HomeMy WebLinkAboutAST-REPORT 6/27/2000 California Regional Water Quality C ontrol .Board O Central Valley Region Steven T. Butler, Chair Winston H. Hickox Gray Davis Secretary for Fresno Branch Office Governor Environmental Internet Ad&ess: http://www.swrcb.ca.gov/-rwqcb5 Protection 3614 East Ashlan Avenue, Fresno, California 93726 Phone (559) 445-5116 · FAX (559) 445-5910 27 June 2000 Mr. Tim Ashlock HPS Plumbing 401 34th Street Bakersfield, CA 93301 HPS PLUMBING, 401 34rn STREET, BAKERSFIELD, KERN COUNTY We recently received a referral from' a City of Bakersfield Certified Unified Program Agency inspector regarding aboveground petroleum storage tanks at your facility. A 27 June 2000 telephone conversation with you and a member of our Staff confirmed the presence of one dual compartment tank containing 1,000 gallons of gasoline and 500 gallons of diesel, and one 1,500-gallon gasoline tank. Major provisions of the Aboveground Petroleum Storage Act (Health and Safety Code, §25270), a state law effective 1 January 1990, require the owner or operator of an aboveground petroleum tank facility with a single tank capacity greater than 660 gallons or with a cumulative storage capacity greater than 1,320 gallons to do the following: 1. File a storage statement and submit an appropriate .fee on or before 1 July 1990 and on or before 1 ~July every two years thereafter. 2. Prepare and implement a Spill Prevention COntrol and Countermeasure-(SPCC) plan, except farms, nurseries, logging sites, or construction sites. 3. Establish a monitoring program for the tank(s) if the appropriate Regional Water Quality Control Board, upon inspection, has determined that discharge from the aboveground tank facility will affec[ waters of the state or sensitive ecosystems. A storage statement form and information about the Aboveground Petroleum Storage Act are enclosed. By 31 July 2000, please submit documentation to our Fresno Branch Office that you have submitted your storage statement and fee to the State Water Resources Control Board in Sacramento. By 29 September 2000, please submit a copy of the SPCC plan that will be 'maintained and implemented at your facility. The SPCC plan needs to be prepared in accordance with Part 112 of Title 40, Code of Federal Regulations. California Environmental Protection Agency  Recycled Paper Mr. Tim Ashlock - 2 - 27 June 2000 Guidance for the preparation of a SPCC plan, as developed by the U.S. Environmental Protection Agency, is enclosed to assist you. If we may be of further help or if you have any questions regarding the Aboveground Petroleum Storage Act, please call Richard C. Stewart at (559) 488-4391. RUSSELL W. WAIJJS Senior Engineer RCE No. 43140 RCS:rcs .. Enclosures cc: Mr. Steve Underwood, City of Bakersfield Office of Environmental Services, Bakersfield Aon Risk Services Insured Group Maintenance America Corp. I RECEIVED HPS Plumbing Services, Inc. 401 34th Street [~~l Bakersfield, CA 93301 IS¥: J To: Certificate Holder City of Bakersfield Important: If the certificate holder is an ADDITIONAL