Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
UNDERGROUND TANK FILE #1
Kern High School Distrint TRANSPORTATIk---j {'{?//'~'~ "~ ~ Jim Shearer Supervisor Vehicle Maintenance i~,,,]1 E. BelleTerroce#C Bakersfield,CA ~,_~7 (805) 631-3201 (805) 398-7042 (FAX) Kern High School Distr~'-~ Clem Williams Operations Supervisor Transportation ~..,,,D1 E. BelleTerrace #C Bakersfield,CA '~7 (805) 631-3199 (805) 398-7042 (FAX)v Hazardous Materials/Hazardous Waste Unified Permit . CONDITIONS OF PERMIT ON REVERSE SIDE This ~ermit is issued for the followinp: El Hazardous Materials Plan [] Underground Storage of Hazardous Materials Permit ID #:: 015-000-001038 [] Risk Management Program KERN HIGH SCHOOL DIST [] Hazardous Waste On-Site Treatment LOCATION: 3701 E BELLE TERRACE C ~, 4.~'.. , ~.'. · ~ ... ~ · TANK HAZARDOUS' ~.;,,,,.,.~ CAP.,:~,~. ~ (¢i;'i~,, DISPENSER"PANSMONITORING 015~000-001038-0001 WASTE OIL ? :i: ~i::;.~,:~ ':~.~:~::~:~' .... :'~'~:~-~i?~0~ 015-000-001038-0002 DIESEL #2 ~ .~ ,~' '~.;;:;~.:~!2;~Tod ~:~ ' :! i ' ;;'~"~,.~,~,~.~, ~: ~;::~;~,~ · -'~ 015-000-001038-0003 GASOLINE UNLEaDeD :~; .-.t..? ,~.~ · ~4,.':,....-,..., .. Issued ~y: Bakersfie,d Fire Depa~ment OFFIC~ OF ~N~R ONMENTAL SER VICES 1715 Chester Ave., 3rd Floor Approved by: nLr:~aoa~erst~e~u, CA 93301 OmceorEv~S~ic~ Issue ~te r Voice (661) 326-3979 F~ (661) 326-0576 Expiation Date: Permil Operate Hazardous Materials/Hazardous Waste Unified Permit ' CONDITIONS OF PERMIT ON REVERSE SIDE ........ ,,~,.~,,,,~,~,~,~,~,~,~,,,,~,~,~,~,~ .......... This permit is issued for the following: . LPT G~VITY CLM ,0013 GASOLINE UNLEADED 12,00'~;0~ G~:~';~ ~ ?','"'= ? Issu~ by: 1715 CheAer Ave., 3rd Floor B~e~fiel~ CA ~ ~ ' ~ Voice (805)~26-~979 F~ (80S)~2,~S76 Expiration ~: dun~ ~O~ ~OOO City of Bakersfield Office of Environmental Services 1715 Chester Ave., Suite 300 Bakersfield, California 93301 (805) 326-3979 : An upgrade compliance certificate has been issued in connection with the operating permit for the facility indicated below. The certificate number on this facsimile matches the number on the certificate displayed at the facility. Instructions to the issuing agency: Use the space below to enter the following information in the format of your choice: name of owner; name of operator; name of facility; street address, city, and zip code of facility; facility identification number (t¥om Form A); name of issuing agency; and date of issue. Other identifying information may be added as deemed necessary by the local agency. This permit is issued on this 2na day of November, 1998 to: KERN HIGH SCHOOL DIST TRANS DEPT Permit #015-021-001038 3701 E Belle Terrace C Bakersfield, California 93309 ~, DISTRICT SUPPORT FACILITY' KE'RN HIGH SCHOOL DISTRICT SITE PLAN BAKERSFIELD, CA }-'.ERN HIGH SCHOOL DST 3701 E.BELLE TERRACE B~}(ERSF I ELD 661 -827-:3199 DEC 15.. 200',3 2:06 P'P1 S'Y'STEP1 S;TaTLIS REP,:)~T aLL FUNCTIObIS I'~L I I',lt/ENTORY REPORT T 1 :UNLEADED VOLUME : 1 10~6 G~L~ IJLL~GE = q67 G~LS '~l]~k~ ULLAGE= 0 G~LS TC VOLUNE = 11007 HEIGHT = 96.EI1 INCHES 1.4ATER VOL = 0 F'"' t4~TER = 0.00 iNCHES TEMP = 66.3 DEG T 2: D 1ESEL VOLUME = 4826 IJLLRGE = 7197 ,:gAL~ 9-*" 5994 U,o ULLAGE= ,:gALS TC VOLUME = 4?98 HEIGHT = 46.85 IN_HE~ bJgTER VOL = 19. TEPlP = 7:3.0 '~G 2' S: b,IASTE O I L VOLUME = 822 GaLS ULLAGE = 1192 GALS 90~.:~: ULLAGE= 990 GALS TC VOLUME = 816 HEIGHT = 26.52 INCHE~ bJATER VOL = 17 GALS bJATER = 1.8~ INCHES TEMP' = 75.9 DEG F -~ Bakersfield Fire Dept. UNIFIED PROGRAM []~PECTION CHECKLIST Enironmenta] Se~ces ~' ............................ ,',, ', ....... ' ' 1715 Chester Ave SECTION 1 Business Plan and Inventory Program Bakersfield, CA 93301 Tel: (661}326-3979 FACILITY NAME [INSPECTION DATE I INSPECTION TIME ADDRESS / IPHORE N(~. [No. of Employees Section 1' Business Plan and Inven~ P~mm ~ Routine ~Combin~ ~ Joint Agency ~ Multi-Agency ~ Complaint ~ Re-inspection C V /c=co~¢~ OPE~TION COMMENTS ~ V=Violation ~PPROPRIATE PERMIT ON HAND CORRECT OCCUPANCY VERIFICATION OF INVENTORY ~ VERIFICATION OF LOCATION ~ PROPER SEGREGATION OF MATERIAL ~ ~ VERIFICATION OF MSDS AVAI~BILI~E ~ VERIFICATION OF HAT MAT TRAINING VERIFICATION OF ABATEMENT SUPPLIES AND PR~EDURES ~ EMERGENCY PROCEDURES ADEQUATE ANY H~ARDOUS WASTE ON SITE?; ~ YES ~No EXPLAIN: QUESTION.~ EGARDIN~ THIS INSPECTION? PLEASE CALL US AT (661) 326-3979 ...... ............................... nspector Badge No.,. ~T~i~-~'a~* ........... While - Environmental Services Yellow - Slation Copy Pink - Business Copy CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3ra Floor, Bakersfield, CA 93301 FACILITY NAME i~.Pt.q .O "'[m0t~ Dt~r~ INSPECTION DATE Section 2: Underground Storage Tanks Program [] Routine I~]'Uombined 1~ Joint Agency [] Multi-Agency [] Complaint [] Re-inspection Type of Tank 0tO_l~_5 Number of Tanks Type of Monitoring dctvx Type of Piping OPERATION C V COMMENTS Proper tank data on file Proper owner/operator data on file Permit tees current Certification of Financial Responsibility ~.~,,/ Monitoring record adequate and current Maintenance records adequate and current Failure to correct prior UST violations Has there been an unauthorized release? Yes No k....//_ Section 3: Aboveground Storage Tanks Program TANK SIZE(S) AGGREGATE CAPACITY Type of Tank Number of Tanks OPERATION Y N COMMENTS SPCC available SPCC on file with OES Adequate secondary protection Proper tank placarding/labeling Is tank used to dispense MVF? I f yes, Does tank have overfill/overspill protection? C=Compliance V=Violation Y--Yes N--NO Inspector: ,,~'~j _/~/~'/t~l/~ t~ ~ Office of Environmental Services (805) 326-3979 Business Site Responsible Party White - Env. Svcs. Pink - Business Copy ~ 7-23-2803 8:~IAM DALVALLEY EQUIP 1661 CITY OF BAKERSFIELD OFFICE OF'ENVIRONMENTAL SERVI?g$ :" 1715 Chester Ave., Bakersfield, CA (805) 326 3979 PERMIT APPLICATION TO CONSTRUCT/MODIFY UNDERGROUND STORAGE TANK .TYPE. OF APt~CATION (CHECK) [~NEWFACILITY" [ ]MODIFICATION OF FACILITY [ ~qEWTANKINSTALt~TIONATEXISTINGFACR,ITY STARTING DATE PROPOSED COMPEL:~ON DATE. TYP£OFBUSINF, S$ -'2'~.,~,/· ~,.-:~'/>~. ....... APN# ~ ' '_ · ,.-~, ...... ~._ CONTRACTOR ,'",~,--~z~//~'~ ~i,m, (~ALIC]~2~PSENO. PHONE NO.' ~ ~/. ~ 7. ~- ~ ~ ~ ! BAKERSFIELD CITY BUS;D4ESS LICENSi~ ;NO. · o)z. _ .-'~',_~ ;.../*~ .... , ,, . DEPTH TO OROUND WATER ~ TYPE F.,X~I'F..D AT NO. Ol~ TANKS TO Bt~ ~STALL~D ~'~ ~ TI-~Y FOR MOTOR FUEL " .YES. NO SECTtON ~,o~MoTon rANK NO. VOLUME UI, n.]~ED P.F_.GUI.AR PREM]UM DIP.~EL AVIATION , SECTIO~ _FOR NON MO,,~II_FUEL STOJ~GE TAN'KS TA.N~ NO. VOLU~E CHEMICAL STO~ED CA~ NO. CH]~M~CAL PREV]OU'~LY STORIED (NO BRAND NA}~) (]~ KNOWN) 7-28-2083 9:18AF4 CALVALLEY EQUIP ,1GG132S2S29w P. 2 · t,,~t s~.,B_Z'- ~ ~, -. CITY OF BAKERSFIELD . OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (805) 326=3979 PKB~IT APPLICATION TO CONSTRUCT/MODIFY UNDERGROUND STORAGE TANK ~t~,z OF_Ae~CAT~O~. (c~n~CK) · ( ]NEWFACILfrY ( ]MODIFICATIOlqOFFACILITY [ JNEWTANKINSTALLATiOlqATF. XISTINOFACILrrY START~O DATE PROI~3ED COMPLI/TIOlq DATS. ~VATER TO FACILITY PROVIDED BY ~ . ~'z// . k-_F.,~ ~-~'/z_. .. DF, FrH TO OROOND WATF,~ ....... r , S0R, TYPE EXi~F-cTI/D AT srm I~O. OFTANKSTOBI~INST~t%m~' ,~2~ ... AKE THEY FOR MOTOR FUEL ".... Y~. NO SPILL ~P, EV]mTION CON'mOL AND Cc/)m-~ MZAStrI~ PLAN O~FmZ . ..~" W,S ._ '. NO TANK NO. VOLUME UNLEADED R.EGIILAR PREMIUM' DIF.,qF, L AVIATIO~ . ~J~CTION FOR ~O,N MOTOR ~i~L -~TORAGZ TA.~ ~O. voLtn~ c~ SrOar~V CAS ~O. C~CAt, mWV~O~LY ~O B~Oh',ID NAI~) ~ IQ4OWN) ': 8-20-21~0@ 4: C, gPM CALVALLEY EQUIP 1 .. ':" 'i: v . ~'. '}L .:.':~ : CITY O~ BA~~IEBD , OFFICE OF EN~RO~NTAL 17.15 Chester Ave., B~emfield, CA (661)326-39? APPLICATION TO PE~O~ FUEL MONITORING. CERT~ICATION : ' OW~S Na~ DO~ F~C~Y ~VB DISP~R ~S? ~S ~ NO NAME OF TF_.,STINO COMPANY' ~,,/"-[,/~/1~ ~,~, t.,/PI,'14el, Cl- ~, . :~. .. : ..... r.~. ..:.,... CONTRACTORSLICENSR# _'7f/'~//7/~ _~.. N/~Z .. ': ' '" ''(''=; ":'" ':', NAMB & PHONE NUIVIB~ OF CONTACT PERSON ~/~'.,t~f. e : :,,,,~ ~ - ,, .... . ] :. .~,.,:',:;,.;.:~.,.,:....,,.~. · ~: : ,, '~'? t. '::' ~.-'.: ,'." DA'I~ & ~ WEST. IS TO BE ~ONDUC"I~D _: ""7~.5 - ~_f .... , '. ,'...,.!! · . , ~ .. ,. .,..., ~¢.,,'~ : ~... · ' ." ". . : ·., ..~ !,.,i~.,.,,.~, .., ;, · · ~-.-~ ~ -~L..~;~:~.:... '::._ ::,, ..., .,.:, .'-: :':;~:i< :.~.:? i:.'~; ~,.: ! ' .' ' : '. '....:.~ .'.. .::'~: I.,>,. :,:.i?;~.%,,,.~.'.',:~ APPROVED BY DATE SlONATURE : .' ' ; ;'. : '' ';' · ;~!~',~2";'-"..~: · ' : .... .;' '.' " '" ' ' ": ' . i': .t' . .'~:'.'.;~;~;~,~.;.'..,.'.,':'?.: . ,. ;.' .... . ...; .... ,... ;: ;. i .,:;' ..~ n,. : ..... ~.) .. ~:.. ; .... ;' ., .. CITY OF BAK~SFIELD OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (661) 326-3979 INSPECTION RECORD POST CARD AT JOB SITE INSTRUCTIONS: Please call tbr an inspector only when each group of inspections with the same number a~ ~ady. They will mn in consecutive o~er beginning with number I. DO NOT cover work tbr any numbered g~up until all items in that ~up am si~ed offby the Pe~itting Authority. Following these instructions will ~duce the number of ~qui~d inspection visits and theretb~ p~vent ~sessment of additional fees. TANKS AND BACKFILL INSPE~ION I DATE I INSPECTOR Backfill of T~k(s) ' Spark Test Certification or M~ufa~tu~s Method Cathodic Protection of Tank(s) ~ a PIPING SYSTEM Co.sion Pmt~tion of Piping, Joints, Fill Pi~ ( ~l~tfical Isolation of Piping From T~k(s) Cathodic Proration System-Piping Dispenser P~ SECONDARY CO~AI~ME~, OVE~ILL PROTE~ION, LEAK DETE~IO~ Liner Installation - Tank(s) kiner Installation - Piping Vault With Product Compatible Sealer Level Gauges or Sen~o~, Flora Vent Valve, Product Compatible Fill Box(~) Product Line Leak ~tecto~s) Leak Det~to~s) for Annual Space-D.W. Tank(s) Monito6ng Well(s)/Sump(s) - H20 Test Leak ~etection Device(s) for Vadose/Groundwater Spill Prevention Boxes FINAL Monitodng Wells, Caps & Locks Fill Box Lock Monitoring Requirements Typ~ Authoffzation tbr Fuel Drop CONTACT ~. ~t ~ t.c PHONE ~ ~' ¢3 V/ ,, 2-17-2083 6: 06PM FROM CALVALLEY EOUI SECONDARY SYSTEM CEIITIFICATION FORM DATE' ~-L~:rO FACILITY ID , FACILITY ADDR~S.Ke~'~ UST Annular Space .,. .......... irallk I ~'7 L/L-... 'l'a,lk 2 .0/?_,f~- Tank 3 oi~ Tank Start 'l'ime 0¢: vs- I~i~ Il: rS- End,Time i,a,~ il:ig .... /Z: VC ,, Certlflcallou j Secondary Piping Line I g7u~. Line 2 ~/cJ'e/ Line 3 .................. O/L. Line 4 Initial pressure '~St~ 'i. ~O Page I ~ 2-17-2003 B: 06PM FR CALVALLEY EQU ! P 166132~2529 P. 3 SECONDARY SYSTEM C~RTIFICATIO~ FORM FACILITY ID FACILITY ADDRESS ~er~.N~..~ ~c~,~:l P/I~_ 3Yo/.~- ffc//~ ~e~__~ff~'~'t~ ~. Turbine Sumps t,t,,,t.Wc Sump 4 S~rt Time of Water '3.f/~'" .Y, Ttme Water lleight Time Water lleight Time ~/~ 'Water Ilcighi 3. y/2 .~ gig' Certiflcn(lon 'Overfll] Uucke~ Overfill ~ gTVo' Overfill 2 Initial/lelglit .~: 'Time, ' ;" ~!me , 3:~ 3 :~S ..~ Certification Page 2 2-17-2083 B:O6PM FROM CALVALLEY EOUIP 166132S2S29 SECONDARY SYSTEM CERTIFICATION FORM DATE FACILITY ID " FACILITY ADDRESS Kern UDC TESTING .. ~-,,/,,-L ,.# 3-'/ . $: ~ .... '~.~. DISPENSER I. DISPENSER 2 DISPENSER 3 DISPENSER 4' START TIME "'2.: INITIAL IIEIGIIT OF W, ATER ~.,~' 77" /. gz,z" 6,;.../;~;, /. 1.~ ,. TIME WATER ItEIGHT T!M~ .. ..... 2,ti z 2. z~ I: $'7 /:,ff/ WATER ii~IOUT Z~-~ 7" I, ~" q./o'--r I./~--" CERTIFICATION , DISPENSER 5 DISPENSER 6 DISPENSER 7 DISPENSER 8 : START TIME 'INITIAL ,.,. __ ATER .... TIME WATER ..... TIME, WATER HEIGiiT C~RTIn~TION (SIGNATURE) Page 3 of 3- 2-17-2003 E~: 07PM FROM CALVALLEY EOU I P 1881 ~52529 '"'"' .............. ' .......... i/'..', ~ .... .... . ' '"" '' "'"'":~,,~ TE~t ~ORT SUMP LCRK T~T ~RT '" '"'~' '" .... " ~ d:~7 ~'~ -' T~S' ". ...... e~'~ ~x'~, 82i1~ TE~T ~RRTE~ ~2/1~/2~ ' ~.',,.' B~fl L~L ' 5.872~ IH : BEGIN' ~U~ .2.2~ IH 5~ . ,~. 5.9~ ... " :,.' :':'~'.~O~ a.~2 IN L~ ~~ e.~2 KERN HIGH S~OOL DISTRIC .... :": 87 TS ..... .. .. ~7B1 E~'f ~LLE TE~CE , [.',' '., T~':,~T~ 2:Sg PN '., .~",."' V~ ST~ e~/t~ TEST SfRRTED ~:65 P~ .'..:.:..... .~L 3,~7~ ~N ?.,~ ~ ~'t~ ..~~ '...' ':' ::"." ";~':.'".:' '.'.' ..'" I ~ST R~LT .:". '::.?; ~SKD T~T STeRTED l=B2. Ph , "' T~'r 5T~T~ e2/1~ ~.,,_,".' ..,~,-~ ......... · ~ . .- ._ , . . . :' ':~ ';""~'~ ' - ' ~ ; ." ..~ .:.=~;. ~l~' C~. 9~ ~fi~R~IELO .~, 9~ [ND ~TE ~ '. ': '('~':'. ';,." L'. ' ': ,. ..... ,;.., .........:.- .. L~ T~ES~LO ~.~2 . ,;....>., . :.;:>,. .......... . '.,.', ',.,.,,.~TE~'.ST~T~ 1~:~ ~ TEST STATED, ":. .... "::: '.~.""'.:~T ~T~. ~zl~ TE~T ST~T~".:'~/'[~ TEST STATED ~2/13~BB3 · :':'. ':,~::',",.:~=~ ' S.Sl~ ZN E~ LEVEL ' ' 2;~64 IN E~ LEVEL 1.l~ .iN ~,;~."~" T~T':,~T,, ', ~ TEST RE~LT ' .P~ TE~ RE~T P~ED .~.~'~;.:'.:..:~','~" 4' .,,',. . ' ' ' '~ ., ,; ~ ' ,/~ CITY OF BAKERSFIELD ~ l ~~.,:~ OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (661) 326-3979 PERMIT APPLICATION TO CONSTRUCT/MODIFY UNDERGROUND STORAGE TANK ~_-'I~YPE OF APPLICATION (CHECK) [- ]NEW FACILITY ~IODIFICATION OF FACILITY [ ~FNEW TANK INSTALLATION AT EXISTING FACILITY FACILITYNAMI~ /~4,t #lt~/,~ ~__t~o~ ~[ ~'T' . F.3tlSTING FACILITY PERMIT NO. ~O~NO. ~ ~,,~ ?~ 7 -q ~/. s~~~us~s Li~s~o. . ~SECTIONFOI~ NON MOTOR FUrL STORACE T~KS TANK NO. VOL~ ~C~ STO~ CAS NO, ~l~ P ~O~LY STO~ ~0 B~ N~) (IF ~ ........ ~g ot~rKaM, u$~.om.¥ .......... ! ' ! APPUUA.TION DATE .... _ F~NO. ~O. ~T~ ~ ,,, ~ S .... T~ ~PU~ ~ ~D, ~~~S, ~D W~L ~MPLY W~ T~ A~AC~ ~ IONS OF THIS PE~ ~ ~ OT~R ~A~ L~ AND ~DE~ ~G~T IONS, THE ~l$ FO~ ~ BE~ ~MP L~D ~E~ r~ALTY OF PE~RY, ~ TO 8~ ~ ~ KNOWL~ IS m ~r~CA~O~ ~ECO~ A r~ ~~~o~ August 30, 2002 Kern High School District-Transportation 3701 E. Belle Terrace Bakersfield, CA 93307 REMINDER NOTICE RE: Necessary secondary containment testing requirements by December 31, 2002 of underground storage tank (s) located at the above stated address. FIRE CHIEF RON FRAZE Dear Tank Owner / Operator, ADMINISTRATIVE SERVICES 2101 "H" Street Bakersfield. CA 93301 If you are receiving this letter, you have not yet completed the necessary secondary VOICE (661) 326-3941 containment testing required for all secondary containment components for your FAX (661) 395-1349 underground storage tank (s). SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 Senate Bill 989 became effective January 1, 2002, section 25284.1 (California Health VOICE (661)326-3941 & Safety Code) of the new law mandates testing of secondary containment FAX (661) 395-1349 components upon installation and periodically thereafter, to insure that the systems are PREVENTION SERVICE~ capable of containing releases fi.om the primary containment until they are detected 1715 Chester Ave. Bakersfield, CA 93301 and removed. VOICE (661) 326-3951 FAX (661)326-0576 Of great concern is the current failure rate of these systems that have been tested to ENVIRONMENTAL SERVICES date. Currently the average failure rate is 84%. These have been due to the 1715 Chester Ave. Bakersfield, CA 93301 penetration boots leaking in the turbine sump area. VOICE (661) 326-3979 FAX (661) 326-0576 For the last four months, this office has continued to send you monthly reminders of TRAINING DIVISION this necessary testing. This is a very specialized test and very few contractors are 5642 Victor Ave, Bakersfield, CA 93308 licensed to perform this test. Contractors conducting this test are scheduling vOICE (661) 399-4697 approximately 6-7 weeks out. FAX (661) 399-5763 The purpose of this letter is to advise you that under code, failure to perform this test, by the necessary deadline, December 31, 2002, will result in the revocation of your permit to operate. This office does not want to be forced to take such action, which is why we continue to send monthly reminders. Should you have any questions, please feel free to call me at (661) 326-3190. Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services ~D July 30, 2002 Kern High School District Transport 3701 Belle Terrace Bakersfield CA 93307 REMINDER NOTICE FIRE CHIEF RE-' Necessary Secondary Containment Testing Requirements by December RON FRAZE 3 l, 2002 of Underground Storage Tank (s) Located at ADMINISTRATIVE SERVICES the Above Stated Address. 2101 "H' Street Bakersfield, CA 93301 VOICE (661) 326-3941 Deaf Tank Owner / Operator: FAX (661) 395-1349 SUPPRESSION SERVICES If yOU are receiving this letter, you have not yet completed the necessary 2101 "H' Streel secondary containment testing required for all secor~dary containment Bakersfield, CA 93301 components for your underground storage tank (s). VOICE (661) 326-3941 FAX (661) 395-1349 Senate Bill 989 became effective January I, 2002, section 25284.1 (California PREVENTION SERVICES Health & Safety Code) of the new law mandates testing of secondary FIRE SJU:ETY SERVICES * ~MENTAL SERVICES 1715 ChesterAve. containment components upon installation and periodically thereafter, to insure BakersIleld, CA 93301 that the systems are capable of containing releases from the primary VOICE (661) 326-3979 FAX (661)3260576 containment until they are detected and removed. PUBLIC EDUCATION Of great concern is the current failure rate of these systems that have been 1715 Chester Ave. Bakersfield, CA 93301 tested to date. Currently the average failure rate is 84%. These have been due vOICE (661) 326-3696 to the penetration boots leaking in the turbine sump area. FAX (661) 326-0576 FlEE INVESTIGATION For the last four months, this office has continued to send you monthly 1715 Chester Ave. reminders of this necessary testing. This is a very specialized test and very few Bakersfield, CA 93301 VOICE (661) 326-3951 contractors are licensed to perform this test. Contractors conducting this test FAX (661) 326-0570 are scheduling approximately 6-7 weeks out. TRAINING DIVISION The purpose of this letter is to advise you that under code, failure to perform 5642 Victor Ave. Bakersfield, CA 93308 this test, by the necessary deadline, December 31, 2002, will result in the VOICE (661) 399-4697 revocation of your permit to operate. FAX (661) 399-5763 This office does not want to be forced to take such action, which is why we continue to send monthly reminders. Should you have any questions, please feel free to call me at (661) 326-3190. s,¢ Steve Underwood Fire Inspector Environmental Code Enforcement Officer D June 30, 2002 Kern High School District-Transport 3701 E. Belle Terrace Bakersfield, CA 93307 REMINDER NOTICE RE: Necessary Secondary Containment Testing Requirement by December 31, 2002 of Underground Storage Tank located at 3701 E. Belle Terrace. FIRE CHIEF RON FRAZE Dear Tank Owner / Operator: ADMINISTRATIVE SERVICES 2101 'H" Street Bakersfield. CA 93301 The purpose of this letter is to inform you about the new provisions in VOICE (661) 326-3941 FAX (661) 395-1349 California Law requiring periodic testing of the secondary containment of underground storage tank systems. SUPPRESSION SERVICES 2101 'H" Street Bakersfield, CA 93301 Senate Bill 989 became effective January 1, 2002, section 25284.1 (California VOICE (661) 326-3941 FAX (661) 395-1349 Health & Safety Code) of the new law mandates testing of secondary containment components upon installation and periodically thereafter, to ensure PREVENTION SERVICES that the systems are capable of containing releases from the primary 1715 Chester Ave. Bakersfield, CA 93301 containment until they are detected and removed. VOICE (661) 326-3951 FAX (661) 326-0576 Secondary containment systems installed on or after January 1, 2001 will be tested ENVIRONMENTAL SERVICES upon installation, six months after installation, and every 36 months thereafter. 1715 Chester Ave. Bakersfield, CA 93301 Secondary containment systems installed prior to January 1, 2001 will be tested by VOICE (661) 326-3979 FAX (661) 326-0576 January 1, 2003 and every 36 months thereafter. REMEMBER! Any component that is "double-wall" in your tank system must be tested. TRAINING DIVISION 5642 Victor Ave. Bakersfield. CA 93308 Secondary containment testing shall require a permit issued thru this office and VOICE (661) 399-4697 FAX (661) 399-5763 shall be performed by either a licensed tank tester or licensed tank installer. Please be advised that there are only a few contractors who specialize and have the proper certifications to perform this necessary testing. For your convenience, I am enclosing a copy of the code for you to refer to. Once again, all testing must be done under a permit issued by this office. Should you have any questions, please feel free to contact me at (661)326-3190. Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Environmental Services SU/kr D July 1, 2002 Kern High School District 3701 E. Belle Terrace Bakersfield, CA, 93307 RE: Deadline for Dispenser Pan Requirement December 31, 2003 for Site Location at 3701 E. Belle Terrace, Bakersfield. FIRE CHIEF REMINDER NOTICE ADMINISTRATIVE SERVICES 2101 "H" Street DcaI' Underground Storage Tank Owner, Bakersfield. CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 You will be receiving updates from this office with regard to Senate Bill 989 which went into effect January 1, 2000. SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 This bill requires dispenser pans under fuel pump dispensers. On December VOICE (661) 326-3941 FAX (661)395-1349 3 l, 2003, which is the deadline for compliance, this office will be forced to revoke your Permit to Operate, for failure to comply with the regulations. PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 It is the hope of this office, that we do not have to pursue such action, which VOICE (661) 326-3951 FAX (661) 326-0576 is why this office plans to update you. I urge you to start planning to retro-fit your facilities. ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 If your facility has been upgraded already, please disregard this notice. VOICE (661)326-3979 FAX (661)326-0576 Should you have any questions, please feel free to contact me at (661)326- 3190. TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 Sin~~ VOICE (661) 399-4697 FAX (661) 399-5763 . Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services OFFICE CITY OF BAKERSFIELD , OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (661) 326-3979 APPLICATION ~TO pERFORM A TANK TIGHTNESS TEST/ SECONDARy CONTAINMENT TESTING FACILITY ~er/n ADDRESS ~7al E. iS'eib PERMIT TO OPERATE # : OPERATORS NAME OWNERS NAME /~-~ ~~ OF TANKS TO BE ~S~D ~ IS P~G GOnG TO BE ~S~ TANK ~ ~: VOL~ CO~~S ..... / ~/2~ ~7~ 2 ~12K TANK TESTING COMPANY ~'~,/- l/~lle~ ~/~me~, NAME & PHONE NUMBER OF CONTACT PERSON :~5:'/'~c~e TEST METHOD _Z',o Ca~ ~c-57-5 "' ' '~ "- NAME OF TESTER OR SPECIAl INSPECTOR-~7%4.a DATE/,&~TIME TEST IS TO BE ~ONDUCTED Y--/.,.%03 APPROVED BY DATE SIGNATURE OF APPLICAN'I D January 22, 2003 K.H.S.C. Transportation Dept FIRE CHIEF RON FRAZE 3701 East Belle Terrace Bakersfield CA 93307 ADMINISTRATIVE SERVICES 2101 "H' Street Bakersfield, CA 93301 RE: Upgrade Certificate & Fill Tags VOICE (661) 326-3941 FAX {681) 395-1349 Dear Owner/Operator: SUPPRESSION SERVICES 2101 "H' Street Bakersfield, CA 93301 Effective January 1, 2003 Assembly Bill 2481 went into effect. This VOICE (061) 326-3941 Bill deletes the requirement for an upgrade certificate of compliance FAX (681) 395-1349 (the blue sticker in your window) and the blue fill tag on your fill. PREVENTION SERVICES FIRE SAFEW SERV1CE$ * ENVIRONMENTAL 1?1set,ester^ye. YOU may, if you wish, have them posted or remove them. Fuel Bakersfield, CA 93301 vendors have been notified of this change and will not deny fuel VOICE (661) 326-3979 FAX (681) 326-0576 delivery for missing tags or certificates. PUBLIC EDUCATION 1715 ChesterAv~. i Should you have any questions, please feel free to call me at 661- Bakersfield, CA 93301 326-3190. VOICE (661) 326-3696 FAX (681)32 o676 FIRE INVESTIGATION Sincerely/~/~ 1715 Chester Ave. VOICE (661) 326-3951 / / FAX (661) 326-0576 TRAINING DIVISION St 5642 Victor Ave. Bakersfield, CA 93308 Fire Inspector/Environmental Code Enforcement Officer VOICE (061) 399-4697 FAX (661) 399-5763 Office of Environmental Services SBU/dc Dec 05 02 08:04a Kepn High School Distpiot {SG11388-7042 p.2 '? DEC 05 :~00~ 8:43 BKSFLD FIRE PREVEHTIOH (6(;1)B52-2_17;~ p.3 CITY OF BAKERSFIELD FIR]: DEPARTMENT OFFICE OF ENV', RONMENTAL SERVICES UNIFIED PROGII AM INSPECTION CHECKLIST I?IS Chester Ave., 3~ Floor, Bakerdleld, CA 93301 FACILITY NAME~,~L3 T'/'~.¢. ~'~ INSPECTION DATE [,~ -,,q-O-/' ,. ADDRESS '~'~t) I ~:~ .q,'g'L -~t/~ PHONE NO, IgC? * FACILIIY CONTACT BUSINESS ID NO. INSPECTION TIME. NUMBER OF EMPLOYEES Section !: Business Pbut mad Inventory Prog ram ~] Routine t~:~ombined {~] Joint Agency C~ Multi'Asency ~] Complaint ~ Re-inspection OPF~AIION 12 ~ COMM£NIS Appro~,,c permit ~ Im.d L /: Busine~ plan tamt~:t infonna~on ~ L Visible addre~ '~ / Con~:t occupancy Vefificaliow of iuveatmy matzri~ - Verification of quantities Vetifa:atioa of location ., "' Proper segreplion of att. tiM Vedficatioa of MSDS I,nlilabllily Verific~ion of Hnz Mai traininl .~.~' Verification of ibatemml aupplk,,,s and procedures ,,, Emergency pr°cedufu id,qualm Containcr~ p~z~cfly lab~l*d Houack¢cpifls~ Fire Pl'ole~l~on 8ire Diagram Adequate & Oa Hand_., , .,,, e' C=Compllanee Ve, Violation Any II~rdoqs wlmtl~ on lite?:.. ~ Yes [~ N a Oumiom reswdi~,_hi~_ bupesfioe? PJeme ~dl u M (6611 .J26-39~ Busiflcn Si _te/_~spofuible Party 05 02 09:04a Kern High School District (661)398-7042 p.3 DEC 05 2002 8:43 BKSFLD FIRE PREVEMTIOM 16G1)8S2-2172 p.2 CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE O1~ ENVIRONMENTAL SERVICES UNIFIED [ROGI~M INSPECTION CHECKLIST 1715 Chcst~ r Ave., 3~d Floor, Bakersfield, CA 93~01 FACILITY NAME ~5.~ ~r~. 0~ __ ~SPECTIONDArE S~lan 2: Underg~und Storage Tan~ Pro~zam ~ ~ufinc ~ombined ~ Joint ~cncy ~ Multi-Agency ~ Complaint ~ ~e-ins~ction T~ofT~k ~C$ Numb~ofTanks T~ of Monitofing ~c~ T~e or'Piping __ ~ ,, OPE~TION C V COMMENTS Proper ~nk ~ on fil~ ~ / ~pcr own~op~ntor dn~ on lile Pc~it t~s cu~t ~ ~ C~ificafion 0fFinancial ~po~ibility ~ ' Monito~ng ~ord ~m ~d cu~t M~nt~oe r~or~ ~te a~ cu~m Failure ~ ~ ~r UST ~olations H~ th~ ~ ~ unadorned ~l~se? Yes No ( ~ ~cflon 3: Abo~gro=nd Storage Ta~ ~og~ am TA~K SIZE(S}. AGG~GATE CAPA~. T~e of Tank Num~ of Tan~ sPCC available $PCC on file with OES [ I Pr~ ~nk pla~din~la~lln8 C=C~pli~ce V=V~lati~ Y-Y~ N=NO I~p~t~~ O~ of~nvi~nmeot~l ~rvic~ (805) 3~6-307~ ~USi~5 Site R~pousible Pa~ · Whi~ - ~av. Sves. Pink - 9,~i~ · Complete items 1, 2, and 3. Also complete item 4 if Restricted Delivery is desired. [] Agent · Print your name and address on the reverse [] Addressee SO that we can return the card to you. '~ · Attach this card to the back of the mailpiece, Dat~of ~-/~i¥ ._, D~,v,rv_ or on the front if space permits. D. Is delivery from item 17 [] Yes 1. Article Addressed to: If YES, enter delivery address below: [] No KERN HIGH SCHOOL DISTRICT 3701 EAST BELLE TERRACE BAKERSFIELD CA 93307 3. Service Type ~3 Certified Mail [] Express Mail [] Registered [] Return Receipt for Merchandise [] Insured Mail [] C.O.D. 4. Restricted Delivery? (Extra Fee) [] Yes tI= ............. ~-00,2 0660 oono 1641 6698 ,1 PS Form 3811, August 2001 Domestic Return Receipt 102595-02-M-0835] Postage & Fees Paid USPS Permit No. G-lO Sender: Please print your name, address, and ZIP+4 in this box ° Postage $ Ce~ified Fee Po~ Return R~eipt Fee (Endowment R~ul~ Hem R~ Delivew F~ (En~t R~ui~ To~l P~ge & Fees Sent To ~;~;C~:'~:; .............................................................................. [~:r~.~:..E~.~J...~.~.SE..~[.~.~ ................................. October 31, 2002 Kern High School District 3701 East Belle Terrace Bakersfield CA 93307 CERTIFIED MAlL REMINDER NOTICE FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES RE: Necessary secondary containment testing requirements by December 31, 2002 of 2101 "H" Street underground storage tank (s) located at the above stated address. Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 Dear Tank Owner/Operator, SUPPRESSION SERVICES 2101 'H' Street If yOU are receiving this letter, you have no_.3t yet completed the necessary secondary Bakersfield, CA 93301 containment testing required for all secondary containment components for your underground VOICE (661) 326-3941 FAX (661) 395-1349 storage tank (s). PREVENTION SERVICES Senate Bill 989 became effective January 1, 2002, section 25284.1 (California Health & Safety FIRE SAFETY SEIWlCES , EN~IRONI~.