Loading...
HomeMy WebLinkAboutMITIGATION-! .! FINAL CLOSURE REPORT FOR PERMIT #BR-0320 Site: SBC S/I098 Formerly Pacific B,, ell 3221 South '~I St Baker~eld C,4 93304-5649 Prepare~ SBC Communications Inc. SBC Services Inc. zdttn: James Stehr P. O. Box 5095 Room E3000S San Ramon, CA 94583-0995 May 21, 2004 PreParedBy"/ ~.~///;'"~ -~~0 Se~ed Morte a~lo~avavi. Ph.D.C~i~':'~i~_ Pdndpal Hydrogeologist/Engineer ~~~'~'~/ "x~ '" "'~ '-',Inc. CHG. No. 5!6 ~ Consulting Engineers ~ Geologists unvm. ~ drologue, com 2793 East Foothill Boulevard · Pasadena, CA 91107 · Phone (626)585-9696 · Fax (626)585-0046 I I I I I I I I I I I I I I I I I I TABLE OF CONTENTS 1.0 INTRODUCTION ...................................................................................................................... 1 2.0 FIELD WORK ........................................................................................................................... 1 2.1 UST Cleaning/Removal ........................................................................................................... 1 2.2 Soil Sampling Following UST Removal ................................................................................. 2 2.3 Analytical Testing .................................................................................................................... 3 3.0 DISCUSSION AND CONCLUSIONS ...................................................................................... 4 4.0 LIMITATIONS .......................................................................................................................... 4 5.0 PROOF OF SERVICE AFFIDAVIT ......................................................................................... 5 FIGURES: Figure 1: Figure 2: Figure 3: Site Location Map Site Plan UST Removal Photographs APPENDICES: Appendix A: Appendix B: Appendix C: Appendix D: Appendix E: Chain of Custody Record Forms and Laboratory Reports Rinsate Disposal Manifest and Other Certification UST Destruction & Certification UST Removal Permits Soil Sampling Protocol hydrologue, Inc. Final Closure Report SBC SAo98 3221 S "H" St Bakersfield CA 933o4-5649 Project No. 2762-00 Permit #BR-o32o I I I I I I I I I I I I I I I I I 1.0 INTRODUCTION This report presents the results of Soil sampling and analytical testing associated with the removal of one 5,000-gallon double-wall steel diesel Underground Storage Tanks (UST) and associated piping located at the SBC SA098 facility (formerly Pacific Bell) at 3221 S "H" St Bakersfield CA 93304-5649 ("Site") (Figure 1). hydrologue Inc. (HI) was retained by SBC, the property owner, to: 1) collect soil samples following the UST removal from beneath the former location of the USTs, fuel dispenser and product piping (if any); 2) supervise any additional excavation work related to defining, removing, and confirmation of contaminated soil removal; and 3) prepare a report describing the UST removal and any additional activities related to the UST removal. The protocols and procedures for removal of the UST are in conformance with those of the Bakersfield Fire Dept. Environmental Services. All work was performed under the direct supervision of a HI California Certified Hydrogeologist/ Registered Geologist. 2.0 FIELD WORK 2.1 UST Cleaning/Removal SBC provided the required permits for the removal of the UST (Appendix A). HI prepared a Health and Safety Plan for UST removal activities, which was followed and kept on-site during all field activities. SBC retained a separate contractor to excavate, remove and dispose of the UST. On May 11, 2004, Oil Conservation Services (DTSC ID # CAD 980 673 842) was contracted to remove the rinsate and clean the UST. The UST was checked for flammability and oxygen content and the Lower Explosive Level (LEL) and oxygen percentage inside the UST was monitored by the rinsing sub-contractor. Air purging of the UST was continued until the readings reached the regulatory LEL levels. The UST interior was then water blasted using a mixture of water and detergent under a pressure of 10,000 psi. Loose scale, sludge and rinsate were removed by a rinsing sub-contractor vacuum truck. When the sludge and other debris were removed and the LEL reading reached regulatory levels, the washing ceased. The UST was degassed if necessary as per local air quality rules and regulations. Dry ice was then added to the UST which was witnessed by the inspector(s). The rinsate and sludge generated from UST cleaning activity was manifested (Uniform Hazardous Waste Manifests [Appendix BI) and transported to a full approved and permitted Treatment, Storage and Disposal (TSD) facility by a licensed hazardous waste transporter. A copy of the manifest was provided to the inspector(s) witnessing the UST removal. 1 hydrologue, inc. I I Final Closure Report SBC SAo98 3221 S "H" St Bakersfield CA 933o4-5649 Project No. 2762-oo Permit #BR-o32o The UST was removed on May 11, 2004. Upon removal, the UST was visually inspected and I I I I I I I I I I I I I I I I found to be in a good condition with no apparent holes or cracks. The UST contained the Underwriters Laboratory, Inc. UST inspection label (27952) for hazardous fluids storage. The UST was transported for destruction and scrap metal recycling to Oil Conservation Service in Fresno and then on to Livi's Iron and Metal in Fresno, California (Appendix C). Inspector Mr. Steve Underwood was present on-site to witness UST removal activities. During UST removal activities, HI monitored vapor concentrations around the excavation using a handheld Photovac Microtip Photoionizer Detector (PID) Model MP-1000 calibrated against an Isobutylene gas standard. Vapors ranging up to 0.0 parts per million by volume (ppmv) were detected. Approximately 19 feet of flexible double-walled product piping was also removed (Figure 2). The product Piping was visually inspected and determined to be in a good condition with no apparent holes or cracks. The soil exposed during product piping removal did not show any olfactory evidence of hydrocarbon contamination. 