Loading...
HomeMy WebLinkAboutUST-REPORT 11/2/1998Hazardous Materials/Hazardous Waste Unified Permit . CONDITIONS OF PERMIT ON REVERSE SIDE Permit ID#:: 015-000-000894 PACIFIC BELL SA004 This oermit is issued for the followin~l: El Hazardous Materials Plan [] Underground Storage of Hazardous Materials [] Risk Management Program [] Hazardous Waste On-Site Treatment LOCATION: 1918 M ST 'IELD TANK ~'~A e.~. HAZARDOUS'S0~ ~E .'%~ CAP~J~}~ DISPENSERP~NSMONITORING Io15-ooo-ooo894-OOOl DIESEL .;;" ...... :~:':~  OFFICE OF EN~RONMENTAL SER VICES u ~. ~: ~a1715 ChesterCAAVe., 3rd Floor Approved by: ~a~ers.e~u, 93301 Office of Evim~S~ic~ Voice (661) 326-3979 F~ (661) 326-0576 Expi~tionDate: Issue Date Hazardous Materials/Hazardous Waste Unified Permit CONDITIONS OF PERMIT ON REVERSE SIDE PERMIT ID# 015-0214)00894 PACIFIC BELL LOCAi'ION 1918 M HAZARDOUS SUBSTANCE DIESEL Issued by: BAi;' CA This permit is issued for the following. Materials Plan ~round Storage of Hazardous Materials ement Program Waste T~NK .iiii:'~ANK FCS ,REM "' '~!ii::,_.....2~. :~!~%~?i;:~'h .... ?% "'"'--"%~ .,,,i~,/' .~), ~':. "~. :i~i;: ............ % !'~]]~' 'ilil,'%~h?':'ilj.?ii:,.. " --.0,. ~'"?' '"=a';~:.,:r': ,,.' ,-: ..," /.," ," .,' .? ? 2 i' .LJ~¢ Bakersfield Fire Department OFFICE OF ENVIR ONMENTAL SER VICES 1715 Chester Ave., 3rd Floor Bakersfield, CA 93301 Voice (805) 326-3979 FAX (805) 326-0576 R PIPING METHOD PRESSURE Approved by: Office of ~--a'o/fi~ental s~les Expiration Date: PIPI ONI LTT City of Bakersfield Office of Environmental Services 1715 Chester Ave., Suite 300 Bakersfield, California 93301 (805) 326-3979 An upgrade compliance certificate has been issued in connection with the operating permit for the facility indicated below. The certificate number on this facsimile matches the number on the certificate displayed at the facility. Instructions to the issuing agency: Use the space below to enter the following information in the format of your choice: name of owner; name of operator; name of facility; street address, city, and zip code of facility; facility identification number (from Form A); name of issuing agency; and date of' issue. Other identifying information may be added as deemed necessary by the local agency. This permit is issued on this 2nd day of November, 1998 to: PACIFIC BELL Permit #015-021-000894 1918 M St Bakersfield, California 93301 CONTINUED (See 2nd File) 788 ~.,.~ R T T S R C F'. 8 4 Environmental Management ? O. Box 5095. Room ] N200 San Ramon, Caiiforoia 94583-0995 April 25, 1997 City of Bakersfield Bakersfield City Fire Dept 1715 Chester Ave 3rd F1 Bakersfield, CA 93301 RE: Financial Test of Self Insurance (Underground Tanks) The attached is a copy of our Chief Financial Officer Letter to demonstrate financial responsibility for Pacific Bell's underground storage tanks. Also attached is the annual State of California Water Resources Control Board's Certification of Financial Responsibility form and a list of Pacific Bell sites that have underground storage tanks on the premises in your area of jurisdiction. Please call me on (415) 331-0924 if you have questions regarding this correspondence. Environmental Management attachment P. A. Darbee~ ~ Vice President Chief Financial Officer and Con[roller 2600 Camino Ramon, San Ramon, California 94583 (510) 823-8520 PACIFIC~:IBELL, A Pacific Telesis Company April 3, 1997 State Water Resources Control Board Division of Clean Water Programs Underground Storage Tank Cleanup Fund 2014 T Street, Suite 130 Sacramento, CA 95814 Re: Financial Test of Self-Insurance (Underground Tanks) I am the Chief Financial Officer of Pacific Bell, 2600 Camino Ramon, Room 4S001, San Ramon, California, 94583. This letter is in support of the use of the financial test of self-insurance to demonstrate financial responsibility for taking corrective action and/or compensating third parties for bodily injury and property damage caused by sudden accidental releases and/or non-sudden accidental releases in the amount of at least two million dollars annual aggregate arising from underground storage tanks. Underground storage tanks at Pacific Bell facilities are assured by this financial test or a financial test under an authorized State Program by this owner or operator. A financial test is also used by this' owner or operator to demonstrate evidence of financial responsibility in the following amounts under other EPA regulations or State programs authorized by EPA under 40 CFR Parts 271 and 145. EPA Regulations Closure (§§ 264.143 and 265.143) ..................................................................................................... Post-Closure Care (§ § 264.145 and 265.145) ...................................................................................... Liability Coverage (§§ 264.147 and 265.147) .................................................................................... Corrective Action (§§ 264.101 (b)) ................................................................................................... Plugging and Abandonment (§§ 144.63) ............................................................................................ Closure ................................................................................................................................. , ............ Post-Closure care ............................................................................................................................... Liability Coverage ............................................................................................................................. Corrective Action ............................................................................................................................... Plugging and Abandonment ............................................................................................................... Total .................................................................................................................................................. Amount $400,000. $100,000. $2,000,000. $100,000. N/A $7,400,000. $1,000,000. $2,000,000. $3,700,000. $150,000. $16,850,000. This owner or operator has not received an adverse opinion, disclaimer of opinion, or a "going concern" qualification from an independent auditor on his financial statements for the latest completed fiscal year. Alternative I (Source: Form 10K, December 31, 1996) 1. Amount of annual UST aggregate coverage being assured by a financial test, and/or guarantee ....$2,000,000 2. Amount of corrective action, closure and post-closure care costs, liability coverage, and plugging and abandonment costs covered by a financial test, and/or guarantee ................................................ $16,850,000. 3. Sum of lines 1 and 2 ................................................ ; ..................................................................... $18,850,000. 4. Total tangible assets ....................................................................................................................... $14,649,000,000. 5. Total liabilities (if any of the amount reported on line 3 is included in total liabilities, you may need to deduct that amount from this line and add that amount to line 6) ........................................... $10,722,000,000. 6. Tangible net worth (line 4 minus line 5) ......................................................................................... $3,927,000,000. 7. Is line 6 at least $ l0 million? ......................................................................................................... Yes 8. Is line 6 at least l0 times line 3? Yes 9. Have financial statements for the latest fiscal year been filed with the Securities and Exchange Commission? .................................................................................................................................... Yes 10. Have financial statements for the latest fiscal year been filed with the Energy Information Administration? ................................................................................................................................. N/A 1 I. Have financial statements for the latest fiscal year been filed with the Rural Electrician Administration? ................................................................................................................................. N/A 12. Has financial information been provided to Dun and Bradstreet and has Dun and Bradstreet provided a financial strength rating ofa 4A or 5A? (answer "yes" only if both criteria have been met) ............................................................................. Yes I hereby certify that the wording of this letter is identical to the wording specified in 40 CRF part 280.95 (d) as such regulations were constituted on the date shown immediately below. Sincerely, Peter A. Darbee Vice President, Chief Financial Officer, and Controller Pacific Bell Date: State of California State Water Resources Control Board CERTIFICATION OF FINANCIAL RESPONSIBILITY FOR UNDERGROUND STORAGE TANKS CONTAINING PETROLEUM I am required to demonstrate Financial Responsibility in the required amounts as specified in Section 2807. Chapter 18. Div. 3. Title 23. CCR: ~ $00.000 dollars per occurrence ~ 1 million dollars annual aggregate or AND or i X ]l millioa dollars per occurrence ~ '~ million dollars annual asgregate B. hereby certifies that it is in compliance with the requirements of Section 2807, (Name or Ta~ O~er or Oy, m~tor) Art/cie 3, Chapter 18, Division 3, T~tle 23, California Code of Regulations. The mechanisms used to demonstrate financial responsibility as required by Section 2807 are as follows: :: ;i Name and ~AddresS of. Issuer. :~:i.~::.::.:,' Chief Financial Pacific Bell Not Applicable For 516, 850,000 Renewed Yes Yes Officer Letter Environmental Mgmt State Alternative (Attached) PO Box 5095, RM 1NZ00 Mechanism Annually San Ramon, CA 949583-0995 Note: If you are using the State Fund as any part of your demonstration of financial responsibility, of this certification also certifies that you are in compliance w/th all conditions for participation in the Fund. ~our execution and submission D. Fa~lity Name Fa, il;ty Name Fa~Ii~.' Name Facility Nam e Faeility Name Pacific Bell See Attached List Fa,illty Address Fa~lity Address Fa~lity.a~ldress Fa~lity Address /4~//~4 7 Nancy Clancy/Environmental Advisor Dab / Name of~Wimes~ or No~r~ ~ - ~ ~ Co~ - Fa~i~s) Mar, 2? 16:02 1997 tank-aOdr-c~lc-geopar-county-gal-proouct-oevice Page 7 314 832 L STREET FTUNCA11 HUMBOLDT ~ FO~, CA 315 S.S MI N/E GARBERVILLE GRVLCAIB TE020 HUMBOLDT GARBERVILLE, CA 317 4 MILES S/O SCOTIA SCOTCR1A ?E033 HUMBOLDT SCOTIA, CR 1000 DIESELI (250 0 2000 DIESEL1 (250I) JO0 2000 DIESEL1 (250I) 320 301E STREET BRWLCA11 DA103 IMPERIRL BRAWLEY, CR 1500 DIESEL1 (250) TRUS 592 1029 2ND STREET ELCNCRSO 0R618 IMPERIAL 8000 UNLEADED EL CENTRO, CA 593 1029 2ND STREET ELCNCR$O 0A618 IMPERIRL 8000 DIESEL2 EL CENTRO, CA (350) REPL [3SO) REAL 1540 763 STATE ST ELCNCA01 0A122 IMPERIAL EL CENTRO, CA 4013 DIESEL1 (350)RPLCD 333 3221 S. H STREET BKFDCRX4 SA098 KERN BAKERSFIELD, CA 334 3501 COLUMBUS ~ AUBURN BKFDCA13 SAl14 KERN BAKERSFIELD, CA 5000 DIESEL1 1000 DIESEL1 (250I) JO0 (250I) JO0 Mar 27 16:02 1997 tank*addr-ciic-geopar-county-gal-product-device Page 8 990 11101 WHITE LRNE BKFDCA19 SA532 KERN BAKERSFIELD, CA 1139 1918 M STREET BKFDCA12 SRO04 KERN BAKERSFIELD, CA 2051 5650 ALORIN CT BKFDCA53 SR703 KERN BAKERSFIELD, CA 2052 5650 ALORIN CT BKFOCAS3 5fl703 KERN BAKERSFIELD, CA 1000 DIESEL1 20149 DIESEL1 5076 DIESEL2 12032 UNLEflOED (250I) TRW (350)RPLCD (3SO)RPLCG (350)RPLCG 337 925 JEFFERSON ST OELNCRll SA149 KERN DELANO, CA 1000 DIESEL1 (250I) JO0 1057 8313 E. 5EGRUE ROAO LAHTCR11 SAOIO KERN LAMONT, CA 1000 DIESEL1 (250I)REPL 1035 1021 CALIFORNIA ST OLOLCAll SROI3 kERN OILDALE, CA 2000 DIESEL2 (2SOI+) RE 335 11609 ROSEORLE HIGHWAY BKFDCRI? SA224 KERN ROSEDALE, Ca 1000 DIESELI (250I) JO0 204 11091 AVENUE 10 1/2 HNFRCA50 SDRO0 KINGS 10000 UNLEADED (250) HANFORD, CA PACIFIC~:~BELL ~ A Pacific Telesis Company C. S. Nantze Environmental/Site Manager P. O. Box 601883 Sacramento, Ca 95860-1883 April 14, 1997 Bakersfield City Fire Department Hazardous Materials Division 17.15 Chester Ave., Suite 300 Bakersfield, CA 93301 Attention' Ralph Huey, Hazardous Materials Coordinator Attached is Pacific Bell's Underground Tanks Reconciliation Disclosure for the period from January 1, 1997 through March 31, 1997. If you have any questions regarding the Tank Monitoring process or the attached reports, please call Donna Hoover on (916) 972-4379 or Veda Bautista on (916) 972-4377. Thank you. ,,~)~t,) C. S. Nantze Environmental/Site Manager (800) 757-6575 CSN:Iu Attachments FUEL LOGGING -- NONMETERED TANKS page 18 TANK ID : : ~STATE: AGENCY ID : 1139 1918 M STREET BAKERSFIELD CA CATO80020415 DATE GALLONS REMARKS 01/01/1997 17655 01/02/1997 17655 01/03/1997 17653 01/06/1997 17650 01/07/1997 17649 01/08/1997 17648 01/09/1997 17648 01/10/1997 17647 01/13/1997 17644 01/14/1997 17643 01/15/1997 17641 01/16/1997 17640 01/17/1997 17639 01/20/1997 17637 01/21/1997 17636 01/22/1997 17636 01/23/1997 17635 01/24/1997 17635 01/27/1997 17632 01/28/1997 17632 01/29/1997 17631 01/30/1997 17631 01/31/1997 17631 02/03/1997 17630 02/04/1997 17630 02/05/1997 17629 02/06/1997 17629 02/07/1997 17629 02/10/1997 17628 02/11/1997 17627 02/12/1997 17627 02/13/1997 17626 02/14/1997 17626 02/17/1997 17626 02/18/1997 17625 02/19/1997 17625 02/20/1997 17624 02/21/1997 17624 02/24/1997 17624 02/25/1997 17625 02/26/1997 17625 02/27/1997 17625 02/28/1997 17624 03/03/1997 17623 03/04/1997 17623 03/05/1997 17623 03/06/1997 17624 03/07/!997 17624 PROPRIETARY INFORMATION : Not for Pacific Bell except under use or disclosure written agreement FUEL LOGGING REPOT -- NONMETERED TANKS page 19 TANK ID : 1139 : 1918 M STREET /STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS 03/10f1997 03/11f1997 03/12~1997 03/13~1997 03/14~1997 03/17~1997 03/18~1997 03/19,~1997 03/20/1997 03/21/1997 03/24/1997 03/25/1997 03/26/1997 03/27/1997 03/28/1997 03/31/1997 17625 17625 17626 17626 17627 17628 17628 17629 17630 17631 17633 17634 17635 17636 17637 17638 REMARKS PROPRIETARY INFORMATION : Not for use or disclosure tside Pacific Bell except under written agreement A~ ESOP Co~A~ ROBERT.H. LEE & ASSOCIATES, INC. ARCHITECTURE PLANNING ENVIRONMENTAL SERVICES !137 NOR~ McDow~t~ Brvo., P~rA~tr~A, CA 94954-1110 lVinmmo A~Da~Sa: P.O. Box 750908 P~rALmo,, CA 94975 PHO~'~ 707-76:5-1660 FAX 70%765-9908 VOICE MAtt 707-765-2344 JOHN W. JOHNSON Architect Co*PreaJdem Architec~ Co-Presidem JOHN B. HIC3~S Architm Vic~ Prefdent CECIL R. SPENCER Architect Vic~ President JAMES H. RAY Civil EnaJne~ BRUCE J. GREENFIELD Architect Associate HOWARD G. KIMURA Associate JAME$ K. PRF, STF. N Associate GARY M. SF. JVILING Architect Associate BLYTHE R. WILSON Architect Asso~ate December 30, 1996 Bakersfield Fire Department' Ralph Huey 2130 G Street Bakersfield, CA 93301 JIIN £ 1997 RE: UNDERGROUND STORAGE TANK WRITTEN MONITORING PLANS Dear Ralph Huey: Enclosed are the Underground Storage Tank Monitoring Plan(s) and related documents for the Pacific Bell facilities as listed on the attached sheet. If there are any further correspondences related to these submissions, please direct them to: Pacific Bell Nancy Clancy 2600 Camino Ramon, Room 1N200 San Ramon, CA 94583 Sincerely, ROBERT H. LEE & ASSOCIATES, INC. Steven A. Skanderson Project Manager Enclosure cc: Nancy Clancy - Pacific Bell File ~*~ ~x'rA, GA SActoa~ro, CA B£LLEVUE, WA LA HAagA, CA Sco~rsD~a.~, AZ SAO04 PACIFIC BELL 1918 M STREET BAKERSFIELDw CA 93301 Pacific Bell Underground Storage Tank(s) Written Monitoring Procedures and Emergency Response Plan 1997 Pacific Bell - SA004 (Facility Name and ID) 1918 M STREET (Facility Address) BAKERSFIELD (Facility City) KERN (Facility County) Certification I hereby certify that all monitoring and maintenance of the UST(s) and equipment will be conducted as required by Article 5, Title 23, CCR. To the best of my knowledge, under penalty of perjury, that the information contained in this Underground Storage Tank Monitoring Plan is true and correct. I understand that I may be required to show proof of compliance during any facility inspection conducted by local, County, State or Federal authorities. ~,~d~// Nan c y C 1 an c y Authorized/Signature / Print Name / .~/~d~//-~' Environmental Management Date Title Facility Information Date: December 14, 1996 Facility Name: Pacific Bell (SA004) Street Address: 1918 M STREET Business Type: Telecommunication EPA ID#: CATO80020415 Mailing Address: P.O. Box 5095, Room 1N200 Billing Address: P.O. Box 601883 Shift 1 Employees:9 Shift 2 Employees: Shift 1 Start: Shift 2 Start: Shift 1 End: Shift 2 End: Facility ID: $A004 City: BAKERSFIELD D & B#: 10-340-1618 Uniform Building Code Class: B1 City: San Ramon City: Sacramento Zip:93301 SIC Code: 4811 Zip: 94583-0995 Zip: 95860-1883 Shift 3 Employees: Shift 3 Start: Shift 3 End: Primary Contact: Title: Secondary Contact: Executive Contact: Title: HMMP Contact: Title: Property Owner: Mailing Address: City: BILL KEENAN Site Manager Emergency Control Center 24 hours/day Nancy Clancy . Corporate Environmenta Management Robert H. Lee & Associates. Inc Mr. Steven A. Skanderson Environmental Manager Pacific Bell P.O. Box 5095, Room 1N200 San Ramon, CA Phone Number: 510-823-4401 Phone Number: 916-977-7777 Phone Number: 415-331-0924 Phone Number: 800-765-1025 Phone Number: 415-331-0924 Zip: 94583-0995 Adlacent Properties Direction North: South: East: West Business Name Contact Phone Special Land Uses (within) 1 mile) Direction Business Name Contact Phone EWater Table .(fO.:UNKNOWN Flood Zone:unknown arthquake Faults:None within 1 mile pg. 1 Emergency Response Plan Facility Name: Pacific Bell Date: December 14, 1996 Facility ID:SA004 All Personnel Internal Notification: Yes Offsite Notification: N/A ER Plan Location: Yes Evac. Procedures: Yes Spill Procedures: Yes Chemical Handlers Hand/Store Method: Yes PPE: Yes Spill/Fire Equip: Yes Exposure Hazards: Yes Emergency Response Team Rescue: No Shutdown: Yes ER Equip. Maint: Yes ER Procedures: Yes Annual Retrain: Yes Emergency Response Documents Verify training Yes Desc. training: Yes 3 year archived Yes Drill documentation Yes Evacuation Notification Shouting: Yes Horns: Yes Alarms: Yes P A Systems: Yes Telephones: Yes Evacuation Procedures Assembly Area: Yes Maps: Yes Re-entry: Yes Emergency Contacts Emergency: Fire/Police/Ambulance: State Agency: Other Agency Name: Other Agency Phone: 916-977-7777 911 800-852-7550 Bakersfield Fire Department 805-326-3979 Nearest Medical Facility: dial 911 for local assistance Name: Address: City: Phone: Other Evacuation Planning Information Emergency Response: Pacific Bell Emergency Control Center: 916-977-7777 (24 hrs. a day) Abnormal, hazardous and emergency conditions which may effect service, company building and/or adverse publicity should be reported to the Emergency Control Center. This organization maintains the names, home addresses and phone numbers (office and home) of contact persons who are qualified and authorized to assist federal, state and local emergency response personnel in the event of an emergency. The center is manned on a 24-hour per day, 7-day per week basis. pg. 2 Emergency Response Plan Facility Name: Pacific Bell Date: December 14, 1996 Facility ID:SA004 Equipment Location: Engine Room Responsible Inspector: Power Supervisor Personal Protection Equipment First-Aid Kits Eye Wash stations Gloves Hard Hats Safety Glasses Spill Control Equipment Brooms Fire Extinguishers Neutralizers Location: 1 of 2 Inspection Frequency: Monthly Communication Devices Telephones Verbal Pa System Alarms Pagers Equipment Location: Responsible Inspector: Sacramento Fuel Unit Location: 2 of 2 Inspection Frequency: Daily Personal Protection Equipment Spill Control Equipment TLS-350 Communication Devices pg. 3 Tank Monitoring Equipment Facility Name: Pacific Bell Date: December 14, 1996 Facility ID: SA004 Inventory control monitoring of the fuel and long term tank monitoring for product leakage is accomplished with in-tank continuous product monitoring provided through the installation of the TLS-350 Tank Level Sensor manufactured by Veeder-Root. The TLS-350 consists of a Computerized Inventory Monitor (CIM) and one Digital Sending Probe (DSP) for each tank being monitored. The highly accurate, all electronic probe has no moving parts for greater accuracy and less maintenance than other electro-mechanical, float-type devices. A single CIM can handle multiple probes and continuously monitor each one, analyzing their signals for liquid, temperature, depth and water level. Based on this input, the CIM computes volumes and stores this information for remote polling. The RE-232C Serial Interface Communication port permits access to TLS-350 information from remote locations via telephone lines. This serial interface is capable of handling up to 16 polling stations from centralized remote locations. The output of the serial port can be formatted for teletype or computer (IBM-PC) interface. The TLS System has four modes of operation - Leak Detection, Tank Detection, Interstitial/Piping Sump Lead Detection and Automatic Delivery Reporting. When the leak monitor mode is activated, the TLS System continuously monitors fuel levels in each tank and can detect losses of 0.2 gph. An hourly report on each tank shows temperature-compensated inventory changes to 0.1 gallon based on inventories when the tank leak mode is initiated. The Leak Monitor is activated through a push-button mounted on the front panel, or remotely through the RS-232 Telecommunications Interface. The Tank Inventory Report presents the current status of each tank. It provides station location, date and time, volume and level of fuel, water level and temperature. Interstitial/Piping Sump Leak monitoring will be provided using two liquid sensors placed in the double wall tank annular space and in the tank manhole space. The LED display on the TLS console will flash indicating the alarm cause and location. The Automatic Delivery Increase Report features are generated two minutes after fuel is delivered to the tank. The printout includes date, time, volume and temperature before and after the increase and the net increase of inventory. Pacific Bell's UST/IS database system automatically calls the TLS monitoring system and "reads" alarms and tank data four times per day. The alarms are investigated by our personnel in the centralized Fuel Administration Center located in Sacramento, California. In the event the on site TLS device panel indicates an alarm condition the Power Room/Fleet personnel are instructed via an "In Case of Alarm" Notice posted on the device panel to contact the following: Power Room Supervisor, Site Manager, Real Estate Facility Engineer, Fuel Administrator Center. All equipment used in implementing the monitoring program shall be installed, calibrated, operated and maintained in accordance with the manufacturer's instructions, including routine maintenance and service checks. The system is inspected once per calendar year by a third party in accordance with Article 5, Title 23, CCR. Copies of the recertification report shall be sent to the administering agency and copies will be maintained on site. pg. 4 Emergency Response Plan Facility Name: Pacific Bell Date: December 14, 1996 Facility ID: SA004 Separation of Materials This facility does not store material by type of quantity which requires special separation consideration. The facility was designed to prevent fire or explosion in accordance with applicable National Fire Prevention Association Guidelines and local fire codes. The material of construction is compatible with the product stored. The tank(s) is secured to prevent unauthorized inputs or withdrawals. Monitoring Program - Fuel Storage Tanks The monitoring program consists of an "initial" precision leak test using the Horner "Ezy-Chek" technique (or equivalent) followed by in-tank product monitoring. Recordkeeping Recordkeeping is accomplished by a mechanized database that automatically polls the in-tank monitor daily. Records will be made available to any agency of jurisdiction within 24 hours via fax. Requests for data should be called to Pacific Bell's Sacramento Fuel Unit on 916-972-4377. All recordable leaks and spills will be recorded on a Hazardous Material Incident Report, Form Number FR-0023. Emergency Equipment A number of fire extinguishers are kept on the premises at all times. They are placed at strategic locations throughout the facility in accordance with the protection requirements of NFPA 10. Additional emergency equipment will be obtained as needed form Pacific Bell contracted hazardous material and hazardous waste handling vendors. The fire extinguishers are maintained and serviced by a professional outside contractor on a yearly basis. A visual inspection is made by the facility wardens on a regular basis to ensure the adequacy of the emergency equipment. Contingency Plan Unauthorized releases (leaks and spills) of petroleum products will be recorded utilizing the Hazardous Materials Incident Report Form Number FR-0023 and reported by the operator of the underground storage tank immediately to the following: 1) Bakersfield Fire Department, 805-326-3979 2) Office of Emergency Services 800-852-7550 3) National Response Center 800-424-8802 4) Pacific Bell Emergency Control Center 916-977-7777 5) Environmental Management (415) 331-0924 6) Real Estate Department Reports Center 800-953-1006 7) Respective upper management within group. pg. 5 Emergency Response Plan (cont.) Facility Name: Pacific Bell Date: December 14, 1996 Facility ID: SA004 In case of fires, the local Fire Department and Pacific Bell Emergency Control Center will be notified promptly by the operator of the underground tank. In each step of notification, documentation will be prepared to include: 1) Location 2) Specific description and location of the area involved 3) Time and date of occurrence 4) Description of spill and type of material 5) Approximate quantity of material that spilled/leaked All recordable leak and spill records will be maintained on the site. The key personnel on the site (Building Warden and Site Manager) are trained for responding appropriately to any major catastrophe. A training program conducted by the training department of Pacific Bell provides the information to the key personnel regarding emergency telephone numbers, reporting requirements, location of emergency equipment and evacuation procedures. This information is true and correct. If there is any change which would materially effect the Hazardous Material Management Plan, we will amend the appropriate sections. pg. 6 Tank Construction Facility Name: Pacific Bell Date: December 14, 1996 Facility ID: SA004 Tank Number:2051 Tank Number:0 Tank Number:0 Tank Capacity:20000 Tank Capacity:0 Tank Capacity:0 Fuel:DIESEL2 Fuel: Fuel: WalI:DW Wall: Wall: Installation: 1996 Installation:0 Installation:0 Tank Manufacturer:MODERN WLD Tank Manufacturer: Tank Manufacturer: Tank Material:COMP Tank Material: Tank Material: Tank Number:0 Tank Number:0 Tank Number:0 Tank Capacity:0 Tank Capacity:0 Tank Capacity:0 Fuel: Fuel: Fuel: Wall: Wall: Wall: Installation:0 Installation:0 Installation:0 Tank Manufacturer: Tank Manufacturer: Tank Manufacturer: Tank Material: Tank Material: Tank Material: Piping Construction: DW-ENVIROFLEX Piping Material: EF Piping Type: SUCTION pg. 7 Date: December 14 }96 WRITTEN MONITORING PROCEDURES UNDERGROUND STORAGE TANK MONITORING PROGRAM This monitoring program must be kept at the UST location at all times. The information on this monitoring program are conditions of the operating permit. The permit holder must notify Bakersfield Fire Department within 30 days of any changes to the monitoring procedures, unless required to obtain approval before making the change. Required by Sections 2632(d) and 2641(h) GER. Facility Name PACIFIC BELL (SA004) Facility Address 1918 M STREET, BAKERSFIELD Describe the frequency of performing the monitoring: Tank: Continuous Piping: CONTINUOUS What methods and equipment, identified by name and model, will be used for performing the monitoring: Tank: Veeder Root TLS-350 Piping: Veeder Root TLS-350 Describe the location(s) where the monitoring will be performed (facility plot plan should be attached): The monitoring will be performed at the site - the TLS-350 alarm panel is located in the ENGINE/POWER ROOM and also monitored remotely by the Sacramento Fuel Unit. List the name(s) and title(s) of the people responsible for performing the monitoring and/or maintaining the equipment. Sacramento Fuel Unit: 916-972-4377 Reporting Format for monitoring: Inventory control monitoring of the fuel and long term tank monitoring for product leakage is accomplished with in-tank continuous product monitoring provided through the installation of the TLS-350 Tank Level Sensor manufactured by Veeder-Root. The TLS-350 consists of a Computerized Inventory Monitor (CIM) and one Digital Sending Probe (DSP) for each tank being monitored. The highly accurate, all electronic probe has no moving parts for greater accuracy and less maintenance than other electro- mechanical, float-type devices. A single CIM can handle multiple probes and continuously monitor each one, analyzing their signals for liquid, temperature, depth and water level. Based on this input, the CIM computes volumes and stores this information for remote polling. The RE-232C Serial Interface Communication port permits access to TLS-350 information from remote locations via telephone lines. This serial interface is capable of handling up to 16 polling stations from centralized remote locations. The output of the serial port can be formatted for teletype or computer (IBM-PC) interface. pg. 8 F. Reporting Form~or monitoring: (cont.) The TLS System has four modes of operation - Leak Detection, Tank Detection, Interstitial/Piping Sump Lead Detection and Automatic Delivery Reporting. When the leak monitor mode is activated, the TLS System continuously monitors fuel levels in each tank and can detect losses of 0.2 gph. An hourly report on each tank shows temperature- compensated inventory changes to 0.1 gallon based on inventories when the tank leak mode is initiated. The Leak Monitor is activated through a push-button mounted