HomeMy WebLinkAboutUNDERGROUND TANK FILE #3ltJ f= Owner Statements of Designated Underground Storage Tank (UST) Operator ` and Understanding of and Compliance with UST Requirements Facility Name: Wholesale Fuels Company Facility ID #: 3393 Facility Address: 2200 E. Brundage Lane, Bakersfield, CA 93307 (City) Reason for Submitting this Form (Check One) ^ Change of Designated Operator Facility Phone #: 661-327-4900 X Update Certificate Expiration Date Designated UST Operator(s) for this Facility PRIMARY Designated Operator's Name: Douglas M. Young III Relation to UST Facility (Check One) Business Name (If different from above): Confidence UST Services, Inc. ^ Owner ^ Operator ^ Employee Designated Operator's Phone #: 800-339-9930 ^ Service Technician x Third-Party International Code Council Certification #: 0878646-UC Expiration Date: September 22, 2008 ALTERNATE 1 (Optional) Designated Operator's Name: Jennifer Davis Relation to UST Facility (Check One) Business Name (If different from above): Confidence UST Services, Inc. ^ Owner ^ Operator ^ Employee Designated Operator's Phone #: 800-339-9930 ^ Service Technician x Third-Party International Code Council Certification #: 5252886-UC Expiration Date: March 15, 2009 ALTERNATE 2 (Optional) Designated Operator's Name: Edward Mitchell Relation to UST Facility (Check One) Business Name (If different from above): Confidence UST Services, Inc. ^ Owner ^ Operator ^ Employee Designated Operator's Phone #: 800-339-9930 ^ Service Technician x Third-Party International Code Council Certification #: 5258845-UC Expiration Date: Mah 15, 2008 I certify that, for the facility indicated at the top of this page, the individual(s) listed above will serve as Designated UST Operator(s). The individual(s) will conduct and document monthly facility inspections and annual facility employee training, in accordance with California Code of Regulations, title 23, section 2715(c) - (f). Furthermore, I understand and am in compliance with the requirements (statutes, regulations, and local ordinances) applicable to underground storage tanks. NAME OF TANK OWNER (Please Print): 1~ h y j_c S ~= ~ +~ I^ U ~ _~.:5 C V rn SIGNATURE OF TANK OWNER: DATE: OWNER'S PHONE #: 661-327-4900 NOTE: 1) SUBMIT THIS COMPLETED FORM TO THE LOCAL AGENCY (NOT THE STATE WATER RESOURCES CONTROL BOARD) BY JANUARY 1, 2005. THE LOCAL AGENCY LIST IS AVAILABLE AT: www.waterboards.ca..p_ov/ust/contacts/cu~a a~ys.html. 2) NOTIFY THE LOCAL AGENCY OF ANY CHANGES TO THIS INFORMATION WITHIN 30 DAYS OF THE CHANGE. November 2004 ^~ ..~' ~0 ~ Owner Statements of Designated Underground Storage Tank (UST) Operator and Understanding of and Compliance with UST Requirements Facility Name: Wholesale Fuels Company Facility ID #: 3393 Facility Address: 2200 E. Brundage Lane, Bakersfield, CA 93307 (City) Reason for Submitting this Form (Check One) X Addition of Designated Operator Facility Phone #: 661-327-4900 ^ Update Certificate Expiration Date Designated UST Operator(s) for this Facility ALTERNATE 3 (Optional) Designated Operator's Name: Jessica L. Meyers Relation to UST Facility (Check One) Business Name (If different from above): Confidence UST Services, Inc. ^ Owner ^ Operator ^ Employee Designated Operator's Phone #: 800-339-9930 ^ Service Technician x Third-Party International Code Council Certification #: 5313857-UC Expiration Date: June 30, 2009 ALTERNATE 4 (Optional) Designated Operator's Name: Relation to UST Facility (Check One) Business Name (If different from above): ^ Owner ^ Operator ^ Employee Designated Operator's Phone #: ^ Service Technician ^ Third-Party International Code Council Certification #: Expiration Date: ALTERNATE 5 (Optional) Designated Operator's Name: Relation to UST Facility (Check One) Business Name (If different from above): ^ Owner ^ Operator ^ Employee Designated Operator's Phone #: ^ Service Technician ^ Third-Party International Code Council Certification #: Expiration Date: I certify that, for the facility indicated at the top of this page, the individual(s) listed above will serve as Designated UST Operator(s). The individual(s) will conduct and document monthly facility inspections and annual, facility employee training, in accordance with California Code of Regulations, title 23, section 2715(c) - (f). Furthermore, I understand and am in compliance with the requirements (statutes, regulations, and local ordinances) applicable to underground storage tanks. NAME OF TANK OWNER (Please Print): Charles McCan SIGNATURE OF TANK OWNER: DATE: August 9, 2007 OWNER'S PHONE #: 661-327-4900 NOTE: I) SUBMIT THIS COMPLETED FORM TO THE LOCAL AGENCY (NOT THE STATE WATER RESOURCES CONTROL BOARD) BY JANUARY 1, 2005. THE LOCAL AGENCY LIST IS AVAILABLE AT: www.waterboards.ca.eov/ust/contacts/cu~a ag_ sy htm1. 2) NOTIFY THE LOCAL AGENCY OF ANY CHANGES TO THIS INFORMATION WITHIN 30 DAYS OF THE CHANGE. November 2004 GU ~ Owner Statements of Designated Underground Storage Tank (UST) Operator and Understanding of and Compliance with UST Requirements Facility Name: Wholesale Fuels Company Facility ID #: 3393 Facility Address: 2200 E. Brundage Lane, Bakersfield, CA 93307 (City) Reason for Submitting this Form (Check One) ^ Change of Designated Operator Facility Phone #: 661-327-4900 X Update Certificate Expiration Date Designated UST Oaerator(s1 for this Facility ~~~~~ Designated Operator's Name: Douglas M. Young III Relation to UST Facility (Check One) Business Name (If difj"erent from above): Cor~rdence UST Services, Inc. ^ Owner O Operator ^ Employee Designated Operator's Phone #: 800.339-9930 ^ Service Technician x Third-Party International Code Council Certification #: 0878646-UC Expiration Date: September 22, 2008 Designated Operator's Name: Jennifer Davis Relation to UST Facility (Check One) Business Name (If di,~erent from above): Co~dence UST Services, Inc. ^ Owner ^ Operator ^ Employee Designated Operator's Phone #: 800-339-9930 ^ Service Te~nician x Third-Party International Code Council Certification #: 5252886-UC Expiration Date: March 15, 2009 ALTERNATE 1 oral ALTERNATE 2 (Optional) Designated Operator's Name: Edward Mitchell Relation to UST Facility (Check One) Business Name (If di,~`erent from above): Conf dente UST Services, Inc. ^ Owner ^ Operator ^ Employce Designated Operator's Phone #: 800-339-9930 ^ Service Technician x Third-Party International Code Council Certification #: 5258845-UC Expiration Date: Mah 15, 2008 I certify that, for the facility indicated at the top of this page, the individual(s) listed above will serve as Designated UST Operator(s). The individual(s) will conduct and document monthly facility inspections and annual facility employee training, in accordance with California Code of Regulations, title 23, section 2715(c) - (f). Furthermore, i understand and am in compliance with the requirements (statutes, regulations, and local ordinances) applicable to underground storage tanks. NAME OF TANK OWNER (Please Print): ~ ~ v j c s a SIGNATURE OF TANK OWNER: DATE: OWNER'S PHONE #: 661-327-4900 NOTE: 1) SUBMIT THIS COMPLETED FORM TO THE LOCAL AGENCY (NOT THE STATE WATER RESOURCES CONTROL BOARD) BY JANUARY 1, 2005. THE LOCAL AGENCY LIST IS AVAILABLE AT: www.waterboards.ca.gov/ust/contacts/cupa a~ys.html. 2) NOTIFY THE LOCAL AGENCY OF ANY CHANGES TO THIS INFORMATION WITHIN 30 DAYS OF THE CHANGE. November 2004 JtatJ-26-2065 15:25 From:JACO OIL 6613933928 To:661 631 3872 P.2~2 l - OWNER STATEMENTS OF Bakersfield Fire Dept. ~S_ ~ p Envytro)nmental Service ANO uNDERS-TANE?ING OF AND Ct>~APLIANCE VVffl'N ~ ` "`' ' 9th Tt-u~uo Ave.. St+e. 210 t~ REQUIREMEI-tT~ ~ Bakersfield. GA 93301 Tel: (861)328-3979 Pepe ~ or ~ Fax.: (661j 852-2171 FAC1l1TY NINNE: ~~~ LE.}t3 Lr~ ,i~u E~ ,S C a ..~+. FAC11_m is • a„~C~~ __ ~ _r. _ , FAq(J11/ AGGRESS Reseal !or Stlbndfan0 ttrs FotttR (Gflodt otro) . _.~~C~(J ~..BkLJ/VUECT~ LR~N~~ o cr~u,eootoos~te~tooe~ator FApIITY PHONE Nt).: L^ I - 3.R '7- LSO ~._. _ ~ __ _.. _. ~ Update Cottification Expuatlao Deb DESICTIA'TED UST OPERATOR(S) FOR THi3 FAC111TY PRIMARY Dael~ad Oper~e Nmno DdvG M . FyavN G~1 Business Nsme In dilfere/N hom x L~ONF'tta~tVC6 [!3T 5ERt1iCE5.tnrC Deei~d OparalortrPhon9lr ~~~ "3.', ~- Q~D ~nW00nN C0lID COuntll Corot st D877~. ~a ~f~ - l~ ~ ALT4-RNATE 4 (ta060Aef) o 0peretorc Nemo: 3~rn~~e_x pcw ~s 6YSlhoss Nano fIr dtll~rlo/X Rorn a0ore). Deaipnol0d OPOr~tor`t Phone M Wv ' ~,~G~ ^~ G~ ~ ~ bpontseate! t.odo t.ounN_CerlfiCetion t ~~, ~~ (.Q _ l~ auERNAXE 2 ~ Oesiprwied Oper.Moe'i Name: et,an.e. Nam. ~+faMe~..K ~~n.~ Destgneted OpY-6tot'e Phonne Mt i~-~~G-~,l l v../fir -~vw. _ -33 ~- 30 Ralston tp tJST FedikY (Check one) n Owner D Oporalor o riltprt-yee O Sdbito ToChnir~en ~ Th'vd PeAy Expimt~ axle Reletlen b U5T Fatipltr_ (Chet3 one) tl Owne- O Opsrabr d EmplWee O SorNOO Ted ~TMrd Party E^v~eua-oete. 3 / ta. ! rJ1 Rsi~lon b UST Fa~Rtr. (CtwcJr aw) v owr,e. v opsrMor n Emproyas 4 Sarvbe Tadtildan 4tj TNrd Party fn4arnalfam! Coda Camel! co~uenuor, rt ~a.~, d g s -c.Q-Gi w _ _ 4 _ Fxpfiatlonoab Jr~/~ Q ~__ _..__ .. _ _ ___. _ KQTir TN@ IOCAL RE6UUlTORY AGF.NCI: MUST 8E NtTTIFIEO OF ANY CHANGES T4 THIS INFORMATION WCiHIN 30 GAYS t7F THE CHANGE. i oertif)r that, for the facilRy indicated at the top of this page. the individual{s) listed apove will serve as Designated UST tJperator(s). The individual(s) will conduct and document monthly fadllty inspections and annum faculty en'tpioy~ training, is accordance with CaUfomia Code of Regulations, title 23, section 715(c~ - (f). furthermore,l understand and am jn compliance with the requirements (statutes, regulations, and local ord~ances} applicable to underground storage tanks. NAME t3F TMpC OWMER ' OR oNM>:R's AGENT (Ploaso PAnt)~ r'. NN ~ L E.~ !r1 F e ~ n1 s(GNATURt~ OF 7ANIf OWNER _ OR OWNER'S AGENT (PIt3HS0 Flint}: ~ G.,.~a.- ~ ~ ~~ L f ~-~ ~~ cf Etl~ ~ u : E, I F ~~: DATE: /~~G~~Y' OWNER'S PHONE fl: ti+fr/- ~ t/~-~'7e3A.'~ ..__.__ FD2104 ~~ UNIFIED PROGRAM INSPECTION CHECKLIST SECTION 1: Business Plan and Inventory Program ~,. BAKERSFIELD FIRE DEPT Prevention Services ~~~~ 900 Truxtun Ave., Suite 210 AR7-O s gakers8eld, CA 93301 Tel.: (661) 326-3979 Fax: (661) 872-2171 FACILITY NAME NSPECTION DATE INSPECTION TIME ADDRESS HONE NO. O OF EMPLOYEES t~ FACILITY CONTACT USINESS ID NUMBER 15-021- Section 1: Business Plan and Inventory Program ROUTINE ^ COMBINED ^ JOINT AGENCY ^ MULTI-AGENCY ^ COMPLAINT ^ RE-INSPECTION C V (c=Compliance OPERATION V=Violation COMMENTS ^ ^ APPROPRIATE PERMIT ON HAND ^ ^ BUSItI@SS PLAN CONTACT INFORMATION ACCURATE ^ ^ VISIBLE ADDRESS ^ ^ CORRECT OCCUPANCY ^ ^ VERIFICATION OF INVENTORY MATERIALS ^ ^ VERIFICATION OF QUANTITIES ^ ^ VERIFICATION OF LOCATION ^ ^ PROPER SEGREGATION OF MATERIAL ^ ^ VERIFICATION OF MSDS AVAILABILITY ^ ^ VERIFICATION OF HAZ MAT TRAINING ^ ^ VERIFICATION OF ABATEMENT SUPPLIES AND PROCEDURES ^ ^ EMERGENCY PROCEDURES ADEQUATE ^ ^ CONTAINERS PROPERLY LABELED ^ ^ HOUSEKEEPING ^ ^ FIRE PROTECTION ^ ^ SITE DIAGRAM ADEQUATE & ON HAND ANY HAZARDOUS WASTE ON SITE? ^ YES ^ NO '~ ~ ~~st,f-D~ .[/ :6'~ ~ll S r S cQ!/~ ~' ~~YI~~ ~/Ui,21 ~Il~ !gr~('~C~G~ QUESTIONS REG~NG THISIS I~TION? PLEASE CALL US AT (661) 320-3 9 In pector (Please Print) Fire Prevention / 1" In / Shift of Site/Station # Business Site/School Site Responsible Party (Please Prat) White -Prevention Services Yellow -Station Copy Pink -Business Copy FD2048 (Rev. 02!05) i~ UNDERGROUND STORAGE TANKS BAKERSFIELD FIRE DEPT. • B BR9P1 D _. _,_ -. - . _ FIR! Prevention Services APPLICATION -Trrv ~Ai!~ ~ BakersT fie dnCA 93301 210 TO PERFORM ELD /LINE TESTING ~ Tel.: (661) 326-3979 1 S6989 SECONDARY CONTAINMENT TESTING Fax: (661) 852-2171 /TANK TIGHTNESS TEST AND TO PERFORM FUEL MONITORING CERTIFICATION Page 1 of 1 PERMIT NO. ~/ ~O~ - `~ ENHANCED LEAK DETECTION /~ UNE TESTING -r ^'. SB-9B9 SECONDARY CONTAINMENT TESTING ' wNKTIGHTNESSTEST l PS/ TO PERFORM FUEL MONRORWG CERTIFICATION SITE INFORMATION FACILITY n NAftSE S PHONE NUft76ER OF CONTACT PERSON t,z -100 ADDRESS k ~~ OWNERS NAME OPERATORS NAR9E _ - -" PERFAIT TO.OPERATE NO.` ~'"~""~ - _" NUMBER OF TANKS TO BE TESTED IS PIPING GOING TO BE TESTED? .~ YES ,~ NO TANK# VOLUME CONTENTS TANK TESTING COMPANY NA E OF TESTING COMPANY NA E 8 PHONE NUI8IBER OF CONT CT PERSON 1 MAILING A D ESS S 1 ~1 ' ~ O NAME & PHONE NUMBER F TESTER OR s PECIA 1n INSPECTOR 0 - CERTIFICATION #: 0 TE & TIME EST TO BE CONDUCTED 0 ICC #: ~2 lv ° tT- TEST METHOD SIG TORE OF APPLICAN DATE /\ v --~ --- - - H A L ION DOMES A HERMIT - H N -ARF~ROVED .._ APPROVED BY DATE Y ~ FD 2095 (Rev. 09105) ~~~~- -- MONITORING SYSTEM (CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited.• Chapter 6. ~ Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations Tliis form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the wark. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of this date. A. General Information Facility Name: #1001 Wholesale Fuels, Inc. Site Address: 2200 East Brundage Lane City: Bakersfield Facility Contact Person: Omero Garcia Make/Model of Monitoring System: Veeder-Root TLS-350 B. Inventory of Equipment Tested/Certified Bldg. No.: Zip: 93307 Contact Phone No.: 661-393-7000 Date of Testing/Servicing: 9/14/2007 Tank ID: T-1 LS Clear 10000 gallons [X] In-Tank Gauging Probe. Model:8a739o-107 ^ Annular Space or Vault Probe. Model: ^ Piping Sump /Trench Sensor(s). Model: ^ Fill Sump Sensor(s) Model: ^ Mechanical Line Leak Detector. Model: L] Electronic Line Leak Detector. Model: tempo-Miller U Tank Overfill /High Level Sensor. Model:8a73so-107 ^ Other (specify equip. type and model in Sec. E on Pg. 2) Tank ID: T-3,Clear Diesel 20000 gallons [x] In-Tank Gauging Probe. Mode1:847390-107 ^ Annular Space or Vault Sensor. Model: ^ Piping Sump /Trench Sensor(s). Model: ^ Fill Sump Sensors(s). Model: ^ Mechanical Line Leak Detector. Model: [X] Electronic Line Leak Detector. Model:Campo-Miller L] Tank Overfill /High Level Sensor. Model:8a7390-107 ^ Other (specify equip. type and model in Sec. E on Pg. 2) Dispenser ID: T-1 Clear [x] Dispenser Containment Sensor(s). Model: 794380-208 [X] Shear Valve(s). ^ Dispenser Containment Float(s) and Chain(s). Dispenser ID: T-3 Clear Diesel U Dispenser Containment Sensor(s). Model: 79x380-208 U Shear Valve(s). ^ Dispenser Containment Float(s) and Chains(s). Dispenser ID: T-5 Dyed [X] Dispenser Containment Sensor(s). Model: 79x380-208 U Shear Valve(s). ^ Dispenser Containment Float(s) and Chain(s) contains more tanks or dispensers, copy this form. Tank ID• T-2 L-S Dyed 10000 gallons [x] In-Tank Gauging Probe. Model: 847390-107 ^ Annular Space or Vault Sensor. Model: ^ Piping Sump /Trench Sensor(s). Model: ^ Fill Sump Sensor(s). Model: ^ Mechanical Line Leak Detector. Model: U Electronic Line Leak Detector. Model: Campo-Miller U Tank Overfill /High Leval Sensor. Model: ~~390-107 ^ Other (specify equip. type and model in Sec. E on Pg. 2) Tank ID: T-4 Unleaded 20000 gallons [x] In-Tank Gauging Probe. Model: ~~390-107 ^ Annular Space or Vault Sensor. Model: ^ Piping Sump /Trench Sensor(s). Model: ^ Fill Sump Sensor(s). Model: ^ Mechanical Line Leak Detector. Model: ~x] Electronic Line Leak Detector. Model: Campo-Miller ~x] Tank Overfill /High Level Sensor. Model: 847390-107 ^ Other (specify equip. typs and model in Sec. E on Pg. 2) Dispenser ID: T-2 LS Clear (X] Dispenser Containment Sensor(s). Model: 79x380-208 [X] Shear Valve(s). ^ Dispenser Containment Float(s) and Chain(s) Dispenser ID: T-4 Unleaded U Dispenser Containment Sensor(s). Model: 79x380-208 [X] Shear Valve(s). ^ Dispenser Containment Float(s) and Chain(s). Dispenser ID: T-6 EPA Diesel ' [x] Dispenser Containment Sensor(s). Model: 794380-208 U Shear Valve(s). , ^ Dispenser Containment Float(s) and Chain(s). every tank and dispenser at C. CertifiCatioII - I certify that the equipment identified in this document was inspected/services in accordance with the manufacturers' guidlines. Attached to this Certification is information (eg. manufacturers' checklist) neoes~ry to verify that this information is ~rrect and a plot plan showing the layout of monitoring equipment. For equipment capable of generating such reports, I have attached a rnpy of the report; (check all that apply) x^ System Set-up [~ Alarm history report Technician Name (print): Kristopher Icarus Signature: ,~,/_~,~ ~~~ Certification No: B3a1os License No: soa9oa Testing- Company Name: Confidence uST Services, inc. Phone No: 80039-9930 Site Address: 2200 East Brundage Lane ,Bakersfield, CA 93307 Date Of Testing/Servicing: 9/14/2007 MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited.• Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring_system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of this date. A. General Information Facility Name: #1001 Wholesale Fuels, Inc. Site Address: 2200 East Brundaoe Lane Facility Contact Person: Omero Garcia Make/Model of Monitoring System: Veeder-Root TLS-350 B. Inventory of E uipment Tested/CertiSed c~ w~ o~ noza en ape.,fic «~~ ~pated/aerviced: Tank ID: T-5 LS dyed 20000 gallons [X] In-Tank Gauging Probe. Model:s4739o-io7 ^ Annular Space or Vault Probe. Model: ^ Piping Sump /Trench Sensor(s). Model: ^ Fill Sump Sensor(s) Model: ^ Mechanical Line Leak Detector. Model: [X] Electronic Line Leak Detector. Model: tempo-AAiller U Tank Overfill /High Level Sensor. Model:847390-107 ^ Other (specify equip. type and model in Sec. E on Pg. 2) Tank ID: T-7 L-S Dyed 20000 gallons U In-Tank Gauging Probe. Mode1:847390-107 ^ Annular Space or Vault Sensor. Model: ^ Piping Sump /Trench Sensor(s). Model: ^ Fill Sump Sensors(s). Model: ^ Mechanical Line Leak Decector. Model: U Electronic Line Leak Detector. Model:Campo-Iwiller U Tank Overfill /High Level Sensor. Model:84739o-io7 ^ Other (specify equip. type and mod el in Sec. E on Pg. 2) City: Bakersfield Bldg. No.: Zip: 93307 Contact Phone No.: 661-393-7000 Tank ID: T$ LS Dyed 20000 gallons [x] In-Tank Gauging Probe. Model: 847390-107 ^ Annular Space or Vault Sensor. Model: ^ Piping Sump /Trench Sensor(s). Model: ^ Fill Sump Sensor(s). Model: ^ Mechanical Line Leak Detector. Model: U Electronic Line Leak Detector. Model: Campo-Miner U Tank Overfill /High Leval Sensor. Model: M739o-107 ^ Other (specify equip. type and model in Sec. E on Pg. 2) Tank ID: T$ Clear Diesel 12000 gallons [x] In-Tank Gauging Probe. Model: 847390-107 ^ Annular Space or Vault Sensor. Model: ^ Piping Sump /Trench Sensor(s). Model: ^ Fill Sump Sensor(s). Model: ^ Mechanical Line Leak Detector. Model: U Electronic Line Leak Detector. Model: Campo-Miller [x] Tank OverFll /High Level Sensor. Model: s4739o-107 ^ Other (specify equip. typs and model in Sec. E on Pg. 2) Dispenser ID: T-1 Clear Dispenser ID: T-2 L~ Clear n Dispenser Containment Sensor(s). Model: 794380-208 (~ Dispenser Containment Sensor(s). Model: 794380-208 [7 Shear Valve(s). [X] Shear Valve(s). ^ Dispenser Containment Float(s) and Chain(s). ^ Dispenser Containment Float(s) and Chain(s) Dispenser ID: T-3 Clear Diesel Dispenser ID: T-4 Unleaded [x] Dispenser Containment Sensor(s). Model: 794380-208 [x] Dispenser Containment Sensor(s). Model: 794380-208 [~ Shear Valve(s). U Shear Valve(s). ^ Dispenser Containment Float(s) and Chains(s). ^ Dispenser Containment Float(s) and Chain(s). Dispenser ID: T~5 Dyed U Dispenser Containment Sensor(s). Model: 794380-208 U Shear Valve(s). ^ Dispenser Containment Float(s) and Chain(s) more tanks or dispensers, copy this form. Dispenser ID: T-6 EPA Diesel [x] Dispenser Containment Sensor(s). Model: 794380-208 U Shear Valve(s). ^ Dispenser Containment Float(s) and Chain(s). every at C. Certification - I certify that the equipment identified in this document was inspected/services in accordance with the manufacturers' guidlines. Attached to this Certification is information (eg, manufacturers' checklist) necessary to varify that this information is correct and a plot plan showing the layout of monitoring equipment. For equipment capable of generating such reports, I have attached a copy of the report; (check all that apply) x^ System Set-up U Alarm history report Technician Name (print): Kristopher Icarus Signature: ~~„~ ~2l~w.A~-~ Certification No: B341os License No: 8oa9oa Testing Company Name: Confidence UST Services, Inc. Phone No: 80039-9930 Site Address: 2200 East Brundage Lane ,Bakersfield, CA 93307 Date of Testing/Servicing: 9!14!2007 Date of Testing/Servicing: 9/14/2007 "~ 7 D. Results of Testing/Servicing Software Version Installed: 123.02 Complete the following checklist: [x] Yes ^ No* Is the audible alarm operational? x Yes No* Is the Visual alarm operational? x Yes No* Were all sensors visually inspected, functionally tested, and confumed operational? x Yes ^ No* Were all sensors installed at the lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) x N/A operational? x Yes ^ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary ^ N/A containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initate positive shut-down? ^ Sump/Trench SensorsuDispenser Containment Sensors Did you confirm positive shut-down due to leaks and sensor failure/disconnected? [~ Yes; ^ No; ^ Yes ^ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no L] N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visual and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capasity does the alarm trigger? 90 ^ Yes* ^ No Was any monitoring equipment replaced? If Yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. ^ Yes* ^ No Was liquid found inside any secondary containment systems designed as dry systems? ^ Product; ^ Water. If yes, describe causes in Section E, below. x No* Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports, if applicable. x yeS No* Is all monitoring equipment operational per manufacturer's specifications? * In Section E below, describe how and why these deficiencies were or will be corrected. E. Comments: F. In-Tank Guaging /SIR Equipment: U Check this box if tank guaging is used only for inventory control. ^ Check this box if tank guaging or SIR equipment is installed. This section must be completed if in-tank guaging equipment is used to perform leak detection monitoring. Complete the following checklist: [~ Yes ^ No* Has all input wiring been inspected for proper enter and termination,including testing for ground faults? x Yes No* Were all tank guaging probes visually inspected for damage and residue buildup? x Yes No* Was accuracy of system product level readings tested? x Yes No* Was accuracy of system water level readings tested? x Yes No* Were all probes reinstalled properly? ^ Yes ^ No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section ~ below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): ^ Check this box if LLD's are not installed. Complete the following checklist: [~ Yes ^ No* For equip. start-up or annual equipment certification, was a leak simulated to varify LLD performance? (Check all that apply) Simulated leak rate: Cx]3 g.p.h.: ^0.1 g.p.h.; ^0.2 g.p.h.; [~ Yes ^ No* Were all LLD's confirmed operational and accurate within regulatory requirments? x Yes No* Was the testing apparatus properly calibrated? ^ Yes No* For machanical LLD's, does the LLD restrict product flow if it detects a leak? x N/A Lx] Yes No* For electronic LLD's, does the turbine automatically shut off if the LLD detects a leak? ^ N/A [~ Yes No* For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system is ^ N/A disabled or disconnected? Lx] Yes No* For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system ^ N/A malfunction or fails a test? ^ Yes ^ No* For electronic LLD's, have all accessible wiring connections been visually inspected? ^ N/A [~ Yes No Were all items on the equipment manufacturer's maintenance checklist completed? * In the section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: WHOLESALE FUEL '2200 E BRUNDAGE LN BAKESFIELD CA 93304 . _ ~ 1 T 4:UNLEADEU VOLl~}ME = 38i 7 GALS ULLAGE _ }6746 GALS 90°, ULLAGE= 14659 GALS TG ~,tOLUME = 3745 Gf-~LS HEIGHT - 28.92 INCHES WATER VOL = 0 GALS WATER = 0.00 INCHES TEMP = 86.9 DEG F SEP 14 r 2007 9:23 AI'9 - S1J4STEFi _STATI~-REPORT - ALL FUN+'rTIONS 6~CQR1`~L SY'STEhi SETUF SEF 14. 2007 9:23 AM ~ - SYSTEM UNITS ' T 5:L-S DYEB U.S• ` VOLUh}E _ } 695Ci GALS SYSTEhI LANGUAGE ULLAGE = 3613 GALS ENGLISH 9pr ULLAGE= 1556 GALS S~°STF.P't DATErT 1 hiE FORh}AT TC VOLUME = 16695 GALS MON DB YYYY HH:h1M:SS xM HEIGHT = 92.}8 IhfCHES ' WATER VOL = 0 GALS WHOLESALE FUEL WATER = 0.00 IE~HES 2200 E BRUNDAGE LN TEMP = 93.3 DEG F BAKESFIELD CA 93304 T 6:L-S BYED SHIFT TIME } }1:00 Phl VC~LUP1E _ } 5105 C,ALS SHIFT TIME 2 12:00 AM ULLAGE = 5458 GALS SHIFT TIME 3 l:OD AhP 3~ ULLAGE= 34D} GALS SHIFT TIME 4 2:00 AM TG VOLUME = 14589 GALS HEIGHT = 82.66 INf;HES TANK PER TST fVEEDED WRN WHOLESALE FUEL f,~•1TER VOL = 0 GALS DISABLED 2200 E RRUNDAGE LN WATER = 0. QO INCHES Tc)vIf ANN TST P:EEDED WRN BAKESF I ELD CA TEi~tP = 31 .7 DEG F F? I SABLED • 93334 LINE RE-ENABLE METHOD SEP l4. 2007 9:'23 AM T 7:L-S DYED PASS LINE TEST ,~ VOLUh1E _ '367 GALS ~ ULLAGE _ }9596 GALS LINE PER TST NEEDED WRN 3~ ULLAGE= 17539 GALS DISABLED SYSTEM STATU:-~ REPORT TG VOLUME = 962 GALS LINE flNN TST NEEDED WRN - - - - - - - - - - - - HEIGHT = 1}.2.0 INCHES DISABLED ALL FUPIGTIONS NORMAL WATER VOL = 0 GALS WATER = O.QO INCHES PRINT TC VOLUMES INVENTORY REPORT TEMP = 72.1 DEG F ENABLED TEMP COMPENSATION T }:L-S CLEAR. T B:GLEAR DI ESEL VALUE tDEG F ?: 60.0 VOLUhPE _ 4594 GALS ~ VOLUME = 275D GALS STICK HEIGHT OFFSET ULLAGE = 5406 GALS ULLAGE = 9250 GALS DISABLED 90r ULLAGE= 4406 GALS 9CWr. ULLAGE= S050 GALS TG i.FOLUA9E = 4533 GALS TC VQLUt tE = 273f~ GAI..S ~ H-FRf?TO~:{~L BATA FORMAT ' HEIGHT = 44.47 INCfiES HEIGHT = 26.SS INCHES HEIGHT WATER 1tOL = 0 GALS WATER VOL = D GALS DAYLIGHT SAVING TIME WATER = 0.00 INCHES DATER = 0.00 [NCHES ENABLED TEMP = 59.6 DEG F TEMP- = 75.5 DEG F ~ START DATE j APR WEEK 1 SUN START TIME j. T 2:L-S.DS'ED ~ ~ ~ ~ ~ END * * ~ ?~ ~ 2:00 AM VOLUh1E' = 3165 GALS END BATE ULLAGE = 6532 GALS OCT WEEK 6 SUN 90~ ULLAGE= 5532 GALS END TIME TC VOLUME _}22 uALS 2:00 AM HEIGHT = 33.63 INCHES WATER FEOL = 0 GALS RE-BIREGT LOCAL PRINTOUT WATER = O.QO IIdt;HES DISABLED TEMF = 92.0 DEG F EURO PROTOCOL PREFIX S T 3:CLEAR-DIESEL VOLUME = 4345 GALS ULLAGE = 16218 GRL.S ' 9~ ULLAGE= 1416} ~3ALS SYSTEhI SECURITY TC 1:'OLUME = 4255 GALS CORE 000000 HEIGHT = 3P .7} INCHES WAT1~'R VOL = 0 GRLS CUSTOM ALARM LABELS WATER = O. DO INCHES DISABLED TEMP = 30.5 DEG F Gf1C'fh1UNIGATIONS SETUP i FORT SETTIP!%S ~ :ONiNi Bt?ARD I t RS-232 } BAUD RATE : 9E~00 PARITY NONE STOP BIT I STOP DATA LEITH: 8 DATA RS-232 SECURITY CODE DISABLED AUTO TRANSMIT SETTIf~S AUTO LEAK ALARM LIMIT DISABLED AUTO HIGH WATER LIMIT DISABLED AUTO? OVERFILL L F N1 I T DISABLEII AUTO LOW PRODUCT DISABLEB AUTO THEFT LIMIT DISABLED AUTO DELIVERY START DISABLED AUTO DELIVERY END DISABLED AUTO EXTERNAL INPUT ON DISABLED AUTO EXTERNAL IPIPUT OFF DISABLED AUTO SENSOR FUEL ALAP.M DISABLED AUTO SENSOR fiJATER ALARM DISABLED AUTO SENSOR OUT ALARM DISABLED RS-232 ENB OF M~-`SAGE DISABLEB T 2:L-S DYED IN-TANK SETUP PRODUCT CODE - - - - - - - - - - - - THERMAL COEFF :.000450 TAPIK DIAMETER 95.00 T I:L-S CLEAR TANK PROFILE 1 PT PRODUCT CODE I FULL VOL I0000 THERMAL COEFF :. 000450 TANK BIAMETER 95.00 ' TANK PROFILE I PT FLOAT SIZE: 4. 0 IN. FULL VOL I0000 WATER WARNING 4.0 HIGH WATER LIMIT: 5.0 FLOAT SIZE: 4 .0 IN. N1AX OR LABEL 110E : 10000 • WATER tJARNfNG 4.0 OVERFFLL LIMIT 99w HIGH WATER LIMIT: 5.U 9800 HIGH PRODUCT 999 MAX OR LABEL VOL: I0000 9900 OVERFILL L I N1I T 9th: DELIVERY L I N1 I T I 9000 I00 HIGH PRODl~T 95i 9500 Lt?W PRODUCT 0 DELIVERI' LIMIT ~ Ii LEAK ALARM LIMIT: 75 10Ct SUDDEN LOSS LIMIT: 99 TANK TILT 2.95 LOW PRODUCT 0 FROBE OFFSET 0.00 LEAK ALARt~f LIMIT : 75 SUDDEN LOSS LIMIT: 99 TANK TILT 2.40 SIPHON MANIFOLIIED TANKS FROBE OFFSET 0.00 T#: NONE LINE MANIFOLDED TANKS T#: NONE SIPHON MANfFOLDED TANKS T#: NONE L I FdE h1APF i FOLDED TAtdKS LEAK M I N PERIODIC : I Oi T#: NONE 1000 " LEHK N1I N ANNUAL 1 f~ LEAK M I fd PER I OD I G: I~ 1000 Iona LEAK MIN ANNUAL IOi PERIODIC TEST TYPE 1000 STA NDARD ANNUAL. TEST FAIL FERIODIG 'TEST TYPE ALARM DISABLED STANDARD FERiODIC TEST FAIL ANNUAL TES-'T FAIL ALARM DISABLED ALARM DISABLED GROSS TEST FAIL PERIODIC TEST FAIL ALARM DISABLED ALARM DISABLED ANN TEST AVERAGING: OFF GROSS TEST FAIL FER TEST AVERAGING: OFF ALARM DISABLED TANK TEST NOTIFY: OFF ANN TEST AVERAGING: OFF PEk TEST At/ERAGING: OFF TNK TST SIPHON BREAK:OFF TANK TEST NOTIFY: OFF DELIVERY RELAY 1 MIN PUMP THRESHOLD : I0.00% TNK TST SIPHON BREAI:OFF DELI VERY DELAY I M I N PUMP THRESHOLD I 0.00%~ ' T 3:CLEAR-DIESEL PRODUCT CODE 3 THERMAL GOEFF :.DDD45D TANK DIAMETER : 12D.DD TANK PROFILE 2 PT FULL V4L : 2D563 FLOAT SIZE: 4.D IN. tfATER WARM ~ 4 . D H I Git WRIER L I P1 I T: 5. D MAX 4R LABEL VOL: 2D563 OVERFILL LIMIT 9D%6 . 285D6 HIGH PRODUCT 95> . 19535 DELIVERY LIMIT 1°/ 205 LOW PRtsDUCT D LEAK ALARM LIMIT: 75 SUDDEN LOSS LIMIT: 99 TANK TILT .- D.SD PROHE OFFSET D.OQ SIPHON MANIFOLDED TANKS Tit : NONE LINE MANIFOLDED TANKS Tit : NONE L£RIC M I N PERIODIC : f 0 a . 2D56 LEAK MIN RNtdUAL 2 D°~ 2D56 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:4FF DELIVERY DELAY I MIN PUMP THRESHOLD 2Q.Df~ T 4:UNLERBED PRODUCT CODE 4 THERMAL COEFF :. DO[}~OD TANK DIAMETEx f20.OD TRNK PROFILE I PT FULL VOL 2D563 FLOAT SIZE: 4.D IN. WATER WARN I tSG 4 . D HIGH trJATER LIMIT: 5.D P7AX OR LABEL V4L: 2D563 OVERFILL LIMIT 1% 2D5 HIGH PRt3DtICT 45.°: . 29535 DELIVERY LIP•tIT fi . 2D5 LOW PRODUCT 0 LEAK ALARM LIMIT: ?5 SUDDEN LOSS L I {°I I T : 99 TANK TILT D.OD PROBE OFFSET D.DO ' SIPHON MRNIFOLDED TANKS Tit: NONE LINE MANIF4LDED TANKS T#: NOPJE LEAK MFN PERIODIC: ID°a . 2D56 LEAK M! N APdNLhAL I D!4 . 2056 PEP. 14D I C TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLEB GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:4FF DELIVERY DELAY I MIN PLft'IP THRESl~iLD i D . DD°i T 5:L-S DYED PRODUCT CODE 5 THERMAL COEFF :.DDD~SD TRNK DIAMETER : 22D.DD TANK PROFILE I PT FULL VOL 2D563 FLOAT SIZE: 4.0 IN. 6JFITER WARN F hEG 4 . D HIGH WATER LIMIT: 5.0 MAX 4R LABEL V4L: 20563 OVERFILL LIMIT 95i . 29535 HIU'H PRODUCT 99~ . 2D35? DELIVERY LIMIT Ii 205 LOW PRODUCT D LEAK ALARM LIMIT: 75 SUDDEN LOSS LIMIT: 99 TALK TILT D.DD ~ PROBE OFFSET D.DD SIPHON MANIFOLDED TANKS Tit: NONE LINE hd4NIFOLDEB TANKS Ttt: NONE LEAK MIN PERIODIC: Its 2D56 LEAK I'i I N RNNURL I D~ 2D56 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL RLARP4 DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF ~ TNK TST SIPHON BREAK:4FF DELIVERY DELAY I f`4I N PUMP THRESHOLD lO.DDr T $:CLEAR DIESEL T 6:L-S DYED , T 7:L-S D1 ED PRODUCT CODE 8 PRODUCT GODS 6 PRODUCT CODE 7 THERMAL COEFF :. 000450 THERt'~L G4EFF :.000450 ' THERMAL COEFF :. 000450 ~ TANK DIAMETER 96.00 TANK DIAMETER 120.00 TANK DIAMETER 320.00 ' TANK PROFfLE i FT TANK FROFILE 1 PT TANK FROFILE I FT FULL VOL 32000 FULL t14L 20563 FULL VOL 20563 ~ FLOAT SIZE: 4.0 ItV. FLOAT SIZE: 4 .0 IN. FLOAT SIZE: 4 .0 IN. WATER WARNING 4.0 WATER k~RNING 4.0 WATER WARNING : HIGH WATER LIMIT: 4.0 5.0 H1GH,WATER LIP4IT: 5.0 HIGH WATER LIMIT: 5.0 MAX OR LABEL VOL: 20563 ~ MAX OR LABEL VOL: i 0563 htAX OR LABEL VOL: OVERFILL LIhIIT 12000 9~ OVERFILL LIP'IIT 90~ 4VERFfLL LIMIT 90% 10800 18506 HIGH PRODUCT 95a ' HfGH PRODUCT' 18506 95°a HIGH PRODUCT 11400 I9535 DELIVERI' LIMIT i% DELIVERY LIMIT 19535 i~ DELIVERY LFMfT F~ 120 • 205 205 LOW PRODUCT 0 LOW PRODUCT 0 LERKFALARhlTLIMIT: 75 LEAK ALARM LIMIT: 75 LEAK ALARM LIMIT: ?5 SUDDEN LOSS LIMIT: 99 SUDDEN LOSS LIMIT: 99 SUDDEN LOSS LIMIT: 99 TANK TfLT •- 5.00 TANK TILT .