2.2 Soil Sampling Following UST Removal All soil sampling was conducted under the direct supervision, direction and approval of Inspector- Mr. Steve Underwood. The inspector mandated that below UST sampling was not necessary. Only one soil sample was collected undisturbed from the piping excavation. Soil samples P 1 ~5'was collected approximately 2 feet below the product piping invert along the former product piping associated with the UST Please see Appendix E for sampling protocol No groundwater was encountered during UST removal and soil sampling activities. All backfilling was completed directly by SBC without HI involvement. hydrologue, Inc. I I Final Closure Report SBC SAo98 3221 S "H" St Bakersfield CA 93304-5649 Project No. 2762-oo Permit #BR-o32o I I I I I I 2.3 Analytical Testing The County Inspector directed that the soil sample collected from below the piping be analytically tested for Total PetroleUm Hydrocarbons with a Diesel Standard using Modified EPA Method 8015 (TPH-D); and for Benzene, Toluene, Ethylbenzene and total Xylenes and MTBE using EPA Method 8021B The soil samPles were analytically tested offsite by Associated Laboratory (AL). AL is State certified for hazardous waste testing (Certification No. 1338) using a 24-hour turn-around-time. TABLE 1 Analytical Testing Results for Soil Samples parts per million (ppm) TEPH Benzene Ethyl Methyl t - Toluene Xylene Diesel benzene butyl ether (total) (m~Kg) (mg/Kg) (mg/K~) (mg/Kg) (mg/Kg) (mg/rg) P 1 ~5' < 1.0 <0.005 <0.005 <0.035 <0.005 <0.015 I I I I I I I I I I I hydrologue, Inc. I I Final Closure Report SBC SAO98 3221'S "H" St Bakersfield CA 933o4-5649 Project No. 2762-oo Permit #BR-o32o I iI I I I I I I I I I I I I I I I. 3.0 DISCUSSION AND CONCLUSIONS Based on the data contained in this report, the following are concluded: · Field observations, and air monitoring indicated that there was no unauthorized release from the UST · The CUPA inspector based on field observations mandated that no sampling was necessary below the former UST · No TPH-D, BTEX or MTBE were detected in the soil samples obtained from beneath the product piping. Based on the information contained herein, on behalf of SBC Communications (Former Pacific Bell), HI hereby respectfully requests that site closure be granted by the County for the UST and product piping removal activities. 4.0 LIMITATIONS Our professional services have been performed using that degree of care and skill ordinarily exercised, under similar circumstances, by reputable environmental consultants practicing in this or similar localities. The findings and conclusions presented herein are based primarily upon the analyses of test results from the soil and/or water and/or air samples during this study. This report has been prepared exclusively for SBC Communications (CLIENT) for the subject site at a specific point in time, and hence it DOES NOT contain sufficient information for other parties or other uses. No third party shall have the right to rely on HI's opinions rendered in connection with this report without HI's written consent. This report shall not create an5 rights or benefits to parties other than CLIENT and HI. The conclusions and recommendations included in this report are based on information contained or referenced herein, and our best judgment. No other warranty, expressed or implied, is made as to the professional advice contained in this report. No right or interest in the contract associated with this report may be assigned by either HI or CLIENT without the written permission of the other party, and any attempted assignment shall be wholly void and totally ineffective for all purposes. No delegation of any duty owed by either HI or CLIENT may be made without the written permission of the other party. This report is prepared subject to the terms and conditions in the contract related to this report and which was expressly negotiated, agreed to and acknowledged by CLIENT. 4 hydrologue, Inc. I I Final Closure Report SBC SAo98 3221 S "H" St Bakersfield CA 93304-5649 5.0 PROOF OF SERVICE AFFIDAVIT Project No. 2762-00 Permit #BR-0320 I I I I I I I I I I I I I I I I I I declare that I served copies of the above referenced FINAL CLOSURE REPORT FOR PERMIT #BR-0320 dated May 21, 2004 by First Class U.S. Mail postage prepaid in a sealed envelope to each of the parties at the address shown below. The mailing and this certification occurred at the place and date shown below. STEVE UNDERWOOD Bakersfield Fire Dept. Environmental Services 900 Truxtun Ave Ste. 210 Bakersfield, CA 9330 ANDREW SOUTER SBC Corporate Real Estate 3707 Kings Way, Room B15 Sacramento, CA 95851 I declare under penalty of perjury that the foregoing is true and correct. Date of Mailin/g;dXd/¢~/21, By: .. 2004 Place of Mailing: Pasadena, California , MARIA BOON, Clerk at Hydrologue Inc. One original copy was also sent via Airborne Express to SBC. \\TRITON\projects\REPORTS\SBC\UST Removal\Kern\HStreet\Closure Report.doc 5 hydrologue, Inc. Printed t?em TOPO! ~2001 Naiional Oeo~aphic Hold~g~ (www.topo.