on the front panel, or remotely through the RS-232 Telecommunications Interface. The Tank Inventory Report presents the current status of each tank. It provides station location, date and time, volume and level of fuel, water level and temperature. Interstitial/Piping Sump Leak monitoring will be provided using two liquid sensors placed in the double wall tank annular space and in the tank manhole space. The LED display on the TLS console will flash indicating the alarm cause and location. The Automatic Delivery Increase Report features are generated two minutes after fuel is delivered to the tank. The printout includes date, time, volume and temperature before and after the increase and the net increase of inventory. Describe the preventative maintenance schedule for the monitoring equipment. Note: Maintenance must be in accordance with the manufacturers' maintenance schedule but not less than every 12 months. All equipment used in implementing the monitoring program shall be installed, calibrated, operated and maintained in accordance with the manufacturer's instructions, including routine maintenance and service checks. The system is inspected once per calendar year by a third party in accordance with Article 5, Title 23, CCR. Copies of the recertification report shall be sent to the administering agency and copies will be maintained on site. Describe the training necessary for the operation of UST system, including piping, and the monitoring equipment: The key personnel on the site are trained for responding appropriately to any major catastrophe. A training program conducted by the training department of Pacific Bell provides the information to the key personnel regarding emergency telephone numbers, reporting requirements, location of emergency equipment and evacuation procedures. All personnel involved with maintaining the monitoring system have been trained and certified by the manufacturer of the equipment in accordance with Article 5, Title 23, CCR. pg. 9 Date~ EMERGENCY RESPONSE PLAN UNDERGROUND STORAGE TANK MONITORING PROGRAM This monitoring program must be kept at the UST location at all times. The information on this monitoring program are conditions of the operating permit. The permit holder must notify Bakersfield Fire Department within 30 days of any changes to the monitoring procedures, unless required to obtain approval before making the change. Required by Sections 2632(d) and 2641(h) CCR. Facility Name Pacific Bell (SA004) Facility Address 1918 M STREET, BAKERSFIELD e o o e If an unauthorized release occurs, how will the hazardous substance be cleaned up? Note: If released hazardous substances reaches the environment, increase the fire or explosion hazard, are not cleaned up from the secondary containment within 8 hours, or deteriorate the secondary containment, then Bakersfield Fire Department must be notified within 24 hours. If an unauthorized release occurs contact the authorized person(s) listed below in//5. They will make arrangements with Pacific Bell approved contractor for clean-up. Describe the proposed methods and equipment to be used for removing and properly disposing of any hazardous substances. Immediate Action: a. Notify a responsible manager. Determine nature, location, magnitude and severity of incident. b. Move people away from the area as appropriate. c. Contain by arranging physical barriers (i.e. dikes, berms, etc.) Use of sorbents (i.e., neutralizers, oil absorbent material, rags, etc.) d. If there has been a release into the annular space of the tank, Pacific Bell will immediately order one of their contractors and an approved Hazardous Material/Waste Disposition vendor to the site where removal and cleaning of the annular space would be completed. Testing and replacing of the alarm sensors will be performed as required. Describe the location and availability of the required cleanup equipment in item 2 above. Spill Control Equipment is located in the ENGINE/POWER ROOM Describe the maintenance schedule for the cleanup equipment. Cleanup equipment is inspected monthly by the Power Supervisor. List the name(s) and title(s) of the person(s) responsible for authorizing any work necessary under the response plan: BILL KEENAN / SITE MANAGER / 510-823-4401 Emergency Control Center on 916-977-7777 (24 hours a day). Environmental Management Hotline on 510-823-9833 (8am - 5pm). pg. 10 PACIFIC ~ BELL BU3INESS NA,M~ PACIfiC BELL BKFDCA12 SAO04 SITE MAP BU$IN]~SADDP,~S. 1918 M STREET BAKERSFIELD DATE 3/22/96 ZIP CODE DP, AW]NC, SCALE NOT TO SCALE SYMBOL LEGEND M ELEC~ICAL PANEL SHUT-OFF NA]tJRAL OAS SHUT-OFF WATER SHUT-OFF EMERGENCY PUMP SHUT-OFF TANK MONITORING ALARM ]]~].EPHONE FIRST ND KIT FIRE EXTINGUISHER STORM DRAIN SANITARY SEWER STAGING ARE~ EVACUATI ON / HMMP, AND MS~S LOCATION FIRE HYDRANT FENCE EMERGENCY RESPONSE EQUIPMENT/ABSORBENTS ABOVEGROUND STORAGE TANK I~-~! UNDERGROUND STORAGE TANK MOTOR OILS & LUBRICANTS (COMBUSTIBLE U(~IIDS) BATTERY ELECTROLY'IE (C~ROS~V[ UQU~D) GASOENE (FLAMMABLE UQUIDS) DIESEL FUEL (COMBUS~BLE UQU~DS) NITROGEN (COMPRESSED GAS) PROPANE (FLAMMABLE lIQUID) ACE3YI.ENE (COMPRESSED GAS) ANTIFREEZE/COOLANTS WASTE OIL (FLAMMAaLE UaU~D) FIRE PULL BOX BAKERSFIELD FIRE DEPARTMENT January 6,1997 FIRE CHIEF MICHAEL R. KELLY ADMINI~lVE ~ERVlCES 2101 'H" Street Bakersfield, CA 93,301 (805) 326-3941 FAX (805) 395-1349 SUPPRESSION SSRVICF.~ 2101 "H' SlTeet Bakersfield, CA 93301 (805) 326-3941 FAX (805) 395-1349 PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 (805) 326-3951 FAX (805) 326-0576 ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 (805) 326-3979 FAX (805) 326-0676 TRAINING DIVISION 5642 Victor Street Bakersfield, CA 93308 (805) 399-4697 FAX (805) 399-5763 Irene Soto Pacific Bell 2600 Camino Ramon, 1N-200 San Ramon, CA 94583 CLOSURE OF 1 UNDERGROUND HAZARDOUS SUBSTANCE STORAGE TANK LOCATED AT 1918 "M" STREET IN BAKERSFIELD. PERMIT #BR-0147. Dear Ms. Soto: This is to inform you that this department has reviewed the results for the preliminary assessment associated with the closure of the tank located at the above stated address. Based upon laboratory data submitted, this office is satisfied with the assessment performed and requires no further action at this time. If you have any questions regarding this matter, please contact me at (805) 326-3979. Sincerely, Howard H. Wines, III Hazardous Materials Technician HHW/dlm CC: Kathy Gill, RWQCB Richard Johnson, Pacific Bell Walter Gage, IT Corp. Regional Office INTERNATIONAL TECHNOLOGY CORPORATION 2055 Junction Avenue San Jose, California 95131-2105 408-894-1200 Fax: 408-894-0701 December 20, 1996 IT Project No. 765900 Mr. Mark Turk Bakersfield Fire Department 1715 Chester Street Bakersfield, CA 93301 Subject: Tank Removal Final Report Pacific Bell Facility 1918 M Street Bakersfield, California Dear Mr. Wines: /; On behalf of Pacific Bell, IT Corporation is pleased to transmit this final report on underground storage tank replacement activities at the above referenced site. If you have any questions, please call me at (408) 894-1200. Sincerely, IT CORPORATION Walter Gage Project Geologist CC.' Nancy Clancy, Pacific Bell Richard Johnson, Pacific Bell 624 A..G CONTRACT ENVIRONMENTAL SERVICE C£1v Ao58 , N. MILLS AVE., STE. 107 CLAREMONT, CA 91711 J~///~' OIJ,<. (800) 554-3458 TEST CERTWICATE CUSTOMER: PAC BELL PHONE: 800-329-8465 ADDRESS: 1918 M STREET CITY: BAKERSFIELD STATE: CA ZIP: LOCATION ADDRESS: SAME PHONE: CITY: STATE: ZIP: TEST REQUESTED BY: YON REGLI - A. E. SCHMIDT DATE: 8-26-96 ITEM OR SYSTEM TESTED TANK IDS CAPACITY TANK TEST TANK TEST LINE TEST LINE TEST LEAK RESULTS- GAL/H RESULTS- ~AL/H DETECTOR P/F P/F P/F ~I-DIESEL 20,000 GAL PASS +.0176 PASS 0.0 N/A REMARKS: TYPE OF TANK TEST~ US TEST 2000 U/P TYPE OF LINES~ SUCTION THIS IS TO CERTIFY THAT THE ABOVE TANK(S) AND ASSOCIATED PIPING SYSTEM(S) ARE "TIGHT" AND MEET THE CRITERIA ESTABLISHED BY THE NFPA PAMPHLET 329. OPERATOR ANTONIO DO~EZ 1[ CERTIFICATION DATE II, 8-26-96 LICENSE #0-1571 C~NTRACT ENVIRONMENTAL SERVICE ANTONIO DOMINGUF_.Z U~dergrou~d Tad Tester 2058 N. MILLS AVENUE, SUITE 107 CLAREMONT, CA 91711 (909) 44~-1266 OR (800) $$4-3458 Fax: {909) 445-1269 CO.CT ENVIRONMENTAL ~058 N. MILLS AVE., STE. CLAREMONT, CA 91711 909-445-1266 S VICE A CURITE LINE ~ST DA TA SHEET CUSTOMER LOCATION PAC BELL 1918 M STREET BAKERSFIELD DATE 8-26-96 TANK 1 TANK 2 TANK 3 TANK 4 CONTENTS DIESEL PUMP MANUFACTURER MARLEY ISOLATION MECHANISM 40 SCREW TEST PRESSURE 50 PSI INITIAL CYLINDER LEVEL 0550 FINAL CYLINDER LEVEL 0550 LEAK RATE= (ICL-FCL) X2 0.0 TIME STARTED 1020 TIME COMPLETED 1050 TOTAL TEST TIME 30 MIN. LINE LEAK DETECTOR TEST DA TA SHEET SERIAL NUMBER RESILIENCY OPENING TIME TEST LEAK RATE ML/MIN HOLDING PSI METERING PSI CONCLUSION (PASS/FAIL) N/A REMARKS: TYPE OF LINES: NON - PRESSURIZED TECHNICIAN: ~~ ~-- DATE: ANTONIO DOMIN~Z 8-26-96 ,7~R ~TTM'R~ ~ ~Tm¥. PAC R~.T,T, VON R~T,T 1 c)1 R M :al R : 1 HVC)T, / r]V ( ~AT, / TA~ '~ t17 qT_~q q~ ,~. AT, T~'R Aq"TC)N 'R~D ~6.q531! QN~PART~ CA. q1761 q"AATT~ ,q"~A']~TIR ~,,'?AT,ITA'T',TC~ST RV, P(qRq" ***** ~TT~ DATA ~A~ ~T,T, O~J'r~.~ ~ P~TOD O~ ON~ ~TT~ T~ .10 ~AT,T,ONA. 15 10 -5 -10 C~ mm -'15 F -.08012 .08818 .Bl?r~ G~ C~lN PTA, UEI]:~IOI~ 1,Z0 SO .TIME ~ ~INLIT~S'J J u 80 8{3/26/96 12/12/95 14:47 8805 326 0576 BFD HAZ MAT DIV ~007 ?ERMll No. Bakersfield Fire Dept OFFICE OF ENVIRONMENTAL SERVICES UNDERGROUND STORAGE TANK PROGRA%"'~- PERMIT APPLICATION TO CONSTRUCT/M_ODIFY UNDERGROUND STORAGE TANK 'PfPE OF APPLICATION_(CHEClg NEW FACtLITY J~MOOIFrC"A'I'ION OFFACILITY Q NEW TANK INSTALLATION AT EXISTING FACILITY STARTING DATE ~ ,,~,¢' ~-' 9/.~ PROPOSED COMPLETION DATE '~,q~¢-.-'Y'~ ~--' FACILI'P/' NAME I:~J~.~F't~ '~,~.~L. EXISTING FACILITY PERMiT'N'o. - FACILITY ADDRE.~5 j C,lt,l~ - J~, ~.,~'~r-..~,~ ~,,~pl~L2~-: ~ ZIP COOE ~_,~.~01 TYPE OF BUSINESS L.ttl,L.,t'"r'( e O.H~'-k-,'.t'f APN TANK OWNER 'J==,/~.~..ll~l~, li~'F'rJJ--~' i- PHONE NO- (?1/~) ADDRESS__~"5/' ~,,1~C~'~. ~¥O'~0¢--' .~t~' ~'OI ClTY~"']aC.~J~O'~O ZiP CODE CONTRACTOR '1~ ~" __.~__ .l~t..hk.!~lE''O CA LICENSE NO- ADDRESS CITY Z1P CODE PHONE NO. BAKERSFIELD CiTY BusINESS LICENSE NO. WORKMAN COMP. NO. 1NSURER BREiFLY DESCRIBE THE WORK TO BE DoNE .I~P---N~. V~ ~ 'l~t~ ~ 1343~!'._ ; ,"~!..'¢~.~3.~-'~ ' WATER TO FACILITY PROVIDED BY. DEPTH TO GROUND WATER i0o'-~'~---~'1'' SOIL TYPE E×PECTEO,~TSJTE No. OF TANKS TO BE iNSTALLED' ~14~.. ARE THEY FOR MOTOR FUEL -~:J'YES ~NO SECTION FOR MOTOR FUEL TANK No_ VOLUME UNLEADED REGULAR PREMIUM DIESEL AVIATION 5ECT1ON FOR NON MOTOR FUELSTORAGE TANKS TANK NO. VOLUME CHEMICAL STORED CAS NO. (no Drand name) (if known) CHEM1CAL PREVIOUSLY STORED ....... FOR ~IF~ C AL U~E ONLY ......... ~...":'E'::_::'"" ::" :-;--::: .-;:-~-:::;':';':.2'."-'-"':'. '... , .......... :: . .- .......... .., ,, ...... THE APPLICANT HAS RECE[VED. uNDERSTANO$. AND W~tL COMPLY WITH THE ATTACHED CONDIT[ON$ OF THIS PERMIT AND ANY OTHER sTATE. LOCAL ANO FE{]EJtAL REGULATIONS- THl$ FO'PM HA5 BEEN COMPLETED UNOER PENALTY OF PERJURY. AND TO THE i~EST OF MY KNOWLEDG[. IS Tr',UE AND COI~RECT. ~P R~N h. ~ 4 p p ~A ~ S~e~A TURE THIS APPLICATION BECOMES A PERMIT WHEN APPROVED 12/12/95 14:45 8805 326 0576 BFD HAZ MAT DIV BAKERI~FIELD FIRE DEPARTPI,~s~T DATEI-x~M~. ,g~; 19_~ W BUREAU nF FIRE PR~VF. NTI~ Auto Tire Rebldg. Plants Auto Wrecking Junk Yard Wamte Handling marling Alley Cellulose-Nitrate Combustible Fibres Compressed Oas Duet Explosion Explosives ~is~. Ammunition F1 a~mable Finishes Spray Finishes ~ Flammable Liquids Fumigat ion Garage Hazardous Chem. Liquefied Pet 6as Lu=ba~ Yard Hagnegiu= ~002 Hatches Place of As-embly Tent Welding i cutting Notion Pic Project Airport-Heliport Organic Coating High Piled Stock Extin. System Smoke Evac. Symtem This card is to remain in a conapicious place near the installation until final inspection is made and approved. Remarks: , Final Inspection: 19 Inspector: BAKERSFIELD FIRE DEPARTMENT D,],. APPLICATION In conformity with provisions of pettlnent ordinances, codes and/or regulations, application is mode by: Na.~ of Camoony Addm~ ~ to display, ~ore, instil, u~, ~rote, ~11 or handle materials or prieStS involving or creating con- ditions dee~d hazar~us ~ life or pro~ as foll~s: 12/12/95 14:45 '~805 326 0576 BFD HAZ MAT DIV ~0__03 : ~~~.'~ Bakersfield Fire Dept OIF~JIcE OF ENVIRONMENTAL i~J[RVICES PERMIT APPUCATION FOR REMOVAL OF 'AN UNDERGROUND STORAGE TANK SITE INFORMA_'~_ON SITE __-~'J,c_t~-te... ~ - ADDRESS ic11,~'}~ ¢_~~IP CODE 3~l APN FACILI~NAME ~~ ~. CROSS STREET ~ ~ TANK OWNERIO~ERATOR ~~ ~ PHONE No. MAILING AODRESS~~ ~~t ~; ~-Ol_ C[~ ~ ZIP CODE CON11~ACTOR INFORMATID_N= COMPANY ADDRESS PHONE No. INSURANCE CARRIER LICENSE No. CiTY ZIP CODE WORKMENS COMP No. PRELIMANARY ASSEMENI' INFORMATION COMPANY ADDRESS PHONE No. INSURANCE CARRIER LICENSE NO. CITY ZIP CODE WORKMENS COMP No. TANK CLEANING INFORMATION COMPANY ADDRESS WASTE TRANSPORTER IDENTIFICATION NUMBER NAME OF RINSTATE DISPOSAL FACILITY ADDRESS FACILITY INDENTIFICATION NUMBER PHONE No. C1TY ZIP CODE CITY ZIP CODE TANK TRANSPORTER INFORMATION COMPANY ADDRESS PHONE No. TANK DESTINATION LICENSE No. C[TY ZIP CODE TANK INFORMATION TANK No. AGE VOLUME CHEMICAL DATES CHEMICAL STORED STORED PREVIOUSLY STORED ...:~,,.:....^..:..:,.:.,:~:,~:-,-,-.::,.~.~.¥.',x....,.,..,.,,,.,....:,':~::;'~'~.C~;~:.,,.: .:~;.r.,...,~,:x,,,..^.,....,..,.::F...~'.. ':' *.:.;~.:~.~*'.x.x.~.,:.~.r.,.~..4~.,.^. ~,~:~',~.F'~.'~..~:-.^-,~,.~.,'--.-',~ .- -c -' ' ~;"~'~'~-' :~-: ' -- · '. ............................ :s;'~.:.:~-.---:- ............................... ;'::~s::::~:':~r; .............. .. '-: '": "-":,.'.:~.,~-'~:-~:- ............... ,~ .......... ~-..:*.-. ~. f:- : .- '~.~.,-~.~.~::J-.~ ..... : .......................... ......................................................... · ....... . ........ ....,~ ............ ~, x..~ ~[ N ........................ .............. - .... ~, ....................... ~¢t[[~ N' ~-:* ......................................... ~ ......... ~ ........ . ..................... · ::.-.:::~!i;~;~i;~,:.~::~.-:~,~!:':~':,:~;c:;!~::'. ~;:]:-; j ' .. ~..i. '.~,. ...................... ~.~.~.F~j!.:.~!``:^::;;;~ic:c:~:r~!:~!:~.::~.~:r:!~:r~;:~.~.~..~.~:s;;:`..::;:pi~v~`:.~.~`:-'~-~ *---~: ......... ' ............. ~:'-'-':-,:~: ~ .................. '";T '; '. ......... ' .................. THE APPLICANT HA~ RECEIVED. UNDERSTANDS. AND W~LL COMPLY WITH THE A~ACHED CONDITIONS OF TH~S PERMIT AND ~NY OTHER STATE. LOCAL AND FEDERAL REGULATIONS, THIS FORM HAS BEEN COMPLIED UNDER PENAL~ O~ PEnUrY, AND TO THE BEST OF MY KNOWLEDGE. IS TRUE AND CORRECT. ..... APPLICANT ~AME ~iN~ ~ ~LI~A~T'SIGNATURE THIS APPLICATION BECOMES A PERMIT.WHEN APPROVED. AUG-27-1996 12:50 ON~XYZ200 200 PACIFIC BELL BKFD 12 1918 M ST. BAKERSFIELD CA. JUL 10, 1996 11:43 AM FROM SACTO FLEET ADMIN CENTER TO 180532605?6 P. 01 I~1~/I ,¥0 t TANK PRODUCT 1 . DIESEL' ~llB9 ONEXYZI30100 I30100 JUL 10, 1996 11:43 A~ GALLONS INCHES WATER DEG F ULLAGE 18493 97.19 0.0 86.6 1656 PACIFIC BELL BKFD 12 1918 M ST. BAKERSFIELD CA 1 DIESEL-ANNULAR SEN~ I 0200 i~i~ ~ s~. ' k' · - "~.~t).~ BAKeRSFIeLD CA ~ , 2 DIESEL-S~ ~L 8,~ 1996 1:29 PM LIQUID JUL 8,' 1996 12:12 JUL 9, 1996 1:00 JUL 9, 1996:12:49 A~ STATUS / v~..~......~. ~ A~ ESOP CO~A_~¥ ROBERT-H.LEE & ASSOCIATES, INC. ARCHITECTURE ENGINEERING ENVmONMENTXL SERVICES JOHN W. JOHNSON Architect ~ Co-President BRIAN F. ZITA Architect Co-President JOHN B. HICKS Architect Vice President CECIL R. SPENCER Architect Vice President JAMES H. RAY Civil Engineer BRUCE J. GREENFIF, LD Architect Associate HOWARD G. KIMURA Associate GARY M. SEMLING Architect Associate BLYTItE R. WILSON Architect Associate June 27, 1996 Bakersfield Fire Department Ralph Huey 2130 G Street Bakersfield, CA 93301 RE: UNDERGROUND STORAGE TANK WRITTEN MONITORING PLANS Dear Ralph Huey: Enclosed are the Underground Storage Tank Monitoring Plan(s) and related documents for the Pacific Bell facilities as listed on the attached sheet. If there are any further correspondences related to these submissions, please direct them to: Pacific Bell Nancy Clancy 2600 Camino Ramon, Room 1N200 San Ramon, CA 94583 Sincerely, ROBERT H. LEE & ASSOCIATES, INC. Project Manager Enclosure cc: Nancy Clancy - Pacific Bell File ~9 MARmTTA, GA SACRAIfl~NTO, CA BELLY. V-erE, WA LA H/amA, CA BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA 93301 (805) 326-3979 APPLICATION TO PERFORM A TIGHTNESS TEST FACILITY PERMIT TO OPERATE # OPERATORS NAME ~{-L. ~L NUMBER OF TANKS TO BE TESTED / ADD~ESS !9~ ~ s~ OWNERS NAME IS PIPING GOING TO BE TESTED'~(.~7~ TANK# VOLUME CONTENTS / TANK TESTING COMPANY ~DRESS TEST METHOD N~E OF TESTER DATE & TIME TEST IS TO BE CONDUCTED DATE SIGNATURE OF APPL~NT Pacific Bell Underground Storage Tank(s) Written Monitoring Procedures and Emergency Response Plan 1996 Pacific Bell - SA004 (Facility Name and 139) 1918 M STREET (Facility Address) BAKERSFIELD (Facility City) (Facility County) Certification I hereby certify that all monitoring and maintenance of the UST(s) and equipment will be conducted as required by Article 5, Title 23, CCR. To the best of my knowledge, under penalty of perjury, that the information contained in this Underground Storage Tank Monitoring Plan is true and correct. I understand that I may be required to show proof of compliance during any facility inspection conducted by local, County, State or Federal authorities. Authorized gi[gnature / Print Name (~'/~,,"/~0- Q, Environmental Management Date Title Facility Information Date: June 17, 1996 Facility Name: Pacific Bell (BKFDCA12} Street Address: 1918 M STREET Business Type: Telecommunication EPA ID//: CATO80020415 Mailing Address: P.O. Box 5095, Room 1N200. Billing Address: P.O. Box 601883 Shift 1 Employees:9 Shift 2 Employees: Shift 1 Start: Shift 2 Start: Shift 1 End: Shift 2 End: Facility ID:_SA004 City: BAKERSFIELD D & B#: 10-340-1618 Uniform Building Code Class: B1 City: San Ramon City: Sacramento Zip:93301 SIC Code: 4811 Zip: 94583-0995 Zip: 95860-1883 Shift 3 Employees: Shift 3 Start: Shift 3 End: Primary Contact: Title: Secondary Contact: Executive Contact: Title: HMMP Contact: Title: Property Owner: Mailing Address: City: LIZ BORGE Site Manager Emergency Control Center 24 hours/day Nancy Clancy . Corporate Environmental Management Robert H. Lee & Associates. Inc Mr. Steven A. Skanderson Environmental Manager Pacific Bell P.O. Box 5095, Room 1N200 San Ramon, CA Phone Number: 209-454-3314 Phone Number: 916-977-7777 Phone Number: 415-331-0924 Phone Number: 800-765-1025 Phone Number: 415-331-0924 Zip: 94583-0995 Adjacent Properties Direction North: South: East: West Business Name Contact Phone Special Land Uses (within) 1 mile) Direction Business Name Contact Phone Water Table (ft):UNKNOWN Flood Zone:unknown Earthquake Faults:None within 1 mile pg. 1 Emergency Response Plan Facility Name: Pacific Bell Date: June 17, 1996 Facility ID:SA004 All Personnel Internal Notification: Yes Offsite Notification: N/A ER Plan Location: Yes Evae. Procedures: Yes Spill Procedures: Yes Chemical Handlers Hand/Store Method: Yes PPE: Yes Spill/Fire Equip: Yes Exposure Hazards: Yes Emergency Response Team Rescue: No Shutdown: Yes ER Equip. Maint: Yes ER Procedures: Yes Annual Retrain: Yes Emergency Response Documents Verify training Yes Desc. training: Yes 3 year archived Yes Drill documentation Yes Evacuation Notification Shouting: Yes Horns: Yes Alarms: Yes P A Systems: Yes Telephones: Yes Evacuation Procedures Assembly Area: Yes Maps: Yes Re-entry: Yes Emergency Contacts Emergency: Fire/Police/Ambulance: State Agency: Other Agency Name: Other Agency Phone: 916-977-7777 911 800-852-7550 Bakersfield Fke Department 805-326-3979 Nearest Medical Facility: dial 911 for local assistance Name: Address: City: Phone: Other Evacuation Planning Information Emergency Response: Pacific Bell Emergency Control Center: 916-977-7777 (24 hrs. a day) Abnormal, hazardous and emergency conditions which may effect service, company building and/or adverse publicity should be reported to the Emergency Control Center. This organization maintains the names, home addresses and phone numbers (office and home) of contact persons who are qualified and authorized to assist federal, state and local emergency response personnel in the event of an emergency. The center is manned on a 24-hour per day, 7-day per week basis. pg. 2 Emergency Response Plan Facility Name: Pacific Bell Date: June 17, 1996 Facility ID:SA004 Equipment Location: Engine Room Responsible Inspector: Power Supervisor Personal Protection Equipment First-Aid Kits Eye Wash stations Gloves Hard Hats Safety Glasses Spill Control Equipment Brooms Fire Extinguishers Neutralizers Location: 1 of 2 Inspection Frequency: Monthly Communication Devices Telephones Verbal Pa System Pagers Equipment Location: Responsible Inspector: Sacramento Fuel Unit Location: 2 of 2 Inspection Frequency: Daily Personal Protection Equipment Spill Control Equipment Veeder Root TLS-350 Communication Devices pg. 3 Tank Monitoring Equipment Facility Name: Pacific Bell Date: June 17, 1996 Facility ID: SA004 Inventory control monitoring of the fuel and long term tank monitoring for product leakage is accomplished with in-tank continuous product monitoring provided through the installation of the TLS-350 Tank Level Sensor manufactured by Veeder-Root. The TLS-350 consists of a Computerized Inventory Monitor (CIM) and one Digital Sending Probe (DSP) for each tank being monitored. The highly accurate, all electronic probe has no moving pans for greater accuracy and less maintenance than other electro-mechanical, float-type devices. A single CIM can handle multiple probes and continuously monitor each one, analyzing their signals for liquid, temperature, depth and water level. Based on this input, the CIM computes volumes and stores this information for remote polling. The RE-232C Serial Interface Communication port permits access to TLS-350 information from remote locations via telephone lines. This serial interface is capable of handling up to 16 polling stations from centralized remote locations. The output of the serial port can be formatted for teletype or computer (IBM-PC) interface. The TLS System has four modes of operation - Leak Detection, Tank Detection, Interstitial/Piping Sump Lead Detection and Automatic Delivery Reporting. When the leak monitor mode is activated, the TLS System continuously monitors fuel levels in each tank and can detect losses of 0.2 gph. An hourly report on each tank shows temperature-compensated inventory changes to 0.1 gallon based on inventories when the tank leak mode is initiated. The Leak Monitor is activated through a push-button mounted on the front panel, or remotely through the RS-232 Telecommunications Interface. The Tank Inventory Report presents the current status of each tank. It provides station location, date and time, volume and level of fuel, water level and temperature. Interstitial/Piping Sump Leak monitoring will be provided using two liquid sensors placed in the double wall tank annular space and in the tank manhole space. The LED display on the TLS console will flash indicating the alarm cause and location. The Automatic Delivery Increase Report features are generated two minutes after fuel is delivered to the tank. The printout includes date, time, volume and temperature before and after the increase and the net increase of inventory. Pacific Bell's UST/IS database system automatically calls the TLS monitoring system and "reads" alarms and tank data four times per day. The alarms are investigated by our personnel in the centralized Fuel Administration Center located in Sacramento, California. In the event the on site TLS device panel indicates an alarm condition the Power Room/Fleet personnel are instructed via an "In Case of Alarm" Notice posted on the device panel to contact the following: Power Room Supervisor, Site Manager, Real Estate Facility Engineer, Fuel Administrator Center. All equipment used in implementing the monitoring program shall be installed, calibrated, operated and maintained in accordance with the manufacturer's instructions, including routine maintenance and service checks. The system is inspected once per calendar year by a third party in accordance with Article 5, Title 23, CCR. Copies of the recertification report shall be sent to the administering agency and copies will be maintained on site. pg. 4 Emergency Response Plan Facility Name: Pacific Bell Date: June 17, 1996 Facility ID: SA004 Separation of Materials This facility does not store material by type of quantity which requires special separation consideration. The facility was designed to prevent fire or explosion in accordance with applicable National Fire Prevention Association Guidelines and local fire codes. The material of construction is compatible with the product stored. The tank(s) is secured to prevent unauthorized inputs or withdrawals. Monitoring Program - Fuel Storage Tanks The monitoring program consists of an "initial" precision leak test using the Homer "Ezy-Chek" technique (or equivalent) followed by in-tank product monitoring. Recordkeepin~ Recordkeeping is accomplished by a mechanized database that automatically polls the in-tank monitor daily. Records will be made available to any agency of jurisdiction within 24 hours via fax. Requests for data should be called to Pacific Bell's Sacramento Fuel Unit on 916-972-4377. All recordable leaks and spills will be recorded on a Hazardous Material Incident Report, Form Number FR-0023. Emereency E~_uipment A number of fire extinguishers are kept on the premises at all times. They are placed at strategic locations throughout the facility in accordance with the protection requirements of NFPA 10. Additional emergency equipment will be obtained as needed form Pacific Bell contracted hazardous material and hazardous waste handling vendors. The fire extinguishers are maintained and serviced by a professional outside contractor on a yearly basis. A visual inspection is made by the facility wardens on a regular basis to ensure the adequacy of the emergency equipment. Contingency Plan Unauthorized releases (leaks and spills) of petroleum products will be recorded utilizing the Hazardous Materials Incident Report Form Number FR-0023 and reported by the operator of the underground storage tank immediately to the following: 1) Bakersfield Fire Department, 805-326-3979 2) Office of Emergency Services 800-852-7550 3) National Response Center 800-424-8802 4) Pacific Bell Emergency Control Center 916-977-7777 5) Environmental Management (415) 331-0924 6) Real Estate Department Reports Center 800-953-1006 7) Respective upper management within group. pg. 5 Emergency Response Plan (cont.) Facility Name: Pacific Bell Date: June 17, 1996 Facility ID: SA004 In case of fires, the local Fire Department and Pacific Bell Emergency Control Center will be notified promptly by the operator of the underground tank. In each step of notification, documentation will be prepared to include: 1) Location 2) Specific description and location of the area involved 3) Time and date of occurrence 4) Description of spill and type of material 5) Approximate quantity of material that spilled/leaked All recordable leak and spill records will be maintained on the site. The key personnel on the site (Building Warden and Site Manager) are trained for responding appropriately to any major catastrophe. A training program conducted by the training department of Pacific Bell provides the information to the key personnel regarding emergency telephone numbers, reporting requirements, location of emergency equipment and evacuation procedures. This information is true and correct. If there is any change which would materially effect the Hazardous Material Management Plan, we will amend the appropriate sections. pg. 6 Tank Construction Facility Name: Pacific Bell Date: June 17, 1996 Facility ID: SA004 Tank Number: Tank Number: Tank Number: Tank Capacity:20000 Tank Capacity: Tank Capacity: Fuel:DIESEL2 Fuel: Fuel: WalI:DW Wall: Wall: Installation: 1996 Installation: Installation: Tank Manufacturer:MODERN WLD Tank Manufacturer: Tank Manufacturer: Tank Material:COMP Tank Material: Tank Material: TANK//4 TANK #5 ]] TANK #6 Tank Number: Tank Capacity: Fuel: Wall: Installation:0 ~ Tank Manufacturer: Tank Material: Tank Number: Tank Capacity: Fuel: Wall: Installation: Tank Manufacturer: Tank Material: Tank Number: Tank Capacity: Fuel: Wall: Installation:0 Tank Manufacturer: Tank Material: Piping Construction: DW-ENVIROFLEX Piping Material: EF Piping Type: SUCTION pg. 7 Date:~ WRITTEN MONITORING PROCEDURES UNDERGROUND STORAGE TANK MONITORING PROGRAM This monitoring program must be kept at the UST location at all times. The information on this moniwring program are conditions of the operating permit. The permit holder must notify Bakersfield Fire Department within 30 days of any changes to thc monitoring procedures, unless require~i to obtain approval before making the change. Required by Sections 2632(d) and 2641(h) CCR. Facility Name PACIFIC BELL (SA004) Facility Address 1918 M STREET, BAKERSFIELD A® Describe the frequency of performing the monitoring: Tank: Daily Piping: Daily Be What methods and equipment, identified by name and model, will be used for performing the monitoring: Tank: Veeder Root TLS-350 Piping: Veeder Root TLS-350 Describe the location(s) where the monitoring will be performed (facility plot plan should be attached): The monitoring will be performed at the site - the TLS-350 alarm panel is located in the ENGINE/POWER ROOM and also monitored remotely by the Sacramento Fuel Unit. De List the name(s) and title(s) of the people responsible for performing the monitoring and/or maintaining the equipment. Sacramento Fuel Unit, Jeff Kunz\ 916-972-7377 Reporting Format for monitoring: Inventory control monitoring of the fuel and long term tank monitoring for product leakage is accomplished with in-tank continuous product monitoring provided through the installation of the TLS-350 Tank Level Sensor manufactured by Veeder-Root. The TLS-350 consists of a Computerized Inventory Monitor (CIM) and one Digital Sending Probe (DSP) for each tank being monitored. The highly accurate, all electronic probe has no moving parts for greater accuracy and less maintenance than other electro- mechanical, float-type devices. A single CIM can handle multiple probes and continuously monitor each one, analyzing their signals for liquid, temperature, depth and water level. Based