~TAL SERVICES 1715 ChesterAve. Code) of the new law mandates testing of secondary containment components upon installation Bakersfield, CA 93301 VOICE (661)326-3979 and periodically thereafter, to insure that the systems am capable of containing releases from FAX (661) 326-0576 the primary containment until they are detected and removed. PUBLIC EDUCATION Of great concern is the current failure rate of these systems that have been tested to date. 1715 Chester Avi~. Bakersfield, CA 93301 Currently the average failure rate is 84%. These have been due to the penetration boots leaking VOICE (661) 326-3696 FAX (661) 326-0576 in the turbine sump ama. FIRE INVESTIGATION For the last six months, this office has continued to send you monthly reminders of this 1715 ChesterAvo. necessary testing. This is a very specialized test and very few contractors am licensed to Bakersfield, CA 93301 VOICE (661) 326-3951 perform this test. Contractors conducting this test are scheduling approximately 6-7 weeks out. FAX (661) 326-O576 The purpose of this letter is to advise you that under code, failure to perform this test, by the TRAINING DIVISION 5642 V~tor^ve. necessary deadline, February 16, 2003, wffi result in the revocation of your permit to Bakersfield, CA 93308 operate. VOICE (661) 399-4697 FAX (661) 399-5763 This office does not want to be forced to take such action, which is why we continue to send monthly reminders. Should you have any questions, please feel free to call me at (661) 326-3190. Ss i~~erwo~~~ Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services L D September 30, 2002 Kern High School District 3701 East Belle Terrace Bakersfield CA 93307 REMINDER NOTICE FIRE CHIEF RON FRAZE RE: Necessary secondary containment testing requirements by December 31, 2002 of ADMINISTRATIVE SERVICES underground storage tank (s) located at thc above stated address. 2101 "H' Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 Dear Tank Owner [ Operator. SUPPRESSION SERVICES If you are receiving this letter, you have not yet completed the necessary secondary 21Ol "H' Street containment testing required for all secondary containment components for your underground Bakersfield, CA 93301 VOICE (661)326-3941 storage tank (s). FAX (661) 395-1349 Senate Bill 989 became effective January 1, 2002, section 25284.1 (California Health & Safety PREVENTION SERVICES ,=£ s,~ms~,~cES.~,~SE,,CES Code) of the new law mandates testing of secondary containment components upon installation 1715 ChostorAve. and periodically thereafter, to insure that the systems are capable of containing releases from Bakorsfleld, CA 93301 VOICE (661) 326-3979 the primary containment until they are detected and removed. FAX (661) 326-0576 PUBMC EDUCATION Of great concern is the current failure rate of these systems that have been tested to date. 1715 ChestorAV~. Currently the average failure rate is 84%. These have been due to the penetration boots leaking Bakersfield, CA 93301 in the turbine sump area. VOICE (661) 326-3696 FAX (661) 326-0576 For the last five months, this office has continued to send you monthly reminders of this FIRE INVESTIGATION necessary testing. This is a very specialized test and very few contractors are licensed to 1715 Chester Ave. Bakersfield, ca 93301 perform this test. Contractors conducting this test are scheduling approximately 6-7 weeks out. VOICE (661) 326-3951 FAX (661) 326-0576 The purpose of this letter is to advise you that under code, failure to perform this test, by the TRAINING DIVISION necessary deadline, December 31, 2002, will result in the revocation of your permit to operate. 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661)399-4697 This office does not want to be forced to take such action, which is why we continue to send FAX (661) 399-5763 monthly reminders. Should you have any questions, please feel free to call me at (661) 326-3190. Sincere/. Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services 10/04/2002 FR[ 08:29 FAX ~001/002 / .e~o~ ' KERN HIGH SCHOOL DISTRICT BOARD OF TRU~TEE~ ~b J. H~p~ Pr~i~t J. B~ Ba~, VI~ ~ent ~ D, ~~ S~ERI~E~E~ ~te: . _.. _ Message: Number of pages sent (includes cover sheet):~ Sent by: ~r~)'~ - ' f_j~' '(Nama?'0epartaent/Ext. ) IF YOU DO NOT RECEIVE ALL PAGES, PLEASE CALL (661) 827-3181 KERN HIGI~ S~-IOOL D~STRIG~ Malme~anoe & Oaeeattm~ :~701 E. Belle Terrace. Suite Ne. A-. ·., Buka~ield, ~ ~3C)7 fax # (661) 833-0870 AN ~ OPPOR'IA~II'Y EMPLOYER 10/04/2002 FR! 08:29 F~ ~1002/002 / K.g HIGH SCHOOL DIS CT ~ ~h ~ Wa~~r O~ob~ ~, 2002 TO: Bud Benkstor~ Director Transportation FROM: lohn Fox, Assistant Director ~ E~t~ and ~ons~ - P~: Necessary Secondary Containm~ T~-~ Requir~ Bud, I received & letter from the Bakersf:~d Fire Department. Please read throush thc letter and I have some h~mu~on that I gathered from Steve U~lerwood. First of all, Senate Bill 989 is a ~st of the secor~lar~ containm~t compon~s that w~just recently installed on the fuel islands. Steve said althou~ the deadlh~ for this test is ~ 31, 2002, this is actually not d~e unlit Febmar~ of 2003. Steve should be se.~di~ a r~Msed l~er to slate this, bm if you warn to contact Cai Vall~ ~, th~ could p~'om~ thist~st, I am ~ Steve said that there is a $64 fee to p~ll a pemut for tho Senate Bill 989 tes*~ but tho good news is that you would not have to retest tho soco~clary containment componeaIs ,,mil Februaly 2006. Anoth~- item th~ Steve had mentioned to me is that you must have your monitorln$ ~ ~ te, s~l on a yearly basis, and the due date on this for your facility would be Au~m~st 16, 2003. Thea it would have to bc tested on a yearly basis aiter that. He~al~ stated that Cai Valley could perform this test also. Chuck M~dors L 4:~UL 8-4 }(ER[',~ HIr]H ~,:::.HOOL DST [)i© :, ~.,, 3701 E.BELLE TERR~(;E FUEL ~L~RII B~kER~,F I ELD '~ ¢' t_.~. ~U(~ 16 2002 5:06 PI~I 66t-827-3199 ¢ ' " RUG 16., 2002 5:05 ~ SYSTEId STATUS REPORT T 3:PROBE OIJT ..... SEf~SO~ ~LRRt'.I .... L U.,~E,i.~.R OUT ~LARI"I L 3:RUL 1-2 LIO:SEIqSOR OLiT ~L~R["I FUEL ~L~RPI ~U,'? 1 1 NVENT(:'RY REPORT T i :I_II~LE~DED VOLUME = '76:39 ,:::ALS iJLLR(;E = 4:384 98:~: LILLRGE= 318t GaLS TC; '¥'OLUME = 7510 OR'~ t4RTER VOL = 0 GaLS L 2:RUL I.,&TE~ = O. 00 1N(:HES STP TEPlP = 84.1 BEO F FIJEL T 2: D I ESEL VOLUP1E = 686:3 GaLS ULLaCE 5160 [~ALS 90~[ ULLAGE= 3957 (;aLS T(: VOLUME = 6784 GALS HEIGHT = 61.57 INCHES t,&TER VOL = 21 t4RTER = i. 18 I f'qCHES TEPIP = 85.6 DEG F ,:__y[ p - .... L 6:D1E~EI. STP STP ~JNP FUEL ~LARM ~UG 16, 2002 h 8:D~L 6 [',~ BPENff]ER PAN FUEL ~LARM Ali,] 1~,, 2002 5:09 Plq RELAY OUTPUT TE~'I' AIJ~] ~ 6, 21-JI]2 5:1 5 Pl'i R 2:OVER-FILL ALARM TYPE: ~TA NDARD NORNALLY OU:],SED L '7 :DSL 5 I N.-T~NK ALARMS D [ SPEN;5;ER P~N ALL: OVERF l LL FUEL AL~RN ~UG 1~. 2002 5:10 PN SENSOR ALAD.'I ...... ESEL A I',II',iUL~R 6. 201-12 5:1~ PP1~ SYSTEM SETUP SYSTEM SECURITY ............ .- CODE : 000000 aUG Ia. 2002 5:19 Pi SVSTEI"I uN ITS I_J. S. , ~--., SYSTEM LANGUAGE ENGL 1SH SYSTEM DaTE.,.'TIME FORMAT MON DD YYYY aH.Illl ..... xM KERN H ICH S{-]HCIOL DST C~OMHUN I c-;aT I {."NS SETUP 3,?01 E.BELLE TERRaOE ......... B~}::'.ER,SF I ELD c'~.a.'. ~,G, 1-8'27-3199 PORT SETTI NOS '3HIFT TIME 1 : 6:00 AM SHIFT TIME 2 : I]ISABLED NONE FOUND .S;HIFT TIME -4 : DISABLEr) SHIFT TIME 4 : DISABLED TaNK PER TST NEEDED WF:N D I SABLE£', '-' '-'""-' R,~-~o~ END GF T~I'.I}:.' ANN TST NEE[',ED I DISABLED 1-) I SaBLED LINE RE-ENaBLE METHOB PASS L I NE TEST LINE PER TST NEEDED WP, N [) I SABLED LINE ANN TF_:T NEEDED WRN D 1SABLED PRINT TI]; VOLUMES ENABLED I N-TANK SETUP TEPID' COMPEI',ISAT 1 ON VALUE (DEG F ): 60.0 T I:UNLEAI}ED STICK HEIGHT OFFSET PRODUCT (.,'.ODE : I}I SABLE[) THERMAL r:OEFF :. 000700 DA'¥'I.. I GHT sa',,,' I I',IC; T I ME TAN}:.', D I AMETER : 111 . O0 ENABLED TaNK PROFILE : 4 START D~TE FULL VOL : 12022 q'~'-' 1 APR WEEK 1 SUN 1:313.3 INCH VOL : - 55.5 INCH VOL : 601l START TIME ~ 27.8 INCH WOL : 9;341-1 2: 00 aP1 . - - END [)ATE c, , t~/-~-,' .....--~--- OCT WEEK ~:.~ ,_, I[,l END TIME '2: O 0 AP1 T 2 :DIESEL PRODUCT F:ODE : 2 ,-~ ..... THERMAL COEFF :. 000450 FLOAT BIZE: 4.0 IN. 3~I,IK BI~I"IETER : lll.O0 T~I'IK F'ROFILE : 4 PTS bJ~TER ~,,.t~l,l I NO : 0 FUL. L VC.L : 1202:3 HIGH baRTER LIMIT: ~. O 83 3 INCH ',/OL : . 55.5 INCH VOL : 6011 MaX OR L~BEL VOL: 12023 27.8 IIqCH VOl. : 2:340 OVE~FI LL LIMIT : : 11421 H I GH PRODUGT : 90~: FLOAT S l ZE: 4. : 10820 DELIVERY LIMIT ; 10% 14ATER bJARNING : : 1202 HIGH bJATER LIMIT: I.Ob,I PRODUCT : 600 MAX GR LABEL V:]L: 1202:3 I.E~),~ ~L~R~"I LIMIT: 99 OVERFILL LIHIT : 95% ~UD[,tEN LO~ LIPIIT: 99 : 11421 T~N},:: TILT : ,1.00 HIGH PRODUCT : 90Z PROBE OFFSET : O. O0 : 10820 DELIVERY LIMIT : : 2404 P1ANIFOLDED TANK~ T~: NONE LOCI PRODLICT : ~,00 LE~:~K aLaRM L I M I T: 99 SUDDEN LOSS LIMIT: 99 LEAK MIN PERIODIC: ~ TaNK TILT : 0.0~ : 2404 PROBE OFFSET : O. O0 LEAK MIN ANNUAL : : 4809 MANIFOLDED TANKS T~: NONE PERIODIC TEST TYPE STaNDaRD LEaK M I N PER I OD lC: : ANNUAL TEST FaIL gLg~PI DISABLED LEaK l'-ql N aI'4NLIgL : 40% : 4809 PERIODIC TEST FaIL aLaRM DISaBLED PERIOD1C TEST TYPE F3ROSS TEST FAIL ~3UIC;K ALARP1 b ISABLED A[',INU~iL TEST FA I L ANN 'rEST AVERAGING: OFF ALARM DISABLES PER TEST g'dERaGI N¢: OFF PER l OD I C 'rEST Fg [ L TaNK 'rEST NOT I FY: . OFF ~LaRP1 DISaBLED TNK TBT SIPHON B~E~K:OFF GROSS TE~T F~IL ALARM DISABLED DEL 1VERV BELAY ; '3 PII N PUMP THRESaOLD : 10. 00~.; aNN TEST AVERAGING: OFF PER TEST AVERAOI NC:: OFF TANK TEST NOTIFY: TNK TST SIPHON "'~ .... DELIVERY DELAY : 3 MIN " PUI"lP THRESHOLD : 1U.00% T B:¢JASTE OIL F'R,i~DUC;T b~ I E '~'HER['.'I~L C,DEFF :. TANK D I ~'IETER T~NK PROFILE : 4 PTS FULL VOL : 201~ 46.0 INCH VOL 2~.l-J ]NCH ',JOL : 394 TEST ON D~TE : ALL T~ J~N 1 .. 1998 START TIP1E : BIS~BLED lq~'?: OR LABEL VOL: 20~4 TEST RATE :0.20 GAL/HR OVERFILL LII'ilT : 95% DURaTiON : o HOURS : 19~:3 HIGH PRODWCT : 90% TST E~RLY STOP:DISaBLED : 18t2 DEL I~ER"¢ L 1~'"lI% : 0% LEAK TEBT REPORT FORN~T : 0 E N H~ NCED LOO~ pRODUCT : 0 LEAl( &L~RIq L1H1T: 99 Lt:,- LIPllT: 99 T~NK TILT : 0,00 PROBE OFFSE'T : O- O0 NAN I FOLDED T¢: NONE LIOJID SENSOR SETIJP LEAK PIIN PERIODIC: 10% .............. : 201 L 1 :RUL ANNULAR LEAK NIN gI'.INU~L : [0% TRI-.BT~TE 'SINGLE FLO~T) : 201 C~TEGORY : RNNULRR SPACE ANNUAL TEST FAIL RLARPI B [ SgBLED L '~: RUL STP PERtODIC TEST FAIL C~TEGORY : STP ~UP1P ALARIq D I SRBLED GROSS TEST FAIL L 3:RUL 1-2 L.,~TEt,(¢~Y : I)I,_FEIL, ER PAN al,IN TE'ST AVERAGING: OFF PER TEST A'v'ERAG I NG: 'F TANK TE~T NOT I F'/: OFF TNK '[ST SIPtdON BREAK :OFF DEL I VERY DELAY : 3 ~'.'11 N PUPIP THRESHOLD. : 10.00% L 4:RUL 3-4 TR I -STATE (S INGLE FLOAT) CATEGORY : DISPENSER PaN L ~: I31 ESEL AI',INULaR TR I -STATE (S I IqE;LE FLOAT CATEGORY : ANNULAR S~ % L.6:DIESEL STP TRI -STATE < SI NGLE FLOAT ) CATEGORY : STP SUMP OUTiZ~UT RELAY SETUP L 7:DSL B - - - 'FA I -STATE ( S INGLE FLOAT ) CATEGORY : DISPENSER PaN R i:RUL--STP TVPE: STaNBR~9 I,,IORPlaLLV CLO~ED L 8:DSL 6 'FA I -~]'A]"E < ,_, I N _,LE FLOAT ) C~TEGORY : D 1 SPENSER PaN LIi3U 1D SENSOR ALl-iS L 1 :~UEL L 2 :FUEL L S :FUEL L 9: WASTE O I L AN[',IUL~-~R L 4: FUEL. ALARI'"t TRI-STATE (SI NGLE FLOAT.> L 1 :SENSOR OUT aLaRM ..rq]E~.R~ : A[',INUL~R ~P'"'E L 3:SENSOR OUT ALARM ~ L. 4;SENSOR OUT ALARI't L 1 :SHORT aLhRI'"I L 2:~HORT aLaRM LIO:WaSTE aLL STP L ~:SHORT ALAR¢I TR 1 -STATE ,'. SI NGLE FLOAT) L 4 :SHORT ALARI't CATEGORV : PIPING SLIPIP R 2: D 1ESEL-STP T",'PE: L1 1 :LUB-O1L SUMP I STANDARD TRI -STATE (SI NGLE FLOAT) : NORMALLY CLOSED CATEGORY : PI[:'ING SUMP ' L12:LUB-OIL 2 E.ISLaNr., TRI-STATE (SINGLE FLOAT) CATEGORY : PlPIN(; SUMP L. 1S:LUS-OIL :.3 W.1SLaND TR I -STATE (SI NGLE FLOAT CATEGORY : PIPING SUHP F,'ECOf:IO I L I ~ T I ON ~ LITOpi~ T ' '- TIPI~. ,~L.: D~qlLV ~'?LOSI ~ ' c: O0 &I"l NC; PDDE': ' ~EOONOILIATI,L3N TEPId:, OOh'lPEN,~ T I Or, P10 NTNL y ST~t'qEI~D '- , 1 BaS SLOT FUEL HETE~ ~ Date: I authorize my company to pay $30.00 per hour for the off-hours worked by a City of Bakersfield Environmental Services Division employee for removing, installing, or upgrading an UST. Total amount: ,,., Company employee and title: Employee signature: Company name: Environmental Services Division ~ ~O0 · Address: City, State, Zip Code: :- Phone: :- a:\form\UGST 12-22-98 CITY OF BA~SFIELD OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (661) 326-3979 INSPEC~TrlON RECORD POST CARl AT JOB SITE INSTRU~IONS: Ple~e call ~or ~ ins~tor only wh~ :ch ~up o~i~tions ~th the ~ mutant ~ ~dy, They will mn in co~ufive o~et be~nning with numar I. ~ NOT cover wo~ for ~y num~ ~up ~til all it~ in ~ ~up ~ si~ offby t~ Pe~itfing Autho~, Follo~ng t~ instmctio~ will reduce the numar of ~ui~ i~tion visim T~ ~ ~C~IL~ ~SPE~ON DATE ~ ~SPE~OR B~kfill Sp~ T:t Certification ut M~uf~tu~ M~ Cath~ic Proration of T~k(s) PIPING SY~M Piping & ~c~y w/~p I ' El~cal l~on of Pip~8 From T~(s) Cath~ic P~lion S~em-Piping SECONDARY' CO~AIN~, O~ILL PR~E~iON, LEAK DETE~ION Liner l~allaion Liner lnsallation - Piping Vault With P~uct ComNible ~1~ ~el Oaug~ or ~a, Rat Vmt Vg~ P~uct ComNible Fill Box(o) P~uct Line L~k ~t~toKs) Le~ ~tect0Ks) for Annual Sp~e-D,W, T~k(s) L:k ~tion ~vic~s) For V~o~Omund~lcr FINAL Monitoring W~ll~. Fill Don L~k Autho~tion ~or Fuel ~p ~ _, '~'uoi ,)?6 0576 BFD itAZ MAT D[¥ ~002 OFFICE OF ENVIRONMENTAl, SERVICES - ~, ~ _ 1715 Chester Ave., Bakersfield, CA (661) 326-3979 tO '90 t ~ PERMIT APPL/CATION TO CONSTRUCT/MODIFY UNDERGROUND STORAGE TANK ~_TY~V_ Ot' A~InJCAT'tON { ]NEW FACIL/TY ~ODII:ICATION OF FACILITY [ ]NEW TANK INSTALl. AT[ON AT EX/STING FACTt tTY FACILITYNAME [t~'~.g~, #lt,~ ,~c_[,~a, O / ~7" . F, XlSTING FACILITY PERMIT NO. _ TANK OWN-aR ~/~~~~ ~ PtlONE NO. PHONE NO. ~ CfTY B~ LICI~',,'$.E NO. DEl'TH TO GROUND WATER ~OIL 'TYPE liXP~ AT SlTE 5PI1.L P~ON CONTROL AND COUNTER MEASURES P LAN ON FILE __. ' ~.--""7'~%[~ , NO SEC'ElaN FOR MOTOR FUEL TANK NO. VOLUME UNLEADED REGULAR PREMIUM D/ESEL AVIATION _sz~'r~o~ lroM wo~ MOTOR FtW. L STORA~y. TANI~ TArOt ~O. VOLUME cm~mcAL STORED CAS NO. ctn~ p m~VtO~LY STOR~ l:~)K OFF.AL USE ONLY THE. APPU~ HA~ RECEIVED, UN~ANDS, AND W~L ~MPLY W~ T~ A~AC~ ~ tONS OF THIS P~ ~ ~ ~ ~A~ L~ AND ~D~ ~O~T I~ ~lS FO~ ~ B~ ~P L~D ~ER P~ALTY OF P~KY, ~ TO THE g~ ~ ~ ~OW~ ~ / ChemiCal R istance.For All to 2" Pipe Using Nylon 12 Pipe Liner Poly-Tech Nylon 12 is resistant to the following chemicals (testing done at 20°C): (If the chemical that you are looking for is not on this list, contact APT) Acetaldehyde Fatty Acid Esters Oils Refined Acetic Acid (10%) Formaldehyde Oleic Acid Acetic Acid Butyl Ester Freon 12 Olive Oil Acetic Acid Ethyl Este¥ Freon 22 Pahn Nut Oil Acetone Freon 502 Paraffin Oil Acetylene Furfuryl Alcohol Peanut Oil Aliphatic Petroleum Distillate Gas (Coal) Peppermint Oil Aluminum Sulfate Gasoline (Alcohol Blends) Perchloroethylene Ammonia Gasoline (High Octane) Petroleum Ether Ammonium Hydroxide Glucose Phosphoric Acid , Ammonium Nitrate Glycerine Potassium Carbonate Ammonium Sulfate Glycol Potassium Chloride (I 0%) Amyl Acetate Greases Potassium Hydroxide (1%) Aniline Heptane Potassium Nitrate 'Aviation Fuels Hydraulic Fluid Propane Barium Chloride Hydrogen Propyl Acetate Beer Hydrogen Peroxide (3%) Pydraul F9 t Benzaldehyde Hydrochloric Acid (10%) Silicone Oils Benzene Hydroxy Quinoline Soap Solution Brake Fluid Isopropyl Alcohol Sodium Chloride (10%) Butane Kerosene Soduim tlydroxide (1%) Butyl Alcohol Lacolene Sodium Hypochlorite (10%) Calcium Arsenate Lactic Acid Sodium Sulfide Calcium Chloride (10%) Linseed Cake Stearin Calcium Hypochlorite Linseed Oil Stearic Acid Calcium Nitrate Lubricating Oils Styrene Monomer Camphor Magnesium Chloride Sulfuric Acid (10%) Carbon Disulfide Mercury Tartaric Acid Chloroform Methane Tetraethyl Lead Cider Methanol Tetrahydrofurane Citric Acid (10%) Methyl-Alcohol, Aq. Toluene Copper Sulfate Methyl-Cellosolve Transformer Oil Cyclohexane Methyl Acetate Tricresyl Phosphate Cyclohexanone Methyl Bromide Tributyl Phosphate D.D.T. Preparations Methyl Chloride Trisodium Phosphate Diammonium, Phosphate Methyl Sulfate Triphenyl Phosphate Diesel Fuels Methylethyl Ketone Turpentine Diesel Oil Methyltertbutyl Ether Urea Diethanolamine Milk Uric Acid Diethyl Ether Mineral Oils Vinegar Dioctylphosphate Motor Fuels Water Dioctyl Phthalate Motor Oils Water (Salt) ETBE(Ethyl T-Butyl Ether) Mustard Water (Soda) Ethyl Acetate Naptha Wine Ethyl Alcohol (Ethanol) Naphalene Xylene Ethyl Alcohol Octane Zinc Chloride Ethylene Glycol Oil (ASTM No. 3) Ethylene Oxide Oils Crude Rev. 9/97 Chemical l~sistance For All 3~to 4" Pipe Using Nitrile Pipe Liner Poly-Tech Nitrile is resistant to the following chemicals: (If the chemical that you are looking for is not on this list, contact APT) Acetylene Hydrogen Water (Salt) Aliphatic Petroleum Hydrochloric Acid Water (Soda) I)istill ate I l yd i'{>xy Qu inoli nc Wi nc Aluminum Sulfate Isopropyl Alcohol Zinc Chloride Ammonia Kerosene Ammonium Nitrate Lacolene Ammonium Sulfate Linseed Cake Aviation Fuels Magnesium Chloride Barium Chloride Mercury Beer ~ Methane Butane Methanol Butyl Alcohol Methyl Sulfate Calcium Chloride Methyltert~utyl Ether Calcium Nitrate Mustard Camphor Naptha · Cider Oils Crude Citric Acid 0ils Refined Copper Sulfate 01eic Acid Cyclohexane Potassium Carbonate D.D.T. Preparations Potassium Hydroxide Diammonium Phosphate' Potassium Nitrate Diesel Fuels Propane ETBE(Ethyl T-Butyl Ether) Propyl Acetate Ethanol ,, Soap Solution Ethylene Glycol Sodimn Chloride Fatty Acid Esters Soduim Hydroxide Formaldehyde Sodium Sulfide Freon 12 Stearin Gas (Coal) Sulfuric Acid (10%) Gasoline (Alcohol Blends) Tartaric Acid Gasoline (High Octane) Tetraethyl Lead Glucose Trisodium Phosphate Glycerine Urea Glycol Uric Acid Greases. Water Heptane Rev. 9/97 B D May 30, 2002 Kern High School District Transportation 3701 E. Belle Terrace Bakersfield, CA 93309 RE: Deadline for Dispenser Pan Requirement December 31, 2003 on Underground Storage Tank(s) located at 3701 E. Belle Terrace, Bakersfield'. FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES Dear Underground Storage Tank Owner: 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 YOU will be receiving updates from this office with regard to Senate Bill 989 which went into effect January 1, 2000. SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 This bill requires dispenser pans under fuel pump dispensers. On December VOICE (661) 326-3941 FAX (661) 395-1349 31, 2003, which is the deadline for compliance, this office will be forced to revoke your Permit to Operate, for failure to comply with the regulations. PREVENTION SERVICES 1715 Chester Ave. Ba~e,~t~e~d, c^933o~ It is the hope of this office, that we do not have to pursue such action, which VOICE (661) 326-3951 FAX (661) 326-0576 is why this office plans to update you. I urge you to start planning to retro-fit your facilities. ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 If your facility has been upgraded already, please disregard this notice. VOICE (661) 326-3979 FAX (661)326-0576 Should you have any questions, please feel free to contact me at (661)326- 3190. TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 Sincer~_ VOICE (661) 399-4697 FAX (661) 399-5763 Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/kr MONIT( I, NG SYST M CERTIFIC i ~/// .4 * F. or U~733 All.]u,'isdicfio,,s Withi,, the State of Cal(ro,.~ l~lhority Cited: Chapter 6. Z l~ea#h and SafeO, Code; Chapter l ~, Division 3, Title 23, Cal~ornia Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or repoR mu~t prepared for each monitoring system control panel by the technician who performs the work. A copy of this fo~ must be provided the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating usT systems withi, 30 days of test date. A. General Information Facility Nan, e: ~C ~fll )/] Sc] et, / Bldg. No.: Site Ad&ess:, ~/~ ~e//t ~l'~,t' City: ff~?Yd~?/~ Zip: Facility Contact Person: ~// ~/d~r__ Contact Phone No.: (gb/) ~2~- Make/Model of Monitoring System: Ge'/&¥ro [bna' Dl~ts/p~r ~ Date ofTestin~Servicing: ~-/~ /~ B. InventotT of Equipment Tested/Certified X&'~'3/~ ,~. Check the appropriate boxes to indicate specific equipment inspected/serviced: · ' [ ...... ~ In-T~k Gauging Probe. Model: ~ ~n-Tank Oaugin~ ~robe. - Model: ~,; ~ Annular Space or Vault Sensor. Model: g~q ~,a~ ~dOV ffi Annular Space or Vault Sensor. Model: ~' ~ Piping Sump /Trench Sensor(s). Model: X~i~ 5~0('0~ ~ Piping Sump / Trench Sensor(s). Model: ~.t[ ~'~' Yt~Ft~. D Fill Sump Sensor(s). Model: D Fill Sump Sensor(s). · Model: ~ ' ~ Mechanical Line Leak Detector. Model: ~[7 D Mechauical Line Leak Detector. Model: ~ .... ~ Electronic Line Leak Detector. Model: ~ Electronic Line Leak Detector. Model: , ~ 'rank Overfill / High-Level Sensor, Model: D Tank Overfill / lligh-Level Sensor. Model: ~, ~, ~ Other (specify equipment type and model in Section E on Page 2). ~ Other (specify, equipment type ~d model i~ Section E 0d Pflg~ 2}i -- ,,. ln-T~k Gauging Probe. Model: ~ In-Tank Gauging Probe. MOdel: ~ l, · ~ Piping Sump / Trench Sensor(s). Model: ~ Piping Sump / Trench Sensor(s}. Modek ~ ~;; D Fill Sump Seusor(s). Model: ~ Fill Sump Sensor(s). Model: ~ ~ ~ Mechanical Line Leak Detector. Model: ~ Mechanical Line Leak Detector. Model: i ~ Electronic Liue Leak Detector. Model: D Electronic Line Leak Detector. MOdel: ~ . "" ~ Tank Overfill / Iligh-Level Sensor. Model: D Tank Overfill / lligh-Level Sensor. Model: ~ Other (specify equipment type and model in Section E on Page 2). ~ Other (specify equipment type and model in Section E on Page2); Dispenser ID: [ Dispenser ID: ~ D Dispenser Containment Sensor(s). Model: D Dispenser Containment Sensor(s). Model:. ~ Shear Valve(s). ~ Shear Valve(s). ~ Dispenser Containment Float(s) and Chain(s). ~ Dispenser Coutainment Float(s) and Chain(s). Dispenser ID: .~ Dispenser ID: D Dispenser Containment Sensor(s). Model: D Dispenser Containmeut Sensor(s). Model: ffi Shear Valve(s). D Shear Valve(s). Q Dispenser Containment Float(s) and Chain(s). ~ Dispenser Containment Float(s) and Chain(s). Dispenser ID: ~ Dispenser ID: ~ Dispenser Containment Sensor(s). Model: D Dispenser Contalnment Sensor(s). Model: ~ She~ Valve(s). D Shear Valve(s). QDispenser Contaiament Float(s) ~d Chain(s). Q Dispenser Containment Float(s) ~d Chain(s). · If)he facility contaius more tanks or dispensers, copy this form. Include information for eve~ tank and dispenser at the facility. C.' Certification - I certify that ~the equipment identified in this document was inspected/serviced in accordance wilh manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to Verify thai thl~ information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating s~ch reports, 1 have also atlached a copy of the report; (check all that apply): ~ System set-up ~ Alarm history repor~ Techniciau Name (print): ~]r~ ~>tJ/~r .... Signature: '~.~ ~ Certification No.: ~'~¢¢'7~ License. No.: '~W~O ~ Testing Company Name: E~/'~.~/E~f ~.~//~lt~t~ Phone No.:( ~/ ) 3 2 Site Address: ~7~/ ~, ff~ff~ '~I/l~cCC ~&~t~:~'~A~ ~.0, ~90~ Date of Testing/Servicing: ~ / Z Page I of 3 03/01 Monitoring System Certification ' /, Results of Testing/Servicing Software Version Installed: Complete the following checklist: ... ~ Yes [] No* Is the audible alarm operational? Yes 121 No* Is the visual alarm operational? i~ ,: ..... Yes [] No* Were ail sensors visually inspected, functionally tested, and confirmed operational? Yes FI No* Were ail sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation7 F! Yes ~ No* if alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) N/A operatipnal? ~ Yes No* For.pressurized piping systems, does the turbine automatically shut down if the piping seconda~ containment ~ N/A monitoring syste~n detects a leak, Jails to operate, or is electrically disconnected7 l[yes: which sensor~ inmate positive shut-down? (Check all that apply) ~ Sump/Trench Sensors; ~ Dispenser Containment Sensor~ Did you confirm positive shut-down due to leaks and sensor hilure/disconnection? ~ Yes; ~ No. '~. ~ Yes ~ No* For tank systems that utilize the monitoring system as the prima~ tank overfill warning device ffi N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible a[ the tank fill point(s) and operating properly? If so, at what percent of tank capacity does the ala~ trigger7 · ~ Yes* ~ No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced aud list the manuhcturer nmne and model for all replacement parts in SectiOn E, ~elow. ~ Yes* ~ No Was liquid found inside any secondary containment systems designed as d~ systems7 (Ch,ck all that apply~ ~ Product; ~ Water. If yes, describe causes in Section E, below. ~ Yes ~ No* Was monitoring system set-up revieWed to ensure proper settings? Attach set up repo~s, if applicable ~ Yes ~ No* Is all monitoring equipment operational per manufacturer's specifications7 ~ In Section E below, describe how and wheu these deficiencies were or will be corrected. E. Comments:' :. In-Tank Gauging / SIR EquiI ~I Check this box iftank gaul is used only for inventory control. [] Check this box if no tank gauging or SIR equipment is Installed. This section must be completed if in-tank gauging equiptnent is used to perfo.n leak detection monitoring. Complete lhe following checklist: [] Yes I-I No* l-las all input wiring been inspected tbr proper e.try and termination, including testing for ground faults? [] Yes [] No* Were all tank gauging probes visually inspected for damage and residue buildup? Fl Yes ~ No* Was accuracy of system product level readings tested? [] Yes [21 No* Was accuracy o£system water level readings tested? [] Yes [] No* Were ail probes reinstalled properly? [] Yes [] No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section 1t, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): [] Check this box ifLLDs are not installed. Complete the following checklist: ~ Yes [] .No* For equipme,t start-up or a.nual equipment certification, was a leak simulated to verifY LLD performance? [] N/A (Check all that apply) Simulated leak rate: ~'3 g.p.h.; [] 0.1 g.p.h; U! 0.2 g.p.h. ~} Yes [] No* Were all LLDs confirmed operational and accurate within regulatory requirements7 ~ Yes [] No* Was the testing apparatus properly calibrated? 1~ Yes FiF1 N/AN°* For mechanical LLDs, does the LLD restrict product flow if it detects a leak? ~ Yes Fl No* For electronic LLDs~ does the turbine automatically shut off if the LLD detects a leak? ffi} N/A [] Yes U..J No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled " {~ N/A or disconnected? [] Yes [] No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoiing §ystem " ~ N/A malfunctions or fails a test? [] Yes [] No* For electronic LLDs, have all accessible wiring connections been visually inspected? . : :. t~ Yes [] No* Were all items on the equipment manufacturer's maintenanCe checklist completed7 * Itl the Section 1t below, describe how and when these deficiencies were or ~vill be corrected. It. Comments: Page 3 of 3 ~fitoring System Certification UST Monitoring Site Plan .............. ~/'nd~,,'~ ................................. , ~ '" ... . ..... Date map was drawn: Instructions If you already have a diagrmn that shows all required information, you may include it, rather than this page, with your Monitoring System Certification. On your site plan, show the general layout of tanks and piping. Clearly identi~ locations of the following equipment, if iustalled: ~nonitoring system control panels; sensors monitoring tank annalar spaces, sumps, dispenser pans, spill containers, or other seconda~ containment areas; mechanical or electronic line leak detectors; and in-tank liquid level probes (if used for leak detection). In the Space provided, note the date this Site Plan was prepared. Page __ of__ ,,, :Bakcrsfield,"CA :93308 ~Ph~661-327.9341 :Fax~661~325-~2559 ' ADDRESS: 370/ ~'. ~///¢ T~/,,"r~_.e.. LINE#2: ~;~'7~'~- - LICENSE NUMBER: ~90-1069 crrv, sx:Z~ e4r£ 'e/ LINE #3: TEST DATE: THE CONVERSION CONSTANT IS FOUND BY: (60 MIN/HR)/(3790/MIL/GAL) = 0.0158311 (MI'N/HR) (GAI~MIN) Divide the volume differential by thc test time ( 15 minutcs) and multiply by 0.0158311, which will convert thc volume diffcrcnfial from milliliters per minute to gallons pcr hour. The conversion constant causes the milliliters and minutes to cancel out. TEST VOL DIFF. PRODUCT TIME PSI START VOL (ML) END VOL OvtL) (ML) GPH GAIN/LOSS :PASS FAIL- ~ , 15':/.c ~¢o / q z I ,,¢ ~- 7 - --~ 0 7 " "'" COMMENTS: TEST VOL DIFF. PRODUCT TIME PSI START VOL (ML) END VOL (ML) (ML) . . . GPH GAIN/LOSS PASS FAIL ..... 5'7 u~- ! 5":'-/r 5-0 /(~, I..5"~/ 12 --.olz v COMMENTS: TEST VOL DIFF. PRODUCT TIME , PSI START VOL (ML) END VOL (ML) (ML) GPH GAIN/LOSS PASS FAIL COMMENTS: CVE Cal- Valley Equipment 3500 Gilmore Ave. Bakersfield, CA 93308 661-327-9341 FAX# 661-325-2529 VAPORLESS MANUFACTURING, INC. LDT-890 Leak Detector Test Record Contractor i Customer Date Locition - Product TeeMieian Submersible Pump Identification Manuhc~rer Model No. Serial Number Leak Detector Identffieation Manuhc~rer Description Other S~le Leak ' Piston-~pe ~ Tampe~-proof seal installed' Yes No ~' ; L~ak Detector in Submersible rnmp ~ Test at DisPenser 1. Operating Pump.Pressu[e~si (para. 15) 2. Gallons per hour rate i ~. 0 (para. 22). 3. Line pressure with pum~ shut ~ff II psi (para. 23): 4. Bleedback Test With pup off~: mi (para. 26) 5. 6. Leak detector stays in lek sea~ch position. (para.42) Ye~ ~ . ~ LEAK DETECTOR TEST ~ : P~ - ~ak detector fits test protocol F~il ~ ~ak d~tector fails test protocol Fall Fo~ 890C(9-1-96) ,.. *Complete the~al expansion test before failing ~eak detector,. 