¢~m) ~,~ SITE ~ '~ LOCATION ~ R0^D ~- ~ 3221 S H ST WHITF L^NE SiTE LOCATION MAP PROJECT 2762-00 hydrologue, Inc. Consulting Engineers & Geologists I I I I I I I I' I I I I I I I I I I I~ N 89° 49' 30"W ~ CONCRETE BLDG o~ ~ ~ ENGIN~ ~ ROOM N~ SCALE ~ 0 20 feet ~ ~ ~ ~ 3221 S HST ~i/ BAKERSFIELD CA 93304-5649 ~TITLE UST EXCAVATION - SAMPLING LOCATIONS p~ ~ SOIL SAMPLE FROM BELOW FORMER IPROUECT PRODUCT P~P~Ne ~ / 2762-00 2 / I ~ hydrologue, Inc. ASSOCL4 TED LABORATORIES · - Orange, California 92868 - 714/771-6900 y, (6979) 2793 East Foothill Blvd. Pasadena, CA 9l 107-3400 #2762 SBC SA098 H ST 3221 S. "H" St., Bakersfield FAX 714/538-1209 LAB REQUEST 129179 REPORTED 05/17/2004 RECEIVED 05/11/2004 This laboratory request covers the fbllowing listed samples which were analyzed fi)r the parameters indicated on the attached Analytical Result Report. All analyses were conducted using the appropriate methods as indicated on the report. This cover letter is an integral part of the final report. Order No. Client Sample Identification 52OO6O P 1 ~5' 520061 Laboratory Method Blank Thank you tbr the opportunity to be of service to your company, Please t~el free to call it'there are any questions regarding this report or if we can be of further service, . NOTE: Unless notified in ~vrit#~g, all samples will be discarded by appropriate disposal protocol 30 days from dale reported TESTI:\:G & CONSULTING The reports ot'~he Associated Laboratories m confidential property ot'our clients md Chemical ma>' not be reproduced or usecl tbr pubh~:atmn m part or tn ti. lil w~thout our written ,~licrobio/ogica[ penuission. This is tbr the mutual protection of the public, our clients, and ourselves. £nvironntentct/ Lab request 129179 cover, page 1 ot'l i~ate Sampled: 05/11/2004 ' . . · I ,Analyte , Result DF DLR ,Units Date/Analyst 8015 TEPH Diesel ~;&-i ............................................................... F~I .......... i' ........ ~ Surrogates Units Control Limit. _ "~'~a ................................................................... . ....................................... ~- .................... ~ ............. ~ ........ ~:~'~ ....... ~ ........ ~'~'~'~;.o~ .... ~,'" I .... ...~...;.~.~;...g:t.;~;~;.;~;~.~*...n.;~.;;..L~:.;:~:;:.;~;.:;.;.....:....3.7..;.:.;;. :"..'.:: ;";7.2.;::2.Zi;.'.;.:.;/;.;;L.7...'..;..;.~i...;7:''-'~ ........ ;7;o/;o-f~;.c::m-.~.~...~:.~:-~ 05./~.4/04. LT , Metaylt5 bUg!_.8.~.~.sr ............................................................... I ............................. ~1 ............. t ........ ,?.:..035 ..... m,.g(K.g ..... 05.(14{04 LT Xylene (total) ~ 1 0 015 rog/Kg 05/14/04 LT Surrogates Units Co rrol Limits LR = Detection limit tbr repo~g pu~oses, ~ = Not Detected below indicated detection lh~it, DF = Dilution Factor  Analytical .Results Report Control Limits Control Limits Lab Request 129179 results, page l ot'2 ~)rder#: I 52~0611 Matrix: SOLID ,ate Sampled: i'ime Sampled: Sampled By: Client: Hydrologu¢, Inc. Client ~ample ID: Laboratory Method Blank I Analyte Result DF DLR Units 8015 TEPIt Diesel Date/Analyst iSurrogates Units Control Limits -- .,,ii 'B.~5~;fi.';,71'.i' '....,". "f ,~i ..'.fi', i',i'i ........ '...i .... '.'; .... i.'i.'.,..i,.]i,} ...... '..i,'.,.'.'.'NB[ "'i...:! .......... °..7°..°.5.,..'i?g.'!~f' "'~J~214!0.'~'f'L'r I Ethyl benzene ND I 0.005 mg/Kg 05/14/04 LT -- '.""f~!i{i'2.1~!!!~'!i.~'~i!!ilf.il.7'f.i'.'ii'i '.71.iii..i'.i.ii,'i.:.....i.'..i.'...i ...... i.ii.'.i"ii'i.ii.ii i17.,'.i'.i .i.'i.ii .i'fi'i"'-'~[ ...... , ."i i ,.?'~.3'5 ' rog/Kg.,. ". ~15/!~4¢~4... LT' ma 'Toluene [ ND{ I 0.005 mg/Kg 05/14/04 LT ILK = Detection linait tbr reporting purposes, ND = Not Detected below indicated detection limit, DF = Dilution Factor ,~//'~A ' QC Sample: Matrix: Extraction Method: Prep. Date: Analysis Date: ID#'s in Batch: Reporting Units = ASSOCIATED LABORATORIES LCS REPORT FORM LCS/LCSD SOLID 3545 05/13/04 05/13/04 LR 129252,129179 mg/Kg pREpARATION BLANK / LAB CONTROL SAMPLE RESULTS PREP BLK Value Result [ True [ %Rec [ L.Limit [ H.Limit Test Method LCS ND 2 ! 25 84 70% 130% DIESEL 8015D LCSD ND 23 25 92 70% 130% LCS Result = Lab Control Sample Result T~e = Trite Value qf LCS L. Limit / H. Limit= LC$ Control Limits SURROGATE RECOVERY Sample No. O-Terphenyl QC Limit 55-200 Method Blank 115 LCS 154 LCSD 149 I I $118/2004 8015d Icsd 0513s I I I I I I I ASSOCIATED LABORATORIES LCS REPORT FORM QC Sample: LCS / LCSD Matrix: SOLID Prep. Date: 05/14/04 Analysis Date: 05/14/04 LAB ID#'s in Batch: LR 129179 REPORTING UNITS = mg/Kg PREPARATION BLANK / LAB CONTROL SAMPLE RESULTS PREP. BLK LCS [ LCSD Method Value Result I TRVE I %Ree Result I %Ree Benzene 8021 ND 0.016 0.02 80 0.016 80 Toluene 8021 ND · 0.02 [ 0.02 105 0.021 105 E!,hylbenzene 8021 ND 0.021 0.02 105 0.021 105 Xylenes 8021 ND 0.061 0.06 102 0.061 102 I I I I I LC$ = Lab Control Sample Res. It TRUE = Tr,te Yalue qf LCS L.LIMIT / H. LIMIT= LCS Control Limits SURROGATE RECOVERY Sample No. AAA-TFT QC Limit 55-200 Method Blank 63 LCS 93 LCSD 91 AAA- TFT = a,a.a- Difl'torotohtene 5/18/2004 8021 btex lcsd 0514s L.Llmlt ] H. Llmit ] 80% 120% I A~SOCIATED I,A-BORATOPJES 806 North .Batavia. Orange, California 92868-1225- 714/771-6900 I I I I I I I I I I i;.,~X n 4/sss-~209 Cooler Receipt Form Client: .., Project: Date Cooler R. eceived:, ~-/(! Date Cooler Opened: Was cooler sCanned for presence"of radioactivity ? ,If yes ~as,mdioactivi,ty results above 25 cpm ? ,Was a shippeffs packing .slip attached to the.cooler ? I,f the cooler had custody seal(s), were thy signed and intact Was the cooler packed with: Ice_ x 'Ice Packs. ' S~'rofo~ttn, , .Paper. Cooler Temperature: ~', 'l ~ C/ * Bt~bble wrap. _ None. O~er . ~oflqa *cooler needs to be re. ceived ~ 4°C ~th an acceptable., range 'of2o. 6 °C If sltt~ples wire., hand delivered do they meet the temp. criteria, which should be ~ acceptable range of 2°. 6 °C ? . . If no explain: .were all samples seal,ed ~n plastic .bags ? Did all samples arrive intact ? I£no, indicate below. Were.all samples labeled, correct{y '~ OD'.s Dates, Times) if no, indicate below. Can'the tests required be'ran with the provided containers, If no indicate b~low, "Was.sufficient sample volUme ~ent for all containers ? · Were any.