on this input, the CIM computes volumes and stores this information for remote polling. The RE-232C Serial Interface Communication port permits access to TLS-350 information from remote locations via telephone lines. This serial interface is capable of handling up to 16 polling stations from centralized remote locations. The output of the serial port can be formatted for teletype or computer (IBM-PC) interface. pg. 8 Reporting Forma~r monitoring: (cont.) The TLS System has four modes of operation - Leak Detection, Tank Detection, Interstitial/Piping Sump Lead DeteCtion and Automatic Delivery Reporting. When the leak monitor mode is activated, the TLS System continuously monitors fuel levels in each tank and can detect losses of 0.2 gph. An hourly report on each tank shows temperature- compensated inventory changes to 0.1 gallon based on inventories when the tank leak mode is initiated. The Leak Monitor is activated through a push-button mounted on the front panel, or remotely through the RS-232 Telecommunications Interface. The Tank Inventory Report presents the current status of each tank. It provides station location, date and time, volume and level of fuel, water level and temperature. Interstitial/Piping Sump Leak monitoring will be provided using two liquid sensors placed in the double wall tank annular space and in the tank manhole space. The LED display on the ~ .console will flash indicating the alarm cause and location. The Automatic Delivery Increase Report features are generated two minutes after fuel is delivered to the tank. The printout includes date, time, volume and temperature before and after the increase and the net increase of inventory. Describe the preventative maintenance schedule for the monitoring equipment. Note: Maintenance must be in accordance with the manufacturers' maintenance schedule but not less than every 12 months. All equipment used in implementing the monitoring program shall be installed, calibrated, operated and maintained in accordance with the manufacturer's instructions, including routine maintenance and service checks. The system is inspected once per calendar year by a third party in accordance with Article 5, Title 23, CCR. Copies of .the recertification report shall be sent to the administering agency and copies will be maintained on site. Describe the training necessary for the operation of UST system, including piping, and the monitoring equipment: The key personnel on the site are trained for responding appropriately to any major catastrophe. A training program conducted by the training department of Pacific Bell provides the information to the key personnel regarding emergency telephone numbers, reporting requirements, location of emergency equipment and evacuation procedures. All personnel involved with maintaining the monitoring system have been trained and certified by the manufacturer of the equipment in accordance with Article 5, Title 23, CCR. pg. 9 EMERGENCY RESPONSE PLAN UNDERGROUND STORAGE TANK MONITORING PROGRAM This monitoring program must be kept at thc UST location at all times. The information on this monitoring program are conditions of the operating permit. Thc permit holder must notify Bakersfield Fire Department within 30 days of any changes to thc monitoring procedures, unless required to obtain approval before making thc change. Required by Sections 2632(d)and 2641(h) CCR. Facility Name Pacific Bell (SA004) Facility Address 1918 M STREET, BAKERSFIELD If an unauthorized release occurs, how will the hazardous substance be cleaned up? Note: If released hazardous substances reaches the environment, increase the fire or explosion hazard, are not cleaned up from the secondary containment within 8 hours, or deteriorate the secondary containment, then Bakersfield Fire Department must be notified within 24 hours. If an unauthorized release occurs contact the authorized person(s) listed below in #5. They will make arrangements with Pacific Bell approved contractor for clean-up. Describe the proposed methods and equipment to be used for removing and properly disposing of any hazardous substances. Immediate Action: a. Notify a responsible manager. Determine nature, location, magnitude and severity of incident. b. Move people away from the area as appropriate. c. Contain by arranging physical barriers (i.e. dikes, berms, etc.) Use of sorbents (i.e., neutralizers, oil absorbent material, rags, etc.) d. If there has been a' release into the annular space of the tank, Pacific Bell will immediately order one of their contractors and an approved Hazardous Material/Waste Disposition vendor to the site where removal and cleaning of the annular space would be completed. Testing and replacing of the alarm sensors will be performed as required. Describe the location and availability of the required cleanup equipment in item 2 above. Spill Control Equipment is located in the ENGINE/POWER ROOM Describe the maintenance schedule for the cleanup equipment. Cleanup equipment is inspected monthly by the Power Supervisor. List the name(s) and title(s) of the person(s) responsible for authorizing any work necessary under the response plan: LIZ BORGE / 209-454-3314 / 209-263-3646 Emergency Control Center on 916-977-7777 (24 hours a day). Environmental Management Hotline on 510-823-9833 (8am - 5pm). pg. 10 PACIFIC ~ BELL BUSINESS NAMg PACIFIC BELL BKFDCA12 SAO04 SITg MAP BUSINESS ADDRESS 1918 M STREET BAKERSFIELD DATg 3/22/96 ZiP CODE 7 9 A I C D E F NOFITH DRAWING SCALg NOT TO. SCALE SYMBOL LEGEND M ELECTRICAL PANEL SHUT-OFF NATURAL GAS SHUT-OFF WATER SHUT-OFF EMrRG~NCY PUMP SHUT--OFt TANK MONITORING ALARM 11gJ~.pHONE FIRST AID KIT F1RE EXTINGUISHER STORM 0RAIN SANITARY SE~R STAGING: ARIr~A EVACUA'I1ON / HMMP, AND MSO$ LOGATION F1RE HYDRANT FENCE EMIrRGCNCY RESPONSIr EQUIPMENT/ABSORBENTS ABOVEGR(XJND STORAGE TANK ~1 UNDERGROUND STORAGE TANK MOTOR OILS & LUBRICAN1] (COMaUSTIBLE UQU~OS) BATTERY [LECTROLYll[ (CO~ROr~V[ UQUJD) GASOUNIr (FLAMMABLE U~U~0S) OIESIrL FUEL (COMBUS11BL£ UQUIDS) NI1ROGEN (COMPRIrSSED GAS) PROPANE (FLAMMABLE UQUIO) AClrTYI.ENE (COMPRIrSSED GAS) ANTIFREEZE/COOLANTS WASTE OIL (FLAMMABLE UOU~O) FIRE PULL BOX BAKERSFIELD FIRE DEPARTMENT June 18,1996 FIRE CHIEF MICHAEL R. KELLY ADMINISTRATIVE SERVICES 2101 'H' Street Bakersfield, CA 93301 (805) 326-3941 FAX (805) 395-1349 SUPPRESSION SERVICES 2101 'H" Street Bakersfield, CA 93301 (805] 326-3941 FAX (805) 395-1349 PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 (805) 326-3951 FAX (805] 326-0576 ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 [805] 326-3979 FAX (805) 326-0576 TRAINING DIVISION 5642 Victor Street Bakersfiela, CA 93308 (805) 399-4697 FAX (805) 399-5763 Dear Underground Storage Tank Owner: Enclosed is your updated Permit to Operate for the underground storage tank(s) located at the referenced place of business. Please take a moment to review the information printed on the permit to make sure everything is correct. If any corrections need to be made, please call the discrepancies to our attention immediately. Your Permit to Operate is a legal document and its accuracy determines whether you are in compliance with the law. If you are the tank owner and not necessarily the tank operator at the site, please make a copy of this permit for your own files. Forward the original permit to the tank location so that it may be conspicuously posted on site. if you have any questions regarding the Permit to Operate or your responsibilities as an underground storage tank owner, please call the Office of Environmental Services at (805) 326-3979, or write to us at the letterhead address. Sincerely, Ralph E. Huey Hazardous Materials Coordinator Enclosure P, rmit t,i, Op, rat, Underground Hazardous Materials Storage Facility CONDITION:: P REVERSE SIDE Tank Hazardous :::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: .... y ea'{;~:i?~!?:.::::.. :i~:: :(~.:T ank '"::;::.;'T:a~i~:~:~!;iii'::i!i:!?::~::;: Piping Piping Piping Number Substance CaPa~ii:~%.:':?' I ns talled :':i.-.:.. ~.~ ?T y p e M o'h:i f~:~i~9 ?::.:~:?:~. Type Method Monitoring ..:.. ...:, :.:.:.:.:..,. :... ::~::: '.. . ..;:.,:::~:::.. '.:.============================ i~ .....'.'::~ .....:::::.:.... · :i: .., .":':~il :::::i.., .'...,.~::~..:~;:~ '.'-::::::?:~:.~::;::' .... ~:~ ....... :::. :~::~::~::: ~..:..: ::::::::::::::::::::::: .............. 01 DIESEL ~ 2~::'~?: ~:'~' :'::.::.::~]:::;.:::;~::~:.~}~?~??~ ~?::??~:'?'~:S::~ -: .... C L[~?~?:~}):.: :~ ~?.FLEX PRESSURE ALD .:~::~,, ,... :~.. · .............  PACIFIC BELL HAZARDOUS MATERIALS DIVISION 1715 Chester Ave., 3rd Floor 1918 "M' STREET Bakersfield, CA 93301 BAKERSFIELD, CA 93301 (805) 326-3979 ~pprovod b~: ......... Valid from: 07-0B-9~ to: O~.-OB-O~ ~AKERSFIELD FIRE DEPART~E~' ENvIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA 93301 (805) 326-'3979 TANK REMOVAL INSPECTION FORM OWNER PAc ~oAI . PERMIT TO OPERATE# CONTRACTOR j}.~, $c~.,~% CONTACT PERSON-T~.~, LABORATORY '~D~c~.ee_ [ ~ # OF SAMPLES TEST METHOD~IIOGY~ 'T6%. PRELIMANARY ASSESSMEf~T CO. 2/'7- CONTACT PERSON CO2 RECIEPT -{~ LEL% ~> 0~% PLOT PLAN CONDITION OF TANKS ?~r__ Bell ~Lba t>~ Lk,ST CONDITION OF PIPING CONDITION SOIL DATE INSPECTORS NAME SIGNATURE J~ b BL)O, PP~ ~q PP/'h BAKtSFIELD CITY FIRE DEPAR ENT OFFICE OF ENVIRONMENTAL SEI IfflCES INSPECTION RECORD -PC3T CARD *~ ....... PHONE NO. q I (o '~ 7 ..~-' Z'I O~ ~ PERMIT # ~;;~O[ ~ INSTRUCTIONS: Please call for an inspector only when each group of inspections with the same number are ready. They will run in consecutive order beginning with number 1. DO NOT cover work for any numbered group until ell items in that group are signed off by the Permitting Authority. Following these instructions will reduce the number of required inspection visits and therefore prevent assessment of additional fees. TANKS AND BACKFILL INSPECTION [ DATE [ INSPECTOR Backfill of Tank(s) Spark Test Certification or Manufactures Method Cathodic Protection of Tank(s) PIPING SYSTEM Corrosion Protection of Piping, Joints, Fill Pipe Electrical Isolation of Piping From Tank(s) Cathodic Protection System-Piping S. ECONDARY CONTAINMENT, OVERFILL PROTECTION, LEAK DETECTION Uner Installation - Tank(s) liner Installation - Piping Vault With Product Compatible Sealer Level Gauges or Sensors, Float Vent Valves Product Compatible R,I Box(es) Product Une Leak Detector(s) Leak Detector(s)for Annular Spaco-D.W. Tank(s) Monitoring Well(s)/$ump{s)- I-I~0 Test Leak Defection Device(s) for Vadose/Groundwater FINAL Monitoring Wells, Caps & Locks Monitoring Requirements CONTRACTOR LICENSE ~ Auto Tire Bebldg. Plants ~ A;to Wrecking 0 Junk Yard kJ #ante X~ndli~g 0 Boelin~ Alley 0 Cellulose Nitrate 0 Combustible ~ib~es 0 Compressed Gan ~ Dust Explosion Haz. ~ ~xplosives ~ ~ise. iBARI~4~FIC_! n FI~ DEPART Auunition Flammable Finishes Spray ~inishes Flammable Liquids Fumigation Garage Hazardous Chem. Ei~ua~ied Pe~ ~agneeium Place o£ Assembly Tent Weldin~ & cutting No~ion Pic P~o~ec~ Airport-Heliport. Organi~ Coa~ing High Piled Stock Bxtin. 5ya~sm This card is to remain in a conspicious place near the installation until final inspection in made and approved. Remarks: , ~tnal Inspection: 19 Inspector: BAKERSFIELD FIRE DEPARTMENT BUREAU OF FIlE PKEVEKTIO# APPLICATION in conformity with provisions of pertinent ordinances, codes and/or regulations, application is made ON" to display, store, install, us~, operate. ~ll or handle materials or proceSSeS involving or creming con- dit,ons deemed hazardous to life or property as follows: This Memorandum is an acknowledgment that a Bill of Lading has been issued and is not the Original Bill of Lading, nor a copy or a duplicate, covering the property named herein, and is intended solely for filing or record, RECEIVED, subject to classifications and lawfully filed tariffs in effect on the date of the receipt by the carrier of the property described in the Original Bill of Lading the property descr bed be ow, n apparent good order except as noted contents and cond t on of contents of packages unknown), marked, consigned, and des'tined as indicated below, which said carrier (the word carrier be ng understood throughout this contract as meaning any person or corporation in possession of the property under the contract) agrees to carry to its usual place of delivery at said destination, if on its route, otherwise to deliver to another carrier on the route to said destination. It is mutually agreed, as to each carrier of all or any of said property over all or any portion of said route to destination, and as to eachpart¥ at any time interested in all or any of sa d property, that every serv ce to be performed hereunder shall be subject to all the terms andconditions of the Uniform Domestic Straight Bill of Lading set forth {1) in Official, Southern; Western and Ulinois Freight Classifications in effect on the date hereof, if this is a rail or a rail-water shipment, or 12) in the applicable motor carrier classification or tariffif this is a motor carrier shipment. Shipper hereby certifies that he is familiar with all the terms and conditions of the said bill of lading, including those on the back thereof, set forth in the classification or tariff which governs the transportation of this shipment, and the said ten~s and conditions are hereby agreed to by the shipper and accepted for himself and h~s assigns. rFrom ~¢.~ ~1~. ~ ~_~:~7 8~ ~~3 BESIGNATE WITH AN IX) At ~-~.~, ~.~_~ BY TRUCK I I FREIGHT I I Shipper's No. Carrier ,~odern ~e[d:~l~ Co o¢ Ca [~(: {SCAC) Carrier's No Consigned to Shields, t{arper & CO % Pacific ~e11 IMSIl or street address of consignee - for purpose Of notification only.) On C~llect on Delivery shipments, the letters '*COD" must appear before consignee's name or as otherwise provided in item 430.Sec. 1. ,n Bakersfield Route Delivering Carrier S" N.o.o.f.., I"~";~"."'1 Description of Articles Special Marks and Exceptions 1 20,000 ~allon Double l~all Glasteel I i co~o~i~ Under,round tan~k. -' 1 [ [Glas~eel field kit " hold do~m ~raps & pads State C a County Delivery Address* 191g .~-~ S~;r~O[ ( * To be filled in only when shipper desires and governing tariffs provide for dsiive~y thereat.) Vehicle or Car Initial '.O~, ~ ' No. ~ Ce ~- · Weight Subject to section 7 of conditions (Subject to Corr.) of applicable bill of lading, if this ship- ment is to be delivered to the con- signee without recourse on the con- 5 0 0 ~' sig .... th ..... ig .... hall sign the following statement: The carrier shall not make delivery of this shipment without payment of freight and all other lawful charges. g to the 1' "This is to certify that the above named materials are properly classified, described, packaged, marked and labeled, and are in prope~ applicable regulations of the Department of Transportation." * If the shipment moves between two ports by a carrier by water, the law requires that the bill of lading shall state whether it is "carrier's or shipper's weight." t Shipper's imprints in lieu of stamp; not a part of Bill of Lading approved by the Department of Transportation. ~ NOTE - Where the rate is dependent on value, shippers are required to state specifically in writing the agreed or declared value of the property. /~,),/ The agreed or declared value of the property is hereby specifically stated by the shipper to be not exceeding REMIT C.O.D. TO: THIS SHIPMENT IS CORRECTLY DESCRIBED. t The fibre boxes used for this shipment conform to the specifications set [ C.O.D. CHARGE ( SHIPPER [] I forth in the box maker's certificate thereon,i ands ~f all other requirements of I TO BE PAID BY ( [ Item 222, of the National Motor Freight C a s' ication/ / ,' [ CONSIGNEE [] CORRECT WEIGHT IS LBS ~.[~_-~ ~;~r~,~.'~.~. ~r~? ~ ~ ~--~. ~ Sh~pper /~¢ / ) ,' .,' / /' '/~ff/Agent Per / ,~,,..~ ~..~.,(_.~ z~..~- Per Per (Signature of If charges are to be prepaid, write or stamp here, "To be Prepaid." Received $ to apply in prepayment of the charges on the property described hereon. Agent or Cashier IThe signature here acknowledges only the amount prepaid.) Charges Advanced: $ C.O.D. SHIPMENT C.O.D. Amt.. Collection Fee Total Charges Permanent post office address of shipper * MARK WITH "X" TO DESIGNATE HAZARDOUS MATERIAL AS DEFINED IN TITLE 49 OF THE CODE OF FEDERAL REGULATIONS. I~/IZ/9$ 14:45 PERMIT APPUCATION FOR REMOVAL OF AN UNDERGROUND STORAGE TANK SITE INFORMA1]_ON SiTE ~-te._. ~ - ADDRESS Iq~b'l~ ~-~'~P CODE FACIUTY NAME _~ ~ ~ C~OSS ~TREET ~ ~ TANK OWN~IOPERATOR ~~ ~ PHONE No. MAIUNGAODRESS~~ ~~t A~ ~ ~-~i. Cl~ ~ ~P CODE CONIRACTOR INFOR MATI.O.N COMPANY ADDRESS PHONE No. INSURANCE CARRIER LICENSE No. CITY ZiP CODE WORKMENS COMP No. PREI. IMANARY A$$EMENT INFO, RMATION COMPANY *"T'b ~ ~N;.~ ADDRESS PHONE No. INSURANCE CARR[ER LICENSE NO. CITY 7_JP CODE WORKMENS COMP No. TANK CLEANING INFORMATION COMPANY ~ . _~_-*_ ADDRESS WASTE TRANSPORTER IDENTIFICATION NUMBER NAME OF RINS"rATE DISPOSAL FACILII'Y ADDRESS FACILITY INDENTIFICATION NUMBER PHONE No. C1TY ZIP CODE CITY Z~P CODE TANK TRANSPORTER INFORMATION COMPANY .fro ~ ~T~A;-t~W.J~ RHONE No. ADDRESS TANK DESTINATION LICENSE No. C;TY ZIP CODE TANK INFORMATION TANK No. AGE VOLUME CHEMICAL DATES CHEMICAL STORED STORED PREVIOUSLY STORED THE APPLICANT HAS EECEJvED. UNDERSTANOS. ANB WILL COMPEY WITH THE A~A~HEO C~ND~IONS OF THIS P~Mli AND ANY ~TATE. LOCAL AND FEDERAL ~EGULATIONS. THI~ FORM HA~ ~EEN COMPLIED UND ER PENAL~ C~ PEnUrY, AND TO THE BEST OF MY KNOWtED~[ IS TRUE ANO APPUCANT NAME (~INB [ ~LICA~'SIGNATURE THIS APPLICATION BECOMES A PERMIT WHEN APPROVED. · ~,, r- -,-,~ mu: ,,~rrv hi: R&KI:I:::I~FliCLI~= Auto Tire Rebldg. Plants Auto Nrecking Junk Yard #state H~nd ling Boeling Alley Cellulose-Nitrate Co~bustible Compressed Gas Duet Explosion Explosives ~iac. Ammunition Flammable Finishes Spray Piniehee Flammable Liquids tumigation Garage Hazardous Chem. Liquefied Pet Gas Lumbe~ Yard ~stches Place of Assembly Tent ~sldin~ & cutting Hation Pic Project Airport-Heliport Organic Coating High Pilad Stock ixtin. System Smoke ivac. System This card is to remain in a conspiciou~ place near the installation until final inspection is made and approved. Remarks: , Final Inspection: 19__ Inspector: BAKERSFIELD FIRE DEPARTMENT APPLICATION .,~i/cmio~ N-. In conformity with provisions of pertinent ordinances, codes and/or regulations, aDplicotion is made by: -- PERMIT Na. ~li Bakersfield Fire Dept OFFICE OF ENVIRONMENTAL SERVICES UNDERGROUND STORAGE TANK PROGRAI~~- PERMIT APPLICATION TO CONSTRUCT/I~_ODIFY UNDERGROUND STORAGE TANK TYleR OF API~LICAllON_ (CHECK) [] NEW FACILITY J~['MODIFrC'All'ON OFFACtLITY Q NEW TANK INSTALLATION AT EX[ST[NG FACILITY STARTING DATE FACILITY NAME FACILITY ADDRESS TYPE OF BUSINESS TANK OWNER ADDRESS _~1~ ~,-~/. CONTRACTOR ADDRESS PHONE No. WORKMAN COMP. No. INSURER BREIFLY DESCRIBE THE WORK TO BE DONE ..1~. v~ . .A~t~=,'_ ,,~-- I--9J~ PROPOSED COMPLETION DATE .'~. ,~t~-.---t'? ~-',~9--9Lt, 'IP'i,,4~F-tP~ t~,_~J_J ~ EXISTING FACILITY PERMIT No. I fl%~ ' ~_' ~....~_ ,, _l~~-t~J-.~m-: ~ ZIP CODE L71~ J_t-r'f ~_ APN .'~,k.P..~F-I~L, IF~F.J ~- PHONE No..('~1/~) /~,I~IL ~¥~o~, g~. ~-OI - CITY~I~Git~:~ ZIP CODE CI~ ZIP CODE BAKERSFIELD C[~ 5USINESS LICENSE No. WATER TO FAClL1TY PROVIDED BY- DEPTH TO GROUND WATER No. OF TANKS TO BE iNSTALLED SOIL TYPE EXPECTED,~-T:,~ITE ARE THEY FOR MOTOR FUEL ',~YES ONO SECT1ON FOR MOTOR FUEL TANK No. VOLUME UNLEADED REGULAR PREMIUM DIESEL AVIAT1ON SECT1ON FOR NON MOTOR FUEI. STORAGE TANKS TANK NO, VOLUME CHEMICAL STORED CAS NO. (no brand, name) (if known) CHEMICAL PREVIOUSLY STORED THE APPLICANT HAS [~EC E[VED. UNDEIiSTAN0S. AND WILt COMPLY WITH THE ATTACHED cONDITIONS OF THIS PERMIT ,AND ANY OTHER SLATE. LOCAL ANO FEDERAL ~EGULATJONS- THISF~RM HA5 BEEN COMPLETED UN'ER PENA[~ CF PENURY. AND TO THE BEST ~F MY KNOWLEDGE. tS T~UE AND CORRECT. THIS APPLICATION BECOMES A PERMIT WHEN APPROVED BAKERSFIELD CALIFORNIA FAX ~ansmittai Cover Sheet Bakersfield Fire Dept. O~ce of Environmental Services 1715 Chester Ave. · Bakersfield, CA 93301 FAX No. (805) 326-0576 · Bus No. (805) 326-3979 Today's Date / Z/, z/~;5 Time No. of Pages TO: COMPANY:" ~/q L_~-~ FRO. M:;:;: BakersfieldFire Dept. · Office of Environmental:i:!Sewices D&TEt 19 Auto Tire Rebldg. Plants ~ Ammunition Auto Wrecking D Flammable Finishes Junk Yard ~ Spray Finishes Waste Handling ~ Flammable Liquids Bowling Alley D Fumigation Cellulose Nitrate ~ Garage Combustible Fibres ~ Hazardous Chem. Compressed Gas D Liquefied Pet Gas Dust Explosion Haz. ~ Lumber Yard Explosives ~ Magnesium Misc. I~I~RSF]ELD F:[RE BLIRE~U OF F!RE PREVENT This card is to remain in a conspicious place near the final inspection is made and approved. Remarks: Final Inspection: 19__ Inspector: PERMXT NOt Matches Place of Assembly Tent Welding & cutting Motion Pic Project Airport-Heliport Organic Coating High Piled Stock Extin. System Smoke Evac. System installation until BAKERSFIELD FIRE DEPARTMENT BUREAU OF FIRE PREVENTION Date APPLICATION Application No. In conformity with provisions of pertinent ordinances, codes and/or regulations, application is made by: Name of Company Address to display, store, install, use, operate, sell or handle materials or processes involving or creating con- ditions deemed hazardous to life or property as follows: Authorized Representative issued Permit denied ................................................ By ................................................................................. Date Fire Maeshal Bakersfield Fire Dept ,m~ O/~CE OF ENVIRONMENTAL~I~RVICES UNDERGROUND STORAGE TANK PROGRAM pERMIT N°~ PERMIT APPLICATION FOR REMOVAL OF AN UNDERGROUND STORAGE TANK SITE INFORMATION SITE ADDRESS ZIP CODE APN FACILITY NAME CROSS STREET TANK OWNER/OPERATOR MAILING ADDRESS PHONE No. CITY ZIP CODE CONTRACTOR INFORMATION COMPANY PHONE No. ADDRESS INSURANCE CARRIER LICENSE No. CITY ZIP CODE WORKMENS COMP No. PRELIMANARY ASSEMENT INFORMATION COMPANY PHONE No. ADDRESS INSURANCE CARRIER LICENSE No. CITY ZIP CODE WORKMENS COMP No. TANK CLEANING INFORMATION COMPANY ADDRESS WASTE TRANSPORTER IDENTIFICATION NUMBER NAME OF RINS'TATE DISPOSAL FACILITY ADDRESS FACILITY INDENTIFICATION NUMBER PHONE No. CITY ZIP CODE CITY ZIP CODE TANK TRANSPORTER INFORMATION COMPANY PHONE No. ADDRESS TANK DESTINATION LICENSE No. CITY ZIP CODE TANK INFORMATION TANK No. AGE VOLUME CHEMICAL DATES CHEMICAL STORED STORED PREVIOUSLY STORED THE APPLICANT HAS RECEIVED, UNDERSTANDS. AND WILL COMPLY WITH THE ATrACHED CONDITIONS OF THIS PERMIT AND ANY OTHER STATE, LOCAL AND FEDERAL REGULATIONS. THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE. IS TRUE AND CORRECT. APPROVED BY: APPLICANT NAME (PRINT) APPLICANT 'SIGNATURE THIS APPLICATION BECOMES_A_.PERMIT_WHEN_APPROVED- .. ^ ,.,-- .-., ,~,..~. ~^v^c,~ ,- 'rn TWO ,,~II'V hi= R&i<'I=R$1Fll=LD,, Plot Plan must show the following: ~T 3. 4. 5. 6. 7. Roads and alleys buildings , ~/ '" location of tanks, piping, and dispensers utilities SCALE water wells (if on site) any other relevent information FIRE DEPARTMENT M. R. KELLY FIRE CHIEF CITY of BAKERSFIELD "WE CARE" BAKERSFIELD FIRE DEPARTMENT HAZARDOUS MATERIALS DIVISION 1715 CHESTER AVENUE BAKERSFIELD, 93301 326-3911 UNDERGROUND STORAGE TANK DIVISION CONDITIONS FOR ABANDONMENT OF UNDERGROUND STORAGE TANKS ** Contractors must have the following information on file in order to obtain a permit: 1. Copy of Contractors license 2. General liability policy 3. Workmans compensation policy 4. Site safety plan ** Site assessment/sample collection contractor must have a soil sampling and quality control/quality assurance protocol on file. GENERAL A permit application for an UST abandonment shall be filed and applicable fees paid 5 working days prior to the commencement of work. This permit shall remain on-site during the entire removal process. A. Permit is valid for 90 days. Forty-eight hour advance notice shall be given to the Bakersfield City Fire Department Hazardous Materials Specialist to arrange an inspection appointment. It is the responsibility of the Permittee to obtain any permit required by other regulatory agencies (i.e. Building department and Department of Public Works). Tank Closure activities must follow the Uniform Fire Code and all Federal and Cai-Osha regulations. 0 It is the Contractors responsibility to know and adhere to all applicable laws and regulations regarding the handling, transportation or treatment of hazardous materials. If any contractors other than those listed on permit and permit application are to be utilized, prior approval must be. granted by the Bakersfield City Fire Department Hazardous Materials Specialist. Deviation from the submitted application is not allowed. TANK EXCAVATION, REMOVAL AND DISPOSAL o Abandonment of tanks in place will only be allowed if removal would pose undue risk to an existing structure. Proof of risk and a work plan/proposal shall be submitted to the Bakersfield City Fire Department Hazardous Materials Division for review and approval prior to the commencement of any work activity. Excavation of enough material to expose the top of the tank, removal of contents, high pressure rinsing, and inerting may be done prior to the arrival of the inspector. TANKS MAY NOT BE REMOVED WITHOUT AN INSPECTOR PRESENT. 10. Job site safety and assuring all CAL-OSHA regulations are followed is the contractors responsibility. Excavations, holes, pits, trenches etc. shall be back filled immediately. Any excavations not back filled shall be properly secured as to ensure public safety (i.e. fenced off). Any excavated material from the tank pit, piping runs, etc. not used as back fill will be properly disposed of, or if left on location will be either containerized or covered with suitable material to prevent the emission of hazardous, noxious or unpleasant vapors and/or odors. In addition the material will be properly secured as to ensure public safety (i.e. fenced off). Tanks shall be either decontaminated or transported as hazardous waste. A Hazardous Waste manifest will accompany either the rinsate or the tank and shall be present on site and presentable upon request. The interior of tanks being transported not as hazardous waste (decontaminated) shall have a lower explosive limit (LEL) of no greater than 5% immediately following cleaning and prior to the introduction of CO_~ Ao The contractor shall certify on the inspection form that the cleaning process was properly conducted and the LEL results did not exceed 5%. The decontaminated tank shall be inerted with the introduction of CO2, in the form of dry ice or from canisters. A° A rate of 20 pounds of dry ice to 1000 gallons of tanks capacity, or the corresponding weight of Carbon Dioxide (C02). B. If canisters are used they shall be bonded to the tank(s). C. A receipt for the CO~ shall remain on site and presentable upon request. Prior to the removal of a decontaminated tank the LEL level will be no greater than 5% and the oxygen level will be no greater than 12%. SOIL SAMPLING/PRELIMINARY SITE ASSESSMENT Soil samples shall be obtained under the direction of a professional engineer, geologist, or authorized representative of a state-approved laboratory. Samples shall be collected, at a minimum, from depths of 2 and 6 feet below the tank bottom, dispensers, and product lines and from the following locations: · Tanks less than 1000 gallons - from the center of the tank. Tanks 1000 - 10,000 gallons - 1/3 of the way in from each end. Tanks greater than 10,000 gallons - from the center and 1/4 of the way in the end of the tank. Below all dispensers. Piping - every 15 feet and/or at connections, joints, bends, etc. o Any area of obvious contamination or likely areas of contamination may be required to be sampled. 4. All samples shall be analyzed b~. a state certified laboratory. Soil samples shall be analyzed for all known and suspected substances to have been stored in the tank. 6. All samples will be accompanied by a Chain-Of-Custody sheet. A soil sample report/preliminary assessment shall be submitted to the Hazardous Materials Division with five days after results have been received and shall contain at a minimum the following information. Ao B. C. D. E. F. Name and location of where the tanks were disposed of. Name and-location of where the rinsate was disposed of. A signed copy of the Hazardous Waste Manifest. A tank disposal receipt from the scraping facility. Copies of all lab data sheets and Chain-Of-Custody documentation. A plot plan showing the locations of the buildings, tanks, piping runs, dispensers, and ALL SAMPLE LOCATIONS WITH CORRESPONDING I.D. NUMBERS AND DEPTHS.  PERMIT No. BBkersfield Fire Dept ~ OFFICE OF ENVIRONMENTAL SEFIglCES .. UNDERGROUND STORAGE TANK PROGRAM PERMIT APPLICATION TO CONSTRUCT/M_ODIFY UNDERGROUND STORAGE TANK TYPE OF APPLICATION (CHECK) i~ NEW FACILITY iQ MODIFIZ~T1ON OFFACILITY Ci NEW TANK INSTALLATION AT EXISTING FACILITY STARTING DATE FACILITY NAME FACILITY ADDRESS TYPE OF BUSINESS TANK OWNER ADDRESS CONTRACTOR ADDRESS PHONE No. WORKMAN COMPi No. PROPOSED COMPLETION DATE EXISTING FACILITY PERMIT No. ZIP CODE APN PHONE No. CII'Y ZIP CODE CA LICENSE No. CITY ZIP CODE BAKERSFIELD CITY BUSINESS LICENSE No. INSURER BREtFLY DESCRIBE THE WORK TO BE DONE WATER TO FACILITY PROVIDED BY- DEPTH TO GROUND WATER No. OF TANKS TO BE INSTALLED SOIL TYPE EXPECTED'~'T:'SITE ARE THEY FOR MOTOR FUEL · C~YES QNO SECTION FOR MOTOR FUEL TANK No. VOLUME UNLEADED REGULAR PREMIUM DIESEL AVIATION SECTION FOR NON MOTOR FUELSTORAGE TANKS TANK No. VOLUME CHEMICAL STORED CAS No. (no brand name) (if known) CHEMICAL ~REVIOUSLY STORED THE APPLICANT HAS RECEIVED. UNDERSTANDS, A NO WILL CO MPLY WITH THE ATTACHED CONDITIONS OF THIS PERMIT AND ANY OTHER STATE. LOCAL AND FEDERAL REGULATIONS. THIS FC~RM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY. AND TO THE BEST (DF MY KNOWLEDGE, IS TRUE AND CORRECT. APPROVED BY: APPLICANT NAME (PRINT) APPLICANT SIGNATURE THIS APPLICATION BECOMES A PERMIT WHEN APPROVED BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES GUIDELINES FOR PERMIT TO CONSTRUCT OR MODIFY AN UNDERGROUND STORAGE TANK In order to expedite permit processing, before submitting your permit application(s) for construction, check to see that ail the following are addressed: o Applications must be fully completed or they will be returned; no exceptions. The use of the answer "NA" (not applicable) is unacceptable. State Underground Storage Tank Permit Application forms must be completely filled out. Form A for the Facility and one Form B per tank. Permit fee(s) must be submitted with the application or it will be returned. A. Permits are vaiid for 1 year. Contractors must have current copies of the following information on file with this program: A. Bakersfield City Business Ucense. CUrrent pocket copy with expiration date clearly noted on one of the following contractors' licenses: Generai A, C-61, D-40, C-36, and General B, with restrictions. Current copies of certificates of workers compensation and liability insurance. D. Site safety plans. Provide two sets of a plot plan for the facility. This plan must include location of property lines, ail buildings and openings to each building (such as windows, doors, vents, etc.), nearest road or intersection, all tanks, piping, any fixed source of ignition (i.e., water heaters, forced air AC units, etc.) ail equipment to be instailed, any source of water infiltration, scales, north arrow, and a minimum 100 foot radius around ail equipment. The minimum acceptable scaie is 1" - 16'. Provide two sets of site specific detailed drawings of proposed construction. These drawings must show side and top views of tanks, piping, secondary containment, leak detection and monitoring equipment, overfill protection and ail other equipment required. All equipment must be clearly labeled. The minimum acceptable scale is 1" - 10'. Certification by manufacture(s) of compatibility of tank(s), piping and secondary containment mat,dais with proposed stored hazardous substances. Information chemical composition of stored product(s) if other than motor vehicle fuels. o Building permits (if required) must be obtained at the Bakersfield City Building Department. Construction can not begin without their approved permit. 