1996 Vaporless Manufacturing, Ine,i Prescott Valleyi AZ CVE Cal- Valley Equipment 3500 Gilmore Ave. Bakersfield, CA 93308 661-327-9341 FAX# 661-325-2529 VAPORLESS MANUFACTURING, INC. i LDT-890 Leak Detector Test Record Contractor Customer Date ' Locatidn ' ~ Product ,5'-2%0Z .TTo! ffeli, e T r£ ce ffalce, Eat. 3L. J ,Technician Submersible Pump Identification ..Manufacturer Model No, Serial iqumbei' ?., .. !..i'~... : Leak Detector Identification , Manufacturer ] Description ~ Other S~16 Leak D6toctbr .... ' · ! Dmphragm-type ' Tamper-proof seal installed? yes [ No i .il ~ ' ' ll . Leak Detector in Submersible Pump 1. Operating Pump Pressur~e ~-~ ' psi (para. 15) 2. Gallons Per hour rate , ,~ .~ (para, 22) 3. Line pressure with pump shut o:ff ~//'7t psi (para. 23) ! 4. Bleedback Tes{ with pump off, mi (para. 26) . : :: ',.!:" ' , 5. Step-through time to full:, flow ,~ seconds (para. 30) .. :;, 6. Leak detector stays in lefik search position. (para.42) Yes 'LEAK DETECIOR TEST Note: Fass ~ ~ ' test prot0co[ . Leak detector fits Fall = Leak detector fails test protocol Form 890C(9-]-96) *Complete thermal expansion test before fa/Hng leak detector. 1996 Vaporless Manufacturing, Inc., Prescott Valley, AZ 5-21-2802 ~.: 05PH FROH CALVALLEY EQU I P 16613252529 P. 2 CITY OF BAKERSFIELD OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (661) 326-3979 APPLICATION TO PERFORM FUEL MONITORING CERTIFICATION FACILITY t~.eY/4 ht?~3, ADDRESS 370/~ ,6v~//'e 7",~yf~c'~. ./ OPERATORS NAME f~/ NA~. OF MONrrOR MA~U~^CrURER TANK # VOLUME CONTENTS /, , ,/Z~', _ ~_?v~, . ~ IZ~ ~. , :3 ~ ,? _. u/~,-~ a,~- NAME OF TESTING COMPANy ~/-t/c/Fy £.q_vMm t.~c CONTRACTORS HCENSE~ 7gq/70~ HA ~. NA~ a PHO~ NUMBER OF CONTACT PERSON ~f~ ~1(~' 32 ~J~f. DATE & T~ TEST IS TO BE CONDUCED ~ C~Z~-03 /ff.'a0 APPROVED BY DATE SIGNAT~ OF APP~C~T ~ D /, May 21, 2002 FIRE CHIEF RON FRAZE John Havcrstock ADMINISTRATIVE SERVICES Cai-Valley Equipment 2101 "H" Street 3500 Gilmore Ave Bakersfield, CA 93301 CA 93308 VD,CE (661)326-3941 FAX (661) 395-1349 RE: Eepairs & Overfill to Fxisting Waste Oil Tank at SUPPRESSION SERVICES 2101 'H' Street I~errl High School District Transportation Department Bakersfield, CA 93301 VOICE (661) 326-3941 3701 East Belle Terrace #C FAX (661) 395-1349 Dear Mr. Haverstock: PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 This letter will confirm completion and compliance with regard to the waste FAX (661) 326-0576 oil tank at Kern High School District Transportation Department at 3701 East Belle Terrace #C. ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3979 On March 26, 2002, a system test was completed and passed. No further FAX (661) 326-0576 action is required. TRAINING DIVISION 5642 Victor Ave. Sincerelv, VOICE (661) 399-4697 FAX (661) 399-5763 Steve Underwood Fire Inspector/Environmental Code Enforcement Officer SBU/dc cc: Del Oliver, Kern Co. High School District II UNITED STATES STAL SERVICE ]~ First-Class Mail II Postage & Fees Paid USPS Permit No. G-10 · Sender: Please print you~ name, address, and ZIP+4 in this box ° ,~AKERSFIELD FiRE DEPART~.~ENT OFFICE OF ENVIRONMENTAL SERVICES 17~ 5 Che~t9r Av~ue, ~i~ 3~ 3sn S · Complete items 1, 2, ;. Also complete Date of Delivery item 4 if Restricted Delivery is desired, c.> !~-'~ 0"~- · Print your name and address on the reverse -- so that we can return the card to you. C. Signature · AttaChor on thethiSfrontCardif tOspacethe baCkpermits.Of the mailpiece, 'X [] Addressee D. I~ delivery addressta'~/f~rent from item 17 [] Yes 1. Article Addresse~l to: If YES, enter de~iv~-y address below: [] No DELL OLIVER KERN HIGH SCHOOL DISTRICT 3701 BELLE TERRACE #C , 3. Service Type BAKERSFIELD CA 93307 ~C, ertified Mail [] Express Mail [] Registered [] Return Receipt for Merchandise [] Insured Mail [] C.O.D. 4. Restricted Delivery? (Extra Fee) Fl' Yes ' I 7001 0360 0002 5244 6851 ~)S Form 3811, July 1999 Domestic Return Receipt ,, /. ~102595-00-M~0952 Postage $ ~. :~4~' Certified Fee 2. ].0 Postmark Return Receipt Fee ].. -~0 Here (Endorsement Required) Restricted Delivery Fee (Endorsement Required) Total Postage & Fees $ 3 o 94 sentr° D~'LL OLIVER ~;~';~';,'t:'~'~::, ............................................................................ or~'o'~,,x~Vo. 370! BELLE 1~]~J~,ACl~ ~C ............................................................................................... ,0 D May 13, 2002 Dell Oliver Kern High School District Transportation Department 3701 Belle Terrace #C Bakersfield, CA 93307 Certified Mail ~mE C,,EF NOTICE OF VIOLATION & SCHEDULE FOR COMPLIANCE RON FRAZE ADMINISTRATIVE SERVICES RE: Failure to Submit/Perform Annual Maintenance on Leak Detection 2101 "U" Street System at Kern High School Transportation Department, 3701 Belle Bakersfield, CA 93301 VOICE (661) 326-3941 Terrace #C FAX (661) 395-1349 Dear Mr. Oliver: SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 Our records indicate that your annual maintenance certification on your leak VOICE (661) 326-3941 FAX (661)395-1349 detection system is past due, May 8, 2002 PREVENTION SERVICES YOU are currently in violation of Section 2641 (J) of the California Code of 1715 Chester Ave. Bakersfield, CA 93301 Regulations. VOICE (661) 326-3951 FAX (661) 326-0576 "Equipment and devices used to monitor underground storage tanks shall be ENVIRONMENTAL SERVICES installed, calibrated, operated and maintained in accordance with manufacturer's 1715 Chester Ave. instructions, including routine maintenance and service checks at least once per Bakersfield, CA 93301 VOICE (661) 326-3979 calendar year for operability and running condition." FAX (661) 326-0576 You are hereby notified that you have thirty (30) days, June 13, 2002, to either TRAINING DIVISION 5642 Victor Ave. perform or submit your annual certification to this office. Failure to comply will Bakersfield, CA 93308 result in revocation of your permit to operate your underground storage system. VOICE (661) 399-4697 FAX (661) 399-5763 Should you have any questions, please feel free to contact me at 661-326-3190. Sincerely, Ralph Huey Director of Prevention Services by: Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services cc: Walter H. Porr Jr., Assistant City Attorney ,0 D April 12, 2002 K.H.S.D. TRANSPORTATION 3701 E. BELLE TERRACE BAKERSFIELD, CA 93307 Re: Enhanced Leak Detection Requirements REMINDER NOTICE FIRE CHIEF RON FR~E Dear Owner/Operator, ADMINISTRATIVE SERVICES 2101 "H" Street The purpose of this letter is to remind you about the new provision in California Bakersfield, CA 03301 law requiring periodic testing of the secondary containment of underground VOICE (6611 326-3941 FAX (661) 395-1349 storage ta_r~s. SUPPRESSION SERVICES 2101 "H" Street Your facility has been identified as not having secondary containment on at least Bake,slOe,d. CA 033O1 one of your underground storage tank components and as such falls under section vOiCE (661) 326-3041 FAX (661) 395-1349 2637.(1) of the California Code of Regulations, Title 23, Division 3, Chapter 16; PREVENTION SERVICES 1715 Chester Ave. As an alternative, the owner or operator may submit a proposal mad Bakersfield, CA 93301 workplan for enhanced leak detection to the local agency, by July 1, 2002; VOICE (661) 326-3951 FAX (661) 326-0576 complete the program of enhanced leak detection by December 31, 2002; and replace the secondary containment system with a system that can be ENVIRONMENTAL SERVICES 1715 ChesterAve. tested in accordance with this section by July 1, 2005. The local agency Bakersfield, CA 93301 shall review the proposed program of enhanced leak detection within 45 VOICE (661)326-3979 FAX (661) 326-0576 days of submittal or re-submittal." TRAINING DIVISION 5642 Victor Ave. Please be advised that there are only a few qualified testers available to perform Bakersfield, CA 93308 VOICE (661) 399-4697 "Enhanced Leak Testing". All testing must be under-permit through this office. FAX (661)390-5763 For your convenience, I am enclosing a copy of the code as a reference. Should you have any additional questions or concerns, please feel free to call me at (661)326-3190. Sincerely, Ralph Huey Director of Prevention Services Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SU/kr Enclosures r,.:' F' ~ ....-' - Ki.'-- - ']' '~"~T T __2~.'-;.'=;., l-"~-i '::: iii i .'"',¢~i-';~S':..; " ................................... --'"':-mff~'-'~"'-~-'-'"~"¢ .... RL"¢ i F.:L',? ;:' i R t'-':, f::. r'i 0 ;>-i: T 0 F.:"~';~':" t '..,--it.- "-., "..-,i ~ T E R 0 ',;' E R F T ............... i Fi L i .hi i T .h.-' 0 f--.." 0 THEFT ~Lr:i --~"-' ':' ~, ', = ,--, '":- *"-" '"-"-.., """ P'.- '-- .:.- '--' '-. ,','-" "" '-' ;'"" EXT, i .~'i P U T YEF; .'.-," ' '-'u f i ~ .,.z? .:, .-- c, ,:-: A ':: ..... ~- ,-' ...... '.-'-'~. .:--,-'--":- SEH '.,- ;iFi YL5 '; ,- .'-, =.. :. r' ._.. 5'.: ':.6 h'r".... ~ SE-:.'4W~TEr-- ..... '-':' ","~.'-; S E hi 0 U T ,.,.' c,:; ".-"" ~ '::: N i i '7 Ti .Qi,j ~.J ?,i .Q :] F ':: T ,'", .'-.' -' i ;z, _:- AA Ah1 ,- ,.,,,-'.,?, E F.:NAL ; ~' ........ ........ ,_' i',PUT RLHk'ra ENABLED ..qiiTF~ F'..':..'Tf.~T .-t: i :S,-':,,-',-,~, ~ ..... ........... ..- .-.-~.--,: i~ i ..'-I.. -'E'.: "3-8 R :"".:' j S E P, ::; 3 F.: ::.' 1 ':--_-: E f-~ s 0 R :.:l iT,] P,'z..'T NT : 2 .':.. .:,Lrl.:,d:. .d.~ --,Zi l L:;.Pi ?, i FTI ---:',-' -. .... "" . .:: b !'-I .':, U ~' .~ .,.21 ',', '.. ' / ' S E f.~;'._--; 0 R 6 A ,. ~i iTFI F'~' T P.;T .... ' ~ ':::F..'-'j i.'-' T T:.,.: .r- q T;.'-- ." ' ...... ~ ,-~;~"HL .-" L;H i L:~...'-'RU .." ~"'= i YAH..',( i ~ ............... ~ ' :~,',%'..~-.'-'i ; ::~ "- ;k' - - ',' ..... -= ........... ,...-_ i 0 '-""'"' '-'~"'-'"' .... .:--! l~.~..L *.. .-',;r:: ;..! . . HiGH :L:-'~TER LZHiT= ,--, .......... ~ :~ = E'.-' T F-:L-:.'-~'--':' i:i~ ::.-' ."-.~H.':_:::: ,_,,::..-~., iLL Li?,:iT: jJ '..qHr-:. 7 I..I ;' "'": '-': ;'-4 ~.: L-I !: .... I : ~. '~.R_ R_ 'r , ..-~ ~ .: .. '. ": ..:," '¢ - ~ I: L :_,:'~ ~ i ?,':i T: :'"' 2-~'-'.' E'." G A L :ii; G F..: 0 ::; ::; [ ~--~ r,.. ~ ...... ... ' fiA'H; FOL.qET~ -:-AH.KS, i .g c~ F; A '-' '-' --~ F.. :_! .:: .:: T,',='i ';'.'~ ~-r,, ' i-,r ..... ' .--~ .1..~M..' '" U A H K 2 i ::.' 0.2 :--~ G:R L '.ii;. G F.: 0 :--; S .,, ::~ F; ;q L :ii; '-' '-' '- ..... '-' '-~'~"-"-' HTF;N [d~YFF..' i ThiTY= · ~:,G a L :ii; G R 0 2 S ............... ,-. ;::', ."-='.' l N L: H .-5 ::; :.:q R i L.',.--.'. ~:, .q "':" L '.!!; r- .c, - ,--,-. '~: : ~ i .. :-: ---: .-: ~" .~!:.(.~..' L='.--' '-'-"~ '~'' F; R O !=; '.=; ~=- ~ -': L. -11, !"~ i..; :E' i-, ,_-' T · '.::¢%~ . _. ~ , '=.. ~,=~ .... . .... . .... :2,,-' "*'?,~ii'"' ' ' C:~'= ....... -' -' · .' ~:L-~ i"f'= iFi,i i ThiiT-- ~; .'- -" !-;RE:!!;i-;mr.,-.,-. "- 0 G A'L :_:.'. !.: ............ /f .. : .._, ,.~ ,.-: ._, ,. ........ , -' Fr' ,- ':":- : .:_.-_,~, i]Rb'.ii; ~ '~-";-'.'-"-: '-- Fl '.:-;., ~, -~,~,_._, L~ F.: "-":_. ._. .':; ,.-, , ..... L-; ...a. i ,:: G F-.: 0 '.:; '.:; ~ ..... i 5 ,?'~, i f',." U -"E '.=; · '"'.f ,'" .'" H ~- ~ '='" =' '-" '"' ~' c. ,-. - ........... :'-'-~G R i ::; ~-; F., ~-~ ,: ,: ........... "'-'-'i-:~ '"" ~- ....i ':: i-; mr-' ,'-'~ .-,'-' .-:"' :-, ....... . _ _ -. ,-- '. -~:' i-; R L '-:; I.~ b'. U 5-:, .. ~ ............. . -" ., c, W R L '.::; I_; ~'. U '.:; '.:; i ':-r.:-",.!~." '--: G'r~,F,:,:. 4 8 ~NC-"L~ES HATER :-~.H ~ 2; -' '--' -' ~[ .=' :-..-. ~ - ,-~ ..... ~;.'_--~ ,, E'..'~': "'"'~ '::' .."] E' F :; ::: 0 "/E R F Z L L '~'":-' .... .~' - ':_-' ,. · ' A ,e,-'...~ c. -.p,- ! S75 G.~i :::..' GROSS % ./.,. - '~: : L...j :-] i .. _ ~.~._~ =' '_~ .... _, .:, .:, ... . ~ i.. L-..'.-"-4 L. ~i ~ T Ei G R L i ;':. ,--'~ N F l C.; H ? C: A F' ..,;~ C Z T ",': ' ,z,:,ii Gi~L:i!; GRL]S::; i THEFT 6' G ~-'..' :ii; 't ~' ...'-,', c... q q q ,-4 ,-q g ~ L ::-"; G,-, 's'-' .:' i3 :- q R L :i!; z. ;_7;:~ , ' "-' ' ~-' '"' F~.. L .Z: Z: 0 G i:~ L :i!; F, F: L] :!_:; S ]) E L ' ',.,'..'-- ~-, '.,.' ~,,- I ,-.. ,,"-t. :-.n L"-_.,.' .'.-.l I.] '"' ' '-' .. r,~., , · -- .H L .::, !~ R L] L:; S i r, .--- ,' '~ t - ~ ." ..' i i'~. L-" i 'i.._ ~-, --'"" ,.::-i k] .... -:-" ~, ..'"_: ~..'--' ~ .-'-' T ~7,,: .... ' ' ',.-"4 '~.'--iGHT ([:RP~!_-:iTY: ~-"-:~,i4 U~! ::-'; ..":.,:., ,-: ,:- c. .. ;z, ::.] 4 F!I] ,"', i c. !]-' ;' A .-'., - - - · '--' ':- .... L--; S '-' '" ' '-' --' --'.~ H L .::, L~ h:U S.S E~ C-.' ~.~ ..."_ :ii; F-; R 0 :_--; S 0 G.4-' i' S · :; l/ e ,- ..... ,-.,-,,- .... · 'S',' C: ~ L :i:i" '-' - ..... ,_~ ~: L]S :--;"- ."-.~..": ~ i ,::- ,-. ~-, ,- ..... -. ,.-, G R !.L :ii; ~] r~, ,q :_--; :_-; , -"Rhii.:' ~-?;.~,,.',:-T~-..- ii :3/4 H.'-zGHT ....... ~,, .-"--, .:-n: ' :': ,GE i~-]P..~ fi; GRO::; - '- S -"'= F!LTiI T .i..i F. L4 D' ,-- ,, :~ I] R L ~:.; _. i i ....... ~'"-"'" ':' it '-' -" - C-:ROSS '7 A iq k' "- · ~ .-q G ¢:...' L ::i; F-' .c., ii S '._--; ~,LT AT~T~E.F.:: .,-.3GRL:!; CPF..':--;S 'q ~ i ~ · ' -' -- *. -' ."-'~' .~--~.'-.-~ %, i i.J-.:-qr,:. -- . ..... - .... ~ _. ;".~'.._--., ,- ,-. ,-. -'" -' '-' ' , '-', ,: ._, ."-'-! .." =,~ I [.; '.~J". :_, .-, .-, 'I r'-l...":: .-" ' '- ,"';--' HE i G,H CRPRC Z T"..,": ,':7 ,-' ,"-- i ,-- '-, ~, ~--:, L] F..' O.S S l' --..:, - --q G~L:_--; --p,-,,--,-- .... · ~ F~RL'-' L~Pn'--;3 .~.-~,-'-'-i ,-- !]r.,-~,_-;,_-.. -- ,~ H ,_ .:: . ..._. -_ ._- ~ . ':-:! _~H~.~., i ::; r. g, n ,-- ,-. SENSOR 5R FUEL .'.-"~E ~ ~L:~ k~ .-. r", - :-' l'-I .L?I :-' r~Hm ...z,~, ~ ....... 3 :- 22 PM FUEL :3 :: 5:2 P M .... SENSOR ALARM SENSOR 6A OPEN SENSOR MAR 26~ 2002 3:52 PM CAL-VALLEY EQUIPMENT 3500 GILMORE AVE (66t) 327-934'1 F~x: (661) 325-2529 Conl. ractor's Lic.ft 784t 70 A I-IAZ ,, '~For Review ~ Please Comment ~ Please Reply Urgotlt L'd 6CSCSC~L99[ dIOOB XB]]VA]VO NO~ NVOS:OL C00~-9C-~ D ____ February 11, 2002 KHSC Transportation FIRE CHIEF RON FRAZE - 3701 E Belle Terrace Bakesfield CA 93307 ADMINISTRATIVE SERVICES 2101 "H" Street Bakersfield, CA 93301 RE: Deadline for DisPenser Pan Requirement December 31 2003 VOICE (661) 326-3941 - ' m (681)395.1349 suPP.ESS,O. SE.V,CES R E M I N D E R N O T [ C E 2101 "H" Street Bakersfield, CA 93301 Dear Tank Owner: VOICE (661) 326-3941 unaergrouna storage FAX (661) 395-1340 PREVENTION SERVICES You will be receiving updates from this office with regard to Senate Bill 1715 ChosterAve. 989 which went into effect January 1, 2000. Bakersfield, CA 93301 VOICE 1661) 326-3951 FAX (661) 326-0576 This bill requires dispenser pans under fuel pump dispensers. On ENVIRONMENTAL SERVICES December 31, 2003, which is the deadline for compliance, this office will 1715 ChesterAve. be forced to revoke your Permit to Operate, for failure to comply with the Bakersfield, CA 93301 VOICE (661) 326-3979 regulauons. FAX (661) 326-0576 TRAINING DIVISION It is the hope of this office, that we do not have to pursue such action, 5642 Victor Ave. which is why this office plans to update you. I urge you to start planning Bakersfield, CA 93308 VOICE (661) 399-4697 to retro-fit your facilities. FAX (661) 399-5763 If your facility has been upgraded already, please disregard this notice. Should you have any questions, please feel free to contact me at 661-326- 3190. Sincerely, Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/dm CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3rd Floor, Bakersfield, CA 93301 FACILITY NAME ¥.~¢~,'~ ~l~.k ~'~,[ I~t~t~-ft~l,~. ~1t INSPECTION DATE II!~[0t Section 2: Underground Storage Tanks Program [] Routine ~ Combined [] Joint Agency [] Multi-Agency [] Complaint [] Re-inspection Type of Tank {30!~'C_.5 Number of Tanks ~ Type of Monitoring ~t-{'p, Type of Piping ~(O F OPERATION C V COMMENTS Proper tank data on file Proper owner/operator data on file Permit fees current Certification of Financial Responsibility Monitoring record adequate and current Maintenance records adequate and current / Failure to correct prior UST violations Has there been an unauthorized release? Yes No Section 3: Aboveground Storage Tanks Program TANK SIZE(Sf__B~, <lq_f) Oi( Jt-av~ ~ AGGREGATE CAPACITY Type of Tank Number of Tanks OPERATION Y N COMMENTS SPCC available L/' SPCC on file with OES Adequate secondary protection Proper tank placarding/labeling I,,/' Is tank used to dispense MVF? 'b/ If yes, Does tank have overfill/overspill protection? C=Compliance V=Violation Y--Yes N=NO Inspector: ;J~; dl~,_]~'_~--)~ Office of Environmental Services (805) 326-3979 Business Site Responsible Party White - Env. Svcs. Pink - Business Copy CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3ro Floor, Bakersfield, CA 93301 ADDRESS ,9}bO { ~. ~rlk {et-~¢t'_i PHONE NO. ~oqT- 3'a'of FACILITY CONTACT BUSINESS ID NO. 15-210- INSPECTION TIME NUMBER OF EMPLOYEES Section 1: Business Plan and Inventory Program [~l Routine '~ Combined [~ Joint Agency [~ Multi-Agency ~.] Complaint [~ Re-inspection OPERATION C V COMMENTS Appropriate permit on hand Business plan contact information accurate Visible address V Correct occupancy Verification of inventory materials ~./ Verification of quantities V Verification of location Proper segregation of material Verification of MSDS availability Verification of Haz Mat training Verification of abatement supplies and procedures Emergency procedures adequate Containers properly labeled V Housekeeping ~/ " Fire Protection Site Diagram Adequate & On Hand C=Compliance V=Violation Any hazardous waste on site?: ~] Yes ~] No Explain: LOfts'It:. 0,[ D August 3, 2001 K H S C Transportation Dept F..E C.,EF 3701 E Belle Terrace aoN ~a~ZE Bakersfield Ca 93307 ADMINISTRATIVE SERVICES 2101 'H' Street RE: Deadline for Dispenser Pan Requirement December 3 l. 2003 Bakersfield, CA 93301 ~Ax (66..~9s-1~9 R E M I N D E R N O T I C E SUPPRESSION SERVICES 2101 'H" Street Dear Ta~ Owner: Bakersfield, CA 9~301 unuergrounu ~torage VOICE (661) 326-3941 FAX (661)395-1349 You will be receiving updates from this office with regard to Senate Bill PREVENTION SERVICES 989 which went into effect January 1, 2000. 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 This bill requires dispenser pans under fuel pump dispensers. On FAX (661) 926-o576 December 31, 2003, which is the deadline for compliance, this office will ENVIRONMENTAL SERVICES be forced to revoke your Permit to Operate, for failure to comply with the 1715 Chester Ave. Bakersfield, CA 93301 regmauons. VOICE (661) 326-3979 FAX (661) 326-0576 It is the hope of this office, that we do not have to pursue such action, TRAINING DIVISION which is why this office plans to update you. [ urge you to start planning 5642 Victor Ave. Bakersfield, CA 03308 to retro-fit your facilities. VOICE (661) 399-4697 FAX (661)399-5763 If your facility has been upgraded already, please disregard this notice. Should you have any questions, please feel free to contact me at 661-326- 3190. Sincerely, Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/dm Cai Valley Equip~nt 3500 Gilmore A9"~.. Bakersfield, CA 93308 661-327-9341 FAX#661-325-2529 , Contractor's Lic. #784170 A HAZ Fax ~ U~ent ~or Review ~ Pl~as~ Comment ~ Please Reply ~ Ple3se Recycle GAL VALLEY EQUIPMENT ., 3500 GILMORE AVENUE BAKERSFIELD, CA 93308 661-327-9341 '~- FAX # 66t-3252529 CONT. LIC. ;;76¢170 TANK MONITOR INSPECTION DATE: S/8/01 ..... SITE: Kern Hi~lh School District 3701 East Bell Terrace Bakersfleld~, Ca 93307 MAKE; GIIbarco SOFTWARE VER. O1.O5 MODEL: Tank Monitor 3 SN: , ~31,608 ...... CONDITION OF UNIT:_ .Unit ope,rating properly ..at time ~of Inspection ........ TANK PROBES: QTY. 2 TYPE Cal~acitance LINE SENSORS: QTY. TYPE SUMP SENSORS: QTY. 2 TYPE FlOat Switch stTle ANNULAR SENSORS: QTY. 2 TYPE Steel Tank Sensors OTHER SENSORS: QTY TYPE PROGRAMMING ACCURACY & COMPLIANCE: READS ACCURATE TO TANK CHART? YES X NO POSITIVE SHUTDOWN? YES NO X COMMENTS: (3) TANK PROGRAMMING MEET COMPLIANCE? YES X NO PROGRAM INFORMATION: TANK DATA: MANUFACTURER OF TANKS? Joor Double Wall SIZE 12,000 - PRODUC1 Re~lular Unlea~l.e¢] , , SIZE 12,000 PRODUC'~ Diesel SIZE PRODUCT SIZE PRODUCT COMMENTS: INSPECTED BY: Bruce Hinsley DATE: ~ $18101 . / / / May 3, 2001 FIRE CHIEF, RO~ FR~E Mr. John Fox, Director of Maintenance and Operations ADMINISTRATIVE SERVICES Kern High School District Transportation Dept. 2101 "H" Street 3701 E. Belle Terrace #C Bakersfield, CA 93301 VOICE (661) 326-3941 Bakersfield, CA 93307 FAX (661) 395-1349 SUPPRESSION SERVICES Re: Annual Maintenance on Leak Detection System, Requirements for 2101 "H" Street Modification Upgrade Bakersfield, CA 93301 · .VOICE (661) 326-3941 FAX (661) 395-1349 Dear Mr. FOX: PREVENTION SERVICES 1715 ChesterAve. During a routine inspection conducted at your facility on November 16, 2000, Bakersfield~ CA 93301 ' VOICE (661) 326-3951 your annual maintenance certification was not found'during my inspection. FAX (661)326-0576 Mi-. Dell Oliver was supposed to forward me a copy. As of this writing, it has ENVIRONMENTAL SERVICES not been received. Please forward a copy to my attention as soon as possible. 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661)326-3979 During a meeting held with you on Wednesday, May 2, 200 l, I also brought up FAX (661) 320-0576 concerns with regard to conflicting data as to your underground storage tank TRAINING DIVISION , system and how Senate' Bill 989 will effect modification upgrades. As you are 5642 Victor Ave. ~aware, the City of Bakersfield Fire Department did not take over the Bakersfield, CA 93308 VOICE(661)399-4697 underground storage programs until November of 1991. This office relied FAX (661) 399-5763 heavily on documentation from Kern County Environmental Health as a basis for underground storage tank compliance. Having said that, there appears to be an inconsistency in what is documented in your file with regard to tank and piping components. Example (see attached copy) Form A & B, submitted to this office on January 28, 1992, indicates that Tanks #1 and #2 are double wall ~t~el clad with fiberglass reinforced plastic and double wall fiberglass pipe. However, Tank #3 (waste oil) indicates that you have a double wall steel clad with reinforced plastic, but your piping indicates cast iron pipe and a trench line. Records submitted on December 6, 2000 show that Tank #3 has double wall fiberglass piping. This could be just an error, but if it is not, it could have profoup4 effects on your upcoming modification requirements, as I will explain. Mr. John Fox, Director of Maintenance and Operations Kern high School District Transportation Dept. May 3,2001 Page 2 Senate Bill 989 which was signed into law on January 1, 2000 requires all underground storage tank facilities to install under-dispenser containment by December 31, 2003. It further states, that lined-pipe trenches used as a secondary containment must also be upgraded. The State of California does not recognize lined-pipe trenches as adequate secondary containment. One more point which I wish to make, if the piping on your waste oil tank is in fact steel and not cathodically protected; then, it doesn't meet current code and therefore must be taken out of service immediately. I truly believe, that this discrepancy is probably just an error. However, to be sure this office will require a third party certification from an independent contractor, who can verify what components are present in the system. Photo's during installation or verification of materials would also suff~ce as proof. Should you have any questions, please feel free to contact me at (661) 326-3979. Sincerely, Steve Underwood, Fire Inspector Office of Environmental Services SU/db Enclosures S:LMAY 200D John Fox Annual Main Leaks Sunde~wd Llr.wpd B D February 21,2001 John A. Leach FIRE CHIEF RON FROZE Leach & Leach 5314 Shaker Court ADMINISTRATIVE SERVICES Ca 93308 21Ol 'H" Street t~a~ersneia, Bakersfield, CA 93301 VOICE (661)326-3941 FAX (661) 395-1349 RE: Modification to Existing CNG Facility at 3701 E. Belle Terrace, Bakersfield Ca SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 Dear Mr. Leach: VOICE (661) 326-3941 FAX (661) 395-1349 With regard to CNG modification, this office, under Section 5204 (U.F.C. PREVENTION SERVICES 1715 Chester Av~. 1 997 Edition) Compressed Natural Gas/Motor Vehicle Fuel Dispensing Bakersfield. CA 93301 Stations requires the following: VOICE (661) 326-3951 FAX (661) 326-0576 Since you are fueling from both sides of dispenser island, you must have ENVIRONMENTAL SERVICES' 1715 ChesterAvo. signs showing "No Smoking," "Turn Off Engine" & "Emergency Shut Bakersfield, CA 93301 Off' placed on both sides of dispenser island. No other action is required. VOICE (661) 326-3979 FAX (661) 326-0576 Thank you for your help and cooperation in this matter. Should you have TRAINING DIVISION 5642 Victor Ave. additional questions, please feel free to call me at 661-326-3979. Bakersfield, CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 Sincerely, Ralph E. Huey, Director Office of Environmental Services by: Steve Underwood, Inspector Office of Environmental Services SBU/dm cc: John Fox, Assistant Director Maintenance & Operations January 22, 2001 FIRE CHIEF RON FRAZE rHSC Transportation Dept 3701 East Belle Terrace ADMINISTRATIVE SERVICES Bakersfield Ca 93307 2101 'H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 RE: Dispenser Pan Requirement December 31, 2003 Underground Storage Tank Dispenser Pan Update SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 Dear Underground Storage Tank Owner: VOICE (661) 326-3941 FAX (661) 395-1349 You will be receiving updates from this office now, and in the future with PREVENTION SERVICES regard to the Senate Bill 989, which went into effect January 1, 2000. 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661)326-3951 FAX (661) 326-0576 This bill requires dispenser pans under fuel pump dispensers. On December 31, 2003, which is the deadline for compliance, this office will ENVIRONMENTAL SERVICES be forced to revoke your permit to operate, effectively shutting down your 1715 Chester Ave. Bakersfield, CA 93301 fueling operation. VOICE (661) 320-3979 FAX (661) 326-0576 It is the hope of this office, that wc do not have to pursue such action, TR^IN~NG mm,ON which is why this office plans to update you. I urge you to'start planning 5642 Victor Ave. Bakersfield, CA 93308 now to retro-fit your facilities. VOICE (661) 399-4697 FAX (661) 399-5763 If your facility has upgraded already, please disregard this notice. Should you have any questions, please fee] free to contact me at 661-326-3190. Sincerely, Steve Underwood, Inspector Office of Environmental Services SBU/dm WI~EN MONITORING PRd~EDURES UNDERGROUND STORAGE TANK MONITORING PROGRAM This momtorm$ program must b~ ke~ at th~ UST location at all ~ Tim information on ,bin_ monilmin~ program ate condi~iom oftl~ opern~ing permit. The permit homer must no6ly the Offim of Envimnn~nl~ S~l~ic:~ within 30 day% of ~ ~ to th~ moaitolillg pro~ ~ ~ to ~ ~ ~ mal~g the ChnnSe. ~ I~/Sections 2632(d) and~ 2641(h) CCR. Facility Address 3"/~! f. l~/{,_ '~t',.~o,_. , Xo,.4,.. A. Describe the frequency of performing the monitoring: Tank d~ee~ Piping ~m ~3r~ rt oa ~ B. What methods and equipment, identitied by name and model, will be used for peffongng the monitoring: Tank ~_.~ 4,{/r~,rt~ Piping ~/--t~. &t{J)acc_o C. Describe the location(s) where the monitoring will be performed (facility plot plan should be attachedl: D. List the name(s) and title(s) of the people responsible for performing the monitoring and/or mah!.taininlLth~ equipment: E. Reporting Format for monitoring: Piping F. Describe the preventive maintenance schedule for the monitoring equipment. Note: Maintenance must be in accordance wit~ the manufacturer's maintenance schedule but not less than ev. eyy months. O. Describe the training necessary for the operation of UST system, including piping, and the' monitoring equipment: ~__ t,, .la ~-~, EMERGENCY RESPONSE PLAN UNDERGROUND STORAGE TANK MONITORING PROGRAM This monitoring program must be kept at the UST location at all times. The information on this monitoring program are conditions of the operating permit. The permit holder must notify the Office of Environmental Services within 30 days of any changes to the momtoring procedures, unless required to obtain approval before making the change. Required by Sections 2632(d) and 2641(h) CCIL Facility Name. ~_~vv~ t4t~/~ 5c[~oo{ O(~,d Facility Address ?"to l ~, tl~{{c l~rto, ct_, 5o,{-c ~ 1. If an unauthorized release occurs, how will the hazardous substance be cleaned up? Note: If released hazardous substances reach the environment, increase the fire or explosion hazard, are not cleaned up fi.om the secondary containment within 8 hours, or deteriorate the secondary containment, then the Office of Environmental Services must be notified within24hours. ~cot~{~t~, r~ "~r_. P{r_cd~oec. ~'~14'l~dn'~ ~' 5o[[].. 2. Describe the proposed methods and equipm, ent to be used for r, emoving and properly disposing of any hazardous substance. 3. Describe the location and availability of the required cleanup equipment, in item 2 above. 1 4. Describe the maintenance schedule for the cleanup equipment: 5. List the name(s) and title(s) of the person(s) responsible for authorizing any work. necessary under the response plan: ,30~.