¥0A vials received. With head space. ? Was the correct preservatives used ? If no, see the pH.log for a list bf Samples containers regar~ling pH . Any other important, information: ' ~0 Yes/No~a I I Recefving Department: Date: CHAIN-OF-CUSTODY RECORD FORM ue Inc. ~..,..o,,.~,,,,,E :REGULAR SAMPLE ID DAlE 05111/04 SBC SA098 H ST ADOaESS 3221 SOUTH "H" ST BAKERSFIELD CA 93304-5649 CHRIS D'SA DESCRIP110N 2 feet below product Piping hydrologue Inc', Consulting Engineers eY' Geologists Mk3HOD5 I 1 PAGE OF SPECIAL HANDU~ ONE BRASS SLEEVE EMAIL RESULTS TO chris~hydrologue_com ALSO-FAX PmNIED NNV~ RBJNQUISHED BY PI~NIED NAI~ RTIN1ED NN~ ~ CCXV4~ANY SIGNAliZE ~._.~NAIURE ~ ASSOCIA, ~-u 714771-6900 KRISTEN, DEBRA, OR REMARKS State of California--Environmental Protection Agency >tm Approved OMB No. 2050-0039 Expires 9-30-99) See Instructions on back of ,"~qe 6. Department of Toxic Substancee Control r~rint or type. Form designed For use oh e ire (12-pffch, tiler. Sacramento, California UNIFORM HAZARDOUS 1. Generator's US EPA ID No. Manlfeat Document No. 2. Page 1 Information in the shaded areas is not required by Federal Iow. " 2'" ~ ~ '"~.~ !" ~i~ ""I. 3. Generator'sm,.,r ' Name and Mailing Address A. State ~onifest Document Number '~ 3 7 ~:' '~ ~. Transporter 1 Company Name 6, US EPA ID Number C, State Tran~port~r's ID [Reser~ed.~ '- ,'.. 7. Transporter 2 Company Name 8. US EPA ID Number E. S~ate Transporter's ID [Reserved.] 9. :Designated ~acil ~ Na~e and:$~e Addre~ . 10. US EPA ID Number G. State Facili~'s ID ...... .. ~_ ,,,~., ~ .:: ..... , .Lief/,' ~. ~o¢,i~'.,ho,... I' "1~'1~T'~I'' '1''> lul~.>l:..,i, (2.{~>>)~s"' '~, 12. Containers 13. Total 14. Unit 11. US DOT Description (including Pro,er Shipping Name, Hazar~ Gla~s, and ID Number) No, Type Quantity Wt/Vol I. Waste Number ""~ L,;:~;~ "t.lf.', ~:q R?~:'r)': ~?E,3U'~~''~''' f"~ O ] "~":"~ C'~ , : .......... ", Jr4/ ...... '~ EPA/Other b, State EPA/Other c. State EPA/Other d. State ~PA/other II I IIII J. Additional Description~ for Materials Listed Above K. Handling Codes ~or Wastes Li~ted Above 1~, Special ~un~lbQ Instructions ~nd Additional Inbrm~fion . :,' .'--,.." q. ~ 0 V ~ ~.~ & ~( u'~q~ ..... e;'~ DOff ~'t,~ 1:' ~' ~; ~'.t.~) [' [~. ~, ~.~ "":~ '~ ) ~ .'.~ '/"'0 .":~ .', ':.~ 1~. GENERATOR'S CERTIFICATION: I hereby declare that the contents oF thls consignment ~re fully and accurately d~cribed o~ove by proper shipping nome and are classified, packed, marked, and labeled, and are in oll respects in proper condition For transporf~y highway accord?g to applicable international and nationa/government regulations, I~ I am a large quanti~ generator, I certi~ that I have a pregram in place to reduce the volume and toxici~ o[ waste generated ~o the ~gree I have determined to be economically practicable and that IRave selected the practicable method o~ treatment, storage, or disposal currently available to me which minimizes the present and ~uture threat lo human health and the environment; OR, if I am a smafl quantity generator, I hage made a good faith effort to minimize my waste generation and selec~ IHe best waste management method that is available lo me and that I can afford. ; Printed/Typed N~De Signa~r_~..?:, · .......... ~ Monlh Day Year ' ', .' ' 'z:.:, ~'.:' I.m"'l ./I / 17, Transporter 1 Acknowbdgement of Rec.ipt of Materials -. "" Prihted/Typed Nome Signature ,,'" . .... , ,.,' ' .,,,'. ,:/'~ .~/ ,.,.'"..,~.~:" ~,~: ~:z, .. <'.. ..... , ....... ....... ,,.%.. ,. ~ / ,.:? 18, Transporter 2 Acknowbd]ement of Receipt of Materials ' ~',,: ..... 19. Discrepancy Indication Space 20. FaciJi~ Owner or Operator Certification of receipt of hazardous materials covered by this man.ifest except as noted in Item 19. Printed/Typed Name Signature Month Day Year DO NOT WRITE BELOW THIS LINE. IDTSC 8022A (1/99) EPA 8700--22 Yellow: GENERATOR RETAINS State of California~Envlronmental Protection Agency Approved OMB No. 2050-0039 (Expires 9-30-99) ,. "'-, See Instructions on back of r,-qe 6. Department of Toxic Substances ConlroJ print or type. Form designed for use an elite (12.pitch) "iter. " ~ Sacramento, California , UNIFORM HAZARDOUS i';-(J~ .... tor's us EPA ID No. Manifest Doc .... t Nd. "" 2. Page 1 Information ~n the shaded areas · is not required by Federal law, 3. Generator's Name and Mailing Address A. State Manifest Documenl Number ..... , :.~. , ~ 1 .... e, 5. Transporter 1 Company Name 6. US EPA ID Number C. Stale Transporte~'s ID (Reser~e~ ...... . ,. l~.... 1.,--~1, .... . · 7. Transporter 2Compony Name 8. US EPA ID Num~er 9. Design,ted F~cili~ Name and Site Address 10. US EPA ID Number G. State Facillty% .......... .. . H. Faci[i~% Phone 11. US DOT DescrlpHo~ [including Proper Shipping Ha'me, Hazard Clals, and JD Number) 12. Containers 13. Total 14. Uni~ No. Type Quantify Wt/Vo[ 1. Waste Number · EPA/Other c. State EPA/Other d. State EPA/Other ~, Additional Oe~cr~ptlons ~r Materlals Listed Above K. Handling Code~ ~or Wastes Listed Above 15. Special Handling Instructions a~d Additional InformaHon 16. GENERATOr'S CERTIFICATION: I hereby d"clare that the con~.nts o[ this consignment are [uHy and accurately described above by proper shipping name and ar. c]assi[ied packed, marked, and labeled, and are in all respects in proper condiHon for transportby highway according to applicable international and nationa/governmenl r.gulatlons. If I am a large quanti~ generator, I certi~ that I have a program in place to reduce the volume and toxiciff o~ waste generat.d to the degree I have determined ~o be economically practicable and that I have s~lect.d the practicabl, method ~} lrealment, storage, or disposal currently availabl, to me which minimizes the present and ~utur. threal ~o human healt~ and th. ~nvironment; OR, ii I am a small quantity generator I have mad. a good available to me and that I can afford. Pr~nted/TypedNa~e Signature [ Month { Day [ Year ...... ;" "' ' , ' , '~ ,:...:~, "...,, ...t, ..:~ : "'" i~ ' ".'f' r' ,,~, .