Loading...
HomeMy WebLinkAboutABOVEGROUND TANK FILE #1 Mail a copy of the completed form to; CUPA Inspector: -~,c~ ~)~S California Regional Water Quali~ Consol Board Address: ~ Date: ~ / 2~ / The following facility is storing "petroleum" in a single storage tank greater than 660 gallons or in multiple storage tanks with a cumulative storage capacity greater than 1,320 gallons. "Petroleum" means crude oil, or any fraction thereof, which is liquid at 60 degrees Fahrenheit temperature and 14.7 pounds per square inch absolute pressure. This includes petroleum based substances comprised of a complex blend of hydrocarbons, such as gasoline, diesel, jet fuels, residual fuel oils, lubricants, some petroleum solvents, and used oils. An example of a substance that is not "petroleum" is liquid propane gas (LPG). Note: The backside of this form identifies storage tanks and facilities exempt from the state Aboveground Petroleum Storage Act SPCC requirement. Facility Name: Facility Address: t6 20 Contact: ~r~,c.. poa-cea. Phone: ( ~fo( ) ~Z~ - 7073 [ ~ The Facili~is::in~Omplidn~e:'with~:H&SE SectiOh 25270:5(c)~ the prepa~ation of'an':SPCCplan: Ac0mplete copy of. the::facilit~'s SPCC plan, certified bYa Re~gteredProfes'sionaI~Engin~e(,is maintained at the facBi~, w~ch is' normally attended aLleast 8 hours per day~ I[:.the :facility' is not attended at least 8 hoursper day, the SPCC planis maintained:at :the :nearest field'S'office. [ Thefaci!i~is'not. in compliancewithH&SCSe~tiOn 25270.5(c). Thi~ form :constitutes a rqfe~ral to:the Regional Board for correction ofthe following violation; I:~ Thefaeility dbes not haVea:certified SPCC planin place. :~ + The;o~ner 0r 0~e~aior ~was unaware:of the AbO~egr0und Petrol6um Storage A~t;:: A copy of the ~ ~ta~e:;Wat~r~R~S6urc~S COntroiBoard,::Xbo~egr°und ~ank~Prog~hmbrOchur~:Whs or~via~d~to:~:' .. :. the~o~e~:o~ 0peratoE. cc: Carol Julian State Water Resources Control Board Division of Clean Water Programs P.O. Box 944212 Sacramento, CA 94244-2120 SWRCB. CWP Form AGT-I (06/28/99) ABOVEGROUND PETROLEUM STORAGE TANK PROGRAM STORAGE TANKS AND FACILITIES EXEMPT FROM THE STATE SPCC REQUIREMENT The Aboveground Petroleum Storage Act (APSA), Health and Safety Code (H&SC), Section 25270.2(k), defines "storage tank" as any aboveground tank or container used for the storage of petroleum. "Storage tank" does not include any of the following: ~1. 1) A vessel boiler which is subject to Part 6 of Division 5 of the Labor Code. ( pressure or [] A tank hazardous defined in subdivision of Section (2) storage containing waste, as (g) 25316, if the person owning or operating the storage tank has been issued a hazardous waste facilities permit for the storage tank by the Department of Toxic Substances Control.  An oil tank which is to Section 3106 of the Public (3) aboveground production subject Resources Code (Division of Oil and Gas). ['~ Oil-filled electrical including, but not limited transformers, circuit equipment, to, breakers, or capacitors, if the oil-filled electrical equipment meets either of the following conditions: (A) The equipment contains less than 10,000 gallons of dielectric fluid, or (B) The equipment contains 10,000 gallons or more of dielectric fluid with PCB levels less than 50 ppm. The appropriate containment or diversionary structures or equipment are employed to prevent discharged oil from reaching a navigable water course, and the electrical equipment is visually inspected in accordance with the usual routine maintenance procedures of the owner or operator. If you checked any one of the four boxes above, then the facility is not subject to the state APSA registration, fee or SPCC plan requirements. Additionally, H&SC Sect/on 25270.5(d) specifically does not require an SPCC plan for the following facilities: Farms, nurseries, and logging or construction sites, which do not have a single tank exceeding 20,000 gallons and which have a cumulative storage capacity no greater than 100,000 gallons. However, these facilities are still required to pay a fee and register their tank(s) with the State Water Resources Control Board. CoORRECTION ~OTICE ~ BAKERSFIELD FIRE'DEPARTMENT N° 97 8 5',d'/za~ ~~ Loeation/(O'ZO ~".. ~"gd~~ Sub Div ..... Blk. . Lot . .,,~.,.-.'v'~ .. "~. ::,,:.::~: You are hereby required to make the following corrections ., Completion ~ate for Co~ec~ons lnsp~tor BAKERSFIELD FIRE DEPARTMENT May 18, 1998 Doug Jenkins Sierra Iron & Metal Company FI~ c,i~F P.O. Box 1340 MICHAEL R. KELLY Bakersfield, CA 93302 ADMINISTg. ATIVE SEI~VICES 2101 'H' Slmot RE: One (1) 2,200 Gallon Above Ground Diesel Tank Located at 1620 E. Brundage Bake~fleld, CA 93301 Lane in Bakersfield. (805) 326-3941 FAX (805) 3954349 Dear Mr. Jenkins: SUPPRESSION SEI~VICES 2101 'H' Street An inspection was performed at the above referenced address on May 14, 1998. Bakersfield, CA 93301 (805) 326-3941 The purpose of this inspection was to: FAX (805) 395-1349 1. Verify the existence of one (1) 2,200 gallon diesel tank. PI~'VENTION SEll'VICES 2. Confirm that it meets the Uniform Fire Code. 1715 Chester Ave, Bake~eld, CA 93,301 3. Confirm how long it has been in operation. (805) 326-3951 FAX (805) 326-0576 The documentation you provided indicates that your tank has been at your ENVIRONMENI'AL SERVICES facility, and in operation, for at least 9 yeats. Therefore, your tank status is considered 1715 Chester Ave, "Existing Non-Conformance" meaning, that as long as the tank is in continual use, it is Bakersfield, CA 93301 exempt from current regulatory requirements. It must be clear, that any modification to (805) 326-3979 FAX (805)3260576 the tank or temporary closure of the tank (for more than 90 days), will void your exempt status and require replacement. IIL~INING DIVISION 5642 Victor Street As per our conversation, the following items must be done: Bokersfleld, CA 93,3~ (805) 399-4697 FAX (805)399-5763 1. Add fuel quantity to business plan. 2. Properly ground tank. 3. Properly placard tank. 4. Provide protective barriers around tank. Should you need any further assistance, please feel free to call me at 326-3979. Sincerely, Steve Underwood Underground Storage Tank Inspector SBU/dm cc: Enclosures In conformity with provisions of pertinent ordinances, codes and/or regulations, application is rnade by: - 'Name of Company ) ' ' ' " " Address to display, store, install, use, operate, sell or handle materials or processes involving or creating con- ditions deemed hazardous to I'ife or property as follows: ~~ .... ~l~.A ......................... ~ ........... .~~. ..................................... z ..............