INSURED, the policy(les) must be endorsed. A statement on this certificate does not confer rights to the certificate holder in lieu of Office of Environmental Services such endorsement(s). If SUBROGATION IS WAIVED, subject to the terms and conditions of the 1715 Chester Avenue policy, certain policies may require an endorsement. A statement on this certificate does not Bakersfield, CA 93304 confer rights to the certificate holder in lieu of such endorsement. Disclaimer: The Cert. of Ins. does not constitute a contract between the issuing insurer(s), authorized representative or producer, and the cert. holder, nor does it affirmatively or negatively amend, extend or alter the coverage afforded by the policies listed thereon. The ~olicies of insurance listed below have been issued to the Insured named above for the policy period indicated, notwithstanding any requirement, term, or condition of any contract or other document with respect to which this certificate may be issued or may pertain. The insurance._aff~o~rded by three p__olicies described herein is subject to all the terms, exclu~io~ a_nd conditio~of, su_u._ch ---?olicies:-Izitnits s/town' tna)/Yta-ve bee~' red~tced -b} ; [~rild'clain~7 -- Co Type of Insurance Policy Nnmber Policy Policy Policy Limits/Values Policy Effective Expiration A General Liability Each Occurrence $ 1,000,000 [5~]Commercial General Liability GL194316504 8-1-99 8-1-00 Fire Damage-Any one Fire $ 1,000,000 [-IClaims Made [5~]Occurrence Med. Exp.-Any one Person $ 5,000 [] Personal & Adv. Injury $ 1,000,000 [] General Aggregate $ 2,000,000 General Agg. Limit Applies Per: Products-Comp/Op Agg. $ 2,000,000 []Policy [5~]Project []Location Policy Aggregate $ 50,000,000 A Automobile Liability Combined Single Limit $ 1,000,000 [5~lAny Auto BUA194316521 8-1-99 8-1-00 Bodily Injury-per person $ []All Owned Autos (other States) Bodily Injury-per accident $ []Scheduled Autos Property Damage-per acc. $ [5~Hired Autos BUA194316518 (TX) [5~Non-Owned Autos [~Auto Physical Damage Deductible/Coil & Other than $ 1,000 Collision A Excess Liability Each Occurrence $ 25,000,000 [~]Occurrence []Claims-Made M194316535 8-1-99 8-1-00 Aggregate $ 25,000,000 Prod/Comp eps Agg. $ 25,000,000 [--[Deductible $ [~Retention $10,000 A Workers Compensation and WC194316471 [~WC Statutory Limits []Other Employers Liability (All Other States) 8-1-99 8-1-00 E.L. Each Accident $ 1,000,000 g - WC194316499 E.L. Disease-Ea Employee $ 1,000,000 (Oregon) E.L. Disease-Policy Limit $ 1,000,000 Insurance Compan(ies): A ContInental Casunlty Company B. Continental Transportation Company Description of Operations/Locations/Vehicles/Exclnsions Added by Endorsement/Special Provisions: Certificate Holder is listed as Additional Insured where required by written contract under GL/AL/UMB. The insurance afforded to the A.I. as described in this Certificate of Insurance (COl) for work performed by the Named Insured, is primary and non-conlributory to any similar coverage maintained by the A.I. A Waiver of Subrogation is issued in favor of Certificate