Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
UNDERGROUND TANK FILE #2
I I I I MODERN- WELDING 'CO.,INC. iMODE WELDING Underground DoUble Wall Tanks · Bulk storage of flammable and combustible liquids · Available in Modern's Glasteel fiberglass cladding (.composite) coat ng · Bulk storage of hazardous and toxic materials Up to'specific gravity of'1.1 (complies with ACT-100) or sti-P3 cathodiccorrosi0n protection system (Tanks can be modifiedt0 store heavier liquids) · 30-year limited warranty · Built to Underwriter laboratory UL-58 and UL-142 requirements using ·. full UL-58 thickness for maximum strength . TECHNICAL DATA: Surface Icad, per axle- (h-20) - 32,000 lbs. Pressure- · Meet requirements of NFPA 30 and 31, Umform Fire codes and EPA 280 20 t ' ' ' · atmospheric. All:{ TESTING: Air test at no less than 3 psi nor more than 5 psi. · Built of carbon steel, stainless steel, or a combination of both · Priman/tank to be pressure tested with pressure in primary tank. At no time shall · Available with internal linings for jet fuel, acids, alkalines, and many other pressure in secondary tank exceed pressure in pdmary tank, products .~ ' .. :. .... ULTYPE 1-360° Containment I~I! ~ i N (300° part/al wrap is available) Threaded Fitting D ME SIONS ' ' " ~ ft ~ '~ GALLON APPROXIMATE OVERALL . I Monitor [.. Hy ~' , CAPACITY TANK DIA. ' LENGTH WEIGHT Secondary ~j.; ~ Opening ~ ~_~._~ ~ ~_ · Tank .~_ ~ ..... T~,,i_=.J'% .~_,L~ ~ .......... ~ _ .'=, _~=_.._ S.~ 1,000 64" 6'6" . 2,150 b ~" i ' ~ · Ii ii Ontional Manway I1! 2 000 64" 12'6" 3 500 lb. ,'.:' . ,', : 1' All Manways and fittings optional Iii 3,000 64 18'6 4,930 lb. 'i i '~\ :1 tI (Customer specifies locations) ~li} 4,000 . 96" 11'6" 5,600 I.b. _.~! ; ~ il Il ~ '4000 64" 24'6" 6 020 lb. - ' (~ ' Prima ¢ i I 5 000 96 14 8 500 lb. ,~ ry ./~ ; Secondary tank wall fabricated to be in !Ii! 6'000 96" 16'6" 9 700 b · '"'~ Tank .... , ! intimate contact with primary tank !Ii! 8'000 96" 22'6" 12'100 b' . "..~ <.. ; ;I · ' ~1 10'000 96" 27'6" 14;500 i I ~ I 20,000 1 26" 3'~ '6" 23,500 lb. ;-~--- Diameter ~ ~----------------- Length - -~ Other sizes available ' .'.. ',::':"'~.'?' t:,:.~ '.:' ?~;h~':~:?~'t ~:~:~/C~;~?~'~ :, ~L~" %"h ' , UL TYPE 11-360° Containment o · . . DIMENSIONS · (300 partial wrap ~s available) Secondary tank wall thickness is'the same as ' ' ' ' if~ GALLON PRIMARY SECONDARY pnmary wall thickness unless otherwise spec ed. CAPACITY TANK DIA. LENGTH TANK DIA. LENGTH WEIGHT Secondary Monitor Lifting ' ~ _ . Tank [ O enm Lu Standard Center rotting ~ P ' g g ~ II ' ' 1,000 64" 6' 68" 6' ~,4251b. % .~ ~ro=~_-z~____~__~.S~]_Z__[.=c~__-=__2_~3__~_ _p,_. m .~, 2,000 64" ' 12' 68" 12' 5,5051b, ~¢ , -- %. /I ~ Opt onal Manway . ~ ,I 3,000 64" 18' 68" 18' 6,235 lb. ,,~' ; ' {\, ~ All Manways and ftt ngs optional 4 000 64" 24' 68" 24' 8 219 b / I (Customer specifies Iocabons) // .',t . ~1 . ~f II 5,000 96" 13'6" 100" 13'6" 11,150 lb, ~_-_~--~' ~-_--~_-:-_-----_--~-_--_-_-:-_"---__--~--~_--_--~-_-~-_2~ 6,000 96" 17' 100" ' 17' 129501b. \~ --P'~:ma~ - j? !1 ~r!' , · ',ii, I1 8 000 96' 22' 100" ' 22' ' 15 925 b '"~' Tank ×Y II ~':-- ::"-'----- - ---= ='- ---'- =--'-- =: ::: 10,000 96" 27' 100" 27' 19,100 lb. '~--L-~ .~¢~ II _~ ~_ ..... - ......... J~ II 12000 96" 32'- 100" 32' 21 900 b '-'~--'" ' -- -~ .... ~ ......... --~ 0'0 12 I 13 I 38'5 0 Ib ' I 2,00 6" 3' 0" 3' ,5 . . i' Length I Other sizes available ,~_ Optional Containment Dam (typ.) ~*~I Modem Welding Piping Sumps can be fitted Monitor (Center on Fittings) ~ to all Double Wail and Single Wall Tanks { Open ng L ff Lug ~ ~ ' (Available in 16" 22" 36" and 48" I~ ~ .... f ~ ':' =~-c~D-.~,* Optional ¢¢~ I ~ I Dlamet rs) / ' If i! il Ii' iii !11 s,.. : ! . ! ' ' ~ i ;~i'~ [i Reversed F anged It / I' Containment ~- D~ameter -.4 h Length --- ~i~ . ' RJ GION sHIP'NTB REDUCE sHIPpiNG COSTS! Contact the Modern Welding Company Subsidim'g nearest you for pr[ce and deliverg. co.; Coroorate Office ' MODERN WELDING COMPANY, INC. MODERN WELDING COMPANY OF TEXAS, [NC. MODERN WELDING cOMPANY OF OWENSBO¢:.~ 2880 New Hartford Rd., Owensboro, KY 42303 715 Sakowitz St., Houston, Texas 77020 ~ 1450 E. Pardsh Ave., Owensboro, KY 42303 Phone: (502) 685-4400 Fax: (502) 684-6972 Phone: (713) 675-4211 Fax: (713) 673-4062 Phone: (502) 683-5323 Fax: (502) 684-5245 MODERN WELDING COMPANY OF GEORGIA, INC. MODERN WELDING COMPANY OF IOWA, INC. 300 Prep Phi/I/ps Drive, Augusta, Georgia 30901 2816 Mt. P~easani Rd., Burlington, iowa 52601 ' Phone: (706) 722-3411 Fax: (706) 724-8133 Phone: (319) 754-6577 Fax: (319) 754-8428 MODERN WELDING COMPANY OF OHIO, INC. MODERN WELDING COMPANY OF FLORIDA, INC. 72 Wa/do Si,, Newark, Ohio 43055 1801 Atlanta Ave., Orlando, Florida 32806 American made Phone: (614) 344-9425 · Fax: (614) 344-6018 Phone: (407) 843-1270 Fax: (407) 423-8167 MODERN WELDING COMPANY OF CAL FORNIA, INC. 4141 N. Brawley Ave., Fresno, California 93722 I phone: (209) 275-9353 Fax: (209) 275-4381 I M°d n Welding Compan ,'lnc. 'PO Box 1450 '- OwenSboro, KY - 42302 . Subsidiaries Nationwide -. (502)685-4400 LONG FORM: Section 13215 Guide Specification Modern Welding Company GLASTEEL Double Wall, SteeVFRP Composite Underground Storage Tank 360 Degree Secondary Containment GLASTEEL DW I I PART I General 1.01 Related Work Specified in Other Sections A~ Cast-in-Place Concrete: Section 03300 B. Anchor Bolts: Section 05501 C. Plastic Pipe: Section 15064 D. Liquid Level Gauges: Section 15174 · composite underground tank for flammable liquid storage and the ACT 100 label for corro- sion protection of underground storage tanks. D. Installation Instructions: Contractor shall submit copies of manufacturer's' current installation instructions. I I I I I I I I I I 1.02 A. 1.03 ,4, Quality Assurance Acceptable Manufacturer: Modern Welding Company, Inc. Governing Standards 1. U.L. 58, Underwriters Laboratories, Inc., Steel Underground Tanks for Flammable and Combustible Liquids. 2. ANSI B137.1-1971 3. ACT 100, Steel Tank Institute Specification for the Fabrication of FRP/Clad Underground Tanks. 4. NFPA 30 and 30A, National Fire Protection Association Flammable and Combustible Liquids Code. 5. Uniform Fire Code, International Fire Code Institute. 6. U.L. 1746, Underwriters Laboratories, Incj Corrosion Protection Systems for Underground : Storage Tanks. 7. PEI/RP 100-90, Petroleum Equipment Institute, Recommended Practices for Installation of Underground Liquid Storage Systems. Submittals Shop Drawings: Contractor shall submit. copies of shop drawings for each tank. Location of fittings and accessories with specific. dimensions shall be shown on all drawings. Catalog Data: Contractor shall submit ~ current copies of manufacturer's literature. Certification: Each tank shall bear the U.L. 1746 listing mark for Secondary containment PART II Products 2.01 GLASTEEL Underground Storage Tanks A..Loading Conditions: Tanks shall meet the following design criteria.' 1. Surface Loads: When installed according to manufacturer's installation instructions, tanks shall'withstand surface H-20 axle load (32,000 lbs/axle). 2. Internal load: Primary and secondary tank shall withstand an air pressure test of 3-5 psi. 3. Tanks shall be designed to support accessory equipment such as ladders, submerged pumps, containment sumps, etc. when installed according to manufacturer's instructions and limitations. 4. Tanks shall be designed in such a manner to provide for monitoring of the interstice. 5. Primary tank shall be designed per Under- writers Laboratories, Inc. #58, Table 3.1. and secondary tank shall meet Underwriters Laboratories, Inc. #58, Table 3.2 criteria. B. ·Product Storage Requirements 1. Tanks shall be capable of storing liquids with specific gravity up to 1.1. 2. Tanks are designed for operation at atmospheric pressure only. All primary tanks shall be vented. 3. Tanks shall be·capable of storing gasoline, gasohol, jet fuel, diesel fuel Or methanol at · ambient underground temperature or used for fuel oil at temperatures not to exceed 150 degrees Fahrenheit. 4. The interstice shall be monitored Using a static monitoring system. I ! I -I I I I' I I'1 I I I I I I I C."Dimensiona] Requirements '- . 1. Nominal capacity of the tank shall be __ gallons. 2. Nominal outside diameter of the tank(s) shall be __ inches. 3. Overall length of the tank(s) shaH. be approximately __ feet. 2.02 Accessories Certification Plate: Underwriters Laboratories, Inc. label and ACT 100 label shall be affixed to each tank. Fittings - NPT 1. All threaded fittings shall be of a material of construction consistent With the requirements of the Underwriters Laboratories listing. All fittings shall be protected using threaded plugs or suitable covers. 2. Standard fittings Shall be 4" NPT forged steel weld flanges. (If required by regulation, a 5" NPT forged steel weld flange with 5"x4" nylon ' dielectric bushing may be used). 3. Interstice monitoring opening shall be 3" forged steel weld flange with 3" x 2" nylon dielectric bushing installed~ 4. Location: Refer to drawings for location. C. Interior Ladder: If required, supplied by tank manufacturer and designed to provide for tank deflection. Do Manways (optional): 1. All manWays shall be furnished with U.L. listed gaskets, bolts, and covers. Containment Piping Sump (optional): 1. As .'reqUired, sump may be used for secondary containment at the submerged pump location. F. Interior Paint and Coating: 1. If required, see Paint Section. G. Anchor Straps: If required, .provide fiat carbon steel anchor straps for each tank. The number, size, and location shall be as that shown on the ' contract drawings. A suitable dielectric material' shall be placed between the strap and tank at time of installation. H. Lifting Lugs: Suitably designed and located lifting lugs or lifting plugs shall be provided with each tank and be capable of sustaining the tank weight with a 2:1 safety factor. PART III ExecutiOn 3.01 InstallatiOn Tanks shah be installed in strict accordance with the most recent installation instructions provided by the tank manufacturer, PEI/RP100, NFPA 30, UFC, local ordinance, or other applicable codes. 3,02 Testing Bo The tank shall be dehvered to jobsite with a vacuum Of at least 5.3 inches Hg on the inter- stitial space. If the minimum vacuum is main. tained for one hour, the inner tank and outer tank may be considered properly tested. Alternate: The primary tank shall successfully . complete an air pressure test of 3-5 psi prior to or at the completion of installation. WARNING: Pressure testing of the interstice shall be in strict accordance with manufacturer's instructions: Do not overpressurize. C. A volumetric test shall be performed on the entire storage system prior to being placed into operation. FORM GLASTDW © 4/93 MODERN WELDING CO, lNG SUBSIDIARIES: Corporate Office (502) 685-4400 : Modern Welding Company of Owensboro, Inc. (502) 683-5323 Modern Welding Company of Ohio, Inc. (614) 344-9425 Modern Welding Company of Florida, Inc. (407) 843-1270 Modern Welding Company of Texas, Inc. (713) 675-4211 · Modern Welding Company of Iowa, Inc. (319) 754-6577 Modern Welding Company of California, Inc. (209) 275-9353 Modern Welding Company of Georgia, Inc. (706) 722-3411 Underpump Valves A438 Foot Valve, Single PopPet Emco Wheaton foot valves have been a recognized industry standard for nearly thirty years. The A438 Foot Vaive, with a single poppet design, is used in suction pump lines to hold the prime. This full-flow valve features all brass parts and flat seat and disc construc- tion. Seats and discs are -~--- precision-machined to exac- ting standards and discs ere lapped to the seats for tight, positive sealing. Also equipped ~ with a strainer to screen out fuel line contaminants. Heavy- r duty hex at the valve top facilitates installation on the suction pipe without distorting the Valve body or damaging internal seat and disc. Model No. Outlet Weight A B A438-005 1 1/2" Female ' 3 lbs. 2 23/32" 4 7/16" NPT Material: Body: Brass, Seat: Brass, Disc: Brass, Screen: Brass, 8 mesh A439 Foot Valve, Double The A439 Foot Valve has the A438, but features a double Poppet the same proven features as poppet design for added pro- tection and increased service life. Model No. Outlet Weight' A B A439-005 1 1/2" Female 4 lbs. 2 23/32" 6 1/32" NPT I i I I A677 Foot Valve Extra~ctor Fitting Underpump Valves The A677 Foot Valve Extractor Fitting permits access to and easy removal of foot valves from the underground tank with little service interruption and no excavation. Features a composition crimp which seals against the side wall of the Cast iron body, and a sealing disc instead of the standard gasket. Lid is sealed to prevent the loss of prime. Requires the A5§0 Extractor Wrench to remove the A584 Pipe Cap, the extractor lid, and to lift the cage, foot valve and suction stub to the surface as a unit. B Replacement Assemblies: 490185:1 1/2" Cap and Cage Assembly. (Consists of cap, bolt, crimp, crimp ring, sealing disc and nut, and cage.) A560-001:1 1/2'Extractor Wrench Material: Body:.Cast Iron, Galvanized,.Lid: Brass, Cage: Brass, Crimp Ring: Cast Iron, Crimp: Corprene Disc: Corprene I I I i Top Seal Caps I A97 Tight Fill Cap I I ! IA99 Vapor Adapter Cap I I Tight Fill Products Emco Wheaton offers Top . Seal Tight Fill Caps designed to mate with fill adapters in various fill system config- urations. These caps supply "snap-tight" seal and can be padlocked for securitY. The A97 Top Seal Fill Cap is designed for use on all coaxial adapters and the A30 Adapter. Protects the adapter and prevents product contamin- ation. The A97 features an exclusive Self-aligning, toggle- action ·design for easy coup-. ling and removal. Toggle pins and cams are stainless steel, links are plated steel. Provides even compression on a Iow gwell compound gasket for ' long service life. Inclu,deS replaceable seals and padlocking capability. Model No. Material Seal Size Weigh! Works On A B .. Adapter A97-005 FRP Buna 4" Tight 1 lb. A30-014 2 5/8" 6 5/8" Fill 2 oz. A89, A96 Replacement Parts: Roll Pin (2 each): 562813, Cam (2 each): 562816, Link (2 each): 562818, Handle: 562819, Rivet: 562815 Seal: 563939 The A99Vapor Adapter Cap features a special cam ~ystem expressly designed.for use with the A76 adapter on the · vapor line portion of dual point fill systems. Made of corrosion resistant material and has an exclusive self-aligning toggle-action design. Same rugged design as the A97. Impregn'ated orange color to identify vapor return line. Will also fit any 4" cam and groove adapter. Model No, Material Seal· Size Weight ·Adapter · A B A99-002 FRP Buna 4" i lb. A76 2 1/2" Note: A99-003 Available with Chain Assembly. Replacement Parts: Roll Pin (2 each): 562813, Cam (2 each): 562817, Link (2 each): 562818 Handle 56819, Rivet: 562815, Seal: 563939 6 5/8,, I i I I I Tight Fill Pro'ducts. Top Seal Adapters Emco Wheaton Top Seal Adapters are designed to fit various 3" and 4" tank risers and accommodate standard and coaxial elbows for product drops. These' adapters 'are easy to install and provide secure se§ting on the riser. I I I I I A30 Tigl~t Fill Adapter The A30 Adapter is designed for use with conventional or dual point fill systems. Fea- tures recessed threads for easy installation and a buna gasket for positive seating on standard riser pipes, Use with the A97 Tigi~t Fill Cap and the Emco Wheaton F523 Elbow or equivalent. The A81 Adapter Wrench is recommended for installation. Model No, Size Material Weight A B A30-014 4" Female Hardcoat N PT X 4" Anodized Male Tight Aluminum Fill Replacement Parts: Buna Gasket 40962_8 13.5 lbs. 5 3/32" 3 31/32" ! Coaxial Vapor Recovery Adapters Emco Wheato~ Vapor Recov,o ery Adapters are expressly designed for standard coaxial fill systems and coaxial systems with self-seal.lng vapor lines. Features recessed ' threads for easy installation . and positive seating on riser pipes. Coaxial vapor recovery adapters are used with the A70 and A88 drop tubes and require A97 Fill Caps. The A81 Adapter Wrench is recom- mended for installation. Model No. Used With Material Size ·Weight A B A89-001 A88 3 lbs. 2 oz'. 5 3/32" 3 31/32" A96-001 A70, A9O Replacement Pa~ts: None Hard Coat 4" Female Anodized NPT X 4" Aluminum Male Tight. Fill Hard Coat 4" Female Anodized NPT X 4" Male Tight Fill 3 lbs. 11 oz. 5 3/32" 3 31/32" Service Station Equipment page 1 of 5 I . ' ...' "' I Valves and Fitting~ Manholes ' . I Vapor Recovery Vents NoZZles & Accessories Drop Tubes & Fill Connectors ~ · i . Gau~eS ' . I' Emergency Shutoff Valve---FIG 636 Series I Required °n undergr°und tank m°t°r fuelmg systems' The emergency shut-°ff valve °r "impact ~,~. Double Tapped Bushings--FIG 184 Series Used in pipe and tank fitting to reduce 'or adapt to a connection. Cast iron with NPT threads. The duplex bushing is used to connect 2" pipe to dual 1/2" or 3/8" lines. ExtractOr--FIG 560 Series Installed on the vent line of an underground storage tank. Extractor allows vent to be lines manifolded and also allows removal of float vent valve (Fig. 317) for repair or replacement. Various sizes available. CARB approved. I I I I Float Vent Valve--FIG 317 Series A main component of the ExtractorfFloat Vent Valve overfill prevention system. (Fig 5~60/317). Installed on a UST vent line. When filling a tank, the ball floats on the liquid and rises to the seat area on the pipe nipple. The level of the seat is set at the high ·level limit of the tank. Once seated, air flow becomes restricted which abruptly reduces the filling rate and warns the operator to stop filling the tank Extractor Pipe Cap--FIG 578 Series Used as a cover for the Extractor/Float Vent Valve overfill system. Installed on the riser pipe at grade level normally inside a manhole. I I Ball Valve (full port)--FIG 691 Full port ball valve used for liquid handling with manual open-close in quick quarter-turn handle operation. Threaded (NPT) connections. Valve can be operated in partial open position. Lockable with padlock. http://www.morbros.com/Service_Station.htm 2/11/2004 I I I I I' I I I Sump Cover & Spill Collector 4770 Caterpillar Road · Redding, California 96003 (916) 2414914 (916) 222-8015 FAX (916) 241-5820 I I - SC.3600.SCA-3 I SC.3600.0A0 SC-3600-TSC-1-2 SC-3600'T5C-1- I ' SC-3600-TSC. ! I SC-3600. TAO 5C-3600-T5C.2.2 SC-3600. TSC-2.1 5C-3600.T5C-2 SC- 36 00- TAO- I SC.3600- TAO-2 SC-3600-L S C-3 600- TA O SC-3600-TAO-1 SC-3600-TA0-2 SC-3600-WSC ' SC-3~00-SC.4 ---~C-3600-SC_4-2 5C-3600-5CA-3 5C-3600-T5C-1 5C-3600-T5C-1-1 5C-3600-TSC-1-2 SC-3600-TSC-2 5C-3500-TSC-2-1 5C-3600-TSC-2-2 5C-3601 -SS FG-4251-5 ' PC--4333-SRO £G-4333-5RC Turbine Cover (Not pictured) 1 Access Opening 2 Access Openings 3 Access Openings 4 Access Openings I Spill Co~lector 1 Spill Collector + 1 Access 1 Spil] CoEector + 2 Access 1 Spill Collector + 3 Access 2 Spill CoEector Openings +'1 CoEector 2 SpEl Collector Openings + i Collector + i Access 2 5pEI Collector Opon~gs + i Collector + 2 Access .2 SpEI Collectors Complete 2 SpiE CoIlectors Complete + I Access 2 SpEI Collectors Complet~ + 2 Access 'Light Weight Secondary Sump Shield (Not pictured) F173erglass Sump (Not pictured) Fiberglass Sump Reducer (Not pictured) Fiberglass Sump Reducer (Not pictured) ALL ACCESS OPENINGS WILL BE LOCKED DOWN AND SEAL~r~ UNLESS OTHERWISE REQUESTED. STANDARD BUNG CONFIGURATION, IN LINE OF TANK, SHALL BE 16' CENTER TO CENTER. SIDE T° SIDE ACCESS OPENINGS WILL BE i.. CEKIER TO CENTER. ANY DEVIATION MUST BE REQUESTED IN WRITING FOR QUOTES. ***FOR CONFIGURATION OTHER THAN PICTURED. FURNISH DRAWINGS AND MEASUREMENTS 3/8. Reinfomed Diamond Plate with special cam lock mech's, and Grade 8 Cad Plated Bolts with seals. "O" Ring 12 Ga. Rolled Steel Frame High Density Polyethylene Sump Shield #SC-3001-SS Nylon Collector INSTAl. IATION INSTRUCI'ION$ To set the e/evation for the §bez'glass sump, the optimum position shou3d be 8" be/ow Enished concrete or asphalt grade. This aI/ows a l"-overlap for stee/ Spill collector frame when it is e/evated 1 "above iinished concrete grade. 37Hs e/evation setting a/so posiMons, the'Hght weight high density poIyeth~ene sump shie/d, nurmber SC-3601-SS to the eight position for e/irninati~g water intrusion. Cut the 4" CE/pipe ztser to a length of 14 i/2" be3ow ~933shed concrete grade. (Not the 1" e/evated grade) /L~er all grades are set and tanRs are bacJ¢ Cd[ed to top of iiberglass sump, SpHI CoEector can be insta/[ed. Nov~ insta/I the Hght weight high density p°I]ethylene sump shie/d with the proper openings cut out. Then instaE the nylon spHI coIlector buc~ket, hand tighten against "0" z~ng, · if the SpHl Collector is used on the vapor aide instai[ vapor spHl-collector now. (Vapor spHI collector is different. It is 1" shoz~er on the 4" ziser, be sure to chec_R this). '~row the spEl collector Hd and frae'ne can be insta//ed. Using z cam locR mechanism to fasten the Hd to the frame-by '~'-tun33ng boIts, docRv~se unHl cams inter-Ioc3~ with dimples in frame, then tighten approxirnate/y one turn more to tighten doyen against sea/. (12)o this in a cross Hd pattern which ~ apply even pressure on sea/). ~nger the lid is proper/F in'staffed on the frame, H can now be posilioned over sump and' spEl coEector bucket. It may be to your advantage to leave off spHI coEector bucket "O"zing on this initia/ instaEaHon and after concrete is poured then remove Hd ,~nd instal/"0" zings to gna~ insta/]ation. Be sure when Ed and frarne are instaUed that 36"Hd is at least 1 "above ~mished concrete grade and that coEector bucketis 2" be/ow ilange in coEector. If these instructions are folloWed you should have an attractive and easy insta/Iation. SUMP COVER LID I~EMOVAL For ease of remora~ we have fuJTHshed.~ack.screws. Jrirst, tun~ a/I hold dow~ bolts (1/2 Hex) counter c[ock~se to stop.. Next, remove button head aEen screws (Do not d~scax~) inse~t "T" handle.lack screws in threaded hole (i£ "T" hand[es axe not available use 5/16" - 18 bolts) and raise Ed. Vv~en Ed is ~ree [rom coEecto£ bucket "0" zing use "T" handle to Eft Erom sump. To replace Ed simply Iower Ed over SpiIl collector buckets. Remove "T" hand[es and press Ed into place~ turn hex bolts docR~wise untiI.pressure is re~t, then in cross. Ed tightening paffen~, tighten bolts to draw Hd down against the sea/ evenIy. PIea~e z~.fJ~taJ~ tbe b~tfon head aJ~en $c~,s. _ I I I I I I I I I I I I I I N ew federal regulations require existing underground storage'tanks be upgraded to meet the new requirements for spllI and overtlow protection. In addition, ali new underground storage tank/nstallations must comply upon installation. PhE-flte Enterprises Introduces their NEW PhE-ttte sump cover sptlI coHector'unlt The Phil-tire sump COver and spill collector' system meets or exceeds all federal regulations. And, the unique design 'has been cng/nee_red to . provide maximum spill and overflow protection through the use of (up to two) spill collectors and two additional diamond plate lids, which seal and lock in the assembly., The unit mounts directly over the sump area for easy installation and' ,allows access to the dser cluster. The sump opening allows a full 36" diarneter of clear, unobstructed, area to facilitate the removal of the · oPtional lightweight sump shield and access to the sump area. The sump shield Virtually eliminates all surface water from entering the sump area and has been designed to align with the sump cover lid. The PhiI-tite unit'is availabIe in different con~gurati°ns- from bland top to as many as 4 openings in any combination. In addition, lid removaI is made easy with the spedal locking devices provided.. For more information on the Phil-rite' sump cover and spill collector, call our Redding. California manufacturing office today: '(916) 222-8015 PAT. NO. 4,696,330 and other patents applied for ~:;~.PRIH'rEo ~ RECYCt. ED P~PER I I SC-3600-TSC-2-1-12 ,- (MANWAY WITH 12"SIDECAR ACCESS) SUMP REDUCER FG-4933-SRDO (RECOMMENDED BY MANUFACTURER) SLEEVE IS WELDED TO OUTER FRAME ~lS SHOWN SC-3600-TSC-2 LID IS SHOWN HERE FOR REFERENCE. SIDECAR IS AVAILIBLE WITH ANY LID CONFIGURATION. ITEM 1 2 3 4 6 PART NO. DESCRIPTION SC-$600- TSC-2 (SHOWN FOR REFERENCE) SC-$613 13' ACCESS LID 5/16-18 X 3/8 LG. BUI~ON HEAD CAP SCREW SC-1501-S CAM LOCK (SMALL) AL-I350 13' ACCESS LID 'O' RING~ 85010-1 SLEEVE 1 1 $ 1 1 Phil-Tire Enterprises Technical Support (530) 223-74-00 107' I WA TER TITE SUMP SHIELD I .''(ASSEMBL I , . 2os~rcrlo~v view, .' '( ~ ITEM PART No. DESCRIPTION . REQ 'D. I 2 $ $ 6 FG-340HWTSS FG-3$OHWT~4 WTR-IO13 WTBC-llO# WTBC-1300 WTL.4000 W.4TERTITE SUMP SHIELD (RING & SHIELD) 1 AD~4PTER RING 1 REDUCER BOOT FOR BUCKET' . 2 II " BUCKET CL4MP 2. 13" BUCKET CL,4MP 2 L,4 TCIt 6 SEE FOLLOWING PAGES Phil-Tite Enterprises Technical.Support (530) 223- 7400 113 I I I I I I I M-1800 (MAIN ASSEMBLY) ITEM 1 2 3 '4 PART No. 1800 - FSK SC-1518B 1800L Sc. lSOl. s DESCRIPTION REQ'D. SKIRT · 1 SKIRT '0' RING 1 LID 1 C/d~l LOCK (SMALL) 3 Phil- Tite Enterprises Technical Support (530) 223-7400-- 45 I I I I I I I I I II M- 1800 DIAMOND PLATE A A OPEN CLOSED SKIRT . , a~c~toe a~ PLACES 20 1/8 (STANDARD) MA Y BE AL TERED TO SUIT VAIHOUS'BURIAL REQOYREMENTS !, ISECTIONA-A I ~ 4,4 Phil-Tire Enterprises Technical Support (530) 223-7400 I FG_4240_S_2 I F~~4251~S,~2 ra 4261 $ 2 Il' ' r WO PIE CE SUMPS I ~ 42 DIA. - ~- :- ~ 42 DIA. I F¢4~~J-S-2 F¢4251 I 42 DIA. 104 FG-4240-S-2 Phil-Tire Enterprises 40 NOTE: TWO PIECE SUMPS ARE PROVIDED FOR EASE OF PLUMBING. Technical Support (530) 223-7400 Vents ~0084 'Pressure VacuUm vent The Emco Wheaton A0084 is an internal pressure vacuum valve that restricts vapor escape during product drops. It meets all regulatory codes requiring the installation of pressure vacuum vents. The A0084-009 is UL listed. ' A0084-004 I 2" I 13-e6"H20 (0-0007-) I 0-8"H20 (0.50or_) 1.7 lb. 5" A0084-009 (Int'l) ~ 2" Clamp on I 13'86"H20 (8.00oz~) ~ 0.8"H70 (0.50o7-) 1.0 lb. 5" A0084-100 J2" J 2.00"H20.(1.14o7-)J 3.0"H~0 (I.88o7-) 1.7 lb. 5" A0084-101 ' J 2~' Clamp On J 2.00"H~0 (I.14o:) J 3.0"H~0 (I.88o7-) 1.7 lb. Viton~ is a registered trademark 'of DuPont Dow Elastomers. 8 9.5" 8.9" 9.5" 9.5" Material Body:. Aluminum . Seal: ' Viton® Cap: Polyethlehe I ssure Vacuum Vent ~ A0084 Ail Metal pre . ~ .... ~ The Emco Wheaton A0084 is an internal pressure vacuum valve that restricts vapor escape ~ ~ II during product drops, The body and cap are anodized aluminum for corrosion-free sem)ice. ,.: ii ~~8~ Model No. Inlet Pressure Setting Vacuum Setting Weight ~ ~' · ~- ~ -~ ~ ~ '~ A0084-015 ' 2" BSP 13.86"H~ (8.00o:) (I.88oz.) 2.0 lb. A0084-038 2" ' 3.00"H; (I.73o7-) (5.00o~.) 2.0 lb. A0084-103 2" Clamp On 3.00"H: (I.73o7_) (5.00oz_) 2.0 lb. 0.8" H 3.0" H 8.0" H 8.0" H I A0084-105 2" Clamp On' 2.00"H: (I.14o7-) 0.e"H (0.S0oz.) A0084-200 2" 2,00" H; (I.I 4oz..) 3.0" H (I.88oz.) A0084-201 2" Clamp On 2.00"H.' (I.14oz.) 3,0"H (I.88o7-) ' A0084-204 2" 13.86" I- (B.00oz.) 0.S';H 0 (0.50oz.) : A0084-209 2" Clamp On 13.86" H (8.00oz_) 0.8' H;0; (0.S0o7-) 2.0 lb. Material 2.0 lb. Body: Aluminum 2.0 lb. Seal: Viton® 2.0 lb. Cap: Aluminum 2.0 lb. A4103 Upward"' nt The Emco Wheaton A4103 Upward V Vent utilizes a straightLup "V" design to rapidly disperse vapors. Slip-on style Vent attaches to the pipe with three screws for easy I/-,- installation. Screen can be easily removed for cleaning. Designed in accordance with NFPA 30 and UL listed. · M°delN°: I Inl,e,t IMaterial I Weight I A I B A4103-002 I 1.5' &2"I Polyethylene I 0.7lbs.' I 5" I 5.9" . A4103-003 I 3" I Aluminum I 2.2lbs. I 6" I 5.2" :, I A0785 Downward MushrOom Vent The Emco Wheaton A0785 Downward Mushroom Vent is designed for downward venting of storage tanks. The 40 mesh brass screen can be easily removed for cleaning. The A0785 threads 'onto either 1.5 or 2.0 inch vent lines, Clear coated aluminum for corrosion-free service. Modal No. Inlet Material I Weight A0785-001 1.5" & 2" Aluminum 1.0 lbs. _ Female A0785~101 1.5" & 2" Female BSP Aluminum 1.0 lbs. EmcoWheaton Retail · 2300 Industrial Park Drive [] Wilson, NC 27893 ~ 252,243-0150 - 41 Overfill Prevention Valve I I Conventional Screw Together - with Hold-Down Cage Remote Fill Application ALI00 GUardian Overfill Prevention Valve Systems coaXial Stage I Vapor Recovery~ Self-Sealing A0585-003 Extractor Pipe C~p A0379-101 Hold-Down Cage Al I00 4" Drop Tube Optional Remote Fill Application C B 493785 Spring Loaded Self-Saling Vapor Collar' 3.25" Coaxial D~op Tube ' AIIO0 4" DrOp Tube I I Iqodel No. Al 100-010 A I 100-0545C Al 100-065 A 1100-066 A I 100-067 A I'100-085 A I 100-086 A I 100-087 Description Valve Only Dual ~ Screw Together w/Cage Coaxial Coaxial Coaxial Coaxial Self Sealing Coaxial Self Sealing Coaxial Self Sealing Upper Length A N/A 54.1" Lower Overall Length C 72,7" 72.7" 72.9" 72.9" ,72.9" L, .gth a N/A 109.8" 88.6" 100.6" 126.6" 88.6'~ 100.6" 126.6" N/A 163.9" 161.3" 173.3" 199.3" 161.5" 173.5" 199.5" Maximum Burial Depth N/A N/A 67.6" 63.3" 60.8" 67.6" 63.3" 60.8" Nominal Tank Diameter N/A N/A 96" 120" 144" 96" 120" 144" Weight 4.3 lbs. 26.0 lbs. 20.4 lbs. 22.8 lbs. 25.3 lbs. 20.9 lbs. 23.3 lbs. 25.8 lbs. All OPV systems listed above can be ordered as a package which includes an A0097-005 Tight Fill Cap and an A0089-001 or A0096-001 Tight Fill Adapter. To order, place a P at the end of the variant number. (Example: Al 100-085P) Custom lengths available: Please contact our customer service department. Lengths A and B are measured from the shut-off point (flapper).. Maximum burial depth assumes 95% shut-off and 6" clearance between top Of drop tube and inside bottom of containment manhole lid. · EmcoWheaton Retail · 2300 Industrial Park Drive. == Wilson, NC 27893 [] 252-243-0150 26 Overfill PreVention Valve AI 100 Guardian Overfill Prevention Valve Systems Stage I Vapor Recovery - . Dual Point Riveted · Dual Poini Screw Together .... -~ ~ 493734 Lr- ~' 493734 I I [-:--1 11 4" D~ Tube [~ // i Model No. Al 100-010 A 1100-055 AII00-056 Al 100-057 Al 100-058 A 1100-055S A 1100-056S Al 100-057S A 1100-058S Description Valve Only Dual Point Dual Point Dual Point Dual Point Dual Pt Screw Together Dual Pt Screw Together Dual Pt Screw Together Dual Pt ScrewTogether Upper Length N/A 77.1" 89.1" 89.1". 127. I" 77. I' 89.1" 89.1" 127.1" Lower A Length B N/A 88.6" 100.6" 126.6" 126.6" 91.8" 103.8" 129.8" 129.8" Overall Length C N/A 165.8" 189.8" 215.8" 253.8" 168.9" 192.9" 218.9" 256.9" Maximum Burial Depth · N/A 72.1" 81.3" 78.7" 116.7" 72. I" 81.3" 78.7" I 16.7" Nominal Tank Dia. N/A 96" 120" 144" ' 144" 96" 120" 144" 144" 'Weight 4.3 lbs. .19.2 lbs. 21.4 lbs. 24.8 lbs. 28. I lbs. 21.5 lbs. 23.7 lbs. 27,1 lbs. 30,4 lbs. All OPV systems listed above can be ordered as a package which includes an A0097-005 Tight Fill Cap and an A0030-014 Tight Fill Adapter. To order, place a P at the end of the variant number. (Example: AI 100-055P) Custom lengths available: Please contact our customer service department. Lengths A and 8 are measured from the shut-off point (flapper). Maximum burial depth' assumes 95% shut-off and 6" clearance between top of drop tube and inside bottom of containment manhole lid. EmcoWheaton Retail ~ 2300 Industrial Park'Drive · Wilson, NC 27893 · 252-243-0150 25 Overfill PreVention Valve' The GuardianAIlO0 ' Body: Aluminum" /,~: o. ver floats f. or proc~on ~ __ , , .e~.- i~; : ~,~ ~:~ auring instauafion, snipping floats: r~ur: ~'.. : ',f · ::~. ' and operation, ® "~,.: ~ ::~ Seals: V~ton ~i!:: : ~:: ii~:: .. ;~:~ :.. ¼:. '. Dip Stick Diver~ers :!~,,~ ~: , permit sdck gauging at ~ any t~mk level wi~out Specifications :~:. damage to internal parts. Weigh1:. 4.3 lbs. :i!:i:,:/ Diameter: 3.76" · :: Integra:ecl Body Design I I I · suitable for both dual point Length: 18.0" ~ ' ~ ~ and coaxial drop tubes .... · · valve for all applications. Shock ReJief Va~hm · .~rova,s i incorporated to reduce. line shock. Drain Bleed Valve hose drainage, reduces unnecessary delays. Spring loaded and includes soft seat for posit'rye seal. Verticzl Slide FIozt Design installafion. Aura Relatch prevents premature shut. off. CARB ~ ' Viton® O-Rings ULC ~ at base of valve seals Clrop City of New York tube tu wive to pro~t City of San Diego against (e.~kage. I I I I I I The Emco Wheaton Al 100 is a two s~age overfili Prevention valve for use in both dual point and coaxial drop tubes. The Al 100 is easily installed in a new or exisrJng drop tube assembly for economical compliance wi~ EPA regulations. . Unlike competitive items, the Al 100 fpatures an incer~al float design that eliminates any chance of the floats getting caught on tank wails or the riser pip~. This design also prevents float damage during installation, Stick gauging is never a problem due to the Emc° Wheaton designed Stick diverter and automatic spring loaded poppet.that retracl:s from the flow path when not in operation. The drain bleed valve located at the top of the Guardian reduces hose drain time, helping to eliminate unnecessary delivery delays. Viton® seals are used throughout the AIl00. The Al I00 is compatible with ~11 standard fuels. Special variants are available for most bulk chemical applications.' Viton® is a registered trademark of DuP°nt Dow Elastomers. I I 24- EmcoWheaton Retail · 2300'Industrial Park Drive · Wilson, NC 27893 '" 252-243-0150 /-- SUMP WALL (INSIDE) SPECIFICATIONS./NOT E~ [~ONDuIT PENETRATION IAPPROVED BY J THIS DRAWING AND ITS CONTENTS 'ARE THE PROPERTY I : J OF WESTERN FIBERGLASS, INC., AND MAY BE USED J ; . ~ ONLY WITH.WRITTEN PERMISSION. ~ USA AND INTERNATIONALDESIGN AND UTILITY PATENTS P 'ENDING. ALL RIGHTS RESERVED WESTERN FIBERGLASS, INC. 1555 COPPERHILL PARKWAY ,SANTA ROSA, CA ?5403 PH 707-523-2050 FX 707-523..2046 - WWW.WESTERNFG,COM IW b loA . SUMP WALL BACKING PLATE 2"X 3" BOOT PENETRATION CUT 4 1/2" HOLE I ~'""PIPING BOOT Bi'DER 97/98 · JAPPROVED By: I THIS DRAWING AND ITS CONTENTS ARE T}.tE PROPERTY f ' OF WESTERN FIBERGLASS, INC., AND MAY BE USED L~ ONLY WITH WiUTTEN PERMISSION. WESTERN FIBERGLASS, INC. PH 707-52~50 ~ 707-52~2046 - ~W.W~NFG.COM ~ R. LEWIS i 940001D ~c~, NTS ']~'~:., 7/97 s~ . 1 ,l' I I I I I I I I I I I INNOVATION TITEFLEX, the'proven innovator in Flexible Con- nector Technology, offers the widest range of products designed for compliance with all aspects of safety, corrosion resistance and fire resistance regulations in fOrce today. This guide has been prepared to provide information on all TITEFLEX flexible bonnectors offered for Underground Storage Tank Systems. TiTEFLEX' innovative efforts began with the highest pressure rated STAINLESS. STEEL BRAIDED TEFLON ® FLEX CONNECTORS. We then devel- oped the SWIVEL MALE PIPING FITTING, which greatly simplified both installation and servicing opera- tions for flex connectors at the impact valve beneath dispensers. An intensive research and development test program into corrosion resistance of flex connectors led to the introduction of SOIL SAFE®20 and SOIL SAFE®30 - series of flexible connectors. Notably, our SOIL SAFE 20 and SOIL SAFE 30 products fitted with swivel male pipes mated unsurpassed Corrosion resistance and long term corrosion warrantees with ease of installation. This proved to be a breakthrough for TITEFLEX, a boon to installers and a new benchmark of performance for cUStomers worldwide. Another TITEFLEX fa'st is FIRE SAFE TM, the all-metallic, fire resistant connector. The fifth generation flex connector, SOIL SAFE APC, with all plastic construction to eliminate corrosiOn, is yet another TITEFLEX innova- tion. The TITEFLEX family continues to grow with innovative'ideas and solutions that work. TiTEFLEX the true source, the only source that designs and manu- factUres all types of connectors, Teflon/stainless, all- metallic, and all-plastic designs. ADVANTAGES All TITEFLEX Connectors offer several advantages ' to the contractor and system designer: FLEXIBILITY-Flex connectors withstand flexing and movement without damage or failure, AND eliminate alignment problems. DURABILITY-The Teflon or Fire Safe innercore will riot break down With age or exposure.and the connector is unaffected by the various ethanol/methanol blends of today's fuels. EASY INsTALLATION-Flex connectors are the fastest and easiest way to mate components at either end of a pipe run. Thetight bend radius allows easy bends. Permanently-attached fittings tighten easy with a hex or pipe. wrench. Convenient lay-line assists in proper placement. END FITTINGS TITEFLEX offers all generations of flex connectors in a wide variety of sizes and length~. We also have the widest range of fittings: Male Pipe ........................................ Female,~ Pipe BSP Male.. .............. ? ....................... BSP Female Swivel Male Pipe ........................... Swivel BSP Male All fittings are available in any combination or con- figuration of assembly-See chart on this guide for the most popular connector part numbers, or call TITEFLEX for price, availability and technical helpi Telephone: 413-739-5631 .. FIVE GENERATIONS of flex connectors, backed by the TITEFLEX trademark, innovative design, quality and service! ShOuldn't you be specifying the TITE connection? Your source: TITEFLEX. STAINLESS STEEL BRAIDED TEFLON Flex Connectors T1TEFLEX, the world's largest manufactUrer of Teflon PTFE hose, Offers the highest pressure rated, UL Listed (Listing Number 18R8) flexible connector for underground tank systems. The connector meets and exceeds the recommended pressure ratings of UL sPecifications. The convoluted Teflon innercore is reinforced with Teflon-impregnated fiberglass and type 304 stainless, stol wire braid. End fittings are zinc plated carbon steel. Standard assemblies are available in three sizes: 1-1/2 inch, 2 inch and 3 inch with lengths up to 8 feet. zz zM OPW 233 SERIES EXTRACTOR FITTINGS OPW 233 Sedes Extractor Fittings thread into 4" NPT openings.on undercjround storage tanks. A 4" riser pipe threads into the top of the 233 for use in Stage I vapor recovery or to.access a ball float. The 233 Extractor Fittings have threaded single-outlet connections for attaching tank vent lines or multiple-outlets used to manifold tank vents or accommodate Stage II vapor retum lines from dispensersl Internal threads .. on the 233 are designed to install a ball float or test plug in the extractor. Features InclUde ~ Duraguard Coated Cast Iron Body.- Helps prevent rust and corrosion for long service life. e, ZA!2 Zinc/Alloy Cage Assembly - Eases installation and removal of ball float vent valves and test plugs. OPW 233" Precision Machined Threads - Helps prevent cross threading of the ball float or tank riser pipe. The OPW 233 Extractor Fittings are designed for use'with all OPW 30MV and 3" 53VML Ball Float Vent Valves that include an extractor cage(The OPW 233 does not include an extractor cage). The 233 extractor !ncorporates either single-outlet or multiple outlet threads. OPw 233V The OPW 233V Extractor Fittings are designed for use with all OPW 53V 2" Ball Float Vent Valves. (The OPW 233V includes an extractor cage). The 233V is a threaded single-outlet extrac, tor designed to connect vent lines to the underground tank. OPW.233VM The OPW 233VM Extractor Fittings are designed for use with all OPW 53V 2" Ball Float Vent Valves, (The OPW 233VM includes an extractor cage), The 233VM is a multiple- outlet extractor used to manifold tank vents or accommodate Stage II vapor return lines from dispensem. OPW 233VP Extractor Test Piug The OPW 233VP Extractor Fitting Test Plug is used on all OPW 233, 233V and 233VM Series Extractor Fittings The 233VP incorporates an o-dng above the threads (on the plug) to isolate the tank from the vent piping systems dudng a tank test. OPW 233VMP Extractor Test ,plUg The OPW 233VMP Extractor Fitting Test Plug is used with the OPW 161iVR Slide Sleeve Vapor Recovery Adaptor System, The 233VMP incorporates an o-ring below the threads - '(on the plug) to isolate the tank from the vent piping systems during a tank test. Ordering.,. ,Specifications Product No. Top Thread Outlet Thread . Bottom Thread Weight in. mm, in. mm. ' in. _ mm. lbs. kgs. 233-4430 (Tee)* 4" 'i!02. 3" '~. ~ 4" ..102 Ext. 14.06 6;39 233-4422 (Cross)* 4" .~102 2"x2" i~:lxSt' 4" .102Ext. 15.18 .6:90 233-4433 (Cross)* 4" i'~!.02:' 3" x 3" 76x76 4" 1i02 Ext.: 15.54 ~.'06 233-4432 (Cross)* 4" ',1{)2 3" X 2" 1'76x51.1~ 4" 'i;102 Ex't; 17.29 233VJA20 (Tee) 4" '1.02' 2" i"1'151 4" 1!~2 ExL 15.33 6.99 233V-4430(Tee)' 4" '10211 3" ' ,,176,' 4" /i02ExL 12.50 5.68 233VM-4422 (Cross) 4" ~i02.' 2" x 2" ' i$ix51 4" '!02 Ext. 16.62 ?55 233VM.4433 (Cross) 4" '102" .3" x 3" . 76x76 ' 4" 1!02 Ext. 16.98 ~.72 233VM-6045 (Cress) 4" "!02 3" x 2" ,'.~6x51 4 "i02 Ext.1 16.62 '8.51 233VM.604L (BSPP) 4" ~62: 3" x 2" 76x51 4" '102 Ext. 16.62 8.51' " * without cage assembly (TEE) (CROSS) R_eplacement Parts 'OPW 233V and 233VM Part No. Description H-8932 Cage SA 412-40 page 1 of 1 ,ill ~ Catalog:. 412-40 I The 412-40 Aluminum Pipe Cap is used for capping pipe in extractor valve assemblies. Features: · Includes gasket All meta1 construction Plated steel' crossbar I Size: 4" Weight (LBS_~.' 1:2 'l I I I I I I http://www.universalvalve.com/412-40.html 7/22/2002 Piping - Western Fiberglass, In, Page 1 of 2 II I I I I I I I I I I I I I I I ~' VVF~H°me I I ' MeetWF~ I I Petroleum Products ] I' '~'~L~Piping-C°'x~ 'l [~ Sump. SystemS I ~ · Storm~Water Filtration industrial Products Piping - CO- FLEXTM I SystemS J IOther Containment Products Fittings. Reducers, ETC. [Services ' - ~1 ~ Site & I Technical Drawings I~ Material Takeoffs > Liaison& . Jurisdictional Bodi_____~ Assistance in Preparation of agency. approvals I Warra aries ' [ I~ Warranties- IContacting WFG . ~ General I PIPING Co-FI. ex Ftexibte Doubte watt PiPing I 1/2" and 2" iD Options{ Removabte Conduit/R0ckGuard U,L, 971 Listed for Direct Bury E,R.A., U.L.C., I,P. and 5,I.P.C, Certified "Direct ConnecUon".TM or tradiUonat Swage FittinEs ~uiiy-] 18" Bend Radius (1 1/2" Co-Rex) 24" Bend Radius (2" Co-Rex) 75 PSI Primary and Secondary Compatibte with att current fue[. btends Smooth bore for higher product flow Easy instal[aUon Furry testabte Co-FlexTM, Double Wall/coaxial, piping from Western Fiberglass, Inc. represents the latest technology available in underground piping systems. Fully listed and certified by regulatory agencies worldwide, . Co-FlexTM Piping is easy to install, cost efficient and has the best warranty and service support in the industry. The unique "Direct Connection''*M fitting design requires no special tools or equipment to install or remOVe, using only a simple torque wrench for attaching connections. Available in diameters to suit any installation, U.L, U.L.C., ERA, I.P., S.I.P.C.. listed and certified, Co-FlexTM Piping Systems truly take flex piping into the next millennium. Fuel Oil Pipe (Single Wall) http://www.westernfg, com/piping.html Vent/Vapor Recovery/Remote Fil (Single Wall) 3/25/2002 Piping - Western Fiberglass, Inc~ Page 2 of 2 I I I I I ,Il i Information Order Technical . Publications & CD-RO._..