- 2.00 PROBE OFFSET 0.00 TANK TILT .- FROBE OFFSET '2.00 PROBE OFFSET 0.00 0.00 SfFHON hfANIFOLDED TANKS SIPHON MANIFOLDED T ANKS SIPHON htANIFOLDED TANKS T#: NONE T#: NONE LINE MANIFt?f.DED TANKS T#: NONE LINE MANIFOLDED TAN KS LINE MANIFOLBED TA N1:S T#: NONE T#: NONE T#: NONE LEAK t^11 N FER I OD I C : 10"% ' LEAK MfN PERIODIC: ~ I0~ LEAK M I N PERIODIC : 10% 1200 '056 ` 2056 LEAK MIN APJNUAL f0/ LEAK h1IN ANNUAL o ; I0/ LEAK MIN ANNUAL ~ 1200 2056 • '2056 PERIODIC TEST TYPE ti, FERIODIC TEST T,PE PERIODIC TEST TYPE STANDARD STANDARD STANDARD ANNUAL TEST FAIL ! ANNUAL TEST FAIL ANNUAL T'ESALARhiLDfSABLED ALARM DISABLED ~ ALARM DISABLED PERIODIC TEST FAIL PERIODIC TEST FRIL PERIODIC TEST FAIL ALARM DISABLED ALARM DISABLED ALARPi DISABLED GROSS TEST FAIL GROSS TEST FAIL GROSS TEST ALARM DISABLED ALARM DISABLED ALARM DI SABLED ANN TEST AVERAGING: OFF ANN TEST AVERAGING: OFF FER TEST AVERAGING : OFF PER TEST AVERAGIP~: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TANK TEST NOTIFY: OFF TANK TEST NOTIFY: OFF TNK "TST SIPHON BREAK:OFF TNK TST SIPHON BREAK :OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY 1 MIN DELIVERY DELAY t1 • PUP'lF THRESHOLD f 0.00' i PUMP THRESHOLD 10 MIN .00% THRESHOLD PUMP 10.00 OUTPLtT RELAY SETUP LEAK TEST METHOD TEST, MONTHLY ALL TAtdK WEEK 2 SUN START TIME : 2:00 AA4 TEST RATE :0.20 GAL~HR DURATION 2 HOLtRS TST EARLY STOP:DISABLED LEAK TEST REPORT FORNtAT NORt^4AL LIQUIT~ SEPtSC7R SETUP L I: D I S-PAPP,~ tdORPh~LLY CLOSED CATEGORY DISPENSER PAP! L 2:DIS-PANS NORMALLY CLOSED CATEGORY BISPENSER FAN L 3:DIS-PANS NORMALLY CLOSED CATEGORY D I SFEtdSER PAN R EPOS-EPA TYPE: STANDARD • NORMALLY OPEN IN-TANK ALARMS ' ALL:LEAK ALARM T ? :OVERFILL ALARt°t R 2:OUTSIDE ALARM TYPE: MOMENTARY NORMALLY OPEN LIGUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARP4 ALL:SHORT ALARM ALL:WATER OUT ALARM ALL:HIGH LIQUID ALARM R 3:PANS 1.2.3 TYPE: STANDARD t~RMALLY CLOSED LIQUID SENSOR ALFtS L I :FUEL ALARPI L 3:FUEL ALARM R 4:PAt~ 4.5.6 TYPE: STANDARD NORMALLY CLOSED ti LIQUID SENSOR ALFtS L 2:FUEL ALARM SOFTWARE REVISI<3N LEVEL VERSION 123.02 SOFTWARE# 346123-100-C CREATED - 02.II.25.15.17 NO SOFTWARE MODULE SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNC~L. IN-TANK TESTS ALARM HISTORY REPORT ----- SENSOR ALARt°t ----- ' L I:DIS-FANS DISPENSER PAid FUEL ALARiMt SEP 5, 2007 9:49 AN1 FUEL ALARM SEF 5r 2007 4:19 AM FUEL ALARM SEP 5r 2007 9: t 3 AWi ~ ~€ ~ END x ~ ~ =: RECONCILIATION SETUP AUTOMATIC DAILY CLOSING TIME: 2:00 AM PERIODIC RECONCILIATION MODE : MO NT FtLY TEMP COMPENSATION STANDARD BUS SLOT FUEL METER TANK TANK hfAP EMPTY ' ALARM HISTORM' REPORT ----- SENSOR ALARM ----- L 2:DIS-PANS DISPENSER FAN FUEL ALAF.Nt SEP 5, 2007 9:I9 ANt FUEL ALARM SEF 5. 2007 9:19 At~t FUEL ALARM SEP 5. 2007 9:19 AM ALAI2t°1 H I STQRY REP4RT ----- SENSt~R ALARM ----- L 3 : D I S-PAtdS DISPENSER FAN FUEL ALARM FEI3 26. 2!}Q7 t : Q2 FM FUEL ALARM FEB 18. 2Q47 11:24 FM FUEL ALARWf DEG 1I. 2I}Q6 8:27 AM ~~~~~iEND~?~n~ ---- I Ed-TANK ALARWI ----- T 1:L-S GLEAk HIGH PR{}I:iUGT ALARM SEF !4. 20Q7 9:3I AM ---- IN-TANK ALARM ----- T t:L-S GLFAR HIGH PRODUCT ALARM SEP 14. 20117 9:33 AM - - I t+f-TANK ALARM ----- T 2:L-S DYED HIGH PRODUCT ALARM SEP 14. 2007 9:33 AM ---- IN-TANK ALARM ----- tatHQLESALE FUEL T 3:GLF.AR-DIESEL 22QQ E BRUNDAGE LN HIGH PR~3DUC:T ALARWf BAI:ESI= I ELD GA SEF I4. 2QQ7 9:34 AM • 93304 ---- I N-TANK ALARfgi ----- T 4:UNLEADED HIGH PR£7DUGT ALARM SEP f4, 20Q7 9:34 AM SEP }4. 2Qt17 3:35 AM SYSTEM STATUS REPORT T s3 :HIGH FRC}DUG.T ALARM -- SENSt~R ALARM ----- L 2:DIS-FANS DISPENSER PAN ---- IN-TANK ALARM ----- FUEL ALARM T 5:L-S DYED SEP i4, 2DQ? 9:37 AM HIGH PRUDUGT ALARhf SEF I4. 2t1Q7 4:34 AP1 - -- SENS~JR ALARM ----- L 2:D1S-FANS ---- IN-TANK ALARM ----- DISFEt~aER FAN T 6:L-S DYED FUEL ALARM HIGhf PRt}DUGT ALARM SEF t4r 20Q7 9:37 AM SEP for 20Q7 '3:35 APf ----- SENSt?R ALARM ----- ---- IN-TANK ALARM ----- L 2:DIS-PANS T 7:L-S D`fED DISPENSER PAP! HIGH PRt}DUGT ALARM FUEL ALARhf SEP 14. 20L~7 9:35. Af~i SEF 14r 2E107 3:35 Ahf ---- IN-TANK ALARM ----- T B:GLEAR DIESEL HIGH PR©DUCT ALARM SEP t4. 20Q7 3:35 AC1 - r - ----- SENSQR ALARM ----- ' L 1:DIS-PANS DISPENSER PAN . FUEL ALARM SEP 14. 2Qa7 9:38 AM ----- SENSt~R ALARM ----- L 1:DIS-PANS DISPENSER PAN FUEL ALARM SEP 14, 2aa7 9:33 AM ----- SENSt~R ALARM ----- L I:DIS-PANS DISPENSER PAN FUEL ALARM ' SEP 14. ?a07 9:3Et ANi ' ----- SENS4k ALARM ----- L 3:DIS-PRNS DISPENSER PAN FUEL ALARP2 SEP 14, 2aa7 9:44 AM ----- SENSQR ALr'1RF1 ----- L 3:DIS-PANS DISPENSER PAN FUEL ALARM SEP I4. 2aa? 9:44 AM WNEsLESALE FUEL 22aa E BRUNDAE~E LN EtAKESFIELD CA 933x4 SEP 14, 2Qa7 9:4:3 AP'i SYSTEM STATUS REPORT ALL FUNt:TI6iVS NQRMAL SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (f applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Wholesale Fuels Date of Testing: 9/14/2007 Facility Address: 2200 East Brundage Lane ,Bakersfield, CA 93307 Facility Contact: Omero Garcia Phone: 661-393-7000 Date Local Agency Was Notified of Testing : 8/24/2007 Name of Local Agency Inspector (f present during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Kristopher Karns Credentials': X CSLB Contractor X ICC Service Tech. ^ SWRCB Tank Tester ^ Other (Specify) License Number(s): CSLB #804904 ICC #5264406-UT 3. SPILL BUCKET TESTING INFORMATION Test Method Used: x Hydrostatic ^ Wacuum ^ Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket (By Tank Number, Stored Product, etc. 1) T-1 2) T-2 3) T-3 4) T-4 Bucket Installation Type: ^ Direct Bury x Contained in Sump ^ Direct Bury x Contained in Sum ^ Direct Bury x Contained in Sump ^ Direct Bury X Contained in Sump Bucket Diameter. 12.00" 12.00" 12.00" 12.00" Bucket Depth: 16.50" 14.00" 14.75" 14.25" Wait time between applying vacuum/water and start of test: 5 min. 5 min. 5 min. 5 min. Test Start Time (TI): 9:35am 9:35am 9:35am 9:35am Initial Reading (R~): 13.50" 12.75" 12.50" 12.25" Test End Time (TF): 10:35am 10:35am 10:35am 10:35am Final Reading (RF): 13.50" . 12.75" 12.50" 12.25" Test Duration (TF - TI): 1 hour 1 hour 1 hour 1 hour Change in Reading (RF - RI): 0.00" 0.00" 0.00" 0.00" Pass/Fail Threshold or Criteria: 0.0625" 0.0625" 0.0625" 0.0625" Test Result: X Pass ^ Fail X Pass ^ Fail X Pass ^ Fail X Pass ^ Fail ____ _ -_ Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature: ~ }~ a,,,~-,~nA/ Date: 9/14/2007 ' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. .: ~ . SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of LIST spill containment structures. The completed form and printouts from tests (f applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Wholesale Fuels Date of Testing: 9/14/2007 Facility Address: 2200 East Brundage Lane ,Bakersfield, CA 93307 Facility Contact: Omero Garcia Phone: 661-393-7000 Date Local Agency Was Notified of Testing : 8/24/2007 Name of Local Agency Inspector (tf present during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Kristopher Karns Credentials': X CSLB Contractor X ICC Service Tech. ^ SWRCB Tank Tester ^ Other (Specify) License Number(s): CSLB #804904 ICC #5264406-UT 3. SPILL BUCKET TESTING INFORMATION Test Method Used: x Hydrostatic ^ Vacuum ^ Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket (By Tank Number, Stored Product, etc. I) T-5 2) T-6 3) T-7 4) T-8 Bucket Installation Type: ^ Direct Bury x Contained in Sum ^ Direct Bury x Contained in Sum ^ Direct Bury x Contained in Sump ^ Direct Bury X Contained in Sump Bucket Diameter. 12.00" 12.00" 12.00" 12.00" Bucket Depth: 17.00" 14.50" 15.50" 14.00" Wait time between applying vacuum/water and start of test: 5 min. 5 min. 5 min. 5 min. Test Start Time (TI): 9:35am 9:35am 9:35am 9:35am Initial Reading (RI): 15.75" 12.25" 13.50" 13.00 Test End Time (TF): 10:35am 10:35am 10:35am 10:35am Final Reading (RF): 15.75" 12.25" 13.50" 13.00" Test Duration (TF - TI): 1 hour 1 hour 1 hour 1 hour Change in Reading (RF - RI): 0.00" 0.00" 0.00" 0.00" Pass/Fail Threshold or Criteria: 0.0625" 0.0625" 0.0625" 0.0625" Test Result: X Pass ^ Fail X Pass ^ Fail X Pass ^ Fail X Pass ^ Fail Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature: ~` g~ Date: 9/14/2007 ' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. UNDERGROUND STORAGE TANKS APPLICATION TO PERFORM ELD /LINE TESTING / SB989 SECONDARY CONTAINMENT TESTING /TANK TIGHTNESS TEST AND TO PERFORIUI FUEL MONITORING CERTIFICATION PERMIT NO. ~~~'' a ~~-- a~ BAKERSFIELD FIRE DEPT. $ A~ 1~H_A_9 A I~'F'$ D ;, F~Re ~ Prevention Services Ds~$AR~>~frIT 900 Truxtun Ave., Ste. 210 _ = _~ Bakersfield, CA 93301 Tel.: (661) 326-3979 Fax: (661) 852-2171 Page t of 1 .2S ENHANCED LEAK DETECTION .eS UNE TESTING ,ES SB•989 SECONDARY CONTAINMENT TESTING .ES TANK TIGHTNESS TEST ~~T'9.PERFORM FUEL MONITORING CERTIFICATION SITE INFORMATION FACILITY ~ NAME $ PHORfE NUMBER OF CONTACT PERSON oar ~ 3 3 --16 ADDRESS 2240 _ a C 3 ~ OWNERS NAME OPERATORS NAlv7E PERMIT TO OPERATE RIO. NUMBER OF TANKS TO BE TESTED IS PIPING GOING TO BE TESTED? es YES rs NO TANK # VOLUME CONTENTS TANK TESTING COMPANY NAME OF TESTING COMPANY ~ "~ c R1ACaE & PHONE R1UC7BER OF CONTACT PERSON ~ 3 - ~ MAILING ADDRESs NAME $ PHONE NUMBER OF TESTER OR SPECIAL INSPECTOR ~' - CERTIFICATION #: 2 DCATE $ TI E TEST TO BE ONDUCTED J ~ ~ ~~ ICC #: TEST METHOD SIGNA RE OF APPLICANT DATE A RL. G Q ~-Gfl ESA ER il` E R OYE® APPROVED BY DATE ~ S FD 2095 (Rev. 09/05) t MONITORING SYSTEM CERTIFICATION ---•~~ o~} ~ ~ ~~~ For Use By All Jurisdictions Within the State of California ~, Authority Cited.• Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations ' This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control pane_1 by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of this date. A. General Information Facility Name: Wholesale Fuels,-Inc. Site Address: 2200 East Brundage Lane City: Bakersfield Facility Contact Person: Omero Garcia Make/Model of Monitoring System: Veeder-Root TLS-350 B. Inventory of Equipment Tested/Certified CRech the appropriate bozp to in cafe specific equipment inspeehd/serviced: Bldg. No.: Zip: 93307 Contact Phone No.: 661-393-7000 Date of Testing/Servicing: 9/18/2006 Tank ID: T-1 L-S Cleat 10000 gallons _ [X] In-Tank Gauging Probe. Mode1:847390-107 ^ Annular Space or Vault Probe. Model: ^ Piping Sump /Trench Sensor(s). Model: ^ Fill Sump Sensor(s):. .. Model: ^ Mechanical Line Leak Detector.. Model: [X] Electronic Line Leak Detector. Model: Campo-Miner U Tank Overfill /High- Level Sensor. Model: 8a739o-107 ^ Other (specify.equip. type and model in Sec. E on Pg. 2) Tank ID: T-3 Clear Diesel 20000 gallons U In-Tank Gauging Probe. Model:8a739o-1f)7 ^ Annular Space or Vault Sensor. Model: ^ Piping Sump /Trench Sensor(s). Model: ^ Fill Sump Sensors(s). Model: ^ Mechanical Line Leak Detector. Model: [X] Electronic Line Leak Detector. Model:Campo-Miller U Tank Overfill /'High Level Sensor. Mode1:847390-107 ^ Other (specify equip. type and model in Sec. E on Pg. 2) Dispenser ID: T-1 Clear ~x] Dispenser Containment Sensor(s). Model: 79a38o-208 [X] Shear Valve(s). ^ Dispenser Containment Float(s) and Chain(s). Dispenser ID: T-3 Clear Diesel [~ Dispenser Containment Sensor(s). Model: 794380-208 ~x] Shear Valve(s). ^ Dispenser Containment Float(s) and Chains(s). Dispenser ID: T-5 Dyed [~ Dispenser Containment Sensor(s). Model: 794380-208 U Shear Valve(s). ^ Dispenser Containment Float(s) and Chain(s) contams more tanks or dispensers, copy Tank ID: T-2 LS Dyed 10000 gallons [X] In-Tank Gauging Probe. Model: 847390-107 ^ Annular Space or Vault Sensor. Model: ^ Piping Sump /Trench Sensor(s). Model: ^ Fill Sump Sensor(s). Model: ^ Mechanical Line Leak Detector. Model: Ll Electronic Line Leak Detector. ~ Model: Campo-Miner U Tank Overfill /High Leval Sensor. Model: 8a739o-707 ^ Other (specify equip. type and model in Sec. E on Pg. 2) Tank ID: T-4 Unleaded 20000 gallons [x] In-Tank Gauging Probe. Model: 8a739o-107 ^ Annular Space or Vault Sensor. Model: ^ Piping Sump /Trench Sensor(s). Model: ^ Fill Sump Sensor(s). Model: ^ Mechanical Line Leak Detector.' Model: [~ Electronic Line Leak Detector.,,;,,.. Model: Campo-Miller ~x] Tank Overfill /High Level Sensor. Model: 8a739o-707 ^ Other (specify equip. typs and model in Sec. E on Pg. 2) Dispenser ID: T-2 L-S Clear [X] Dispenser Containment Sensor(s). Model: 79a38o-208 [X] Shear Valve(s). ^ Dispenser Containment Float(s) and Chain(s) Dispenser ID: T-4 Unleaded U Dispenser Containment Sensor(s). Model: 79a38o-208 U Shear Valve(s). ^ Dispenser Containment Float(s) and Chain(s). Dispenser ID: T-6 EPA Diesel [x] Dispenser Containment Sensor(s). Model: 794380-208 U Shear Valve(s). ^ Dispenser Containment Float(s) and Chain(s). information for every at C. Certification - I certify that the equipment identified in this document was inspected/services in accordance with the manufacturers' guidlines. Attached'>to this•Certification is information (e.g. manufacturers' checklist) necessary to varifythat this information is correct and a plot plan showing the layout of monitoring equipment. For equipment capable of generating such reports, I have attached a copy of the report; (check all that apply) 0 S tem Set _ Cx] Alarm history report Technician Name (print): Joseph stroope Signature. ~ ~ -~ Certification No.:=A-3~22s Licens o: 8oa9oa Testing Company Name: Confidence UST Services, Inc. Phone No: 80039-9930 Site Address: 2200 East Brundage Lane ,Bakersfield, CA 93307 Date Of Testlrig/Servlcing: 9N 8/2006 D. Results of Testing/Servicing Software Version Installed: 123.02 Complete the following checklist: [x] Yes ^ ]vo* Is the audible alarm operational? x Yes No* Is the Visual alarm operational? x yes No* Were all sensors visually inspected, functionally tested, and confumed operational? x Yes ^ No* Were all sensors installed at the lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) x N/A operational? x yes ^ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary ^ N/A containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initate positive shut-down? ^ Sump/Trench Sensors[X] Dispenser Containment Sensors Did you confirm positive shut-down due to leaks and sensor failure/disconnected? ^Yes; ^ No; ^ Yes ^ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no ^ N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visual and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capasity does the alarm tugger? 90 ^ Yes* ^ No Was any monitoring equipment replaced? If Yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. ^ Yes* ~ No Was liquid found inside any secondary containment systems designed as dry systems? ^ Product; ^ Water. If yes, describe causes in Section E, below. x No* Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports, if applicable. x yeS No* Is all monitoring equipment operational per manufacturer's specifications? * In Section E below, discribe how and when these deficiencies were or will be corrected. E. Comments: F. In-Tank Guaging /SIR Equipment: ^ Check this box if tank guaging is used only for inventory control. ^ Check this box if tank guaging or SIR equipment is installed. This section must be completed if in-tank gtzaging equipment is used to perform leak detection monitoring. Complete the following checklist: (X] Yes ^ No* Has all input wiring been inspected for proper enter and termination,including testing for ground faults? x Yes No* Were all tank guaging probes visually inspected for damage and residue buildup? x Yes No* Was accuracy of system product level readings tested? x Yes No* Was accuracy of system water level readings tested? x Yes No* Were all probes reinstalled properly? [~ Yes ^ No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be rnrrected. G. Line Leak Detectors (LLD): ^ Check this box if LLD's are not installed. Complete the following checklist: [~ Yes ^ No* For equip. start-up or annual equipment certification, was a leak simulated to varify LLD performance? (Check all that apply) Simulated leak rate: [X]3 g.p.h.: ^0.1 g,p.h.; ^0.2 g.p.h.; ^ Yes ^ No* Were all LLD's confirmed operational and accurate within regulatory requirments? x Yes No* Was the testing apparatus properly calibrated? ^ Yes No* For machanical LLD's, does the LLD restrict product flow if it detects a leak? x N/A [~ Yes No* For electronic LLD's, does the turbine automatically shut off if the LLD detects a leak? ^ N/A ^ Yes No* For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system is ^ N/A disabled or disconnected? [~ Yes No* For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system ^ N/A malfunction or fails a test? [~ Yes ^ No* For electronic LLD's, have all accessible wiring connections been visually inspected? ^ N/A x Yes No Were all items on the equipment manufacturer's maintenance checklist completed? * In the section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: ~~ .- f a" ~~r.til Y'-f yr w\.... `~~~^~t,e~...y.4'.~. _ ' I N-TAtVK SETUP COMMUNICATIONS SETUP , _ _ _ _ _ _ _ - _ - _ - PORT SETTINGS: COMNt BOARD 1 1RS-232? BAUD RATE 9600 PARITY NOtVE STOP BIT 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE DISABLED AUTO TRANSMIT SETTINGS: AUTO LEAK ALARM LIMIT DISABLED AUTO HIGH WATER LINIIT DISABLED AUTO OVERFILL LIMIT DISABLED AUTO LOW PRODUCT DISABLED AUTO THEFT LIMIT DISABLED AUTO DELIVERY START DISABLED AUTO DELIVERI' END DISABLED AUTO EXTERNAL INPUT ON DISABLED AUTO EXTERNAL INPUT OFF DISABLED AUTO SENSOR FUEL ALARM DISABLED AUTO SENSOR 6JATER ALARM DISABLED AUTO SENSOR OUT ALARM DISABLED RS-232 END OF NIESSAGE DISABLED T 1:L-S CLEAR PRODUCT CODE 1 THERMAL COEFF :.000450 TANK DIAMETER 95.00 y TANK PROFILE i FT 1 FULL VOL : 10000 FLOAT SI?E: 4.0 IN. WATER WARNING 4.0 HIGH WATER LIMIT: 5.0 MAX 4R LABEL VOL: 10000 } OVERFILL L I M I T 90°~ 9000 HIGH PRODUCT 95r 9500 DELIVERY LIMIT 1~ 100 LOW PRODUCT : 0 LEAK ALARM LIMIT: t5 SUDDEtV LOSS LIMIT: 99 TANK TILT 2.40 PROBE OFFSET 0.00 f SIPHON MANIFOLDED TANKS T#: NONE LINE MANIFOLDED TANKS T#: NONE t LEAK MIN PERIODIC: l0a 1000 LEAK MIN ANNUAL 10% loaa PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARNI D I BAWLED APIN TEST AVERAGING: OFF PER TEST Al/ERAG I tVG : OFF TANK TEST NOTIFY: OFF TPIK TST SIPHON BREAK:OFF DELIVERY DELAY 1 MIN PUMP THRESHOLD : 10.00`} ~~-~ o`_~ T 2 : L-S. DYED FRODUGT CODE 2 THERMAL_GQEFF :.000450 TANK DIAMETER 95.00 TANK PROFILE 1 FT FULL VOL 10000 FLOAT SIZE: 4.0 IN. InIATER WARNING 4.0 HIGH WATER LINIIT: 5.0 MAX OR LABEL VOL: 10000 OVERFILL LIMIT 990 9900 HIGH PRODUCT 99pa 9900 DELIVERY LIMIT 1°~ 100 LOW PRODUCT 0 LEAK ALARM LIMIT: 75 SUDDEPI LOSS LINIIT: 99 TANK TILT 2.95 PROBE OFFSET 0.00 SIPHON NiANIFOLDED TANKS T#: NONE ' LINE NiANIFOLDED TANKS T#: NONE LEAK N1IN PERIODIC: l0 1000 LEAK. N1I N ANNUAL 10%~ 1000 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARNi DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF FER TEST AVERAG I tVG : 4FF TANK TEST tVOT I FY : OFF TNK TST SIPHON BREAK:OFF , DELIVERY DELAY 1 MIN PUMP THRESHOLD 10.00r :,. ,...= PRODUCTAR~DDEESEL THERMAL C4EFF :.000450 TANK DIAMETER 120.00 TA(VK PROFILE i PT FULL VOL 20563 FLOAT SIZE: 4,0 IN. InIATER WARNING 4 , 0 HIGH WATER LIh1IT: 5,0 MAX 4R LABEL V4L: 20563 OVERFILL LIMIT g0~; 18506 HIGH PRODUCT 95~ DELIVERY LIMIT 1955 ' - 205 LOW PRODUCT 0 LEAK ALARM LIMIT: 75 SUDDEN LOSS LIMIT: gg TANK TILT .- 0,50 PROBE OFFSET O,Op -' SIPHON MANIF4LDED TANKS " T#: NONE LINE NIANIFOLDED TANKS T#: NONE LEAK MIN PERIODIC: 10%. . 2056 LEAK h1I N ANNUAL 10°~ 2056 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGINu^^: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELA1t' 1 M I N PUMP THRESHOLD 10.00°S k T 4:UNLEADED PRODUCT G4DE ~ THERMAL C~EFF :.000700 TANK DIAMETER 120.00 TANK PROFILE 1 FT FULL VDL 20563 FLOAT SIZE: 4.0 IN. IJATER WARNING HIGH WATER LIMIT: MAX OR LABEL VOL: OVERFILL LIMIT HIGH FRODIiCT . DELIVERY LIMIT . LOW PRODUCT LEAK ALARM LIh1IT: SUDDEN LOSS LIMIT: TANK TILT 'PROBE OFFSET 4.0 5.0 20563 90%~ 18506 95~~ 19535 to 205 0 75 9g 0.00 o.ao SIPHON MANIFOLDED TANKS T#: NONE LINE h1AN I FOLDED TANI;S T#: NONE LEAK hl I N PER I CAD I C: 10 2056 LEAK h1I N ANNUAL 10°~ 2056 PER I OD I C TEST Tl'FE STANDARL? ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ., ALARh! DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGIP~G: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:4FF PUMPVTHRESH4LD ~ 1 h1IN : 10.001 .~ T 5:L-S DYED PRODUCT CODE 5 THERMAL COEFF :.000450 TANK DIAMETER 1'20.00 TANK PROFILE i PT FULL VOL 20563 FLOAT SIZE: 4.0 IN. WATER WARNING 4.0 HIGH 4JATER LIMIT: 5.0 MAX OR • LABEL IDOL : 20563 OVERF I L:L L I M I T 95'~ 19535 HIGH PRODUCT 99°~ 20357 DELIVERY LIMIT 1r5 205 LOW PRODUCT : 0 LEAK ALARM L I hl I T : 75 SUDDEN LOSS LIMIT: 99 TANK TILT 0.00 PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS T#: NONE LINE MANIFOLDED TANKS T#: NONE LEAK MIN PERIODIC: l0ra . 2056 LEAK MIN ANNUAL 10°~ . 2056 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM D I SABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF FER TEST AVERAGINu^^: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY 1 MIN FUNIP THRESHOLD l 0 , 00f T 6:L-S DYED FR4DUCT CODE 6 THERMAL COEFF :.000450 TANK DIAMETER 120.00 TANK PROFILE 1 FT FULL VOL 20563 FLOAT SIZE: 4.0 IN. WATER WARNING 4.0 HIGH 4JATER LINIIT: 5.0 MAX OR LABEL VOL: 20563 OVERFILL LIMIT 90%5 18506. HIGH PRODUCT 95%5 19535 DELIVERY LIMIT 1%~ . 205 LOW FRODUCT 0 LEAK ALARM LIMIT: 75 SUDDEN LOSS LINIIT: 99 TANK TILT .- 2.00 PROBE OFFSET 0.00 SIFHON MANIFOLDED TANr;S T#: NONE LINE MANIFOLDED TANKS T#: NONE LEAK MIN PERIODIC: 10%5 • 2056 LEAK MIN ANNUAL lOf 2056 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARNt D I BAWLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED AtVN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERI' DELAY 1 MIN PUMP THRESHOLD 10.00%5 T 7:L-S DYED PRODUCT CODE 7 THERMAL'COEFF :.000450 TANK DIAMETER 120.00_ TANK FROFILE 1 PT FULL VOL 20563 FLOAT SIZE: 4.0 IN. I.JATER WARNING 4.0 HIGH WATER LIMIT: 5.0 MAX OR LABEL VOL: 20563 OVERFILL LIMIT - 90f 18506 HIGH PRODUCT 95a . 19535 DELIVERY LIMIT if . 205 LOW PRODUCT 0 LEAK ALARM LIMIT: 75 SUDDEN LOSS LIMIT: 99 TANK TILT .- 2.00 PROBE OFFSET 0.00 SIPHON MAN I FOLDED TANKS T#: NONE LINE MANIFOLDED TANKS T#: NONE LEAK N1 I N PERIODIC : 10.°~5 . 2056 LEAK MIN ANNUAL 10~ 2056 PERIODIC TEST TYFE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARh9 D I SABLEU ANN TEST AVERAGING: OFF PER TEST AVERAGItG: OFF TANK TEST NOTIFY: OFF TtVK TST SIPHON BREAK:OFF DELIVERY DELAY 1 MIN PUMF THRESHOLD 10.00°d T B:CLEAR DIESEL s FRODUCT CODE . THERMAL COEFF :.000450 TANK DIAMETER 96.00 TANK PROFILE 1 FT FULL VOL 12000 FLOAT SIZE: 4.0 IN. WATER WARNING : HIGH 6JATER LINIIT: 4.D 5.0 MAX OR LABEL 114L: 12~~0 OVERFILL LINIIT 10800 HIGH PRODUCT 95° 11400 DELIVER' LIMIT 12 LOW PRODUCT LEAK ALARM L I NI I T : 0 75 SUDDEN LOSS LTMIT_ 00 5 TANK TILT PROBE OFFSET . 0.00 SIFHON MANIFOLDED TANKS T#: NONE LINE MANIFOLDED TANKS T#: NONE LEAK MIN PERIODIC: 1200 LEAK MIN ANNUAL 12~ PERIODIC TEST T1`STANDARD ANNUAL TESTAL~RMLDISABLED PERIODIC TEALTAp~ADj~ABLED GROSS TESTALARi DISABLED F~ ANN TEST AVERAGING: ~• 'PER TEST AVERAGING: OFF ~, STANK TEST NOTIFY: OFF , !• jTNK TST SIPHON BREAK:t~F~F ~ DEL I VERY' DELAY 1~ ~Nh1`N ~PUMF THRESHOLD : , 1~~'~i0%a ~ { •~ `. i .,_J ' T.; . LEAK-TEST METHOD ~ ,` TEST MQNTHLY ALL TANK#_ WEEK 2 SUN ' START TIME 2:00 ANf TEST RATE :0.20 UAL.f HIS ~r DURATIQN 2 HOURS TST EARLY STOP:DI~ABLEL~. LEAK TEST REPORT FORMAT, N4Rt°1A, 1 1 ` { LIQUID-SENSOR-SETUP -• L 1:DIS-FANS tVORNiALLY CLOSED ~ i CATEGORY DISPENSER P1 ~ L 2:DIS-PANS ~ NORMALLY CLOSED CATEGORY DISPENSER PAN i L 3:DIS-FANS ~ N0RMALLI' CLOSED CATEGQR4' DISPENSER'"PAN ter" t j ! j ~QUTPUT RELAY SETUI> - - - - - - - IR 1:P0S-EPA ~TYSTANDARD ~NQRMALLY OFEN ~~ ~~ _ I IIT 7~Ot}ERFILLSALARM y'°: i R 2:0UTSIDE ALARM: •~ ~ TYPE : ~ , , MONiENTARY t~ ~N4RNIALLY OPEN ;I IL I CCU I D SENSOR ALN1S f ~ ALL:SENSORLOUT AY.ARM ` ALL:SHQRT ALARM f ALL:HIA'GHRLIGUIDLAL~~ s i t IR 3:PANS 1.2.3 ) ~ f Tl'PE STANDARD I NORMALLI' CLOSED f! LIQUID SENSOR ALMS L 1:FUEL ALARM L 3 : FUEL ALARM ` ~R 4:PANS 4.5.6 ',. j ~ TYPE STANDARD ~NQRMALLY CLOSED LIQUID SENSOR ALMS -;I L 2:FUEL ALARM . T-~ } i ~, .~RECONCILIATIf~N SETUI;~ ~ ~. !- - - - - - ~AUTQMAT I C DAILY CLi~ `1't~J~~ TIME: 2:00 AN1 a ~'~jPERIODIC RECONCILIA'fI~N,~, € MODE: h1Qh~TFi~.'~` ~ ~ ~ s TEMP COMPENSATION STANDARD ~' BUS SLOT FUEL METER `I'rl~l ~- - - - - - - - r `_ TANK MAP EMPTY ~. ~ ±' 1 ~ j 'i a 1 I~ ' a ';SOFTWARE RE~r I S I O N` L.B~ ~ z iVERSION 123.02 ~SOFTWAREtt 34b123-107 C , ,t,REATED - 02.1 1 .25.1 ~ .17 ~ ~NO SOFTWARE MODULE ' ~S1'STEM FEATURES : FER I OD I C I N-TANK TF,ST,`'~ ANNUAL IN-TANK TES ~l ALARM HISTORY REPt~R'f ~' ----h~~ SENSOR ALARM ------ L i:DIS-PANS i a~. DISPENSER FAN FUEL ALARM ~ ~ ~h1AR 18r 2006 I2:5~ GSM .~ ~ FUEL ALARNI JAN 3. 2006 9:0"J Ah9 <~ FUEL ALARM >~ JAN 1. 2006 3:45 Pf9 '~ 1 t n Y i E a_ ~ i ~ i i z ? ~ ~ * ~ ~€ END ~ * ~ P . ! + ' '" ,~ iY. \ i ~ ~ALAR iNiN 'H.I STORY REPORT. ~. ~ ~ ,- ~, -- SENSOR -ALARM - ; L 2:DIS-FANS ~s. DISFENSER PAN i'q: FUEL ALARM ~_ ~h1AR 18. 2006 5: I $ l '~ ;.. _ FUEL ALARM ` ~ JAN 3. 2006 9:02 AM, '~ FUEL ALARM ,~ ,JAN 1,-2006 1:55 FM ~ r ~f ~ ~ I •ALARM HISTORY,REFi ((RY` ,~'. ' 'L 3:DISEFANS ALARt~~• DISPENSER FAN ' ~ - _IFUEL ALARM ~ ~ "` f(APR 14. 2006 2:19~FM ~' ~r MARL 3LA2006 6:20 'PM ~ ~~ ~-`~:_FUEL ALARM MAR 3, 2006 4: DD PP7~ ~ ~ ~ END ALARM HISTORY kEFORT -- SENSOR ALARNI -- L 4: --- OTHER SENSORS ~s~~~~END~~~€~~€ -- SENSOR ALARNI ----- L 2:DIS-FANS DISPENSER FAN FUEL ALARM. SEF 18r 2006 8:18 AM i _ -= SENSOR ALARM ----- L 2:DIS-FANS DISPENSER PAN FUEL ALARM SEP 18. 2006 8:19 At°I -- -- SENSOR ALARM ----- L 2:DIS-FANS DISPENSER FAN FUEL ALARt°t SEF 18. 2Q06 8:19 Ahl -- SENSOR ALARM ----- L 1:DIS-PANS DISFENSER FAN FUEL ALARM ..~.. SEP 18, 1006`,8:19 AM ~\ ~ ~~. ,~-~ SENSOR ALARt°1 L 1:DIS-PA(VS DISPENSER PAN FUEL ALARNI SEF 18. 2006 8:20 Aht ~~ r . -~ _, \ SENSOR ALARM L 1:DIS-PANS DISPENSER FAN FUEL ALARM SEP 18. 2006 8:20 Aht ----- SENSOR ALARt°1 ----- L 3:DIS-PANS DISPENSER FAN FUEL ALARhI SEF 18r 2006 8:'21 Af41 ,,., ..,,~.----~-.._P- _ _-.~._.,~- . - ~_~-: c,-~ D~EV - VOLUP9E_~ v--- 1 X033- GAL-S~"- J -UI:L"ASE . = 153a GALS g03a ULLAGE° jS761 GALS TC VOLUNIE =j 04 , 68 I NCHES HEIGHT 0 GALS WATER VOL = 0,00 INCHES WATER = 91,7 DEG F TEMP T 6:L-S DYED11823 GALS VOLUME = 87gp GALS ULLAGE _ 6653 GALS 90/ ULLAGE = 11665 GALS TC V©LUh1E = 67 , 08 I NCHES HEIGHT 0 GALS WATER,VOL = 0.00 INCHES WATER ~ ~ = 8g,6 DEG F TEMP ~--.~ T 7:L-S DYED 9746 GALS VOLUME = 10817 GALS ULLAGE _ gp^, ULLAGE _ 8f60 GALS 9687 GALS TC VOLUME 57 55 I NCHES - HEIGHT WATER VOI- _ 0 GALS 00 INCHES 0 WATER = , 73,5 DEG F TEMP T g:CLEAR DIESEL VOLUME = 10045 GALS ULLAGE 1755 GALS 90o ULLAGE = 9981 GALS TG VOLUME = 74.90 INCHES HEIGHT 0 GALS WATER VOL _ 0,00 INGHES WATER = 73.9 DEG F TEMP ~ * ~ ~ * END ~ '~ WHOLESALE FUEL 2200 E BRUNDAGE LN BAKESFIELD CA . 93304 SEF 18, 20L16-- 8-:-06 AM - SYSTEPI-STATUS-kEPORT - ALL FUNCTIONS (VOR(°lAL I NVENTOR1r` kEFORT T 1:L-S CLEAR VOLUP1E = 8315 GALS ULLAGE = 1685 GALS 90~ ULLAGE= 685 GALS TC VOLUME = 8202 GALS HEIGHT = 73.62 INGHES WATER VOL = 0 GALS UJATER = G . 00 INCHES TEMF = 90.1 DEG F T 2:L-S DYED VOLUME = 8996 GALS ULLAGE = 1004 GALS 90~ ULLAGE= 4 GALS TC VOLUh1E = 8878 GALS HEIU'HT = 80.09 INCHES WATER VOL = 0 GALS WATER = 0.00 INCHES TEMF = 89.0 DEG F T 3:CLEAR-DIESEL VOLUME = 17931 GALS ULLAGE = 2632 GALS 90%o ULLAU'E= 575 GALS TG VOLUNiE = 17725 GALS HEIGHT = 97.72 INGHES WATER VOL = 0 GALS WATER = O.OG INGHES TENiF = 85.5 DEG F T 4:UNLEADED VOLUME = 9935 GALS ULLAGE = 10628 GALS -90% ULLAGE= 8571 GALS TG VOLUME = 9140 GALS HEIGHT = 58.41 ItVCHES IrJATER VOL = 0 GALS WATER = 0.00 INCHES TEMP = 88.0 DEG F SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Wholesale Fuels Date of Testing: 9/18/2006 Facility Address: 2200 East Brundage Lane ,Bakersfield, CA 93307 Facility Contact: Omero Garcia Phone: 661-393-7000 Date Local Agency Was Notified of Testing : 8/17/2006 Name of Local Agency Inspector (f present during testing: 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Joseph Stroope Credentials': X CSLB Contractor X ICC Service Tech. X SWRCB Tank Tester ^ Other (Sped) License Number(s): CSLB #804904 ICC #5258844-UT Tester # 061720 '~' 3. SPILL BUCKET TESTING INFORMATION Test Method Used: x Hydrostatic ^ Vacuum ^ Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket (By Tank Number, Stored Product, etc. 1) T-I 2) T-2 3) T-3 4) T-4 Bucket Installation Type: ^ Direct Bury x Contained in Sum ^ Direct Bury x Contained in Sum ^ Direct Bury x Contained in Sum ^ Direct Bury X Contained in Sum Bucket Diameter: 12.00" 12.00" 12.00" 12.00" Bucket Depth: 17.00" 14.50" 15.50" 14.00" Wait time between applying vacuum water and start of test: 5 min. 5 min. 5 min. 5 min. Test Start Time (T~: 8:15am 8:15am 8:15am 8:ISam Initial Reading (RI): 17.00" 14.50" 15.50" 14.00" Test End Time (TF): 9:15am 9:15am 9:15am 9:15am Final Reading (RF): 17.00" 14.50" 15.50" 14.00" Test Duration (TF - TI): I hour 1 hour 1 hour 1 hour Change in Reading (RF - RI): 0.00" 0.00" 0.00" 0.00" Pass/Fail Threshold or Criteria: 0.0625" 0.0625" 0.0625" 0.0625" Test Result: X Pass ^ Fail X Pass ^ Fail X Pass ^ Fail X Pass ^ Fail Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby cert~ that all the information contai din this report is true, accurate, and in full compliance with legal requirements. Technician's Signature: Date: 9/18/2006 ' State laws and regulations do not currently requve testing to be performed by a qualified contractor. However, local requirements may be more stringent. . rr This form is intended for use by contractors performing annual testing of 21ST spill containment structures. The completed form and printouts from tests (f applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Wholesale Fuels Date of Testing: 9/18/2006 Facility Address: 2200 East Brundage Lane ,Bakersfield, CA 93307 Facility Contact: Omero Garcia Phone: 661-393-7000 Date Local Agency Was Notified of Testing : 811712006 Name of Local Agency Inspector (fpresent during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Joseph Stroope Credentialsi: X CSLB Contractor X ICC Service Tech. X SWRCB Tank Tester O Other (Spec fy) License Number(s): CSLB #804904 ICC #5258844-UT Tester #061720 3. SPILL BUCKET TESTING INFORMATION Test Method Used: x Hydrostatic ^ Vacuum ^ Other Test Equipmem Used: Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket (By Tank Number, Stored Product, etc. 1) T-5 2) T-6 3) T-7 4) T-8 Bucket Installation Type: O Direct Bury x Contained in Sum ^ Direct Bury x Contained in Sum ^ Direct Bury x Contained in Sum ~ Direct Bury X Contained in Sum Bucket Diameter. 