10. Complete an application for the Air Pollution Control District for any storage tanks which will contain gasoline or aviation grade gasoline. 11. Existing underground piping may not be removed without an inspector from the Office of Environmental Services being present. 12 Soil sampling shall be performed according to the Soil Sampling/Preliminary Site Assessment guidelines provided by this office. No samples may be obtained without an inspector from the Office of Environmental Services being present. STATE OF CAUFORNIA STATE WATER RESOURCES CONTROL BOARD UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM A COMPLETE THIS FORM FOR EACH FACILITY/SITE MARK ONLY r~i 1 NEW PERMIT ONE ITEM ~ 2 INTERIM PERMIT RENEWAL PERMIT AMENDED PERMIT CHANGE OF INFORMATION ['---} 7 PERMANENTLY CLOSED SITE TEMPORARY SITE CLOSURE I. FACILITY/SITE INFORMATION & ADDRESS - (MUST BE COMPLETED) DBA OR FACILITY NAME NAME OF OPERATOR ADDRESS NEAREST CROSS STREET PARCEL it (OPTIONAL) STATE ] ZIP CODE SITE PHONE # WITH AREA CODE C'TYNAME~'/3c/L~ ~/,~------~'~ CA, ' BOX ~ CORPORATION I--'-] INDIVIDUAL [--q PARTNERSHIP r--] LOCAL-AGENCY J'--] COUNTY-AGENCY' r-'] STATE-AGENCY' [---[ FEDERAL-AGENCY' TO INDICATE DISTRICTS ' ° If owner ol UST is a public agency, complele the following: name of Supervisor of division, section, or Office which operates the UST EMERGENCY CONTACT PERSON (PRIMARY) EMERGENCY CONTACT PERSON (SECONDARY). optional DAYS: NAME (LAST. FIRST) PHONE # WITH AREA CODE I DAYS: NAME (LAST, FIRST) PHONE # i ? W,TH AREA CODE I NIGHTS: NAME (LAST, FIRST) PHONE # WITH AREA CObE II. PROPERTY OWNER INFORMATION- (MUST BE COMPLETED) NAME PA C.J ~'C~ ~ MAILING OR STREET ADDRESS P. O, ~:~:x,- ~q~ /~0~ / NZO0 CARE OF ADDRESS INFORMATION bo to Indicate ]-"-I INDIVIDUAL F"-I LOCAL-AGENCY F--! STATE-AGENCY [CORPORATION I-'-I PARTNERSHIP COUNTY-AGENCY FEDERAL-AGENCY STATE I ZiP CODE _ A ~ I PHONE # W TH AREA CODE CITY NAME III. TANK OWNER INFORMATION- (MUST BE COMPLETED) NAME OF OWNER MAILING OR STREET ADDRESS CiTY NAME _ CARE OF ADDRESS INFORMATION ~/ box to indicate ~ INDIVIDUAL r'-'-I LOCAL-AGENCY [--"1 STATE-AGENCY J J~CORPORATION [---J PARTNERSHIP J~ COUNTY-AGENCY ~] FEDERAL*AGENCY IS'T~ ~ PHONE # WITH AREA CODE _ / 5..:3 oo- 7. 7- 7.b IV. BOARD OF EQUALIZATION UST STORAGE FEE ACCOUNT NUMBER - Call (916) 322-9669 if questions arise. TY<TK) HQ /I- 1 ! V. PETROLEUM MST FINANCIAL RESPONSIBILITY - (MUST BE COMPLETED) - IDENTIFY THE METHOD(S) USED ~' box toindicate ,~ 1 SELF-INSURED I'--I 2 GUARANTEE ~ 3 INSURANCE [~ 5 LETTEROFCREDIT ~ 6 EXEMPTION [~] 99 OTHER SURETY BOND ] VI. LEGAL NOTIFICATION AND BILLING ADDRESS Legal notification and billing will be sent to the tank owner unless box I or II is checked. ICHECK ONE BOX INDICATING VVHICH ABOVE ADDRESS SHOULD BE USED FOR LEGAL NOTIFICATIONS AND BILLING: I. II. II1. THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT SNAME (PRINTED & SIGNED) ~ OWNER'S TITLE DATE MON. TH/DAY/YEAR I COUNTY # JURISDICTION # FACILITY, I LOCATION CODE - OPTIONAL CENSUS TRACT# - OPTIONAL SUPVISOR - DISTRICT CODE - OPT/ONAL THIS FORM MUST BE ACCOMPANIED BY AT LEAST (1) OR MORE PERMIT APPUCATiON · FORM B~ UNLESS THIS IS A CHANGE OF SITE INFORMATION ONLY. OWNER MUST FILE THIS FORM WiTH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS FORM A (3/93) FUEL LOGGING REPORT -- NONMETERED TANKS page 2 TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS REMARKS 01 995 18523 01' 995 18522 01 995 18521 01 /1995 18519 01 /1995 18518 01 995 18517 01 95 18516 01 95 18516 01 95 18516 01 95 18515 01 95 18515 01 5 18515 01 5 18515 01 5 18514 01 L995 18513 01 5 18511 01 ~1995 18510 01~ /1995 18348 01 /1995 18347 01 995 18346 01 995 18346 01 /1995 18346 02 995 18346 02 995 18346 02 995 18346 02 95 18347 02 95 18347 02 95 18347 02 95 18347 02 95 18347 02 95 18348 02 5 18348 02 5 18348 02 5 18347 02~ 5 18347 02 .995 18347 02 ~1995 18347 02 ~1995 18348 02 I1995 18348 02 I1995 18349 02 995 18351 02 995 18351 03 /1995 18352 03 995 18352 03 995 18353 03 95 18354 03 95 18354 03 95 18354 probe was put back in correct spot Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 3 TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS REMARKS 03 18355 03 I1995 18355 03 I1995 18355 03 ~1995 18355 03 ~1995 18356 03 /1995 18356 03 I1995 18357 03 ~1995 18358 03 5 18359 03 5 18359 03~ 5 18360 03 5 18360 03 5 18359 03 5 18359 03 5 18359 03 5 18360 03 5 18360 04 5 18362 04 95 18364 04 95 18364 04 95 18366 04' 95 18367 04 95 18370 04' 95 18371 04 95 18371 04 95 18372 04 95 18373 04 95 18375 04 95 18375 04 95 18375 04 95 18374 04 95 18374 04 95 18374 04 95 18375 04 95 18376 04 995 18377 04 995 18377 05 995 18380 05 995 18381 05 995 18382 05 995 18383 05 995 18385 05 995 18387 05 /1995 18387 05 /1995 18388 05 995 18388 05 995 18389 05 995 18391 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CAT080020415 DATE GALLONS REMARKS 05 95 18392 05 95 18392 05 95 18393 05 95 18393 05 995 18395 05 995 18397 05 995 18398 05 995 18399 05 995 18400 05 995 18403 05 995 18404 05 /1995 18406 06 995 18407 06 995 18409 06 995 18413 06 995 18415 06 995 18416 06' 995 18417 06 18418 06' ~1995 18421 06 ~1995 18423 06 I1995 18424 06 I1995 18425 06 ~1995 18427 06 5 18429 06~ 5 18430 06 5 18431 06 5 18432 06 5 18433 06 5 18436 06 95 18438 06 95 18439 06 95 18283 06 95 18284 07 95 18289 07 95 18291 07 95 18293 07 95 18294 07 95 18296 07 95 18301 07 95 18303 07 95 18304 07 95 18306 07 995 18307 07 995 18311 07 995 18312 07 995 18313 07 995 18315 Generator Run PROPRIETARY INFORMATION: Not for use or disclosure outside Pacific Bell except under written agreement page 4 FUEL LOGGING REPORT -- NONMETERED TANKS page 5 TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS REMARKS 07 95 18316 07 95 18319 07 95 18320 07 95 18322 07 95 18323 07 95 18324 07 95 18328 08 95 18329 08' 95 18331 08 95 18332 08 5 18333 08 5 18337 08 5 18338 08 5 18340 08 5 18341 08 5 18342 08 5 18344 08 5 18345 08 5 18345 08 5 18346 08 5 18347 08 5 18348 08 5 18349 08 5 18350 08 5 18350 08 5 18351 08 /1995 18353 08 I1995 18353 08 I1995 18353 08 ~1995 18354 09 /1995 18354 09 ~1995 18355 09 ~1995 18355 09 I1995 18356 09 I1995 18191 09 /1995 18191 09' /1995 18192 09 ~1995 18191 09' /1995 18191 09 I1995 18191 09' 995 18191 09 995 18191 09 995 18191 09 18191 09 995 18191 09 995 18191 09 995 18191 09 995 18191 Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING aT -- NONMETERED TANKS TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS REMARKS 09 95 18190 09 95 18190 09 995 18189 10 995 18187 10 995 18186 10 995 18186 10 995 18185 10 995 18184 10 18182 10 18181 10' 18180 10 5 18179 10 5 18178 10 5 18174 10 5 18173 10 5 18172 10 95 18171 10 95 18170 10 95 18167 10 95 18165 10 95 18164 10 95 18163 10 995 18161 10 995 18157 10 995 18155 11 995 18153 11 995 18152 11 995 18150 11 18145 11' /1995 18144 11~ I1995 18142 11 5 18141 11 5 18139 11 5 18135 11 5 18134 11 5 18133 11 95 18132 11 95 18130 11 95 18127 11 95 18126 11 95 18125 11 95 18123 11 95 18122 11 995 18118 11 995 18117 11 995 18116 11 /1995 18114 12 /1995 18113 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement page 6 FUEL LOGGING TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 -- NONMETERED TANKS DATE GALLONS REMARKS 12 995 18108 12 995 18107 12 995 18105 12 995 18104 12 995 18103 12 995 18099 12 18098 12 /1995 18096 12 I1995 18095 12 ~1995 18094 12' ~1995 18089 12 ~1995 18087 12' ~1995 18085 12 5 18083 12 5 18082 12 5 18079 12 5 18075 12 5 18070 12 5 18068 12 5 18067 page 7 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement PACIFIC~;~ BELL ~ A Pacific Telesis Company C. S. Nantze Environmental/Site Manager P. O. Box 601883 Sacramento, Ca 95860-1883 April 11, 1996 Bakersfield City Fire Department Hazardous Materials Division 1715 Chester Ave., Suite 300 Bakersfield, CA 93301 Attention: Ralph Huey, Hazardous Materials Coordinator Attached is Pacific Bell's U e,~~rground Tanks Reconciliation Disclo~r period from January 1, 1996~ough March 31, 1996. the If you have any questions regarding the Tank Monitoring process or the attached reports, please call Jeff Kunz on (916) 972-4379 or Debbie Duplichan on (916) 972-4377. Thank you. C. S. Nantze Environmental/Site Manager (800) 757-6575 CSN:Iu Attachments FUEL LOGGING RE~RT -- NONMETERED TANKS page KERN COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH HAZARDOUS MATERIALS SECTION - UNDERGROUND TANK PROGRAM INVENTORY REPORT 01/01/1996 TO 03/31/1996 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement TANK 288 TANK 289 KERN COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH HAZARDOUS MATERIALS SECTION - - UNDERGROUND TANK PROGRAM INVENTORY RECONCILIATION REPORT 01/01/96 TO 03/31/96 AGENCY TANK ID: ADDRESS: CAD981630411 5650 ALDRIN COURT BAKERSFIELD AGENCY TANK ID: ADDRESS: CAD981630411 5650 ALDRIN COURT BAKERSFIELD FOR THE REPORTING PERIOD OF 01/01/96 TO 03/31/96, I HEREBY CERTIFY THAT DAILY INVENTORY RECONCILIATION RECORDS HAVE SHOWN VALUES WITHIN ALLOWABLE ERROR LIMITS SET BY THE WATER RESOURCES CONTROL BOARD FOR THE ABOVE TANKS. I REALIZE THAT MISREPRESENTATIONS OF DATA ON THIS FORM MAY RESULT IN CIVIL PENALTIES OF UP TO $25,000 PER DAY PER VIOLATION PERSUANT TO SECTION 25819 OF THE CALIFORNIA HEALTH AND SAFETY CODE. NAME: C. S. Nantze SIGNATURE: TITLE: Environmental/Site Manager DATE: 4/12/96 Pacific Bell Fuel Unit 3707 Kings Way, Room B-18 Sacramento, California 95821 PROPRIETARY INFORMATION: Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING R~RT -- NONMETERED TANKS TANK ID : STREET : CITY/STATE: AGENCY ID : 331 1918 M STREET BAKERSFIELD CA CATO80020415 DATE GALLONS 01/01/1996 01/02/1996 01/03/1996 01/04/1996 01/05/1996 01/08/1996 01/09/1996 01/10/1996 01/11/1996 01/12/1996 01/15/1996 01/16/1996 01/17/1996 01/18/1996 01/19/1996 01/22/1996 01/23/1996 01/24/1996 01/25/1996 01/26/1996 01/29/1996 01/30/1996 01/31/1996 02/01/1996 02/02/1996 02/05/1996 02/06/1996 02/07'1996 02/08'1996 02/09'1996 02/12f1996 02/13f1996 02/14f1996 02/15f1996 02/16f1996 02/19f1996 02/20f1996 02/21/1996 02/22~1996 02/23f1996 02/26f1996 02/27f1996 02/28f1996 02/29~1996 03/01f1996 03/04~1996 03/05f1996 03/06~1996 18063 17399 17400 18049 18048 18045 18044 18044 18043 18028 18040 18037 18036 18035 18034 18042 18033 18029 18027 18026 18023 18022 18022 18021 18021 18020 18020 18020 18020 18020 18021 18021 18022 18022 18023 18025 18025 18025 18025 18025 18023 18026 18021 18020 18019 18017 18017 18017 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under REMARKS raised probe,2 probe was dropped use or disclosure written agreement page 2 check segments,see back down ticket FUEL LOGGING R~RT -- NONMETERED TANKS page 3 TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS 03/07/1996 03/08/1996 03/11/1996 03/12/1996 03/13/1996 03/14/1996 03/15/1996 03/18/1996 03/19~1996 03/20~1996 03/21~1996 03/22~1996 03/25 ~1996 03/26~1996 03/27~1996 03/28~1996 03/29~1996 18017 18017 18019 18019 18020 18020 18021 18023 18024 18025 18026 18028 18031 18031 18032 18033 18034 REMARKS PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement Environmemat Managementl P.O. Box 5095, Room 1N200 San Ramon, California 94583-0995 March 29, 1996 .~ ......... ~/~PACIFIC~Y"~ BELL~) City Of Bakersfield Fire Dept-Haz Mat Coord 1715 Chester Ave Bakersfield, CA 93301 RE: Financial Test of Self Insurance (Underground Tanks) The attached is a copy of our Chief Financial Officer Letter to demonstrate financial responsibility for Pacific Bell's underground storage tanks. Also attached, is the annual State of California Water Resources Control Board's Certification of Financial Responsibility form and a list of Pacific Bell sites that have underground storage tanks on the premises in your area of jurisdiction. Please call me on 415-331-0924 if you have questions regarding this correspondence. Nancy Claficy / Environmental Management attachment 3an 8 10:40 lgg6 tank-addr-cllc-geopar~county-gal-product-devlce Page 8 288 5650 ALDRIN CT. BAKERSFIELD, CA 289 5650 ALDRIN CT. BAKERSFIELD, CA 33~l-9-1~8--M--STREET ....... ~ k.~---BAKERSFiELD,.*CA ~ BKFDCA53 SA703 KERN BKFDCA53 SA703 KERN BKFDCA12 SAO04 KERN 11627 UNLEADED 4315 DIESEL2 20000 DIESEL1 333 3221 SO. H STREET BAKERSFIELD, CA 334 3501 COLUHBUS BAKERSFIELD, CA 335 11609 ROSEDALE HWY BAKERSFIELD, CA BKFDCAI4:SA098 KERN BKFDCA13 SA-114 KERN BKFDCA17 SA-224 KERN 5000 DIESEL1 10OO DIESEL1 1000 DIESEL1 990 11101 WHITE LANE BAKERSFIELD, CA BKFDCA19 SA-532 KERN lO00 DIESEL1 337 925 JEFFERSON STREET DELANO, CA DELNCAll SA-149 KERN 1000 DIESEL1 1057 8313 E. SEGRUE ROAD LAHONT, CA 340 2100 BELSHAW AVENUE MOJAVEo CA 1035 1021 CALIFORNIA ST. OILDALE, CA 342 16251 ASKIN DRIVE PINE HOUNTAZN, LEBEC, CA LAMTCAll SA010 KERN HOJVCA01 SA-058 KERN OLDLCAll SA-013 KERN LEBCCA12 SA-322 KERN 1000 DIESEL1 275 WASTE OIL 2000 DIESEL2 500 DIESEL1 P. A. Oafbee and 6ontro,er San Ramon Ca;,forn~a 94583 tSlO1823-85ZQ PACIFIC ~i~BELL A Pacific Teiesis Company March 25,1996 State Water Resources Control Board Division of Clean Water Programs Underground Storage Tank Cleanup Fund 2014 T Street, Suite 130 Sacramemo, CA 95814 Re: Financial Test of Self-Insurance (Underground Tanks) I am the Chief Financial Officer of Pacific Bell, 2600 cammo Ramon, Room 4S001, San Ramon, California, 94583. This letter is m support of the use of the financial test of self-insurance to demonstrate financial responsibility for taking corrective action and/or compensating third parties for bodily injury and property damage caused by sudden accidental releases and/or non-sudden accidental releases m the amount of at least two million dollars annual aggregate arising from underground storage tanks. Underground storage tanks at Pacific Bell facilities are assured by this financial test or a financial test under aa authorized State Program by this owner or operator. A financial test is also used by this owner or operator to demonsuate evidence of financial responsibility in the following amounts under other EPA regulations or State programs authorized by EPA under 40 CFR Parts 271 and 145. EPA Regulations Amount Closxu~ (§§ 264.143 and 265.143) ..................................................................................................... $400,000. Post-Closure Care (§ § 264,145 and 265.145) ...................................................................................... $ 100,000. Liability Coverage (§§ 264.147 and 265.147) .................................................................................... $2,000,000. Corrective Action (§§ 264.101 (b)) ................................................................................................... $100,000. Plugging and Abandonment (§§144.63) ............................................................................................ N/A Closure .............................................................................................................................................. $7,400,000. Post-Closure care ............................................................................................................................... $1,000,000. Liability Coverage ............................................................................................................................. $2,000,000. Corrective Action ............................................................................................................................... $3,700,000. Plugging and Abandonment ............................................................................................................... $150,000. Total .................................................................................................................................................. $16,850,000. This owner or operator has not received an adverse opinion, disclaimer of opinion, or a "going concern" qualification from an independent auditor on his financial statements for the latest completed fiscal year. Alternative ! (Source: Form 10K, December 31, 1995) 1. Amount of annual UST aggregate coverage being assured by a financial test, and/or guarantee .... $2,000,000 2. Amount of corrective action, closure and post-closure care costs, liability coverage, and plugging and abandoarnent costs covered by a financial test, and/or guarantee ................................................ 3. Sum of lines I and 2 ...................................................................................................................... 4. Total tangible assets ....................................................................................................................... 5. Total liabilities (if any of the amount reported on line 3 is included in total liabilities, you may need to deduct that amount from this line and add that amount to line 6) ........................................... 6. Tangible net worth (line 4 minus line 5) ......................................................................................... 7. Is line 6 at least $10 million? ......................................................................................................... $. Is line 6 at least 10 times line 3? 9. Have financial statements for the latest fiscal year been filed with the Securities and Exchange Commission? .................................................................................................................................... Yes 10. Have financial statements for the latest fiscal year been filed with the Energy Information Administration? ................................................................................................................................. N/A 1 !. Have financial statements for the latest fiscal year been filed with the Rural Elecwician Administration? ................................................................................................................................. N/A 12. Has financial information been provided to Dun and Bradstreet and has Dun and Bradstreet provided a financial strength rating ora 4A or (answer "yes" only if both criteria have been met) ............................................................................. Yes I hereby certify that the wording of this letter is identical to the wording specified in 40 CRY pan 280.95 (d) as such regulations were constituted on the date shown immediately below. Sincerely, $16,850,000. $18,850,000. $13,$99,000,000. $10,788,000,000. $3,111,000,000. Yes Yes Peter A. Darbee Vice President, Chief Financial Officer, and Controller Pacific Bell State Water Resources Control Board CERTIFICATION OF FINANCIAL RESPONSIBILilY FOR UNDERGROUND STORAGE TANKS CONTAINING PETROLEUM A. I am required to demonsU'ate Financial Responsibility in the required amounts as specified in Section 2~07, Chapter 18, Div. 3, Title 23, CCR: ~'~ 500,000 dollars per occurrence [~ 1 million dollars annual aggregate or AND or ~-~ 1 million dollars per occurrence ~ 2 million dollars annual a$~egate Nancy Clancy of Pacific Bell Article 3, Chapter 18, Division 3, 7'~tle 23, California Code of Regulations. The mechanisms used to dernonstmte financial responsibility as required by Section 2807 are as follows: Name and Address of Issuer Pacific Bell Environmental Management 2600 Camino Eamon,T~t 1N200 San Ramon, CA 94583 hereby certifies that it is in compliance with the requirements of Section 2807, . Mechanism ::::' · · · :NUmber. ........ ~,overage..... ':".:~. ': :'Amount $16. 850;000 · Coverage · Period Renewed Annually ~. Mechanism.:.. Type Chief Financial Officer Letter (Attached) Corrective Action Yes ,our execution and submisston Not Applicable For State Alternative Mechanism Note: If you are using the State Fund as any part of your demonstration of financial responsibility, of this certification also certifies that you are in compliance with all conditions for participation in the Fund. Third Party Comp.:, Yes ~. J:~t~ N~me F~t Name Fa~:ifi~ Name Pacific Bell See Attached List F~li~,~,~ Fncili~ ~ciress INSTRU_______CTIONS CERTIFICATION OF FINANCIAL RESPONSIBILITY FORM PLease type or print cLearLy aLL information on Certification of Financial ResponsibiLity fora. ALL UST facilities and/or sites ounad or operated may be Listed on one fora; therefore a separate certificate is not required for ea~, site. DOCUNENT %NF~h;T %ON A. ~t Required - B. Name of Ta~k O~ner - or Operator C. Nechanism Type - NME of issuer #echanism #m~3er Cover~J~ao~lqto Coverage Period - Corrective Action - Third Party - D. FaciLity - Information E. Signature BLock - Check the al~oropriate bexes. Full name of either the tank owner or the operator. Indicate ~hich State approved mechanism(s) are being used to show financial responsibility either as contair~,d in the federal regulations, 40 CFR, Part 280, subpart H, Sections 280.90 through 280.10] (See Financ(~L RponsibiLity Guide, for mere inforaation), or Section 2802.1, Chapter 18, Oivision 3, Title 2], CCR. List all names and addresses of coa~oanies and/or indi%i'duaLs issuing coverage. List identifying nunloer for each mechanism used. Exan~3Le: insurance po[icy nu'aber or file n~mber as indicated on bend or docta~ent. (If using State CLearaA3 Fur~t (State Fund) Leave blank.) Indicate amount of coverage for each type of mechanism(s). If mere than one mechanism is indicated, total must equal IOOX of financial responsibility for each facility. Indicate the effective date(s) of all financial mechanism(s). (State Fund coverage would be continuous as Long ss you maintain compliance and remain eligible to continue participation in the Furct.) Indicate yes or no. Does the specified financial mechanism provide coverage for corrective action? (If using State Fund, indicate "yes".) Indicate yes or no. Does the specified financial mechanism provide coverage for third part~ .:~pensation? (if using State Fund, indicate "yes".) Provide ail facility and/or site names and addresses. Provide signature and date signed by tank owner or operator; printed or typed name and title of tank owner or operator; signature of witness or notary and date signed: and printed or typed name of witness or notary (if notary signs as witness, please place notary seal next to notary's signature). t~nere to Nail Certification: PLease sencl original to your Local agency (agency who issues your UST permits). certification at each facility or site Listed on the form. ~eep a copy of the If you have questions on financial responsibility requirements or on the Certification of Financial Responsibility Form, please contact the State UST Cleanup Fund at (916) 7'59-2&75. Note: penalties for Failure to ~-~.t¥ with Financial Responsibility Requirements: Failure to comply may result in: (1) jeopardizing claimant eligibility for the SLate UST CLeanup Fu~cl, and (2) Liability for civil penalties of up to S10,000 dollars per day, per underground storage tank, for each day of violation as stated in Article ?, Section 25299.76(a) of the California Health and Safety Code. PERMIT No. Bakersfield Fire Dept SERVICES OFFICE OF ENVIRONMENTAL PROGRA----- UNDER ROUN STO. E ta.K PERMIT APPUCATION TO CONSTRUCT/I~_ODIFY UNDERGROUND STORAGE TANK TYPE OF APPLICATION_ (CHECiO [] NEW FACTLITY J;B:{'MODIFIl~'Al'ION OF FACILITY Q NEW TANK INSTALLATION AT EXISTING FACILITY STARTING DATE ~..~- ,,~%-' %-" fill PROPOSED COMPLE11ON DATE .~: .m~-- ~ FACILITY NAME ~F. tP~ 't~_~J_J - EXISTING FACILITY PERMIT No. FACILITY ADDRESS I =1%~, ' .I/,.~ ~-~----,,e~,?:..~'A"'_; ~--~L=~: ¢J~ ZiP CODE 1YPE OF BUSINESS L,""T1 J...t'T"l' 0 __~q,,luz~.~,~'~ APN TANK OWNER '"~=,,NC.tt~.I~L, h~..~_J ~_- I- PHONE No. ADDRESS_d',_,~a~,~ ~_~[ J~vcxtu,"-, ~. ~-OI CI~~ ~P CODE CONTRACTOR ~ ~[ ~~~ CA LICENSE No. ADD~ESS CI~ ZIP CODE PHONE NO. BAKERSFIELD ~ BUSINESS LICENSE No. WORKMAN COMP. No. INSURE~ BREIFLY DESCRIBElHE WORK TO BE DON~ ~v~ I ~t~m]- ~; WATER TO FACILITY PROVIDED BY' DEPTH TO GROUND WATER /~-'~-- No- OF TANKS TO BE INSTALLED ~14~... ~ _ $O1L TYPE EXPECTED,~-T'SiTE ARE THEY FOR MOTOR FUEL 'J:~'YES Q NO SECTION FOR MOTOR FUEL TANK NO. VOLUME UNLEADED REGULAR PREMIUM DIESEL AVIATION SECT1ON FOR NON MOTOR FUELSTORAGE TANKS TANK No. VOLUME CHEMICAL STORED CAS No. (no Dronct nome) (if known) CHEMICAL PREVIOUSLY STORED THE APPLICANT HAS RECElVEO. UNOERSTANO$. AND WILt. COMPLY WITH THE ATTACHED CONDITIONS OF THIS PEr[MIT AND ANY OTHER STATE. LOCAL ANO F~OEi~AL REGULATIONS- THIS FO'~M HA5 BEEN COMPLETED UNDER PENAL~ O~ P~URY. AND TO THE BEST CF MY KNOWLEDG~ IS T~U~ ANO COrreCT. THIS APPLICATION BECOMES A PERMIT WHEN APPROVED Auto Tire Rebldg. Plants Auto Wrecking Junk Yard ~laSte H~ld ling Boeling Alley Cellulose Nitrate Combustible Pibres Dnst Explosion Misc. Ammunition Flammable Finishes Spray Finishes Flammable Liquids Fumigation Gar~a Hazardous Chem. Liquefied Pat Gas Lumbe~ Yard Magnesium Hatches Place of Assembly Tent Welding & cutting Motion Plo Project Airport-He 1 iport Organic Coating High Piled Stock Extin. System Smoke ivac. .~¥atem This card is to remain in a conspicious place near the installation until final inspection is made and approved. Remarks; Final Inspection: .19 Inspector: BAKERSFIELD FIRE DEPARTMENT \- AFFLICTION ~lim No. In conformity wi~h provisions of [x~rtlr~nt ordinances, codes and/or regulQ~ions, al~licotim is made by: to display, ~om, i~ll, ~, ~mte, ~11 or ~ndle ~tcri~ls or pr~e~ in~l~in9 or crying (~- diti~s ~d ha~r~ ~ lite or prc~ as foll~s:  ,:/~' /Authorized Repras~ive ] Permit denied Dam . '~ O~E OF ENVIRONMENTAL~RVICES "~" UNDERGROUND STORAGE TANK PROGR~ ~_ ~,~ 1 .L~_7 PERMIT APPUCATION FOR REMOVAL OF AN UNDERGROUND STORAGE TANK SITE INr-OIIMA1]_O_N SiTE -ji;~j~..tpte_. ~. ADDRESS ICll,~')~ ~.~~P CODE ?~g2J APN FACIL~-I~NAME :~l~.t~t _e_, ~ CROSS STREET ,,~D-P,~ ~ TANK OWNERIO~-ERATOR ~~, I~L., PHONE No. MAIUNG AODRESS~,,-~_ H~.~.Ln.~,t A'~P..-; ~ I~-- DJ _ OIlY ~ ZiP CODE CONTEACTOR INFORMATI_O_N_ COMPANY ADDRESS PHONE No. INSURANCE CARRIER LICENSE No. CIIY ziP CODE WORKMENS COMP No. PREI. IMANARY ASSEMENT INFORMATION COMPANY ADDRESS PHONE No. INSURANCE CARRIER LICENSE NO, CIIY ZiP CODE WORKMEN$ COMP No. TANK CLEANING INFORMATION COMPANY ADDRESS WASTE TRANSPORTER IDENTIFICATION NUMBER NAME OF RINS"'rATE DISPOSAL FACILITY ADDRESS FACILITY INDENTIFICATION NUMBER PHONE NO. CITY ZIP CODE CITY ZIP CODE TANK TRANSPORTER INFORMATION COMPANY ~. :_~- C:~I~?,4~-t~ PHONE No. ADDRESS TANK DEST1NAI'ION LICENSE No. CiTY ZIP CODE TANK INFORMATION TANK No. AGE VOLUME CHEMICAL DATES CHEMICAL STORED STORED PREVIOUSLY STORED ......,::,:...~:.::. `~::~>~`.~:~"~-:;:~.;~2~TXT~:~.~.~:~:~:~::g:::L~::~:`:: ............. : ............ ~:.,.~,,~.~.~:~:~:~:~;-3~:~:~:,.~.~:;.. :.. ~. - ~. ..~ ..:~,~,.~-~x:. :~;: , ..:. ............................................... : .... ...:... ~:.:~.;~::~ :~ ~-' ~.: ............. , .......... ., · ........ .,~...~,:,: :: ~ ............ ~ . . _,..:~.~.:[~y ................................ ......... - -AT ......... , ........ ? ............... ,?.:,..FACt~N~ ..... c ............................. ,~ .~ .... ~ .... . ........ ~ . ~e ~u~A~L~.~:~.......e~:- ........ ~ ......................... :, :,.:,.,,:- ..................... ~::~:~.-: ::~:.~ .......... ~ .~...,... ............ : ~., ,..~.~~~-----~ ............................. T,~:.c:,~:~:~,2~,:~;:,~:;~::;:;~::~y~:;~:'.:~ ............. :-;;: ........ ;.:.~-::-: :~:,,:~.: .~: ................. ~::? .............. ...,. , ............ ........... THE APPLICANT HAS RECEIVED. UNDERSTANDS. AND WILL COMPLY WT~ THE A~ACN EO CONDItiONS OF THIS PERMIT ANO ANY OTHER STATE. LOCAL AND FEDERAL REGULATIONS, THIS FORM HAS BEEN COMPLIED UND ER PENAL~ O~ PENURY. AND TO T~E 5EST OF MY KNOWLEDB~ LS TRUE ANO CORRECT. APPL1CA~TNAME (~nINB [ ~PLICA~'SIGNATURE THIS APPLICATION BECOMES A PERMIT.WHEN APpR__~OVEO- ..... ,- ,..., ,~_,.-,,~c, ,-,^v^c~l ,- ~n T~ -pi'tv hi:: R&KI::I:I~FIi=LD' Shie] , Harper & Co. ElectronicO~ervice slo? aro~=~z ' ~iV~OOCT 2 ? 19~5 Oakland, CA 94611 (800) 772-3208 MONITORING SYSTEMS INSPECTION FORM CONSOLE ALARM SIMULATION TEST PASS~FAiLED YPE: LOCATION: LOCATION: PROBE/SENSOR TEST PASS~/FAILED TEST PASS FAILED ITYPE: LOCATION: PROBE/SENSOR TEST PASS FAJT,FD j PE: LOCATION: PROBE/SLNSOR TEST PASS FAILED JTYPE: LOCATION: PROBE/SENSOR TEST PASS FAILED__ ITYPE: LOCATION: PROBE/SENSOR TEST PASS FAILED__I ITYPE: LOCATION: PROBE/SENSOR TEST PASS FAILED__I TYPE: LOCATION: PROBE/SENSOR TEST PASS FAILED__I TYPE: LOCATION: PROBE/SENSOR TEST PASS FAILED__1 ITYPE: LOCATION: PROBE/SENSOR TEST PASS FAILED COMMENTS M 337 3/27/9! L J___!