~M ' Corporat"~~ Headquarters: 1555 Coppe~ill Parkway Santa Rosa, CA 95403 East Coast Factory: 7519 Ware NeCk Road Glourster, VA 23061 Telephone: Toll Free (USA only) 1-800-688-3375 - Voice 1-800-700-1188 - Fax International 1-707-523-2050 - Voice 1-707-523-2046 - Fax 1/2,, 3/4", & 1" I.D. Hand Swage Fittings Optional Removable Conduit/RockGuard Minimum Bend Radius 200+-PSI 2", 3, & 4" I.D. · Optional RemOVable Conduit/RockCmard "Direct ConneCtioa''m Fittings (Fully-Removable) "Semi-Flexible" to maintain slOg {Destination? ~. 1998, i999 © WESTERN FIBERGLASS, INC http://www.westemfg.com/piping.html 3/25/2002 I I I I I I. I WESTERN FIB~GLASS, INC. 1-800-688--3375 "CO-FLEX 2000'T~ COAXIAL (DOUBLE WALL) THERMOPLASTIC PIPING Summary The "Co-Flex 2000~' coaxial fuel transfer hose is to be installed for the purpose of product delivery and provides secondary containment for the product piping, in accordance with the manufacturer's,~on instructions. The"Co-Flex 2000" Double Wall Piping System shall contain envirOnmentally hazardous fluids that might leak from the product piping provide fluid communication and shall include COrrosion resistant fittings and coUPlings for connections within.' containment sumps located at the tanks and dispensing'points. The "Co-Flex 2000" piping system shall be manufactured/supplied by Western FiberglaSs, Inc. System Specifications 1.01 SYstem Suitability The "Co-Flex 2000" Piping sYStem shall: A~ Provide secure, secondarily contained fuel transfer between storage and dispensing devices with equal full pressure rating for both primary and secondary pipe sections. B. 'Be dire, ct buffed or removable installed' within a RockGard/Conduit system. C. ContEmany release of environmental contaminates from the product primary pipe, contained within the "Co-Flex 200tY' Syster~ D. Provide fittings, test points and COnnections aS reqUired to facilitate direct connection piping and monitoring of containment between product storage aud 1.02 Construction Specifications: A. Be, constructed with a smooth seamless inner wall that is a specialized Chemical and Permeation resistant thermoplastic with the outer layer being a flexible thermoplastic tie. . · B, The reinforcement is a synthetic Polyester fiber applied in braided phes, ~C. The hose cover is a smooth, seamless sheath of fuel ~istant material. D. Be constructed of materials that are not harmful to the environment E. Be suitable for chemicals, food products, petroleum products and blends including methanol, ethyl alcohol MTBE, ETBF. and additives. F. Hav~ life time warranty against corrosiva V .D ROOT Modular design meets current business and regulatory requirements, with expansion capabilities for future needs. Integrated solution for centralized, single- system site monitoring. Programmable leak test features, 2-line, 24-character-per-line liquid crystal display and 24-button keyboard step the operator through simple programming and operation functions. With its modular design, the TLS-350 lets you choose the exact set of complia~nce and fuel management features you need today. As regulatory requirements and your business needs change,'the flexible TLS-350 platform allows you to add new features tomorrow. A safe investment. A smart decision. Leading-Edge Leak Detection Technology The TLS-350 has defined the industry standard for tank monitoring systems with: advanced magnetostrictive probe .technologies offering 0.2 GPH monthly monitoring and 0.1 GPH volumetric tank testing; accurate, automatic electronic line leak detection; and, 4SITEAdvanced Technology Sensors and a complete line of standard leak sensors to monitor double-wall tanks, containment sumps, and wet and dry wells. Plus, for 24-hour stations and high-volume operations, Continuous Statistical Leak_Detection (CSLD), the most advanced leak detection technology available today, provides 24-hou r, automatic leak detection without tank ~i¢/~ shutdown. No lost business. No lost operating time. ~' · L~ading-Edge Business Managen~ent'Features The TLS-350 takes business management a step beyond normal'fuel inventory management. The SiteFax option provides auto-dial fax capability, letting you send up to 16 different reports to up to 8 separate fax ma- chines on a'Programmable schedule and fax alarm messages instantaneously. The Graphic Remote Display 'option lets the operator view all inventory, alarm and system status information without leaving.the counter or office unattended. The optional fuel manager software available for the TLS-350 allows you'to track average daily fuel usage, predict the days of remaining inventory, and improve delivery scheduling. By utilizing Remote ControlTM Veeder-Root's tank management software, all inventory management and environmental compliance can be easily centralized on a personal computer in one location. The use of these time and 'money saving options extend your investment in the TLS:350 beyond environmental compliance requirements, improving your· bottom line. System Capabilities ~ Continuous inventOry monitoring. I~ Fast, O. 1 GPH in-tank leak detection for up to 8 tanks. I~ CSLD option for continuous 24-hour leak detection. I~ Line leak detection. l~ 'SiteFax auto-dial fax capability. ~ Graphic Remote Display option. ~ 4SITE advanced technology Sensor compatibility. I.. Interstitial and piping sump leak sensing for up to 64 sensors. ~ Vapor and groundwater monitoring for up to 40 wells. ~ External inputs. ~' Relay outputs. I~ Programmable alarms. I~ Data communications. ~ All third-party tested. All proven in the field. Emergency Generator Applications ~. Selectable via programming. ~' One system handles mix of standard and emergency generator tanks.. I~ Records generator activity. ~ Complete inventory reports before and after generator operation. There's Profit Beyond Compliance. With Veeder-Root. Standard Models FORM NO. DESCRIPTION 847090-022 TLS-350 Monitoring Console with Integral Printer (includes Printer Communications Module) 847090-002 TLS-350 Monitoring ConsOle without Integral Printer TI.S.350 InterfaCe Modules The TLS-350 monitoring console contains three compartments in'which individual interface modules can be installed. Interface modules may be factory-installed in the console upon initial ordering, or ordered separately as spare mod- ules to expand an existing system. FORM NO. FACTORY- FORM, NO. · INSTALLED SPARE FEATURE COMPATIBILITY MODULES MODULES . DESCRIPTION (WHERE APPLICABLE) LOW-POWER COMPARTMENT (Limit eight per console, unless otherWise noted.) 329356-002 847490-104 - Four-Input Probe interface Module Series 8473 0.2 GPH Magnetostrictive Probe (Maximum two per console. Includes terminal Series 8473 0.1 GPH Uagnetostrictive Probe connector for one ground temperature thermistor for the volumetric line leak detector.) 329358-001 847490-102 Eight-Input Interstitial/Liquid Sensor Interface Module Series 7943 Interstitial Sensor ior Fiberglass Tanks and Interstitial Sensor for Steel Tanks Series 7943 Piping Sum~) Sensor ' Series 7943 Hydrostatic Sensor 329357-~)01 847490-101 Five-input Vapor Sensor Interface Module Series 7943 Vapor Sensor 329399-001 847490-103 Five-Input Groundwater Sensor Module 4SrrE Series 7943 Groundwater Sensor 329956-001 847490-105 Eight-Input Type A Sensor Interface Module 4SITE Series 7943 Discriminating Interstitial Sensor 329950-001 847490-106 Six-Input Type B Sensor Interface Module 4sl~ Sedes 7943 Discriminating Dispenser 330373-001 847490-109 Six-input Pressurized Une Leak Interlace Module Series 8484 Pressurized Une Leak Detection System (One per console) Requires TLS-350 Version 7.0 or hig. her software HIGH-POWER/COMPARTMENT (Limit eight per console, unless otherwise noted.) 329359-001 847490-200 Four-Relay Output Interface Module 32936~-001 847490-201 Two-Input/Two- Relay Output Interface Module 323398-001 847490-202 One-Input Line Volumetric Leak Interface Module Requires Volumetric Line Leak Detector Kit No. 847590-001 329999-00i . 847490-204 Pump Sense Inteflace Module Accepts input from up to eight pump controls. 330374-001 847490-207 Three-Output Pressurized Line Leak Controller Series 8484 Pressurized Line Leak Detection System Interface Module Requires TLS-350 Version 7.0 or higher software. (Maximum two per console) COMMUNICATIONS COMPARTMENT (Limit three per console, unless otherwise noted,)* 330149-001 847490-305 SiteFax Interface Module Allows hookup to most remote facsimile, (Maximum three* per console.) modem or teletype equipment. Requires TLS- 350 Version 3.0 or higher software. 330148-001 847490-303 RS-232 Interface Module with Auxiliary Port Pr~)vides two 25-pin D-connectors for data (Maximum one per console.) .transmission to P.O.S. terminal, printing device, or computer. 329362-001 847490-301 RS-232 Interface Module Provides a 25-pin D-connector for data transmission (Maximum three* per console.) to P.O.S. terminal, printing device, or computer. 329957-001 847490-302 ' Remote Display Interface Module Veeder-Root Remote Display. (Maximum one per console.) 330000-001 847490-304 Remote Pdnter Interface Module Provides a 25-pin D-connector for data (Maximum three* per console.) transmission to a remote serial printer. *Maximum two per console, if console is equipped w/th an integral printer. -- Mag I and Mag 2 probes with O. 1 GPH and 0.2 GPH Leak Detection Capability, respectively Highly accurate, trouble-free inventory control and in-tank leak testing in gasolines, diesel and other approved fluids. Magnetostrictive probes are approved for aboveground storage tank applications. I I I I I · Pressurized Line Leak Detection System i Pedorms 0.1 GPH precision and 3.0 GPH testing at full Pump pressure. Reduces installation costs by installing' in the leak detector port. No need to ibreak product lines. I I I High Capacity Volumet- ric Line Leak Detector Designed for demanding and high- capacity piping applications. Performs 3 gph, 0.2 gph, and 0.1 gph automatic line leak tests. Float. SwitchType Intersti- tial Sensors for Fiberglass Tanks and for Steel Tanks Simple, reliable float-switch sensors detect the presehce of any liquid in ~he annulus of double-wall tanks. Piping I'~ I Sump ~ Sensor Float-switch sensor detects the presence of any liquid i'n the sump of double-wall piping systems. .Hydrostatic Sensors · Detect fluid level changes in brine-filled reservoirs or interstitial spaces of double-wall tanks. · '. "? ::~i Overfill Alarm and Alarm Acknowledgement Switch Provides early warning o!' potential UST overfills via an alarm relay in the TLS-350 console. Vapor Sensor Provides hydrocarbon vapor detection in dry monitoring wells, Adjustable vapor alarm threshold allows for acceptable existing vapor levels, VEEDER-ROOT Environmental Products The Leader in Tank Monitoring Technology Graphic Remote Display Remote viewing of TLS-350 monitoring system reports and data,· and remote activation of tank and line leak tests. SiteFax Module Programmable auto-dial fax capabilit!~ from the TLS-350 directly to a fax machine anytime, day or night." Remote ControiTM The only WindowsTM based . communication software for managing inventory and compliance information on Veeder-Root TLS consoles from any location no matter how remote. ' TLS.PC Programmable auto-dial fax capability Reduce user training and simplify daily compliance and business management with new TLS-PC software providing Graphical User interface to TLS system from back office PC. 125 Powder Forest Drive,.Post Office Box 2003, Simsbury, CT 06070-2003 TEL: (860) 651-2700, FAX: (860) 651-2719 TECH sUPPORT: (860) 651-2753 BRAZIl_: Sac PauJo · CANADA: Missi~sauga, Ontari~ · ENGLAND: Richmond Surrey · FRANCE: Au~nay-Sous-Bois ,, GERMANY: Aldingen · SINGAPORE: Singapore ?~ipteo' 13303 P./N 577013-268 AVR11 ~n 96 Operating Temperature Range 32°F to 118°F (o°C to 45°c) · Storage Temperature ·Range 15°F to- 118°F (10°C to 45°C) ~., 1, 1 V. I,P.S. i KNOCKOUTS (TOP AND BOTTOM) TO POWER TO INTRINSICALLY AREA SAFE AREA 193/4" BO'i'rOM VIEW I , i TLS~350 with Continuous Statistical Leak Detection (CSLD) --Automatic 24-hour 0.2 GPH monthly monitoring compliance, up-to-the-minute leak test results and fewer false alarms without shutting down your tanks. For 24-hour stations, convenience stores and other high- volume operations, this means no lost revenue or lost operating time--and greater profits! The TLS-350 With CSLD automatically collects data during idle times that occur normally during business hours. You don't have to sbhedule test times, and there's no operator involvement once the system is up and running! CSLD uses this information to form a highly accurate leak . detection database and applies sophisticated statistical analysis techniques to constantly evaluate the database. Invalid data are discarded and leak tests are performed using only the highest-quality information in the current always current. Test results are provided automatically every 24 hours, and up-to-the- minute leak test results are available at any time; Leak test results are accurate, and the chance of false alarms is greatly reduced with CSLD since only the best data are used. Plus, because leak test data are collected continuously and updated frequently, the response .time to detect leaks is shorter than that of scheduled static · leak tests. Third-party testing of the TLS-350 With CSLD showed a 99% probability of detection and less than a 0.1% chance of false alarm! That far exceeds the U.S.E.P.A. perfor- mance standards for monthly monitoring. database. In fact, a new leak test is performed every time- new data from an idle period are added, so leak test results are CSLD Software Enhancement Module · FORM NO. DESCRIPTION 330160-002 Continuous Statistical Leak Detection Software Enhancement Module Note: CSLD upgrade kits for existing TLS-350 Systems are available. Consult your nearest Veeder-Root sales representative. MAG ! probe required for each tank. I I I I I I I II- ~ l_ow cost solution for total information · management · Float ·determine presence of fluid, Switches and trigger alarms at Iow'level and high level "trip" points. · Conductive elaStomer differentiates between hydrocarbons and other liquids, and alarms when hydrocarbon is detected at any POint on the sensor. · Accurate, reliable and reusable even after exposure to heavy concentrations of hydrocarbons. · Long-life, durable construction. II Veeder-Root's Discriminating Dispenser Pan and Contain- ment Sump Sensors quickly and accurately detect the presence of hydrocarbons or fluids, and differentiate be- tween the two, in their respective locations. Alarm conditions - Fuel, Liquid Warning, High Liquid Alarm, Sensor Out - detected by either sensor are indicated by. an audible alarm, a displayed message, and a printed mes- sage on the TLS-350R, TLS-350, TLS-300/, or TLS-300C. They are also recorded as part of the Alarm History Report. The housing is constructed of polyester; the sensing element is a combination of conductive elastomer and float-switch technologies. The Sensors can be reused after an alarm condition is sensed, without degradation to the. sensing materials. Remove and clean the sensor, then reinstall for the same reliable sensing as when it was new. The Discriminating Dispenser Pan and Containment Sump Sensors are easily installed using Veeder-Root's Universal Sensor Mounting Kit. The Dispenser Pan and Containment Sump Sensors are warranted to be free from material defects for a period of one year from the date of installation or 15 months from the date of invoice. Detection Capabilities · SensorAlarm Conditions: · Fuel at any height on the sensor even when floating on other liquid, triggers a Fuel Alarm. · Liquid Warning is triggered when liquid reaches 1.0" high on both Dispenser Pan and Contain- ment Sump Sensors. ' · High Liquid Alarm is triggered when liquid reaches 8.0" on Dispenser Pan Sensor or 10" on Containment Sump Sensors. · Sensor'should be tested in liquid at least once a year or as required by local codes. Operating Capabi#'ties · Operating Temperature Range: - O°C to +70°C. · Storage TemPerature Range: - 40°C to +70°C. · Cable Length: 6 feet. · Dispenser Pan Sensor Dimensions: 11.53" high, 2.13" diameter.. · Containment Sump Sensor Dimensions: 22. 03" high, 2.13" diameter. · Withstand removal and replacement from sensing environment without sensor damage. - ! FORM NO. 794380-322 I . 794380-352 · 330020-021 ' I Dual. Float Disc~'~minat i The Series 794~ Dual-Float Discrim r Di~ TLS-350R Consoles* TLS-350 Consoles* I TLS-300i Consoles I Series 8482· Series 8470 Series 8485 · interstitial Sensor Interface Module No. 847490-102, required Discriminating Dispens~ I OPTIONAL CONTAINMENT SUMP; TYPICAL DISPENS; SENSOR INSTALLATION~,. . CONNECTOR PUMP I I . '"".",:,.0;. I CONTAINMENT SUMP AND DISPENSER PAN SENSORS DIMENSIONS DESCRIPTION Discriminating Dispenser Pan Sensor . Discriminating Containment Sump Sensor Universal Sensor Mounting Kit Dual. Float D~scHminat~7 Dispense~ Pan and Conf:aJnmen~ Sump Senso~ Cons~e Com'~afdM]~y The Series 7943 Dual-Float Discriminating Dispenser Pan and Containment Sump Sensors are compatible with the following consoles: TLS-300C Consoles Series 8485 *interstitial Sensor Interface Module, Form No. 847490-102, required for Dual-Float Discriminating Dispenser Pan and Containment Sump Sensors. 11 ill I TYPICAL DISPENSER PAN SENSOR INSTALLATICN TYPICAL DISPENSER PAN INSTALLATION IN A DISPENSER CONTAINMENT SUMP. PRODUCT. . LINE DISPENSER SUM CABLE U-CHANNEL EXTENSION BRACKET SENSOR · VEEDER-ROOT Environmental Products The Leader'in Tank Monito~ng Technolcgy 125 Powder Forest Drive', Post Office Box 2003, Simsbury, CT 06070-2003 TEL: (660) 651-2700, FAX: (660) 651-2719 TECH SUPPORT: (860) 651-2753 BRAZIL: Sao Paulo · CANADA: Mississauga, Ontario * ENGLAND: Richmond Surrey .. FRANCE: Auinay;Sous-Boi.~ · GERMANY: AIdingen · SINGAPORE: Singapore ~r~ntee, I I · Positive alarm indication of any liquid in .double-wall steel tanks. I · System indicators pinpoint alarm location. · Simple to install. ' I· Two-wire connection to system monitor. .I · Fast action helps prevent serious Safety and environmental problems. I I The Veeder-Root Interstitial Sensor for use in Steel Tanks detects the presence of liquid in the interstitial space of a double-wall steel tank. Liquid in the annu- lus could mean a'dangerous leak. When liquid is de- tected, the sensor sends an alarm signal to a TLS- 350R, TLS-350, ILS-350, TLS-300i or TLS-300C. monitor. The monitor's visual and audible built-in .alarm indicators immediately tell you where the prob- lem is, so you can quickly take action to help prevent serious safety and environmental problems. The TLS-350R, TLS-350, ILS-350, TLS-300i, TLS- 300C, TLS-250i and ILS-250 systems feature internal alarm relays that can also trigg(~r On-site alarms for even greater waming capability. The TLS-350R, TLS-350, TLS-300i and TLS-300C alarm signals from the sensor triggers a report showing the time and the location of the alarm condition. ThiS informa- tion is stored in the system's alarm history and can be retrieved through the monitor's integral printer or remotely through its data communications interface. The Veeder-Root Interstitial Sensor for steel Tanks can be used in the annulus of steel tanks with a sensor riser pipe of 1.5" I.D. or greater. Only two wires are required to connect the sensor to a'TLS or ILS system. Detection Capabilities' I~ The presence of any liquid in the tank's interstitial space triggers a Fuel Alarm. Operating Capabilities ~' Operating Temperature Range: -20°C to + 70~ C' (Hydrocarbons); 0©c to 70°C (non-freezing Water). ~ Storage Temperature Range: -40° C to +75~ C. I~ Available Cable Lengths~ 16 or 30 feet. I~ Dimensions: 2.5" high, 1.50" dia. Standard Components QTY DESCRIPTION 1 Interstitial Steel Tank Sensor '2 Watertight Cord Grips S~andard Models FORM i~O. ! · 794390-~20 , Inter: . 794390-z~60 ' Inter~ J ~terstiti; ~1 steel "he Series 7943 Into TLS-350R* TLS-350* ILS-350'* I Series 8482 I Series 8470 I rios 8450 NOTE: An Interstitial Set, rface Module, Ji~ e of the In ' NOTE: A Two-Wire Modt 7Uired for use h Fiberglas~ TYPICAL INSTALLATION ' ' MANHOLE * ' ~ ~ 1 i~1/2 INCH NPT THDS. ~ I I ~ D ~ (16 CUBIC INCH u I II I X ~ FORM NO. DESCRIPTION " 794390-420 Interstitial Steel Tank Sensor with 16' Cable 794390-460 Interstitial Steel Tank sensor with 30' Cable Accessories FORM NO. DESCRIPTION 312020-928 Interstitial Sensor Riser Cap and Adaptor Kit 2" interstitial steel Tank Sensor. Console Capability The Series 7943 Interstitial Steel Tank Sensor is compatible with the following consoles: TLS-300i TLS-3OOC Series 8450 Series 8485 series 8485 * NOTE: An Interstitial Sensor Interface Module is required for use of the Interstitial Fiberglass Tank Sensor with the TLS-350 Console. ** NOTE: A Two-Wire Module is reqUired for use of the Interstitial Fiberglass Tank Sensor with the ILS-350 Console. SWITCH DIMENSIONS LEADER CABLE '1' 2.10'~ NPT VEEDER-ROOT Environmental ProduCts The L'eader in Tank Monitoring Technology 125 Powder Forest Drive, Post Office Box 2003, Simsbury, CT 06070-2003 TEL: (860) 651-2700, FAX: (860) 651-2719 TECH SUPPORT: (860) 651-2753 BRAZIL: Sao Paulo · CANADA: Mississauga, Ontario · ENGLAND: Richmond Surrey · FRANCE: Aulnay-Sous-Bois ,, GERMANY: Aldingen · SINGAPORE: Sihgapore I I I '1 I I I I I I I I I I I MAG 1 MAG 2 · H/g~/y acaura~ Magne- tos~ffcffv~ measu]'sment technology ?,lA G 2(0.2 GPH) aYs/Jabte ~e~i~ffed t~ exceed s~anda;ds for O, ~ GFH Vo/umeirfc Tank Tight- ness Tesffng ',vit~ TLS-350 and TLS- ' 350R with CSLD for conffnuous statistical ~ MAG 2 probe thir~-pa~y ca.filed to exceed U.S. E.P.A. pedormance standards ~or 0,2 GPH Automatic Tank Gauging ~ Compatible with gas~fines, d~eset and other approved fluids ~ Water measurement .capability ~ 2" and 4" Float Kits available Seri&s 8473 MAG 1 Probe The MAG 1 probe provides highly accurate, trouble-free performance in gasolines, diesel and a wide vadety of approved fluids. Its magnetostrictive technology and five- point temperature sensing make it capable of extremely. accurate inventory control and in-tank leak testing. The MAG 1 probe has been third-party tested and certified to perform far better than the U.S.E.P.A. standards for both 0.1 GPH volumetric tank tightness testing and 0.2 GPH automatic tank gauging. See the summary of leak test performance on back or call us for a copy of the complete test results. Serfes 8473 MAG 2 Prcbe The MAG 2 probe provides the same reliable inventory control features and fluid compatibility as the MAG 1 probe, but offers 0.2 GPH leak detection at a lower cost. It offers MAG probe performance with 0.2 GPH monthly monitoring capability. The MAG 2 probe has also been third-party tested and certified to exceed U.S, E.P.A. standards for 0.2 G.P.H automatic tank gauging. See the summary of leak test performance on back or call us for a,copy of the complete test results. MA G I Probe and the TL~.-$~O ;'//i'~ CtLD ~ Leak detection without shutting dcwn your tanks/ CSLD, Continuous Statistical Leak Detection, is a new~ advanced tank testing technology that makes full use of the TLS-350 and TLS-350R's in4ank monitoring capa- bilities. CSLD eliminates the need tor tank shutdown to perform a leak test -- no lost business, no lost operating time! The TLS-350 and TLS-350R equipped with CSLD use the MAG 1 probe to continuously monitor fuel height and temperature information to detect idle times in the tank. During each idle time, data are collected and combined with information from other idle periods to form a highly accurate leak detection database. Sophisticated statisti- cal analysis techniques in CSLD constantly evaluate the database to discard invalid data and perform leak tests based on only high-quality information in the Current database. In fact, a new leak test is performed every time new data from an idle pedod is added. It's the next generation in leak detection'technology made possible, in part, by the accuracy of the MAG 1 Probe! Approved for Aboveground Tank Applications Veeder-Root Magnetostrictive Probes are approved for use in aboveground storage tanks to monitor fuel inven- tory. An AST Installation Kit (Form Number 312020-984) is required for these applications and is available from . Veeder-Root.or your authorized Veeder-Root distributor. I i I I I I MAG 1 PROBE FORM N0? I' TANKI.D.** 847390-101 4' 847390-102, 5' 847390-103 5'4" · 847390-104 6' 847390-105 7' 847390-106 7'6" 847390-107 8' 847390-108 9' 847390-109 10' 847390-110 10'6" 847390-111 11' 847390:112 12' 847390-113 2.0M 847390-114 2.5M 847390-116 2.667M 847390-115 3.0M MAG 2 PROBE FORM NO.* TANKI.D.** 847390-201 4' 847390-202 5' 847390-203 5'4" 847390-204 6' 847390-205 7' 847390-206 7'6" 847390-207 8' 847390-208 -9' 847390-209 10' 847390-210 10'6" 847390-211 11' 847390-212 12' 847390-213 2.0M 847390-214 2.5M 847390-216 2.667M 847390-215 ~3.0M Float kits for the specific fuel application must be ordered separately. Kits are available for 4" and 2" floats. See the Veeder-Root Price List for availability. ** Tank I.D. equals the "A" (probe Length) dimension on the drawing to right of the 'chart. Probe length (A) must · equal Tank I.D. PROBE TEST TYPE P(D) P(FA) TEST TIME MAG 1 0.1 GPH 99% 1% 3 Hours MAG 1 0.2 GPH 99% <.1% 2 Hours MAG lw/CSLD 0.2 GPH 99% <.1% Continuous MAG 2 0.2 GPH 99% <.1% 2 Hours A Magnetostrictive probe C°nsoie Cornpatibiify PROBE TLS-350R* TLS-350* TLS-300 TLS-3001 TLS-300C TLS-250 TLS-250i MAG 1 · · .... . · MAG 2 ....... * A Four-Input Probe Interface Module is required for use of magnetostrictive probes with the TLS-350R or TLS-350 system. I I I- ~¢ TLS-350R and TLS-350 systems equipped with the CSLD Software Enhancement are not compatible with 0.2 GPH Mag 2probes. CSLD requires O. 1 GPH Mag I probes. VEEDER-ROOT Environmental Products The Leader in Tank Monitoring Technology 125 Powder Forest Drive, Post Office Box 2003, simsbury, CT 06070-2003 TEL; (860) 651-2700, FAX: (860) 651-2719 TECH SUPPORT: (860) 651-2753 BRAZIL: Sao Paulo · CANADA: Mississauga, Ontario · ENGLAND: Richmond Surrey ° FRANCE: Aulnay-S0us-Bois · GERMANY: Aldingen o SINGAPORE: Singapore ~¢n~eo' WVRg g7 129,45 P/N 577013-041 O~.~. I I I I I I I I I I · Audible horn and flashing light provide an early warning of potential tank bulk delivery overfills. · Wired to one of the built-in alarm relays in a TLS-300, TLS-300i, TLS-250 or TLS-250i System or to an I/0 Combination Module or · a Four-Relay Output Module in the TLS-350 or TLS-350R. · Programmable overfill alarm limits can be set for each tank at a TLS System location. · Built-in timer lets you adjust length of time that the audible alarm will stay on from. ~'0 to 60 seconds. · Adjust noise level from 78 to 103 dB (at 10 feet), · Optional alarm acknowledgment switch. is available for locations where driver intervention is required by local codes. Audible and Visual Warnings of Potential Overfills Veeder-Root's TLS Overfill Alarm provides an early warning of potential tank bulk delivery overfills as required by the Federal regulations governing underground storage tanks. Wired to an alarm relay in a TLS-350R, TLS-350, 'TLS-300, TLS-300i, TLS-250 or TLS-250i System, the alarm relay activates the TLS oVerfill alarm horn and light when a potential overfill is detected. All TLS systems have programmable overfill alarm limits that can be set. for each tank at a location. An Optional Alarm Acknowledgement Switch is also available for locations where driver intervention is required by local codes. When the driver presses the acknowledgement button, the overfill alarm shuts off and the alarm acknowledgement light illuminates. This light will. stay on until the TLS prints an inventory increase report. SPECIFICATIONS General · Enclosure: Painted Steel; NEMA 4; 1/2" conduit connector at bottom of alarm and at left side of acknowledgement switch. · Operating Temperature Range: -40°. to +150° F. · Supply Voltage: 120'VAC, 50/60 Hz. Alarm Unit · Actuation: From TLS alarm contact. · Audible Alarm: · Output: Adjustable 'Time On" from 0 to 60 seconds. · VisualAlarm: · Lamp Rating 25 watt., 120 VAC. · Lens: Red Polycarbonate. · Flashing Rate: 75 per minute. · Dimensions: 11" long, 7" wide, 4" deep. Alarm Acknowledgement Switch · Function: Turns off alarm unit whlIe actuating acknowledgement lamp. · Acknowledgement Lamp: 120 VAC. Amber lens. · Dimensions: 7" long, 3" deep. Standard Models ~*~ " ~ FORM NO. DESCRIPTION 790091-001 Overfill Alarm 790095-001 Alarm Acknowledgement'Switch .© I I I ,I I I I Console Compatibility TLS-350R* TLS.350* I TLS-300 I TLS-300i TLS-250 TLS-250i Series 8482' Series 8470 Series 8485 Series 8485 Series 7841 . Series 7941 *NOTE: An I/0 Combination Module (Form No. 329360-001) or a Four-Relay Output Module (Form No. 329359-001) is required for use of the Overfill Alarm and Alarm Acknowledgement Switch with the TLS-350 or TLS-350R system. 1/2" Conduit 50.8 mm Connector DIMENSIONS Overfill Alarm 6.000" ~ 152.4 mm3 0 0 0.313~' 4 Holes 10.750" 273.1 mm Bottom View Front View without Door in Place 10.310" 261.9 mm 4.000' 101.6 mm Side View I I I I I 25.4 mm Alarm Acknowledgement Switch 6.3HY' 15O.3 mm 1 6.75O" I I BottOm View Front View without Door in Place VEEDER-ROOT Environmental Products The Leader in Tank Monitoring Technology Side View · 125 Powder ForeSt Drive, Post Office Box 2003, Simsbury, CT 06070-2003 TEL: (203) 651-2700, FAX: (203) 651-2719 TECH SUPPORT: (203) 651-2753 BRAZIL: Sao Paulo · CANADA: Mississauga, Ontario · ENGLAND: Richmond Surrey · FRANCE: Rungis Cedex · GERMANY: Neuhausen/Filder 12848 replaces 12594 AR8 in 94 U.S.A. Bulletin No. C331S November 1, 1997 Two-Piece Fittings I I I I I I PRODUCT smith Fiberglass Products offers secondary con- tainment piping systems with two-piece fittings that meet EPA requirements and help protect the environ: ment by containing po~sible fluid leaks in case of damage to the system. Secondary containment piping systems are avail- able in 3"-16" sizes. Manufactured of filament wound fiberglass reinforced epoxy or vinyl ester resin, the pipe is corrosion resistant and lightweight. The secOndary containment system is designed for use with RED THREAD® II, GREEN THREAD®, POLY THREAD® and CHEM THREAD® primary (product) pipe. Primary piping can be centered in the containment piping by using centralizers as needed. The-secondary containment piping system con- sists of the next larger pipe size (as a minimum) and special two-piece fittings. The size of the contain- ment pipe may be dic- tated by the leak-detec-. tion method used.' The standard Secondary pipe II, a - containment is RED THREAD fil- ament wound epoxy resin pipe. Other types of containment pipe are available on special order; ./.however,'the joint fit for standard containment fit- tings must be checked for the various types of pipe. Fittings are manufactured with vinyl ester resin and randomlY oriented glass fibers. Fitting manufactur- ing process is by either the compression molding process, or the contact molding process. Contact molding includes spray-up and/or hand lay-up process. Specific primary, or product, piping may be select. ed to meet your particular temperature, chemical, and pressure requirements. Depending on size and type of product, the pipe can withstand pressures to 450 psig and temperatures to 225° F. Refer to Manual No. C3300 and associated Product Data bulletins for Your primary pipe selection. The containment systems can be pre~ssure.,teste,d and COntinuously monitored. · Refer to,Manu?i' No. F6015, Installation Data for Two-piece SecondarY Containment Pipe & Fittings, for installati~h instrUctions. . Years of experience have proven that fiberglass pipe from Smith Fiberglass Products will outlast pipe made of traditional materials. The service life of fiberglass pipe is far gre~ter than that of pipe made from protected steel, copper, black iron, and even stainless steel. The advantages of lightweight fiberglass piping are even greater when installing secondary contain- SMITH FIBERGLASS PRODUCTS INC. · A S(JBSIDIARY OF A. O. SMITH CORPORATION 2700 W. 65TH ST., LII-I'LE ROCK, AR 72209-8592 · 501-568-40!0 · FAX 501-568-4465 I I I I I I. I I I I I I Secondary Contain nt Product Data merit systems. Very little equipment is required, and the ease of installation results in material handling and installation cost savings. Fn'FINGS A complete range of primary fittings is manufac- tured with the same temperature and pressure capa- bilities as the pipe. For containment systems, easy to use two-piece fittings constructed of vinyl ester resin and fiberglass are available. When c0.nnecting containment pipe and fittings, plain ends of the containment pipe are machined or thoroughly sanded to accept the two-piece contain- ment' fitting. Containment pipe must be positioned over the primary piping before assembly and bond- ing of the primary pipe system. The size of the con- tainment fittings may dictate the minimum center- line dimensions for the primary piping. Upon completion Of a successful primary pipe test procedure, the secondary containment fittings may be installed. The system-matching adhesive is applied to all bonding surfaces, and the fitting halves are then joined and bonded. Two-piece secondary containment fittings avail- able from Smith Fiberglass Products are assembled us- ing threaded inserts and hex-head bolts supplied with the fittings, along with Smith Fiberglass Products' adhesive and filler. CUSTOM DESIGN Smith Fiberglass Products can help you in solving secondary containment piping design problems. ' Smith Fiberglass Products also has experience in de- signing and installing double-wall secondary con- tainment systems 18" diameter and larger. Contact your Smith Fiberglass Products district sales manager for additional information. INSTALLATION Refer to Smith Fiberglass ~oducts's Manua] No. F6015 for installation instructions. Fitting Component Use 45° elbow 90° elbow tee coupling lateral concentric reducer termination assembly anchor assembly centralizer contain primary 45' elbow contain pnmary 90' elbow contain prImary tee contain primary coupling contain primary lateral contain primary concentric reducer terminate containment on primary pipe 'anchor primary to containment pipe support primary pipe in containment ~ .Secondary Contain~nt Product Data ~.~ - ~.~_~. ................ .... ¥-'~ ,~ . i.,L~_ .... ~ ] ~ ? ~~,,~:. · ........ ~~, ............. DIMENSIONAL DATA FOR CONTAINMENT FI~INGS (Inches) Containment. Size (in.) A B C D E F G HO~ W 3 4 6 8. 10 12 14 16 (mm) 6 7 14 - 7~ 8 14 6 8 9 16 11 11 13 ~ 20- 12 18 21~ 24 t5 2'1~ 26 24 '17 22~ 27 28 29 22~4 29 28 31 ~ (1) Length shown is for primary pipe size. 3 June 8, 2004 Environmental Management West Region RO. Box 5095 Room 3EO00 San Ramon, CA 94583-0995 877.823.9833 Phone 925.973.0584 925.867.0241 City of Bakersfield - CUPA Attn: Ralph E. Huey, Director Fire Department 1715 Chester Ave, Third Floor Bakersfield, CA 93301 RE: Certification of Financial Responsibility - Underground Storage Tanks Please find the enclosed copy of the annual State of California Water Resources Control Board's Certification of Financial Responsibility form to demonstrate financial responsibility for SBC/Pacific Bell and its affiliate's underground storage tanks. Also enclosed is a list, Exhibit A, of SBC/Pacific Bell sites that have underground storage tanks on the premises in your area of jurisdiction. I can be reached at (925) 823-6161 if you have questions regarding this correspondence. Andrew Taylor Senior Environmental Manager SBC Environmental Management Attachment: Certification of Financial Responsibility Exhibit "A" 2004 Financial Test of Self Insurance (Certificate of Insurance) EXHIBIT A 2004 UST FINANCIAL RESPONSIBILITY KERN COUNTY Agency · Location City Site Contact Bakersfield Fire Dept. 3221 So. "H" Street Bakersfield Linda Porter Bakersfield Fire Dept 1918 "M" Street Bakersfield Linda Port¥~'- Bakersfield Fire Dept 3501 Columbus Ave Bakersfield . Linda Porter Bakersfield 'Fire Dept 11609 Rosedale Hwy Bakersfield :Linda Porter Kern County Health Dept 925 .]efferson St Delano Linda Porter Kern County Health Dept 8313 ESegrueRoad Lamont Linda Porter Kern County Health Dept 1021 California St Oildale Linda Porter CERTIt~IC'ATE::OF I. NSu~N.CE~ v .Issue. Date: 06-09-2004 Certificate Number: 20208 INSURED: This is to certify that policies of insurance listed below have been issued to the named insured for the policy period indicated. Notwithstanding any requirement, term or condition of any contract or other SBC COMMUNICATIONS INC. document with respect to which this certificate may be issued or may pertain, the insurance afforded by PACIFIC BELL TELEPHONE COMPANY the policies described herein is subject to all the terms, exclusions, and conditions of such policies. 175 E. HOUSTON SAN ANTONIO, TX 78205 This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend, extend or alter the coverage afforded by the policies described below. i..:i E~E'(~-ivE:!: :::EXP'i~i~iO'N':'; LiMitS.OF'" .. i..iAB.iEiTY ..' :.. '" :': .., OTHER Gateway Rivers Insurance Co. 409-lUST001 12/31/2003 12/31t2004 PER OCCURRENCE $ 500,000 Environmental Impairment ANNUAL AGGREGATE $1,000,000 Liability for Underground and Above Ground Storage Tanks SEE A]-FACHMENT FOR CERTIFICATION LANGUAGE. :CANCELLATION : .:: .: :::: ...,..... ... ~..... ,. , ,.j..... ,,:. · : · Should any of the above described policies be cancelled before the expiration date thereo¢, the insurance company will endeavor to mail 30 days written notice to the certificate holder named below. Failure to mail such notice shall impose no obligation or liability of any kind upon the company, its agents or representatives, ~CERTIFICATE HOLDER.!;':;'.:' ':.;. PRODUCER CONTACT STATE OF CALIFORNIA American Risk Management, Requested By STATE WATER RESOURCES CONTROL BOARD P.O. Box 1530 ANDREW TAYLOR Burlington, VT 05402-1530 DIVISION OF CLEAN WATER PROGRAMS Requestor's Phone P.O. BOX 944212 925-823-6161 SAC RAM ENTO, CA 94244-2120 Issued By DJ ;AUTHORIZED'REPRESENTATIVE · : i. ' : For State Use Only State of California State Water Resources Control Board Division of Clean Water Programs P.O. Box 944212 ' Sacramento, CA 94244-2120 -- CERTIFICATION OF FINANCIA RESPONSIBILITY FOR UNDERGROUND STORAGE TANKS CONTAINING PETROLEUM ........... =A. 1 am required t6 demonstrate Financial Responsibility in the required amounts as specified in Se'etlon 2807, Chapter 18, Div. 2,, Title 23, CCR: [] 500,000 dollars per occurrence [] 1 million dollars annual aggregate or AND or [] 1 million dollars per occurrence [] 2 million dollars annual aggregate B. Pacific Bell Telephone Company hereby certifies that it is in compliance with the requirements or'Section 2807, (N .... frank Owner or Operator) Article 3, Chapter 18, Division 3, Title 23, California Code of'Regulations. The mechanisms used to demonstrate financial responsibility as required by Section 2807 are as follows: C. Mechanism Name and Address of Issuer Mechanism Coverage · Co.verage Corrective Third Party .TTpe Number' Amount Period Action Compensation Certificate of Gateway Rivers Insurance 409- $500,000 Per 12/31/2003- Yes Yes Insurance Company lUST001 Occurrence & 12/31/2004 76 St. ?aul St., Ste. 500 $1,000,000 Burlington, VT 05401-4477 Annual Aggregate Note: if you are using the State Fund as any part of your demonstration of financial responsibiliW, your execution and submission of this certification also certifies that you are in compliance with all conditions for participation in the Fund. D. Facillty Name Facility Addre~ Pacific Bell Telephone Company See Attachment Facility Name Facility Address Facility Name Facility Address Facility Name Facility Addr~s Facility Nan~ Facility Address Facility Name Facility Addrms Facility Hang FaciLity Address ~ Sig~ cr r O[~ ator Date Name and Title of Tank Owns' or Operator ~mit original to local'¥ST regulatt agency. Keep a copy at each UST facility. (Instructions on Reverse) Ubl-049 - 1/2 www.unidocs.org 01/29/02 40 CFR, 280.97 (b)[2) Certificate of Insurance Pacific Beil Internet, Svcs. Inc. Name: [name of each covered location]: See attached schedule Address:_ [address of each covered location] See attached schedule Policy Number: 409-lUST001 Endorsement (if applicable): Not Applicable Perio~ of. Coverage: 12/31/2003-12/31/2004 Name of Insurer: Gateway Rivers Insurance Company Address-of Insurer: 76 St. Paul Street, Suite 500, Burlington VT 05401-4477 Name of Insured: Per Certificate of Insurance Address of Insured: Per Certificate of Insurance Certification: 1. Gateway Rivers Insurance Co., the "Insurer", as identified above, hereby certifies that it has issued liability insurance covering the following underground storage tank(s): See Attached for "taking corrective action" and/or "compensating third parties for bodily injury and property damage caused by" either "sudden accidental releases" or "nonsudden accidental releases" or "accidental releases"; in accordance with and subject to the limits of liability, exclusions, conditions, and other terms of the policy; if coverage is different for different tanks or locations, indicate the type of Coverage applicable to each tank or location] arising from operating the underground storage tank(s) identified above. The limits of liability are $500,000 for "each Occurrence" and $1,000,000 "annual aggregate", limits of the insurer's liability; exclusive of legal defense costs, which are subject to a separate limit under the polic~y. This' coverage is provided under 409-1UST001. The effective date of said policy is 12/3 '1/2003- 1 ~./.~ 1, 2004. 