanical Ventilation equipment may be used for such stair shaft and ves- tibule power supply. See Section 1807 (i) for emergency lighting requirements for high-rise. Group B, Division 2 offices and Group R, Division I Occupancies. Exit Courts Sec. 3311. (a) General. Exit courts shall discharge int~o a public wa~ or exit pas- sageway.' (b) Width. Exit court minimum widths shall be determined in accordance With' provisions of Section 3303 based on the occupant load and such required width shall be unobstructed to a height of 7 feet, except for projections permitted in corri- dors by Section 3305. The width of exit courts shall not be less than 44 inches ex- cept Group R, Division 3 and Group M Occupancies, where the width may be reduced to 36 inches. 645 3311-3314 1991 UNIFORM BUILDING CODE When the width is reduced from any cause, the reduction shall be effected gradu- ally by a guar.drail at least 3 feet in height and making an angle of not more than 30 degrees with the axis of the exit court ....... . , .: (c) Number of Exits. Exit courts shall be provided with exits as determined by Section 3303. . .... :~ ~. : (d) Construction and Openings. When an exit court serving a building or por- tion thereof having an occupant load of 10 or more is less than 10 feet in width, the exit court Walls shall be a minimum of on'-hour fire-re'sistiveconstruction for a distance'of 10 feet above the floor of the courti and all openings therein shall be protected by ·fire assemblies, having a fire-protection rating of not less than three-fourths hour. · : . : · Exit Passageways Sec. 3312. (a) Construction and Openings. The walls 'of exit passageways shall be without openings other than required exits ~nd shall haye Walls, fibers and ceilings of the same period of fire resistahce az required for the walls, floors.and ceil ings of the building served, with a minimum of one-hour. . fire-resistive, construc- tion. Exit openings through the enclosing walls of exit passageways shall be pro: tected by fire assemblies having a thl-ee-fourths-hour fir6-protection rating. (b) Detailed Requirements. Except for constructionand opening protection as specified in Subsection (a) above, exit passageways 5hall comply with the require- ments for corridors as specified in Section 3305.~ Exit Illumination :' sec. 3313. (a) General. Except within individual dwellinl~ units, guest rooms and sleeping rooms, exits shall be illuminated at any time the building is occupied ,with light having intensity of not less.than 1 footcandle at floor level. EXCEPTION: In auditoriums, thea.ters, concert or opera halls and similar as- sembly uses, the illumination at floor level may be reduced during performances to not less than 0.2 footcandle. .'. Fixtures required for exit illumination shall be ~upplied ~fr0m.,separate sources of pow_er where required by Subsection (b). . . (b~.. eparate Sources of Power. The power supply for exit illumination shall normally be provided by the premises' wiring system. In th~ event of its failure] illumination shall be automatically provided from an emergency system for Group I, Divisions 1.1 and 1.2 Occupancies and for all other occupancies where the exit- ing system serves an occupant load of 100 or more. · For high-rise buildings, see Section 1807. For smokeproof enclosures see Sec- tion 3310 (g) 9. Emergency systems shall be supplied from storage batteries or an on-site gener- ator set and the system shall be installed in accordance with the requirements of the Electrical Code. ~ Exit Signs Sec. 3314. (a) Where Required. When t~o or more exits from a story are re- quired by Section 3303, exit signs shall be installed at stai~r enclosure doors, hori- 646 1991 UNIFORM BUILDING CODE '- 3314-~315 zontal exits and other required exits from the story. When~two or more exits are required from a room or area, exit signs shall be installed at the required exits from the room or area and where otherwise necessary to clearly indicate the direction of egress. ' . . :- EXCEPTIONS: 1. Main exterior exit doors which obviouslyand clearly are , . identifiable as exits need not be signed when approved .by the building official. 2. Group R, Division 3, and individual units of Group R, Division ! Occupancies. '.~ ~ 3. Exits from rooms or areas with an occupant load of less than 50 when located ~ .. witl~in a Group I, Division 1. !, 1.2 or 2 Occupancy or a Group E, Division 3 day-care . ,. -occupancy. . . . ' (b) Graphics. The color and design of lettering, arrows and other symbols on exit signs shall be in high contrast with their background. Words on the sign shall be in 'block letters 6 inches in height with a stroke of not less than 3/4 inch. · (c) illumination. Signs shall be internally or externally illuminated bY two elec- tric lamps or shall be of an approved self-luminous type. Whe. n the luminance on the face of an exit sign is from an external source, it shall have an intensity of not less than 5.0 footcandles.from either lamp;.Intema[ly illuminated signs shall pro- vide equivalent luminance. (d) Power SuPPly. Current supply to One of the lamps f6r exit signs shall be pro- vided by the premises' wiring system. Power to the other lamp shall be from stor- age batteries or an on-site generator set and th6 system shall be installed in accordance with the Electrical Code: For high-rise buildings, see SectiOn 1807. (e) Floor-level Exit signs. When exit signs are required by Section 3314 (a), additional approved low-level exit signs which are internally or externally illumi- nated, or self-luminous, shall be provided in all interiorexit corridors serving guest rooms of hotels in Group R, Division I Occupancies. -. ~ The bottom of the sign shall not be less than 6 inches or more than 8 inches above the floor level. For exit doors, the sign shall' be on the door or adjacent to the door with the closest edge of the sign within 4 inches of the door frame. '(f) Amusemen't Building Exit Marking. Approved direction exit marking and exit signs shall be provided. Approved low-level exit signs and directional marking shall be located not more than 8 inches above the walking Surface and at the exit path. Such marking shall be activated in accordance with Section'610 (c). Aisles, . , Sec. 3315. (a) General. Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with Chapter 31. .. .. (b) Width in Occupancies without Fixed Seats. The width of aisles in occu- pancies without fixed seats shall comply with this section. Aisle widths shall be provided in accordance with the following: 1. In areas serving employees only, the minimum aisle width may be 24 inches but not less than the width required by the number of employees served. · 2. In public areas of Group B, Division 2 Occupancies, and in assembly occu- pancies without fixed seats, the minimum clear aisle width shall be 36 inches where ;647 3315, 1991 UNIFORM BUILDING CODE tables, counters, furnishings, merchandise 0r other'sirnilar obstructions are placed on one side of the aisle only and 44 inches when such obstructions are placed on (c) Width in Assembly Occupancies wi{h Fixed Seats. Aisles in assembly oc- cupancies with fixed Seats shall comply with this section. The clear width of aisles shall be based on the number ofoccupants within the portion of the seating areas "served by the aisle.. ~ · ' .... . The clear width of an aisle in inches shall not be less than the occupant 10ad served by the aisle multiplied by 0.3 for aisle~ ~,ith;slopes greater than i vertical to 8 horizontal and not less than 0.2 for aisles with slopes Of I vertical to 8 horizontal or less. in addmon, when the nsc of steps m atsles exceeds 7 ~nches, the msle cle width sh"all be increased by 1 I/4inshes for' eilch 100 occupants br fraction thereof served for each /4 ~nch of riser height above 7 tnches. ' ' Where exiting is possible in tW6 dire~tions~ the width of such aisles shall be Uni- form throughout their length. When aisles cbnverge i0 form a Jingle path 0fe~it travel, the aisle width shall not less than the combined requi/'ed width of the converging aisle. 'beln assembly rooms with fixed seats arranged in rows,'the"clear Width ;f aihes shall not be less than Jet forth ab0k, e or ies~ thafi the folibwingi ' . 48 inches for stairs.having seating on both Sides. :: :. , . .36 inches for stairs having seating on 0ne.side. ., 23 inches between a stair handrail and seating when the aisles are subdivided by the handrail, i;: ~ ~ ;~'.~ , ' '.~ "' , ·42 inches for level or ramped aisles having seating on both sides. 36 inches for level or ramped aisles having seating on one side. , 23 inches between a stair handrail and seating when an aisle does not serve m°re than five rows on one side. ~ "'~:;.': ' (d) Aisle Termination. Aisles shall trrminate at a cross aisle, foyer, doorway or vomitoryl Aisles shall not have a dead end gl'eater than 20 feet in length.: .. EXCEPTION: A longer dead-en~l aisle' is permitted when seats served by the ~ .~' dead-end aisle are not more than 24 seats from another aisle measured along a row of seats having a minimum clear width of 12 inches plus 0.6 inch for each additional seat above seven in a row. Each end ora cross aisle shall terminate at an aisle, foyer, doorway or vomitrry. (e) Ramp Slope. The slope of ramped aisles shall not be more than I vertical~ in 8 horizontal; Ramped aisles shall havea slipZresistant.surface. (f) Aisle Steps. 1. When prohibited. Steps shall not'be used in aisles having a slope of 1 vertical to 8 horizontal or lesS. '~ ~ :"'" .: ' '.' ~" ' ~2.' When required. Aisles with' a:slope steeper than 1.vertical to 8 horizontal shall consist of a series of risers and treads extending across the entire width of the aisle., ':~' ' ''" ~' ~ The height of risers shall not be more thari 7 inches or less than 4 inches and the tread mn shall not be less ·than 11 inches. The riser height shall be uniform within each flight and the tread mn shall be uniform throughout the aisle. Variations in mn 648 1991 UNIFORM BUILDING CODE 3315-3316 or height between adjacent treads or risers shall not exceed 3/16 inch. A contrasting marking stripe or other approved marking shall be 'provided on each tread at the nosing or leading edge such that the location of each tread is readily apparent when viewed in descent. Such stripe shall be a minimum of 1 inch wide and a maximum of 2 inches wide. EXCEPTION: When the slope of aisle steps and the adjoining se~tting area is the same, the riser heights may be increased to a maximum of 9 inches and ma5' be non- :' '~ uniform but only to the extent necessitated by changes in the slope of the adjoining seating area to maintain adequate sightlines. Variations may exceed 3~16 inch be- : tWeen adjacent risers provided the exact location of such variations is identified with a marking stripe on each tread at the nosing or leading edge adjacent to the nonuni- · ' .~ form riser.. The marking ~tripe shall be distinctively different from the contrasting ..... marking stripe. ~, · .