~ ,..,,,.: " ,.18. Transporter ~ AcknowJed~ement o[ Receipt of Materials 19, Discrepancy lndicatlon Space 20. Facili~ Owner or Operator Certification of receipt of hazardous materials covered by this manifest except as noted in Item 19, Printed/Typed Name J Signature Month Day Year DO NOT WRITE BELOW THIS LINE. IDTSCB0~2A (1/99) Yellow: GENERATOR RETAINS EPA 8700--22 19 04 tZ:54p 90C*OCS 559 485 5495 I I I I I I I I I I I I I I I I Oil Conservation Service, Inc. 3256 N. Marks Ave. Fresno, CA 93722-4919 559-485.5495 FAX 559-485-5497 Receipt of used container(s) Oit Conserva[ion Service, Inc. has received the following containers: Generator SBC Phone Address (site) 3221 S, H Street City Address (mail) 2793 E. Foothill Blvd. City manifest # 23752008 / 23752011 EPA # County of Kern Permit # Contractor Hydrologue, Inc. Phone Addresa 2793 E. Foothill Blvd. City Cent, Tank AST/UST Malarial N~. No. Drum(a} 626-68S-9696 Bakersfield Zip Pasadena Zip CAT 080.020.514 Job # 626-585-9696 Pasadena Zip 1, BR-0320 UST Size 93304-5549 911O7 91107 Conten~ Steel/fiberglass 'SK Diesel Invoice No, 27912 Received By: Oil Conserva~ Inc. Name ~om ~.. Slgned~ ~ Date 0§-11-O4 Legend UST/AST 1. Underground 2. Aboveground Material 1, Metal 2. Fiberglas 3. PolylP{astlc Contents 1, Gas 2. Diesel 3. Waete oil 4. Butane/Propane 5, New Oil 6. Water 7, Av Gas 8. Jet Fuel Destination 1. Cut into scrap 2. Deliver to s recycler 3, Reuse* Destination SCrap I I I I I ~ OIL I CONSERVATION SERVICE INC. ENVIRONMENTAL SERVICES CONSERVATION 3256 N. MARKSAVE. THRU FRESNO. CA 93722-4919 RECYCLING (559) 485-5495 FAX (559) 485-5497 ENVIRONMENTAL PROTECTION AGENCY I.D, NO, CAD 980 673 842 DEPT. OF HEALTH SERVICES HAZARDOUS WASTE HAULER REG. NO 1943 TANK TEST CERTIFICATION I I I I. I' I I I I I I I Date: _-,~' / // /~'~/ JobNo.: TankNo,: I~//- ,,,¢, ~,,.2',,/';, TankSize: Prod. Unl. Gas [] Manifest No.: ~-~ '~7,~ ..~ ~:., I / Invoice No.: ..~ ~ / )~ Held: Lead Gas Diesel Waste Oil EPA ID No.: ~ ~T c,' ~ C:' ~ O :~T ~ L/ Other Generator: ~ ~ Phone: '~:::~ ' ~ .': C - ~:., ~:'~ Client: ~\,~, ~,,~.,,,,.:,~,~ -,. /<,,(L,/- Phone: .Address: ~']c/_~ ~ ..,_.:~2~(L/[,,.~J, ~.((/-r.(.". City:-~,. Test No. 1 Time: ,P" '."'-',--,, LEL: ! % Initial: Test No. 2 Time: /~,;?.' ,.z,o LEL: / % Initial: Test No, 3 Time: /4;,' :.,.~.~ ~. :'2, ,?' % Initial: Test No. 4 Time: LEL: % Initial: Test No. 5 Time: LEL: % Initial: O.C.S. Inc. certifies that at the time that this tank was tested by us it was free of flammable vapors. It may not remain vapor free. Treat this container with extreme caution, it may contain explosive gases. .. DO NOT EXPOSE THIS CONTAINER TO FLAMES, SPARKS OR EXCESSIVE HEAT, DO NOT CUT OR WELD ON THIS TANK. Generator's Signature Contractor's Signature County Inspector's Sign, ature I CONSERVATION I SERVICE INC. I I I CONSERVATION THRU RECYCLING 3256 N. MARKSAVE. ,, FRESNO, CA 93722-49i9 A59) 485-5495 X (559) 485-S497 ENVIRONMENTAL PROTECTION AGENCY I.D. NO. CAD 980 673 842 TAX I.D. NO. 7700979-34 DEPT. OF HEALTH SERVICES ~ HAZARDOUS WASTE HAULER REG. NO 1943 IGENERATOR'S CERTIFICATION: I hereby declare that the contents of this consignment are fully and accurately described below by proper shipping name and are classified, packed, marked and labeled and are In all respects In proper condition for transport by highway according to applicable international and national governmental regulations. I further understand that I may be held liable for ail costs incurred in the legal I disposal of all or part of any material which Is picked up but not specifically listed on the Invoice. Unless I am a small quantity generator who has been exempted by statue or by regulation from the duty to make a waste minimization certification under section 3002 (b) of RCRA, I certify that-I have a 3orOgrarn In place to reduce the volume and toxicity of waste generated the degree I have determined to be economlcallypractlcable and I have selected the method of treatment, storage or disposal currently available to me which minimizes the present and future threat to human health and environment. GENERATOR'S NAME No 27912 ACCT. NO. DATE ; " ',..~ '~'.'iff l~.:? TiME GENERATOR'S ADDRESS crry, STATE, ZIP EPA// NAME MAILING ADDRESS ! GENERATOR'S SIGNATURE P,O. NUMBER ORDERED BY ST, WASTE CODE EPA WASTE CODE MANIFEST NO. TESTED ,:;~'~ '~ 7,4.~' ..,.) .~ I. ...., · ,:, i ...... " - 2 6: c:t I ' LUBE 0IL IND. 0IL CODE TOTAL GAL, DRIVER TRUCK I,.~., .: ,.:t (..~. ~..~: /..:;,<;., ~ t.; - Z." .' DISP. QUANTITY UNITS DESCRIPTION CODE UNI,T AMOUNT · / NON RCRA HAZARDOUS WASTE, LIQUID (USED OIL/MIXED OILS) "NO PLACARDS REQUIRED" / / -.'/ NON RCRA, HAZARDOUS WASTE LIQUID NON RCRA, HAZARDOUS WASTE SOLID ETHYLENE GLYCOL SOLUTION <50% NON RCRA, HAZARDOUS WASTE LIQUID ...",,~ 4;, : :"> , -, < .. .-"" ..~' /. .... ,': .'-,~;',. 2 ~- "~' :.- ~:' ,.~..c' DOCUMENTATION FEE TERMS: NET 10 DAYS. ON PAST DUE ACCOUNTS THERE IS A FINANCE CHARGE OF 1.5% PER MONTH WHICH IS AN ANNUAL PERCENTAGE RATE OF 18%. IN THE EVENT OF JUDICIAL PROCEEDINGS TO ENFORCE COLLECTION, THE PURCHASER WILL BE LIABLE FOR ATTORNEYS FEES AND EXPENSE OF COLLECTION. SUBTOTAL C~STOMER'S SIGNATURE TOTAL 04/16/04 M'RR 18 2004 1~: 14 BKSFLD FiRE P~EVEMTIOM PERMIT APPLICATION FOR REMOVAL OF AN UNDERGROUND STORAGE TANK Page 1 o~ 1 [q.J uu3/ Ba~e~J~teld Fire Dept. Ea~ronmental ~C~ B~e~sficld, CA 9330 I (661)326-3979 I I I I I I I I I I I I I I SITE INFORMATION SITE · ADOA~S$ . · ' . ~'' ZiP COD~ ~ __ , I _~ .