2) The insurer further certifies the following with respect to the insurance described in Paragraph 1: a. Bankruptcy or insolvency of the insured shall not relieve the insurer of its obligations under the policy to which this certificate applies. b. The insurer is liable for the payment of amounts within any deductible applicable to the policy to the provider of corrective action or a damaged third-pat-fy, with a right of reimbursement by the insured for any such payment made by the insurer. This provision does not apply with respect to that amount of any deductible for which coverage is demonstrated under another mechanism or combination of mechanisms as specified in 40 CFR 280.95-280.102. c. Whenever requested by a Director of an implementing agency, the insurer agrees to furnish to the Director a signed duplicate original of the policy and ail endorsements. d. Cancellation or any other termination of the insurance by the insurer, except for non-payment of premium or misrepresentation by the insured, will be effective only upon written notice and only after the expiration of 60 days after a copy of such written notice is received by the insured. Cancellation for non-payment of premium or misrepresentation by the insured will be effective only upon written notice and only after expiration of a minimum of 10 days after a copy of such written notice is received by the insured. e. The insurance covers claims otherwise covered by the policy that are reported to the insurer within six months of the effective date of cancellation or non-renewal. Of the policy except where the new or renewed po[icy has the same retroactive date or a retroactive date earlier than that of the prior policy, and which arise out of'any covered occurrence that commenced after the policy retroactive date, if applicable, and prior to such policy renewal or termination datel Claims reported during such extended reporting period are subject to the terms, conditions, limits, including limits of liability, and exclusions of the policy. I hereby certify that the wording of this instrument is identical to the wording in 40 CFR 280.97(b)(2) and' that the insurer" is "licensed to transact the business of insurance," or "eligible to provide insurance as an excess or surplus lines insurer, in one or more states". Signature of authorized representative of Insurer: Type Name: Title, Authorized Representative of Insurer: Address of Representative: Paul W. Stephens Director & Executive Vice President Gateway Rivers Insurance Co. 175 E2 Houston, 7-P-60 San Antonio, Texas 78205 praxair Services, Inc. Technical' SolutiOns for the Industrial World, CERTIFICATION OF ELDsM TRACER TIGHT® TEST RESULTS Date: 05/03/04 Prepaired For: MJK Construction 7303 Sommerset Blvd Paramount, CA 90723 Job # 37344NC Site Info: SBC Bakersfield 3221 South H Street Bakersfield, CA Test Time Period 12 1 4~/2003 SYSTEM TRACER STATUS Diesel Tank A ~)~ ~% Diesel Vent Primary A ~.4 S ~ Diesel Product Primaq W ¢/~ ~_~' Diesel Return Primary W i¢'~ ~=~_~' Praxair Services Inc. certifies that the tank and product distribution lines listed in the above table have been tested by means of Enhanced Tracer Tight®. According to EPA standard test procedures for evaluating leak detection methods, the Enhanced Tracer Tight~ method is capable of detecting leaks of_>0.005gallons per hour with a Probability of Detection (PD) of 0.95 and Probability of false alarm of <0.05 Tester: -- Robert Caummisar Signature: ~ CA-Lic;# - 03-1665 .......... Date: 5-3-04 I declare under penalty of perjury that I am a licensed tank tester in the State of California and that the information contained in this report is true and correct to the best of my knowledge. The following criteria are used for the classification of leakage based on the presence or absence of tracer. PASS FAIL Criteria: Criteria: No Tracer Detected Tracer Detected July 22, 2004 Mr. James Stehr SBC Services, Inc. P.O. Box 5095 Room E3000S San Ramon, CA 94583-0995 FIRE CHIEF ADMINISTRATIVE SERVICES 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 852-2170 SUPPRESSION SERVICES 2101 "H" Street Bakersfield. CA 93301 VOICE (661) 326-3941 FAX 166]) 852-2170 PREVENTION SERVICES FIRE SAFETY SERVICES · ENVIRONMENTAL SEItVlCES 900 Truxtun Ave., Suite 210 Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 852-2171 FIRE INVESTIGATION 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 852-2172 TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399*4697 FAX (661) 399-5763 CLOSURE OF ONE UNDERGROUND HAZARDOUS SUBSTANCE STORAGE TANK(S) LOCATED AT SBC SA098, 3221 So. H Street in BAKERSFIELD, CA. PERMIT # BR-0320 Dear Mr. Stehr This is to inform you that this department has reviewed the results for the preliminary assessment associated with the closure of the tank located at the above stated address. Based upon laboratory data submitted, this office is satisfied with the assessment performed and requires no further action at this time. Accordingly, no unauthorized release reporting is necessary for this closure. If you have any questions regarding this matter, please contact me at (661) 326-3979. Sincerely, Howard H. Wines, III Hazardous Materials Specialist Registered Geologist No. 7239 Office of Environmental Services cc: J. Whiting, RWQCB 7303 Somerset Blvd. Paramount, CA 90723 (562) 663-1319 fax: (562) 663-1320 May 18, 2004 Agency: City of Bakersfield Fire Attn: Ralph E. Huey 1715 Chester Ave., Third Floor Bakersfield, CA 93301 Subject: UST MONITORING EQUIPMENT CERTIFICATE Enclosed please find the odginal copy of the UST Monitoring Equipment Certificates for the SBC facility located at BKFDCA14, 3221 South H Street, Bakersfield. The tanks/systems have been tested/calibrated in accordance with the manufacturer's instructions and meet the manufacturer's specification. A copy of the test results has been sent to the facility and will be available for review. Should you have any questions or need additional information, please call me at (562) 663-1319, or you may reach the SBC Environmental Manager, Andrew Taylor at (925) 823-8866. Madeliene Garcia SunWest E.C., Inc. ISBC-BKFDCA14 CA #: 193304 FACILITYADDREss:NAME:ii3221 SOUTH H ST. BAKERSFIELD I TELEPHONE 661-632-0653 MAKE AND MODEL OF MONITORING SYSTEM: IVEEDER ROOT TLS-350 [ S/N: A0874446605009 TANK 1 TANK 2 TANK 3 TANK CONTINUOUS MONITORING DEVICE CERTIFICATION CHECK LIST CONTACT PERSON: ANDY TAYLOR TEST DATE: [May 14, 2004 TYPE OF TANK: (DOUBLE OR SINGLE WALL) CONTENTS OF TANK: CAPACITY OF TANK: TYPE OF PRODUCT LINE: (GRAVITY, SUCTION, PRESSURE). TYPE OF PIPING (DOUBLE WALL OR SINGLE WALL) INDICATE THE SENSORS TESTED BY PLACING A YES, NO OR N/A IN CORRESPONDING BOX: TANK I/SENSOR TANK2/SENSOR TANK3/SENSOR TANK4/SENSOR SENSOR TYPE ANNULAR SPACE SENSOR: FILL SUMP SENSOR: PIPING SUMP OR PAN SENSOR: PIPING VAULT OR FIBER TRENCH SENSOR: DISPENSER CONTAINMENT SENSOR: TURBINE SUMP SENSOR: DOUBLE DIESEL 6000 SUCTION DOUBLE YES FLOAT YES FLOAT YES FLOAT N/A N/A N/A FOR PRESSURE TYPE SYSTEMS ONLY: DOES EMERGENCY SHUTOFF SWITCH WORK?: (REFUELING SITES ONLY) N/A I I DOES POSITIVE SHUT DOWN OCCUR IF MONITOR SYSTEM. IS TURN OFF?: N/A TANK 1 TANK 2 TANK3 TANK 4 IS ELECTRONIC IN~LINE LEAK DETECTOR PRESENT & TESTED?: IS MECHANICAL LINE LEAK DETECTOR PRESENT & TESTED?: DOES THE TURBINE SHUT-DOWN IF SYSTEM DETECTS A LEAK?: INDICATE THE FOLLOWING BY PLACING A YES, NO OR N/A IN APPLICABLE BOX: N/A N/A N/A IN TANK LEVEL GAUGING SYSTEM: TYPE OF IN-TANK LEAK DETECTION TEST PERFORMED BY MONITOR: DOES THE MONITORING SYSTEM HAVE AUDIBLE & VISUAL ALARMS? ELECTRONIC OVERFILL / MECHANICAL OVERFILL: IS THE MONITORING SYSTEM INSTALLED TO PREVENT UNAUTHORIZED TAMPERING? IS THE MONITORING DEVICES OPERABLE AS PER MANUFACTURE'S SPECIFICATIONS? YES CSLD YES YES YES YES ~GE TANK ~GE TANK CERTIFIED TESTERS ID #- SIGNATURE OF CERTIFIED TECHNICIAN: PRINTED NAME OF TECHNICIAN: ; ALMAZAN TESTING COMPANY: SUNWEST ENGINEERING GO. UNDERGROUNDST£ ABOVE GROUNDSTORAGE REPORT # 1040510-007 TELEPHONE: 562-663-1 ATTACH ALL CERTIFICATION DATA TO VERIFY THE INFORMATION ABOVE! SUNWEST ENGINEERING CONSTRUCTORS INC. LIC..~ 700190 CERTIFICATION OF COMPLIANCE TO MANUFACTURE'S SPECIFICATIONS FACILITY: SBC-BKFDCA14 REPORT NUMBER: 040510-007 LOCATION: 3221 SOUTH H ST. BAKERSFIELD CA 93304 This certifies that on May 14, 2004 an inspection and necessary service was performed on the VEEDER ROOT TLS-350 S/N A0874446605009 at the above location. The monitoring system, is in compliance with the manufacture's specifications and requirements. RUDY ALMAZ~N '- ' MONI RING SYSTEM CERTIFICATION , For Use By All Jurisdictions Within the State of California Authority Cite& Chapter 6 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name:SBC-BKFDCA 14 Site Address: 3221 SOUTH H ST. Facility Contact Person: ANDY TAYLOR Make/Model of Monitoring System: VEEDER ROOT TLS-350 B. Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment ins Tank ID: DIESEL FUEL ln-Tank Gauging Probe. Annular Space or Vault Sensor. Piping Sump / Trench Sensor(s). Fill Sump Sensor(s). Mechanical Line Leak Detector. Electronic Line Leak Detector. Model: 847390-108 Model: 794390-420 Model: 794380-208 Model: 794380-208 Model: Model: Tank Overfill / High-Level Sensor. Model: Other (specify equipment type and model in Section E on Page 2). Tank ID: [~ In-Tank Gauging Probe. ~ Annular Space or Vault Sensor. Model: Model: Piping Sump/Trench Sensor(s). Model: Fill Sump Sensor(s). M o d el: Mechanical Line Leak Detector. Model: Electronic Line Leak Detector. Model: Tank Overfill / High-Level Sensor. Model: Other (specify equipment type and model in Section E on Page 2). Dispenser ID: Dispenser Containment Sensor(s). Model: Shear Valve(s). Dispenser Containment Float(s) and Chain(s). DispenserlD: Dispenser Containment Sensor(s). Model: Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: Dispenser Containment Sensor(s). Model: Shear Valve(s). Dispenser Containment Float(s) and Chain(s). City: BAKERSFIELD Contact Phone No.: ( Date of Testing/Servicing: May 14, 2004 ~ected/serviced: Tank ID: Bldg. No.: Zip: 93304 800 ) 757-6575 In-Tank Gauging Probe. Model: Annular Space or Vault Sensor. Model: Piping Sump / Trench Sensor(s). Model: Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. M o de I: Electronic Line Leak Detector. M o de 1: Tank Overfill / High-Level Sensor. Model: Other (specify equipment type and model in Section E on Page 2). Tank ID: In-Tank Gauging Probe. Model: Annular Space or Vault Sensor. Model: Piping Sump / Trench Sensor(s). Model: Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. Model: Electronic Line Leak Detector. Model: Tank Overfill / High-Level Sensor. Model: Other (specify equipment type and model in Section E on Page 2). Dispenser ID: Dispenser Containment Sensor(s). Model: Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: Dispenser Containment Sensor(s). Model: Shear Valve(s). Dispenser Containment Float(s) and Chain(s). DispenserlD: Dispenser Containment Sensor(s). Model: Shear Valve(s). Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): I-~ System set-up report; [~ Alar/history repo_~ Technician Name (print): R._UDY ALMAZAN Signature: ,~~-----~'--'- -- Certification No.: 546025990 License No.: 703190 ,r Testing Company Name: SUNWEST ENGINEERING INC. Phone No.: ( 562 ) 663-1319 Page 1 of 3 03/01 Site Address: 3221 SOUTH H ST. Date of Testing/Servicing: May 14, 2004 D. Results of Testing/Servicing Software Version Installed: 324.01 Complete the following checklist: Yes ~ No* Is the audible alarm operational? Yes ~ No* Is the visual alarm operational? Yes [~ No* Were all sensors visually inspected, functionally tested, and confirmed operational? Yes U No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes U No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? [~ N/A Yes ~ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment [~ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) ~ Sump/Trench Sensors; ~ Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ~ Yes; [~ No. Yes [~ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no ~ N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? 90 % Yes* 1~ No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes* [~ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) [~ Product; [~ Water. If yes, describe causes in Section E, below. Yes [~ No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable Yes ~ No* Is all monitoring equipment operational per manufacturer's specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: Page 2 of 3 o3/m Monitoring System Certification Site Address:3221 SOUTH H ST. Date of Testing/Servicing: May 14, 2004 F. In-Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes ~ No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes Fl No* Were all tank gauging probes visually inspected for damage and residue buildup? Yes [~ No* Was accuracy of system product level readings tested? Yes ~ No* Was accuracy of system water level readings tested? Yes ~ No* Were all probes reinstalled properly? Yes [~ No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): ~ Check this box if LEDs are not installed. Complete the following checklist: q-Il Yes ~ No* For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? I-IlN/A (Check all that apply) Simulated leak rate: [~3g.p.h; I-[10.1g.p.h, ~0.2g.p.h. [~ Yes F1 No* Were all LLDs confirmed operational and accurate within regulatory requirements? Fl Yes Ill No* Was the testing apparatus properly calibrated? Fl Yes [~ No* For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Fl N/A ~-~ Yes I--~ No* For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? ~ N/A Fl Yes ~ No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or ~ N/A disconnected? ~ Yes ~ No* For electronic LLDs, does the turbine automatically shut off if any portion of thc monitoring system malfunctions ~ N/A or fails a test? Fl Yes I-II No* For electronic LLDs, have all accessible wiring connections been visually inspected? F'll N/A 1"3 Yes [~ No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: Page 3 of 3 o3/o~ Monitoring System Certification Site Address: 3221 S. "H" STREET UST Monitoring Plan GENERATOR ROOM /Monitol~ng System C<mtm~ Par~ CO BLDG. Date map was drawn: /_.~/ If you already have a diagram that shows all required information, you may include it, rather than this page, with your Monitoring System Certification. On your plan, show the general layout of the tanks and piping. Clearly identify locations of the following equipment, if installed: monitoring system control panel; sensor monitoring tank annular spaces, sumps, dispenser pans, spill containers, or other secondary containment areas; mechanical or electronic line leak detectors; and in-tank liquid level probes (if used for leak detection). In the space provided, note the date this plan was prepared. SBC Site Survey Exhibit "E" Environmental Management West Region SBC PST SITE SURVEY P.O. Box 5095 Room 3EOOO San Ramon, CA 94583 TANK MATERIAL SURVEY Site Location: SBC-BKFDCAI4 Address 3221 SOUTH H ST. County: KERN State: CA TANK SIZE 6000 Tank ID: 128o CLLC Code: SBC-BKFDCAI4 Site Contact ANDY TAYLOR Site Phone Number 661-632-0653 TYPE OF TANK UST[-"-X~ AST[~ [] 1. Single-wall [~ 2. Double-Wall (complete a separate survey for each separate tank) 3. Single wall in vault Compartments Tank(s) ONE TANK MATERIAL - PRIMARY TANK [] 1. Bare Steel ~ 2. Fiberglass/Plastic Manufacturer (if known): TANK MATERIAL - SECONDARY TANK ~ 1. Steel Clad w/FRP [~] 2. Fiberglass/Plastic MODERN WELDING CO. SPILL CONTAINMENT ~ 1. Spill Containment: Make, Model & Size [Photos Must Be Taken] PHIL-TITE Drain Valve Clean and in Good Operating Condition: OVERFILL PROTECTION EQUIPMENT 1. Electronic Remote Overfill Alarm (Audible & Visual) Functioning: Yes ~ No r'-[ Yes [] No r--] TANK MONITOR SYSTEM SURVEY (CONTINUED) Site Survey Exhibit "E" In Tank Gauge Type CAP Fuel-Level: 3645 MAG~-'~-'~-'~-'~-'~-'>~ CAP [~ MAG[~ Gallons Gallons $$.g8 Inches (mon) 55.50 Inches (stick) Water in. Tank: Yes Inches (mon) Inches (stick) No~-~ Yes ~-~ No~'~ Inches (mon) Inches (mon) CAP[~ MAG[~ Gallons Inches (mon) Inches (stick) Yes ~ Nor-] Inches (mon) Inches (stick) Inches (stick) Inches (stick) Water Present (In Sumps): Yes ~ Uo[--~ Where Present: Sump Pump. out: Waste Water Left on Site: Yes ~] Yes ~ Size of Drum(s) left, Gallons Pumped EMCC Contact Notified for Drum Removal: Name: Manway & Sump Conditions (include Penetrations, bolts, etc.) Site Photos Taken: Yes [~] No ~ Personnel Trained: Yes E~ NoE~ Date: May 14, 2004 Yes r-] No~"] Yes [-~ No[~ NoFq No[-~ Date: GOOD CONDITION, ALL BOOTHS IN PLACE Name: Date: Survey Performed By: Technician: RUDY ALMAZAN Tt Name) (Signature) TANK MONITOR SYSTEM SURVEY Manufacture: Model Number: ;T Site Survey VEEDER ROOT TLS-350 PLUS Status of Monitor System (Upon Arrival): Number of Tanks: ALL FUNCTION NORMAL, Sensors in Proper Position (Upon Arrival): Yes r~' N o ]-'"""""""'>~ Special Conditions (piping vault sensor, piping trench sensor, etc.) San Ramon EMCC Notified of Alarm: Modem Phone Number: Type of Modem Present: External Version Software TLS 350) Name: N/A Time: 661-832-8370 Internal 324.01 Tank Chart(s) Present Yes Manufacturers Tank Diameter (Chart) 95.75 Tank Diameter (Stick) 95.75 Total Tank Volume (Chart) Total Tank Volume (Monitor) 10152 10152 Exhibit "E" 2. Fill Tube Shutoff Valve (mechanical, make and model ff-) 3. Ball Float (Remove & Inspect if 1 & 2 above are not present) 1' Site Survey PIPING CONSTRUCTION SURVEY UNDERGROUND PIPING SYSTEM TYPE 1.Suction ~ 2. Pressure ~ LINE MATERIAL - PRIMARY LINE [~ 1. Bare Steel ~ 2. Flexible [~ 3. Copper ~ 4. Other: 3. Combination (suction/pressure) ~ 4. Gravity r-'l LINE MATERIAL -SECONDARY LINE [] 1. Fiberglass 2. Flexible 3. PVC - Plastic Compatible 4. Other: Manufacturer: WESTERN FIBERGLASS Exhibit "E" Present DISPENSER CONTAINMENT (FLEET SITES ONLY) 1. Dispenser Pan Mechanical Float In Good Working Condition: Yes [-~ No [] [~ 2. Electronic Dispenser Pan Sensor. Auto and Visual Alarm Auto Shutoff: Yes ~ No FILE THIS DOCUMENT IN THE HAZARDOUS MATERIALS PLAN, PROGRAMS, PERMITS, and PLANS BINDER SECTION 3 UST Monitoring and Respond Plan with Third Party Certification for the Monitoring Equipment 2004 SBC- BKFDCA14 - SA098 (Facility Name and ID) 3221 S. H STREET (Facility Address) BAKERSFIELD (Facility City) (Facility County) Maintain this UST Monitoring and Respond Plan with the Third Party Certifications until replaced, and/or updated with a new plan. THIS DOCUMENT IS REQUIRED TO BE POSTED ON SITE AND AVAILABLE FOR REVIEW BY GOVERNMENT AGENCY INSPECTORS, SITE ASSESSORS OR AUDITORS. THIS IS A CONDITION OF THE UST OPERATING PERMIT. Revised byAndrew Taylor 12/2/2003 I:\HAZMA'I~PACBELL\FORMS~SBC Monitor Plan Merge.doc Printed: March 16, 2004 page 1 ~,/~ EMCC: 2600 Camino Ramon, Room 3E000, San Ramon, CA 94583 ROUTINE MONITORING PROCEDURES Section 2632 (d)(1) Title 23 CCR, Chapter 16 UNDERGROUND FUEL STORAGE TANK Ao Bo Facility Name: SBC (BKFDCA14, SA098) Facility Address: 3221 S. H STREET, BAKERSFIELD Telephone: 661-398-4185 Tank Owner Name: SBC Tank Owner Address: 2600 Camino Ramon, room 3E000, San Ramon, CA 94583 Telephone: 800-757-6575 USTInstalled: 6,000-gallon double wall composite tank Containing Diesel' Fuel for the Emergency Generator. Piping Installed: Double Wall "Western Fiberglass" non-metallic flexible piping system for the product supply and return lines. The Frequency of Performing the Monitoring: Monitoring is performed continuously on the: · Double wall UST Interstitial space and its two sumps. · Monthly inspections of the TLS panel will be performed by SBC personnel to ensure proper operation. · Monthly inspections of the aboveground fuel piping will be performed by SBC personnel to ensure proper operation. · Enhanced Leak Detection (ELD) testing will be performed upon the initial tank installation and again within 6 months to ensure the system integrity. The methods and equipment used to perform continuous monitoring are: VEEDER ROOT Fuel Tank Monitoring System Model # TLS-350 Plus with CSLD Internal site-fax modem with printer 0.1 GPH magnetostrictive in-tank volumetric probe Model # 847390-107 Floating liquid sensors in the: 1. UST Interstitial space sensor Model # 794390-420 2. Piping sump sensor Model # 794380-208 3. Fill sump sensor Model # 794380-208 · Electronic Tank Overfill Alarm Model # 790091-001 I:~AZMAT~PACBELL~FORMS~SBC Monitor Plan Merge.doc Printed: March 16, 2004 page 2 Locations where monitoring is performed: (see the plot plan for physical location) Continuous monitoring and leak detection are performed: · In the interstitial space of the double wall UST · In the primary tank (by volumetric test) · In the piping sump · In the fill sump 1. The Site Manager, LINDA PORTER at 818-908-6044 is responsible for performing: · Operational monitoring On site record keeping, Note: Onsite records are maintained on a white board mounted in the facility. And label "Facility Information Center" and contains the UST Routine Monitoring & Response Plan, Hazardous Material Business Plan and other environmental records and permits. · The reporting of any discrepancies and alarms with the monitoring system, UST, piping, and associated hardware. 2. SBC - Environmental Management Control Center (EMCC) (California & Nevada region) at (800) 757- 6575 is responsible for all maintenance and repairs to the UST monitoring system, UST, piping, and all associated hardware. Reporting format: A site fax modem with auto-dial for up to 8 phone numbers is installed to fax all alarms and warnings 24 hours a day to SBC - Environmental Management Control Center (EMCC) (fax:925-867-0241) and to an alarm monitoring/maintenance company for alarms received by the TLS-350s. All on-site alarm are printed by the TLS-350 and maintained on site in the UST records box. SBC - Environmental Management Control Center uses computers with Internal Environmental Management software program for accessing/polling all facilities with Veeder Root TLS-350's three times a day, 7 days a week; for all: (1) inventory, (2) all alarms, (3) all warnings, (4) in tank leak detection, and (5) all sensors leak alarms, performing set up and programming changes, and system diagnostics with all data being stored in our database. I:~AZMAThUACBELLXFORMS\SBC Monitor Plan Merge.doc Printed: March 16, 2004 page 3 Preventative maintenance, calibration, certification to manufacturer's specification and repair for the UST monitoring system and associated hardware are performed on a minimum annually. SBC - Environmental Management Control Center directs, manages, and schedules all maintenance and repairs for the California and Nevada region's, UST's, piping, associated hardware, and UST monitoring systems preventative maintenance, calibration, certification and repairs. Currently SBC - Environmental Management Control Center (California & Nevada region) has an annual contract with Tait Environmental Systems, 701 North Parkcenter Drive, Santa Ana, CA 92705, Phone (714) 560-8222 or fax (714) 560- 8237 to perform Calibration and field services. Secondary Containment testing will be performed every 36 months. Training: SBC Hazardous Materials/Wastes Management Handbook, Section 20 Titled "Underground and Aboveground Storage Tanks" describes the methods and procedures company employees follow for underground and Aboveground storage tank and monitoring systems. UST and the Veeder Root TLS-350 monitoring system operating instructions are on- site. On-site training is performed on initial start-up of the UST monitoring system and refresher training is performed on an as needed basis. Training includes this Underground Storage Tank Monitoring Plan and the Operating manuals for electronic monitoring equipment. I:\HAZMAT~PACBELL~ORMS\SBC Monitor Plan Merge,doc Printed: March 16, 2004 page 4 UST RESPONSE PLAN (Section 2632(d)(2)Title 23 CCR, Chapter 16) UNDERGROUND FUEL STORAGE TANK Facility Name: SBC (BKFDCA14, SA098) Facility Addre. ss: 3221 S. H STREET, BAKERSFIELD Ae An unauthorized release of any hazardous substance (unleaded gasoline, diesel fuel) from the primary containment into the secondary containment (interstitial space, fill sump, piping sump, and piping vault) will be removed within 8 hours after the release has been detected, or contact our petroleum maintenance service contractor to remove the product from the secondary containment, and request additional time (as needed). Removal methods are by hand/electrical pump for small quantities and by vacuum truck for large quantities. Small quantities of any hazardous substance will be placed into steel drams. Large quantities will be placed into a vacuum truck tank. In the event of a release outside the secondary containment, the fire department will be contacted immediately calling 9-1-1. In the event of a non-emergency release the Bakersfield Fire Department will be notified at 661-326-3979. An SBC authorized vendor will perform removal and disposal of any hazardous substance. Spill Kits containing Absorbent pads are located on site in the BATTERY AREA for immediate Reponses to any release. Bo Name(s) and title(s) of the person(s) responsible for authorizing any work necessary under the response plan: Primary Contact: Title: Secondary Contact: Third Contact: Executive Contact: Title: Environmental Management Control Center Environmental Management Hotline OICC: Emergency Control Center 24 hours/day, 7 Days/Week Andy Taylor Environmental Manager Corporate Environmental Management Phone Number: 800-757-6575 (8am- 5pm) 866-1 WANT EM (8am- 5pm) Phone Number: 877-322-4722 Phone Number: 925-823-6161 I:~L~ZMAT~PACBELL~FORMS\SBC Monitor Plan Merge.doc Printed: March 16, 2004 page 5 I:\HAZMAT~PACBELLLFORMS\SBC Monitor Plan Merge.doc Printed: March 16, 2004 page 6 W~gTime:: Min~um:of:3h(Y~q~l~a~ttme ~ alk~ed :~etween:detiveri~: d~a:~=aeCt~on.: ~'database e~a[ualton :an~:blendlng :~lispe nse~i~ - E~iiuat~i: Mi~t': R:esea~h:!n~tut~:: I:~fA. ZMATLPACBELLLFORMSLSBC Monitor Plan Merge.doc Printed: March 16, 2004 page 7 :1277 I:\HAZMAT~PACBELL~FORMSXSBC Monitor Plan Merge,doc Printed: March 16, 2004 page 8 D~t~ctor: OUll~4!;:!¥pe;' qualitative unlb~a'ded aasbline diesel water 3;5t '3 40 3:03 0.011 0J)11 0:011 2.60 b:o,lO omo o.o'io <~ <1 <1 0.51 0."46 O48 0,011 GOO/ 0.007 < 1 <1 Comments: Senssrs are ,reuSable. 208 a~d:-209 sensors are also cempatible with 300 ser'~s I:\HAZMATWACBELLWORMS\SBC Monitor Plan Merge. doc Printed: March 16, 2004 page 9 BUSINESS NAME SBC MAP# 1 BKFDCA14 SA098 SITE MAP BUSINESS ADDRESS 3221 S. H STREET BAKERSFIELD DATE 3/16/2004 ZIP CODE 93304 RESIDENTIAL NORTH 4 COMMERCIAL AND RESIDENTIAL 6,000 GALLON UNDERGROUND DIESEL TANK AND PIPING 8 PI_ANZ ROAD 9 DRAWING SCALE NOT TO SCALE SYMBOl- LEGEND ELECTRICAL PANEL SHUT-OFF O NATURAL GAS SHUT-OFF (~ WATER SHUT-OFF Q EMERGENCY PUMP SHUT-OFF A TANK MONITORING fMA~ ALARM On TELEPHONE O Z~ FIRE EXTINGUISHER ,~k STORM DRAIN ~ SANITARY SEWER ~ STAGING AREA EVACUATION/ ~ HMMP, AND MSDS LOCATION ~-- FIRE HYDRANT x x FENCE (~ EMERGENCY RESPONSE EQUIPMENT/ABSORBENTS (--) ABOVEGROUND STORAGE TANK (~-~1 UNDERGROUND ~--~ STORAGE TANK <~ MOTOR OILS & LUBRICANTS (COMBUSTIBLE LIQUIDS) ,(~ BATTERY ELECTROLYTE (~ GASOLINE (FLAMMABLE DIESEL FUEL (COMBUSTIBLE LIQUIDS) NITROGEN (COMPRESSED GAS) Q ~ PROPANE (FLAMMABLE LIQUID) ACETYLENE (COMPRESSED GAS) ~ ANTIFREEZE/COOLANTS (~ WASTE OIL (FLAMMABLE LIQUID) ] FIRE PULL BOX A B C D E F G H I d K L M p1010288.jpg (1280x960x24b jpeg) p1010287.jpg (1280x960x24b jpeg) p1010268.jpg (1280x960x24b jpeg) p1010267.jpg (1280x960x24b jpeg) p1010266.jpg (1280x960x24b jpeg) p1010265.jpg (1280x960x24b jpeg) Che.~:er Ave.', 9akez~sfJ. e,Ld, CA 93301 326-3979 TANK ltENOVAL INSPECTI0N PLOT PLAN CONDITION OF TANKS k~.~ ~t0~ CONDITION OF. SOIL COMMENTS . ~,4~. OATE II~IIECTQIm NAME 8IQN~TU~ Bakersfield Fire Dept. Enironmental Services 1715 Chester Ave Bakersfield, CA 93301 Tel: (661)326-3979 ADDRESS ~ ' · ~ k · I II FACILI~CONTACT Business ID Numar 15-021 - t~.ii.:" ' '" ~"~ '~'' Section 1: BusineSs Plan and Inventory Program ........ [] Routine '~Combined [] Joint Agency [] Multi-Agency i'! Complaint ~ Re-inspection { C=Compliance '~ OPERATION COMMENTS % v=Violation BUSINESS PLAN CONTACT INFORMATION ACCURATE VISiBlE ADDRESS VERIFICATION OF INVENTORY MATERIALS VERIFICATION OF LOCATION PROPER SEGREGATION OF MATERIAL VERIFICATION OF MSDS AVAILABILIWE VERIFICATION OF HAT MAT TRAINING VERIFICATION OF ABATEMENT SUPPLIES AND PROCEDURES EMERGENCY PROCEDURES ADEQUATE CONTAINERS PROPERLY LABELED ~--~ I-R- ;~ 'P- ' ~;-~C~:~_~ ............. ~ __ ~- '~-.---' _-_~ ._~'--_~--~-- SITE DIAGRAM ADEQUATE & ON HANO ANY HAZARDOUS WASTE ON SITE?: [] YES /l~No EXPLAIN: QUESTIONS R~SPECTION? PLEASE CALL US AT (661) 326-3979 ~~ e~cto~-i~lea§e.13rint ) 0 ~~--~//f~~ ..... ~i-~ ~r e~-e-n~-0~-S t~l ~i~- o~ i~ ............... White - Environmental Services Yellow - S~ation Copy ~'~ ~-r~Y~(~ease Print) Pink - Business Copy FACILITY NAME CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CItECKLIST 1715 Chester Ave., 3r'~ Floor, Bakersfield, CA 93301 Section 2: Underground Storage Tanks Program [] Routine [~Combined [~ Joint Agency ~ Multi-Agency [~] Complaint ~ Re-inspection Type of Tank ,.~) [t_)?0_.,5 Number of Tanks Type of Monitoring O_,DW~ Type of Piping OPERATION C V COMMENTS Proper owner(operator data on file Permit fees current Certification of Financial Responsibility Monitoring record adequate and current Maintenance records adequate and current Failure to correct prior UST violations Has there been an unauthorized release? Yes No ...... Section 3: Aboveground Storage Tanks Program TANK SIZE(S). AGGREGATE CAPACITY · ·Type of Tank Number of Tanks OPERATION Y N COMMENTS sPcc available SPCC on file with OES Adsquate secondary protection Proper tank placarding/labeling Is tank used to dispense MVF? If yes, Does tank have overfill/overspill protection? C=Compliance V=Violation Y=Yes N=NO Office ofl~nv~onmental Service (~61) 32~-3979 ~ ~ While- Env. Svcs. Pink - Business Copy Business Site Responsible Party CITY OF BAKI~SFIELD OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (661) 326-3979 INSPECTION RECORD POST CARD Ar JOB SITE Facility Phone No. Owner~ ge. Pe=it# 6~- 03 q~ .So. ~'/4 ;~ q33o'~ INSTRUCTIONS: Please call i'br an inspector only when each group of inspections with the same number are ready. They will run in consecutive order beginning with number I. DO NOT cover work tbr any numbered group until all items in that group are signed offby the Permitting Authority. Following these instructions will ri:duce the number or' required inspection visits and therefore prevent assessment of additional fees. TANKS AND BACKFILL C~tho~c Pro,ect~on o~t~kCs) OW ~'_ S ' t/-( ?-~ cf '. ~ PIPING SYSTEM Piping&Raeewayw/CollectionSump QCtw'l/.:,4',...% ~,_~,,~,c..~ ~:~'~19 +l~O/O~ ~~ Co.sion Proration of Piping, Joinm Fill Pi~ El~tdeal I~lation of Piping From T~k(s) Cathodic Pmt~tion System-Piping SECONDARY CONTAINMENT, OVERFILL PROTECTION, LEAK DETECTION Liner Installation - Tank(s) Vault With Product Compatible Sealer Level Gauges or Sensors, Float Vent Valves Product Compatible Fill Box('es) Product Line Leak Detector(s) Leak Detector(s) for Annual Space-D.W. Tank(s) Monitoring Well(s)/Sump(s) - H20 Test Leak Detection Device(s) for Vadose/Groundwater Spill Prevention Boxes FINAL Monitoring Wells, Caps & Locks Fill Box Lock I Authorization fbr Fuel Drop __ CONTRACTOR LICENSE PERMIT APPLICATION TC~ONSTRUCT/MODIFY UNDERGROUND STORAGE'TANK TYPE OF APPLICATION (CHECK) CI NEW FACtLITY ~1 MODIFICATION OF FACILITY Fill Bakersfield Fire Dept. Environmental Service 1715 Chester Ave Bakersfield, CA 93301 Tel: (661)326-3979 ~.~_%NEW TANK INSTALLATION AT EXISTING FACILITY STARTI N~DAIE ~ [ , FACILITY M~ . TYPE OF 8~JSINESS / . ' [ - EXISTING FACILITY PERMIT NO. C TY , --. - ~ ZiP CODE APN # PHONE NO . -757 - (., 5 7.5- SPILL PREVENTION CONTROL AND CO~.UN,~ER MEASURES PLAN ON FILE ~ YES THIS SECTION IS FOR MOTOR FUEL TANK NO. VOLUME UNLEADED REGULAR .PREMIUM DIESEL AVIATION THIS SECTION IS FOR NON MOTOR FUEL STORAGE TANKS TANK NO. VOLUME CHEMICAL STORED (NO BRAND NAME) CAS NO (IF KNOWN) CHEMICAL PREVIOUSLY STORED FOR OFFICIAL USE ONLY The applicant has received, understands, and will comply with the attached conditions of the pe~it and any othe state, local and~ederal re~lations. This form has been completed under penal~ of ~perju~'~t°thjbest°~°wledge'ist~eandc°rrect'~~~~~ · ~~ ~~A ~ ~~_ ~ ~PROVED BY: ~PU~T ~E (PRI~) ~PLICANT SIGNA~RE THIS APPLICATION BECOMES A PERMIT WHEN APPROVED - PERMIT APPLICATION FO~EMOVAL OF AN UNDERGROUND STORAGE TANK Page 1 of 1 IPermitN° 6~-- 0 ~/0 { BAKnRS PlBLD Bakersfield Fire Dept. Environmental Se.vices 1715 Chester Ave Bakersfield, CA 93301 Tel: (661)326-3979 SITE INFORMATION ADDRESS ' FAC,L, NAME (5,kOq ) CR TREET CONT~CTOR INFORMATION PREL~INARYASSESSMENT INFORMATION I ~ANK CLEANIN6 INFOrmATION NUMBER N~E OF, ~NS~ TANK T~NSPORTER INFORMATION ?:,4 T~NKINFOR~ATioN CHEMICAL DA~S CHEMIC~ T~K No. AGE VOLUME STORED STORED PREVIOUSLY STORED s ! For ~icial Ua ~E APPUC~T HAS RECEIVED, UNDERST~DS; ~D ~ COMPLY ~ ~E A~ACHED COND/~ONS OF ~;S PERMIT AND ~Y O~ER STA~, LOC~ ~D FEDE~ REGU~TI~S. . TRUE AND C¢~C~ THIS APPLICATION WILL BECOME A PERMIT WHEN APPROVED "~NDERGROUND UST FACILITY Page I of I STORAG~ANKS BAKBRSPIBLD Bakersfield Fire Dept. Environmental Services 1715 Chester Ave Bakersfield, CA 93301 Tel: (661}326-3979 [~ 7. PERMANENTLY CLOSED SRE I. FACILITY/SITE INFORMATION NEAREST~ ~'¥2.SS STREE1=.~,~- J · 401 BUSINESS TYPE 1.GAS STATION 3. FARM ~5. COMMERCIAL 2.DISTRIBUTOR 4. PROCESSOR ~OTHER 403 TOTAL NUMBER OF TANKS.~ [is facility on indian Re~at[en or REMAINING AT SITE ~. ~41trustlands? ~l Yes ~No 405 FACILITY OWNER TYPE ~1. LOCAL AGENCY/DISTRICT* CORPORATION 04. O 2. INDMDUAL O 5.COUNTY AGENCY~ ~13.PARTNERSHIP [~ 6. STATE AGENCY* * If owner of UST a public agency: ~ 7.FEDERAL AGENCY* 402 Name of supervisor of division, section or office which operates the UST. (This is the contact person for the tank records.) 406 II. PROPERTY OWNER INFORMATION 4O9 PROPERTY OWNER TYPE {~ CORPORATION O 2. INDIVIDUAL ~13. PARTNERSHIP 410 ISTATE(~t~ 411 [ ZIP CODE O 4.LOCAL AGENCY/DISTRICT O 6.STATE AGENCY [~ 5. COUNTY AGENCY O 7.FEDERAL AGENCY 412 413 III. TANK OWNER INFORMATION ~TANK OWI~ER NAME _ t '1 [ ~ t f MAILING ~ STRE~A~DRE~__ ~ __~ ~ ~ ~ ~ . ~ ~D ~ ~D~bI ~ ~0~ TANK OWNER ~PE ~. ~R~ ~ 2. IND~DU~ ~3. P~ERSHIP O 4. LOCAL AGENCY/DISTRICT ~15. COUNTY AGENC~t' O 6, STATE AGENCY O 7, FEDERAL AGENCY 42O IV. BOARD OF EQUALIZATION UST STORAGE FEE V. PETROLEUM UST FINANCIAL RESPONSIBILITY iINDICATE METHOD(S) ~, SELF-INSURED 02, GUARANTEE I~ 3. INSURANCE O4. SURETY BOND D9. S'rATE FUND & CD 10. LOCAL GOV'T MECHANISM 99. OTHER: [~ 5. LE-I-I'ER OF CREDIT ~ 6. EXEMPTION [~ 7. STATE FUND [~ 8. STATE FUND & CFO LETr~R 422 VI. LEGAL NOTIFICATION AND MAILING ADDRESS 3heck one box to indicate which address should be used for legal notifications and mailing, %~ .egal notifications and maiiings will be sent to the tank owner unless box 1 or2ischeckad, O1. FACILII¥ [~2. PROPERTY OWNER ~(~. TANK OWNER 423 VII. APPLICANT SIGNATURE Certification: I certify that the information provided herein is true and accurate to the best of my knowladge. I 425 427 ISTATE UST FACILITY NUMBER (For local use only) 42811998 UPGRADE CERTIFICATE NUMBER '~or local use only) fd2069 UNIFIED PROGRAM CONSOLIDATED FORM TANKS UNDERGROUND STORAGE TANKS - TANK PAGE 2 VI. PIPING CONSTRUCTION (Check all that apply) Page -- of __ UNDERGROUND PIPING I ABOVEGROUND PIPING SYSTEM TYPE [] 1. PRESSURE 2- SUCTION [~ 3. GRAVITY 458 I [] 1. PRESSURE [] 2. SUCTION [] 3. GRAVITY 459 [-I 3. LINED TRENCH [] 99. OTHER 46o [] I. SINGLE WALL [] 95. UNKNOWN 462 [] 2. DOUBLE WALL [] 99. OTHER 461 MANUFACTURER 463 CONSTRUCTION [] 1. SINGLE WALL MANUFACTURER~2. DOUBLE WALL [] 95. ~OWN [] 1. BARE STEEL [] 6. FRP COMPATIBLE w/100°~¥~ M£THANOL [] 2. STAINLESS STEEL [] 7. GALVAN/ZED STEEL [] Unknown [] 3. PLASTIC COMPATIBLE W/CONTENTS [] 99. Other [] 4. FIBERGLASS ~8. FLEXIBLE (HDPE) [] 5. STEEL W/COATING [] 9. CATHODIC PROTECTION 464 [] 1. BARE STEEL [] 2. STAINLESS STEEL [] 3. PLASTIC COMPATIBLE W/CONTENTS [] 4. FIBERGLASS [] 5. STEEL W/COATING [] 6. FRP COMPATIBLE W/100% METHANOL [] 7. GALVANIZED STEEL [] 8. FLEXIBLE (HDPE) [] 99. OTHER [] 9. CATHODIC PROTECTION [] 95. UNKNOWN 465 VII. PIPING LEAK DETECTION (Check allthat apply) (A c UNDERGROUND PIPING SINGLE WALL PIPING 466 PRESSURIZED PIPING (Check all that apply): [] 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION + AUDIBLE AND VISUAL ALARMS. [] 2. MONTHLY 0.2 GPH TEST [] 3. ANNUAL INTEGRITY TEST (0.1GPH) CONVENTIONAL SUCTION SYSTEMS [] 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM + TRIENNIAL PIPING :s~ription of the monitoring pro,ram shall In sabmitted to the local a~ency.) ABOVEGROUND PIP/NG SINGLE WALL PIPING 467 PRESSURIZED PIPING (Cheek all that apply): [] 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK, SYSTEM FA/LURE, AND SYSTEM DISCONNECTION + AUDIBLE AND VISUAL ALARMS. [] 2. MONTHLY 0.2 GPH TEST [] 3. ANNUAL INTEGRITY TEST (0.1GPH) [] 4. DAILY VISUAL CHECK CONVENTIONAL SUCTION SYSTEMS (Check all that apply) [] 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM INTEGRITY TEST (0.1 GPH) SAFE SUCTION SYSTEMS (NO VALUES IN BELOW GROUNDPIPING): [] 7. SELF MONITORING GRAVITY FLOW [] 9. BIENNIAL INTEGRITY TEST (0.1 GPH) SECONDARILY CONTAINED PIPING PRESSURIZED PIPING (Check all that apply): 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND (Check one) [] a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS [] 6. TRIENNIAL INTEGRITY TEST (0.1 GPH) SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIPING): [] 7. SELF MONITORING GRAVITY FLOW (Check all that apply): [] 8. DAILY VISUAL MONITORING [] 9. BIENNIAL INTEGRITY TEST (0.1 GPH) SECONDARILY CONTAINED PIPING PRESSURIZED PIPING (Check all that apply): 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND (Check one) [] a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS [] b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM DISCONNECTION l-It. NO AUTO PUMP SHUT OFF [] 11. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITH FLOW SHUT OFF OR RESTRICTION [] 12. ANNUAL INTEGRITY TEST (0.1 GPH) SUCTION/GRAVITY SYSTEM [] 13. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS EMERGENCY GENERATORS ONLY (Check all that apply) 4. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF * AUDIBLE AND VISUAL ALARMS [] 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW SHUT OFF OR RESTRICTION [] 16. ANNUAL INTEGRITY TEST (0.1 GPH) [] 17. DAILY VISUAL CHECK [] b AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM DISCONNECTION []c NO AUTO PUMP SHUT OFF [] 11. AUTOMATIC LEAK DETECTOR [] 12. ANNUAL INTEGRITY TEST (0.1 GPH) SUCT/ON/GRAVITY SYSTEM [] 13. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS EMERGENCY GENERATORS ONLY (Check all that apply) [] 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF * AUDIBLE AND VISUAL ALARMS [] 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) [] 16. ANNUAL INTEGRITY TEST (0.1 GPH) [] 17. DAILY VISUAL CHECK VIII. DISPENSER CONTAINMENT DISPENSER CONTAINMENT DATE INSTALLED 468 [] 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE {~/2. CONTINUOUS DISPENSER PAN SENSOR + AUDIBLE AND VISUAL ALARMS [] 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER + AUDIBLE AND VISUAL ALARMS [] 4. DAILY VISUAL CHECK [] 5. TRENCH LINER / MONITORING [] 6. NONE 469 IX. OWNER/OPERATOR SIGNATURE 1 ce,ify that th~n~ormation provi~.l~ herein~true and .... te to the best of my knowledge. SIGNATURE o o'~9~o~O~TgL- . NAME OF ~ ~/OPRR'fO~R~rint ) 471 TITLE OF OWNER~OPER~kTOR ~ 474 ~]permit Expiration 9ate (For local use only) 47O 472 Permit Number (For local use only) UPCF (12/'99 revised) 473 Permit Approved (For local use only) 12 475 Formerly SWRCB Form B ~ w.IFIED PROGRAM CONSOLIDATED FOR_....~ TANKS UNDERGROUND STORAGE TANKS -TANK PAGE 1 (two pages per tank) Page __ of __ TYPE OF ACTION ~ NEW SITE PERMIT I'-] 4 AMENDED PERMIT [] 5 CHANGE OF INFORMATION [] 6 TEMPORARY SITE CLOSURE (Check one item only) [] 7 PERMANENTLY CLOSED ON SITE [] 3 RENEWAL PERMIT (Specify reason - for local use only) (Specify reason - for local use only) [] 8 TANK REMOVED 430 BUSINES SS~2~LNAME (Same~5~0qg las~FACILITY NAM~ or DBA - Doing Business As) 3 FACILITY ID: I ] I ] ] I 1 LOCATION WITHIN SITE (Optional) 431 I. TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the .local agency.) TANK[D# ~ 432 TANK MANUFACTURER ~ .~/~ ~_ ~ ~.~ , 433 COMPARTMENTALIZED TANK [-] Yes~ No 434 DATE IN~T?$[L_LED (YEARJ]VIO) 435 TANK C~d~pAC~Ty I~GALLONs ~ 436 NUMBER OF COMPARTMENTS 437 ADDITION/(L DESCRIPTION (For local use only) ~" ! 438 II, TANK CONTENTS TANK USE 439 PETROLEUM TYPE 440 I,~l. MOTOR VEHICLE FUEL [] la, REGULAR UNLEADED [] 2. LEADED [] 5, JETFUEL (If marked compile Petroleum Type) [] lb. PREMIUM UNLEADED ~. DIESEL [] 6. AVIATION FUEL [] 2. NON-FUEL PETROLEUM [] I c. M]DGRADE UNLEADED [] 4. GASOHOL [] 99. OTHER [] 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441 CAS# (from Hazardous Materials Inventory page ) 442 [] 4. HAZARDOUS WASTE (Includes Used Oil) [] 95. UNKNOWN IH. TANK CONSTRUCTION TYPE OF TANK [] 1. SINGLE WALL [] 3. SINGLE WALL WITH [] 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 (Check one item only) EXTERIOR MEMBRANE LINER [] 95. UNKNOWN ~ DOUBLE WALL [] 4. SIGNLE WALL IN VAULT [] 99. OTHER TANK MATERIAL - primary tank ~,~1. BARE STEEL [] 3. FIBERGLASS / PLASTIC [] 5. CONCRETE [] 95. UNKNOWN 444 (Check one item only) [] 2. STAINLESS STEEL [] 4. STEEL CLAD W/FIBERGLASS [] 8. FRP COMPTIBLE W/100% METHANOL [] 99. OTHER REINFORCED PLASTIC (FRP) TANK MATERIAL - secondary tank [] 1. BARE STEEL ~[-1.3. FIBERGLASS / PLASTIC [] 5. CONCRETE [] 95. UNKNOWN 445 (Check one item only) [] 2. STAINLESS STEEL~. STEEL CLAD W/FIBERGLASS [] 8. FPP COMPTIBLE W/100% METHANOL [] 99. OTHER REINFORCED PLASTIC (FRP) [] 10. COATED STEEL [] 5. CONCRETE TANK INTERIOR LINING [] 1. RUBBER LINED [] 3. EPOXY LINING [] 5. GLASS LINING [] 95. UNKNOWN 446 DATE INSTALLED ~7 OR COATING [] 2 ALKYD LINING [] 4 PHENOLIC LINING ~6 UNLINED [] 99 OTHER (Check one item only) (For local use only) OTHER CORROSION [] I MANUFACTURED CATHODIC ,~ FIBERGLASS REINFORCED PLASTIC [] 95 UNKNOWN 448 DATE INSTALLED 449 PROTECTION IF APPLICABLE PROTECTION [] 4 IMPRESSED C3JRRE2qT [] 99 OTHER (Check one item only) [] 2 SACRIFICIAL ANODE (For local use only) SPILL AND OVERFILL YEAR INSTALLED 450 TYPE (local use only) 451 OVERF1LL PROTECTION EQUIPMENT:YEAR INSTALLED 452 DROP TUBE BALL FLOAT [] 4 EXEMPT 1, ~.3 STRIKER PLATE IV. TANK LEAK DETECTION (^ description of thc monitoring program shall be submiited to the local ag~ocy.) IF SINGLE WALL TANK (Check all that apply) 453IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 (Check one item only) [] I VISUAL (EXPOSED PORTION ONLY) [] 5 MANUAL TANK GAUGING (MTG) [] I VISUAL (SINGLE WALL IN VAULT ONLY) [] 2 AUTOMATIC TANK GAUGING (ATG) [] 6 VADOSE ZONE [] 2 CONTINUOUS INTERSTITIAL MONITORING [] 3 CONTINUOUS ATG [] 7 GROUNDWATER [] 3 MANUAL MONITORING [] 4 STATISTICAL INVENTORY RECONCILIATION [] 8 TANK TESTING (SIR) BIENNIAL TANK TESTING [] 99 OTHER IV. TANK CLOSURE INFORMATION / PERMANENT CLOSURE IN PLACE ESTIMATED DATE LAST USED (YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 gallons [] Yes [] No UPCF (12/99 revised) 10 Formerly SWRCB Form B BAKERSFIELD FAX Transmittal COVER SHEET FIRE DEPARTMENT PREVENTION SERVICES 1715 Chester Avenue · Bakersfield, CA 93301 Business Phone (661) 326-3979 · FAX (661) 852-2172 TO: COMPANY: COMMENTS' Praxair Se ices, Inc. TeChniCal'~$ol~U~io~ ~ ~I~~rl~. ' ~'' UC¢SCO Date: 3/5/2004 Steve Underwood Bakersfield Fire Department Environmental Services 1715 Chester Ave. Bakersfield, CA 93301 661-326-3979 661-326-0576 Fax Re: Retest Report - SBC Site - 3221 S. H STREET BAKERSFIELD, CA The attached report is for the completed Enhanced Leak Detection testing performed for SBC Communications. No Tracer W was detected in the backfill on this site. No further action is required. If you have any questions regarding the testing or this report, please do not hesitate to call me. Sincerely, Andrew Koch III - Supervisor Office: 520-888-9400 Fax: 520-293-1306 INFORMATION CONTAINED WITHIN IS CONSIDERED CONFIDENTIAL, PROPRIETARY INFORMATION OF PRAX,41R SER I/ICES, INC. KemCoverLetter 105 FILE THIS DOCUMENT IN THE HAZARDOUS MATERIALS PLAN, PROGRAMS, PERMITS, and PLANS BINDER SECTION 3 UST Enhanced Leak Detection Test Report 2OO4 SBCIPacBell (SA098} BKFDCA14 (Facility Name and ID) 3221 S. H STREET (Facility Address) BAKERSFIELD (Facility City) KERN (Facility County) Maintain this UST Enhanced Leak Detection Test Report until replaced by a new test report. 