Loading...
HomeMy WebLinkAboutBUSINESS PLAN DATE ,.~, ADqRESS ZIP CODE FEE I BLOCK NO. i~US~N~S~ L~CENS~ NO. PERMIT REQUmED P~RM~T NO. ~~~ ~Y- t-~ "YES ~ NO-~ ~" BUILDING CLASS/TYPE OF OCCUPANCY )usI~E~S NAME ~¢}h '-. ~S~O . ~XV~-~~' BUSINESS OWNER BUSINESS ~GR,/RESPONSIBLE VIOLATION NOTICE ISSUED? OCCUPANT LOAD OTHER DATE OF REINSPECTION (1) (2) (3) ~SPECTOR STATION/SHiFT/STATION PHONE ~ HAZARDOUS MATERIALS INSI~TION i Bakersfield FJLre Dept.- 07~ICE OF ENVIRONMENTAL SERVICES 1715 Chester Av~. f,~X.~L,~" L~ ~ 5 X~ ~ B~ersfield, CA93301 Sta~on No. ~' Shift ~ Inspector Arrival Time: DepaAure Time: Inspection Time: Adequate Inadequate Adequate Inadequate Address Visable I'1 [] Emergency Procedures Posted [] [] Correct Occupancy [] [] Containers Propedy Labled El [] Verification of Inventory Materials [] [] Comments: Verification of Quantities [] [] Verification of Location [] [] Verification of Facility Diagram r'l [] Proper Segregation of Material [] [] Housekeeping [] [] Fire Protection [] [] Comments: Electrical [] [] Comments: Verification of MSDS Availablity [] [] Number of Employees: UST Monitoring Program [] [] Comments: Verification of Haz Mat Training [] [] Permits [] [] Comments: Spill Control El [] Hold Open Device [] [] Verification of Hazardous Waste EPA No. Abbatement Supplies and Procedures El [] Proper Waste Disposal El El Comments: Secondary Containment [] [] Security El [] Special Hazards Associated with this Facility: Violations: / All Items O.K [] Business Owner/Manager PRINT NAME SIGNATURE Correction Needed [] White-Haz Mat Div. Yellow-Station Copy Pink-Business Copy BA~ERSFIELDx WELL AND PUMP CO I ~~7~~,, ~- SiteID: 215-000-001351 Manager : ~Phone: (805) 324-6026 Location: 1600 E CALIFORNIA A\ : 103 CommHaz : Moderate City : BAKERSFIELD ....... ~~id: 33A FacUnits: 1 AOV: CommCode: COUNTY STATION 41 SIC Code: EPA Numb: DunnBrad: Emergency Contact / Title Emergency Contact / Title JOHN ZIMMERER / VP OPERATION DENNIS MCKINDLEY / MANAGER Business Phone: (805) 324-6026x Business Phone: (805) 324-6026x 24-Hour Phone : (805) 588-1766x 24-Hour Phone : (805) 322-7971x Pager Phone : (805) 329-0836x Pager Phone : (805) 329-0782x Hazmat Hazards: Fire Press ImmHlth DelHlth Agency-Defined Topic Title ---- Hazmat Inventory One Unified List -- MCP+DailyMax Order Ail Materials at Site Hazmat Common Name... ISpocHaz[EPA HazardsI Frm DailyMax UnitlMcP ACETYLENE F P IH G 800 FT3 Hi OXYGEN F P IH G 600 FT3 Low WASTE OIL F DH L 500 GAL Low ANTIFREEZE F DH L 55 GAL Low NITROGEN F P IH G 900 FT3 Min ARGON F P IH G 349 FT3 Min MOTOR OILS F DH L 330 GAL Min ~, DENNIS MC K.INDLE~© BAKE'RSFIELD WELL~& PUMP, Div. of msm p~a~~ Zim Ind. ~ Inq_~ ~~__ DE~IS NC KI~DLEY: 2~ Hr. Phone: 22-7179~ Pager: 329-3969~~~ CHASGE OF ADDRESS: 7212 FruStvale. Ave~ BakersfSeld~ CA 93308 TELEPHONE: (805) 393-9661 -1- 09/16/1997 BAKERSFIELD WELL AND PUMP CO INC SiteID: 215-000-001351 ~ Inventory Item 0004 Facility Unit: Fixed Containers on Site ACETYLENE Days On Site 365 Location within this Facility Unit r STATE ~ TYPE PRESSURE ?EMPE~TURE CONTA,N~R TYPE AMO~TS AT THIS LOCATION Largest Container { Daily Maximum Daily Average FT3I 800.00 FT3 500.00 FT3 HAZARDOUS COMPONENTS %Wt. Acetylene EHS CAS# 100.00 No 74862 HAZARD ASSESSMENTS TSecret EHS BioHaz Radioactive/Amount EPA Hazards NFPA USDOT# MCP No INo I No No/ Curies F P IH / / / Hi ~ Inventory Item 0005 Facility Unit: Fixed Containers on Site ~UtV~VlU~ ~Vl~ / ~±~_/.-~3_~ ~Vl~ OXYGEN Days On Site 365 Location within this Facility Unit O/S ,~ CORNER MAIN SHOP1 ~ ~ ~~ CAS# ~ " ~_~7~ ~J~"/~'~ ~ 7782-44-7 ~ STATE -- TYPE PRESSURE TEMPERATURE CONTAINER TYPE Pure Above Ambient PORT PRESS CYLINDER Gas Cryogenic . . AMOUNTS AT THIS LOCATION Largest Container [ Daily Maximum Daily Average FT3I 600.00 FT3 400.00 FT3 HAZARDOUS COMPONENTS %Wt. { EHS CAS# 100.001Oxygen, Compressed No 7782447 EHS BioHazI HAZARD AiSESSMENTS TSecret Radioactive/Amount EPA Hazards NFPA USDOT# MCP No No No No/ Curies F P IH / / / Low 2 09/16/1997 BAKERSFIELD WELL AND PUMP CO INC SiteID: 215-000-001351 ~ Inventory Item 0003 Facility Unit: Fixed Containers on Site WASTE OIL Days On Site 365 Location within this Facility Unit Liquid /Waste I Ambient I Ambient [ ABOVE GROUND TANK AMOUNTS AT THIS LOCATION Largest Container Daily Maximum I Daily Average GAL 500.00 GAL 100.00 GAL HAZARDOUS COMPONENTS %Wt. EHS CAS# 100.00 Waste Oil, Petroleum Based No 0 HAZARD ASSESSMENTS TSecret EHS BioHaz Radioactive/Amount EPA Hazards NFPA I USDOT# MCP No No No No/ Curies F DH / / /I Low ~ Inventory Item 0002 Facility Unit: Fixed Containers on Site ~UIVHVlU~ ~vl~ / ~ £ ~,--I-~ ~Vl~ ANTIFREEZE Days On Site 365 Location within this Facility Unit  ~vj~5~ , CAS# F STATE TYPE PRESSURE TEMPERATURE CONTAINER TYPE Liquid Pure AmBient Below Ambient