~x t~ra(cg, , 0~lk, l,[I tt/~r~_U CITY OF BAKERSFIELD OFFICE OF ENVIRONMENTOSERVICES · 17IS Chester Ave., Bakersfield, CA 93301 (661) 326-3979 UNDERGROUND STORAGE TANKS - UST FACILITY tYPE OF ACTION [] 1. NEW SITE PERMIT [] 3. RENEWAL PERMIT [] 5. CHA~ OF INFORI~a~TION (,~oec~y cltange [] 7. PERMANENTLY CLOSED SITE (Checl~ one gem on~y) ~, 4. AMEN{:)ED PERMIT /ocal u~e on/y) [] 8. TANK REMOVED [] 8. TEMPORARY SITE CLOSURE I. FACILITY I SITE INFORMATION I{.c~x ~h~k $¢~oo( /')L~4~'~c{. OLd" 000' 00103 NE,~qEST CROSS STREItT -- 401. FACILITY OWNER TYPE ' [] 4. LOCA'L AGENCY/OISmlCT' [] 1. CORPORATION [] 5. COUNTY AGENCY'° I'~'~. Lie? NON [] 2. ~ND~VIDUAL [] 6. ST^TE^GENC~ BUSINESS [] l. GAS STATION [] 3. FAJ:~M [] 5. COMMERCIAL TYPE [] 3. PARTNERSHIP [] ?. FEDERAL AGENcY° 402. [] 2. DISTRIBUTOR [] 4. PROCESSOR ~ 6. OTHER 403. TOTAL NUMBER OF TANKS L~ f~:ility on In¢~an Re~e~mlk3n ~ 'ff ov~er of UST a pul~lc agency, name or' supe~As~ or' REMAINING AT SITE tJ'ustlm'~ds? d/nAs~an, ~ ¢~' (:d~ce vd~,<:tt oge~ate~ No UST. PROPERTY OWNER NAME 407. ~ PHONE 406. MAILING OR STREET ADORE,~ 409. CITY 410. j STATE 411. J ZlPCODI= 412. PROPERTY OWNER TYPE [] 2. INOIVlDOAL ~, 4. LOCAL AGENCY / DISTRICT' [] 6. ST^TE AGENCY 413. [] 1. CORPORATION [] 3. PARTNERSHIP r-] 5. COUNTY AGENCY [] 7. FEDERAL. AGENCY TANK OWNER NAkE 414. I PI"IONE 415. MAILING OR STREET AD{~SS ' 41 417.I STATE 418. I ZIPCODE 419. c,TY ata tc( , &0 I ¢33o I TANK OWNERTYPE [] 2. INDIVIOUAL 1~ 4. LOCALAGENCYIDtSTRICT [] 6. STATE AGENCY 420. [] ~. CORPORATtON [-] 3. PN~q~ERSHI~ [] 5. COUNTY ^CENCY [] ?. FED~RJU. ^CENCY TYCi'K)HQ 4 4 ' 00~ 03 ~ Call{916)322-0ttO91fquestlonaar~se 4~. ~ND~CATE METHOO(S) ~ 1. SELF.~NSURED [] 4. SURETY 80ND [] ?. SLATE FUND [] ~0. LOCAL GOV'T [] 2. GU^RANTEE [] $. LEITER OF CREDIT [] 8. ST^TEFUND&C-POLr'~ ~eR [] 90. OTHER:. [] a. INSURANCE [] 6. EXE~nON [] S. ST^TE FUND & CO .22. · ' VI. LEGAL NOTIFICAIION AND MAILING ADDRESs C, hec~ o~'te ~ to Indicate whk:fl adds'esi stnouk:l be u~e<:l f~' legal n(Xlflcaflona an^ mailing. ~' 1. FACILrP( [] 2. PROPERTY OWNER [] 3. TANK OW~IER 423. Legel no0flcetlons and mailings will be senl Io the tank ouwm~ unlee~ box 1 ~ 2 II ct~ec~ed. vk Ar,r, UCA%Si~NATU.E ....... '~ '": NAME OF ^PI:I~(CAN'r (prinl) 426. Tm.E OF ^PPLIC^NT ¢27. STATE UST FACILITY NUMBER (For loc~ u~e only) 428. 19g~ U'PGRA~E CERTIFICATE NUMBER (For io<:al uae only) 42g. I UPCF (7/99) S:\CU PAFORMS~sw~cb-a .wpd (:~ICE OF ENVIRONMENTA~I~ERVICES 1715 Chester Ave., Bakersfield, CA 93301 (661) 326-3979 UNDERGROUND STOOGE TANK$- TANK PAGE L TANK DE~ 1 · ~-~ OFFICE OF ENVIRONMENTAL SER ._. 171S Ch~lter. Av~., Blkertfleld, CA 93301 (66TJ'326-3979 UNDER--UNO ~ A~VE~UND Pi~ SYSTEM ~PE ;~ESSURE ~ 2` SULTAN ~ 3. ~ 4~ ~ONSTRUCTiO~,~ ~. SIDEWALL ~ 3. LINEDTRE~ ~. OTHER ~ ~ ;. SINGLEWALL ~. UN~ ~NUFACTURER ~ ~UBLE WALL ~ ~. U~ ~ 2` ~UBLE WALL ~ ~. OTH~ ~FACTURER 461 ~UFAC~RER ~ I.~ESTEEL ~ 6. F~A~WII~~L ~ 1. ~ESTEEL ~ 6. F~ATI~EW/I~~ ~TER~S ~0 ~ 2` ST~NLE~ S~ ~ 7. ~V~D~EL ~ 2. STAINLESS STEEL ~ 7. ~V~D ~EEL ~RROS~N ~FI~R~ ~ 8. ~1~ (~) ~ ~. O~ER ~ 4. FIBER~ ~ 9. ~DIC ~TECTION ~ I. E~N~U~~R3.0~~O~~F~ ~ 1. E~~~OR3.0~~~W~O~FOR~ CONVENTIONAL SUCTION SYSTEMS: CONVEHTIORAL SUCTION SYSTEMS (Check ~/#mt appty): ~-] $. DAILY VISUAL MONITORING OF PUMPING SYSTEM + T~ P~ I~ I-~ S. ONLY VISUAL MONITORING OF PIPING ANO PUMPING SYSTEM TEST (0. I GPH) I-1 6. TRIENNIAL INTEGRITY TEST (0.1 GPH) SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIP~IG): SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIPING): [] ?. SELF MONITORING [] 7. SELF MONITOPJNG GRAVITY FLOW:. GRAVITY FLOW (Che~ al [] g. BIENNIAI. INTEC4~rTYTE~T(0.1GPH) [] S. DAILY VISUAL MONrFORING [] ~. mE~U. U~EGm'n' SECONDARILY CONTAJNED PIPING SECONDARILY CONTAJNED PIPING PRESSURIZED PIPING (Check all that aRoly): PRESSURIZED PiPING (Check ali That apply): ~ O. CONTINUOUS TURBINE SUMP SENSOR WTT'H AUO~BLE AND VISUAL ALARMS (Ch~ one) _ · 10. CONTINUOUS TURBINE SUMP SENSOR VWTH AUDIBLE AND VISUAL ALARMS AND (ch~ ~ne) [~"a. AUTO PUMP SHUT OFF WHEN A LEAK OCCU~ [] a, AUTO PUMP SHUT OFF WHEN A LEA~ OCCURS [] D. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM [] b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM DISCONNECTION DISCONNECTION 11.[] c, NDAUTO PUMP SHUT OFF . I-~ ¢. NO AUTO PUMP SHUT OFF AUTOMATIC LINE LEAK DETECTOR (a.0 Gtat. I TEST) WI'rH FLOW SHUT OFF OR I'~ 11. AUTOMATIOLEAK DETECTOR RESTRICTION [] ~2. At~UAL~NTEGRn'YTEST(0.t O~:~) EMERGENCY GENERATOR~ ONLY (C/~¢k M ~at a;Ngy) EMERGENCY GENERATOR~ ONLY (Chm~ I-] 14. CONTINUOUS SUMPSL=.N$ORWITHOUTAUTOPUMPSHUTOFF+ALKNBLEANO [~] 14. CONTINUOUS SUMP SEN~:)R WTT1-K)UT AUTO PUMP SHUT OFF + AUOIBLE AND VISUAL [] 15. AUTOMATIC LINE LEAI( DETECTOR (3.0 GPH TEST) W1THOUT FLOW SHUT OFF OR [] 15. AUTOMATIC LINE LEAI( OETECTOR (3.0 C4=H TEST) RESTRICTION [] 16. ANNUAL INTEGRfTY TEST (0ol GF~) [] 16. ANNUAL INTEGRITY TEST (0.1 GPH) [] 17. DAILY VISUAL CHECK [] I?. DAILY VISUAL CHECK Di$.r~r.N~ERCONTAINMENT I") 1, FLOAT MECHANI.~M THAT ~'IUT~ OFF SHEAR VALVE I-1 4. DAILYVISUALCHECK DATE INSTALLED 488 [] 2, CONTINUOU~ OI~EN~.R PAN ~EN~OR *AUOIBLE AND VI~JAL ALARM~ [-] 5. TRENCH UNER I MOHITORING ~-1 3. CONTINUOUS OI~=ENSER PAN ~EN~OR t&ITH AUTO SHUT OFF FOR OISPENSER* AUDIBLE AND VISUAL AJ.AIRM~ [~ ~, NONE 469 IX. OWNER/OPERATOR 81GNATURE I clrb(y ~ll t~e ~lo'mal[W~ p4'o'dd~cl hW il Itue ind ico.~'l~e to Ihe I~ll (M my knowtl(Ige. TITLE OF OWNERIOPERATOR 472 UPCF (7/99) S:~CUPAFORMS~SWRC~B.WPD · ~ '- s~?r~qn. 1715 Chester Ave., Bakersfield, CA 93301 (661) 326 3979 --' ~ '"--' UNDERGROUND STORAGE TANKS- TANK PAGE 1 LO~T~N DATE ~T~ OFFICE OF ENVIRONMENTAL · ' ~,~' 1715 Cheiter Ave., Blkerlfleld, CA 93301 (661T326-397g U~T, T~ p~ r UNOER~U~ ~ ~ A~VE~UNO PlP~ SYSTEM CONSTRUCTIO~ ?. SI~EW~L ~ 3. UNEDTRE~ ~. OTHER 4~ ~ I. SI~LEWALL ~. ~NUFAC~RER~ 2. ~U~E WALL ~ ~. U~ ~ 2. ~U8LE W~L ~ ~. OTH~ * ~ ~UFACTUAER 461 ~UFAC~RER ~ ~TER~S ~0I~ 2. ~T~ESS 9~EL ~ T. ~V~D ~EL ~ 2. STAINLE~ STEEL ~ 7. ~V~D ~EEL CORROSION CONVENTIONAL SUCTION SYSYEM~ CONVENTIONAL SUCTK)N SYSTEM~ (Check ~/ghat I--] 5. OAILY V~SUAL MONffORINO OF PUMPJNG SYSTEM + TR~NNLM. P~P~G k~'EGRJTY I--~ $. DAJLY V~SUAL MONITORJNG OF PII~N(3 ANt) PUMPING SYSTEM TEST (0.1 GPfl) ~J 6. TRIENNIAL II~n'EGR~'Y' TEST (0.1 GPH) SAFE SUCTION SYSTEMS (NO VACVES IN BELOW GROUNO PIPING): SAFE SUCT]ON SYSTEMS (NO VA/.V~S IN BELOW ~UNO P~PING): [] 7. SELF MONrrOR~NG I"1 ?. SEU: GRAV~Y FLOYd. GRAVTTY FLOW (Check al b~a! apply): [] 9. B~ENNL~.~NTEGRF/YTESY(0.10F,.i) [] 8. DAJLYV~SUALIMONiTORJNG f-! 9. mF.~e;L~.WTEGRrrYTESY(O.t GPH) ~.ONDN~Y co~rNNED P~qNO SECONDARJLY CONTNNED ~S~O ~ (~ M Mt ~' ~R~D ~ (~ d ~t ~): ~ ~) · ~o. ~;~us ~ ~ ~R ~a. A~O~OFF~A~~ ~ a. A~O~OFF~A~~ ~ b. A~O ~ ~ O~ FOR ~. ~ FNLU~ ~ ~S~ ~ b. A~O ~ ~ OFF ~R 01~N ~ c ~AUTO~~ ~ ~ ~A~O~O~ ~ 1. A~O~T~ LI~ ~ ~ (~.0 ~ ~ ~ ~ ~ OF~ OR ~ 11. A~O~ ~ ~R ~STRIC~N 12. ~1~~(0.1 ~) ~ 1~ ~1~~(0. I ~) 13. ~US~~*~~~ ~ 13. EMERGENCY OENERAI'OR~ ONLY (Cheat M M ;~,~; EMERGENCY OENERATOR~ ONLY (Check M bls! apply) C~ 14. CONTINUOUSSUI~aSF. N$OR WITHOUT AUTO PUMP SHUT OFF ) AUOIBI.E ANO I-] 14. CONTINUOUS SUMP SENSOR WTTHOUT AUTO PUMP SHUT OFF + AUOIBLE ANO VISUAL VISUAL N.ARMS ALARMS I--] 15. AUTOMAT]C UNE LEA~ DETECTOR (3.0 GJaH TEST) WtTHOUT FLOW SHUT OFF OR I-1 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) RESTRICTION ["] 16. ANNUAL INTEGRITY TEST (0.1 Cd=H) [~] 16. ANNUAL INTEGRITY TEST (0.1 GPH) [] 17. OAILY VISUAL CHEC~ r'] 17. OAILY vISUAL CHECK OI~PF. NSERCONT)dNMENT [] I. FLOAT MECHANLSM THAT ~RJTS OFF SHEAR vALvE [] 4. DAILY VLtUAL CHECK DATEIH~TALLED 488 [] 2. CONTINUOUS OLIPENSER PAN SENSOR * AUOISLE AND VISUAL ALARM$ [] $. TRENCHUNER/MONJTORING [] 3. CONTINUOUS OISPENSER PAN ~NSOR wrrH AUTO SHUT OFF FOR 01SPENSER * AUOIBLE AND V1SUAL ALARM8 ~'~ 6. NONE IX. OWNER/OPERATOR SIGNATURE NAME OF OWNERK)PERATOR (j~n0 47 ! Trr~E OF OWNER~OPERATOR 472 UPCF (7199) S:[CUPAFORMS~SWRCI~.B.WPD ,~ ' ' O'PFICE OF ENVIRONMENTAL"~ERVICES a~,?r~qrr 1715 Chester Ave., Bakersfield, CA 93301 (661) 326-3979 --'~ UNDERGROUND STORAGE TANKS- TANK RAGE 1 ~]* t T~K DE~ DATE I~T~ (Y~) - CITY OF BAKERSFIELD · O~FIC~ OF ENVIRONMENTAL SERVIt / ' ~ 1715 (=hooter Av~,, Blklr~flelcl, CA 93301 (6817'526-3979 UNDERGROUND PIPINO AI)C)VEGROUNO SYSTEM TYPE ;, ~ESSURE ~'2. ~UCT~N ~, ~VI~ 4~ CONSTRUCTIO~ ~' 51~E W~L ~ 3. LINED TRE~ ~ ~. OTHER 4~ ~ ~. SI~LE WALL ~ ~. UN~ ' ~NUFACTURER ~ 2. ~U~E WALL ~ ~. U~ ~ 2. ~UBLE WALL ~ ~. OTHER ~FACTURER 461 ~UFAC~RER I.~ES~ ~ 6. F~A~I~~L ~ 1. ~ESTEEL ~ 6. F~ATI~EWII~~ ~TER~S~O ~ 2. ~TN~ES~ ~EL ~ 7. ~V~D~EL ~ 2. STAJNLE~ STEEL ~ 7. ~V~D ~EEL CORROSION ; ~ ~OTECT~N ~ ~ 3. ~IC ~A~ ~ ~ ~ ~. U~ ~ 3. ~STIC ~ATIBLE ~ ~S ~ 8. ~ (H~) ~ ~. O~ ~ 4. FI~R~S ~ e. ~ (~) ~ ~. O~ER ~ 4. FIBER~ ~ 9. ~OlC ~TE~ION ~ 5. ~ELWI~ATI~ ~ 9. ~O~~N ~ ~ 5. STEELWlCOATING ~. U~ 4. U~R~U~ ~ ~UND ~E~R~O ~ (~ M ~t ~): ~UR~D ~ (~ ~ ~t ~): ~ ~. E~N~ U~ ~ ~OR 3.0 ~ ~ ~ ~O ~ ~ ~ FOR ~ ~M F~ ~ ~ ~~*~~ S~ F~U~ ~ ~ ~~N + ~ ~~ ~ Z ~Y0;~ ~ 3. ~~~(0.~) ~ 3. ~~~(0.t~ ~ 4. CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS (Chec~ all that apply): J--J S. DAILY VISUAL MONITORING OF PUIbEqNG SYSTEM + TRIENNIAl. PiPiNG INTEGi~TY r'J 5. OAILY VISUAL MONITORING OF PIPING A,NO PUMPING SYSTEM TEST(0. t Ca~) I-i 8. TRIENNU~NTEGRrrYTEST(0.1 SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUNO PIPING~ SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIPING~ r-] 7. SELF MONITORING · r""l ?. SELF MONITORING GRAVITY FLOW GRAVITY FLOW (C,~,ecka~t~atapp4,): [] $. BIENNIALINTEORITY~(0.1 C.-~H) ~] 8. DAJLYVISUAI. MONITORING r-I 9. BIENNL4LtNTEOR~TYTEST(O.t ~EOONOAR~Y CONTJMNED PIPIN~ ~ECONDARJLY CONTAJNED PIPING PRESSURIZED PIPING (Cl~ck M ~hat apl~y): PRESSURIZED PIPING (~ ~11 that appty): (~ ~) I 10. CONTINUOUS TURBINE SUMP SENSOR W~ AUDIBLE AND VISUAL ALARMS AND (cheg~ a. AUTO PIJMP SHUT OFF WHEN A LEAK OCCUF~ [~ a. AUTO PUMP SHUT OFF WHEN A lEAK OCCURS D. AUTO PUMP SHUT OFF FOR LEAY~. SYSTEM FAILURE AND SYSTEM [] b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM DISCONNEC'I'X~N DISCONNECTION [] c. NO AUTO PUMP ~ OFF [] c. NO AUTO PUMP SHUT OFF ~ 11. AUTOMATIC LINE I. EAK .DEI~-GTOR(S.0GPt4TEST)WITHFLOWSHIITOFi=OR [] 11. AUTOMATIC LEAK DETEC'FOR RESTRICTION n 12. N~NUALU~TEGRrrYTE~r(0.1 ePH) [] 12. ANNU~;NTEGRr~TESY(0.1 [] t3. CONT1NUOUSSUMPSENSOR*AUOIBLEANDVlSUN, NARMS ri 13, CONTINUOUS SUMP SENSOR + AUOflttE AND VlSUN. N,~,qMS EI~!RGENCY OENE~ATOR~ ONLY (Cheok ~ 15. A~O~C~E~E~OR~.0~~~OFFOR ~ 15. ~O~TICLINEL~D~E~OR(3,0~ RES~IC~N ~ ~6. ~NU~ ~E~ ~T (04 ~) ~ 1~. DAILY~E~ ~ 17. DAILYVISU~ECK ~ 3. ~I~S Ol~ ~ ~E~E~T~ 81GNA~RE ~ Tff~ OF O~E~TOR UPCF (7/99) S:~CUPAFORMS~SWRCi~B.WPO -' CERTiFICATiON OF FINANCIAL RESPONSIBILI~ Fn~ii,y Nan~ Fs, a'iitydqddrem ~ O[4~d - Ld,nl Apuy Ceph.- ~',~ill~.(.) · f~l~ltJ~ ~ eltra ~ ~ ~at~ my ~ Ilst~ ~ ~ fo~; therefore · s~rate carttfl~te lo ~t r~i~ for e~ site. 0~ B. ~ ~ Y~~ -FutL ~ of either the tank o~r or the ~rator. r~JbJll~ either es c~tai~ in the f~i ~tatJ~,. ~ CF~, Pert ~, S~r~ H, S~i~ 280.90 throb 280.103 (S~ Filial R~JbJtl~ ~i~, for M ~ I~ - LIst ail ~ ~ ~r~ses of c~J~ ~or f~ivJ~is JoauJ~ cMrage. or file ~r es J~ica~ ~ ~ or ~. (if ~i~ Sta~e Cie~ F~ (State F~) le8~ bL~.) M ~ ' i~tcnte ~ of coverage for ea~ t~ of ~h~J~s). If ~ th~ ~ ~ ~f~ - r~fcace the effusive daceCs) of att finalist ~mi~Cs). CState F~ cMroge ~td ~ c~ti~ 8s t~ 8s y~ nifltaJfl c~ti~e ~. r~in eLigibLe to ~J~ ~ * l~tcate y. or ~. Does the s~JfJ~ fJ~J8L ~mJm pr~J~ c~age for ~tim third Mrcy c~aciofl? (if ~i~ State F~, f~icece ~".) O. FKItI~ - Provi~ att f~tiCy ~/or sics ~s e~ lMtJm E. Sl~m lt~ - Pr~J~ sigMture ~ ~ce sig~ ~ co~ wr or ~rator; print~ or ~ ~ ~ title of t~ ~r or ~ritor; stgMture of uiC~l or ~Ce~ ~ si~; ~ princ~ or ~ ~ of uitn~s or Mca~ (if MCo~ sJ~ ~ p~eese ptKe ~ta~ seat next to ~ca~s ~here to bit CerClflcRJon: Ptene send original to your Local ogemy (.gemy .ho issues your UST pemJts). Keep i copy of the certification at each facility or site Listed on the form. Quasi, ictuS; if you hive questions on financial reslx~sibiticy requirements or on the Certification of Financial Ilesponsibf.tit¥ Fonu, please contact the State UST CLeanup F~ncl aC (916) 739-Z47S. Note: pefleltfee for Failure to ~--qtv tilth Ffnaflctel' ~fbliicy Ilmuirem~s: FaiLure to comply my result in: (1) Jeoperdiziflg claimer eLigibiLity for tho State UST CLeenul2 FuYI, end (Z) Liability for civil ponitclel of up to SlO,O00 doLLars per day, per undergrould storage tank, for each day of viotation as stated in ArticLe ?, Section 2S299.76(s) of the California IleoLth and Safety Code. CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3rd Floor, Bakersfield, CA 93301 FACILITY NAME i~.r~ ~,a.t~ ~¢[~00[ ~0k~{. TC0.1tt,q INSPECTION DATE tt~k[OtO Section 2: Underground Storage Tanks Program [~l Routine 'I~ Combined [~l Joint Agency [~l Multi-Agency 1~1 Complaint 1~1 Re-inspection Type of Tank ~0,) ff-C ~ Number of Tanks ."5 Type of Monitoring ~/,.//IA. Type of Piping 4~'}_ Ill 1¢ OPERATION C V COMMENTS Proper tank data on tile Proper owner/operator data on file Permit tees current Certification of Financial Responsibility Monitoring record adequate and current ~/ Maintenance records adequate and current Failure to correct prior UST violations Has there been an unauthorized release? Yes No Section 3: Aboveground Storage Tanks Program TANK SIZE(S) AGGREGATE CAPACITY Type of Tank Number of Tanks OPERATION Y N COMMENTS SPCC available SPCC on file with OES Adequate secondary protection Proper tank placarding/labeling Is tank used to dispense MVF? If yes, Does tank have overfill/overspill protection? C=Compliance ,.~V=Violation Y=Yes N=NO ~p~ Inspector: ~}or,~....~ j~7~.,~ ~ ...... Office of Environmental Services (805) 326-3979 Business Site Responsible Party White - Env. Svcs. Pink - Business Copy ~'~'~~A ~ Bakersfield Fire Dept, ~ H~IF_.ARDOUS MATERIALS DIVI~,ON ~. 2130 G Street, Bakersfield, CA 93301 (805) 326-3970 UNDERGROUND TANK QUESTIONNAIRE~ RECEIYED JA~ 2 ~ 1992 . I. FACILI~/SlTE No, OF TANKS 3 DBA OR FACI'LI~ NAME ~ NAME ~ OPERATO~ gERN HIGH S~HOO~ DISTRICT ~ ~ERN HIGH SCHOO~ ADDEE~ N~EEST CEO~ S~RE~ PARCEL No.(OPHONAL) 3701 E. BE55E TERRAC~ SUIT~ C ~T. VERNON SEC. 4 T30S R289 CIW NAME S~A~E ZIP CODE BAK~RSF[gSD CA 93307 ~ BOX TO INDICATE ~CORPORATION ~INDIVIDUAL ~PARTNERSHIP ~tOCALAGENCYDISTRICTS ~COUN~AGENCY ~ STATE AGENCY, ~FEDEEAEAGENCY WPE OF BUSlNE~ ~ l GAS STATION ~ 2 DISTRIBUTOR KERN COUNW PERMIT EMERGENCY CONTACT PERSON (PRIMAE~ ' -' EMERGENCY CONTACT PERSON (SECONDAR~ option01 DAYS: NAME (~ST. ~IRS~ PHONE No. WI~H AREA CODE DAYS: NAME (~S[ FIRS~ PHONE No, WITH AREA CODE SEYKORA~ BEN (805) 631-g~99 BAN~STON~ BUD (805) NIGHTS: NAME (~S[ FIRS~ PHONE ~. WI~ AR~ CODE NIGHTS: NAME (~SL FI~ PHONE No. WITH AR~ CODE BANKSTON, BUD (805) 393-0308 SHEARER, JIM (805) 5flg-61f16 [m. PROPER~ OWNER mNFORMAT[ON (MUST BE COMPLETED) NAME CARE OF ADDRE~ INFORMATION [ERN HIGH SCHOO~ DISTRICT TRaNSPORTaTION . . MAILING OR STRE~ ADDRESS ~ BOX ~ INDIVIDUAL O LOCAL AGENCY 3701 ~. BE~EE T~RAC~ SUITE C ~o~,a~c~ ~,~.~,s~m ~cou,~c~ Q~a~c~ ' CIW NAME STATE ZIP CODE [ PHONE No. WITH AREA CODE B~gRSFIgED C~ 93307 [ (805) 631-3199 III. TANKOWNER INFORMATION (MUST BE COMPLETED) NAME CARE OF ADDRESS INFORMATION KERN HIGH S~HOO~ DISTRICT . MAILING OR STREET ADDRESS ~ BOX ~ INDIVIDUAL ~ LOCAL AGENCY ~ STATE AGENCY 3701 ~. BgLEE TERR~C~ SUITE C ~O~,~c~E Q,~,m~,s.m ~cou.~mc~ CIW NAM~ ~ ZIP CODE PHONE No. WITH AREA CODE OWNER'S DATE VOLUME PRODUCT. IN TANK No. INSTALLED STORED SERVICE I ' 6-7-89 ~ UN-T-z'I~A-I~I~-I~-~ GASOLINE ~ N 2 6-7-89 1 2,000 DIESEL ~ N 3 6-7-89 1 ,000 DRAIN OIL ~ N Y/N Y/N Y/N DO YOU HAVE FINANCIAL RESPONSIBILITY? (~N' TYPE SELF INSURED SCHOOLS OF KERN ,t~F-.,~ANK O ESCRIPTION COMPLE~ ALL ITEMS - SPECIFY IF UNKNOWN IlL TANK CONSTRUCTION ~ ~PE OF ~ ~USLE WA~ ~ 3 S~ WA~ Wl~ E~ER~R LINER ~ 95 UN~OWN SYSTEM ~ 2 SINGLE WA~ ~ 4 SECONOA~ ~NTA~NMENT (VAUL~OTAN~ ~ ~ O~ER B.. TANK ~ 1 ~RESTEEL ~ 2 STAINLESS S~ -~ 3 FIGERG~S , ~ STEELC~O WIFIBERG~REINFORCEDP~C MAT~R[~ ~ 5 ~NCRE~ ~ 6 ~LWlNYL CHLORIDE ~ 7 ~UMINUM ~ 8 1~. ME~ANOL ~MPATIBLEW~RP C. ~ERIOR ~ 5 ~ L[N(~ ~UNLIN~ ~ ~ UN~WN ~ ~ O~ER UNING ~ MNING MATER~ ~MPA~ ~ 1~ M~? YES~ NO~ O. CORROSION ~ 1 ~L~LENE W~ ~ 2 ~A~NG ~ ~ ~ ~ ~ FIBERG~S REINFORCED ~C PROTE~ON, ~ S ~ODIC.PRO~TION ~ 91 ~NE ~ ~ UN~WN ~ ~ O~ER IV. PIPING INFORMA~ON mRC~ A IF~O~GROUNOOR U IFUNDERG~UND, BO~IF~L~A~ A. SYS~M~PE A ~ 1 SUC~ON A~ 2 PRESSURE k ~ ~ G~V~ A ~ ~ O~ER B. CONSTRU~ION C. MA~RIAL ANO A ~ 1 ~REST~L A U 2 STN~ESS S~ A ~ ~ ~L~ ~LORIOE~(P~)A~4 FISERG~S PIPE CORROSION A ~ 5 ~UMtNUM A ~. 6 ~NCR~ A ~ 7 ST~LWI~A~ A U 8 1~ M~OL ~MPA~B~W~RP PROTE~iON A ~ 9 ~VANI~D S~ A ~ '10 ~OiCPRO~C~ON A ~ ~ UN~O~ A ~ ~ O~ER D. LEAK O~ECTION ~TOMA~CLINE~D~CTOR V. TANK LEAK D~ECTION I. TANK DESCRIPTION COM~.~r~ ALL ITEMS - SPE¢IF'Y IF UNKNOt,'~fl OWNER'STANK '. 0.' ) C. DATE iNSTALLED <.OOAY'EAR} [ -- ?- ~? } O. TANK C~ACIW IN ~ONS: Ii VD O {11. TAN K CONSTRUCTION aARK O.~ ~m~ ONLY [. ~OX~S ~ ~. AN0C. ~O ALL mA~ AP~S ~. ~OX O A. ~PE OF ~ ~UaLE WA~ ~ 3 SINGLE WA~ WI~ E~ERIOR LINER ~ 95 UN~OWN SYSTEM ~ 2 SINGLE WALL ~ 4 SECONDARY CONTAINMENT (VAUL~DTAN~ ~ ~ B. TANK ~ I ~RE STEEL ~ ~ STAINLESS S~ ~ 3 FIBERG~S ~ STEEL C~D WI FIGERG~ RE~NFORC~ P~C MATERIAL ~ 5 CONC~E~ ~ 6 POL~INYL CHLORIOE ~ 7 ~UMINUM ~ ~ 1~. ME~A~OL COMPA~BLEW~P UNING ' IS UNING MATERIAL ~MPATIBLE ~ 1~. ME~ANOL ? YES~ NO~ D. CORROSION ~ 1 ~LYE~LENE WRAP ~ 2 COAT~NG ~ 3 ~t WR~ ~[BERG~S REINFORCED P~STIC PROTECTION ~ 5 CA~OOIC PROTECTION ~ 91 NONE ~ 95 UN~OWN ~ g~ O~ER IV. PIPING INFORMATION cmc~ A IF ABOVE GROUND OR U IF UNDERGROUND. BO~ IF APPLICAB~ A. SYSTEM~PE ~ ~ I SUC~ON A U 2 PRESSURE A~3 GRAVIW A U 99 O~ER B. CONSTRUCTION A U I SINGLE WA~ A U 2 ~UBLE WALL. A~3 LINED TRENCH A U g5 UN~OWN C. MA~RIAL AND ' A U 1 ~REST~L A U 2 STAINLESS S~EL A U 3 ~L~INYL CHLORIDE (PV~A U 4 FISERG~S PIPE '. CORROSION A U 5 ~UMINUM A U 6 CONCRE~ A U 7 STEELWlCOA~NG A U 8 ~/. ME~ANOL COMPA~BLEW/FRP PROTE~ION A U 9 ~LV~I~D S~ A U 10 CA~OQICPRO~CTIQN ' A U 95 UNKNOWN A~99 O~ER D. LEAK D~ECTION ~ I ~TOMATiC LiNE LEAK DE~CTOR ~ 2 LINE T~H~ESS ~S~NG ~ ~NffOR~NGINT~S~T~L ~ 9g O~ER ' V. TANK LEAK D~ECTION March 29, 2000 K.H.S.C. Transportation Dept. 3701 East Belle Terrace Bakersfield, CA 93307 Dear Underground Tank Owner: Your permit to operate the above mentioned fueling facility will expire on June 30, 2000. However, in order for this office to renew your permit, updated forms A, B & C must be filled out and returned prior to the issuance of a new permit. Please make arrangements to have the new forms A, B & C completed and returned to this office by May 15, 2000. For your convenience, I am enclosing all three forms which you may make copies of. Remember, forms B & C need to be filled out for each tank at your facility. Should you have any questions, please feel free to contact me at (661) 326-3979. Sincerely, Steve Underwood, Inspector Office of Environmental Services SU/dlm Enclosure D February 9, 1999 F~E C.,EF Kern High School Dist Trans Dept RON FRAZE 3701 Belle Terrace ADMINISTRATIVE SERVICES Bakersfield, CA 93309 2101 'H" Strut Bakersf'mld, CA 93301 VOICE (~05) ~26-~94~ ~Ax (805) 395-1349 RE: Compliance Inspection SUPPRESSION SERVICE~ Dear Underground Storage Tank Owner: 2101 'H' Street Bakersfield, CA 93301 VOICE (805) 326-3941 FAX (805) 395-13~9 The city will start compliance inspections on all fueling stations within the city limits. This inspection will include business plans, PREVENTION SERVICES underground storage tanks and monitoring systems, and hazardous 1715 Chester Ave. Bakersfield, CA 93301 materials inspection. VOICE (805) 326-3951 To assist you in preparing for this inspection, this office is ENVIRONMENTAL SERVICES enclosing a checklist for your convenience. Please take time to read this 1715 Chester Ave. eakerstleld, CA 93301 list, and verify that your facility has met all the necessary requirements to VOICE (805) 326-3979 be in FAX (805) 326-0576 compnance. TRAINING DM$1ON Should you have any questions, please feel free to contact me at 5642 Victor Ave. Ba~ers.o~,~, c^ 9~3oe 805-326-3979. VOICE (805) 399-4697 FAX (8O5) 399-5763 Sincere/y, Steve Underwood Underground Storage Tank Inspector Office of Environmental Services SBU/dm enclosure BAKERSFIELD FIRE DEPARTMENT February 13, 1998 fiRE CHIEF MICHAELR. KELLY Kern High School District 3701 East Belie Terrace ADMINISI~a~"IVE~ Bakersfield, CA 93307 2101 *H° Street Bakersfield. CA 93301 (805) 326-3941 FAX (805) 395-1349 ~J~ smac[s RE: "Hold Open Devices" on Fuel Dispensers 2101 'H' Street Bake~fletdo CA 93301 C805) 326-3941 Dear Underground Storage Tank Owner: FAX (805) 395-1349 n~nmoN ~mcra The Bakersfield City Fire Department will commence with our annual 1715 Chestet Ave. Underground Storage Tank Inspection Program within the next 2 weeks. Bakersfield. CA 93301 (805) 326-3951 FAX C805)3264)576 The Bakersfield City Fire Department recently changed its City Ordinance concerning "hold open devices" on fuel dispensers. The Bakersfield City Fire ENVII1ONMENT, AI. ~ 1715 Chestef Ave. Department now requires that "hold open devices" be installed on all fuel i~o~flo~, CA 93301 dispensers. The new ordinance conforms to the State of California guidelines. (805) 326-3979 FAX (805) 326-0676 The Bakersfield Fire Department apologies for any inconvenience this TRAINING DIVISION 5642 VIctor Street may cause you. Bokersltetd, CA 93308 (805) 3994697 FAX(805) 399-5763 Should you have any questions, please feel free to contact me at 326-3979. Sincerely, Steve Underwood Underground Storage Tank Inspector cc: Ralph Huey BAKERSFIELD FIRE DEPARTMENT January 5, 1998 REE CHIEF MICHAEL R. KELLY ADMINISTRATIVE SERVICES 2101 'H' Street Bakersfield, CA 93301 (80,5) 326-3941 FAX(80S)~S-1349 Mr. John Fox Kern High School District SUPPRESSION SERVICES 3701 East Belle Terrace 2101 'H" Street Ba~ers,~, ca9~l Bakersfield, CA 93307 (805) 326-3941 FAX (8O5) 395-1349 ............ RE: ..... 501 'South'Mt. Vernon PREVENTION SERVICES 1715 Chester Ave. Dear Mr. Fox: Bakersfield, CA 93301 (805) 326-3951 FAX(~) ~26-05z6 This office would like to acknowledge with great appreciation your letter ENVIRONMENTALSEI~.qcES dated Decembe_r 29, 1997. Our records indicate that your tank was removed in 1715 Chester Ave. July of 1997, and a closure letter was sent on July 25, 1997. Our records show BakersfielcL CA 93,301 C805) 326-3979 this tank permanently closed and no further action is required. FAX (805) 326-O576 This office would like to apologize for any inconvenience our error may TRAINING DIVISION 5642 Victor Street . . have caused you. ~l~lkersfielcl, CA 93308 (805) 3994697 FAX (80~) 399-5763 Hazardous Materials CoordinatOr Mr. Ralph E. Huey Hazardous Materials Coordinator Bakersfield Fire Department 1715 Chester Avenue, #3 Bakersfield, CA 93301 Dear Mr. Huey: . _ In response to your letter dated December 18, 1997 regarding underground storage tanks becoming illegal to operate, please see attached correspondence dated July 25, 1997 from Howard H. Wines, III, Hazardous Materials Technician, along with a copy of Notices of Completion from Wegener Construction wherein the tanks at the Regional Occupational Center and West High School have been removed.' We trust this information will permit you to close your files on this matter; however, should you have any questions, or require any further information, please do not hesitate to contact me. Very truly yours, John Fox Assistant Director Maintenance & Operations /Ur cc: Walter Grainger JUN-14-~G FRI 14:03 KHSD TRaNSPORTaTION DEPT FaX NO, 806 398 7042 TO: FROM: ~ ~ ~ ~z~iF..S INCLUDIN~ COV'F~ SHEET. BAKF. RSFI;~ r~. CA 95~,0'~ ' JUN-14-96 FRI 14:04 KHSD TRaNSPORTaTION DEPT FaX NO. 805 398 7042 P, 02 0~/11/~99~ 10:188~$~-421~ I:;L~ KERN Hi~.'H SCHOOL DISTRICT MA.'[NTENANCE & OPERATIONS ~7~)I ZA,"~? BELLE TERRAC-Z, SUITE A BAKF,.qSFI ELD ,. CA 93307 ~CCORDI!~G TO OUR RECORDS YOUR LEAK DETECTION ,~,E~ WAS INSPECT~D AND FOUND TO ~g IN CO~5IANCE 1995 CALENDAR YEAR. CG~T~'.~CTOR'S /,iC~N~: ~Z94074 B A K E R S F I H L D Cove]' Sheet CALIFORNIA Bakersfield Fire Dept. Office of Environmental Services 1715 Chester Ave. · Bakersfield, CA 93301 FAX No. (805) 326-0576 · Bus No. (805) 326-3979 Today's Date do/~<-,/q ~ Time / 7.'~ No. of Pages COMPANY: FAX No: ,~ ?~ - FROM: ,~,~/~ '-~",e ~ Bakersfield Fire Dept. · Office of Environmental S'e~ices CCR, TITLE 23, DW~~ CHAPTER 16, UNDERGROUND STORAGE TANK REGULATIONS~ AImCLE 3. N~W UNDERGROUND STORAGE TANK DESIGN, CONSTRUCTION, AND MONITORING REQUIREMENTS 2630. General Applicability of Article (a) The requirements in this article apply to owners of new underground storage tanks. Underground storage tanks installed after January-1, 1984, may be deemed to be in compliance with the requirements in this article if they were installed in accordance with federal and state requirements that existed at the time of installation. However, the applicable repair and upgrade requirements in Article 6 shall be complied with. (b) Sections 2631 and 2632 specify design, construction, and monitoring requirements for all new underground storage tanks. New underground storage tanks which store only motor vehicle fuels may be constructed and monitored pursuant to the requirements specified in sections 2633 and 2634 in lieu of those specified in sections 2631 and 2632. However, if the tank is constructed according to requirements in section 2633 the monitoring requirements of section 2634 shall also be met. (c) All new underground storage tanks, piping, and secondary containment systems shall comply with sections 2635 and 2636. (d) All monitoring equipment used to satisfy the requirements of sections 2632, 2634, and 2636 shall be installed, calibrated, operated, and maintained in accordance with manufacturer's instructions, including routine maintenance ~ and service checks (at least once per calendar year) for operability, or running. condition. Written records shall be maintained as required in section 2712 of Article 10. Authority,: Health and Safety. Code 25299.3, 25299.7 Reference: Health and Safe~ Code 25281, 25291, 40 CFR 280.20 2631. Design and Construction Requirements for New Underground Storage Tanks (a) All new underground storage tanks including associated piping used for the storage of hazardous substances shall have primary and secondary, of containment. Primary containment shall be product-tight. Secon0ary containment may be manufactured as an integral part of the primary, containment or it may be constructed as a separate containment s.vstem. (b) The design and construction of all primary containment including any integral secondary containment system, shall be approved by an independent testing 3-1 7902.6.5.3-7902.6.15.2~ 1994 UNII=OI~tFIRE. CODE 1. Have an alarm which provides an audible and visual signal when the quantity of liquid in the ( tank reaches 90 percent of tank capacity, 2. Automatically shut off the flow when the quantity of liquid in the tank reaches 95 percent of tank capacity, or 3. Reduce the flow rate to not more than 15 gallons per minute (0.95 L/s) so that, at the reduced flow rate, the tank will not overfill for 30 minutes, and automatically shut-off flow into the tank so that none of the fittings on the top of the tank are exposed to product due to overfilling. 7902.6.6 Inventory control. Daily inventory records shall be maintained for underground stor- age tank systems in accordance with Section 5202.3.9. 7902.6.7 Locations subject to flooding. Where a tank could become buoyant due to a rise in the level of the water table or due to location in an area that is subject to flooding, the tank shall be anchored in place. See Appendix II-B or manufacturer's installation inslxuctions. 7902.6.8 Leaking tanks. Leaking tanks shall be promptly emptied and removed from the ground or abandoned in accordance with Section 7902.1.7.4 or 7902.1.7.2.4, respectively. 7902.6.9 Used tanks. Reinstallation of used tanks is allowed when such tanks comply with the requirements of Sections 7902.1.8 and 7902.6.15. See also Section 7902.6.16.4. 7902.6.10 Tank lining. Steel tanks are allowed to be lined only for the purpose of protecting the interior from corrosion or providing compatibility with a material to be stored. Only those liquids tested for compatibility with the lining material are allowed to be stored in lined tanks. Tank opening, cleaning, preparation, inspection, lining, closing and testing shall be in accord- ance with U.F.C. Standard 79-6. For permits to alter a tank, see Section 105, Permit f.3.6. Interior-lined underground tanks shall be protected from corrosion in accordance with Section 7902.6.15. 7902.6.11 Secondary containment. An approved method of secondary containment shall be provided for under~ound tank systems, including tanks, piping and related components, where a leak from such a system would pose an immediate hazard to persons or property, as determined by the chief. See Appendix II-G. 7902.6.12 Leak detection required. Underground storage tank systems shall be provided with an approved method of detecting leaks from any component of the system which normally contains liquid. 