~ (g) Handrails. Handrails shall comply with the height, size and shape dimen- sions set forth in Section 3306 (i) and shall haye rounded terminations or bends.. Ramped aisles ha~inga ~iope steeper than 1 vertical to l 5 horizontal and aisle s[airs (tWo Or more adjac6nt steps) shall have handrails located either at the side or within the aisle width. Handrails [nay project into the reqmred m,sle w~dth a d~stance, o 3/2 inches. EXCEPTIONS: 1. Handrails may be omitted on rampe~ aisles having a slope - .. hot greater than 1 vertical in 8 horizontal when fixed seating is fin both sides of the ' aisle. ~ : ; ' ' " ' 2. Handrails may be omitted'when a guardrail is at the side of an aisle which con- ·: forms to the size and shape requirements for handrails. ;-Handrails located within the aisle width_shall be 'discontinuous with gaps or breaks at intervals not to exceed five rows. These gaps or breaks shall have a clear width of not less than 22 inches or more than 36 inches measured horizontally. Such handrails shall have an additional intermediate handrail located.12 inches below the main handrail. Seat SPacing" ' ', Sec. 3316. When seating rows have 14 or less seats, the minimum clear width be- tween rows Shall not, be less than 12 inches measured as'the clear horizontal dis- tance from the back of the row ahead and the nearest pi-ojection Of the'row behind. where'seats are automatic or sblf-i-ising, measurement may be made. with the seats' in the raised position. Where seats are not automatic or self-rising, the minimum ~le~- kvidth sliall be measui'~d with the seat in the down position. The clear width shall be increased as follows:: . (a) For rows of seating served by aisles pr doorways at both ends, ther~ shall be no'mor~ than 100 seats per row and the minimum clear width of 12 inches between rows shall be ificreas~d by' 0.~ inch for 6very additionaI ~ea[ beyond 1,4, but the minimum clear width need not exceed 22 inches. If the aisles are dead ended, see Sectirn 3315 (d) for further'limitations] ' ;' (b) For rows of Seating S~ed by an ais!~ or doorway mum clear width Of 12 inches between rows shall be increased by 0.6 inch for every additional seat beyond seven, but the minimum clear width.need not exceed 22 in- 649 3318 1991 UNIFORM BUILDING CODE "- Foyers and lobbies constructed as required for exit corridors shall not be con- stmed as adjoining or intervening rooms., , . " When the only means of exit from a room is through an adjoining or intervening room, smoke detectors shall be installed throughout the area of the common atmo- · sphere through which the exit must pass. The detectors shall actuate alarms audible in the interior room and shall be connected to the school fire alarm system. EXCEPTIONS: 1. When the aggregate occupant load of the interior room or rooms is 10 or less. . " ': 2. When the enclosures forming interior rooms are less than two thirds of the floor-to-ceiling height and do not exceed 8 feet. ; · .3. Rooms used exglusively for mechanical and public utility service tO the build- ings. (e) Corridors and Exterior Exit Balconies. Corridor walls and ceilings shall be of not less than one-hour fire-re~istive constrUction With openings Protected as required in Section 3305 (h). EXCEPTION: When each room used for instruction has at least one ekit door directly to the exterior at ground lei,61 and when ro6ms used for assembly purposes have at least one half of the required exits directly t6 the exterior ground .level; one-hour tim-resistive construction of corridor.walls and ceilings is not required. Any change in elevation of less than 2 feet in a corridor.or exterior exit balcony shall be by means of ramps. : . · The width of a corridor in a Group E, Division 1 Occupancy' shall be the width required by Section 3303, plus 2 feet, but not less than 6 feet~ EXCEPTION: Whenthenumbe~'ofoccupantsservedis 100orless, the corridor may be 44 inches wide. ; ~ . .~... . . (f) Exit Serving Auditoriums in Group E, Division I Occupancy. An exit serving an auditorium and other rooms need provide only for the capacity of · whichever requires the greater: width if the auditorium is not to be used simulta- neously with the other rooms. : , · (g). Stairs. Each floor above or below the ground floor level shall have not less than two exit stairs and the required exit width shall be equally divided between such stairs, provided that stairs serving an occupant load of [00 or more shall be not less than 5 feet in clear width. , EXCEPTION: This.subsection does not apply to rooms used for maintgnance, ?torage and similar purposes. :, . · ~ i, ~ (h) Doors. The width Of exit doors shall.be sufficient to accommodate the occu- pant load served. . '.'... .. (i) Basement Rooms. Exit stairways fr6m a basement shall open directly to the exterior of the building without entering the first floor corridor. (j) Panic Hardware. Exit doors from rooms having an occupant load of 50 or more and from corridors shall not be provided with a latch or lock unless it is panic hardware.. ., . '.." ,.-~':. :.' . (k) Fences and Gates. School groundi may be fenced and gates therein equipped with locks, provided safe dispersal areas are located not less than 50 feet from the buildings. Dispersal areas shall be sized to provide an area of not less than 652 1991 UNIFORM BUILDING CODE 3318-3320 3 square feet per occupant. Gates shall not be installed across corridors or passage- ways leading to such dispersal areas unless they comply with exit requirements. See Section 3322 for exits from dispersal areas. Group H OccuPancies ' ~ Sec. 3319. Every portion of a Group H Occupancy having a floor area.of 200 square feet or mote shall be served by at leasi two separate exits. EXCEPTION: Group H, Division 4 Occupancies ha~'ing a floor area ofless than . . 