DRUM/BARREL-METALLIC AMOUNTS AT THIS LOCATION -- Largest Container [ Daily Maximum Daily Average GAL 55.00 GAL 55.00 GAL HAZARDOUS COMPONENTS %Wt. [ EHS CAS# 100.001Ethylene Glycol No 107211 HAZARD ASSESSMENTS TSecret EHS BioHaz Radioactive/Amount EPA Hazards NFPA USDOT# MCP No No No No/ Curies F DH / / / Low 3 09/16/1997 BAKERSFIELD WELL AND PUMP CO INC SiteID: 215-000-001351 = Inventory Item 0006 Facility Unit: Fixed Containers on Site NITROGEN Days On Site 365 Location within this Facility Unit O/S ~5~CORNER MAIN SHOP1 CAS# Gas Pure Above Ambient Below Ambient PORT. PRESS. CYLINDER I AMOUNTS AT THIS LOCATION Largest Container Daily Maximum Daily Average FT3 900.00 FT3 500.00 FT3 HAZARDOUS COMPONENTS %Wt. EHS CAS# 100.00 Nitrogen No 7727379 HAZARD ASSESSMENTS TSecret EHS BioHaz Radioactive/Amount EPA Hazards NFPA USDOT# I MCP No No No No/ Curies F P IH / / /I Min ~ Inventory Item 0007 Facility Unit: Fixed Containers on Site ~UlVUVl~ ~Vl~ / ~I~A_.I_~ ~Vl~ ARGON Days On Site 365 Location within this Facility Unit Gas Pure Above Ambient Below Ambient PORT. PRESS. CYLINDER AMOUNTS AT THIS LOCATION Largest Container I Daily Maximum I Daily Average FT3I 349.00 FT3I 349.00 FT3 HAZARDOUS COMPONENTS %Wt. EHS CAS# 100.00 Argon No 7440371 HAZARD ASSESSMENTS TSecret EHS BioHaz Radioactive/Amount EPA Hazards NFPA USDOT# MCP No No No No/ Curies F P IH / / / Min -4- 09/16/1997 BAKERSFIELD WELL AND PUMP CO INC SiteID: 215-000-001351 ~ Inventory Item 0001 Facility Unit: Fixed Containers on Site MOTOR OILS Days On Site 365 Location within this Facility Unit Liquid Pure Ambient Ambient METAL CONTAINR-NONDRUM AMOUNTS AT THIS LOCATION Largest Container I Daily Maximum Daily Average .G.i~LI 330.00 GAL 300.00 GAL I HAZARDOUS COMPONENTS %Wt. EHS CAS# 100.00 Motor Oil, Petroleum Based No 8020835 HAZARD ASSESSMENTS TSecret EHS BioHaz Radioactive/Amount EPA Hazards NFPA USDOT# MCP No No No No/ Curies F DH / / / Min -5- 09/16/1997 F BAKERSFIELD WELL AND PUMP CO INC SiteID: 215-000-001351 Fast Format ~ Notif./Evacuation/Medical Overall Site --Agency Notification 01/24/1996 CALL 911 -- Employee Notif./Evacuation 01/24/1996 SHOULD AN INCIDENT OCCUR WE HAVE A SPEAKER AND BUZZER SYSTEM TO NOTIFY OUT EMPLOYEE'S OF ANY PROBLEM. -- Public Notif./Evacuation 01/24/1996 NONE LISTED Emergency M~diC~l Plan 01/24/1996 \/ VALLEY INDUSTRIAL~EDICAL GROUP - 2501 G ST - 327-2225. BUSINESSHEALTH NET~/ORK: 2811 H Street~ gakersfield~ CA 93303 (805) 321-3781 6 09/16/1997 BAKERSFIELD WELL AND PUMP CO INC SiteID: 215-000-001351 Fast Format ~ Mitigation/Prevent/Abatemt Overall Site -- Release Prevention 01/07/1990 MOTOR OILS ARE STORED IN DISPENSING TANKS, SERVICED AND MAINTAINED BY SUPPLIER. COMPRESSED GAS CYLINDERS ARE STORED SEPERATELY IN RACKS AND CHAINED SECURELY. --Release Containment -- Clean Up Other Resource Activation -7- 09/16/1997 BAKERSFIELD WELL AND PUMP CO INC SiteID: 215-000-001351 Fast Format ~ Site Emergency Factors Overall Site -- Special Hazards -- Utility Shut-Offs 01/07/1990 . C)~WATER---~- ~u~WEST COR/~ER OF ~...~C.; (PlCUO & SON PA~±NG LOx')~u~~ D) SPECIAL - NONE E) LOCK BOX - NO -- Fire Protec./Avail. Water 01/07/1990 PRIVATE FIRE PROTECTION - FIRE EXTINGUISHERS PLACED THROUGHOUT OUR FACILITY. ~TRE-~DRANT -~.~RTHEAST CORi~.,~ o~' CALIFORNIA & wiLLI~4S ~~ Building Occupancy Level 8 09/16/1997 F.~ARERSFIELD WELL AND PUMP CO INC SiteID: 215-000-001351 Fast Format ~ Training Overall Site -- Employee Training 05/01/1991 WE HAVE~ EMPLOYEES AT THIS FACILITY WE HAVE MATERIAL SAFETY DATA SHEETS ON FILE BRIEF SUMMARY OF TRAINING: -- Page 2 I -- Held for Future Use I Held for Future Use 9 09/16/1997 )1/11/~96 BAKERSFIELD WELL AND PUMP CO INC 215-000 '~¥, ~Page Overall Site with 1 Fac. Unit ~ General Information .~ > Location: 1600 E CALIFORNIA AV Map:103 Haz:3 Type: 3 City : Bakersfield Grid: 33A F/U: 1 AOV: 0.0 Contact Namel/~__ ~ ·. Title ~ i-- Contact Name Title JOHN ZI ERER / Business Phone: (805) 324-6026x Business Phone: (805) 324-6026x 24-Hour Phone : (805) ~~$~-/~ 24-Hour Phone : (805) Pager Phone : (~SJ 3~$ ~%x Pager Phone : (~5~) Administrative Data Mail Addrs: 1600 E CALIFORNIA AV D&B Nu~er: City: BAKERSFIELD State: CA Zip: 93307- Co~ Code: 215-041 COUNTY STATION 41 SIC Code: Owner: JOHN ZI~ERER Phone: (805) Address: ~01 ~O~t~ D~ State: CA City: BAKERSFIELD Zip: 93~ Sugary I. ~L~-~.~,~erc, v~ Do hereby certify that I have reviewed the attached hazardous_materials mahage- men, plan ,or_~.~.~&.