7902.6.13 Leak-detection installation and maintenance. Leak-detection devices and methods shall be in accordance with nationally recognized standards. See Article 90, Standard u.3.2. Such devices shall be inspected and tested at least annually, and the test results maintained for at least one year. 7902.6.14 Leak reporting. Any consistent or accidental loss of liquid, or other indication of a leak from a tank system, shall be reported immediately to the fire department. 7902.6.I5 Corrosion protection. 7902.6.15.1 General. Underground tanks and piping shall be properly designed, installed and maintained, and protected from corrosion in accordance with Section 7902.6.15.2 or 7902.6.15.3. EXCEPTION: If conditions, based on adequate proof, warrant the deletion of the corrosion-protection requirements, the chief may waive the corrosion-protection requirements. See Article 90, Standards a.3.10, n.l.2, s.l.l.u.l.14 and u.2.1. 7902.6.15.2 Cathodic protection. Cathodic protection systems provided for corrosion protec- tion shall be in accordance with nationally recognized standards. 1 --ggR , JUN-OS-98 NED 14:19 KHSD TRi~NSPORThTION DF. PT FhX NO, 80B 398 '/042 P, O1 t~~m6H $CHOOI~ DIS'~GT f, TR POg TIO D~PAR~I~ DATE: PA6ES I~CLUDLN6 COV~-._~ JUN-05-96 NED 14:20 KHSD TR~qNSPORT~TION DEPT FA× NO, 805 398 7042 P, 02 UNDERGROUND STORAGE TAi~K INSPECTION ~:.: Bakersfield Fire Dept. Bakersfield, CA 93301 FACILITY NAME . ~0,~g_ ~ BUSINESS_I.D. No. 215-00o FACILITY ADDRESS ~7Oi ~ gq [g ~ggff CI~ ~~,~L ZIP CODE FACILI~ PHONE NO, ~ ~ t- ~ t~ , ~ ' ~ ........ ~1 ,~ INSPECTION DATE ~~~ , . ~u~ [~ , TIME IN .TIME OUT ~,~.~ '~ INSPECTION ~PE: ~ ~ ~~~ ........ ~n~ ~te ~.~t ~ ROUTINE ~,, ~ FOLLOW-UP ~, ~ t m~ REQUIREMENTS y~ no ~a ~ m la. F~ A & B Subm~ ~" , ld. State Sur~e Paid ........ ~ ~ ~ 1[~ W~ ~tr~ ~ists ~en ~ & O~ t00~e UST ' .., I~ ~. Appr~ W~ R~ne Mon~g P~e ~ ~. Tank Integd~ Test ~ La~ 12 M~t~ ~~ ~, Pr~ Piping 1~ T~t in La~ 12 ~n~ I. ~ _ ~. S~ion Piing T~h~ T~.in La~ 3 Yearn ~. G~i~ F~ PIpin~ ~gh~ Te~in ~ 2 Y~m ~ ~. Test R~u~ SubmiR~ WRhln ~ ~ / ~. Annual Invent~ R~ilati~ S~t~ent Su~ ~ ~. Met~ Cal~at~ Ann~lly / 5. W~ Mahdi Tank ~gi~ R~ for ~mll Ta~ ( ~ / ~- 7. ~h~ ~o~t~ank ~uging R~u~s ~ ~ ~ 10. Continuo~ Int~t~l Monitoring f~ Daubl~Wall~ Tan~ / ' - 11. M~an~l Line Leak Det~ors ' / 1~, E~tr~ Li~ Leak ~t~ / 14. AUtOmatic Pump. Shutoff ~pa~3i~ 15. Annual ~int~ance/~li~t~n of L~k Det~ Equip~t ~ ~ ,~ 6. Leak D~ Equ~ent and Te~ ~th~ ~t~ in LG-113 ~ ~ ~' '" 17. W~Ren R~ Main~in~ ~ SRe ~ 18, Re~R~ Chang~ in U~g~dltions to O~ting/~nit~ng Pr~ures of UST ~em Wi~in ~ ~ ~ 19. Re~ Una~ Re~ ~in 24 H~ ' ~ ~, Approved UST S~t=m Repairs ~d U~md~ / ~. 21, ,., R~s S~ ~th~ Pmt~i~ In~n ~ RE-INSPECTION~ _~ _. ~ ~ JUN-05-96 WED 14:20 KHSD TRfiNSPORTfiTION DEPT FaX NO, 805_398 7042 P. 03 ., KEBN COUNTY ' ENVIRONMENTAL HEALTH SERVICES DEPARTMENT CONTINUOUS MONITORING DEVICE DALLY INSPECTION FORM II IIII I II III IIII I III ~OWER A~ DATD TiM~ INIT. TA~ ~ ON/OFF ON/OFF COMMENTS III I IIIII I I IIII I , ~ . . . .~ ,~,; ...... , ~,~ , , * ,,. · ~ ~ ~.~.' ..;.-¢ ¢ ..¢ .... ,...,.. JUN-O6-96 NED 1~:21 KHSD TRhNSPORT~TION DEPT F~× NO. 80~ 398 70~2 P, 04 OG/OS/199G 14:88 885-I :lQ RLW EQUIP P/~'iE OG ~.' . .. $,4~ BETTERAV1A ,SUITE ~ ~ SANTA ~RIA, CA 93455 ~~ BAKERSFIE~, ~ 93~07 · PHONE ~34-1100 P.O, BOX 6~ ?-K M' $ D TRANSPORTATlfJN 17;8 ~ S87~tI 370! EAST BELLE TERRACE STE C PER J~Fl R~'T'ESTEO UNIT f"~ S'rEg UNLE~D~O AND ~OUNO SA~ ~'.ESLJCTS I , INSTALL,,~U NEW CHECK VALVE IN UNi. EADtED S'FSTEH A~O TESTED FUR k.p,.RE C, DPERA'F) gN 2 O2Lg~3B i~lB3 5 5HECK V&LV~ ¢~.~;; : .:z,',lt~,,:;,.,'~,:.~."j:~.~::,'' ,ur-- .,... · ..... , .. , ,, ~ · , , , ·, . .... ^. , ;,'~.,'¢~.~'9~ ~,~:t:.: ..~ ,-'.~r-~ '., ,, ...... ~ %~' ,s' ".r ' , .%.,~ ~.~.'~ ~.~ ~i;..'jt~,~' '""'~'~: J?~.,::~:~v:. ' ~'~'~" ~' '~' $~" ) ' ' ...."~ ..... " ' :' ' ':' "' ...... ' ' ' ' ~ "" . ,~,~-, ~, ~.~ ~:~.'~ ..~,; ,:.::: . ~., ~,~%.. ,,..:~,,,~ } ' h~'~,~C' .'" ~ ~'~T,-' ~"~"~ '. ':' ' '~' '~''~ ........ ~'~* ~'.~ "~' ~,~ .. ,...,,~ vm, ~.w:,~' ~ ~ ~H'q,~' .~' ,'~ ............ ',.: ,~ ·: .. '.r.', ' -,'r~ ~ .... . :~&~ :;~r,~.:}.. t~ ~ 9~. ~-~2~ ,,,r..~ ~,.: .:,~U¢.:,.,, .,. ~',-~¢ '% ~,~,~....,.. ~XqDF..,m,~m~.A ~.,~ ~,~,..,..:~.~.. ~ .... . ~,, ~T~':'''~ '''''~'~'''' ..~.,,~ .... : ...... ,~,,:9;~.<. ,.. :,~,~ ..... ,, ,~ "~,':t)~ '..:Z~.~.,;~'' ".~:,~?~," kAeO~ ~ ,~ Oo i S~, MZLEA~: iD 5~00 sUPPL, IES~ ,, ~ SALES TAX: 1.95 PLEASE PAY FROM THIS INVOICE ~R~: N~ 30 DAYS '. JUN-OB-96 NED 14:21 KHSD TRaNSPORTaTION DEPT FaX NO. 805 398 7042 P, I~$/05/1995 14:88 $0~-8~:~215, ; 2080 SO. U~ON A~. AUTOMOTIVE - INDUS~IAL PETROLEUM EQUI~M~T'INgTAL~TION - MAINTENANCE L r '~OA OFFICE · . ,,, :.. · ..... Sub Oontract .... ~'" [ Re~tal,' JUN-05-@6 WED 14:22 KHSD TRhNSPORThTION DEPT Fh× NO, 805 398 7042 P, 06 06/05/1~6 14:0B 805-B3~ RLW £~UIP F~z ~a MEM~I~R Ellb BRANCH OFFICE ,~.3 BETTERAVIA SUff~ ~ ~ANTA MARIA. CA 93455 I80SJ g2~.1135 ~RO~M 2080 SO~H UNION ~tLINO ADDRESS EQ~ME~ BAKERSFIELD, CA 93307 · PHONE B34-I 1~ P,O, BOX 640 IN~A~ - ~I~NCE CAUF. CON~AOORS L~. · 294074 BAKER~IELD, CA 93302 J'--tK H S g TRA.NSPORTA'FIO~ TR~NSPORT~TIDN O~P~TM~NT C~01 EAST SELLE TERRACE STE C BAKERSFIELD 2~005~ kO20OO V~PBRLESS PIs'FaN 285.00 . .';j] ,',~,,'~;~,~-"..,.';".?. ,;.....; , ,-~ ,.~, ~, ,~'..' ;.;.,..:~ ,-. ....,..< . . . . .... ... , ,..: . ,..~, "-.,)"~?'t:'.,s. ';'-' " "~ ',' '"' ';- ~,'" '.' ,. · '" ' ' ', "'1 "'~' · t, , .'":';"~"-'~-; ~'::. &,'x,~/~'~,~-4-" '.,¢'~; ',.: :';', ~,,~.'~..'...." ,, ,, ..... ~..; ,,~, ."' :. ':,' ,', .,~,' ...'&',("'.' · · ~-~;~.":i~ ;"~ "'-': ":" ......... ' .................................... ', ~' "-'?'J'J?W'j'~ ..'. 5.,'.'..:...~..:~"'*"'~.':;-';".'P' ;'~'!. 'J'- '- ,'-;',' . ...... ,,:.. · '." ;' '-' ';.' .. ~.:-2.,, '.., '" .' .:~,-.-~., · ',,Z,?.?j..:.. ,....,,.~. ,~ "-.-~,',r I ,., '-.'~.~ -~,~ ~ 'u,.'"-' '":'""'- '-':' '" "~:"'"' ' ,""'"*' ":: ~"' ; ,,~i...,:~; .~. .;.,~.,;.". ':. '" ? .:;'.' .~ ",'c'.?::.".7- ' <" '~.';-' ~ ;;.;::... .. .,, ,, ,, ~'~. .'.:,,..;-'.' . ~ ,~...:.s.~. :,:...:,~:.,..- ,,,,,..;,- , .. ,~;..'. '.':...~,',.-~ .,.~,~,)~:.?;- ., .,~,m;-,e. ~".::.,. '; :.". ,:,', ..:.L.'?...; ' ?,'...;':' ;~'%~;:""':";'~;~,~,:'.~';:'; ~'-~."q:?/.. ;,::...~\.T' 'F "-',' ':<"'; .... ;-..'::;'~' · i/. -"-.¥. .... ,,"-;',~?.},'~';'....~"..5 ,,~,~(:.~.;.~. . ,,....:..:; ,;, ,., .....'.-. ,:. ,.,, ;,2, ;'t (..~. ;.u ', ,~;,,,.,=~-~.-.~:. ,~','~ ;~,,.., >:; ....... .:.,: ,, . .,.~,..:, .., ,, ;.:...<,¢;~..-~ :¢ . ~:..u,',.'~',,.,...~....,,.; .... .~-.¢-,. <.-;~?.~.~ ~'~. ~.-: ?:: ~, ,? .:.,. ~ ,v..,~,;... ;,,,~:.~;..~,.?, :,.,~';'~' -.-. ............. ~. ,~ . ~.:. . .,.,,; ~.~,~, '...:j~.~l~.~_. ,~,.~,~.'. . LF~,~ l ..SO ,~ · ~, ~ ~L;PPL I ~,S: 5 T L.; 39i.. 26 PLEASE PAY FROM THIS INVOICE TERM,S: NET 30 DAYS . ::...-. ,, r4LE COPY JUN-05-96 HED 14:28 KHSD TR~qNSPORT~TION DEPT F~× NO, 805 ~98 7042 P, 07 BlOOmFIeLD, (,os)e~-~ ~ gER~ICE INVOICE A~OMOTIVE - INDUSTRIAL P~ROLEUM EQUIPMENT INSTAL~ON - ~INTENANCE ~ur. 1131 12~ ' .... _ _ ,. c~.~, c~.~ i . . , ~.vo~c~ B~ke~field, ~1 ifo~ni~ To AOdT 17 18 0 ~ ~ ............. ~ o~c~ ~ QTY. P~T NO. Haza~ous Waste - F;na~e Oha~ ~ 1 ~ aef M~I~ REMI~TO ~.o, sox ~o JUN-05-96 NED 14:23 KHSD TRANSPORTATION DEPT FA× NO, 805 398 7042 P, 08 · B6/OS/l~3~J6 14:~ 885-8~, ~1~ ~W E~IP ~ ~ MEMBER ~, m 543 B~ERA~A SUITE F E~' (805l ~18~I ~ 35 ~~T B~ERSFIE~, CA 93307 . PHONE 834.~ 1 O0 P.O, ~X 640 ~~ON ' ~~N~ C~F. CO~~S L~, · 294074 BAKERSPiELD, CA 93302 · ~ ~t ~J ~ I 02/06/96 ~AK~S;IEL0 CA 93Z07- E UELL, E 'T'ERRP,; ....... 'T~ST ~ ~N~S AND CW~CKE~ FOR SLOW PUMPS, ALL ~OLi~D WIgES ON L~BOR: i -50 60,90 TOTRL: ~ OO PLEA~ PAY FROM ~lS INVOICE ~S: N~ 30 DAYS JUN-O~-@6 WED 14:24 KHSD ?RRNSPORTATION DEP? FAX NO, 80~ 398 7042 , _..~P, O~ AUTOMOTIVE - INDU~RIAL P~ROLEUM (806) 928-1135 EQUIPM[NT INSTAL~TION - MAI~NANCE ~UF. CON*~aCTO.S uc. ~o. ~o*~ ~,. ~NVO[CE NO. OFFICE ONlY S Q~. ~ OESC~I~ON ~LE~ PAY F~O~ NVOIC~: ~.~s,,e~ ~,e u~, .~,~t PLEASE RLW gOUIPM~I F~snce Cha~e ~ ~per M~ffi REM~ TO ~.o. sox UNDERGROUND STORAGE IK. INSPECTION .... .. _lli:.i .... '-'.,-'Ba. kersfield Fire Dept. Bakersfield, CA 93301 FACILITY ADDRESS ,~7t51 '"~..~[~_-'~e-~,A0,g-__ CITY ~A~x,e/~J~.,o~XC~k ZIPCODE FACILITY PHONE No. ~, ,'~ I= J~ I~ ~ ID~ ID~ INSPECTION DATE ~"j'~-~-/"~'/,~ <~ ~, Product . Product . Producl TIME IN TiME OUT ( iL. &,~,o/',.~ ~:~ ~ t.~A~'<:O "7~[ d4 t~ ~,. :,'-I o~--.~ Inst Date Inst Date Inst Date- INSPECTION TYPE: .~",,'~ _.~7~_~,e.~,"~,.. Size Size size ROUTINE ,//' FOLLOW-UP 1~, ~ r""~O REQUIREMENTS yes no n/a yes no n/a yes no n/a la. Forms A & B Submitted ., ~,. I' 1 b. Form C Submitted .~ ~ 1 c. Operating Fees Paid :'/ ~ ld. State Surcharge Paid ; ~ 1 e. Statement of Financial Responsibility Subm?ed,, ~ lf. Written Contract Exists between Owner &/Operator to Operate UST ,,-' 2a. Valid Operating Permit ~ 2b. Approved Written Routine Monitoring Procedure ,,,'" ~,.-' 2c. Unauthorized Release Response Plan ~ 3a. Tank Integrity Test in Last 12 Months ~" 3b. Pressurized Piping Integrity Test in Last 12 Months ~" 3c. Suction Piping Tightness Test in Last 3 Years,, ~" t,,," 3d. Gravity Flow Piping Tightness Test in Last 2 Years "'"' 3e. Test Results Submitted Within 30 Days ~ 3f. Daily Visual Monitoring of Suction Product Piping- . ..... I,~ 4a. Manual Inventory Reconciliation Each Month ~' 4b. Annual Inventory Reconciliation Statement Submitted ~,- 4c. Meters Calibrated Annually ~' 5. Weekly Manual Tank Gauging Records for Small Tanks [ _,,/' ~ 6. Monthly Statistical Inventory Reconciliation Results!~,~-~ ~ ~ ~-" 7. Monthly Automatic Tank Gauging Results h~ {1 ~'~' '""' 8. Ground Water Monitoring..~ ~,~ ~"' 9. Vapor Monitoring ~ 10. Continuous Interstitial Monitoring for Double-Walled Tanks ~' 11. Mechanical Line Leak Detectors ~ 12. Electronic Line Leak Detectors ~ 13. Continuous Piping Monitoring in Sumps ~ 14. Automatic Pump Shut-off Capability ~, 15. Annual Maintenance/Calibration of Leak Detection Equipment ~.~. ~ 16. Leak Detection Equipment and Test Methods Listed in LG-113 Series ,~ ~' ,'~ 17. Written Records Maintained on Site ~" 18. Reported Changes in Usage/Conditions to Operating/Monitoring Procedures of UST System Within 30 Days t~,~! ,~_ ~-,-~' 19. Reported Unauthorized Release Within 24 Hours ~ ,.,~' 20. Approved, UST System Repairs and Upgrades ~" ~/ :,-.- 21. Records Showing Cathodic Protection Inspection ~ ~,~ 22. Secured Monitoring Wells ,,-'-- 23. Drop Tube f ~''/' ,.~ RE-INSPECT ON DATE ~ ~ ,/, -~c4'i:.~, ,, ,,, OFFICE TELEPHONE No. INSPECTOR: -~- x~ VD 1669 (rev. 9/95) %CI Ooz'. " . ERN HIGH $CHOOI ISTRICT -~ ,\~].,]]~c'~. Fred L. Starrh. President ~ .*~lli~ ~//~ DaSd C. Crenshaw. Vice President J. B~an Batey, Clerk ~ ~ Sandra V. Se~o Con~e Wattenb~ger ~ THOMAS N. ~ON~S, Ed.D., SUPeRINTeNDeNT 2000~EN~-FOU~TH STREET · 8A~E~SFIELD · ~ALIFO~NiA · ~0~ · (805)~a~-a~00 · F~: (805)~-~ D~. NEAL W. OLSEN Febma~ 24, 1995 ~0 s~p.,.,~,. ~ Ralph E. Huey Hazardous Materials Coordinator City of Bakersfield 1715 Chester Avenue Bakersfield, California 93301 ... This letter is in support of the use of the Underground Storage Tank Cleanup Fund to demonstrate financial responsibility for taking corrective action and/or compensating third parties for bodily injury and property damage caused by an unauthorized release of petroleum in the amount of at least $1,000,000 per occurrence and $1,000,000 annual aggregate coverage. Underground storage tanks at the following facilities are assured by this letter: Kern High School District - ROC Kern High School District 501 S. Mt. Vernon Ave 3701 East Belle Terrace Bakersfield, Califomia Bakersfield, California A copy of the District's 1993/94 audited financial statement is enclosed. I hereby certify that the wording in the first paragraph of this letter is identical to the wording specified in subsection 2808.1 (d)(1), Chapter 18, Division 3, Title 23 of the California Code of Regulations. ' I declare under penalty of perjury that the foregoing is true and correct to the best of my knowled/~and belief. · ~ xecu~B ~ ~ E akersfield,~a n February 24, 1995. ¥) (Chief Financial Officer) AN AFFIRMATIVE ACTION/EQUAL OPPORTUNfFY EMPLOYER "WE CARE" .-.... .' January 30, 1995 FIRE DEPARTMENT 1715 CHEb"TER AVENUE M.R.,E"Y WARNING! FIRE CHIEF 328-3911 CERTIFICATION OF FINANCIAL RESPONSIBILITY REQUIRED 215-000-001038 KERN HIGH SCHOOL DIST TRANS DEPT 3701 E BELLE TERRACE C >.-.~AKERSF I ELD, CA 93307 Dear Underground Storage Tank Owner: Our records indicate that your business does not have a Certification of Financial Responsibility on file with this office. Please forward either a copy of your existing State approved mechanism to show financial responsibility or else complete the attached Certification of Financial Responsibility form. An attached letter from the State Water Resources Control Board lists the approved financial responsibility mechanisms required to pa.y for corrective actions resulting from leaking underground fuel tanks. Remember, most tank owners only have to show financial responsibility for at least $10,000 of olean up liability. The Underground Storage Tank Clean Up Fund (USTCF) may be used as the mechanism to cover the remaining accidental release liability. The total amounts of financial responsibility required (check boxes from section A of form) are aa follows: If you don't sell product from you tanks, and you pump less than 10,000 gallons per month, check "$500,000 per occurrence". Else, or if you are in the business of selling from your tanks, check "1 million dollars per occurrence". For owners of 101 or more petroleum underground storage tanks, check the '2 million dollar annual aggregate" box. All others need only check the "1 million dollars annual aggregate' box. Please be aware that failure to provide the financial responsibility document to this office within 30 days will result in your Permit to Operate being revoked. (25285.1 (b) California Health & Safety Code). ' If you have any questions, or would like help in completing the Certification of Financial Responsibility, please contact Howard Wines, Hazardous Materials Technician, at 326-3979. Sincerely, Hazardous Materials Coordinator REH/dlm nd Hazardous Materials Storage Facility · : ....... ::::,::?:::'?"?' ;:-'., .:;:.~/;::' ..,.' ~.:.:. ?.;::.:-5:::::~ .......... . . C 0 ~T~ 0~:~}::}:~'':~:~' ~. ~ ~ :~::::'"' '<:~:::.:~. ~;;;~ ~:::¢::..;;::::~.:....~;':;~.':.~:*:.:~L' .:~' "~:~. '":::c-;';"......¥¢:..~;~:~__~ ~~ ~~ Number Substance C ~0 ~ ~!.{~%.:~:::::?:' In'~ i ~Ji~?:~:::.;., ~ }~. ~T ype M ohi{~}~id:~;~::?~?::. Type Method Monitoring .... :..:., ,::;~ ':., '.: ? Issued By: ;"' :?~} ::::::::::::::::::::: ...... ~;:>:.:..:?:.5::::.:5.::~::.:::~f<' :~:¢~::':5~:::::%"~D~ '~;?~;~ '~::. :.;:?;q ~ ~ .;~:::~ ...... ; · ...... ; .......... ....-'.:.;::...,.'...: ..::;f. ' ,;~..:::. s~,::,...,..¢........:...~::.,.:. ~: ~ .......... Issued o. ' HAZARDOUS MATERIALS DIVISION ~?ot t G~I(¢ }~ace C 1115 Chester Ave., 3rd Floor Bakersfield, CA 93301 ~cX O7 (805) 320-3979 "" .~. Ralph fi. Easy, Hazardous Materials Coordinator Valid Item: I [' {c~q'A' to: ~, [qq~ CiiJ,~R REC'.T/ON 'N 0 T,.~ E BAKERSFIELD FIRE DEPARTMENT :.,,,~o 0 ~ g ~, Sub Div.~70[ S ~)/~ ~~ ~t atYOUtheareaboveherebYlocation:required to ma~e following' corrections .' . ~ ' /" V ~tg°~~~~' ~2rre;tions~ I~/lf /q ~ t . MONROE Bakersf ie ld Fax :805-$96-1650 Mar 16 '95 23:45 P. 01/02 KERN ttI6H SCHOOL DISTRICT PAGES L~CLUDING COVER SHEET. 3701 EAST BELLE TERRACE, SUITE "C" (805) 631-3199 FAX (805) 398.7042 MONROE Bakersfield Fax:~05-S96-1650 Mar 16 '95 2S:45 P. 02/02 K~RN HIGH BCHOOL DISTRICT TRANSFORTATIOM D~PARTMENT RILSFONSE FLAIl FOR REMOVAL OF UNAUTHORI:~.ED R~LE~s~JE FROM SECONDARY CONTAINMENT Required by Suctions 2632(dj and 2641(h) CCR Upon recognition of e suspected unauthorL~ed releue from the primary containment to the interstitial spuco of either a double-contained tank or product line, or a suspected bz~aeh in the secondary containment, vehicle maintenance personnel will notify the Director of Trundpo~tion The D~ector or Transportation will urranfe for e qualified contractor to verify the suspected breach o£ primary or secondary containment ual/or verify proper operution of the monitorial system. Upon confirmation of loss or tank system integrity, the tank system will be taken out of service and product will be removed from primary container. If relessed hufardou substanee~ ~ueh the environment or create m fire hazard, contact the Bakersfield Fire Department Hazardous Materinla Division. (326-30791 The Dfrector of Transportation will authorize &L1 work necessary under this phn. Representatives of the tank manufacturer will conduct an inspection of the leakinf tank to determine repairability and coverufc under the manufacturers wurrsnty. All repdru to the failed tank will be completed pursK~nt to the requirements of :~3 ¢¢R, Section 2661, and by or under the direct super,boa of the tank manufacturer. Upon completion of repe~rs, the tank will be precision tested in order to ensur~ tlu~k integrity. Unauthorized releases to the Interstitial spree between prlmtr~ and second~t~ contahxment will be removed under the supervLsion of, ~ud in aceordanee with, the speclflettions ~nd tmnk design of the mannfmcturer. The e(lnipment required to ummpllth thLs auk will be specified mad obtained per the manufacturer recommendations. Contaminttinf lnnterlsls will be properly trm]Llported fLnd disposed of under manifest. Reactivate monitorinl~ system prior to b~f the UST system bac& into sel~ice. Quee~ions ref;srdinf this response plan should be directed to Bud Bank~ton, Director of Transportation ~ 631-3199. 01/09/95 12:02 9805 398 7042 BUD BANKSTON ~001/002 KERN HIGH ,SCHOOL DISTRICT 3701 E. BE! LE TERR,qCE BAKERSFIELD, CA. 93307 PHONE: (805) 631-3199 DATE:/- ?-~ ~ PAGES INC'LUDINO COVER .. K&X (805)398-7042 01/09/95 12:02 '~'805 398 7042 BUD BANKSTON ~002/002 ?cff Ooz KF. RN HIGH SCHOO DISTRICT ~.~,~ ~~ BOARD OF TRUSTEES ~ ~ ~ t~.~ Kenner_h E. Secor, President Fred L. Starrh, Vice President David C. Crenshaw. Clerk ~-- :~ ot~ -'7 Earle g. Gibbons Sandra V. Se. rrano ~ THOMAS N. JONES, Ed.D., SUPERINTENDENT 2000 T"VVENTY-FOURTH STREET o BAKERSFIELD * CALIFORNIA · g3301-389~ * (805)631-3100 * FAX; (805)631-2133 DR. NEAL W. Gl. SEN A&~l~le ~upedl~tal~elent PRODUCT TANK TEST DATE REMA2~S UNLEADED 1 10/14/94 2 MIN. ACTIVATION DIESEL 2 10/14/94 2 MIN. ACTIVATION WASTE OIL 3 10/14/94 2 MI~ ACTIVATION CORRECT ~ll~N NOTICE BAKERSFIELD FIRE DEPARTMENT :'?>-~-. su~ ~. ~7o~ ~_ ~)~ ~~ You are hereby required to make the following corrections at the above location: Cor. No ] / l uompieuon Date mr uorre~uons / / - - !nspecto~ T~J~ . .Bak'er~field Fire Dept. .,<,', d~x ~ Bakersfield, CA 93301 FAClLI~ NAME ~ 0,'~ I, ,~L~I ~%,>¢ ~,~. BUSINESS I.D. No. 215-000 FACILI~ADDRESS ~7~1 ~ ~)~ 7~>~ Cl~ ,~¢~lJ ZIP CODE FACILI~ PHONE No. ~ ~1 ' ~t ~ ~m ;~ INSPECTION DATE lO/It/~ ~ ~ .~ TIME IN ~' ~ TIME OUT /~, ~ ~ ~ ~ ~a~:~ ~5, ~ ~ ' In~ ~te In~ ~te Inst ~te INSPECTION ~PE: ~- 7- ~ 3 ~- 7 ~ ROUTINE /' FOLLOW-UP s~ z~ ~ s~e REQUIREMENTS ~ ~ ~a y~ ~ ~a yes no ~a la. F~s A & B Subm~ ~ ~ ~ 1 b. F~ C Su~ ~ ~ lc. O~mting F~ Pa~ ~ ~ ~ i~ Id. S~te Surcharge Paid ~ ~ ~ lc. S~te~nt of Fi~ial R~si~li~ Su~ ~ ~ ~ lf. W~en Contm~ E~sts ~n ~er & O~mt~ to O~mte MST ~ ~ 2a. ~lid O~mting Pe~ ~ ~ / ._ ~ 2b. Ap~ov~ Wr~en Ro~ine Mon~ng Pr~ure ~ / .... " ~ 2c. Una~ho~ Relea~ R~n~ Plan ~ ~ ~ ~ ~.~ ~ ~ ~. Tank Int~ T~I in ~st 12 Mohths ' ' ~ ~ 3b. Pr~ur~ Piping Int~ri~ Test in Last 12 Months [ ~ ~" ~. Suction Piping ~ghtn~ T~t in Last 3 Yearn ~ ~ ~. Gmv~ FI~ Piping ~ghtn~ T~ in Last 2 Y~m ~ ~ ~. T~ R~u~s Subm~ W~hin ~ Da~ ~ ~ 3f. DaiN ~sual Mon~oring of Su~i~ Pr~t Piping ~ ~'.~ ~ ~ ~. ~al In~ento~ R~ncil~ti~ Each ~n~ ' [ ....... ~ ~. Annual Invent~ R~nciliati~ Statement ~u~ [ ~ ~. Metem Calibmt~ Annual~ ~ ~ ~ 5. W~ Manual Tank Gauging R~ds f~ Small Tanks . ~ ~ 6. Month~ Statistical Invento~ R~ciliation R~u~s ~ ~ 7. Monthly A~tic Tank Gauging Resu~s ' ~ ~ 8. Ground Water ~n~ing ~ / 9. ~ MonRodng ~ ~ 10. Continuous Intemtitial Monitoring f~ Doubl~Wall~ Tan~ ~ ~ / 11. M~hani~l Line L~k Det~t~ ~- ~ ................ ~' 12. El~ronic Li~ Leak Det~tom ~ ~ ~ 13. C~tinuous Pi~ing Mon~odng tn ~um~ [ ~ ~' ~ ,f 15. Annual Maintenan~Calibmtion of L~k Det~ Equi~ -~ 16. Leak Det~tion Equipment and T~t Meth~s Ust~ in LG-113 ~ ~ ~ ~ 17. Wr~en R~rds Maintain~ ~ S~e ~-~ ~ ~ 18. Re~ Changes in U~g~CondEi~s to O~mti~~ ~. Pr~ur~ of MST S~tem WEhin ~ Da~ - '~ ' ' 19. Re~ Una~ho~ Relea~ W~hin 24 Houm ~ ~ ~. Approv~ MST S~tem Re.irs a~ U~md~ ~ ~ 21. R~ds Sh~ng Cath~ Prot~ti~ Ins~ ~ / ~. S~ur~ Mon~oHng Wells ~ ~ ~. Drop Tu~ ~~~~~~ ~~'~ ~ _ -,~ OFFICE TELEPHONE No. ~- ~ j " .... FD FILE CONTE.~]TS SUMMARY Ac~$ui'~y Date · Of Tanks Comments TANK .I · .~ (FILL OUT SEPARATE FORM FOR EACH TANK) FOR EACH.. SECTION, CHEC_K ~ APPROPRIATE BOXES 'H. l. Tank is: []Vaulted []Non-Vaulted [~]I]ouble-Wall ' ~Single-Wall 2. ~ Material Carbon Steel ~] Stainless Steel [] Polyvinyl Chloride 1'] Fiberglass-Clad Steel Fiberglass-Reinforced Plastic []-]Concrete []-1Al~in~ []Bronze []Unknown Other. (describe) Date Installed Thickness (Inches) Capacity (Gallons) Manufacturer 4. Tank Secondary Contai6ment - o []DOuble-Wall []Synthetic Liner DLined Vault ~None [-1Other (describe): Manufacturer: .' []Material ThiCkness (Inches) ' Capacity (Gals.)_ 5. Tank Interior Lining . "~ · ....... ..... i ............... ~Rubber --[-1A~kyd --['1EpoXy -['qehenolic . ~]Glass-~ l'qClay = []Unlined i~l~lLlnkno~ · ['1Other (describe): · 6. Tank Corrosion Protection '-]~G~lvanized ~ass-Clad [']Pol~thylene Wrap [-]Vinyl Wrapping rqTar or Asphalt l~Unknown []None []Other (describe): Cathodic Protection: ~None [-]Impressed Current System ['lSacri'ficial Anode .System Des~rib~ System & Equi~ent: '- 7. Leak Detection, Monitoring, and Interception ......... a. Tank: [-]Visual (vaulted tanks only) [~Groundwater .Monitoring' Wmll(s) DVadose Zone Monitoring ~ll(s) [~U-Tube Without Liner [~U-Tube with C~patible Liner Directing Flow to Monitoring We.il(s)'* Vapor Datector* [] Liquid Level Sensor* [] Conductivit~ Sensor= D Pressure sensor in Annular Space of Double Wall Tank ' [] Liquid Retrieval & Inspection Fr~m U-Tube, Monitorirg Nell or Annular Space [] Daily Gauging & Inventory Reconciliation [],Periodic Tightness Testim! b. Piping: Flow-Restricting Leak Detector(s) for'Pressurized Piping= D Monitoring S~mp with Race~y [~Sealed Concrete Race~y []Half-Cut Compatible Pipe Raceway DSynthetic Liner Race~ay [] ~,nown [] Other , · Describe Mak~ & M~del~ ' 8. Tank Tightness ~--Th~s Tank Been Tightness Tested? ~Yes ~No []Unknown Date of Last Tightness Test Results of Test Test Name Testing Company 9. Tank Re~air Tar~k RePaired? [~Yes ~No []Unknown Date(s) of Repair.(s) Describe Repairs 10. Overfill Protection ~[Operator Fill's~ Controls, & Visually Monitors Level []Tape Float Gauge [-]Float Vent Valves ~Auto Shut- Off Controls []Capacitance Sensor ~Sealed Fill Box ~None []Unknown ~Other: List Make & M~dei For Abo~e a. Underground Piping: ~Yes ~No ~Unknown Material ~-" .................................. -Th ! c kness ('! nc .hes) ................... D lame ter ................ Manu factur er ....................: .......... ~ ......... ~ ..... []Pressure []Suction" ~]Gravity Approximate Lengt~h Of Pipe ~ b. Underground Piping Corrosion Protection : [-]C, alvanized [-1Fiberglass-Clad [.']Imp~essed Current ~'lSacrtficial Anc~te [-]Polyethylene Wrap ~Electrical-Isolation ~]VinYl Wrap l-]Tar or A~alt ~Unknown l'qNone [~]Other (describe): c. Underground P~ptng, Secondary Contatrment: TANK ~' ~ (FILL OUT sEpARATE FORM FOR EACH TANK) 'FOR EACH SECTION, CHECK ALL APPROPRIATE BOXES H. 1. Tank is:. []Vaulted []Non-Vaulted []Double-Wall [~Single-Wall 2. ~ Material .- ~Carb0n Steel []-]Stainless Steel []Polyvinyl Chloride []Fiberglass-Clad Steel --. , ~ Fiberglass-Reinforced Plastic [] Concrete [] Alunin~ ['] Bronze []Unknowa FI Other (describe) - Bate Ins~---~ ~ickne~- ('i~CheS) ..... -CaPadi ty (GallOnS).' =='='<:='-= :' ..... Manufacturer-- ...... ~ ...... - .......... 4. ' Tank Secondary Co6tainment ' []Double-Wall Fi Synthetic Liner []Lined Vault ~None ~Unknown . ~]Ot. her (describe): 'Manufacturer: ['~Material . Thickness {Inches). Capacity (Gals.) 5. Tank Interior Lin'lng ' ...... ~Rubber .... []-Alkyd []Epoxy .... []Phenolic...-~Glass _ []Clay =[]~lined ..... ~ll~knom []Other (describe): 6. Tank Corrosion Protection --~rGalvani'zed ']~'f6~ass-Clad []Poi~thylene Wrap []Vinyl Wrappin~ :.. i~Tar or Asphalt []tlnkno~ F1Non. FlOther (describe): Cathodic Protection: ~None Fllmpressed Current $~r. em' FlSac'rifi'cfil hnod~ .System Describe System & Fxtutlanent: . ,. , 7. Leak Detection, Men&torito, and Interception a. Tank: FiVisual {vaulted tanks only) FlGroundwater Monitorirg' W~ll(~) [] Vadose Zone ~lonitorir~j W~ll (s} F1 ti-Tube Without Liner []~U-Tube with Cmpatible Liner Directing Flow to Monitoring Vapor Detector* []Liquid Level Sensor* Fi Conductivit~ Sensor' · [] pressure Sensor in Annular Space of Double Wall Tank Fl Liquid l~trteual & Inspection Frm U-Tube, Monitoring l~ll or Annular S~ace. ~lDaily Gauging & Inventory Reconciliation []Periodic Tightness Testim.! [] None F1 Unkno~ [] Other b. Piping: Flow-Restricting Leak Detector(s) for Pressurized Piptrg' [-]Monitoring S~p with Race~y [-]Sealed Concrete Race~y []Half-Cut C~mpatible Pipe Raceway Fi Synthetic Liner Racm~¥ [] Other · Describe ~a~e & 8. Tank Tic~htness ~--Tbis Tar~ Been Ti~ht~ess Teste~? [-~Yes ~o Date o~ Last Ti~htns~ Test Results o~ Test Test Name Testing Ccmpany . ~. Tank ~ Taruk Repaired? ~]¥es [~o []Unkno~ Date(s> o~ Rapair.(s) Describe Repairs 10. Overfill Protection ~Operator Fills, Controls, & Visually ~onitors Level []Tape Float Ga~e []Float Vent Valves ~Auto Sbu~- Off ~ontrols E3Gapacit~nce Sensor []Sealed Fill Sox Fi~one []Other: List Make & ~xlel ~o~ ~e Devices a. t~der~rou~ Pipir~: [~es Fi~o ~]tlnknown Mat~..rial ................................... Thickness "Tfnches) ~Diameter ..............Manufacturer ........................ = ~]Pressure Dsuction OGravity Approximate Lengt:h Of Pipe ~ b. Underground ptping Corrosion Protection : []Galvanized []Fiberglass-Clad l']Imlxes-qed Current []SaCrificial []Polyethylen~ Wrap FiElectrical .Isolation ff3¥inyl Wrap [:]Tar or ~Unknown [:]None []other (describe): c. und_erground ptpIng, Secomlary Contairment: TANK .t - ~ (FILL OUT SEPARATE FORM FOR EACH TANK) " FOR EACH SECTION, CHECK J~r.~. APPP, OPRIATE BOXES H.. 1. Tank is: r~vaulted [~Non-vaulted r'lDouble-Wall '~Singl~=Wall 2. Ta~ Material []Carbon Steel [] stainless Steel [] Polyvi~yl Chloride []Fiberglass-Clad Steel D Fiberglass-Reinforced Plastic [] Concrete [] Al~inu~ [] Bronze [']Unknown. [] Other (describe) .... ~ate lns~-----i-~ ~ickness (Inches) ~'~apa~t't-Y i~allon~') ............. :-handfacturef 4. Tank 'Secondary Contai~ent ' · [~Double-Wall . r~synthetic Liner ~Lined Vault ~None []Unknown []Other (describe): -Manufacturer: ~TMaterial Thickness (Inches)' Capacity (Gals.) []Other (describe): 6. Tank.Corr°sion Protection ' --~Galvan£zed ~~ss;¢lad "r'lPol~thylene ~ap r'lvin¥1 ~ping []Tar or Aspl~lt r']Un~ ['1None ['1Other (describe): Cathodic Protection: []None []Impressed Current System ~lsacrffl.cf~ Anode.. Systm. Describe System & ~quita~ent: ?. Leak Detection, Monitorincj, and Interception ' a. Tank: FlVisual (vaulted ~anks only) VIGroun~ter Nonito~in:j' ~ll(s) l~Vadose Zone ~onito~ing Well(s) l'1~ ~ithout Line~ U -Tube with ¢c~patible 'Liner Directing Flo~ ~o ~onitorirq Vapor Detector* [] Liquid Level Sensor~ E] Conductivit~ Sensor* [] Pressure Sensor in Annular Space of 'Double Wall Tank [] Liquid Betrieval & Inspection Fr~m U-Tube, Monitoring Well or Annular S~ace ~Daily Gauging & Inventory Reconciliation []Periodic Tightness Testim! []None []unknow~ [] Other b. Piping: Flow-Restricting Leak Detector(s) for Pressurized Piping' [] Monitoring Sump with Race~y [] Sealed Concrete Race~y r~Half-Cut Compatible Pipe Raceway []Synthetic Liner Raceway ~No~e [] Unknown ~ Other · Describe Make & ~k;del: ' 8. Tank Tightness ]~is Tank Been Tightness Tested?' []Yes []No ~qUnknown Date of Last Tightness Test Results of Test Test Name TeSting C~upany 9. Tank Re?air Tank Repaired? ~Yes ~No. []Unknown Date(s) of Repair.(s) Describe Repairs 10. Overfill Protection ~Operator Fills, Controls, & Visually Monitors Level ~Tape Float Gauge []Float Vent Valves []Auto Shut- Off. Controls []Capacitance Sensor ~Sealed Fill Box ~]None ~unKnown []Other: List Make & Model Fo~ Above Devices a. Underground Piping: ~Yes []NO []Unknown Material Thickness ~'(~'hch~s)-~'[~F' ...... Dfameter .....