12.00" 12.00" 12.00" 12.00" Bucket Depth: ) 7.50" 15.50" 13.50" 15.50" Wait time between applying vacuum/water and start of test: 5 min. 5 min. 5 min. 5 min. Test Start Time (T~: 8:15am 8:15am 8:15am 8:15am Initial Reading (R~: 17.50" 15.50" 13.50" 15.50" Test End Time (TF): 9:ISam 9:15am 9:15am 9:15am Final Reading (RF): 17.50" 15.50" 13.50" 15.50" Test Duration (TF - T~: 1 hour 1 hour 1 hour 1 hour Change in Reading (RF - R~: 0.00" 0.00" 0.00" 0.00" Pass/Fail Threshold or Criteria: 0.0625" 0.0625" 0.0625" 0.0625" Test ResWt.: X Pass : ^ Fail : X Pass EI Fail X -Pass ~ Faii X Pass ` D Fail Comments - (include information on repairs made prior to testing, and recommended foliaw-up for failed tests) Spill Bucket Testing Report Form SWRCB, January 2006 CERTIFICATION OF TECHIVICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify shat aU the information contained in this report is true, accurate, and in fuU compliance with legal requirements. Technician's Signature: Date: 9/18/2006 ' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements maybe more stringent. B F/BE ARTM f March 31, 2006 RONALD J. FRAZE FIRE CHIEF Mr. Robert Hardcastle Gary Hutton, Wholesale Fuels, Inc. Senior Deputy Chief 2200 E. Brundage Lane Administration 326-3650 Re: Failure to Perform /Submit Annual Fuel Monitor Certification Deputy Chief Dean Clason I~C~TICE OF VIOLATION & Operations/Training SCI~EDULE FOR COMPLIANCE 326-3652 Deputy Chief Kirk Blair ~ Dear Robert Hardcastle, Fire Safety/Prevention Services 326-3653 Our records indicate that your fuel monitor certifications is due/past due on 03-25-06. 2101 "H" Street ~ You are or will be in violatit~n of Section 2638(a) California Code of Regulations, Bakersfield, CA 93301 Title 23, Division 3, Chapter' 16. OFFICE: (661) 326-3941 FAX: (661) 852-2170 "All monitoring equipment shall be installed, calibrated, operated and maintained irr trccordance with manufacturers instructions, and certified every 12 months for operability, proper operating condition, RALPH E. HLTEY, DIRECTOR and proper calibration." PREVENTION SERVICES ' FlRE SAFETY SERVICES • ENVIRONMENTAL SERVICES i Therefore you have 30 days (Apri12'7, 2006) to comply. Failure to comply may 900 Truxtun Avenue, Suite 210 result in revocation of your Permit to Operate. Bakersfield, CA 93301 OFFICE: (661) 326-3979 Should you have any questir-ns, please feel free to contact me at 661- 326-3190. FAX: (661) 852-2171 David Weirather Sincerely yours, Fire Plans Examiner 326-3706 Ralph E. Huey, Director of Prevention Services Howard H. Wines, III f ~ ,~ Hazardous Materials Specialist .~%~ ~~~ 326-3649 ~ By: Steve Underwood ' Fire Prevention Officer REH/SU/db "Serving the Community F'orJl~lore ~IrianA Century" UNDERGROUND STORAGE TANK APPLICATION TO PERFORM LINE TESTING /TANK TIGHTNESS TEST /SB989 SECONDARY CONTAINMENT TESTING PERMIT NO. ~ T ~ ~~ BAKERSFIELD FIRE DEPT. Prevention Services B S R S F I ~ 900 Truxtun Ave., Ste. 210 P/Re Bakersfield, CA 93301 w~ r Tel: (661)326-3979 Fax: (661) 852-2171 Page 1 of 1 U TANK TIGHTNESS TEST FACILITY , \/ v ~ 0../R--~ OPERATORS NAME OWNERS NAME .~-> NUMBER OF TANKS TO BE TESTED TANK N0. ~' ~~~ U LINE TESTING ~-~ t SECONDARY CONTAINMENT TESTING PERMIT TO OPERATE NO. 1 ~~ k~-~ TANK TESTING COMPANY ' I'' ~K MAILING ADDRESS l NAME & PHONE NUM ``EAAR OF CONTAC i`~~~ TEST METHOD NAME OF TESTER OR PE AL INSP C 0 /'/s~'ll DATE & TIME TEST IS TO BE CONDUCTED e~ y t~0~ SIGNATURE OF APPLICA /) APPROVED ~ ~;- ` .._ /// IS PIPING GOING TO BE TESTED ^ YES ~NO CONTENTS VOLUME ~1/I~l~ LG~ a '~~ S ~ / 4~ ~j~GcfQ A2~~Fz~d~~¢ ~Ie% e5 i4~ ~ -~-~~ v ~, ~ r._ ,C- loc./ t.~-G t~ O _ __ _ CERTIFICATION_NO. _ a. TE ~ o ~a ru~ub4 cAe~.oy December 1, 2002 Wholesale Fuels P O Box 82277 Bakersfield CA 93380 2277 FIRE CHIEF RON FRAZE CERTIFIED MAIL ADMINISTRATIVE SERVICES 2101 'H' Street Bakersfield, CA 93301 VOICE (661) 326-3941 ~^x iOOl)395-1~n~ FINAL REMINDER NOTICE suP.RESS,O. SE.V,CES JANUARY 1, 2003 DEADLINE Bakersfield, CA 93301 vo,cE (66,)~26-394, ~Z Z-CO0 Ty.. ua FAX (661) 395-1349 Dear Tank Owner/Operator: PREVENTION SERVICES ,,,~,s~Es.,~o,.,,~,,,..~,,,:,, You will be receiving this letter on or about December l, 2002. One 1715 Chester Ave. Bakersfield, CA ~m01 month from today, January 1, 2003, your current underground VOICE (661) 326-3979 FAX (661) 326-0576 storage tank(s) will become illegal to operate. Current law would require that your permit be revoked for failure to perform the PUR,,C EDUCATIOn necessary Secondary Containment testing. 1715 Chester Avb. Bakersfield, CA 93301 VOICE (661) 320-3696 FAX (661)326-0576 In reviewing your file, I see that you have received "Reminder Notices" since April of this year. This is your last chance to comply F,RE,NVESTIC~TION with code requirements for Secondary Containment testing prior to 1715 Chester Ave. Bakersfield, CA 9..3,301 January 1, 2003. VOICE (66.1) 326-395'1 FAX (661) 326-0576 Should you have any questions, please feel free to contact me at 661- TRAINING DIVISION 326-3190. 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 -- -.,Rincerelv, FAX (661) 399-5763 Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/dc 06 /)7 01 09:08 "~6~e2{5 0576 BI-'i) }tAZ MAT DIV Permit CITY OF BA~RSFIELD OFFICE OF ENWIRONMENTAL SER~CES 1715 Chester Ave., Bakersfield, CA (805) 326-3979 PERMIT APPLICATION TO CONSTRUCT/MODIFY UNDERGROUND STORAGE TANK TYPE OF APPLICATION (CHECK) I ]NEW FACILITY ~MODIYlCATION OF FACILITY [ INEW TANK ~ST^r.1ATION ^r EXISTING ?^CaXTY STARTING DATE I~'" ! °O ~ _ PROPOSED COMPLETION DATE TYPE OF BUSIN'ESS ~'3o~ OA.. ~ r"o~..~. .... APN # CONTRACTOR ,__~o~,~.-r t~=t~'~t, C^LICENSENO.~6/'~,~. ?~osz so. ~r. ~a :Baa-o ~,~, o . SA~nE~D crrY ~usnmss uc~ss so. ,,~ ~,,~ BRIEFLY DESCRIBE THE WORK TO BE DONE ~'e-x,~_20. ~,~.o~. k/~.~olt,. ~r.?r~ TO O~O0-t¢O Wim~ /~5'' -' o---- SOre VY~r Da,~cr~o Ar srm NO. OF TANKS TO BE INSTArJ.h'33 I~ ARE THEY FOR MOTOR FUF_L ' .~ _YES NO SPILL PREVE--2CTION CONTROL AND COUNTER ~URES PLAN ON FILE ? YES NO s:cnos ~o. ~o:ou nm: T,~N'K NO. VOLUME UNIW. ADF~D REGbZAR PREMIUM DmSEL AVIATION SBCTIO~ FOR NON MOTOR FLrEL STORAGE TANK NO. VOLUME C~CAL STORED CAS NO. CHEMICAL PREVIOUSLY STORED eno 8P,~CD NaMZ) CrF KNOWN) FOR OFFICIAL OS£ ONLY' THE APPLICANT HAS RECEIVED, UNDERSTANDS, AND WILL COM]PLY WlTH THE ATTACHED CONDITIONS OF AND FEDEKAL REOULATIONS. THIS PERMIT AND.ANY OTI~R STATE, LOCAL '"THIS APPLICATION IBECOMES A PERMIT W(I-[EN APPR~D EXPLANATION AMOUNT SUNSET CONSTRUCTION 14 0 9 3812 PANORAMA DR. BAKERSFIELD. CA 93306 PH. (661) 871-1788 16-24-1220 PAY AIdOUNT DO r~ T ~: TO THE ORDER OF DESCRIPTION C,ECK AMOUNT ' ' NUMBER WELLS FARGO BANK ~~ ,'DO i, L, OCl,' ~-' l, ~ ~000 ~h ?~10 ?F= t hOP, Ct :J ?.' 17::- VI' X" '., .JI¡JL 29 ~~O... ·1....38. '. . CITY OF BAIØtRS~J .D . . . . OlFIÇE QF ENYIR(j.~4L.S~ltVlÇES, '. 171~' CheS~ Ave., BaJt~.I~,~ C~, ~6~1) .32.6..~97.9 :. . . .,.... . : .' .:. ·.:·i;r.f:].··.:.·~··;·· .:' ." . "., ." " APPLICATlONTO.P@RM ': . . FUEL MONITORING ~R~C"'TIØN PACIUI'Y ~ . . . ~m:RS~ d_ ;" _ ~'¡'~:.'P',~:~ .' , OWNEaSNAMB \."""~~ NAMEOFMONn'ORMANUF~ ......: { . ~'~ .1#¢¿u:.'rL. OOBSPACJUrYHAVBDISPSNSBRPANS? YEB)c?·)I.·· NO~ . B (~FLD'FIR~ PRL.y :nl.1UI'..,.y,r"..,'~"'''''~'''''' _.._ . ' . ..... '.' ;~~d ...... . '. · ,):;f' ", :' : ~ "; . ''''" , . . ..' ~ . · " .. · . "'0 . ",' . . . . ;:: : '.)::( . . " " : '. . ~: . .;. ;" ~~i' . . " '. · : I ~ :..:!. c '. . ... . . " '':'\''.'' . 'f c TANK' I ,9 :3 ¿j o/'t,. VOLUME /Ó" tp(JI~. - '. . ......!:..~ . . . .CO~· , .-^ ^. ';"'¡.a:. . ~.~~ F CM.'-.l, ~ . tN\. \1. f. IAA \.\l~ f . . . '\ " " '1' " .;;.~. ',t.:.: . . " /ð, (; tJ& . - ~~ tp~t:.tÞ- . ., . ::l ðj ÒtJ)4J - . ~4 ¿ltfIO - . <. ~ · .~ . . ". ~';:~'. ~.~ ; I'i~ ,.... . .\'1'," .. . . . .' . . ~ .~. ':.;' NAMEQPTBSTINQCOMPANY Sv~í øc~Hþ&Lt44¿ . CoNTRAcroR.S LIa!NSB #. ~&?-5'" /"7 .: .'~ . ',' '" . NAME &: PHONE NUMBÈR OHCONTACTmoNJl1lt~ ~v"?IO~\97f--?69~ DATE & TIMB 'l'BST IS TO'BB CONDUCTED: 9'-11Z~D cf a ß~·OO ~ vA.... ~ cØd4~ ~" , -"~;.,,, . .~ ~ ( APPRqVBD BY :PAn ':¿;:'",; .... · '':':,: ;,~:. . .. " .. lø 3Ð'¥"d 1.3SNnS lLø9llE199 99:131 Pøøl/9t/6ø ·, ',' '-ý , ..' ;t,. MONITORING SYSTEM CERTIFICATION : For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to docume* testing and servicing of monitoring equip¡p.ent. A separate certification or report must be prepared for each monitoring system contro!'panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information i Facility Name: Wholesale Fuel's . I Site Address: 2200 E. Brundage Lane --..., I Facility Contact Person: 6ci\?:.':::o. tf\\f.\.Q.Dè.'...lf\.:') ''-\E... Make/Model of Monitoring System~·-t''d:;''. .'2-:,"'"0 \l¡£..Efu.:o-C-·~ {~(\!o i Bldg, No,: 0\ City: _Bakersfield_ Zip: _93307_ Contact Phone No.: (l:Li ) ,3}:J".. Ll('1I2C> l,1{1,·u...'ÐiDate of Testing/Servicing: ¡J cl / );'1/ t..J if B. Inventory of Equipment; Tested/Certified Check the a ro riate boxes to indicate s ecific e ui ment ins ected/serviced: Tank ID: /'D 5t In-Tank Gauging Probe. ¡Model: tV\\A.i _, , o Annular Space or Vault Sensor. ; Model: h.il:µ...\-=' o Piping Sump 1 Trench Sensor( s). I Model: ¡<..ic ".....,¡"' o Fill Sump Sensor(s). : Model: tdi·'''......:''õ. o Mechanical Line Leak Detector. : Model: lAir..,. .;r;:: o Electronic Line Leak Detector. : Model: (' ..Avv\Qu \V\;'U:::;:;; i'L o Tank Overfill 1 High-Level Sensor. : Model: ~€"'U.~ç o Other s eci e ui ment e and rhodel in Section E on Pa e 2 . Tank ID: A\ '.' o In-Tank1fa"uging Probe. Model: 1M ~.1.b ._ o Annular Space or Vault Sensor. Model: I'\.\.f:: ~'" ~ o Piping Sump 1 Trench Sensor(s). Model: f\t '·.,u(i:;' o Fill Sump Sensor(s). Moðel: id"'~cJ"G- o Mechanical Line Leak Detector. Mo~el: fAl.t' ,,~ ..;-- o Electronic Line Leak Detector. Mo~el: (39,-"""" n ,..,I., ü...;':' ,.,_ o Tank Overfill/ High-Level Sensor. Mo el: \..~\.E.\£;a.J.'-:t·::" o Other s eci e ui ment e and mod I in Section E on Pa e 2). TankID: TankID: o In-Tank Gauging Probe. ! Model: W\\.o'\-b..L 0 In-Tank Gauging Probe. Model: L'\ti ~'\l.> ;, o Annular Space or Vault Sensor. I Model: Nn~....,,--. 0 Annular Space or Vault Sensor. Model: ;\1"".,->,(:;;, o Piping Sump / Trench Sensor(s). I Model: ¡"it).;,} 1,''- 0 Piping Sump / Trench Sensor(s). Model: (-'"-..1.iC-'~i'C;: o Fill Sump Sensor(s). Model: Ã/./ì..:, / .,r... 0 Fill Sump Sensor(s). Model: l-d .")".(':- o Mechanical Line Leak Detector. : Model: /'\../ù.t....,/~':$ 0 Mechanical Line Leak Detector. Model: t"\U:·,<, tì:" o Electronic Line Leak Detector. ¡ Model: e'''~M Çë~ l.:'V\l'l ¡ ~~"-t 0 Electronic Line Leak Detector. Model: () íAi '-'If'\'- \/-,\,' ,.i..-,ì~ j o Tank Overfill 1 High-Level Sensor. ¡Model: '/f?ìÆ..'lJ.JY"-- 0 Tank Overfill 1 High-Level Sensor. Model: \ O~ï==-;Þ /ztx'} ;:- o Other s eci e ui ment t e and model in Section E on Pa e 2). 0 Other (s eci e ui ment ty e and model in Section E on Pa e 2 . Dispenser ID: I Dispenser ID:L\ . . )š3 Dispenser Containment Sensor(s). I Model: \iiE,\'?oJ<r "1,\ \ \~ .IS Dispenser Containment Sensor(s). Model: \j\=x-fVU '; 1'\\ \'~') o Shear Valve(s).; 0 Shear Valve(s). o Dis enser Containment Float(s) and Chain(s). 0 Dis enser Containment Float(s) and Chain(s). Dispenser 10: :}. i Dispenser 10: :;- B Dispenser Containment Sensor(s). I Model: ( ~irx:;"..:"":) <' '\ \ \3 )is! Dispenser Containment Sensor(s). Model:\j~~LI"'J " "1. l \ ~ .0 Shear Valve(s). I 0 Shear Valve(s), o Dis enser Containment Float(s) and! Chain(s). 0 Dis enser Containment Float(s) and Chain(s). Dispenser 10: 3 : Dispenser ID: ----.:-':----_,~~. _ _' b : 7 Ji¡;I' Dispenser Containment Sensor(s). ! Model: d p\ë:C:.!l:N -( ;1 \ \3 Ii:! Dispenser Containment Sensor(s). MOdel'\"[FÚ'::.!Z,'-{".y "1 \\~ o Shear Valve(s).: 0 Shear Valve(s). ODis enser Containment Float(s) and ¢hain(s). 0 Dis enser Containment Float sand Chain(s). *Ifthe facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that1the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to this C~rtification is information (e.g. manufacturers' chec 'sts sary to verify that this information is correct and a Plot Plan showing; the layout of monitoring equipment. For an uipm t apabl of generating such reports, I have also attached a copy of the report; (checli all that apply): ~ System set- ~l histo y report Technician Name (print): \.r\A\M~ ~ ¡A,C'l(?'J"\'-I.....\ Sign ure: I Certification No.: DéJCJC.;- qOf(}n I Testing Company Name: _SunsFt Mechanical Site Address; 46] 7 Kimber A venue Bakersfield, CA. - ! I .--' 58957] - Phone No. :( _66]J _322-0660 Date of Testing/Servicing: 9-! ;7 / o~1 I Monitoring System Certification: Page 1 of 3 03/01 ~:~ D. R-esults of Testing/Servicing Software Version Installed: .\\1 ~ Com lete the followin checklist: fi'Þ Yes D No* Is the audible alann 0 erational? Yes D No* Is the visual alann 0 erational? ,¡) Yes D No* Were all sensors visually ins ected, functionall tested, and con finned 0 erational? p Yes D No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment wilJ not interfere with their pro er 0 eration? If alanns are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) 0 Sumpffrench Sensors; 0 Dispenser Containment Sensors. Did you confinn ositive shut-down due to leaks and sensor failure/disconnection? 0 Yes; 0 No. D No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no ON/A mechanical overfill prevention valve is installed), is the overfill warning alann visible and audible at the tank fill oint( s) and 0 erating roperly? r f so, at what ercent of tank ca acity does the alann trig er? c,' % Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all re lacement arts in Section E, below. Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) 0 Product; D Water. If yes, describe causes in Section E, below. l3 Yes 0 No* Was monitoring system set-u reviewed to ensure ro er settin s? Attach set u . Yes D No* Is all monitoring e ui ment 0 erational er manufacturer's s ecifications? * In Section E below, describe how and when these deficiencies were or will be corrected. DYes o No* D N/A D No* ,. N/A DYes aYes D Yes* ~ No D Yes* ~ No E. Comments: Page 2 of3 03/01 Y,- F: In- Tank Gauging / SIR Equipment: '" Check this box if tank gauging is used only for inventory control. o Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: &) Yes o No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? ~ Yes o No* Were all tank gauging probes visually inspected for damage and residue buildup? ~ Yes 0 No* Was accuracy of system product level readings tested? '9iiÞ Yes 0 No* Was accuracy of system water level readings tested? ~ Yes CJ No* Were all probes reinstalled properly? ~ Yes CJ No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): C CJ Check this box if LLDs are not installed. omplete t e 0 owmg c ec 1st: ~ Yes CJ No* For equipment start-up or annual equipment certification, was a leak simulated to verifY LLD performance? CJ N/A (Check all that apply) Simulated leak rate: ¡aJ3 g.p.h.; CJ 0.1 g.p.h ; jQ 0.2 g.p.h. ~ Yes CJ No* Were all LLDs confirmed operational and accurate within regulatory requirements? }9 Yes CJ No* Was the testing apparatus properly calibrated? CJ Yes CJ No* For mechanical LLDs, does the LLD restrict product flow if it detects a leak? CJ N/A ;IQ¡ Yes CJ No* For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? CJ N/A ¡) Yes CJ No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled o N/A or disconnected? ¡iJ. Yes CJ No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions CJ N/A or fails a test? ðb Yes CJ No* For electronic LLDs, have all accessible wiring connections been visually inspected? CJ N/A fQ Yes CJ No* Were all items on the equipment manufacturer's maintenance checklist completed? h £ 11 h kr * In the Section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: Page 3 of3 03/01 -':~ Monitoring System Certification Site Address: UST Monitoring Site Plan 2200 E. Brundage Lane Bakersfield . . . . . . 'l-:Ù . /,,-\~,. c' . \.../. . .. \~.~ ·0' ~() '·fl " , , ..~Ì¡ ~¡¡\ . '"1VJ . '-:-:;;;',1,;1). './ . . )..b~Òí~L: ': . . rn '.D¡6¡')p· " .~~ _ J. · . . . . . . ·1-0 · . . .. ~~ "~ ,¡h\1 (~t4?¡·v~1 ~. .---. '1~-, 3 . .~ ¡~-.(~/~~/:~ \~ : ~j , \ -' - . . : ~ I~J -~. . Or.?V~¡ý· ~~ : · \lJ' '" L. . .~ ' ~t . · (; G ' . -~ . '. ..~ }!Jl. · "§ \~ -t ·">("t'~#·~t < 'f\. . . ...... . . . . , .' "t , I··.... .,.. : ': J"î\·~~~:1 ~ : .. --3... '~j' ~'ï;j"\' ¿?ðp:f;.f2 .~ ,¡ : t-.v'~ü~, ' L ).~.o. _ \. . ...,....~...., . · . , , . . . . .-s;. . . . . . .~ .~~ Date map was drawn: 2-/ 17//..7 ,-:(. Instructions If you already have a diagram that shows all required information, you may include it, rather than this page, with your Monitoring System Certification, On your site plan, show the general layout of tanks and piping. Clearly identify locations of the following equipment, if installed: monitoring system control panels; sensors monitoring tank annular spaces, sumps, dispenser pans, spill containers, or other secondary containment areas; mechanical or electronic line leak detectors; and in-tank liquid level probes (if used for leak detection). In the space provided, note the date this Site Plan was prepared, Page_of_ 05/00 ,. IN-TANK SETlÌP ------ - SYSTEM SETUP - - - - - - - - - - - - SEP 17, 2004 10:55 AM T 1 :L-S DIESEL PRODUCT CODE THERMAL COEFF TANK DIAMETER TANK PROFILE FULL VOL : 1 : .000450 : 95.00 1 PT 10000 SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH . SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM WHOLESALE FUEL 2200 E BRUNDAGE LN BAKESFIELD CA 93304 SHIFT TIME 1 SHIFT TIME 2 SHIFT TIME 3 SHIFT TIME 4 11:00 PM 12:00 AM 1 : 00 AM 2:00 AM 4.0 IN. 4.0 5.0 10000 90% 9000 95% 9500 1% 100 LOW PRODUCT : 0 LEAK ALARM LIMIT: 75 SUDDEN LOSS LIMIT: 99 TANK TILT : 2.40 PROBE OFFSET 0.00 FLOAT SIZE: WATER WARNING : HIGH WATER LIMIT: MAX OR LABEL VOL: OVERFILL LIMIT : HIGH PRODUCT DELI VERY LI M IT TANK PER TST NEEDED WRN DISABLED TANK ANN TST NEEDED WRN DISABLED LINE RE-ENABLE METHOD PASS LINE TEST LINE PER TeT NEEDED WRN DISABLED LINE ANN TST NEEDED WRN DISABLED PRINT TC VOLUMES ENABLED SIPHON MANIFOLDED TANKS nt: NONE LINE MANIFOLDED TANKS TI:t: NONE LEAK MIN PERIODIC: 10% 1000 LEAK MIN ANNUAL : 10% 1000 TEMP COMPENSATION . VALUE (DEG F): 60.0 ST I CK HE I GHT OFFSETI DISABLED ' DAYLIGHT SAVING TIME ENABLED START DATE APR WEEK START TIME 2:00 AM END DATE OCT WEEK 6 SUN END TIME 2:00 AM PERIODIC TEST TYPE STANDARD , I ANNUAL TEST FAIL ALAR!"! DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY : 1 MIN PUMP THRESHOLD : 10.00% SUN SYSTEM SECURITY CODE : 000000 CUSTOM ALARM LABELS DISABLED - - -------~~~-- T 2:PRE-UNLEADED PRODUCT CODE THERMAL COEFF TANK DIAMETER TANK PROFILE FULL VOL FLOAT SIZE: WATER WARNING : HIGH WATER LIMIT: MAX OR LABEL VOL: OVERF I LL LI M IT HIGH PRODUCT DELI VERY' LI M IT ·'t.. , .~ LOW PRÖDUcf' : LEAK ALARM LIMIT: SUDDEN LOSS LIMIT: TANK TILT PROBE OFFSET : 2 : .000700 95,00 1 PT 10000 4.0 IN. 4.0 5.0 10000 90% 9000 95% 9500 1% 100 o 75 99 2.95 0.00 SIPHON MANIFOLDED TANKS TIi: NONE LINE MANIFOLDED TANKS Tft: NONE ' - LEAK MIN PERIODIC: 10% 1000 LEAK MIN ANNUAL 10% 1000 PERIODIC TEST TY'PE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY': OFF TNK TST SIPHON BREAK:OFF DELIVERY' DELAY' : 1 MIN PUMP THRESHOLD : 10.00% - - ~-~_..__. ---, -------.- T 3:CLEAR-DIESEL PRODUCT CODE THERMAL COEFF TANK DIAMETER TANK PROFILE FULL VOL : 3 : .000450 120.00 1 PT 20563 FLOAT SIZE: 4.0 IN. 4.0 5.0 20563 90% 18506 95% 19535 1% 205 LOW PRODUCT : 0 LEAK ALARM LIMIT: 75 SUDDEN LOSS LIMIT: 99 TANK TILT :- 0.50 PROBE OFFSET 0,00 WATER WARNING : HIGH WATER LIMIT: MAX OR LABEL VOL: OVERF I LL LI M IT HIGH PRODUCT DELIVERY' LIMIT SIPHON MANIFOLDED TANKS T#: NONE LINE MANIFOLDED TANKS TIi: NONE LEAK MIN PERIODIC: 10% 2056 LEAK MIN ANNUAL 10% 2056 PERIODIC TEST TY'PE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY': OFF TNK TST SIPHON BREAK:OFF DELIVERY' DELAY' : 1 MIN PUMP THRESHOLD : 10.00% -~ '-..-.--'- -- T 4:UNLEADED PRODUCT CODE THERMAL COEFF TANK DIAMETER TANK PROFILE FULL VOL FLOAT SIZE: WATER WARNING : HIGH WATER LIMIT: MAX OR LABEL VOL: OVERFILL LIMIT : HIGH PRODUCT DELIVERY LIMIT LOW PRODUCT : LEAK ALARM LIMIT: SUDDEN LOSS LIMIT: TANK TILT : PROBE OFFSET 4 : .000700 : 120.00 1 PT 20563 T 5:DYED-DIESEL PRODUCT CODE THERMAL COEFF TANK DIAMETER TANK PROFILE FULL VOL 4.0 IN. . FLOAT SIZE: WATER WARNING : HIGH WATER LIMlT-: MAX OR LABEL VOL: OVERFILL LIMI,T : HIGH PRODUCT DELI VERY LI M IT 4.0 5.0 20563 90% 18506 95% 19535 1% 205 o 75 99 0.00 0.00 LOW PRODUCT : LEAK ALARM LIMIT: SUDDEN LOSS LIMIT: TANK TILT : PROBE OFFSET SIPHON MANIFOLDED TANKS T¡:t: NONE LINE MANIFOLDED TANKS T¡:t: NONE LEAK MIN PERIODIC: LEAK MIN ANNUAL : 5 : .000450 : 120.00 1 PT 20563 4. DIN. 4.0 5.0 20563 90% 18506 95% 19535 1% 205 o 75 99 0.00 0,00 SIPHON MANIFOLDED TANKS T¡:t: NONE LINE MANIFOLDED TANKS T¡:t: NONE 10% 2056 LEAK MIN PERIODIC: 10% 2056 LEAK MIN ANNUAL: PERIODIC TEST TYPE STANDARD 10% 2056 10% 2056 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER, TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY : 1 MIN PUMP THRESHOLD : 10.00% -- ------ -- ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY : 1 MIN PUMP THRESHOLD : 10.00% - - -- --- - _._ ._u__" ".-- T 6:EPA-DIESEL PRODUCT CODE THERMAL COEFF TANK DIAMETER TANK PROFILE FULL VOL : 6 : .000450 : 120.00 1 PT 20563 T 7:EPA-2 PRODUCT CODE THERMAL COEFF TANK DIAMETER TANK PROFILE FULL VOL : 7 : .000450 : 120.00 1 PT 20563 FLOAT SIZE: WATER WARNING : HIGH WATER LIMIT: MAX OR LABEL VOL: OVERFILL LIMIT : HIGH PRODUCT DELI VERY LI M IT 4.0 IN. 4,0 5.0 20563 90% 18506 95% 19535 1% 205 o 75 99 2.00 0.00 FLOAT SIZE: WATER WARNING : HIGH WATER LIMIT: MAX OR LABEL VOL: OVERFILL LIMIT : HIGH PRODUCT DELI VERY LI M IT 4.0 IN. 4.0 5.0 20563 90% 18506 95% 19535 1% 205 o 75 99 2.00 0.00 LOW PRODUCT : LEAK ALARM LIMIT: SUDDEN LOSS LIMIT: TANK TILT : PROBE OFFSET LOW PRODUCT : LEAK ALARM LIMIT: SUDDEN LOSS LIMIT: TANK TILT : PROBE OFFSET SIPHON MANIFOLDED TANKS nt: NONE LINE MANIFOLDED TANKS T;t: NONE SIPHON MANIFOLDED TANKS Tit: NONE LINE MANIFOLDED TANKS Tit: NONE LEAK MIN PERIODIC: 10% 2056 LEAK MIN ANNUAL 10% 2056 LEAK MIN PERIODIC: 10% 2056 LEAK MIN ANNUAL 10% 2056 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY : 1 MIN PUMP THRESHOLD : 10,00% PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY : 1 MIN PUMP THRESHOLD : 10.00% - - - ------- ------ -~- - ~_. ---- ---- T 8: UU:3C-D I ESEL PRODUCT CODE THERMAL COEFF TANK DIAMETER TANK PROFILE FULL VOL : 8 : .000450 : 96.00 1 PT 12000 4.0 IN. 4.0 5.0 12000 90% 10800 95% 11400 1% 120 LOW PRODUCT : 0 LEAK ALARM LIMIT: 75 SUDDEN LOSS LIMIT: 99 TANK TILT : 5.00 PROBE OFFSET 0.00 FLOAT SIZE: WATER WARNING : HIGH WATER LIMIT: MAX OR LABEL VOL: OVERFILL LIMIT : HIGH PRODUCT DELIVERY LIMIT SIPHON MANIFOLDED TANKS nt: NONE LINE MANIFOLDED TANKS nt: NONE LEAK MIN PERIODIC: 10% 1200 LEAK MIN ANNUAL 10% 1200 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY : 1 MIN PUMP THRESHOLD : 10.00% LEAK TEST METHOD - - - - - - - - - - - - TEST MONTHLY : ALL TANK WEEK 2 SUN - START TIME: 2: 00 AM TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED LEAK TEST REPORT FORMAT NORMAL LIQUID SENSOR SETUP - - - - - - -- L 1 :DIS-PANS NORMALLY CLOSED CATEGORY : DISPENSER PAN L 2 :DIS-PANS NORMALLY CLOSED CATEGORY : DISPENSER PAN L 3:DIS-PANS TRI-STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN -.-.--..--...----- ....--~- -..-----------.- ,. OUTPUT RELAY SETUP ------ R 1 :POS-EPA TYPE: STANDARD NORMALLY OPEN IN-TANK ALARMS T 7:0VERFILL ALARM R 2:0UTSIDE ALARM TYPE: MOMENTARY NORMALLY OPEN LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ALL:WATER OUT ALARM ALL:HIGH LIQUID ALARM R 3 :PANS L 2. 3 TYPE: STANDARD NORMALLY CLOSED LIQUID SENSOR ALMS L 1: FUEL ALARM L 3:FUEL ALARM R 4:PANS 4.5.6 TYPE: ' STANDARD NORMALLY CLOSED LIQUID SENSOR ALMS L 2:FUEL ALARM RECONCILIATION SETUP - - - - - - -- AUTOMATIC DAILY CLOSING TIME: 2:00 AM PERIODIC RECONCILIATION i"10DE: MONTHU TEMP COMPENSATION STANDARD BUS SLOT FUEL METER TAN~ - - - - - - - - - - - - TANK MAP EMPTY , "\~. WHOLESALE FUEL 2200 E BRUNDAGE LN BAKESFIELD CA 93304 SEP 17. 2004 11~04 AM LEAK TEST REPORT T 2:PRE-UNLEADED PROBE SERIAL NUM 254008 WHOLESALE FUEL 2200 E BRUNDAGE LN BAKESFIELD CA 93304 SEP 17. 2004 11:03 AM LEAK TEST REPORT T 1 :L-S DIESEL PROBE SERIAL NUM 005380 TEST STARTING TIME: SEP 12. 2004 2:00 AM TEST LENGTH STRT VOLUME 2.0 HRS 558.0 GAL TEST STARTING TIME: SEP 12. 2004 2:00 AM START TEMP END TEMP 90.0 F ~O.O F TEST LENGTH = 68921',04 GH~E STRT VOLUME = TEST PERIODS 2-4 -0.00 -0.00 0.00 LEAK TEST RESULTS RATE = 0.00 GAL/HR 0.20 GAL/HR TEST INVL 0.20 GAL/HR FLAGS: LOW LEVEL TEST ERROR PERCENT VOLUME TOO LOW INVALID FUEL LEVEL ~ ~ ~ ~ ~ END ~ ~ ~ ~ ~ START TEMP = 91.2 F END TEMP = 91.2 F TEST PERIODS 2-4 0.02 0.02 0.02 LEAK TEST RESULTS RATE = 0.01 GAL/HR 0.20 GAL/HR TEST PASS ~ ~ ~ ~ ~ END ~ * ~ * * L--~- .--_._----~ ~ .. WHOLESALE FUEL 2200 E BRUNDAGE LN BAKESFIELD CA 93304 SEP 17. 2004 11 :04 AM LEAK TEST REPORT T 5:DYED-DIESEL PROBE SERIAL NUM 006005 WHOLESALE FUEL 2200 E BRUNDAGE LN BAKESFIELD CA 93304 SEP 17. 2004 11:04 AM LEAK TEST REPORT T 4:UNLEADED PROBE SERIAL NUM 006003 WHOLESALE FUEL 2200 E BRUNDAGE LN BAKESFIELD CA 93304 SEP 17. 2004 11:04 AM LEAK TEST REPORT T 3:CLEAR-DIESEL PROBE SERIAL NUM 006004 TEST STARTING TIME: SEP 12. 2004 2:00 AM TEST STARTING TIME: SEP 12. 2004 2:00 AM TEST STARTING TIME: f SEP 12. 2004 2:00 AM TEST LENGTH 2,0 HRS STRT VOLUME =14956.9 GAL TEST LENGTH 2 ,0 HR: STRT VOLUME =15230.7 GA TEST LENGTH 2.0 HRS STRT VOLUME 7563.3 GAL START TEMP END TEMP 90.7 F 90.7 F START TEMP 94.3 F END TEMP - 94.2 F TEST PERIODS 2-4 -0.00 0.12 0.17 LEAK TEST"RESULTS RATE = 0.11 GAL/HR 0.20 GAL/HR TEST INVL 0.20 GAL/HR FLAGS: RECENT DELl VERY START TEMP 94.5 F END TEMP 94.4 F TEST PERIODS 2-4 -0.08 -0,07 -0.07 LEAK TEST RESULTS RATE = -0.05 GAL/HR 0.20 GAL/HR TEST INVL 0.20 GAL/HR FLAGS: RECE NT" DEL I VERY TEST PERIODS 2-4 0.11 0.19 0.21 LEAK TEST RESULTS RATE = 0.14 GAL/HR 0.20 GAL/HR TEST INVL 0.20 GAL/HR FLAGS: RECENT DELIVERY PRODUCT LEVEL INCREASE ~ ~ ~ ~ ~ END ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ END ~ ~ ~ ~ ~ ~ * ~ * ~ END * ~ ~ ~ ~ ----^--- .. "- .~ .. --------- - . ~' y WHOLESALE FUEL 2200 E BRUNDAGE LN BAKESFIELD CA 93304 SEP 17, 2004 11:03 AM LEAK TEST REPORT T S:CLEAR DIESEL PROBE SERIAL NUM 005379 WHOLESALE FUEL 2200 E BRUNDAGE LN BAKESFIELD CA 93304 SEP 17, 2004 11:04 AM LEAK TEST REPORT T 7:EPA-2 PROBE SERIAL NUM 255709 TEST STARTING TIME: SEP 12, 2004 2:00 AM TEST STARTING TIME: SEP 12, 2004 2:00 AM TEST LENGTH STRT VOLUME 2,0 HRS 605.3 GAL TEST LENGTH STRT VOLUME 2.0 HRS 930.0 GAL START TEMP 84.3 F END TEMP 82.5 F TEST PERIODS 2-4 0.00 -0.01 -0,03 LEAK TEST RESULTS RATE = -0.02 GAL/HR 0.20 GAL/HR TEST INVL 0.20 GAL/HR FLAGS: LOW LEVEL TEST ERROR CHANGE IN TANK TEMP ZONE TEMP CHANGE TOO LARGE PERCENT VOLUME TOO LOW ~ ~ ~ ~ ~ END ~ ~ ~ ~ ~ START TEMP END TEMP 85.4 F 83,7 F TEST PERIODS 2-4 -0,04 0.05 0.06 LEAK TEST RESULTS RATE = 0.04 GAL/HR 0.20 GAL/HR TEST INVL 0.20 GAL/HR FLAGS: LOW LEVEL TEST ERROR CHANGE IN TANK TEMP ZONE TEMP CHANGE TOO LARGE PERCENT VOLUME TOO LOW ~ ~ ~ ~ ~ END ~ ~ ~ ~ ~ ^"_. . '~--'--'-----"---"-' -~--- -- - ---~ -"'-' .-- -- ~.- --_._--~~-- WHOLESALE FUEL 2200 E BRUNDAGE LN BAKESFIELD CA 93304 SEP 17, 2004 11 :04 AM LEAK TEST REPORT T 6:EPA-DIESEL PROBE SERIAL NUM 006636 JNgTl~TARTING TIME: , 2004 2: 00 Ai"1 TEST LENGTH _ STRT VOLUME; 27522'50 HRS . GAL START TEMP END TEMP 89.2 F ,89,2 F TEST PER !ODS 2-4 -0.00 -0.02 -0.03 LEAK TEST RESULTS RATE = -0.02 GAL/ 0.20 GAL/HR TEST ~~VL f6~0 GAL/HR FLAGS: LEVEL TEST ERROR ~ ~ ~ ~ ~ END ~ ~ ~ ~ * .-.-.----- ; e e ~ SWR.CB, ]anu~ry 2002 Page --L- of _~, Secondary Containment Testing Report Form ThÚ'form is intended for use by contractors performing periodic testing of UST seconda1)' CQntainm8/ t systems. Use the appropriate pages of thi.s'form to report re.wits for all çom'P0nent~· teJted. The conipletedfórm. written test procedureJ', ami printours from tests (if applicablej, shQuld be provided to the facility OWlter/opel'ator jor submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name; Faci1ity Address: Facility Contact: Date Local Agency Was Notified of Testing ; Name of L( cal Agency Inspector (if present during tesljngj: Date ofiesting: ~E.-~~I~L.O (Ì.A. q~~'1 I Phone: 2. TESTING CONTRACTOR INFORMATION Com any Name: t:" iechniciap. Conducting Test: k£ ~ Credentials: i CSLB Licensed Contractor License Type: o SWRCB Licensed Tank Tester License Number; 5~ Date Traininü Ex ires f.-2.S· Of> 6 ~Iq -ãe;, 6 . '~C!: - ßI:J¡,<) LA. I P "'4 ~ t<.1 f>t::.t' n Þ..Il)AI2..V PiP; N Go 'TAII\S~a.M Co T.!;.~r'N c.. COlUponent Pass Fail Not Repairs Component Pass F '[! Not ! Repairs Tested Made al I Tested r Made SP, LLÞ.--'..,.. r. t=A'" ,,", '"- "".-. .. í i&) 0 0 0 0 0 0 0 ~ R,,<¿ ~^ "". ..' """ I 'AIL i2 8 0 0 0 0 0 0 ........ I D~v ("l~AO ... ___, .f:ì,;) ~ 0 0 0 0 0 0 -º- e.... I ß."I.It.. PC4.!. " A co I....... . ~ 0 0 0 0 0 0 0 ('P'd R~ r......"._. 1& 0 0 0 0 0 Õ' 0 \.J I c:",., . _Box /;:;'(::>,4 k..~~ ., œ¡ 0 0 0 0 0 8 0 0 0 CJ 0 [J 0 ro, 0 ,J 0 0 0 CJ 0 r1 Q 0 ,oJ I 0 0 0 0 0 0 0 0 I 0 G 0 0 0 0 0 0 -- 0 0 0 0 0' 0 0 0 ù 0 0 0 0 0 0 0 3. SUMIHARY OF TEST RESULTS ¡[hydroStatic testing was performed, describe what was done with the water after completion of rests: RPn L B<\Jt E.ß \"'YO~OBT~"ïH-Le.Yï·e.~, Wn-H A"'~.K ~ ß....U"-O'''otof; ~IF W'A"T&O hf~ WAS 'Ptj,M~I::\ :r:uT'o 5~~e;.#:.\J..O~ 01:2..u M Þt'\t! ~I~f::\:)~.,- CERTIF1CATIO:"i OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING TlJ the best of my kn.owledge, the facts stated itl tltis documeltt are ~ccurate and ill full compliallce with legal requirements Technician's Signanu-e: --- ~~ ~ . . Däte:_ b -'¡IS ~C)l'¡ -- ~ .¡ SWRCB, January 2002 e ..,. . : ...; ~ e Page ...a... of _3- 9. SPDWUOVERF~LCONTMNMENTBOXES Facili is Not E ui ed With S ilVOverfiU Containment Boxes q SpilVOverfill Containment Boxes are Present.. but were Not Tested C Test Method Developed By: 0 SpiH Bucket Manufacturer gIndustry Stan(iard .J:~c.o C Other (Spe<!wJ 1'est Method Used: 0 Pressure 0 Vacuum o Other (Specify) iJ Professional Engineer R Hydrostatic Equipment Resolution::: oc~ ~. Spill Box # , Spill Box # 2- Spill Box # 3 Spill Box # "-I Bucket Diameter. 1'2.. .. I~ .. 'z.. .- j 1.. " Bucket Depth: , , " I 1.. .~ . z.. '. lL '. Wait time between applying pressure/vacuum/wa.ter and .' starting test: ìo ""....., JO M , "" 10 1'\0-.. ..v \0 ",,-.tV Test Start Time: '0 A".... Initial Reading (R¡): ?-.'£,'l'f " Test End Time: Final Reading (RF): >. Test Duration: " Change in Reading (RF4R¡): ()öo'!- '. PassIFail Threshold or , , ~ .OO~ ~.. + '. Criteria: ~ . ctO-r.- :!. . 002- u _ . co 'Z.. Test Result: œ Pass o Fail B l-ass o FIliI at Pass o Fail R' Pass OF~ . Comments - (include in,formation on repairs made prior (0 testing, and 1'I;commelldedfo/low-up.for failed te.sts) ~ ------- .'~ - -.,- - ,. TnTAI P . V\~ e e '"J. '. ". " SWRCB. January 2002 Page -3-. of 3- 9. SPfi.JLlOVERFILL CONTAINMENT BOXES Facili is Not B ui ed With S ilVûverfiU Conainment Boxes 0 . . SpilVOverfill Containment Boxes ~e Present, but were Not Tested C Test Method Developed By: 0 Spin Bucket Manufacturer Sij'Industry Standard .. w Professional Engineer ~A>Go ¡J C Other (Specify) 1'est Method Used: 0 Pressure 0 VaCUUlll .Jk!: Hydrostatic o Other (Specifl~ Test Equipment Used: :rkJec..