Holder where required by written contract under the GL/AL/UMB/WC. As regards Workers Compensation for monopolistic States of NV, ND, OH, WA, WV, and WY, Certificates of Insurance will be issued by the appropriate government authorities. Certificate Holder is Loss Payee as their interest may appear for Auto Physical Damage coverage. Cancellation: This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend, extend or alter the coverage afforded by the policy(les) shown hereon. Should any of the above described policies be canceled before the expiration date thereof, this agency, on behalf of the issuing company (les), will endeavor to mail 30* days written notice to the above named certificate holder, but failure to mail such notice shall impose no obligation or liability of any kind upon the company (les) or this agency. Aon Risk Services of Texas, Inc. *except 10 days notice for non-payment of premium ~,,~._~~ Date: July 25, 1999 By: Authorized Representative, Timothy F. Kelly Aon Risk Services, of Texas, Inc. 2000 Bering Drive, Suite 900 Houston, Texas 77057-3790 tel (713)430-6000 fax:(713)430-6520 F:\CLIENTS\Aon\GMAC\Policies\HPS Plumbing\AONNRG2000. doc CITY OF BAKERSFIELD OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (805) 326-3979 APPLICATION TO INSTALL AND/OR REMOVE ABOVE GROUND STORAGE TANK(S) In conformity with provisions of pertinent ordinances, codes and/or regulations, permission is hereby granted to: Name of Company Address to display, store, install, use, operate, sell or handle materials or process involving or creating conditions deemed hazardous to life or property as follows: ,ubject to the provisions and/or lirrfitations as proviae, and/or regulations shall void this permit. Permit Denied ,~,-.2..- Date ., Applicant Name (Print) ....... Appl~cant Signature THIS AFPLICATION ~ECOME$ A P)",RMIT W~'EN API)RO~D CITY OF BAKERSFIELD OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (805) 326-3979 APPLICATION TO INSTALL AND/OR REMOVE ABOVE GROUND STORAGE TANK(S) In conformity with provisions ofpertinem ordinances, codes and/or regulations, permission is hereby granted to: Name of Company Address to display, store, install, use, operate, sell or handle materials or process involving or creating conditions deemed hazardous to life or property as follows: subject to the provisions and/or limitations as provided, Violation of pertinent ordinates, codes and/or regulations shall void this permit. Permit Denied ,~- Date Applicant Name (print) Applicator Signature THIS APPLICATION BECOMES A PERMIT WHEN APPROVED a ~roupMAC. company P.O. BOX 6386. BAKERSFIELD, CA 93386 /¢~ "~'i'i' ' ?'~~ (805) 324-2121 · FAX (805) 322-5648 .... ' ' ' ';7'*~. CA LIC 751912 · NV LIC 0039424 ]anuaw 8, t999 Steve Understood Bakersfield City Fire Department Environmental Services 171 fi Chester Ave. Bakersfield, CA 93301 RE~ Gasoline Tanks at 401 34th Street Dear Mr. Underwood, Attached is a site plan showing the aboveground fuel tank locations. It is marked indicating which one is a split tank. Please use this site plan and the enclosed information to do your preliminary review for issuing a permit. Additionally you had asked for some additional information. The information is listed below: 1. The island was poured by Hauser Construction. 