'Testing Requirements:· Tri-annually on Standby Generator LIST's that are not secondary containment tested · When a new UST is installed THIS DOCUMENT IS REQUIRED TO BE POSTED ON SITE AND AVAILABLE FOR REVIEW BY GOVERNMENT AGENCY INSPECTORS, SITE ASSESSORS OR AUDITORS. THIS IS A CONDITION OF THE UST OPERATING PERMIT. Tracer Research C o r p o r a t i o n 3755 N. Business Center Drive Tucson, Arizona 85705 Toll Free (800) 989-9929 Tel: (520) 888-9400 Fax: (520) 293-1306 California Enhanced Tracer Tight® Leak Test February, 2004 Testing (1) Underground Storage Tank 3221 S. H STREET BAKERSFIELD, CA Tracer Job No. 30817U-0105RT Prepared for: SBC Services Andrew M. Taylor 2600 Camino Ramon, Room 3E000P San Ramon, CA 94583 Tel: (925) 823-8866 Fax: (925) 973-0584 Site Location: CLLC# BKFDCA 14 3221 S. H STREET BAKERSFIELD, CA Submitted by: Praxair Services, Inc. Andrew Koch IH - Supervisor E-Mail: Andy_Koch ~ Praxair.com Website: http://www. TracerResearch.com Inoculation By: Samples Collected By: Report Written By: Aric Giron - CA Tank Tester License # 03-1668 Andrew Koch- CA Tank Tester License # 01-1621 Andrew Koch- CA Tank Tester License # 01-1621 Site Location: 3221 S. H STREET Tracer Job No.: 30817U-0105RT Enhanced Leak Detection Testing Summary: Tank Piping Tracer System: Volume: Product: Type: Material: Material: Tracer: Detected: DW/Steel DW/Steel Tank 333 5,000 gal Diesel UST/Pipin~ Steel Clad Fiberglass W Pass Enhanced Leak Detection Testing Comments: Tank 333 - No Tracer W was detected in the backfill - No further action is required. General Comments: Site Location: 3221 S. H STREET Tracer Job No.: 30817U-0105RT Tank Piping Tracer S}/stem: Volume: Product: Type: Material: Material: Tracer: Detected: DW/Steel DW/Steel Tank 333 5,000 gal Diesel UST/Pipin~I Steel Clad Fiberglass W Pass Testin(~l Events: I System Survey Information: Installation: 03/27/2003 ' Pump System Style: Suction Inoculation: 02/02/2004 Inventory Monitoring Method: ATG Sampling: 02/19/2004 Tank Innerstitial Sensors ? Yes ' Analysis: 02/24/2004 Tank Sump Sensors ? Yes Dispenser Containment ? No I Installation Conditions: Dispenser Monitoring: i N/A Backfill: Pea Gravel Vapor Recovery Style: N/A Ground Cover: Concrete Soil Permeability: i >26.1 Darcys I Asphalt Water/Fueh Reading: Fill Riser I Spill Bucket Test: Groundwater: > 120" Test Duration: N/A TopofTank: 43" Start Level: i N/A Bottom of Tank: 134" End Level: N/A Product at Inoc: 78" Pass/Fail: i N/A , at Sampling: 76" Water was placed in the spill containment bucket for hvo hours - ~ Fail = loss of water, Pass = no loss. Loss of water indicates faully ! H20 at Inoc.: 0" drain valve or spill bucket/#$er connection. No inspection was at Sampling: 0" conducted to determine if loss impacted the backfill. Tank 333 - Data Analysis: Probe: W t../L) '1 0.000 2 0.000 3 0.000 ~ 4 0.000 5 0.000 ~ = o.ooo F1 0.000 TS1 0.000 Tank 333 - No Tracer W was detected in the backfill - No further action is required. Testin(~ Events: Installation: 03/27/2003 Inoculation: 02/02/2004 Sampling: 02/19/2004 Analysis: 02/24/2004 System Survey Information: Pump System Style: Suction Inventory Monitoring Method: ATG Tank Innerstitial Sensors ? Yes Tank Sump Sensors ? Yes Dispenser Containment ? No Dispenser Monitoring: N/A Vapor Recovery Style: N/A Soil Permeability: >26.1 Darcys Water/Fuel: Reading: Groundwater: > 120" Top of Tank: 43" Bottom of Tank: 134" Product at Inoc: 78" at Sampling: 76" H20 at Inoc.: 0" at Sampling: 0" Fill Riser I Spill Bucket Test: Test Duration: N/A Start Level: N/A End Level: N/A Pass/Fail: N/A Water was placed in the spill containment bucket for hvo hours - Fail = loss of water, Pass = no loss. Loss of water indicates faully drain valve or spill bucket/#$er connection. No inspection was conducted to determine if loss impacted the backfill. Tank 333 - Data Analysis: Probe: W (IJglL) 1 0.000 2 0.000 3 0.000 4 0.000 5 0.000 6 0.000 F1 0.000 TS1 0.000 Site Location: 3221 S. H STREET Tracer Job No.: 30817U-0105RT 18-5' P1 T1 A,B,R,W TVHC mg/L ATG1 F1 FVRS1 PI1 TI1 TS1 VRI EXPLANATION OF ABBREVIATIONS Probe-Depth'. The number before the hyphen gives the location number of the probe from which the sample was collected. The location of the given probe is given on the accompanying map, usually Figure 1. 'The number after the hyphen gives the depth, usually in feet, at which the sample was collected. The apostrophe indicates that the depth is in units of feet. Piping Trench 1. Indicates the beginning of a section in which the listed results that follow are associated with the piping at the facility. Tank 1. Indicates the beginning of a section in which the listed results that follow are associated with tank number one. Tracer. Each tracer chemical used during the test is identified with a letter designator. Micrograms per Liter. Tracer concentrations are listed in units of micrograms per liter. Total Volatile HydroCarbons. The concentration ofhydrocarb0n vapors is determined for each sample. Milligrams per Liter. The concentration of hydrocarbon vapors present in each sample is listed in units of milligrams per liter. Automatic Tank Gauge, Tank 1. A sample with this designator was collected below the manhole cover and outside the access riser for the automatic tank gauge. Fill, Tank 1. A sample with this designator was collected inside the sPill bucket at the fill riser. Fill-Vapor-Recovery-Riser Sump, Tank 1. A sample with this designator was collected from the sump containing the fill riser and the vapor recovery riser. The sample was collected below the spill buckets. Pipe Interstice, Tank 1. A sample with this designator was collected between the primary and secondary containment walls of the double walled piping. The piping interstice is accessed inside the turbine sump. Tank Interstice, Tank 1. A sample with this designator was collected inside of and at the bottom of the access riser for the space between the primary and secondary containment walls of the tank. Turbine Sump, Tank 1. A sample with this designator was collected from inside the turbine sump. Vapor Recovery, Tank 1. A sample with this designator was collected inside the spill bucket at the Stage I vapor recovery riser. Site Location: 322'1 S. H STREET Tracer Job No.: 30817U-0105RT SITE MAPS Sampling Location Figure 1 ~oration Tank Fill 5,000 9al Diesel Tracer '5 .~i~ a r k i n g Lot Driveway E X P L A N A T I O N · 1 S~npling Probe Location ...... Approximate Pipeline Location 0 f e e S BC 2O B u i 1 d i n 9 SITE# 105 GEO PAR# SA098 TRC JOB# 30817U-105~ S B C S E R V I C E S C L L C # B K F D C A 1 4 BAKERSFIELD, C A L I F 0 R N I A SAMPLING LOCATIONS Figure 1 Site Location: 3221 S. H STREET Tracer Job No.: 30817U-0105RT FIELD DOCUMENTATION Inoculation Form Sampling Chain Of Custody Forms Tracer Researc.h Corporation Job No. 30817U-0105RT Period: 01-30-2003 SBC-3221 S. H STREET, BAKERSFIELD, Inoculation Lnformation: I In°culat°r:~~tC' ~V'ot'X I Date: Og./oZ/c~ CA Tank Tester Licenseg: I SBC-BKFDCA14 - Inoculation Form Address~ .... USA City: BAKiERSFIELD State: CA Zip: Source: DataTrace 2.0 System Number ~Name: Volume: Product: Type: Dia: Len: Hgt: BTDp PRLv TWLv GWDp Furl ~g,,.o,,~ ~i,, /eetj ~i, i,,¢he,~j ltcvd TPF TRC Lbs. TRC Cans Ingress: Probe List: Fac: El05 Facility El05 Address: BKFDCAI4 lnoc. Date: / / Comments: (Probe Replacements Needed ?, Dig Permits Requested Inoculation Form: SBC-3221 S. H STREET (30817U-OI05RT) Ihtoculation Cottfirmed By: Page I of I Pr~ AKoch ~ Facility: System: Collector: ot~: p r o b e (s): Depth: Cover: Vacuum: PRLv rrgLv Date/Time: Comments: Compound: /lnDate: ~ i (in inches} EI05 333 Air Blank I AIR001 i Air ~l~//Az/ ~' tvhc t EI05 AIR001 k Tightness Test Tank 333 2 El05 353 Individual I I ?1 \ / ~., tvhc I El05__! A: Tightness Test Tank 333 El05 333 Individual 1 2 ~ tvhc I E105._2 A: Tightness Test Tank 333 E]05 333 individual 1 3 ? , tvhc I £105__3 A: Tightr~ess Test Tank 333 E105 333 Individual 1 4 ~ ~, tvhc 1 E105_4 5 A: Tightness Test Tank 333 El05 333 Individual I 5 ~ tvhc 1 I E105_$ 6 A: 13ghtness Test Tank 333 El05 333 Individual I 6 ~ ,, tvhc I E105_6 ^: Tightness Test Tank 333 El05 333 Individual I Fl ? L tvhc I EI05_FI A: Tig[~tness Test Tank 333 EI05 333 Individual I TII ? , tvhc I EI05_TII A: Tightness Test Tank 333 lo El05 333 Individual I TSI ~ \ ., tvhc I EI05._TSI A: Tightness Test Tank 333 I, Chain of Custody Form: SBC-3221 S. H STREET (30817U-0105RT) L...----] rum~ MAR-05-2004 10:18 I RONMENTAL MGMT Praxair Services, Inc. T~cl~ical 8olmtiorm tm' I~ Indusl~at We~. Date: 31512004 925 867 0241 P. 82 Steve Underwood Bakersfield Fire Department Environmental Services 171S Chester Ave. Bakersfield, CA 93301 661-326-3979 661-326-0576 Fax ' Re: Retest Report - SBC Site - 3221 S, H STREET BAKERSFIELD, CA Thc attached report is for thc completed Enhanced Leak Detection testix~8 per. formed SBC Communicat/ons. No Tracer W was detected in the backfill on this site. No further action is required. If you have any questions regarding the t~sting or this rcport, please do not hesitate to call Sincerely, Andrew Koch III. Supervisor Office: 520-888-9400 Fax: 520-293-1306 IffFOI~4TION CONTAINF_~D WITHIN IR CONSIDERED CONPID~VTIAI~ PROPRIETARY INFOR&L4TION OF PJbtXAIR ~,ZI'IC~ INC. KemCoverLetter105 MAR-05-2004 10:18 ~RONMENTAL MGMT FILE THIS DOCUMENT IN 1'HE HAZARDOUS MATERIAL,8 PLAN, PROGRAMS, PERMITS, and PLANS BINDER 925 86'7 0241 P. 03 SECTION 3 UST Enhanced Leak Detection Test, ,Report 2004 SBClPacBell (SA098} BKFD,,CA14 IIII II / . -- ' - 1Facility Name and ID) 3221 S. H STREET I I I I (Facility AddresS).- BAKERSFIELD " (FaCilitY'City) ' "" KERN (FaGility r,.;ounfiJ) ~. '" _ ~ II II Maintain this UST Enhanced Leak Detection Test Report until replaced by a new test report. Testing Requirements: · Tri-annually on Standby Generator UST's that are not secondary containment tested · When a new UST is Installed TI-ES DOCUMENT IS REQUIRED TO BE POSTED ON STT'E AND AVAILABLE FOR REWEW BY GOVERNMENT AGENCY INSPECTORS, SI-I'E ASSESSORS OR AUDI'rOR5. THIS IS A CONDI-I-iON OF THE UST OPERA-I-[NG PERYlI'i'. ~flR-1~-2004 10:~8 ~ RONMENTAL MGM[ ?racer Research · C · r p o r a t i o n 867 0241 P.04 3?55 N. Bpsiness Center Drive, Tu~on, Arizona 85705 Toll Free (800) 989-9929 Tel: (520) 888-9400 Fax' (520) 293.1306 Preuar_e~ for: SBC Services Androw M, Taylor 2600 Camino Ramon, Room 3E000P StaXR~ao~ CA 94553 Tel:' (925) 823-8866 Fa~: (925) 973.0584 Submitted by; Prax~ir SeFviees, inc. Andrew Koch 111 - Supervisor ~-MnlI: Andy~Koeb ~ Prualr.com Web~lte: btm ://www. TruccrR~ca~,h...,cg,.m, California Enhanced Trncer Tight. Leak Test February, 2004 Tegong (1) Underground Storage 3221 S. H STI~F.T BAKERSFIELD, CA Tracer Job No. 3081'/U-0105RT CLLC# BKFDCA14 3221 S. H STR]SWI' BAKERSFIF..LD, CA lnoq~lntion By: Samples Collected By: Rel~rt W~itten By: Aric Giron - CA. Tank Tester 12cease # 03-1668 Andrew Koch- CA Tank Tester License # 01-1621 Andrew Koch- CA Tank Tester Ucense # 01-16.7,1 MA~-05-200~ 10: l~ ~ RONMENTAL M~' Site LocaUon; 3221 S. H STREET Enhanced Leek Detection Testing Summary: 925 867 0241 P.05 Tracer Jeb No.: 30817U-0105RT .... Tank Piping Tr~" ~II}.~..t. em: Volume: Product; Type: Material: Maim'Iai: Ti'acer: Detected: DW/Ste~I" DW/S~el Tank 3~ 5,000 gel Diesel USTIPiplng.. ~1 Clad ~iberglass _. ~, P~s Enhanced Leak Detection Testing Comments: Ta~k $3~ - No Tracer W wat detected in th~ backtUl - No fuffller action is required, Comments: MAR-05-2004 10:18 I RONMENTAL MGMT 925 86? 0241 P.OG Site Location: 3221 S. H STREET Tracer J,ob No.~ 30817U-O105RT '1 Tank Piping Tracer , ,~tem: Volume:. Product: Type: M, ,atarial: Mat,e, rlal: ?mlc4ar: Detected: DWlSteel DW/Steel ?ank 333 5r000..~al I~esel .. UST/PJping ,Steel C~ad Fiberglass W, ..... Pass 'Te~! _n(Events, i .... System 8,urv.~ ihrOrma, o'~, ...... i' 'i~stallation: 03127/2008 Pump System Style: ! _$..u~on Inoculation: 02/02/~004 Inventory Monito~ng MethOd~~ AT,G SamEing: 02/19/200~ Tank 10nerstiflal Sensom ? Yes ___ I Analysis: 0;~/24/200:~ - ", , Tank~ $__ump ~8ensom ? i Yes ' ' DJ.spenser Containme,nt ?' No Installation,Conditions: i , Dispenser Monitoring.:, N/A I Backfill: Poe Grovel i Vapor RecOvery Style:, NIA GmundCo~ec. Concrete -~ Permeability:.,, >26.1 0arC~S , Asphalt ......... Water/~uel.'- ' Reading: , , "~:111 Riser I Spill Bucket TeSt: Gm~n~aten >120", .... ' Test Duration; -NIA Top of Tank:- 43' Start Level:' N/A B'~I of Tallk: 1,~4" , " F:r~ Level: -~'a!,lnoc: "78"-' ' Pass/Fall'i' N~' ' F~=/a~s afw~ler, PaSs= no/o~. .. H20 at Inoo,: O" ~ va~e or.~ bu~eWs~onnecaze. I~ I~S~.lion __ atSaml~ing:' ,,,,0" ___ ,Tank 333 - Data Anal),s?: P _robe.'" ' W ma~LL_.._ ] 0.000 ~ ,.,I 3 0,000 , 4 I - o.ooo ....... --- i 6 ~ - 0.000 ' ' ....... I . ' o.ooo i .... I,i --- o.6oo ..... i .... I .... I i ' .... I ........ I Teak 3:~3: ~To Trac~-W was detected tn the '~["~'kfill - No ftather a~dan is feqt~ited. -- TeStln~ Events, i' '~stallation: 03127/2008 Inoculation; 02/02~004 Same[ing: 02/19/200~ Analysis: 02/24/200~ - ' System Survey Informatlo'n, i,' '" Pump system Style: 8...uolJon InventOry Monito~ng Method; AT,G Tank 10nerstiflal Sensom ? Yes " , , Tank Sump :~ensor~ ? Yes ~ Di.spense~-C0ntainme,nt ?' No , Dispenser Monitoring.:, N/A .....Vapor Recovery S,tyle: NIA Soll Permeability:, >26d Oarc~s Water/~uel: Reading: , em~n~aten >120",. Top of Tank: 43" H20 at In~,; O" "~111 Riser I Spill Bu;ket TeSt: Test Duration: NIA Start Level:' N/A End Level: ' Pass/Faih N/A F~/a~s afw~ler, Pil~= no/o~. ,Tank 333 - Data Ana~s!,s: , ,, Probe." W (~,L~ .... ] 0.000 , .,I 2 0.000 3 0.000 4 0.000 5 0.000 6 0.000 FI o.000 0.600 MAR-~5-20~4 10:19 RONMENT~ MGMT Site ,Location: P1 T1 A,B,R. W TVI-IC ATO1 Fl FVRS ! TII TS1 VR1 925 8/57 0241 P.07 3221 S. H STREET Tracer Job No.: 308't?U-0105RT EXPLANATION OF ABBREVIATIONS Probe-Dopth'. The numb0r b0fore the hyphen gives lira location number of the.probe from which the sample was collecl~. The location of file given probe is given on the accomptmyin8 map, u,sually Fisure 1. The number after the hyphen gives the depth, usually in foot. at which ~he sample was collected. The apostrophe indicates that the depth is in units of feet. Pipivll Teanch 1. lndicstes the betinnir~ ora sec~on in which the listed results ~at follow are associated with tim pipinl~ at thc facility. Tank 1. Indicates the beginnin$ of a section in which ~he listed results that follow are associal~d with tank Tracer. Each tracer chemical ~ed during the teat is identified with a letter designator, Micrograms per I. itel'. Tracer cor~cenlrations are listed i~ mits ofmiero/rarr~per liter. Total Volatile HydroCarboDs, The c~mcentrati/m of hydrocarbon vapors is determined for each sample, MlllilFsms per Liter. The concentration of hydrocarbon vapors present in eac.h sample is listed in units of milligrams per liter. Automatic Tank Gauge, Tank I. A sample with this designator wa~ collected below the manhole cover and oumide the access tis= for the automatic tank gau~e. Fill, Tank 1. 'A sample with this desalinator was collected inside the spill bucke~ at the fill riser. Fill-Vapor-Recovery-Riser Surely, Tank I. A sample with this designator was collected from the sump containing the fill riser and the vapor recovery riser. TI~ sample was collected below ~hc spill buckets. Plpc Inters0ce, TaDk 1. A sample with fl~is designator was collected between O~c primary and secondary con~inment walls of thc double wailed pipinE, The pipin~ interstice is accessed inside the turbine surrq~. 'l'ank Interstice, Tank 1. A sample wi~h Ibis designator was collected inside of and at the bottom of'thc access riser for the space bezweeo the prb~ary and secondary con~nme~t walls of the ~ Turbine Sump, Tank 1. A san~le with this designator was collected from inside thc turbine sump. Vapor Recovery, Tank 1. A sample with this dasi~awr was collected inside rite spill bllcket at the Slate I vapor recovery riser. MAR-05-2004 10:19 Site Location: 3221 $, H STREET 925 86? 0241 P.08 Tracer Job No.: 30517U-0'IOSRT SITE MAPS Sampling Location yb"&,'r OX':T. la'I'g'G Ia.]'Z:~E]'TUG l'nOCgl~::[olr L ~',n,'s T.G MAR-05-2004 10: l~ ~RONMENTAL MGMT Site Location: 3221 S. H STREET 925 86? 0241 P. 10 FIELD DOCUMENTATION Inoculation Form Sampling Chain Of Custody Forms z .Lt,gc~ b'e8~l. L,r.p C01,bo_LsI:IOU , t I.UOCfli~.. OU,lUtOuuuf~u: I 'SBC',BKI::DC~.I4 - lUOCfllg!tou I:OUU ~ Z m Z *~,~ Tait Environmental Systems UST Construction · Design · Maintenance · Compliance October 27, 2003 Certified Mail- Return Receipt Requested Mr. 'Steve Underwood Fire Bakersfield City Dept 1715.Chester Ave., 3r? Floor Bakersfieid,:CA 93301 -~ 'Re: pacific Bell Site & CLLC Code: 3221 S: "H" Street~ Bakersfield Geo Par: SA-098 Dear Mfi Undb~o-od.~- iEnclOSed is the following form for the above-referenced facility: Spill/Overfill Containment Box Form- Feel-free to Call if you have any questions. Very TrulY Yours, TAIT ENVIRONMENTAL SYSTEMS . ALAN IHROCKMO._RTON compliance Manager .. AT:CB Enclosure :\tes\pb2003\letters\kem\u nderwood.st4 CC: Andy Taylor Ham/Dyck (Post At Site) CLLC: BKFDCA14 CA Lic #588098 · AZ Lic #095984 ° NV Lic #0049666 · ' *1863~N'orth 'NeVille Street · Orange, California 92865 · 714.560.8222 · 714.685.0006 Fax 3283 Luyung Drive · Rancho Cordova, California 95742 · 916.858.1090 · 916.858.1011 Fax www. SB989.com ~~---~~it Environmental Systems UST Construction · Design · Maintenance · Compliance SPILL/OVERFILL CONTAINMENT BOXES TEST DATE: 10/22/03 GEO PAR: SA-098 CLLC: BKFDCA14 Test Method Developed By: [] Spill Bucket Manufacturer [] Industry Standard [] Professional Engineer [] Other (Specify) Test Method Uses: [] Pressure [] Vacuum [] Hydrostatic [] Other (Specify) Measuring Equipment Used for Testing: MARKER/VISUAL Bucket Diameter: 11.5" Bucket Depth: 10.5" Wait time between applying pressure/vacuum/water and '15 MINUTES starting test: Test Start Time: 1:20 P.M. Initial Reading (Ri): 4.5" Test End Time: 1:50 P.M. Final Reading (RF): 4.5" Test Duration: 30 MINUTES Change in Reading (RF-RD: . 0 Pass/Fail Threshold: 0 Comments - (include information on repairs made to facilitate a passing test and indicate whether a permit was obtained for the repairs) CA Lic #588098 · AZ Lic #095984 · NV Lic #0049666 1863 North Neville Street · Orange, California 92865 · 714.560.8222 · 714.685.0006 Fax 3283 Luyung Drive · Rancho Cordova, California 95742 · 916.858.1090 · 916.858.1011 Fax www.tait.com oServices, Inc. · Box 5095 m SE000 San Ramon, California 94585 Phone 925-825-9855 Fax 925-975-0584 Fax 925-867-0241 May 1,2003 City of Bakersfield Certified Unified Program Agency (CUPA) Ralph E. Huey - Director of the Office of Environmental Services Fire Department 1715 Chester Avenue, Third Floor Bakersfield, CA 93301 RE: Certification of Financial Responsibility - Underground Storage Tanks Please find the enclosed copy of the annual State of California Water Resources Control Board's Certification of Financial Responsibility form to demonstrate financial responsibility for SBC/Pacific Bell and its affiliate's underground storage tanks. Also enclosed is a list, Exhibit A, of SBC/Pacific Bell sites that have underground storage tanks on the premises in your area of jurisdiction. I can be reached at (925) 823-6161 if you have questions regarding this correspondence. Stan Brodecki Senior Environmental Manager SBC Environmental Management Attachment: Certification of Financial Responsibility Exhibit "A" 2003 Financial Test of Self Insurance (CFO Letter) EXHIBIT A 2003 UST FINANCIAL RESPONSIBILITY KERN COUNTY Agency ! Location City ~ Site Contact Bakersfield Fire Dept 3221 So. "H" Street Bakersfield Harry Dyck Bakersfield Fire Dept 1918 "M" Street Bakersfield Harry Dyck Bakersfield Fire Dept 3501 Columbus Ave Bakersfield Harry Dyck Kern County Health Dept 925 Jefferson St Delano Harry Dyck Kern County Health Dept 8313 E Segrue Road Lamont Harry Dyck Kern County Health Dept 1021 California St Oildale Harry Dyck Bakersfield Fire Dept 11609 Rosedale Hwy Rosedale Harry Dyck For State: Use Only . .' .: State of California ;.:~ '? ":::': D visionofaean WaterProvams :. i.:'';I i"::' :! !i.: i:i.' .P.O. Box 944212 ;~:.:::'.:'.':' :. ::..:..::./~:.-' ·: ...... ,. . .: .:'.. i '.~?:!. Sacramento, CA 942¢¢-2120 CERTIFICATION. OF FINANCIAL RESPONSIBILITY FOR UNDERGROUND STORAGE TANKS CONTAINING PETROLEUM 2.~. [ am req~ired t~ dem~ustrate Financia~ Resp~n~ibi~iry in the requ[red am~un~ as $p¢¢i~e~. in S¢cti~n 28~?~ Chapter t8~ Di¥. ~ Tit[e ~]~ CCR: '1-] 500,000 dollars per occ~ence '~ I ~llion dollars a~ual aggregate or A~ or ' ~ 1 ~Hion dollars per occu~ence ~ 2 ~llion dollars a~ual aggregate B. SBC/Pacific Be[I hereby certifies that it is in compliance with the requirement~ o$Secti~n 2807, (Na~ o~'~a~ 0,~ or ~v~) ~ticle 3' Chapter 18, Division 3, Title 23, Cali[amia Code of Regulations.' ~e mechanis~ used to demons~'ate ~manciaI responsib/liW as requked by Section 2807 are as ffoltows: C; Mechanism ' Name and Address.of~ssuer Mechani~ · Coverage .. Coverage Co~ective Third party T~e · Number ' ,~ount Pe~od. Action Compensation FinanciaITes~oF Pacific Bell Not ~1,000,000 Pc? Annual May l, Yes Yes Self Insurance Finance Applicable Occu~ence & 2003 - April 2600 Camino Ramon for State $2,000,000 36, 2004 ~a 4CN I00 Alternative Annual San Ramon, CA 9~583 Mechanism Ag~egate Note: if you are using the State Fund asany part off your demons~ation off financial responsibiliW, your execution and submission of this certification also certifies that you are in compliance ~th al[conditions for participation in the Fund. D. Facili~ Na~ Faeili~ SBC/Pacific Bell See Exhibit "A" ~aciii~ Na~ F acili~ F acili~ Na~ Facili~ Facili~ Na~ , F ~cili~ Subn~it original to local UST regulatory agency. Keep a copy at each UST facility. (Instructions on Reverse) UN-049 - 1/2 www.u nidocs.or,,~ 01/29/02 LETTER FROM CHIEF FINANCIAL OFFICER I am the chief financial officer of Pacific Bell, 2600 Camino Road, Foom 4CN100, San Ramon,. California. This letter is in support of the use of"the financial test of self-insurance,'~ to demonstrate financial responsibility for taking corrective action and/or compensating third parties for bodily injury and property damage caused by sudden accidental releases and/or nonsudden accidental releases tn the amount of at least One Million Dollars ($1,000,000) per occurrence and Two Million Dollars ($2,000,000) annual ag~egate ar/sing from operating certain undergound storage tank(s). Undergound storage tanks at the following facilities are assured by this financial test or a financial test under an authorized State progam by this "owner or operator": Exhibit A contains the name and .addresses of each such facili'ties. Ail Underground Storage Tanks are assured by this financial test and a financial test under a State progam approved under 40 CFR Part 281. g~ "financial test," is also used by this "owner or operator," to demonstrate evidence of financial responsibility in the following amounts under other EPA regulations or state pro,ams authorized by EPA under 40 CFR Parts 271 and 145: EPA Reg~dations Amount Closure (§§ 264.143 and. 265.143)..: ................................ $ PostiClosure Care (§§ 264.145 and 265.145) ................... $ Liability Coverage (§ § 264.147 and 265.1.47) ................. Corrective Action (§ § 264.! 01 (b)) .................................. $ Plug~ng and Abandonment (§ 144.63) ........................... $ Closure .............. i .............................................................. $ Post-Closure care ............................................................ $ Liability Coverage ................. .....: ............................... :.,..$ Corrective Action ............................................................ $ Plugging and Abandonment ............................................ $ Total .................................... : ....................................... $ N/A N/A N/A N/A N/A N/A N/A 'N/A N/A' N/A N/A This "owner or operator," has not received an adverse opinion, a disclaimer of opinion, or a "going concern" qualification fi.om an independent auditor on his financial statements for the latest completed fiscal year. Letter from Chief Financial Officer Page 2 Alternative I i'. Amount of annual UST ·aggregate coverage being 'assured by a Financial test, and/or guarantee 2'. Amount of corrective .'action, closure and post-closure care costs, liability coverage, and plugging and abandonment costs' covered by a financial test, and/or guarantee $1Mi 3. Sum of Lines 1 and2 · 4. Total tangible assets 5. Total liabilities 2M 17.341 billion 13.574 billion 6. Tangible net worth 7. Is tine 6 at least $10 million?' 8. Is line 6 at least 10 times line 3? ' 3.767 billion Yes N_9 X X 9. Have financial statements for the latest · fiscal year been filed with the Securities and Exchange Commission? 10. Have financial statements for the latest fiscal year been filed with the Energy Information Administration? Have financial statements for the latest' fiscal year been filed with the Rural Electrification Administration? 12. Has financial information been provided to Dun and Bradstr'eet, and has Dun and Bradstreet provided a financial strength rating of 4A or 5A? X N/A N/A X I hereby certify that the wording of this letter is identical to the wording specified in 40 CFR Part, .280.95(d) as such regulations 'were constitufed on the date shown irmnediately below. On AprilffO, 2003 '('Signature) ~o 'h ' Vice President-Finance Pacific Bell/Nevada Bell LETTER FROM CHIEF FINANCIAL OFFICER I am the Chief Financial Officer for Pacific Bell, 2600' Camino Ramon, Room 4CN 100, San Ramon, California. This letter is in support of the use of the Underground Storage Tank Cleanup Fund to demonstrate financial responsibility for taking corrective action and/or compensating third parties for bodily injury and property damage caused by an unauthorized release of petroleum in the amount of at least $1,000,000 per occurrence and $ 2,000,000 annual aggregate coverage. Underground storage tanks at the following facilities are assured by this letter: A list of SBC facilities, name, address, number of tanks and size are listed in Exhibit "AY Amount of annual aggregate coverage being assured by this letter ............ : ......................................................... ...$ Total tangible assets ....................... ' .............. i ............... i ........ $ Tangible net worth (subtract line 3 from line 2. Line 4 must be at least 10 times line 1) ........ ....... i .... i..i ......... $ 2,000,000 million 17.341 billion 13.574 billion 3.767 billio'n I hereby certify that the wording of. this letter is identical to the wording specified in subsection 2508.1(d)(1), Chapter 18, Division 3, Title 23 of the California Code of Regulations, I declare under penalty of perjury that the foregoing is true and correct to the best of my knowledge and belief. Executed at. 175 E. Houstonl Room 1307, San Antonio, Texas 78205 On April 30, 2003 Susan Jo ,124.s)l~sj~-- n · Vi~'e Preside ~t~4~inance · Pacific Bell/Nevada Bell MONITI ING SYSTEM CERTIFICI . ION For Use By All durisdictions Within the State of California Authori~ Oted: Chapter 6. 7, Health and Safety Code: Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring eqmpment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A cop)' of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agent3~ regulating UST systems within 30 days of test date. A. General Information Facili~ Name: PACIFIC BELL GEO PAR # SA-098 CLLC Code: BI~DCAI4 Site Address: 3221 S. "H" STREET City: BAKERSFIELD Zip: Facility. Contact Person: HARRY DYCK Make/Model of Monitoring System: VEEDER ROOT TLS-350 B. Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment ins Tank ID: 333 []In-Tank Gauging Probe: Model: []Annular Space or Vault Sensor: Model: []Piping Sump/Trench Sensor (s): Model: []Fill Sump Sensor (s): Model: []Mechanical Line Leak Detector. Model: F1Electronic Line Leak Detector Model: []Tank Overfill/High-level Sensor: Model: Contact Phone No.: 619-696-0967 Date of Testing/Service: 4/16/03 847390-107 794390-420 794380-352 790091-001 I-lin-Tank Gauging Probe: Model: F1Annular Space or Vault Sensor Model: []Piping Sump/Trench Sensor (s): Model: F1Fill Sump Sensor (s): Model: []Mechanical Line Leak Detector. Model: []Electronic Line Leak Detector Model: []Tank Overfill/High-level Sensor: Model: []Other, Specify. equip, type and model in ,Section E on Page 2 Tank ID: [3In-Tank Gauging Probe: Model: F1Annular Space or Vault Sensor: Model: []Piping Sump/Trench Sensor (s): Model: FIFill Sump Sensor (s): Model: []Mechanical Line Leak Detector. Model: [2Electronic Line Leak Detector Model: FlTank Overfill/High-level Sensor: Model: · []Other, Specify equip, type and model in Section E on Page 2 Dispenser ID: []Dispenser Containment Sensor(s): Model: [] Shear Valve(s). []Dispenser Containment Boat(s) and Chain(s) Dispenser ID: [2Dispenser Containment Sensor(s): Model: [] Shear Valve(s). []Dispenser Containment Float(s) and Chain(s) Dispenser ID: [2Dispenser Containment Sensor(s): Model: [3 Shear Valve(s). [3Dispenser Containment Float(s) and Chain(s) V]Other, Specify equip, type and model in Section E on Page 2 Tank ID: [2In-Tank Gauging Probe: Model: IDAnnular Space or Vault Sensor Model: U1Piping Sump/Trench Sensor (s): Model: []Fill Sump Sensor (s): Model: [2Mechanical Line Leak Detector. -Model: []Electronic Line Leak Detector Model: []Tank Overfill/High-level Sensor: Model: []Other, Spec~, equip..type and model in Section E on Page 2 Dispenser ID: [3Dispenser Containment Sensor(s): Model: [] Shear Valve(s). []Dispenser Containment Float(s) and Chain(s) Dispenser IDi -- [3Dispenser Containment Sensor(s): Model: [3 Shear Valve(s). []Dispenser Containment Float(s) and Chain(s) Dispenser ID: []Dispenser Containment Sensor(s): Model: [] Shear Valve(s). []Dispenser Containment Float(s) and Chain(s) Page 1 of 3 03/01 *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary, to verify, that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): [] System set-up [] A! ' ton' report Technic/an Name (Print): DONS. THOMPSON Signature: .~_.,, ~_~'m ~kjtn_tA,,' Certification No.: ' 3354 License No.: 588098 Testing Company Name: TAIT ENVIRONMENTAL SYSTEMS Phone No.: (714) 560-8222 ~ected/serviced: Tank ID: Monitoring System Certification Site Address: 3221 S. "H" STREET, BAKERSFIELD D. Results of Testing/Servicing So/hvare Version Installed: 120.00 Date of Testing/Servicing: 4/16/03 Complete the following checklist: [] Yes [] No* Is the audible alarm operational? [] Yes [] No* Is the visual alarm operational? [] Yes [] No* Were all sensors vis. ually inspected, functionally tested, and confirmed operational? [] Yes [] No* Were all sensors installed at lowest point of seconda~ containment and positioned so that other equipment will not interfere with their proper operation? [] Yes [] No* ff alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) [] N/A operational? [] Yes [] No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment [] N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) [] Sump/Trench Sensors; [] Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks anti sensor failure/disconnection? [] Yes; [] No. [] Yes [] No* For tank systems that utilize the monitoring system as the prima~ tank overfill warning device (i.e. no [] N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at What percent of tank capacity does the alarm trigger? 95% [] Yes* [] No Was any monitoring equipment replaced? If yes, identify~ specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. [] Yes* [] No Was liquid found inside any seconda~, containment systems designed as dry systems? (Check all that apply) [] Product; [] Water. ffyes, describe causes in Section E, below. [] Yes [] No* Was monitoring system set-up reviewed to ensure proper settings? [] Yes [] No* Is aL1 monitorm~ equipment operational per manufacturer's specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: Page 2 of 3 03/Ol Site Address: 3221 S. "Iq' STREET, BAKERSFIELD Date of Testing/Servicing: 4/16/03 F. In-Ta'nk Gauging / SIR Equipment: [] Checl~' this boa ff tank gauging is used only for inventory control. [] Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: [] Yes [] No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? [] Yes [] No* Were all tank gauging probes visually inspected for damage and residue buildup? [] Yes [] No* Was accuracy of system product level readings tested? [] Yes [] No* Was'accuracy of system water level readings tested? [] Yes [] No* Were all probes reinstalled properly? [] Yes [] No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): [] Check this box if LLDs are not installed. Complete the following checklist: El Yes [] No* For ~quipment start-up or annual equipment certification, was a leak simulated t6 verify LLD performance? [] N/A (Check all that apply) Simulated leak rate: [] 3 g.p.h?; [] 0.1 g.p.h.2; [] 0.2 g.p.h.2 Notes: 1. Required for equipment start-up certification and annual certification. 2. Unless mandated by local agency, certification required only for electronic LLD start-up. [] Yes [] No* Were all LLDs confirmed operational and accurate within regulatory requirements? [] Yes [] No* Was the testing apparatus properly cahbrated? [] Yes [] No* For mechanical LLDs, does the LLD restrict product fl~)w if it detects a leak? [] N/A [] Yes [] No* For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? [] N/A [] Yes [] No* For electronic LLDs, does the turbine automatically shut off ff any portion of the monitoring system is disabled [] N/A or disconnected? [] Yes [] No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system [] N/A malfunctions or fails a test? . [] Yes [] No* For electronic LLDs, have all accessible wiring connections been visually inspected? [] N/A [] Yes [] No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these, deficiencies were or will .be corrected. H. Comments: Page 3 of 3 o3/ol Site Address:' 3221 S. "H" STREET, BAKERSFIELD Monitoring System Certification APR 1 6 2003 Date of Testing/Servicing: UST Monitoring Site Plan Date map was drawn~'~I (j6~0~3 Instructions If you already have a diagram that shows all required information, you may include it, rather than this page, with your Monitoring System Certification. On your site plan, show the general layout of tanks and piping. Clearly identify locations of the following equipment, if installed: monitoring system control panels; sensors monitoring tank annular spaces, sumps, dispenser pans, spill containers, or other secondary containment areas; mechanical or electronic line leak detectors; and in-tank liquid level probes (if used for leak detection). In the space provided, note the date this Site Plan was prepared. Page __ of__ 05/00 661 8@2-83?0 APR 16, 2008 10:21 SYSTEM 'STATUS REPORT ALL FUNCTIONS NORMAL · N?ENTOR¥, REPORT ._. T I:DIESEL 2333 . VOLUME' = 4288 GALS ULLAGE = ?48 GALS 90~ ULLAGE= .244 GALS TO VOLUME = 4267 GALS HEIGHT = 79.05 INCHES WATER VOL = 0 GALS WATER = 0.00 INCHES TEMP = 70.8 DEG F SYSTEM ~ETUP APR 16. 2008 10:21 SYSTEMUNI TS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM ~ATE/TIME' FORMAT SON DD YYYY HH:MM:SS xM PB BKFDOAI 4 8221 SOUTH H STREET B~K~BFIELD C~ 93304 66~ 8~-8S70 SHIFT TIME 1 ?:~O AM ~H;FT TIME 2 DISABLED SHIFT TI~ 9 DISABLED SH; FT T ~ ME 4 D ~ 8ABLED TA~ PER TST NEEDED W~N D ~ BABLED TANK ANN TST NEEDED WAN D ~ 8ABLED L ~ N~ RE-ENABLE M~T~D PASS, L I NE TEST L] NE [PE~ TST NEEDED WAN D I D ~ "7~' 7 g?' ~]: ~ ';';L ~ ~ -.:,.. . ..,;. - .::'~ ~:' ~, ;-:::!.' .. ..:: ;:.;' !' H-PROTOCOL DATA F~RMAT HEIGHT DAYLIGHT SAVING TIiME ENABLED START D~TE APR WEEK START TIME 2:00 AM END DATE OCT WE~K 6 SUN END TIME 2:00 ~ RE:DIRECT LOCAL P~INTOU~ DISABLED EURO PROTOCOL .: COMMON I CAT I ON~ sETuP PORT SETTINGS: OOMM BOARD 1 (F~MOD) BAUD RATE 12Q0 PARITY OPl~ . STOP BIT i ~TOP DATA LENGTH: 7 ~ATA RS-232 SECURITY CODE : ~ DIAL TYPE : TO~E AN~4ER ON : I RING MODEM SETUP STRIN~ : DIAL TONE INTERVAL: 82 RECEIVER SETUP: D I:EMCC 19268670241 RCVR TYPE: FAOS]MILE PORT I~: ! ' RETRY NO: 99 RETRY DELAY: lO CONFIRMATION REP?Ar: ON D 2:ALARM MONITO~II~G O0 171456082~7 RCVR TYPE: FACSiMiLE PORT NO: 1 RETRY NO: D I:EMCC DIAL ON DATE JAN 11, 2001 DIAL TIME : DISABLED RECEIVER REPORTS: SYSTEM STATUS PRIORITY HISTORY IN-TANK STATUS INVENTORY LEAK DETECT D 2:ALARM MONITORING CO DIAL ON DATE JAN Il, 2001 DIAL TIME : DISABLED RECEIVER REPORTS: SYSTEM BTAT~S : PRIORITY HISTORY : IN-TANK STATUS : INVENTORY : LEAK DETECT : RS-282 END OF MESSAGE DISABLED AUTO DIAL ALARM SETUP D 1: EMCC IN-TANK ALARMS ALL:LEMK ALARM ALL:HIGH WATER ALARM ALL:LOW PRODOCT ALARM ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ALL:WATER ALARM ALL:WATER OUT ALARM ALLtHIGH LIQUID ALARM ALL:LI~UID WARNIN~ D 2:ALARM MONITORING CO IN-TANK ALARMS ~LL;LEAK ALARM ALL:HIGH WATER ALARM ~LL:LOW PRODUCT AL~M /~,~:.':": [. ~...:.;:.", ,'.:':..;' ~'; ALL :WATER ALARM aLL:WATER OUT ALARM ALL:HIOH LIQUID ALARM ALL:LOW LIQUID ALARM ALL:LIQUID WARNING IN-TANK SETUP THERMAL COEFF ; .000450 TANK DIAMETER : 92,00 TANK PROFILE : 4 PTS FULL VOL : 5036 69.0 INCH VOL : 405! 46,0 INCH VOL : 2518 2~,0 INCH VOL ; 985 FLOAT SIZE: 4,0 IN, WATER WARNING : 1.0 HIGH WATER LIMIT: 1.5 MAX OR LABEL VOL: 5036 OVERFILL LIMIT : : 4532 HIGH'PRODOCT : 95~ : 4784 DELIVERY LIMIT : 70~ : 3525 LOW PRODUCT : 2500 LEAK ALARM LIMIT: 99 SUDDEN LOSS LIMIT: 99 TANK TILT : O.O0 M~NIFOLDED TANKS T~: NONE LE~K MIN PERIODIC: : 4028 LEAK HIN ~NNUaL : 80~ : 4028 PERIODIC'TEST TYPE STANDMRD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL RLMRM GROSS TEST FAIL DELIVERY DELAV : 5 ~tN "''~ LEAK TEST METHOl TEST CSLD : ~LL T~NK Pd = 95~ CLIMATE F~CTOR:I~ODER~TE TST E~RLY STOP:DISABLED LEaK TEST REPORT: ENHANCED LIaUID SENSOR SETUP L I:~NNUL~R TRI-STATE (SINGLE FLOmT) C~TEGORY : ANNULAR SP~CE L 2:SUMP SENSOR D l SORJM DUALcATEGORyFLT.: PIPI NG"SU~ OUTPUT RELAY S~TUP TYPE:RSTANDARDI:OVERFILL alARM NORMALLY OPEN IN-T~NK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM LIQUID SENSOR ALL:FUEL RL~RM ill. ~'! ~H" I. "9~ ~'!~ · ~: L ': :'. '. : · . '.. .,, : g F-.P',.b ca AUTOMATIC D~ILY CLOSING. TIME: 2:00 AM PERIODIC RECONCILIATION MODE: MONTHLY TEHP COMPENSATION STANDARD BUS SLOT FUEL METER TANK TANK MAP EMPTY SOFTWARE REVISION LEVEL VERSION 120.00 SOFTWARE~ 346120-100-A CRE~TED - 00.07.28.15,33 S-MODULE# 330160-002-A SYSTEM FEATURES: PERIODIC IN-TaNK TESTS ANNUAL IN-TANK TESTS CSLD ALARM HISTORY REPORT SYSTEM ALARM PAPER OUT FEB 14, 2003 7:30 AM PRINTER ERROR FE~ 19. 2003 8:4? A~ BATTERY I~ OFF J~N 1, 199g ~:00 ~M T 1 :DIESEL #S33 SETUP DAT~ WARNING JAN II. 2001 5:I9 PM OVERFILL ALARM APR 9, 2002 12:47 PM HIGH PRODUCT ALARM APR 16. 2003 iD:OS AM ~PR 9, 2002 12:47 PM JAN 11, 200! 5:21 PM PEOB~ OUT APB l&, 2D03 10:05 AM APR 9, 2002 12:49 PM APR 9, 2002 12:40 PM HIGH HATER WARNING JAN 11, 2001 5:2? PM JAN ti, 2001 5:22 PM DELIVERY NEEDED' JUN 20, 2002 11:11 AM APR 9, 2002 12:49 PM APR 9. 2002 12:40 PM M~× PRODUCT ALARM APR 16. 200S 10:05 AM APR 9. 2002 12:47 PM ALARM HISTORY REPORT 8EN~OR ALARM L 2:SUMP ~ENSOR PIPING SUmP HIGH LIqUiD ALARM APR 16. 2p03 10:07 AM NOV 26. 2p02 10:16 ~M HIGH LI~,ID ALARM APR 9. 