\A) TS' 5T-S Equipment Resolution: 'Ž . <JO'Z- " Bucket Diameter. Bucket Depth: Wait time between applying pressure/vacuum/water and starting test: Test Start Time: Initial Reading (R¡): Test End Time: Final Reading (RF); Test Duration: Change in Reading (RF·R¡); PassIFaiJ Threshold or Criteria: Test Result: Spill Box # 5 'z. " 12 '. Spill Box # ~ /2.... /2- " Spill Box # SpiIJ Box # I 5 "", I'\J .' 9:(....5 "".1.ot. 4'·O/OS: .., I S' 1'-1 I'\) ,ðo/3 '" ,... -- . #, ~ . 002. " "!: . ðC'2- ,~ I¥' Pass' [J Fail ~Fass 0 Fail [) Pass 0 Fail o Pass OF~ Comments - (include in/ormation on repairs made prior to tesTing, and l'l::commendedfo/low-upforfailed Tests) ---- -----:, 1. - -- ----'- TnTAI P.ÇjR '£ -'~.'",.- -"'-'"'---.- GJS9v1d t-J.I lOe"ø NI ÇS8S-!; t00.Uf;U90 !,JI;;I £l:8 NI 688S"Ç 170.0(:/£l/90. Wi 80.:8 G3SS\:Id m ·tü0"0 NT ¿9b6";::: 170.0.(:/£Z.····90. WI;! £l:8 NI 1~¿66"£ 1:>0.0.V£V90 . ~~1yI :30.:8 ( 3SS~I':: ~·I I ?'":t:'· ø j"lI ..: .. I<Z 1:>130....::;.:;.·'90 l'J~- £2:8 NI 6¿91"Z 1:>ø0.Z/Sl/90. W:;! 813:8 llnS3d 1S31 ClOHS3ðHl )1!Ÿ!31 131Î31 aN3 31\.)(1 ON] 3~Hl aN3 13:îT! NI838 G31¡jl;;llS J.S31 G31è11;J1f:; 1831 l( J-8:!O 11n83ti 1831 G10\-\S3)j\-\1 )110131 l:3t¡Jï ( ~D 311;10 GN3 :1 Þ; Il (Jt,!~: l3n31 N IÐ38 G31~lv!lS lS::Jl G31(:1\;118 J.S3J. n~:1--t~:::r=: J.11l83(1 1831 G10HS3t1H1 >11:;131 13:î31 ON3 31.1;;I(! @J ]!H 1 aN3 l3(C~-; NI838 031dl;:llS 1831 ('~U)jlv¡lS lS3.~_ T.G~]-8:::0 W!;I t>l:8 lè!Od3::1 lS31. >!~ :r'; d~rJnS t-00.Z./£V90 Ø'390-lZ~: -199-': ¿8££6 ·Id....' (iï-:JI ""S':r.!3\11;;1::'! "I'n 3Ð~aNIl~8 ':3" ØØll 8131l::! ::!1t-1s::nOHfI: -O'":.......::-.....',__..!'" \ e _.,~--" ~--.-,..,,'.... G3S81;;1d t-H l00"Ø NI H'Þ8"£ tøØ,j£G/90 W\:;I £0.=6 NI ZttS"£ 1:>09l/£l/90. WI;J 0£:8 G3SSl;;Id tH Zøø"ø NI S0!0"Þ Þ00Z/SZ/90 1<1\;1 £0:6 t-H 8!W'þ t00Z/SZ/90 ~J!;J 0S:8 G3S8(;Jd NI Z00"Ø NI 99£¿"£ 1.>08Z/£Z/90 !JIyI £0:6 ~41 ¿¿£¿-£ 1.>0ø(:/£l/90 ~Jl;I 0.f;:8 1~Od3~! ~'JI;! ¿0:6 e llnS3;.>J 1831 G10H83::JHl >11;:1:::-1 13t'131 aN3 31~G <lN3 3¡~ 11 aN3 l3r!::n NI838 a31~1;I1S 1831 (]31~1yI1S ":"S31. ':::'d3-8:JO IlnS3ð 1831 a10H83~Hl ) 1;:I31 13r131 Gi'13 311;:1Q QN] 3~4 Ii GH3 13(131 N I038 (]]j):jlyl":":3 lS31 031dl;;l.1S 1S31 "{I_C:-fr: \.J 0.1 I...: _~'b' .1 ins3d 1831 C10HS3èJH1 >1\;13: 13r131 aN] 311;1(J Gi'!] 3¡~I1 aN3 13IÎT¡ N IÐ3S ()3H 1yI18 J.831 C31~I;; lS 1.831. 1~j¡l-8:JO !c·~! .....-...J~J.,¡,. )/i;I:r: dwns 70øl/Sl/90 ø998-,:Z£ -19';\- ¡ ¿8££6 "!;IJ ( 13I::fS1:I3)11;!8 "Nl 381;;1QNnd8"3 ø0.zz S13n::i ]ll;1S310HM ~.L~"'~ ~'~ OFFICE OF ENVIRONMENTAL SERVICES ~[~ ..~...¢~ I 15 Chester Ave., Bakersfield, CA (661)326-3979 INSPECTION RECORD POST CARD A F JOB SITE INSTRU~[ONS: Please call for an inspector only ~hen each group number I. ~O NOT cover work for any numbered group until all item~ in that group am si~ed offby the Pe~iuing Authority. Following these instructions will reduce the number of ~qui~d inspection visits and the~fore p~vem ~ment of additional fees. Backfill $pa~ Teal Cemification or M~ufactum M~t~ Cathodic Pmt~tion PIPING SYSTEM Piping & Raceway w/Collection Sump Co.sion Pmt~tion of Piping, Joinm. Fill Pi~ El~tfical Isolation of Piping From T~k(s) Cath~ic Pmt~tion System-Piping SECONDARY CO~AINME~, OVE~ILL PROTE~ION, tEAK DETE~ION Liner Installation - T~k(~) Liner Installation - Piping Vault With Product Compatible Sealer Level Chug** or Sen,om, Float Vent P~uct Compatible Fill Leak Detectors} for Annual Space-D,W. Monitoring Well(,ySump(s) - H20 Leak ~t~tion D~vice(,) for Vados~Gmundwater FINAL Monitodng Wells, Caps & L~ks Fill Box Lock Monitoring Requirements Typ~ Auth°fizati°n lBr Fud Drop ~¢' ~ ~)~ OFFICE OF E~'VIRON~IE~'TAL SER"ICES 1715 Chester Ave., Bakersfield, CA (661) 326-3979 POSF CARD.xF ~OB SiTE I,~STRL'~IO,~S: Please c~ll tbr an ins~tor only ~ea each gmu~ of ins~ions ~ith the iam~ ~umber am ~ady. They will mn m zonl~¢ufive o~er be~inaiag ~ith number I. O0 NOT cover work tbr any numbc~d ~up unlil all itc~ in thai ~up am si~ offby thc Pc~itting Authority. Foilowin$ these instructions will ~uce number of ~quimd inspection visils and thcm~bm prevent ~e~ment of additional ~ccs. PI PI~ SYSTEM El~tdcal I~lation of Piping From T~k(s) Cath~ic Proration System-Piping SECONDARY CO~AINME~, OVE~ILL PROTE~iON, LEAK DETE~ION Liner Installation - Tank(s) Liner Installation - Piping Vault Wilh P~uct Compatible Sealer Level Gauges or Sentra, FI~I Vent V~v~ P~uct Compatible Fill Box(~) L~ak Detectors) for Annual Space-D.W. Tank(s) Monito~ng Well(s~Sump(s) - H20 Leak ~t~ction ~vic(s) ~ot VadosdGmundwa~et FINAL Monito~n8 Walls. Caps ~ Fill 8ox Lock Monito~ng Requirements Autho~zntion tbr Fuel Drop {.~1~' 'ESALE FUEL 2, . E BRUNDAGE LN WHOLESALE FUEL BPSKESFIELD CA 2200 E BRUNDAGE LN 95504 BAKESFIELD CA SENSOR ALARM 95504 APR 23. 2004 4:10 PM L . · D I S-P~NS DISPENSER PAN APR 23. 2004 4:06 PM FUEL ALARM APR 23. 2004 3:53 PM SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL C 'TEM STATUS REPORT : SENSOR ALARM L 5 :DIS-PANS £,I~- 'qSER PAN '- I ..... SENSOR ALARM F UEs._.gqLARM ~ ~ L 2 :DIS-PANS APR 23. 2004 4:00 PM SENSOR ALARM ...... DISPENSER PAN L 1 :DIS-PANS F ; ALARM DISPENSER PAN At,~Y25. 2004 4:ii PM FUEL ALARM APR 23.. 2004 4:06 PM SENSOR ALARM L 3 :DIS-PANS DISPENSE* PAN ;~; SENSOR ALA*M FUEL ALARM ~. IS-PANS APR 23 2004 4:01 PM t4HOLESALE FUEL DISPENSER PAN 2200 E BRUNDAOE LN FUEL ALARM BAKESFIELD CA APR 23.. 2004 4:12 PM 93304 APR 23.. 2004 4:~9 PPi WHOLESALE FUEL ~TEM STATUS REPORT 2200 E BRUND~GE LN / ALL FUNCTIONS NORN~L B~KESFIELD Cg ............ [~IHOLESRLE FUEL 93304 2200 E B ~UNDRuE LN BRKESF]ELD C~ RP~ 23., 2004 4:05 PM 93304 ~ ~ APR 23, 2004 4:12 PM SYSTEM MTATLM REPORT ALL FUNCTIONS NORMAL SENSOR ALARM ..... 'STEM STATUS REPORT L 1 :DIS-PANS -~ ........... DISPENSER PAN ALL FUNCTIONS NORMAL ........... FUEL ALARM APR 23, 2004 4:09 PM --[ , SENSOR ALARM L i~¢dI S-PANS DISPENSER PAN ..... SENSOR ALARM FUEL ALARM L 2:DIS-PANS APR 23, 2004 4:05 PM SENSOR ALARM ...... DISPENSER PAN L 1 :DIS-PANS FUEL ALARM BISPENSER PAN APR 23, 2004 4:12 PM FLIEL ALARM AP~'-25, 2004 4:10 PM WHOLESALE FUEL 2200 E BRUNDAGE LN BAKESF I ELD CA 93304 APR 23, 2004 4:13 PM SYSTEM STATUS REPORT D  February 13, 2004 Mr. Charles McCan Wholesale Fuels, Inc. P.O. Box 82277 Bakersfield, CA 93380-2277 Re: Under-Dispenser Retrofit and Repair/Replace Piping for ELD Failure FIRE CHIEF R©N FRA££ Dear Mr. McCan: ADMINISTRATIVE SERVICES I was contacted by Mr. Mark Blackburn, at your request, to fax you the code requirements 2101 "H" Street for under dispenser containment (UDC). Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 I am enclosing this in your fax and hard copying you. It was also conveyed to me that you were not aware of the UDC requirements. This is unacceptable. I have pulled nine (9) SUPPRESSION SERVICES letters (there are a total of 18) which were sent starting in January of 2001. I do not have 2101 "H" Street time to go through all the files and puli the remaining letters, you of course have access to Bakersfield. CA 93301 VOICE (661) 326-3941 your files and may at anytime review them. FAX (661) 395-1349 Because of the failed enhanced leak detection test, it was assumed that the scope of repairs PREVENTION SERVICES included dispenser pans. However, according to Mr. Mark Blackburn that wasn't the case. FIRE SAFETY SERVICES. ENVIRONMENTAL SERV$CES 1715 Chester Ave. Bakersfield, CA 93301 This office has tried to extend you every courtesy with regard to delaying enforcement VOICE (661)326-3979 because of all the work Jaco is doing in the city. FAX (6611 326-0576 PUBLIC EDUCATION Everyone else in the city had to pull permits by 12-31-03 to stay operational. Suffice it to 1715 Chester Ave. say, my letter of January 22, 2004 (copy enclosed) requires you to have a work plan and Bakersfield, CA 93301 permit submitted by February 22, 2004. Since this is on a Sunday, I will allow it to be VOICE (661) 326-3696 FAX (661) 326-0576 submitted on Monday, February 23, 2004. FIRE INVESTIGATION If it is not received, this office will be forced to "Red Tag" your underground storage tanks 1715 ChesterAve. and will require you to take them out of service. One more point, we have no other bulk Bakersfield, CA 93301 VOICE (661) 326-3951 sites that are in the city's jurisdiction that has underground storage tanks. FAX (661) 326-0576 So that we can avoid any further confusion, I would suggest that if you have any additional TRAINING DIVISION questions that you contact me personally at 661-326-3190. 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 Sincerely yours, FAX (661) 399-5763 Steve Underwood, Fire Inspector/Petroleum SU/db Enclosures .:,~-~~. J~nuary 2'2. 2004 Mr. Charles McCan Wholesale Fuels, [nc. P.O. Box 82277 Bakersfield, CA 93380-2277 ': Re: Failed Enhanced Leak Detection of Wholesale Fuels Located at 2200 E. Brundage Lane, Bakersfield, CA ADMINISTRATIVE SERVICES 210~ "H' Stree[ 8aker$fielO, CA 93301 NOTICE OF VIOLATION VOICE (66~) 326-3941 FAX (661)395-1349 AND SCHEDULE FOR COMPLIANCE SUPPRESSION SERVICES 2101 "H' Street Dear Mr. McCan: Oakerslield. CA 93301 VOICE (661) 326-3941 VAX (66,)395d349 As you are aware, your underground storage system failed the Enhanced PREVENTION SERVtCES Leak Detection Testing. As per code you are required to repair/replace the ~,.~ ~.~,~ ~,~,~,.,...o.~.,.~,,.~. underground piping system. (Per Title 23, California Code of Regulations) 1715 Chester Ave. Bakersfield. CA 93301 VOICE {661) 320-3979 Therefore, prior to February 22, 2004 you must submit a work plan and FAX (66~) 326-0576 permit. You will then have 90 days (May 22, 2004) to complete the re-pipe PUBUc EoucA'no. of your facility. 1715 Chester Ave. Baker$1ield. CA 93301 VOICE (661) 326-3696 Should you have any questions, please feel free to contact me at FAX {661) 326-0576 661-326-3190. FIRE INVESTIGATION 1715 Chester Ave, Bakerslield. CA 93301 Sincerely yours, VOICE (661) 326-3951 FAX (661) 326-0576 Ralph E. Huey TRAINING DIVISION Director of Prevention Services 5642 Victor Ave. Bakersfield. CA 93308 i~ FAX (661) 399-5763 By: Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/db Cal. Code Regs. Title 23, Division 3, Chapter 16, Underground Tank Regulations (I) Owners or Operators of a UST system shall have thc system fitted with under-dispenser containment, or an approved under-dispenser spill containment or control system according to the following schedule: (A) At thc time of installation for systcms installed after January i, 3000. (B) By July 1,2001, for systems installed after .July I, 1987 that are located within 1,000 feet ora public drinking water well, as identified pursuant to the state Geographic Information System mapping database. (C) By December 31,2003, for systems not subject to subsection 2636(h)(1 )(A) or (B). (2) Under-dispenser containment shall be designed, constructed, installed, and monitored in accodance with section 2631, 2636(c)(2), 2636(e), and 2636(I'). (3) A manufacturer of an under-dispenser spill containment or control system may apply to the Division of Clean Water Programs Underground Storage Tank Proem Manager for approval of the system. Owners or operators shall not install an under-dispenser spill containment or control system that has not been approved. (A) Applications for approval shall be submitted in writing and include the following: (i) A description of the proposed system. (ii) Clear and convincing evidence that the system will protect the soil and beneficial uses of the waters of the state from unauthorized releases. (B) The Program Manager shall review the application to determine if the proposed system adequately protects the soil and beneficial uses of groundwater before determining whether to approve the proposed system. (C) The Program Manager may modify or revoke a previously issued approval if it finds that, based on new evidence, the approved system does not adequately protect the soil and beneficial uses of groundwater from unauthorized releases. Authority: Sections 25299.3 and 25299.7, Health and Safety Code. Reference: Sections 25281, 25284.1 25291 and 25299, Health and Safety Code; and 40 CFR 280.20 and 280.40-280.45. § 2636.1. Final Division Decisions Regarding Under-Dispenser Containment or Control Systems. (a) A manufacturer of an under-dispenser spill containment or control system who disagrees with a determination by the Program Manager not to approve the manufacturer's system under section 2636(h)(3)(B) or to modify or revoke a previously issued approval of the manufacturer's system under section 2636(h)(3)(C) may ask for review by the Division Chief. (b) An appeal to the Division Chief must be in writing and must be accompanied by all material that the manufacturer wishes to be considered by the Division Chief, and by the Board in any subsequent review by the Board. The appeal must contain an explanation why the manufacturer believes thc Program Manager's determination is erroneous, inappropriate, or improper. (c) The Division Chief shall render a Final Division Decision within 30 days of receipt of the appeal. A Final Division Decision is final and conclusive unless the manufacturer files a petition for review with the Board that is received by the Board within 30 days fi.om the date of the Final Division Decision. (d) The Division Chief may at any time, on the Division Chiefs own motion, issue a Final Division Decision. Authority: Sections 25299.3 and 25299.7, Health and Safety Code. Reference: Section 25284.1, Health and Safety Code. § 2636.2. Petition for Board Review Regarding Under-Dispenser Spill Containment or Control Systems. la/A manufacturer ma> petition the Board for review ora Final Division Decision. (bi A petition for Board review shall contain the following: I$ 2001' CALIFORNIA FIRE COOE 204 206 CORROSIYE LIQUID is a liquid which, when in contact with DIP 'E.t.N K is a tank. ,,'at or cont:t.,.cr ,>r' flammable or combus- living tissue, will cause destruction or irreversible alteration of tiblc liquid in which articles or materials are immersed for the pur- suer tissue by chemmal action. Examples include acidic, alkaline pose o.c coating, finish,rig, treating or similar processes. or caustic materials. DISPENSING is thc pounng ~r :ran:~r'cmng ora mater/al from COVERED MALL BL~I. DING is a single building enclosing a container, tank or similar vessel whereby vapors, dusts, fumes, a number of tenants and occupancies such as retail stores, drinking mi'~rs (~r gases could be liberated to thc atmosphere. and dining establishments, entertainment and amusement hcili- ~ DISPERSAL AREA, SAFE, is an area which will accommo- ties. offices, and other similar uses wherein two or more tenants ~ date a number of persons equal to the total ,:apacity of the stand have a main entrance into the mall. ~ and building which it serves such that a person within the z"ez v..!!! CRUDE PETROLEUM is a hydrocarbon mixture that has a not be closer than 50 feet ( 15 24{) mm) from the stand or bu!lding. flash point below 150°F (65.6°C) and which has not been pro- Dispersal area capacitv, shall be determined "'"_.. allowing_ 3 square cessed in a refine~', feet (0.28 m2) of net clear area per eerson. CRYOGENIC FLLrlD is a fluid that has a normal boiling point DISTILLERY is a plant or a portion of a plant where liquids below -150°F (-10I. l°C). produced by fermentation are concentrated and where the concen- trated products are also allowed to be mixed, stored or packaged. CRYOGENIC VESSEL is a pressure vessel, low-pressure tank or atmospheric tank designed to contain a cryogenic fluid on DOT is the United States Department of Transportation. which venting, insulation, refrigeration or a combination of these DRY CLEANING is the process of removing dirt, grease. is used in order to maintain the operating pressure wit,,in the de- paints and other stains from wearing apparel, textiles, fabrics, rags sign pressure and the contents in a liquid phase, or other material by the use of nonaqueous liquid solvents. It in- CURTAIN BOARD is a structure arranged to limit the spread eludes the process of dyeing clothes or other fabrics or textiles in a of smoke and heat along the ceiling. Curtain boards are sometimes solution of dye colors and nonaqueous liquid solvents. referred to as draft curtains. DUST. See definition of COMBUSTll3LE DUST. CUT-OFF STORAGE is indoor storage which is separated DWELLING is any building or portion thereof which contains from other building areas by not less than a two-hour tn'e-resistive not more than two dwelling units. occupancy separation. DWELLING UNIT is any building or portion thereof which CYLINDER is a pressure vessel designed for pressures higher contains living facilities, including provisions for sleeping, eat- than 40 psia (275.6 kPa) and having a circular cross section. It does lng, cooking and sanitation as required by the Building Code, for not include a portable tank, multiunit tank car tank, cargo tank or not more than one family, or a congregate residence of 10 or less tank car. persons. SECTION 206 ~ E SECTION 205 ~ D EARLY SUPPRESSION FAST-RESPONSE (ESFR) DEA is the Drug Enforcement Administration of the United SPRLNKLER is a sprinkler listed for early suppression fast-re- States Department of Justice. sponse performance. DEFLAGRATION is an exothermic reaction, such as the ex- ELECTRIC BLASTING CAP is a detonator which consists tremely rapid oxidation of a combustible dust or flammable vapor of a shell closed at one end. The other end contains electric wires in air, in which the reaction progresses through the unburned ma- which have been sealed into the shell. It contains a charge of deto- terial at a rate less than the velocity of sound. A deflagration can nating compound which is ign/ted or initiated by applying electric have an explosive effect, current to the wires protruding from the detonator. DESIGN PRESSURE is the maximum gage pressure that a ELECTRICAL CODE is the Electrical Code adopted by this pressure vessel, device, component or system is designed to with- jurisdiction. See the National Electrical Code. promulgated by stand safely under the temperature and conditions of use expected, the National Fire Protection Association. DESIGNATED LANDLNG AREA is the area over which ae- ELECTRICAL FIRLNG UNIT is the source of electrical cur- rial shells are fired and into which debris and malfunctioning aeri- rent used to ignite electric matches. Generally. the firing unit will al shells can fall. have switches to control the routing of the current to various fire- work items and will have a test circuit and warning indicators. DETACHED STORAGE is storage in a separate building or in an outside area located away from all structures. ELECTROSTATIC FLUIDIZED BED is a container hold- ing powder coating material which is aerated from below so as to DETONATING CORD is a flexible cord containing a center form an air-supported expanded cloud of such material which is core of high explosives and used to initiate other explosives. Ex- electrically charged with a charge opposite to the charge of the ob- amples of brand names of detonating cord include "A" Cord, De- ject to be coated. Such object is transported through the container tacord, E-Cord, Primacord, Primaline, Primex and Scotch-Cord. immediately above the charged and aerated materials in order to DETONATION is an exothermic reaction characterized by the be coated. presence of a shock wave in a material which establishes and EMERGENCY ALARM SYSTEM is a system to provide in- maintains the reaction. The reaction zone progresses through the dication and warning of emergency situations involving hazard- material at a rate greater than the velocity of sound. The principal ous materials and summon appropriate aid. heating mechanism is one of shock compression. Detonations ENCAPSULATED is a method of packaging consisting of have an explosive effect, a plastic sheet completely enclosing the sides and top of a pallet DETONATOR is a component, such as a blasting cap or an load. The term encapsulated docs not apply to banding or individ- electric blasting cap, in an explosive train which is capable of initi- ual plastic-enclosed items inside a large nonplastic-enclosed con- ating detonation in a subsequent high explosive component, tainer. 1-15 CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3rd Floor, Bakersfield, CA 93301 FACILITY NAME 1_,;3~0~t3,lt_ ~Oe_~6 INSPECTION DATE Section 2: Underground Storage Tanks Program ~l Routine ~l Combined [~l Joint Agency ~l Multi-Agency ~l Complaint [~l Re-inspection Type of Tank 5td~ C-C-,i:>, ~ Number of Tanks (a Type of Monitoring flrT'fo Type of Piping _e31,[/-.S OPERATION C V COMMENTS Proper tank data on file k.~ Proper owner/operator data on file Permit tees current ~' Certification of Financial Responsibility Monitoring record adequate and current k..,' Maintenance records adequate and current Failure to correct prior UST violations Has there been an unauthorized release? Yes No Section 3: Aboveground Storage Tanks Program TANK SIZE(S). AGGREGATE CAPACITY Type of Tank Number of Tanks OPERATION Y N COMMENTS SPCC available SPCC on file with OES Adequate secondary protection Proper'tank placarding/labeling Is tank used to dispense MVF? If yes, Does tank have overfill/overspill protection? C=C°mpliance ,4 V=Violation Y=Yes N=NO Inspector: Office of Environmental Services (805) 326-3979 ~13~Js~ess' Site Responsible Party White - Env. Svcs. Pink - Business Copy ,. T 4: UNLEADED VOLUME = 13231] GALS ULLAGE = 7333 GALS 90% ULLAGE= 5276 GALE; TC VC, LUME = 13214 GaLS HEIGHT = 73,63 INCHES [,IHOLESaLE FUEL ~ATER = 0,00 INCHES 2200 E BRUN~A.,E LN - ' , ~,.~ TEMP = R1 6 DEC F BA~(E~FIELD CA 93304 T~ ,DYED DIESEL V~IE = 10658 C~ALS JaN 1 ~,. 2004 1:44 PM ULLAGE = 9905 GALS 90% tILLaGE= 784~: GaLS TC VOLLIME = 10646 G&LS ~ HEIGHT = 61.72 INCHES ~(STEM ST~TLIS REPORT klaTER = 0.00 INCHES -~- - -. ....... TEMP = 62.4 DEG F ~LL FUNCTIONS NORNaL INVENTORY REPORT T 6:EP~ DIESEL ~ VOLUME = 7848 G~LS ULLAGE = 12715 GaLS 90% ULLAGE= 10658 G~LS T 1 :L-S DIESEL ~ TO VOLUME = 7824 GaLS VOLUME = 981 GaLS ULLAGE 9019 GaLS ~ HEIGHT = 48.78 INCHES 903~< LILLR,SE~ ~ ~RTER = 0 00 INCHES 801 ~ G~LS , ' TC VOLUME = 9va TEMP = 66 6 DEG F HEIGHT = 14.66 INCHES ~ I~RTER = 0.00 INCHES T 7:EPA 2 TEMP =' 66.4 DEG F VOLUME = 3910 GaLS ULLAGE = 16652 GaLS T ~ q"'"- ULLAGE= 14596 G~LS ~ :PREM UNLEADED - ~ .~OLUME = 3932 GaLS VOLUME = 5054 G~LS H~HT 29.42 INCHES ULLAGE - 4946 GaLS t.~I~TER = 0.88 INCHES 90~ LILL&GE~ 3946 GaLS TC VOLUME = 5034 G~LS TEMP = 47.S DEG F HEIGHT = 47.90 INCHES tO~?~R = 0.00 INCHES T 8:U.L.S.C DIESEL T{~ = 65.1 DEG F VOLUME = 3410 GaL8 tILLAGE = 8590 GaLS T 3:CLEaR DIESEL 90~a ULLAGE= 7~90 GaLS ¥OLUME = 19nc, o GaLS TC VOLUME = ~430 gaf. S ...... HEIGHT = S1.~9 INCHES ULLAGE - 8541 G~LS W~TER = 0 00 INCHES 90~¢ ULLa(SE~ 6484 GaLS ' TC VOLLIME = 1~009 GaLS TEMP = 46.6 DEG F HEIGHT = 68.00 INCHES t,IaTER = 0.00 INCHES ~ ~ ~ ~ ~ END ~ ~: ~ ~ ~ TEPIP = 62.3 DEC F "0 /Es/O! 07:45 ~'$61.' 326 05?6 MONITORING SYSTEM CERTIFICATION F~r O$~ By All Juri~dicno,u ~idtin tt~¢ Stat.¢ af A.thortty Cited: Chapter ~, 7. Health u,d S~ty Code: Chapter 14, Oiviaion J. This 23, Cui~btniu C~ i~ (~rm must ~ u~d to d~um~nc testl~ and s~icin~ at' m~ni~oring ~quipmem. A sc~a~m ~oni~carion oe m~n ~n~ b~ orooar-~ A .~pnimrin~ ~ystg~ canal ~ ~y ;hs (o~hnician who podocm~ ;he wo~. A ;opy of this (erin mu~; ~0 provided ~o ~h= t~k ~] General Information ' · "'~ Inventory of Equipment ~--eete¢Certifled · ~k ~: ~ ..._ '~.k ~: ~,~- , ........... ~nul~ S~ or Vnuk Sons~, Modal: ~ ~ul~ 8~ or Vauh ~nsor, qplng Sump / Trench ~enso~s). Mod61: ~ Hptn~$u~./~ehSen~O. ~lcc~nic Line ~k Dmsotot, Me.I: -~ ~,%L~ ~ ~oc~onic Line ~ D~eome, Model: ?nnk O~fill i Hilh-~v~l SoMor, Me,al:: 0 T~ Ove~tl I High-Le~l $es~. M~cl: ,, )t~ (s~c[fy.~ui~ant t~o ~d ,~del in 8~rion E On P~o 2), .9.0~ (s~cffy ~uipm~t.t~ ~d m~el in S~don E kw: ~ -'- ra~ ~ ~.~ ........ ~O]~ SaKe or VoUlC S~naot, Model: ~ ~nul~ ~p~e 0r Vault ~dn~at, Model: : aipin; Sump t T~Ac~ Send,si. , Model: O Piping. Sump I Trench Sensor(s). Model:, 51gothic Ling ~ ~tgcior. Modal: ffmmt '~,~ ~ ~c~onJ~ Line ~ Detecwr. M~I: 'a0k O~ll / High-~vel 3~aor. 'Model: O Tank eye. Il I High. Level Sensor. Model; )ls~nseeCon[~nm~t S~n~or(s). M~el: ~ Dispenser Concalmnent Sensor(s), Modch qs~nserContalnm~nt ~o~c(s) and Ch~n(~), : ~ Dt~penserCont~n~n~ ~oac(s) ~d Chain(s). , tia~n~ctContainment ~nso~s). Mo~oI: 0 Dis~ns~rCon~nmem Sen~O. Model:... haar V~v~I~ 0 Sheaf dspe~rCop~aimn~m ~oal(f) arid Chalks~, . .... . _ 0 DJspenscr, Con[aiamgnt Float(I) and Chainf~). ~af Valvds). ~ Sheur VALv¢Cs). ~Anser CantOnment FLea. A). AAa ~ain(s}. ,,,. , , _ ~ ,Ois~nser,,Con¢~fl~nt. ~loat(s),...,. and Ck~aiS),.: ."It ~e f~ili~ aontlins more tnnk~ ~ d~s~nsers. ~py ~i~ fa~, Include infamm[iOn for every I~ ~ dispona~ al the fa~i]i[y. C, Certification · i ct~ that the ~lpment Iden~ in t~s d0~flt wu I~g~t~so~tced ~ n~o~n~ with the m~ufac~en' corr~t and. Plot PI~ ihowlng the layout of mo~to~ng ~C For any e~e.~ ~able of tone.ting such rcpor.t ] haw also' attached n copy or the rep~; (~heck~ that a~ply): ~ystem sci-up ' ~nlarm history report To ~nician N~ (aria0: -,,, - ~ ~- ' ': -- M< ,i[ocing System Certll?eaHon ~0 Bg~d J_BSNRS ~LO9~CT99 ZO:PT P00~/gI/T0 07;45 '~B6.1.. 3P. 8 0578 BFD [.IAZ /,IAT DTV · ; ~}00.2 MONITORING SYSTEM CERTIFICATION ' ~'ar U~e By All J4~H#dictton~ Wlrhitt thc State o/Cuti[¢)ntict Attthur#y Cited: Chupter ~. Z Heall~ a~d Sufe~' Cod~: C~ter 10, Oivisi~n each m~pitoring ~Vs~cm control p~ by the mchnlcian who performs ibc wark, A copy oE ~his t~rm mu~( be p~vi~ad ~o th~ ~ank ~tm owne~/operacor. ~e owner/opera,or must submit a copy or [his Ib~ m ~he I~a[ a$cncy r~l~L~nS UST systems within 30 General [flf0rmation Xnvento~ of Equipment Teate~Cerufied , 'rank ~n-T~k Gau~ng Pro~, M~el: ~ R~'-~! .., e In.T~nk Gauging Probe. Mod~l: ~.g- m~& I : Sump 1 T~neh Sm~oA~). Model: ~ Pipin$ Sump./T~aoh $en~o~s). M~el: Sump ~enlor(s). M~ei: ~ Fill ~ump $cnsoNs). M~el: Line L~ ~ttctor, M~el: - ---.. ~ M~h~ical Line Leak D~ctor. Line LG~ O~(~. Modol:~~ ~~ ~ ~leo~nla Line ~ Demmot. Med~J: iHigh.~&lSenso~. Modtl:L . ._ __ O T~kO~lll~$R-LevelSens~. M~cI: model in Secdon in Sec~n E on t Sum~ I ~ench $cn~a~). , M~e]: ~ Piping. Sump I ~nch ScnaeffS), M~cl: $=naorO). M~eI: __ ~ Fill Su~ ~nsoc(s}. Modeh ~ ~tecmr, Model: Q M~chaniC~ LiM LeR ~ctor. bt~tl: ModeJ: Q ~]~e~onic ~in¢ ~ Dct~¢tor, ~od~: I H~.~vct Sensor, M~eI: ~ T~Ove~ll / High-Level S¢flsor. Model: : ~d model in ~ctlon E on model in $~ti0n E on ~ Diapen{et Cont~nm~nt and $eMot(*). Modeh ~ Dhp~n~=e Con~ain~nt ~), Model: ~heir Vaive~}, ~ 5aeur V~veG), . {~[s~flset Contuinm~n[ ~oar(m) ~d Chain(i) ..... J 0 Dii~n~cr,~nt~nmem Float(~ and Chain(s). ~[~lspenscrContmlnmcn~Sun~o~s]. Modull .... [ ~ DJ{pcnscrCon[~n~n[$cnmor(s). Mad~l: ,=, e0r~et and a Pl~ Pl~ showing the layout of mo~to~flg e~p~nt. For any pqdp~nt ~pabJe attached a copy or the tappet (check nl~t~t ~plyJ~ ~Sy~tem ~[.up ~Alarm ~sto~ report , ' Page t at 3 O~lOt itorln~ System Certi~ca~ion E0 BD~d i3SNnS ~Z09~g]99 iO:~ P00~/PZ/]B o.9/2U/01 07:48 q~661 32B 0576 BFD }AZ )IAT DIV : ~OOS Results of Tes;in~Serviciag Y*~ 0 No~ [~ ~e visuai al~ ope~tion~i~,, Y~s '~ 'No* lff al~s ~= r~Za~d m n cemom monitoring S~ti~, is ~'1' eomm~icat[ona equipment (e.g, ~odem~ ~ N/A ope~atlonal~ Y~s 0 NO* ~or prc~suriz=d' plpt.~ systems, doc~ C~ ~ur~tn~ nutomadcally ~huc'~own ir ~ piping ~onda~ conrain~ ~ N/A ~nlCorin3 sya~m d~cc~ a leak. ~aila to o~rate, or is elee~tcall~ dt~onn=ct~d? ;r'yes: w~ich sansora ini~iat~ ~oatavo ,Sh~own? (Chect alt t~t D~d go? ~on~rm po~leiv~ s~?t-do~ due to ]E~ ~d 9eq~r r~lu~/dlscpnnoctioO? ~Y~s; ,O ~o. Ye~' O N0* For ~nk systeme ~at utitize ~e ~nit~ng s~tem as O N/A mechani~l aviall g~vemion valve i~ instaUed), la ~ o~11 ~ing ~ visi~l~ ~d audible nt the' tank fill ~int(s) an~ o~raci~g p~ly? ~Yes* Q N0 Was ~y monitoring equipment replied? and/isc che..~aaufa~tv~t n~o and ~el f~r ~ ~placem~nt pros in ~e,ation E, b~tow. _ .................. Yo~* ~ No Was liquid found i~iaa any s~cond~ cont~nment Produce; ~ Wa~r. If 7~, deacriO~ ca~ej iff ~lign ~, ~elow. _~_.y~ Q No* Was monim~ ~yst~ ~t-up mv~v~ ~o eautr pro~ ,settles? At,ta~ s~t up mpons,-if applicabl~ Yc~ O No~ Z~ att monimrin~uipmant opcra~on~t Seedon · below, d~c~be how and when thee ~eiend~ w~e or ~U be cor~ectcd, ~ 3~d J. BSNRS ~Log~cT99 LO:bT POO~/gT/TO This ~cction must be completed if in-rank gauging equipment is used to perform leak detection monico~ng. O No* ~ all ~nput wiri~..~efl inserted ~or proper ent~ and.~r~fl~tion,_., . Y~ ['~ ~- O NO' Wcm ~1 C~ gauging p~ ¥i~ual[7 l~pec~ ror.damag~ ~d ~id~ buildup? ~Yes O.. ~o* W~re ~11 i~ema o~ ~he equip~nt manufactu~r's ~in~enance e~e~li~c * ~n the ~e~on ~, ~low,descdbe bew'a~d when th~e d~cl~Hea were et wlU be cor~ted. G, Line L~k Dete~o~ CLLD): O C~k chis box i~LL~ ~ro not in,tailed. Corn }le~ ~e fo~owln~ checMlst: ~ Yes ~ No* F~ equipmem st~-up or annu~ equipment c~ifiosdon, ~a · leek stm~ta~d ~ v=~ ~ p~fo~ ~ N/A (Che~a#lhat~pl~2) ~imulat~teakrat~;~lg.p,h.: O0.1g.p.h; Q0.ng.p.h. ~ Y~ O No' Were all L~s conflmmd ~e~tioaal ~ ~cua,e wk~n mgulato~ requirement ..... ~ Yes ~' No· Was ~e tes~ap~acua pro~ly calibreS? ..... O ~es . ~ N~L For meChaniCaL LLDa, does t~e ~ ~det ~roduer Row i~it de~c~ a ta~? .......... ~ Y~ O No' For c[~c~i~'~s, does ~o LUPine aui0~calty abut 6ff if tho I.-L~ d~mc~ a ~ Yes 0 No* ~r ol~c~onlo LLDs, doe~'~g~uto~Rcally ~hut o~ if say po~'~of ~o ~ttogng s~s~m i~ disable~ ~ N/A ordisco~e~ted? '~ Y~s O No* For ~tgc~nio ~Ds, dona cbc ~urbine aummi~c~ly shut offif ~y p0~ion of th6 monkorlng sys~m ~l[unctions ~ N/A or [oitsa tes~? ~ Yes O No* For'eio~onlc L~s, have ~1[ u~e~sibl~ wiri~ ~onnocdons b~n 'visually inkp~red? '-- ~es O N~ Were all items ~n th~ eq~lpmon~ m~nu~a=rur~r's ~in~ce cbeokti~r e~plo~d? · ' .... In the Sec~on H, below, d~e~be how and wbe~ ~e de~clenci~ ws~ or will be H. Co~enu: S0 BD~d .L3SNFIS ~;/_09~;gT99 /_0 :PT POO:/gT/lO TRACER TIGHT® TEST RESULTS ot Gl q & siGNED 10/15/2003 '[*q ¢..o O'el' Shirley Environmental LLC Job No: 860289 1928 Tyler Avenue, Suite K Wholesale Fuels South E1 Monte, CA 91733 2200 E. Bmndage Lane Bakersfield, CA 93308 SYSTEM STATUS SYSTEM# PRODUCT SIZE TRACER TRACER DETECTED 1N BACKFILL? Tank I L-S Diesel 10,000 A YES Tank 2 Prem. Unlead 10,000 W YES Tank 3 Clear Diesel 20,000 R YES Tank 4 87 Unleaded 20,000 A YES Tank 5 Dyed Diesel 20,000 W YES Tank 6 EPA Diesel 20,000 R YES Soil permeability is greater than 89.1 darcys. GROUND WATER AND PRODUCT INFO AT INOCULATION AT SAMPLING DEPTH FROM GRADE 09/24/03 10/03/03 WATER TANK TANK TABLE BOTTOM TOP SYSTEM# H20 PROD H20 PROD (in) (in) (in) (in) (in) (in) (in) Tank 1 0.00 0.00 0.00 58.00 >144 153 57 Tank 2 0.00 0.00 0.00 37.00 >144 153 57 Tank 3 0.00 0.00 0.00 48.00 > 144 162 66 Tank 4 0.00 0.00 0.00 72.00 > 144 162 66 Tank 5 0.00 0.00 0.00 49.00 > 144 162 66 Tank 6 0.00 0.00 0.00 46.00 > 144 162 66 SITE COMMENTS Backfill in tank pit and piping trench consists of ¼ to 72 inch sand. Ground cover over tanks is concrete and a mixture of rocks and dirt. TEST EVENTS INSTALLATION INOCULATION SAMPLING ANALYSIS 09/24/03 09/24/03 10/03/03 10/09/03 FILL RISER- SPILL BUCKET TEST TANK# PASS/FAIL Tank 1 Pass Tank 2 Pass Tank 3 Pass Tank 4 Pass Tank 5 Pass Tank 6 Pass ! declare under penalty of perjury that I am a licensed tank tester in the State of California and that the information contained in this report is true and correct to the best of n3y kno~v~ej!