1,000 square feet may have one exit. Within GrOup H, Divisions 1,2 and 3 Occupancies, all portions 0fany room shall be within 75 feet of an exit door. Exit doors from a room classified as Group H, ~ Divisions 1,2 al~d 3 Occupancies shall not be provided with a latch or lock unless it t/ is panic hardware. Doors leading to a corridor of fire-resistive construction shall have a minimum '- three-fourths-hour fire-protection rating; shall not have more than 100 square in- ches of wired glass set in steel frames; shall be maintained 'self-closing or shall'be automatic closing as defined in Section 4306 (b); and shall open in the direction.of exit travel. . ~ ' ' Within Group H, Division 7 and within fabrication areas of Group H, Division 6 O&upancies, the distance of travel to an exterior exit door, exit Corridor, horizontal exit, exit passageway or an enclosed stairway shall not exceed 100 feet. Group I Occupancies Se.c. 3320. (a) Exterior Doors. All required.exterior exit doors shall open in the direction of exit travel (b) Minimum Size of Exits. The clear width of exits serving areas occupied or ' used by bed or litter patients shall be such that it will allow ready passage of such equipment, but shall not be less than 44 inches. Other exits shall have a clear width of not less than 32 inches. There shall be no projections into the clear width. (c) Corridors. The minimum clear width of a corrido~ shall be determined as specified in Section 3303 (b), but shall not be less than 44 inches, except that corri- dors serving any area housing ode or more nonambulatory persons shall not be less than 8 feet in width ..... ~ ~ · ~ EXCEPTION: Corridors serving surgical areas of Group I, Division 1.20~cu- pancies shall not be less than six feet in width until reaching an exterior door, enclosed ex t stairway or horizontal exit and shall not pass through ~n adjoining room. Any change in elevation of the floor in a corridor serving nonambulatory per- sons shall be made by means of a ramp. . 'Corridors shall comply with Section 3305 except that in hospitals and nursing homes classified as Group I, Division 1.1 Occupancies the following exceptions '~I apply: 1. Nt/rses' stations including space for doctors' and nurses' charting and com- munications constructed as required for corridors need not be separated, from corri- dors. · 2. Waiting areas and'similar spaces constructed as required for Corridors need not be separated from corridors, provided: · ' : " 653 ~................~,--...-~. Titie 8 General Industry Safety Orders~L No-rE: Authority cited: Section 142.3, Labor Code, Reference: Section 142.3, La- ployers with 10 or fewer employees the plan may be communicated oral- bor Code; and Section 18943(c), Health and Safety Code. ' ly to employees and the employer need not maintain a written plan. HlsroR¥ Nora Authority and reference cited: Section 142.3, Labor Code. 1. Repealer and new section filed 6-20-75; effective thirtieth day thereafter (Reg- l-hsroR¥ islet 75, No. 25). 1. New section 'filed 9-8-81; effective thirtieth day thereafter (Register 81, No. '- 2. Amendment filed 7-16-76; effective thirtieth day thereafter (Register 76, No. 37). 29). 3. Amendment filed 5-25-83; effective thirtieth day thereafter (Register 83, No. , 22). Approved by State Building Standards Commission 1-24--83. § 3221. Fire Prevention Plan. (a) Scope and Apphcation. This section applies to all fire prevention § 32'18. Exits: Group E Occupencios. plans. The fire prevention plan shall be in writing, except as provided in I-hs'roR~ the last sentence of subsection (d)(2) of this section. 1. Repealer filed 6-20--75; effective thirtieth day thereafter (Register 75, No. 25). (b) Elements. The following elements, at a minimum, shall be included in the fire prevention plan: §3219. Maintenance of Exits. (1) Potential fn'e hazards and their proper handling and storage proce- (a) Every required exit shall be maintained free of all obstructions or dures, potential ignition sources (such as welding, smoking and others) impedknents to full instant use in the case of f'u:e or other emergency, and their control procedures, and the type of fine protection equipment or (b) All f'ne protection equipment, materials and assemblies, where re- systems which can control a f'ne involving them; quired, shall be maintained in proper operating condition, and such peri- (2) Names or regular job rifles of those responsible for maintenance of odic inspections and tests shall be made as are necessary to assure this. equipment and systems installed to prevent or control ignitions or fires; Nome: For further guidance sec applicable NFPA Pamphlets. and I-hsroR¥ (3) Names or regular job titles of those responsible for the control of 1.Repealer andnew sectionfiled6-20-75;effectiveth/rtiethdaythereafter(Reg- accumulation of flammable or combustible waste materials. ister 75, No. 25). (c) Housekeeping. The employer shall control accumulations of ram- 2. Amendment filed 9-7-78; effective thirtieth day thereafter (Register 78, No. mable and combustible waste materials and residues so that they do not 36). contribute to a fire emergency. The housekeeping procedures shall be in- § 3220. Emergency Action Plan. cluded in the written fire prevention plan. (a) Scope and Application. This section applies to all emergency ac- (d) Training. . lion plans. The emergency action plan shall be in writing, except as pro- (1) The employer shall apprise employees of the fu:e hazards of the ma- vided in the last sentence of subsection (e)(3) of this'section, and shall terials and processes to which they are exposed· cover those designated actions employers and employees must take to en- (2) The employer shall review with each employee u pon initial assign- sure employee safety from f'ne and other emergencies, ment those parts of the fire prevention plan which the employee must (b) Elements. The following elements, at a minimum, shall be included know to protect the employee in the event of an emergency. The written in the plan: plan shall be kept in the workplace and made available for employee re- (l) Emergency escape procedures and emergency escape route assign- view. For those employers with 10 or fewer employees, the plan may be ments; communicated orally to employees and thc employer need not maintain Procedures to be followed by employees who remain to