2D02 12:~5 PM ALARM HISTORY REPORT ..... SENSOR ALARM L i:~NNULAR ANNULAR BPACE FUEL ALARM APR 16, 2003 10:07 AH FUEL ALARM NOV 26, 2002 10:17 AM FU~L ALARM Praxair Sc: ices, Inc. Technical Solutions for the Industrial World. UCISCO Tracer Research Corrocon Date: 5/05/03 Steve Underwood Bakersfield Fire Department Environmental Services 1715 Chester Ave. Bakersfield, CA 93301 661-326-3979 661-326-0576 Fax Re: Test Report - SBC Site - 3221 S. H STREET BAKERSFIELD, CA The attached report is for the completed Enhanced Leak Detection testing performed for SBC Communications. Tracer was detected in the backfill on this site. A tracer concentration of 0.035gg/L was measured in the sample collected from Probe 2. Probe 2 is installed to test the area at the top of the tank ridgeline and sumps. The concentration measured in the sample collected from within the Piping sump was at 0.069 Bg/L. This higher detection with in the sump is a strong indicator that the vapor release that is occurring is contained within the sump at a riser or piping connection. A helium investigation will be scheduled to locate the source for repair. Once repaired a retest will be performed with a new tracer. We will be working to expedite repairs and retest as soon as possible and will be contacting you with the schedule. If you have any questions regarding the testing and report, please do not hesitate to call me. Sincerely, Mark D. Caldon Project Manager Of: 520-888-9400 ext: 248 Fax: 520-293-1306 Cell: 620-432-5639 INFORMATION CONTAINED WITHIN IS CONSIDERED CONFIDENTIAL, PROPRIETARY INFORMATION OF PRAXAIR SER VICES, INC. KemCoverLetter 10 5. doc ~ILE THIS DOCUMENT IN THE O HAZARDOUS MATERIALS PLAN, PROGRAMS, PERMITS, and PLANS BINDER SECTION 3 UST Enhanced Leak Detection Test Report 2003 3221 S. H STREET (Facility Address) BAKERSFIELD (Facility City) KERN (Facility County) Maintain this UST Enhanced Leak Detection Test Report until replaced by a new test report. Testing Requirements: · Tri-annually on Standby Generator UST's that are not secondary containment tested ° When a new UST is installed THIS DOCUMENT IS REQUIRED TO BE POSTED ON SITE AND AVAILABLE FOR REVIEW BY GOVERNMENT AGENCY INSPECTORS, SITE ASSESSORS OR AUDITORS. THIS IS A CONDITION OF THE UST OPERATING PERMIT. Tracer Research C o r p o r a t i o n 3755 N. Business Center Drive Tucson, Arizona 85705 Toll Free (800) 989-9929 Tel: (520) 888-9400 Fax: (520) 293-1306 California Enhanced Tracer Tight® Leak Test April, 2003 Testing (1) Underground Storage Tank 3221 S. H STREET BAKERSFIELD, CA Tracer Job No. 30817U-0105 Prepared for: Stan Brodecki SBC Services Inc. 2600 Camino Ramon, Room 3E000K San Ramon, CA 94583 T~:925-823-6161 Fax: 925-867-0241 Site Location: CLLC# BKFDCA14 3221 S. H STREET BAKERSFIELD, CA Submitted by: Tracer Research Corporation Mark Caldon - Project Manager E-Mail: Mark Caldon~Praxair.com Website: h.t. tp :././www. TracerResearch. corn Installation & Inoculation By: Samples Collected By: Report Written By: Jim Cook - CA Tank Tester License # 03-1639 Brian Quinley - CA Tank Tester License # 03-1637 Mark Caldon - CA Tank Tester License # 92-1500 Site Location: 3221 S. H STREEII~ lq~[cer Job No.: 30817U-0105 Enhanced Leak Detection Testing Summary: Tank Piping Tracer System: Volume: Product: Type: Material: Material: Tracer: Detected: DW/Steel/Steel DW/Steel/Fiber Tank 333 5,000 ~lal Diesel UST/Pipin~; Clad glass A Fail Enhanced Leak Detection Testing Comments: Low level release of Tracer A detected in backfill - Most probable source in area of Piping Sump (TS 1). Tracer was detected in Probe 2 at 0.035 ug/L in the immediate area of the sump. The tracer concentration measured in the sample collected from the Piping sump was 0.069 ug/L. General Comments: Tracer distribution and concentrations are consistent with a vapor only release. Site Location: 3221 S. H STREE~ Job No.: 30817U-0105 Tank Piping Tracer System: Volume: Product: Type: Material: Material: Tracer: Detected: DW/Steel/Steel DW/Steel/Fiber Tank 333 5,000 gal Diesel UST/Piping Clad ,qlass A Fail Testin~ Events: ~ System Survey Information: Installation: 03/27/2003 Pump System Style: Suction Inoculation: 03/27/2003 Inventory Monitoring Method: ATG Sampling: 04/16/2003 Tank Innerstitial Sensors ? Yes Analysis: 04/23/2003 Tank Sump Sensors ? Yes Dispenser Containment ? No Installation Conditions: Dispenser Monitoring: N/A Backfill: Pea Gravel Vapor Recovery Style: N/A Ground Cover: Concrete/Asph Soil Permeability: >26.1 Darcys alt Water/Fuel: Reading: Fill Riser / Spill Bucket Test: Groundwater: >120" Test Duration: 180 rn in. Top of Tank: 43" Start Level: 3.50" Bottom of Tank: 134" End Level: 3.50" Product at Inoc: 78" Pass/Fail: Pass at Sampling: 76" water was placed in the spill containment bucket for ~wo hours- Fail = loss of water, Pass = no loss. Loss of water indicates faulty H20 at Inoc.: 0" drain valve or spill bucket/dssr connection. No inspection was at Sampling: 0" conducted to determine if loss impacted ~he backfill. Tank 333 - Data Analysis: Probe: A (l~j/L) ' I 0.000 2 0.035 3 0.000 4 0.000 ~5 , 0.000 ' i o.oooI Fl 0.000 I Ti1 i 0,000 iTS1 0.069 i IL ow level release of Tracer A detected in backfill - Most probable sourc~ in area of Piping Sump (TS1). Tracer was detected in Probe 2 at 0.035 ug/L in thc immediate area of thc sump. Thc tracer concentration measured in thc sample collected from thc Piping sump was 0.069 ug/L. Testim Events: Installation: 03/27/2003 Inoculation: 03/27/2003 Sampling: 04/16/2003 Analysis: 04/23/2003 System Survey Information: Pump System Style: Suction Inventory Monitoring Method: ATG Tank Innerstitial Sensors ? Yes Tank Sump Sensors ? Yes Dispenser Containment ? No Dispenser Monitoring: N/A Vapor Recovery Style: N/A Soil Permeability: >26.1 Damys Installation Conditions: Backfill: Pea Gravel Ground Cover: Concrete/Asph alt Water/Fuel: Reading: Groundwater: >120" Top of Tank: 43" Bottom of Tank: 134" Product at Inoc: 78" at Sampling: 76" H20 at Inoc.: 0" at Sampling: 0" Fill Riser / Spill Bucket Test: Test Duration: 180 rn in. Start Level: 3.50" End Level: 3.50" Pass/Fail: Pass Water was placed in the spill containment bucket for ~wo hours - Fail = loss of water, Pass = no loss. Loss of water indicates faulty drain valve or spill bucket/dser connection. No inspection was conducted to determine if loss impacted ~he backfill. Tank 333 - Data Analysis: Probe: A (I~/L) 1 0.000 2 0.035 3 0.000 4 0.000 5 0.000 6 0.000 F1 0.000 TI1 0.000 TS1 0.069 site Location: 18-5' P1 T1 A, B, R, W TVHC mg/L ATG1 F1 FVRS1 PI1 TI1 TS1 VR1 3221 S. H STREI ~cer Job No.: 30817U-0105 EXPLANATION OF ABBREVIATIONS Probe-Depth'. The number before the hyphen gives the location number of the probe from which the sample was collected. The location of the given probe is given on the accompanying map, usually Figure 1. The number after the hyphen gives the depth, usually in feet, at which the sample was collected. The apostrophe indicates that the depth is in units of feet. Piping Trench 1. Indicates the beginning of a section in which the listed results that follow are associated with the piping at the facility. Tank 1. Indicates the beginning of a section in which the listed results that follow are associated with tank number one. Tracer. Each tracer chemical used during the test is identified with a letter designator. Micrograms per Liter. Tracer concentrations are listed in units of micrograms per liter. Total Volatile HydroCarbons. The concentration of hydrocarbon vapors is determined for each sample. Milligrams per Liter. The concentration of hydrocarbon vapors present in each sample is listed in units of milligrams per liter. Automatic Tank Gauge, Tank 1. A sample with this designator was collected below the manhole cover and outside the access riser for the automatic tank gauge. Fill, Tank 1. A sample with this designator was collected inside the spill bucket at the fill riser. Fill-Vapor-Recovery-Riser Sump, Tank l. A sample with this designator was collected from the sump containing the fill riser and the vapor recovery riser. The sample was collected below the spill buckets. Pipe Interstice, Tank l. A sample with this designator was collected between the primary and secondary containment walls of the double walled piping. The piping interstice is accessed inside the turbine sump. Tank Interstice, Tank l. A sample with this designator was collected inside of and at the bottom of the access riser for the space between the primary and secondary containment walls of the tank. Turbine Sump, Tank l. A sample with this designator was collected from inside the turbine sump. Vapor Recovery, Tank 1. A sample with this designator was collected inside the spill bucket at the Stage I vapor recovery riser. Site Location: 3221 S. H STREi~ i~cer Job NO.: 30817U-0105 SITE MAPS Sampling Location Figure 1 Tank 1 5,000 gal Diesel Tracer [A] Parking Lot I°5 Driveway EXPLANATION .1 File = SBC105-1 Arc: SBCL05-1 Sampling Probe Location Approximate Pipeline Location size:A Date:04-07-03 0 10 f e e 2O S B C Building SITE% 105 GEO PAR# SA098 TRC JOB9 30817U-105 S B C S E RV I C E S C L L C # B K F D C A 1 4 3 2 21 s. B STREET BAKERSFIELD, CALIFORNIA SAMPLING LOCATIONS Figure 1 Site Location: 3221 S. H STREI~ ~cer Job No.: 30817U-0105 FIELD DOCUMENTATION Inoculation Form Sampling Chain Of Custody Forms L_SBC-3221 S. H STREET, BAKERSFIELD, C I SBC-BKFDCA14 - Inoculation F6~-. Address: 3221 S. H STREET USA State: CA Zip: Source: DataTmce 2.0 TRC Cans Ingress: Probe List: I System Number / Name: V°lume:ProduCt: Type: l Dia: Lett: ltgt: BTDp PRLv Tt4q. v GfftDp ] Fuel [ (gallora) (ln feet) (in inches) Rcvd TPF TRC Lbs. I Ill Fac: El05 Facility El05 Address: BKFDCAI4 laoc. Date: 333 I Tank 333 5,0001Diesel Test: A t~ Tigh~ess Test rents: (lYo§e Replacements Needed 7, Di~ t'¢f~l~ l~qliO~ted ~.) .. ' tnocut~on Confirmed dation Form: SBC-3221 S- H STREET (30817U-0105i l, Tracer Research Corporation Job No. 30817U-0105 Period: 01-30-2003 SBC-3221 S. H STREET, BAKERSFIELD, C Chain of Custody I Sampling Instructions City: BAKERSFIELD State: CA Zip: CLLClt: SBC-BKFDCA14 GeoPar: SA098 Pro sour=e: DataTrace 2.0 ~ Facility:. i System: ] Collector: otlt: P r o b e (s): Depth: Cover: Vacuum: PRLv TWLv Date/Time: Comments: Compound: AnDate: SF: Sample ~ El05 i 333 ]AirBlank 1 AIR001 / iAir i./ i i7/~/~! A, tvhc iq/~/~t~ li EI05_AIR001 -- A: Tightness Test i Tank 333 A: Tightness Test ] Tank 333 Tank 333 4 El05 333 Individual I 3 ~ ~ ~ : ~ ~ A, tvhc ~ 1~ El05 A: Tightne~ Test ~ Tank ~3 S El05 333 ~ ludividual 1 4 2 ~ A, Whc 1 ~ El0[4 A: Tightness Test l Tank 333 i ~ ~ ~ { ~--~:. [ I ~ ~ El05 333 Individual 1- ' A, tvhc r El05 ~ 333 Individual I 6 A, tvhc 1 Tank 333 ~ ~ -- A: Tightness Test ~ Tightness Test Tank 333 ~ ~ , '~{ ~ El05 333 Individual I A, Whc E105_8 _ ~ ~ghtness Test Tank 333 ~0 El05 ~ 333 Individual I A, Whc I ~ EI05~ A: Tig~ness TestTank 333 ~a El05 333 Iudividual I A, tvhc ~ I EI0~I0 ~ ~ Tightness TestTank 333 ~= El05 333 Individual I ~, Whc I [105_1 A: Tig~ness TestTank 333 ,~ ~105 333 Individual I A, Whc A: Tightness Test Tank 333 ~ ~'~ ' ~i~ ~4 [105 ~ 333 ' ludividual 1 A, Whc ~ ~' ~ - A: Tightne~ Test Tank 333 A: Tightness T~st Tank 333 ~~ ~S El05 333 Individual 1 ~ ~ Tightness Test Tank 3~ A: Tightness Test Tank 333 ~ ~ . : : . . , ~ E105 333 I Individual I FI ~ ~g~ess Test Tank 3~ . : -- El05 ~ 333 Individual/ TII ~. 19 A: Tightne~ Test Tank ~3 ~ TightnessTestE105 ~mank~3 ~ :: ~~ ~:. : ~ A, Whc ~~ I ~ EI0~TS1 2o : : i I Chain of Custody Form: sac-3z21 s.. sI~gI O0SlTv-0105) I /~ I~"m"" .... -- '.APR-16-2003 ll: 06 ENU I RONMENTAL MGMT 925 869 024i SBC ENVIRONMENTAL MANAGEMENT PACIPIC REGION FACSIMILE TRANSMITTAL SHEET TO: FROM; Steve Underwood Armi D. Stricldand COMPANY: DATE: Ba&ers~dd Fire Dept 04/16/03. FAX NUMBEP.~,;~' TOTAL NO. O1~ PAGES INCLUDING COWER; (661)4~2-~172 3 PHONE NUMILER: SENDER'S KEP£RRNCR N~MBERr RE: YOUR REFERENCE Iq-kTMBER~ URGENT X i~OR REVIEW ' PLEASE COMMENT [] PLEASE REPLY NOTES/COMMENTS., [] ~'LEAS. ~ ~,I~CYCLE Per your request, attached is the Monitoring Ce-,ffication Alarm History for the Pacific Bell location at 3221 South H Street, Bakersfield. Armi Strickland 2600 CAMINO RAMON, ROOM )E000~I SAN i%AMON, CA (800) 757-6575 (9:~ S) e2~.Sga:~/OFP]CE (925) 867-0241/FAX AD327S~$~,C,GOM APR-16-20~ 11:~ ENUIRONMENTAL MGMT 925 ~? 0241 P.02/B3 · 'GLANCE1101 · 9999FF10Bo0,OLANCEI10100, Il0100 APR 16, 2003 10;27 AM PB BKFEK2AI4 SA.098 3221 SOUTH H STREET BAKF. RSFIELD CA 93304 661 832-8370 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL · ,OLANCEI30200, I30200 APR 16, 2003 10:28 AM PB BKFDCA14 SA-098 3221 SOUTH H STREET BAKF. RSFIELD CA 93304 66I 832-8370 UQUID ALARM HISTORY REPORT SENSOR LOCATION 1 ANNULAR APR 16, 200.3 10:07 AM NOV 26, 2002 10:17 AM APR 9, Z002 12;37 PM 2 SUMP SENSOR APR 16, 2003 10:07 AM · NOV 26, 2002 10:16 AM APR 9, 2002 12:35 PM FUEL ALARM FUEL ALARM FUEL ALARM HIGH LIQUID ALARM LIQUID WARNING HIGH LIQUID ALARM PBBKFDCA14SA.098 3221SOUTHHSTREBT BAKERSMBLDCA93304 661 832-8370 TANK ALARM HISTORY TANK I DIESEL #333 SETUP DATA WARNING OVERFILL ALARM JAN 11, 2001 5:19 PM APR 9, 2002 12:47 PM ENUIROHMENTAL MGMT 925 869 0241 P.03/03 HIGH PRODUCT ALAR2v[ APR 9, 2002 JAN 11, 2001 APR 16, 1003 10:05 AM 12:47. PM $;21 PM PROBE OUT APR 16, 2003 10;05 AM APR 9, 2002 12;49 PM APR 9, 2002 12:40 PM HIGH WATER WARNINO JAN 11,200I 5:27 PM JAN I1, 2001 5:22 PM DlliLIVBRY NEEDED JUN 20, 2002 11:11 AM APR 9, 2002 12:49 PM APR 9, 2002. 12:40 PM MAX PRODUCT ALARM APR 16, 2003 10:05 AM APR 9, 2002 12:47 PM TOTRL P. 0~ CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3rd Floor, Bakersfield, CA 93301 FACILITY NAME PO, Ct ADDRESS .~-~{ '~ FACILITY CONTACT INSPECTION TIME INSPECTION DATE qlt lO PHONE NO, '3¢g BUSINESS ID NO. 15-210- NUMBER OF EMPLOYEES,., Section 1: Business Plan and Inventory Program Routine ~ Combined [~ Joint Agency ~ Multi-Agency ~ Complaint [~ Re-inspection OPERATION C V COMMENTS Appropriate permit on hand Business plan contact information accurate La Visible address Correct occupancy Verification of inventory materials Verification of quantities Verification of location Proper segregation of material Verification of MSDS availability Verification of Haz Mat training Verification of abatement supplies and procedures Emergency procedures adequate c'" Containers properly labeled Housekeeping Fire Protection ~. , Site Diagram Adequate & On Hand C=Compliance V=Violation Any hazardous waste on site?: ~] Yes ~] No Explain: Questions regnrding this inspection? Please call us at (661 ) 326-3979 White - Env. Svcs. Yellow - S~ation Copy Pink - Business Copy FACILITY NAME CITY OF BAKERSFIEI,D FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CItECKLIST 1715 Chester Ave., 3ra Floor, Bakersfield, CA 93301 Section 2: Underground Storage Tanks Program [] Routine ~ Combined [] Joint Agency Type of Tank Type of Monitoring [] Multi-Agency. [~1 Complaint Number of Tanks [ Type of Piping ~Wl~' Re-inspection OPERATION C V COMMENTS / Proper tank data on tile ~.,./ Proper owner,!operator data on file ~,~ Permit lees current L,,,, /. Certification of Financial Responsibility '~ /, Monitoring record adequate and current /,, Maintenance records adequate and current Failure to correct prior UST violations Has there been an unauthorized release? Yes No Section 3: Aboveground Storage Tanks Program TANK SIZE(S) AGGREGATE CAPACITY Type of Tank Number of Tanks OPERATION Y N COMMENTS SPCC available SPCC on file with OES Adequate secondary protection Proper tank placarding/labeling Is tank used to dispense MVF? If yes, Does tank have overfill/overspill protection'.> C=Compliance Z~/=Violati(2n Y=Yes Office of Environmental Services (661) 326-3979 N=NO White - Env. Svcs. Pink - Business Copy B u~ i~e-s s/~te R/ponsible 'P~a(-[y January 22, 2003 FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES 2101 "H' Street Bakersfield. CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 SUPPRESSION SERVICES 2101 'H' Street Bakersfield. CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 PREVENTION SERVICES FIRE SAFE*'Ff SERVICES * EHVIRONUrI~AL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 326-0576 PUBLIC EDUCATION 1715 Chester Avb. Bakersfield, CA 93301 VOICE (661) 326-3696 FAX (661) 326-O576 FIRE INVESTIGATION 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 326-0576 TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 pacific Bell 3221 South H Street Bakersfield CA 93304 RE: Upgrade Certificate & Fill Tags Dear Owner/Operator: Effective January 1, 2003 Assembly Bill 2481 went into effect. This Bill deletes the requirement for an upgrade certificate of compliance (the blue sticker in your window) and the blue fill tag on your fill. You may, if you wish, have them posted or remove them. Fuel vendors have been notified of this change and will not deny fuel delivery for missing tags or certificates. Should you have any questions, please feel free to call me at 661- 326-3190. Sincere~ ~ Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/dc B L D December I, 2002 FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES - - - 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 PREVENTION SERVICES FIRE SAFETY SERVICES · ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 326-0576 PUBLIC EDUCATION 1715 Chester Arb, Bakersfield, CA 93301 VOICE (661) 326-3696 FAX (661) 326-0576 FIRE INVESTIGATION 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 326-0576 TRAINING-DIVISION 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 Pacific Bell 3221 South H Street Bakersfield CA 93304 CERTIFIED MAIL FINAL REMINDER NOTICE JANUARY 1, 2003 DEADLINE Dear Tank Owner/Operator: You will be receiving this letter on or about December 1, 2002. One month from today, January 1, 2003, your current underground storage tank(s) will become illegal to operate. Current law would require that your permit be revoked for failure to perform the necessary Secondary Containment testing. In reviewing your file, I see that you have received "Reminder Notices" since April of this year. This is your last chance to comply with code requirements for Secondary Containment testing prior to January I, 2003. Should you have any questions, please feel free to contact me at 661- 326-3 !90. - Sincer~.~:~~ Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services, SBU/dc S~B0'~'~0'~6~0L ~d!aoaB 0000 09~20 200~ ON [] :/~oleq sseJppe fue^!lap Je)ue 'SaA il sea O 8 L ~e3! ~04 lueJe~!p ~eJppe ~eA!lep si 'Q I ~eA!leQ Jo e~eO 'O ~ (e~eN pe~u!Jd ).~q peA~eoe~ 'B eesseJppv ~ ~ ~ X ~ue6v 0 '1 :o3 pesseJppv elo!Pv ' L · sl!tuJed eoeds j) luoJJ eq), uo Jo 'eoeidlleLU eq), ~o ~loeq eq) o) pJeo s!ql qoei4¥ · · no/[ o) pJeo eq) uJnieJ ueo e~A )eq) OS esJe^eJ eq~ uo sseJppe pue eLUeU Jno~ )upd · · peJlsep si /aeAlleO pe~oiJlsebt ¢! 1~ LUe~) elelduJo00SlV 'g pu~ '~ ' [ SLUe~! eleldLUoO · C AL C::3 Po~tage $ ~ [:3 ~ r--~ Certified Fee Postmark [::3 Retum Receipt Fee _n (Endorsement Required) Here ~3 Restricted Delivery Fee [::3 (Endorsement Required) nj 1 ~1~ PACIFIC BELL ~' r'-b 3221 SOUTH H STREET [!! BAKERSFIELD CA 93304 ................. ................. December 1, 2002 FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 PREVENTION SERVICES FIRE SAFE~f SERV1CES * ENVIRONMENTAL SERY~E$ 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 326-0576 PUBLIC EDUCATION 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3696 FAX (661) 326-0576 FIRE INVESTIGATION 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 326-0576 TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 Pacific Bell 3221 South H Street Bakersfield CA 93304 CERTIFIED MAIL FINAL REMINDER NOTICE JANUARY 1, 2003 DEADLINE Dear Tank Owner/Operator: You will be receiving this letter on or about December 1, 2002. One month from today, January 1, 2003, your current underground storage tank(s) will become illegal to operate. Current law would require that your permit be revoked for failure to perform the necessary Secondary Containment testing. In reviewing your file, I see that you have received "Reminder Notices" since April of this year. This is your last chance to comply with code requirements for Secondary Containment testing prior to January 1, 2003. Should you have any questions, please feel free to contact me at 661- 326-3 ! 90. Sincerely, ~ .. Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SBU/dc · ' items 1, 2, and 3. Aisc complete item 4 if Restricted Delivery is desired. · Print your name and address on the reverse so that we can return'the card to you. '· Attach this card to the back of the mailpiece, or on the front if space permits. 1. Article Addressed to: PACIfiC BELL 3221 SOUTH H STREET BAKERSFIELD CA 93304 ' L.fl ~,ddressee I B. Received y ( ~d l ame) i'¢at~De~l D. Is delivery address different from item 17 ,,~ Yes If YES, enter delivery address below: ~l, No /\ 700.2 0860 ' PS Form 3811, August 2001 3. Service Type I~ Certified Mail [] Express Mail [] Registered [] Return Receipt for Merchandise [] Insured Mail [] C.O.D. 4. Restricted Delivery? (Extra Fee) [] Yes 0000 1641 6926 Domestic Return Receipt 102595-02-M~08351 BAkeRSFIELD FIRE DEPART~,~ENT OFFiCe' OF ENVIRONMENTAL SERVICES 1715 Chgster Avenu3, Suite 300 Bak~rsfi~)d, CA 93301 Postage $ Certified Fee Postmark Return Receipt Fee ~ndo~ment Requim~ Hem Re~rict~ ~live~ F~ (Endowment R~ui~ Sent T° PACZFIC BELL ~i;;;i;~Z"~&; ............................................................................. ~:~:~.~:.~:: ........ ~.~.L~.s...~...~m~.~. ............................... ~ ~'~ JCt~S~e, ztP+4 B~FIE~ CA 93304 October 31. 2002 Pacific Bell 3221 South H Street Bakersfield CA 93304 CERTIFIED MAIL REMINDER NOTICE FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES 2101 "H' Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 SUPPRESSION SERVICES 2101 'H' Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 PREVENTION SERVICES FtRE SAFETY 5~:FNICE$ 1715 Chester Ave. Bakemfie~, CA VOICE (~1) 326-3979 F~ (~1) 32~576 PUBLIC EDUCATION 1715 Chester Av~. Bakersfield, CA 93301 VOICE (661) 326-3696 FAX (661) 326-0576 FIRE INVESTIGATION 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 3264)576 TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 RE: Necessary secondary containment testing requirements by December 31, 2002 of underground storage tank (s) located at the above stated address. Dear Tank Owner / Operator, If you are receiving this letter, you have not yet completed the necessary secondary containment testing required for all secondary containment components for your underground storage tank (s). Senate Bill 989 became effective January 1, 2002, section 25284.1 (California Health & Safety Code) of the new law mandates testing of secondary containment components upon installation and periodically thereafter, 'to insure that the systems are capable of containing releases from the primary containment until they are detected and removed. Of great concern is the current failure rate of these systems that have been tested to date. Currently the average failure rate is 84%. These have been due to the penetration boots leaking in the turbine sump area. For the last six months, this office has continued to send you monthly reminders of this necessary testing. This is a very specialized test and very few contractors are licensed to perform this test. Contractors conducting this test are scheduling approximately 6-7 weeks out. The purpose of this letter is to advise you that under code, failure to perform this test~ by the necessary deadline~ December 31~ 2002~ will result in the revocation of your permit to operate. This office does not want to be forced to take such action, which is why we continue to send monthly reminders. Should you have any questions, please feel free to call me at (661) 326-3190. Sincere~ ~, Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services P. 05 CITY' OF BAKERSFIELD OFFICE OF ENVIRONMENTAL SERVICES 171S Chester Ave., Bakersfield, CA (661) 326-3979 APPLICATION TO PERFORM A TANK TIGHTNESS TEST/ SECONDARY CONTAINMENT TESTING/TRACER TESTING ~o~s]-~ __~-/' £. TOTP~_ P. I~ ADDRESS 3~.1 ,q, ' .~" FACILITY CONTACT INSPECTION TIME CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3~d Floor, Bakersfield, CA 93301 INSPECTION DATE PHONE NO. 3~~ qt BUSINESS ID NO. 15-210- NUMBER OF EMPLOYEES Section 1: Business Plan and Inventory Program Routine ~ Combined ~ Joint Agency [~ Multi-Agency ~ Complaint I~ Re-inspection OPERATION C V COMMENTS Appropriate permit on hand ~ f Business plan contact information accurate L./ Visible address I., / Correct occupancy L / Verification of inventory materials ~.J Verification of quantities ~.J Verification of location ~ j Proper segregation of material ~.,,~ Verification of MSDS availability ~ ~ Verification of Haz Mat training ~.,~ Verification of abatement supplies and procedures ~ ~ Emergency procedures adequate L,~ Containers properly labeled /~~' Housekeeping ,~ Fire Protection L~ Site Diagram Adequate & On Hand c~ C=Compliance V=Violation Any hazardous waste on site?: [~ Yes a No Explain: Questions regarding this inspection? Pleas~ call us at (661) 326-3979 White - Env. Svcs. Yellow - Station Copy Pink - Business Copy CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3rd Floor, Bakersfield, CA 93301 FACILITY NAME P~t~t-~ Section 2: Underground Storage Tanks Program [~1 Routine [~Combined [] Joint Agency Type of Tank O/L)l-~-t'_ Type of Monitoring INSPECTION DATE I O 'L [] Multi-Agency. I~[ Complaint Number of Tanks [ Type of Piping /:bO/= [] Re-inspection OPERATION C V COMMENTS tank data on file Proper Proper owner/operator data on file Permit fees current [~, Certification of Financial Responsibility Monitoring record adequate and current Maintenance records adequate and current Failure to correct prior UST violations Has there been an unauthorized release? Yes No Section 3: Aboveground Storage Tanks Program TANK SIZE(S) AGGREGATE CAPACITY Type of Tank Number of Tanks OPERATION Y N COMMENTS SPCC available SPCC on file with OES Adequate secondary protection Proper tank placarding/labeling Is tank used to dispense MVF? tf yes, Does tank have overfill/overspill protection? t' C=Compliance / V=Vi01ation Y=Yes N=NO Inspector: ,.~ ~~ Office of Environmental Services (805) 326-3979 White- Env. Svcs. September 30, 2002 Pacific Bell 3221 South H Street Bakersfield CA 93304 FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES 2101 "H' Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 PREVENTION SERVICES FIRE SAFETY SERVICES · ENVIRONMENTAl. SERI~CES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 326-0576 PUBLIC EDUCATION 1715 Chester Bakersfield, CA 93301 VOICE (661) 326-3696 FAX (661) 326-0576 FIRE INVESTIGATION 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 326-0576 TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 REMINDER NOTICE RE: Necessary secondary containment testing requirements by December 31, 2002 of underground storage tank (s) located at the above stated address. Dear Tank Owner / Operator, If you are receiving this letter, you have no.~t yet completed the necessary secondary containment testing required for all secondary containment components for your underground storage tank (s). Senate Bill 989 became effective January 1, 2002, section 25284.1 (California Health & Safety Code) of the new law mandates testing of secondary containment components upon installation and periodically thereafter, to insure that the systems are capable of containing releases from the primary containment until they are detected and removed. Of great concern is the current failure rate of these systems that have been tested to date. Currently the average failure rate is 84%. These have been due to the penetration boots leaking in the turbine sump area. For the last five months, this office has continued to send you monthly reminders of this necessary testing. This is a very specialized test and very few contractors are licensed to perform this test. Contractors conducting this test are scheduling approximately 6-7 weeks out. The purpose of this letter is to advise you that under code, failure to perform this test, by the necessary deadline, December 31, 2002, will result in the revocation of your permit to operate. This office does not want to be forced to take such action, which is why we continue to send monthly reminders. Should you have any questions, please feel free to call me at (661) 326-3190. Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services D August 30, 2002 Pacific Bell 3221 S. "H" Street Bakersfield, CA 93304 REMINDER NOTICE FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 vOICE (661) 326-3941 FAX (661) 395-1349 PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 326-0576 ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 326-0576 TRAINING DIVISION 5642 Victor Ave. Bakersfield. CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 RE: Necessary secondary containment testing requirements by December 31, 2002 of underground storage tank (s) located at the above stated address. Dear Tank Owner / Operator, If you are receiving this letter, you have not yet completed the necessary secondary containment testing required for all secondary containment components for your underground storage tank (s). Senate Bill 989 became effective January 1, 2002, section 25284.1 (California Health & Safety Code) of the new law mandates testing of secondary containment components upon installation and periodically thereafter, to insure that the systems are capable of containing releases fi.om the primary containment until they are detected and removed. Of great concern is the current failure rate of these systems that have been tested to date. Currently the average failure rate is 84%. These have been due to the penetration boots leaking in the turbine sump area. For the last four months, this office has continued to send you monthly reminders of this necessary testing. This is a very specialized test and very few contractors are licensed to perform this test. Contractors conducting this test are scheduling approximately 6-7 weeks out. The purpose of this letter is to advise you that under code, failure to perform this test, by the necessary deadline, December 31, 2002, will result in the revocation of your permit to operate. This office does not want to be forced to take such action, which is why we continue to send monthly reminders. Should you have any questions, please feel free to call me at (661) 326-3190. Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services D July 30, 2002 Pacific Bell 3221 So H Street Bakersfield CA 93304 FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES 2101 "H' Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 SUPPRESSION SERVICES 2101 "H' Street Bakersfield, CA 93.,c~1 VOICE (661) 326-3941 FAX (661) 395-1349 PREVENTION SERVICES FIRE SAFETY SERVICES · ENVIRONMENTAL SERT~ICE$ 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 326-0576 PUBLIC EDUCATION 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3696 FAX (661) 326-0576 FIRE INVESTIGATION 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 326-0576 TRAINING DlVlSION 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 REMINDER NOTICE RE: Necessary Secondary Containment Testing Requirements by December 31, 2002 of Underground Storage Tank (s) Located at the Above Stated Address. Dear Tank Owner / Operator: If you are receiving this letter, you have not yet completed the necessary secondary containment testing required for all secondary containment components for your underground storage tank (s). Senate Bill 989 became effective January 1, 2002, section 25284.1 (California Health & Safety Code) of the new law mandates testing of secondary containment components upon installation and periodically thereafter, to insure that the systems are capable of containing releases from the primary containment until they are detected and removed. Of great concern is the current failure rate of these systems that have been tested to date. Currently the average failure rate is 84%. These have been due to the penetration boots leaking in the turbine sump area. For the last four months, this office has continued to send you monthly reminders of this necessary testing. This is a very specialized test and very few contractors are licensed to perform this test. Contractors conducting this test are scheduling approximately 6-7 weeks out. The purpose of this letter is to advise you that under code, failure to perform this test, by the necessary deadline, December 31, 2002, will result in the revocation of your permit to operate. This office does not want to be forced to take such action, which is why we continue to send monthly reminders. Should you have any questions, please feel free to call me at (661) 326-3190. Sincerely~/ Steve Underwood Fire Inspector Environmental Code Enforcement Officer SBC jI~ILE HAZARDOUS MATERIALS PLANS PROGRAMS PERMITS BINDER SECTION 1 Hazardous Materials Annual InVentory YEAR 2002 Pacific Bell - SA098 (Facility Name and ID) 3221 S. H STREET (Facility Address) · BAK~RSnELD (Facility City) (Facility County) POST THIS DOCUMENT ON SITE SO IT WILL BE AVAILABLE IN THE EVENT OF A GOVERNMENT AGENCY INSPECTION, SITE ASSESSMENT OR AUDIT. Rev, 11/09/2001 (jsb) ~IFIED PROGRAM CONSOLIDATED BUSINESS ACTIVITIES FACILITY INFORMATION Page I of~ I. FACILITY IDENTIFICATION !FACILITY ID# BUSINESS NAME (Same as FACILITY NAME or DBA-Doing Business AS) I I EPA ID# (Hazardous Waste Only) I C^TO80020514 Pacific Bell SA098 3221 S. H STREET BAKERSFIELD I. ACTIVITIES DECLARATION NOTE: If you check YES to any part of this list, please submit the Business Owner/Operator Identification page (OES Form 2730). Does your facility... If Yes, please complete these pages of the UPCF... A. HAZARDOUS MATERIALS Have on site (for any purpose) hazardous materials at or above 55 gallons for liquids, 500 pounds for solids, or 200 cubic feet for compressed gases (include liquids in ASTs and USTs); or the applicable Federal threshold quantity for an extremely hazardous substance specified in 40 CFR Part 355, Aappendix A or B; or handle radiological materials in quantities for which an emergency plan is required pursuant to 10 CFR Parts 30, 40 or 70? B. UNDERGROUND STORAGE TANKS lUSTs) 1. Own or operate underground storage tanks? 2. Intend to upgrade existing or install new USTs? r~--]YES [] NO 4 r-~YES [] NO 5 C. ABOVE GROUND PETROLEUM STORAGE TANKS fASTs) Own or operate ASTs above these thresholds: --any tank capacity is greater than 660 gallons, or --the total capacity for the facility is greater than 1,320 gallons? Need to report closing a UST? E~] D. HAZARDOUS WASTE 1. Generate hazardous waste? 2. Recycle more than 100 kg/month of excluded or exempted recyclable materials (per HSC ~ 25143.2)? 3. Treat hazardous waste on site? Treatment subject to financial assurance requirements (for Permit ~'-~ YES r~NO 6 YES [] NO 8 YES ~-~ NO*9 YES F~NOlO YES r~---] NO 11 ~-~ YES ~NO12 by Rule and Conditional authorizaton)? Consolidate hazardous wa~ste generated at a remote site? Need to report the closure/removal of a tank that was classified as hazardous waste and cleaned onsite? ~-~ YES F~--']NO 13 ~--] YES F~NO 14 HAZARDOUS MATERIALS INVENTORY - CHEMICAL DESCRIPTION (OES 2731) UST FACILITY (Formerly SWRCB Form A) UST TANK (One page per tank) (Formerly Form B) UST FACILITY UST TANK (One per tank UST INSTALLATION - CERTIFICATE OF COMPLIANCE(one page per tank)(Formedy Form C) UST TANK (closure portion-one page per tank) NO FORM REQUIRED TO CUPAS EPA ID NUMBER-provide at the top of this page RECYCLABLE MATERIALS REPORT (one per recycler) ONSITE HAZARDOUS WASTE TREATMENT - FACILITY (Formerly DTSC Form 1772) ONSITE HAZARDOUS WASTE TREATMENT'UNIT(one page per unit) (Formerly DTSC Form 1772A,B,C,D, and L) CERTIFICATION OF FINANCIAL ASSURANCE (Formerly DTSC Form 1232) REMOTE WASTE/CONSOLIDATION SITE ANNUAL NOTIFICATION (F0rmedy DTSC Form 1232) HAZARDOUS WASTE TANK CLOSURE CERTIFICATION (Formerly DTSC Form 1249) LOCAL REQUIREMENTS 15 fou may also be required to provide additional information by yourCUPA or local agency.) UPCF (1/99) 2 CONSO', AT , BUSINESS OWNER/OPERATOR IDENTIFICATION FACILITY INFORMATION page 7_ of ~ iF^~.ILITY ID# iBUSINESS NAME I. IDENTIFICATION I;~ii [i'~i~t ! , BEGINNING DATE I~!~it li¢i::!~ 12/1/2001 (Same as FACILITY NAME or DBA - Doin8 Business As) Pacific Bel~ SA098 [BUSINESS SITE ADDRESS 3221 S. H STREET 104 CA ' ZIP CODE 106 SIC CODE ]CITY ! BAKERSFIELD :,DUN BRADSTREET 10-340-i618 lOO ENDING DATE 101 12/1/2002 BUSINESS PHONE 102 661-398-4185 103 105 93304 (4 digit #) 107 4811 ~COUNTY 108 KERN · !BUSINESS OPERATORHARRyNAME DYCK lO9 BUSINESS OPERATOR559-454.3003PHONE 110 II. BUSINESS OWNER 111 OWNER PHONE 112 OWNER NAME Pacific Bell 877-823-9833 OWNER MAILING ADDRESS '113 2600 CAMINO RAMON, RM 3E000 CITY SAN RAMON 114 STATE 115 ZIP CODE 116 CA 94583-0995 IlL ENVIRONMENTAL CONTACT i CONTACT NAM E ,-,r,~,-,,/ 117 CONTACT PHONE 118 STAN BRuu,-~r4 925-823-6161 Ir ' '~CT MAILING ADDRESS 119 '!: 2600 CAMINO RAMON, RM 3E000 ~CITY 120 STATE 121 ZIP CODE 122 i SAN RAMON CA 94583-0995 =~ PRIMARY IV. EMERGENCY CONTACTS SECONDARY iNAME 123 NAME 128 : HARRY DYCK EMERGENCY CONTROL CENTER [TITLE 124 tITLE 129 Site Manager 24 HR EMERGENCY SERVICE BUSINESS PHONE 125 BUSINESS PHONE 130 559-454-3003 877-322-4722 24-HOUR PHONE 126 Z4-HOURPHONE 131 877-322-4722 877-322-4722 PAGER# 127 PAGER# ~ 132 559-263-2433 ADDITIONAL LOCALLY COLLECTED INFORMATION: Certification: Based on my inquiry of those individuals responsible for obtaining the information, I certify under penalty of law that I have personally examined and am familiar with the information submitted and believe the information is true, accurate, and complete. SIGNATLrRE OF OWNER/OPER.~_ R /Q DATE 134 NAME OF DOCUMENT PREPARER 135 ~ ~.~/c~~,t~.~-~ ~~'''~-'''''''~ ~"'- 12/15/2001 RHL DESIGN GROUP, INC. - AGENT FOR PACIFIC BELL NAME OF SIGNER (pnnt) 136 TITLE OF SIGNER 137 .. Steve Skanderson Project Manager UPCF (1/00 revised) 167 OES FORM 2730 (1/99) U,~,,.IED PROGRAM CONSOLIDATED l.~,tM HAZARDOUS MATERIALS HAZARDOUS'MATERIALS INVENTORY - C}IEMIC L DESCmPTION O.e pagc pcr'~at~ial pet budding or a'ca) t tDELETE I IRinsE 200 I 5 of,.I FAcrLrrY I FOR ATION }BUSINESS NAME Pacific Bell SA098 Ic~MIC,U. LOCAnON !C.~CAL LOCAnON CO~[~ ! NORTHWEST SIDE OF LOT EPCRA ~ YES [~ NO ?~??~, ~?~ I M~ (opfio~l) 203 G~ (opdo~l) Il. CHEMIC~ ~FO~TION 202 2O4 CHEMICAL NAME COMMON NAME PETROLEUM HYDROCARBON DIESEL FUEL #2 205 207 CAS# 209 68476-34-6 TRADE SECRET ~--~ Yes ~-~No If Subject to EPCRA, tefra' to instructions IfEHS is "Yes", all amounts below must be in lbs. 206 208 FIRE CODE HAZARD CLASSES (Complete if required by CUPA) COMBUSTIBLE LIQ, II 210 HAZARD MATERIAL 2~ 1 212 TYPE (Chcck one item ~a. PURE ~b. MIXTURE ~c. WASTE RADIOACTIVE ~Yes ~No CURIES tPHYSICAL STATE 214 I(Check one item only) ~] a. SOLID ~] b. LIQUID [~] C. GAS LARGEST CONTAINER 5000 FED HAZARD CATEGORIES (AVERAGE DAILY AMOUNT 213 215 216 217 MAXIMUM DAILY AMOUNT 218 ANNUAL WASTE AMOUNT ~_ 5000 5000 !L .* [~ a. GALLONS [--] b. CUB1CFEET ~ c. POUNDS ~ d. TONS Check one item only) ifEHS, amount must be in pounds. STORAGE ~a. ABOVE GROUND TANK ~el PLASTiC/NONMETALLiC DRUM i~i FIBER DRUM CONTAINER ~b.'UNDERGROUND TANK CAN BAG ' _~c. TANK INSIDE BUlLDING. CARBOY . BOX L~d. STEEL DRUM SILO CYLINDER STATE WASTE CODE 220 · 221 DAYS ON SITE:365 OTHER m. GLASS BOTTLE n. PLASTIC BOTTLE o. TOTE BIN p. TANK WAGON 223 STOP. AGE ?RESSURE ~ a. AMbIENT ~b. ASOVE ~Sm~ ~. ~ELOW AMBIE~ ~4 STO~GETEMPE~TURE ~a. AMBm~ ~b. ~OVE~B~ ~c. BELOW~B~ ~d. CRYOGENIC ~5 %~ ~RDOUS COMPONE~ ~or mixture or w~te only) EHS . CAS~ 99.5% ~6 DIESEL FUEL NO. 2 ~7 ~es ~o ~8 6M76-~ ~ 2 0.5% 2~ NAPHTHALENE ~1 ~cs '~o 232 91-20-3 2~ 3 2~ PETROLEUM DISTIL~TES 2~ ~es - ~o 236 NONE 237 '4 2~ 239 ~cs '~o 2~ 241 lf~r~ ~do~ co~nm~ ~e ~t at ~ ~ 1% ~ weight if ~n-~ogmic, ~ 0. I% ~ w~t if~m8~c, ~h ~tb~ sh~ of~ ~g th~ ~u~ ~o~ion. ADD~IONAL LOCALLY COLLECTED ~O~ATION 246 ~EPC~, Ple~e Si~ Hem UPCF (1/99) 169 OES Form 2731 III m"~ U,,..- lED PROGRAM CONSOLIDATED ~ HAZARDOUS MATERIALS HAZARDOUS MATERIALS INVENTORY- CHEmiCAL DESCRIPTION One page per rrmerial per bufldiog or area) ]ADD i ]DELETE IXl REVISE 200 I. FACILITY INFORMATION IBUSINESS NAME ~ Pacific Bell SA098 ICHEMICAL LOCATION CI-~MICAL LOCATION CONFIDENTIAL 202 STORED IN FACILITY EPCRA [] YES [~ NO II. CHEMICAL INFORMATION FACILITY ID# 203 GRIDgE4 (optional) 204 ChEMICAL, NAME 205 TRADE SECRET ~ ~ 206 Yes No LEAD/ACID BA'VrERY W/SULFURIC ACID ~ L~ If Subject to EPCRA, refer to instmctio~ COMMON NAME 207 208 BA'VI'ERY ELECTROLYTE-WET CELL EHS ~ Yes ~-~ No CAS# 209 7664-93-9 IfEHS is "Yes", all amounts below must be in lbs. FIRE CODE HAZARD CLASSES (Complete ifr~uired by CUPA) 210 CORROSIVE HAZARD MATERIAL TYPE (Check one item L.~ a. PURE ~X~ b. MIXTURE !PHYSICAL STATE {(Check one item only) ~-] a. SOLID [~ b. LIQUID iFED HAZARD CATEGORIES i(Check all that apply) AVERAGE DAILY AMOUNT 1740 Check one item only) 211 212 213 ~ c. WASTE RADIOACTWE ~-~ Yes ~ No CURIES. ["-~ c. GAS 214 LARGEST CONTAINER 8.3 215 216 ~-~ c.?RESSURE RELEASE r-~ d. ACUTE HEALTH ~ e. CHRONIC HEALTH 219 STATE WASTE CODE 221 DAYS ON SITE: 365 STORAGE ~P~-~°I RAIL CAR CONTAINER OTHER ~-~a. FIRE ~-~ b. REACTIVE 2~7 MAXIMUM DAILY~740AMOUNT 2~8 ANNUAL WASTE AMOUNT 220 ~ a. GALLONS ~ b. CUBIC FEET ~ c. POUNDS ~ d. TONS 222 if EHS. amount must be in pounds. ~i ABOVE GROUND TANK ~eI PLASTIC/NONMETALLICDRUM i~(. FIBERDRUM ~m. GLASS BOTTLE UNDERGROUND TANK CAN BAG ~_~n. PLASTIC BOTTLE TANK INSIDE BUILDING CARBOY BOX ~__~o..TOTE BIN STEEL DRUM SILO CYLINDER [~p. TANK WAGON 223 STORAGE PRESSURE' ~-~ a. AMBIENT ~--~b. ABOVE AMBIENT [-~c. BELOW AMBIENT 224 %WT HAZARDOUS COMPONENT (For mixture or waste only) EHS CAS# ~ 8-37 226 SULFURIC ACID 227 ~Yes [~No 22~ 7664-93-9 220 12 ~2-~5 230 WATER 23~ [~Yes ~No 232 7732-~8-5 233 i3 67-77 234 LEAD 235 [~es ~No 2:36 7439-92-~ 237 i 239 [~'es [~No 240 7440-50-8 241 !4 <1 238 COPPER 15 .2-.3 242 CADMIUM 243 ~--]Yes [~[No 244 7440-93-9 245 Ir'more hazardous compoaem~ are present at gr~at~- than I% by weight if no,-carcinosmi¢, or 0.1% by w6ght if carcinog~.i¢, ah additional sheens of paler capturing th~ r~quir~d infom~ation. ADDITIONAL LOCALLY COLLECTED INFORMATION 246 If EPCRA, Please Sign Here UPCF (1/99) 169 OES Form 2731 PACIFIC~ BELL ]UAP# 1 BUSINESS NAME PACIFIC BELL BKFDCA14 SA098 SITE MAP BUSINESS ADDRESS 3221 S. H STREET BAKERSFIELD DATE 11/07/2000 ZIP CODE 93304 PREPARED b,; DRAWING SCALE NOT TO SCALE SYMBOL LI=GI=ND 9 A oZ RESIDENTIAL COMMERCIAL AND RESIDENTIAL PACIFIC BELL BUILDING PLANZ ROAD B CANAL M ELECTRICAL PANEL SHUT-OFF NATURAL GAS SHUT-OFF WATER SHUT-OFF EMERGENCY PUMP SHUT-OFF TANK MONITORING ALARM TELEPHONE FIRST AID KIT FIRE EXTINGUISHER STORM DRAIN SANITARY SEWER STAGING .AREA EVACUATION/ HMMP, AND MSBS LOCATION FIRE HYDRANT FENCE EMERGENCY RESPONSE EQUIPMENT/ABSORBENTS ABOVEGROUND STORAGE TANK UNDERGROUND STORAGE TANK MOTOR OILS &. LUBRICANTS (COMBUSTIBLE LIQUID BATTERY ELECTROL' (CORROSIVE LIQUID GASOLINE (FLAMMABLE LIQUIDS) DIESEL FUEL (COMBUSTIBLE LIQUIDS) NITROGEN (COMPRESSED GAS) PROPANE (FLAMMABLE LIQUID) ACETYLENE (COMPRESSED GAS) ANTIFREEZE/COOLANTS WASTE OIL (FLAMMABLE LIOUID) FIRE PULL BOX PACIFIC; ~l~' BELL ]MAP# ' 2 BUSINESS NAME PACIFIC BELL BKFDCAI 4 BUSINESS ADDRESS 5221 S. H STREET iST FLoO SA098 BAKERSFIELD PLAN DA~E ~/0¥~000 ZIP CODE 95304 PREPARED'u~: ~ DRA~NG SCALE NOT TO SCALE SYMBOL LEGEND I ENGINE[ POWER 4 ROOM ROOM 5 6 STORAGE ® MAP (~) J ADMINISTRATION OFFICE STOR. FSi; ROOM MECH.z~" ELECT. MDF LUNCH iROOM z:~' R/R R/R DATA NET ROOM NORTH ELECTRICAL PANEL SHUT-OFF NATURAL GAS SHUT-OFF WATER SHUT-OFF EMERGENCY PUMP SHUT-OFF TANK MONITORING ALARM TELEPHONE ~ FIRST AID KIT FIRE EXTINGUISHER STORM BRAIN SANITARY SEWER STAGING AREA EVACUATION/ HMMP, AND MSDS LOCATION FIRE HYDRANT FENCE EMERGENCY RESPONSE EQUIPMENT/ABSORBENTS ABOVEGROUND STORAGE TANK UNDERGROUND STORAGE TANK MOTOR OILS & LUBRICANTS (COMBUSTIBLE LIQUID! BATTERY ELECTROLY (CORROSIVE LIQUID) GASOLINE (FLAMMABLE LIQUIDS) DIESEL FUEL (COMBUSTIBLE LtOUIDS) NITROGEN (COMPRESSED GAS) PROPANE (FLAMMABLE LIQUID) ACETYLENE (COMPRESSED GAS) ANTIFREEZE/COOLANTS WASTE OIL (FLAMMABLE LIQUID) FIRE PULL BOX PACIFIC ~r~ BELL [MAP// 3 BUSINESS NAME PACIFIC BELL BKFDCA14 BUSINESS ADDRESS 3221 S. H STREET 2ND FLUOR SA098 BAKERSFIELD PLAN ~A~E ~/0~/~000 ZIP CODE 93504 NORTH CO LOCATION AREA PSW MECH. ' EQUIPMENT ROOM SWITCH [ STOR. OFFICE I 9 A B K L PREPARED b~: L DRAWING SCALE NOI lO SCALE SYMBOL LEGEND ELECTRICAL PANEL SHUT-OFF NATURAL GAS SHUT-OFF WATER SHUT-OFF Q EMERGENCY PUMP SHUT-OFF TMAA TANK MONITORING ~ ALARM TELEPHONE ~ FIRST AID KIT Z~ FIRE EX1]NGUISHER ~ STORM DRAIN ~ SANITARY SEWER ~ STAGING AREA EVACUAUON/ ~ HMMP, AND MSDS LOCATION · ,~-- FIRE HYDRANT )¢ × FENCI~ ~ EMERGENCY RESPONSE EOUIPMENT/ABSORBENIS ABOVEGROUNB STORAGE TANK I~-~l UNDERGROUND ~--~ STORAGE TANK Q MOTOR OILS & LUBRICANTS (COMBUSTIBLE LIQUIDJ~I~ BATTERY ELECTROLYII~ (CORROSIVE LIQUID)- Q GASOLINE (FLAMMABLE LIQUIDS) O DIESEL FUEL (COMBUSTIBLE LIQUIDS) O NITROGEN (COMPRESSED GAS) PROPANE (FLAMMABLE LIQUID) ACETYLENE (COMPRESSED OAS) Q ANTIFREEZE/COOLANTS WASTE OIL (FLAMMABLE LIOUID) ] FIRE PULL BOX .. M PACIFIC BELL SA098 Manager : Location: 3221 S H ST City : BAKERSFIELD CommCode: BAKERSFIELD STATION 05 EPA Numb: SiteID: 015-021-000895 BusPhone: Map : 124 Grid: 07C (661) 832-8370 CommHaz : Low FacUnits:' 1 AOV: SIC Code:4813 DunnBrad:10~.340-1618 Emergency Contact / Title HARRY DYCK / FACILITY MGR Business Phone: (559) 454-3003x 24-Hour Phone : (877) 322-4722x Pager Phone : (559) 263-2433x Emergency Contact / Title EMERGENCY CONTROL / 24 HOURS Business Phone: (877) 322-4722x 24-Hour Phone : (877) 322-4722x Pager Phone : ( ) - x Hazmat Hazards: RSs Fire React ImmHlth Contact : STAN BRODECKI MailAddr: 2600 CAMINO RAMON 3E000T City : SAN RAMON Phone: (925) 823-6161x State: CA Zip : 94583-0995 Owner PACIFIC BEL Address : 2600 CAMINO RAMON 3E000T City : ~SAN RAMON Phone: (877) 823-9833x State: CA Zip : 94583-0995 Period : to TotalASTs: = Gal Preparer: TotalUSTs: = Gal Certif'd: RSs: Yes Emergency Directives: (TYp~ o~ print name) reviewed ths attached hazardous m~erials manage- mere plan for '~.