~ge. Install/Inoculate ~/~///~?~ CA Lic. No:~' '~Q~ Si~ature ~~A~~~ Date Sampler~OOt ~/¢'d - CALic. No:~-I~ Si~atur~~ ~ Date TRC Analys~Ore,~.~,,~c CA nic. No: q~--J~0 Si~atur~.~ ~, ~1~,~ Date Test Comments General Tanks 1 through 6 are single walled steel. Product distribution lines are single walled fiberglass. Vent and vapor recovery lines are single walled fiberglass. Tank 1 Significant levels of Tracer A detected in backfill. Most likely source, in area of the fill / vapor recovery on tank 1. Tank 2 Significant levels o£ Tracer W detected in backfill. Most likely source, in area of the sump on tank 2. Normally tanks share the same vapor recovery piping, which can serve as a common source. Tank 3 Very Iow levels of Tracer R detected in backfill. Most likely source, in area o£ the sump on tank 3. Tank 4 Significant levels o£ Tracer A detected in backfill. Most likely source, in area of the fill / vapor recovery and the sump on tank 4. Normally tanks share the same vapor recovery piping, which can serve as a common source. Tank 5 Significant levels of Tracer W detected in backfill. Most likely source, in area of the fill / vapor recovery on tank 5. Tank 6 Very low levels of Tracer R detected in backfill. Most likely source, in area of the fill / vapor recovery and the sump on tank 6. SITE INFORMATION FORM I I Inoculation T..~o~ TracerTight ® ] [O.~ I State Technician : ~0]Oe¥~- ~Ot. . ID ~: ~cense ~ : Tracer Job ~ : ~0~TechnicianSamplins . ~ ~ ~~TraoerTi~h~~n ~: * II~ StateLicense ~ : Site ~ Name : ~~~ Precision Test ~ LeakDelineation ~ / /~ Depth to ground water in tank pit Initial Test ~ All'Water Ingress ~ Inoculation date : ~ ~ 00~ at inoculation/initial visit (in inches): in. ~ (see box at right) / / Depth to ground.water in tank pit nual Test '~ Monthly Monitoring ~ Sampling date : iO ~ ~S at sampling/second visit (in inches): ~[~q in. Retest ~ ~ ~ To be used for ALL Water Ingress Tes[s Result Verification ~ ~ Maximum Sample Vacuum Tank(s) were constantly & completely submerged in ground water for the ~esidential Tank(s) ~ (Highest probe Vacuum on site) ~ in Hg duration of the test ? YES N0 ~ ~ ~ ~ At inoculation At sampling ~ . Tank No. Produc~ o-, ~ Volume · ~ ~ ~ o ~ ~ ~ ' ~e ~ ~ ~ ~ ~.~ in tank level in tank level ~ ~ ~ ~ z:; ~ (in gallons) ~ -" ~ ~ ~ :in inches) (in inches; (in inehe. (in inches' ~ ~ ~ ~ ~ . , "° ~8 NO ~ NO ~S NO ~S NO ~ NO ~ NO Comments · Pmxair Services, Inc.. 3755 N. Business Center Drive, Tucson, AZ 85705 (520) 888-l~,00 Job#= ~O =.e:~o~-o_~ CHAI'N OF CUSTODY RECORD Ps0el ,/// / LAB U.e On~ Ch~ One Probe(s) Dep~(ff) Da~ ~me Rema~ Rel~qul~ B~ (Slgnatur~ate) ~b Rellnqulsh~ By: (SIg~u~ate) ~ % ~mum ~mp V.~ 0n Hg) ~ D.~ S,eet with ~C I~ ~ (~lg~a~r~a~) ~b Rellnqulsh~ B~ (~lg~lu~) Rema~: ~ Two Dn~ Sh~ (~e w~h ~HC & ~e without) PART ~SF01. Rev.~ 0~20~ ~ITE - R~m ~th ~1~ ~ I~ ~, PINK - ~n~s ~py ~ /~P~R. Praxair Services, Inc., 3755 N. Business Center Drive, Tucson, AZ 85705 (520) 888-9400 oate.~tO--~'O_~ CHAIN OF CUSTODY RECORD P.0.~o,~-,, Check One Probe(s) Depth(R) Date Time RemaH~ Remarks Co Relinquished By:. (Signature/Date) Lab Relinquished By: (Signature/Date) Ished By:. (Sl~ature/Date) Lab Relinquished By: (Signature/Date) Remarks: [] Two Data 8heats (one with TVHC & one without) PART #SF01 Rev. O~ ~003 WHITE - Return ~qth samples to I~h PINK - Fill Out Fo~ Completely !! Please Print Clearly !! [ Map Check List ~ Tank Details Total ~ Tank Numbor Numar Of Tanks ~ Tank OutCries ~ea~by Bu~din~s ~ ~umBorod P~oBo Locations ~ Tank 8izo On ~ Pipin~ Locations ~ Ground Go~o~n~s ~ Probo Lon~hs ' Total ~ Tank Product ~ ProBes[ ; ~ Numbor ~ T~aco~ in Tank .Tota1 ~ Dispensers Idonfifiod ~ Blank Location Lon~h } 1.S' ~,t I~' I ~* Of Probes ~ Fm Pipo 0 ~ Von~ Pipes ~o~h Diro~ion ~ Numbor ~umbo~ Of ' Of ~ Ma~olds Tested ~ Fill Locations ~onitoring Wells t ~ g I ~ Sump Pump Tanks 1 inch = ~ft. Tracer Research Job No. 860289 Page 3 of 7 Sample Date: 10/09/03 CONDENSED DATA Location Compound Concentration 001 A 0.00024 001 R 0.0003 001 W 0.00000 001 TVHC 0.02500 002 A 0.00002 002 R 0.0000 002 W 0.00000 002 TVHC 0.00600 003 A 0.00001 003 R 0.0000 003 W 0.00000 003 TVHC 0.02100 004 A 0.00059 004 R 0.0000 004 W 0.00030 004 TVHC 6.87900 005 A 0.00034 005 R 0.0010 005 W 0.00006 005 TVHC 17.38800 006 A 0.00004 006 R 0.0000 006 W 0.00016 006 TVHC 8.49700 007 A 0.00000 007 R 0.0000 007 W 0.00000 007 TVHC 3.69000 008 A 0.00000 008 R 0.0000 008 W 0.00000 008 TVHC 34.54900 009 A 0.00041 TVHC (Total Volatile Hydrocarbons) values reported in milligrams/liter (mg/L). Tracer A, and W values reported in milligrams/liter (mg/L). Tracer E, G, H, R, and I values reported in micrograms/liter (p.g/L). 0.00000 = Not Detected -999999.99999 = No sample Tracer Research Job No. 860289 Page 4 of 7 Sample Date: 10/09/03 CONDENSED DATA Location Compound Concentration 009 R 0.0000 009 W 0.00000 009 TVHC 26.22700 010 A 0.00316 010 R 0.0016 010 W 0.00004 010 TVHC 43.69800 011 A 0.00288 011 R 0.0007 011 W 0.00006 011 TVHC 48.45400 012 A 0.00016 012 R 0.0001 012 W 0.00000 012 TVHC 42.01400 013 A 0.00019 013 R 0.0001 013 W 0.00002 013 TVHC 81.70300 014 A 0.00000 014 R 0.0001 014 W 0.00000 014 TVHC 11.26800 015 A 0.00000 015 R 0.0003 015 W 0.00000 015 TVHC 13.32900 016 A 0.00014 016 R 0.0006 016 W 0.00005 016 TVHC 17.50200 017 A 0.00000 017 R 0.0002 TVHC (Total Volatile Hydrocarbons) values reported in milligrams/liter (mg/L). Tracer A, and W values reported in milligrams/liter (rog/L). Tracer E, G, H, R, and 1 values reported in micrograms/liter ([tg/L). 0.00000 = Not Detected -999999.99999 = No sample Tracer Research Job No. 860289 Page 5 of 7 Sample Date: 10/09/03 CONDENSED DATA Location Compound Concentration 017 W 0.00000 017 TVHC 0.57200 018 A 0.00000 018 R 0.0000 018 W 0.00000 018 TVHC 0.27200 019 A 0.00000 019 R 0.0000 019 W 0.00000 019 TVHC 0.27500 020 A 0.00000 020 R 0.0000 020 W 0.00000 020 TVHC 0.00200 021 A 0.00000 021 R 0.0041 021 W 0.00002 021 TVHC 1.18700 022 A 0.00076 022 R 0.0025 022 W 0.00211 022 TVHC 11.81400 023 A 0.00000 023 R 0.0000 023 W 0.00000 023 TVHC 4.37800 024 A 0.00001 024 R 0.0000 024 W 0.00000 024 TVHC 3.18100 025 A 0.00454 025 R 0.0043 025 W 0.00084 TVHC (Total Volatile Hydrocarbons) values reported in milligrams/liter (mg/L). Tracer A, and W values reported in milligrams/liter (mg/L). Tracer E, G, H, R, and I values reported in micrograms/liter (gg/L). 0.00000 = Not Detected -999999.99999 = No sample Tracer Research Job No. 860289 Page 6 of 7 Sample Date: 10/09/03 CONDENSED DATA Location Compound Concentration 025 TVHC 61.27100 026 A 0.00346 026 R 0.0013 026 W 0.00072 026 TVHC 16.31400 027 A 0.00003 027 R 0.0000 027 W 0.00000 027 TVHC 1.50100 028 . A 0.00001 028 R 0.0000 028 W 0.00001 028 TVHC 0.28200 029 A 0.00016 029 R 0.0000 029 W 0.00014 029 TVHC 2.44200 030 A 0.00006 030 R 0.0000 030 W 0.00000 030 TVHC 0.12500 031 A 0.00000 031 R 0.0000 031 W 0.00000 031 TVHC 0.06100 Clear DSL T-3 A 0.00111 Clear DSL T-3 R 0.0184 Clear DSL T-3 W 0.00001 Clear DSL T-3 TVHC 3.42400 LS-DSL T- 1 A 0.00006 LS-DSL T- 1 R 0.0000 LS-DSL T- 1 W 0.00001 TVHC (Total Volatile Hydrocarbons) values reported in milligrams/liter (mg/L). Tracer A, and W values reported in milligrams/liter (mg/L). Tracer E, G, H, R, and I values reported in micrograms/liter (gg/L). 0.00000 = Not Detected -999999.99999 = No sample Tracer Research Job No. 860289 Page 7 of 7 Sample Date: 10/09/03 CONDENSED DATA Location Compound Concentration LS-DSL T- 1 TVHC 0.48900 Prem T-2 A 0.00017 Prem T-2 R 0.0000 Prem T-2 W 0.00037 Prem T-2 TVHC 4.89100 T- 5 A 0.00100 T-5 R 0.0000 T-5 W 0.00134 T-5 TVHC 2.79100 T-6 A 0.00000 T-6 R 0.0060 T-6 W 0.00002 T-6 TVHC 0.04700 Unl T-4 A 0.00298 Unl T-4 R 0.0000 Unl T-4 W 0.00297 Unl T-4 TVHC 118.82600 TVHC (Total Volatile Hydrocarbons) values reported in milligrams/liter (mg/L). Tracer A, and W values reported in milligrams/liter (mg/L). Tracer E, G, H, R, and I values reported in micrograms/liter (gg/L). 0.00000 = Not Detected -999999.99999 = No sample Praxair Services, Inc. Tank 2 Tank 4 Tank 6 10,000 gal 20,000 gal 20,000 gal B u i 1 d i n g Premium 87 Unleaded EPA Diesel Tracer [W] Tracer [A] Tracer IR] Tank 1 Tank 3 Tank 5~ Entrance D i r t 10,000 gal 20,000 gal 20,000 gal L-S Diesel Clear Diesel Dyed Diesel Tracer [A] Tracer IR] Tracer [W] 17 4 Building 19 F e n c e 860289  S H I R L E Y E N V I RO N M E N T A L Wholesale Fuels EXPLANATION 2200 E. BRUNDAGE LANE '1 Sampling Probe Location BAKERSFIELD, CALIFORNIA ....... Approximate Pipeline Location 0 10 20 / S A M P L I N G L 0 C A T I 0 N S / f e e t Arc:860289-5 Date:10 22-03 F i g U r e 1 Prax&ir Services, Inc. Tank 2 Tank 4 Tank 6 10,000 gal 20,000 gal 20,000 gal B u i 1 d i n g premium 87 Unleaded EPA Diesel Tracer [WI Tracer [A] Tracer IR] Tank 1 Tank 3 Tank 5 Entrance D i r t 10,000 gal 20,000 gal 20,000 gal L-S Diesel Clear Diesel Dyed Diesel Tracer [A] Tracer [R] Tracer [WI 17 4 (0.00024) ] 18 (ND) Building 19 (ND) (0.00002) 2 } } (0.00001) 3 (0.00001) F e n c e 860289 S H I R L E Y E NV I R O NM E N T A L EXPLANATION Wholesale Fuels · 1 Sampling Probe Location N 2200 E. BRUNDAGE LANE ....... Approximate Pipeline Location BAKERSFIELD, CALIFORNIk 0 10 20 Tracer IAI Distribution (0.0002) Soil Gas S~ple Value (mg/L) { I. f e e t File:860289-2 Size:A Arc:860289-5 Date:10-22-03 F i g U r e 2 Praxair Services, Inc. Tank 2 Tank 4 Tank 6 10,000 gal 20,000 gal 20,000 gal B U i 1 d i n g Premium 87 Unleaded EPA Diesel Tracer [W] Tracer [Al Tracer [R] Tank 1 Tank 3 Tank 5 D i r t Entrance 10,000 gal 20,000 gal 20,000 gal L-S Diesel Clear Diesel Dyed Diesel Tracer IA] Tracer [RI Tracer [W]  17 (0.0002) (~)4 (0.0003) 1 18 Building 19 (~) 3 F e n c e 860289 S H I R L E Y E N V I R O NM E N T A L EXPLANATION Wholesale Fuels · l Sampling Probe Location N 2200 E. BRUNDAGE LANE ....... Approximate Pipeline Location B A K E R S F I E L D , C A L I F 0 R N I A 0 10 20 { Tracer [RI Distribution / ~0.0002) Soil Gas Sample Value (Dg/L) - f e e t File:860289-3 Size:A F i g U r e 3 Arc:860289-5 Date:10-22-03 Praxair Services, Inc. Tank 2 Tank 4 Tank 6 10,000 gal 20,000 gal 20,000 gal B u i 1 d i n g Premium 87 Unleaded EPA Diesel Tracer [WI Tracer IA] Tracer IR] Tank 1 Tank 3 Tank 5 D i r t Entrance 10,000 gal 20,000 gal 20,000 gal L-S Diesel Clear Diesel Dyed Diesel Tracer [Al Tracer IR] Tracer [W] 17 (~) 4 (ND) 1 18 (ND) Building 19 (ND) (ND) 3 (0.00001) F e n c e 860289 S H I R L E Y E N V I R O NM E N T A L EXPLANATION Wholesale Fuels · 1 Sampling Probe Location N 2200 E. BRUNDAGE LANE ....... ApDr'oximate Pipeline Location B A K E R S F I E L D , C A L I F O R N I A 0 10 20 'Tracer[W]Distribution{ (0.0002) Soil Gas Sample Value (mg/L) % { { f e e t File:860289'4 size:A ARC:860289-5 Date:10-22-03 F i g U r e 4 Praxair Services, Inc. Tank 2 Tank 4 Tank 6 10,000 gal 20,000 gal 20,000 gal B u i 1 d i n g Premium 87 Unleaded EPA Diesel Tracer [W] Tracer [A] Tracer [R] Tank 1 Tank 3 Tank 5 Entrance D i r t 10,000 gal 20,000 gal 20,000 gal L-S Diesel Clear Diesel Dyed Diesel Tracer [A] Tracer IR] Tracer [W]  17 (0.57200) (6.87900) 4 (0.02500) 1 18 (0.27200} Building (0.06100) 19 (0.27600) (0.00600) 2 { (0.02100) 3 (3.69000) (0.28200) F e n c e 860289  S H I R L E Y E N V I R O N M E N T A L EXPLANATION Wholesale Fuels · 1 Sampling Probe Location N 2200 E. BRUNDAGE LANE ....... Approximate Pipeline Location BAKERSFIELD, CALIFORNIA 0 10 20 { T V H C D i S t r i b u t i o n ~ (0.0002) Soil Gas S~ple Value (mg/L) f e e t File:860289-5 Size:A Arc:860289-5 Date:10-22 03 F i g U r e 5 APPLICATION TO PERFORM A TANK !i ~ ~nvironment~l Services TIGHTNESS TEST i5~ 1715 Chester Ave i,i~ Bakersfield, CA 93301 FACILITY :: ,,, O~T~S ~ O~ER~ ~E~ '.' NUMBER OF T~KS TO - .; 5 , ~; BE ...... ~S~ ~ I 18 ~NG ~ING TO BE TES~ ~ 0 NO '4 ~? ~.o. C~.T~ V~U'M~ ..... MAIUNG ~DRESS ~E & PHONE NUMBER ~ C~TACT TEST ME~ ~E OF TES~R ~ & TiME ~T IS TO BE ~NDUC~ rd208' ' T 2 :PREM ~INLEADED T 5 :DYED D I ESEL " . :-- PRODUCT CODE : '2 PRODUCT CODE 5 THE,RI'`IAL COEFF :. 000750 THERMAL COEFF .000450 TANK- DIAMETER : ,9-5.00 ' TANK DIAMETER 120.00 : TANK PROFILE : 1 PT TAN],: PROFILE : 1 PT SYSTEM SETUP ,- FULL VOL : 10000 FULL VOL : ,-'05b. OCT 8. 2003 9:lb AM HIGH L,,ATER LIMI;T: 4.0 HIGH bJATER LIMIT 4.0 OVERFILL LIMIT : 95~: OVERFILL LIMIT 95% : 9500 19o..535 ENGLISH HIGH LEVEL LIMIT: 95% HIGH LEVEL LIMI'T: 95% U.S. : 9500 : 19535 b,.IHOLESALE FUEL LOI,,,I LEVEL LIMIT 500 LObJ LEVEL LIMIT : 500 2.c..Ot E BRUNDAGE LN LEAK ALARM LIMIT 75 LEAK ALARM LIMI'F: 75 BAKERSFIELD CA THEFT LIMIT 100 THEFT LIMIT : 100 9{3304 TANK TILT '-' 95 TANK TILT .~ : 0.00 SHIFT TIME 1 2:00 AM MANIFOLDED TANKS MANIFOLDED TANKS SHIFT TIME '2 4:00 APl TANK~: NONE TANK~: NONE SHIFT TIME ~ 7:00 PM DEL I VERY DELAY : 1 M I N DEL IVERb." DELAY : 1 M I N SYSTEM SEf::l_Ik '/ CODE : 000000 T 3:C:LEAR DIE~EL T S:EPA DIESEL PRODUCT CODE : 3- PRODUCT t..OlE : 6 THERMAL COEFF :. 000450 THERMAL C'OEFF :. 000450 TANK DIAb`lETER : 120.00 TANK DIAMETER : 1ZO. O0 TANK PROFILE : 1 PT TANK PROFILE : 1 PT FULL VOL : 20563 FULL VOL : 20563 HIGH I,,IATER LIMIT 4.0 HIGH b. IATER LIMIT 4.0 OVERFILL LIMIT 9._,..,, OVERFJLL LIMIT 95?4 C::OMMUN I CAT I <TUP 195:35 19585 NONE FOUND HIGH LEVEL LIMIT: 95% HIGH LEVEL Lit'liT: 95.% : 19535 : 195:35 CODE : 00[ LOk,.I LEVEL, LlPlIT : 500 / LOkJ LEVEL LIMIT : 500 LEAl( ALARM LIMIT: 75 LEAK ALARM LIMIT: 75 -- THEFT LIMIT : 100 THEFT LIMIT : 100 '< TANK TILT : 0.50 TANK TILT : 2.00 b`lgN I FOLDED T::.hHK',.z:: MAN I FOLDED TANKS TANK~: NONt TANKI:t: NONE DEL IVERY DEbqY : 1 PlI N I'~EL I VERY DELAY : 1 M I N T 4:UNLEADED T 7:EPA '2 I N-TANK SETUP ~ PRODUCT CODE : 4 PRODUCT CODE : 7 ......... THERMAL COEFF :. 000700 THERMAL COEFF :. 000450 TANK DIAPlETER : 120.00 TANK DIAMETER : 120.00 T I:L-.c-', DIESEL TANK PROFILE : 1 PT TANK PROFILE : 1 PT FULL VOL : 205b. FULL VOL : 20568 PF.'ODUC'F C.' ?,DE : 1 THEFfbPlgI_. OOEFF :.000450 HIGH I,,IATER LIMIT: 4.0 HIGH t,,,IATER LIMIT 4.0 : 195:35 19946 F:Ii.L '../01. : 10000 HIGH LEVEL LIMIT: 95% HIGH LEVEL LIMIT: : 195~5 : 20857 HIGH i.,JATER LIMIT 4.0 OVERFILl. LIMIT 95% LOI.~t LEVEL LIMIT : 51710 LOL4 LEVEL LIMIT : 500 9500 LEAK ALARM LIMIT: 75 LEAK ALARM LIMIT: 75 THEFT LIMIT : 100 THEFT LIMIT : 100 HIC;H LEN,,'~: ...:,lIT: '_a. 5;~ TANK TILT : 0.00 TANK TILT :- 2 00 : 9500 ' MAN I FOLDED TF~NKS MAN IFOLDED TANKS LOkl LEVEL LIMIT 500 TANK$I: NONE TANKer: NONE LEAK ALARM LIPIIT 75 THEFT LIMIT 100 DELIVERY DELAY : 1 MIN -" !VERY DELAY : 1 MIN TANK TILT 2.40 MANIFOLDED TANKS TANKII: NONE DELIVERY DELAY : 1 MIN T 8:U.L.S.C DIESEL PRODUCT CODE 8 THERMAL COEFF .000450 TANK DIAMETER 96.00 GROUNDWATER SETUP TANK PROFILE : 1 PT FULL \/GL : 12000 NONE HIGH I~ATER LIMIT: 2.0 LEaK TEST REPORT OVERFILL LIMIT : 95% T 2:P~EM UNLEADED : 11400 TEST ~T~RTI NG TIME HIGH LEVEL LI~IT: 95% ; I1400 OCT 5, 2003 2:00 LOt4 LEVEL LIMIT : 100 TEST LENGTH 2 HOURS LE~K ~L~gM LIMIT; 99 STARTING TEP1P = 89 THEFT LIMIT : 99 ENDING TEMP = 89 2 TAME TILT : 5.00 EXTErNaL INPUT SETUP ' ...... LE~ TEST ~ESULTS M~NIFOLDED TANKS NONE STARTING VOLUME= 3649 TANK~: NONE DELIVERY ~ELAY ' : 15 MIX TEST HOURS 1-1 0.00 -0.01 0.00 0.20~L,/HR TEST OLITPUT RELAY SETUP R 1 :PO8 EP~ LE~K TEST METHOD IN-T~NK ~L~'IS ~ ............. T 7 :OVE~ILL aLaRM T 7:HIGH LIPIIT ~L~RM TE~T MONTHLY : aLL TaNK WEEK 1 SUN R 2: START TIME : 2:00 AM - NO ALARM ASSIGNMENTS - REPORT ~AI'E: ~.'2 GAL/HR DURATION : 2 HOURS R 3: - NO ALARM ASSIGNMENTS - LEAK TE~T REPORT x R 4: T 3:CLEAR DIESEL - NO ALARM ABSIGNMENTS - TEST ~TARTIN~ TIME: OCT 5 2003 2: O0 AM TEST LEIqGTH '2 HOURS STARTING TEMP = 89.3 F ENDING TEMP = 89.3 F I. IL~UI[:, SENSOR SETUP LEAK TEST RESULTS STARTING VOLUME= 7502 TEST HOURS 1-1 LEaK TEST REPORT NONE .................... T I:L-S DIESEL 0.03 0.09 0,11 TEST c, laRTIN~ TIME: LEaK RaTE 0,07 LqgL. HR OCT 5., 2003 2:00 aM 0,2 GRL~.-"H~ TEST PaSS TEST LENGTH 2 HOURS STARTING TEMP = 88,9 F ENDING TEMP = 88,9 F LEaK TEST RESULTS VAPOR SENSOR SETLIP } STARTING VOLUME= 6379 TE~T HOURS 1-1 NONE .................... -0,00 O.OO -0.00 LEAK RATE = -0.00 GAL/HR TE,..,T PASS O. 2 GAL/HR ~ / "~-,, LEAK TEST REPORT LEAF TEST REPORT T///4: "~-- T 8:U.L.S.¢ DIESEL . UNLEADED LEAK TEST REPORT TEST STARTING TIME: TEST STAR'rING TIME: OCT 5, 2003 2:00 AM OCT 5.. 2003 2:00 AM T 6:EPA DIESEL TEST STARTING TIME: TEST LENGTH 2 HOURS TEST LENGTH 2 HOURS OC, T 5.. 2003 2:00 Aid STARTING TEMP = 75.4 F STARTING TEMP = 89.7 F ENDING TEMP = 74.3 F ENDING TEMP' = 89.7 F TEST LENGTH 2 HOURS LEAK TEST RESULTS LEAK TEST RESULTS STARTING TEMP = 85.8 F STARTING VOLLIME= 2604 STARTING VOLUME= 12829 ENDING TEMP = 85.8 F TEST HOURS 1-1 TEST HOURS 1-1 LEAK TEST RESULTS .................... .................... START I NO VOLUP1E= 151420 O. 22 O. 39 O. 58 0.05 -0.13 -0.07 TEST HOURS 1-1 LEAK RATE = 0.39 GAL/HR LEAK RATE = -0.05 GAL/HR 0.00 0.04 0.04 0.2 GAL/HR 'rEST INVALID 0.2 GAL/HR TEST PASS LEAK RATE= O. 03 GAL./HR 0"-)~- GAL/HR FLAGS: LOW LEVEL TEST ERROR CHANGE IN TANK TEMP ZONE 0.2 GAL/HR TEST PASS TEMP CHANGE TOO LARGE LEAK TEST REPORT T 5 :DYED D I ESEL ALARM H I STORY REPORT LEAK TEST REPORT TEST STARTING TIME: PAPER OUT OCT 3.. 2003 4:51 PM OCT 5, 2D03 2:00 AP1 T 7:EPA 2 PRINTER ERROR TEST STARTING TIME: OCT 3. 2003 4:51 PM TEST LENGTH 2 HOURS OCT 5, 2003 2:00 AM BATTERY IS OFF STARTING TEMP = 91.4 F JAN 1.. 1991 S:O0 RM ENDING TEMP = 91.4 F TEST LENGTH= o HOURS L, ERK TES? RESLI%M STRRTING TEMP 79 6 F STARTING VOLUME= 8598 ENDING TEMP = 78,3 F TEST HOURS t-1 LEaK TEST RESLL%_, .................... STaRTING VOLUME= 1 ?06 0.05 0.13 O,t3 TEST HOURS 1-1 LEAK RaTE = 0.09 GaL/HR .................... ALARM HISTORY REPORT -0,04 -0.07 -0.16 TRNK NUMBER 1 0.2 GaL/HR TEST PaSS LEaK RATE = --0.10 GaL/HR L-S DIESEL . HIGH klATER ALARM 0.2 GAL/HR TEST PASS PI~V 26, 2002 6:49 ~M JUL 1, 2000 9:~1 PM -¢ OVERF ILL ~LRRM JU~ 10.. 2003 10 08 PM FEB 16, 2003 1 04 PM ~. ~ DEC 'VD. o '~ HIGH LIMIT ~L~RM " . 5UN 10, 2003 10:08 PM ...... FEB 16, 2003 1:04 P~ " DEC 29, 2002 5:39 PM JAN 16 2~0~- 31 PM PROBE OUT DEC 12, ~02 e:O8 AM DEC 12. 2002 5:41 ~ld DEC 12.. 2002 5:34 ~M ALARM HISTORY REPORT -- TANK NUMBER 3 ALARM HISTORY REPORT CLEAR DIESEL TANK NUMBER 5 ALARM HISTORY REPORT HIGH WATER ALARM DYED DIESEL MAY 21, 2003 3:44 PM TANK NUMBER 2 MAY 14, 2003 8:13 PM LEAK ALARM PREM UNLEADED MAY_5,_.2003__8:42 PM .... JUL 11, 2003 1:17 PM HIGH WATER ALARM OVERFILL ALARM JUL 6, 2003 4:00 AM FEB 11, 2002 11:08 AM AUG 7. 2003 5:43 AM HIGH WATER ALARM SEP 23. 2000 5:08 PM AUG 5, 2003 ~:24 PM AUG 19, 2003 10:32 PM AUG 5, 2003 9:30 AM JUL 21. 2003 1:43 APl OVERFILL ALARM JUL 17, 2003 8:41 AM AUG 22, 2000 7:30 PM HIGH LIMIT ALARM JUL 1, 2000 1:15 PM AUG 7, 2003 5 43 AM OVERFILL ALARM DEC 16. 1999 2:34 PM AUG 5, 2003 4 25 PM SEP 17, 2009 7:00 PM AUG 5, 2003 9 30 AM SEP 3. 2003 1:57 PM HIGH LIMIT ALARM SEP 3, 2003 1:22 AM AUG 22, 2000 9:30 PM INVALID FUEL LEVEL JUL 1, 2000 1;15 PM JUL 19.. 2003 10:O0 AM LOW LIMIT ALARM DEC 16, 1999 2:35 PM MAY 7, 2003 10:02 PM JUL ?, 2000 2;01 PM MAY 7, 2003 12:33 AM INVALID FUEL LEVEL THEFT ALARM BEP 9, 2003 11:54 AM PROBE OUT JUL 11, 2003 12:51 PM APR 6.. 2003 6:19 APl SEP 16.. 2009 4:33 PM JUL 6, 2003 3:47 AM MAR 14, 2003 5:13 PM MAY 14, 2003 8:13 PM MAY 8, 2003 11:40 PM HIGH LIMIT ALARM SEP 17, 2003 7;00 PM SEP 3, 2~003 1°:57 PM SEP 3, 2003 1:23 AM INVAL~-?~EL--kEVE-L- - JUL 19, 2003 2:51 PM JUN 1~, 2003 2:19 AM MAY 12, ?~]03 1~:50 PM ALARM HISTORY REPORT PROBE OUT ALARM HISTORY REPORT JUL 25. 2003 5:58 PM TANK NUMBER 2 JUN 29, 2003 9:04 PM PREM UNLEADED TANK NUMBER 4 MAY 14, 2009 12:01 AM UNLEADED HIGH WATER ALARM FEB 11, 2002 ll:OB AM OVERFILL ALARM SEP 23, 2000 5:08 PM SEP 30, 2003 6:18 PM ~EP 80, 2003 4:34 PM OVERFILL ALARM SEP 27, 2003 5:09 PM .- ~.. ·" ' AUG 22, 2000 7:30 PM '~ ~"" JUL 1.. 2000 1;15 PM HIGH LIMIT ALARM DEC 16, 1999 2;34 PM SEP 30, 2003 4:94 PM SEP 27, 2003 5:09 PM HIGH LIMIT ALARM 8EP 25, 2003 6:45 PM AUG 22, 2000 9:30 PM JUL 1, 2000 1:15 PM i- INVAL-I-D--FOEE-I]EVEL - DEC 16, 1999 2:95 PM ~ JUL 9, 2003 8:15 AM JUN 17, 2003 10:56 PM INVALID FUEL LEVEL MAY 9, 2003 I1:44 AM SEP 3. 2003 11:54 AM APR 6, 2003 6:19 AM MAR 14, 2003 5:19 PM - 3' ALARIq HISTORY REPORT ~LARM H I STORY REPC RT ~L~RM HISTORY REPORT T~NK I~UMBE~ TANK NUMBER 7 ,~ iES~ U.L.S.L' D TANK NUMBER 6 EPA ~ EPA DIEBEL LEAK ALARM LEAK ~LA~lq LEAK ALARM APR 1, 2001 3:30 AM ~UN ~. ~000 4:00 JUN 3, 2001 4:00 AM FEB 4, 2001 ~:00 AM NOV ' - NOV 5.. 2000 3:80 AM OCT 1 2000 3:30 AP1 /~ATER ~LARIq BEP 24, 2008 5:29 PM AUG 29, aO0 6:13 AM JUL t8, zOc~ ' JLIL 11, 2003 2:09 P'M JUN 10, 2001 9:43 PH JON 7, 2003 5:37 AH FEB 14, 9001 4:42 PR OVERFILL ALARM OVERFILL A~RM~...,0 PPl ;' ~B lO.. ~,~, 8:08 ~'''' MAR 14.. 2003 3 04 AM AUG 18.. 20U3 ~'~ ~B 6, DEC 24.. 2002 12 41 PM AUG 17, 2003 4:3~ PM DEC 22, 2002 7 13 ~'1 AUG 11, 2003 6:45 AN THEFT RL~RP1 THEFT ~LARM LOW LIMIT ALARM JUN ~ ~000 3:54 AM JUN 3, 2001 3:31 AH SEP 5, ~03 ~:51 6M NO~ NOV 5.. 2000 9:59 AM AUG 14, 2003 5:~ AM pitt ALARP1 '- IGH LI o 3:44 ~M HIGH LIMIT ~L~RM JUL 2~, 2003 3: ~Pl H ~3 MAR 14, 2003 3:04 AM THEFT ALARM ~- -~' DEC 22, 2002 7;13 AM SEP 2.. 2001 3:59 AI'~ FEB 6, - SEP d-O,. 28~2-~1q-5~-- APR ~ ~01 ~:20 A~ I LEVEL -- .. 2:07 PM INVALID FUEL LEVEL FEB 4, 2001 3:36 AM iNVALID FUEL J~N 3, 0002 SEP 12, 2001 5:29 PM HIGH LIMIT ALARH~ NO~ 21, ~002 4:36 PM AUG 31, 2001 3:23 ~M NOV 1.. 2002 6:B3 PM NOV 20, JUL 11, 2001 8:26 PM oCT 20, 2000 5:3~ AM pROBE OUT PROBE OUT OCT 19, 2000 4:53 AM 1, oOOt A~ ~ ~qq9to:tO aM DEC SEP 24, 2003 5:29 PM INVALID FUEL LEVEL NOV 11, 2001 10:28 ~M JUL 2~, 2003 3:48 ~M Nov ~,. 2oo~ ~o:25 6M JUL 20, 200~ ~::~4 6M JUN 2?, 2003 21 PM pROBE OUT ~-- FEB 14, 2001 4:38 PM ..-.' -'~"" DEC 26, 2000 3:59 PM ' DEC 26, 2000 3:57 PM 3'28/01i 07:45 "~8§ 28 0578 BFD ~IAZ ,~IAT illI ' ~/OOZ MONITORING SYSTEM CERTIFICATION ' t:'or Use By All d, risdicnotts Witln'n th~' $tet(e of C~tlifornia Aathori(y Cited: Cht~pter 6. 7. Health and Safety Code: Chapter I~. Division 3. Title 23. C~tliJbrnitt Code ~ff Reg~datio~$ T t'orm must be used to document testln~ and so,icing of monitoring equipment. A seoarate certification or repo~ tS{ ' eac~gnitorin~ system centres ~a~ by the technician who peHorms the work. A copy of this t~rm must be pr.ovided to the tank s'. ;tern owner/opera~or. The owner/operator must submit a copy et' {hi~ tb~ ~o the local agency regulating UST systems within 30 d: ~s of test date. ~ General Information ~J Inventory of Equipment 'l este~Cert~ed . }ck ta~ ~pproprl~t,. poxes to Indicate ~lnc, 5mpm~nt Model: O Annul~ Spac* or Vault S~nSot. Mod~l: : Sump / Trench Sgnsoffs). Mod~l: ~ Piping Sump/Trench S~nsogg. Model: ~ S~n~or(s). M~h g Fill Sump g~nsor(s). Model: Line Lc~ De(octet. Model: ~ M~h~ical Line Leak Dc[octet. Model:' lec~onic Linc Leak Detector. Model: ~m~ ~,~C~ ~ EIcc~onic Line ~ Detector. Model: Overfill / High-Levdl SenSor. Model: · ~ T~k Oveclll / High-Level Sensor. Mqdel: ~d model in Section E on model in Section E on n-Tank Gauging Probe· Model: ~ ~ In-T~k Gaugihg ~obe. Model: Sffnsor. Model: O Annul~ Space or Vault S~n;or. Model: '/ping Sump / Trench Sensogs). .Model: O PipingSump / Trench Sensor(s)· Model: qll Sump Sensor(s). M~cl': ~ ~ Fill Sump Sensor(s). Model: : Line Le~ Detector. Model: ~ Mechanical Line Le~ ~tector. M~el: ;lec~onic Line Le~ Detector. Model: ~m~ ~t~ ~ Elee~onie Lin~ &~ Detector. Model: k Ove~ll / Hi, h-Level Sensor. 'Model: ~ Tank Oveffill/ High.Level Sensor. Model: ~e and model i~ Section B ~e and model in SectiOn E on )i~penserCont~nment Sensor(s). Model: ~ Dispenser Containment Sensor(s). Model:. he~ Vflve(~). ~ Shear V~ve(,). Containment Heat(s) and Chain(~). 'lost(s) ~d Chain(~. ~' ~ ' ~ Dispenser Containment Sensor(s). Model: ~spen~ercontammen~ Sensor(s). Mod,h  JVear Val,'e~s). ~ Shear Valve(s). ~.~ispcnser Cent,inmont ~oat(s) ~nd Chain(s). ~ Dispenser Con~ainmem Float(s) ~nd Chain(s). ~ g j~ispenser Containment S,nsor{s). Model:. a Dispen,er Cont~nment Sensor(s). Model: J ~'~hear Valve(s). ~ Shear Valve(s). ~ '~Jspenser Coatainmen; Float(s) and Cllain(s). ~ Dis~set Cont~nment F~oat,(s~ and Chain(~), .'If ~e facili~ contains more tanks or dispensers, copy this ~o~. Include infom~ation for every t~k and dispenser at the facility. ~. Coati,cation · I ce~ that, the ~pipment lden~ in t~s document w~ lmpeet~e~leed In accordance with the m~ufac~e~' g~delln~. Attached to this Ce~flcation Is I~o~on (e.g: ~nufac~re~' chec~ls~) neee~sa~ to ve~ that correct and a Plot Plan Showing the layout of mo~to~ng ~ent. For any ~q~p~ent ~pable of generating such report. I have also attached a copy or the rep9~; (check ~1 that apply): ~ystem set.up ~Marm history report Te nician N~e (pdnt): ~q~ ~~~ : ,.. Signature: Te ngCompany Name: ~O~t~ ~m~ · Phone No.:(~_) Sit~ hddres;:. ,~ ~ ~~~ OL 'Date of Testing/Servicing: Page I of 3 03101 itoring System certilScation 0 )28/01~ 07:45 ~66 26 0578 BFD HAZ )IAT ' ~o02 MONITORING SYSTEM CERTIFICATION For Ose Bv All Jurisdicnons Within thc Sta~e ¢,f California Attthori(y Cited: Chapter 6. 7, Health w!d Safety Code: Clmpter 16. Division 3. Title 23. Cul~bmia Code of Regtdations i~ tbrm must be used to document t~stlng cna s~icing of monitoring equipment. ~ Scoarat~ certj)icadon or rcpo~ must b~ ofepar~d ~ac~gnitoring System c0n~rgl ~l~ by the technician who performs thc work. A copy of this t~rm must be p~ovided to thc tank cern owner/operator. Thc owner/operator must submi~ a copy or' this tb~ to the local agency regulating UST systems witMn 30 d ; o1' test date. ~ General Information F ~lity Name: t. ~~~ ~~~ Bldg. No.:... S~F Address: ~0_~'~~~ ~ City: ~~. Zip: ~k~°dell,. of Monitoring System: ~~ o[ Testing/Scatting:' ' ' ' ' ' / ~[ Inventory of Eqmpment I este~Cerufied C~"' k the appropriate boxes to lfld}cate specific ~pn, ent ~nul~ 5p~ce or Vault Sensor. Model:' ~ Annul~ Space or Vault Sensor. Model: ~i~ing Sump'/~rcnCh S~nso~), Mo~I: ~ ~ipifl~ Sump/Wrench S~nso~5). Mo~l: Sump Sensor(s). M~cI: ~ Fill Sump Sensor(s). Model: Lin, Le~ De~eetor. Model: ~ Moth,leal Line Le~k Detector. Model:' lec~onic Line Leak Detector. Modet:~ ~ Elee~onie Lin* ~ DetectOr. Mo~el: Overfill i High-Level SenSor. Modeb · ~ T~k Ove~]ll / 8igC-Level Sensor. Modeh ~d model in Section E on ~ Otker 0 in Section E on ~k ~: Ta~ ~: . n-Tank Gauging Probe. Model: ~ In-Tm~k Oauglhg ~obo. Model: Space or Vault Sinsor. Model: ~ Annul~ Spaeo or Vault S~nsor. Model: Sump / Trench Sen~o~s). . Model: ~ P~pingSump / Trench Sensor(~). Model: ~ , Sensor(s). M~el': ~ Fill Sump Sen,or(s). Model: Line Le~ Detector. Modeh ~ Mechanical Line Le~ ~teetor. M~eh colonic Line Le~ Detector. Model: ~ Elee~onie Lin, &~ Detector. Model: Ore,Il / High-Level Sensor. 'Mod~k ~ Tank Oveffill / ~igh-Leve! Sen~or. Mo~el; in $eedon E on Pa and model in SectiOn E on emer ID: Dis~nser ID: tispenserCon~hnment Sensor(s). Model: ~ Dispen,er Containment Son,ore). Model: ;he~ Vflve(s). ~ Shear Vflve(s). ~,er Containment ~oat(s) and Chain(s). Float(s) ~d Chain(s). Dhpenser ID: fispenserContainmem Sen,or(~). Mod~l: ~ Dispenser Containmenl Sensor(s). Model:  hear vah'er~. ~ Shear ValveO). ~. dspenser Containment ~oat(s) and Chain(s). ~ DiSpenser Containment ~l. pat(s~ ~nd Chain(s). ~[ Di~ onset ID: Dispenser ID: ' ~ Q~ ,ispenser Containment Sensor(s). Model'._,D.. hear Va ye(s) ~Q Dispenser Cont~nmem Sensor(s,. Model:shear Valve(s). ~: spenser ConmJnmem Float(s) and Clmin(s). Q..gisp~ser Cem~nmem Float(s2 and Chain(~).. .-Ifil[e facili~ contains more tanks or dispensers, copy this fo~. Include infom~ation for every t~k and dispenser at the t%cility. C.i~ certification · t come that the ~uipment lden~ in t~s document w~ lmpeet~se~leed In accordance with the m~u~ac~em' ~ ~Hde/In~. At~ched to thl~ Ce~flcntlon is I~o~Oon (e.g. ~nufac~re~' chec~ls~) necessa~ to ve~ that t~s f~ommtlon correct and a Plot Plan Showing the layout of mo~todng eq~ment. For any eq~pment ~pable of gene~ating such reporU, [ have also attached a copy of the repo~: (chec& d[I thai apply)~ ~System se/.up ' ~ Alarm history report To, ~ici~ ~e (print):~~[~W~_ ~ ~_ Signature: Xe~ ,~CompanyName:~~~ ~~amL VhoneNo.:(~/ _) Sit AOdress: ~~ o ~~ ~ Date ot'Testing/Servicing: ~/~/ Page I or3 M~ Rodng System Certiflcadon 0.9,'28/01 07:46 e~66. 26 0576 BFD HA2 blAT " /~003 D. Results of Testing/Servicing Software Version Insalled: ~ Com~dete ~he foilowin chec~is~: ~ Yes ~ No* {s the visual ala~ operational? .~ Yes O No* Wer~ all sensors visually inspected, f~nCti~n~lly tested]and c'onfi~ed operad~Ral] - · 2 Yes · No* Were ail sensors insalled at lowest point of secondly containm~n~ and positioned so that other equipmenz no~ interfere w[tl~ their p~er 0perafion'?. '~ Y~s ~ No'/ [f al~'"~e relayed to a remote monitoring station, is all com'municati'ons ~quipment (e.g. modem) ~ N/A ~ operadonai? ~ Yes' ~ No*~ For 'pressurized ~s~t~t~rbine automa~iCaliy 'shut dOWn ~f the piping seconda~ containment ~ N/A monitoring systzm detects a leak. fails ~o operate, or is electrically disconneczed? It"yes: which sensors iniziate positive shut-down? (Chec~ alt that appl? ~ Sump~r~nch Sensors: ~ Dispenser Containment Sensors. Did 7ou confi~ positive s~ut-down d.ue zo leaks ~ sensor failure/disconnection? ~Yes: ~ No., ~ ~es ~ No* ~ For tank systems that Utilize-the monitoring system as t~e pfim~ rank ove~ll w~ing d~ice (i.e. n° ~ N~A mechanical overfill prevention valve is insatled), is ~ ov~ll w~ing al~ visible ~d audible a~ ~he ~an~ fill point(s) a~ operating properly'? If so, a~ what ~rcent of tan~ capacity does the at~ ~i~$er? ~ ~ . % ~Ye~* ~ No Was any mo,itoring equipment r~pIaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manut~ccurer name and m~el for all replacemen~ p~s in Section E, below. ~ Yes* ~ No Was 'liquid"found inside any second~ cont~nment systems designed as d~ systems'? (~he'ck all ~hut apply] . . ~. Produc~ ~ Wa~r. [f 7es, describe ca~ses in. Section E,.b~low. . ~ Yes ~ No* Was monitoring systemsec-up reviewed ~o ensure proper settings? Attach set up reports, if a~plicab[e 9 Yes ~ No'~ ~ ~s ail monitori,ng ~uip~nt o~zratiogal p~r m~ufac~e~'s specifications? In Sec~on E below, desc~be how and when th~e deDclencies were or ~11 be corrected, Page 2 of 3 o'~/ot 09/28/01 07:47 "~'6( 26 0576 BFD HAZ NAT DI ~ ~004 F. · In-Tank Gauging / SIR Equipment: ~:) Check this box it' tank gauging is used only tbr inventory control. '@ Check this box ii: no tank gauging or SIR equipment is installed. ' This section must be completed if' in-tank gauging equipment is used to perform leak detection monitoring. Com,flete the..rollowin[~ checklist: ....................... all input wiring i tgl~ Yes Q No*'{ Has been inspec'ted lbr proper entry and termination, including testing for ground t'aults? ~ Yes ~l No*' Were all tank gauging probes visually inspecteci f'or dan~'~g~ and 'residue buildup? ~} Yes O No* Was accuracy of system product level read!ng~ tested'.) . .  