__ !' I-'"1 I! R.E. HUEY HAZ-MAT COORDINATOR (805) 326-3979 CITY of BAKERSFIELD FIRE DEPARTMENT FIRE SAFETY SERVICES & OFFICE OF ENVIRONMENTAL SERVICES 1715 CHESTER AVE. · BAKERSFIELD, CA · 93301 September 15, 1995 R.B. TOBIAS, FIRE MARSHAL (805) 326-3951 PACIFIC BELL 2175 N CALIFORNIA BLVD. #625 WALNUT CREEK, CA 94596 Dear Business Owner: BAKERSFIELD CITY LOCATIONS NOTICE OF VIOLATION STATE REGISTRATION REQUIREMENT Failure to renew your state registration is a violation of Section 25287, California Health and Safety Code, and will result in your Permit to Operate the underground tank(s) being revoked. Owners of underground storage tanks must register those underground storage tanks with the State of California Water Resources Control Board and renew that registration every five years. Our records indicate five years have passed since your last State registration pursuant to Section 25287 of the California Health and Safety Code. This means that for state registration renewal you must submit a state'surcharge of $56.00 for each tank. Please make your check payable to the City of Bakersfield. You have 30 days from the date of this letter to return the state surcharge to 1715 Chester Ave., Bakersfield, Ca. 93301. If you have any questions or if we can be of any further assistance please don't hesitate to call 326-3979. RE: 1918 M ST 3221S H ST 3501 COLUMBUS 11101 WHITE LN 5650 ALDRIN CT Sincerely Yours, Ralph E. Huey Hazardous Materials Coordinator REH/ed BAKERSFIELD FIRE DEPARTMenT HAZARDOUS MATERIAL DIVISION 1715 CHESTER AVE., BAKERSFIELD, CA (805) 326-3979 93304 APPLICATION TO PERFORM A TIGHTNESS TEST FACILITY~ ADDRESS PERMIT TO OPERATE ~ NUMBER OF TANKS TO BE TESTED / TANK~ VOLUME OWNERS NAME__~2~~- IS PIPING GOING TO' BE TESTED _CONTENTS TEST 'METHOD NmE Or TESTER~_D_~=.',Z. CERTIfiCATION ~ STATE REGISTRATION ~ DATE ~,. SIGNATURE OF AP~PL~I ANT 41 ate Underground Hazardous Materials Storage Facility State I.D. No. CONDIT Tank Hazardous Number Substance Issued By: IONS ~!!iii,::P:~!~!i~ i;~!~EVE. RSE SIDE G~ii::~?~%?? ..... Y.e.:a~:,ii'~ii~,,:. ::: !;.~Tank '~::~:;:i;i~,~iii:i;i':i!:'i::!i!!i! P,p,ng Piping C ~1~:a.6!{~'%-!:;?:' I n'~'{~:Ji~ a:?;-'::::., ii :i::'.?T y p e U o h'! { 67~::::/::::~':~::?~;: Type Method HAZARDOUS MATERIALS DIVISION 1715 Chester Ave., 3rd Floor I~t~ ~ .~T Bakersfield, CA 93301 ~,k~.Cd. o~ (805) 326-3979 Piping Monitoring ~-~ Approved by: Ralph E. Huey, Hazardous Materials Coordinator Valid from: ',),' ~ '~ '~'~ to: Environmental Mana~ent 2600 Camino Ramon, Room 2E150 San Ramon, CA 94583 PACIFIC ~IBELL A Pacific Telesis Company February 24, 1995 City of Bakersfield Mr. Ralph E. Huey Hazardous Materials Coordinator Bakersfield City Fire Department 2130 G Street Bakersfield, CA 93301 Mr. Huey: Attached is the annual State of California Water Resources Control Board's Certification of Financial Responsibility form which I have completed along with a copy of our Chief Financial Officer Letter. Also included is a list of Pacific Bell sites that have underground storage tanks on the premises within your jurisdiction. If you have any questions please call me on 916-972-4229. Klm Melville Environmental Management State of Califomh Stat~ Water Resources Control Board CERTIFICATION OF FINANCIAL RESPONSIBILITY FOR UNDERGROUND STORAGE TANKS CONTAINING PETROLEUM I am required to demoastra~ Finaneial Responsib{fi~ in {he ~iuired amoun~ as specified in Section 280~, Chapter 18, Div. ~, Title 23, CCR: ~ 500,000 dolhrs per o~c~frence ~ t million dollars annual aggregate or ,M~D or .~1 per o~eun'eaee ~] 2 million dollars annaai aggregate dollars Chief Financial Offic~ Lcuer (attached) Pacific Bell Envimnmcnta! Management 2600 Camino Ramon i Room 2E150 San Ramon, CA 94583 hereby certifies that it is in compliance with the requirements of ,~c, tion 2807. 16,850,000. Renewed ' Annually Not applicable for State' Alternative Mechanism Note: If you are using the State Fund as any part of your dernonstc~tion of financial responsibility, your execution and submission of this cer~lcation also certifies that you are in compliance with all conditions for participation in the Fund. D. Facillty Name Fa6lity N~a~e PACIFIC BELL Facili~ Fatality Name FadIity/~ddr~s Fa61ity Name Facility Addre.~ Facility Name Fadll o/Addr~.s E. S{~amre~fTtmk Owns-or Opea'a~ ~o~ ;' ~- L_,/ Date [ Na~me and Tide of Tank Owue~ m' Operator ..*Sits~ C~tv: Site Address: Bakersfield 101 "V" St. Bakersfield I 1101 White Lane Bakersfield 11609 Rosedale Hwy Bakersfield 148 Weed Patch Hwy. ~t. Woods, Dennis Woods, Dennis Woods, Dennis Bakersfield--~ ......... 191.7..2LXT~ St ................... unknown Bakersfield 1918 M Street "- Woods, Dennis Bak~-s~ld----- ~2a~20-L St. - - ----vacated Bakersfield 3221 S. "H" St.' Woods, Dennis Bakersfield 3501 Columbus -' Woods, Dennis · -~rff-- .... 5IO1-Office-P~k Address: 101 "V" St., Bakersfiled 3221 S. H Bakersfield 3221 S. H Bakersfield 3221 S. H Bakersfield -----Schmidt-,-Eric- 805-327-6567 St., Rm. 101, 805-398-4648 St., Rm. 101, 805-398-4648 St., Rm. 101, 805-398-4648 3221 S. H St., Rm. 101, 805-398-4648 Bakersfield Bakersfield Bakersfield 3221 S. H St., Rm. 101, 805-398-4648 Bakersfield 3221 S. H St., Rm. 101, 805-398-4648 Bakersfield 5101-OfficePart~r ....... 805-327-661M Bakersfield 5650 Aldrin Ct. Matthews, Dennis Maricopa Hwy. & Old Hwy. Woods, Dennis 5650 Aldrin Ct., 805-398-4404 Bakersfield 3221 S. H St., Rm. 101, 805-398-4648 Bakersfield North Region North Region North Region North Region ..... -Vacated ..... Unknown North Region .... Vacated_L-, North Region North Region Nor~th---Reg ion~ North Region North Region PROPRIETARY INFORMATION Not for use or disclosure outside Pacific Bell Except under written agreement ii- Januaw 24,1995 ~. ~ _ PAC I FI ~. e'.~ B ELL ~ A Pacific Telesis Company State Water Resources Control Board Division of Clean Water Programs Underground Storage Tank Cleanup Fund 2014 T Street, Suite 130 Sacramento, CA 95814 Re: Financial Test of Self-Insurance (Underground Tanks) I am the Chief Financial Officer of Pacific Bell, 2600 Camino Ramon, Room 4CN100, San Ramon, California, 94583. This letter is in support of the use of the financial test of self-insurance to demonstrate f'mancial responsibility for taking corrective action and/or compensating third parties for bodily injury and property damage caused by sudden accidental releases and/or non-sudden accidental releases in the amount of at least two million dollars annual aggregate arising from operating underground storage tanks. Underground storage tanks at Pacific Bell facilities are assured by this financial test or a financial test under an authorized State program by this owner or operator. A financial test is also used by this owner or operator to demonstrate evidence of financial responsibility in the following amounts under other EPA regulations or State programs authorized by EPA under 40 CFR Parts 271 and 145: EPA Regulations Amount Cl6sure (§§ 264.143 and 265.143) ................................................................................... $400,000. Post-Closure Care (§§ 264.145 and 265.145) ................................................................. $100,000. Liability Coverage (§§ 264.147 and 265.147) ............................................................... $2,000,000. Corrective Action (§§ 264.101 (b)) ................................................................................. $100,000. Plugging and Abandonment (§§ 144.63) ....................................................... ~ ........................... N/A Closure ............................................................................................................................ $7,400,000. Post-Closure Care .......................................................................................................... $1,000,000. Liability Coverage ................................................................. ~ ........................................ $2,000,000. Corrective Action ........................................................................................................... $3,700,000. Plugging and Abandonment .............................................................................................. $150,000. Total .............................................................................................................................. $16,850,000. This owner or operator has not received an adverse opinion, a disclaimer of opinion, or a "going concern" qualification from an independent auditor on his financial statements for the latest completed fiscal year. Alternative I (Source: Form 10K, December 31, 1992) 1. Amount of annual UST aggregate coverage being assured by a financial test, and/or guarantee ................................................................... $2,000,000. o Amount of corrective action, closure and post-closure care costs, liability coverage, and plugging and abandonment costs covered by a financial test, and/or guarantee ......................................................... $16,850,000. Sum of lines 1 and 2 ................................................................................... $18,850,000. Total tangible assets .......................................................................... $19,378,000,000. Total liabilities (if any of the amount reported on line 3 is included in total liabilities, you may deduct that amount from this line and add that amount to line 6) ................................................................... $13,224,000,000. 6. Tangible net worth (line 4 minus line 5) .............................................. $6,154,000,000. 7. Is line 6 at least $10 million? ................................................................................... Yes 8. Is line 6 at least 10 times line 3? ............................................................................. Yes 9. Have financial statements for the latest fiscal year been filed with the Securities and Exchange Commission? .................................................................. Yes 10. Have financial statements for the latest fiscal year been filed with the Energy Information Administration? ....................................................................... N/A 11. Have financial statements for the latest fiscal year been filed with the Rural Electrification Administration? ...................................................................... N/A 12. Has financial information been provided to Dun and Bradstreet and has Dun and Bradstreet provided a financial strength rating ora 4A or 5A? (answer "Yes" only if both criteria have been met) .............................................. Yes I hereby certify that the wording of this letter is identical to the wording specified in 40 CFR Part 280.95 (d) as such regulations were constituted on the date shown immediately below. Peter A. Darbee Chief Financial Officer Pacific Bell Date January 24, 1995 2 FROM SACTO FLEET ADMIN CENTER TO 180532605?6 P.01 PACIFIC BELL ESEP Environmental Mgmt., Safety, & Emergency Preparedness FAX NO: 91.6486-9087 i DATA TRANSMnTAL COMPANY: FAX NO: FROM: DATE: , ..PHONE; 916-972-4229 THIS TRAN$31ITTAL CONS[ST OF E} PAGES, INCLUDING TI-IIS COVER SHEET. IF TOTAL NUMBER OF PAGES ARE NOT RECEIVED OR NOT LEGIBLE, PLEASE C3 LL 916-972-4229 ~R RETRANSMISSION. ~The information contained in this facsimile message may be co~.~nt, proprietary and/or legally privileged information intzaded on/y/or the use of the/nd/v~,,-~ or epa ~nj named above. If tl~e reader of this message is not the intended recipient, you are hereby notified that any copying, dissemination or distribution of confulential, proprietary or privileged information is stt~-tIy prohibited. If you have received this communication trt error, please immediately not~-y the sender by teleph~rte, and we will artmlge for the return of the facsimile. Thank ~o~. . ~ BAKERSFIELD FIRE DEPARTMENT 0460 Sub Dlv.~ Z)t~ ...... T..,ot_ .......... ¥Otl are hereby req~ed to make the fo~o~ng corrections at the above MRR-08-1995 10:13 FROM SACTO FLEET ADMIN CENTER TO 180532605?6 P.03 UNDERGROUND STORAGE TANK INSRECTtON Bakersfield Fire Dep~ Bek~s~dd~ ~ 93301 MAR-08-1995 10:13 FROM SACTO FLEET ADMIN CENTER TO VEEDER-ROOT 'REMOTE SYSTEM RECERTIFICATION INSTRUCTIONS 180532605?6 P.04 Ii.~ued ~Y2 Remote System Recertification for TLS-250 & TLS-250i ' Consoles This procedure is to b~ used to determine that the 'l'I_5 system is operating properly. The TLS diagnostics implemented by this procedure can check system and probe operation, check last leak test results, and print inventory reports., I~ cannot detect any ~echanical p~blems such as display segments out, printer ma:'Ifunctions or sump sensor problems. Function Frequency Procedure __ Run System Diagnostic Check _,Yearly Follow instructions outlined ~n Procedure 1. Print Inventory R?ort. Yearly Follow instructions outlined in Procedure 2. Run Diagnostic Check on Probes to Yearly Follow iltstructions ou~U~ed ia Proc~ciure 3. detect ope,~ or shorted segmenls. , ....... : Checl( [~st Leak Test Result to verify As required by s~ate and Follow irtstructioru$ outlined in Procedure 4. tanks have passed. ,., local regulatio~ MAR-OS-ID95 PROCIgDURI~ t. 10:14 FROM SACTO FLEET ADMIN CENTER TO 180532605?6 P.05 o t-,l IVl I" LI=' Perform thc foUowiag proccdur~ to verify that the monitor passes Se 'Diagnostic Check. It it tails this test, a service call should be made to correct thc problem. 001 Cold start (Reset) <SOH>O01 Function Code: Function: Command F~rm~l: Typical Response Message: < SOH> 0019FF35 <ETX> Function Code: Function: Command Format: Typical Response Message: PROC£DURE 2. Function Code: Function: Command Format: Typical Response Message: Follow this 970 Serf Diagnostic Results <SOH>970 97O VO RAM PROM MAIN BOARD PASS PASS PASS OPTION BOARD PASS' PASS PASS procedure m print an iavemory report and verify its accu~cy wiu't the location. 20T : Inventory Report : <SOH>20T (T = tank number 1 - 8, 0 = all activ:e or cbnfigured tan~) 200 VEEDER-ROOT ' TLS-250' TANK LEVEL SENSOR FEB 1, 1992 4:38 PM TANK PRODUCT GALLONS INCHES WATER 1 REGULAR UNLEADED 7930 64.52 0.0 2 DIESEL FUEL 7775 63.38 0.0 (up to eight tanks) OEG F ULLAGE 76.9 2450 78.0 2605 PROCEDURI~ 3. Function Code: Function: Command Format: Typical Response Message: TANK 1 1355.32 TANK 2 1346.95 Use this procedure to print probe capadtanc~ values. Check for any Shorted or open segmcnrs. 94T Standard Capacitance Data <SOH>94T (T = tank number 1 - 8, 0 = all active or Configured tanks) 94O UNLEADED REGULAR 1285.54 2471.52 2452.58 DIESEL FUEL 1298,23 2469~52 2463.19 NUMBER OF SAMPLES = 49 2480.21 2547,75 1513.78 1521.89298.19 1435.62 NUMBER OF SAMPLES = 46 , 2439.56 2351.75 1481.60 1518.56 286.30 1411.12 (up tO eight tanks) MAR-08-1995 10:14 FROM SACTO FLEET ADMIN CENTER TO 180532605?6 P. 06 RR/i I""'LI= PROCEDURE 4. Fun:tion: Command Format: 'Typical R~ponse Me~age: 210 LEAK MONITOR REPORT . TEST START: 3:31 'PM TEST STATUS: OFF Use this procedure to print the Last l~k Test Report. : 21T In-Tank Leak Report <SOH>21T O' = tank number 1 - 8, 0 = all active or c~nligured tanks) FEB17,1992 TANK 1 UNLEADED REGULAR 02 GALLON/HOUR TEST FAILED START TEMP: 79.6 DEG F START VOLUME: 6787 GALLONS ENDING TEMP: 79.60EG F LEAK RATE: 6.39 GALLONS/HOUR CUMULATIVE HOURLY VOLUME CHNqGE (GALLONS): 0.0 0.0 8.7 8.78.7 16.2 1'6.2 16.2 40.2 402. 47.3 47.3 55,7 62.7 70,4 70.4 78.6 78.6 85.3 85,3 85,3 92.0 99.9 TANK :2 DIESEL FUEL 0.2 GALLON/FlOUR TEST PASSED START TEMP: 80.6 DEG F START VOLUME: 8464 GALLONS ENDING TEMP: 80.5 DEG F .LEAK RATE: 0.12 GALLONS/HOUR CUMULATIVE HOURLY VOLUME CHANGE (GALLONS): 0.0 0.0 0.2 0.2Q.2 0.6 0.6 0.6 1.1 1.1 1.1 1.1 1.3 1.3 1.6 1.6 1.6 1.6 1,8 1.8 1.8 .1.8 2.8 (up to eight tanks) MAR-08-1995 10:14 FROM SACTO FLEET ADMIN CENTER .Feb '2 15:3I 1995 REcE~T~CATION P~g~ 23T TO 18053260576 P.07 331 KERN BAKERSFIELD CA SWiTCHIN~ BEFDCA12 -$180563125h0.i 331 KERN B~KZRSFIELD CA SWITCHING BKFDCA12 0019FF35 9?0 I/O RAM PROM MAIN BOARD PASS PASS PaSS OPTION BOARD PASS PASS PASS 2OO PACIFIC BELL BKFDll 1918 M STREET, BAKERSFIELD CA 93301 JAN 28, 1995 10:1T ~ TANK PRODUCT 1 DIESEL GALLONS INCHES WATE~ 183~6 lO2.9~ o.o DEG F ULLAGE 65.9 1~6i 9~o TANK 1 DIESEL Nl3MBER OF S~PLES = 6h 5?95.656 7256.172 lq669.~20 1~26.660 i5o28.190 ~h861.870 1~8q3!.080 lhST6.TSo 1~969.o90 13057.520 993o.o~T 8521.375 3691.~37 3523.516 3926i. o62 351~.9o6 3~97-o00 3511.953 3858.375 ~9~9.609 210 LEAK MONITOR REPORT TEST START: 12:00 AM TEST STATUS: ON JAN 27, 1995 TANK 1 DIESEL 0.20 GALLON/HOUE TEST PASSED START TEMP: 66.1 DEG F START VOLUME: 18396 ~ALLONS ENDING TEMP: 66.0 DEG F LEAK RATE: -0.03 GALLONS/~OUR CUMULATIVE HOURLY VOLUME CKA/~GE (GALLONS): -0.0 -0.0 -0.1 -O.Z -0.2 -0.~ -0.3 -0.3 -0.~, -0.~, -0.~ -0.6 -o.6 -0.6 -0.6 -0.6 -0.6 -0.6 -0.6 -0.6 -o.? -o.? -o.8 -!killphone 180563125~0'. MAR-08-1995 TEST DATE: 10:15 FROM SRCTO FLEET RDMIN CENTER TO 180532605?6 P.08 CERTIFICATE OF UNDERGRO_UND STORAGE TANK SYSTEM TESTING NDE ENVIRONMENTAL CORPORATION 8906 WALL STREET, SUITE 306 AUSTIN, TEXAS 78754 (512) 719-4633 FAX (512) 719-4986 TEST RESULT SITE SUMMARY REPORT TESTTYPE: a~e=~ 1000 October 2&, 199& NDE WORK ORDER NUMBER: 914~09 CLIEN'E. P~3ZFZC 6801 3J.~AD~ ~D ~ JOS~e, CA 95120 ATTN: T,I~ SITE: P~3ZFZC ~L~ 1918"M' ;?P,,E~'/' B~RS~Z~D,i CA 93301 The following tests were conducted at the site above in accordance with all applicable portions of Federal, NFPA and local regulations. Tank Tests , ,~f , .' ~, ~ . . ~~~~ ,~g~.... . . ,. :, DZZ~T- 20 · 000 119.00 0.008 Line and Leak Detector Tests NDE Customer Service Representative: Reviewed: NDE appreciates ~e oppodunity to serve you, and looks for~'ard to working wi~h you in the future. Please call a~y time, day or night, when you need us. Test conducted by: HENSL~Y BAR~O~I Techniciah/C~~mb~ er: MAR-08-199S 10:16 FROM SACTO FLEET ADMIN CENTER TO 180532605?6 P.09 ~ . INDIVID~ LINE/LEAK_ DETECTOR IT REPORT J~I~E - NDE ENVIRONMENTAL CORPORATION TEST DATE: 0¢~ 24, ~99& WO~KORDER NUMBER; 9Z~009 CLIEnt ~IFZ~ ~ SITE: PACIFZ~ BELL Tank ID; zxl Bottom to top fill in inches: ~,s2 .o Product; oz]~szz, Bottom to grade film in inches: 24?. o ~pacity in galbns: ~o, 00o Fill pipe length in inches: ~. o Diameter in in.es; zz~. oo Fill pipe diameter in inches: 4.0 Leng~,~ in.es: 41g Stage I vapor recove~ry: ~ Material: ffza~g~s Stage II vapor re¢ove,~: ~ Tan~ ~o M~ifolde~ Ven~ ~ V~: NO ~ ........................... ; , , ..: ~' ~ :~ ....... ~ ~ :.,..~. Test method: Ale~ Logo Psi at tank bottom: Fluid level in inches: Xos.s0 U ET/OF'E, UL~ Fluid volume in gallons: lB, .09 Water level in inches: o. 00 Test time: 09=43-14= 07 Number of thermisters: Specific gravity: o. 850 Water table depth in inches: Determined by (method): sm~v~ Leak rate in gph: o. oas RESULT.' ~s Test method: Test time: Ullage volume: Ullage pressure: RESULT: OATA FOR UTS-~T ONLY: Time of test 1: Temperature: Flow rate (cfh): Time of test 2: Temperature: Flow rate (cfh): 'lqme of test :3; Temperature: Flow rate (ct'h): DEVXC~. New/pas ,~ed Failed/replaced detector i detector Test method: ~A Make: : Model: Open time in sec: Holding psi: Resiliency cc: Test leak rate mi/mint Metering psi: Calib. leak in gph: RESULT: Material: s~sz~. Diameter (in): ;t. o 2. o. Length (ft): Test psi: Bleeclback cc: Test time (rain): Test 1: start tlrnm finish psi: vol change cc: Test 2: start time: ~1 ohange ~: Test 3: staff time: finish pek ~t c~age c~: Final gph: RESULT: Test type: Pump type: ]~sso3~ Pump m~ke: ~ANK ~AS TWO w0-,,-~'r~'E~, WITH NO ~ ~E~TO~.NO 8906 WALL STREET SUITE 306, AUSTINt TEXAS 71~754 IS MRR-08-1995 10:17 FROM SACTO FLEET ADMIN CENTER TO SITE O!AGRAM, 180532605?6 P. 10 NDE ENVIRONMENTAL CORPORATION 8906 WALL STREET, SUITE 306 AUSTIN, TEXAS 78754 (512) 719-4633 FAX (512) 719-4986 TESTDATE: Oct,ober 24, 1994 CUENT: PACIFIC B~LL WORK OR~ER NUMBER: 914009 SITE: PACIFIC B~LL PACIFIC BELL 1918 M ST. BAKERSFIELD,CA 93301 W/O #914009 10/24/94 FUEL LOGGING R~ -- NONMETERED TANKS TANK ID :331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS REMARKS 01 4 19381 01 4 19380 01 94 19378 01 94 19377 01 94 19375 01 94 19371 01 994 19370 01 994 19370 01 994 19369 01 994 19367 01' 994 19364 01 19363 01' 19363 01 4 19362 01 4 19362 01 4 19361 01 94 19360 01 94 19359 01 94 19359 01 94 19359 01 94 19357 02 994 19356 02 994 19356 02 994 19355 02 994 19353 02 994 19353 02' 994 19353 02~ 19352 02 19352 02' 4 19352 02 4 19350 02 4 19350 02 94 19350 02 94 19349 02 94 19349 02 94 19348 02 994 19348 02 994 19348 02 994 19348 02 /1994 19349 02 994 19350 03' 994 19352 03 19353 03 19354 03 4 19355 03 4 19359 03 4 19360 03 4 19360 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement page 2 FUEL LOGGING RE~T -- NONMETERED TANKS TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS REMARKS 03 4 19363 03 4 19363 03 4 19367 03 94 19368 03 94 19369 03 94 19370 03 94 19371 03 994 19374 03 994 19376 03 994 19377 03 994 19377 03 994 19378 03' 19379 03 19380 03' 4 19380 03 4 19381 04 4 19382 04 94 19386 04 94 19387 04 94 19388 04 94 19390 04 994 19390 04 994 19199 04 /1994 19200 04 994 19201 04 994 19202 04 19203 04~ 19208 04 4 19210 04 4 19210 04 4 19211 04 94 19212 04 94 19216 04 94 19215 04 94 19215 04 94 19215 04 994 19216 05 994 19217 05 994 19218 05 994 19219 05 994 19220 05 19220 05 19223 05 4 19224 05 4 19225 05~ 4 19226 05 94 19226 05 94 19229 Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement page 3 FUEL LOGGING REPORT -- NONMETERED TANKS TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA~ AGENCY ID : CATO80020415 DATE GALLONS REMARKS 05 94 19231 05 94 19231 05 994 19232 05 994 19233 05 994 19236 05 994 19236 05 994 18714 05 994 18543 05 /1994 18546 05 994 18550 05 994 18552 06 994 18553 06' 18555 06 f1994 18557 06 /1994 18392 06 I1994 18394 06 4 18396 06~ 4 18396 06 4 18400 06 4 18403 06 4 18405 06 4 18406 06 4 18410 06 4 18410 06 94 18413 06 94 18416 06 94 18416 06 94 18417 06 94 18419 06 94 18428 06 94 18430 06 94 18431 06 94 18435 07 94 18437 07 94 18443 07 994 18445 07 994 18447 07 994 18449 07 994 18454 07 994 18465 07 994 18460 07 994 18465 07 994 18471 07' 18488 07 /1994 18500 07 ~1994 18493 07 ~1994 18512 07~ I1994 18507 Generator Run Generator Run Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement page 4 FUEL LOGGING RE T -- NONMETERED TANKS page 5 TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS REMARKS 07 94 18498 07 94 18526 07 94 18518 07 94 18532 07 94 18706 07 994 10000 08 994 18702 08 994 18721 08 994 18712 08 994 18749 08 994 18698 08 994 18677 08 994 18685 08 994 18698 08 /1994 16362 08 994 16366 08 /1994 16372 08 /1994 18705 08 994 18710 08 994 18715 08 994 18712 08 994 18696 08 994 18714 08 994 18713 08 994 18734 08 994 18704 08 994 18742 08 994 18757 08 18708 09 I1994 18733 09 11994 18775 09 I1994 18775 09 /1994 18705 09 I1994 18721 09' 11994 18716 09 ~1994 18742 09' 18767 09 ~1994 18734 09 ~1994 18731 09 4 18746 09' 4 18729 09 4 18748 09 4 18769 09 4 18783 09 4 18791 09~ 4 18769 09 4 18707 09 4 18724 Installed new probe 12" shorter p/Roger PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING RE T -- NONMETERED TANKS page 6 TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS REMARKS 09 994 18733 09 /1994 18724 09 /1994 18732 10 994 18739 10 /1994 18708 10 /1994 18706 10 /1994 18716 10 994 18728 10 994 18728 10 994 18681 10 994 18734 10 994 18656 10 994 18655 10 994 18650 10 994 18648 10 994 18645 10' 994 18645 10' 18643 10 994 18637 10~ 18636 10 I1994 18634 10~ ~1994 18633 10 /1994 18641 10 ~1994 18638 11 ~1994 18636 11' I1994 18634 11 4 18632 11 4 18631 11 4 18624 11 4 18623 11 4 18621 11 4 18616 11 4 18614 11 4 18607 11 4 18605 11 4 18603 11 4 18601 11 94 18598 11 94 18591 11 94 18589 11 94 18586 11 94 18584 11 94 18582 11 94 18575 11 94 18574 11 94 18572 12 94 18570 12 94 18569 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING RE TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 -- NONMETERED TANKS DATE GALLONS REMARKS 12 94 18563 12 94 18562 12 94 18560 12 994 18559 12 994 18557 12 /1994 18553 12 994 18551 12 18550 12' 18549 12 4 18547 12 4 18544 12 4 18542 12 94 18541 12 94 18540 12 94 18538 12 94 18531 12 94 18529 12 994 18528 12 994 18527 12 994 18524 page 7 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement C~RRECTION N OTiJiI~_ E BAKERSFIELD FIRE DEPARTMENT Coro No Locatior ~/k;, ,~ (C ~? [f Sub Viv./P/~ ]>1 ~ $1k. . ~t, You are hereby required to make the following corrections at the above location: Completion Date for Corrections Date ,~'J~"/,~,~- Inspector 326-3979 UNDERGROUND STORAGE I KINSPECT,!ON . -. Bakersfield Fire Dept. Hazardous Materials Division Bakersfield, CA 93301 FAClLITYNAME ~Ce:~,'~'. ~3~, .~.,~i~x /~.(~ BUSINESS I.D. No. 215-000 ~ FACILITY ADDRESS Ici't~ gl,1 ~ CITY ~¢~'~'-[ ZIPCODE C?~e~t~[ FACILITY PHONE No. I~ , u~t Product Product TIME IN TIME OUT \~e.~O-,~_ In~ Date Inst Date Inst Date Size Size Size ROUTINE ~_/ FOLLOW-UP REQUIREMENTS yes no n/a yes no n/a yes no n/a la. Forms A & B Submitted lb. Fora1 C Submitted lc. Operating Fees Paid ld. State Surcharge Paid le. Statement of Financial Responsibility Submitted lf. Written Contract Exists between Owner & Operator to Operate UST 2a. Valid Operating Permit 2b. Approved Written Routine Monitoring Procedure ~ v/ 2c. Unauthorized Release Response Plan 3a. Tank Integrity Test in Last 12 Months J C')/~)~1 /~-J 3b. Pressurized Piping Integrity Test in Last 12 Months 3c. Suction Piping Tightness Test in Last 3 Years I/~,[~' c,,, ~ 3d. Gravity Flow Piping Tightness Test in Last 2 Years 3e. Test Results Submitted Within 30 Days 3f. Daily Visual Monitoring of Suction Product Piping 4a. Manual Inventory Reconciliation Each Month 4b. Annual Inventory Reconciliation Statement Submitted 4c. Meters Calibrated Annually 5. Weekly Manual Tank Gauging Records for Small Tanks 6. Monthly Statistical Inventory Reconciliation Results I...~ 7. Monthly Automatic Tank Gauging Results 8. Ground Water Monitoring 9. Vapor Monitoring 10. Continuous Interstitial Monitoring for Double-Walled Tanks 11. Mechanical Line Leak Detectors 12. Electronic Line Leak Detectors 13. Continuous Piping Monitoring in Sumps , ~,~ 14. Automatic Pump Shut-off Capability 15. Annual Maintenance/Calibration of Leak Detection Equipment 16. Leak Detection Equipment and Test Methods Listed in LG-113 Series 17. Written Records Maintained on Site 18. Reported Changes in Usage/Conditions to Operating/Monitoring Procedures of UST System Within 30 Days 19. Repo~ted Unauthorized Release Within 24 Hours 20. Approved UST System Repairs and Upgrades 21. Records Showing Cathodic Protection Inspection 22. Secured Monitoring Wells 23. Drop Tube L~ RE-INSPECTION DATE _ '~/,~/.~.'-~_ RECEIVED BY: ~ ,~. _~ .~ INSPECTOR: ~~~~./~ OFFICE TELEPHONE No. ~ -~gTq BAKERSFIELD FIRE DEPARTMENT HAZARDOUS MATERIAL DIVISION 1715 CHESTER AVE., BAKERSFIELD, CA (805) 326-3979 93304. APPLICATION TO PERFORM A TIGHTNESS TEST PERMIT TO OPERATE ~ NUMBER OF TANKS TO BE TESTED TANK~ VOLUME OWNERS NAME IS .PIPING GOING TO'BE TESTED CONTENTS TANK TESTING COMP TEST METHOD ~Ld~tl STATE REGISTRATION DATE & TIME TEST IS TO BE CONDUCTED - L A~OVED~_.X~ . DATE SIGNATURE OF APPLICANT Environmental Mana¢ 2600 Camino Ramon, Room 2E050 San Ramon, California 94583 PACIFIC~;~BELL ~ A Pacific Telesis Company May23,1994 City of Bakerfield Mr. Ralph E. Huey Haz. Mat. Coordinator Bakersfield City Fire Dept. 2130 G. Street Bakersfield, CA 93301 Mr. Ralph'E. Huey: Enclosed is the State of California State Water Resources Control Board Certification of Financial Responsibility form which I have completed with an attached list of Pacific Bell sites that have fuel tanks on the premises within your county. If you have any questions please give call me on 510-867-5025. Klm Melville Environmental Management CERTIFICATION FOR UNDERGROUND STOOGE TANKS CO~AINING P~O~M Chief Pacific ~ell Not applicable Renewed Yes Yes Financial 2600 Camine ~on for State ~,8~0,~. Annually Officer San ~n, ~ 94583 Alternative Letter Roem 2E050 Mechanism PacJfJc Be]~ Please see attached. ~ ~ ;~~ ~ -~ ~ -9 q Staff Associate REPORT DATE: 02/24/94 LUST/IS PA6E: 10 ~.ANK LISTING REPORT TANK aDDRESS CLLC GEOPAR COUNTY PRODUCT 508 1029 S. 2ND ST EL C~RO, 509 1029 S. 2ND ST EL CI~ITRO, CA 592 1029 S. 2ND ST EL CENTRO, CA 593 1029 S. 2ND ST I1 EL CENTRO, CA 941 1029 S. 2ND ST EL CENTRO, CA 1540 763 STATE ST. EL CENTRO, CA 325 466 PINE STREET HOLTVILLE, CA 328 108 E 9TH STREET IMPERIAL, CA 325 315 E N~IN STREET NILAND, CA 327 HOT MINERAL SPA ROAD NILAND, CA ELCNCASO DA618 IMPERIAL ELCNCASO DA618 IMPERIAL ELCNCASO DA618 IMPERIAL ELCNCASO DA618 IMPERIAL ELCNCASO DA-618 IMPERIAL ELCNCA01 DA-122 IMPERIAL HLVLCAll DA-124 IMPERIAL IMPRCAll DA-126 IMPERIAL NILDCA11 DA-132 IMPERIAL NILDCA12 DA-206 IMPERIAL 329 HYlgO/1 MI/N/O TEXAS SPR FRCKCAll LB-229 INYO FURNACE CREEK, CA 330 SHEEPSHEADPASS SHSHCAll LB-228 INYO SHOSHONE, CA 287 101 V ST BKFDCA63 SA607 KERN BAKERSFIELD, CA 288 5650 ALDRIN CT. BKFDCA53 SA?03 KERN BAKERSFIELD, CA 289 5650 ILDRXN CT. BKFDCA53 SA703 KERN BAKERSFIELD, CA 331 1918 M STREET BKFDCA12 SA004 KERN BAKERSFIELD, CA 332 300 MEEDPATCH HWY BKFDCAll SA-006 KERN BAKERSFIELD, CA PROPRIETARY INFORIIATION : Not for use or disclosure outside Pacific Bell except under written agreement UNLEADED DIESEL2 UNLF~DED DIESEL2 WASTE OIL DIESEL1 DIESEL1 DIESEL1 DIESEL1 DIESEL1 DIESEL1 DIESEL1 UNLEADED UNLEADED DIESEL2 DIESEL1 DIESEL1 REPORT DATE: 02/24/94 PAGE: 11 LUST/IS LISTING REPORT T~K ADDRESS GEOPAR COUNTY PRODUCT 333. 3221 SO. It STREET BAKERSFIELD, CA BKFDCA14 SA098 KERN 334 3501 COLUMBUS BKFDCA13 SA-114 KERN BAKERSFIELD, CA 335 11609 ROSEDAhE HWY BKFDCA17 SA-224 KERN  .