~'/~ C/~ and ~hm i~ alon~ wi~h (Na~ of ~Sine~) any corre~ions constitute a complete and ~ man~ agement plan for my facili~. -1- 05/07/2002 PACIFIC BELL SA098 SiteID: 015-021-000895 STORAGE CONTAINER DATA (UST FORM A) Last Action Type: FACILITY/SITE INFORMATION Business Name: PACIFIC BELL SA09~8 Cross Street : Business Type: Org Type: .Total Tanks : 1 IndnRes/Trust: No PA Contact: PROPERTY OWNER INFORMATION Phone: State: Zi~: TANK oWNER INFORMATION Phone: State: Zip: Name : EMERGENCY CONTROL Address: City : Type : Name : EMERGENCY CONTROL Address: City : Type : (877) 322-4722x (877) 322-4722x BOE UST Fee# : 31914 Financ'l Resp: SELF INSURED Legal Notif : Tank Owner Mailing Address Date:06/07/2000 Phone: (800) 757-6575x Name:ARMI STRICKLAND Ttl:ENVIRONMENTAL ASSOCIATE State UST # : 1998 Upg Cert#: 00790 ~ Hazmat Inventory --Alphabetical Order Hazmat Common Name... DIESEL FUEL SULFURIC ACID (BATTERIES) ISpecHazI One Unified List Ail Materials at Site EPA HazardsI Frm DailyMax }UnitlMcP F IH L 5000.00 GAL Low F R IH L 1740.00 GAL Hi -2- 05/07/2002 PACIFIC BELL SA098 SiteID: 015-021-000895 ---- inventory Item 0001 Facility Unit: Fixed Conta~iners on Site DIESEL FUEL Days On Site 365 Location within this Facility Unit Map: Grid: UNDERGROUND TANK NW SIDE OF LOT CAS# 68476-34-6 STATE --u-TYPE PRESSURE Ambient Pure Liquid TEMPERATURE Ambient CONTAINER TYPE UNDER GROUND TANK Largest Container 5000.00 GAL AMOUNTS AT THIS LOCATION Daily Maximum 5000.00 GAL Daily Average 5000.00 GAL %Wt. 100.00 HAZARDOUS COMPONENTS Diesel Fuel No. 2 RN~oRS CAS# 68476302 TSecret No HAZARD ASSESSMENTS RS BioHazI Radioactive/Amount EPA Hazards No NoI No/ Curies F IH I N FPA I USDOT~ I1'1 MCP Low Inventory Item 0002 Facility Unit: Fixed Containers on Site ~~ ~Vl~ / ~l ~ ~vl~ SULFURIC ACID (BATTERIES) Days On Site 365 Lo'cation within this Facility Unit Map: Grid: STORED IN FACILITY CAS# 7664-93-9 FLSTATE TYPE PRESSURE iquid I Mixture Ambient TEMPERATURE Ambient CONTAINER TYPE PLASTIC CONTAINER Largest Container 8.30 GAL AMOUNTS AT THIS LOCATION Daily Maximum 1740.00 GAL Daily Average 1740.00 GAL %Wt. 30.00 HAZARDOUS COMPONENTS Sulfuric Acid(EPA) N 7664939 TSecret No RSiBioHaz Yes No HAZARD ASSESSMENTS Radioactive/Amount EPA Hazards No/ Curies F R IH NFPA 111 I USDOT# I MCP Hi -3- 05~07/2002 PACIFIC BELL SA098 SiteID: 015-021-000895 Fast Format = Notif./Evacuation/Medical --Agency Notification CALL 911. Overall Site o5/ol/2OOO -- Employee Notif./Evacuation 02/22/1994 BUILDING WARDEN DIRECTS PROCEDURES FOR NOTIFICATION AND EVACUATION IN CASE OF AN EMERGENCY. SHOUTING, HORNS, ALARMS, VOCAL, WHISTLE AND FIRE ALAMRS ARE USED TO NOTIFY EMPLOYEES TOEVACUATE. THE INSTURCT'IONS FOR EMERGENCY EXITS AND ALTERNATE ROUTES TO BE USED FOR EVACUATION ARE POSTED ON EACH FLOOR. -- Public Notif./Evacuation 02/22/1994 PACIFIC BELLS EMERGENCY OPERATING PROCEDURES SI 131, SECTION 5 IDENTIFIES THE BUILDING WARDEN/SITE MANAGER AS THE RESPONSIBLE EMPLOYEE TO NOTIFY THE BUILDING OCCUPANTS AND THE APPROPRIATE EMERGENCY CONTACTS: LOCAL FIRE/MEDICAL PERSONNEL LOCAL ADMINISTERING AGENCY OFFICE OF EMERGENCY SERVICES PACIFIC BELL EMERGENCY CONTROL CENTER SECURITY MEDICAL FACILITY ENVIRONMENTAL MANAGEMENT SAFETY Emergency Medical Plan 05/12/1998 EMPLOYEE'S OWN DOCTOR OR 911. THE IMMEDIATE SUPERVISOR OR AVAILABLE BUILDING WARDEN IS RESPONSIBLE FOR CONTACTING AN AMBULANCE OR MEDICAL FACILITY FOR AN INJURED EMPLOYEE. NEAREST EMERGENCY MEDICAL FACILITY - SAN JOAQUIN COMMUNICTY HOSPITAL - 2615 EYE ST - 395-3000. -4- 05/07/2002 PACIFIC BELL SA09~ SiteID: 015-021-000895 Fast Format ~ Mitigation/Prevent/Abatemt --Release Prevention PERIODIC TESTS MADE ON UNDERGROUND TANK. Overall Site o /o9/1996 MATERIALS: HAZARDOUS MATERIALS ARE UTILIZED AND STORED FOLLOWING MANUFACTURER RECOMMENDATIONS AS WE ARE A CONSUMER OF PRODUCTS AND NOT A MANUFACTURER OF HAZARDOUS MATERIALS. TRAINING: EMPLOYEES ARE PROVIDED TRAINING ANNUALLY THROUGH THE PACIFIC SAFETY PLAN MODULES ON HOW TO HANDLE HAZARDOUS MATERIALS AND HOW TO READ M.S.D.S. AS REQUIRED BY THE HAZARDOUS COMMUNICATION STANDARD. ADDITIONALLY', ANNUALLY THEY ARE TRAINED ON EMERGENCY OPERATING PROCEDURES (SI 131-5) AND PACIFIC SAFETY PLAN. --Release Containment 05/01/2000 ELECTROLYTE IS CONTAINED IN BATTERIES AND BATTERIES ARE SECURED IN A SPECIALLY DESIGNED BATTERY RACK WHICH WORK IN CONJUNCTION WITH EARTHQUAKE BRACING. DIESEL FUEL: CONTAINED IN AN UNDERGROUND, DOUBLE WALL STEEL TANK MONITORED -- Clean Up 04/09/1996 THE PACIFIC BELL HAZARDOUS MATERIALS WASTE/MANAGEMENT HANDBOOK, AND THE HAZARDOUS MATERIALS BUSINESS PLAN USER GUIDE REQUIRED THAT A HAZARDOUS INCIDENT REPORT FORM (FR-0023) BE COMPLETED IN THE EVENT OF A SPILL OR A RELEASE OF A HAZARDOUS MATERIAL AT PACIFIC BELL FACILITIES. CONTRACTORS UTILIZED TO CLEAN UP SPILLS AND RELEASES INCLUDE: IT CORP. RIEDEL ..... 415-372-9100 415-234-7400 Other Resource Activation AS OUTLINED IN PACIFIC BELL'S HAZARDOUS MATERIALS MANAGEMENT PLAN ITEM G "UNAUTHORIZED RELEASE~ (LEAKS AND SPILLS) OF PETROLEUM PRODUCT WILL BE REPORTED IMMEDIATELY BY THE OPERATOR OF THE UNDERGROUND TANK TO THE FOLLOWING: PACIFIC BELL EMERGENCY CONTROL CENTER PACIFIC BELL REAL ESTATE STAFF (916) 977-7777 (510) 823-1028 ANY UNAUTHORIZED RELEASES WILL BE RECORDED USING THE HAZARDOUS MATERIAL INCIDENT REPORT FORM NUMBER FR-0023, AS SHOWN IN APPENDIX III. FOR INCIDENTS INVOLVING SPILL, THE OPEP~ATOR OF THE UNDERGROUND TANK WILL NOTIFY -5- 05/07/2002 PACIFIC BELL SA098 SiteID: 015-021-000895 Fast Format Site E~ergency Factors Special Hazards Overall Site -- Utility S~ut-Offs 05/12/1998 A) GAS - NONE B) ELECTRICAL - N SIDE OF BLDG IN POWER ROOM C) WATER - E SIDE OF LOT IN SIDEWALK D) SPECIAL - TANK MONITOR ALARM - ENGINE ROOM; SPILL KIT/ABSORBENT - BATTERY AREA; FIRST AID KIT - POWER/ENGINE AREA E) LOCK BOX·- NO Fire Protec./Avail. Water 05/01/2000 PRIVATE FIRE PROTECTION - BLDG iS ALARMED AND MONITORED 24 HOURS A DAY FIRE EXTINGUISHERS ARE LOCATED THROUGHOUT THE BLDG. NEAREST FIRE HYDRANT - FIRE STATION IS 1 BLOCK E OF THE FACILITY. Building Occupancy Level -6- 05/07/2002 PACIFIC BELL SA098 SiteID: 015-021-000895 Fast Format Training -- Employee Training Overall Site 03/24/1993 WE HAVE 15 EMPLOYEES AT THIS FACILITY. WE HAVE MATERIAL SAFETY DATA SHEET AVAILABLE. BRIEF SUMMARY OF TRA'INING PROGRAM: EMPLOYEES ARE PROVIDED INITIAL SAFETY PLAN TRAINING ON THE HAZARD RECOGNITION/COMMUNICATION MODULE AS WELL AS THE FUNCTION SPECIFIC MODULES BEFORE THEY BEGIN THEIR WORK OPERATIONS. THIS ALSO INCLUDES TRAINING ON THE EMERGENCY OPERATING PROCEDURES (SI 131, SECTION 5). THE PACIFIC SAFETY PLAN AND THE EMERGENCY OPERATING PROCEDURES REQUIRE ANNUAL REFRESHER TRAINING, BE PROVIDED. Page 2 Held for Future Use Held for Future Use -7- 05/07/2002 D June 30, 2002 Pacific Bell 3221 So. "H" Street Bakersfield, CA 93304 REMINDER NOTICE FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 326-0576 ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 326-0576 TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 RE: Necessary Secondary Containment Testing Requirement by December 31, 2002 of Underground Storage Tank located at 3221 So. "H" Street. Dear Tank Owner / Operator: The purpose of this letter is to inform you about the new provisions in California Law requiring periodic testing of the secondary containment of underground storage tank systems. Senate Bill 989 became effective January 1, 2002, section 25284.1 (California Health & Safety Code) of the new law mandates testing of secondary containment components upon installation and periodically thereafter, to ensure that the systems are capable of containing releases from the primary containment until they are detected and removed. Secondary containment systems installed on or after January 1, 2001 will be tested upon installation, six months after installation, and every 36 months thereafter. Secondary containment systems installed prior to January 1, 2001 will be tested by January 1, 2003 and every 36 months thereafter. REMEMBER! Any component that is "double-wall" in your tank system must be tested. Secondary containment testing shall require a permit issued thru this office and shall be performed by either a licensed tank tester or licensed tank installer. Please be advised that there are only a few contractors who specialize and have the proper certifications to perform this necessary testing. For your convenience, I am enclosing a copy of the code for you to refer to. Once again, all testing must be done under a permit issued by this office. Should you have any questions, please feel free to contact me at (661)326-3190. Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Environmental Services SU/kr EXHIBIT A 2002 UST FINANCIAL RESPONSIBILITY KERN COUNTY Agency Location / City / Site Contact Bakersfield Fire Dept ~ 3221 So. "H" Street ~ Bakersfield -- - lHarry Dyck Bakersfield Fire Dept ! 1918 "M" Street f Bakersfield Harry Dyck Bakersfield Fire Dept 5650 Aldrin Ct / Bakersfield Cindy Madrigal Bakersfield Fire Dept 3501 Columbus Ave Bakersfield Harry Dyck Kern County Health Dept 925 Jefferson St Delano Harry Dyck Kern County Health Dept 8313 E Segrue Road Lamont Harry Dyck Kern County Health Dept 1021 California St Oildale Harry Dyck Bakersfield Fire Dept 11609 Rosedale Hw7 I Rosedale Harry D¥ck State o£ W~:cr ~:sourc:s Control Board ~z~~ ~~~~ ~ Division of Cle~ Water Progr~s ~~i~~ ~ ~'~:~ '~' '~ ~ .... P.O. Box 944212 ~,:~.S>~~ ~~'~~;~ Sacramento, CA 94244-2120 (lm~ctions on reverie side) ~~ ~ D . ~Y~ CERTIFICATION OF FINANGIAL RESPONSIBILITY FOR U~gRGROUND STOOGE T~KS CONTAIN~G P~TROL~ A. [ ~ requi~ to 8emonst~te Fin~cial Responsibili~ in ~e Require~ mount ~ specifie~ in Section 280~, CB~pter 18, Div. 3, Titl~ 23, CCR: ~ >00,000 ~ollnrs pe~ occu=enc= ~ I million ~oll= =null aggregute or ~D or ', ~ I million ~oll=s per oceu==nee ~ 2 million ~oll=s ~nual ag~egate 8. Pacific Bell hereby ce~fie~ that it i~ in compliance wi& ~e requirements of Section 2807, (Name of Tank Owner or Ope~tod A~icle 3, Chapter 18, Division 3, Utle 23, Califomia Code of RegulaEons. The mechani~m$ used to demon~t~te financial ~spon~ibili~ a$ requi~d by Section 2807 are as follow$: BBC Not Ap¢icable $2,000,000 Per Financial Test of Self Environmental Management For State O~urrence & Annual 'Yes. Yes Insurance Paci~c Region Alternative $2,ooe,oeo May 1 - PO Box 5095, Room 3E000 Mechanism Annual April 30 · San Ramon, CA 94583-0995 Aaflreflate Note: If you are using the State Fund as any pa~ of your demonstra~on of financial ~sponsibili~. yobr execution and submission of thi~ ce~ification also cedifies that you are in compliance with all conditions for pa~icipation in the Fund. O. Facility Name F~cilityAddress SBC/Pacific Bell See Exhibit "A" Facili~ Name Facility Address Facili~ Name, FaciliW Address E. Signature o¢ Tank Owner er Operator Date Name and Title of Tank ~ner er Operator ~~~.~~~~..04126102 Start Brodecki, Senior Environmental Manager Y Signatdre of Witness or Nota~ _ Date Name of Wi~ess or Notaw 0~t2~/02 Armi ~. St~ckland CFR (~ cvi.scd 04/95) FILE: Origi.al - Local Agency Copies - Facility/Site(s) Environmental Managemenl Pacific Region PACn~IC BELL TELEPHONE COMPANY : 2002, FINANCIAL TEST OF SELF INSURANCE P.O. Box 5095 Room 5EOO0 San Ramon, California 94585 Phone 925-825-9855 Fax 925-867-0241 Pursunnt to'40 CFR 280.107(bX6), l, R~nd~ll Stephenson, Senior Executive Vice President end CFO of SBC Communications Inc. hereby certi~ for and on behnlf of PnciflC Bell TelePhone Compeny~ that It is in cOmpliance with the. requirements of Subpnrt H of 40 CFR Part 280. Pecific Bell Telephone Compnny is a subsidim-y of SBC Communications Inc. The finnncial assurance mecl/enism reed to demonstrate financial responsibility under Subpnrt H of 40 CFR 280 is'as follows: .... · ' Type of Mechanism: :, Financial Test Of Self-l. nsurence Nnme of [s~Ue~. Nevada M~cha~ism Numbe~. 40 CFR 280.95' Effe~ive P~riod of Coverage: 01/01/2002 to'12/3 !/2002 This mechenism co,(ers both "taking ~orrective action" ~nd/or "compensating ~ patties for bodilyinjm-y.end property dan~ge mused by" either "sudan ncciden~ releases" or.."nens~den ~ental telenses" or "nc¢idental releases". Name: Rnnd~ll Stephenson · · Title: SeniorExecUtive' Vice President end CFO Title: ExecutiVe Assistant to. ~enior Executive'VP nnd CFO Date of Att~tation: '~/- ~.'O ,2002 Pnge 1. of 3 PACIFIC BELL TELEPHONE COMPANY 2002 FINANCIAL TEST OF SELF INSURANCE April 3, 2002 Re: 40 CFR 280,9~ 'I am the Senior Executivc Vice President and CFO of SBC Communications lac. at 175 E. Houston, Room '1307, San Antonio, Texas. This letter is in support of the use of"the financial test of self. iusurance" to demonstrate financial responsibility for "taking corrective action" ~ "compensating third parties for bodily injury and property.damage" caused by"sudden accidental releases" and "non.5~dden accidental releases" in the amount of at least Two Million Dollars (~2,000,000.00) per occurrence and Two Million Do!l~'s ($2,000,000.00) annual aggregate arising from oper~ng certain under/round storage tank(s). Underground storage tanks at the facilities described in Exhibit I are assured by this financial test or a financial test under an authorized state program by Pacific Bell Telephone Company. Please note that all tanks are assured by this financial test or a financial test under a state program approved under 40 CFR part 281.' A "financial test" is also used by Pacific Bell Telephone Company to demonstrate evidence of financial responsibility in the following amounts undO- other EP~t regulations or state programs authorized by the EPA under 40 CFR Parts 271 and 145: EPA Regulations Amgpn; Closure (264.143 and 265.143) Post-Closure Care (264.145 and 265.145) Liability Coverage (264.147 and 265.147) Corrective Action (264.101 Co)) Plugging and Abandonment (144.63) Closure Post-Closure Care Liability Coverage Con'ecfive Action Plugging and Abandonment $ N/A $ N/A $ N/A $ N/A $ N/A $ N/A $ N/A $ N/A $ N/A $ N/A Total $ N/A SBC Communications Inc. has not received an adverse opinion, a disclaimer of opinion, or a "going concern" qualification from an independent auditor on its financial statements for the latest completed fiscal year. (Fill in the information for Alternative .I if the criteria ofp .aragraph CO) of 280.95 are being used to demonstrate. compliance with financial test requirements. Fill in the informAtion for Alternative H iftbe criteria of paragraph . (c) of 280.95 am being used to demonstrate compliance with financial test requirements). Alternative I Amount of annual UST aggregate coverage being assured by a financial test, and/or guarantee Amount of corrective action, closure and post-closure care costs, · liability coverage, plugging and abandonment costs covered by a f'mencial test, and/or guarantee ~,ooo',ooo $0' 3. Sum of lines I and 2 $2,000,000 Page 2 of 3 PACIFIC BELL TELEPHONE COMPANY 2002 FINANCIAL TEST OF SELF INSURANCE 7. 8. 9. i0, Total tangible assets Total liabilities (if any of the amount reported on line 3 is included in total liabilities, you may need to deduct that amount from this line and add that amount to line 6)* Tang~"ole net worth (line 4 minus lineS) Is line 6 at le~t $I0 million? Is linc 6 at least 10 times line 3? Have financial statements for the latest fiscal year been filed with The Securities and Exchange Commission? Have financial statements for the latest fiscal year been filed with The Energy Information AdminisU-ation? 11. Have Financial statements for the latest fiscal year been filed with · The Rural Electrician Administration? 12. Has financial information been prOvided to Dun and Bradstreat and has Dun and B~ pwvided a financial strength rating of a 4A or SA? (answer "yes" only ifboth criteria have been met) *SBC Communications Inc. Annual Report 2001 $96.322 billion $63.831 billion $32.491 billion Yes Yes Yes N/A N/A Yes · I hereby ceftin, that the wording ofthis letter is identical to the wording specified in 40 CFR Part 280.9S (d) ns such r~gulations were constituted on the dnte shown immediately below. Randall Stephenson Senior Executive Vice President and CFO (Date) Page 3 of 3 Management West Region .BC Services, Inc. O. Box 5095 oom 3E000 San Ramon, California 94583 Phone 925-823-9833 Fax 925-975-0584 Fax 925-867-0241 May 9, 2002 City of Bak~sfield - CUPA Attn: R~d~h E. Huey DirecJ~ of the Office of Environmental Services Fir,g/Department 17ti 5 Chester Avenue, Third Floor Bakersfield, CA 93301 RE: Certification of Financial Responsibility - Underground Storage Tanks Please find the enclosed copy of the annual State of California Water Resources Control Board's Certification of Financial Responsibility form to demonstrate financial responsibility for SBC/Pacific Bell and its affiliate's underground storage tanks. Also enclosed is a list, Exhibit A, of SBC/Pacific Bell sites that have underground storage tanks on the premises in your area of jurisdiction. I can be reached at (925) 823-6161 if you have questions regarding this correspondence. Senior Environmental Manager SBC Environmental Management Attachment: Certification of Financial Responsibility Exhibit "A" FIIIE D May 29, 2002 Pacific Bell 3221 So. "H" Street Bakersfield, CA,93304 FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES 2101 ~H" Street Bakersfielcl, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 SUPPRESSION SERVICES 2101 ~H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 326-0576 ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 326-0576 TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 FAX {661) 399-5763 RE: Necessary Secondary Containment Testing Requirement by December 31, 2002 of Underground Storage Tank located at 3221 So. "H" Street REMINDER NOTICE Dear Tank Owner/Operator: The purpose of this letter is to inform you about the new provisions in California Law requiring periodic testing of the secondary containment of underground storage tank systems. Senate Bill 989 became effective January 1, 2002. section 25284.1 (California Health & Safety Code) of the new law mandates testing of secondary containment components upon installation and periodically thereafter, to ensure that the systems are capable of containing releases from the primary containment until they are detected and removed. Secondary containment systems installed on or after January 1, 2001 shall be tested upon installation, six months after installation, and every 36 months thereafter. Secondary containment systems installed prior to January 1, 2001 shall be tested by January 1, 2003 and every 36 months thereafter. REMEMBER!! Any component that is "double-wall" in your tank system must be tested. Secondary containment testing shall require a permit issued thru this office, and shall be performed by either a licensed tank tester or licensed tank installer. Please be advised that there are only a few contractors who specialize and have the proper certifications to perform this necessary testing. For your convenience, I am enclosing a copy of the code for you to refer to. Once again, all testing must be done under a permit issued by this office. Should you have any questions, please feel free to contact me at (661) 326-3190. Steve Underwood Fire Inspector/Environmental Code Enforcement Officer SBU/kr enclosures MONI G SYSTEM CERTIFii . TION For Use By All Jurisdictions Within the State of Califo~ia Aut ority Cited: Chapter 6. 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name: PACIFIC BELL GEO PAR # SA-098 CLLC Code: BKFDCA14 Site Address: 3221 SO. "H" STREET City: BAKERSFIELD ziP: Facility Contact Person: RAY COX Contact Phone No.: (559) 452-4550 Make/Model of Monitoring System: B. Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment ins Tank ID: 333 15ZlIn-Tank Gauging Probe: []Annular Space or Vault Sensor: [Piping Sump/Trench Sensor (s): F1Fill Sump Sensor (s): I-IMechanical Line Leak Detector. I"lElectronic Line Leak Detector [Tank Overfill/High-level Sensor: VEEDER-ROOT TLS-350 Model: 847390-107. Model: 794390420 Model: 794380-352 Model: Model: Model: Model: 790091-001 F1Other, Specify equip, type and model in Section E on Pal~e 2 Tank ID: Flirt-Tank Gauging Probe: Model: []Annular Space or Vault Sensor: Model: UIPiping Sump/T~:ench Sensor (s): Model: I-IFill Sump Sensor (s): Model: []Mechanical Line Leak Detector. Model: F1Electronic Line Leak Detector Model: UITank Overfill/High-level Sensor: Model: F1Other, Specify equip, type and model in Section E on Page 2 Dispenser ID: I-lin-Tank Gauging Probe: Model: [] Shear Valve(s). [-IDispenser Containment Float(s) and Chain(s) Dispenser ID: []in-Tank Gauging Probe: Model: [] Shear Valve(s). []Dispenser Containment Float(s) and Chain(s) Dispenser ID: []In-Tank Gauging Probe: Model: [] Shear Valve(s). .[]Dispenser Containment Float(s) and Chain(s) Date of Testing/Service: 4/9/02 ~ected/serviced: Tank ID: Flirt-Tank Gauging Probe: Model: F1Annular Space or Vault Sensor Model: []Piping Sump/Trench Sensor (s): Model: F1Fill Sump Sensor (s): Model: FIMechanieal Line Leak Detectoi,. Model: [3Electronic Line Leak Detector Model: FITank Overfill/High-level Sensor: Model: F1Other, Specify equip, type and model in Section E on Pa~e 2 Tank ID: []In-Tank Gauging Probe: Model: []Annular Space or Vault Sensor Model: FIPiping Sump/Trench Sensor (s): Model: U1Fill Sump Sensor (s): Model: []Mechanical Line Leak Detector. Model: I-1Electronic Line Leak Detector Model: FlTank OverfillFl-Iigh-level Sensor: Model: FIOther, Specify equip, type and model in Section E on Page 2 Dispenser ID: FIDispenser Containment Sensor(s): Model: [] Shear Valve(s). ' F1Dispenser Containment Float(s) and Chain(s) Dispenser ID: []Dispenser Containment Sensor(s): Model: [] Shear Valve(s). · FIDispenser Containment Float(s) and Chain(s) · Dispenser ID: FIDispenser Containment Sensor(s):. Model: [] Shear Valve(s). []Dispenser Containment Float(s) and Chain(s) *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such repons, I have also attached a copy of the report; (check aIlthat apply): FI System set-up ! D Ah~lon b~story report Technician Name (Print): DON S. THOMPSON signature: Certification No.: 92-3354 License No.: 58~'iJ~ Testing Company Name: TAIT ENVIRONMENTAL SYSTEMS Phone No.: (714) 560-8222 Page 1 of 3 03/01 Monitoring System Certification Site Address: 3221 SO. "Fl" STREET, BAKERSFIELD Date of Testing/Servicing: 4~9~02 D. Results of Testing/Servicing Software Version Installed: 120.00 Complete the following checklist: [] Yes [] No* Is the audible alarm operational? []. Yes [] No* Is the visual alarm operational? [] Yes [] No* Were all sensors visually inspected, functionally tested, and confirmed operational? [] Yes [] No*. Were all sensors installed at lowest point of secondary containment and positioned so that 'other equipment will not interfere with their proper operation?. [] Yes [] No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) [] N/A operational? [] Yes [] No* For pressurized piping'systems, do~s the t~bine auto~aticaily shut down if the piping secondary containment [] N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) [] Sump/Trench Sensors; [] Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection?. [] Yes; [] No. []' Yes [] 'No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no [] N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and. operating properly?. If so, at what percent of tank capacity does the alarm trigger? ??.9?°./6 [] Yes* [] No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts, in Section E, below. [] Yes* [] No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) [] Product; [] Water. If yes, describe causes in Section E, below. [] Yes .[] No*' Was monitorin~ system, set-up reviewed to ensure proper settings? [] Yes [] No* Is all monitorin~ equipment operational, per manufacturer's specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: Site Address: 3221 SO. "IF' STREET, BAKERSFIELD Date of Testing/Servicing: 4/9/02 F. In-Tank Gauging / SIR Equipment: I~ Check this box if tank gauging is used only for inventory control. [] Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: [] V;s' [] No* Ha-s all input wiring been i"spected for proi>er'mtry a~d termination, including testing rod gr°Und faults.6 [] Yes [] No* Were all tank gauging probes visually inspected for damage and residue buildup? [] Y~s [] No* Was accur'acy of system product level readings tested? [] Yes [] No* Was accuracy of system water level readings tested? [] Yes [] No* Were all probes reinstalled properly.9 [] Yes [] No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): [] Check this box ifLLDs are not installed. Complete the following checklist: ' [] Yes []"' NO* V& equipment. start-~p 'or annual equipment certification, was a lea~ simfiiated t'o verify LLb performance? Fl N/A (Check all that apply) Simulated leak rate: [] 3 g.p.h.~; [] 0.1 g.p.h.2; [] 0.2 g.p.h.2 Notes: 1. Required for equipment start-up certification and annual certification. 2. Unless mandated by local agency, certification required only for electroni~ LLD start-up. [] Yes [] No* Were all LLDs confirmed operational and accurate within regulatory requirements? [] Yes [] No* Was the testing apparatus properly calibrated? [] Yes [] No* For mechanical LLDs, does the LLD restrict product flow if it dete~ts a leak? [] N/A · U3 Yes [] 'N~*' For electronic LLDs, does the turbine automatically shut off if the LLD detects ~ leak? '" [] Yes [] No* For electronic LLDs, does the turbine autom'aticall3) shut 'off if anY poRi°n of the mOnitoring system is disabied [] N/A or disconnected? [] Yes [] No* For elec~'°nic LLDs, does the turbine aat°matically shut o'ff if 'any portion of the'monitoring system [] N/A malfunctions or fails a test? [] Yes [] No* For electronic LLDs, have all accessible wiring connections been visually inspected? [] N/A [] Yes [] N°* Were all items on the equipment manufaCtUrer's maintenance checklist comPleted? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: Page 3 of 3 0S/Ol Site Address: 3221 SO. "I-1" STREET, BAKERSFIELD Date of Testing/Servicing: Monitoring System Certification UST Monitoring Site Plan Date map was drawn: Instructions If you already have a diagram that shows all required information, you may include it, rather than this page, with your Monitoring System Certification. On your site plan, show the general layout of tanks and piping. Clearly identify locations of the following equipment, if installed: monitoring system control panels; sensors monitoring tank annular spaces, sumps, dispenser pans, spill containers, or other secondary containment areas; mechanical or electronic line leak detectors; and in- tank liquid level probes (if used for leak detection). In the space provided, note the date this Site Plan was prepared. Page __ of__ os/00 FILE THIS DOCUMENT 1N THE HAZARDOUS MATERIALS PLANS PROGRAMS PERMITS BINDER SECTION 3 Pacific Underground Storage Tank(s) Routine Monitoring Procedures And Response Plan 2001 3221 S. H STREET / (Facility County) POST THIS DOCUMENT ON SITE SO THAT IT WILL BE AVAILABLE IN THE EVENT OF A GOVERNMENT AGENCY INSPECTION, SITE ASSESSMENT OR AUDIT. I:\HAZMAT\PACBELL\FORMS\SBC Monitor Plan2 Merge.doc Printed: June 13, 2001 page 1 Pacific Bell: 2600 Camino Ramon, Room 3E000, San Ramon, CA 94583 ROUTINE MONITORING PROCEDURES Section 2632 (d)(1) Title 23 CCR, Chapter 16 UNDERGROUND FUEL STORAGE TANK Facility Name: Pacific Bell (SA098) Facility Address: 3221 S. H STREET, BAKERSFIELD Ae Be UST Installed: Double Wall Composite 5,000 Gallons Containing Diesel Fuel for the Emergency Generator. Piping Installed: Double Wall piping with black iron primary and fiberglass secondary for the product supply and return lines. The Frequency of Performing the Monitoring: Monitoring is performed continuously on the: · Double wall UST Interstitial space and the piping sump. The methods and equipment used to perform continuous monitoring are: · VEEDER ROOT UST Monitoring System Model # TLS-350 · Site fax modem · GPH magnetostrictive in-tank volumetric probe Model # 847390-107 · Floating liquid sensors in the: 1. UST Annular space sensor Model # 794390-420 2. Piping sump sensor Model # 794380-352 3. Tank Overfill Model # 790091-001 I:\HAZMAT\PACBELL~FORMS\SBC Monitor Plan2 Merge.doc Printed: June 13, 2001 page 2 Locations where monitoring is performed: (see the plot plan for physical location) Continuous monitoring and leak detection are performed: In the interstitial space of the double wall UST · In the primary tank (by volumetric test) · In the piping sump 1. The Site Manager, HARRY DYCK at 559-454-3003 is responsible for performing: · Operational monitoring On site record keeping, Note: Onsite records are maintained on a board mounted in the facility. And label "Facility Information Center" and contains the UST Routine Monitoring & Response Plan, Hazardous Material Business Plan and other environmental records and permits. · The reporting of any discrepancies and alarms with the monitoring system, UST, piping, and associated hardware. 2. SBC - Environmental Management (California & Nevada region) at (800) 757- 6575 is responsible for all maintenance and repairs to the UST monitoring system, UST, piping, and all associated hardware. Reporting format: A site fax modem with auto-dial for up to 8 phone numbers is installed to fax all alarms and warnings 24 hours a day to SBC - Environmental Management and to an alarm monitoring/maintenance company on TLS-350s. SBC - Environmental Management uses computers with Internal Environmental Management software program for accessing/polling all facilities with Veeder Root TLS-350's on a daily basis; of all inventory, alarms, warnings, in tank leak detection, and sensors leak detection status, performing set up and programming changes, and system diagnostics with all data being stored. I:\HAZMAT\PACBELL\FORMS\SBC Monitor Plan2 Merge.doc Printed: June 13, 2001 page 3 Preventative maintenance, calibration, certification to manufacturer's specificati°n and repair for the UST monitoring system and associated hardware are performed on a minimum annually. SBC - Environmental Management directs, manages, and schedules all maintenance and repairs for the California and Nevada region's, UST's, piping, associated hardware, and UST monitoring systems preventative maintenance, calibration, certification and repairs. Currently SBC - Environmental Management (California & Nevada region) has an annual contract with Tait Environmental Systems, 701 North Parkcenter Drive, Santa Ana, CA 92705, Phone (714) 560-8643 or fax (714) 560-8200 to perform Calibration and field services. G. Training: SBC Hazardous Materials/Wastes Management Handbook, Section 20 Titled "Underground and Aboveground Storage Tanks" describes the methods and procedures company employees follow for underground and Aboveground storage tank and monitoring systems. UST and the Veeder Root TLS-350 monitoring system operating instructions are on- site. On-site training is performed on initial start-up of the UST monitoring system and refresher training is performed on an as needed basis. I:\HAZMAT\PACI3ELL\FORMS\SBC Monitor Plan2 Merge.doc Printed: June 13, 2001 . page 4 Pacific Bell: 2600 Camino Ramon, Room 3E000, San Ramon, CA 94583 UST RESPONSE PLAN (Section 2632(d)(2) Title 23 CCR, Chapter 16) UNDERGROUND FUEL STORAGE TANK Facility Name: Pacific Bell (SA09g) Facili;y Address: 3221 S. H STREET, BAKERSFIELD Bo An unauthorized release of any hazardous substance and/or water from the interstitial space, fill sump, piping sump, and piping vault, will be removed within 30 days by hand/electrical pump for small quantities and by vacuum truck for large quantities. Small quantities of any hazardous substance will be placed into steel drums. Large quantities will be placed into a vacuum truck tank. An SBC authorized vendor will perform removal and disposal of any hazardous substance. Spill Kits containing Absorbent pads are located on site in the BATTERY AREA for immediate Reponses to any release. Name(s) and title(s) of the person(s) responsible for authorizing any work necessary under the response plan: Primary Contact: Title: Secondary Contact: Executive Contact: Title: HARRY DYCK Site/Facility Manager OICC: Emergency Control Center 24 hours/day, 7 Days/Week Environmental Management Hotline Stan Brodecki Sr. Environmental Manager Corporate Environmental Management Phone Number: 559-454-3003 Phone Number: 877-322-4722 800-757-6575 (8am- 5pm) Phone Number: 925-823-6161 I:\HAZMAT\PACBELL\FORMS\SBC Monitor Plan2 Merge.doc Printed: June 13, 2001 page 5 2 3 4 5 9 PACIFIC BELL IMA?# 1 BUSINESS NAME PACIFIC BELL BKFDCA14 SA098 SITE MAP BUSINESS ADDRESS 3221 S. H STREET BAKERSFIELD DATE 11/07/2000 7, IP CODE 95504 (Z RESIDENTIAL COMMERCIAL <~> AND ~ ~ I I RESIDENTIAL ~_J PACIFIC BELL BUILDING CANAL PLANZ ROAD DRA~NG SCALE NOT TO SCALE SYMBOL LEGEND G ELECTRICAL PANEL SHUT-OFF G NATURAL OAS SHUT-OFF Q WATER SHUT-OFF ~ EMERGENCY PUMP SHUT-OFF ?~A, TANK MONITORING ALARM Q TELEPHONE c~ FIRST AID KIT Fz~ FIRE EXTINGUISHER ~ STORM DRAIN ~ SANITARY SEWER ~ STAGING AREA EVACUATION/ r~ HMMP, AND MSDS LOCATION ~ FIRE HYDRANT )( )( FENCE EMERGENCY RESPONSE EQUIPMENT/ABSORBENTS (--) ABOVEGROUND STORAGE TANK (r--~) UNDERGROUND ~--~ STORAGE TANK Q MOTOR OILS & LUBRICANTSI (COMBUSTIBLE LIQUI~ Q BATTERY ELECTROL~ (CORROSIVE LIOUID)~ Q GASOLINE (FLAMMABLE LIQUIDS) <~ DIESEL FUEL (COMBUSTIBLE LIQUIDS) Q NITROGEN (COMPRESSED GAS) Q PROPANE (FLAMMABLE LIQUID) <~> ACETYLENE (COMPRESSED GAS) Q ANTIFREEZE/COOLANTS (~ WASTE OIL (FLAMMABLE LIQUID) ] FIRE PULL BOX A B C D E F G H I d K L M Veeder-Root California Edition: June 1999 TLS-200/200i/250/250i/300/300c/300i/300pc/350/350pc/350r/350rpc UST ATGS (8473 Digital Sensing Magnetostrictive Probe) _ · ' AUTOMATIC TANK GAUGING SYSTEM Certification: 'Leak rate of 0.2 gph with PD=99% and PF^=0.1%. Leak Threshold: 0.093 gph. A system should not be declared tight if the test result indicates a loss or gain .that equals or exceeds this threshold. Applicability: Tank Capacity: Gasoline, diesel, aviation fuel, and solvents. Maximum of 15,000 gallons. Tank must be between 50 and 95% full. Waiting Time: Test Period: Minimum of 8 hours, 18 minutes between delivery and testing. Minimum of 30 minutes between dispensing and testing. There must be no delivery dmfng waiting time. Minimum of 2 hours. Test data are acquired and recorded by the system's computer. Leak rate is calculated l~om the difference between the first and last data collected. There must be no dispensing during test. Temperature: Water Sensor: Calibration: Average for product is determined by a minimum of 5 thermistors. Must be used to detect water ingress. Minimulll detectable water level in ~e tank is 0.544 inch. Minimum detectable change in water level is 0.027 inch. Tkermistors and probe must be checked and Calibrated in accordance with manufacturer's instructions. Comments; Not evaluated using manifold tank systems. Tests only portion of tank containing product. As product level is lowered, leak rate in a leaking tank decreases (due to lower head pressure). Consistent testing at low levels could allow a leak to remain undetected. EPA leak detection regulations require testing of the portion of the tank system which routinely contains product. C~lifornia regulations require at least one test per month after routine product delivery or when the tank is £dled to within 10% of the highest operating level during the previous month. Veeder-Root 125 Powder Forest Dr. Simsbury, CT 06070-2003 Tel: (860) 651-2700 Evaluator: Midwest Research Institute Tel: (816) 753-7600 Date of Evaluation: 05/14/93 Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. 314 Veeder-Root California Edition: June 1999 TLS-250, TLS 250i Plus, ILS 250, ILS 350, TLS-300/300c/300i/300pc, TLS-350 Series Interstitial Liquid Sensor for Steel Tanks (0794390-420, -460) LIQUID-PHASE INTERSTITIAL DETECTOR Detector: Output type: Sampling frequency: Operating principle: qualitative continuous float switch Test Results: Accuracy (%) Kesponse time (rain) Recovery time (min) Product activation height (cra) Lower detection limit (em) *TLS-250, TLS 250i Plus, ILS 250 ** ILS 350, TLS-350 ' unleaded synthetic gasoline ' gasoline" 100 100 6.00 6.51 <1 <1 3.67 3.62 4.05 4.17 Specificity Results: Activated: diesel fuel, synthetic fuel, heating off #2, water. Comments: . Results shown are from July 1992 evaluation. April 1998 evaluation yielded similar results. EPA and many states require detection of 1/8 inch (0.32 em) of product for groundwater,monitoring. Test procedures used were Carnegie Mellon Kcscarch Institutc's "Test Procedures for Third Party Evaluation of Leak Detection Methods: Point Sensor Liquid Contact Leak Detection Systems": Final Report - November 11, 1991. Detector is reusable. Veeder-Root 125 Powder Forest Dr. Simsbury, CT 06070-2003 Tel: (860) 651-2700 Evaluator: Carnegie Mellon Research Institute Tel: (412) 268-3495 Dates of Evaluation: 07/17/92, 04/22/98 Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. 317 Method Name Version Vendor Results of Third Party Standard Evaluation Point Sensor Liquid Contact Product Detectors This form documents the performance of the cable sensor liquid contact leak detection system described below. The evaluation was conducted by the equipment manufacturer or a consultant to the manufacturer according to the Third Party Procedures developed according to the U.S, EPA's 'Standard Test Procedure for Evaluating Leak Detection Methods: Liquid-Phase Out-of-Tank Product Detectors,"1 Tank owners using this leak detection system should keep this form on file to prove compliance with the federal regulations. Tank owners should check with state and local agencies to verify that this form satisfies their requirements. Description - 350 Series UST.Monitodn~ Systems: Models ILS 350 fserial #Beta 013~ & TLS 350 with Interstitial Liauid Sensor for Steel Tanks (0794390-420) Veeder-Root Envimqmental Products 125 Powder Forest Driy~ (street address) Simsb~ry, - . CT (city) (state) 06070-2003 (800) 873-3313 (zip) (phone) Detector output type: X Qualitative Detector operating principle: Electrical Conductivity Capacitance Change , Interlace Probe Product Permeable Product Soluble Thermal Conductivity Pressure Switch Magnetic Switch X Other (Float Switch) ,Detector samplin(j frecluencT: Evaluation Results Intermi,ttent ); Contin,uous The detector described above was tested for its ability to detect test liquids in contact with the point sensor. The following parameters were determined: · Detection Accuracy - The measure of sensor response to the presence of liquids. · Response Time - Amount of time the detector must be exposed to liquid before it responds. · Recovery ~me - Amount of time that passes before the detector returns to its baseline reading after the test liquid is removed. · Lower Detection Limit - The smallest liquid concentration that the detector can reliably detect. · Product Activation Height - The height of liquid to cause sensor activation. · Specificity - Indicates the level of response, of the detector, to several different liquids. I Carnegie Mellon Research Institute. Test Procedures for Third Party Evaluation of Leak Detection Methods: Point Sensor Liauid Contact Leak Detection Systems: Final Report - November 11, 1991. Liquid Contact Product Detector- Results Form Page 1 of 2 ~, Liquid Contact Product Detector UST Monitoring System' Models. ILS 350 (Beta o13~ ~ TLS 350 ...... Version~ ,...,~ with Interstitial Liquid Sensor for Steel Tanks (0794390r4;~0) Evaluation Results (continued) > Complied Test Results for Qualitative Detector Test ProdUct Flow Rate: 0.12 _+ 0.003 gal/hr. Product Response Detection Activation Time Recovery Accuracy Height at a Flow Rate of Time 0.12 ± 0.003 gal/hr Regular Unleaded 1.42 ± 0.03 in 6.51 ± 0.06 min < 1 rain Commercial Gasoline 100% (3.62:1:0.08 cm) (6 tests [104%]' Synthetic Fuel 100% 1.48 :!: 0.02 in 5.85 + 0.11 rain < 1 rain , (3 tests) , (3.77 ± 0.06 cm) [98%]' Diesel Fuel 100% 1.39 ± 0.02 in 5.81 ± 0.05 min < 1 rain (3 tests) - _ (3.53 :t: 0.06 cra) [98%)" Home Heating Oil 82 100% 1.39 ± 0.02 in 5.88 ± 0.06 min < 1 min (3 tests) (.3_.53 ± 0.06 cra} ::-~ [87%]' Water 100% 1.23:1:0.02 in < 1 rain (3 tests) (3.13 ± 0.06 cm) 5.48 ± 0.04 min ' Specificity Reference: Regular Unleaded Commercial Gasoline I Product Activation Height - Calculated Test Fuel Lower Detection Limit tor 95% I 5% Condltlon Regular Unleaded Commercial Gasoline 1.64 in (4.17 cra) > Safety disclalmer:.This test procedure only addresses the issue of the method's ability to detect the presence of liquid product. It does not test the equipment for safety hazards. Certification o~ Results I certify that the point sensor liquid contact product detector was operated according to the vendor's instructions and that the evaluation was performed according to the Third Party Procedures developed according to the U.S. EPA's "Standard Test Procedure for Evaluating Leak Detection Methods: Liquid-Phase Out-of-Tank Product Detectors."1 I also certify that the results presented above are those obtained dudng the evaluation. Mamaret Nasta. Ph.D. (printed name) (signature~) ~/ ~uly 17, 1992 (date) Liquid Contact Product Detector- Results Form Carn. eqie Mellon Research Institute ** (organization pedorming evaluation) Pfttsbu~h. PA 15213 (city, state, zip) (412~ 26~ (phone number) ** Consultant to the Manufacturer Page 2 of 2 California Edition: June 1999 Veeder-Root TLS-350 Series, TLS-300/300i Discriminating Dispenser Pan Sensor (794380-322) and Discriminating Containment Sump Detector: Output type: Sampling frequency: Operating principle: Sensor (794380-352) LIQUID-PHASE INTERSTITIAL DETECTOR qualitative continuous product permeable, reed switch/float Test Results: polymer strip Discriminating Containment Sump unleaded Sensor gasoline Accuracy (%) 100 Response time (rain) ~10 Recovery time (mia) 17.2 Lower detection limit - height (em) N/D Lower detection limit - thickness (cra) 0.0127 float switches water die,e! Iow high 100 100 100 2-12 hrs <1 sec <I sec 17.2 <1 sec <1 sec N/D 3.48 31.2 0.0127 N/A N/A Discriminating Dispenser Pan Sensor Accuracy (%) Response time (rain) Recovery time (rain) Lower detection limit - height (em) Lower detection limit - thickness (em) polymer strip float switches unleaded water gasoline die~el D.w high 100 100 100 100 ~10 2-12 hfs <1 sec <1 sec 17.2 17.2 <1 sec <1 sec N/D N/D 3.43 19.4 0.0127 0.0127 N/A N/A Specificity Results: Activated: commercial gasoline, synthetic gasoline, diesel fuel, jet-A fuel, n-hexane, toluene, xylene(s), water Not activated: polymer strip sensor did not respond to water Comments: EPA and many states requ/re detection of 1/8 inch (0.32 cm) of product for groundwater monitoring. · Test procedures were modified by evaluator using EPA's "Standard Test Procedure for Evaluation Leak Detection Methods: Liquid-Phase Out-of-tank Liquid Product Detectors". Veeder-Root 125 Powder Forest Dr. Simsbury, CT 06070-2003 Tel: (860) 651-2700 Evaluator: Ken Wilcox Associates Tel: (816) 795-7997 Dates of Evaluation: 01/02/95, 06/23/97, 04/20/98 Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. 