Yes O No* Was ficcuraey oi' system ,,,tater level re~dings..tested'? Yes ~i No* Were all probes.reinstalled properly? ~Yes 0 No* Were ail items on the equipment manufacturer's maintenance checklist completed? · In the Section H, below,, describe how'and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): C3 Check this box it' LLDs are not installed. Corn ~lete the following checklist: ~1~ Yes ,"l No* For equipment start-up or annual equiPment certification, was a leak simulated to verify LLD performa-~¢e~ D N/A (Check all l&at apply) Slmulatedieakrate:~3g.p.h.: ~0.1g.p.h; /-10.2 g.p.h. . ~ Yes' ~ No* Were all LLDs confirmed operational and ac'e'~cate within r~gulatory require~nents? ~ Yes I~'No* Was the testing apparatus properly calibrated? '" ~ Yes ~/ No* For mechanical LLDs, does the LLD restrict product flow if it detects a Leak? ,'3 N/A ~ Yes ~] No* For electronic l£[~s, does the turbine automatically shut Off if the LLD detects a leak? ~ N/A ~ Yes ~ No* For electrofiic LLDs, does the 'iurbine'aut~matically shut off if any porti'~ of the monitoring System is disabled ~ N/A or discormected? ~10 Yes i~l N~*' For electronic LL[~iTdoes the turbine automatically shut off it' any portion of the monitoring system malfunctions ~D N/A or fails a test? T.~ Yes D No* For electronic LLDs, have all accessible wiring con~ections been Visually inspected? ~1 N/A ~ Yes '~ No* Were alt iter~s on t~e equil~'ment manut'acturer's'maintena~ce checklist completed? · · In the Section H, below, describe how and when these detlclencies were or will be corrected. Comments: Page 3 0/'3 03/0~ March 5, 2003 Wholesale Fuels P O Box 82277 Bakersfield CA 93380-2277 FIRE CHIEF RON FRAZE REMINDER NOTICE ADMINISTRATIVE SERVICES 2101 "H" Street Bakersfield, CA 93301 VOICE (661)326-3941 FAX (661) 395-1349 RE: Deadline for Dispenser Pan Requirements December 31, 2003 SUPPRESSION SERVICES 2101 "H' Street Dear Underground Storage Tank Owner: Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661)'395-1349 A Review of our files indicate that you have been receiving quarterly reminder notices since April of 2002. Effective January 2003, you can PREVENTION SERVICES ,~ES,~ms~cEs.E,~,o,~.,~,~s~m~c, expect them monthly. 1715 Chester Ave. Bakersfield. CA 93301 VOICE (661)326-3979 The purpose of this letter is to remind you of the necessary retrofit of FAX (661) 326-O576 your fueling system. Current code requires that you install dispenser PUBLIC EDUCATION pans prior to December 31, 2003. You will not be allowed to remain 1715 Chester Av~. ~kers.eU, c^ 93301 open after December 31, 2003 unless you have completed the upgrade VOICE (661)326-3696 requirement. Contractors are already scheduling work 6-8 weeks out. FAX (661) 326-O576 I urge you to start planning to retrofit your facility as soon as possible. FIRE INVESTIGATION 1715 Chester Ave. Sincerely, Bakersfield, CA 93301 FAX (661) 326-0576 TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 Steve Underwood FAX (661) 399-5763 Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/dc February 3, 2003 Wholesale Fuels P. O. Box 82277 ~Re c,,e~ Bakersfield CA 93380-2277 ADMINISTRATIVE SERVICES 2101 'H' Streel REMINDER NOTICE VOICE (661) 326-3041 FAX (661) 395-t 349 SUPPRESSION SERVICES RE: Deadline for Dispenser Pan Requirements December 31 2003 2101 'lq' Stree! 6akersfleM, CA 93301 VOICE (661) 326-3941 Dear Tank Owner: ~,~x (66~)396-~9 unuergrounu atorage PREVE,'nO, SE,VICES A Review of our files indicate that you have been receivin,_:/_o quarterly $,N= ET~ S~RVlCES · F../4~RO~34TAL SF..q~c:ES ms C~,est.rAve. reminder notices since April of 2002. Effective January '2003, you can Bakersfield, CA 93301 voice (661) 326-3~7, expect them monthly. ~Ax (661) 32~76 The purpose of this letter is to remind you of the necessary retrofit of Puauc toUcA'noN ms C,ester^"". your fueling system. Current code requires that you install dispenser ~akors,o~.C^ ~.~01 pans prior to December 31, 2003. You will not be allowed to remain VOICE (661) 326-3696 ~Ax (661) :~s76 open after December 31, 2003 unless you have completed the upgrade me ~.VES~C~O. requirement. Contractors are already scheduling work 6-8 weeks out. I ms c~,~,^,, urge you to start planning to retrofit your facility as soon as Possible. Bakersfield. CA 93301 VOICE (661) 326-3951 FAX (661) 326-0576 Sincerely, 5642 Vlctor Ave. . , Bakersfield, CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services S B U/dc D January 22,2003 Wholesale Fuels FIRE CHIEF ~o~ F~*ZE P.O. Box 82277 Bakersfield CA 93380-2277 ADMINISTRATIVE SERVICES 2101 'H' Street Bakersfield, CA 93301 RE: Upgrade Certificate & Fill Tags VOICE (661) 326-3941 FAX (661) 395-1349 Dear Owner/Operator: SUPPRESSION SERVICES 2101 "H' Street Bakersfiold, CA 93301 Effective January 1, 2003 Assembly Bill 2481 went into effect. This VOICE (661) 326-3941 FAX (661) 395-1349 Bill deletes the requirement for an upgrade certificate of compliance (the blue sticker in your window) and the blue fill tag on your fill. PREVENTION SERVICES FIRE SAFETY SERIllCES . ENYlI~N~I:NTAL SER91CE$ 1715 Chester Ave. You may, if you wish, have them posted or remove them. Fuel Bakersfield. CA 93301 VOICE (661)326-3979 vendors have been notified of this change and will not deny fuel FAX (C~1) 326-0576 i delivery for missing tags or certificates. PUBLIC EDUCATION 1715 ChesterAv& ;. Should you have any questions, please feel free to call me at 661- Bakersfield, CA 93301 ' 326-3190. VOICE (661) 326-3696 FAX (661) 326-0576 FlEE INVESTIGATION olly°-*nccre'-,~. ' 1715 Chester Ave. VOICE (661) 326-3951 / / FAX (661) 326-0576 TRAINING DIVISION St 5642 Victor Ave. Bakersfield, CA 90308 Fire Inspector/Environmental Code Enforcement Officer VOICE (661) 399-4697 FAX (661) 399-5763 Office of Environmental Services SBU/dc Wholesale Fuels FIRE CHIEF P.O. Box 82277 Ro~ FROZE Bakersfield CA 93380-2277 ADMINISTRATIVE SERVICES 2101 "H" Street RE: Upgrade Certificate of Compliance and Fuel Tags Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661 ) 395-1349 Dear Fuel Vender: SUPPRESSION SERVICES 2101 "H' Street Please be advised effective January 1, 2003 AB2481 deletes thc Bakemfield, CA 93301 vo~c~ (661) 326-3~1 requirements for both upgrade compliance certificates and fuel fill FAX (661) 395-1349 tags. PREVENTION SERVICES s,~, sE.~Es.~o.,~.~,~sE.~s Underground storage tank fuel facilities have been notified of the 171s Chest,,rAve. change. Customers have the option of leaving the fill tags and Bakersfield, CA 93301 VOICE (661) 326-3979 certificate in place, but can remove it if they wish. FAX (661) 326-0.576 PUBLIC EDUCATIO. Should you have any questions, please feel free to contact me at 661- 17 is chester Avi,. 326 -3190. Bakersfield, CA 93301 VOICE (661) 326-3696 FIRE INVESTIGATION 1715 Chester Ave. :" Bakersfield, CA 93301 VOICE (661) 32S-3951 FAX (661) 326-0576 Steve Underwood TRAINING DIVISION Fire Inspector/Environmental Code Enforcement Officer ,~c,42 wctorAve. Office of Environmental Services Bakersfield, CA 93308 VOICE (661)399-4697 FAX (661) 399-5763 S B U/dc D /. January 17, 2003 Wholesale Fuels FIRE CHIEF P.O. Box 70097 RON FRAZE Bakersfield CA 93387-0097 ADMINISTRATIVE SERVICES 2101 'H" Street Bakersfield, CA 93301 RE: Upgrade Certificate of Compliance and Fuel Tags VOICE (661) 326-3941 FAX (661 ) 395-1349 Dear Fuel Vender: SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 Please be advised effective January 1, 2003 AB2481 deletes the VOICE (661) 326-3941 requirements for both upgrade compliance certificates and fuel fill FAX (661) 395-1349 tags. PREVENTION SERVICES FIRE SAFETY SERVICES · ENVIRONtJENTAL SERVICES 1715 ChesterAve. Underground storage tank fuel facilities have been notified of the Bakersfield, CA 93301 change. Customers have the option of leaving the fill tags and VOICE (661) 326-3979 FAX (661) 326-0576 certificate in place, but can remove it if they wish. PUBLIC EDUCATION 1715 ChesterAv~e. Should you have any questions, please feel free to contact me at 661- Bakersfield, CA 93301 326-3190. VOICE (661) 326-3696 FAX (661) 326-0576 FIRE INVESTIGATION SiT'~ 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (664) 326-O576 Steve Underwood - - - TRAINING DIVISION Fire Inspector/Environmental Code Enforcement Officer 5642 Victor Ave. Bakersfield, CA 93308 Office of Environmental Services VOICE (661) 399-4697 FAX (661) 399-5763 SBU/dc L D January 13,2003 Wholesale Fuels P. O. Box 82277 Bakersfield CA 93380-2277 FIRE CHIEF RON FRAZE RE: Deadline for Dispenser Pan Requirements December 31, 2003 ADMINISTRATIVE SERVICES 2101 "H' Street Bakersfield, CA 93301 VOICE (661) 326-3941 REMINDER NOTICE SUPPRESSION SERVICES 2101 ~H' Street Dear Tank Owner: Ba~rs,~, c^ 9~301 unaergrouna ~torage VOICE (661) 326-3941 FAX (661) 395-1349 A review of our files indicates that you have been receiving quarterly PREVENTION SERVICES reminder notices since April of 2002. FIRE SAFETY SEIWlCES, ENYIROHMEh'TAL S~RVICES 1715 Chester Ave. Bakersfield, C^ 93301 The purpose of this letter is to remind you of the necessary retrofit of VOICE (661) 326-3979 FAX (661) 326-0576 your fueling system. Current code requires that you install dispenser pans prior to December 31, 2003. I urge you to start planning to retrofit PUBLIC EDUCATION 1715 ChesterAv'e. your facility as soon as possible. Bakersfield, CA 93301 VOICE (661) 326-0696 FAX (661)326-0576 Should you have any questions, please feel free to contact me at 661- 326-3190. FIRE INVESTIGATION 1715 Chester Ave. Bakersfield, CA 93301 Sincere] y, VOICE (661) 326-3951 TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 Steve Underwood VOICE (661) 399-4697 FAX (661) 399-5763 Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/dc CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3rd Floor, Bakersfield, CA 93301 FACILITY NAME ~l}~/~le,~le.. ~"Oe.l~ INSPECTION DATE i~ '~ .'.'5 'O -?-. Section 2: Underground Storage Tanks Program [] Routine [~1 Combined [] Joint Agency [] Multi-Agency [] Complaint [] Re-inspection Type of Tank 6tO/... Number of Tanks ~ Type of Monitoring .g.T~, Type of Piping ,qtO~q OPERATION C V COMMENTS Proper tank data on file Proper owner/operator data on file Permit tees current Certification of Financial Responsibility Monitoring record adequate and current Maintenance records adequate and current Failure to correct prior UST violations Has there been an unauthorized release? Yes No Section 3: Aboveground Storage Tanks Program TANK SIZE(S) AGGREGATE CAPACITY' Type of Tank Number of Tanks OPERATION Y N COMMENTS SPCC available SPCC on file with OES Adequate secondary protection Proper tank placarding/labeling Is tank used to dispense MVF? If yes, Does tank have overfill/overspill protection? C=Compliance V=Violation Y=Yes N=NO Inspector: :j/~ ~/~ ~ Omce of Environmental Services (805) 326-3979 /Busin.,0~ Siie Responsible Party White - Env. Svcs. Pink - Business Copy CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3ra Floor, Bakersfield, CA 93301 FACILITY NAME b0{~{t-s~{~ ~"~S INSPECTION DATE {~- ~,:3~)3.. ADDRESS ~a{')~ E. O~tO~t[a,a {/~ PHONE NO. 30'1' q?CYt3 FACILITY CONTACT BUSINESS ID NO. 15-210- INSPECTION TIME NUMBER OF EMPLOYEES Section 1: Business Plan and Inventory Program I~ Routine ~l Combined [~ Joint Agency ~} Multi-Agency ~.~ Complaint [~ Re-inspection OPERATION C V COMMENTS Appropriate permit on hand Business plan contact information accurate Visible address Correct occupancy Verification of inventory materials Verification of quantities Verification of location Proper segregation of material Verification of MSDS availability Verification of Haz Mat training Verification of abatement supplies and procedures Emergency procedures adequate Containers properly labeled Housekeeping Fire Protection Site Diagram Adequate & On Hand C=Compliance V=Violation Explain:Any hazardous waste on site?: [~] Yes [~] No White - Env. Svcs. Yellow - Station Copy Pink - Business Copy nspecto: December 1, 2002 Wholesale Fuels P O Box 82277 Bakersfield CA 93380 2277 FIRE CHIEF RON FRAZE CERTIFIED MAIL ADMINISTRATIVE SERVICES 2101 'H' Street Bakersfield, CA 93301 VOICE (661) 326-3941 ~^x iOOl)395-1~n~ FINAL REMINDER NOTICE suP.RESS,O. SE.V,CES JANUARY 1, 2003 DEADLINE Bakersfield, CA 93301 vo,cE (66,)~26-394, ~Z Z-CO0 Ty.. ua FAX (661) 395-1349 Dear Tank Owner/Operator: PREVENTION SERVICES ,,,~,s~Es.,~o,.,,~,,,..~,,,:,, You will be receiving this letter on or about December l, 2002. One 1715 Chester Ave. Bakersfield, CA ~m01 month from today, January 1, 2003, your current underground VOICE (661) 326-3979 FAX (661) 326-0576 storage tank(s) will become illegal to operate. Current law would require that your permit be revoked for failure to perform the PUR,,C EDUCATIOn necessary Secondary Containment testing. 1715 Chester Avb. Bakersfield, CA 93301 VOICE (661) 320-3696 FAX (661)326-0576 In reviewing your file, I see that you have received "Reminder Notices" since April of this year. This is your last chance to comply F,RE,NVESTIC~TION with code requirements for Secondary Containment testing prior to 1715 Chester Ave. Bakersfield, CA 9..3,301 January 1, 2003. VOICE (66.1) 326-395'1 FAX (661) 326-0576 Should you have any questions, please feel free to contact me at 661- TRAINING DIVISION 326-3190. 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 -- -.,Rincerelv, FAX (661) 399-5763 Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/dc D September 30, 2002 Wholesale Fuels P O Box 82277 Bakersfield CA 93380-2277 RE: Deadline for Dispenser Pan Requirement December 31, 2003 FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES REMINDER NOTICE 21ol "H' Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 Dear Underground Storage Tank Owner: SUPPRESSION SERVICES 2101 ~H' Street Bakers~eld, C^ 93001 YOU will be receiving updates from this office with regard to Senate Bill VOICE (661)326-3941 989 which went into effect January 1, 2002. FAX (661)395-1349 PREVENTION SERVICES This bill requires dispenser pans under fuel pump dispensers. On SAFETY SERI,lCES * ENVIRONM'rNTN. SERYICE$ 1715 Chester^vs. December 3 1, 2003 which is the deadline for compliance, this office will Bakersfield, CA 93301 be forced to revoke your Permit to Operate, for failure to comply with the VOICE (661) 326-3979 (661) 3260576 regulations. PUBLIC17t 5 ChesterEDUCATIONAvb. It is the hope of this office that we do not have to pursue such action, Bakersfield, CA 93301 which is why this office plans to update you. I urge you to start planning vOiCE (66t) 326-3630 FAX (661) 326-0576 to retro-fit your facilities. FIRE INVESTIGATION If your facility has been upgraded already, please disregard this notice. 1715 Chester Ave. Bakersfield, CA 93,301 Should you have any questions, please feel free to contact me at 661-326- VOICE (661) 326-a951 FAX (661) 326-0570 3190. TRAINING DIVISION Sincerelv~ 5642 VlctorAve. ~ ~ Bakersfield, CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/dc .<:i D.9/28/01 07:45 9661 0576 BFD HAZ 3IAT DIV ~002 MONITORING SYSTEM CERTIF!CAI"ION For L'se By All Juri.vdic't~,.s Wit/tin the 3'late qf C'al~forniu[ Authority Cited: Chapler 6.7. Health and Sq/kCv Code: Cimprer 16. Div. ision 3. Title 23. ~al~Jrnia Code of Re.qulations . This term must be used to document testin~ and se~icing of monitorin~ equipment. A separate ceCfification or report ~ust be prepared r'or each monitoring s~stem control ~gj~e~ by the technician who performs thc work. A copy of [fils. tbrm must be provided ~o the tank system owner/operator. The owner/operator must submit a copy et' this tb~ re the local agen{y regulating UST systems within 30 days of test date. A. General Informatlon~ . Facility Name: ~~'~ ~C .~ Bldg. No.:.. Facility Comact Person:~~~~/ Contact Phone N'~,: (~) ~ Date of ~esdng/Se~ici,w: Make. oriel of Monitoring System: .~g~ ~-~ <SS~ / B. Inventory of Equipment Teste~Certified ~;'<~e° Check the apprOpriate boxes to indieam .... s~eeifie ...... e.~dpment ~speete~se~iceq:, ,, ....... Tank ~: / ~ Tank ID: ~ In-Tank Gauging Probe. Model: _~ [ ~[n-Tank Gauging Probe. Model: '2 .~nul~ Space or Vault Sensor. Model: ~ Annut~ Space or Vault Seas ~r. Model: O Piping Sump / Trench Senso~s). Model: ~ Piping Sump / Trench Senso~ <s). Model: ~ Fill Sump Scarer(s). M~el: ~ Fill Sump Sensor(s). [ Model: ~ Mechanical Line Le~ Detector, Model: ~ Mech~ical Line Leak Detec{or. Model:' '~ Electronic Line Leak Detector. Metier: [~' ~OO ~ Elec=onic Line ~ Detecto{r. Model: _ ~0 / .~ ~ Tek Ove~511 / High-Level S~nsor. Model: ~1~[ ~rank Overfill/High-Level Sensor. Model: ~.. ~ Other (specify equipment t~e ~d model in S~ction E on Pa~e 2). , ,~ Other (s~cify equipment,t~ ~d model in Section E on Pa~e 2). Tank m: 2 ~/ Ta~ m: O I ~ [n-Tank Gaugihg Probe. Model: · In-Tm~k Gauging ~obe. ] Model: ~ ~mul~ Space or Vault Sensor. Model: ~ Annul~ Space or Vault Sens~r.. Model: ' ~ Piping Sump / Trench Sensor(s). Model: ~ Piping Sump / Trench Sensor, s). Model: ~ ~ Fill Sump Sensor(s). M~el: ~ Fill Sump Sensor(s). / Model: ~ Mechanical Line Le~ Detector. Model: ~ Mechanical Line Le~ ~tectOr. M~el: ~ glecgonic Line Le~ Detector. Model: ~ ,~ . ~ Elec=onic Line ~ Detecto}. Model: ~ Taak Ore, Il/High-Level Sensor. Model: ~~ ~ ~ Tank Ove~ll / Hi~h-Leve! S~nsor. Model: ~ Other (s~cifv equipment type and model in Section E on Page 2). D Qt)e[ (speci~ eq~pment typ~ and mgdel in Section E on Pa~e 2). Dlspemer ID: ~o~ Dis~nser ID: . ~[~,i~ff I ~ Dispenser Cont~nment Sensor(s). Model: ~ Dispenser Comainrnent SensOr(s). Model: ~ She~ V~ve(s). ~ Shear Valve(s). ~ Dispenser Containment ~oat(s) and Chain(s). ~ Dispenser Cont~nment FloatOs) ~d Chain(s,). Dis~nser ID: ~~ . . ~ Dispenser ID: ~ Dispenser Containment Sensor(s). Model: ~ Dispenser Containment SensOr(s). Model: ~ Shear Valve(s). ~ Shear Valve(s). ~ Dispenser Con?.i.~{nent ~oat(s) and C)a{~(s). ~ Dispenser Containment F oat(s) and Chain(s). Dispenser ID: ~~,~ ........ 2. D'tspenser ID: ensorl s 5lodel ~ Dispenser Containmem Sensor(s). Model: _ ~ Dispenser Conm5nment S ('). :' ~ Shear X.'alve(s~. ~ Shear Valve,s). / m' ~Dispenser Coh;ainment Ftoat(s) and Clmin(s). ~ Dispenser Ccntmnment Float0) and Cha' ts). qf the facili~ contains more tanks or dispensers, copy this fo~. Include info~mtion for every ~k and dispenser atthe hcility. C. Certification. I cem~ that the ~uipment iden6~ in ins document w~ lmp~anse ~ith the m~ufac~em' g~gdelin~. Attached to this Ce~fication is iffomfion (e.g. mnufacmrem' che~ neees~ to~tNs I~ommtion is correct and a Plot Plan showing the layout of moffito~ng eqffipment. For any e~en~ting such }ep~r~,~.l have also attached a copy of the reuo~; (check all~RE¢): ~System set-up ~la~ory[ report Technician N~ne (print): ~~ _~~~[ Sigaatur~_~~, ~ .... TestingCompang~me: ~~='r ~~<~ ~ Phone No.:(~(_) ~fl'~' Page I of 3 03101 Monitoring 'System Certification 0~/28/01 07:46 9661 6 0576 BFD HAZ ~IAT [~003 D. Results of Testing/Servicing Sofm, are Version Installed: ~,~,/' Corn)leto the following checklist; . ,, ~ Yes ' i ~ N~*' ! Is the audible alarm operatiolml?' ~ Yes ~ No.~ I Is the visual alarm operatiogal.?' . . ~ ..... ~1 Yes ~ No* Were all sensors.yisu, ally inspected, t'uncfionalty.~_~t.ed..and confirm'ed ope,.ratiopal? - '~ YeS ..... ~ ~'o* Were ail sensors installed at lowest point of secondary containment and positioned so that other equipme'nt will I not interfere with their prier qperat/on? ~ Yes 'Zl No* I If alarms are relayed to a remote monitoring station, is all communications equipment '(e.g. modem) 1~ N/A operational? ~ Yes IZl No* ' For pressurized piping systems, does the turbine auiomatical'ly *hut do~'n 'if the pipiflg secondary containment IR N/A I monitoring system detects a leak, i~ails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) ifll Sump/Trench Sensors; ~ Dispenser Containment Sensors. Did you. confirm positive, shut-.down, due to leaks an,_~d sensor failure/disconnectionS. IZl Yes; F1 No. . . ~' Yes ~ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. nO 'lYi~N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fiH point(s) an_..dpPerating properly'? If so, at?ha.[ percent of tank capacity does the alarm trigger? ~1 Yes* tlg} N'o Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and l!$t !he ma..nPfactgrer name and mode. l for all replacement parts in Section E, below. ~ Yes* t~' No Was'liquid found inside any secondary, containment systems des~.gned as dry systems? (~heck all that ~pply) [2] Pro..du?.;. Q Water. If ye~, describe causes in Section E,..below. '~[~ Yes ~ NO, W.a.s monitoring system set-up.reviewed to ensure pr°per, set.[in~s? Attach set_ UP rep°rts, if applicable ~.~ Yes ~1 No* i Is at1 monitoring_equipment operational per manufacture['s s?ecifi.ca, ticms? ..... · In Section E below, describe how and when these deficiencies were or will be corrected, Page 2 of 3 03/0 t ,09/28/01 07:47 ~'~661 0576 BFD HAZ ~iAT DIV /~004 F. In-Tank Gauging / SIR Equipment: ~ Check this box it' tank gauging is used only l'br inventory control. ,'3 Check this box if no tank gauging or SIR equipment is installed. ' This section must be completed it' in-tank gauging equipment is used to perform leal< detection monitoring. Complete the following checklist: ...... · . . i~,/~,' Yes. 'C] No* I Has 'ail. input wiring been__inspected f6r proper onto' and terminati~"]~"cluding, testing for grou'nd. ~faults'"' ..... ~ Yes I ~ No* I Were all tank gaugin probes visually inspected for damage and residue buildup'~ i~ . · . .au~~al.ty tnspecteo tot aal ........... r. . ~ Yes r..3 No Was accuracy of system product level readings tested'~ Il ~ Yes / ~1 iX/o* / Were all probes rei'nstalled properly'? -- Yes ~1 No* Were all items on the e ui ment manufacturer's maintenance checklist completed? . / ... / ...... ', .q,p - ', .... ___.. ..... · In the Section H, below, describe h0w'and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): ~ Check this box it' LLDs are not installed. Corn leto the following checklist: Yes [1 No* For equipment start-up or annual equipment certification, was a leak simulated t° verify LLD performance? ~ N/A (Check all that apply) Simutated teak rate: ~3g.p.h.: i~10.1g.p.h; L.-.-10.2g.p.h. (t~ '~es ~ No* Were all LLDs confirmed operational m~d accurate'within'regulatory requirements.'j ..... .~Yes ~1 No* W'as. the testing ap3aratus properly calibrated? ~ Yes ~ No* ~; mechanical LLDs, does the LLD restrict product flow' if it.detects a leak'? 2 N/A' 129 Yes ~ No* ~'~,3' electronic LLDs, does the't'urbine automaticali½';hut off if the LLD d~tects a i~ak? ~ N/A /~ Yes ~ No* For electronic LLDsl does the turbine"automatically shut off if any portion of i'Ve monitoring system is disabled ~ N/A or disconnected? i/~ Yes i~l No* For electronic ELDs, does the turbine a'utomatically shut off if any portion of the rn~>nitoring system malfunctions t--} N/A or fails a test'? ~ 'Yes 13 No*, For electronic LLDs, have all accessible wiring conn'ections been visualiY inspecte"~'~ " . ~ N/A ] ~ Yes. . "-I'. ....... No*...[ ..Were ..... al/, items on ...... the equipment manut~'turer's"r~aint'enance checklist.,completed? .... · In the Section H, below', describe how and when. these detlctencies were or will be corrected. H. Comments: Page 3 of 3 03/01 Monitoring System Certification ...UST Monitoring Site Plan ~ ~ ~ ~ ~ ~ ~ "~ ~ "~~ ....'.' .... ~'': .... ~'~:" :.':.'' ~.'.~ ~'~. '. 2 ~"..'~ ~ ~ ~ ::::: :~¢~4::::::::::::: :.: :.;:::: :' :"::::' ":' """ ...... .. Date ~p was ~a~: Instruct[on~ ., hav a dia am ~at shows all re' Uired infomation, ~°U may"ih~lude 'it,.miher'~an'~s ~hg'e, M~ yo~ If you already e ~ ............ q ........................ . ......... ~:.~ ;.~.~ .... .~...~. .... ¥.... ,:..::~..~...::,~:.,~..~;~ ,;, ,,:?'.'; .... MonitOring sys~em'.c'~i'ficla~a(~:::` m yo~ site :~]ah; shOW m~'~en~rfil la~ofit '6f t~' =d 'p~p~ng. :.:...c~e~ty menuw locations, of ~e foliO~ng eqUipment, if installed:'/'~;nit°fing:s~tem ~3(:~'i~?~3~ '~i66'~'~ ~u~ spaces, sump'~, di~efiser panS; spill containers,: Or'other S&'c°nda~ e0nmi~{nt .~reas:, mechahical Or'"eleC~onic .line leak detectors; and in-tank liquid level probes (if used 'for leak detection), h ~'6 ~aee pr6~ded, nOte vv~re~are& . . ...... .. ~'~ '.:.).'..:'~'.L'7:'" "": .... ":"" .... '" ~''' was '" .: ... .... ' ~:'.'::. '.. '..?' ,.'2v.."'r:, ' ~ 'r ~ "'"":~' i ......... ' SYSTEM SETUP VOLUME = 2786 GALS OLESAL.E F/iEL ULLAGE = 17777 GALS ]0 E BRUNDAGE LN SEP 20, 2002 1:38 PM 90~ ULLAGE= 15720 GALS ~ERSFIELD CA TC VOLUME = 2724 GALS 98304 HEIGHT = 28.18 INCHES WATER = 0.00 INQHES SEP 20.. 2002 1:40 PM ENGLISH TEMP = 91.7 DEC F U.S. WHOLESALE FUEL T 5:DYED DIESEL SYSTEM STATUS REPORT 2200 E BRUNDAGE LN VOLUME = 1866 GALS ........ BAKERSFIELD OA ULLAGE = 19197 GALS 90~ ULLAGE= 17140 GALS T 6:HIGH LIMIT ALARM 93804 TO VOLUME = 1844 GALS SHIFT TIME 1 : 12:00 AM HEIGHT = 14.17 INCHES SHIFT TIME 2 : 4:00 AP1 WATER = 0.00 INCHES SHIFT TIME 8 :' 7:00 PM TEMP = 95.6 DEC F 'WHOLESALE2200 E BRUNDAGEFUEL LN BAKERSFIELD CA SYSTEM SEOURITY 93804 CODE : 000000 T 6:EPA DIESEL VOLUME = 19826 GALS SEP 20, 2002 1:40 PM ULLAGE = ,737 GALS 90~ ULLAGE= 0 GALS TC VOLUME = 19603 GALS HEIGHT =110.69 INCHES SYSTEM STATUS REPORT WATER = 0.00 INCHES ...... , TEMP = 85.0 DEC F ~- T 6:HIGH LIMIT ALARM '- T 7:EPA 2 VOLUME = 8520 GALS INVENTORY REPORT COMMUNICATIONS "SETUP ULLAGE = 12043 GALS ....... = .... 90~ ULLAGE= 9986 GALS NONE FOUND ' TO VOLUME = 8425 GALS T i:L-S D~=S~l'-=~ GALS HEIGHT = 51.90 INCHES VOLUME - 6949 GALS R8-282 SECURITY WATER = 0.00 INCHES ULLAGE - CODE : 0000~0 TEMP = 84.6 DEC F 90% ULLAGE= 5949 GALS '' TO VOLUME = 8005 GALS ~ HEIGHT = 32.71 iNCHES T 8:E.P.A. DIESEL WATER , 0.00 iNCHES ~ = 93.1 DEC F VOLUME = 9377 GALS TEMP ULLAGE = 2623 GALS 90~ ULLAGE= 1428 GALS TC VOLUME = 9286 GALS T 2:PREM UNLEADED = 2540 GALS HEIGHT = 70.0! INCHES VOLUME = 7460 GALS WATER = 0.00 INCHES ULLAGE TEMP = 81.4 DEC F 90%~ ULLAGE= 6460 GALS TC VOLUME = 2479 GALS IN-TANK SETUP HEIGHT = 28.64 INCHES 0.00 INCHES TEMP T i:L-S DIESEL T 3:CLEAR DIESEL VOLUME == 12745 7818 GALS GALS PRODUCT CODE 1 ULLAGE THERMAL COEFF .000450 90%~ ULLAGE= t06BB GALS TANK DIAMETER 95.00 TO VOLUME = 7698 GALS HEIGHT = 48.64 INCHES TANK PROFILE : 1 PT WATER = 0.00 INCHES FULL VOL : 10000 TEMP = 9~.9 DEG F HIGH WATER LIMIT 4.0 OVERFILL LIMIT 95% -9500 HIGH LEVEL LIMIT: 95% : 9500 LOW LEVEL LIMIT 500 LEAK ALARM LIMIT 75 THEFT LIMIT 100 TANK TILT 2.40 MANIFOLDED TANKS TANK~: NONE DELIVERY DELAY : 1MIN T ~:PREM UNLEADED ~RODUOT OODE 6 PRODUCT CODE 4 t~_ THERMAL COEFF .000450 THERMAL COEFF .000700 RODUCT CODE 2 TANK DIAMETER 120,00 TANK DIAMETER 120,00 THERMAL COEFF ,000750 TANK DIAMETER 95,00 TANK PROFILE : I PT TANK PROFILE : 1 PT FULL VOL ; 20563 FULL VOL : 20563 TANK PROFILE : 1 PT FULL VOL : lOOOO HIGH WATER LIMIT 4,0 HIGH WATER LIMIT 4,0 OVERFILL LIMIT 95~ OVERFILL LIMIT 95~ HIGH WATER LIMIT 4.0 19535 19535 OVERFILL LIMIT 95% 9500 HIGH LEVEL LIMIT: 95N HIGH LEVEL LIMIT: 95% : 19505 : 19535 HIGH LEVEL LIMIT: 95% : 9500 LOW LEVEL LIMIT 500 LOW LEVEL LIMIT : 500 LEAK ALARM LIMIT 75 LEAK ALARM LIMIT: 75 LOW LEVEL LIMIT : 500 THEFT LIMIT 100 THEFT LIMIT : 100 LEAK ALARM LIMIT: 75 TANK TILT 2.00 TANK TILT : 0.00 THEFT LIMIT 100 TANK TILT : 2.95 MANIFOLDED TANKS MANIFOLDED TANKS TANK~: NONE TANK~: NONE MANIFOLDED TANKS TANK~: NONE DELIVERY DELAY : 1MIN DELIVERy DELAY : 1MIN DELIVERY DELAY : 1MIN T 7:EPA 2 T 5:DYED DIE~EL T 3:CLEAR DIESEL PRODUCT CODE : 7 PRODUCT CODE : 5 THERMAL OOEFF :,000450 THERMAL COEFF :,000450 PRODUCT CODE : 3 TANK DIAMETER : 120,00 TANK DIAMETER : 120,00 THERMAL COEFF :,000450 TANK DIAMETER : 120,00 TANK PROFILE : 1 PT TANK PROFILE : 1 PT FULL VOL .: 20563 FULL VOL : 20563 TANK PROFILE : 1 PT FULL VOL : 20563 HIGH WATER LIMIT: 4,0 HIGH WATER LIMIT 4,0 OVERFILL LIMIT : 97~ OVERFILL LIMIT 95% HIGH WATER LIMIT 4,0 : 19946 19535 OVERFILL LIMIT 95~ 19535 HIGH LEVEL LIMIT: 99~ HIGH LEVEL LIMIT: 95~ : 20357 : 19535 HIGH LEVEL LIMIT: 95~ : 19535 LOW LEVEL LIMIT : 500 LOW LEVEL LIMIT 500 LEAK ALARM LIMIT: 75 LEAK ALARM LIMIT 75 LOW LEVEL LIMIT : 500 THEFT LIMIT : 100 THEFT LIMIT 100 LEAK ALARM LIMIT: 75 TANK TILT :- 2,00 TANK TILT 0.00 THEFT LIMIT : 100 TANK TILT : 0.50 MANIFOLDED TANKS MANIFOLDED TANKS TANK~: NONE TANK~: NONE MANIFOLDED TANKS TANK~: NONE DELIVERY DELAY : 1MIN DELIVERY DELAY : 1MIN DELIVERY DELAY : 1MIN ALARM HISTORY REPORT Ll~UlO ~N~OK ~ETUP T 8:E.P.A, DI~L PAPER OUT PRODUCT¢ODE 8 THERMAL OOEFF .000450 SEP 17, 2002 10:45 AM NONE TANK DIAMETER 96.00 PRINTER ERROR SEP 17, 2002 10:45 AP1 TANK PROFILE : 1 PT BATTERY IS OFF FULL VOL : 12000 JAN I, 1991 8:00 APl HIGH WATER LIMIT 2.0 OVERFILL LIMIT 95~ 11400 HIGH LEVEL LIMIT: 95~ : 11400 VAPOR SENSOR SETUP LOW LEVEL LIMIT 100 LEAK ALARM LIMIT 99 THEFT LIMIT 99 ALARM HISTORY REPORT NONE TANK TILT 5.00 TANK NUMBER 1 L-S DIESEL MANIFOLDED TANKS TANK;: NONE HIGH WATER ALARM DELIVERY DELAY : 15 MIN MAY 26, 2002 6:49 AM JUL 1, 200C 9:51 PM OVERFILL AL~M MAY 27. 2002 7:12 AM FEB 4, 2002 11:87 AM FEB 4. 2002 11:85 AM GROUNDWATER SETUP HIGH LIMIT ALARM .. MAY 27, 2002 7::~-AM NONE FEB 4, 2002 9:01 AM SEP 9, 2001 J:lO PM INVALID Fu~L LEVEL LEAK TEST METHOD AUG I?, 2002~i0:4~ AM JUN 28,' 2002 i:2J PM TEST MONTHLY : ALL TANK MAR 14, 200~ 10:00 APl WEEK 1 SUN PROBE OUT START TIME : 2:00 AM REPORT RATE: 0.2 GAL/HR FEB 4, 2002 11:35 APl DURATION : 2 HOURS FEB 4, 2002 ll:~S AM FEB 4, 2002 11:28 AM EXTERNAL INPUT SETUP NONE OUTPUT RELAY SETUP R i:POS EPA IN-TANK ALARMS T 7:OVERFILL ALARM T 7:HIGH LIMIT ALARM R 2: - NO ALARM ASSIGNMENTS - R J: - NO ALARM ASSIGNMENTS - R 4: - NO ALARM ASSIGNMENTS - ALARM HISTORY REPORT ALARM HISTORY REPORT TANK NUMBER 6 EPA DIESEL TANK NUMBER 2 LEAK ALARM ALARM HISTORY REPORT PREM UNLEADED JUN 3, 2001 4:00 AM TANK NUMBER 4 HIGH WATER ALARM NOV 5, 2000 3:30 AM UNLEADED FEB 11, 2002 ii:OS AM SEP 23, 2000 5:08 PM HIGH WATER ALARM OVERFILL ALARM FEB 23, 2002 3:32 PM OCT 14, 2000 3 41 PM OVERFILL ALARM FEB 23, 2002 3:28 PM OCT 6, 2000 10 02 AM AUG 22, 2000 7:30 PM JAN 2?, 2002 9:18 PPI AUG 20, 2000 6 40 PM JUL 1, 2000 1:15 PM DEC 16, 1999 2:34 PPi OVERFILL ALARM HIGH LIMIT ALARM SEP 16, 2002 1:56 AM DEC 3, 2000 8 52 PM HIGH LIMIT ALARM JUL 9, 2002 12:14 PM OCT 14, 2000 3 4i PM AUG 22, 2000 7:30 PM JUL 8, 2002 I:07 PM OCT 6, 2000 10 02 AM JUL 1~ 2000 1:15 PM DEC I6. 1999 2:35 PM THEFT ALARM INVALID FUEL LEVEL JUN 3, 2001 3:31 AM SEP 11, 2002 12 32 PM INVALID FUEL LEVEL NOV 5, 2000 2:59 AM AUG 14, 2002 5 53 AM SEP 5, 2002 6:12 AP; JUL 15, 2002 4 37 AP1 JUL 20, 2002 10:07 AM HIGH LIMIT ALARM MAY 6, 2002 6:31 AM SEP 16, 2002 1:56 APl JUL 8, 2002 1:08 PM APR 21, 2082 3:29 PM INVALID FUEL LEVEL SEP 12, 2001 5:29 PM AUG 31, 2001 3:23 AM JUL 11, 2001 8:26 PM ........ PROBE OUT ALARM HISTORY REPORT NOV 11, 2001 10:28 AM ALARM HISTORY REPORT NOV 11, 2001 10:25 AP1 TANK NUMBER 5 SEP 13, 2001 1:37 PPi DYED DIESEL TANK NUMBER 3 CLEAR DIESEL HIGH WATER ALARM SEP 18, 2002 1:19 PM HIGH WATER ALARM SEP 10, 2002 2:27 PM SEP 19, 2002 11:00 AM SEP 9, 2002 3:14 PM SEP 18, 2002 12:09 PPi SEP 18, 2002 11:58 AM OVERFILL ALARM SEP 3, 2002 3:44 PM OVERFILL ALARM AUG 29, 2002 5:23 AM AUG 25, 2002 2:22 PM AUG 27, 2002 4:09 PM JUL 14.. 2002 12:16 PM APR 2, 2002 9:27 AP1 LOW LIMIT ALARM JUL 7, 2000 2:01 PM HIGH LIMIT ALARM AUG 25, 2002 2:22 PM HIGH LIMIT ALARM JUL 14, 2002 12:17 PM SEP 3, 2002 3:44 PM APR 2.. 