~j--~ ..... Manufacturer ~i ~Pressure. E]Suction F'lGravity ~---~imate LengtJ1 of Pipe R~ ~, . . b. Underground Piping Corrosion Protection : []Galvanized I-]Fiberglass-Clad ~Imp~essed Current []Sacrificial An~le [-]Polyethylene Wrap ~-]Electrical Isolation ~]Viny! Wrap []Tar or A~ialt []Unknown [-1None []Other (describe): F~.I~&e~ ~oJ~T c. Underground Piping, Secondary Contair~ent: · ' TANK ~' ~ (FILL OUT SEPARATE FORM FOR ~ACH TANK) FOR EACH SECTION, CHECK ;~r-t APPP, OPRIATE BOXES .' 'H. 1. Tank is: [-]Vaulted []Non-Vaulted 'I-]Double-Wall ~Single-Wall 2. ~ Material D Carbon Steel [] Stainless Steel n]Polyuinyl Chloride ~Fiberglass-Clad Steel ~ Fiberglass-Reinforced ·Plastic []Concrete [] Altm~in~ [] Bronze []Unk~owa [] Other (describe) Date Ins~-----~ ~ickness (Inches) Capacity (Gallons) '~anufacf~rer ..... . . .. · , · F.o · 4. Tank Sedondary Containment I-]Double-Wall [']Synthetic Liner []Lined Vault ~None []Unkno~ . ... ~]Other (describe): Manufacturer: · F~Material Thickness (Inches) Capacity (Gals.) 5. Tank Interior Lining . ....... " []Other (describe): 6. Tank Corrosion Protection " --~Salvanized -~~-'~aSs~Clad ~Polyethylene Wrap []Vinyl Wrapp~n~ [-]Tar or Asphalt []Unknown []None []Other (describe): ~ · Cathodic Protection: []None F]Impressed Current System ~Sacrificiai Anode Syst~ Describ~ System & EguiImment: 7. Leak Detection, Monitoring, and Interception a. Tank: []Visual (vaulted tanks only) C]Groundwater Monitorirg' Wmll(s) ~Vadose Zone Monitoring ~ell(s) [~U-Tube Without Liner F]U-Tube with C~upatible Liner Directing' Flow to Monitoring ~ Vapor Detector* [] Liquid Level Sensor* [] Conductivit~ Sensor' n Pressure Sensor in Annular Space of Double Wall Tank [] Liquid B~trieval & Inspection Fr~ U-TuDe, Monitoring Well or Annular S~ace ~Daily Gauging & Inventory Reconciliation []Periodic Tightness Test'i~.! ' i~ None [] Unknown [] 0~er b. Piping: Flow-Restricting Leak Detector(s) for Pressurized Piping' [2]Monitoring S~,~p with Race,my C]Sealed Concrete ~ace~y ~Half-Cut Ccmpat:ible Pipe Raceway []Synthetic Liner Race~y ]~None [2] Unknown [] Other · Describe Ma~e m ~deI% · 8. Tank Tiqhtness l~'~-This Tar~ Been Tightness Tested? Oyes 5~NO ~unknown Date of Last Tightness Test: Results of Test: Test Name Testing. C~npany 9. ?an__~k Re.pair Tank Repaired? [2]¥es ~lNo []unknown Date(s) of Repair.(s) Describe Repairs 10. Overfill' Pro~ection ~Operator Fills, Controls, & Visually Monitors Level nTape. Float Gauge []Float Vent Valves [] AuCo Shut- Off COntrols [2]Capacitance Sensor []Sealed Fill Box []None Ulunknown ~Other: List Make & Model For Above Devices ll. Piping a. Underground Pipim~: ~Yes ~No [-]Unknown Mater ial ................................ -Thickness-' (inc hes)~"'~:-[~F'--" D i'~ ~r'- ~-', ........ Manufa'ct~rer- ..... i~ ~Pressure ~Suction []Gravity Approximate Lengtdu of Pipe Rm~ ~$' b. Underground Piping Corrosion Protection : [-]Galvanized []Fiberglass-Clad . ~Xmlxessed Current [2]Sacrificial An~e Polyethylene Wrap F]Electrical Isolation []Vinyl Wrap []Tar. or'A~.lt _ Unknown. [2]None ~[Other (describe): ~.&~, ¢,~r ~f c. Undergrota~d Piping, Secondary Contai~uent: Division or Environmental Hear Application 1700' Flower Street, Bakersfield, CA 93305 . .. APPLICATION FOR PERMIT TO OPERATE UNDERGROUND HAZARDOUS SUBSTANCES STORAGE ['ACILITY Type of Application (check): ~New Facility ~]Modification of Facility ~Existing Facility ~Transfer of Ownership A. Emergency 24-Hour Contact (name, area code, phone): Days ~.A'. Type of Business (check): ~]~asoline St~ti~h ~Other (d~s~ribe) Is Tank(s) Located on an Agricultural Farm? ~Yes Is Tank(s) Used' Primarily for Agricultural Purposes? ~Yes [] No Facility Address I~a~ ~ $~,. Nearest Cross T ., R SEC (Rural Locations (~ly) Operator ...................................................... ' ........ Contact"person Address Zip Telephone B. Nater to Facility .Provided by ~-~& ~,.~ t~,.,&a~ Depth to' ground~mta~r ~-.' ~il~ (~aracteristics at Facility $'~4v Basis for Soil Type and 'Groundwater Depth' Determinations ~;.t. ;,;~ C. Contractor CA Contractor' s License No. Add r ess Zip Te lephon~ Proposed Startin~ Date Proposed Ccmpletion D~te Worker's C~pensation CertifiCati6r~ ! Insurer D. If This Permit Is For Modification Of An Existing Facility, Briefly Describe Modifications Proposed E. Tank(s) Store (check all that apply): Tank i~ ~ast~ Product Motor Vehicle Unleaded Regular Premi,~ Diesel ~aste F. Chemical C~mposition of Materials Stored (not ~ecessary for motor vehicle fuels) ' Tank ~ Chemical Stored Inon-co~mercial name) CAS ~ fir known) Chemical Previously Stored (if' different) G. Transfer of Ownership . . Date of Transfer Previous Owner Previous Facility Name I, accept full9 all obl'igations of Permit No. issued tc · I understand that the Permitting Authority may review and ......... .~odif~ or -terminate the transfer of the Permit to ~Op~rate this ~ndergro~d storage~ This fora has been C~mpleted under penalty of perjury and to the best of my knowledge is true and correct. STAFF MEMBERS INVOLVED WITH THE FUELING OF VEHICLES AND 'EQU PMENT SHALL RECEIVE TRAINING BY THE DRIVER INSTRUCTOR IN THE PROPER OPERATION OF FUELING EQUIPMENT. 1, DRIVERS SHALL NOT LEAVE THE FUELING STATION WHILE DISPENSING FUEL. 2. IF WHILE FUELING A SPILL OCCURS, NOTIFY THE VEHICLE MAINTENANCE SUPERV I SOR I MMED I ATELY, 3. MONITORING EQUIPMENT WILL BE OPERATED BY AUTHORIZED PERSONNEL ONLY. 4. SELECTED STAFF MEMBERS SHALL REVIEW THE GILBARCO OPERATING INSTRUCTIONS AND VERIFY PROPER OPERATION OF EQUIPMENT ON A DAILY BAS I S. THE METHOD FOR MONITORING WILL BE THE USE OF A GILBARCO TANK MONITOR 3. SEE ENCLOSURE 1. THE TANK AND MONITOR LOCATION: 3 701 E i BELLE TERRACE Gu I TE C BAKERSFIELD, CA 93307 SEE ENCLOSURE 2. RESPONSIBLE' STAFF: BEN SEYKORA 631-3200 (HOME) 821-0708 BUD BANKSTON 631-3203 (HOME) 393-0308 ELECTRONIC MONITORING AND SPILL RESPONSE PLAN 1. PROCEDURE FOR DISTINGUISHING BETWEEN "FALSE ALARM" AND "UNAUTHORIZED OR LEAK" A. LEAKi SENSOR DETECTION ALARM SOUNDS 1) VERIFY BY ALARM RATE AND VISUAL LED. A~) FUEL LEAK B) SENSOR OUT C) WATER LEAK B. THE; RATE AT WHICH THE LEDs FLASH AND THE AUDIBLE BEEPS VARIES ACCORDING TO THE TYPE OF ALARM. A FUEL LEAK INDICATION WILL CAUSE THE MOST RAPID FLASH AND BEEP - SLOWER WILL BE SENSOR OUT IND CATION AND SLOWEST WILL BE A WATER INDICATION. 1) THE CONTROL PANEL CONSISTS OF ELEVEN ALARM CAUSE LED INDICATORS THAT WILL FLASH WHEN AN ALARM CONDITION IS , DETECTED. THREE OF THESE LEDs - FUEL LEAK, WATER LEAK AND ~'~ ~% HAS DETECTED THE CONDITION. IN ADDITION, AN AUDIBLE ALARM WILL BEEP WHEN ANY SENSOR ALARM CONDITION IS DETECTED. k THE ALARM RESET IS USED TO RESET THE ALARM RELAYS AFTER AN ALARM INDICATION. HOWEVER, WHEN AN ALARM CONDITION IS ELIMINATED (I E EXCESSIVE WATER REMOVED) THE ALARM WILL ~ ~ ~ RESET ITSELF AUTOMATICALLY THE ALARM RESET WILL NOT RESET ~~ THE ALARM CAUSE LEDs, THESE LEDs WILL SHUT OFF PNLY AFTER THE CAUSE HAS BEEN CORRECTED AND THE SENSOR DETECTS NO OTHER ALARM CONDITION. - PAGE 2 - 2. PROCEDURE TO BE FOLLOWED IN THE EVENT OF AN ALARM SIGNIFYING UNAUTHORIZED RELEASE. A. WATER 1) NOTIFY SITE ADMINISTRATOR OR SUPERVISOR 2) PHONE BAKERSFIELD SERVICE STATION REPAIR 1230 SOUTH UNION AVENUE PHONE NO. 327-4659 B. FUEL 1) NOTIFY SITE ADMINISTRATOR OR SUPERVISOR 2) VERIFY LEAK ,,3) PHONE KERN ENVIORNMENTAL SERVICE TO REMOVE PRODUCT FROM TANK IF NECESSARY -- PHONE NO. 589-5220 4) NOTIFY KERN CO, ENVIORNMENTAL HEALTH SERVICE DEPT. PHONE NO. 861-3636 DIRECT CORRECTION OF LEAK AND CLEAN UP System Start-Up and Operating Instructions Tank Monitor 3 Four-Tank System SECTION 3 --. SYSTEM OVERVIEW (ENCLOSURE NO. 1) A. Inventory Monitoring Capablities ., Tank Monitor 3 has an electronic continuous monitoring capability designed to tighten inventory control of fuel stored in underground tanks. It measures fuel height, fuel temperature and water height. The system also provides fuel volume, time and date. IMPORTANT: THE TANK MONITOR 3 WILL FUNCTION ACCURATELY WITH ONLY CERTAIN APPROVED FLUIDS. SEE SECTION 4.M. OF THIS MANUAL FOR THE LIST OF APPROVED FLUIDS. This information, acquired automatically, can be used to speed shift changes by eliminating tank sticking and manual report filing; to reduce inventory errors and spot losses caused by theft, leaks or meter misca!ibration; and as a basis for sound inventory practice. Tank Monitor 3 features reports and programmable limits that add extra security to your operation. These include automatic reports that confirm bulk deliveries, a programmable high level limit to warn of overfills during bulk deliveries, programmable Iow-fuel and high- water limits and a theft limit to warn of rapid changes in inventory levels caused by theft or a major tank failure when the shutdown mode is being used. 'All programmable limits can activate one or both alarm relays built into the Tank Monitor 3 monitor. :' System Start-Up and Operating Inst.ruc-!~im~!s. Tank Monitor 3 Four-Tank Systt:m' y~ B. Leak Detection Capabilities The Tank Monitor 3 monitors the annular space and piping sumps in i' double-wall tanks for the presence of hydrocarbons or water. Up to eight sensors can be connected to a single console. Each sensor can detect the presence of water or fuel at any point ' " along its length, and when either is sensed, an audible alarm and .. flashing alarm-cause LED indicators are triggered. The flashing LEDs indicate the type of leak -- fuel or water -- and identify which sensor .. .. in the system has detected the condition. The leak sensor can detect as little as 1 / 16" of £uel, even if the l'ue~ is .. floating on water. The sensor can distinguish between fuel and water and, if both are present, .the fuel leak indicator --representing the more serious condition -- will be illuminated. Note: A single sensor can detect both water and fuel. However, when fuel is detected, the sensor will indicate first a water Icak and then, . within a period~oftime (depending on the type of fuel), activate the fuel leak indicators. It is recommended that you enter a Water Alarm Delay Time (Function Codes --A and --B) to give the sensor time to evaluate the condition and activate only Ihe fuel h~ak alarm. If only ,water is Present, the water leak indicators will activate at the end of the delay period. The recommended delay periods vary according to the type of fuel. See Section 4.T. in this manual for setup information on Water Alarm Delay Times. ( Tank Monitor 3 leak sensors can also be installed in piping sumps to monitor the area for fuel or water. " In addition, the front-panel LEDs and audible alarm will indicate, if a sensor fails or is disconnected, a "Sensor Out" condition and identify 'the sensor. IMPORTANT: DO NOT EXCAVATE TANKS OR TAKE ANY OTHER REMEDIAL ACTION BASED SOLELY ON TANK MONITOR 3 INVENTORY REPORTS OR LEAK ALARM INDICATIONS. THE TANK MONITOR. 3 IS NOTA PRECISION LEAK TEST DEVICE. CALL · FOR A "PRECISION" TEST TO CONFIRM A SUSPECTED LEAK! (ENCLOSURE NO. 2) HH~NT£~a I.,~ ......... ..,~ · ~ :.~...:2 ~1~-:, ~ i i ~11 it!.~ll,~liilll,.. · 't [ ................... ........................... " '" . e ~'~._~ :. ~ · ~... _~.. . . ' ~/ '' ~: -, ~ ...... [: .-.?-,.~'.--~=-:-.--:- .... _~ ,. , .~ ...... , . '". , ..... .~:?- f-~l~-:-C~ ~ ~ -., . .~ -- "~'"'" '~ :: "" ...... ~ I · "~: ....... " ~...: ..... u:.. ....... ' ..... ..... I ~ ............... .] · ._ .............. D~T_BiCT SUPPORT FACILITY' ~' KE~N HIGH SCHOOL DISTRICT ~ SITE PLAN BAKERSFIELD, CA GARY J. WICKS 2700 M Street, Suite 300 AGency Director Bakersfield, CA 93301 (805} 861-3502. . Telephone (805) 861-3636 Telecopier (8Q5} 861-3429 STEVE Mc CALLEY RESOURCE NT AGENCY DE?ARTNIE! Apri~ 4, 1990 'Kern High~c~o0I District ............................................................ - ............................... - . ...... 2000 24th Street Bakersfield, California CLOSURE OF 4 UNDERGROUND HAZARDOUS SUBSTANCE STORAGE TANKS LOCATED AT 1600 "B" STREET IN BAKERSFIELD, CALIFORNIA. PERMIT # Al146-16/160010 This is to advise you that this Department has reviewed the prolect results for the preliminary assessment associated with the closure of the tanks noted above. Based upon the sample results submitted, this Department is satisfied that the assessment is complete. Based on current requirements and policies, no further action is indicated at this time. It is important to note that this letter does not relieve you of further responsibilities mandated under the California Health and Safety Code and California Water Code if additional or previously unidentified contamination at the subject site causes or threatens to cause pollution or nuisance or is found to pose a significant threat to public health. Changes in the present or proposgd land use may require further assessment and mitigation of potential public health impacts. Thank you for your cooperation in this matter. IGG OUS MATERIALS SPECIALIST cc: McNabb Construction 7808"Oicott Avenue Bakersfield, CA 93308 ENVIRONMENTAL LABORATORIES, INC. PETROLEUM J' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., B~KERSFIEID, CALIFORNIA 93308 PHONE 327-4911 Petroleum Hydrocarbons (SOIL) 7808 Olaott Ave. E~e,poz""t..,: 20-Maz'-go Bakersfield, CA 93308 Attention: Ken Olinger La~'No : 1610-~ ~-- ~. , = ~. Date Sample Date Sample Date Sample Date Analysis Collected: · Received ~ Lab: Extracted: Completed: 23-Feb~gO 23-Feb-gO 02-Mar-gO 05-Mar'gO Re~orting Analysis Re~oz~cing Const/tuent Unlts Results Level ~zene ug/g . none detected 0.02 Toluene ug/g none detected O. 02 Ethyl ~enzene ug/g none detected 0.02 p-Xylene ug/g none detected O. 02 m-Xylene ug/g none detected 0.02 o-Xylene ug/g none detected O. 02 Total Pet.. Hydrocarbons ug/g p~nne detected 5 (Diesel) TEST METHOD: TPH by D.O.H.S. / L.U.F.T Manual Method. Individual constituents by Modified EPA Method 5020/8020. As Received Basis Comments: California D.O.H.S. Cert. ~102 ............................... ~. ~.. ~ ...................................... a~.x ..... L~._._ / ...... _ ! ENVIRONMENTAL LABORATORIES. IN(]. PETROIEII~ J' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Petroleum Hydrocarbons (SOIL) 7808 Olcott Ave. Report: 20-Mar-90 Bakersfield, CA 93308 Attention: Ken Olinger La~ No.: 1610-2 Sample Desc: Bus Barn by B.H.$. California Ave and Campus Way Diesel Tank North End 6' Date Sample Date Sample Date Sample' Date Analysis Collected: Received @ Lab: Extracted: Completed: 23-Feb-90 23-Feb-90 02-Mar-90 05-Mar-90 Reporting AnalYsis Reporting Constituent Units Results Level Benzene ug/g none detected O. 02 Toluene ug/g none detected O. 02 Ethyl Benzene ug/g none detected O. 02 p-Xylene ug/g none detected O. 02 m-Xylene ug/g none detected O. 02 o-Xylene ug/g none detected O. 02 Total Pet. Hydrocarbons ug/g none detected 5 (Diesel) TEST METHOD: TPH by D.O.N.S. / L.U.F.T Manual Method. Individual constituents by Modified 'EPA Method 5020/8020. As Received Basis Comments: California D.O.H.S. Cert. $102 ! ..... AnalYst ENVIRONMENTAL LABORATORIES, INC. PETROLEUM J' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Petroleum Hydrocarbons (SOIL) 7808 Olcott Ave. R~port: 20-Mar-g0 Bakersfield, CA 93308 Attention: Ken Olinger Lab No.: 1610-3 Sample Desc: Bus Barn bM B.H.S. California Ave and Campus Way Diesel Tank South End 2' Date Sample Date Sample :Date Sample Date AualysLs 23-Feb-90 23-Feb-90 02-1~Ia~-90 05-1%~-90 Constituent Units Results Level Benzene ug/g none detected 0 '. 02 Toluene ug/g none detected 0.02 Ethyl Benzene ug/g none detected 0.02 p-Xylene ug/g none detected 0.02 m-Xylene ug/g none detected 0.02 o-Xylene ug/g none detected 0.02 Total Pet. Hydrocarbons ug/g none detected 5 (Diesel) TEST METHOD: TPH by D.O.H.S. / L.U.F.T Manual Method. Individual constituents by Modified EPA Method 5020/8020, As Received Basis Comments: California D.O.H, $, Cert, ~102 ENVIRONMENTAL LABORATORIES, INO. PETROLEUM J' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Petroleum Hydrocarbons (SOIL) McNabb Constructi°n ..... ~.~-~ ....................... ~ ~ ~ .......... Da~e of Bakersfield, CA 93308 Attention: Ken Olin~r Lab No.: 1610-4 Samgle Desc: ~us Barn by B.H. $. California Ave and Ca~us Wa~ Diesel Tank ~outh End 6' Date Sample Date Sample Date Sample Date Analysis Collected: ReceiVed @ Lab: Extracted: CompleX: 23-Feb-90 23-Feb-90 02-Ma~-90 05-Ma~-90 Re~orti~ Analysis Constituent Units Results Level ~enzene u~/; none detected O. 02 Toluene u~/; none de~ O. 02 E%hyl Benzene u;/; none detected 0.02 p-XTlene u~/; none de~ '0.02 m-Xylene u~/; none detected O. 02 o-X~lene u~/; none det~=d 0.02 Total Pet. Hwdzocarbons u~/; none detected 5 (Diesel) TEST METHOD: TPH by D.O.H.S. / L.U.F.T Manual Method. Individual constituents by Modified KPA Method 5020/8020. As Received Basis Comments: California D.O.H.S. Cert. ff102 ENVIRONMENTAL LABORATORIES, INC. PETROLEUM J' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Petroleum Hydrocarbons (~O~b) 7808 01~%% Ave. Re~: 20'~90 ~field, CA 93308 A%~n%ion: ~n Older ~b ~.: 1610-13 ~le ~sc: ~ ~ ~ B.H.S. ~ife~ Ave ~ ~ W~ .D~e Sample Date Sample Date Sample Date Analysis Collected: Received @ Lab: Extracted: Completed: 2S-Feb-90 2S-Feb--90 02-["lar-90 05-Mar-90 Reporting Analysis Reporting Constituent Units Results Level Benzene ug/g none detected O. 02 Toluene u~/g none detected 0.02 Ethyl Benzene ug/g none detected 0.02 p-Xylene ug/g none detected 0.02 m-Xylene u~/g none detected 0.02 o-Xylene u~/E none detected 0.0~. Total Pet. Hydrocarbons ug/g none detected 100 (Diesel) TEST METHOD: TPH by D.O.H.S. / L.U.F.T Manuel Method. Individual constituents by Modified EPA Method 5020/8020. As Received Basis Comments: ' California D.O.H.S. Cert..102 ENVIRONHENTAI. PETROLE~JM ~ J' EGUN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 3274911 Petroleum Hydrocarbons (SOIL) ~cHabb Cons~c~ion Da~e of 7808 Olcott Ave. Re~o~: 20-~a~-90 ~e~sfield, CA 93308 Attention: ~en O1/~ger ~ab Ho.: 1610-14 Date Sample Date Sample Date Sample Date A~lysis Collected: Received @ Lab: Extraoted: Completed: 23-Feb-90 2~-Feb-90 02-Mar-90 05-Mar-90 Reporting Analysis Reporting Constituent Units Results Level ~enzene ug/g none detected 0.02 Toluene. ug/g none de~%~d 0.02 Ethyl Benzene ug/g none detected 0.02 p-Xylene ug/g none detected 0.02 m-Xylene ~/g none detected 0.02 o-Xylene ~g/g none detected 0.02 Total Pet. Hydrocarbons ug/g 11 5 (Diesel) TEST METHOD: TPH by D.O.H.S. / L.U.F.T Man~al Method. Individual constituents by Modified EPA Method 5020/8020. As Received ~asis Co~ents: Califoraia D.O.H.S. 'Cert. $102 ENVIRON~IENTAL LABORATORIES. INC. ~OETROLEUM J' d' EGUN, REG. CHEM. ENGR. 4100 PIERCE RD., B~KERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Purgeable Aromatics (SOIL) .... - .' *~ -_i£'~' ..___LLL*i'~_ ',. _7'._'~-~L~~ .... . ~:: .... .: - · ......... _ ...... ...~.. - 7808 Olcott Ave. Report: 03-Mar-90 Bakersfield, CA 93308. Attention: Ken Olinger La5 No.: 1810-5 Sample Desc: Bus Barn by B.H.S. California Ave. & Campus Way Date Sample Date Sample Date Analysis Collected: Received e Lab~' Completed: 23-Feb-90 23-Feb-90 28-Feb-90 Reporting Analysis Reporting Constituent Units Results Level Benzene ug/g none detected O. 02 Toluene ug/g none detected O. 02 Ethyl Benzene ug/g none detected 0.02 p-Xylene ug/g none detected O. 02 m~. Xylene ' ug/g none detected O. 02 o-Xylene ug/g none detected O. 02 Total Petroleum Hydrocarbons ug/g none detected 0.6 (Gasoline) .~ TEST METHOD: TPH by.D.O.H.S. / L.U.F.T. method. · Individ,~e! constituents by Modified EPA method 5020/8020. As Received Basis Comments: California D.O.H.S. Cert. ~102 ~NVIFIONYENT'AI. LABORATORIES, INC. [:~ETROI. E[IJf J' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Purgeable Aromatics (SOIL) 7808 Olcott Ave. Report: 03-Mar-90 Bakersfield, CA 93308 Attention: K~n Olinger Lab No.: 1610-6 Sample Desc: ~us Barn by B.H.S. California Ave. & Campus Way North Gas Tank ~t End 6' Date Sample Date Sample Date Analysis Collected: Received @ Lab:. Completed: 23-Feb-90 23-Feb-90 28-Feb-90 Reporting Analysis Reporting Constituent Units Results Level Benzene ug/g none detected O. 02 Toluene ug/g none detected O. 02 Ethyl Benzene ug/g none detected 0.02 p-Xylene ug/g none detected O. 02 m-Xylene ug/g none detected 0.02 o-Xylene ug/g none detected O. 02 Total Petroleum Hydrocarbons ug/g none detected 0.6 (Gasoline) TEST METHOD: TPH by D.O,H.S. / L.U.F,T. method, Individual constituents by Modified EPA method 5020/8020, As Received Basis Comments: California D.O.H.S, Cert, $102 ENVIRON~fENTAL LABORATORIES, INC. PETROLEUM J' J' EGLIN, REG, CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Purgeable Aromatics (SOIL) · ~CNabb Cons~ion ....... Date -Of 7808 01co~% Ave. Report: Bakersfield, CA 93308 Attention: Ken Olinger Lat~ No.: 1610-"/' Sample.Desc: Bus Barn by B.H.S. California Ave. & C~ .-~us Way .... : .... ~ ~. ......... ....... North Gas~ Tank West End_2: ................................................... . ........ · Da'ce Sample Date Sample Date Analysis Collected: Received @ Lab: Completed: 2S-Feb-90 2S-Feb-B0 2S-Feb-90 Reporting Analysis ReDort~ Constituent Units Results Level Benzene ug/g none detected O. 02 Toluene ug/g none detected O. 02 Ethyl Benzene ug/g none detected 0.02 p-Xylene ug/g none detected 0.02 m-Xylene ug/g none detected 0.02 o-Xylene ug/g none detected O. 02 Total Petroleum Hydrocarbons ug/g none detected 0.6 (Gasoline) TEST METHOD: TPH by D.O.H.S. / L.U.F.T. method. Individual constituents by Modified EPA method 5020/8020. As Received Basis Comments: California D.O.H.S. Cert. $102 ENVIRONMENTAL LABO RATO RI ES, INC. PETROLEUJl J' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Purgeable Aromatics (soIL) ~Nabb ~t~ion 7808 Ol~tt~Ave.' Re~: 0S-~90 ~field, ~ 9SS08 At~tion: ~n Older ... ~b ~.: 1610-8 ~le ~sc: ~ ~ ~ B.H.S. ~ifo~ Ave. & ~ W~ Date Sample Date Sample Date Analysis Collected: R~ceived @ Lab: Completed: 23-Feb-90 23-Feb-90 28-Feb-90 Reporting Analysis Reporting Constituent Units Results Level Benzene ug/g none detected 0.02 Toluene ug/g .none detected 0.02 Ethyl Benzene ug/g none detected 0.02 p-Xylene ug/g none detected 0.02 . m-Xylene ug/g none detected 0.02 o-Xylene ug/g none detected 0.02 Total Petroleum Hydrocarbons ug/g none detected 0.6 (Gasoline) TEST METHOD: TPH by D.O.E.S. / L.U.F.T. method. Individual constituents by Modified EPA method 5020/8020. As Received Basis Comments: California D.O.H.S. Cert. $102 c"~IVIFIO#MEtIT,~L LABORATORIES, INC. P~O~M J' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., ~KERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Purgeable Aromatics (~I~.) McNabb ~t~i~ ~ of 7808 Ol~tt Ave. ~: 03-~90 ~field, CA 93308 At~ntion: Ken Older ~6 ~..: 1610-9 ~le ~sc: ~ ~ ~ B.H.S. ~ifo~ Ave. & ~ W~ Date Sample Date Sample Date Analysis Collected: Received @ Lab: Completed: 23-Feb-90 23-Feb-90 28-Feb-90 Constituent Units Results Level Benzene ug/g none detected O. 02 Toluene ug/g none detected O. 02 Ethyl Benzene ug/g none detected 0.02 p-Xylene ug/g none detected O. 02 m-Xylene ug/g none dei~ued O. 02 o-Xylene ug/g none detected O. 02 Total Petroleum Hydrocarbons ug/g none detected O. 6 (Gasoline) TEST METHOD: TPH by D.O.H.S. / L,U.F.T, method, Individual constituents by Modified EPA method 5020/8020. As Received Basis Con~nents: California D.O.H.S. Cert. ~102 ENVIRONMENTAL LABORATORIES, IN(]. PETRO[.EUM J' J' EGUN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Purgeable Aromatics (SOIL) ~Nabb ~t~ion ~ of 7808 Ol~tt Ave. Re~: ~field, CA 93308 At~on: ~n Ol~r 23-Fe~90 ' 23-Fe~90 28-Fe~ ~ene ~g n~e de~ 0.02 Tolu~e '~g none ~~ 0.02 E~i ~ene ~/g none de~ 0.02 ~l~e ~g ~ne de~ 0.02 ~lene ~g none de~ 0.02 o-~l~e ~/g none de~ 0.02 To~ Pet~le~ ~~~ ~g none de~ 0.6 (~ol~e) TEST METHOD: TPH by D.O.H.S. / L.U.F.T. method. Individual constituents by Modified EPA method 5020/8020. As Received Basis Coments: California D.O.H.S. Cert. ~102 ENVIRONMENTAL LABORATORIES. INO. PETROLEU¥ J' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Purgeable Aromatics (soil) ~bb ~~i~ ~ of 7808 Ol~tt Ave. ~: 0~-~90 ~field, CA 93308 At~on: ~ Older ~b ~.: 1610-11 ~le ~: ~ ~ ~ B.H.S. ~ifo~ Ave. & Date Ssmple Date Sample · Date Analysis Collected: Received @ Lab: Completed: 2S-Feb-90 23-Feb-90 28-Feb-90 Reporting Analysis Reporting · Constituent Units ' Results Level Benzene ug/g none detected O. 02 Toluene ug/g none detected O. 02 Ethyl Benzene ug/g none detected O. 02 p-Xylene ug/g none detected O. 02 m-Xylene ug/g none detected O. 02 o-Xylene ug/g none detected O. 02 Total Petroleum Hydrocarbons ug/g none detected 0.6 (Gasoline) TEST METHOD: TPH by D.O.H.S. / L..U.F.T. meth°d. Individual constituents by Modified EPA method 5020/8020. As Received Basis California D.O.H.S. Cert. $102 LABORATORIES, INC. PETFIOLEU;,I d' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Purgeable Aromatics (SOIL) McNabb Construction ' Date--of 7808 Olcott Ave. Report: 03-Mar-90 Bakersfield, CA 93308 Attention: Ken Olinger No.: 1610-12 Sample Desc: Bus Barn'b~ B.H.$. California Ave. & Campus Way · - Sou*~.. C*,as Tank South, End 6'~ ........ Date Sample Date Sample Date AnAlysis Collected: Received @ Lab: CompleX: 23-Feb-90 23-Feb-90 28-Feb-90 Reporting A~lysis Reporting Oon~tituent. Units Results Level Benzene ug/g none detected O. 02 Toluene ug/g none detected 0.02 Eth~l Benzene ug/g none detected O. 02 p-X~lene ug/g none detected 0.02 m-X~lene ug/g none detected O. 02 o-X~lene ug/g none detected O. 02 Total Petroleum Hydrocarbons ug/g none detected O. 8 (Gasoline) TEST METHOD: TPH by D.O.H.S. / L.U.F.T. method. Individual constituents by Modified EPA method 5020/8020. As Received Basis California D.O.H.S. Cert. $102 ENVIRONMENTAL LABORATORIES, INO. PETROLEUM J' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-4911 Pargeable Aromatics (SOIL) 7808 Ol~tt Ave. ~: 03-~90 ~field, C& 93308 At~tion: ~n Older 23-Fe~90 23-Fe~90 28-Fe~90 ~nzene ~g none de~ 0.02 Tolu~e ' ~g none de~ 0.02 Et~l ~ene ~g ~ne de~ 0.02 ~lene ~/g no~ de~ 0.02 ~l~e ~g n~e de~ 0.02 o-~l~e ~g none de~ 0.02 To~ Pet~le~ (G~ol~e) TEST METHOD: TPH by D.O.H.S. / L.U.F.T. method. Individual constituents by Modified EPA method 5020/8020. As Received Basis Comments: California D.O.H.S. Cert. ~102 . ENVIRONMENTAL LABORATORIES. INC. PETROLEUM J' J' EGUN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-49!1 P~rgeable Aromatics (SOIL) 7808 01~ A~e. ~: 03-~90 ~field, CA 93308 At~ntion: ~n Older Date Sample Date Sample Date Az~.l~sis Collected: Received @ Lab: Completed: 23-Feb-90 23-Feb-90 28-Feb-90 Reporting Analysis Reporting Constit~t Units Results Level Benzene Ug/g none detected 0.02 Toluene ug/g none detected 0.02 Ethyl Benzene ug/g none detected 0.02~ p-Xylene ug/g none detected 0.02 m-Xylene ug/g none. detected 0.02 o-Xylene ug/g nOne detected 0.02 Total Petroleum Hydrocarbons ug/g none detected 0.6 (Gasoline) TEST METHOD: TPH by D.O.H.S. / L.U.F.T. method. Individual constituents by Modified EPA method 5020/8020. As Received Basis Comments: California D.O.H.S. Cert. $102 · ENVIRONMENTAL LABORATORIES. INO. [~ETROLEIJM J' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327"S911 Purgeable Aromatics (SOIS) - McHabb Construction Date of 7808 Oleott Ave. ' Report: 03-Mar--g0 Bakersfield, CA 93308 Attention ~ Ken Olinger La~ No.: 1810-17 Sa~mple Desc: Bus Barn b~ B.N.S. California Ave. & Campus Way ............................ -~'=~ -- ...... Middle'--Dispenser 2 '-~ ~.. ~- ........ - -. ............... - ....... - .......... '~' .....~ ......... ~' ...... ~"~ .................... '- Date Smm~le .Date Sample Date Analysis Collected: ,Received @ Lab: CompleX: ' 2S-Feb-90 2S-Feb-90 28-Feb-90 Reporting Analysis Reporting Constituent Units Results Level Benzene ug/g none detected 0.02 Toluene ug/g none detected 0.02 Ethyl Benzene ug/g none detected 0.02 p-Xylene ug/g' none detected 0.02 m-Xylene ug/g none detected 0.02 o-Xylene ug/g none detected 0.02 Total Petroleum Hydrocarbons ug/g none detected 0.6 (Gasoline) TEST METHOD: TPH by D.O.H.S. / L.U.F.T. method. Individnal constituents by Modified EPA method 5020/8020. As Received Basis Comments: California D.O.H.S. Cert. $102 ~.~. Eg~zn ' (~ ~Analyst e · ENVIRONMENTAL LABORATORIES, INC. J. J. EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., I~KERSFIELD, CALIFORNIA 93308 PHONE 32'/-4911 Purgeable Aromatics (SOIL) .... ~' 2 ;'~ -~ '2' '-2 f"Li' ~-- ~ __-_" ...................... ' 7808 Olcott Ave. Re~ort: 03-Mar-90 Bakersfield, CA 93508 Attention: Ken Olinger La~ No.: 1610-18 Sample Desc: Bus Barn by B.H.S. California Ave. & Campus Nay --' ............. : ..................... Middle Dispenser 6' Date Sample Date Sample Date Analysis Collected: Received @ Lab: Completed: 23-Feb-90 23-Feb-90 28-Feb-90 Reporting Analysis Reporting Constituent Units Results Level Benzene ug/g none detected O. 02 Toluene ug/g none de~ O. 02 Ethyl Benzene ug/g none detected 0.02 p-Xylene ug/g none detected O. 02 m-Xylene ug/g none detected O. 02 o-Xylene ug/g none detected O. 02 Total Petroleum Hydrocarbons ug/g none detected O. 6 (Gasoline) TEST METHOD: TPH by D.O.H.S. / L.U.F.T. method. Individual constituents by Modified EPA method 5020/8020. As R~ceived Basis Comments: California D.O.H.S. Cert. ~102 · ENVIRONMENTAL LABORATO RIFS, INC. PETROLEUM J' J' EGLIN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327-4911 MCNABB CONSTRUCTION CO Date Reported= 03/05/90 Page 1 7808 OLCOTT AVE Date Received= 02/23/90 BAKERSFIELD, CA 93308 Laboratory No.