~,!l~r~cl"[h~ ,, along with any corrections constitute a complete and correct man- agement 01/11/96 BAKERSFIELD WELL AND PUMP CO INC 215-000-001351 Page 2 Hazmat Inventory List in MCP Order 02 - Fixed Containers on Site Pln-Ref Name/Hazards Form Max Qty MCP 02-004 ACETYLENE Gas 800 High · Fire, Pressure, Immed Hlth FT3 02-002 ANTIFREEZE Liquid 55 Low · Fire, Delay Hlth GAL 02-005 OXYGEN Gas 600 Low · Fire, Pressure, Immed Hlth FT3 02-003 WASTE OIL Liquid 500 Low · Fire, Delay Hlth GAL 02-007 ARGON Gas 349 Minimal · Fire, Pressure, Immed Hlth FT3 02-001 MOTOR OILS Liquid 330 Minimal · Fire, Delay Hlth GAL 02-006 NITROGEN Gas 900 Minimal · Fire, Pressure, Immed Hlth FT3 01/11/96 BAKERSFIELD WELL AND PUMP CO INC 215-000-001351 Page 3 02 - Fixed Containers on Site Hazmat Inventory Detail in MCP Order 02-004 ACETYLENE Gas 800 High ~ Fire, Pressure, Immed Hlth FT3 CAS #: 74-86-2 Trade Secret: No Form: Gas Type: Pure Days: 365 Use: WELDING SOLDERING Daily Max FT3 I Daily Average FT3 I Annual Amount FT3 800 ~ 500.00 800.00 Storage Press T TempI Location PORT. PRESS. CYLINDER Above ~Below IO/S NE CORNER MAIN SHOP1 -- Conc I Components MCP ---~uide 100.0%~lAcetylene High ~ 17 02-002 ANTIFREEZE Liquid 55 Low ~ Fire, Delay Hlth GAL CAS #: 107-21-1 Trade Secret: No Form: Liquid Type: Pure Days: 365 Use: COOLANT/ANTIFREEZE Daily Max GALI Daily Average GAL I Annual Amount GAL 55 ~ 55.00 110.00 Storage Press T TempI Location DRUM/BARREL-METALLIC Ambient~Below INE CORNER WAREHOUSE 2 -- ConcI Components MCP ---~uide 100.0% IEthylene Glycol Low ~ 27 02-005 OXYGEN Gas 600 Low ~ Fire, Pressure, Immed Hlth FT3 CAS #: 7782-44-7 Trade Secret: No Form: Gas Type: Pure Days: 365 Use: OTHER Daily Max FT3I Daily Average FT3 I Annual Amount FT3 600 ~ 400.00_ 600.00 ~torage I Press T TempI Location PORT. PRESS. CYLINDER .lAbove lCryogenlO/S NE CORNER MAIN SHOP1 -- Conc Components MCP ---~Guide 100.0% }Oxygen, Compressed ILow ~ 14 01/11/96 BAKERSFIELD WELL AND PUMP CO INC 215-000-001351 Page 4 02 - Fixed Containers on Site Hazmat Inventory Detail in MCP Order 02-003 'WASTE OIL Liquid 500 Low · Fire, Delay Hlth GAL CAS #: 221 Trade Secret: No Form: Liquid Type: Waste Days: 365 Use: WASTE Daily Max GAL I Daily Average GAL I Annual Amount GAL -- 500 ~ 100.00 1,000.00 Storage ~ Press T Temp~ Location ABOVE GROUND TANK IAmbientlAmbientlOUTSIDE E WALL MAIN SHOP -- ConcI Components I MCP ---/Guide 100.0% IWaste Oil, Petroleum Based ILow ! 27 02-007 ARGON Gas 349 Minimal · Fire, Pressure, Immed Hlth FT3 CAS #: 7440-37-1 Trade Secret: No Form: Gas Type: Pure Days: 365 Use: WELDING SOLDERING Daily Max FT3I Daily Average FT3 ] Annual Amount FT3 349 I 349.00 349.00 Storage Press T TempI Location PORT. PRESS. CYLINDER Above ~Below II/S SHOP NW CORNER 1 ~' Conc I Components MCP ---~uide 100.0%~Argon Minimal I 12 02-001 MOTOR OILS Liquid 330 Minimal · Fire, Delay Hlth GAL CAS #: 64742-41-2 Trade Secret: No Form: Liquid Type: Pure Days: 365 Use: LUBRICANT Daily Max GALI Daily Average GAL I Annual Amount GAL -- 330 ~ 300.00 600.00 Storage Press T TempI Location METAL CONTAINR-NONDRUM AmbientlAmbientlNW CORNER WAREHOUSE 2 -- ConcI ComponentsI MCP ---~uide 100.0% IMotor Oil, Petroleum Based IMinimal ~ 27 01/11/96 BAKERSFIELD WELL AND PUMP CO INC 215-000-001351 Page 5 02 - Fixed Containers on Site Hazmat Inventory Detail in MCP Order 02-006 NITROGEN Gas 900 Minimal · Fire, Pressure, Immed Hlth FT3 CAS #: 7727-37-9 Trade Secret: No Form: Gas Type: Pure Days: 365 Use: WELL INJECTION OR SERVICE Daily Max FT3 I Daily Average FT3 I Annual Amount FT3 900 ~ 500.00 900.00 Storage i Press T Temp~ Location PORT. PRESS. CYLINDER IAbove /Below IO/S NE CORNER ~IN S~OP1 -- Conc Components MCP Guide 100.0% INitrogen IL°w I 12 01/11/96 BAKERSFIELD WELL AND PUMP CO INC 215-000-001351 Page 6 00 - Overall Site <D> Notif./Evacuation/Medical <1> Agency Notification CALL 911 <2> Employee Notif./Evacuation SHOULD AN INCIDENT OCCUR WE HAVE A SPEAKER AND BUZZER SYSTEM TO NOTIFY OUT EMPLOYEE'S OF ANY PROBLEM. <3> Public Notif./Evacuation NONE LISTED <4> Emergency Medical Plan VALLEY INDUSTRIAL MEDICAL GROUP 2501 G STREET BAKERSFIELD, CA. 93301 (805) 327-2225 01/11/96 BAKERSFIELD WELL AND PUMP CO INC 215-000-001351 Page 7 00 - Overall Site <E> Mitigation/Prevent/Abatemt <1> Release Prevention MOTOR OILS ARE STORED IN DISPENSING TANKS, SERVICED AND MAINTAINED BY SUPPLIER. COMPRESSED GAS CYLINDERS ARE STORED SEPERATELY IN RACKS AND CHAINED SECURELY. <2> Release Containment <3> Clean Up <4> Other Resource Activation 01/11/96 BAKERSFIELD WELL AND PUMP CO INC 215-000-001351 Page 8 00 - Overall Site <F> Site Emergency Factors <1> Special Hazards <2> Utility Shut-Offs A) GAS - SOUTHWEST CORNER OF MAIN SHOP (OUTSIDE) B) ELECTRICAL - SOUTHWEST CORNER OF MAIN SHOP INSIDE WALL C) WATER - NORTHWEST CORNER OF FENCE (PICCO & SON PARKING LOT) D) SPECIAL - NONE E) LOCK BOX - NO <3> Fire Protec./Avail. Water PRIVATE FIRE PROTECTION - FIRE EXTINGUISHERS PLACED THROUGHOUT OUR FACILITY. FIRE HYDRANT - NORTHEAST CORNER OF CALIFORNIA & WILLIAMS <4> Building Occupancy Level 01/11/96 BAKERSFIELD WELL AND PUMP CO INC 215-000-001351 Page 9 00 - Overall Site <G> Training <1> EmplOyee Training WE HAVE 20 EMPLOYEES AT THIS FACILITY WE HAVE MATERIAL SAFETY DATA SHEETS ON FILE BRIEF SUMMARY OF TRAINING: <2> Page 2 <3> Held for Future Use <4> Held for Future Use 06/30/93 AK RSFIELD WELL AND PUMP CO 215-000.