2002 9:27 AM AUG 29, 2002 5:23 AP1 AUG 27, 2002 3:23 PM INVALID FUEL LEVEL SEP 12, 2002 2:08 PM INVALID FUEL LEVEL~ SEP lO, 2002 3:48 PM AUG 15, 2002 11:22 mM SEP 6, 2002 11:47 AP1 AUG 7, 2002 3:40 PM AUG 4, 2002 1:41 PM PROBE OUT SEP 18, 2002 12:00 PPi PROBE OUT SEP 10, 2002 4:11 PM SEP 18, 2002 .1:19 PM SEP 10, 2002 3:53 PM SEP 10, 2002 2:21 PM SEP 9, 2002 3:16 PM TANK 7 EPA 2 LEAK ALARM ALARM HIBTORY REPORT APR 1, 2001 3 30 AM FEB 4, 2001 4 00 AM TANK NUMBER 8 OOT 1 2000 3 30 AM E.P.A. DIESEL ' HIGH WATER ALARM LEAK ALARM AUG 29, 2001 6 13 APl JUN 3, 2001 3:30 AM JUN 10, 2001 9 43 PM NOV 5, 2000 4:00 AM FEB 14, 2001 4 42 PM HIGH WATERALARM OVERFILL ALARM FEB 12, 2002 5:23 PM SEP 6, 2002 9:58 PM JAN 24, 2002 7:06 PM SEP 3.. 2002 5:20 APl JUL 18, 2001 6:17 PM AUG 30, 2002 2:11 AM OVERFILL ALARM LOW LIMIT ALARM FEB 10, 2002 9:09 PM AUG 31, 2002 12:43 PM FEB 5, 2002 8:08 PM AUG 21, 2002 8:54 AM JAN 27, 2002 11:52 PM AUG 15, 2002 7:15 AM. THEFT ALARM THEFT ALARM JUN 3, 2001 9:23 APl SEP 2, 2001~ 8:59 AM NOV 5, 2000 3:54 APl APR 1, 20Q1 3:20 AM HIGH LIMIT ALARM FEB 4, 2G01 3:36 AM FEB 10, 2002 9:09 PM HIGH LIMIT ALARM FEB 5, 2002 8:08 PM OOT 20, 20OO 5:97 AM JAN 27, 2002 11:52 PM OOT 19, 2000 4:53 AM INVALID FUEL LEVEL OOT 13, 2000 4:13 AM SEP 16, 2000 9:57 AM INVALID F~EL LEVEL JUN 29, 2002, 1:18 PM PROBE OUT JUN 19,. 2002 3:18 PM APR 1, 2801 9:26 PM JUN 2, 2002 3:36 PM DEO 27, 1999 10:10 AM PROBE OUT FEB 14, 2001 4:38 PM DEC 26, 2000 3:59 PM DEC 26, 2000 3:57 PPl L D September 13, 2002 2200 E Brundage Lane ~ , · ~>( ~ -~ ~ Bakersfield CA 93307 CERTIFIED MAIL FIRE CHIEF NOTICE OF VIOLATION & SCHEDULE FOR COMPLIANCE RUN FRAZE · ADMINISTRATIVE SERVICES 2101 Street RE: Failure to Submit/Perform Annual Maintenance on Leak Detection System Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 39s-f 349 Dear Underground Storage Tank Owner: SUPPRESSION SERVICES 2101 "H" Street Bakersfield. CA 93301 Our records indicate that your annual maintenance certification on your leak detection VOICE (661) 326-3041 FAX (661) 39S-t3~9 system is past due on September 27, 2002. ~'REVE"T~ON SERVICES You are currently in violation of Section 2641(J) of the California Code of t 715 Chester AYe. Reeulations. Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 326-0576 "Equipment and devices used to monitor underground storage tanks shall be installed, calibrated, operated and maintained in accordance with manufacturer's instructions, PUBLIC EDUCATION 1715 ChosterAvb. including routine maintenance and service checks at least once per calendar year for Sakersf~e~d, Ca 93301 operability and running condition." vOiCE {661) 326-36~ FAX (661) 326-0570 You are hereby notified that you have thirty (30) days, October 13, 2002, to either FIRE INVESTIGATION perform or submit your annual certification to this office. Failure to comply will result 1715 C,ester^ve. in revocation of your permit to operate your underground storage system. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661)326-0576 Should you have any questions, please feel free to contact me at 661-326-3190. TRAINING DIVISION 5642 Victor Ave. Sincerely, Bakersfield, CA 93306 VOICE (661) 399-4697- FAX (661) 399-5763 Ralph Huey Director of Prevention Services Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services cc: Walter H. Purr Jr., Assistant City Attorney r~ Postage $ r~ r-t Certified Fee Postmark Return Receipt Fee r'-t (Endorsement Required) Here . ~3 Restricted Delivery Fee t-1 (Endorsement Required) ' I'lJ Total Postage & Fees ~ [~[ ,Wholesale Fuels Inc /~;;~;~'~£'/~;~ ............................................................................. [or /=O ~ox No. 2200 E Brundage Lane ai/~;; ~ iET~£.~,-;i ........................................................................... / Bakersfield CA 93307 September 13, 2002 Wholesale Fuels Inc. 2200 E Brundage Lane Bakersfield CA 93307 CERTIFIED MAIL F~RE CHIEF NOTICE OF VIOLATION & SCHEDULE FOR COMPLIANCE RON FRAZE ADMINISTRATIVE SERVICES 2101 ~H~ Street RE: Failure to Submit/Perform Annual Maintenance on Leak Detection System Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (601) 395-1349 SUPPRESSION SERVICES Dear Underground Storage Tank Owner: 2101 "H' Street Bakersfield, CA 93301 Our records indicate that your annual maintenance certification on your leak detection VOICE (661) 326-3941 FAX (661) 395-1349 system is past due on September 27, 2002. PREVENTION SERVICES YOU are currently in violation of Section 2641(J) of the California Code of FIRE SAFETY SERV1CES · EI~tIRONMEHTAL SERVICES 1715 Chester Ave. Reeulations. Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 326-0576 "Equipment and devices used to monitor underground storage tanks shall be installed, calibrated, operated and maintained in accordance with manufacturer's instructions, PUBLIC EDUCATION 1715 ChesterAv~. including routine maintenance and service checks at least once per calendar year for Bakersfield, CA 93301 Operability and running condition." VOICE (661) 326-3696 FAX (661) 326-0576 You are hereby notified that you have thirty (30) days, October 13, 2002, to either FIRE INVESTIGATION perfOrm or submit your annual certification to this office. Failure to comply will result 1715 ChesterAve. in revocation of your permit to operate your underground storage system. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661)326-0576 Should you have any questions, please feel free to contact me at 661-326-3190. TRAINING DIVISION 5642 Victor Ave. Sincerely, Bakersfield, CA 93308 VOICE (661) 399-469'7 FAX (661) 399-5763 Ralph Huey Director of Prevention Services Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services cc: Walter H. Port Jr., Assistant City Attorney · _'1' Postage $ "* ° 3/* rtl Certified Fee 2. ].0 133 Postmark Return Receipt Fee ]. o 50 Here ru (Endomement Required) I-1 Restricted Delivery Fee .~; ~ .~ r--I (Endorsement Required) · r-t Total Postage & Fees $ 3.9/* r~, DAVID P~ ...................... ...................................... ~. ~,/f~,'Stato, ZIP+ 4 BAKERSFIELD CA 93380 · Complete items 1, 2, and 3. Also complete Delivery item 4 if Restricted Delivery is desired. · Print your name and address on the reverse -so that we can return the card to you. Signature · Attach thi~ card to the back of the mailpiece, [ A [-I~ent or on the~ront if space permits. X~t,-,,.,:~ [~ ~',,~' /~l~A~dressee "I D. Is delivery address different fro~h~it~ 1~ [] Y~s 1. Article Addressed to: If YES, enter delivery address below: [] No DAVID PALMER JACO OIL ";CO P O BOX 1'807 BAKERSFIELD CA 93380 3. Service Type I~ Certified Mail [] Express Mail ~ [] Registered [] Return Receipt for Merchandise [] Insured Mail [] C.O.D. 4. Restricted Delivery? (Extra Fee) [] Yes 7001 0360 0002 5244 6981 PS Form 3811, July 1999 Domestic Return Receipt 102595-00-M-0952 July 31, 2002 David Palmer Jaco Oil P. O. Box 82515 Bakersfield, CA 93380 FIRE CHIEF RON FRAZE CERTIFIED MAIL ADMINISTRATIVE SERVICES 2101 ~H' Street Re; Failure to Perform or Submit Bakersfield, CA 93301 VOICE (661) 326-3941 Three Year Cathodic Protection Certification FAX (661) 395-1349 NOTICE OF VIOLATION & SUPPRESSION SERVICES 21Ol ',' Sl,eel SCHEDULE FOR COMPLIANCE Bakersfield, CA 93301 VOICE (661) 326-3941 Dear Customer: FAX (661) 395-1349 PREVENTION SERVICES According to our records, your three year Cathodic Protection Certification is past due m~ s~msE~ncEs.avm.~nsxsE~cEs at Chris's Liquors, Howards, #14, Howards (3300 Planz Rd), Wholesale Fuels (2200 E. 1715 ChesterAve. Brundage Ln). You are in violation of section 2635 2(a) Failure to Perform/Submit Bakersfield, CA 93301 VOICE (661) 326-3979 Cathodic Protection Testing results. FAX (661) 326-0576 Section 2635 2(a) is as follows: PUBLIC EDOCATION 1715 Chester Ave. Bakersfield, CA 93301 "Field-installed cathodic protection systems shall be designed and certified as adequate VOICE (661) 326-3696 by a corrosion specialist. The cathodic protection systems shall be tested by a cathodic FAX (661) 326-0576 protection tester within six months of installation and at least every three years thereafter." FIRE INVESTIGATION 1715 Chester Ave. Bakersfield, CA 93301 The cathodic protection is part of your leak detection system and is a condition of your VOICE (661) 326-3951 Permit to Operate. Therefore, prior to August 30, 2002, you shall either perform or FAX (661) 326-0576 submit evidence of cathodic protection testing. Failure to comply will result in revocation of your Permit to Operate. TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 Should you have any questions, please feel free to contact me at 661-326-3190. VOICE (661) 399-4697 FAX (661) 399-5763 Sincerely, Ralph E. Huey Director of Prevention Services By: ,.,, Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services D August 30, 2002 Wholesale Fuels P.O.Box 82277 Bakersfield, CA 93380-2277 RE: Deadline for Dispenser Pan Requirement December 3 l, 2003 ~IRE C.~EF REMINDER NOTICE RON FRAZE ADMINISTRATIVE SERVICES Dear Underground Storage Tank Owner: 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 You will be receiving updates fi.om this offices with regard to Senate FAX (601) 395-1349 Bill 989 which went into effect January 1, 2002. SUPPRESSION SERVICES 2101 "H* Street This bill requires dispenser pans under fuel pump dispensers. On Bakersfield, CA 93301 vOiCE (661) 326-3941 December 31, 2003 which is the deadline for compliance, this office FAX (661) 395-1349 will be forced to revoke your Permit to Operate, for failure to comply PREVENTION SERVICES with the regulations. 1715 Chester Ave. Bakerslield, CA 93301 VOICE (661)326-3951 It is the hope of this office that we do not have to pursue such action, FAX (661) 326-0576 which is why this office plans to update you. I urge you to start ENVIRONMENTAL SERVICES planning to retro-fit your facilities. 1715 Chester Ave. Bakersfie~, CA 93301 VOICE (661)326-3979 If your facility has been upgraded already, please disregard this notice. FAX (661) 326-0576 Should you have any questions, please feel free to contact me at 661- TRAINING DIVISION 326-3190. 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 Sin~~ FAX (661) 399-5763 Steve Unde Fire Inspector/Enviromental Code Enforcement Officer Office of Environmental Services SBU/kr L D July 31, 2002 Wholesale Fuels P. O. Box 82277 Bakersfield CA 93380-2277 RE: Deadline for Dispenser Pan Requirement December 31, 2003 FIRE CHIEF RON FR~-E ADMINISTRATIVE SERVICES 2101-.-Slreet REMINDER NOTI CE Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 SUPPRESSION SERVICES Dear Underground Storage Tank Owner: 2101 "H' Street Bakersfield, CA 93301 VOICE (661) 326-3941 You will be receiving updates from this office with regard to Senate FAX (661)395-1349 Bill 989 which went into effect January 1, 2002. PREVENTION SERVICES FIRE SAFE'T~ SER~ICES · ENYII~O#MENT/d. SER~CES 1715 ChestorAve. This bill requires dispenser pans under fuel pump dispensers. On Bakersfield, CA 9'3.301 December 31, 2003, which is the deadline for compliance, this office VOICE (661) 326-3979 FAX (661) 326-0576 will be forced to revoke your Permit to Operate, for failure to comply with the regulations. PUBLIC EDUCATION 1715 Chester Ave. Bakersfield, CA 93301 It is the hope of this office that we do not have to purse such action, VOICE (661) 320-3696 FAX (661)326-0576 which is why this office plans to update you. I urge you to start planning to retro-fit your facilities. FIRE INVESTIGATION 1715 Chester Ave. Bakersfield, CA 9.3.301 If your facility has been upgraded already, please disregard this notice. VOICE (661) 326-3951 FAX (661)326-0576 Should you have any questions, please fcc] free to contact me at 661- 326-3190. TRAINING DIVISION 5642 Victor Ave. VOICE (661) 399-4697 FAX (661) 399-5763 Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/dc D July 31, 2002 David Palmer Jaco Oil Co. P.O. Box 1807 CERTllqED MAIL FIRE CHIEF ~ON ~R~ZE Bakersfield. CA 93380 ADMINISTRATIVE SERVICES RE: Annual Maintenance on Leak Monitoring Systems 2101 "H" Street Bakersfield, CA 9,3301 VOICE (661)3~1 R E M I N D E R FAX (661) 395-1349 SUPPRESSION SERVICES Dear Mr. Palmer: 2101 'H' Street Bakersfield. CA 93301 This letter is to advise you that the following Jaco Oil sites are coming duc for annual VOICE (661) 326-3941 FAX (661) 395-1349 maintenance on their leak monitoring systems. They are as follows: PREVENTION SERVICES Howards Mini Mart 3300 Planz Road Due 08-17-02 s~Eves~,,v~,,.~n,~,r~,~m,~, Mt. Vernon Fastrip 3501 Mt. Vernon Duc 09-04-02 1715 Chester Ave. Bakersfield, CA 93301 Fastrip #622 4013 S. "H" St Duc 09-06-02 VOICE (661) 326-3979 Fastrip #641 1200 Coffee Rd Due 09-07-02 FAX (661) 326-0576 Chris' Liquors 2732 Brundage Ln '~ Due 09-07-02 Fastrip #6 1640 S. Chester - Duc 09-07-02 i~ua, uc EOUCA'rloN Ming & Real Fastrip 3701 Ming Ave Due 09-07-02 1715 Chester AVe. Bakersfield, CA 93301 Fastrip #19 4901 S. Union Due -0-07-02 VOICE (661) 326-3696 Fastrip #640 8001 White Lane Due 09-19-02 FAX (~1) 326-o576 Wholesale Fuels 2200 E. Brundage Due 09-27-02 FIRE INVESTIGATION Fastrip 0621 805 34t~ Street Due IO-01-02 1715 Chester^Ye. Fastrip #26 2698 Osweil Due 10-01-02 Bakersfield, CA 93301 Harris Market 1701 Union Ave Due 10-01-02 VOICE (661) 326-3951 Howards #6 4201 Belle Terrace Due 10-15-02 FAX (661) 326-0576 Farrelis Fastrip 6401 White Ln #112 Duc 10-15-02 Howard's #4 3200 Panama Ln Due 10-15-02 TRAINING DIVISION 5642 VlctorAve. Fastrip #633 6401 S. H Street Due 11-01-02 Bakersfield, CA 93.308 VOICE (661) 399-4697 As a courtesy, this reminder has been sent to you. No further reminders will be sent, and FAX (661) 399-5763 formal "Notices of Violation" will be sent 10 days after the due date, unless documentation of testing has been received. Should you have any questions, please feel free to call me at 661-326-3190. Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SB U/dc R D R r ,July 3[, 2002 David Palmer Jaco Oil P. O. Box 82515 F:~RE CHIEF Bakersfield, CA 93380 ~ON ~a,~Z~ CERTIFIED MAIL ADMINISTRATIVE SERVICES 2101 'H' Street Re: Failure to Perform or Submit Bakersfield. CA 93301 VOICE (661) 326-3941 Three Year Cathodic Protection Certification FAX (661) 395-1349 NOTICE OF VIOLATION & SUPPRESSION SERVICES ~,o1 '.' st.n~ SCHEDULE FOR COMPLIANCE Bakersfield, CA 93301 VOICE (661)326-3941 Dear Customer: FAX (r~l) 3o5.1349 PREVENTION SERVICES According to our records, your three year Cathodic Protection' Certification is past duc u/m s~.~cEs.armo.mEa .macs at Chris's Liquors, Howards, #14, Howards (3300 Planz Rd)~Wholesale Fuels (2200 E. 17~5 chester Ave, Bmnda_~.g.e_La). You are in violation of section 2635 2(a) Failure to Perform/Submit Bakersfield, CA 93301 vO[CE (6al) 326-397e Cathodic Protection Testing results. FAX (661) 3260576 Section 2635 2(a) is as follows: PUBMC EDUCATION 1715 Chester Ave. Bakersfield. CA 93301 "Field-installed cathodic protection systems shall be designed and certified as adequate VOICE (661) 326-3696 by a corrosion specialist. Thc cathodic protection systems shall be tested by a cathodic FAX (~1) ~s-o576 protection tester within six months of installation and at least cvclT thrc~ years thereafter." FIRE INVESTIGATION 1715 Chester Ave. Bakersfield, CA 93301 Thc cathodic protection is part of your leak detection system and is a condition of your VOICE (~I) 326-~sl Permit to Operate. Therefore, prior to August 30, 2002, you shall either perform or FAX (~I) 32~0S70 submit evidence of cathodic protection testing. Failure to comply will result in revocation of your Permit to Operate. TRAINING DIV1SION 5842 Victor Ave. Bakersfield. CA 93308 Should you have any questions, please feel free to contact mc at 661-326-3190. vOiCE (r~l) 39s.4~7 FAX (~1) 399-5783 Sincerely, Ralph E. Huey Director of Prevention Services By: Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services D July 1, 2002 Wholesale Fuels P.O. Box 82277 Bakersfield, CA, 93380-2277 RE: Deadline for Dispenser Pan Requirement December 3 I, 2003 for Site Location at 2200 E. Bmndage Lane, Bakersfield. C.iEF REMINDER NOTICE RON FRAZE ADMINISTRATIVE SERVICES Dear Underground Storage Tank Owner, 2101 "H" Street Bakersfield, CA 93301 VOICE (601) 326-3941 FAX (601) 395-1349 You will be receiving updates from this office with regard to Senate Bill 989 which went into effect January 1, 2000. SUPPRESSION SERVICES 2101 'H' Street Bakersfield. CA 93301 This bill requires dispenser pans under fuel pump dispensers. On December VOICE (661) 326-3941 FAX (661)395-1349 3 1, 2003, which is the deadline for compliance, this office will be forced to revoke your Permit to Operate, for failure to comply with the regulations. PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 It is the hope of this office, that we do not have to pursue such action, which VOICE (661) 326-3951 FAX(661)326-0570 is why this office plans to update you. I urge you to start planning to retro-fit your facilities. ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 If your facility has been upgraded already, please disregard this notice. VOICE (601) 326-3979 FAX (661) 326-0576 Should you have any questions, please feel free to contact me at (661)326- 3190. TRAINING DIVISION 5642 Victor Ave. n~~ ~ Bakersfield, CA 93308 Si VOICE (661) 399-4697 FAX (661) 399-5763 * Ste'0e Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services D _ August 30, 2002 Wholesale Fuels P.O.Box 82277 Bakersfield, CA 93380-2277 RE: Deadline for Dispenser Pan Requirement December 31, 2003 --,R~ C,~EF REMINDER NOTICE ADMINISTRATIVE SERVICES Dear Underground Storage Tank Owner: 2101 'lq' Street Bakersfield. CA 93301 VOICE t~t) atS-3~ YOU will be receiving updates from this offices with regard to Senate Fax (66, 396-t ~9 Bill 989 which went into effect January 1, 2002. SUPPRESSION SERVICES ~to~ -lq' street This bill requires dispenser pans under fuel pump dispensers. On Bakersfield. CA 93301 ¥o~ce 166t) ~26.~94t December 3 I, 2003 which is the deadline for compliance, this office will be forced to revoke your Permit.to Operate, for failure to comply PREV£N'nON SERWCES with the regulations. t 71S Chester Ave. Bakerstiotd. CA 93301 voice I~) 326-39~, It is the hope of this office that we do not have to pursue such action, FAX (661) 32ti-0576 which is why this office plans to update you. I urge you to start ENWRONMENTAL SERVICES planning to retro-fit your facilities. ! 7 ! 5 Chester Ave. Bakersfield. CA 93301 voice (66~)~26-3~79 If your facility has been upgraded already, please disregard this notice. Should you have any questions, please feel free to contact me at 661- TRAININO mv~s~on 326-3190. 5642 Victor Ave. Bakersfield. CA 93308 voice t66~ ~99-a69z Sincerelx Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/kr R L D July 3 l, 2002 Wholesale Fuels P. O. Box 82277 Bakersfield CA 93380-2277 RE: Deadline for Dispenser Pan Requirement December 31, 2003 FIRE CHIEF ~CN s,,.., REMINDER NOTICE Bakerslleld, CA 93301 VOICE (661) 326-3~41 FAX (681) 395-1349 SUPPRESSION SERVICES Dear Underground Storage Tank Owner: 2101 'H' Streel Bakersfield, CA 93301 VOICE (661)326-3941 YOU will be receiving updates from this office with regard to Senate FAX (661) 395-1349 Bill 989 which went into effect January 1, 2002. PREVENTION SERVICES 1715 ChesterA~. This bill requires dispenser pans under fuel pump dispensers. On ~.,k,rsf,,ld. CA ~e.30~ December 3 1, 2003, which is the deadline for compliance, this office VOICE (681) 320-3979 FAX (681) 328-.0576 will be forced to revoke your Permit to Operate, for failure to comply with the regulations. PUBLIC EDUCATION 1715 Chesler Ave. Bakersfield. CA 93301 It is the hope of this office that we do not have to purse such action, VOICE (661) 326-3696 FAX (681)326-0576 which is why this office plans to update you. I urge you to start planning to retro-fit your facilities. FIRE INVESTIGATION 1715 Chester Ave. &'~emfleld. CA {~30! If your facility has been upgraded already, please disregard this notice. vo,cE (68~) FAX (661)326-0576 Should you have any questions, please feel free to contact me at 661- 326-3190. TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 S incerely.~ VOICE (661) 3994697 FAX (661) 399-5763 Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/dc ~,~, ~.g:?~ S:~,ORR~IS~ONDENCEX2I~2.0~DLIN~R DISPFi~J~ PAN L~ .. · · D May 30, 2002 Wholesale Fuels P.O. Box 82277 Bakersfield, CA 93380-2277 RE: Deadline for Dispenser Pan Requirement December 31, 2003 on Underground Storage Tank(s) located at 2200 E. Brundage Lane, Bakersfield. FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES Dear Underground Storage Tank Owner: 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 You will be receiving updates from this office with regard to Senate Bill 989 FAX (661) 395-1349 which went into effect January 1, 2000. SUPPRESSION SERVICES 2101 'H" Street Bakersfield, CA 93301 This bill requires dispenser pans under fuel pump dispensers. On December vOICE (661) 326-3941 3 1, 2003, which is the deadline for compliance, this office will be forced to FAX (661) 395-1349 revoke your Permit to Operate, for failure to comply with the regulations. PREVENTION SERVICES 1715 Chester Ave. Bakersfield. CA 93301 It is the hope of this office, that we do not have to pursue such action, which VOICE (661) 326-3951 FAX(661) 326-0576 is why this office plans to update you. I urge you to start planning to retro-fit your facilities. ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield. CA 93301 If your facility has been upgraded already, please disregard this notice. VOICE (661) 326-3979 FAX (661)326-0576 Should you have any questions, please feel free to contact me at (661)326- 3190. TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 Sincere 2, ~ FAX (661) 399-5763 St rwo Fire Inspector/Environmentai Code Enforcement Officer Office of Environmental Services SBU/kr D February 11, 2002 John Kerley JACO Oil FIRE CHIEF P O Box 1807 RON [R~ZE .... Bakersfield cA '933-03 ADM'NISTRaTIVE SERVICES 2101 "H" Street RE: Deadline for Dispenser Pan Requirement December 31, 2003 Bakersfield, CA 93301 VOICE (661) 326-3941 for the Following Locations: Chris' Liquor, 2732 Brtmdage Lane, FAX (661)395-1349 Fastrip, 8001 White Lane, Fastrip 1200 Coffee, Fastrip, 4901 S. Union sUPPRESSION SERVICES Ave., Fastrip, 805 34th St., Fastrip, 4013 S. "H" St., Wholesale Fuels, 2101 "H" Street 2200 E Brundage Ln., Howard's Mini Mkt., 3200 Panama Ln., Howard's Bakersfield, CA 93301 Mini Mkt., 4201 Belle Terrace, Howard's Mini Mkt., 3300 Planz Rd., :VOICE (661) 326-3941 FAX (661) 395-1349 Ming & Real Fastrip, 3701 Ming Ave., Mt. Vemon Fastrip, 3501 Mt. Vernon Ave., Harris Mkt., 1701 Union Ave. PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA93301 RE MINI) E R N.OT I C E 'VOICE (661) 326-3951 FAX (661) 326-0576 Dear Underground Storage Tank Owner: ENVIRONMENTAL SERVICES ....... .... 1715 ChesterAve. You will be receiving updates fr~m this office with regard to Senate Bill 989 Bakersfield, CA 93301 VOICE (661) 326-3979 which went into effect January 1, 2000. FAX (661) 326-0576 This bill requires dispenser pans under fuel pump dispensers. On December 31, TRAINING DIVISION 5642 Victor Ave. 2003, which is the deadline for compliance, this office will be forced to revoke ,Bakersfield, CA 93308 your Permit to Operate, for failure to comply with.the regulations. VOICE (661) 399-4697 · ' FAX (661) 399-5763 It is the hope of this office, that we do not have to pursue such action, which is why this office plans to update you. I urge you to start planning to retro-fit your facilities. If your facility has been upgraded already, please disregard this notice. Should you have any questions, please feel free to contact me at 661-326-3190. Sincerely, Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/dm FROM : SUNSET MECHANICAL PHONE NO. : 805 3220660 Jan. 02 2002 03:49PM P4 Construction & MECHANICAL (S61) 871-1788 Continuous Monitorinc Device Certification TEST DATE .,~ _.~.., ~/ FAC,L,~ NUMeE, /~,~ CONTACT PERSON -- FAC,UT, NA~E ~~~ ~~ ~ , ,, ~. MA~ ~D MOD~L OF MONITORING SYSTEM ~ ~O ~~~ Co,tents of Tank ............ ~'c~ Capacity o~..~ank ~ ~.~ . Type of Product Line (~?vit~, Suction, Pressure) ............. &> ~ INDICATE LOCATION OF THE MONITORING SENSORS TESTED BY PLACING A YEs OR No ~N THE APPLICABLE BOX; Annular Space Sensor Sump Sensor Dispenser Containment Sensor /,Z~ Ax',.> Electronic Overfill/Level Electronic In-Line Leak Detector Mechanical Line Leak Detector In-Tank Gauging Device JNDICATE THE FOLLOWING BY PLACING A YES OR No IN APPLICABLE BOX'. 'C;'oes !he M.onitoring System have audible and vi,s,,,u..~!,.a, la, r.rns? Does the turbine automatically shut down if the system detects ? I.eak, fails to operate or is electroni_c.~l!y d!sc..onne..~.ed? /4/,~5 Is the mo,~it,or!ng sy, st,em !n~talled to prevent unau[horized tampering? Is the monitoring system operable as per the manufacturer's specifications? Which continuous monitoring devices Initiate positive shut down of the turbine? SK~NATUR~ OF' CERTIFI~D TEChNiCIAN PRINTED NAME OF .CERT, F,ED TECHNIC,AN TESTING COMPANY NAME & TELEPHONE CERTiFICATiON DATA FROM : SUNSET MECHANICAL PHONE NO. : 805 3220660 Jan. 02 2002 03;48PM P3 Construction & MECHANICAL (661) 871-1788 Continuous Monitod~g Device Certification T~NK 1 T~K 2 TA~ ~ T~N~ 4 Type of Product Line (Gravity, Suction, Pre,~r~ 2 P ~ ~ ~ ~,, iNDICATE LOCATION OF THE MONITORING SENSORS TESTED BY PLACING A YES OR NO IN THE APPLICABLE BOX: -Annular Space Sensor /¢~ /,,~o ~'*.-~, Sump Sensor Dispenser Containment Sensor Mechanical Line Leak Detector ~,/~ iNDICATE THE FOLLOWING BY PLACING A YES OR No IN APPLICABLE BOX' Does the Monitoring System have audible and visual alarms? Does the turbine automatically shut down if the system detects a leak, fail~ ~o operate or is electronically di~connecled? IS the monitoring system installed to prevent unauthorized tampering? Is ~ ~nitoring system operable ........ as per the manufacturer's specifications?l Which continuous monitoring devices Initiate positive.shut down of the turbine?~¢ CERTIFICATION DATA D · September 1 O, 2001 John Kerley Jaco Oil Company CERTIFIED MAIL PiO. Box 1807 Bakersfield, Ca 93380 ~eE CH~E~ NOTICE OF EXPIRATION RON FRAZE ON MONITORING CERTIFICATION ADMINISTRATIVE SERVICES 2101 "H' Street Dear Mr. Kerley: Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 The following Jaco sites are currently due/past due on annual monitoring certification. These sites are as follows: SUPPRESSION SERVICES 2101 "H" Street Site Address .Due Date Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 1. Fan'ells Fastrip, 6401 'White Lane 9-04-01 2. Chris Liquors, 2732 Brundage Lane 9-05-01 PREVENTION SERVICES 3. Fastrip #640, 8001 White Lane 9-05-01 1715 Chester Ave. Bakersfield. CA 93301 4. Wholesale Fuels, 2200, Brundage 9-12-01 VOICE (661) 326-3951 5. Fastrip #19, 4901 S. Union 9-12-01 FAX (661) 32e-0576 6. Fastrip #621,805 34'h 9-20-01 7. Fastrip #6, 1640 S. Chester 9-22-01 ENVIRONMENTAL SERVICES 1715 Chester Ave. 8; Fastrip, #26, 2698 Oswell Street 9-22-01 Bakersfield, CA 93301 9. Howards g4, 3200 Panama Lane 9-23-01 VOICE (661) 326-3979 FAX (661) 326-0576 10. Fastrip #622, 4013 "H" Street 9-27-01 11. Ming & Real Fastrip, 3701 Ming Ave 9-27-0 l TRAIN~Na DIVISION 12. Fastrip #641, 1200 Coffee Road 9-28-01 5e42 Victor Ava. · 13. Howard's #6, 4201 Belle Terrace 9-28-01 Bakersfield, CA 93308 VOICE (661) 399-4697 14. Howard's, 3300 Planz Road 9-28-01 vAX (659 399-57~3 15. Harris Market, 1701 Union Ave 9-30-01 16. Mt. Vernon Fastrip, 3501 Mt. Vernon 10-2-01 Failure to perform or submit monitoring certification within 30 days of due date will result in revocation of your Permit to Operate. Should you have any questions, please feel free to contact me at 661-326-3190. Steve Underwood Fire Inspector/Environmental Code Enforcement Office Office of Environmental Services SBU/dm D August 3, 2001 Wholesale Fuels FIRE CHmF P O Box 82277 RON m~E Bakersfield Ca 93380-2277 ADMINISTRATIVE SERVICES 21Ol "H" Street RE: Deadline for Dispenser Pan Requirement December 31, 2003 Bakersfield, CA 93301 voice (661,1 FAX 1661)39s-1~9 R E M I N D E R N O T I C E SUPPRESSION SERVICES 2101 'H" Street Dear Tank Owner: Bakersfield, CA 93301 unaergrouno ~[orage VOICE (661) 326-:3941 You will be receiving updates fi.om this office with regard to Senate Bill PREVENTION SERVICES 989 which went into effect January 1, 2000. 1715 Chester Ave. Bakersfield, CA 93301 vOiCE (661) 326-39Sl This bill requires dispenser pans under fuel pump dispensers. On FAX (661) 326-0.~76 December 31, 2003, which is the deadline for compliance, this office will ENVIRONMENTAL SERVICES be forced to revoke your Permit to Operate, for failure to comply with the 1715 Chester Ave. Bakersfield, CA 93301 regulations. VOICE (661) 326-3979 FAX (661) 326-0576 It is the hope of this office, that we do not have to pursue such action, TR^ININa reVISiON which is why this office plans to update you. I urge you to start planning 5642 Victor Ave. Bakersfield, CA 93308 toretro-fityour facilities. VOICE (661) 399-4697 FAX (661)399-5763 If your facility has been upgraded already, please disregard this notice. Should you have any questions, please feel free to contact me at 661-326- 3190. Steve Unde~ood Fire Inspector/Enviromental Code Enforcement Officer Office of Enviromental Se~ices SBU/dm D February 6, 2001 Wholesale Fuels FIRE CHIEF John Browning RON FRAZE P O Box 822?? ADMINISTRATIVE SERVICES Bakersfield Ca 93380 2277 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 RE: Rolling Power Outages FAX (661) 395-1349 SUPPRESSION SERVICES Dear Mr. Browning: 2101 "H" Street Bakersfield, CA 93301 VOICE (661)326-3941 With the threat in California of continued rolling power outages now, and FAX (661)395-1349 in the immediate future, this office requests your assistance. PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 This office is requesting that if, "during a fuel drop," the power goes out VOICE (661) 326-3951 due to rolling power outages, that you immediately stop dropping fuel FAX (661) 326-0576 until power is restored. ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 As you are aware automated monitoring systems will be off line during a VOICE (661) 326-3979 power outage, which could compromise safeguards. FAX (661) 326-0576 TRAINING DIVISION TO ensure the safety of both human hca]th, and thc environment, we 5642 Victor Ave, Bakersfield, CA 93308 request that you make this part of your policy. VOICE (661) 399-4697 FAX (661) 399-5763 Should you have any questions, please fccl fmc to call mc at 661-326- 3190. SinceT~ - Steve Underwood, Inspector Office of Environmental Services SBU/dm D January 24, 2001 Wholesale Fuels FIRE CHIEF John Browning RON FRAZE P O Box 70097 ADMINISTRATIVE SERVICES ~_B_akersfi eld_Ca ~ 03387 2101 "H" Street Bakersfield, CA 93301 . VOICE (661) 326-3941 RE: Rolling Power Outages FAX (661) 395-1349 SUPPRESSION SERVICES Dear Mr. Browning: 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 With the threat in California of continued rolling power outages now, and FAX (661) 395-1349 in the immediate future, this office requests your assistance. PREVENTION SERVICES 1715 ChesterAve. ;fhi:s' office is requesting that if, "during a fuel drop," the power goes out Bakersfield, CA 93301 VOICE (661)326-3951 due to rolling power outages, that you immediately stop dropping fuel FAX (661) 326-0576 - until power is restored. ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 AS you are aware auto'mated monitoring systems will be off line during a VOICE (661)326-3979 power outage, which could compromise safeguards. FAX (661) 326-0576 TRAINING DIVISION To ensure thc sa£cty of both human health, and thc environment, wc 5642 Victor Ave. Bakersfield, CA 93308 request that you make this part of your policy. VOICE (661)399-4697 FAX (661)399-5763 - Shou!d ye, h.ave a_nyques?ions, p!,ea, se. feel free to call me at 661-326- 3190. Sincerely, Steve ~Underwood, Inspector Office~f_E,.nvironmental Services ',:' :,, :~'.,i~.,;~. ::,c.,' ' :' -~ ,: :... .... '.-. ". ...... .: :., -.~,..~- sBU/dm:'"' '~: ~'':'J'" '"' D January 22, 2001 FIRE CHIEF RON FP.~_E Wholesale Fuels 2200 E Bmndage Lane ADMINISTRATIVE SERVICES Bakersfield Ca 93307 2101 "H" Street Bakersfield. CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 RE: Dispenser Pan Requirement December 31, 2003 Underground Storage Tank Dispenser Pan Update SUPPRESSION SERVICES .. 2101 "H" Street Bakersfield, CA 93301 Dear Underground Storage Tank Owner: VOICE (661) 326-3941 FAX (661)395-1349 You will be receiving updates from this office now, and in the furore with PREVENTION SERVICES regard to the Senate Bill 989, which went into effect January 1, 2000. 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 326-0576 This bill requires dispenser pans under fuel pump dispensers. On December 31, 2003, which is the deadline for compliance, this office will ENVIRONMENTAL SERVICES be forced to revoke your permit to operate, effectively shutting down your 1715 Chester Ave. Bakersfield, CA 93301 fueling operation. VOICE (661) 326-3979 FAX (661) 326-0576 It is thc hope of this office, that we do not have to pursue such action, TRAINING DIVISION which is why this office plans to update you. I urge you to start planning 5642 Victor Ave. Bakerstield, CA 93308 now to retro-fit your facilities. VOICE (661) 399-4697 FAX (661) 399-5763 If your facility has upgraded already, please disregard this notice. Should you have any questions, please feel free to contact me at 661-326-3190. Sincerely, Steve Underwood, Inspector Office of Environmental Services SBU/dm - May 3, 1999 Charles McCan, President Wholesale Fuels, Inc. ~,~ C.,EF 2200 E. Brundage Lane RoN FROZE Bakersfield, CA 93307 ADMINISTRATIVE SERVICES 21o4 'H' street CERTIFIED MAIL Bakersfield, CA 93301 vO,CE (805) 32~-3941 FAX (805)39~-~349 TEMPORARY EXEMPTION NOTICE SUPPRESSION SERVICES CALARP RISK MANAGEMENT PLAN 2101 'H' Street Bakersfield, CA 93301 VOICE (805) 326-3941 FAX (805) 395-1349 Dear Mr. McCan; PREVENTION SERVICES The attached notice from the United States Environmental 1715 Chester Ave. Bakersfield, CA 93301 Protection Agency temporarily exempts propane from the June 21, 1999 VOICE (805) 326-3951 FAX (805) 326-0578 Risk Management Plan submission date. Em.O.ME.Tn. SE.WC~S Our records indicate that your facility now qualifies under this 1715 Chester Ave. - Bakersfield. CA 93301 exem_ption. You will not be required to submit a Risk Management Plan VOICE (805) 326-3979 FAX (805) 326-0576 by June 21, -1~999, nor comply with the additional California Accidental Release Program (CalARP), as of that date. You will, however, still be TR~.lnO DIVISION required to comply with all existing local fire codes and ordinances for the 5642 Victor Ave. Sakersne~d, CA 93308 safe storage and handling of flammable gases, but will not be subject to VOICE (805) 399-4607 FAX (805) 399-5763 further regulation involving thc new CalARP Risk Management Plan until further notice. If you have any questions regarding this exemption, please call me at (661) 326-3979. Sincerely, Howard H. Wines, III Hazardous Materials Specialist Office of Environmental Services HHW/dm attachment - March 29, 1999 Charles McCan, President Wholesale Fuels, Inc. 2200 E. Brundage Lane Bakersfield, CA 93307 CERTIFIED MAIL FIRE CHIEF RON FRAZE 90 DAY NOTICE ~M,.,s~m~ SE.VICES CalARP RISK MANAGEMENT PLAN & 2101 'H' Street Bakersfield, CA 93301 vo,cE (805)326-3941 PREVENTION PROGRAM REQUIRED FOR FAX (~05)395`1~9 SUBMISSION & IMPLEMENTATION PRIOR TO su...~ss,o, s~.vic~s JUNE 21, 1999 2101 'H" Street Bakersfield, CA 93301 VOICE (805) 326-3941 FAX (805) 395-1349 Dear Mr. McCan: PREVENTION SERVICES The intent of this letter is to inform you of the necessary deadlines 1715 Chester Ave. Bakersfield. CA 93301 for complying with the California Accidental Release Program (CalARP) VOICE (805) 326-3951 FAX (805)326-o578 including submission of the required Risk Management Plan and implementation of the appropriate Prevention Program prior to June 21, ENVIRONMENTAL SERVICES 1999. 1715 Chester Ave. Bakersfield, CA 93301 VOICE (805) 326-3979 FAX (005) 326,0576 Our records indicate that your facility was previously notified of these requirements by Certified Mail dated June 17, 1998. At this time, TRAINING DIVISION you should have already coordinated with this office on the method of 5642 Victor Ave. Bakersfield, CA 93308 Hazard Review or Process Hazard Analysis to be conducted, the VOICE (805) 399-4697 FAX (805) 399-5763 appropriate Prevention Program level to be implemented and the Management System employed at your facility to oversee all such CalARP requirements. If you have not yet done so, or have any questions regarding the necessary level of coordination between your facility and our office concerning CalARP, please call me immediately at 661-326-3979. Sincerely, Howard H. Wines, III Hazardous Materials Specialist Office of Environmental Services HHW/dm ,O April 20, 1999 Charles McCan President Wholesale Fuels Inc 2200 E Brundage Lane Bakersfield CA 93307 RRE CHI£F CERTIFIED MAIL RON FR~E ADMINISTRATIVE SERVICES 2101 'H' Street Bakersfield, CA 93301 60 DAY NOTICE vo,cE (805)326-3~1 r~x (805)39s-1~9 CALARP RISK MANAGEMENT PLAN & PREVENTION PROGRAM REQUIRED FOR suP.uess,o. SEaVICES 2101 'H' Street SUBMISSION & IMPLEMENTATION PRIOR TO Bakersfield, CA 93301 vo.cE (805)326-3~1 ~Ax (805)395-1~9 JUNE 21, 1999 PREVENTION SERVICES Dear Mr. McCan: 1715 Chester Ave. Bakersfield, CA 93301 VOICE (S0S) 326-3951 FAX (805)326-0576 The intent of this letter is to inform you of the rapidly approaching deadline for complying with the California Accidental Release Program ENVIRONMENTAL SERVICES (CalARP) including submission of the required Risk Management Plan 1715 Chester Ave. Bakemfield, CA 93301 and implementation of the appropriate Prevention Program prior to VOICE (805) 326-3979 FAX (805) 326-0576 June 21, 1999. TRAINING DIVISION Our records indicate that your facility is subject the CalARP 5642 Victor Ave. Bakersfield, CA 93308 requirements. By this time, you should have already completed the VOICE (805) 399-4697 FAX (805) 399-5763 Hazard Review or Process Hazard Analysis, the Off-Site Consequence Analysis, and have entered the necessary data into your Risk Management Plan (RMP) for submission to this office and possibly the United States Environmental Protection Agency (if also subject to federal regulations). If you have not yet done so, or have any questions regarding the necessary level of coordination between your facility and our office concerning CalARP, please call me immediately at 661-326-3979. Sincerely, Howard H. Wines, III Hazardous Materials Specialist Office of Environmental Services D !' December 16, 1998 Charles McCan, President Wholesale Fuels, Inc. 2200' E. Brundage Lane Bakersfield, CA 93307 FIRE CHIEF ~o~ ~ZE RISK MANAGEMENT WORKSHOP FOR INDUSTRY ADMINISTRATTVE SERVICES 2101 'H' Street ~kers~e~d. C~ 93301 JANUARY 7, 1999, 9:00 A.M. VOICE (805) 326-3941 FAX (805)395-1349 OLIVE DRIVE FIRE TRAINING FACILITY SUPPRESSION SERVICES Dear Mr. McCan: 2101 'H' Street Bakersfield, CA 93301 VOICE (805) 326-3941 A workshop conducted by the Governor's Office of Emergency Services FAX (805) 395-1349 regarding the new California Accidental Release Prevention (CalARP) and PREVENTION SERVICES associated Risk Management Plan programs will be held in Bakersfield on 1715 Chester Ave. Thursday, January 7, 1999 at 9:00 a.m. at the Olive Drive Fire Training Facility Bakersfield, CA 93301 VOICE (805) 326-3951 located at 5642 Victor Street. FAX (805) 326-0576 You have been previously notified by this office that your facility is ENVIRONMENTAL SERVICES likely to be subject to the new CalARP requirements, including the 1715 Chester Ave. Bakersfield, CA 93301 implementation of a specified Prevention Program and submission of a Risk VOICE (805) 326-3979 FAX (805) 326-0576 Management Plan on or before June 21, 1999. This workshop should help answer any questions you may have. TRAINING DIVISION 5642 Victor Ave. A letter of invitation, agenda, Request for Comments Letter, and the text Bakersfield, CA 93308 VO/CE (805)399-4697 of the CalARP regulations are enclosed. You may wish to familiarize yourself FAX (805) 399-5763 with the regulations and bring them along to the workshop for your reference. A map of the workshop location and surrounding restaurants is also attached. Please make every effort to attend this important event. Sincerely, Howard H. Wines, III Hazardous Materials Specialist Office of Environmental Services HHW/dm attachment enclosures I'~ ~ Bakersfield Fire Dept PERMI! NO. OFFICE OF ENVIRONMENTAL SERVICES UNDERGROUND STORAGE TANK PROGRAM PERMIT APPLICATION TO CONSTRUCT/M_ODIFY UNDERGROUND STORAGE TANK I~.PE OF APPI. ICATIOH (CHECIC) Ci NEW FACILITY Ct MODIFIC'ATION OF FACILITY CI NEW TANK INSTALLATION AT EXISTING FACILITY STARTING DATE / PROPOSED COMPLETION DATE FACILITY NAMEu_~/,. ~,/.,../=~/'//(.o///-~~ ~ EXISTING FACILITY PERMIT No. ~ FACILITY ADDRE$~ ZP-.~OC) ~c-.//~'~x~,,./~,~._., ~~/'E"l~ ~/4t ZIP CODE TYPE OF BUSINESS Fq~i~ ~~ u , APN TANK OWNER ~ C3\L. c~_o~-~ ~ PHONE No~E~) -- ADDRESS ~!o ! _~'7'0_7' & F~., CiTY ~ ZiP ~OD'E CONTRACTOR /~,o$~ ~,~---~/' o.'N'*"~ CA LICENSE No..'"-,//~F,Z.-~ ADDRESS~ /i ~' ~ T~ ClW '-4~,~[C. df~f'/~.---h) ZIP CODE PHONE No. [~57 ~.~o ~ C o ~ BAKERSFIELD CITY BUSINESS LICENSE No. WORKMAN COMP. No. INSURER / WATER TO FACILITY PROVIDED BY DEPTH TO GROUND WATER SOIL TYPE EXPECTED;~'T:SITE No. OF TANKS TO BE INSTALLED ARE THEY FOR MOTOR FUEL - Ct YES El NO TANK No. VOLUME UNLEADED REGULAR PREMIUM DIESEL AVIATION K ' .Z,' · No. VOLUME CHEMICAL STOJ~ED CAS No. CHEMICAL PREVIOUSLY (no brand name) (if known) STORED THE APPLICA N[ HAS ~ECEIVEO. UNOEESTANOS, ANO WILL COMPLY WffH THE A~ACHEO CONDITIONS OF THIS PERMIT AND ANY OTHER ~ UNOER PENALW OF PERJURY. AND TO THE ~EST OF MY KNOWLEDGe, iS TRUE AND CORRECT. ~~ APPLICANT NAME (PRIND APPLICANT SlGNAfURE THIS APPLICATION BECOMES A PERMIT WHEN APPROVED BAKERSFIELD FIRE DEPARTMENT June 30, 1998 Charles McCan Wholesale Fuels Inc FIRE CHIEF mCHAEL R. m'Y P.O. Box 70097 Bakersfield, CA 93387-0097 ADMINISTRATIVE SERVICES 2101 "H' Street Bakersfield, CA 93301 (805) 326-3941 F~(~) ~,~,S-l~,~ UNDERGROUND STORAGE TANK UPDATE SUPPRESSION SERVICES 2101 'H' Street Bakersfield, CA 93301 Dear Underground Storage Tank Owner: (805) 326-3941 FAX (805) 395-1349 The City of Bakersfield and Kern County Environmental Health will hold PREVENTION SERVICES a Underground Storage Tank Workshop. 1715 Chester Ave. Bakemfleld, CA 93301 C805) 326-3951 This will be the final opportunity, befOre the December 22, 1998 deadline, FAX (805) 326-0576 to ask questions regarding upgrade, removals, financing, and other related ENVIRONMENTAL SERVICES requirements. 1715 Chester Ave. Bakersfield, CA 93301 (805)326-3979 ThC workshop will be held on Friday, July 17, 1998, from 8:00 a.m. - FAX (805)326-0576 12:00 Noon. The location will be the Kern County Environmental Health Services Department, 2700 "M" Street, First Floor Conference Room. TRAINING DIVISION 5642 Victor Street Bakersfield, CA93308 Enclosed is a registration form. Please fill out and mail or fax before the (805) 399-4697 FAX(805) 399-5763 registration deadline, July 17, 1998. I look forward to seeing you there. Sincerely, Steve Underwood Underground Storage Tank Inspector Office of Environmental Services SBU/dm enclosure cc: Ralph Huey, Director,. Office of Environmental Services B A K E R S F I E L 'D FIRE DEPARTMENT June 17,1998 Charles McCan, President I:ll~ CHIEF Wholesale Fuels, Inc. MICHAEL R. KELLY 2200 E. Brundage Lane Bakersfield, Ca 93307 ADMINISTEATIVE SEI~VICES 2101 'H" Street Bake~'fleld, CA 93301 CERTIFIED MAIL (805) 326-394 I FAX (805)395-1349 NOTICE OF RISK MANAGEMENT PLAN (RMP) REQUIRED BY JUNE 21, 1999 SUPPRESSION SEEVICES 2101 'H" Street Bakersfield, CA 93,301 Dear Mr. McCan: (805) 326-3941 FAX (805) 395-1349 Your facility has been identified by [his office as a probable candidate to be subject to the new California Accidental Release Program (CalARP), which will involve among many other ~[:VmnOn S~aCES requirements, the submission ora Risk Management Plan to this office, and also to the United 1715 Chestor Avo. Bakersfield, CA 93,301 States Environmental Protection Agency (USEPA) in many cases, on or before June 21, 1999. (805) 326-3951 lAX (80,5)326-0576 The CalARP regulations are a merging of the federal and state risk management prevention programs for accidental release prevention of several hundred listed flammable or ENVIRONMENTAL SERVICES toxic substances (e.g.: ammonia, chlorine, propane, etc.) which pose the greatest risk of causing 1715 Chester Ave. death, injury, or seriously affecting human health or the environment if accidentally released. Bake~field, CA 93301 (805) 326-3979 FAX (805)326-0576 The rule requires certain facilities to develop and implement an integrated system to identify hazards and manage risks associated with these regulated substances. Since your facility n~Jt~tnG D~SlON appears to be subject to this rule, you will be required to analyze worst-case releases, document a 5642 Victor Street five-year history of serious accidents, coordinate with local emergency responders, develop and Bakersfield, CA 93308 (805) 3994697 implement a prevention program that includes, among other steps, identification of hazards, FAX (805)399-5763 written operating procedures, training, maintenance, and accident investigation. If your employees also respond to accidental releases, you must implement an integrated local emergency response program. An informative digest is enclosed for your reference. The text of the regulations, technical assistance, and other information is available from our office by calling me directly at (805) 326-3979. Sincerely, Howard H. Wines, III Hazardous Materials Specialist Office of Environmental Services HHW/dm enclosure BAKERSFIELD FIRE DEPARTMENT May 31, 1998 Charles McCan Wholesale Fuels lnc FIRE CHIEF MICHAELR. KELLY P.O. Box 70097 Bakersfield, CA 93387-0097 ADMINi$1RATIVE SERVICES 2101 'H' Street Bako~eld, CAg&301 RE: 2200 E. Brundage Lane (805) 326-3941 FAX (805) 395-1349 suPm~s,o, ~c~ UNDERGROUND STORAGE TANK UPDATE 2101 'H' Street Bakersfield, CA 93301 (805) 326-3941 FAX (805) 395-1349 I~EVENIION SERVICES Dear Underground Storage Tank Owner: 1715 Chester Ave. Bakersfield, CA 93,301 (80,5) 326-3951 The City of Bakersfield wishes to congratulate those tank owners who FAX (805) 326-0576 have upgraded, removed or replaced their tanks in the first quarter of 1998. This ENVIEONMENTAL SERVICES office is expecting an even bigger second quarter result. This commitment, has 1715 Chester Ave. helped this office achieve a 75% compliance average for the underground storage Bakersfield, CA 93301 (00,5) 326-3979 tanks within the City. This is a very "good start". FAX (805) 326-0~76 For the benefit of those who have not yet upgraded, the City of 11bRINING DIVISION 5642 Victor Street Bakersfield and Kern County Environmental Health, will conduct a Underground Bakers~eld, CA93308 Storage Tank Workshop scheduled for Friday, July 17, 1998, from 8:00 a.m. - 12 (805) 399-4697 FAX (805)399-5763 noon. Look for our June letter for more details. Should you have any questions, please feel free to contact me at 326-3979. Sincerely, Steve UnderWood Underground Storage Tank Inspector' SBU/dm cc: Ralph Huey, Director BAKERSFIELD FIRE DEPARTMENT February 24, 1998 Mr. Charles McCan Wholesale Fuels, Inc. P.O. Box 70097 FIRECHIEf Bakersfield, CA 93387-0097 MICHAEL R. KELLY RE: 2200 E. Brundage Lane ADMINISTRATIVE SERVICES 2101 'H' Street Bako ,e,d,C^ 0 UNDERGROUND STORAGE TANK UPDATE (80,5) 326-3941 FAX (805) 395-1349 Dear Underground Storage Tank Owner: SUPPRESSION SElf/ICES 2101 'lq" Street The City of Bakersfield has some exciting news regarding loan monies, which has just Bakersfield, CA 93301 (~5) 326-3941 become available through the Small Business Loan Association (SBA). FAX (80S) 396-1349 Pollution Control loans, thru the SBA, are intended to provide loan quarantees to eligible I~EV[NIION SERVICE$ 1715 Chester Ave. small businesses for the financing of planning, design, or installation of pollution prevention Bakersfield, CA93301 controls, which includes underground storage tank facilities. (805) 326-3951 FAX (806) 326-0576 The vast majority of businesses are eligible for financial assistance from the SBA. The ENVIRONMENTAL SEI~ICES SBA defines an eligible small business as one that is independently owned and operated and not 1715 Chester Ave. dominant in its field of operation. For those applicants that meet the SBA's credit eligibility Bakersfield, CA 93301 (80,5) 326-3979 standards, the agency can quaranty up to eighty percent (80%) of loans of $100,000. Seventy five FAX C805)32643576 percent (75%) of loans above $100,000. Lynn Knutson, Chief of Finance for the SBA says, "If customers apply immediately, and meet the requirements, funding is available". TRAINING DIVISION 5642 Victor Street Bakersfield, CA 93308 The City of Bakersfield hopes all of our underground storage tank owners take advantage (805) 3994697 of this opportunity. For more information on SBA, Pollution Control Loans, please call or write to: FAX (805) 399-5763 Lynn Knutson, Chief Financial Officer Small Business Loan Association 2719 North Air Fresno Drive, Suite 200 Fresno, CA 93727 Phone # (209) 487-5785, Ext 130 Don't delay, start today!!! Sincerely, Steve Underwood Underground Storage Tank Inspector Office of Environmental Services cc: Ralph Huey BAKERSFIELD FIRE DEPARTMENT January 27, 1998 Mr. Charles McCan Wholesale Fuels, Inc. FIRE CHIEF MICHAELR. KELLY P.O. Box 70097 Bakersfield, Ca 93387-0097 ADMINffii'I~TIVE ~ER'VICE~ 2101 'H" Street Bakersfield, CA93301 RE: 2200 East Brundage Lane (805) 326-3941 FAX (805) 395-1349 UNDERGROUND STORAGE TANK UPDATE SUPPRESSION SERVICES 2101 'H" Street Bakersfield, CA 93301 Dear Mr. McCan: (805) 326-3941 FAX (805) 395-1349 The City of Bakersfield wishes to congratulate those tank owners who .~:VENnON SE~C~S have upgraded, removed or replaced their, tanks in the month of January. During 1715 Chester Ave. Bakersfield, CA 93301 the month of January, our office had six sites (l 4 tanks) which are now in (805) 326-3951 compliance. This is a very big "first step". FAX (805) 326-0576 ENVi[K)NMEN'rALSEIWICES For those who have not yet upgraded, I would like to share some thoughts 1715 Chestm Ave. on why it is so important to act right away: Bakersfield, CA 93~1 (805) 326-3979 FAX C805)326-0576 1. Licensed contractors are booking up fast, in some cases, up TRAINING DIVISION to three months in advance. " 5642 Victor Street 2. Supplies (pumps, dispensers, leak detection equipment) Bakersfield, CA 93308 (805) 399-4697 may be scarce. FAX C805) 399-5763 3. The cost for upgrading or removing could go up as demand increases. 4. Assembly Bill 1491 will ban fuel deliveries after January 1999 to non-upgraded owners. The good news, is there is still time!!! If there is anything this office can do to assist you in your planning, do not hesitate to call. Sincerely, Ralph E. Huey Hazardous Materials Coordinator Office of Environmental Services cc: Kirk Blair, Assistant Chief BAKERSFIELD FIRE DEPARTMENT December 18, 1997 FIRE CHIEF MICHAEL R. KELLY Mr. Charles McCan Wholesale Fuels, Inc. ADMINISTRATIVE~ERVICF~ P.O. Box 70097 2101 *H° Street Bakersfield, CA93801 Bakersfield, CA 93387-0097 (805) 326-394 FAX (805) 395-1349 RE: 2200 East Brundage Lane SUPPI~SSION SERVICES 2101 'H' Bake~fleld, CA 93801 Dear Mr. McCan: (805) 326-3941 FAX (805) 395-1349 You will be receiving this letter on or about December 22, 1997. One PI1EVENTION SEIi~CE$ year from today, December 22, 1998, your current underground storage tanks will 1715 Chester Ave. become illegal to operate. Current law would require that your permit be revoked Bakersfield, CA 93801 (805) 326-3951 and, would make it illegal for any fuel distributer to deliver to any non upgraded FAX (805) 326-0576 tanks ENVIRONMENTAL SERVICES 1715 Chester Ave. However, in reviewing your file I see that you do plan to replace your Bakersfield, CA 93301 (805) 326-3979 tanks by June, 1998. We congratulate you on your decision to replace your tanks FAX (805)3260576 and simply want to offer any assistance we can in meeting your target date. Please remember to contact this office for permits well in advance of your TRAINING DIVISION 5642 Victor Street anticipated start date. As we get closer to the December 22, 1998 date, I would Bakersfield, CA93308 expect construction lead times to become extended, as well as costs for tank (805) 399-4697 FAX (805) 399-5768 renlacements. Sincerely, Hazardous Materials Coordinator REH/dm cc: Kirk Blair, Assistant Chief BAKERSFIELD FIRE DEPARTMENT June 3, 1997 n~ C.IEF M r. Charles McCan MICHAEI.R. KELLY Wholesale Fuels, Inc. P.O. Box 70097 ADMINISTRA~VE SERVICES 2'~m 'H' s'.eet Bakersfield, CA 93387-0097 Bakersfield, CA 98301 (805) 326-3941 FAX (805) 395-1349 RE: Waste Oil Tank Removal and Site Characterization at 2200 E. Brundage Lane. SUPPRESSION SERVICES 2101 'H' Street Dear Mr. McCan: Bakersfield, CA 93301 (805) 326-3941 FAX (805)395-1349 OUr records indicate that your former underground storage tank site is currently subject to Corrective Action Requirements under Article ! 1 of Title 23 California Code of Regulations n~,m~o, sE~lC~S concemintz leaking undert~round tanks. 1715 Chester Ave. ~ ~ Bakersfield, CA 93301 (805) 326-3951 FAX(805) 326-0576 Accordingly, pursuant to Section 2722(b) of Article I I, yeLl are hereby directed to begin the necessan.., work at your site within 90 calendar days from the date of this letter. The required ENVIRONMENTAL SERVICE$ work shall include: 1715 Chester Ave. Bakersfield; CA 93301 (1305) 326.3979 Submission of the results of the site characterization pertbrmed on September 12, 1996 by FAX (805) 326421576 - Hansen Engineering in a tbnnat consistent with Regional Water Board recommendations tbr TRAINING DIVISION prelimina~ evaluation and investigation of underground tank sites. 5642 Victor Street Bakersfield, CA 93308 (805) 399-4697 Please be aware that, pursuant to Section 2722(c) of Article i I, you are required to have an FAX (805) 39%5763 approved workplan on tile with this office prior to initiation of any corrective action work In addition, you are to provide ongoing status reports of all activities involving tile progress of this case to this office every. 90 days. If you have any questions regarding the provisions of this letter, please call me at 326-3979. Sincerely, Howard H. Wines, 1Ii Hazardous Materials Technician HHW/dhn cc: J. Hansen BAKERSFIELD FIRE DEPARTMENT December 4, 1996 n.E C.IEF McCan & Jamieson MICHAEL R. KELLY P.O. Box 70097 Bakersfield, CA 93387-0097 ADMINISTRATIVE SERVICES 2101 'H' Street Bakersfield, CA 93301 (805) 326-3941 RE: Underground Storage Tanks located at Wholesale Fuels Inc., 2200 East FAX (805)395-1349 Brundage Lane in Bakersfield. SUPPRESSION SERVICES 2101 'H' Street Dear Mr. McCan & Mr. Jamieson: Bakersfield, CA 93301 (805) 326-3941 FAX (805)395-1349 AS I am sure you are aware, all existing single walled steel tanks that do not meet the current code requirements must be removed, replaced or upgraded to PREVENTION SERVICES meet the code by December 22, 1998. Your tanks do not currently meet the new 1715 Chester Ave. Bakersfield. CA 93301 code requirements and therefore fall into the remove, replace or upgrade category. (805) 326-3951 FAX (806) 326-0576 Your current operating permit expires on or before that date and of course will not be renewed until appropriate upgrade of your tank system is accomplished. ENVIRONMENTAL SERVICES 1715 Chester Ave. BakersfielO. CA 93301 In order to assist you and this office in meeting this fast approaching (805) 326-3979 deadline, I have attached a brief questionnaire addressing your plans to upgrade FAX (805) 32643576 these tanks. Please complete this questionnake and return it to this office by TRAINING DIVISION Thursday, December 1 9, 1 996. 56~2 Victor Street Bakersfield, CA 93308 (805) 399-4697 If yOU have any questions concerning your tanks or if we can be of any FAX (805) 399-5763 assistance, please do not hesitate to contact this office. Sincerely, Ralph E. Huey Hazardous Materials Coordinator Office of Environmental Services REH/dlm attachment MEMORANDUi~ CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD - CENTRAL VALLEY REGION 3614 East Ashlan Avenue Phon~: (209) 445-5116 Fresno, CA 93726 Al'SS Phone: 8-421-5116 TO: F. SCOTT NEVINS FROM: ROBERTA C. HOWE Senior Engineer Staff Engineer DATE: 27 November lggo SIGNATURE: SUBJECT: CLOSURE OF THE WHOLESALE FUELS, INC. SUMP, BAKERSFIELD, KERN COUNTY COMMENTS: I have reviewed the 15 January 1990 Closure Report prepared by Mr. Russell Juncal, R.G. {No. 3864) of WaterWork for the Wholesale Fuels, Inc. sump. The closure involved removing the contaminated materials from the sump, spreading the excavated materials on site and grading the spreading area to prevent ponding, and filling the excavation with clean soil brought from off site. We reviewed the post-excavation soils sampling results in November 1989, and indicated that backfilling of the excavation with clean soils could proceed. We recommended that the area above the former sump be graded to prevent ponding and requested that the closure report include documentation of the source of the fill material and the results of chemical analyses of the fill material. The Closure Report indicates the fill was obtained from the Gateway development on Mt. Vernon (across Highway 58 from the site), and includes the results of the chemical analyses of the soil. The analytical results indicate the metals concentrations in the fill material are within the ranges typically found in natural soils. There were no PCBs found in the soil at a detection limit of 0.0002 ug/g. According to the Closure Report, the fill was transported to the sump area and placed in the excavated area in layers approximately 2-feet thick. The lifts were compacted with a rubber-tired loader. Upon completion of the backfill and ~compaction, the area was graded to prevent ponding. The Closure Report also indicates that if settling is noted in the future, the area will be graded as necessary. The information provided in the Closure Report is satisfactory. INSPECTION REPORT: On 16 November 1990, I inspected the Wholesale Fuels, Inc. facility at 2200 E. Brundage Lane, Bakersfield. I was accompanied by Mr. Terry Olgilvie of Wholesale Fuels, Inc. The area formerly occupied by the sump is level with the surrounding area. The soils appeared to be well-compacted, and Mr. Olgilvie stated that a binder had been added to the soils at the surface to reduce dust. I observed no discolored soils at the former sump area. Maintenance of the area appeared to be adequate. HHOLESALE FUELS, INC. SUNP -2- 27 November 1990 CONCLUSIONS: The closure of the Nholesale Fuels, Inc. sump has been completed and appears to be adequate. No further work is necessary at this time. RCH:rch/fmc STATE OF CALl FORNIA GE DEUKMEJIAN, Governor CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD--. CENTRAL VALLEY REGION .... SAN JOAQUIN WATERSHED BRANCH OFFICE: *-~.. 3614 EAST ASHLAN AVENUE PHONE: (209) 445-5116 27 November 1989 ~>'~%"-'x~,~/ Mr. Charles McCan Wh61~sale Fuels~ Inc. 2200 East Brundage Lane Bakersfield, California 93307 WHOLESA[E]FUELS,.¥~NC~SUMP~ KERN COUNTY We have evaluated the post-excavation soil sampling results that were provided to us by Mr. Russell Juncal of WaterWork for the Wholesale Fuels, Inc., sump. Enclosed is a memorandum with our comments and recommendations. Please note that the excavation may be filled with clean soils. Upon completion of backfilling the excavation, and compaction of the fill material, the area over the sump should be graded to prevent ponding. In addition, our review of the Closure Plan for the sump requested that documentation regarding the source of the fill dirt and the results of chemical analysis of the fill dirt be included in the closure report. Prior to 15 January 1990, please provide us with a report of the sump closure. Should you have any questions, please telephone Roberta Howe of this office at (209) 488-4393. F.SCOTT NEVINS Senior Engineer RCH:rch:bro Enclosure cc: Kern County Health Department, Bakersfield Mr. Russell W. Ouncal, WaterWork, Escalon Memorandum CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD eCENTRAL VALLEY REGION 3614 E. Ashlan SAN JOAQUIN WATERSHED BRANCH Telephone: (209) 445-5116 Fresno, CA 93726-6905 State Lease Line: 421-5116 TO: F. Scott Nevins FROM: Roberta C. Howe Senior Engineer Staff Engineer DATE: 27 November 1989 SIGNATURE: ~ C. ~ SUBJECT: POST-EXCAVATION SAMPLING RESULTS FOR THE WHOLESALE FUELS, INC. SUMP, KERN COUNTY COMMENTS I have reviewed the post-excavation sampling results for the Wholesale Fuels, Inc. sump in Bakersfield, California. The information was submitted by Mr. Russell W. Juncal, R.G. (No. 3864, expiration date 6/30/g0) of WaterWork. INTRODUCTION Wholesale Fuels, Inc. is a petroleum jobber facility operating at 2200 E. Brundage Lane, Bakersfield, California. As part of the facility's past operations, a sump on the north side of the property was used as a collection area to receive rinse water from external vehicle washing. Rainwater washing oil off drums, storm water runoff, and possible spillage may have also entered the sump. Wholesale Fuels, Inc. was notified by State Water Resources Control Board staff that this surface impoundment might be subject to the Toxic Pits Cleanup Act of 1984 (TPCA). Wholesale Fuels, Inc. demonstrated that the levels of chemicals in the sump were not hazardous. Thus, we concluded that the sump was not subject to the TPCA. However, as the concentrations of some of the chemicals present in the bottom of the sump were higher than Acceptable Drinking Water Levels and were thought to pose a threat to ground water quality, we requested that Wholesale Fuels, Inc. develop a closure plan for the sump. The Closure Plan for the Wholesale Fuels, Inc. sump, prepared by WaterWork, proposed excavating the contaminated soils from the sump, spreading these soils on-site, and backfilling the excavated area with clean soil. According to the WaterWork letter of transmittal for the post-excavation soil sampling results, the material removed from the sump has been spread on-site and has been graded to prevent ponding. WaterWork also requested written authorization to backfill the excavation with clean fill material.