~ BAKERSFIELD, CA 800 5650 AhDRIN CT. B~DCAIA SA703 ~RN BA~RSFIE~, CA 990 11101 WHITE lANE BKFDCA19 SA-532 KERN BAKERSFIELD, CA 336 2MI/N/O DEI~O E/S HY 99 DELNCAlC SA-025 KERN DEhANO, CA 337 925 JEFFERSON STREET DEhNCAll SA-149 KERN DEI~O, CA 338 FORBES & PAYNE STREETS EDWRCA01 SA029 KERN EDWARDS, CA 339 8313 E. SEGRUE ROAD I~ONT, CA 340 2100 BELSHAW AVENUE MOJAVE, CA LAMTCAll SA010 KERN MOJVCAO1 SA-058 KERN 341 1021 CALIFORNIA ST. OLDLCAll SA-O13 KERN OILDALE, CA 1035 1021 CALIFORNIA ST. OLDLCAll SA-013 KERN OILDALE,'CA LEBCCA12 8A-322 KERN 342 16251 ASKIN DRIVE PINE MOUNTAIN, LEBEC, CA 343 279 N/O WILLOW SPRO. RD. RSMDCAll SA-064 KERN ROSAMUND, CA 204 11091 10 1/2 AVENUE HNFRCA50 SDRO0 KINGS HANFORD, CA 205 11091 10 1/2 AVENUE BNFRCA50 SDR00 KINGS HANFORD, CA 345 516 N. DOUTY STREET HNFRCA01 SD-020 KINGS IIANFORD, CA DIESEL1 DIESEL1 DIESEL1 WASTE OIL DIESEL1 WASTE OIL DIESEL1 DIESEL1 DIESEL1 WASTE OIL DIESEL1 DIESEL2 DIESEL1 DIESEL1 UNI,P. ADED DIESEL2 DIESEL1 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under writ.ten agreement April 11, 1994 RECEIVED t) 1994 HAZ. MAT. DIV. PACIFiC~;~BELL ® A Pacific Telesis Company C. $. Nantze Fleet Supervisor 1420 Tuolumne Room 300 Fresno, CA 93762 Bakersfield City Fire Department 2130 "G" Street Bakersfield, CA 93301 Attention: Ralph Huey: Attached is Pacific Bell's Underground Tanks Reconciliation Disclosure for the period from January 1, 1994 through March 31, 1994. If you have any questions, please call Connie Silva on (209)442-2345. Thank you. C. S. Nantze Fleet Supervisor CSN:Iu Attachments FUEL LOGGING REPORT -- NONMETERED TANKS page 1 KERN COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH HAZARDOUS MATERIALS SECTION - UNDERGROUND TANK PROGRAM INVENTORY REPORT 01/01/1994 TO 03/31/1994 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 2 TANK ID : STREET : CITY/STATE: AGENCY ID : 331 1918 M STREET BAKERSFIELD CA CATO80020415 DATE GALLONS REMARKS 01/03/1994 19381 01/04/1994 19380 01/05/1994 19378 01/06/1994 19377 01/07/1994 19375 01/10/1994 19371 01/11/1994 19370 01/12/1994 19370 01/13/1994 19369 01/14/1994 19367 01/17/1994 19364 01/18/1994 19363 01/19/1994 19363 01/20/1994 19362 01/21/1994 19362 01/24/1994 19361 01/25/1994 19360 01/26/1994 19359 01/27/1994 19359 01/28/1994 19359 01/31/1994 19357 02/01/1994 19356 02/02/1994 19356 02/03/1994 19355 02/04/1994 19353 02/07/1994 19353 02/08/1994 19353 02/09/1994 19352 02/10/1994 19352 02/11/1994 19352 02/14/1994 19350 02/15/1994 19350 02/16/1994 19350 02/17/1994 19349 02/18/1994 19349 02/21/1994 19348 02/22/1994 19348 02/23/1994 19348 02/24/1994 19348 02/25/1994 19349 02/28/1994 19350 03/01/1994 19352 03/02/1994 19353 03/03/1994 19354 03/04/1994 19355 03/07/1994 19359 03/08/1994 19360 03/09/1994 19360 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under use or disclosure written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 3 TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS REMARKS 03/10/1994 19363 03/11/1994 19363 03/14/1994 19367 03/15/1994 19368 03/16/1994 19369 03/17/1994 19370 03/18/1994 19371 03/21/1994 19374 03/22/1994 19376 03/23/1994 19377 03/24/1994 19377 03/25/1994 19378 03/28/1994 19379 03/29/1994 19380 03/30/1994 19380 03/31/1994 19381 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 4 TANK ID : STREET : CITY/STATE: AGENCY ID : 333 3221 SO. H STREET BAKERSFIELD CA CATO80020514 DATE GALLONS REMARKS 01/03/1994 3145 01/04/1994 3145 01/05/1994 3145 01/06/1994 3144 01/07/1994 3144 01/10/1994 3144 01/11/1994 3144 01/12/1994 3143 01/13/1994 3143 01/14/1994 3143 01/17/1994 3142 01/18/1994 3142 01/19/1994 3142 01/20/1994 3141 01/21/1994 3142 01/24/1994 3141 01/25/1994 3141 01/26/1994 3141 01/27/1994 3141 01/28/1994 3141 01/31/1994 3140 02/01/1994 3141 02/02/1994 3141 02/03/1994 3141 02/04/1994 3140 02/07/1994 3141 02/08/1994 3140 02/09/1994 3140 02/10/1994 3133 02/11/1994 3132 02/14/1994 3132 02/15/1994 3132 02/16/1994 3132 02/17/1994 3132 02/18/1994 3132 02/21/1994 3132 02/22/1994 3132 02/23/1994 3131 02/24/1994 3131 02/25/1994 3131 02/28/1994 3131 03/01/1994 3132 03/02/1994 3132 03/03/1994 3132 03/04/1994 3132 03/07/1994 3132 03/08/1994 3132 03/09/1994 3132 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under Generator Run use or disclosure written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 5 TANK ID : 333 STREET : 3221 SO. H STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CAT080020514 DATE GALLONS REMARKS 03/10/1994 3132 03/11/1994 3133 03/14/1994 3134 03/15/1994 3133 03/16/1994 3134 03/17/1994 3134 03/18/1994 3133 03/21/1994 3134 03/22/1994 3134 03/23/1994 3134 03/24/1994 3134 03/25/1994 3124 03/28/1994 3124 03/29/1994 3124 03/30/1994 3124 03/31/1994 3124 Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 6 TANK ID : STREET : CITY/STATE: AGENCY ID : 334 3501 COLUMBUS BAKERSFIELD CA CAT080020548 DATE GALLONS REMARKS 01/03/1994 862 01/04/1994 862 01/05/1994 835 01/06/1994 835 01/07/1994 835 01/10/1994 835 01/11/1994 835 01/12/1994 835 01/13/1994 835 01/14/1994 835 01/17/1994 834 01/18/1994 834 01/19/1994 834 01/20/1994 834 01/21/1994 834 01/24/1994 834 01/25/1994 834 01/26/1994 834 01/27/1994 834 01/28/1994 834 01/31/1994 834 02/01/1994 834 02/02/1994 834 02/03/1994 834 02/04/1994 834 02/07/1994 834 02/08/1994 834 02/09/1994 834 02/10/1994 807 02/11/1994 807 02/14/1994 807 02/15/1994 808 02/16/1994 807 02/17/1994 807 02/18/1994 807 02/21/1994 807 02/22/1994 807 02/23/1994 807 02/24/1994 807 02/25/1994 807 02/28/1994 807 03/01/1994 807 03/02/1994 807 03/03/1994 807 03/04/1994 808 03/07/1994 808 03/08/1994 808 03/09/1994 808 PROPRIETARY outside Paci INFORMATION : Not for fic Bell except under Generator Run Generator Run use or disclosure written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 7 TANK ID : 334 STREET : 3501 COLUMBUS CITY/STATE: BAKERSFIELD CA AGENCY ID : CAT080020548 DATE GALLONS REMARKS 03/10/1994 808 03/11/1994 808 03/14/1994 808 03/15/1994 808 03/16/1994 808 03/17/1994 808 03/18/1994 808 03/21/1994 808 03/22/1994 808 03/23/1994 808 03/24/1994 809 03/25/1994 808 03/28/1994 809 03/29/1994 808 03/30/1994 809 03/31/1994 809 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS TANK ID : STREET : CITY/STATE: AGENCY ID : 335 11609 ROSEDALE BAKERSFIELD CA CATO80020597 HWY DATE GALLONS REMARKS 01/03/1994 833 01/04/1994 833 01/05/1994 833 01/06/1994 833 01/07/1994 833 01/10/1994 809 01/11/1994 809 01/12/1994 808 01/13/1994 808 01/14/1994 808 01/17/1994 807 01/18/1994 808 01/19/1994 808 01/20/1994 807 01/21/1994 807 01/24/1994 807 01/25/1994 807 01/26/1994 807 01/27/1994 808 01/28/1994 807 01/31/1994 807 02/01/1994 807 02/02/1994 807 02/03/1994 807 02/04/1994 807 02/07/1994 807 02/08/1994 807 02/09/1994 807 02/10/1994 803 02/11/1994 803 02/14/1994 803 02/15/1994 803 02/16/1994 803 02/17/1994 803 02/18/1994 803 02/21/1994 803 02/22/1994 803 02/23/1994 803 02/24/1994 803 02/25/1994 803 02/28/1994 803 03/01/1994 803 03/02/1994 804 03/03/1994 804 03/04/1994 804 03/07/1994 804 03/08/1994 804 03/09/1994 804 Generator Run Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement page 8 FUEL LOGGING REPORT -- NONMETERED TANKS page 9 TANK ID : 335 STREET : 11609 ROSEDALE HWY CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020597 DATE GALLONS REMARKS 03/10/1994 804 03/11/1994 804 03/14/1994 804 03/15/1994 804 03/16/1994 805 03/17/1994 805 03/18/1994 805 03/21/1994 805 03/22/1994 805 03/23/1994 805 03/24/1994 805 03/25/1994 805 03/28/1994 805 03/29/1994 805 03/30/1994 805 03/31/1994 805 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 10 TANK ID : 337 STREET : 925 JEFFERSON STREET CITY/STATE: DELANO CA AGENCY ID : CAT080020571 DATE GALLONS REMARKS 01/03/1994 777 01/04/1994 777 01/05/1994 777 01/06/1994 777 01/07/1994 777 01/10/1994 777 01/11/1994 777 01/12/1994 777 01/13/1994 777 01/14/1994 777 01/17/1994 776 01/18/1994 776 01/19/1994 756 01/20/1994 756 01/21/1994 756 01/24/1994 756 01/25/1994 756 01/26/1994 756 01/27/1994 756 01/28/1994 756 01/31/1994 755 02/01/1994 755 02/02/1994 755 02/03/1994 755 02/04/1994 755 02/07/1994 756 02/08/1994 755 02/09/1994 755 02/10/1994 755 02/11/1994 755 02/14/1994 756 02/15/1994 755 02/16/1994 756 02/17/1994 756 02/18/1994 755 02/21/1994 755 02/22/1994 755 02/23/1994 755 02/24/1994 756 02/25/1994 756 02/28/1994 752 03/01/1994 752 03/02/1994 752 03/03/1994 752 03/04/1994 753 03/07/1994 753 03/08/1994 753 03/09/1994 753 Generator Run Generator Run Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 11 TANK ID : 337 STREET : 925 JEFFERSON STREET CITY/STATE: DELANO CA AGENCY ID : CAT080020571 DATE GALLONS REMARKS 03/10/1994 753 03/11/1994 753 03/14/1994 753 03/15/1994 753 03/16/1994 753 03/17/1994 750 03/18/1994 751 03/21/1994 751 03/22/1994 751 03/23/1994 751 03/24/1994 751 03/25/1994 751 03/28/1994 751 03/29/1994 751 03/30/1994 751 03/31/1994 751 Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 12 TANK ID : STREET : CITY/STATE: AGENCY ID : 99O 11101 WHITE LANE BAKERSFIELD CA NONE DATE GALLONS REMARKS 01/03/1994 605 01/04/1994 605 01/05/1994 605 01/06/1994 605 01/07/1994 605 01/10/1994 605 01/11/1994 605 01/12/1994 605 01/13/1994 605 01/14/1994 599 01/17/1994 599 01/18/1994 599 01/19/1994 599 01/20/1994 599 01/21/1994 599 01/24/1994 593 01/25/1994 593 01/26/1994 593 01/27/1994 593 01/28/1994 593 01/31/1994 593 02/01/1994 593 02/02/1994 593 02/03/1994 593 02/04/1994 593 02/07/1994 593 02/08/1994 593 02/09/1994 593 02/10/1994 587 02/11/1994 587 02/14/1994 587 02/15/1994 587 02/16/1994 587 02/17/1994 587 02/18/1994 587 02/21/1994 587 02/22/1994 587 02/23/1994 587 02/24/1994 587 02/25/1994 587 02/28/1994 587 03/01/1994 587 03/02/1994 575 03/03/1994 575 03/04/1994 575 03/07/1994 575 03/08/1994 575 03/09/1994 576 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under Generator Run Generator Run Generator Run Generator Run use or disclosure written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 13 TANK ID : 990 STREET : 11101 WHITE LANE CITY/STATE: BAKERSFIELD CA AGENCY ID : NONE DATE GALLONS 03/10/1994 575 03/11/1994 576 03/14/1994 576 03/15/1994 576 03/16/1994 576 03/17/1994 576 03/18/1994 576 03/21/1994 576 03/22/1994 576 03/23/1994 576 03/24/1994 576 03/25/1994 576 03/28/1994 576 03/29/1994 576 03/30/1994 576 03/31/1994 576 REMARKS PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 14 TANK ID : STREET : CITY/STATE: AGENCY ID : 1035 1021 CALIFORNIA ST. OILDALE CA CAT080020449 DATE GALLONS REMARKS 01/03/1994 1852 01/04/1994 1852 01/05/1994 1852 01/06/1994 1851 01/07/1994 1851 01/10/1994 1851 01/11/1994 1851 01/12/1994 1851 01/13/1994 1851 01/14/1994 1841 01/17/1994 1841 01/18/1994 1841 01/19/1994 1841 01/20/1994 1841 01/21/1994 1841 01/24/1994 1841 01/25/1994 1841 01/26/1994 1841 01/27/1994 1841 01/28/1994 1840 01/31/1994 1840 02/01/1994 1840 02/02/1994 1840 02/03/1994 1840 02/04/1994 1840 02/07/1994 1840 02/08/1994 1840 02/09/1994 1840 02/10/1994 1837 02/11/1994 1837 02/14/1994 1837 02/15/1994 1837 02/16/1994 1837 02/17/1994 1837 02/18/1994 1837 02/21/1994' 1837 02/22/1994 1837 02/23/1994 1837 02/24/1994 1837 02/25/1994 1837 02/28/1994 1837 03/01/1994 1837 03/02/1994 1837 03/03/1994 1837 03/04/1994 1838 03/07/1994 1838 03/08/1994 1838 03/09/1994 1838 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under Generator Run Generator Run use or disclosure written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 15 TANK ID : 1035 STREET : 1021 CALIFORNIA ST. CITY/STATE: OILDALE CA AGENCY ID : CATO80020449 DATE GALLONS REMARKS 03/10/1994 1839 03/11/1994 1839 03/14/1994 1839 03/15/1994 1839 03/16/1994 1839 03/17/1994 1832 03/18/1994 1832 03/21/1994 1833 03/22/1994 1833 03/23/1994 1833 03/24/1994 1833 03/25/1994 1833 03/28/1994 1833 03/29/1994 1833 03/30/1994 1833 03/31/1994 1833 Generator Run PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 16 TANK ID : 1057 STREET : 8313 E. SEGRUE ROAD CITY/STATE: LAMONT CA AGENCY ID : CATO80020431 DATE GALLONS REMARKS 03/31/1994 1011 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS TANK ID : 1058 STREET : FORBES & PAYNE STREETS CITY/STATE: EDWARDS CA AGENCY ID : CAD981983422 DATE GALLONS REMARKS 03/31/1994 965 page 17 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement KERN COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH HAZARDOUS MATERIALS SECTION - - UNDERGROUND TANK PROGRAM INVENTORY RECONCILIATION REPORT 01/01/94 TO 03/31/94 TANK 288 TANK 289 AGENCY TANK ID: ADDRESS: AGENCY TANK ID: ADDRESS: CAD981 63O411 5650 ALDRIN CT. BAKERSFIELD, CA CAD981 630411 5650 ALDRIN CT. BAKERSFIELD, CA FOR THE REPORTING PERIOD OF 01/01/94 TO 03/31/94, I HEREBY CERTIFY THAT DAILY INVENTORY RECONCILIATION RECORDS HAVE SHOWN VALUES WITHIN ALLOWABLE ERROR LIMITS SET BY THE WATER RESOURCES CONTROL BOARD FOR THE ABOVE TANKS. I REALIZE THAT MISREPRESENTATIONS OF DATA ON THIS FORM MAY RESULT IN CIVIL PENALTIES OF UP TO $25,000 PER DAY PER VIOLATION PERSUANT TO SECTION 25819 OF THE CALIFORNIA HEALTH AND SAFETY CODE. NAME: C. S. Nantze SIGNATURE: TITLE: Fleet Supervisor DATE: 4/11/94 Pacific Bell Fuel Unit 1420 Tuolumne St., Room 300 Fresno, California 93762 PROPRIETARY INFORMATION: Not for use or disclosure outside Pacific Bell except under written agreement PACIFIC I~IBELL A Pacific Telesis Company P. J. Doyle Fleet/Material Supervisor 1420 Tuolumne Room 300 Fresno, CA 93762 October 12, 1993 Bakersfield City Fire Department 2130 "G" Street Bakersfield, CA 93301 Attention: Joe Dunwoody RECEIVED HAZ. MAT. DIV. Attached is Pacific Bell's Underground Tanks Reconciliation Disclosure for the period from July 1, 1993 through September 30, 1993. If you have any questions, please call Connie Silva on (209)442-2345. Thank you. P. J. Doyle Fleet/Material Supervisor PJD:Iu Attachments FUEL LOGGING REPORT -- NONMETERED TANKS KERN COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH HAZARDOUS MATERIALS SECTION - UNDERGROUND TANK PROGRAM INVENTORY REPORT 07/01/1993 TO 09/30/1993 page 1 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REP~ -- NONMETERED TANKS page TANK ID : STREET : CITY/STATE: AGENCY ID : 331 1918 M STREET BAKERSFIELD CA CATO80020415 DATE GALLONS REMARKS 07/01/1993 19629 07/02/1993 19631 07/05/1993 19635 07/06/1993 19637 07/07/1993 19639 07/08/1993 19640 07/09/1993 19642 07/12/1993 19646 07/13/1993 19649 07/14/1993 19650 07/15/1993 19651 07/16/1993 19653 07/19/1993 19656 07/20/1993 19500 07/21/1993 19501 07/22/1993 19502 07/23/1993 19502 07/26/1993 19505 07/27/1993 19506 07/28/1993 19507 07/29/1993 19508 07/30/1993 19508 08/02/1993 19511 08/03/1993 19512 08/04/1993 19513 08/05/1993 19514 08/06/1993 19515 08/09/1993 19519 08/10/1993 19519 08/11/1993 19521 08/12/1993 19521 08/13/1993 19521 08/16/1993 19523 08/17/1993 19524 08/18/1993 19525 08/19/1993 19524 08/20/1993 19525 08/23/1993 19526 08/24/1993 19526 08/25/1993 19526 08/26/1993 19526 08/27/1993 19527 08/30/1993 19529 08/31/1993 19530 09/01/1993 19530 09/02/1993 19531 09/03/1993 19531 09/06/1993 19532 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under Generator Run use or disclosure written agreement FUEL LOGGING REPOT -- NONMETERED TANKS page 3 TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS REMARKS 09/07/1993 19533 09/08/1993 19533 09/09/1993 19534 09/10/1993 19534 09/13/1993 19535 09/14/1993 19535 09/15/1993 19535 09/16/1993 19535 ~ 09/17/1993 19534 09/20/1993 19531 09/21/1993 19531 09/22/1993 19530 09/23/1993 19529 09/24/1993 19524 09/27/1993 19525 09/28/1993 19524 09/29/1993 19524 09/30/1993 19523 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement PACIFIC~I~BELL A Pacific Telesis Company C. S. Nantze Fleet Supervisor 1420 Tuolumne Room 300 Fresno, CA 93762 July 12, 1993 Bakersfield City Fire Department 2130 "G" Street Bakersfield, CA 93301 RECEIVED JUL I 4.1 YJ HAZ. MAT. DIV. Attention: Joe Dunwoody Attached is Pacific Bell's Underground Tanks Reconciliation Disclosure for the period from April 1, 1993 through June 30, 1993. If you have any questions, please call Connie Silva on (209)442-2345. Thank you. C. S. Nantze Fleet Supervisor CSN:sp Attachments FUEL LOGGING REPORT -- NONMETERED TANKS KERN COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH HAZARDOUS MATERIALS SECTION - UNDERGROUND TANK PROGRAM INVENTORY REPORT 04/01/1993 TO 06/30/1993 page 1 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement FUEL LOGGING REPORT -- NONMETERED TANKS page 2 TANK ID : STREET : CITY/STATE: AGENCY ID : 331 1918 M STREET BAKERSFIELD CA CATO80020415 DATE GALLONS REMARKS 04/01/1993 19521 04/02/1993 19523 04/05/1993 19523 04/06/1993 19524 04/07/1993 19524 04/08/1993 19525 04/09/1993 19526 04/12/1993 19529 04/13/1993 19530 04/14/1993 19530 04/15/1993 19532 04/16/1993 19533 04/19/1993 19536 04/20/1993 19537 04/21/1993 19538 04/22/1993 19539 04/23/1993 19540 04/26/1993 19544 04/27/1993 19544 04/28/1993 19545 04/29/1993 19546 04/30/1993 19547 05/03/1993 19551 05/04/1993 19553 05/05/1993 19555 05/06/1993 19557 05/07/1993 19558 05/10/1993 19562 05/11/1993 19563 05/12/1993 19565 05/13/1993 19567 05/14/1993 19568 05/17/1993 19572 05/18/1993 19574 05/19/1993 19575 05/20/1993 19576 05/21/1993 19578 05/24/1993 19581 05/25/1993 19582 05/26/1993 19584 05/27/1993 19586 05/28/1993 19587 05/31/1993 19591 06/01/1993 19592 06/02/1993 19594 06/03/1993 19594 06/04/1993 19595 06/07/1993 19597 PROPRIETARY INFORMATION : Not for outside Pacific Bell except under use or disclosure written agreement FUEL LOGGING REPORT -- NONMETERED TANKS TANK ID : 331 STREET : 1918 M STREET CITY/STATE: BAKERSFIELD CA AGENCY ID : CATO80020415 DATE GALLONS REMARKS 06/08/1993 19598 06/09/1993 19598 06/10/1993 19598 06/11/1993~ 19599 06/14/1993 19602 06/15/1993 19603 06/16/1993 19603 06/17/1993 19605 06/18/1993 19607 06/21/1993 19611 06/22/1993 19613 06/23/1993 19615 06/24/1993 19617 06/25/1993 19618 06/28/1993 19623 06/29/1993 19625 06/30/1993 19627 page 3 PROPRIETARY INFORMATION : Not for use or disclosure outside Pacific Bell except under written agreement .-~) ,~AZARDOUS MATERI..ALS DIVISION ~ ~ ~ ..................... . 130 G Street,(805)Baker~fleld,326 3970 CA~301 ~/ REC ~///~ UNDERGROUND TANK ~i~STIONNAIRE JUL 2 ~, 1991 I. FACILITY/SITE No. OF~ANK$ \ ~~ A,s'd ............ k;NAME OF OPE~TOR DBA OR FACILI1Y NAME ADDRESS CITY NAME BOX TO INDICATE [~ CORPORATION 1YPE O~ BUSINESS [~ 1 GAS STATION NEARF~T CRO~ STREET PARCEL NO.(OPTIO.N~t L) STAI~ ZIP CODE INDIVIDUAL {~ PARTNERSHIP {~ LOCAL AGENCY D~'RICT$ ~ COUN1Y AGENCY (~] STATE AGENCY ~ FEDERAL AGENCY FARM EMERGENCY CONTACT PERSON (PRIMARY} DAYS: NAME (LAST. FIRSI~ PHONE No. WITH AR~A CODE NIGHS: ~ME (~ST, FI~ ~ONE ~. W~ AR~ CODE EMERGENCY CONTACT PERSON (SECONDARY) optional DAYS: NAME (LAST, FIRST) PHONE No. WITH AREA CODE NIGHTS: NAME (LAST, FIRST] PHONE No. WITH AREA CODE II. PROPERTY OWNER INFORMATION (MUST BE COMPLETED) CARE OF ADDRrr~ INFORMATION NAME MA,LINGO. S~EETADDRESS ~. 'D..~= o C~ NAME ~' BOX ~ INDIVIDUAL [~ LOCAL AGENCY [~ STATE AGENCY TO INDICATE [~ PARTNERSHIP [~ COUNTY AGENCY O FEDERAL AGENCY ZiP CODE PHONE No. WITH AREA CODE III. TANKOWNER INFORMATION (MUST BE COMPLETED) NAME MAILING OR STREET ADDRESS Cl~ NAME ~¢~o CARE OF ADDRESS INFORMATION ~' BOX [~ INDIVIDUAL [~ LOCAL AGENCY [~ STATE AGENCY TO INDICATE [~ PARTNERSHIP [~ COUNTY AGENCY [~ FEDERAL AGENCY ZIP CODE PHONE No. WITH AREA CODE OWNER'S DATE VOLUME PRODUCT TANK No. INSTALLED STORED DO YOU HAVE FINANCIAL RESPONSIBILITY? YIN TYPE IN SERVICE ¥/N YIN , ""~ill one segment t for each tank, unless al~anks and piping are constructed of same materials, style and~ype, then only fill one segment out. please identify tanks by owner ID #. I. TANK DESCRIPTION COMPLETE ALL ITEMS -- SPECIFY IF UNKNO~ c. °ATE INST LLED ,O,OAY EAR, \ q 0. TA,K '" ALLONS: oooo III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A. B. AND C, AND ALL THAT APPLIES IN BOX D A. TYPE OF [] 1 DOUBLE WALL SYSTEM [~]~' SINGLE WALL [] 3 SINGLE WALL WITH EXTERIOR LINER [] 95 UNKNOWN [] 4 SECONDARY CONTAINMENT (VAULTED TANI0 [] 99 OTHER B. TANK ~/1 BARE STEEL MATERIAL [] 5 CONCRETE (PdmaryT~nk) [] g BRONZE [] 2 STAINLESS STEEL ~3 FIBERGLASS [] 6 POLYVINYL CHLORIDE [] 7 ALUMINUM [] 113 GALVANIZED STEEL [] 95 UNKNOWN ] 4 STEEL CLAD WI FIBERGLASS REINFORCED PLASTIC ] 8 100% METHANOL COMPATIBLE W/FRP ] 99 OTHER ~--] I RUBBER LINED ~ 2 ALKYD LINING ~ 3 EPOXY LINING ~ 4 PHENOLIC LINING C. INTERIOR [] 5 GLASS LINING [] 6 UNLINED [] 95 UNKNOWN ~--]"99 OTHER LINING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL ? YES_ NO__ D. CORROSION [] 1 POLYETHYLENE WRAP [] 2 COATING PROTECTION [] 5 CATHODIC PROTECTION [] 91 NONE ' [] 3 VINYL WRAP [] 4 FIBERGLASS REINFORCED PLASTIC [] ~ u.~ow. ~ oTHER IV. PIPING INFORMATION ~RCLE A IF ABOVE GROUND Q]~ IF UNDERGROUND, BO1%tlFAPPLICABLE A. SYSTEM TYPE ~'~ 1 A U 3 GRAVITY A U 99 OTHER B. CONSTRUCTION A~'~ I~NGLE~,. WAL~_ A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER C. MATERIAL AND A U 1 8'~RE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE (PVC)A U 4 FIBERGLASS PIPE CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL Wl COATING A U 8 100% METHANOL COMPATtBLEW/FRP PROTECTION A U g GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN .~ U 99 OTHER D. LEAK DETECTION ~, I AUTOMATIC LINE LEAK DETECTOR [] 2 LINE TIGHTNESS TESTING [] 3 IN~F._RSTiT~AL MONUORING [] 99 OTHER V. TANK LEAK DETECTION J[] 1 VISUAL CHECK [] 2 INVENTORY RECONCiLiATiON []3 VAPOR MONITORING ~]4 AUTOMATIC TANK GAUGING [~] 5 GROUNDWATER MONITORING [] ~ T~.NK TEST,.~ [] , ,NTERST,T.ALMON,TOR,NG [] ,~ NONE ~m_] '~ UNKNOWN [] ,~ oTHER EN-V~RONM/IITAL HEALTH SERVICES OEPARiN,T 2?00 "M" STIKILI~ST, SUITE 300, 8AKERSFIEL~CA.93301 (805)861-sss6 UND~RGROUNO HAZARDOUS SUBSTANCE STORAGE FACILITY * INSPECTION REPORT PERMIT(____160027C>] TIME IN ~'~0 'TIME OUT NUMBER PERMIT , Oo:c~,' NO ,~"' iNSPECT;ON TYPE OF INSPECTION: ROUTINE ...........~ ........... REINSDECTION AGF_'_N( OF TAN,K~S:..,.~_.~__]......_...' ATE: COMPLAINT FACILITY NAME:PACiFIC SELL BKSFLO-MAIN OFFTCE FACILITY ADORESS:1918 M STREET 8AKERSF;ELD. CA OWNERS NAME:PACIFIC 8ELL FLEET MANAGEMENT · O P E R A T O R S N A'~'~'Y~'~'YF~""~'~'E'~ ...................................................................................... : COMMENTS: STEM ViOLATrONS/O~ERVATION$ PRIMARY CONTAINMENT MONITORING: a. Intercepting an directing system b. Standard Inventory Control c. Moa!flea ]nventor~ Control ~in-tank Level Sensing Device e. Groundwater MonitoriPg f. Vadosm Zone Monitoring SECONDARY CONTAINMENT MONITORING: Liner Oou~le-Waileo :ank Vault PI.DING ~ 9ressuri]ed ;u6,.lOn c. ~rav';t7 "\ r , OVERFILL PROTECTION: TIGHTNESS TES!NG ~__~ ?IEN CONSTRUCTiON/MODIFICATIONS :]LOSURE/ASANOONMENT ,~. UNAUTHORIZED 9, MAINTENANCE. GENERAL SAFETY, AND OPERATING CONOITION OF FAC",L[TY dC-,,t~_ ~flO0 -' %%, 33MMEN TS/RECOMMENOAT Z ONS HAZARDOUS MATERIAL DIVISION 2130 G Street, Bakersfield, CA 9330 BAKERSFIELD FIRE DEPARTMENT (805) 326-3979 APPLICATION TO PERFORM A TIGHTNESS 7. 0 199 FACILITY PACFIC BELL PERMIT TO OPERATE 9 57359 OPEP~.TORS NAME JERRY GREEN NUMBER OF TANKS TO BE TESTED ADDRESS 1918 M STREET OWNERS NAME PACiFiC BELL IS PIPINGGOING TO'BE TESTED_.y..F.~ TANK# VOLUME CONTENTS 331 20,000 qal. DIESEL TANK TESTING COMPANY TEST METHOD NDE - VPLT NAME OF'TESTER SEE LIST STATE REGISTRATION % N/A DATE & TIME TEST IS TO BE CONDUCTED ~' D~TE /' -A~ROVED B0 SNAVELY ENTERPRISES ADDRESS PO BOX 5~ CARUTHE~ CERTIFICATION # SEE LIST 1/23/1992 at 8:00 a.m_ 'SIGNATURE OF APPLICANT , ::! .'.:,. [':: ';.,, , Iq'*- " NDE VPLT COMPUTERIZED PRECISION TEST REPORT - PATENT PENDING GENERAL REPORT FORM - @COPYRIGHT 1985 PAGE1 1.Owner c,'f storage tanks C,:,mpar'~y representative PACIFIC BELl.. RENATO MARZAN 2.Mailing address c,f owner 3·Owner phone number 4. Station number 5. Lc, cati~c,n name for tanks Location address for tanks Location ph,:,ne inumber Manager c,r operatc, r 2 N. SECOND ST., SUITE 675 SAN JOSE, CA (408) 491-4335 ~331 PACIFIC BELL 1918 M STREET BAKERSFIELD, CA 9330~ (8A5') '~"-~ JERRY GREEN 6. Regulatory agency KERN 7. Tank designatic, n or ID:~ 8. Date tank was 'tested 9. Testing company Mailing address Testing company phone 10.Technician certifying tank State Certificatic, n Number DIESEl.. 02/07/1'~'~2 SNAVELY ENTERPRISES INC. 13381S. HENDERSON CARUTHERS, CA. 93609 800-345-1633 #90-1114 Capacity c,f ~ank 12.Tank cc, nstructic, n material 20,000 gal Ions STEEL 13. Testing liquid DIESEL 14.UNDERGROUND STORAGE TANK SYSTEM IS CERTIFIED TIGHT AT PRODUCT HEIGHT EQUAL TO OR HIGHER THAN GRADE LEVEL YES Measured Numerical Leakage Rate is:+.010 Gallons Per Hour Loss (+) or Gain (-). This measurement is within the allowable limits established in N~PA 329 for a tight tank system. SNAVELY ENTERPRISES, INCORPORATED -13381 SOUTH HENDERSON P.O. BOX 5 - CARUTHERS, CALIFORNIA 93609 - 800-345-1633 NDE VPLT OOMPUTERIZED PRECISION TEST REPORT~-PATENT PENDING GENERAL REPORT FORM - @COPYRIGHT 1985 PAGE~'7' 2 0, 0 0 0 g a 1 1 ,:, n s DIESEL. DIESEL. STEEL 2 2 118 inche.s 155 ].n chef~ ,4 inches 34 inches 152 inches 3 inches 1 number CAMLOCK SUB/TURBINE .0004508 .850 216000 N/A N/A inches 02/06/1992 17:00 155 inches 1. Capacity of 'the tank 2. Past contents 3. Testing liquid 4. Tank construction material 5. a. Tank inclination (degrees) b. Fill pipe inclination (degrees) 6. a. Internal diameter c,f tank b. Tank bottom to grade level 7. a. Fill pipe internal diameter b. Fiii pipe length c. Top c,f fill pipe to tank bc, ttc, m d. Top of fill pipe to grade level 8. Air vents 9. Type c,f 'fill pipe cap 10.Type c,f pumping system Il.Cc, efficient of thermal expansion 12. Specific gravity ].3.Bulk modulus 14. Vapor reo:,very system 15.Depth of groundwater below grade 16.Date tank was topped for testing 17.Time tank was topped ~for testing-~ 18.Total product level from tank bottom SNAVELY ENTERPRISES, INCORPORATED - 13381S. HENDERSON P.O. BOX 5 - CARUTHERS, CALIFORNIA '~,'~'~,.~ - 800-345-1633 NDE VPLT COMPUTERIZED PRECISION TEST REPORT -PATENT PENDING GENERAL REPORT FORM - @COPYRIGHT .1985 PAGE 3 1. General notes and lc, g entries: ARRIVED AT 07:00. TOOK MEASUREMENTS~ BROUGHT LEVEL ABOVE GRADE, BLED TURBINES FREE OF VAPOR. REMOVED T.i .... D. MONITOR. I PLACED STAND PIPE AND PROCEEDED TO SET UP ]'EST, ........ C~LIBRATED AND BEGAN TEST. PRODUCT LINE TEST WAS NOT PERFORMED DUE TO NO L. EAK DETECTOR. Any ~.special pr,:,cedu-~=,'-~ _.~ c, tl',er than. the NDE Computerized VPLT Tank Testing Prc, cedures. NO 3. Descriptic, n of any repairs made tc, stc, rage tank sy.s:tem p r i c, r t :."., ,'", r d ,..I r i n g 'b h e t e s t · NONE 4. Describe any recommended repairs. INSTALL LEAK DETECTOR 5. Describe any significant delays nc, t caused by tester that resulted in delays in cc, mpleting the test. NONE 6. Describe quantity of liquids removed frc, m tank ,z,r liquids added to, tank by tester from tester storage tanks. 15 GALLONS ADDED TO BLEED AND RAISE ABOVE GRADE 15 GALLONS REMOVED AT END OF TEST 7. D.e.?-, ,~." tank shc, w evidence ,'-f. vapor pc, ckets? N 0 SNAVELY ENTERPRISES, INCORPORATED -13381 S, HENDERSON P.O. BOX 5 - CARUTHERS, CALIFORNIA 93609 -800-345-1633 NDE VPLT COMPUTERIZED PRECISION TEST REPORT!~-PATENT PENDINO GENERAL REPORT FORM - ~COPYRIGHT 19S5 PAGE 4 1. TOTAL TEST CONDUCTION TIME ..- ¢)4: 03:07 h,z, urs Leak rate calculation time : a. start : 08:22:14 hc, urs b..end : 12: 25:21 hc, urs Fluid level above grade Height o'f water present in tank 0 i n c h es 0 i n c h e s PIPING PRESSURE TEST - HYDROSTATIC PRESSURE DATA 4~ Piping pressure test cc, nducted 5. Amc, unt c,f pressure applied to system 6. Am,:::,unt ,"',f pressu'r'e dr,:::,p 7. Elapse(::l time during test 8. System pass c,.r fail NO SEE NOTES psi p s i m .J. n u t es 9. Was turbine pump activated YES 10. If '-!:ull system leakage rates are :i.n excess of allowable limits~ were the owners nc, tified of any additic, nal testing procedures necessary 'bo isolate leakage to the tank c,r tank piping. N/~ il. Have these additional testing prc, cedures been comp].eted? N/A 12.Was helium leal.:: pinp,'",inting services recommended in pinpointing ].ocatic, n c,f leak. NO SNAVELY ENTERPRISES, INCORPORATED - 13381S. HENDERSON P.O. BOX 5 - CARUTHERS, CALIFORNIA 93609 - 800-345-1633 COMPUTERIZED eRIN , AK RATE DATE ' Tank Owner .................... - PAC BELL~i~18 ~STREET Tank Number ................... ~ 20K DIESEL ~3'1 Date of Measurement - 02t0'?11~92 Tank l'empePature .............. ~ Tank Pressure ................. = Basi~ Tank ~olume *~*****~***~ = T~mperature Correction *~*~.~+~ = S'[ra~lfied Corrected V~lume .... *~'- To~at Fluid L, ev~) ............. .. Fluid Pre~=ur'e on T~nk Bet'[om = Total Temperatu~ Change ...... = t ~4,7720 deQree~ F. ,0~8'1 psi, Z0027,~2~ Gallons. 45.079 Gallons, .00~ G~llons. 20878. 705 200'78.74~ Ge [ lon~. 154.77,18B ~nche~. 4.7=J~ -.00052 degree~ F. Tp.t~.~.Level ~.h_~.nge ... .......... = -.Z2514 inches. ; Leak Rats Calculation' Time ..... ~ 01~00:~0 6eOMe~ry Band ................. Ra~e o¢ Temperature Change Volume Change ................. Expected Level Change ......... Measured Level Change Primary &pparen~ Leak Primary Apparent Leek Rate Stra~ Expected Level Change $%rat Apparent Leak S~ra~ Apparent Loak Rate Avg Measured Level Change Avg Volume Chang~ ............. Avg Expected Level Change ..... .... hvg Appa~.en% Leak .............. ArQ Apparent Leak Ra~e ........ ArQ S'[rmt Uolume Change Rvg Stra{ Expec~od Lmv~I Cheng~ Rvg Strmt Apparent Le~k, ""*"*"" Avg S'~r'~t, ¢~pp~ren'l, Leak Rate - 0008 Gallons/Hour, - 08428 degrees F/Hour. - ~g Gallons. - 05192 inch~s. - 02370 inches. - 02~1 -,021 G~lions,/Hour. -.8400 Gallons, -.8S~S? inches. -.OZZ3 Gellon~. -.022 SaViors/Hour. -.03060 lnch~s. -.0125 6allons. -.01677 ~nches. .010 GaJ. lons/HOL~r. -.017Z7 lnch~. .~099 GaI;Lon~. ,0)0 ~llona/Hour'. ,,, // /' SNAVELY ENTERPRISES, INC. - P.O. BOX 5 - CARUTHERS, CA. 93609 BNAVELY ENTERPRISES~ INC. - P.O. BOX 5 - CARUTHERS~ CA, 9360'3 64.721 S4.720 64.715 SNAVELY ENTERPRISES, INC. - P.O. BOX D - L;ANUl'HERS, CA. 93609 ~4.?~ ~4.?~4 SNAVELY ENTERPRISES, INC. - P.O. BOX 5 - CARUTHERS, SNAVELY ENTERPRISES, INC. - P.O. BOx D - LJANUIHFRS, CA. 93609 '),' i: ;'.; :':;;':.. .' :"- *": * ' ! ¸.ii SNAVELY ENTERPRISES, INC. - P.O. BOX ,5 - CARUTHERS, CA. 'B360'B PACIFIC ~ BELL HAZARDOUS MATERIALS MANAGEMENT PLAN Facility: (SA-004) (BKFD CA-12) 1918~M Street Bakersfield, CA Prepared by: L.B.M.E. CORPORATION 3814 Auburn Blvd. Suite 62 Sacramento, CA 95821 ae B. C. D. E. F. G. TABLE OF CONTENTS Introduction Facility Description ........................... Hazardous Substance Storage Statement .......... Separation of Materials ........................ Monitoring Program Recordkeeping Forms Emergency Equipment Additional Information {Contingency Plan) ...... Page 1 2 3 3 3 3 4 4 APpendix I. o Appendix II. Appendix III. Appendix IV. Hazardous Materials Hazardous Substance (State Registration Inventory Statement Storage Statement Form) Monitoring Program Data Chart for Tank System Tightness Test Inventory Management and Environmental Protection Report Form Hazardous Material Incident Report Form Vicinity and Facility Storage Maps Underground Storage Tank Detail INTRODUCTION This Hazardous Materials Management Plan (HMMP) has been prepared in accordance with the Kern County Ordinance Code ~G3941 regulating the storage of hazardous substances in underground tanks. It pertains to the storage and handling of diesel fuel at the Pacific Bell Main Office at 1918 "M" Street~ Bakersfield, CA 93301. The facility is equipped with a standby power generator which is driven by a diesel fuel fired engine. The fuel is stored in an underground tank with. a nominal capacity of 20,O00-gallons. The generator is normally operated approximately once every month for a duration of one to two hours. This HMMP is designed for the early detection and containment of diesel fuel leaks or spills.. This document has been prepared by Sacramento, California. L.B.M.E. Corporation of Prepared by: Bruce L. Cameron L.B.M.E. Corporation 3814 Auburn Blvd., Suite 62 Sacramento, CA 95821 (916) 972-9010 Reviewed by: James J. Elder vil Engineer .B.M.E. Corporation 3814 Auburn Blvd., Suite 62 Sacramento, CA 95821 (916) 972-90~0 Date -1- FACILITY DESCRIPTION Business Name: Facility Address: Mailing Address: Person Submitting ~Application: Responsible Official on'Site: Emergency Response: Employees: Shifts: Hours of Operation: Uniform Building Code Class: Business Activity: PACIFIC BELL (SA-004) (BKFD CA-12) 1918 M Street, Bakersfield, CA 93301 Sequoia District R. Petree - District Manager 5555 E. Olive, Room B180 Fresno, CA 93762 E.J. Koehler Staff Manager Environmental Management (415) 823-9821 D. Cassidy (805) 327-6043 Pacific Bell Emergency Control Center (415) 823-7777 (24-Hours/day) Abnormal, hazardous, and emergency condi- tions which may affect service, company buildings and/or adverse publicity should be reported to the Emergency Control Cen- ter. This organization maintains the names, home addresses and phone numbers (office and home) of contact persons who are quali- fied and authorized to assist federal, state and local emergency response personnel in the event of an emergency. The center is manned on a 24-hour per day, 7-day per week basis. 3 2: 8:00A~ - 12:00FM Equipment operates continuously. B-2, B-4 Telephone switching center with a standby power generator, a 20,000 gallon under- ground diesel fuel storage tank and associated pipings. -2- De Permits Relating to Hazardous Material Storage from Others: None. Water Table: Not known. EarthquaKe Faults: None known within one mile. Surrounding General Land Uses: See Vicinity Map in Appendix IV Adjacent Properties: North: Twentieth Street; Commercial South: Commercial; Nineteenth Street East: N Street; Commercial; Vacant West: M Street; Commercial Special Land Use: See Vicinity Map in Appendix IV. Facility Storage Map: See Facility Storage Map in Appendix IV. HAZARDOUS SUBSTANCE STORAGE STATEMENT A hazardous substance storage statement for the site was submitted to the California Water Resources Control Board on or befoke July 1, 1984. I% is presented in Appendix I. SEPARATION OF MATERIALS This facility does not store material by type or quantity which requires special separation consideration. The facility was designed to prevent fire or explosion in accordance with applicable, National Fire Prevention Association guidelines and local fire codes. The underground storage tank was provided with a corrosion- resistant coating. The material of construction is compatible with the diesel fuel stored. MONITORING PROGR~ The monitoring program will consist of an "initial" leak test using the "petro-tite" technique followed by in-tank precision product monitoring. Subsequent leak test will De done annually starting within 12 months from the initial leak test. The monitoring program and the initial leak test results are presented in Appendix II. RECORDKEEPING Teletype of computer printouts associated with underground tank monitoring will be reviewed and initialed daily by the responsible Switching Control Center (SCC) person and will De summarized on -3- Form FR-0027. This form is illustrated in Appendix III. The report will be compared with the previous days results to identify any ongoing trends or differences that would indicate' product leakage. Ail visual inspection records and tank monitoring printouts will be filed and retained for a period of three years. Ail recordable leaks and spills will be recorded on a Hazardous Material Incident Report, Form Number FR-0023. This form is also illustrated in Appendix III. EMERGENCY EQUIPMENT A number of registered fire extinguishers are kept on the premises at all times. The location of the emergency equipment is shown on the Vicinity Map and the Facility Storage Map presented in Appendix IV. Additional emergency equipment will be obtained as needed from Pacific Bell contracted hazardous material and The fire extingusihers are maintained and serviced by a State Licensed Pacific Bell Employee (P.M.C.) on a yearly basis. A visual inspection is made by the facility, wardens on a daily basis to ensure the adequacy of the emergency equipment. ADDITIONAL INFORMATION (Contingency Plan) Unauthorized releases (leaks and spills) of petroleum products will be recorded utilizing the Hazardous Material Incident report, Form Number FR-O023 and reported by the operator of the underground storage tank immediately to the following: l) Pacific Bell Emergency Control Center (415) 823-7777 2) Real Estate Department (415) 823-1028 3) Respective upper management within group. 4) Headquarters staff. In instances involving spills, the operator of the underground tank will notify the Kern County Environmental Health Department at (805) 86~-3636 as required by the County Ordinance. In case of fires, the local fire department (9~1) and Pacific Bell Emergency Control Center will be notified promptly, by the operator of the underground tank. -4- In each .step of notification, %o include: good documentation will be prepared Location 2) Specific description and location of the area involved 3) Time and date of occurence 4) Description of spill and type of material 5') Approximate quantity of material that spilled/leaked Ail recordable site. leak and spill records will be maintained on the The key personnel on the site (building warden and all the supervisors) are trained for responding appropriately to any major catastrophe. A training program conducted by the local safety department of Pacific Bell provides the information to the key personnel regarding emergency telephone numbers, reporting requirements, location of emergency equipment, and evacuation procedures. This information is true and c6rrect. If there is any change which would materially affect the Hazardous Materials Management Plan, we will apply for an appropriate amendment. Concur: Approved: M. R. Swan Assistance Staff Manager Local Switching Support R. Petree District. Manager Sequoia District -5- APPENDIX I HAZARDOUS MATERIALS INVENTORY STATEMENT HAZARDOUS SUBSTANCE STORAGE STATEMENT HAZARDOUS MATERIALS INVENTORY STAT~ DATE 10 / 1 / 86 BUSINESS NAME: Pacific Be]l(o=w~c~nn^% ADDRESS: lq18 M Street Bakersfield D.O.T. UN, NA # CHEMICAL NAME / ~N NAME / M.S.D.S.* QUANTITY CLASS OR E.P.A. NAMES IF MIXTURE TRADE NAME (xx) RANGE CL 1993 Diesel 3 * M.S.D.S SHALL BE SUBMITTED IF THE (]qtlMICAL NAME IS NOT GIVEN. Official Reg~strahon Fc California Water Resources Control Board Hazardous Substance Storage Statement .... - =. .... ~,- .:a~,~,. · ,.~.~:- ':. '~,~ ~-,: :' '~'-~, NOTE; ALL UNDERGROUND CONTAtNERS MUST REGISTER EVEN IF STATE AND/OR LOCAL PERMITS ARE IN FORCE. Owner Pacific Bell 370 Third Street Facility Pacific Bell ....... -,,. ,. ....... I ,~,. · .... I" ...... Fue, Sial,on ~ .Ome, ~C -4~00 .......... III 24 Hour Emergency Contact Person I-'. "'-' '. '" .... · ........... -'//,..~--,~23' 77~"" ....... ~' ~-' "- ,' ..... · ..... ,w,..~- ,~3 - Emergency Control C~nter .... ~ ..... ~ ~merqen~ Control Ce,nter 4!3 7.42 COMPLETE THE FOLLOWING ON A SEPARATE FORM FOR EACH CONTAINER I%' Description La~,ocn P4 Or Pond [] , Other Lt,,kt~w f' Yea~ 0+ M'g D Coma nc, Coca: I¢ ~.O,~OCga.ons ~ Un. nown [ E Con;adnet Repa,,s []., None ~'.. Unknown I'I, .- Yes Ye3' Is C2ma.re' eur,ent'~ usedn j~ Yes r- . NO I1 NC yea' O' laS: use -- Does Ine Csmame, S:ore ~Cnec. One', t~ Waste ~. Pfocu¢' .m.,.. Unleaded ~ Re._.:~e, ~ .: P{em,um I~- O,eset ~ .- wasl~. 0,~ [] ~ Olh, e, !est ...... Container Construction Tmc~ness Ot Prmmary Conta,nment __-- E) Gauge ~ Incr,t. 5 [] am ~ Un~.no.,Nn ~ B [] ;: Vau!lr~'': ILocated ,n an underground Vault I I~.. Non vautlo3 ~ .. UnknOwn ; F' Ca,don S;eel r't -- Sla:mess Sleet ~., F,Oergl@ss [q . Polyv,nyi Chloride' [] · Conc~e~e [] ' Sloe, O'.ac [~ . Bronze [] . ComDos,le [] Non-melalhc n ,, Earthen Walls ¢: Un~nown [] ~ Olner E n. RuDDer L,ned m, _ Alkyd L,n,ng [] . Epoxy L,nlng [],,~ PhenOliC bnlng n .. Glass L,r. ng i-' Cla~ um,ng J~' Unt,ncc ~/_ !.~.~.:,~r [],-. dine, __ F [] Poh,¢m..(,rlc Wro;r- v.n,,t ,','r=L; ,"g E] Camo;:,: Pt;',:,': ./,r ,~ , Unbn,'h'.'r, I--~ Nork ~ O?~" ---- VI A As$og~21e3 P~o,ng ~,, A~o,~e G,oun; ~ UqOe~groun~ O. Vau~t(,-~ C P~pmg ReDa,rs ~o, None ~c: U~known ~o~ Ye~ Yea~ of mosl recent ~epa,r Leak Detection ~"'~. V,sual ~ Slock Invenlory [] c~ T~le O~aln I"1 ~ Vapor Sniff We~s ~ ~. ~nso~ ins~umenl ~ G~oun~ Wate~ Mon~lonng We,s ~ P~essu~e ~est ~ ~ Inle~na~ Inspech~n ~o,~, T4~R ~4U~E LEYE~ ~[[] Chemical Composition of Matedal~ Cu~ntly or Prevlousl~ Stored In Unaerground Confiners ~o,~ ,illllllllllll IIl)ll!llllll llllJllllllll IlJllllllllll iS Con'.a,ne~ locate-., cn an Ag',Cu[tura: Farm'~ O0' Yes ~ .. NO IX IMPORTANTI Rea• ,nslruct,ons Del•re s,gn,ng Dist. Staff Mcr. Corrections made by ~o....,,,0.., ,o... o..°. ,.,°.~.,,°. c.,, ,,,,~,-,,. ,~o~.. ~o-l~-~ ~'James Elder, Rgla600 E. J. Koehler FOR STATE USE ONLY APPENDIX II MONITORING PROGRAM DATA CHART FOR TANK SYSTEM TIGHTNESS TEST MONITORING pROGRAM SWITCHING Initial Leak Test An initial testing of the underground fuel storage tanks was conducted by a licensed contractor using the "petro-tite" testing t~chnique to determine container integrity. This testing indicated that the underground fuel storage tank and the underground piping was not leaking. Immediate action will be taken to precision test the underground tank and associated piping should the precision monitoring records indicate a loss or gain of product that cannot be reconciled or presence of other indications that would indicate in all probability that the tank or piping is leaking. Any leakage from the underground tanks or associated piping resulting in soil or water contamination that may be identified during any subsequent leak testing or monitoring will be reported to the Fire Department. Any remedia 1 action required will be accomplished in compliance with the regulatory agency having jurisdiction. The diesel fuel stored at this facility is utilized as an energy source to power "Stand-by Power" electrical generating equipment. As such, the diesel fuel maintained in the underground containers remains in a static state except for monthly.testing of the equipment and times of commercial power interruption. Precision Product Monitoring Because of underground tank orientation and facility staffin~g daily manual inventory control monitoring of the diesel fuel and long term tank monitoring for product leakage will be accomplished with in-tank precision' product monitoring. This will be provided through the installation of the TLS-250 Tank Level Sensor manufactured by Veeder- Root, a subsidiary of Western Pacific Industries Corporation or equivalent. The TLS-250 system consists of a Computerized Inventory Monitor (CIM) and one Digital Sending Probe (DSP) for each tank being monitored. The highly accurate, all-electronic probe has no moving parts fOr greater accuracy and less maintenance than other electromechanical, float-type devices. A single CIM can handle four probes and continuously monitor each one, analyzing their signals for liquid, temperature, depth, and water level. Based on this input, the CIM computes volumes, and stores this information for remote polling. The RS-232C Serial Interface Communications port permits access to TLS-250 information from remote locations via telephone lines.~ This serial interface is capable of handling up to 16 polling stations from centralized remote locations (SCC). The output of the serial port can be formatted for teletype or computer (IBM-PC) interface. The teletype output printout displays formatted reports with spaces and headers on most 72-column printers or CRT .terminals. The computer output gives the information in packed data format (without spaces, carriage returns, etc.) and is the most efficient way to interface ~the CIM. The TLS System has three modes of operation - Leak Detection, Tank Inventory, and Automatic Delivery Reporting. When the leak monitor mode is activated, the TLS System continuously monitors fuel levels in each tank and can detect small losses. An hourly report on each tanks shows temperature-compensated inventory changes to 0.1 gallon based on inventories when the tank leak mode is initiated. An Inventory Loss Alarm feature can initiate a signal to an alarm on the premises, to a security agency or to a central management location when a loss of 25 gallons occurs during any one-hour period. The Leak Monitor is activated through a pushbutton mounted on the front panel, or remotely through the RS-232 Telecommunications Interface. The Tank Inventory Report presents the current status of each tank. It provides station location, date and time, volume of fuel, level of fuel, water level and temperature. The Automatic Delivery Increase Report f~atures are generated two minutes after fuel is delivered to the tank. The printout includes date, time, volume and temperatu£e before and after the increase and the net increase in inventory. Security Code The system is designed to prevent unauthorized use from outside persons by the security code feature. Each site location will be assigned a Security Code in place of the address code. Performance specifications listed below represent values that could be expected from a TLS-250 if a perfectly cylindrical, calibrated (10-foot diameter, 10,000-gallon) tank was used. Height of Fuel at location of DSP - 0.1 inch Volume of Fuel - 15 gallons Leak Detection Mode - 0.1 gallon Fuel Temperature Time - 1-1/2 degrees F - Minutes/Week When the RS-232C serial Interface Communications Port is used, each site location can be queried for' a system status report. This report' checks the system's operational status by transmitting the data, time, whether the leak monitor is on, and whether the inventory loss alarm has been activated. PL~'ASE PHINT Dat hart for Tank System Ti tness Test P.,etro_TL.fe lANK TESTER OWNER Properly tgnk(s) [] 2. OPERATOR 3. REASON FOR TEST (Espla,n Fully) 4. WHO REQUESTED TEST AND WHEN 5. WHO IS PAYING FOR THIS TEST? 6. TANK(S) INVOLVED 7. INSTALLATION DATA Nsme Tills Comolnv. Agency gl IndivlOuil Pe~-o~ ^u'--'~hol~ztns Billing Address Cltv Sl~le Arrant*on of: Olde/ No. Othel Inlrfu~n$ Identdy by Direction Capacity Brand/Supplier Telephone Tirle Telephone Approx. Age Zip Steel/Fiberglass Locatton FILL.UP ARRANGEMENTS Cover Fills ' Verlts Siphones Pumps 8. UNDERGROUND is the wale, over ,he lank WATER Depth to the Water table ............................. [] Yea [] NO Tanks to be filled ~ hr, Date Arranged by Extra product to "top off" and run TSTT. How and who to provide ? Consider NO Lead. Teiminal ot other conlact for notice Of inquiry 10. CONTRACTOR, MECHANICS. any other conttactor involved 11. OTHER I~IFORMATION eR REMARKS Addmonal informal,on off any items above. Officials of others to be advised when testing is in progress or completed. Visitors Or observers present during test etc. 12. TEST RESULTS Tests were mede on the above tank systems in accordance with test procedures presc[ibed for pelto Tff.._e es detailed on ellsched test charts with results SS follows: Tank Identification Tight Le~k__age Indicated Date Tested z~ -2~ ~ .~o.h-. y~ 4. ,,,~. ¢./. tv. ~__-_~:.~, 13. CERTIFICATION Dire This Is to Cm'tlh/that these tank systems were tested on the~) sho~n: ThO~'~}'ndlcated as "Tight" meet ~ criteria established by the N~ltlonel Fire Protection A~ocistlon Pamphlet 329. / / ~ /' . , · 15. TANK TO TEST 1[ CAPACIT~ 17. FILL.UP FOR '~ -mi i 21. TEMPERATURE/VOLUME FACTOR (a) TO TEST THIS TANK lt, TANK MEASUREMENTS FOR. ? TSTT ASSEMBLY .~Tm~mm~,l; C~do~', !__oF l'mduetmTm~__'f Fd~pl~a~amTmc~__'f~ rulm:~D4,~(oef ) · .'-,"'.~. ..................... ,. ~.--~.~.,..~.-~ 1~79' ~+/75 idd~4' I~rLemm . ...... 23. I~m~m~mm~ 20. EXTENSION~OSESETT1NG 2,1. /~e~d~ x_d20'OY72'h~'"., - ~'q~7 ;27m 28. ~b~qm 29. ~ 32. ~. ~ 35. ~_.. 37. ~.~ /~ ~ ~ ..~ //~ ~ Iz~ ~ ~ ~ ~ I ~z.,l&~ .~,~,+./~o~ ~ g j~,/~7 ~.~ ,~o , v~ uv~ .~',./,~ 7,v---{4,,~7 I '/~/~ ~ /~ . ~ e~ ~./~ ~ ~ ~ /~7 -.~7 ~.~ j~ ,V ~ .Fur .&~ ,.,, ~ ,~ l-.,,7 ~.,,~ APPENDI~ III o INVENTORY MANAGEMENT AND ENVIRONMENTAL PROTECTION REPORT o HAZARDOUS MATERIAL INCIDENT REPORT FR 00~7 Ig PACIFICI3BELL. II,em I.I)l 000-098 4 P~-~ T,M, c.,,~ Underground Fuel Storage Tank Inventory Management And Envrionmental Protection Report -- TLS250 Automatic Leak On-Demand Inventory Report Analysis Alerl Report Status Report Readings Job Aid Water Tank Water Intrusion Leak.ge Intrusion Tank Leakage Status Ref)orl Test Test Status Trending Analysis Date Reviewed Was A High W~i A Leak By Water Alarm Alarm Inche~ Temperature Inches Gallons Auto A!er__m_s__ Demand Inventor~ Resul3s_ Indicated? Indicated? ' Of Degress Of Of Hig~ L,ek In. In C~,. Tame. .Required . No Ye~ No Ye~ Water F Fuel Ft/91 w,m Almm .Wfm~ Furl Furl I),a,~, Acliort ' t t , v TI 8 4i - Inc~lte .t- DE(:rNN ,11~ - Conltlm V - M~vVmv · Immedime~,~ncaedition 10 Action... 12 1. Immediately m)tify Real E~tete ..M. an~es~t th~tj~ leak is suspected. A "Petro-Tite ' Tank Test be conducted by Real Estate Management Io valida~r' 13 these findings. 14 . 2. Continued gmduM incmmms M decm~ over ~n ex- 15 tended period (weekly. monthly) a leak ~hould be suspected. Follow procedure~ indicated in step I. 16 171 3. FuM may have been dersvemd during this time frame. If nol. lUSDect a po~ible leak and continue to monitm 18 ..... alo~ely unlil cauM Mn be determined. 19 " ................................ 4. Stlndl~ Ingine rely hive been run during lh~ time frame, tf not, lUSpect I possible leak and continue to ":~0 monitor closely until caur, e can be delermined. E?jPACiFic BELL' NEVADA BELL. Loc.tion Of Release Street City State MateriaIHazard°us Material } QuantityQuantity Released Ill Applicable) Hazardous Material Incident Report IPerson Reporting Incident Name ...... Tel. No. I Date And Time Of Discharge Date Time FR I)023 13,851 IIX:II 019 2'r.~ll Source Of Discharge (i.e., Container, Veh., Facilityl Source Area And/Or Water Body Endangerad Truck No. NA Or UN Code Placard/Label Northern CAL Emergency Control Center (ECC) Agency (Aa Applicable) National Response Center INRC) Office Of Emergency Services IOES) CAL Southern CAL Nevada Weather Conditions (&tS) e2]-7777 818.578-4941 7O2-786-O09O Tel. No. 800-424.8802 8(X)-852-7550 California Highway*Patrol ICHP) CAL Zenith 12(X)0 Department Of Conservation And National Resources I DCNR) NEY 702885-4670 Division Of Emergency Management (DEMI NEV 702-885-5300 Local Agency.lWater Duality Control, Fire Dept., etc. I $ignalure Title ,1 Date ITel. No. ( Pall 2 -- Emergency Conlrol Cenl~.~"$ Copy Extent Of Injuriee, If Any Time Agency Contact Name I, I Data VICINITY AND FACILITY STORAGE MAPS UNDERGROUND STORAGE TANK DETAIL I ~ Ttt 5 T,~EE T CoM ME,'~C~ A L N I co a4 ~'l E ,~ C 20,000-GALLON DIESEL STORAGE TANK (D-79-20K) (r.PfI'ICAL TANK DIAGRAM, ACTUAL NOT AVAILABLE) BASSETT CONSTRUCTION INC. 7730 GREENRIDGE WAY FAIR OAKS, CAUFORNIA 95628 (916) 967-7424 CA UC. #394-896 August 21, 1990 Environmental Health County of Kern 1700 Flower Street Bakersfield, California Attn: Brian 93305 Re: Pacific Bell Sites Dear Brian: We are under contract with Pacific Bell to install Yeeder-Root TLS250i tank gauge and monitoring systems at the sites referenced on the attached page. At the sites where the current installation is a double walled tank, which has an existing piping sump and tank annulus spare, we will install a Veeder-Root sump-annulus monitoring sensor, tied to the main panel for alarm purposes,. should a leak occur. We are also installing a high level alarm 'system for overfill protection. The high level alarm system consists of a series of electrical relays which use an electrical signal from the TLS250i tank gauge to activate a horn and light alarm. Should you have any questions regarding this matter, please do not hesitate to contact our office. Sincerely,. Rex H. Bassett President RHB:cab cc: Lowell Marcus PACIFIC BELL SITES BEING MODIFIED 9th and Jefferson Delano, CA 3501 Columbus Street Bakersfield, CA 3221 South H Street Bakersfield,. CA 1918 M Street Bakersfield, CA 11609 Rosedale Highway Bakersfield, CA 11101 White Lane Bakersfield, CA 8313 E. Segrue Road Lamont, CA Forbes & Payne Streets Edwards A.F.B. Double Walled Tank Double Walled Tank Double Walled Tank Single Walled Tank Double Walled Tank Double Walled Tank Single Walled Tank Single Walled Tank EARTH SCIENCE TECHNOLOGY TEST CERTIFICATE TANK OWNER CONTACT PERSON ADDRESS cITY, STATE TELEPHONE TANK ADDRESS CITY, STATE TEST METHOD TEST DATE Pacific Bell Lowell Marcus 2 North Second Street, Room 575 San Jose, California 95113 ( 408 ) 491-4335 1918 M Street Bakersfield, California Horner Ezy-Chek October 17, 1989 TANK CAPACITY PRODUCT HIGH TEST #331 2,000 Diesel +.0029 LOW TEST The above tank and associated piping system was REMARKS ~ertifi~duct tight. The tank was filled one day prior to the testing date. APP_ROVAL SIGNATURE HORNER EZY-CHEK 1219 WEST IMPERIAL HIGHWAY, SUITE 104, BREA, CALIFORNIA 92621 [] 714-680~8318 EARTH SCIENCE TECHNOLOGY Tank// Sp. Gr. Product temp. 1219 w. IMPERIAL HWY., SUITE 104. BREA, CA 92621 [] 714-680-8318 Product Capacity ,--.~=;:~ Date :, , Coefficient Chart cal. O0~/ Temp. cal 000 Y~g X ~.~Z2~) : ' ? [B) level level gain + x(A) level No. start end loss - x(A) result £ -Jo - ~'& =--,.~ x. r..2o/ ( ~ -~ = ~ x 4z~ -,¢--? : +! = : Tank location Address State Zip. Contact Owner temp. temp. Bain + x(B) temp. start end 10ss - x (B) result final result Certified tight Leak ratepe~, Average FILE CONTENTS INVENTORY B~ermi~ ~o O~er~te ~ /~D~7 Da~ ~ Construct ion Permit ~ Date ~Permit to abandon~ No. of Tanks Date ~ended Permit Conditions ~Permit Application Form, ~Application to Abandon ~Annual Report Forms Tank Sheets tanks(s) Da te []Copy of Written Contract Between Owner & Operator []Inspection Reports [~Correspon~ence- Received 'Da t e Da te Da te []Correspondence - Mailed Da te Date Da te []Unauthorized Release [] Abandonment/Closure []Sampling/Lab Reports []MVF Compliance []STD Compliance []MVF Plan Check [] STD Plan Check []MVF Plan Check []STD Plan Check Reports Reports (New Construction Checklist) Checklist) Check Check (New Construction (New Construction) (New Construction) (Existing Facility) (Existing Facility) []"Incomplete Application" Form []Permit Application Checklist [] Permit Instructions []Discarded []Tightness Test Results Date Da te Da te Data date received and tally of inspection time, []Monitoring Well Construction Data/permits []Environmental Sensitivity Data: [~]Groundwater Drilling, Boring Logs []Location of Water Wells []Statement of Underground Conduits []Plot Plan Featuring All 'Environmentally Sensitive [] Photos Construction Drawings Location []Half sheet showing ri Mi scellaneous etc 1700 Flower Street Bakersfield, California 93305 Telephone (805) 861-3636 KERN COUNTY HEALTH DEPARTML. ENVIRONMENTAL HEALTH DIVISION I NTERI M PERMIT TO OPERATE: HEALTH OFFICER Leon M Hebertson, M.D. UNDERGROUND HAZARDOUS SUBSTANCES STORAGE FACILITY NUMBER OF TANKS= DIRECTOR OF ENVIRONMENTAL HEALTH Vernon S. Reichard PERMI T#1 6002 ISSUED: JULY 1, 1986 EXPIRES: JULY 1, 1989 FACILITY: I OWNER: PACIFIC BELL BKFDCA12/SA004 I PACIFIC BELL 1918 "M" STREET I S?0 THIRD STREET, RM 600G BAKERSFIELD, CA I SAN FRANCISCO, CA 94107 TANK # AGE(IN YRS) SUBSTANCE CODE 0792K '6 MVF 3 NO PRESSURIZED PIPING? NOTE: ALL INTERIM REQUIREMENTS ESTABLISHED BY THE PERMITTING AUTHORITY MUST BE MET DURING THE TERM OF THIS PERMIT NON--TRANSFERABLE * * * POST ON PREMISES DATE PERMIT MAILED: SEP 1 Z 1986 DATE PERMIT CHECK LIST RETURNED: PACIFIC BELL, (BKFDCA12/SAO04) PBI~IT CI~:I~LIST 1918 'M" STREET . FactlltyBAKERSFIELD, CA. Permit 160027C This checklist is provided to ensure that all necessary packet enclosures were received and that the Peraittee has obtained all necessary equipment to implement the first phase of monitorin~ requirements. Please complete this form and return to RCHD in the self-addressed envelope provided within 30 days of receipt. Check: Yes No X × *NOTE: OWNER ADDRESS CHANGE A. The packet I received contained: 1) Cover Letter, Permit Checklist, Interim Pernit, Phase I Interim Permit Nonitoring 'Requirements, Infor~mtion Sheet (A~reement Between Owner and Operator), Chapter 15 (KCOC SG-3941), ExplanatiOn of Substance Codes~ Equipment Lists and Return Envelope. 2) Standard Inventory Control Nonitoring Handbook 3) The Following Forls: a) Inventory Recording Sheet b) Inventory Reconciliation Sheet with stm~ar¥ on reverse c) Trend Analysis Worksheet 4) An Action Chart (to post at facility) S. I have examined the information on my Interim Per. it, Phase I Nonitorin~ Requirements, and Inforlatlon Sheet (A~reement between O~mer and Operator), and find o~ner's na~e and address, facility na~e and address, o~erator's nasa and address., substance codes, and number of tanks to he accurately listed (if 'no' is checked, note appropriate corrections on the back side of this. sheet). X X X X C. I have the followtnz required equipment (as described on pa~e 6 of Handbook): 1).Acceptable ~auglng instrument ~ 2) "Striker plate(s)' tn tank(s} 3) Water-finding paste . D. I have read the information on the enclosed "Infor~ation Sheet" pertaining to Azreements between Owner and Operator and h~reby state that the owner of this facility is the operator (if "no" is checked, attach a copy of azreement between o~ner and operator). I have enclosed a copy of Calibration Charts for a,,ll tanks at this facility (if tanks are Identical, one chart will suffice; label chart(s) with correspondin~ tank ntmbers listed on permit). X F. As required on page 6 of Handbook #UT-10, all meters at this facility have had calibration checks within the last 30 days and were calibrated by a registered device repairman ~f out of tolerance (all, meter calibrations must be recorded on . "Neter Calibration Check Fora" found in the Appendix of Handbook). *X O. Standard Inventory Control Nonitorinz was started at this facility in accordance --~OT~ with procedures described in Handbook #UT-lO. SEE NOTE .Date Started BACK SIDE OF THIS SHEET. ~ ~. .~ .~'~-"-~ ,~ $iKnature o£ Person Completin~ Checklist: ~-///~/~d~/i,~-.~ /\ <, c.~"'~ .... . Title: OPERATIONS STAfF"ADVISOR / LOCAL SWITCHING SUPPORT Date: OCTOBER 6~ 1986 NOTE: OWNER ADDRESS CHANGE PACIFIC BELL 2600 CAMINO RAMON ROOM 2E050 SAN RAMON, CALIFORNIA 94583 NOTE: ON OCTOBER 3, 1986 MALVIN R. SWAN, OF PACIFIC BELL SPOKE WITH MARK PISHINSKY OF THE KERN COUNTY HEALTH DEPARTMENT, TELEPHONE NUMBER 805-861-3636. I EXPLAINED TO MARK THAT UNDERGROUND FUEL TANKS FOR SWITCHING FACILITIES ARE FOR STANDBY POWER ONLY. 'WE PRESENTLY STICK THE TANKS WEEKLY AND LOG THE STICK READING. MARK STATED THAT HIS DEPARTMENT HAS NOT YET COMPLETED THE HANDBOOK (MODIFIED MONITORING), FOR STANDBY POWER. UNTIL THAT HANDBOOK IS AVAILABLE, STICKING WEEKLY AND LOGGING THE STICK READING IS ALL THAT IS NECESSARY, PACIFIC BELL WILL BE IN COMPLIANCE WITH THE KERN COUNTY HEALTH DEPARTMENT MALVIN R. SWAN (415) 823-7729 Kern County Health Depar, Division ot Environmental ..ealth 1700 Flour Street, .Bakersfield, CA 93305 APPLICATION FOR PERMIT TO OPERATE UNDE~GROUI~ HAZ~S SUBSTANCES STYE FACILIT~ Type of Application (check): ~qNe~ Facili6y [']Modification of Facility ~Extsting Facility []~ansfer of Ownershi:-. Emergency 24-Hour Contact (~, area code, phone): Days Pacific Bell Emer~e. ncy Control Nights center (415} 823-7777 Facility Na~ Pacific B?ll Bakersfield Main Office (SA-O04~ "~ o~ Tanks One 7%~5pe of Busines-~ (chec'k). [~lC~ol'i~e 'Statio"' ~Other (describe) Communications · Is Tank(s) Located on an Agricultural Far~? [']Yes Is Tank(s) Used Pri~rily for Agricultural Purposes? Facility Address 1918 'M' Str. eet.,. Bakersfield. Nearest Cross St. 20th Street T R SEC (Rural Lc~ations ~ly) Owner Pacfic Bell "~o0~ ~oo-O, Contact Person E.J. Koehler ;%ddress 2600 Camino Radon, San Ramon . .Zip 94583 Telephon~ <41~. 823-9821 Operator Pacific Bell .. Contact Person D.L. Woods A~dress 3221 S. outh 'H' Street,, .Bk.f.d. Zip 93304 Telephoh'e Water to Facility Provided by City Soil Characteristics at Facility sandy, clay ' Basis for Soil %~pe a~ Grou~water Depth Detenninatt6ns Depth to Groundwater ~50' engineer's estimate Ce Contractor N/A'' Address ~roposed Startin~ Date Worker's Compensation CertifiCation CA O~ntractor's License No. Zip Telephone Proposed C~pletion Dste Insurer D. If ~is Permit Is For Modification Of An E~isting Facility, Briefly Describe Modificatiom Proposed N~A ~, Tank(s) Store (check all that apply): Tank ! %~aste Product Motor Vehicle Unleaded Re~ul.ar Premi~n Diesel Waste uel o-5-rl- [] D D D [] [] [] D [] 0 [] [] 8 [] [] o [] [] o B B Chemical Ccmpesitton of Materials Stored (not necessary for motor vehicle fuels) Tank'~ Chemical Stored (non-co~,ercial name) CAS ! (if'known) Chemical ~reviously Stored (if different) D-79-2K Fuel Oil-used for a standby generator 68476302 Transfer of Ownership Date of ~-'ansfer Previous Facility Name I, N/A Previous Owner mod{fy or terminate the facility upon receiving this ccmpleted form. Tnis form has been c~npleted under penalty' of perjury and to the best of my knowledge true and correct. ~,~ . ELDER ENGIN£ERING Signature ~- ~i!dK_ n~NA WAY Title . . Date CA 95821 SACRAMENTO. accept f~ll'¥ all obl'igati~ns of P~'rmi~ No. __ iSSued ~ . I understand that the Permittin~ Authority may review ant transfer of the Permit ko Operate this ~derground storag~ ii Facility Name Pacific Bell Main Office (SA-004) Permit No. TANK ~ ~-79-2K (FILL OUT SEPARATE FORM FOR EACH TANK) FOR EACH SECTION, CHECK ALL APPROPRIATE BOXES [-]Other (describe) 3. Primary Containment Dste Installed ' Thickness (Inches) 1979 unknown 4. Tank Sec'ondary Contai'r~ent [-~Double-Wall r~synthetic Liner r~other (describe): rlMaterial Thickness (Incbes) 5. Tank Interior Lininc~ '--~'~ber [']Alkyd r']Epoxy I-IPhenolic [']Glass [']Other (describe)': 6. Tank Corrosion Protection Tank is: [2]Vaulted INon-Vaulted I-]Double-Wall msingle-Wall Ta-~Material --~Carbon Steel [-]Stainless Steel r]Polyvinyl Chloride [-IFiberglass-Clad Steel Fiberglass-Reinforced Plastic r~Concrete []Al~in~ []Bronze' ~lUnknown Ca.city (Cml lons) 2,000dP []']Lined Vault mNone Manufacturer unknown [] Unkno~ ~' Manufacturer: Capacity (Gals.) rlclay mt~lin~l i=ltl~kno~ --~Galvanized ~ass-Clad []l~l~thylene W~ap ~lVin¥1 Wrapping []Tar or Asp~lt []unk~ mNone []Other (describe): Cathodic Protection: mNone []']Impressed Current System ~lSacrificial 9~x]e System Describe System & Equit~ent: 7. Leak Detection, Monitorin~, and Interception ' ' ~i 'Tank: []']visUal (vaulted' ~ks only) ' [-]Groundwster Monitorir~' Wmll(s) []Vadose Zone Monitoring Nell(s) U]U-Tube Without Liner ~[~U-Tube with C~npatible Liner Directing Flow to Monitoring Wall(s)* Vapor D~tector* [-ILiquid Level Sensor' ['[Conductivit~ Sensor* [] Pressure Sensor in Annular Space of Double Wall Tank [] Liquid Rstrieval & Inspection From U-Tube, Monitoring Nell or ~t~].arr Sp~c~ []Daily Gauging & Inventory Reconciliation m Periodic Tightness Testing ri None [1 Unknown · Other . .Weekly Gaugin~ and Inventory Reconciliation b. Piping: Flow-Restricting Leak Detector(s) for Pressuriz~c] Pipingw []Monitoring S~p with Race~y []Sealed Concrete Racewsy []Half-Cut Compatible Pipe Raceway [] Synthetic Liner Racm~y ·None [] Unkno~v~ [] Other *Describe ~ & ~odel: 8. Tank Tightness ]~-This Tank Been Tightness Tested? ~Yes []N~ []Unknown 5/24/86__ Results of Test Pass ~sting C~ny unknown []Unknown Date of Last Tightness Test Test Name unkno.wn 9. Tank ~ Ta----n~'Repaired? I-lYes reno Date(s) of Repair(s) Describe Repairs 10. Overfill Protection []Operator Fills, Controls, & Visually Monitors Level []Tape Float Gauge []Float Vent Valves []Auto Shut- Off Controls  Capacitance Sensor []Sealed Fill Box mNone Sunknown Other: List Ma~ & Model Fo~' Above ~ices 11. Piping a. Underground Piping: s- Material unknown Thickness (inches) Std. Di~neter ~l/2"Manufacturer unkhown []Pressure ·Suction []Gravity Approximate Ler~th of Pipe'~ 20'" b. Underground Piping Corrosion Protection : Ce []Galvanized []Fiberglass-Clad []Impressed Current []Sacrificial Anode []Polyethylene Wrap l-[Electrical Isolation [-]Vinyl Wrap []Tar or Asphalt · Unknown []None []Other (describe): Underground Piping, Secondary Containment: I-]Double-Wall [']Synthetic Liner Syste~ mNone []Unknown Application Date 170G Flower Street, Bakersf , CA 93305 APPLICATION FOR PERMIT TO OPERATE UNDERGROUND HAZARDOUS SUBSTANCES STORAGE FACILITY ~.De of Application (check): ~Ne-~ Facility ~lModification of Facility ~Existirg Facility ['~Transfer of O~nershiF A. ~ergency 24-Hour Contact (name, area code, phone): Days ~,/~-; p~c,,~ ,9~c ~'..,,~,~g.