2. The island was poured 11-10-97. 3. The ballards are imbedded 3'. Also included are the specifications for the two tanks. I will bring you the check for $138.00, and complete the application when you call me to say that you are ready for me. I do want to remind you that I will be on vacation from January 15, 1999 through January 22, 1999. Sincerely, HPS Plumbing Services, Inc. Tim Ashlock "A Tradition of Excellence Since 1959" 1-12-1999 2:24PM FROM WHOLESALE FUELS 80B32294~5 ~10'-16" I ~ULTI-HAZARD 4 HOUR FIRE RATED FULLY 2"OS'~t USTEO OOUSl[ wALL TAHK ASSEUBLY PO2" 2''°~ ~ ~ e" Thick, Light.eight. ImpaCt ~rojecti~c ~ 10"-1~' -- '~' ~ Integra~ SuppOrtS ~n¢ Seilmi~ Re~troint~ TOP VIEW - [NTIR{ TANK ASSE{BLY IS USTEO AS AN · Propde{ory ~e~i~n ~d in{ulatlng  TANK for-F~M~ASL[-ond-COMSUS?I~L[ the requirements ef ~nif~m Fire Cod. LIQUIDS- UL 2085, PROTECTED SW~ Te~t Standard k-~-r-1e for Fire r ~if~ ~1~[ COD( STANOARD A-~-F-I,* ' ~ec;~'y engineered construction G L~el Gogc · Outer steel ~O~k p~otects thc 4~sul~t~on b~li$~[C ;mpoct in o~o~donce V N~mot Vent from t~ horm}ul effects of Fha ~eother Sccti~ 77.203(d)(2) et the Uniform Fire PEV PriOry truer. V~t and from dgr~0ge durlnq normal u~. Outer ~teel tank is protecced /rom UT ~}tor Tube * L~gh~eigh{ desi~ makes deli~y element~ with a high porT--anco induoir~al S Spo~e and installoUon much ~osi~r thon epoxy and urcthon~ ¢oatlng s~tom, normal weight concrete tank~, * ~tegrol supports provide 4" qround · Out~ :loci tank cepocity 4S ~eoter clearance grid se;~c ~nchor[n~ capability, primary took. ~e monitor tube all~s ph~icat ~IN/MU~ O~TER TANK DI~IONS SUPPOE~ AFPROX, · Dispensing & Storage: ' WIDTH, ~asoline. Dictel, Ethanol, MOD~ NO. CAPACI~ ALICe, H ~i~, ~ ~N~. L ~ .... W~IGHT IAethonol, Jet Fuels, Lube Oi~ 0;I, Sol~ents. An1;-feeeze MHR-D-~ 500 ...... 4' B" 6', ~;" 6' 1" 6' 2" 5.650 . Optional fuel dispcn~ng a~d ~as~c ~H~-O-500D 2~0/250 4' 6" 8' 0" 6' i" 6' 2" 5,8~ equipment pa~kog~* ~-D-I~O ~.OOO 4' 8" 6' 0' ]]' 2" : 8' ~" g.250 · O~tlenal Ut Lis~ ~p;ll ~entoinment ~HR-D-10000 ' 500/500 4' 6" 6' 0'"' 11' 1."_ 6~ 2" g,~0O $~tem ovoiloble, BHR-~-IQOOS2 750/25~ 4' 6" 6' 0" 11' 1" _..6' 2" 9,~00 · 0ptlonol access pleUgrm ~HR-D-1$00,,. 'liS00 4' 6" 8' ~" ,,11' 1" 8' 4" 111600 ~ Meets re~ulrements o[ NFPA 50 l~ above ~R-DTI50~ 75~/750 4' 6" 8' 3" t~',,~" B' 4" 1~.600 9r~na ~;orog~ aHR-O-1500S2 1.000/500 4' 6" 8' 3" ]3' ~" ~, 4,, t2,300 - Bectro~ic menitorin~ capability, MHR-B-2B00 2 000 5' 7" 8:"~" 11' 1"" 8' 4" i2.~0 · E~v~enmento, y sore. MHR-D-2OO0~ t,000/1,000 5' 7" 8' 3" 11' 1" ...L B' 4" ' 12,800 · No U~crgroune storage Ionk MHR-O-20~OS2 1,5D0/5~, 5' 7" 8',3" 11' 1" I ~' 4" 13,60~,, · Desired to withstand nOlufol d;sostcr~ includln~ earthquakes and SUPERVAULT MH MODEL D , kaown ~ UFC ~tandard 79-7, I SU ER WA UL T TgUSCO TANK INC. I ULTI- gO PBOT,~CTED TANK ( 8 0 0 ) 8 0 0 -- TAN K J ~.: .