-001351 Page 1 Overall Site with 1 Fac. Unit General Information Location: 1'600 E CALIFORNIA AV Map: 103 Hazard: Moderate COmmunity: COUNTY STATION 41 Grid: 33A F/U: 1 AOV: 0.0 Contact Name~ Title Business Phone 24-Hour Phone, JOHN j Zimme.rer ~,', ~1 Vice President 1(805) (805) 324-6026 x (805) 873-9033.1 JOE LOPEZ I ~ 324-6026 x (805) 399-8025 Administrative Data Mail Addrs: 1600 E CALIFORNIA AV D&B Number: City: BAKERSFIELD State: CA Zip: 93307- Comm Code: 21.5-.041 COUNTY STATION 41 SIC Code: Owner: John Zimmerer~ Phone: (805) 873~9033~ Address: '6_~"A~bur~ #169~ State: CA City: BAKERSFIELD Zip: 93306- Summary RECEIVED JUL 0 8 .lYY~ HAZ. MAL DI~ I, John Zimmerer Do hereby certify that I have · (TY~ Or ,o'.nt reviewed the a~ached hazardous materials manage- Bakersfield Well ment p~an ~or & Pump co. and that it a~0n§ wi~b - (Name 0f'Busineaaj -- any corrections constitute a complete and correct man- agement plan for my facility~ 06/30/93 BAKERSFIELD WELL AND PUMP CO --' 215-000-001351 Page 2 Hazmat Inventory List in MCP Order 02 - Fixed Containers on Site Pln-Ref Name/Hazards Form Max Qty MCP 02-004 ACETYLENE Gas 800 High · Fire, Pressure, Immed Hlth FT3 02-002 ANTIFREEZE Liquid 55 Low · Fire, Delay Hlth GAL 02-005 OXYGEN Gas 600 Low · Fire, Pressure, Immed Hlth FT3 02-003 WASTE OIL Liquid 500 Low · Fire, Delay Hlth GAL 02-007 ARGON Gas 349 Minimal · Fire, Pressure, Immed Hlth FT3 02-001 MOTOR OILS Liquid 330 Minimal · Fire, Delay Hlth GAL 02-006 NITROGEN Gas 900 Minimal · Fire, Pressure, Immed Hlth FT3 06/30/93 BAKERSFIELD WELL AND PUMP CO 215-000-001351 Page 3 02 - Fixed Containers on Site Hazmat Inventory Detail in MCP Order 02-004 ACETYLENE Gas 800 High · Fire, Pressure, Immed Hlth FT3 CAS #: 74-86-2 Trade Secret: No Form: Gas Type: Pure Days: 365 Use: WELDING SOLDERING Daily Max FT3I Daily Average FT3 I Annual Amount FT3 -- 800 ~ 500.00 800.00 StorageI Press T TempI Location PORT. PRESS. CYLINDER IAbove JBelow IO/S NE CORNER MAIN SHOP1 -- Conc Components MCP ---~Guide 100.0% IAcetyiene IHigh ! 17 02-002 ANTIFREEZE Liquid 55 Low · Fire, Delay Hlth GAL CAS #: 107-21-1 Trade Secret: No Form: Liquid Type: Pure Days: 365 Use: CooLANT/ANTIFREEZE Daily Max GALI Daily Average GAL I Annual Amount GAL 55 I 55.00 110.00 Storage Press T Temp Location DRUM/BARREL-METALLIC IambientJBelow INECORNER WAREHOUSE 2 -- Conc Components MCP ---~uide 100.0% IEthylene Glycol ILow ! 27 02-005 OXYGEN Gas 600 Low · Fire, Pressure, Immed Hlth FT3 CAS #: 7782-44-7 Trade Secret: No Form: Gas Type: Pure Days: 365 Use: OTHER Daily Max FT3I Daily Average FT3 I Annual Amount FT3 600 ~ 400.00 600.00 StorageI Press T TempI L°cati°'n PORT. PRESS. CYLINDER IAbove /CryogenlO/S NE CORNER MAIN SHOP1 -- Conc Components MCP ---TGuide 100.0% IOxygen, Compressed [Low ~ 14 06/30/93 BAKERSFIELD WELL AND PUMP CO ~ 215-000-001351 Page 4 02 - Fixed Containers on Site Hazmat Inventory Detail in MCP Order 02-003 WASTE OIL Liquid 500 Low · .Fire, Delay Hlth GAL CAS #: 221 Trade Secret: No Form: Liquid Type: Waste Days: 365 Use:. WASTE Daily Max GALI Daily. Average GAL I Annual ;~nount GAL 500 ~ 100.00 1,000.00 Storage Press T TempI Location ABOVE GROUND TANK AmbientmAmbientlOUTSIDE E WALL MAIN SHOP -- Conc{ Components{ MCP --rGuide 100.0% IWaste Oil, Petroleum Based IL°w I' 27 02-007 ARGON Gas 349 Minimal · Fire, Pressure, Immed' Hlth FT3 CAS #: 7440-37-1 Trade Secret: No Form: Gas TYpe: Pure Days: 365 Use: WELDING SOLDERING Daily Max FT3I Daily Average FT3 { Annual Amount FT3 -- 349 I 349.00 349.00 Storage I Press 7 Tomp I Location PORT. PRESS. CYLINDER Above ~Below I/S SHOP NW CORNER 1 -- Conc Components MCP ----~uide 100.0% IArg°n IMinimal I 12 02-001 MOTOR OILS' Liquid 330 Minimal · Fire, Delay Hlth GAL CAS #: 64742-41-2 Trade Secret: No Form: Liquid Type: Pure Days: 365 Use: LUBRICANT -- Daily Max GALI Daily Average GAL I Annual Amount GAL 330 ~ 300.00 600.00 Storage~~Press T.Temp Location METAL CONTAINR-NONDRUMIAmDient{AmDient{NW CORNER WAREHOUSE 2 -- Conci Components { MCP ---[Guide 100.0% IMotor Oil, Petroleum Based IMinimal I 27 06/30/93 BAKERSFIELD WELL AND PUMP CO ~. 