operate a written plan. critical plant operations before they evacuate; (e) Maintenance. The employer shall regularly and properly maintain, (3) Procedures to account for all employees after emergency evacua- according to established procedur~. s, equipment and systems installed in tion has been completed; the workplace to prevent accidental ignition of combustible materials. (4) Rescue and medical duties for those employees who are to perform No-m: Authority and reference cited: Section 142.3, Labor Code. them: (5) The preferred means of reporting lb'es and other emergencies; and I. New section filed 9-8-81; effective thirtieth day thereafter (Register 81, No. 37). For prior history see Registers 77 No. 20; 76, No. 29; and 75, No. 25. (6) Names or regular job rides of persons or departments who can be contacted for further informationor explanation of duties under the plan. § 3222, Arrangement end DIstance to l::xlt$. (c) Alarm System. (11 The employer shall establish an employee alarm system which (a) Arrangement of Exits. If only two exits are required, they shall be placed a distance apart equal to not less than one-half the length of the complies with Article 165. maximum over~A1 diagonal dimension of the building or area to be served (2) If the employee alarm system is used for alerting f'ne brigade mem- bers, or for other purposes, a distinctive signal for each purpose shall be measured in a straight line between exits. EXCEgnON: ~rhere exit enclosures vxe provided as the required means of egress used. and are interconnected by a corridor confomdng to the requirements of Section (d) Evacuation. The employer shall establish in the emergency action 3326, exit separations may be measured in a direct iine of travel within the exit plan the types of evacuation to be used in emergency circumstances, corridor. Enclosure walls shall be not less than 30 feet apart at any point in a dkect (e) Training. line of measurement. Where three or more exits are required, they shall be ar- ranged a reasonable distance apart so that ff one becomes blocked the others will (1) Before implementing the emergency action plan, the employer be available. (Title 24, Part 2, Section 3302(c).) shall designate and train a sufficient number of persons to assist in the (b) Distance to Exits. The maximum distance of travel from any point safe and orderly emergency evacuation of employees, to an exterior exit door, horizontal exit, exit passageway or an enclosed (2) The employer shall advise each employee of his/her responsibility stairway in a building not equipped with an automatic sprinkler system under the plan at the follow!ng times: throughout shall not exceed 150 feet or 200 feet in a building equipped (A) Initially when the plan is developed, with an automatic sprinkler system throughout. These distances may be (B) Whenever the employee's responsibilities or designated actions increased 100 feet when the last 150 [eet is within a corridor complying under the plan change, and with Section 3326. (C) Whenever the plan is changed.. EXC'ErlION: Ever5' area used mainly for the storage of materials liable to burn, with (3) The employer shall review with each employee upon initial assign- extreme rapidity or from which poisonous fumes or explosions will result upon merit those parts of the plan which the employee must know to protect the exposure to fire, shall have an exit with/n 75 feet oI~ any point in the area where employees may be present. Where automatic sprinkler protection is provided, dis- employee iN the event of an emergency. The written plan shall be kept at lances may be increased to 100 feet. (Title 24, Part 2, Section 2-3302(d) Excep- the workplace and made available for employee review. For those em- tion 1.) Page 545 ...,.~. -~...-§ 6-,J 82 . B !LAYS CALIFORNIA CODE OFREGUL~NS Title 8 4. Change without regulator)' effect deleting Title 2q reference (Register 87, No. shall provide a canopy, hood, or other suitable protection for detection 49). . . equipment requiring protection from the weather. (2) The employer shall locate or otherwise protect detection equip- Article 163. Fixed Fire Extinguishing. merit so that it is protected from mechanical or physical impact which might render it inoperable. Systems--Water-Spray, and Foam-Water (3) The employer shall assure that detectors are supported indepen- Sprinkler Systems dently of their attachment to wires or tubing. (e) Response Time. § 6182. Water-Spray Fixed Systems, Foam-Water (1) Thc employer shall assure that fire detection systems installed for 8prin klor Systems. the purpose of actuating fac extinguishment or suppression systems shall (a) Scope and Application..This Section applies to'all water-spray be designed to operate in time to control or extinguish a fire. fixed extinguishing systems and to all' foam-water sprinkler systems.· (2) Fire detection systems installed for the purpose of employee alarm This Section do~s not apply to automatic sprinkler systems, which are and evacuation shall be designed and installed to provide a warning for covered in Article 159. . emergency action and safe escape of employees. When water-spray frxed systems or foam-Water sprinkler systems are (3) The employer shall not delay alarms or devices initiated by fire de- provided, they shall meet the design requirements of th~ National Fire teeter actuation for more than 30 seconds unless'such delay is necessary Protection Association's (NFPA) standards on '~Water Spray Fixed Sys- for the immediate safety of employees. When such delay is necessary, it terns for Fire Protection" or "Foam-Water Spray Systems," NFPA Nos. shall be addressed in an emergency action plan meeting the requirements' 15-1977 or 16-1974, respectively. The systems.shall also comply with .of Section 