~,~ ~, ~~_ _ F~I~N~ ' ~ ~ ' ~ CO~CTOR INFOR~TION CO~A~ ' ~ONE No, LIC~ No I PRE~NARY ASSESSMENT tN FORMAT~N TANK CLONING IN FORMA~ON ~ ~,11 g/~ . I~ ~~a . ......... z,.cod~fl3.7 TANK T~BPORTER INFOR~TION TANK ~. ,AGE VOLUME b~l'C~E O STORED i - ' lC' 'C[~_,ct- . /.q~7- ~d- Fo~ Olfic~l Ue$ CX~dy APPL!C. ATION DATE I 'ACILITYNO. NO. O, ?ANKS JFe~$ ~1~ A~PLICATIO~ ~LL BECOME A ~ERMIT WHEH APPROVED I I I I UNDERGROUND STORAGE TANKS UST FACItJTY Bakersfield Fi:re Dept. ;L.,t,_~..~_&.:_.-:...~'...~_.~._~ Environmental Se~zices ~y,~.~ ~ ,~ . , .~, ~ 1.5 Chester A,,e ~e,t;~rm~,~r Bakcrsf'feid: C.A 9330' 'Fei: (65 ].)326-3979 1. FACILITY/SITE INFORMATION L ~ ~~¢t ................. ~ ' .~ 2. INOr/qDUAL ~ 5. C,'.'X;r~TF Ar, ENCY' 2 ~ eTR n j O ~ t PRO/'~ ~"QR ~OT E ~ ~ ,,~ ; ....... 11. PROPERTY OWNER INFORMATION I I I I ' III. TANK OWNER INFORMATION ' ' -- [rANx OWNrR N.At.tC ~ .. I ~ ~ ............ }- ........................ .; ,.,' rq~FFtqF .......................... ;';FI ~ ..... ~ ........... ~ ............... ~,' ls'r~ng-?, ..... CR. Coo~ .,,=, I I I I I I I I TANK OWN.:.F~ TYPE f~ CORPOflA'flON ~-J 2 INOtVI[JtJAI, ,-I 4 L, rOCAL ,&(,;iT:Nt;Y/ OI$1RIC'F -~ ri ::;'FA rE I'~ 7. ¢~DERAL AGENCY TY .'FK) } iV. BOARD OF EQUALIZATION UST STORAGE FEE V. PETROLEUM LJST FINANCIAL RESPONSIBILITY :T"J 2. rSUARANI':.E I~ 3. IN,~LIRANCE '% '~)9. O';HF-R ltl O. EXEMPT!ON .TI 7. $TA'II;; FUNO ,~ ,~. ST,%T~ gl.IN[)2, C.F~3 LETTI'~ 4;2 VI. LEGAL NOTIFICATION AND MAILING ADDRESS VII. APPLICANT SIGNATURE iSTATE US," FACILITY NUMO"-'~ i,r-ot /':.,c:fi :,'.':c' F.*ttiS? I I fd2069 I I I I I I I I I I I I I I I I I I TYPE OF UNII"II~I) PROGRAM CONSOLIDATEI) I;'ORM UNDERGROUND STORAGE TANKS - TANK PAGE I [-] t N}':W SI'H:. PF.I*,MJT I'-] 4 AN'IENI)IU) F'I~I.UvlIT [] ~ Cli,\N(J[i OF INI-"ORMATI()N [] ¢~ TI~MPoI~.:\RY SITE C'I.OSIJP, E TAN KS (two pages per ~;mk) d':hcckm,¢i:~m,nly) -- [] ,7 P[:.RM/\NENT{.YC'I.OSI!I~)ON $1'['E [] 3 (.tI'~NI.3V,\i. I~[~I,!NII'I' fSp*:cil~,, tm;on .. Ik~r lc,cai t,s< on{v), tSp~cily r¢;k4m,-, fi,r Iota{ r:'ie-nlyl ~4 TANK {{{~M()V{]I) 430 C.~/' , <.~v".r['..;~ ...' .... .... I .. . Id)CATION WH'I~IN SITE it)ptk,t;:d, . 4.H I. TANK DESCRII"I'ION (A scaled plot p{;ttl with the {ouat~o, ol'dt¢ {dS'{' system [nc{uding bt:/ldi~Igs a~Id {atld~tlat'ks sha}l bc submitted lo the iota{ t~ge~tcy. TANK ]1) TANK .\'l.:'s N U FAC'TU R L<R 'rANK ~~~,I.(3NS '~---, ," '. f"./ ' / .~ L. ~:. ~-,~ .................... A Il. TANK C()NTI{NTS I'I]'FI[OI.EUM TYPE ~ l~t. I~I':(]UI..,M{ UNI.I{ADI".I) ~ 2, i.I~.,M)EI.) ~ ~..lEI' FUI(I. ~ lc. MID('iRAD{~ UNLEADED ~ 4. (iAfi()[l(3l. ~ 99. ()'[1 II':R TANK USE 4yl [~1,, MOTCJR \'i!i{IC.'l,li'FUF. I, ' ~ 2, NON-FUEl. PIiTI(OI,EUM ~ 3, C'HI. iM1CAI. PROI)UCT ~ ,I. I TAZAId)OUS WASTE ~ 9~. UNKNOWN TYPE OFTANK TANK MATERIAL pri.,ap~;,,~ ,~l. {tARE STEEl. ¢~'hed. ,mc nt.m ,,fyi ~ 2. N'{'tXIN[.{~SS TANK M/x'FF. IMAI..-~;cc,,,d:tryt:,,,k [] I. Ih\RE STEEl. III. TAN K CONST R I ICTION --~]'"~.'?,~"~'[~i..li WAi:~---'--'[]' 3. ~INGI.E WA I.L WI'HI I~X'II{RIOR Ml":MI3RANI~ I..INI~R ~ ,I. SIGNI. g WALl., IN VAI.JI,T ~ FIBERGI.ASS / H.ASTIC ~ ,L S'I'[?:/;:I. CI,AI) W/I:Ili[iI~GI,ASS I{liINFORClil) PI,ASTIC I"RP) ~ 3. FIBERC;I,ASS / PI,ASTIC ~ ~. STAINI.ESS S'I'EEt. t. STEEL CI.AD W/FIItERGI.ASS RI!INFORCI:~I) PLAS I'{C {FRP) ~ 5 I ~ SINGLI?~ WALl. WI'I'll INTI~RN:\I. IH.AI}I.)I.~I{ SYSTEM [] 9.5. UNKNOWN [] 99, ()TI lEE [~'5, CONCI~I:~'I'I~ '~ 95, UNI<,N()WN [] X. I:1(1' C(')MP'I'IliI,I{ ";v'/100% MI!'I'IIAN{ )1. ~ ,19. •TILER [] 5. CONCRETI:', [] t: 5. UNKNCIWN [] ~. FRP COMI"HIU,E W.qO0'!'; MI!TIIANOI, [] '0% O'H lEV, [] I0. CCh\Tl.~l.) ,%."['liliI. TANI<. INTI~I,UOR I.INING [] I. I~,UBI'~I,~R I,INI':D ~ 3. EPOXY L,INING [] .% GI,:\S.q 1.1NIN(; i~ '4.% UNKNOWN 44,, I)ATI~ INS'I',.\LLEI.) .i47 OR ('OAI'IN('i [] 2 .,\LICYD L,ININ(,; [] 4 I'I.{EN()I,IC LINING .'~'6 UNI. INI~D [] 99 ()'I'IIER .............. •TI IF.l), CORIU.)SI()N [] i MANUFACTURED CATIIOI.BC ..L,~,3 I:IBEI'RJ., \.'SS lq!IN Ft')I~,Ct'~I'') PI.ASTIC I"Rc.)rI'I!CTION H':/\H~I..IC.,\[]£.I~ f'I{OTECT'ION [] I h'vIPRt(SSI-~I) CUI{RI.iNT ~('):~,c{, ,',nc i~cm ,,g' [] 2 S,,\CRIFICI.,\L/\NOI)I.~ SPILl. :\NIL} (.)VF.I'U:II.I. "/E/M{ [Ng;[';\i.l.l{l), ¢,' .L~0 T'I'P}~ d,,:,l ,..,¢ ~mlyl 431 ()V'I:~I'WIL. I.. PR('H'IZCTION( EQUI F'MI!N'I';Y 1':..\1< IN..K'I'..M.I.I~[') .L';.'.. I SHI.L CONT,.\INMENT,.... --'1%'...~ 'N-'ii, 1 AL,.\P,M I,O~ ',~; 0 3 FII. L 'I'UI',~E SHUT OFF \":\ L \,'E IV. ]'AN K LEAl( DETECTION A d~.':it'ril~tkm ol':h¢ mol;itorm~. 0rogm:u ~I a ~t~ $ ibl:litt..'d to: c Dc I ge,gr., hu' SIN(il..[~ \V.,\L k T.,\NK tC'he,.k :df:hat apfly~ 433 I}" DOUBLE \V..\LL T.&NK OP, TANK WITH Bt.,:\I)DF:P, 4.~a {~ ! V'ISUAI. tEXPOSED PORTION ONI.Y~ [] 3 M:\NUA't. TANK. G,,\UGING I NTT'G} ] [] I VISU:\L ~$iNClt. E \V.,\LL IN V:\ULT ONLY~ 7'] 2 AUTOMATIC T,.\NK CL,\U(;ING I:\T(1) [].6 V,,\DOSE ZONE ,~CON'HNUOLI$ INTERSTITIAL MONH'C)RIN(; ~ .~ CON'/'/NUOU$ ATG [] 7 GROUNDWATER [] 3 .MANUAL .\IONfFORING [] 4 .qT:\TI$'rlCAL IN\:ENTORY RECONCILIATION [] 8 TANK Tt;STiNG tS[I~,I BIENNIAL TANK TESTING [] 99 OTHER 1V. TANK CLOSURE INI:OR31A'rlON / F'ERMANENT CL()SURE IN PLACE ESTIM..\TED D..VI'~ L..\$T USED iYR. MO/DAY~ 4.~3 [ I."$ThM..VI'EI3 QUANTITY OF SUL~$'I'ANCE REMAINING 4.% T.\NK F'It. LEI.3 WITIt INL:.R'I' M:\ l'l'i~Rl.\L'.' .1::' U PC F ( 12,'99 revised) 10 Formerly SWRCB Fom~ B I I I I I I I I I I I I I I I I I I UNIFIED PROGRAM CONSOLIDATED FORM TANKS UNDERGROUND STORAGE TANKS - TANK PAGE 2 VI. PIPING CONSTRUCTION (Ch¢ckalllhat:tppl,v~ . Proc .I ._ (JNDERGI~OUND PIPING AI-~OVEGROLJND PIPING SYSTEM TYPE ~ I. PIU}SSURE '.