215-000-001351 Page 5 02 - Fixed Containers on Site Hazmat Inventory Detail in MCP Order 02-006 NITROGEN Gas 900 Minimal · Fire, Pressure, Immed Hlth FT3 CAS #: 7727-37-9 Trade Secret: No Form: Gas Type: Pure Days: 365 Use: WELL INJECTION OR SERVICE Daily Max FT3' Daily Average FT3 -- Annual Amount FT3 -- 900 I 500.00 --~ 900.00 Storage Press T TempI Location PORT. PRESS. CYLINDER Above /Below IO/S NE CORNER MAIN SHOP1 -- Conc Components ~ MCP ---TGuide 100.0% INitrogen ' }Low ~ 21 06/30/93 BAKERSFIELD WELL AND PUMP CO 215-000-001351 Page 6 00 - Overall Site <D> Notif./Evacuation/Medical <1> Agency Notification CALL 911 <2> Employee Notif./Evacuation SHOULD AN INCIDENT OCCUR WE HAVE A SPEAKER AND BUZZER SYSTEM TO NOTIFY OUT EMPLOYEE'S OF ANY PROBLEM. <3> Public Notif./~Evacuation NONE LISTED <4> Emergency Medical Plan VALLEY INDUSTRIAL MEDICAL GROUP 2501G STREET BAKERSFIELD, CA. 93301 (805) 327-2225 06/30/93 BAKERSFIELD WELL AND PUMP CO 215-000-001351 Page 7 00 - Overall Site <E> Mitigation/Prevent/Abatemt <1> Release Prevention MOTOR OILS ARE STORED IN DISPENSING TANKS, SERVICED AND MAINTAINED BY SUPPLIER. COMPRESSED GAS CYLINDERS ARE STORED SEPERATELY IN RACKS AND CHAINED SECURELY. <2> Release Containment <3> Clean Up <4> Other Resource Activation 06/30/93 BAKERSFIELD WELL AND PUMP CO ~- 215-000-001351 Page 8 00 - Overall Site <F> Site Emergency Factors <1> Special Hazards <2> Utility Shut-Offs A) GAS - SOUTHWEST CORNER OF MAIN SHOP (OUTSIDE) B) ELECTRICAL - SOUTHWEST CORNER OF MAIN SHOP INSIDE WALL C) WATER - NORTHWEST CORNER OF FENCE (PICCO & SON PARKING LOT) D) SPECIAL - NONE E) LOCK BOX - NO <3> Fire Protec./Avail. Water PRIVATE FIRE PROTECTION - FIRE EXTINGUISHERS PLACED THROUGHOUT OUR FACILITY. FIRE HYDRANT - NORTHEAST CORNER OF CALIFORNIA & WILLIAMS <4> Building Occupancy Level 06/30/93 BAKERSFIELD WELL AND PUMP CO :'- 215-000-001351 Page 9 00 - Overall Site <G> Training <1> Page 1 WE HAVE 20 EMPLOYEES AT THIS FACILITY WE HAVE MATERIAL SAFETY DATA SHEETS ON FILE BRIEF SUMMARY OF TRAINING: <2> Page 2 as needed <3> Held for Future Use <4> Held for Future Use BAKERSFIELD FIRE DEPARTMENT ~/.~,~,/~.~ BUREAU OF FIRE PREVENTION. Date .~.PPLICATION Application No. In conformity with provisions of pertinent ordinances, codes and/or regulations, application is made by: ' Name of Company ' / Address to display, store, install, use, operate, sell or handle materials or processes involving or creating con- ditions deemed hazardous to life or property as follows: /- RANDALL L.~BBOTT ' 2700 M Street. Suite 3~X) Agenc¥,Oirectcx Bakersfield. CA 93301 (805~'861-3502 . Telephone (805) 861-3636 ..... ' : Telecopier (805) 861-3429 STEVE Mc CALL~Y Oirec~m' RESOURCE MANAGEMENT AGENCY DEPARTMENT OF ENVIRONMENTAL HEALTH ~ERvICES PERMIT FOR PERMANENT ~ PERMIT NUMBER A 1298- OF UNDERGROUND HAZARDOUS SUBSTANCES STORAGE FACILITY FACILITY NAME/ADDRESS: OWNER(S) NAME/ADDRESS: CONTRACTOR: Bakersfield Well & Pump Elwood Champness B.S. Construction 1600 E. California Ave. 1600 E. California Ave. P.O. Box 2624 Bakersfield, CA 93301 Bakersfield, CA 93301 Lake Isabella, CA 93240 License #518528-A Phone: 805-324-6026 Phone: 619-379-4003 PERMIT FOR CLOSURE OF PERMIT EXPIRES November 20~ 1990 _.1 TANK(S) AT ABOVE APPROVAL DATE . A August ?~x1990. /Vl,. h ichheCb£iggs [1 Ha~rdous Materials S~I: ................................................................. 2 ............. POST ON PREMISES ........................................................................... CONDITIONS AS FOLLOWS:' 1. It i~ the r~mibility of the P~milt~ to obtain permit~ which may be r~uired by oth~ ~gulato~ agenci~ phor to ~nning wor~ ([~., Fire and Building Bepartment~). 2. Permitt~ mu~t no[ifg the Hazardou~ Matefial~ Managemenl Pro,am at (805) 86i-3636 two wo~ing day~ pdor 1o tank removal 'or abandonm in place to a~ange for r~uffed in~p~tion~(~). 3. Tank cl~ure activiti~ mu~ ~ per K~n County Environmental H~ith and Fire Depamment approv~ method~ a~ d~cfi~d i~ Handb~ ~ 4. It i~ th~ mmractor'~ r~pon~ibility to ~now and adh~ to all applicable la~ ~garding the handling, transportation or treatment ~ bmr. matlab. 5. The tank removal contractor mu~t have a qualified mmpany employ~ on ~ite ~u~i~ing the tank removal. The employ~ mu~t have tan~ ~m ex~ence p~or to working un~upe~i~ed. 6. R any mmracto~ other than thee li~ted on p~mit and p~it application are to ~ udlized, phor approval mu~t ~ ~anted by the ~ li~ted on the permit. Deviation from the ~ubmilted application i~ not allowed. 7. Soil Sampling: a. Tank ~e I~ than ~ ~u~ to 1,~ gallo~ - a minimum of two sampl~ must ~ retrieved from ben.th the ~nter of the ta~ at dc ~ approximately two f~t and six f~t. b. Ta~ size ~t~ than 1,0~ to 10,~0 gMlo~ - a minimum ~ four sampl~ must ~ retrieved one-third of the way iff from the e~ ~ch tank at depths ~ approximately two f~t and six f~t. c. Tank size ~t~ than 10,~ gallo~ - a minimum ~ six sampi~ must ~ retrieved one-fourth of thc way in from the ends ~ ~ch and beneath the cenler ~ ~ch tank at depths ~ approximately t~ f~t and six f~t. 8. Soil Sampling (piping a~a): A minimum ~ two sampi~ m~t be retrieved at depths ~ approximat~y two f~t and six f~t for ev~ 15 linear f~t of pipe run and unde dispen$~ ar~. . FOR PERMANENT ~ PERMIT NUMBER A 1298-1S ,DERGROUND HAZARDOUS ADDENDUM .