~,~,o..0.: i ~.,.,o. ~== "I D~WING J 4tlzlge o size 9e ~ ...... I ../ I .- '1-12-1999 2:2BPM FROM WHOLESALE FUELS 80532294¢5 y OUTLIN£ Of TANK HE)L[ A 1/2" ~xc~^N$~O~ R~OOMM~NDE~. ' .......... ~ ....... · rANK SUPPORTS, ANCHOR PLATES, AND ANCHOR BOLTS MEET THE REQUIREMENTS OF THE UN~FORM 8UI~OINO C0¢[ FOUNOATION ~OAO% ~NO SEISMlC ZONE 4. FOR THE ANCHOR BOLT SIZE AND QUANTITY $¢~CIFt~O fH[ MINIMMM CONCEal6 STRENGTH AT 28 DAYS MUST BE 3000 psi OR 9REATER. I¢ lANK ANCHORAGE IS REQUIRED, THE TANK 'SHALL BE INSTALLED ON CONCEE?E PADS AS SHO~ ON ORAWIN~ ~.1~ AND ACOORDIN~ TO THIS ORAWIMO. ALL SPECIFIED ~OLT DIAMETERS AND EMBEDMENT DEPTHS ARE FOR POST-INSTALI_E~ ITW-~AM%ET / REDHEAD TRUBOLT WEDGE A~CHORS, MAXIMUM ~,BEO~NT DEPTH MU~? NOT EXCEED THE VALUE SHOWN · 1/4". MINIMUM EDGE D~STANCE IS 6 BOLT ~IAMETERS. ~HR'250 5~ A9 '4~ 1 ~A ~/~ ....... 2 tfl n/o 6 VHR-500 44 71 65 I U, T/~ 2 ~,5 n~o 10 ~/~ UHR-1000 88 71 ~ 65 1 ~/~ ~/e 2 J/, n/o .~0 ~/~ HOLE UHR-IO0~ B8 71 6~, 1 I/~ 5/~ 2 ~/~ ' n/O tO ]~. ~PLUS MHR-1500D 88 9Z 9t 2 5/le sic , ,2,,~A 7 14 12 U~R-~50052 S8 97 91 2 sA~ s/~ 2 ~A 7 ~/~ ~2 ~6 ~HR-20~B ~ 97 gl 2 5A~, 5ts 2 ~h ~ V~ 12 ~6 ~NR~2000S2 88 97 91 ~':~ ~/,e.~. s/e 2~/4 7Vt 12 V~ S PPORTS S IS IC ANCHORAGE REQUIREMENTS FOR TYPE 2 SUPERVA ULT MH RECTANGU R TANKS TRUSCO TANK INC. .~u~r~-~ZS~ ~T~, 1-12-1999 2:26PH FROM. WHOLESALE FUELS Longitudinal Steel -- Tronsverse Steel typical of bot~ SlObS---~%~[1 typicol of both slobs CONCRETE: Reinforced portlond cement concrete och[evi~ strength of ~000 REINFDRCIN0 STC[L; All raj*forcing steel 2" m~nlmum shoH be deformed boes Traneverse ~ J ~tcel obo~ grode to ASTM A615 Grade J ~ ,,, size= 0~ auont~t~es ~hown ' ~ ~" clc0r~ J [ ~4" minimum o~ e~u0[. Minimum boit ~ . ~ 5" cleor ~ ~ below grade q~ontJ[g, o~d plocement sholl " ~ Longitudinal Oc ~mr drow;ng No. S.136. Steel ...... S~S SIZES ' R{INFoECiN~ STE~L ....... 1. FOUNDATION SIZE5 SHOWN HERE ARE D~S~ON[D TO LIMIT ~ODEL NO. OAL (¢i dl~i,., ;. i..h.4 LONCtTUDINGAL TRANSVERSE THE MAXIMUM SOLL L W t Bar Size Qt~. Bar SiZe ~, ~e~j PRESSURE TO UNOER 1000 PSF. MHE-250 66 ..... ~,260 6 ~4 5 ' ~4 18" MHR-500 56 12 84 6 ,~4 7 ~4 18" 2, THE FOUNOATION SNALL 8~ INSTALL¢O , AS SHOWN A~OVE, tr ,~-500D 56 12 84 L~.,. ~4 7 ~4 18" SLA~ IS USED. A FOUNOA~ON MHR-IO00 104 16 84 6 ~4 7 ~4 '¥8" D~SIGN FROM A LICENS~O MH~-I O00D 105 17 84 6 ~4 7 ~4 18" SHOULD BE USED. MHR-1000S2 ~ 05 17 84 6 ~4 7 ~4 18" MNR-1500 t05 15 108 6 ~4 9 ~4 18" ~. THE SLABS MAY BE EXTENDED ....... B6YONO TH6 TANK FACE wITHOUT MHR-1500g 103 .~5 108 6 #4 9 ~4 18" CNANGINO THE REQUfREMENT5 FOR MHR~,1500S2 105 15 108, 6 ~4 9 ~ 18" SLAB YM~O~NESS OR ~EI~rOROEMENT MER-20OO 109 j 21 108 6 ~4 9 ~4 18" FOR LOADS ~MPOSEO BY THE TANK MHR-2OOOD I09 '"~1 108 6 .... ~4 9 ~4 ~8" AND IfS CONTENTS. MH~-200OS2 109~ 21 108 6 ~4 9 ¢4 .'~ 8~ 4, THESE DERAILS AR[ FOR ' CAST- IN-PLACE SLAB~ ONLY AND 90 NOT APPLY TO PRECAS1 SLABS, MINIMUM FOUNDATION REQUIREMENTS FOR SUPERVA ULT MH RECTANGU R TANKS TRUSCO T~K INC. suP~RVAULT® MH MULTI-HAZARD RATED, P~0TECTED