= 1610-19 ..... . ~.-Attn.,= ..BRYAN MCNABB · ..... 399-4742 ;~: ~-~;~*.~*~/~-'~-.~..~_~ ~v~:~ :;."-*:~-~'~::~*~:~'~-~-:~:~:~'~!'~'~ Sample Description: ~US BA~N ~Y B.a.S. CALIFOaNIA AVE.-CA~US WAY: WASTE OIL TA~K 2', 2/22/90 SAMPLED BY= ROY RHOADES TOTAL CONTAMINANTS (Title 22, Article II, California Administrative Code) ........ .~.. ......................... ~ ..................... ~ ..... ~* ......... *. Method ........ ~. ...... . .................. . Constituents Sample ResUlts .......... P.O.L. '~nits Method Ref. Lead 20.0 2.5 mg/kg. 6010 1 Oil & Grease 4621. 20. mg/kg 413.1 2 Requlatory Criteria Constituents STLC. m~/L TTLCr mq/kq Lead 5.0 1000. Comment= 'All constituents reported above are in mg/kg (unless otherwise stated) on an as received (wet) sample basis.. Results reported represent totals (TTLC) as sample subjected to appropriate techniques to determine total levels. P.Q.L. = Practical Quantitation Limit (refers to the least amount of analyte detectable based on sample size used and analytical technique employed. N.D. = None Detected (Constituent, if present, would be lees than the method P.Q.L.). I.S. = Insufficient Sample STLC = Soluble Threshold Limit Concentration TTLC = Total Threshold Limit Concentration REFERENCES: (1) "Test Methods for Evaluating Solid Wastes", SW 846, July, 1982. (2) "Methods for Chemical Analysis of Water and Wastes", EPA-600, 14-79-020. ENVIRONMENTAL LABORATORIES. INO. PETROLEUM J' J' EGUN, REG. CHEM. ENGR. 4100 PIERCE RD., BAKERSFIELD, CALIFORNIA 93308 PHONE 327..4911 MCNABB CONSTRUCTION CO Date Reported= 03/05/90 Page 1 7808 OLCOTT AVE Date Received= 02/23/90 BAKERSFIELD, CA 93308 Laboratory No.: 1610-20 .Attn. c BRYAN MCNABB -=~.399-4742. Sample Description: BUS BARN BY B.H.S. CALIFORNIA AVE.-CAMPUS WAY: WASTE OIL TANK 6', 2/22/90 SAMPLED BY: ROY RNOADES TOTAL CONTAMINANTS (Title 22, Article II, California Administrative Code) Method :'' ....................Constituents' ......... ='~--' ..................................' ...... S~-~es~its ...... P.O.L: ............... Units .................. Method"-- ......... Ref. .... Lead 7.65 2.5 mg/kg 6010 1 Oil & Grease 263. 20. mg/kg 413.1 2 Requlator¥ Criteria 'Constituents STLC. m~/L TTLC, mq/kq Lead 5.0 1000. Comment: All constituents reported above are in mg/kg (unless otherwise stated) on an as received (wet) sample basis. Results reported represent totals (TTLC) as sample subjected to appropriate techniques to determine total levels. P.Q.L. = Practical Quantitation Limit (refers to the least amount of analyte detectable based on sample size used and analytical technique employed. N.D. = None Detected (Constituent, if present, would be less than the method P.Q.L.). I.S. ~ Insufficient Sample STLC = Soluble Threshold Limit Concentration TTLC = Total Threshold Limit Concentration REFERENCES: (1) "Test Methods for Evaluating Solid Wastes", SW 846, july, 1982.. (2) "Methods for Chemical Analysis of Water and Wastes", EPA-600, 14-79-020. Section ~"?'V. ":f,:;~.[;,Authorized 'representative of contractor certifie's'' by si~ing-',belo~that::~j~T~[~:~::' ' :.~..:.,~-:~ ~:':;~:~.~. tank (s) . have been decont=lnated .In accordance ~!th' > Kern .'[County '~ealth ~}f~)~?,>? i~, ..~/:"?;,:',:~. tank(s)-have ,been decont~tnated In a~ordance ~tth ~rl 'r']~-'C":'"'..~' Depar. tnent requirements. ' -'.~:'..'~.}.. Lf:.~..-~ '...'... ~. .-:. "' ...... _ ........ ' · · ....... .-' ~ .".; '.. "i";:, ~ ; :.'; ";"7; ';' "';'";. ';~*" ",); :", :'-.' '; % ';'.'??", ~' ",i:' ~';i" ';. . ' · . : : ~ ; ~ ' f~ ,~" ~' ' '* .... · ' '-:" · ' -" ' '" '~' -'"-;'" '- -~;'"? '~' % '~ 'l..?~i,-,~,~.~i!.~ i~_'-". .. . ..... . .-. zip . · ~-~,, :';'-".. Date Tanks ReceiVed; :' ~. _'r .... : ~ -~ ~--'-':/-- ' : ...... .' ' .... ;[" ' "' "-: '"!.-~' ''-' ':: ::' " '' '" '~2"~ ': ':!' '.' , , - ' ' " ' ', -~i .... .,.· .f"4 ,',~---;;;'-- · ·'.L.. . ., , , ~; '.'rtl -' ' ','z '/% ---. ':'t~ ~.---u".~:'-"T.z-? ? ,~. : - . · e e ~ s, e e e ;.:- ~ e -~ --.e..e · -,~, .~.-. · - · - ~; .~ .~ ........ ~,. ~ ' ': ............. ' ....... :~-a ",'t ;,~;T ""~: '~ '~'~" ir'" ~," ' .'~-'~-'~ ~'":;' i':~a~lk;, ::~x' ' .~' ' '.': "" ~ ' :".,, .: '~' '~2" :,"'. ~-''- ,:;~i~:k~"['. :,. . .. . . . · .,,,;. . .. :.,.: ~:, ~.T ..... , C~~'' " (Form CYCL~G, TANK DISPOSAL FORM ' ..- O. DESTINATION: ·-: - A.M.R. 2202 8. Milliken Ave., Ontario, ~A 01761 SPECIAL INSTRU~IONS: TIME OU~ ~'::':, j Se~ices"Rendered "'~'- Cost · '~'~','¢"'~xtensive ~'ading ~m'e-:..'''' ;': · ::.':': l~.ffi F' O' f;~ '~::::~ '~'-'"~ ' *~'~'"'~':'~' ~ ' ' r J ;; ~'" ;: ' '" 2~ ~ ~ ,14 ' =' .FiberglaSS Tank DisposMFee ~'... -Fi~rglass ~ank' Oeliver~~..~:~..--.~-/;.'.'.:-"'.." 2ffi.ffi 2~1~ ~ O o .87.97 ~' :~btai! D~s~sal ~'~:~;~.LS:: :';,';- '.~: ~0.~ 2~ ~ D ~.~4 ~ Q O 1.32 6~ ~ Q 2.~ ~'"'::' ~TAL CHARGES T. $ ~ 7~ ~ o 3.26 ~ ~ ~ 3.82 All fees incurr~ are per I0~ unless specified. Terms are net ~ days from date of invoice. 12~ ~ D 4.~ Contractor's signature represents acceptance of terms for payment, and confirms that tank NO. OF TANKS TOTAL N~ ~NS ' . CONTRA~OR'S SIGNATURE 'F -- FIBERGLASS CERTIFICATE OF TANK DISPOSAL I DE~RU~ION THIS IS TO CE~IFY THE RECEI~ AND ACCE~ANCE OF THE TANK(S) AS S~CIFIED ABOVE. ALL MATERIA~ SPECIFIED HAVE BEEN COMPLETELY DESTROYED FOR SCRAP PURPOSES ONLY. J METAL ] 33807 .//I C¥CUNG, INC TANK DISPOSAL FORM :_..2202 South Milliken Avenue Date: ,,~.~ ~ ,19 :on/adO. 0A9176! ~:::~:~-::~:::~?"~:"~?-~::~:~'::~:::'~'-':~:~.~:~:.:-..~.~:j~b--~ :~ :~-:~:==--~:~.~:~=~::~:~ ..... (714) 988-8000 .. Re.# ADDRESS: JOBSITE; /~,,-/~1~/O/ /~Z_.Z~/~ ,.-~Z ,~~ /- DESTINATION: A.M.R. 2202 S. Milliken Ave., Ontario, CA 91761 TIME IN: · SPECIAL INSTRUCTIONS: TIME OUT: !. ,,, Services Rendered Cost - - .. Disposal Fee-2:; · ;: 200.00 TANKS RECEIVED . ::..{;~'~:.":'c~.? QTY. ' GALLONS TYPE NET TONS TOTAL ' E,xte_nsive loading ~me 150.00 F' S' "-:'~. · .':'-~< ~, -~" '"-' :~'.' :":'- ' . ' 280 [3 E] .14 ':'. "Dispo~! Fee with Permit 30090 500 ci 1'3 .21 .;.. -;.,~..~..,~.:½' ',.'-.... 550 D D .24 ~ ..Fiberglas,s :lank Disposal Fee Per Tank 400.00 ~' 1000.12 ;t. ' r3 ~ .44 . .:~ :c-.,--~:, ' ' ,' ~'!.: 1000.6 ft. r-1 I-3 .61 "Fibergl .a~s,, Tank Delivered 200.00 1500 E} [3 .87 ' . . , 20o0 [3 ~] .97 . : ";:.,.A-~-.. ~ '" '", .2500 E] i-3 1.14 : · Bob/ail Disposal Fee. ' 250.00 3000 1-1 CI 1.32 .... :" ';:'<"" ;"';: :-" 4000 I-t I::] 1.64 750O r't [3 3.26 .... TOTAL CHARGES $ + /- 8oo0 ~ ~ 3.~4 I~. gO00 [::] E] 3.62 All fees incurred are per load unless specified. ~ 10000 cI ~ 4.33 Terms are net 30 days from date of invoice. 12000 [3 E] .4.93 Contractor's signature represents acceDtance of terms for payment, ~nd confirms that tank NO. OF TANKS TOTAL NET TONS removal complies with State laws. CeNT,ACTOR'S} S~GNATURE *F'~ -- FIBERGLASS ~--- ~ CERTIFICATE OF TANK DISPOSAL I DESTRUCTION THIS IS TO CERTIFY THE RECEIPT AND ACCEPTANCE OF THE TANK(S) AS SPECIFIED ABOVE. ALL MATERIALS SPECIFIED HAVE 8FEN COMPLETELY DESTROYED FOR SCRAP PURPOSES ONLY. CONTRACTOR COPY ...... 2 C.K ~2759 ~ 4 100.00 E 400 ..00 3 ' TANK pLAN CHECK ~ ""' ?0A Onder Tota~ 5'00" O0 ~ Amount Due 500.00 ' Payment Made By Check 500'00. THANK YOU! TNT'~A[, USE ONLY; 2700 '~' STR~, ~[TE 300 L~I ~ ITaNX ~ ' vO~U.~ ~I~I~L ~nto (NON-CO~Z~L ~gS~ llOi RESIDUE IH T~(SI AND P~P~HG ~ ~ B~R~O~ AND OISPO~E~OP (INCLUDE ~PO~AT~OH ~t3 POR~ ., ,',~NPL~D ~R P~AL~ OF P~JU~ AND ~ ~1~ BB3T OP ~L~DG~ ~S ~Ug AND CDRRE~. PROVIDE DRAWING. OF PHY~. LAYCUT, OF .fACILiTY USU,:; __ ?ROV,IDED BEIZW. ALL OF THE 'FOLLOWING INFOi~IATICN MUST.BE INCLUDED l:I ORDER FOR APPLICATION TO BE TANK(S), PIPING & DI£PENSER{S), INCLUDIi.IG'LENGTH$ AND DIMENSIONS ':%/ ": _ PROPOSED SAMPLING LCCATIONS DESIGNATED BY THIS SYMBOL "(~. ~/ NmU~_~Z awa~ o~ ~Nrm~E~ON c~~ ' I~1 ~,o,~-w~.~~ I .. ~.~~.,~ ~~., . . samples retrieved from beneath gasoline~ samples retrieved from beneath diesel tanks and!.a ~urtenances. must: I ,zed' for total 11. Purging/Inerting Conditions: ~*.~' .-' .... ' ..... .." " .." :~ .... : . ~ . .:~.,~.a. . · . Liquid shall be pumped from tank prior to purging such that less than 8 gallons o~ liquid remainin tank. (C~H&SC 41700} .?~ .-. ...... d. ~,.~ No em~sston shall endanger the health, safer y, comfort of repose of any person. (CSH&SC 41700) ...... ~ ? ~...ic~.~ ...... ............ .~; ..... :~..a,~.· ~,.a...,,~:.~,~: . .i ..This department is responsible for enforcing the Kern County Ordinance Code, Division 8 and state regulations perlaining to underground storage tan '1~. -",' "~'. - 'Representalives from this department respond to job sites during tank removals to ensure that the tanks are safe to remove/close and that the overall ' job performance is consistent with Permit requirements, applicable laws and safety standards. The following guidelines are offered to clarify the interests .'i: I. ' Job site safety is one of our primary concerns. Excavations are inherently dangerous. It is the contractor's responsibility to know and abide by :;,, ,, .;';, CAL-OSHA regulations. The job foreman is responsible for the crew and any subcontractors on the job. As a general rule workers are not · .:- 'i'.~permitted in improperly sloped excavations or when unsafe conditions exist in the hole. Tools and equipment are to be used only for their designed 2. Properly licensed contractors are assumed to understand the requirements Of the permit issued. The job foreman is responsible for knowing and ~ : .- "abiding by the conditions of the permit. Deviation from the permit conditions may result in a stop=work order. -;,~:~,:-::.~,.'.-'?.,,~.~,,,.:i-~. '?~-,;;.:. ..' ,. 3. ~:' .Individual contractors will be' held responsible for their post-removal paperwork. " Tracking forms, hazardou~-~'~t'~'~nanifesis and analyses . '·.'?.~;i~.'..~!i?.'::;documentation is necessary for each site in order to close a case file or move it into mitigation. When contractors do not follow through on .~'1 ~i'-"{:i~,-".%'~?necessa~ paperwork, an unmanageable backlog of incomplete cases results. If this continues, Processing time for completing new closures will ~. .' ~ '~ .... . ...~-.' . . .... · . · :[. GARY J. WICKS "? ,' ' ... ~ ::'· ':.'·, <*":.~.' . ....... .' .'; ':'~ (805) 861-3~2 ~ ~ '.' .= '::.': .STEVE McCALLEY .... /~'~:~..'~::':.'~ ~" .' :~:..-:-.-F:- ::.~ ESOU'RCE NT ENCY C CLOSURE 'ERMIT.NUMBER ;RGROUND HAZ~ 'BSTANCES STORAGE FACILITY DRESS: District :Nabb,. /241 FOR 'CLOSURE OF, EXPIRES "4 TANK(S) AT ABOVE : )PROVAL ';.LOCATION Driggs ': :: '... "': : :.'...: :.'.: : : : ....... ~: ..... ::'.: OST ON PREMISES ..... ;: ............. ; .................................. ; .................. - ' ~' · :-' . ',: '.' ',."' 'i~."~': ."" ,' '..-' :-~-,' ' · - ' ....... ' .......' .... ' · ' ' ' ':"' "~ :::' ",. · ' ' -c~:[ . .,":'}.". , : :'~:'-'"~'"%+:'-'-"~'%;':?;~'~'~;%.::' 'c -' ,~ -~r , ~, .... ' : .' ,.' ¢ ',, ,:~' ,,. ,, 'V' ',.~ '~-' , ' ~'~**' · ?¢?'*' ''''r~ ..'~"'" '::';~'~'.:' ...... ND es onsibSilit of the Permittee to obtain permits which may be required by other regulatory agencies ~o~ to beginnin,~ wo~. (i.e., ,,-'~ ':'.' 1. . > It IS the r p Y , .~ .,~- --.- . .,, · .:'-,..-'. ,.:: ..,~.¢v .':..-.~::; L:t~%;..'.:: ':=~¢:.~; :,~.~,'"':.'~ .:;;¢'. ..... . .'.- (~'- Fire and Braiding Departments) -:.~::' "-.:.,':~¢." ..-.. :.-'~'..::.c?~; ............. - ............ '¢- .... :'~'*~:;'"~ ..... ,.:.~¢,,,..~,,i ....... i~'.,i!!:, -"!.:'i..;f .," ,. ' 2. Permittee must notify, thc Hazardous Materials Management Program at (805) 861-3636 two working days m'ior to tank removal or abandonmen: ' . . - ~ :' · - .:, 7 - -.,:::'":' ~ . .;'.,- ..:~*"'"",::.:": . in place to arrange for required inspcctions(s). ' ' 3. ' .Tank closure activities must be per Kern County Environmental Health and Fire Department approved methOds as described in Handbook UT- ..... . -. . - . ' · '.'...: ..... ' '?- . ,. ' L ~':' - L: ~ ":. :' ~' . '. ' '.'~ ' , ~' ' .~.:'30. . .": ~'::' ~ .... -: "". ?'. ~ '' .''" ~i='' .... '~'~ ":':"~:':~: ""'?~¢"~;:~ :_~i~::~.~'~..i: .;.~ain~ the h~i~diin~. ~ranso~tation or treatment of hazardou'. ' '-'" , ' ' ' *~, ~now aaa aanere to all ap[~l~l;uv~; ~awo ~,-~/,~-~ ~, ,=, -- . , ~ 4. : 'It ~s the coat po .... . ..... ~ ,.~ . ,,. ..... ~.?~,.~ ....:~,~..,.~,,. ~,......~.~: ~ ,.~ ~.::...~,: ...: , ", ".,'., -:'' · ' ' i ,: -: ' ... ,:L::' F, -~..~- ,' ~:' -:,,' -;~./;'~.l'~.}'.:':~,d ':.,,>:".' :,, ',.', ' " '.-.i, -'.' ': ': ...... ..... ~ , materials ' must have a Ualified company employee onsite supervising the tank removal. The employee must have tank remove · · 5. .;. The tank removal contractor q . . . , . . .., ........ :~.... ,..?;;-.., :~.?.:.:.{~,.¢.::,;.;-, ,,~:.,::.~; .,:.; ,~,,.,:,-. ,,,:;.. ...... 'ex crience rior to working unsupervised. ' ' :? ' :: . ' . . ' ' : · ' · b the s tall< :,~ 6 [f :ny contrP:ctors other than those listed on permit and permn apphcatwn arc to bc utxl~zed, pnor approval must be granted y pec . · n from thc submitted application is not allowed..:,,. ,~,., ', ;, v~..~.,~;,~:>~.~_.',,-;-~,¢.~..':'¢.';c :~ ,~:' ~: <:-:...~'~'~:;~;~.~.:. ~-':i'.. ,~..-:.'.~ ,' · · ' . "~iisted on the pormfl. Dewatw . .. ....... . ,.;... .~; .... ,..:.; :.' ..:...!.i,:::::~.i?-.:. :>¢..?d.;.?..:&~-~.~:i~,, :,~ .h.,.,=?~.:.:,.,,,~ :' ~i "? ' ':' Soil Sampling: .... ' ~.:!" :.*:~¢? . · ''''~,'': ':' '"! "':"-':":Y" "::'" ':'"'! ;' -:" , :' "' _:':,_~ :..::'~:~ctri~'e~ ft:om beneath the ~nter o[ the tank at dept :~ · : :'-' '~' · ual to L000 gallons -'a mimmum or two samp~c~ tuu,~ ~ · '::,;.. :.,-. ~;/,~,,:a. ,. ,.:,, ,~. Tank Mze less than or eq .... _. . .... . .,.,, .... ...:.. ,,...· ~,, ~..~....~,.:,.,. ,.~.4¢:.... ,,;.,, ...F:?~:,,.~:,~:::.~,;..-,. ,,.~:.:.: , ',~i"-/rc!~:~:~'~:";:!;'~'~"N:';:.'2~i;'.:(S~'o[ approximately two feet and six feet. 9;-::'-;.:,.%;;~,.".~}:?.:.~'~.,.':~;{ '::'*.:!:-:f '"{' ?'¢,:','_?~'~'::"~:':¢~,~'~:~:~'~.:'. '"; d ~ ~*~'in fro~*t'he ends( ~':' "~"%~,!"'"::'¢= ' '" ~*"4¢~¢':" .,.'~- - o 10.000 allons - a mm~mum o[ tour setup,es mu " ...... 7,- ,~-- ' ...... . "~.;,: ..... ,~'~, .... """ .... ', .... b ~" .... T..k size greater than 1,000 t . g _ _ . ........ . ....... ;.,~``~.;~`~.~.~;..~`:¢r¢`~:<~,~`~:~`*~:~:¢`~.P`:¢~`.~ ,...., ' , . .each tank at depths of approximately two teet and slx feet. -,".., ..... .' ,'. '<" ~'" '='*'"~'-~';'~'"; ~¢~.~';' "; '" ¢.',~'~" ~:~ "-" 7-..-...~ 7,.~ .,,..~: ......... . -, : ;! ;~:" 'i' ', :' ', ize ter than .000 gallons - a minimum of six samples must be retrieved on-[out'th of the way in from the ends ,3[ each ta~ '~" . .-, c Tank s grea 10 - . · ·: ~-,:-..~. ,,....,~. ~. ,:,,~0,,:: ~,, ~,:- - .-,,~,.~'~,~:~'~.:~ '.~-~:,i,~: :.,.,,: ,~, .. · ~/~ ..... "~'"" off Sam hn ( i lng area): .?~!~.:C.:~;~i~f~?~:~:~`~Z:;~:.¢~?.`:.~f:~.?.%.``~F.~:~.`~:::~..~`.`;~?~ ';'~ ~': ..... '~' "'" ": ' '~ ~=: '" · 'feet of ~ 'run and under =,~-.. ....8. ~ S P g P P ..... t and mx feet for ev 15 hnear p pe ~ .. · a rommatel two fee ery · , .... · ,; '"' .' '"' "A minimum of two samples must be retrieved at depths of pp Y .... .. , .... Ca ..~ r..~,- .... ,..?.,,,:,., ~,,~; · -., t,~,~-· '-. · ' . · * · ' · , ,, .. ,+ .., , -, . ·., - , . . 1.1.' US DOT Deecriptioa (Including Prope~ Shipping'Name, Hazard ~ earl ~ Number) ...: 2.';~?-'~:.. ' ~ ... Quantity . EpAIO~h~ C. EPA/other d. state -:~ - ...... EPA/Other J. AddJtioe~ Delc~l~ae fro' Materials Listed Above ~ t~ Wastes Listed Above c. .. ;;?: :..'....'? ... 16. Special Handling Insimctio~s and Additional Infom~ation · ...~-: .: /,. .. ~.. :- ? . 2~.: .:.' T / ~,.'~.- /-":"/,:.' ~.- 16. GENERATOR'S CERTIFICATION: I hereby declare that the contents of this consignment ars fully and accurately described above by proper shipping name and are classified, packed, marked, and labeled, and are in all respects in proper condition for transport by highway according to applicable international and national government regulations. If I am a large quantity generator, I certify that I have a program in place to reduce the volume and toxicity et waste generated to the degree I have determined to be economically practicable and that I have selected the practicable method of treatment, storage, or disposal CUrTently available lo me which minimizes fha present and future threat to human health and the environment: OR, if I am e small quantity generator, I have made a good faith effort to minimize my waste generation and select the beet waste management method that is available to me and that I can afford. Printed/Typed..e. Name I[ Signature.,~T,..~ ,'.~ , ..". . ~fa' f ~ Month Day Year 17. Transporter 1 Acknowledgement of Receipt of Materiels ~ ~ Printed/Typed Name:? Signature **~ Month Day Year .* .~. -. ~ ~::. ,; .F,.-':' ~ 18. lransportar 2 Acknowledgement of Receipt of Materiale Printed/Typed Name I Signature Month Day Year 19. Discrepancy Indication Space 20. Facilify Owner or Operator C. ertlfk~tion of receipt ot hazardous materials covered by this manifest except as noted in Item 19. Name * - .-.. .... . ' ............ . . ..-.- ;~F'~ ? - - I--I-'-t t I' . ' ,,. - '.' Do NOt Write Below This Line ~" .' '- .:' DHS 8022 A (1 / 88) . .. ~ ~J:, · - ·" EPA 8700---22 ' (Rev. 9-88) Previoua editions are obsolete. ' ' "' "' - ::" '; ·" . ' ' ::' · ,~' '...r . . · ':. ..... ' ':.?-j'" . GREFN: HAULER',x 1450 W. MCCOY SUITE A SANTA MARIA. CA, 9345S ~'EUM ECLUIP~ENT INS'~ (805) 928-1135 AUTOMOTIVE - INDUSTRIAL ""~" :PETROLEUM 20'80 SOUTH UNION ,' MAILING ADDRESS EQUIPMENT BAKERSFIELD. CA. 93307 · PHONE 834-1100 P.O. BOX 640 INSTALLATION - MAINTENANCE CALIF. CONTRACTORS LIC. # 294074 BAKERSFIELD. CA. 93302 n KERN HTGH SCHOOI_,'DISTRIC ~'?..; 1-720'.!.--] S4271 ATTN ::BEN SEYKORA '- '2000 24TH STREET, BAKERSFIELD . .;. CA 9;3301- Wi]RI& PERFORt'It':..IiI-L;HE[SKED UI/I'I'(AIJ. UN Ul" UA~.UUY l.IJ. bbbL R5 I~EL~UI:.31ED REF'LACED FILTER 'AND tViADE REPAIRS AS NEEDED, -CHECKED FOR "' ... PROPER OPERATIONS. .: MATERIAL: C.~TY PART :11: DESCRIPTION PRICE 1' ' 242:337 ' :l. 0015 ~.'10 EHPEROR T. FUEl_ FI 489,90 "244076.' LEO5 ::;'.. EHPEROR REF'LACEHE 101,:34 ]. 092288 020 .1.611 ~ NIPPLE J. X CLOSE'" 0,74 & 09:~:1.47' WS:I. 4.:.~. ' CONCRETE BOLT 1/4 4.50 2 0c?2096 '38:3G '~'~ BUSHING 1 1/2 X 1 5,64 ;,~:":!::-:,!r~:~''''' :"-'"~'=""~/-" :" ";' "":':~ ~'~:~:,~i ,''r ::-- ........ ' ~ ..... ,. ',:- ~,¢ ...... :,:,.< ......... .. WO'# &"'J,-~-~--"-~-, ~2_.z.,~,,.,~47-- ~ LABOR: ~.25 97. · .- v - ~/ ~_~ MILIF. AGE: 10 5. MATERIAl_: 60~3 SUPPLIES: 7. ~ SALES TAX-- .' TOTAL: 74~. PLEASE PAY FROM THIS INVOICE TERMS: NET 30 DAYS A BINANCE CHARGE OF 1.S% PER MONTH WHICH I$ l~% PER ANNU~ CHA~O~D AF?~R 3~ DAYS. IN ?N! EVENT OF ANY LAW~UI? OUT O~: ;HIS TRANSACTION TH~ ~E~¥&IUNG PARTY SHALL EE ENTITLED TO EECO¥ER E£A$ONARtE AI3ORNEY'$ FEES. ALL MEECHANOI$E RFJaAIN$ TN~ ~EOPEI~¥ OF RLW EQUI~MEN? UN;IL PAID FOR IN F~LL. A RE$;OCI(INO CHARGE OF NOT LESS THAN ~0% WILL EE MADE ON ALL I?E/g~ RETURNED FOR CREDIT WNEN ERROR I$ NOT OUI~. ~ATERIAL RETURNED WILL NO? RE Accr~TED A8TER 3~ DAYS. ~LAI~$ ~OR SHORTAGES MUST BE/trADE IMNtEDIATELY UPON RECEIPT OF GOODS. ORIGINAL , .. CO.PU~E. C-'HA"GE Fl C^LmATIO~- Record of Computer C~ige, Meter Change, or Calibration PUMP-MAKE A~Q MOOEL TOTALIZER . u'. ~ I ---- ~qo ~ooucr. "TOTAL GALLONS RE~RNEOTOSIORAOE CHECKED ADJUSTE~ TO ] - . CHECKED ' F. INISH$ ~ J I AOJU~ TEO TO TOTALIZER CHGCKED AOJUS1 ED TO ' CHECKED [ * ' AOJUSTED TO TOTALIZER FINISH READINGS MONEY TO?AUZER S~[ED IMETER SEALED o~, 'Pump ~ TBTAL " _l ' O'~s O"° ~~ ~ ' , ~ , 1 seu,~i NUMU~ CHECKED ADJUSTED TO TOTALIZER _ ;~t[,~s .............................. 110 IAI.IZE"-- U~ ALtO . METER SEALED ...... · READINGS ' ';~'~'--1'°Nc' ..................................... I OY,S ~NO ~,Es COM~TE. CH^N~E r"] cAu.^TiON ReCOrd ct Computer cWnge, Meter Chsng., or C"llbr. tlon I sEmac NUM~E~ CALIBRATION CHECKED A~uSTED TO ~Q~kO~ FAST , BLOW F~T ~kOW · NU MOU~L ; .~ SERI~ NUMBER CALIBRATION ' ' ' - ' ': CHECKED ~STED TO ~oo~c, , Pump ~ r'TOTAL .. , ~uu~.u,~t ~-o ~oott c. CALIBRATION CHECKED FINISH TOTALIZER . ..<~: · CHECKEO AOJUST~TO FINISH [ ~OrALIZER ~MP-MAKE ~N[TMOOEL .]~ER1AL NUMBER CALIBRATION I CHECKED * A~U~TED TO TOTALIZER FINISH READINGS ~NEV ~LLONS rO~AUZER S~LED METER CHECKED I A~USTED TO READiNG'S-- MONEY - - ~LLt)NS ...... I1OiAt.,zta ~AL~O · MET~ ,~o~c, Pump ~' TOTAL ~o · .MEMBER PEI' ~'EUM EQ.gIPMENT IN%'q AUTOMOTIVE o INDUSTRIAL PETROLEUM 2080 SOUTH UNION MAILING ADDRESS EQUIPMENT BAKERSFIELD. CA. 93307 · PHONE 83~,-110Q P.O. BOX 640 INSTALLATION - MAINTENANCE CALIF. CONTRACTORS LIC. # 294074 BAKERSFIELD. CA. g3302 · F~I RN HIGH SCHOOl_ DISTRIC 1720 S3744 ATTN:BEN SEYKORA 2000 24TH STREET. 'LB~KERSFIEI-D CA 9~01- - ] .BUS BARN WORK PERFORMED-CHECI(ED AND CALIBRATED FUEL DISF'ENSERS AS RE- QUESTED--CALIBRATION OKAY--NO ADJUSTMENT NECESSARY. FOUND METER LEAKING--UNABI_E TO REPAIR--REPI_ACED AS NEEDED--RECAI_IBRATED-- FOUND NO. APPARENT LEAKAGE--UNIT FUNCTIONING PROPERLY. MATERIAL: QTY PART ~ DESCRIPTION PRICE 1 .052670 B14&O 12 I_IEAD/WIRE.METERSE 1.00 1 .322761 PA24LXE~...MET, ER .152.27 LABOR: 4.00 120 MILEAGE.: 21 10. MATERIAl_: 153. SUF'PLI ES: 2. · "" " .':"~'[ ' : SALES TAX: '-- TOTAL: 2~. · '"!.PLEASEPAY FROM THIS INVOICE TERMS: NET 30 DAYS ORIGINAL [~COM'PUTER C~IAHGE LIBRATION ' Record of Computer C ge, Miler Change, or Calibration F~JMP'~aAKE AND MODEl. ' u I SEmAL NU CALIBRATION - 'READINGS Uo~Y TOTAUZ~. S~AL~D TOIALIZER IPump f TOTAL . .uuP.u~,<e ^.u ~O0~L SEm^L .UMBL~ '"'= CALIBRATION .' . : CHECKED ADJUSTED TO, TOTALIZER · MONEY GAt t ONS TOTA~Z~R St~O UETER 'UMP UAl[ ANI' ML*UL[ nlAC "UUO~" CALIBRATION ~ ' "'" CHECKE~ ADJUSTED TO FINISH TU~ALIZER READINGS ~)NI.Y liAI I ()NS IOIALIZ[H ~lAI LI) MklLfl SLALfU START. D'" D"o D'" D"° "'":'":' ~ump ~ TOTAL GALLONS RI ~URNFD TO ~MP-MAKE AND HOOEI lSERIAL NUUOtR CALIBRATION ' I ' .' CHECKED · A~USTED TO TOTALIZER FINISH :'.. 'AST ISLOW FAST READINGS GALLONS ~O~Z~ S~LEO ME~ ST~T ' D "' O .o D ~T GALLON~ R~URNEO TO ~M~' MAKI AN[) MUOCL SERIAL NUMOEH CALIBRATION CHECKED I ADJUSTED TO MONEY I~CCONS FAST ~SkOW F~T TOTALIZER FIHISH .. · START D YES ~ NO 0 '~ D NO ..o,,~c, pump ='~' TOTAL ~.,,o.~ RETURNED '0 '~"~'*~'~"~" ' I~*'"~'*~'~¢Y~ k~ ' / ~'~W ME~R CHANGE /M NOTIFIED FINISH ~ t ~' TOTAL..... : , ~. s~ ,uuBe~ CALIBRATION ....... ' '/'". " " ; .. · , CHECKED ~STED TO Pump ~ TOTAL -. PUM~.U*I<E ANI)MODEL SERIAL NUMBLR CALIBRATION . -' .... CHECKED ADJU~ rED TO. TOTALIZER .:f" ";FINISH READINGS MONEY GAt I (~NS ' < ---- [OTALIZER SEALED METER SEAl. ED ~ump ~ TOTAL r'u ,.,'TO rALIZERUA" [ *Nr ~L'ULL ilS( CIAL NUUm R ~/ IS CALIBRAT ION CHECKED AOJUST ED TO FINISH MONEY GAL L~)N~ ~Aur LOW F~ 15LOW I ^NU MODEL SEm^L NUMeER CALIBRATION ,. ~' CHECKED · ADJUSTED TO TOTALIZER FINISH .'"'"- ''''~ · {..:.~,...~.' . , . READINGS . ~NEY GALLONS ~ ~TER S~LEO P~T*. GALLONS RETURNED TO STORAGE ....~ . .... .-' · CHECKED A~USTED TO -., ...... TOTALIJER READINGS ~NCY GALLONS 10 IAI.IZER ~rA~EO , I ~o,,~c, P. ump "~' TOTAL ,ED ,o '2 <...,J':_' ~..~ ...... ,__ ...... f , ,:..,,-,.._. AUTOMOTIVE - ~NOUSIRIAL PETROLEUM 2080 SOUTH UNION MAILING ADDRESS EQUIPMENT ~AKERSFIELD, CA. 93307 · PHONE 834-1100 P.O. BOX 640 INSTALLATION - MAINTENANCE CALIF. CONTRACTORS LIC. ~ ~94074 BAKERSFIELD. CA. F'AGE 1 ~ 10/06/8F] A'TTN:B',=ZN ' ....' '"'" ~]~()O0 24TH ST:~E~T F~,.~,'.~,~I...~.I ~. 9330:L- c, LJ.., ~.~-~kN ~.,~1~ ~ ' ~'' ~' ~ r' ~ ~" ~ '~" '~ '" ~ CD CANNON ~0Fd~ ~"c -r' '" "~ '~ ~'- i ,- ..... ~ · ~S PIER F :.,~1 .JRH,=E,-t~,~, I._-(..,z[ DZ~- c ~ ' ~ ' OI:'ER~T]ON ~Y PUHPZNG FUEL ZNTO BU~. CHECKED OUT OKAY. C~TY P~RT '~' DESCR~F'T~DN F'R~CE ~ 092094 ~o~,-~,~o BUSI-IZNG ~ 'X 'S/4 S 3. ~ 23005~ FLEXSTEEL HOSE 3/4' X ~'~ ~ ~0.54 L~:~:~ :"~','~"~"~,~,,.,~?~,,,.. ,.:,..~ :,.~ . ,, ..... ~ , .~., .: ~' , :.., . : ,.. ~::,,~ ~ .. ~:~ ...... ~,,~ .- .... ~ ~ ................ ~.,., . ~'~::.~:~ ~'?~.?~'~'~ '~.~ ~- ??.:-~- , .;..:=. :~, ~ ...... . ....... ::~ .~.... ~:~ .~.,.-~ ,..~ ....,.~: .... ~ I_ABOR: 1.50 45. MILEAGE: 10 5. MATERIAl_: 34. SUF'F' "-c' 0 SAL. Eo TAX: ~. TOTAL: 86. PLEASE PAY FROM THIS INVOICE TERMS: NET30 DAYS . ORIGINAL AUTOMOTIVE - INDUSTRIAL PETEOLEU~ ~O80 SOUTH UNION MAILING ADDRESS EQUIPMENT BAKERSFIELD, CA. 93307 · PHONE 834-1100 P.O. BOX 640 INSTALLATION - MAINTENANCE CALIF. CONTRACTORS LIC. ~ 294074 BAKERSFIELD, CA. 9330;~ P~GE ~ ~ 05/23/S8 'ATTN:BEN SEYKORA 2000 24TH STREET BAKERSFIELD ' CA 93301- 1200 B STREET L WORK PERFORHED-CHECKED AND CALIBRATED ALL PUHPS--ADJUSTE~ UNITS i AND 5 AS NEEDED--REPLACED METER ON N0.2 REGULAR AND CLEANED STRAINER. CHECKED ALL PUHPS FOR PROPER OPERATION MATERIAL: QTY PART · DESCRIPTION PRICE 2 052~Y0 B14&8 i2 LEAD/WIRE flETERSE 2.00 i 322~&i PA24LXE~ HETER i52.27 LABOR: 4.00 12C MILEAGE: 22 11 MATERIAL: SUPPLIES: 2 . . SALES TA~: S TOTAL: 27E -PLEASE PAY FRO~ THIS INVOIEE TER~5: NET 30 DAY5 ORIGINAL :' .,~ COM.UTER CHANGE r"l CALla~. Record of Corn nange, Meter Change, Or Calibratlc D METER CHANGE~ ['--'J ~NIM NOTIFIED OATE DIEPATGH NO. ~UMP~E AND MOO~.. s~14~ NU~.~ CALIBRATION ~ ~kO~ FAST F~T I ~LOW I ~ ' G~[~ TOT~IZER ANO ~OEL S~I~ .~aER CALIBRATION READINGS u~ ·. ~LO~ ~Q~T RETURNED TO STOOGE SEm^L ~UMSLR CALIBRATION · / CHECKED/ ! ADJUirEU TO. FINISH TOTALIZER READINGS ~Y IGA{ I DN~ IOT~IZERyEsSEALED METER 3E~.EO ST~T O O"o I O" O.o L .TOTAL UP.MAX E ~N,, MUUL~ st ~. NUMaF. R CALl BRAT ION CHECKEU AOJUSIED TO II'UrALIZER FINISH F,L LON~ ,A=I [~UOW F,~I I~LOW LREADINGS MONEY li~ I (INS ; IOIALI/[H ~AI ~U Mkl LR ~LA[[U I~l)~'~ ' ~tl. ON5 RLTURNFD TO :;]~A~¢ ' MOOEL ~m~ N~eE~ CALIBRATION ~ CHECKED * ADJUSTED TO FINISH TOTALIZER I I ST T YES D D'' D' ETURNED TO STORAOE l ~u~. ',-,,~c ANn MODEL · ,MO~R CALl BRATION CHECKED ADJUSTED TO ' ...... I ]MO.EY !GALLuNs F~t ',~Ow .~t Is. Ow I TOTALIZER I FINISH I ' -- ] * 'l METER CHANGE ' O ~A~/M NOTIFIED MODEL " ~ ~ ~ ~' CHECKED ADJUSTED TO '. G~L~ UET~ CHECKED ~JUSTE~ TO READINGS ~NEY ~LLONS . · . METER ~EALEO ~OOUCT TO STORAGE ID MOOEL SERIAL NUMBS. CALIBRATION TOT.ALIZER ~ -- q - ~ + I READINGS START ~*s ~ ~ NO cHEcKEU ADJUSTED TO FINISH -. , ' TU rALIZER .. READINGS MfJN~Y (iAI I ()NS IOlAL II[N ~lAI ~l) MkIER START ';~ ~ YES ~ NO ~ YES ~ NO ~,,,.,,. ~ Pump ~ TOTAL G~.,o.s.~,~...=,o=~,o.~ - ~MP-MAK~ ANU MODE lse.,,L NUMBER I CALIBRATION[ CHECKED i · ADJUSTED TO e ~NEY ~LLONS CA~T laLOW F~T SLOW TOTALIZER FINISH READINGS ~Ne~ GALLONS TO~IZER S~[ED IMETER ~LED ST~T ' 0 YES 0 NO O Y" O ~ .~ 'Pump ~ TOTAL .... G~o~s,~u,~Eo,os,o~o~ ' ~M,' U'K~ AN[~ MODEL ISE.,Ak NUMO~. CALIBRATION I CHECKED ADJUSTED TO . ~,JOTALIZER FINISH . . , START [ ' Oyes ON0 ~.~ ..o,,~, ' Pump .'~'1 TOTAL - ' ~o.s.E,~..~o ,o t. All meters must have calibration checks a minimum ol' twice a year, Which may iinclude checks,]done by the Department of Weights and ~easures. a. /Before startln8 calibration runs. ~et the, calibration can ~ltb produce-and ~.return produc~?to storaie. 3. ]Run 5 ~allons? with nozzle wide open Into the can. Note ~allons and cubic ?~lnches drawn, and return product to s~ocage. .- ' 4. ~.Run 5 ~allons~wlth the nozzle one-hall o~en into t~e can. Note ~allons and .. u'cubic inches drawn, and' return product to storas~. ' 5. j After all product for one calibration check Is returned to storage 'remember ~to record the volume returned to storage in column 9 of the Inventory : j~Recording sheet. 6. ~Ig the volu~e ~easured In ~ 5-gallon calibration can is ~ore than 6 c~blc t: inches above Or belo~ the 5-gallon ~ark. the ~eter requires calibratio~ b~ ~ ~:reglstered de,ice repairman. 5, :.,,.Date/Ttme[~Ose or TankFast~:~lo~~[ow ~low Vo~se Returned CalibrationDevice RepairmanOa~e Pu~p Product lion Ion ~ca~t to Storage Required? Used got t ;allbrati ~ { ~ ~ [ache [ Gallons Yes ~o Calibration O-aer or operator signature .. ~ .~ UBMIT A COPY OF THIS FORM WITH ANNUAL REPORT Facility: ._ ,ct ~c.~ Permit ~ _ /~)~ //~~ ~ Note: I~. Ail meters must have calibration checks a minimum of twice a year, which may u Include checks done by the Department of ~eights and ~easures. ~. Before starching calibration runs ~et the, calibration can with product and , return product to storage. 3. Run 5 gallonz ~ith nozzle ~tde open into the can. Note gallons and cubio .~ Inches drawn, and return product to s~orage. ~. Run 5 gallons with the nozzle one-half open Into th'e can. Note gallons and ~ cubic inches drawn, and return product to stocage. 5. After all product for one calibration check Is returned to storage, remember . '~'~ to record the voluae returned to storage la coluan 9 of the Inven~org .~ Recording Sheet. 6, If the volume =easured In a 5-gallon calibration can ts more than ~ cubic ~; inches above or below the 5-gallon =ark the meter'requires calibration by a ~ registered device repairman. Date/Time Hose o~Tank ~/ Fast Flow Slow Flow Vo~me Returned Callbvatlon Device Repatr~an Date of Pump Product 5-~allon Draft 5-Gallon Draft to Storage Requtred7 Used for ~ Callbratl I Cu. Inches Cu. Inche Oallons Yes No Calib~atlon Il~ ,. I ~[~ ~ ""'.2~.