~.'2, SUC'I'IC)N ~ 3, GRAVITY ,~ ~ I. PRESSU[{[~ ~ 2. SUCTION ~ L SINGt. E %VAI,L ~ 3. LINED 'I'[(I~N(':I,I ~ 99. OTIIER ,1(o ~ I, SINGLE WAi. L ~ 95. UNKNOWN ~ 2. DOUI]LI,:: W/M,I,, ~ 99. OTIII":R ,t b l M A N U FAC'I'U R E H ~ ',,';i ~,\("l ~,.,1~,,~ [,~OUI,tlJ~ WALL ~ 9~, U~K~OWN ~ [. BARI~ ~TEEI. ~ 6. FRP COMPATIBI.L~ w/lOo% MI.:rlIANOI. ~ 2. STAINLESS STEEL ~ 7, GALVANIZED STEEl. ~ Unk;town ~. 3.. PLASTIC COMPATIBI,I~ %V/ CONTENTS .~ .~, FII~I~RG[.ASS ~ 8. I:l,l~Xil,l[,l~ (Ill)i'll) ~ ~. STEEl, ~V,'COA'I lNG ~ 9. CATHODIf,~ PI~OTI~CTION I--I I. BAP, E STEEl, [] 2, ST,\IN[.ESS [] 3, PI,ASTIC COMPATIIII,I,~ W/¢:CIN'I'I'/NTS [] ,4, I:IIlEI{GI.ASS [] 5, STL~EL W/COATING VII. I'll)lNG I,EAK DF, TECTION ~(:h~: all :ha~ aprLI;,,~A ( UNI)I'::I~GI'~f)IjNI.~ PIPING · SINGI,E WA.L[, I'IPIN(; PP, I{SS U I'~ [ 7. ED lq PING I (.'h~:vk nil flutt apply): ~ I, ELECTRONIC I,{NIZ I,I'~AK I)ETECTOR 3,0 GPll TEST W,{'I'II AUTO PL;MP SHUT OFF FOR I,EAK, SYWI'EM FAILUliiL AND SYS'I'IZM I)ISCONN[~C'I'ION AUD[BLI'~ AND VISUAL ~ 2. M()NTI'II.Y 0.I (.iPll 'I'I[ST ~ 3, ANNUAl, I N'I'EG RITY 'F[SS'I' C'ONVENTION,,M. SUCTION SYSTEMS VISUAL M(~NI'I'(;.I.UN(i OF PUMPIN¢1 S'YSTI:',M I. TRII~NNI:\L PIPIN¢,i ,,\IJOVI'iGI~OLiN D PIPING SINGI,I,: W^l,I, PIPING [--[ ]. I.iLECTP, ONIC LINf': LEAK D~'I'ELTI'OR 3.0 GPH 'I'E~T WI'HI A~TO PUMP ~II~T OFF FOR LEA~.~W['EM FAILURE. A~D AIJI)IIILt~ AND VISUAl. AI.,,%RMS. ~ 2, MON'HII.Y 0,2liPIl'l'Egl' ~ 3, ANNUAl. I N'ITKiRH'Y 'I'EgT (0, I ( iPlh ~,1, DAILY VISUAL CON VHNI'IONAI. SLIC'I'ION SYS'I'I'~N'I N iChcck all dral apply) ~ 5, DAII,Y VISUAl. MONITORING Ol" PIPING AND I'UMI'IN(; S't'S'I'EM IN'I'I::( HII'I'Y 'IT':ST (Il. I (iPlll ,";AFl", SUCTI()N SYSTIiMS IN(,) VALUI!S IN III!,I,(IW (iI/OIJNI)I~IIqN(;); ~ 7, SELF MIINI'r'oI/ING GRAVITY FI.O\V [] '.1. ItlI/N NIAL INTE(iIUTY 'Fl.;ST {o. I (il'I Il SI,:C( )N i)A Ill I,Y C( )NTA I N El) I'1 I'1 PRI2S$ UIt. IZI!I) PI PI,"IG tt:ll~:ck till Ih;il apply I: CONTINUOUS TUIIBINI~ SUMP SENSOR ~¥.[[1:l AUl]II.II.E AND VlStJ,,\L ,,\I,,ARM,S AND ICheck oIv:l f-] a. /\UTO Iq.IMF' SHUT O1:1" \¥HEN A LI.:.AK OCCI.iP, S [] 6, 'I'I,III~NNIAI. INTEGRH'¥ TliST I'll, ] sAr:r'.' SUCTION SYSTEMS INII VAI.\/t!S IN II1,,I ,OW GROUND t)II'ING I: [] 7. SELF MONITORING Gib\VI I'Y FI.O\V IuIml:k ull ihal apply l: [] 8, DAli,",' VISUAl. MONI'I'OI,UN(,i [~ q, hlII.:NNI:\I. INTt!GI'UT\' TI{ST !l,'l,l ,.~1,: C¢ IN II,,I I,{I I .Y ¢,;¢)~TA I N Ell PI PING IqI. I'Lq,qUIUZt.",I) PIPING II 'hu¢t, all ~hal iq,ldyl; I0. (.:fin I'INUOUS 'TUI,H,IINI! SUMP SENSOR ~[(J'.[[J AUDIItL,I[ .,\ND VI',~U,.\I, [] a AUTO PUMP $11UT Ol:l" WHEN A [] b. ^UI'O PUMP SIIUT OFF FOR LEAKS, SYS'f'I!M FA II. UIII".' AND SYSTEM I)ISCONNECTION ~c. NO AIJTO I'UMP SHUT OFI" ~ I 1, AUTOMATIC [.INE I,EAK I)E'I'I,~CI'O~ 13,0 GPI I 'F~WI') ~'.[[~ H.OW 8IIU.T OFF OR I(ESTlilCI'ION ~ 12. ANNUAl, INTEGRITY '1'1]~'I' ~0.1 (il'HI SUCTION/( iRAVI'I'Y ~ 13. CONTINUOUS SUMP SENSOR't AUI)IBLE AND VISUAl. Al.ARMS EMERGENCY GENI,'.RATOIIS ONI.Y Iqhcck all Ih;il apply} .~L CON I'INUOUS ,.~UDIB~ AND VISUAl. ALAItM~ ~ 1~, AUTOMATIC I.IN~ ~AK I)tYI'ECTOR (3,0 fil'N Tt~'l'l ~i~l~ FLOW ~H UT OFF OR RI~'FRIUTION ~ I~, ,,~liAl, I~TEGtU'I'Y I'I~S'I' IlL ~ IZ DAILY VISUAl. CHECK [] b /\t;'l'O PUMf' SHUT OI':F FOIl I.I:,AKS, S'FSTI'~bl F,\II,L;I.tI{ ,\ND .SY.STI:M, I)ISCONN}XiTI(IN []c NO AUTO I~LIMI'' SI IUT OF[: 11. AU'I'OM:\ I'IC lA!AK DI'i'I'I:!CI'OI'~ 12. ANNU.,\I. INTEGiU'I'Y TI~STI0, I GPlI) SUCI'ION/GltAVITY SYSTFM I';MERGI~NCY (;I'2NERATOI{S ONI,Y ~c:l~¢ck all dut~ apply) 14. CONTINUOUS SUMP SENSOR ~12E!:t9.~Ii AUTO PUMP S}IUT OFF ' AL'DIBLE AND VISUAL ALARMS 15. AUI'OMA'I'IC LINE I.EAK I)ETEC'FOR O,0 GPH '1'ES'I'~ 16. ANNUAl, IN'I*E(iRrI'Y TEST eL 1 qiPI{) 17, DAII. Y VISUAL CIIECK VIII. DISPENSER CONTAINMENT DISI'FNSEII. ('05; I',\INMEN I' [] I, FI,OAT MECIq,\NISNI TII,Vi' SIIU'I'.'q OFF .ql'll.:Al~ \:,\t,\"l~ [] 4. DAll.Y VISUAl, CI DATE INST..\L. LEL) 4o,s [] 2, CONTINUOUS DISPENSER PAN SENSOR. ~. :,\UDIBLE ANI) V'ISUAL ALARMS [] .~. '[I(ENCIt LINER .' MONIT¢)RING [1 [] 3. CONTINUOL~S DISPENSER PAN SFN$OI~. ',~..H AL:TO SHUT OFF FOR [] 6, NONE '~'"" DISPFNSER 4- AUDIBLE AND VISUAL ALAP, M$ IX. O'WN ER/OPEIL:VI'OII SIGNATURE ]t~K;OP£RATOR UPCF ( 12/99 re\.'ised) l 2 Formerly SWRCB Form B 05/05/04 I ~ ~-dA K E R $ I~ ! E L D I ~{JK/SW¢ IN(; PRE¥~HTIOM FAX Transmittal COVER SHEET 008/012 p.! ! ! FIRE DEPARTMENT PREVENTION SERVICES 1715 Chester Avenue · Bakersfield, CA 93301 Business Phone (661) 326-3979 · FAX (661) 852-2172 TO: COMPANY; FROM: ~¢O~T$: I 05/05/04 11:01 ~§820§31oZ0 MJK/$WC 18 2004 1'/: 14 BKSFLD FIRE PREVEHTIOH PERMIT APPLICATION TO CONSTRU¢?IMODIFY UNOERGROUND STORAGE TANK I I I I I TYPE OF APPLICATION (CHECK) O NEW FACILITY O M~OIF-ICAI'~ON 0;: FACILITY INC (GG1 ) 009/012 p.3 Bakersfield ['ire Dept, Enviroxxmental S~rvice 1715 Chester Ave Bakersfield, CA 93301 Tel: (661)3~6-3979 TANK INSTALLATION AT EXISTING FACILITY I I I I I I S70 I FOR OFlCI¢IAL ~$E ONLY The u. vt~llcant has received, understands, and will comply with the attach,d ¢ondition~ of the Fermit and an), othz stat% tocat on~}/~qeral r~gulation~. Thi~ fo~ ha~ been ~mplzt~d ~der penal~ of ~ peru,. ~ ,o th~ b~, ~ ~owl~e. U ,~ and ~,. ~ 'aA THIS ~PLICA~ON BECOM~ A PERMIT ~EN APPROVED 0.9/05/04 11:01 '~'582 § § 31,., "0 MJK/SWC INC m,, .M~l~ i8 ~004 17:14 BKSFLD FIRE PR~VEMTIOM PERMIT APPLICATION FOR REMOVAL OF AN UNDERGROUND STORAGE TANK Page lo( 1 m ! m m m m ! I I I I I m 'V m ~]010/012 p.~ B~dr. et~fleld Fire Dept. En~Lmnmestte/E~e~ces l? 15 C~ester Ave B~ersfiel~, CA 93301 Teh (661)326-3979 SITE INFORMATION ' CONT~CTORINFOR~TION pREL~NARY ASSESSMENT iNFoRMAtiON ~ ' " { TANKCL~NINGiNFORMATION TANK ~NSPORTER INFORMATION CHEMI~ 0ATES ~MI~ ~TANK ~, AGE VOLUME ~ ~T~ ~E~SL Y~TO~ED THIS APPLICATION WILL BECOME A PERMIT WHEN APPROVED m 05/05/04 MJK/SWC INC APPLICATION TO CONSTRUCT/MODIFY [J~I'I~ERGROUND STORAGE TANK I I I I I I I 011/012 TYPE OF APPLICATION (CHECK) O NEW FACILITY O MODIFICATION OF FACILITY %~,~NF.W TANK INSTALLATION AT ~XIiTING FACiLiTY F,,;,~,-~,_ .