~T~CES S3'OI~GE FACILITY Soil Sample analysis: a. All soil samples retrieved from beneath gasoline (leaded/unleaded) tanks and appurtenances must be analyzed for benzene, toluene, xyleue, and total petroleum hydrecarbous (for gasoline). b. All soil samples retrieved from beneath diesel tanks and appurtenances must be ana{yzed for total petroleum hydrocarbons (for diesel) and benzene. c. All soil samples retrieved from beneath waste oil tanks and appurtenances must be analyzed for total organic halides, lead, oil and grease. d. ~AI soil samples retrieved from beneath crude oil tau-ks and appurtenances must be analyzed for oil and grease. e. ~ soil samples retrieved from beneath tanks and appurtenances that contain unknown substances must bc analyzed for a full range of substances that may have bce-, stored within the tank. f. All soil samples retrieved from beneath tanks and appurtenances that contained furfuryi alcohol resin must be analyzed for phenols, formaldehyde and fu~uryl alcohol. 10. Thc following timetable lists pre- and post-tank removal requirements: · ' and time of clo~ure and soil sampling ' . ' .... , ' ' ' .'~ ~ = ' = ': _. -,.. Transportation and tracking forms sent to Hazardous .. :-..-.-i~.~. i?.i~ ~ :' "* No later than 5 workint days for transU°rtation and la ,...~..-.~ ,.~ ~ .:-.. Materials Management Program. All hazardous waste ~'?~ i~ :~" .:..< )-:~/ days for the trackino form after tank ..... , "' '..j!. ~ ,:'.;.-:...:'~Z"~ a, :-_> ~:~<:.Liquid shall be pumped from tank prior to purging such that less than 8 ~allons of liquid remain in tank. (csH&sC 41700) ', :: · - · Thia department is responsible for enforcing theKern County Ordinance Code, Division 8 and state regulations pertaining to underg~und storage tanks. ;,: ' .. Representatives from this department respond to job sites during tank removals to ensure that the tanks are ~afe to ~'emove/cl~e and that the overall job performance is consistent with permil requirements, applicable ia~ and safety standard~. The following guidelines are o~ered to elar~fy the interests · and expectations for th~ department. .. 'I~ ,': ',I0b site safety is one of Our primary conceras. Excavations are inherently dangerous, It is the contractor's responsibility tO know and abide by · .,CAL,-OSHA regulations. The job foreman is responsible for the crew and any subcontractors on the job. As a. general rule, workers are not . .: permitted in improperly sloped excavations or when unsafe conditions exist in the hole. Tools and equipment are to be used only for their designed : . ' function. For example, backhoe buckets are never substituted for ladders. . 2. Properly licensed contractors are assumed to understand the requirements of the permit issued. The job foreman is responsible for knowing and abiding by the conditions oi the permit. Deviation from the permit conditions may result in a stop=work order. ' 3. Individual contractors Will be held responsible for their post-removal paperwork. Tracking forms, hazardous waste manifests and analyses documentation are necessary for each site in order to cluse a case file or move it into mitigation. When contractors do not follow tlu'ough on necessary paperwork, an unmanageable backlog of incomplete cases results, lg this continues, processing time for completing new clo~ures wi0 increase. Accepted By: ~- OWNER OR AGENT DATE MD:ch driggs \ 1298- IS.pta ( type or ~rin~ name ) RECEIVED FEI] 9 19a9 Do hereby c~rt~ ~-- ' ' ~ _z~ that I have revzewe~ the attached Hazardous Materials business plan (name of business) and that it along with the attached additions or corrections constitute a comBlete and correct Business Plan for my facility. BUSINESS NAME ' ~ COMPANY INC ID ~1S-000-00t3SI LOCATION 1600 E CALIFORNIA AV HIGH HAZARD RATING 3 1, OVERVIEW LAST CHANGE 10/t9/88 BY VAL JURIS COOE 21S-~ JURIS BAKERSFIELD STATION:02 HAP PAGE 103 GRID ~3A FACILITY UNITS I HAZARD RATING RESPONSE SUMMARY Z~ SEC 4) SEVERAL OF OUR EMPLOYEE'S HAVE HAO AN ENVIRONMENTAL TRAINING COURSE. THIS COURSE HEETS THE Z9 CFR 1910,128 REQUIREMENTS, ALSO WE HAVE ON HAND, BAGS OF ABSONITE AND SS GALLON H 17 DRUMS. EMERGENCY CONTACTS ~A SEC JOHN WOODARD - 3Z4-~0~ - JOE LOPEZ - 3Z4-GOZG - 399'..-80Z5 UTILITY SHUTOFFS ZA SEC 3) A) G~S - SW CORNER OF HAIN SHOP (OUTSIDE), B) ELECTRICAL - SW CORNER OF HAIN SHOP INSIDE WALL. C) WATER - NW CORNER OF FENCE (PICCO & SON PARKING LOT). O) sPEcIAL - NONE E) LOCKBOX - NO NOTIFICATION / PUBLIC EVACUATION LAST CHANGE / / BY < NO INFORMBTION RECORDED FOR THIS SECTION > PAGE I lZ/Z3/88 11:13 MATERIAL SAFETY DATA SYSTEMS, INC. (805) G48-8800 BUSINESS NAME ' . .