321 D April 17, 2002 FIRE CHIEF RON F R,~7. E ADMINISTRATIVE SERVICES 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 SUPPRESSION SERVICES 2101 ~H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 326-0576 ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 326-0576 TRAINING DIVISION 5642 Victor Ave, Bakersfield, CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 Pacific Bell 3221 South H Street Bakersfield CA 93304 RE: Necessary Secondary Containment Testing Required by December 3 l, 2002 REMINDER NOTICE Dear Tank Owner/Operator: The purpose of this letter is to inform you about thc new provisions in California law requiring periodic testing of the secondary containment of underground storage tank systems. Senate Bill 989 became effective January 1, 2002. Section 25284.1 (California Health & Safety Code) of the new law mandates testing of secondary containment components upon installation and periodically thereafter, to ensure that the systems are capable of containing releases from the primary containment until they are detected and removed. Secondary containment systems installed on or after January 1, 2001 shall be tested upon installation, six months after installation, and every 36 months thereafter. Secondary containment systems installed prior to January l, 2001 shall be tested by January l, 2003 and every 36 months thereafter. Secondary containment testing shall require a permit issued thru this office, and shall be performed by either a licensed tank tester or licensed tank installer. Please be advised that there are only a few contractors who specialize ahd have the proper certifications to perform this necessary testing. For your convenience, I am enclosing a copy of the code for you to refer to. Once again, all testing must be done under a permit issued by this office. Should you have any questions, please feel free to contact me at 661-326-3190. Steve Underwood Fire Inspector/Environmental Code Enforcement Officer SBU/dm enclosures CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3rd Floor, Bakersfield, CA 93301 FACILITY NAME 0dC,~[c ~e..tl ADDRESS ,'~[~ \ '..'~. "' -~ FACILITY CONTACT ~SPECTION TIME INSPECTION DATE PHONE NO. ,gqg ' qt g3'-' BUSINESS ID NO. 15-210- NUMBER OF EMPLOYEES Section 1: Business Plan and Inventory Program Routine ~ Combined [~ Joint Agency ~ Multi-Agency ~.~ Complaint ~ Re-inspection OPERATION C VI COMMENTS Appropriate permit on hand Business plan contact information accurate Visible address ..... ~ / ...... Correct occupancy ~ / ...... Verification of inventory materials Verification of quantities Verification of location Proper segregation of material Verification of MSDS availability ~, /' 'Verification ' , of Haz Mat training Verification of abatement supplies and procedures L / Emergency procedures adequate ~.. Containers properly labeled L Housekeeping Fire Protection Site Diagram Adequate & On Hand C=Compliance V=Violation Any hazardous waste on site?: Explain: Yes ~No Questions regarding this inspection? Please call us at (66 i) 326-3979 White - Env. Svcs. Yellow - Station Copy Pink - Business Copy CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3ra Floor, Bakersfield, CA 93301 Section 2: Underground Storage Tanks Program [] Routine ~ Combined [] Joint Agency Type of Tank Type of Monitoring INSPECTION DATE [] Multi-Agency ~2[ Complaint Number of Tanks Type of Piping ~1 [221 Re-inspection OPERATION C V COMMENTS Proper tank data on file Proper owner/operator data on file Permit fees current Certification of Financial Responsibility Monitoring record adequate and current Maintenance records adequate and current Failure to correct prior UST violations Has there been an unauthorized release? Yes No Section 3: Aboveground Storage Tanks Program TANK SIZE(S) AGGREGATE CAPACITY Type of Tank Number of Tanks OPERATION Y N COMMENTS SPCC available SPCC on file with OES Adequate secondary protection Proper tank placarding/labeling Is tank used to dispense MVF? If yes, Does tank have overfill/overspill protection? C=Compliance ,oV=Violation Y=Yes N=NO Office of Environmental Services (805) 326-3979 White - Env. Svcs. Pink - Business Copy B/u s~ne ~p/S i/Respon stble Party TAIT Environmental Systems General Contractors · CA Lic. #588098 June 1,2001 CERTIFIED MAIL - RETURN RECEIPT REQUESTED Mr. Steve Underwood Bakersfield City Fire Department 1715 Chester Avenue, 34 Floor Bakersfield, CA 93301 RE: Pacific Bell Sites & CLLC Codes: 3221 S. "H" Street, Bakersfield CLLC Code: BKFDCA14 Dear Mr. Underwood: Enclosed are the following forms for the above-referenced facilities: * U.S.T & A.S.T Monitor Certification Form Feel free to call if you have any questions. CLB Enclosures :\tes~pb2OOl~letters~kem\underwood.s 1 CC: Stan Brodecki Harry Dyck (Post At Site) Very Truly Yours, TAIT ENVIRONMENTAL SYSTEMS CHERI L. BREWER Office Manager 701 North Parkcenter Drive · Santa Aha, California 92705 · (714) 560-8222 · (714) 560-8237 fax Regional Offices: San Diego- Concord- Sacramento- Phoenix · Tucson www. TAIT.com Authority Cited: MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Chapter 6. 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. Instructions are printed on the back of this page. A. General Information Facility Name: PACIFIC BELL Site Address: 3221 S. "IF' STREET City: BAKERSFIELD Bldg. No.: BKFDCA14 Zip: Facility Contact Person: STEVE PARKS Contact Phone No.: (661) 337-1106 Make/Model of Monitoring System: VEEDER-ROOT TLS-350 Date of Testing/Service: 4/4/01 B. Inventory of Equipment Tested/Certified Check the, appropriate boxes to indicate specific equiPment ins Tank ID: 333 [~In-Tank Gauging Probe: [Annular Space or Vault Sensor: []Piping Sump/Trench Sensor (s): FIFill Sump Sensor (s): [3Mechanical Line Leak Detector. [-IElectronic Line Leak Detector I~lTank Overfill/High-level Sensor: [3Disp. Containment Sensor(s): [3Shear Valve(s): Model: 847390-107 Model: 794390420 Model: 794380-322 Model: Model: Model: Model: 790091-001 Model: [3Dispenser Containment Float(s) and Chain(s): FIOther, Specify equip, type and model in Section E on Page 2 Tank ID: I'-Iin-Tank Gauging Probe: Model: [3Annular Space or Vault Sensor: Model: ['3Piping Sump/Trench Sensor (s): Model: F1Fill Sump Sensor (s): Model: [3Mechanical Line Leak Detector. Model: FIElectronie Line Leak Detector Model: F1Tank Overfill/High-level Sensor: Model: F1Disp. Containment Sensor(s): Model: F1Shear Valve(s): FIDispenser Containment Float(s) and Chain(s): [3Other, Specify equip, type and model in Sect, ion E on Pa~e 2 ected/serviced: TankID: Flin-Tank Gauging Probe: Model: FlAnnular Space or Vault Sensor Model: [3Piping Sump/Trench Sensor (s): Model: [3Fill Sump Sensor (s): Model: E]Mechanical Line Leak Detector. Model: [3Electronic Line Leak Detector Model: [3Tank Overfill/High-level Sensor: Model: V1Disp. Containment Sensor(s): Model: [2Shear Valve(s): [3Dispenser Containment Float(s) and Chain(s): [3Other, Specify equip, type and model in Section E on Page 2 Tank ID: F'lin-Tank Gauging Probe: Model: [3Annular Space or Vault Sensor Model: F1Piping Sump/Trench Sensor (s): Model: [3Fill Sump Sensor (s): Model: [3Mechanical Line Leak Detector. Model: F1Electronic Line Leak Detector Model: IDTank OverfilFItigh-level Sensor: Model: [3Disp. Containment Sensor(s): Model: F1Shear Valve(s): IDDispenser Containment Float(s) and Chain(s): EIOther, Specify equip, type and model in Section E on Page 2 Technician Name (Print): Testing Company Name: Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Site Plan showing the layout of monitoring equipment .For .any equipment. capable of generating such'reports, I h~ve also. attached a copy of the (check all that apply): : I-3 System set-up report; [3[Alarm~istory report. DON S. THOMPSON Cert./Lie. No.: 545-92-3354 Signature: TAIT ENVIRONMENTAL SYSTEMS PhoneNo.: (714)560-8222 Monitoring System Certification Site Address: 3221 S. "H" STREET, BAKERSFIELD Date of Testing/Servicing: 4/4/01 D. Results of Testing/Servicing Software Version Installed: 120.00 Complete the following checklist: []' Yes [] No* Is the audible alarm op .emtional? [] Yes [] No* Is the visual alarm.operational? [] Yes [] No* Were all sensors visually in. spected, functionally tested, and confirmeci'operational? [] Yes [] No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? [] Yes [] NO* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) [] N/A operational? '[]'Yes' [] N~'* For pressurized piping systems, doe~ the turbine automatically shut down if the piping secondary containment [] N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) [] Sump/Trench Sensors; I-IDispenser Containment Sensors. · Did you confirm positive shut-down due to leaks and sensor failure/disconnection? [] Yes; [] No. [] Yes [] No* For tank systems that utilize the monitoring system as the primary tank overfill warning 'device (i.'e. no [] N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly?. If so, at what percent of tank capacity does the alarm trigger? ???..?% [] Yes* [] No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. [] Yes* [] No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) [] Product; [] Water. Ifyes, describe causes in Section E, below. [] Yes [] No* Was monitoring system set-up reviewed to ensure proper settint~s? 1~ Yes [] No* Is all monitoring equipm,ent operational per manufacturer's specifications~? * In Section E below describe how and when these deficiencies were or will be corrected. E. Comments: Monitoring System Certification Site Address: 3221 S. "II" STREET, BAKERSFIELD F. In-Tank Gauging / SIR Equipment: Date of Testing/Servicing: 4/4/01 [] Check this box if tank gauging is used only for inventory control. [] Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Com fiete the following chec,klist: . [] Yes [] No* I~ all i~Put wiring be~n inSPected for proper entry and termination, including testing fOr ground faults? []'yeS [] N°* Were all tank gauging'probes visually inspected for damage and residue buildup? [] Yes [] No* Was accuracy of system product level readings tested? [] Yes I"1 No* Was accuracy of system water level readings tested? [] Yes [] No* Were all probes reinstalled properly?. [] Yes [] No* Were all items on flae equipment manufacturer's maintenance checklist completed? * In the Section H below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): [] Check this box ifLLDs are not installed. Complete the following checklist: [] Yes [] No* For equipment start'-up or annual equipment certificati°n, was a leak simulated to verify LLD performanCe? [] N/A (Check all that apply) Simulated leak rate: [] 3 g.p.hfi; [] 0.1 g.p.h.2; [] 0.2 g.p.h.2 NoteS: 1. Required for equipment start-up certification and annual certification. 2. Unless mandated by local agency, certification required only for electronic LLD start-up. [] Yes [] No* Were all LLDs confirmed operational and accurate within regUlatory requirements? [] Yes [] No* Was the testing apparatus properly c~librated? [] Yes [] No* For n~ecimnical LLDs, does the LLD'reStrict product flow if it'detects a leak?' [] N/A [] Yes [] No* For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? [] N/A [] Yes [] No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled [] N/A or disconnected? [] Yes [] No* For electronic LLDs, does the turbine automatically shu[ off if any portion of the monitoring system I-I N/A malfunctions or fails a test? [] Yes [] No* For electronic LLDs, have 'all accessible wiring c°nnections been visually inspected? El N/A [] Yes [] No* Were all i~em~ on the equipment manufacturer's maintenance checklist completed? . .. * In the Section H below, describe how and when these deficiencies were or will be corrected. H. Comments: '~ Moh~tori?gSystem Certification UST Monitoring Site Plan Site Address: 3221 S. "H" STREET, BAKERSFIELD Date map was drawn: ~_~/~_~L_/ O/. Instructions If you already have a diagram that shows all required information, you may include it, rather than this page, with your Monitoring System Certification. On your site plan, show the general layout of tanks and piping. Clearly identify locations of the following equipment, if installed: monitoring system control panels; sensors monitoring tank annular spaces, sumps, dispenser pans, spill containers, or other secondary containment areas; mechanical or electronic line leak detectors; and in-tank liquid level probes (if used for leak detection). In the space provided, note the date this Site Plan was prepared. CALM-02 Page __ of __ 11/15/99 CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3rd Floor, Bakersfield, CA 93301 FACILITY NAME ~0~a't-~t~. , get[ ADDRESS ~a[ ---~q. ' .~ II FACILITY CONTACT INSPECTION TIME INSPECTION DATE IO/Iq[O'O PHONENO. 3 qg~ tllf.5''' ' BUSINESS IDNO. 15-210- NUMBER OF EMPLOYEES [~'~ Section 1: Business Plan and Inventory Program Routine [j~ombined I~ Joint Agency [~ Multi-Agency I~ Complaint ~ Re-inspection OPERATION C V COMMENTS Appropriate permit on hand Business plan contact information accurate L,' Visible address Correct occupancy Verification of inventory materials Verification of quantities Verification of location Proper segregation of material Verification of MSDS availability Verification of Haz Mat training Verification of abatement supplies and procedures ~, Emergency procedures adequate Containers properly labeled Housekeeping Fire Protection Site Diagram Adequate & On Hand k~ / C=Compliance V=Violation Any hazardous waste on site?: Explain: [~l Yes [~"No Questions regarding this inspection? Please call us at (661) 326-3979 White - Env. Svcs. Yellow - Station Copy Pink - Business Copy FACILITY NAME {)O~ ~ '~ ~.. CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3rd Floor, Bakersfield, CA 93301 INSPECTIONDATE Ioltq lO0 . Section 2: Underground Storage Tanks Program 121 Routine [~ombined [] Joint Agency Type of Tank hr0 Type of Monitoring [] Multi-Agency [] Complaint Number of Tanks I Type of Piping OO~f= [] Re-inspection OPERATION C V COMMENTS Proper tank data on file Proper owner/operator data on file Permit tees current Certification of Financial Responsibility Monitoring record adequate and current Maintenance records adequate and current ,~/' Failure to correct prior UST violations Has there been an unauthorized release? Yes No D/' Section 3: Aboveground Storage Tanks Program TANK SIZE(S) AGGREGATE CAPACITY Type of Tank Number of Tanks OPERATION Y N COMMENTS SPCC available SPCC on file with OES Adequate secondary protection Proper tank placarding/labeling Is tank used to dispense MVF? If yes, Does tank have overfill/overspill protection? C=Compliance V=Violation Y=Yes N=NO Inspector: ____~_~__1 d_~]_~0 Office of Environmental Services (805) 326-3979 White- Env. Svcs. Pink - Business Copy Busi~ess Site~,gesponsible Party JUN-07-~000 I~PE Ol~ ACT1ON 16:57 PB ENVIRONMENTAL MGMT 925 86? 0241 P.07/0~ UNDERGROUND STORAGE TANKS - FACILITY (onc page per sit:) Pagc] L ~'W stTZ~rr ~} 3. ~WAL ~RMrr C] ~.~ANOI~ OS nWO~,I~TION ~ 7.~Y ~OS~ S~ ~ ~. ~ P~MIT ~d~ ~ I~ u~ only I. FACILITY / SITE INFORMATION FACILITY ID# ,~r, ~ ' " Pacific Bell (SA098) NEAREST CROSS STREET ~o, FACIL/TY-OWNER 'IYPE [] 4. LOCAL AGENCY/DISTRICT* Planz Road BUSINESS [] 1. O~,S STATION [-[ 3. FARM [] 5. COMMERCIAL TYPE [~ 2, DISTRIBUTOR [~ 4, pROCESSOR [] 6, OTHER 403 ~i~OTAL NUMBER OF "rANKS' [ Is facility on lnd{~ Rcscrvm~lon or KEMA~O AT SITE I ttustl{nds? I 4o~ [] Y~s {~ No ~o~ PKOPERT~r b~,lER NAME Pacific Bell (SA098) qViAILI1VG OK STREET ADDgEgS 3221 South H Street [~] 1. COP. POKATION [] 5, COUNTY AGENCY* [] 2. INDIVIDUAL C] 6. STATE AGENCY* [] 3, PARTNEI~HIP [] 7, FEDERAL AGENCY* ~ ~ If ovmer al' UST is a public agcn~; ~me of supervisor of d/vision, sect;on or ott]~ which operates the UST O'his is the comuor persm~ for Ibc tank r~cords,) Bakersfield PROPERTY OWNER TYPE [] I. CORPORATION PROPERTY OWNER iNFORMATION { PHONE (800) 757-6575 4~9 412 ,~0 { STATE 4~1 { ZIP CODE cA { U['2. INDIVIL~UAL [] 4. LOCAL AGENCY/'ISIsTRiCT ~ ~. ?AgTNE~HI? ~ S. COUNTY AGENCY 'Il 6~ STATE"AGENCY [] 7. FEDERAL AGENCY -TANK OgfNER NAME Pacific Bell ($A098) MAILING OK STI~ET ADDRESS PO Box 5095, Room 3E000 CITY San Ramon -TANK OWNER TYP[~ -TY (TK) HQ 44- IH. TANK OWNER INFORMATION IPHONE , (aGO) 757-6575 .~7 [ [ZiPCODE CA 94583-0995 [] 1. CORPORATION [] ~, [NDIVIDUAE [] 4. I~OCAL AGENCY / DISTRICT [] '6. STATE AGF,~CY [] 3. PARTNERSHIP [] 5, COUNTY ~OENCY [] 7, FEDERAL AGENCY IV. BOARD OF EQUALIZATiON UST STORAGE FEE ACCOUNT 1VUb~ER '{ I { 9 { ! { 4 { ., Call (916) 322-9659 if questions arise V. PETROLEUM UST FINANCIAL RESPONSIBILITY 419 a2o 421 INDICATE METHOD(s) [] l. SELF-INSURED [] 2. GUAgANTEE [] 3. INSURANCE [] 4. SURETY BOND [] 7, STATE FUND [~ 5. LI~TTER OF CREDIT [] 8. STATE FUND & CFO LETTER [] 6. EXEMlrI'ION [] 9. STATE FUND & CD r']10. LOCALGOYTMECHANISM []99. OTHER: _ VI. LEGAL NOTIFICATION ~dVI)'MAILING ADDRESS Ch~ck m*m box ~0 indicate which addr¢~z aaould tn: u~i for lcgal nolfficadon~ arid mailing. ~ no~fla~ ~ mailings ~11 be ~[ to ~c t~k o~cr unless ~x 1 or 2 ~. ~LIC~ SIGNA~ -SI~'URI/OF APPLICAN;F '~ N,~[,tE OF APPLICANT (Print) Armi D. Strickland -STATE UST FACILITY NUMBER. (Fo~ 10~.1 ~e only) UPCF (1/99 revised) DATE 4~4 { PHONE *;s 06/07/2000 t ($00) 75%6575 TITLE OF A~PPLICANT 4~ Environmental Associate 1998 UPOILM)B CERTIFICATE NUMBER (~or local u~ %y) ~:~ · Forme.~,ly SWKCB Form A JUN-O?-2000 i6:58 PB ENUIRONMENTAL MGMT 925 869 0241 P,08/08 ~D PROGRAM CONSOLIDATED FOI~V~ TANKS UNDERGROUND STORAGE TANKS - TANK PAGE 1 (two pages pet tank) ~ OF ^CTION [] I N~W $1T~ I~RMIT [] 4 ~£D P£RM~T [] 5 CHANOE OF INFORMATION [~ 6 TEM~O~Y $1T~ CLOSURE (Cherk o~ )mm n~ly) [] 7 PERMANENTLY CLOSED ON SITE [] 3 KENEWALPERMIT ($~ty~o~-torlo,~u$~o~l~) (s~.=i,'~.~on-r¢=l~lu~ody) [] 8 TANKRF.2dOVED . 17T~K DESC~PTION (A ~c~ed plot pl~ wi~ ~*'lo~fion of ~ ~gT]y's~m including buiMi~gs ~d i~dm~ks ~hall ~ ~ubmi~d t~ ~e locfl ~ency.) T~K ID ~ 4~z T~K MANUgX~U~R 4~ COMPA~E~~ T~K ~ Yes ~ N0 ~ATE ~ST~LBD (Y'gA~MO) ~5 TANK c~ACITy IN GAL~'NS 41~-, NUMBER OF COnSTaNTS .... 1988 5,000 ~ T~K CO~NTS IIL TANK CONSTRUCtiON ~OFT~ ' ' ~ ITS~GLEW~L ~, 5~G~w~TH ~ 5~ 5~GLEW~LWI~~B~D~SYST~ ~2. DO~W~L ~4. SlONL~WALL~ VAST ~99. O~ (c~ko~i~ofl]~) ~2. ST~SSS~ ~4, ~L~DW~iRERG~ ~g. ~CO~LEW/100%~OL ~99. O~~ R~OR~ P~$HC ~ ~ 2. ST~S5 S~L ~. S~LCLAD W~G~ ~ K ~ CO~W/lO0%~OL ~ 99, O~~ OR coaT~o ~ 2 ~ ~O ~ 4 PI~NO~C b~lNO ~ 6 ~b ~ ~ ~W ~O~C~ON IF APPLICABL~ PROLCON ~ 4 ~SS~ C~ ~ 99 O~ (Ch~ one i~ o~ly) ~ 2 SAC~CIAL ANODE ~=r ~al ~= only) (~kaU~a~*pply) ~ ] SP~ CONTA~M~T 198B ~ I ~ ~ 3~ES~O~V~VE 1988 ~ 2 DROP T~F 1988 ~ 2 BALL ~AT ~ ~ 4 ~X~ ~ ~ STOKER P~TE 198~ (Ch~k ~c hem only) ~ l ~SU~ ~S~ ~R~ON O~ ~ 5 ~ TA~ OAUO~O ~TO) ~ l ~U~ (S~OLE W~L ~ VAST ONLY) ~ 2 A~C TANK OAUO~O (ATO) ~ 6 V~OSE ~ ~ 2 CO~OU$ ~S~L MONHO~G UPCF (1/99 r~vised) 10 Form~i~ SWRCB Form B SINGLE WALL PIPING ]~E'~SUI~b~'~r~ F/PING (Che~k nJI ~t ~ 1. ~O~C L~ ~ DEBTOR 3.00PH ~ST 0~ ~R L~, SYS~ F~UgE, ~ ~YSTEM D~C0~0N + A~mL~ ~ VISU~ ~ 2. ~O~Y 0.1 GPB ~X CONVEN~ONAL SUCTION sYSTEmS ~ 5. DAVY VISUAL MO~G OF S~ SUC~ SYS~MS ~O V~S ~ BELOW GROUPinG); ~ 7. SELF MO~MNO G~VI~W SINGLE WALL Fi_PING pP, F~SLrRI2ED PIPINO (C.h~k ~11 fi, aL ~{~ply): [] 1. ELI~CTROIqlC ~ LEAK DE~R 3.0 GPH TEST WiTH AUTO PUMP SHUT OFF FOR LEAK, SYSTEM FAR.UP.E, AND SYS'I'~M DI$COI~4'ECTION + AUDmLE,,,~D VISUAL [] 2. MONTHLY 0.2 GH.I TEST [] ~. ANh~AL I~mogiTY TEST (0. mPH) [] 4. DAILY vISUAL COKVENTIONAL SUCTION sYSTEMS (Ch~k .ti tha~ [~ $. DAILY VISUAL MONITOK1NG OF Pn~ING AND pUlV~PING SYSTF_,M ["9 6. TPJENNIA~ ]NTEGP, ITY TP_~T (0.1 GI, H) SAFE SUCTION SYSTBM5 (NO v~.LVE$ IN BELOW GROUI4~ PIPING): [] 7. SELF MONITORING GRAVITY FLOW (Ch~k all ~ qmply): [] 8. I~'JLY VISUAL ~ 9. B~lqlqlAL IN'IT~OKI'Ff TEST (o,1 OM,~') SECONDARILY CON-fA[NED PIPING PR]SSS~ PIPING (ch~k ~,11 that apply): 10. CONTINUOUS TURBINE SUMP SENSOR ~WITH AUDI~LE AND VISUAL ALARMS AND (Cheer 1'3 a AUTO PUMP SHI.~ OFF W'HEN A LEAK OCCURS ~ b AUTO PUMP 81-ILrr OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM DISCObINECI'ION O~ NO AUTO PU'MP SHUTOFF [] ! 1. AUTOMATIC LEA~ DETECTOR [] ~2. ANNUALINT~RfI~TEST(O.I OPH) SUCTION/GIm,&VITY SYSTEM. {-{ i3. CONTINUOUS SUMP SENSO~R + AUDIBLE .~ VISUAL EMERGENCY GENERATOI~ ONLY (Ch~ ~11 ~.mt,pply) ~ 14. CONTINUOUS SUMP SENSOR WITHOU~T AUTO F/rMP SHUT OFF ^UDI~LE AND VISUAl, ALA.R~5 [] 15. ^UTOMATIC LL~B LEAK DETF-CTOR 0-o OPH TEST) [~ {6. ANNUAL INTEGRITY TEST (0.1 [~ 17. D^n~Y VlSUAt. C~ECK SECONDARILY cONTAIN ED PIPING PRESSURIZED PIPING (ch~k nil ~at co~ous ~ s~ s~soR ~A~mC~ ~ vlgu~ ~5 A~ (ca~ ~ A~ ~ S~TO~ ~ A~ 0~ ~ ~. A~O P~ 8~ O~ FOR L~S, 9YS~ F~ ~ ~YS~ DISCO~ON ~c. NO A~ P~ SHUT O~ I L AU~C ~ ~ D~R (3.0 G~ OFF OR 5U~ON/~V~ 13. COPIOUS S~ S~SOR + A~ A~ ~U~ ~S KM~GEN~ GENE~TORS ONLY (Ch~k AuD~ ~ VISU~ ~ 15. A~O~C ~ ~ D~OR (3,0 O~ ~S~ ~O~ ~OW 5~ O~ OR ~C~ON 16, ~ ~G~ ~ST (O.l [] 17. DALLY vISUAL CHECK VIII, DISPENSER CONTAINMENT DISPE~S]~. CONTAII,~MEblT [] 1. FLOAT I~CHA.NISM TI-~T SFfUTi OF~ SBEAR VALVE ~ 4, DA~LY VISUAL ~ DATE INSTA~ ~ 46. [] 2. COb~r[NUOU~ DISPENSER PAN SENSOR + AUDIBLE AND VISUAL ALA~.~S [] 5. Ti~qCH Llt~El~ I MONITOR] NG [] 3. CONTINUOUS D1SI~NSE~. PA-.~ S~I~SOK ~ AUTO SH-~r~ OFF FOR ~ 6, ~10~4~. 4o9 D~SPENSER + AUDIBLE A~D VISUAL ALAgMS I~. OWNER/OPERATOR SIGNATURE Armi D. S~'ickland l~[tNumb&~' (Fe~ Io~l u,e only) UPCF (1/99 revised) DATE 470 "1 06/07/2000 ~ 1 TITt.~ OP O'~,,1ER/OPF_KATOR ~nvirom-ncn~l As$ociat~ Fo~ly S~CB F~ B TOTRL P,08 Site Location: County: Environmental Management P.O. Box 5095 Pacific Region Room 3Eggo San Ramon, CA 94583 UST & AST MONITOR CERTIFICATION FORM PACIFIC BELL 3221 S. "H" STREET BAKERSFIELD KERN Make & Model of Monitor System(s): Serial # of Monitor System(s): Testing Date: 4/4/00 Next Due Date: 4/4/01 Tank ID(s): 333 CLLC Code: BKFDCA14 Geo Parcel: SA-098 Site Contact: HARRY DYCK Site Contact Phone #: 559-454-3003 VEEDER-ROOT TLS-2501 22757 Tank ID # Type of Tank: (Single Wall or Double Wall) UST or AST Tank Material (Composite, Fiberglass, etc.) Contents of Tank: Capacity of Tank: Type of Product Line: (Gravity, Suction, Pressure) Type of Piping: (Single Wall or Double Wall) Tank 1 Tank 2 Tank 3 ' ~ank 4 333 DW/UST COMP DIESEL SUCTION DW ALL SYSTEMS Annular Space Sensor: Fill Sump Sensor: Piping Sump Sensor: Piping Trench Sensor: Dispenser Containment Sensor: Other Types (sensors): Tank 1 Tank 2 Tank 3 Tank 4 Sensor Type (Float, Discdm, etc. PASS N/A PASS N/A 'N/A ' , Compartmer~ted Tank(s) J Type of Overfill Protection (mechanical, electronic, ball float) BALL FLOAT, ELECTRONIC Type of Spill Containment (Make & Model) FOR PRESSURE TYPE SYSTEMS ONLY EBW FLEX CATCH 5 GALLONS Is Mechanical Line Leak Detector Present & Tested?: Does the Turbine Shut-Down if System Detects a Leak?: Does Positive Shut Down Occur if Monitor System is turned off?.: ALL SYSTEMS In-Tank Gauge Present. Probe Type and Type of Leak Detection (Ex..2 gph). Does the Monitoring System have Audible & Visual Alarms? Is the Monitoring System installed to prevent unauthorized tampering?: Is the Monitoring Devices operable as per manufacture's specifications? Tank 1 Tank 2 Tank3 Tank4 YES CAP .2 GPH DALLY YES YES YES Date: 4/4/00 Certified Tester;s ID #: 92-3,354 Testing Company: Technician: TNT ENVIRONMENTAL SYSTEMS DON S. THOMPSON ~rin, u~t N.~,e)"~..~ (Signature) April 20, 20O0 City of Bakersfield Mr. Ralph E. Huey Director-Enviromental Services 1715 Chester Avenue, 3ra Floor Bakersfield, California 93301 Environmental .Management Pacific Region P.O. Box 5095 Room 3E000 San Ramon, California 94583 RE: Financial Test of Self Insurance (Underground Tanks) The attached is a copy of our Chief Financial Officer Letter to demonstrate financial responsibility for Pacific Bell's underground storage tanks. Please call me on (925) 823-6161 if you have questions regarding this correspondenc~ Stan Brod¢cki Senior Environmental Manager SBC Environmental Management Attachment ^pril lq, 2000 State Water Resources Control Board Division of Clean Water Programs Underground Storage Tank Cleanup Fund · 2014 T Street, Suite 130 Sacramento, CA 95814 Re: Financial Test of Self-Insurance CtJnderground Tanks) I am Senior Vice President & Chief Financial Officer of Pacific Bell Telephone Company, 140 New Montgomery St., San Francisco, California. This letter is in support of the use of the financial test of serf-insurance to demonstrate financial responsibility for taking corrective action and/or compensating third parties for bodily injury and property damage caused by sudden accidental releases and/or non-sudden accidental releases in the amount of at least two million dollars annual aggregate arising from underground storage tanks. Underground storage tanks at Pacific Bell facilities are assured by this finaiacial test or a f'mancial test under an authorized State Program by this owner or operator. A financial test is also used by this owner or operator to demonstrate evidence of financial responsibility in the following amounts under other EPA regulations or State programs authorized by EPA under 40 CFR Parts 271 and 145. EPA Regulations Closure (§§ 264.143 and 265.143) ........................................................ Post-Closure Care (§§ 264.145 and 265.145) ........................................ Liability Coverage (§§ 264.147 and 265.147) ....... : ............................... Corrective Action (§§ 264.101 (b)) ....................................................... Plugging and Abandonmem (§§ 144.63) ............................................... Closure ................................................................................................... Post-Closure Care .................................................................................. Liability Coverage ................................................................................. Corrective Action ........................................................ . .......................... Plugging and Abandonment ................................................................... Total ....................................................................................................... Amount $400,000. $100,000. $2,000,000. $100,000. SN/A $7,400,000. $1,000,000. $2,OO0,0OO. $3,700,000. $I50,000. $16,850,000 This owner or operator has not received aa adverse opinion, disclaimer of opinion, or a "going concern" qualification from an independent auditor on his financial statements for the latest completed fiscal year. Alternative 1 (Source: Form 10K, December 31, 1997) 1. Amount of ann~al UST aggregate coverage being assured by a f'mancial test, and/or guarantee ......... 2. Amount of corrective action, closure and post-closure care costs, liability coverage, plugging and abandonment costs covered by a financial test, and/or guarantee .......................................................... 3. Sum of lines I and2 ................i .............................................................................................................. 4. Total tangible assets ............................................................................................................................... 5. Total liabilities (if any of the amount reported on line 3 is included in total liabilities, you may need to 7. 8. 9. 10. Have financial statements for the latest fiscal year been filed with the Energy Information Admin... 11. Have financial statements for the latest fiscal year been filed with the Rural Electrician Admin ....... 12. Has financial information been provided to Dun and B~adstreet and has Dun and Bradstreet Provided A financial strength rating ora 4A or SA? $ 2,000,000. $16,850,000. $18,850,000. $15,938,000,000. Deduct that amount fi.om this line and add that amount to line 6) ......................................................... $13,219,000,000. Tangible net worth (line 4 minus line 5) ................................................................................................ $ 2,719,000,000. Is line 6 at least $10 million? .................................................................................................................. Yes Is line 6 at least 10 times line 3? ............................................................................................................. Yes Have financial statements for the latest fiscal year been filed with the Securities and Exchange Commission? .......................................................................................................................................... Yes N/A N/A (answer "yes" only if both criteria have been met) ................................................................................ Yes I hereby certify that the wording of this letter is identical to the wording specified in 40 CRF part 280.95 (d) as such regulations were constituted on the date shown immediately below. Sincerely, Randall Stephenson Senior Vice President & Chief Financial Officer Date: I State of California '";ForSta~.UseOnly ' State of Water Resources Control Board !(ii?. c~':.u...,,,:.,..' ...... .: Division of Clean Water Programs ..'.:'~:,,.~ ~:*-,::'.;';' .-' , ' P.O. Box 944212 .,. ~:;?,~:? ;:~,~:.,:~ .~,:. ~. Sac~ncnto, CA 94244-2120 0ns~ctions on ~vc~c side) ':;.~?~{:?~{?;:~'4~?~,'5 ' ,' ' :';,c' ~,'.~: 7' ?.~': CERTIFICATION OF FINANCIAL RESPONSIBILITY FOR ~ERGROU~ STOOGE T~ CONTA~G PETROLEUM A. I ~ requir~ to demon~te F~ci~ R~mibiliF ~ ~e R~u~ ~o~ m ~ified ~ S~tion 2807, Chapter 18, Div. 3, Title 23, CCR: ~ 500,000 doll.s per occu~ence ~ 1 million doll~ ~nual aggregate or ~ or ~ I million doll.s per occu~ence ~ 2 million doll~ ~nuai a~regate B. Pacific Ball bo~by co~s ~at ff is in complianco wffh tho ~quimmonts of 8oction 2~07, (Namo og tank ~ner or 0~ A~iclo 3, O~aptor ~ & Division 3, ~tlo 23, Cal~omia ~o ot R~ula~ons. Th~ mechanisms usod to domonstmto ~nancial msponsibili~ as mquimd by 8oction 2807 am as gollows: ~N a m e~'afi~A~ms~l~:j~ ~u~ SBC Environmental Management Not Appli~ble Chief Financial Pacific Region For State Renewed Officer Le~er PO Box 5095, Rm 3E000 Altemative $16,850,000 Annually Yes Yes (affached) ~an Ramon, CA ~58~0995 Mechanism Note: If you am using the State Fund as any pa~ of your demonstration of financial msponsibili~, your execu~on and submission of this cedification also ce~ifies that you am in compliance with afl conditions for pa~icipation in the Fund. D. Facili~ Name Facil~ Address Pacific Bell See Affached List Facili~ Name Facili~ Address Facility Name Facili~ Address E. Signature of Tank ~ner or Operator Date Name and Title of Tank ~ner or Operator J~~~3 9/~//0~ Start Brodecki, Senior Environmental Manager Signture of ~tness or Nota~ Date Name of ~tness or Nota~ CFR ([ evised 04195) FILE: Original - Local Agency Copies - Facility/Site(s) 2000 UST FINANCIAL RESPONSIBILITY KEPd,,I COUNTY Location ~ Bakersfield Fire Dept 1918 "M" Street ;Bakersfield Bill Keenan Bakersfield Fire Dept 3501 Columbus Ave Bakersfield I Bill Keenan Bakersfield Fire Dept 3221 So. "H" Street Bakersfield !Bill Keenan Bakersfield Fire Dept 11609 Rosedale Hwy Bakersfield f Bill Keenan Bakersfield Fire Dept 11101 White Lane Bakersfield Bill Keenan Bakersfield Fire Dept 5650 Aldrin Ct Bakersfield ~Cindy Maddgal Kern County Health Dept 925 Jefferson St Delano Bill Keenan Kern County Health Dept 8313 E Segrue Road Lam0nt IBill Keenan Kern County Health Dept 1021 California St OildaleI Bill Keenan TAIT Environmental Systems General Contractors · CA Lic. #588098 U.S.T. & A.S.T. MONITOR CERTIFICATION FORM Site Location: PACIFIC BELL 3221 SOUTH "H" STREET BAKERSFIELD County: KERN Make & Model of Monitor System(s): Testing Date: 4/6/99 Tank ID(s): 333 CLLC Code: BKFDCA14 Geo Parcel: SA-098 Site Contact: DELTON DAVE Site Contact Phone #: (559) 784-0010 VEEDER-ROOT TLS-2501 Tank ID # Type of Tank: (Single Wall or Double Wall) UST or AST Contents of Tank: Capacity of Tank: Type of Product Line: (Gravity, Suction, Pressure) Type of Piping: (Single Wall or Double Wall) Tank 1 Tank 2 Tank 3 Tank 4 333 DW/UST DIESEL 5,036 SUCTION DW INDICATE THE SENSORS TESTED BY PLACING A YES, NO, OR N/A & PASS OR FAIL IN CORRESPONDING BOX: Annular Space Sensor: Fill Sump Sensor: Piping Sump Sensor: Piping Trench Sensor: Dispenser Containment Sensor: Problems System(s) Tank 1 Tank 2 Tank 3 Tank 4 Sensor Type PASS PASS FOR PRESSURE TYPE SYSTEMS ONLY: Tank 1 Is Mechanical Line Leak Detector Present & Tested?: Does the Turbine Shut-Down if System Detects a Leak?: Does Positive Shut Down Occur if Monitor System is turned off?: Tank2 Tank3 Tank4 Is Tank Level Gauging System Present. Probe Type if Applicable. Type of In-Tank Leak Detection Test Performed by Monitor: Does the Monitoring System have Audible & Visual Alarms? Electronic Overfill/Level: Is the Monitoring S×stem installed to prevent unauthorized tampering?: ~ Is the Monitoring Devices operable as per manufacture's sPecifications? YES CAP 2.0 GPH DAILY YES YES 90% YES YES Date: 4/6/99 Certified Tester's ID #: 92-3354 Technician: DON S. THOMPSON · flint Nl~me,)fl,~.,. ~. (Signature) 701 North Parkcenter Drive · Santa Ana, California 92705 · (714) 560-8222 · (714) 560-8237 fax Regional Offices: San Diego. Concord · Sacramento · Phoenix · Tucson www. TAIT.com Corporate Real Estate 2600 Camino Ramon San Ramon, California 94583 PACIFICI:IrBELL ~ A Pacific Telesis Company APR 2 2 1999 City Of Bakersfield Ralph E. Huey Director Env. Svcs Fire Department 1715 Chester Ave., 3rd FI Bakersfield Ca 93301 RE: Financial Test of Self Insurance (Underground Tanks) The attached is a copy of our Chief Financial Officer Letter to demonstrate financial responsibility for Pacific Bell's underground storage tanks. ...... Also attached is the annual State of California Water. Resources_Control I ............................. Board's ~-rt]~-~-~``.`Fi~.~h~Ei~FR`e`~5-6F~`§~i~5i~ity~f~TTn--A~-c~ig~.~f~p~[fi~-.B~]~-¥~-~ .......... . ..... ~ ....... sites that have underground tanks on the premises in your area of I ' jurisdiction. Please call me on 925-823-6161 if you have questions regarding this correspondence. Nancy Clancy Pacific Bell Environmental Management attachments Robgrt 6. Pickeripg Ct, el Financial Officer 2600 Cam~no Ramon. San Ramon. Cahfornia {510) 867-280G Fax (510) 867-983 PACIFIC~,I'~ EIELL. A Pacific Teles~s Comoan,, April 13, 1999 State Water Resources Control Board Division of Clean Water Programs Underground Storage Tank Cleanup Fund 2014 T Street, Suite 130 Sacramento, CA 95814 Re: Financial Test of Self-Insurance (Underground Tanks) I am Vice President & Chief Financial Officer of Pacific Bell, 2600 Camino Ramon, Room 4CS100, San .Ramon, California. This letter is in support of the use of the financial test of self-insurance to demonstrate financial responsibility for taking corrective action and/or compensating third pa~..ies for bodily injury and property damage caused by sudden accidental releases and/or non-sudden accidental releases in the amount of at least twomillion dollars annual aggregate arising from underground storage tanks. :Uffdb¥g~6-ui~d storage'~-gt-P~i~-B-e-ii~ac--lli~-e~a~l by-this financial-test-or-a-financial~test .............. under an authorized State Program by this owner or operator. A financial test is also used by this owner or operator to demonstrate evidence of financial responsibility in the following amounts under other EPA regulations or State programs authorized by EPA under 40 CFR Pans 271 and 145. EPA'Regulations Amount Closure (§4 264.143 and 265.143) ........................................................ $400,000. Post-Closure Care (§§ 264.145 and 265.145) ........................................ $100,000. Liability Coverage (4§ 264.147 and 265.147.) ....................................... $2,000,000. Corrective Action (§4 264.101 (b)) ....................................................... $100,000. Plugging and Abandonment (44 144.63) ............. ;i ................................ SN/A - Closure ................................................................................................... $7,400,000. Post-Closure Care .................................................................................. $1,000,000. Liability Coverage .................................................... .'. ............................ $2,000,000. Corrective Action ............................................................................... .'...$3,700,000. Plugging and Abandonment ................................................................... $150,000. Total ....................................................................................................... $16,850,000 . This owner or operator has not received an adverse opinion, disclaimer of opinion, or a "going concern" qualification from an independent auditor on his financial statements for the latest completed fiscal year. State Water Resources Control Board · April 13, 1999 Page Two Alternative 1 (Source: Form 1 OK, Decem~ 31, 1998) 1. Amount of annual UST aggregate coverage being assured by a financial test, and/or guarantee ......... $2,000,000. 2. Amount of corrective action, closure and post-closur~ cate costs, linbili~ coverage, plugging and abandonment costs covered by a financial test, and/or guarantee ............. : ............................................ $16,850,000. 3. Sum of lines 1 and 2 ............................................................................................................................... $15,850,000. 4. Total tangible assets ........................................................................................... : ................................... $15,093,000,000. 5. Total liabilities (if any of the amount ~orted on line 3 is included in total liabilities, you may need to Deduct that amount from this line and add that amount to line 6) ................................................ ; ........ $11,833,000,000. 6. Tangible'net worth (line 4 minus line 5) ................................................................................................ $ 3,260,000,000. 7. Is line 6 at least $10 million? ........................................ ~' ......................................................................... Yes $. Is line 6 at least 10 times line 3? ............. ~ ............................................................................................... Yes 9. - Have financial statements for the latest fiscal~year been filed with the.Securities andExchnnge. C~mmis~i~n? "`:~-.:.~.-.~:~.~...~"~"`~.~;..~:~.~:~..;:~;~..;~-~-`~;~.~;:.~;;;-..-~..~=~;:~ ........ , ..... ::.-::;;-z.::..:::~:.=;....:..,= .... - 'Yes - - 10. Have financial statements for the latest fiscal year been filed with the Energy Information Admin ..... N/A 11. Have financial statements for the latest fiscal, year been filed with the Rural Electrician Admin ........... N/A. 12. Has financial information been provided to Dun and Bradstreet and has Dun and Bradstreet provided A financial strength rating ofa 4A or SA? (answer "yes" only if both criteria have been met) ................................................................................ N/A* *For SBC Communications .Inc. (holding company)...'. .................................... ; ................... Yes I hereby certify that the wording of this letter is identical to the wording specified in 40 CRF part 280.95 (d) as such regulations were constituted on the date shown immediately below. Robert B. Pickering Dated: ~- ~ 'c/t1 II CERTIFICATION OF FINANCIAL RESPONSIBILITY Annually Yes Chief Financial Environmental iln~gemeot Officer Letter PO Box 5095 RM, 3E000T {attached) $;mn ~mmon, CA 94563.0995 $16,850,000 Not Applicable For ~ A~meflve Meohaniem Pacific I~11 See Attached List ncy Clancy I Envimn~l Advisor INSTRUCTIONS CERTIFICATION OF FINANCIAL RESPONSIBILITY · Please type.or print ini'o~~inn cleady..Ali.US'Ii, si~ owned or. operated maybe listed on one..+'onn, DO~ INVORMATION B. : Name ofTank Owner or Operator Name of Issuer M~.hanlsm Number Full name of ~ th~ tank owner or the olm'a~ lndieat~ which sppmv~ _n~,-,~,,,,(s) are bein~ used to show rnan~ial respon.~ility e~er as contained in the ~ t~-Sulalions, 40 CFR Pan 2g0 Subpart H, ~ 2~0.93 ilu,,a~h ~0.107, or Szction 2808.1 Chaplzr la, Div. 3, T~tle 23, CCR (s~c F~,,-,,,'~-~ Reqxm~i~ Guide for mote informalion). number, Letter of Credit number, elf.., ~ If using the State Cleanup Fund, blank. Coverage Amount Indi~al~ mount of~overag~ for ~:h ~ me~nism. If more than one .. mechanism is in~ total must equal 100~ of fmancisl respous~flity for ~_ site. Coverage Period ' .Indi__~__ the effective date(s) ofaH m~hanism.s. State Cleanup Fund ~ is .