3220. '" - ' ' Article 160. (f) Number, Location and Spacing· of Detecting Devices.. (b) General Requirements. (1) The number, spacing and location of fire detectors shall be based (1) The employer shall assure that foam and water spray systems are upon design data obtained from field experience, or tests, engineering designed to be effective in at least controlling fire in:the protected area surveys, the manufacturer's recommendations, or a recognized testing or on protected equipment, laboratory listing. · (2) The employer shall assure that drainage of water spray Systems is NOT~: Authorit7 and reference cited: Section 142.3, Labor Code. directed away from areas where employees are working and that no . H~STOR¥ emergency egress is permitted through the drainage path. 1. New Article 164 (Section 6183) filed 9-8-81; effective thirtieth day thereafter - (Register 81, No. 37). No'~E: Authority and reference cited: Section 142.3, Labor Code. HistoRY 2. Editorial correction of subsection (f)(l) filed 11-9-81; effective thirtieth day thereafter (Register 81, No. 45 ). 1. Repealer of Article 163 (Section 6183 ) and new Article 163 (Section 61821 filed 9-8-81; effective thirtieth day thereafter (Register 81, No. 37). or prior history, 3. Change without regulatory effect deleting Title 24 reference (Register 87, No. · see Register 76, No. 29. 49). 2. Change without regulatory effect deleting Title 24 reference (Register 87, No. 49). Article 165. Employee Alarm Systems Article 164. Fire Detection Systems § 6184. Employee Alarm Systems. · ' '- (a) Scope and Application. § 6183. Fire Detection Systems.. . . . . (1) This Section applies to all emergency employee alarms. This sec- (a) Scope and Application. This Section applies to alt automatic fire tion does not apply to those discharge or supervisor.~ alarms required on' detection systems. . . various fixed extingfishing systems or to supervisory alarms on fhe sup- (b) Installation and Restoration. prcssion, alm'm or de~ection systems unless they are intended to be em- ~ 1) All devices and equipment shall be designed, installed, and main- ployee alarm systems. rained in accordance with this Section and applicable parts of NFPA (2) The requirements in this Section that pertain to maintenance, test- 721978 series and shall be approved for the purpose for which they are ing and inspection shall apply to all local f'me alarm signaling systems intended, used for alerting employees regardless of the other functions of the sys- (2) The employer shall restore all fire detection systems and comps- tern. nents to normal operating condition as promptly as possible after each (3) All pre-discharge employee alarms shall meet the requirements of test or alarm, subsection (b)(1) through (b)(4), (c) and (id)(1) of this Section. (c) Maintenance and Testing. (4) The employee alarm shall be distinctive and recognizable as a sig- (1) The employer shrill maintain all systems in an operable condition nal to evacuate the work area or to perform actions designated under the except during repairs or maintenance, emergency action plan. (2) Fire detectors and fire detection systems shall be tested and ad- (5) All employees shall be made aware of means and methods ofre- justed as often as needed to maintain proper reliability and operating con- porting emergencies. These methods may be but'not limited to manual dition except that factory calibrated detectors need not be adjusted after pull box alarms, public address systems, radio or telephones. When tele- installation, phones are used as a means of reporting an emergency, telephon, e num- (3) Pneumatic and hydraulic operated detection systems installed after hers shall be conspicuously posted nearby. Jul3' 1, 1981, shall be equipped with supervised systems. (·6) The employer shall establish procedures for sounding emergency (4) Servicing, maintenance and testing'of fire detection systems, in- alarms in the workplace. For those employers with 10 or fewer em- eluding cleaning and necessary sensitivity adjustments shall be per- ployees in a particular workplace, direct voice communication is an ac- formed by a trained person knowledgeable in the operations and func- ceptable procedure for sounding the alarm provided all employees can t. ions of the systems, hear the alarm. Such workplaces need not have a back-up system. (5) Fire detectors shall be.cleaned as necessary to assure proper opera- (b)' General Requirements. 'tion. ( 1 ) Where local fire alarm signaling systems are required by these or- (d) Protection of Fire Detectors. ders, they shall meet the design requirements of the National Fire Protec- (1) Fire detection equipment installed outdoors si' in the presence of tion Association's "Standard for the Installation, Maintenance, and Use corrosive atmospheres shall be protected from corrosion. The employer of Local Protective Signaling Systems for Watchman, Fire Alarm and Page 10~4 8 · General Industry Safety Orders, . § 6184 Supe~isory Service," NFPA No. 72A1975 and the requirements of this sec~on. Subchapter 8. Safety Rules for Gold (2) Thc employee alarm system shall provide warning for necessary emergency action as called for in the emergency action plan, or for teac- Dredges tion'time for safe escape of employees from the workplace orthe immedi- I-hs'roa't ate work area, or both. 1. RePealer of Subchapter 8 ( §§ 4300, 4301, 4305, 4310, 4318, 4323-4330, (3) The employee alarm shall be capable of being perceived above am-. 