~ ._ COMPANY INC LOCATION IB~ E C~LIFORNI~ A~ HIGH HAZARD RATING ~. H~Z MAT TRAINING SUMM~RY L~ST CFIBNGE / / BY < NO INFORMATION RECORDED FOR THIS SECTION > LOCAl_ EMERGENCY MEDICAL ASSISTBNCE LAST CHANGE 10/19/SA'BY VAL 2A SEC b TUtm~ ~ .5.~,, ,-,.~., PAGE Z lZ/Z3/88 MATERIAL SAFETY DATA SYSTEMS, INC, (805) BUSINESS NAME COMPANY INC ID NU 21S-000-0013S1 LOC~TION 1600 E CRLIFORNI~ ~V HIGH H~ZARD RATING FACILITY UNIT 81 A. OVERALl, HAZARDOUS M~TERIALS INVENTORY L.~ST CHRNGE ~SXlgXS~ BY VAL ID TYPE NAME MAX AMT UNIT H~Z~RD LOC4TION CONTAINMENT USE ! PURE MOTOR OILS 3~ GAL, UNKNOWN NW CORNER ~RREHOUSE Z MET4L CONTAINERS LUBRICANT ID PERCENT COMPONENTS H~Z~RD LIST ZBSB.~ ~08.8 MOTOR [)IL UNKNOWN 2 PURE RNTIFREEZ~ ~ GRL UNKNOWN NE CORNER ~AREHOUSE Z DRUMS OR B~RRELS MET.. COOLANT ID PERCENT COMPONENTS H4Z~RD LIST ZB~Z~ ~C~0.0 ETHYLENE GLYCOL UNKNOWN 3 U~STE ,~ASTE OIL o¢~ 508 G~L UN~NO~N OUTSIDE~._ ~RLI_ ~ 4BOVE GROUND TRNKS ID PERCENT COMPONENTS H4Z~RD LIST' ~SB8.08 100.8 WASTE OIL UNKNOWN 4 PURE 4CETYLENE 8(D8 FT3 EXTREME O/S NE CORNER M~IN SHOPi pORTaBLE PRE~S. CYL. ~ELDING/SOLDERING ID PERCENT COMPONENTS H4Z~RD LIST tZ4~,00 100~0 4CETYL. ENE EXTREME ~ PURE OXYGEN BO~ FT3 HIGH O/S NE CORNER MHIN ~HOP1 PORTABLE PRESS. CYL, OTHER ID PERCENT COMPONENTS H~Z~RD LIST Z3SB,~ 1~.~ OXYGEN, COMPRESSED HIGH B PURE NITROGEN B~ FT3 MODERATE O/S NE CORNER M~IN SHOPI.PORTRBLE PRESS~ CYL, ~ELL. INJECTION ID PERCENT COMPONENTS H~Z~RD LIST Z324,~ 1~,0 NITROGEN MODERATE ? PURE ~RGON 3~B FT3 NONE t/S SHOP ND CORNER t PORTABLE PRESS. CYL, ~ELDING/GOLDERING ID PERCENT COMPONENTS H~Z~RD LIST 13GS.~ I~,~ ~RGON NONE PAGE M~TERI~L S~FETY D~TR SYSTEMS, iNC, (885) G48-G880 I~A~P.~I.~ w~ ~ ~u,,,,.,p BUSINESS NAME-]IIIII~ COMPANY INC !O Z15-000-0~1351 LOCATION 16OO E CRLIFORNI~ AV HIGH H~ZRRD RATING B. FIRE PROTECTION / g~TER SUPPLIES L~IST CHANGE 10/19/88 BY gAL SEC 4) FIRE EXTINGUISHERS PLACED THROUGHOUT OUR FACILITY. SEC S) NE CORNER oF C~L. IF'ORNI~ AV ~N[) WILLI~MS EMPLOYEE NOTIFICATION / EVACUATION LBS'F CHANGE 10/19/B8 BY V~L SEC Z) SHOULD AN INCIDENT OCCUR WE HAVE A SPEAKER AND BUZZER SYSTEM TO NOTIFY OUR EMPLOYEE'S OF ANY PROBLEM, PAGE 4 12/2~/88 11:1~ MAI'ERIRL SAFETY O~TA SYSTEMS, INC, (80S) 848-B808 SEC 1) MOTOR OILS ~]RE STORED IH DISPENSING T~NI<S. SERVICED FIND M~INTRINED BY SUPPLIER. COMPRESSED Gt~S CYLINDERS ORE STORED SERER~II'ELY IH R~CKS f,~NO CHAINED SECURELY. P~GE S 12/Z3/B8 11:13 MRTERIRL SRFETY DRTR SYSTEMS, INC. (80S) G48-G800 CITY of BAKERSFIELD NON--TRADE SECRETS , BUSINESS NAME: BAKERSFIELD WELL & PUMP GO.OwNER NAME: NAME OF TI~ PACIL cr~. Z:P:~ B~ERSFIELD 93307 C:~, ZIP: ~O OUX ~ B~S~ ..~..t P I 349 } 349 I, 349 . t~t~. 365t o4 1.2 I 6 I~g. Iz/s Sno?~z ~.w.co~%: ~cou ~zoo6 "~'~ P I 800 I 500 INA IF+t....!~}{,0 2 I ~ 42 Io/s N.E.COR~ER sHoP~tl';iO0: ACE~ENTE ~1001 r~l ~ ~ltb h~ C.A.S, ~ 74-86-2 ~t 11 ~ & C,A.S. W N/A 3 .... i ......... m~ I ~ Mltb ~ C.A.S. ~ 7727-37-9 ~ t{ ~ a C.A.S. ~ ~ ~ s~ JO~ WOOD~ P~SID~T (805)324-6026 ~OE LOPEZ SUPERVISOR (805) J0~ W00D~ P~SID~  ................ ~te CITY of BAKERSFIELD , p~ .~_ of ~... C:TY, ZIP: B~ERSFIELDa 93307 cz~, ZIP: DUN ,..~L? 1'5'330 I 300 I 600 ¢~.1,365 I x3 I ~ 14 I 26 I".W.CO~ER W~EHOUS. E~2 . "0~03 O~3~.PE!ROLE~ ~RO C~O,,, of ~ ~lth 15% t~cAS68~49~2-3 ............ - d ~ ~lch ..... ~t ~3 ~&C.A.S. ~ ~Y ~T~TS It JO~ WOOD~ PRESIDENT ~05) 324-6026 . JOE LOPEZ ~tiftcott~ (Read ~d sl~ after c~plotln~ 41] sectJon~) 2130 "G" STREET ERSF ELO. CA (805) 326-39V9 US INESS N~E 1. To avoid further action, return th~s foum b~ 2. TYPE/~R[ST ASS~ERS I~ ENGLISH. 3. Answer the questions belo~ for the business as a ~hole. 4. Be as brief and concise as possible. A. BUSINESS ~A~E: LAY~E-~ESTE~ COHP~Y, B. LOCATIO~ / STREET ADBRESS: 1600 E. California CITY: Bakersfield ~IP: 93307 BUS.PHONE: (805) 324-6026 SECTION 2: EMERGENCY NOTIFICATIONS In case of an emergency involving the release or threatened release of a hazardous material, call 911 and 1-800-852-75~0 or 1-916-427-4341. This wilt notify your local fire department and the State Office of Emergency Services as req, ired by law. EMPLOYEES TO NOTIFY IN CASE OF EMERGENCY: NAME AND TITLE DURING BUS. HRS, AFTER BUS. HRS. A. John Woodard Ph# (805)- 324-6026 Ph~ (805) B. Joe Lopez Ph~ (805) 324-6026 Ph= (805] 3qq-8075 SECTION 3: LOCATION OF UTILITY SHUT-OFFS FOR BUSINESS AS A WHOLE A. NAT. GAS/PROPANE: S.W. Corner of Main. Shop (Outside) B. ELECTRICAL: S.W. Corner of Main Shop Inside Wall C. WATER: N.W. Corner of Fence (Picco & Son Parking Lot) D. SPECIAL: E. LOCK BOX: YES /~IF YES, LOCATION: IF YES, DOES tT CONTAIN SITE PLANS? YES / NO MSDSS? YES ./ NO FLOOR PLANS? YES / NO KEYS? YES / NO - 2A - SECTION 4: PRIVATE RESPONSE TEAM FOR BUSINESS AS A WHOLE Several of our employee's have had an'Environmental Training Course. This course meets the 29 CFR 1910.120 requirements. Also we have on hand, bags of absonite and:.