~~ 0 ~ ~ ~ ~ ~ i.' Owner or OperatPr St'gnatu.~e Calibrator's SiEnatur, _ ~~ ~ ~~ 'Registration ' ~-~;~~" .~ ANNUAL TREND ANALYSIS SUMMARY TANK ~ 3 TIME PERIOD: May 1988 to April 1989 QUARTER I TIME PERIOD: Mey l~m8 tO July !9EE ................. PERIOD-..I: ..... Total Minuses This Period (Line S) 12 PERIOD Z: Total'Minuses This Period (Line 3) ' 21 ...... -~. Action Number for this Period (Line 4) 37 ,,,:~ERIO0 3~ Total Minuses This Period (Line 3) 29 ............... '. !u:i_. ': .... : Action Number for this Period (Line' 4) 54 QUARTER 2. TIME PERIOD: ,August 1988 to October 1988 · PERIOD 4: -Total Minuses This Period (Line ~) 41 Action Number for thi~ Period (Line 4) 69 ' PERIOD 5: Total Minuses This Period (Line $) 49 Action Number for this Period (Line 4) 85 PERIOD $: Total Minuses This Period (Line 3) 60 Action Number for this Period (Line 4) 101 QUARTER 3 TIME PERIOD: November 1988 to January 1989 PERIOD ?: Total Minuses This Period (L~ne 3) 68 Action Number for this Period (Line 4~ 117 .. PERIOD 8: Total Minuses This Period (Line ~) 78 Action Number for this Period (Line 4) 133 PERIOD 9: Total Minuses This Period (Line S) 87 Action Number for this Period (Line 4) 149 QUARTER 4 TIME PERIOD: ,February Ieee ..... to .. PERIOD 10: Total Minuses This Period (Line · ' .Action Number for this Period (Line 4') · PERIOD 11: Total Minuses This Period (Line 3) lQ7 Action Number for this Period (Line 4) ]80 , PERIOD 12: Total Minuses This Period (Line 3) 115 ........................................................ Action.Number for this Period (Line 4) 196 I hereby certify this ~a true and accurate report. // .- ANNUAL TREND ANALYS I S SUMMARY TANK ~ .. 2 TIME PERIOD: Ma~ ]98~ to April ]OSO QUARTER 1 TIME PERIOD: __~.]gR8 to 3,,7y 19~9 ~.~-.?-ERIOD 1: Total Minuses This Period (Line S) ......... :: . .: ~ ...... "---'-- ::' - ~ '?'7'3"~-.~ fl - ~-/ZZ 7ZZL:f L.T'/fL:7'.~:- .~---: PERIOD 2: Total Minuses This Period (Line 3) 24 ..... :. Action Number for thi~ Period (Line 4) PiRIOO 3: Total Minuse~ This Period (Line 3) 29 Action Number for this Period (Line 4) 54 QUOTER 2 TIME PERIOD: ~,,~,,~t ]9~ ,, to ~,~ .PERIOD 4: Total Minuses This Period (Line S) 37 Action Number for thi~ Period (Line 4) 69 PERIOD 5: Total Minuses This Period (Line 3) Action Number for this Period (Line 4) ~5 .. PERIOD 6: Total Minuses This Period (Line 3) Action Number for this Period (Line 4) .. 101' QUARTER 3 TIME PERIOD: N~v~mh~r 1Oa~ to PERIOD 7: Total Minuses This Period (Line 3) . 66 Action Number for this Period (Line 4) 1],7 " PERIOD 8: Total Minuses This Period (Line 3) 79 Action Number for this Period (Line 4) PERIOD 9: Total Minuses This Period (Line 3) 87 Action Number for this Period (Line 4) 149 QUARTER 4 TIME PERIOD: February ]OSq to April ]QRQ PERIOD 10: Total Minuses This Period (Line 3) ~ .Action Number for this Period (Line 4') 165 PERIOD 11: Total Minuses This Period (Line $) 105 Action Number for this Period (Line 4) 180 PERIOD 12: Total MinUses This Period (Line 3) 113 ...................... £ .......... Ac.tion_,Number for this Period (Line 4) 196 ! hereby certify this is a true and accurate report.' ANNUAL TREND ANALYS I S SUMMARY TANK =. 1 I. TIME PERIOD: ~'7 ]QR~ to Aoril 19~9 QUARTER 1 TIME PERIOD: ......................... pERIOD 1: Total Minuses This Period (Line 3) 9 PERIOD 2: Total Minuses This Period (Line 3) 16 · e Action Number for this Period (Line 4) 37 '!iXPERIOD 3: Total ~inuses This Period (Line 3) 26 Action Number for this Period (Line 4) 54 QUARTER 2 ' TIME PERIOD: pERIOD 4: Total Minuses This Period (Line 3) 34 Action Number'for thi~ Period (Line 4) 69 PERIOD 5: Total Minuses This Period (Line 3) 47 Action Number for thi~ Pc'tied (Line 4) 85 PERI6D 6: Total Minuses This Period (Line 3) 59 Action Number for this Period (Line 4) 101 QUARTER 3 TIME PERIOD: Nnv~b~r ]ORR 'to .3anuar7 1989 PERIOD 7: Total Minuses This Period (Line 3} 70 ACtion Number for this Period (Line 4) 117 " PERIOD 8: Total Minuses This Period (Line 3) ~8 Action'Number for this Period (Line 4) ,]~3 PERIOD 9: Total Minuses This Period (Line 3) 9~ Action Number for this Period (Line 4) .149 QUARTER 4 TIME PERIOD: Fcbruar7 !989 to April 1989 PERIOD 10: Total Minuses This Period (Line 3) 107 ' .Action Number for this Period (Line 4) PERIOD 11: Total Minuses This Period (Line 3) 117 Action Number for this Period (Line 4') PERIOD 12: Total Minuses This Period (Line 3) 127 ................................... L ........... Action Numb.~_ for this Period (Line 4) 196 ' I hereby certify this~ts a.true and accurate report. Stgnature '" ~:--- ...... Date ~TANKhm~He~ FACILITY ~qNUAL REPORT ~n C~.ty He~ D~t Facility Transportation Permit ~ 160010c Month/Yr.. April 1989 1. I 'have not done any major modifl~atlon~]to this~facility during the the Permitting Authority. 2. I have done major modifications for ~hich I obtained' Permit(s) to ,.,._Construct from Permitting Authority :~Signature. '" Permit to Construct ~ Date ~ ..... ~e~aff'and~Maintenance SUgarY TM ...... ~'~ ........ ' ........... ' ......................... "' Attach a summary of all: -~ Routine ~nd required maintenance done to this facility's ta~, piping, and monitoring equipment. -- Repair of submerged pumps or suction pumps. -- Replacement o~ flow-~estricting leak de~ectors wi~h same. -~ Repair/replacement of dispensers, meters, or nozzles. -- Repair of electronic leak de~ec~ion components, or ~eplacement with same. -- Ins~allation of ball float valves. · -- lnstallation or repair of va~or recovery/vent l'ines. Include ~he date of each ~epair or maintenance activity. NOTE: Ail repairs'or replacements in response to a leak require a Permit ~o Construct from the Permitting Authority as do all other modifications to ta~s, .piping or mon,itoring equipment not 'listed here. 4. Fuel Changes - Allowed for Motor Vehicle Fuel 'tanks Only. List all'fuel storage changes in ~anks, no~ing: Date(s), tank number(s), new fuel(s) stored. NONE 5. Inventory control monitoring is required for this facility on -the Permit to Operate, and I have no__~t exceeded any reportable limits as listed in the appropriate inventory control monitoring .handbook during the last twelve months (if not aJafj~icableo,~disregard). Stgnature~~.~._~///// ' 6. Trend Analysis Summary Please attach Annual Trend Analysis Summary for the last 12 periods. ............ . ...................... ~ .... ~e-~r-Ca~ibr~t.f~.n._.Ch~k..Form Please attach current, completed Meter Calibration Check Form T~d~K FACI LI TY ANNUAL REPORT Facility Kern Hi~h School Dist. Permit ~ 160010C Month/Yr. May 1988 1. ~i have 'hot done any major modifications to this facility during the ........... ~'i .................. Signature the Permitting Authority. 2. I have done major modifications for which I obtained Permit(s) to .~,Construct from Permitting Authority ....~ Signature " Permit to Construct # Date Attach a summary of all: -- Routine and required maintenance done to this facility's tank, piping, and monitoring equipment. -- Repair of submerged pumps or suction Pumps. -- Replacement of flow-restricting leak detectors with same. -- Repair/replacement of dispensers, meters, or nozzles. -- Repair of electronic l~ak detection components, or replacement ',':-- Installation of ball float valves. -- Installation. or repair of vapor recovery/vent lines. Include the date of'each repair or maintenance activity. NOTE: Ail repairs or replacements in response to a leak require a Permit to Construct from the Permitting Authority as do all other modifications to tanks, piping .or monitoring equipment· not listed here. 4. Fuel Changes - Allowed for Motor Vehicle Fuel Tanks 0nly. List all fuel storage changes in tanks, noting: Date(s), tank number(s), new fuel(s) stored. 5. Inventory control monitoring is ·required for this facility on-the Permit to Operate, and I have not exceeded any reportable limits as listed in the appropriate inventory control monitoring handbook during the last twelve months' (if not applicable, disregard). Signature/5"~o~,~ ~q~.~ ~.~/~T /Z~C~~ : 6. Trend Analysis Summary and/or Quarterly Summary { Please attach: Annual Trend Analysis Summary for the 'last 12 periods for all tanks required to do Standard Inventory Control -. ~ ........~ ..... M0~pring (#UT-10); Quarterly Summaries for past year for tanks ..................... required t~--'d~'M°'~lfi~d- i~ent0~""co~tr0-1-M6~'~~'(~0T-'is) ............................................ 7. Meter Calibration Check Form ' Please attach current, completed Meter Calibration Check Form If required in permit conditions. 4,,_,ji.'A~' :.~_F~.. KEF~N C ',AIR POLLUTION CONTROL DISTR!q 2700 "~:' 8aRsrs'F":eld, CA. 9320'i PHASE I VAPOR RECOVERY, INSPECTION FORM ................ /S P/o " . ., ~ .... ,~.,,'~ ~.. ~' ' ''". · 1. P~CT'(UL, '~L:' P, or'R)' 2 T~K L~AT[~ REFER~CE 3 g~ OR N[~[N~ VA~R CAP , 4 B~K~ OR ~[NG FILL CAP 5. B~K~ C~ L~K ~ VA~R CAP 5. F[LL CA~ NOT P~PERLY 7. VA~R CA~ NOT P~PERLY S~ATED .")... 8. ~KET MISSING F~ FILL CAP ' 9. ¢~KET ~[SS[NG ¢~ VA~R CAP '0 FiLL ,I. OAPTOF: ?407 !i. VA~R ADAPTOR NOT T~T !2. ~SK~ B~E~ ADAPTOR & F{LL ~T~' i/ A~-- , . , ~BE MI~,,'~G iMPROPERLY S~,,, cD .... ;4. ~:CESS~VE VERTICAL PL.~Y :N !5. CO~.XZAL FILL ~BE SPRING McuH~,~M OEFECT D, tE I?. TUBE L-~.iGTH MDSLIREMSNT ~9, OTHER 20. CO~IMD'~TS: / -"HARNING : SYSTE~ MARKE[A ~tITH A CHECK ABOVE ARE IN VIOLATION OF KERN COUNTY AIR ,C>OLLUTICN .... ~,~;~-~--- -- CON ~ROL--~ DI'STR IC'T-- RtJ LEf-S-); ~209.;~.., a.-,l-2-. AND/OR -zt,-1.2..~ ....... TH E~.:-CAL:.IFO RNi,A-~HE,~ L-,TH-A-SAF ~¢-.CQDE ................ '~'~:*:~ SPECIFIES PENA~LT[,E,~ OF UP TO $!,000.00 PER DAY FOR EA~ V~OLAT[ON. TELEPHONE (805) ~-;' 8,~i-3582 C.(~C.-RNIN.= F~NA,_ RE~OLU,'.'.ON OF ;-HE IIOL~TION,~) ' ' ..~, KERN COU. N TY RESOURCE MANAGEMENT AGEi' ~' . ENVIRONMEN' HEALTH SERVICES DE,°ARTME~ ~'_ ~:-~-t'", 2700 "M" STR SUITE 300, BAKERSFIELD, ~.g~301 (805)881-363~ UNO~GROUN0 HAZARDOUS SUBSTANCE STORAG~ FACILITY ~ INSPECTION REPORT P~RMIT~ 150010C TiME IN TIME' OUT '~UMBER OF TANKS: 4 - . ." PERMIT POSTED? .., YES NO . ., .'.':' .:.' FACILITY.NAME:TRANSPORTATION K.H.S.D. · FACILITY ADDRESS: t600 8 STREET - · BAKERSFIELD, CA . OPERATORS NA~E=KERN HIGH SCHOOL 0ISTRICT ,. ~ - VIOLATIONS/OBSERVATIONS - · . b. Standard Inventory Control c. Mouified Inv~tory Cont¢o! d. In-tank Level Sensing Device :].-'::'. -,e, Groundwater Monitoring :, . ..,.,:. · . f. Vadose Zone Monitoring a. Liner b. Oouble~alled tank 1' c. Vault a. Pressurized b. Suction ~. OVErFiLL ~OTECTiON: 5. TIGHTNESS TES[NG 6. NEW CONSTRUCTION/MODZF!CAT[ON$ f 7. CLOSLJ~E/ASA~SCNMEN T ,.~. UNAUTHORIZE5 RELEASE MAINTENANCE, GENERAL SAFETY. AND 0PE~ATiNG CON01TION 0F FACiLiTY ~;'~ OMM EN TS/~ ECOMM EN , KERN COIL~TY RESOURCE ~I~NAGEMENT AG Et ~'-~'"~' ENVIRONMEN'11~HEALTH SERVICES DEPARTME 2700 "M" STREET, SUITE 300, BAKERSFIELD, CA.93301 .. (805)861-3636 UNDERGROUNDHAZARDOUS SUBSTANCE STORAGE FACILITY ~ INSPECTION REPORT ~ PERMIT~ TIME IN TIME OUT NUMBER OF TANK~: 4 PERMIT YES NO :T~P_E:.OE:,-tNSPE_CTI_ON: .... -.:_..~;-_.RO_~.I_.NE ............... -,- ..... REINSPECT_tON._:,: ................. COMPLAINT- .................. _::.:~::: FACILITY NAME:TRANSPORTATION K.H.S.D. FA C I L I TY AO D n ESS: ]..Eq.~ ...... ~_ ..... .~,T_~.~.~.~ ............................................................ BAKERSFIELD, CA OWNERS NAME:KERN HIGH SCHOOL DISTRICT ~-~Ta OPERATORS NA~E:KERN HIGH SCHOOL DISTRICT _ ~, - - ITEM VIOLATIONS/OBSERVATIONS 1. PRIMARY C0NTAINM~T MONITOR]NG: ' " a. Intercepting an dir~ting system b. Standard [nventopy Control c. Modified Inventory Control d, In-tank Level Sensing 0evice e. Groundwater Monitoring " f. Vadose Zone Monitoring 2.SECONDARY CONTAINMENT MONITORING: a. Liner b.. 0oub]e-~a]]ed tank c. Vault 3. PIPING MONITORING: a. Pressurized b. Suction c. Gravity 4. OVERFILL PROTECTION: 5. TIGHTNESS TESIflG 6. NEN CONSTRUCTION/MODIFICATIONS 7. CLOSURE/ABANDONMENT 8. UNAUTHORIZED RELEASE 9. MAINTENANCE, GENERAL SAFETY, AN0 OPERATING CONDITION OF FACILITY COMMENTS/RECOMMENDATIONS .................................................................................................................................... ~ .......... L ................... INSPECTOR:. ' /~. ~';>:'~..,:,.:.~...] REPORT RECE./ED BY- . · - ..¢:.,....-~ .......... : ........... ~.~ .....~.,~;,,~..,~ ............................ · ............................................................ , ..................... 6/29/90 FY 90 KERN HIGH SCHOOL DISTR~ 10:14:08 WTR02S1 FMS Purchase Orders t Ref: PUR.450 .11 Purchase Order: 1090 MO - Cl~d - Ship To: S12 V~dor 50045 MCNABB CONSTRUCTION COMPANY BAKERSFIELD SIGH SCHOOL 7808 OLCOTT AVE.. 1241 ~ STREET 'BAKERSFIELD CA BAKERSFIELD CA P/O Date: 1/11/90 Date Required: 0/00/00 Requisition: Reference: LLOYD MCCOY Account Code: 32.12.6112.72.7635.07 Last Update By: BROWN A/P Can Close: Y Receiving Required: N Draft Copy: N Hold Payments: N Amounts: Purchase Order Line Total: 14,250.00 (Blanket A~ount) Sales Tax: .0000 % .00 Purchase Order Total: 14,250.00 Total Paid To Date: 14,250.00 ~:~ Display Lines: Y 23-78 SA MW KS. IM II S1 S1018292 KB 6/29/90 FY 90 KERN HIGH SCHOOL DISTRI~ 10:15:14 WTR02$1 FMS Purchase Order Line L~ Ref: PUR.450L.01 Purchase Order: 1090 MO ~- P/O Total: 14250.00 "X"-Line 'Qty Ord Out Qty .Description Line Cost _ 1.000 .. REMOVE AND DIPOSE OF FUEL AND 2. 000 AS PER PROPOSAL. 3. 000 ' - 4. 000 NOT~: SEE PROPOSAL FOR FURTH 5. 000 INFORMATION. 6/29/90 FY 90 KERN HIGH SCHOO~ DISTRIi~ 10:20:40 WTR02Sl FMS ' Posted Invoice Look-Up t Ref: ACP. 460 . 11 Vendor: , 50045 Invoice: 9147 ~ Purchase Order: 1090 MO ~ ~2NABB CONSTRUCTION COMPANY Entered by: HANSEN Batch ID: 3H3 7808 OLCOTT AVE. ' Posted: 3/22/90 1099 Inv: Y BAKERSFIELD CA 93308 . Invoice Date: 3/09/90 Invoice Due Date: Voucher Number: 794 Other Reference: Invoice Description: MCNABB CONSTRUCTION COMPANY Account Number: 32.12.6112.72.7835.07 , Invoice Total: 12,825.00 !z' ::' ~;; :. i-: _..-"~.:=f' ~'_ ' - "--~i_L-'~_~. . ~ZL~_-. '" ,:; -" "- '~i ' f:;:::ZZ'l-C" ZZi.%~%=5.:~-i-L'c~:5}-f'231~ .~ia_C-" .';. ~ '; .... ~7-'-' '~ :-~z ~ :~ '~':7-ZC'"'-;L~ .iL. '_3Z: ~L~'-" .-i'. i'Z_'Z/~'r_~iL~Z--- ~.*. 'k "'--" '5 Paid Invoice Information: Check N~mber: APC~K 936373 Bank: FIB 112898210 Check Date: 3/23/90 Amount Paid: 12,825.00 Paid To: .3' MCNABB CONSTRUCTION COMPAR'Y 01-01 SA MW KS IM II S1 S1018292 KB BOARD OF TRUSTEES BAKERSFIELD, CAUFORNIA Brent P. Casper, President 93301-3899 David B. Stanton, Clerk Earle J. Gibbons, Vice President (805) 631-3100 Fred L. Starrh Kenne~ E. Secor THOMAS N. JONES, Ed.,D., Superintendent FAX: (805)32~-1209 Associate Superintendent, Business ENVIRONMENTAL HEALTH DEPARTMENT 2700 M Street - Suite 300 Bakersfield, CA 93301 RE: Fuel Tank Removal Kern High School District had fuel tanks removed from six locations: Foothill Permit # 110002C Highland Permit # 090009C Maintenance & Operations Permit # 060007C South Permit # 310009C Transportation Department Permit # 160010C West Permit # 280007C Enclosed are copies of paid invoices from McNabb Construction Company for your information. Thank you, Ben Seykora Director of Transportation AN AFFIRMATIVE ACTION/EQUAL OPPORTUNITY EMPLOYER ! jj~AII ~eters ~ust have 'calibration checks minimum of t~lce ~hich · a a year. nay ?~lnclude checks'idone bp the Department o] Weights and ~easures~ - ~. ~;~Beiore starttn~ calibration runs. wet the, calibration can with product 2~j return ~roduct? to 'storage. . , 3. ili Run 5 Eallons;~ with nozzle wide open into the can. Note gallons and .cUbic ~? inches drawn, ]and return product to 4. ?Run 5 RallonsJ~ with the nozzle one-half open' into th'~ can. Note gallons and ~}{ cubic inches drawn, and return product to storage. ' 5. ~After all product for one calibration check is returned to storage, remember ? to record the volume returned to storage In column 9 of the Inventor {'R ' Y ~j ecordini Sheet. . . 6. ~ If the volume measured, in a 5-gallon calibration can Is more than ~ cubic~ ? lnc~es above or below the 5-gallon mark, the meter requires calibration by a ~' registered de,ice rep~iraan. . Oate/Time[HO~ ~,k t/J' Fast'Flow J Siow Flow [Vo~'e Returned Calibration DeVice-Repairman Date of Pump t[P~oduct[ 5-Gallon Draft[ 5-Gallon Draft[ to StoraRe Required? Used for Calibration [" {hals}cu.'JlncheS[O ,lsJCu. lnCh~[ Gallons Yes-[' No Calibration ~. : j OWner or Operator Signature Calibrator's Signature ~t ~'-' _ Registration { ~ ~ . SUB~IT A COPY OF~ THI9 FORN ~ITll ANNUAL REPORT ~ ANNUAL TREND ANALYS I S ~lV[lV[ARY TANK ~ ~ TIME PERIOD: H~y ]987 to April 1988 QUARTER 1 TIME PERIOD: Mg¥ 1987 to J,,ly 1OR7 PERIOD 1: Total Minuses This Period (Line 3) ---Action 'Number' for' :~his Period (% in~.. .4:) .... 20.. PERIOD 2: Total Minuses This Period (Line 3) 20 Action Number for this Period (Line 4) 37 ~PERIOD 3: Total Minuses This Period (Line 3) 29 Action Number for this Period (Line 4) 54 QUARTER 2 TIME PERIOD: August 1987 to . ,October 1q87 . PERIOD 4: Total Minuses This,Period (Line 3) 40 Action Number for thiJ Period (Line 4) 69 ':' PERIOD 5: Total Minuses This Period (Line 3) 51 Action Number for this Period (Line 4) 85 PERIOD 6: Total Minuses This Period (Line 3) 61 Action Number for this Period (Line 4) 101 QUARTER 3 TIME PERIOD: PERIOD ?: Total Minuses This Period (Line 3) 68 i Action Number for this Period (Line 4) 117 PERIOD 8: Total Minuses This Period' (Line 3) 7~ Action Number for this Period (Line 4) 133 PERIOD 9: Total Minuses This Period (Line 3) 84 Action Number for this Period (Line 4) 149 QUARTER 4 TIME PERIOD: Febrt~?ry !9~8 tO ~ lO~ PERIOD IQ: Total Minuses This Period (Line 3) o/. , · Action Number for this Period (Line 4) ~5 PERIOD 11: Total Minuses This Period (Line 3) 108 Action Number for this Period (Line 4) 180 PERIOD 12: Total Minuses This Period (Line 3) 118 Action Number for this Period (Line 4) 196 I hereby certify this is a true and accurate report.. ANNUAL TREND ANALYSIS ~MMARY TIME PERIOD: M~¥ 1987 to April 1988 TANK g _ 2 - -- QUARTER 1 TIME PERIOD: May 1987 to 3u1¥ 1987 PERIOD 1: Total Minuses This Period (Line 3) 10 _Ac~i0n_Numbef::for:~his.:Period (~ine 4) 20 PERIOD 2: Total Minuses This Period (Line 3) Action Number for this Period (Line 4) _37 ,. 29 .pERIOD 3: Total Minuses This Period {Line 3) Action Number for this Period (.Line 4) . 54 QUARTER 2 TIME PERIOD: August 1987 to October 1987 PERIOD 4: Total Minuses This Period (Line ~) 41 Action Number for thi~ Period (Line 4) 69 PERIOD 5: Total Minuses This Period (Line ~) 51 Action Number for this Period (Line 4) ,85 61 PERIOD 6: Total Minuses This Period (Line ~) " ' Action Number for this Period (Line 4) 101 to January !98~ QUARTER 3 TIME PERIOD: _~tovcmbcr !97 -- PERIOD ~: Total Minuses This Period {Line S) 67 - Action Number for this Period (Line 4~ ~]7 PERIOD 8: Total Minuses This Period (Line 3) 7~ - Action Number for this Period (Line 4) PERIOD 9: Total Minuses This Perio~ (Line 3) 99 Action Number for this Period (Line 4) 149 .. to Aori! 1988 _ QUARTER 4 TIME PERIOD: February 1988 PERIOD 10: Total Minuses This Period (Line 8) 108 · Action Number for this Period (Line 4) 165 PERIOD 11: Total Minuses This Period (Line $) 118 Action Number for this Period (Line 4) 180 _. PERIOD 12: Total Minuses This Period (Line 3) 128 Action Number for this Period (Line 4) 196 I hereby certify this is a true and accurate report. · ' ~ Date : Signature ! ANNUAL TREND ANALYS I S MNIARY TANK # 1 TIME PERIOD: May !987 to a~ ~9~8 QUARTER I TIME PERIOD:· May 1987 to July 1987 PERIOD 1: Total Minuses This Period (Line 3) 1I ........................ Action .Number 'for this. Period-(Line PERIOD 2: Total Minuses This Period (Line 3) ,, Action Number for this Period (Line 4) 37 PERIOD 3: Total Minuses This Period (Line 3) 35 Action Number for this Period (Line 4) QUARTER 2 TIME PERIOD: A,,o,,~t lOS7 to Octnh~r ]OR7 PERIOD 4: Total Minuses This Period (Line 3) 48 Action Number for this Period (Line 4) PERIOD 5: Total Minuses This Period (Line 3) Action Number for this Period (Line 4) 85 PERIOD 6: Total Minuses This Period (Line 3) 69 Action Number for this Period (Line 4) 101 QUARTER 3 TIME PERIOD: November 1987 to January 1988 PERIOD ?: Total Minuses This Period (Line $) 82 Action Number for this Period (Line 4) 117 PERIOD 8: Total Minuses This Period (Line 3) 89 Action Number for this Period (Line 4) 133 PERIOD 9: Total Minuses This Period (Line 3) 87 Action Number for this Period (Line 4) 149 QUARTER 4 TIME PERIOD: b'~hr.nrv IQRR to ~nr~l PERIOD 10: Total Minuses This Period (Line 3) 95 Action Number for this Period (Line 4) PERIOD 11: Total Minuses This Period (Line 3) 103 Action Number for this Period (Line 4) 180 PERIOD 12: Total Minuses This Period (Line 3) 114 Action Number for this Period (Line 4) 196 I hereby certify this is a true and accur~'e-~'~'~'~-{. Facility TRANgPORTATTON DEPT. Permit = 16NO1NC .Month/Yr. 1. I have not done any major modifications to this facility during the last 12 months. .~ ,, . · _='-~ .... -Note.:--~All. major modifications requires Permit to ~onstruc'~' f~om 2., I have done major modifications for which I obtained Permit(s) to Construct from Permitting Authority Signature Permit to Construct # Date Attach a summary of all: -~ Routine and required maintenance done to this facility's tank, piping, and monitoring equipment. 10/7/87 -- Repair of submerged pumps or suction pumps. -- Replacement of flow-restricting leak detectors with same. fi- Repair/replacement of dispensers, meters, or nozzles. 7/31~87 - &/18/88 -- Repair of electronic leak detection components, or replacement with same. -- Ins'tallation of ball float valves. -- Installation or repair of vapor recovery/vent l'ines. Include the date of each repair or maintenance activity. NOTE: All repairs'or replacements in response to a leak require a Permit to Construct from the Permitting Authority as do all. other modifications to tanks, .piping or monitoring equipment not 'listed here. 4. Fuel Changes - Allowed for Motor Vehicle Fuel ~anks 0nly. List all fuel storage changes in tanks, noting: Date(s), tank number(s), new fuel(s) stored. NONE 5. Inventory control monitoring is required for this facility on the Permit to Operate, and I have no~ exceeded any reportable limits as listed in the appropriate inventory control monitoring handbook during the .last twelve months (if not/a~plicabl~ disregard). 'Signature //~~~-~*~--//~ 6. Trend Analysis S~ary Please attach Annual Trend Analysis Sua~ary for the last 12 periods. ...................... 7~. ...... Meter-Calibration Check For~ Please attach current.-~--~'-----------~-'~--~--~c°~ple'ted~eter'Calibrati°'ncheCk'~F°'~ 1700 Flower'Street KERN COUNTY HEALTH DEPARTMENT HEALTH OFRCER Bakersfield, California 93305 ,. Leon M Hebertson, M,D. Telephone (805) 861-3636 " ENVIRONMENTAl_ HEALTH DIVISION · DIRECTOR OF ENVIRONMENTAL HEALTH . Vernon S. Reichard INTERIM PERMIT ~ PERMIT~I 6OO10C · ISSUED: ~ JULY 1, 1986 'NOTE: ALL INTERIM REQUIREMENTS ESTABLISHED By THE PE~ITTING -. -' AUTHORITY MUST BE MET DURING THE TE~ 0F THIS PE~IT NON--TRANSFERABLE ** * POST ON PREMISES Kern County Health DepartmentO Permit Division of Environmental Health Application Date 1700 Flower Street, Bakersfield,~ CA 93305 No. of Tanks to be AbandOned; APPLICATION FOR PERMIT P~R TEMPORARY OR PERMAN]~F~ HAZARDOUS SUBSTANCES 'STOI~GE FACILIT~ ~Temporary Closure/Abandonment ~ ~- ~Pemanent C1D~ure/Ak~ndonment A. Project Contact Xlaame,_~rea code, phonej :. Days. ~~~ Ni~:s~ ,~~- " isis for ~il ~ ahd Gro~d~ter ~Pth ~inatio~ ~~~~~ ~rker s C~mn~tion 'Certffidation ~~'~6 _Insurer...~~~~~ ' Pro~s~ Starti~ ~te '~/i~/~ ' Pro~s~ C~plecion ~te ~rker's Cm~ation Certffidation } - Insurer D. Ch~ical Cm~sition of Materials Stor~ Tank' {. Chemical Stored (non-comercial name) Dates Stor~ Chemical Previously Stor~ ~ ~/ to to E. ~scri~ Meth~ for Retrievi~ S~ples .~~ ~~.~ ~. F. This application for: ~emoval or ~a~ndo~ent in place * * ~L~E ~IDE INFO~TION REQUESTED ~ ~E SIDE OF ~IS 'S~ B~O~ SU~I~I~ ~is fo~ has ~en c~plet~ under ~nalty of ~rjury and to the ~st of my ~owl~ge is true a~ corr~t. In~c~dd/e~All the Following Infomation: ~--~'Location of. Tank(s) , ~ & .~ ; ~Propose~ Sampling Locatio~ Indicati~ Approximate Dep~ ~/~f Samples ,, ~Nearest Street or Intersection ' ~y Water ~lls or Surface ~ters Within 100' R~ius of Facility / ~. ,..,~ ~ .. ,:. :..', .~ . ~:,. ~ ~ · , / c~q~ ~ ~~ ~,.~ Approved By/i Scale Kern County He Department ~' ,.. t Number A058 '~-?.~4~,~,~?~-.' t, 'Z ~ ame .'a nd "Ad d .:.High 'SchoOl 'Dist'ric~ ern ~Hi¢ }Street x,:~: .:i:..-. ? erm i t .~to '.Aba nd on ~e rm i'r es .,.., .... 'Ann" ' ' ' ~OST ON PRAISES '~".~. "Mt~ - ..... :' '.'?,, 2onditions as Follows i :~?:: X}?x':.:":?~t.. ' - 1 Permittee must' obtain permif from Fire 'Department ~ior 'i~}. '.. ': .~.. to' init'iating abandonment action.' '.'~q"?.j~::i'~?~:~[~? .:;. ' 2 Abandonment must be per approved methods ~' described in'<?'''':~g? ' permit application. 3. hll procoduros used ~ust be ~n a~eordanc~ wigh '. ,': .. :. .: :.-t~- ,~.~,: : 'requirements of .Standards and Guidelines developed for . _,:~:~ 'j .-~> ~. .... . implementation of Kern County Ordinance Code ~3941. A copy of these requirements are enclosed with this permit. .._. · 4. A minimum of two samples at depths of' approximately 2' '' h',./~':'~<~?~:-~': and 6' directl~ under the center of the tank must lbo · -.';"' retrieved and sampled for oil an0 grease extraction, and lead ' ' ~ 5. Adviso this office of time and dat~ of proposed sampling '~:4::~:/ LABORATORIES PETflOLEU¥ ~dAIN OFFIGE: 4100 PIERGE ROAD, BAKERSFIELD, GA. g3308 PHONE 327-4911 RLW Equipment Date Reported: 7/23/85 2080 South Union~Avenue Date Received:-7/18/85 --:~--.~-~-:TBakersfield,~California..9330~ ........ ~'":r..:::-;~:'-----/:--~-.-:~--~:-:-~-~-~Iiaboratory NO..:: 11970,-119ll.-~.~-~-. Attention Mr. Brian McNab' P.O. #23955 #1 - Kern High School Bus Garage 1600 B St. 1:30 PM Existing Waste Oil Tank-2' #2 - Kern High .School Bus Garage '1600 B St. 1:30 PM Existing Waste Oil Tank-6' Constituents #1 #2 Oil & Grease* 0.15 0.06% Total Lead 8.0 pPm AR (-) 1.00 ppm AR * Determined by Freon Extraction. ppm - parts per million AR- as received (-) refers to "less than". B C LABORATORIES, INC. J~ J. EGLIN, REG. CHEM. ENGII. PETIIOL£U¥ MAIN OFFICE: 4100 PIERCE ROAD, BAKERSFIELD, CA. 93308 PHONE 327-4911 RLW Equipment ...... ~ ...... ~ ............ pat~ ~R.epor~gd: ~?/23/85 ~080 SOuth'Uni0n 'Avenue: ..... ~ ~'~ :';'~ '-- ' ..... Date Received:-7/18/85'-~-'-:~'~'' .... ~ Bakersfield, California 93307 Laboratory No.: 11970, 11971 Attention Mr. Brian McNab P.O. ~23955 Sample Descriptions.: #1~- Kern High School Bus Garage 1600 B St. 1:30 PM Existing Waste Oil Tank-2' #2 - Kern High School Bus Garage 1600 B St. 1:30 PM Existing. Waste Oil Tank-6' Constituents #1 #2 Oil & Grease* 0.15 0.06% Total Lead 8.0 ppm AR (-) 1.00 ppm AR * Determined by Freon Extraction. ppm - parts per million AR- as received '(-) refers to "less than". B C LABORATORIES, INC. LABORATORIES J. J, EGLIN, Ill:G, CHl:M. ENGII. PETI~OLEUJl MAIN OFFICE: 4100 PIERCE ROAD, BAKERSFIELD, CA. 9334]8 PHONE 327-4911 RLW Equipment Date Reported: 7/23/85 -"-'-':t~--":~"-r2080 South~Union-Avenue ---::;~:~.:.-':r~:.~-~-~-~._:_.....j:..~-~;_u_:~.~. :.. .u'.~.Date Received: ...~/I8/85 Bakersfield, California 93307 Laboratory No.: 11970, Attention Mr. Brian McNab P.O. #23955 ~.am~le Descriptions: #1 - Kern High School Bus Garage 1600 B St. 1:30 PM Existing Waste Oil Tank-2' ~2 - Kern High School Bus Garage 1600 B St. 1:30 PM Existing Waste Oil Tank-6' Constituents #1 #2 Oil & Grease* 0.15 0.06% Total Lead 8.0 ppm AR (-) 1.00 ppm AR * Determined by Freon Extraction. ppm - parts per million AR- as received (-) refers to "less than". B C LABORATORIES, INC. '~700FIo~,ermreet RN COUNTY HEALTH DEPART T HEALTH OFFICER B&keralleid, Cali/ornia 93305 " Leon M Hebertson, M.D. Telephone (805) 86t-3636 ENVIRONMENTAL HEALTH DIVISION ,~r~.~,/.~_~t DIRECTOR OF ENVIRONMENTAL HEALTH ////*~~}.: Vernon S. Reichard August 8, 1985 RLW Equipment _ , 2080 South Union Avenue Bakersfield, California 93307 Dear Mr. McNabb: This is to advise you that.this department has.reviewed the project results for the fuel seepage investigation you conducted at the Kern High School Bus Garge, 1600 "B' Street, Bakersfield, California. Based upon the findings described in the report, this department is satisfied that the assessment is'complete and no significant soil contamina- tion resulting from fuel tank leakage exists at the site. Thank you for your cooperation in this matter. Sincerely, 'Environmental Health Specialist II Hazardous Substances. Management Program AB:aa DISTRICT OFFICES Delano . Lamonl . Lake Isabella . Molave . Rtdgecre,,! . Shatter . Taft