4335-4342, 4344-4351 ) filed 9-14-71; effective thirtieth day thereafter (Res-. blent noise or light levels by all employees in the affected portions of the ister 71, No. 38). workplace. Tactile devices may be used to alert those employees who LAUNDRY SAFETY ORDERS would not otherwise be able to recognize the audible or visual alarm. (Originally Printed 4-20-45) lc) Installation and Restoration. l-hs'roR¥ ( 1 ) The employer shall assure that all devices, components, combina- 1: Repeal of this set of order containing §§ 4599 to 4606, inclusive, was filed tions of devices or systems constructed and installed to comply with this 12-19-49. The orders were. superseded by General Industry Safety Orders. See standard shall be appi'oved. Steam whistles, air horns, strobe lights or Group 6,'Article 67, General Industry Safety Orders. I similkr lighting devices, or tactile devices' meeting the requirements of this Section are considered to meet this requirement for approval. Subchapter 9. Lamp Scaffold and Parallel (2) All employee alarm systems shall be restored to normal operating Safety Orders* condition as prompdy, as possible after each test or alarm. (d) Maintenance and Testing. I-hs'roR¥ (1) All employee alarm systems shall be maintained in operating con- 1. Repealer of Subchapter 9 filed 7-18-66; effective thirtieth day thereafter (Reg- ister 66, No. 23). For former Subchapter 9, see Register 5 and 55, No. 13. dition except when undergoing repairs or maintenance. (2)'A test of the reliability and adequacy of non-supervissd employee * See Subchapter 7, General Industry Safety Orders, Article 3, Section 3247, alarm systems shall be made every two months. A different actuation de- Lamp Scaffold and Parallels. ' ' vice shall be used in each test of a multi-actuation device system so that no individual device is used for two consecutive tests. (3) The employer shall maintain orreplace power Oupplies as often as Subchapter 10. Liquefied Petroleum Gases is necessary to assure a fully operational condition. Back-up means of Safely Orders alarm, such as employee runners or telephones, shall be provided when systems are out of service. (Originally Printed 4-20-45.. Revision Filed 2-15-46) (4) Employee alarm circuitry installed after July 1, 1981, shall be su- HisTOry pervised and provide positive notification to assigned personnel whenev- 1. Repeal of this set of orders, containing Sees. 4900 through 5041, was filed 11-10-58, effective the thirtieth day thereafter. Refer to Subchapter 1, Unfired er a deficiency exists in the system. All supervised employee alarm sys- Pressure Vessel Safety Orders. (For history of former Sections 4900 through terns shall be tested at least annually for reliability and adequacy. 5041, see Register No. 3, Registers 13 No. 3, 19 No. 1, and 55 No. 13.) (5) Servicing, maintenance and testing of employee alarms shall be performed by persons trained in the designed operation and .functions necessary for reliable and safe operations of the system. Subchapter 1 1, Logging-and Sawmill (e) Manual Operation.. - Safety Orders (1) Manually operated actuation devices for use in conjunction with Ed. Note Subchapter 11. Logging and Sawmill Safety Orders, Ed. re- employee alarms shall be unobstructed, conspicuous and readily accessi- numbered as St~bchapter 13 (beginning with Section 6250). ble. MECHANiCAL POWER TRANSMISSION SAFETY ORDERS NOTE: Authority and reference cited: Section 142.3. Labor Code. I"hsro~Y (Originally Printed 4-20-45) 1. New A~ticle 165 (Section 6 ~84) filed 9-8-81; effective thirtieth day thereafter l-hs'ro~ ¥ (Register 81, No. 37L 1. Repeal of this set of orders containing §§ 5500 to 5585, inclusive, was filed 12-19-49. The orders were superseded by General Industry Safety orders. See 2. Editorial correction of subsections lb)(1) and (e)(1) filed 11-9-81; effective Group 6, General Industry Safety orders. thirtieth day thereafter (Register 81, No. 45). 3. Editorial correction of subsections lb) and (d) filed 6-30-82 (Register 82, No. Subchapter 12. iVline Safety Orders 27). 4. Change without regulator3' effect deleting Title 24 reference (Register 87, No. I-hsTog¥ 49). 1. Repealer ofSubchapter 12 (Articles 1-28, 34 §§ 5900 through 6126, no consec- utive) filed 5-8-72 as an emergency; designated effective 5-15-72. Certificate 5. Editorial correction of subsection (e) (1) deleting obsolete Title 24 reference of Compliance included. For prior history, see Register 58, No. 18 and Register (Register 88, No. 9). 71, No. 17. Page 1045 Title 8~. i: 'General Industry Safety § 3251 less than 4 feet 6 inches vertically above the upper surface of lamp sca_f- ExcEvnons: fold or parallel beds.. 1. Mental, penal, or corrective institutions where super¢isory personnel are con- tinually on duty and effective provisions are made to remove occupants in case (4) Hangi'ng or temporary lamp scaffold and parallel bed prefabricaied of £u'e or other emergency. hangers built before the effective date of these orders shall, when physi- 2. Door(s) in,tailed in a manner that will prevent the door from freezing shut. cai conditions permit, be installed to give a bed head clearance at the 3. Cold storage, processing, and manufacturing rooms where temperatm'es are hanger of not less than 6 feet 6 inches, maintained above 32° F or 0° C. (5) Hanging or temporary lamp scaffold and parallel bed prefabricated (Tide 24, Part 2, Section 2-711 ) -hangers when materially repaired or which undergo a major alteration (d) Doors may be padlocked or otherwise securely locked Rom the shall give the same head clearance when installed as is required for pre- outside if the room is equipped with an inside release mechanism which fabricated hangers built after the effective date of these orders, will release the latch and open the dooi when the latch is padlocked or (6) Permanent catwalks and parallels installed on or before the effec- ' (1) There is' posted on the outside of the doors a sign reading: "Do Not tive date of these orders and having a head clearance less than 6 feet 6 in- Lock These Doors Until You Are Positive No One