~5 '.g~lio~' H 17 Drums. SECTION 5: LOCAL EMERGENCY MEDICAL ASSISTANCE FOR YOb~ BUSINESS AS A WHOLE Young Wu Park M.D. 2323 16th Street, Suite 200 Bakersfield, CA 93301 (805) 327-5667 SECTION 6: EMPLOYEE TRAINING EMPLOYERS ARE REQUIRED TO HAVE A PROGRAM WHICH PROVIDES EMPLOYEES WITH INITIAL AND REFRESHER TRAINING IN THE FOLLOWING AREAS. CIRCLE YES OR NO INITIAL REFRESHER A. METHODS FOR SAFE HANDLING OF HAZARDOUS .MATERIALS ' ' ~ NO ~NO B. PROCEDURES FOR COORDINATING ACTIVITIES WITH RESPONSE AGENCIES: .......................... YES YfJ_~ YES NO C. PROPER USE OF SAFETY EQUIPMENT: .................. Y~ NO Y~ NO D. EMERGENCY EVACUATION PROCEDURES: ................. -~NO YES NO E. DO YOU MAINTAIN EMPLOYEE TRAINING RECORDS: ....... NO ~ NO SECTION 7: HAZARDOUS MATERIAL CIRCLE~~.NO - NOt~ DOES YOUR BUSINESS HANDLE HAZARDOUS ~TERIAL IN QUANTITIES LESS THAN 500~.POU.!LDS OF A SOLID, $5 GALLONS OF A LIQUID, OR fi00 CUBIC FEET OF A COMPRESSED GAS: ...... <YES~ NO I unders~'~nd-that thl~f'i-~or~tion will. be used to fulfill my firm's obligations under the new V~lifornia Health and-Safety code on Hazardous Materials (Div. riO Chapter 6.95 Sec. 25500 Et Al.) and that inaccurate information constitutes perjury. - 2B - BAKERSFIELD CITY FiRE DEPART>~NT 2130 "G" STREET BAKERSFIELD, CA 93301 OFFiCiAL USE ONLY ID# BUSINESS NAME: BUSI NESS PLAN SINGLE FACILITY UNIT FORM SA INSTRUCTIONS I. To avoid further action, this form must be retuened by: 2. TYPE/PRINT YOUR ANSWERS IN ENGLISH. 3. Answer the questions below for THE FACILITY UNIT LISTED BELOW 4. Be as ~RiEF a~d CONCISE as possible.' FACILII"[ UNIT~ FACILITY 5~NIT NP.WE: LAYNE-WESTERN COMPANY, INC. SECTION 1: .~ITIGAT!ON, PREVENTION, ABATEMEN-r PROCEDB~RES Motor Oils are stored 'in Dispensing tanks, serviced and maintained by Supplier. Compressed Gas Cylinders are stored seperately in racks .and chained securely. SECTION 2: NOTiFICATiON AN~ EVACUATION PROCED~.~ES AT THIS 5%'iT OXLY Should an incident occur we have a speaker, and b~zzer system to notify our employee's of any problem. - 3A - SECTION $: HAZARDOUS MATERIALS FOR THIS b~IT ONLY A. Does this Facility Unit contain Hazardous Materials? ...... ~YES~ NO If YES, see B. If NO, continue with SECTION 4. B. Are any of the hazardous materials a bona fide Trade Secret YES~NO~ If No, complete'a separate hazardous materials inventory form marked: NON-TRADE SECRETS ONLy (white form ~4A-1) If Yes, complete a hazardous materials inventory form marked: TRADE SECRETS ONLY (yellow form :4A-Z) in addition to the non-trade secret form. List only the trade secrets on form 4A-2. SECTION ~: PRIVATE FIRE PROTECTION Fire Extinguishers placed throughout our facility. SECTION $: LOCATION OF WATER SUPPLY FOR USE BY EMERGENCY RESPONDERS N.E. Corner of California Avenue and Williams SECTION S: £OCATION OF UTILITY SHb~-OFFS AT THIS UNIT ONLY. A. XAT. GAS/PROPANE~ S.W. Corner of Main Shop (Oultside Wall) B. ELECTRICAL: ' S.W. Corner of Main Shop (Inside Wall) C. WATER: .- N.W. Corner of Yard Fence (Picco & Son Parking Lot) SPECIAL: E. LOCK BOX: YES '~!F YES, LOCATION: tF YES, SITE PLANS? YES / NO MSDSs? YES ." NO FLOOR PLAXS? YES / NO KEYS? YES / NO - 3B - BAKERSFIELD CITY FIRE DEPARTMENT I.D. # FORM 4A-1 Page ,. 1 o~f _1 NON--TRADE SECRETS HAZARDOUS MATERI ALS INVENTORY BUSINESS NAME: LAYNE-WESTERN COMPANY, INC. OWNER NAME: FACILITY UNIT #:__ ADDRESS: ~ 1600 East California Avenue ADDRESS: FACILITY UNIT NAME: CITY, ZIP: Bakersfield. CA 93307 CITY,ZIP: P-HONE #: 324-6026 ~ PHONE #: ~OFFICIAL USE' CFIRS CODE 0 N,,L,Y 1 2 3 4 5 6 7 8 9 10 TYPE MAX ANNUAl., CONT USE LOCATION IN THIS % BY HAZARD D.O.T CODE AMOUNT AMOUNT UN. IT CODE CODE FACILITY UNIT WT, CHEMIqAL OR COMMON NAME COD,E GUIDE I) N.W. Corner of P 330 600 Gal 13 26 Warehouse #2 100 Motor Oils (Petroleum Hydro Carbon) CMLO None ~" N.E. Corner of ~O ~.~ P 55 110 Gal 06 09 Warehouse #2 100 A~-Freeze (Ethv]ene Glvcon~ PSNB None Outside East Wall of ~)W-221 500 1000 Gal 02~ 40 Mai~ Shoo {/1 100 Waste Oil NA 1270 CMI,O N/A cu ft Outside N.E. Corner of ~ / P 800 N/A F+3 04 42 Main Shod ~] 100 Angry] mn~ Un' ] 0~1 V].CR N/A 99 Outside N.E. Corner of 0XID ~_ P 600 N/A F+3 04 :uttin Main Shop #1 100 Oxygen Un 1072 ~ NFLG N/A Outside N.E. Corner of P 900 N/A F+3 04 43 Main Shop #1 100 Nitromen U~ 1066 NFG N/A Inside Shop N.W. Corner P 349 349 F+3 04 42 f/1 100 1006 N/A Argon Un NFG NAME: Joe--A Lopez TITLE: Service Supt. S GNATDRE: C~%~_ Q~ ~_~. DATE: ,~$MERGENCY~ONTACT: Joe Lopez TITLE: Service Supt. ~HONE #~U~ ~URS: 324-6026 AFTER BUS HRS: 399-8025 EMERGENCY CONTACT: John B Woodard TITLE: District Manager PHONE # BUS HOURS: 324-6026 ,~"-PRINCIPAL BUSINESS ACTIVITY: Water Supply Contractor's AFTER BUS HRS: 366-0291 3/16" = 10" LAYNE-WESTERN COMPANY, INC. 8-29-88 N/A CHEC;,.*, :~:'~i: S :~ ~.~,..~ ....... _., ...... SEE ATTACHED MAP