- /.. . PMON~ N , RIEFLY~RIBE THE ~K TO Bakersfield Fize Dept. Environmental Service "' !.7 [5 Chester Ave Bakersfield, CA, 9:330 l Tel: (66[)$26-3979 I I R TC REGUI..,~ I ,I I i I I I TM, IK NO. VOLUMe. ( UNL,E~g[O "~I~ sECllON lB FOR NON MOTOR FUEL ~'TORAGE TANKS FOR, OFFICIAL USE ONLY ~ ~au $  '~'~CATIO N DATE The a£plicant has received, understands, and will comply with the attached conditions of the permit and any othu state, focal an~edaral re~lation~, Thief otto ba~ ~e~n completed under p~nal~ of THIS APPMCATION B~:OMES A P~R~IT WHEN APPROVED I 05/05/04 11:0~ ~IJK/$W¢ INC ~011/01~ ,,~ ,' CITY'OF'BAK~,'~SFIEED ' ' ' "' "'~'"0FFICE OF ENVIRONMENTAL SERVICES 17IS Chester Ave,, Bakersfield, CA (661) 326-39'79 I.NSPECTIO~ RECORD _P_OST CARD A.T JOB SiTE INSTRUCTION~, Pl~ae call t'or ~ inap~cior onb' whm ~h ~eup of Inq~emto~ with ~umb. oF~qui~d i~p~on Vjli~i a~d ~he~tb~ p~ ~t o[addi~on~ ~. ; TAN~ ~O ~CKFI~ PIPING SYST£M ~ng'& R~eway'w/C~lle~don ,S~mp I I I I I I I I I I I i APPENDI'X E: SOIL SAMPLING PROTOCOL All soil sampling ,.vas conducted under the direct supervision and al:~proval of the Regulatory Agency Inspector. UST SAMPLES Soil sampling wa~. accomplished by the backhoe bucket approximately 2 to 4 feet below, the former UST. The soil sa~.nples were collected in two 2.5-inch diameter by 3-inc!l long brass sleeves. A HI geologist collected the soil ~;amples from soil contained in the backhoe bucket b!., manually pushing a clean brass ring with one end seal ::d with aluminum foil and a plastic cap into the soil. !:ollowing sample retrieval, the other end of the brass r ng was sealed with Teflon foil and a plastic cap. The s :>il sample was sealed with Teflon or Arlon tape, label~'d with the sample identifications, date and time of,'.ampling and HI project number, and immediately placard into a chilled ice chest using frozen blue and c:ushed/ce. The sample was logged on chain of custody 'ecord forms and delivered to the State Certified L;,boratory for hazardous waste testing (Appendix A). STOCKPILE SAMPLES Soil samples IDs prefixed with "SP" were collected from soil excava~ ed and stockpiled during the USTs removal activitie i; (Figure 2). The soil was excavated during UST excavation activities and stockpiled on Visqueen plastic sheeting adjacent to the excavation. The stockpile soil samples were obtained by hand augering approximately one foot into the stockpile. PRODUCT PIP lNG SAMPLES Soil samples IDs prefixed with "P" are collected undisturbed from the piping excavation along the former product 1: iping associated with the UST. Soil sampling was ac zomplished by hand augering approximately 2 ½ to 4 feet below the former piping invert and then cbtaining a soil samples using a stainless steel hand core sampler equipped with a sliding drive hammer. The soil samples were collected in two 2½-inch diameter by 3-inch long brass sleeves mounted within :i 2½-inch diameter hand core sampler. The drive sampl.~r was hand driven into the undisturbed soil at each sampling depth. The soil samples were pr.)perly labeled and handled as described above FUEL DISPENSER SAMPLES Soil samples [D:~: prefixed with "D" are collected undisturbed frorq below the former fuel dispensers associated with .:he UST. Soil sampling was accomplished b',' hand augering approximately 2 ½ to 4 feet below the fi}rmer dispenser and then obtaining a soil samples using a stainless steel hand core sampler equipped with a sliding drive hammer. The soil samples were collected in two 2½-inch diameter by 3- inch long brass sleeves mounted within a 2½-inch diameter hand core sampler. The drive sampler was hand driven into the undisturbed soil at each sampling depth. The soil samples were properly labeled and handled as described above. Prior to use, all sampling tools and implements were washed in a non-phosphate cleanser solution, rinsed with tap water and then distilled water. EPA METHOD 5035 This section is only applicable if warranted by permit and/or regulations. The sampling and preservation protocols uses the ESS Lock N' Load 5035 Soil Syringe Sampler (or equivalent). The Soil Syringe Sampler sampler is a one-time use tool which collects approximately 5 grams of soil. The soil collected from the Soil Syringe Sampler sampler is then transferred into pre-weighed 40-mL vials with appropriate preservatives. Method 5035 requirements for sampling and preserving soil can be met in 2 ways: [] VOA vial prepared with sodium bisulfate preservative (5mi of de-ionized ultrapure water and I gram of Sodium Bisulfate preservative) - low level volatiles. Once in the field, Hydroiogue will measure out 5 grams of soil with the Soil Syringe Sampler or equivalent and add it to the VOA vial. Since the entire ~ sample is consumed during each test, H1 will use two VOA vials per soil sample boring. [] Standard boring sleeve followed by preservation in the lab - both high and low level volatiles If necessary, HI will also use the following: [] VOA vial prepared with methanol preservative (5 m~ of methanol (MeOH))- high level volatiles. Once in the field, Hydrologue will measure out 5 grams of soil with the Soil Syringe Sampler or equivalent and add it to the VOA vial. Each methanol sample can be analyzed more than once; therefore, only one method VOA is needed. The methanol solution becomes the actual representation of the soil sample being submitted. Since the MeOH virtually "masks" the low-level analytes, only volatiles with concentrations exceeding 200 ppb appear when analyzed.