Is Inside," and ches need not be altered to obtain such head clearance. (2) The room is equipped with an electrically operated audible and vis- (e) Inspection and Maintenance. ible signal System which can be actuated from inside the room and be seen (1) Lamp scaffolds and parallels shall be regularly inspected and main- and heard outside the room. Both systems to be on a single control and tained in a safe condition, tested daily. NOTF~ A cold storage space or box is a room used for the preservation of sub- (2) No nail smaller than 8-penny common (or 8-penny box used in stances by con,oiled temperatures. A cold processing or manufacturing room is sufficient number to give the strength afforded by 8-penny common) an enclosed space or room in which products are treated, processed or manufac- shall be used in the construction of lamp ~affolds and parallels, and they tured in temperatures at or less than 32 degrees F or 0 degrees C. shall be full driven or to the first head when dou bls-headed nails are used. (Tide 24, Part 2, Section 2-713) NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, La- Double-headed nails shall not be used in the walking surface, bor Code. (f) Lamp Beds.. HISTOaV All beds used for lamping shah have a minimum width of 30 inches. 1. Amendment of subsection (e) filed 3-2-76; effective thirtieth day thereafter Lamps shall be so installed that a continuous unobstructed walkway will (Register 76, No. 10). be provided. 2. Amendment filed 7-16-76; effective thirtieth day thereafter (Register 76, No. NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, La- 29). bor Code. 3. Amendment of subsection (c) filed 10-18-79; effective thirtieth day thereafter H~STORV (Register 79, No. 42). 1. Amendment and renumbering from Article 14.1 (Sections 3325, 4. Amendmentfiled2-26-85;effectivethiniethdaythereafter(Register85, No. 3325.1-3325.6) filed 2-1-72 as an emergency; designated effective 2-1-72 9). (Register 72, No. 6). 5. Amendment of subsections la), (c) and (d)(2) filed 3-9-87; effective thirtieth day thereafter (Register 87, No.l 1). 2. Certificate of Compliance filed 4-26-72 (Register 72, No. 19). 3. Amendment and renumbering from Article 14.1~.(Sections 3325, § 3250. Gold Storage, Processing and Manufacturing 3325.1-3325.6) filed 6-1-72 as an emergency; designated effective 6-1-72 Room Exits. (Register 72, No. 23). Certificate of Compliance included. Two remotely located exits shall be provided for cold storage, process- 4. Amendment filed 2-26-85; effective thirtieth day therdafter (Register 85, No. ing and manufacturing rooms where the refrigerant coils are located in- 9). side and carry carbon dioxide, Group 2 or Group 3 refrigerant and the coils are subject to collision damage; or where the refi'igerant agent is lo- § 3248. M~hanical Refrigomtion. cated and/or dispersed inside the rooms. These exits ma3, be through yen- Mechanical re~igemfion systems shall be designed, installed, tested, tilated corridors or other ventilated areas which provide unobstructed and and maintained in accordance with Chapters 4, 15, and 16 of the 1982 safe access to a place of safety. Uniform Mechanical Code (UMC). This order shall not apply to cold storage, process[nS and ma~nufactur.- NOTE: The Provisions of this Order are not intended to apply to the use of water ing rooms hating a floor area of less than 200 square feet provided that or air as a refrigerant nor to refrigerating systems installed on railroad cars, motor vehicles, motor-drawn vehicles or on shipboard, an employee wou Id not be required to travel more than 12 feet to an interi- NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, La- or operating exit door. bor Code. (Tide 24, Part 2; Section 2-713) HISTORY NO~: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, La- 1. Amendment filed ;J-16-76; effective thirtieth day thereafter (Register 76, No. bor Code. 29). HISTORY 2. Amendment filed 9-3-76; effective thirtieth day thereafter (Register 76, No. 1.Repealer and new section filed 9-19-75; effective thirtieth day thereafter(Rex- 36). ister 75, No. 38). 3. Editorial correction in subsection (e) (Regisier 77, No. 41 ). 2. Amendment filed 7-16-7~; effective thirtieth day thereafter (Register 76, No. 4. Amendment of Table No. 15-1-C filed 7-26-78; effective thirtieth day there- 29). after (Register 78, No. 30). 3. Amendment filed 2-26-85; effective thi,-~tieth day thereafter (Register 85, No. 9). 5. Amendment filed 2-26-85; effective thirtieth day thereafter (Register 85, No. 4. Amendment filed 3-9-87; effective thirtieth day thereafter (register 87, No. 9). l 1). § 3249: Cold Storage, Processing, and Manufacturing § 3251. Refrigerator Vehicles. Rooms. Every mobile refrigerated compartment shall have at least one door (a) Every cold storage, processing and manufacturing room shall have which can be opened from inside the compartment and such door shall at least one door Which can be opened from the inside except as provided be so located as to provide a safe means of egress. In addition to the above in (d) below, and there shall also be provided and maintained in workable condition a suit- (Title 24, Part 2, Section 2~7.13) able axe, pinch bar or other tool w,.hich will enable a person to escape if (b) Illumination shall be provided kn thc room. This may be either a ' the door should freeze tight. constantly burning lamp without switch control or a lamp controlled by NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, La- bor Code. a switch to be located inside near the door. Ifa switch is used means shall HiSTo}~¥ be provided to indicate its location in the dark, and I. New NOTE filed 2-26-85; effective thirtieth day thereafter (Register 85, No. (c) A firemhn's-type axe shall be kept in the room near the door. 9). Page 555