~;-~-----V~--~'~ ~-. ................................. ~ ~-h~ia-~s lo~--a~--~u-~--~F~-~n-d-~n~i~iig~l~-~~L ............................................................... in the Fund; Corrective Action Indicate yes or no. Does the specified financial assurance mechanism provide coverage for corrective action? It is a required coverage. If using the State Cleanup Fund, indicate "yes." Third Party Compensation Indicate yes or no. Does the specified financial assurance mechanism provide coverage for corrective action? It is a required coverage. If using the Slate Cleanup Fund, indicate 'yes." D. Facility Information .Provide all facility and or site nan, s and addresses. E. Sign. ature Block Provide si~nalu~ and date signed by rank owner or operator;, printed 6r typed name and title of tank owner or operator; si~natore of witness or notary and d~ signed; and printed or typed name ofwimess or notary. (If notary signs pleas~ attach documentation.) Where to Mail certification; Please send original to your 1o~1 qenoy(iss) [agency(ies) that issues the UST permits]. Keep a copy of the certification al each listed site .... If you have questions about financial respous~ility t~luirements or about the Cenifi~alion of Financial Respons~ility fonin, please contact the Stat~ Water ~ Comrol Board, Underground Storage Tank Cleanup Fund at (916) 227-4307. Note: Penalties for Failure to Comair with Financial Rest~onsibilitv Reauirements: Fa/lttr~ to comply may ruult in: l) jeopardiz/ng clahnant eiiEibility for the State Cleanup Fund, and 2) liability for civil penalties of up to $10,000 per day, per underground storage tank, for each day of vinlation as stated in Article ?, Section 252~.76(a) of the California Health and Safety Code. 1999 UST FiNANCItRESPONSIBILITY City ofilakersflekl. ~ 5650Aldrili~C~. ~;- .... ~ Bakersfield Madrigal, Cindy Kern County 1021 California St Bakersfield Dyck, Ham/ (0~) Kern County 3501 Columbus Bakersrmld D~cl~, Ham/ C. ity of Bakersfield. S H Slre~",~ Bakersfield Dyck~ Ham/ C#y of Bakersfield :1918 M Str~,' ' ~ Bakersfield Dyck, Harry Kern.. County 11609 R___,~,__~ Hw,/' B. akersfleld Dyckf, Ham/ City of Bakersfield 11101 White'Ln.~i~ Bakersfield Dyck, Ham/ Kern County 925 Jefferson St Delano D~k~ Ham/ Kern Counb/ 8313 E Se~rue Rd Lamont Dyck,,Ham/ 12 ,0 D February 9, 1999 FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVlCE~ 2101 'H' Street Bakemfield. CA 93301 VOICE (805) 326-3941 FAX (805) 395-1349 SUPPRESSION SERVICES 2101 'H' Street Bakersfield, CA 93301 VOICE (805) 326-3941 FAX (805) 395-1349 PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (805) 326-3951 FAX (805) 326-0576 ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (805) 326-3979 FAX (805) 326-0576 TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 VOICE (805) 399-4697 FAX (805) 399-5763 Pacific Bell 3221 S. "H" Street Bakersfield, CA 93304 RE: Compliance Inspection Dear Underground Storage Tank Owner: The city will start compliance inspections on all fueling stations within the city limits. This inspection will include business plans, underground storage tanks and monitoring systems, and hazardous materials inspection. To assist you in preparing for this inspection, this office is enclosing a checklist for your convenience. Please take time to read this list, and verify that your facility has met all the necessary requirements to be in compliance. Should you have any questions, please feel free to contact me at 805-326-3979. Steve Underwood Underground Storage Tank Inspector Office of Environmental Services SBU/dm enclosure ADDRESS ~l FACILITY CONTACT INSPECTION TIME CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3rd Floor, Bakersfield, CA 93301 INSPECTION DATE PHONE NO. :~9'~" q'D BUSINESS ID NO. I5-210- NUMBER OF EMPLOYEES Section 1: Business Plan and Inventory Program [] Routine [21 Combined [2] Joint Agency [2] Multi-Agency [21 Complaint l~l Re-inspection OPERATION C V COMMENTS Appropriate permit on hand / Business plan contact infbrmation accurate Visible address Correct occupancy Verification of inventory materials Verification of quantities Verification of location ~!~' Proper segregation of material Verification of MSDS availability Verification of Haz Mat training Verification of abatement supplies and procedures Emergency procedures adequate Containers properly labeled Housekeeping Fire Protection Site Diagram Adequate & On Hand C=Compliance V--Violation Any hazardous waste on site?: [] Yes [~ No Explain: Questions regarding this inspection? Please call us at (805) 326-3979 White - Env. Svcs. Yellow - Station Copy Pink - Business Copy · ~s'Site ~t"~pons~l,~Party Inspector: ~~ FACILITY NAME CITY OF BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES UNIFIED PROGRAM INSPECTION CHECKLIST 1715 Chester Ave., 3rd Floor, Bakersfield, CA 93301 INSPECTION DATE Section 2: Underground Storage Tanks Program [~outine [] Combined [] Joint Agency [] Multi-Agency [] Complaint Type of Tank l']tl]'~ Number of Tanks { Type of Monitoring P/.a/~ Type of Piping .Eli/I/:-~ [] Re-inspection OPERATION C V COMMENTS Proper tank data on file ~ Proper owner/operator data on file Permit tees current 1,./, Certification of Financial Responsibility Monitoring record adequate and current [,/ Maintenance records adequate and current Failure to correct prior UST violations Has there been an unauthorized release? Yes No Section 3: Aboveground Storage Tanks Program TANK SIZE(S). AGGREGATE CAPACITY Type of Tank Number of Tanks OPERATION Y N COMMENTS SPCC available SPCC on file with OES Adequate secondary protection Proper tank placarding/labeling Is tank used to dispense MVF? If yes, Does tank have overfill/overspill protection? C=Compliance ,nV=Violation Y=Yes N=NO Inspector: (,,.~ ~/?? Office of Environmental Services (805) 326-3979 White - Env. Svcs. Pink - Business Copy Business Site Responsible Party TAIT ENVIRONMENTAL SYSTEMS U.S.T. & A.S.T. MONITOR' CERTIFICATION FORM TeSting Date: 4/7/98 'Site Location: PACIFIC BELL 3221 SO. "H" STREET BAKERSFIELD County: KERN Make & Model of Monitor. System(s)! Tank ID(s):' -. 333 CLLC Code: BKFDCA14 GeD Parcel: SA-098 Site Contact: RON STANLEE Site Contact Phone #: (209) 265-9094 VEEDER-ROOT TLS-2501 Tank ID # Type of Tank: (Single Wall or Double Wall) MST or AST Contents of Tank: Capacity of Tank: Type of Product Line: (Gravity, Suction, Pressure) Type of Piping: (Single Wall or Double Wall) Tank 1 Tank 2 Tank 3 Tank 4 333 UST/DW DIESEL 4900 SUCTION DW INDICATE THE SENSORS TESTED BY PLACING A YES, NO, OR N/A & PASS OR FAIL IN CORRESPONDING BOX: Tank 1 Tank 2 Tank 3 Tank 4 Sensor Type Annular Space Sensor: Fill Sump Sensor: Piping Sump Sensor: Piping Trench Sensor: Dispenser Containment Sensor: Problems System(s) PASS N/A PASS N/A N/A N/A FOR PRESSURE TYPE SYSTEMS ONLY: Tank 1 Is Mechanical Line Leak Detector Present & Tested?: Does the Turbine Shut-Down if System Detects a Leak?: Does Positive Shut Down Occur if Monitor System is tumed off?: Tank 2 Tank 3 Tank 4 Is Tank Level Gauging System Present. Probe Type if Applicable. Type of In-Tank Leak Detection Test Performed by Monitor: Does the Monitoring System have Audible & Visual Alarms? Electronic Overfill/Level: Is the Monitoring System installed to prevent unauthorized tampering?: Is the Monitoring Devices operable as per manufacture's specifications? YES CAP 0.2 GPH YES YES 90% YES YES Date: 4/7/98 Certified Tester's ID #:545-92-3354 Technician: DON S. THOMPSON (Signature) 1100 Town & Country Road · Suite 1200 · Orange, CA92868 · (714) 560-8222 · (714) 560-8211 FAX Other Locations: San Diego, CA · Concord, CA · Sacramento, CA · Phoenix, AZ · Tucson, AZ Established 1964 Stat~ of C. alifomia (~ State Water Re. sources .~ Board CERTIFICATION OF FINANCIA _ RESPONSIBILITY FOR UNDERGROUND STORAGE TANKS CONTAINING PETROLEUM A. ! am required [o demonstraat Financial RespQnsib~i~ ia ~e required emoue' es s~ed ia ~cdoa ~?, ~ap~r l~ Div. 3, ~de ~, ~ ~ 500.~0 dollar~ ~r ~u~on~ ~ l minion dollars annual a~egate or ~D or Chief Financial Officcc Letter (attached) hereby certifies that it is in compliance with the requirements of Section 2807, (lv~ or Ttntt Oa~ o~ Operator) Art/cie 3, Chapter 18, Division 3, Title 23, California Code of Regulations. The mechanisms used to demonstrate ~nancial responsibility as required by Section 2807 are as follows: Pacific Bell Environmental Mgmt Not applicable for State' 16,850,000. Renewed ' YES 2600 Camino Ramon Alternative Mechanism Annually Room 1N200 San Ramon, CA 94583 Note: I! got/are using the State Fund as an.j/part o! your demonstratioa et !iaancial responsibil#y. ,our exe¢~ion and submission o! this cetli~cation also certgies that you are ia compliance w#l~ at/conditions tot participation in tho Fund. ~ird. P.a~ r~u,~ See Attached List F.~,~,=. PACIFIC BE~ ~.~ ~d,~ F~ N~ F~ ~ $1gaamra of Tank .~o~_Opcr ator July 12, 1998 Bakersfield City Fire Department Hazardous Materials Division 1715 Chester Ave., Suite 300 Bakersfield, CA 93301 O PACiF~C~Z~ELL A Pacific Telesis Company L. J. Uribe Environmental Associate P. O. Box 601883 Sacramento, Ca 95860-1883 Attention: Ralph Huey, Hazardous Materials Coordinator Attached is Pacific Bell's Underground Tanks Reconciliation Disclosure for the period from April 1, 1998 through June 30, 1998 If you have any questions regarding the Tank Monitoring process or the attached reports, please call Lucy Pacheco on (916) 972-4377. Thank you. Environmental Assocaite (800) 757-6575 Attachments FUEL LOGGING HAZARDOUS REIT -- NONMETERED TANKS O KERN COUNTY DEPARTMENT OF ENVIRONMENTAL MATERIALS SECTION - UNDERGROUND INVENTORY REPORT 04/01/1998 TO' 06/30/1998 HEALTH TANK page PROGRAM 04/01/1998 04/02/1998 04/03/1998 04/06/1998 04/07/1998 04/08/1998 04/09/1998 04/10/1998 04/13/1998 04/14/1998 04/15/1998 04/16/1998 04/17/1998 04/20/1998 04/21/1998 04/22/1998 04/23/1998 04/24/1998 04/27/1998 04/.28/1998 04/29/1998 04/30/1998 o5/o1/1999 05/04/1998 05/05/1998 05/06/1998 05/07/1998 05/08/1998 05/11/1998 05/12/1998 05/13/1998 05/14/1998 o5/15/1998 05/18/1998 05/19/1998 o5/2o/1999 05/21/1998 05/22/1998 o5/25/1998 05/26/1998 o5/2'7/1998 o5/28/1998 05/29/1998 06/01/1998 06/02/1998 06/03/1998 4164 4164 4163 4163 4078 4078 4078 4078 4078 4078 4078 4077 4078 4079 4079 4036 4035 4036 4035 4014 4014 4014 4016 4016 4012 4013 4012 4013 4014 4013 4014 4014 4014 4015 4014 4014 4014 3991 3991 3991 3992 3991 3993 3993 3993 3993 PROPRIETARY INFORMATION : Not for outside Pacific Bel~ except under Generator Run Generator Run Generator Run Generator Run use or disclosure written agreement 333 3221 S. H STREET BAKERSFIELD CA CAT080020514 TANK. ID : STREET : CITY/STATE: 'AGENCY ID : 'DATE 06/04/1998 o6/o5/1998 o6/o8/1998 o6/o9/1998 O6/lO/1998 o6/11/1998 06/12/1998 o6/15/1998 o6/16/1998 o6/17/1998 o6/18/1998 o6/1~/1998 o6/22/1998 o6/23/1996 o6/2~/1998 o6/26/1998 o6/26/1996 o6/29/1998 o6/3o/~998 GALLONS 3994 3995 3995 3995 3996 3996 ~3975 3975 3976 3976 3976 3978 3977 3978 3978 3979 3980 3980 3980 NON-METERED TANKS REMARKS Generator Run page PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING RE~T -- NONMETERED TANKS TANK iD : 334 STREET : 3501 COLUMBUS @ AUBURN CiTY/STATE: BAKERSFIELD CA · AGENCY ID : .CAT080020548 DATE 04/01/1998 04/02/1998 04/03/1998 04/06/1998 04/07/1998 04/08/1998 04/09/1998 04/10/1998 04/13/1998 04f14/1998 04/15/1998 04/16/1998 04/17/1998 04/20/1998 04/21/1998 04/22/1998 o4/23/1998 04/24/1998 04/27/1998 o4/28/1998 04/29/1998 o4/3o/1998 o5/ol/1998 o5/o4/1998 o5/o5/1998 o5/o6/1998 o5/o7/1998 o5/o8/1998 o5/11/1998 o5/12/1998 o5/13/1998, o5/14/1998 o5/15/1998 o5/zs/1998 o5/19/1998 o5/2o/1998 o5/21/1995 os/22/1998 o5/25/1998 o5/26/1998 o5/27/1998 o5/28/1998 o5/29/1998 o6/ol/1998 o6/o2/1998 o6/o3/1998 o6/o4/1998 o6/o5/1998 GALLONS 8O3 803 803 803 802 802 802 802 8O2 802 775 775 775 775 775 776 776 776 776 776 776 776 776 776 777 776 777 777 777 777 777 777 777 777 ,777 777 777 777 777 777 777 777 777 777 777 777 ,777 777 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under REMARKS Generator Run use or disclosure written agreement' page 3 FUEL LOGGING TANK ID : 334 STREET : 3501 COLUMBUS @ CITY/STATE: BAKERSFIELD CA AGENCY ID :'CAT080020548 -- NONMETERED TANKS AUBURN DATE GALLONS 06/08/1998 ?78 06/09/1998 777 06/t0/1998 778 06/11/1998 .778 06/12/1998 778 06/15/1998 751 06/16/1998 751 06/17/1998 751 06/18/1998 751 06/19/1998 751 06/22/1998 752 06/23/1998 752 06/24/1998 752 06/25/1998 752 06/26/1998 752 06/29/1998 752 06/30/1998 752 REMARKS Generator Run page 4 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING RE~T -- NONMETERED TANKS page 5 TANK ID : S~REET : CITY/STATE: AGENCY ID : 335 I1609 ROSEDALE HIGHWAY ROSEDALE CA CATO80020597 DATE GALLONS 04/01/1998 869 04/02/1998 868 04/03/1998 868 04/06/1998 868 04/07/1998. 853 04/08/1998 853 04/09/1998 853 04/10/1998 853 04/13/1998 853 04/14/1998 853 04/15/1998 853 04/16/1998 853 04/17/1998 853 04/20/1998 853 04/21/1998 853 04/22/1998 854 04/23/1998 839 04/24/1998 838 04/27/1998 839 04/28/1998 838 04/29/1998 839 04/30/1998 839 05/01/1998 839 05/04/1998 839 05/05/1998 839 05/06/1998 839 05/07/1998 839 05/08/1998 839 05/11/1998 839 05/12/1998 839 05/13/1998 839 05/14/1998 839 05/15/1998 839 05/18/1998 839 05/19/1998 839 05/20/1998 839 05/21/1998 839 05/22/1998 839 05/25/1998 839 05/26/1998 839 05/27/1998 840 05/28/1998 840 05/29/1998 840 06/01/1998 840 06/02/1998 840 06/03/1998 840 06/04/1998 840 06/05/1998 840 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under REMARKS Generator Run use or disclosure written agreement FUEL LOGGING R~T -- NONMETERED TANKS page 6 TANK ID : STREET : 'CITY/STATE: AGENCY ID : 335 11609 ROSEDALE ROSEDALE CA CAT080020597 HIGHWAY DATE 06/08/1998 06/09/1998 06/10/1998 06/11/1998 06/12/1998 06/15/1998 06/16/1998 06/17/1998 o6/18/1998 06/19/1998 06/22/1998 o6/23/1998 06/2.4/1998 o6/25/1998 06/26/1998 06/29/1998 06/30/1998 GALLONS 840 840 840 840 841 841 841 841 841 841 841 841 841 841 842 842 842 REMARKS PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING TANK %D, : STREET : CITY/STATE: AGENCY ID : 337 925 JEFFERSON DELANO CA CAT080020571 DATE GALLONS 04/01/1998 04/02/1998 04/03/1998 04/06/1998 04/07/1998 04/08/1998 04/09/1998 04/10/1998 04/13/1998 04/14/1998 04/15/1998 04/16/1998 04/17/1998 04/20/1998 04/21/1998 04/22/1998 04/23/1998 04/24/1998 04/27/1998 04/28/1998 04/29/1998 04/30/1998 05/01/1998 05/04/1998 05/05/1998 05/06/1998 05/07/1998 05/08/1998- 05/11/1998 05/12/1998 05/13/1998 05/14/1998 o5/15/1998 05/18/1998 05/19/1998 05/20/1998 05/21/1998 05/22/1998 05/25/1998 05/26/1998 05/27/1998 o5/28/1998 05/29/1998 06/01/1998 06/02/1998 06/03/1998 06/04/1998 06/05/1998 915 915 915 915 915 915 915 916 915 916 915 915 916 916 916 916 916 916 916 917 917 917 917 917 .917 917 917 917 917 917 917 917 917 917 917 917 917 918 918 918 918 918 918 918 918 918 918 919 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under NONMETERED TANKS REMARKS use or disclosure written agreement page FUEL LOGGING -- NONMETERED TANKS page 8 TANK ID : 337 'STREET : 925 JEFFERSON ST CITY/STATE: DELANO CA.~ AGENCY ID : CAT080020571 DATE GALLONS 06/08/1998 06/09/1998~ 06/10/1998 06/11/1998 06/12/1998 06/15/1998 06/16/1998 o6/1~/1998 06/18/1998 06/19/1998 06/22/1998 06/23/1998 06/24/1998 06/25/1998 06/26/1998 06/29/1998 06/30/~998 918 919 909 909 909 909 909 909 909 911 911 911 911 911 911 911 911 REMARKS Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING · NONMETERED TANKS page TANK ID : STREET : CITY/STATE: AGENCY ID-: 99O 11101 WHITE LANE BAKERSFIELD CA NONE DATE GALLONS REMARKS 04/01/1998 986 04/02/1998 986 04/03/1998 986 04/06/i998 986 04/07/I998 983 04/08/1998 983 04/09/1998 983 04/10/1998 984 04/13/1998 984 04/14/1998 984 04/15/1998 984 04/16/1998 984 04/17/1998 987 04/20/1998 992 04/21/1998 999 04/22/1998 1000 04/23/1998 1000 04/24/1998 1000 04/27/1998 1000 04/28/1998 1000 04/29/1998 1000 04/30/1998 1000 05/01/1998 943 05/04/1998 944 05/05/1998 945 05/06/1998 946 05/07/1998 947 05/08/1998 949 05/11/1998 949 05/12/1998 950 05/13/1998 950 05/14/1998 950 05/15/1998 950 05/18/1998 950 05/19/1998 950 05/20/1998 950 05/21/1998 950 05/22/1998 951 05/25/1998 952 05/26/1998 952 05/27/1998 953 05/28/1998 953 05/29/1998 954 06/01/1998 954 06/02/1998 954 06/03/1998 955 06/04/1998 ,956 06/05/1998 957 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under Generator Run use or disclosure written agreement FUEL LOGGING -- NONMETERED TANKS page 10 TANK ID : 990 STREET : 11101 WHITE LANE CITY/STATE: BAKERSFIELD CA AGENCY ID : NONE DATE 06/08/1998 06/09/1998 06/10/1998 06/11/1998 06/12/1998 06/15/1998 06/16/1998 06/17/1998 06/18/1998 06/19/1998 06/22/1998 06/23/1998 06/24/1998 06/25/1998 06/26/1998 06/29/1998 06/30/1998 GALLONS 958 958 958 959 959 959 959 883 '875 877 866 868 ,869 870 873 874 875 REMARKS Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING RE~T -- TANK ID : STREET : CITY/STATE: AGENCY ID : 1035 1021 CALIFORNIA ST 'OILDALE CA CAT080020449 NONMETERED TANKS DATE GALLONS REMARKS 1700 1700 1700 1700 1701 1701 1701 1701 1701 1701 1701 1701 1701 1701 1701 1701 1693 1693 1693 1693 1693 1694 1694 1695 1695 1695 1695 1695 1689 1689 1689 1689 1689 1689 1689 1686 1686 1686 1686 1687 1687 1680 1680 1680 1680 1680 1681 1681 04/01/1998 04/02/1998 04/03/1998 04/06/1998 o4/o7/1998 04/08/1998 04/09/1998 04/10/1998 04/13/1998 04/14/1998 04/15/1998 04/16/1998 04/17/1998 04/20/1998 04/21/1998 04/22/1998 04/23/1998 04/24/1998 04/27/1998 04/28/1998 04/29/1998 04/30/1998 05/01/1998 05/04/1998 05/05/1998 05/06/1998 05/07/1998 05/08/1998 05/11/1998 05/12/1998 05/13 /1998 05/14/1998 05/15/1998 05/18/1998 05/19/1998 05/20/1998 05/21/1998 05/22/1998 05/25/1998 '05/26/1998 05/27/1998 05/28/1998 05/29/1998 06/01/1998 06/02/1998 06/03/1998 06/04/1998 06/05/1998 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under Generator Run Generator Run Generator Run Generator Run Generator Run Generator Run use or disclosure written agreement page 11 FUEL LOGGING -~ NONMETERED TANKS page 12 TANK ID : 1035 STREET : 1021 CALIFORNIA ST CITY/STATE: OILDALE CA AGENCY ID : CATO80020449 DATE 06/08/1998 06/09/1998 06/10/1998 06/11/1998 06/12/1998 06/15/1998 06/16/1998 06/17/1998 06/18/1998~ 06/19/1998 06/22/1998 06/23/1998 06/24/1998 06/25/1998 06/26/1998 06/29/1998 06/30/1998 GALLONS 1681 1681 1681 1681 1681 1682 1682- 1682 1682 1683 1683 1683 1683 1684 1684 1684 i685 REMARKS PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL'LOGGING -- NONMETERED TANKS TANK 'ID : 1057" STREET : 8313 E. SEGRUE ROAD~ CITY/STATE:~L3~IONT CA AGENCY ID : CATO8002043! DATE 04/01/1998 04/02/1998 04/03/1998 04/06/1998 04/07/1998 04/08/1998 04/09/1998 04/10/1998 04/13/1998 04/14/1998 04/15/1998 04/16/1998 04/17/1998 04/20/1998 04/21/1998 04/22/1998 04/23/1998 04/24/1998 04/27/1998 04/28/1998 04/29/1998 04/30/1998 05/01/1998 .05/04/1998 05/05/1998 05/06/1998 05/07/1998 05/08/1998 05/11/1998 05/t2/1998 05/13/1998 05/14/1998 '05/15/1998 05/18/1998 05/19/1998 05/20/1998 05/21/1998 05/22/1998 05/25/1998 05/26/1998 05/27/1998 05/28/1998 05/29/1998 06/01/1998 06/02/1998 06/03/1998 06/04/1998 06/05/1998. GALLONS 848 848 848 848 848 843 843 843 843 842 842 842 843 843 843' 843 843 843 843 843 843 844 844 844 844 844 838 838 838 838 838 838 838 838 838 838 838 838 838 838 838 838 838 838 838 833 833 833 REMARKS Generator Run Generator Run Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement page 13 FUEL LOGGING RE~T -- NONMETERED TANKS page TANK ID : STREET : CITY/STATE: AGENCY ID : 1057 8313 E. SEGRUE LAMONT CA CATO80020431, ROAD DATE o6/o8/1998 o6/o9/1998 o6/~o/1998 o6/11/~996 o6/12/1998 06/15/1998 06/16/1998 06/17/1996 06/18/1998 06/19/1996 06/22/1998 06/23/1998 06/24/1998 06/25/1998 06/26/1998 06/29/1998 06/30/1998 GALLONS 833 833 833 833 833 833 '833 833 833 834 834 834 834 834 834 834 834 REMARKS PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING NONMETERED TANKS page 15 TANK ID : 1058 STREET : PAYNE & FORBES AVE CITY/STATE:' EDWARDS CA AGENCY ID : CAD981983422 DATE 04/01/1998 04/02/1998 04/03/1998 04/06/1998 04/07/1998 04/'08/1998 04/.09/1998 04/10/1998 04/13/1998 04/14/1998 04/15/1998 04/16/1998 04/17/1998 04/20/1998 04/21/1998 04/22/1998 04/23/1998 04/24/1998 04/27/1998 04/28/1998 04/29/1998 04/30/1998 05/01/1998 05/04/1998 05/05/1998 05/06/1998 05/07/1998 05/08/1998 05/11/1998 05/12/1998 05/13/1998 05/14/1998 05/15/1998 05/18/1998 05/19/1998 05/20/1998 05/21/1998 05/22/1998 05/25/1998 .05/26/1998 05/27/1998 05/28/1998 05/29/i998 06/01/1998 06/02/1998 06/03/1998 06/04/1998 06/05/1998 GALLONS 891 892 889 890 890 890 891- 890 889 888 889 889 894 893 894 895 893 892 893 894 893 893 890 890 888 888 888 888 884 882 881 882 885 886 887 887 886 889 887 885 886 886 888 889 889 888 887 887 "REMARKS Generator Run Generator Run Generator Run Generator Run Generator Run Generator Run PROPRIETARY INFORMATION : Not for use .or disclosure outside Pacific Bell except under written agreement .FUEL LOGGING - NONMETERED TANKS page 16 TANK ID :'1058 STREET : PAYNE & FORBES AVE CITY/STATE: EDWARDS CA AGENCY ID : CAD981983422 DATE GALLONS 06/08/1998 06/09/1998 06/10/1998 06/11/1998 06/12/1998 06/15/1998 06/16/1998 06/17/1998 06/18/1998 06/19/1998 06/22/1998 06/23/1998 06/24/1998 06/25/1998 06/26/1998 06/29/1998 06/30/1998 887 887 888 888 891 892 892 891 892 892 891 888 888 891 889 889 889 REMARKS Generator Run Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell-except under written agreement FUEL LOGGING -- NONMETERED TANKS TANK ID : STREET : CITY/STATE: AGENCY ID : 1139 1918 M STREET BAKERSFIELD CA CATO80020415 DATE 04/01/1998 04/02/1998 04/03/1998 04/06/1998 04/07/1998 04/08/1998 04/09/1998 04/10/1998 04/13/1998 04/14/1998 04/15/1998 04/16/1998 04/17/1998 04/20/1998 o4/21/1998 04/22/1998 04/23/1998 o4/24/1998 04/27/1998 o4/28/1998 o4/29/1998 04/30/1998 -o5/ol/1998 o5/o4/1998 05/05/1998 05/06/1998 05/07/1998 o5/o8/1998 05/11/1998 05/12/1998 05/13/1998 05/14/1998 o5/15/1998 05/18/1998 05/19/1998 05/20/1998 o5/21/1998 05/22/1998 o5/25/1998 05/26/1998 o5/27/1998 o5/28/1998 o5/29/1998 o6/ol/1998 o6/o2/1998 o6/o3/1998 o6/o4/1998 o6/o5/1998 GALLONS 16809 16809 16810 16810 16814 16814 16815 16815 16815 16815 16815 16815 16816 16817 16818 16819 16819 16820 16668 16669 16670 16671 16674 16676 16676 16676 16677 16678 16679 16680 16679 16679 16680 16680 16681 16681 16682 16684 16685 16685 16686 16686 16689 16690 16690 16691 16692 16694 REMARKS Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement page 17 FUEL LOGGING -- NONMETERED TANKS page 18 TANK ID : 1139 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA ~GENCY ID : CATO80020415 DATE GALLONS 06/08/1998 16695 06/09/1998 16696 06/10/1998 16697 06/11/1998 16697 06/12/1998 16699 06/15/1998 16701 06/16/1998 16701 06/17/1998 16702 06/18/1998 16703 06/19/!998 16706 06/22/1998 16708 06/23/1998' 167o9 06/24/1998 16711 06/25/1998 16712 06/26/1998 16715 06/29/1998 16717 06/30/1998 16718 REMARKS PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING -- NONMETERED TANKS page 19 NAME: I REALIZE THAT MISREPRESENTATIONS OF DATA ON THIS FORM MAY RESULT-IN CIVIL PENALTIES OF UP TO $25,000 PER DAY PER VIOLATION PERSUANT TO SECTION 25819 OF THE CALIFORNIA HEALTH AND SAFETY CODE. SIGNATURE: TITLE: DATE: Pacific Bell Fuel Unit 1445 Van Ness Ave, Room 236 Fresno, California 93762 PROPRIETARy INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REP~ -- NONMETERED TANKS KERN COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH HAZARDOUS MATERIALS SECTION - UNDERGROUND TANK INVENTORY'REPORT 04/01/1998 TO 06/30/1998 page PROGRAM 04/01/1998 4164 04/02/1998, 4164 04/03/1998 4163 04/06/1998 4163 04/07/1998 4078 04/08/1998 4078 04/09/1998 4078 04/10/1998 4078 04/13/1998 4078 04/14/1998 4078 04/15/1998 4078 04/16/1998 4077 04/17/1998 4078 04/20/1998 4079 04/21/1998 4079 04/22/1998 4036 04/23/1998 4035' 04/24/1998 4036 04/27/1998 4035 04/28/1998 4014 04/29/1998 4014 04/30/1998 4014 05/01/1998 4016 .05/04/1998 4016 05/05/1998 4012 05/06/1998 4013 05/07/1998 4012 05/08/1998 4013 05/11/1998 4014 05/12/1998 4013 05/13/1998 4014 05/14/1998 4014 o5/15/1998 4o14 05/18/1998 4015 05/19/1998 4014 05/20/1998 4014 05/21/1998 4014 05/22/1998 3991 05/25/1998 3991 05/26/1998 3991 05/27/1998 3992 05/28/1998 3991 05/29/1998 3993 06/01/1998 3993 06/02/1998 3993 06/03/1998 3993 PROPRIETARY INFORMATION : Not for outside Pacific Bell except Under Generator Run Generator Run Generator Run Generator Run use or disclosure written agreement' FUEL LOGGING RE T. 'NONMETERED TANKS page2 ."TANK ID :'333 STREET : 3221 S. H STREET CITY/STATE: BAKERSFIELD CA. AGENCY ID :.CATO80020514 DATE 06/04/i998 06/05/i998 06/08/1998 06/09/1998 06/10/1998 06/11/1998 06/12/1998 06/15/1998 06/16/1998 06/17/1998 06/t8/1998 06/19/.1998 06/22/1998 06/23/1998 ~06/24/1998 06/25/1998 06/26/1998 06/29/1998 06/30/1998 GALLONS 3994' 3995 3995 3995 3996 3996 3975 3975 3976 3976 3976 3978 3977 3978 3978 3979 3980~ 3980 3980 REMARKS Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING RE~T' ~r NONMETERED TANKS TANK ID : STREET : CITY/STATE: AGENCY ID : 334 3501 COLUMBUS @ AUBURN BAKERSFIELD CA CATO80020548 ·. DATE GALLONS 04/0i/1998 04/02/1998 04/03/1998 04/06/1998 04/07/1998 04/08/1998 04/09/1998 04/i0/1998 04/13/1998 04/14/1998 04/15/1998 04/16/1998 04/17/1998 04/20/1998 04/21/1998 04/22/1998 04/23/1998 04/24/1998 04/27/1998 04/28/1998 04/29/1998 04/30/1998 05/01/1998 05/04/1998 05/05/1998 05/06/1998 05/07/1998 05/08/1998 05/11/1998 05/12/1998 05/13/1998 05/14/1998 05/15/1998 05/18/1998 05/19/1998 05/20/1998 05/21/1998 05/22/1998 05/25/1998 05/26/1998 05/27/1998 05/28/1998 05/29/1998 06/01/1998 06/02/1998 06/03/1998 06/04/1998 06/05/1998 '. 803 803 803 803 802 802 802 802 802 802 775 775 775 775 775 776 776 776 776 776 776 776 776 776 777 776 777 777 777 777 777 777 777 777 777 777 777 777 777 777 777 777 777 777 777 777 777 777 . REMARKS Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement page FUEL LOGGING RE~T -- NONMETERED TANKS TANK ID : 334 STREET : 3501 COLUMBUS @ AUBURN CITY/STATE:~BAKERSFI'ELD CA .~ AGENCY ID : CAT080020548 DATE 06/08/1998 06/09/1998~ 06/10/1998 06/11/1998 06/12/1998 06/15/1998 o6/16/1998 o6/17/1998 06/18/1998 06/19/1998' 06/22/1998 06/23/1998 06/2~/1998 06/25/1998 06/26/1998 06/29/1998 06/30/1998 GALLONS 778 777 778 778 778 751 751 751 751 751 752 .752 752 752 752 752 752 REMARKS GeneratOr Run page 4 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING RE~T -- NONMETERED TANKS page 5 TANK' ID : STREET : CITY/STATE: AGENCY ID : 335 11609 ROSEDALE HIGHWAY ROSEDALE CA CAT080020597 DATE 04/01/1998 04/02/1998 04/03/1998 04/06/1998 04/07/1998 04/08/1998 04/09/1998 04/10/1998 04/13/1998 04/14/1998 .04/15/1998 04/16/1998 04/17/1998 04/20/1998 o4/21/1998 04/22/1998 04/23/1998 04/24/1998 04/27/1998 04/28/1998 04/29/1998 04/30/1998 05/01/1998 05/04/1998 05/05/1998 05/06/1998. 05/07/1998 05/08/1998 05/11/1998 05/12/1998 05/13/1998 05/14/1998 05/15/1998 05/18/1998 05/19/1998 05/20/1998 05/21/1998 05/22/1998 05/25/1998 05/26/1'998 05/27/1998 05/28/1998 05/29/1998 06/01/1998, 06/02/1998 06/03/1998 06/04/1998 06/05/1998 GALLONS 869 868 868 868 853 853 853 853 853' 853 853 853 853 853 853 854 839 838 839 838 839 839 839 839 839 839 839 839 839 839. 839 839 839 839 839 839 839 839 839 839 840 840 840 840 840 840 840 840 REMARKS GeneratOr Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING RE~T --. NONMETERED TANKS TANK ID : STREET : CITY/STATE: AGENCY ID : 335 11609 ROSEDALE'HIGHWAY ROSEDALE CA CAT080020597 DATE 06/o8/1998 06/09/1998 O6/lO/1998 06/11/1998 06/12/1998 06/15/1998 06/16/1998 06/17/1998 06/18/1998 06/19/1998 06/22/1998 06/23/1998 06/24/1998 06/25/1998 06/26/1998 06/29/1998 06/30/1998 GALLONS 840 840 840 840 841 841 841 841 841 841 841 841 841 841 842 842 842 REMARKS page PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING RE -- NONMETERED TANKs TANK ID : 33'7 STREET : 925 JEFFERSON CITY/STATE:~DELANO CA AGENCY ID : CAT080020571 ST DATE GALLONS 04/01/1998 915 04/02/1998 915 04/03/1998 915 04/06/1998 915 04/07/1998 915 04/08/1998 915 04/0~/~98 915 04/10/1998 916 04/13/1998 915 04/14/1998 916 04/15/1998 915 04/16/1998 915 04/17/1998 916 04/20/1998 916 04/21/1998 916 04/22/1998 916 04/23/1998 916 04/24/1998 916 04/27/1998 916 04/28/1998 917 04/29/1998 917 04/30/1998 917 05/01/1998 917 05/04/1998 917 05/05/1998 917 05/06/1998 917 05/07/1998 917 05/08/1998 917 05/11/1998 917 05/12/1998 917 05/13/1998 917 05/14/1998 917 05/15/1998 917 05/18/1998 917 o5/19/1998 917 05/20/1998 917 05/21/1998 917 05/22/1998 918 05/25/1998 918 05/26/1998 918 05/27/1998 918 05/28/1998 918 05/29/1998 918 06/01/1998 918 06/02/1998 918 06/03/1998 918 06/04/1998 918 06/05/1998 919 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under REMARKS use or disclosure written agreement page FUEL LOGGING TANK ID :' 337 STREET : 925 JEFFERSON CITY/STATE: DELANO CA AGENCY ID : CAT080020571 ST DATE GALLONS 06/08/1998 918 06/09/1998 919 06/10/1998 909 06/11/1998 909 06/12/1998 909 06/15/1998 909 06/16/1998 909 06/17/1998 909 06/18/1998 909 06/19/1998 911 06/22/1998 911 06/23/1998 911 06/2~/1998 911 06/25/1998 911 06/26/1998 911 06/29/1998 911 06/30/1998 911 NONMETERED TANKS REMARKS Generator Run page PROPRIETARY INFORMATION : Not for, use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING RE~T -- NONMETERED TANKS page 9 TANK ID : STREET : CITY/STATE: AGENCY ID : 990 11101 WHITE LANE BAKERSFIELD CA NONE DATE 04/01/1998 04/02/1998 04/03/1998 04/06/1998 04/07/1998 04/08/1998 04/09/1998 04/10/1998 04/13/1998 04/14/1998 o4/15/1998 04/16/1998 04/17/1998 04/20/1998 o4/21/1998 04/22/1998 04/23/1998 04/24/1998 04/27/1998 04/28/1998 o4/29/1998 o4/3o/1998 o5/ol/1998 os/o4/1998 o5/o5/1998 o5/o6/1998 o5/o7/1998 o5/o8/1998 o5/11/1998 o5/12/19,98 o5/14/1998 o5/15/1998 o5/18/1998 o5/19/1998 o5/2o/~998 o5/21/1998 o5/22/1998 o5/25/1998 o5/26/1998 o5/27/1998 o5/28/1998 o5/29/1998 o6/ol/1998 o6/o2/1998 o6/o3/1998 o6/04/1998 o6/o5/1998 GALLONS 986 986 986 986 983 983 983 984 984 984 984 984 987 992 999 1000 1000 1000 1000 1000 1000 1000 943 944 945 946 947 949 949 950 950 950 950 950 950 950 950 951 952 952 953 953 954 954 954 955 956 957 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under REMARKS Generator Run use or disclosure written agreement .FUEL LOGGING TANKID : STREET : CITY/STATE: AGENCY ID : 990 11101 WHITE BAKERSFIELD NONE DATE 06/08/1998 06/09/1998 06/10/1998 o6/11/1998 06/12/1998 o6/15/ 998 06/16/1998 06/17/1998 06/18/1998 06/19/1998 06/22/1998 06/23/1998 06/24/1998. 06/25/1998 06/26/1998 06/29/1998 06/30/1998 --NONMETERED TANKS LANE GALLONS 958' 958 958 959 959 '959 959 883 875 877 866 868 869 870 873 874 875 REMARKS Generator Run page 10 PROPRIETARy INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REP~[T -- NONMETERED TANKS page 11 TANK ID : STREET : CITY/STATE: AGENCY ID : 1035 1021 CALIFORNIA 'OILDALE CA CAT080020449 ST DATE GALLONS 04/01/1998 1700 04/02/1998 ~1700 04/03/1998 1700 04/06/1998 1700 04/07/1998 1701 04/08/1998' 1701 04/09/1998 1701 04/10/1998 1701 04/13/1998 1701 04/14/1998 1701 04/15/1998 1701 04/16/1998 1701 04/17/1998 1701 04/20/1998 1701 04/21/1998 1701 04/22/1998 1701 04/23/1998 1693 04/24/1998 1693 04/27/1998 1693 04/28/1998 1693 04/29/1998 1693 04/30/1998 1694 05/01/1998 1694 05/04/1998 1695 05/05/1998 1695. 05/06/1998 1695 05/07/1998 1695 05/08/1998' 1695 05/11/1998 1689 05/12/1998 16'89 05/13/1998 1689 05/14/1998 1689 05/15/1998 1689 05/18/1998 1689 05/19/1998 1689 05/20/1998 1686 05/21/1998 1686 0'5/22/1998 1686 05/25/1998 1686 05/26/1998 1687 05/27/1998 1687 05/28/1998 1680 05/29/1998 1680 06/01/1998 1680 06/02/1998 1680 06/03/1998 .1680 06/04/1998 168-1 06/05/1998 1681 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under REMARKS Generator Run Generator Run Generator Run Generator Run Generator Run Generator Run use or disclosure written agreement FUEL LOGGING NONMETERED TANKS page 12 TANK ID : STREET :~ CITY/STATE: AGENCY ID : 1035 1021 CALIFORNIA ST OILDALE CA CATO80020449 DATE o6/o8/1998 o6/o9/1998 06/10/1998 06/11/1998 06/12/1998 06/15/1998 06/16/1998 06/17/1998 06/18/1998 06/19/1998 06/22/1998 06/23/1998 06/24/1998 06/25/1998 06/26/1998 06/29/1998 06/30/1998 GALLONS 1681 1681 1681 1681 1681 -1682 1682 1682 1682. 1683 1683 1683 1683 1684 1684 1684 1685 REMARKS PROPRIETARY INFORMATION : Not for outside Pacific Bell except under use or disclosure written agreement FUEL LOGGING -- NONMETERED TANKS page 13 TANK ID :'1057 STREET ~ : 8313 E. SEGRUE CITY/STATE: LAMONT CA AGENCY ID : CATO80020431 ROAD DATE 04/01/1998 04/02/1998 04/03/1998 04/06/1998 04/07/1998 04/08/1998 04/09/1998 04/10/1998 04/13/1998 04/14/Z998 04/15/1998 04/16/1998 04/17/1998 04/20/1998 04/21/1998 04/22/1998 04/23/1998 04/24/1998 04/27/1998 04/28/1998 04/29/1998 04/30/1998 05/01/1998 05/04/1998 05/05/1998 05/06/1998 05/07/1998 05/08/1998 05/11/1998 05/12/1998 05/13/1998 05/14/1998 05/15/1998 05/18/1998 05/19/1998 05/20/1998 05/21/1998 05/22/1998 05/25/1998 05/26/1998 05/27/1998 05/28/1998 05/29/1998 06/01/1998 06/02/1998 06/03/1998 06/04/1998 06/05/1998 GALLONS 848 848 848 B48 848 843 843 843 843 842 842 842 843 843 843 843 843 843 843 843 843 844 844 844 844 844 838 838 838 838 838 838 838 838 838 838 838 838 838 838 838 838 838 838 838 833 833 833 REMARKS Generator Run Generator Run Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement page 14 TANK ID : STREET : CITY/STATE: AGENCY ID : 1052" 8313 E. SEGRUE LAMONT CA CATO80020431 ROAD DATE 06/08/1998 06/09/1998 06/10/1998 06/11/1998 06/12/1998 06/15/1998 06/16/1998 06/17/1998 o6/18/1998 06/19/1998 06/22/1998 06/23/1998 06/24/1998 06/25/1998 06/26/1998 06/29/1998 06/30/1998 GALLONS 833 833 833 833 833 833 833 833 833 834 834 834 834 834 834 834 834 REMARKS PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING RE~T -- NONMETERED TANKS TANK ID : STREET : CITY/STATE: AGENCY ID : 1058 PAYNE & FORBES AVE EDWARDS CA CAD981983422 DATE 04/01/1998 04/02/1998 04/03/1998 04/06/1998 04/07/1998 04/08/1998 04/09/1998 04/10/1998 04/13/1998 04/14/1998 04/15/1998 04/16/1998 04/17/1998 04/20/1998 04/21/1998 04/22/1998 04/23/1998 04/24/1998 04/27/1998 04/28/1998 04/29/1998 04/30/1998 05/01/1998 05/04/1998 05/05/1998 05/06/1998 05/07/1998. 05/08/1998 05/11/1998 05/12/1998 05/13/1998 05/14/1998 05/15/1998 05/18/1998 05/19/1998 05/20/1998 05/21/1998 05/22/1998 05/25/1998 05/26/1998 05/27/1998 05/28/1998 05/29/1998 06/01/1998 06/02/1998 06/03/1998 06/04/1998 06/05/1998 GALLONS 891 892 889 890 890 890 891 890 889 888 889 889 894 893 894 895 893 892 893 894 893 893 890 890 888 888 888 888 884 882 881 882 885 886 887 887 886 889 887 885 886 886 888 889 889 888 887 887 REMARKS Generator Run Generator Run Generator Run Generator Run Generator Run Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement page 15 FUEL LOGGING RE NONMETERED TANKS TANK ID : STREET : CITY/STATE: AGENCY ID : 1058 PAYNE & FORBES AVE EDWARDS CA CAD98!983422 DATE REMARKS GALLONS 06/08/1998 887 06/09/1998 887 06/10/1998 888 06/11/1998 888 06/12/1998 891 06/15/1998 892 06/16/1998 892 06/17/1998 891 06/18/1998 892 06/19/1998 892 06/22/1998 891 06/23/1998 888 06/24/1998 888 06/25/1998 891 06/26/1998 889 06/29/1998 889 06/30/1998 889 Generator Run Generator Run page 16 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING .- NONMETERED TANKS page 17 TANK ID : STREET : CITY/STATE: AGENCY ID : 1139 1918 M STREET BAKERSFIELD CA CATO80020415 DATE 04/01/1998 04/02/1998 04/03/1998 04/06/1998 04/07/1998 04/08/1998 04/09/1998 04/10/1998 04/13/1998 04/14/1998 04/15/1998 04/16/1998 04/17/1998 04/20/1998 04/21/1998 04/22/1998 04/23/1998 04/24/1998 04/27/1998 04/28/1998 04/29/1998 04/30/1998 05/01/1998 05/04/1998 05/05/1998, 05/06/1998 05/07/1998 05/08/1998 05/11/1998 05/12/1998 05/13/1998 05/14/1998 05/15/1998 05/18/1998 05/19/1998 05/20/1998 05/21/1998 05/22/1998 05/25/1998 05/26/1998 05/27/1998 05/28/1998 05/29/1998 06/01/1998 06/02/1998 06/03/1998 06/04/1998 06/05/1998 GALLONS 16809' 168'09 16810 16810 16814 16814 16815 16815 16815 16815 16815 16815 16816 16817 16818 16819 16819 16820 16668 16669 16670 16671 16674 16676 16676 16676 -16677 16678 16679 16680 16679 16679 16680 16680 16681 16681 16682 16684 16685 16685 16686 16686 16689 16690 16690 16691 16692 16694 REMARKS Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING RE~T -- NONMETERED TANKS TANK ID : 1139 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS 06/08/1998 16695 06/09/1998 16696 06/10/1998 16697 06/11/1998 16697 06/12/1998 16699 06/15/1998 16701 06/16/1998 16701 06/17/1998 16702 06/18/1998 16703 06/19/1998 16706 06/22/1.998 16708 06/23/1998 16709 06/24/~998 16711 06/25/1998 16712 06/26/1998 16715 06/29/1998 16717 06/30/1998 16718 REMARKS page 18 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement TANK 2051 TANK 2052 KERN COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH HAZARDOUS MATERIALS SECTION - - UNDERGROUND TANK PROGRAM INVENTORY RECONCILIATION REPORT 04/01/98 TO 06/30/98 AGENCY TANK ID: ADDRESS: CAD981630411 5650 ALDRIN COURT' BAKERSFIELD AGENCY TANK ID: · ADDRESS: CAD981630411 5650 ALDRIN COURT BAKERSFIELD FOR THE REPORTING PERIOD OF 04/01/98 TO 06/30/98, I HEREBY CERTIFY THAT DAILY INVENTORY RECONCILIATION RECORDS HAVE SHOWN VALUES WITHIN ALLOWABLE ERROR LIMITS SET BY THE WATER RESOURCES CONTROL BOARD FOR THE ABOVE TANKS. I REALIZE THAT MISREPRESENTATIONS OF DATA ON THIS FORM MAY RESULT IN CIVIL PENALTIES OF UP TO $25,000 PER DAY PER VIOLATION PERSUANT TO SECTION 25819 OF THE CALIFORNIA HEALTH AND SAFETY CODE. NAME: t~_e.~_ff_Ku n...__z ,SIGNATURE':. (~, ~,~ TITLE: Fleet Supervisor DATE: 7/21/98 Pacific Bell Fuel Unit 3707 Kings Way, Room B-18 Sacramento, California 95821 PROPRIETARY INFORMATION · Not for use or disclosure outside Pacific Bell except under written ~agreement I:'8 !:)'l D,'r-~l 4 :32 -"41~tt H F:,,', '~' ~ t~l_.l], C8 93804 NOV '26. 2002 IO.:2L ~1~ ;-;', ' :.'1 ~¥Fl ~S kEf-',[}~ ~.4._1. FUNCTIONS NOrMaL PB Bt(FDCA14,-,M-UC'"" -qO_ o 3221 SOUTH'H STREET BAKERSFIELD Ca 93304 661 882.-8370 21'12 10:21 AM T I ;£,iE.C;FL '"'~"" ~ ' ULL;-~GE = 6,3~ GALS ')0~.~: iJLLAGE= 180 GA[.S TO VOLUME = 4368 GaLS ftEIGHT ~ = 75.13 INCHES WATER VOL = 8 GALS ~dATER = 0.94 INCHES TEMP = 79.4 DEG F SYSTEM SETUP NOV 26.. 2002 10:21 SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGL I SH SYSTEM DATE.,'"T 1 ME FORMAT MON DD YYYY HH:MM:SS ×M PB BKFDCA14 SA-098 3221 SOUTH H STREET BAKERSFIELD CA 93304 · 661 832-83?8 SHIFT TIME 1 : 7:30 AM SHIFT TildE 2 : DISABLED SHIFT TIME 3 : DISABLED SHIFT TIME 4 : DISABLED TANK PER TST NEEDED I,.~N DISABLED TANK ANN TST DISABLE[) LINE RE-ENABLE METHOD PASS LINE TEST LINE PER TST NEEDED,~"-'N DISABLED LINE ANN TST NEEDED~'N DISABLED PRINT TC VOLUMES ENABLED TEMP COMPENSATION VALUE <DEG F ): 60.0 STICK HEIGHT OFFSET DISABLED H-PROTOCOL DATA FORMAT HE I GHT DAYLIGHT SAVING TIME ENABLED START DATE APR WEEK 1 SUN START TIME 2:00 AM END DATE OCT WEEK ~ SUN END TIME 2:00 aP1 RE-DI RECT LO D I SABLED EURO PROTOCOL PREFIX S PORT SETTINGS: CGdM BOARD : 1 (FXMOD) BAUD RATE : 1200 . PARITY : ODD STOP BIT : I STOP' DATA LENOTH: 7 DATA RS-232 SECURITY CODE : DIAL TYPE : TONE ANSWER ON : 1 RING MODEM SETUP STRING : DIAL TONE INTERVAL: :32 RECEIVER SETUP': D I:EMCC 19258670241 RCVR TYPE: FACSIMILE PORT NO; 1 RETRY NO: 99 RETRY DELAY: 10 CONFIRMATION REPORT,' .... ~ 2 :ALARM MON I '7145608237 RCVR TYPE: FACSIPIlLE PORT NO: 1 RETRY NO; 99 RETRY DELAY; lO CONFIRMATION REPORT: ON SYSTEM SECURITY CODE : 000000 LEAK TEST METHOD TEST CSLD : ALL TANK Pd = 95% CL I MATE FACTOR: MODERATE TST EARLY STOP :DISABLED LEAK TEST REPORT FORMAT NORMAL OUTPUT RELAY SETUP R I:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN I N-TANK ALARIdS ALL: OVERF ILL ALARM ALL:HIGH PRODUCT ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:HIGH LIQUID ALARM ALL:LOW LIQUID ALARM ALL:LIOUID WARNING ALARId HISTORY REPORT ..... S?STEtd ALARM ...... PAPER OUT AUG 27. 2002 11:25 AM PRINTER ERROR ~7, 2002 11:25 ~P1 BATTERy f~ OFF JAN 1, 1998 8:00 ~H LIE4U1D SENSOR SETUP L I:ANNULAR TRI-STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE L 2:SUMP SENSOR DUAL FLT. DISCRIMINATING CATEGORY : PIPING SUMP RECONCILIATION SETUP ....... AUTOMATIC DAILY CLOSING TildE: 2:00 AM ! PERIODIC RECONCILIATION : MODE: MONTHLY TEMP COMPENSATION STANDARD BIJS SLOT FUEL METER~'ANK TANK MAP EMPT'~ ALARM HISTORy REPORT .... IN-TANK ALARM T I:DIESEL .-~. SETUP DAT~ ~ARNING JAN 11 2001 5:19 PPI OVERFILL ALARM AP~ 9, 2002 HIGH PRODUCT ALARM APR 9.. 2002 12:47 Ptd .JAN 11, 2001 ~:21 PPI PROBE OUT APR S, 2002 12:49 PM AP~ 9, 2002 12:40 PPI JAN 11, 2001 12:~7 PM HIGH WATER WARNING JAN il, 200! 5:27 PM JAN ~1, 200! 5:22 PM DELIWERY NEEDED JUN 20, 2002 11:11 AP1 APR 9, 2002 12:49 PPI APR_.~, 2002_12:~0 PPI MAX PRODUCT ALARM APR 9, 2002 12:47 PPI AuTO DIAL TIME SETUP: D I:EMCC '". DIAL ON DATE JAN 11, 2001 DIAL TIME : DISABLED RECEIVER REPORTS: SYSTEM STATUS : PRIORITY HISTORY : IN-TANK STATUS INVENTORY' LEAK DETECT k.._~. D 2:ALARM MONITORING CO DIAL ON DATE 3AN 11. 2001 DIAL TIME : DISABLED RECEIVER REPORTS: SYSTEM STATUS : PRIORITY HISTORY : IN-TANK STATUS : INVENTORY : LEAK DETECT : RS-232 END OF MESSAGE D I SABLED AUTO DIAL ALARM SETUP D I:EMCC IN-TANK ALARMS ALL:LEAK ALARM ALL:HIGH WATER ALARM ALL:LOW PRODUCT ALARM ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED LIQUID SENSOR ALMS .~ ALL:FUEL ALARM ALL:SENSOR OUT AL~" ALL:SHORT ALARM ALL:WATER ALARM ALL:WATER OUT ALAn'1 ALL:HIGH LIQUID ALARM ALL:LOW LIQUID ALARM ALL:LIQUID WARNINC-~ D 2:ALARM MONITORING CO IN-TANK ALARMS ALL:LEAK ALARM ALL:HIGH WATER ALARM ALL:LOW PRODDCT ALARM ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED LIGUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ALL:WATER ALARM ALL:WATER OUT ALARM ALL:HIGH LIQUID ALARM ALL:LO~ LIQUID ALARM ALL:LIqUID WARNING I N-TANK SETUP T I:DIESEL pRODUCT CODE THERMAL COEFF TANK DIAMETER TANK PROFILE FULL VOL 69.0 INCH VOL 46.0 INCH VOL 23,0 INCH VOL FLOAT SIZE: WATER WARNING : HIGH WATER LIMIT: MAX OR LABEL VOL: OVERFILL LIMIT : : HIGH PRODUCT : : DELIVERY LIMIT : : ¢333 l ,000450 92.00 4 PTS 5036 4051 2518 /-'285 4.0 IN, {.5 2.0 4532 4'784 70% 3525 LOW PRODUCT : 2500 LEAD( ALARM LIMIT: 99 SUDDEN LOSS LIMIT: 99 TANK TILT : 0.00 MANIFOLDED 'rANKS T~: NONE LEAK MIN PERIODIC: 80¢;'- : 4028 LEAK MIN ANNUAL : 80~ : ]28 PERIODIC TEST TYPE STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY : ALtqF,'M HI~TO~':: REPORT ..... SENSOR ~LARt"I HIOH LIQUID ~L~H ' ~PR 9, 2002 12:35 OOT 30. 2001 I ALARM HISTORY REPOR~'-/ ..... SENSOR ALARM ..... L I:ANNULAR ANNULAR SPACE : FUEL ALARM NOV 26, 2002 i0:l? AM FUEL ALARM APR 9,. 2UE2 1'-2::35' PM FUEL ALARM OCT 30, 2001 I1:16 AM ALARM HISTORY' REPORT ..... SENSOR '"' - .... ~LA~M L 3: OTHER SENSORS ALl, DM HISTORy REPORT L 4: OTHER SENSORS