~~y c~.r~.c ea.,vT~,e Nights Facility Name E D ! oo No. of Tanks Type of Business~k~.~~ ne Station er. ( escribe)7~coM..~,c~r~ Is Tank(s) Located on an Agricultural Farm? I-lYes No . Is Tank(s) Used Primarily for Agricultural Purposes? ['lYes ~NO Facility A~dress /F/~ '~' sFJ. ~,'F~$;'/FZD Nearest ~ss St. T R SEC (Rural Locations O~ner ~c~,c z~z~ Contact Person ~-, ~? ;~idress %70 ;'~,/~ ~;T. .~.,,,~. _ $,~, ~,,~,~,~ Zip ?~,/oZ Telephone (w/~ .~g,~-~ 7~ Operator' p~c,~c 4~c~_ Contact Person Address Zip B. ~ter to FaciliW Provided by~/~£, ~-7-£~ ~-g~l//d~ De~th to' Ground~mtar Soil (~aracteristics at ~acility · asis for Soil Type and Groundwater Depth Determinations Contractor Address Proposad Starti~ Date Worker's C~mpensation Certification CA Contractor' $ U~nse ~>. Zip Tele[~one P.roposed C~pletion Date Insurer D. If This Permit Is For Modification Of An Existinq Facility, Briefly D~scribe Modifications Proposed E. Tank(s) Store (check all that apply): Tan~ ! ~aste,, Product Motor Vehicle Unleaded Regular Prmi,= Diesel Waste ~ue! -CiT-- Ch~nlcal Omposition of Materials Stored (not necessary for ~tor vmhicle fuels) Tank $ Chemical Stored (non-c~mercial name) CAS ! (if kno~m) Chemical PrevioUsly Stored (if different) G. Transfer of O~nership Date of ~-ansfer Previous Facility l/ame l, Previous o~ner modify or 'tenainete the facility upon receiuin~ this c~apleted form. accept fully all' obligations of Pemit NO. issued to . ! understand that the Pemitting ~uthority may review and transfer .of the Permit to Operate this ~derground storage perjury and to the best of my knowledqe is ·his form has been c~npleted under psnalty, of true and correct. S ig na tut e TANK # ~_~_~ (FILL OUT SEPARATE FORM F , CH TANK) --FOR EACH SECTION, CHECK. ~[.T. APPROPRIATE BOXES H. 1. Tank is: [-]Vaulted ~Non-Vaulted I-]Double-Wall []Single-Wall 2. ~ Material C~rbon Steel [-] Stainless Steel [~ Pulyvinyl Chloride [] Fiberglass-Clad Steel Fiberglass-Reinforced Plastic [] Concrete ~ Aluninum [] Bronze [-~UnkrDwn Other (describe) 3. Primary Containment Dste Installed Thickness (Inches) Capacity (Gallons) Manufacturer 4. Tank Secondary Containment [-~Double-~all [] Synthetic Liner []Lined Vault ~None []Unknown ~lOther (describe): Manufacturer: ~lMaterial Thickness (Inches) Capacity (Gals.) 5. Tank Interior Lining -- bber []Emx¥ []men•lie []Glass []Clay []Unli Unknown ~Other (describe): 6. Tank Corrosion Protection ---~Galvanized -~~---~ass-Clad []Polyethylene Wrap []Vinyl Cathodic Protection:' ~None [[Impressed Current system ~acrl£~c~a& · Describe System & Egui[znent: nterce tlon 7. Leak Detection, __~itori~, and I p '_ ...... . ~. ~nk: ~Visual (vaulted tanks only)._[~Grour~later mo.nl~or~r~ Wail(s) []Vmdose Zone Monitoring Nell(s) lit]Tube Without Liner · ?U -Tube with C~npatible Liner Directin~ Flow to Monitori~ Wall(s) Vapor Detector* [] Liquid Level Sensor II Conductivit~ Sensor* [] Pressure Sensor in Annular Space of Double Wall Tank [] Liquid Fietrieval & Inspection From U-Tube, Monitoring Nell or Annular Space [~Daily Gauging & Inventory Reconciliation []Periodic Tightness Testing O Un wn O . b. Piping: Flow-Restricting Leak Detector(s) for Pressurized Piping [] Monitori~ S~p with ~ace~y [] Sealed Co~crete _Race_~¥ ~.~ . []Half-Cut Compatible Pipe Race~ay l-]Synthetic Liner []unknown []ot r · Describe Make & Model: 8.Tank Tightness ~No []l~known ~-Th-~'T~-~--Been Tightness Tested? C]¥es Date of Last Tightness Test ~esults of Test Testing C~npany Test Name 9. Tank Re~air Tank Repaired?. •'lyes I"11%io ,~Un~wn Date(s) of Repair(s) Describe Repairs 10. Overfill Protection visually Operator Fills, Controls, & Monitors Level Tape F~oat Gauge ~Float Vent Valves [] Auto Shut- Off Controls C apacitance Sensor [']Sealed Fill Box ~None []Unknown Other: List Make & Model Fo~ Above Devices 11. Pipi~ - a. Llnderground piping: ~Yes [~]No []Unknown _ Material Thickness (inches) ' ' Diameter Manufacturer _ []Pressure ~Suc~Gravity '~p---r-~imate Length of Pipe ~ z;~O' b. Underground Pfping Corrosion Protection : []Galvanized []Fiberglass-Clad []Impressed Current []Sacrificial Anode []Polyethylerle Wrap ~Electrical Isolation []Vinyl Wrap []Tar or Asphalt []Unknown ~None []Other (describe): c. Underground Piping, Secondary Contai~nent~ ~, ' []Double-Wall []Synthetic Liner System ~None []Unknown [~Other (describe): Fi C n E F: f~' [:3 H J 1 '! / - .i ~,'"r r')/',-r' A i.~ ~ Ve4JT uP k nm. o~ [] [] [] ! rtTiAL FLOOr~ r~L~ ._ly ._ . FMEI?GE!klGYF. LI.(;.,,ILIE FFOOM Fl, Il .Al?GED P!~._A.!,! ~L.A,I,.J (M,~.t,.JMOLE coVE.r4. / ~/ / ~ M ..~ T/~ ~ E T' .370 'l'b ~.Ld ~.J L ..; Room 600(:; L4,a]'~ £"L',lncl$co, CA 94 LO')' June Kern county Health Department Division o£ Environmental Health t'?O0 Flower Street Bakersfield, CA 93305 Deaf' 5i~' or Madam: please find enc'Losed completed copies of an "Application for ]:'erlnit to Operate Underground Hazardous Substances Storage Facility" [or our £acilit[es located at: 1918 0 8313 1021 3501 0 0 11609 101 3221 M Street, Bakersfield Weed ['arch HW, Bakersfield E. Segrue Rd., Lamont Calit. Street, Oildale Columbus Ave., Bakersfield N/E Corner Payne ~ Forbes, Edwards 9th and Jefferson St., Delano Rosedale, Bakersfield V' street, Bakersfield South H Street, Bakersfield We recognize that conditions could occur requiring the contact ot persons who are quali£ied and authorized to assist emergency respoi~se personnel. Abnormal, hazardous, and emergency conditions which may effect service, Company buildings and/or adverse publicity should be reported to Our Emergency Control Cente~ (ECC} on (818;~ 578-494[. This organization maintains the names, home addresses and phone numbers (office and home) of contact persons who are quali£ied and authorized to assist~ ffederal, State and Local' emergency response personnel in the event ot an emergency. II] you requ].re addl. tiona[ '/ntormation ok have any questions reqard].ng out' Hazardous Materials/Waste ['[ogram, please contact us ol1 (4.15) 542-6'758, o[ (4.1.5) 542-9'732. Sincere l~r, E. ,1. KOEHLER, CHMM ~.'nviron~nental Management ~nc.[osures ¥ -~ ND E ECHNOLOGY, INC. **** CERTIFICATE OF UNDERGROUND STORAGE TANK INTEGRITY **** PRECISION VOLUMETRIC QUANTITATIVE LEAK TEST The following underground storage tank system has been tested and is certified within the allowable limit of NFPA Title 329 at: TWENTY-SEVEN INCHES ABOVE GP~ADE LEVEL. STATION NUMBER TANK NUMBER TANK CAPACITY TANK CONTENTS SITE SA004 D-79-20K 20000 DIESEL 1988 ENviRONMENTAL HEA TANK LOCATION: TANK OWNER: PACIFIC BELL--SITE SAO04 1918 "M" STREET BAKERSFIELD, CA PACIFIC BELL TELEPHONE NDE TECHNOLOGY, INC. is authorized to test and certify this tank by the: COUNTY OF KERN, STATE OF CALIFORNIA. This CERTIFICATION meets the requirements of State Requlations and Guidelines based on National Fire Protection Association 'NFPA Title 329. This certification meets or exceeds certification standards set by the Federal, State, and Local jurisdictional agencies. Certification Date Certification No. Certified Tester Recertification Date Recommended : 09/30/88 : NDE-CT-09/30/88 : HENSLEY BARBOUR : 09/30/89 (TEST TECHNICIAN) Certif~/c~ation Signature: DAISY E. MOSBY' ' DIRECTOR/O/FOPERATIONS NDE TECHNOLOGY, INC. PROPRIETARy NDE TECHNOLOGY, INC. 2909 OREGON CT., B-1 TORRANCE, CA 90503 (213) 212-5244 CAPACITY 20000 GAL STAT # SITE SAO04 TANK # D-7g-20K TEST DATE: 09/30/88 PRECISION UNDERGROUND TANK TESTING RESULT Patent Pending SHORT REPORT FORM @Copyright 1985,1988 PAGE 1 Owner of storage tanks Company Representative Title PACIFIC BELL TELEPHONE HIKE DELLA-ROCCO ENVIRONMENTAL MANAGER 2. Mailing address of owner 3. Phone of owner 4. Station number 5. Location name for tanks Location address for tanks Location phone number Operator of location 2600 CANINO RANON, ROON 2E050 SAN RAMON, CA 94583 SITE SAO04 PACIFIC BELL--SITE SAO04 1918 "N" STREET BAKERSFIELD, CA (805) 327-6043 D. E. CASSIDY 6. Regulatory Agency COUNTY OF KERN, STATE OF CALIFORNIA 7. Tank designation or ID # 8. Date tank was tested 9. Precision test performed Name of testing company Mailing address of testigg company Testing company telephone 10. Technician conducting test Reviewed by 11. Capacity of tank 12. Tank construction material 13. Testing liquid D-79-20K 09/30/88 NDE VPLT CONPUTERIZED TANK LEAK TESTING SYSTEM NDE TECHNOLOGY, INC. 2909 OREGON CT., B-1 TORRANCE, CA 90503 (213) 212-5244 .x~/ HENSLEY BARBOUR( ://~/"~ ~..~? FIBREGLAS DIESEL 14. A test was performed at TWENTY-SEVEN INCHES ABOVE GRADE LEVEL. The system passed with the leak rate shown below. Allowable'leak resolution of instrumentation or allowable change is in accordance with Regulations and Guidelines based on National Fire Protection Association NFPA Title .329. MEASURED NUMERICAL LEAKAGE RATE IS.- (+) 0.013 GALLONS PER HOUR LOSS (+) or GAIN (-). This measurement is withfn the allowable limits established in NFPA 329 for a tight tank or tank system. NDE TECHNOLOGY, INC. PROPRIETARY NDE TECHNOLOGY, INC. 2909 OREGON CT., B-1 TORRANCE, CA 90503 (213) 212-5244 CAP~~CITY 2~0000 GAL STAT # SITE SAO04 TANK # D-79-20K TEST DATE: 09/30/88 PREC SION UNDERGROUND TANK TESTING SHORT REPORT FORM PAGE 2 PRINTOUT OF TANK SYSTEM LEAKAGE RATE DATA Tank Owner - PAC-BELL (BAKERSFIELD) Tank Number - 20K DIESEL Measurement # 44 Date of Test : 09/30/1988 Time of measurement ........... = 18:50:10 Tank Temperature .............. Tank Pressure ................. = Basic Tank Volume ************* = Temperature Correction ******** : Pressure Correction *********** : Corrected Volume **************: 88.3384 Degrees_F. 0.2551 PSI 20000.657 Gallons 259.5'17 Gallons 0.024 Gallons 20260.198 Gallons Leak Rate Calculation Time .... = 01:02:24 Geometry Band ................. 0.000 Gallons/Hour Total Fluid Level ............. 0.0000 Inches Volume Change ................. = Expected Level Change ......... Avg Measured Level Change ..... = Avg Volume Change = Avg Expected Level'~'i~]~] AvgApparent Leak ............. = Avg Apparent Leak Rate ........ = -0.016 Gallons -0.1078 Inches -0.2281 Inches -0.020 Gallons -0.1341 Inches 0.014 Gallons 0.013 Gallons/Hour Patent Pending COMPUTERIZED PLOT OF LEAKAGE RATE DATA NDE TECHNOLOGY, INC. PROPRIETARY NDE TECHNOLOGY, INC. 2909 OREGON CT., B-1 TORRANCE, CA 90503 (213) 212-5244 NDE VPLT COMPUTERIZED PRECISION TEST REPORT - PATENT PENDING GENERAL REPORT FORM - @COPYRIGHT 1985 PAGE 1 1.Owner c,f stc, rage tanks · Cc, mpany representative PAC~:FIC BELL LOWELL MARCUS 2.Mailing address ,:,f c, wner 3. Owner phc, ne number 4. Station number 5..Location name for tanks Lc, cation address for tanks Lc, catic, n ph,z,n~ number Manager or ,:,perator 2 N. SECOND ST, ROOM 675 SAN JOSE, CA. '35113 (4(:)8). 4'31 -4335 ~¢SA -004 PACIFIC BELL ~SA-004 1918 "M" STREET BAKERSFIELD, CA. 93301 JERRY 6REEN 6. Regulatc, ry agency 7. Tank designation or ID~ 8.Date tank was tested 9.Testing company Mailing address Testing company phc, ne 10. Technician certifying tank S~ate Cer~tifica~ic, n Number KERN DIESEL ~ 331 tI) 9 / 28 / 1990 SNAVELY ENTERPRISES INC. 13381 S. HENDERSON CARUTHERS, CA. 'B3609 800 -345 - 1633 ~93-1116 il. Capacity c,f tank 12. Tank construction material 20,000 g a ]. 1 ,:, n s FIBERGLASS 13.Testing liquid DIESEL 14.UNDERGROUND STORAGE TANK .SYSTEM IS CERTI'FiED TIGHT AT PRODUCT HEIGHT EQUAL TO 145" YES Meas,~tred Numerical Leakage Rate is:-.007 Gallons Per Hc, ur [.,:,'ss (+) or Gain ('-).. This measurement is within the allowable limits established in NFPA 329 for a tight tank system. SNAVELY ENTERPRISES, INCORPORATED - 13381 SOUTH HENDERSON P.O. BOX 5 - CARUTHERS, CALIFORNIA 'B360'B - 800-345-1633 System accuracy:O.05gph = pd>O.95/pfa<O.05; O. lOgph= pd>A.99 NDE VPLT COMPUTERIZED PRECISION TEST REPORT - PATENT PENDING GENERAL REPORT FORM - @COPYRIGHT 1985 PAGE 2 1. Capacity of the tank 2(i), 000 c..,. Past o:,ntents DIESEL 3. Testing liquid DIESEL 4. Tank cc, nstructic, n material STEEL 5. a. Tank inclination (degrees) 1 b. Fill pipe inclination (degrees) 6. a. Internal diameter of tank 119 b. ~ Tank bottom to grade level 7. a. Fill pipe internal diameter 4 c. Top of fill pipe to, tank bottom 152 d. Top of fill pipe to grade level 4 8. Air vents 1 9. Type of fill pipe cap CAMLOCK lO.Type c,f pumping system SUB/TURBINE il.Cc, efficient of thermal expansic, n .(')004508 12.Specific~' gravity ' .850 13.Bulk modulus 21G000 14.Vapor recovery system N/A 15.Depth nf groundwater below grade IS.Date tank was topped for testing 17.Time tank was tc, pped fc, r testing 18. Total pfc, duct 1-evel from tank bc, ttom 09/26/1990 BY 17:00 i45 gallons inches inches inches inches inches number i F~ r h e ':.--. iF~che~2 SNAVELY ENTERPRISES, INcoRpoRATED - 13381S. HENDERSON P.O. BOX 5 - CARUTHERS, CALIFORNIA 93609 - 800-345-1633 System acc,iracy:O.OSgph = pd>O.95/pfa<O.05; O.10gph = pal>0.99 NDE VPLT COMPUTERIZED PREOISION TEST REPORT - PATENT PENDING GENERAL REPORT FORM - @COPYRIGHT 1985 PAGE 3 1. General nc, t'es and lc, g entries: UPON ARRIVAL @ 08:00 MET KENT. I TOOK MEASUREMENTS, THEN PROCEEDED WITH SET-UP PROCEDURES. DUE TO THE DEPTH, PRODUCT & OTHER FACTORS I TESTED WITH THE LEVEL I1" BELOW CEMENT SIDEWALK TO ENSURE MAINTAINING BELOW THE MAXIMUM OF 5 P.S.I. ON TANK BOTTOM. PLEASE NOTE THAT THIS SYSTEM HAS TWO SUBMERSIBLE TURBINE ASSEMBLIES INSTALLED WITH APPARENT DIFFERENT PRODUCT LINES, ONE FEEDING DAY TANK ON ROOF OF THE MULTI FLOORED PAC BELL BLDG. THE OTHER FEEDING THE DAY TANK & GENERATOR AT GRADE LEVEL. NEITHER TURBINE SYSTEM HAS A LEAK DETECTOR INSTALLED. AFTER, CALIBRATING I THEN PROCEEDED TO MONITOR LOSS OF .LEVEL DUE THE PRESENCE OF THE TRAPPED VAPOR IN THIS FIBERGLASS TANK AS THE TEMPERATURE OF THIS SYSTEM ALSO COOLED FOR 2 HOURS PRIDE TO CONDUCTING THIS 3 HOUR TEST. 2. Any special procedures other than the NDE Cc, mputerized VPLT Tank Testing Procedures. USED 2 4" RISERS FOR SET-UP, I USED 2 TEMPERATURE HARNESSES ONE IN EACH RESPECTIVE TESTPIPE FOR IMPROVED AVERAGING OF TEMPERATURES. 3. Description c,f any repairs made to, storage tank system prior to or during the test. NONE 4. Describe ,any recommended repairs. ' RECOMMEND INS.TALLATION OF LEAK DETECTOR(S), YES THERE ARE TWO TURBINES. 5. Describe any Significant delays not caused by tester that resulted in delay~ in cc, mpleting the test. NONE added to tank by tester frc, m tester stnrage tanks. 10 GALLONS ADDED TO BLEED AND RAISE ABOVE GRADE. 1(:) GALLONS REMOVED AT END OF TEST. 7. Dc, es tank shc, w evidence of vapor .pockets'? YES. If yes, was nwner advised of prncedures necessary to r e i e a se t h e v a pn r p c, c k e t'7." NO. SNAVELY ENTERPRISES, INCORPORATED - 13381 S. HENDERSON P.O. BOX'5 - CARUTHERS, CALIFORNIA 93~09 - 800-345-1633 Describe quantity nf liquids removed frnm tank or lic4uids System accuracy:O.O5 = pd>¢').'BS/p~a<0.05; 0.10gph = pd>0.99 NDE 'VPLT COMPUTERIZED PRECISION TEST REPORT - PATENT PENDING GENERAL REPORT FORM - @COPYRIGHT 1985 PAGE 4 1. TOTAL TEST CONDUCTION TIME - .~ ~: 05: 09 h c, u r s Leak rate calculation time : a. start : 11:00:35 hc, urs b. e nd : 14: 05: 44 h o u r s (calculated leak rate based on data generated during final hour of precision test.) 2. Fluid level below grade m 3. Height c,f water present in tank inches i n c h e s PIPING PRESSURE TEST - HYDROSTATIC PRESSURE DATA 4. Piping pressure test conducted NO 5. Amount c,f pressure applied to system N/A 6. Amc, unt of pressure drop N/A 7. Elapsed time during test N/A 8. System pass c,r fail N/A psi psi minutes 9. Was turbine pump activated N/A 10.19 full system leakage rates are in excess c,f allc, wable limits, were the c, wners notified ,-,f any additi,z, nal testing pr,_-,cedures necessary to, isc, late leakage to the tank ,z,r tank piping. N/A il. Have these addi:bional testing procedures been completed? N/A 12.Was helium leak pinpc, inting services rec,-,mmended in pinpr, inting lncatinn c,f leak. NO SNAVELY ENTERPRISES~ INCORPORATED - 13381 S. HENDERSON P.O. BOX 5 - CARUTHERS, CALIFORNIA 'B3609 - 80C)-345-1633 System accuracy:O.05 = pd).O.95/pfa<0.05; O.10gph = pd>0.99 NDE VPLT COMPUTERIZED PRECISION TEST ~PORT COMPUTERIZED PRINTOUT AND PLOTS OF PERTINENT LEAK RATE DATE Tank Ouner .................... = P~C-BELL ~S~OO4-B~KERSFIELD Tank Number ................... = 20K DIESEL Measurement ~ ~G Date of measurement = OB/28/1BgO Time of measurement ........... = 14:0S:44 Tank. Temperature .............. Tank Pressure ................. Basic Tank. Uoiume Temperature Correction Pressure Correction **+******** Corrected Volume Stratified Corrected Volume *** Total Fluid Level ........... Fluid Pressure on, Tank Bottom Total TeMperature~Ohango ...... Total Level Change'. ..... 8~.8~13 degrees F. .8286 psi. 20004.70~ Gallons. 232.92~' Gallons. .077 Gallons. 20237.70G ~ellon~. ' 2023B.481 Gallons. 14~.07368 inches. 4.4248 psi -.O1SB~ degrees F. -.B26~2 ~nches. Leak Rate Calculation Time ..... = 01:01:48 Geometry Band ............ . ..... Rate of Temperature Change .... Volume Change ................. Expected Level Change ......... Meamured Level Change ********* Primary Apparent Leak. ********* Primary Apparent Leak Rate **** Strat Volume Change *********** Strat Expected Level Change *** Strat Apparent Leak *****t*.**** Strat Apparent Leak. Rate *****+ ~vg Measured Level Change ..... ~vg Volume Change ............. avg Expected Level Change ..... Avg Apparent Leak ............. Avg Apparent Leal., Rate ........ Avg Strat Volume 'Change ******* Avg Strat Expected Level Change ArQ Strat Apparent Leak ******* Avg Strat Apparent Leak Rate ** -.0008 Gallons/Hour. -.0031B degrees F/Hour. -.0~0 Gallons. -.160~4 inches· -.1~2~ inches~. -.0050 Gallon~. -.005 Gallons/Hour. -.02~.1 Gallons. - 13865 inches. 0010 Gallons. 001 Gallons/Hour. 1~2 ~nches. 0421 Gallons. 22361 inches. 01~2 Gallons. 013 6arlene/Hour. 0567 Gallons. 18960 inches. 00G8 Gallons. 007 Gallons/Hour. / TEST TIME - MINUTES SNAVELY ENTERPRISES, INC. - P.O. BOX 5 - CARUTHERS, CA. 'B360'B NDE VPL.,,T ,~0MpUTERIZED PRECISION TES,T REPORT COMPUTERIZED PR~INTOUT AND PLOTS OF PERTINENT LEAk: RATE DATE Comoute~ized Plot G_i Ave~oe _Temperature Computerized Plot D_~ Liquid. Level SNAVELY ENTERPRISES, INC. - P.O. 'BOX 5 - CARUTHERS, CA. 93609 Computerized Plot Of T.e~pera.t,4re Sensor. #1 :32 ~'' / · :,.'~ ,IE:[T TII1E ,- PIIHUTE$ SNAVELY ENTERPRISES, INC. - P.O. BOX 5 - CARUTHERS, CA. 936C)'~ NDE VPLT MPUT,E. RIZED PRECISION T~S,T P..ORT COMPUTERIZED PRINTOUT AND PLOTS OF PERTINENT LEAK RATE DATE Cpmputerized Plot Of Temper&tur, e #__~4 Computerized Plot Of Temperature ~5 SNAVi 87.81 TE?:T rlr~£ - r'~ItfUTE:-~ COMPUTERIZED PRINTOUT AND PLOTS OF PERTINENT LEAK RATE DATE l // / TE~:T TIME - MIt. lUTES SNAVELY ENTERPRISES, INC. - P.O. BOX 5 - CARUTHERS, CA. 93609 OAU ~l (channels DBU ~2 (channels 08U ~3 (channels O~W ~4 (channels For Tank ~I 0 - 2B) is present. 30 - S8) is NOT present. 80 - 8B) is NOT present. BO - ;lB) is NOT present. Line Sensor Channel Calibration or Model ~ Height 1 Tamp ~1 0 ¢G0440001 '2 Tamp ~2 S 480440001 3 Tamp ~3 1 4B0440001 4 Tamp ~4 B 480440001 S Tamp ~S ~ .460440001 B Tamp ~8 7 480~40001 7 Tamp ~7 3 4B0440001 8 Tamp ~8 8 4G0440001 9 Tamp ~B 4 480440001 10 Tank Press 20 4,80 Volts/psi 12 Leval ~ 10.00 Volts/inch Na~e of Fluid ~ OIESEL 24.0000 'inches 33.0000 inches 42.0000 inches S1.0000 inches 60.0000 inches 8B.0000 inches 78.0000 inches 87.0000 inches B6.0000 inches Specific Gravity of Fluid = .850 Thermal Coef of Expansion = .0004S08 Bulk Modulus of fluid = 216000.0 Oisplacement Calibration Volume = 800.0000 Milliliters = 56.61¢2 cubic inches. Tank Level Readings: -}1.478913 volts, = -1.147B inches Tank Level Readings: -J.057030 volts, = -.3057 inches Calibration Factors Displacement Ca'libration Volume = Primary Initial~fluid l~vel = Primary Final fluid level = Primary fluid level change = 38.G14£S cubic inches -I.14789 inches. -.305'70 inches. .84218 inches. Processing Tank Number 1 Data Point Number ¢ OAU ~i (channels 0 - 28) is present. O~U ~2 /channels 30 - 58) is NOT present. O~U ~3 (channels 80 - 88) is NOT present. D~U ~4. (channels 80 - 119) is NOT present. Tank Pressure Transducer Voltage = 3.4394 volts Tmp~ I Ch~ 0 Tmp~ 2 Ch¢ B Tmp~ 3 Ch~ 1 Tmp~ 4 Ch~ 6 Tmp¢ S Ch~ 2 TMp¢ G Ch~ ? Tmp~ ? Ch~ 3 Tmp~ 8 Ch~ 8 Tmp~ 9 -Ch~ 4 R = 4374.80 ohm, tmp= 82.S380 F R = 4342.30 ohm, tmp = 82.8497 F R = 4188.80 ohm, tmp= 80.S789 F R = 4878.48 ohm, tmp= 85.5037 F R = 3947.20 ohm, tmp= 86.8652 F R = 3859.70 ohm, tmp= 87.8164 F R = '3937.98 ohm, tmp= 86.36S2 F R = 3839.70 ohm, tmp= R = 3891.60 ohm, imp = 13.781850 volts, = Tank Level Readings: ht = ~4.00 ht = 33.00 ht = hi = Sl.~8 ht = 88.00 ht = 89.00 ht = 78~.00 87.00 88.0373 F, ht = 87.4688 F, ht = 1.3762 inches T~NK LEGK TEST RROGRGM Oisc Number 412013 NDE Environmental Corp. Copyright 1986-1990 All rights reserved. Tank Owner .................... = P~C-BELL ~SA004-B~KERSFIELD Tank Number ................... = 20k DIESEL ~331 Measurement ~ 0 Date of measurement = 09/28/1990 Time of measurement ........... Tank, Temperature .............. Tank. Pressure ................. Temperature Correction ******** Pressure Cotter'lion *********%, Stratified Corrected Volume *** Total Flu-id Level ............. Fluid Pressure on Tank. BottOm = 11:00:35 85.8489 degrees F. .8S99 psi. 20004.70S Gallons. 233.065 Gallons. .080 Gallon~. 20237.849 Gallons. 20236.B98 Gallons. 145.00009 inches. 4.45~0 psi Processing'Tank Number 1 Oats Point Number ,=nk. Pressure Transducer Voltage = 3.'433 volts Tmp~ 1 Ch~ Tmp~ 2, Ch~ TMp~ 3, Ch~ Tmp~ 4, Ch~ Tmp~ S, Ch~ Tmp~ B, Ch~ 'Tmp~ ?, Ch~ Tmp~ 8,'Ch~ Tmp~ 9', Ch~ 0 R = S R = I R = 6 R = 2 .R = 7 R = 3 R = 8 R = 4 R = Tank Level Readings: 4375.50 ohm, tap = 4342.60 Ohm 4167.38 ohm 4075.50 ohm 3947.20 ohm 3859,80' ohm 5938.60 ohm 3839.40 ohm 3891.90 ohm 13 ~ ~ volt; .449~50 tmp tmp= 84.5748 F tmp= 85.5138 F tmp= 86.8B52 F tmp= 87.8175 F imp = 86.9S76 F tmp= 88.0400 F tmp= 87.4636 F , = 1.3249 inches 82.5515 F, ht = 82.8468 F, ht = 2:.00 hi = 42.00 ht = 51.80 ht = 80.00 ht = 69.00 ht = ht = S7.~0 ht = 96.00 TANK LEAK TEST PROGRAM Disc Number 412013 NDE Environmental Corp. Copyright 1986-1980 All rights reserved. Tank Owner .................... = PAC-BELL gSAOO4-BAKERSFIELB Tank'Number ................... = 20K OIESEL ~531 Measurement ~ 1 Date o¢ measurement = 09/£8/1990 Time of Measurement ........... = 11:05:39 Tank. Temperature .............. = 85.8458 Tank Pressure ................. = .8585 Basic Tank Volume +************ = Z0004.'705 Temperature Correction ******** = 233.055 Pressure Correction *********** = ,079 Corrected Volume ************** = £0237.838 Stratified Corrected Volume *** = 20236.580 Total Fluid Level ............. = Fluid Pressure o'n Tank, Bottom = Total T~mperatur~ Change, . ..... = 'Total Lave! Change ............ = Leak Rate Calculation Time ..... : 00:85:04 Geometry Band = Rate of Temperature Change .... = ',,'o I ume Change ............. ' .... = Expected Level Change ......... = Measured Level Change ******~** = Primary Apparent Leak ********* = ¢rzmary Apparent Leak. Rate **** = Strat Volume Change *********** = Strat Expected Level Change *** = Strat Apparent Leal. ****.~.i****, = Stra~ ~ppar'ent Leak. Ra~e ****** = degrees F. psi. Gallons. Gallons. Gallons. Gallons. Gallons. 144.94874 inches. 4.4514 psi -.001~0 degrees F. -.05125 ~nches. -.0028 Gallons/Hour. -.01537 degrees F/Hour, -.012 GaLlons. -.06~0~ inches. -.~512~ ~nches. -.0022 Gallons, '-.028 Gall.ors/Hour, -.017B Gallons. -,09353 inches, -.0080 Gatlons. -.0~4 Gallons,,'~tour. Total Elapsed Test Time ....... = 00:05:04 ;.] . Processing Tank Number l Bate Point Number Tank Pressure Transducer Voltage = 3.426 volts Tmp~ 1 Tmp~ 2 Tmp~ 3 Tmp~ 4 Tmp~ 5 Tmp~ B Tmp~ 7 Tmp~ 8 Tmp¢ 9 Ch~ 0 R = Ch~ 5 R = Ch~ 1 R = Ch~ B R =. Ch~ 2 R = 7 R .--. Ch~ 3 R = Ch~ 8 R = Ch~ 4 R = Tank Level Readings: 407B 30 ohm 3859 BO'ohm 5358 80 ohm 3840 30 ohm 3891 ?0 ohm imp = 82.S342 F, ht = 24.98 imp = 82.87S7 ~, ht = 35.8~ tmp= 84.S8¢7 F, ht = 42.08 imp = 85.50~7 F, ht = 51.80 imp = 8G.8S23 F,'ht = 60.80 imp = 87.8142 F, ht = 69.88 imp = 86.9SSS F, ht = ?8.8'8 imp = 88.¢586 F, ht = '87.08 imp = 87,465? F, ht = 96.80 1.£894 inches 12.89~590 volts, = TANK LEAK TEST PROGRAM Disc Number NOE Environmental Corp. Copyright 1'988-1890 All rights reserved. Tank Owner .................... = P~C-BELL ~SAOO4-BAKERSFIELD Tank. Number ................... = 20K DIESEL Measuremen~ ~ 2 Date o¢ Measurement = 09/28/1990 Time o¢ measurement ........... = lI:10:~3 Tank Temperature .............. = Tank. Pressure ................. = ~asic Tank, Volume ~***~***~**** = Temperature Correct,on ******** = Pressure Correction *********** = Corrected Volume ************** = Stratified Corrected ~Jolume *** = Total Fluid Level ............. = Fluid Pre'saute o,n Tank 8oitom = Total T%mperatur~ Change ...... = Total Level Change ............ = 85,8442 degrees F, .8565 psi. 28004,70S Gallons, 255,848 Gallons, 20237,825 Gallons, 20£3S.572 Gallons. 144.91317 inches. -.¢827! degrees F. -.08683 inches. Leak Rate Calculation Time ..... = 00:18:08 Geometry Band ................. = Rate of Temperature Change .... = Ve~ume Change ................. Expected Level Change ......... = Measured Level Change *****~*** = Pr*imary hpparent Leak. ********* = Primary Apparent Leak Rate **** = otrat Volume Chang~ *********~* = Strat Expected Level Change *** = Strat Apparent Leak ****%~.***** = Stcat Apparent Leak. Rate ****** = - 0029 Gallons/Hour. - 81585 degrees F,'Hour. - 825 Gallons. - 13159 inches. - ~8683 Lnches. - 008~ Gallons. -.050 Ga!lons/H..3ur. -.0259 Gallon~. -.13778 inches. -.0098 Gallons. -.057 Gallon. s/Hour. Total Elapsed Test Time ....... = 00:10:08 Processing Tank. Number 1 Oats Point Number 3 Tank Pressure Transducer Voltage = 3.3969 volts Tmp~ 1 Tmp~ 2 Tmp~ 3 Tmp~ 4 Tmp~ 5 Tmp~ 6 Tmp~ 7 Tmp¢ 8 Tmp~ 9 Ch~ 0 R = Ch¢¢ 5 R = Ch~ 1 R = Ch~ 8 R = Ch~ ~ ~ R = Ch~ 7 R = Ch~ 3 R = Ch~ 8 R = Ch~ 4 R = Tan'k, Level Readings: 4574,80 ohm 4340,10 ohm 4167,70 ohm 4077,48 ohm 584?,40 ohm 3858.98 ohm 3939.80 ohm 3839.~ ohm 3892.80 ohm imp = 82 5399 F imp = 82 8709 F imp = 84 S708 F imp = 85 4933 F imp = 86 8631 F imp = 87 8£52 F tmp= 86 9469 F imp = 88 8486 F imp = 87 4559 F :. 1 .~369 inches ~.368633 volt ht = ht : ht : ht : ht : ht : ht : ht : ht : 24.~0 4£.~0 S! 00 60 00 98 00 TANK LEAK TEST PROGRam Oisc Number 412015 NDE Environmental Corp. Copyright 1986-1990 ~11 rights reserved. Tank Owner .................... : PAC-BELL ~S~004-B~KERSFIELD Tank· Number .................... = 20K DIESEL ~331 Measurement ~ 3 Date of measurement = 09/£.8/1990 T~me of measurement ........... = 11:15:49 Tank Temperature .............. = Tank. Pressure ................. = Temperature Correction ******** = Pressure Correction ~********** = Corrected Volume ************** = StratifieO Corrected Volume *** = Total Fluid Level ............. = Fluid Pressure on'T~nk. Bottom = Total Temperature ~hange ...... = Total Level Change ............ = 85,8452 degrees F. .8492 psi, 20004.705 Ga!lens. 233,049 Gallons. .079 Gallons. 20237.833 Gallons% 20238.575 Gallons. I&4,8~OSS inches. 4,448? p~i -,00173 degrees F. · -,I~932 inches, Leak Rate Calculation Time ..... = 00:15:1~ Geometry Band ................. Rate of Temperature Change .... Volume Change ................. Expected Le~el Change ......... Measured Level Change ********* Primary ~pparent Leal,: ********* Primary ~pparen't Lea[:: Rate **** Strat Volume Change *********** Strat E,~p~cted Level Change *~* Strat 6pparent Leak *****~*** Sirs( hpparent Leak, Rate ****** Avg Measured Level Change ..... 6vg Volume Change ............. 5vg Expected Level Change ..... ~vg'Gpparent Leak ............. Avg Apparent Leak Rate ........ ~vg Sinai Volume 'Change ******* 6vg Sinai Expected Level Change 5vg Strat ~pparent Leak, ******* Avg Strat ~pparent Leak, Rate ** -,0012 Gallons/Hour. -.00680 degrees F/Hour, -.017 !Sailons. -,08794 inches. -.13932 ~nches, ,0097 Gallons, ,038 Gallons/Hour. - ~ Gallons, '- 11968 inches, 0037 Gallons. 015 Gallons/Hour. - 06684 inches, - 01t8 Gallons, - 062G8 inches. 0008 Gallons, 006 .Gallons/Hour. - 0152 Gallons. - 0?022 inches. ~ 0006 Gallons, - 005 Gallons/Hour, F,::,tal Elap:~ed TesL 'rime ....... : 00:15:1¢ Processing Tank Number I Data Point Number 4 Tank. Pressure Transducer Uoltage = 3.3889 volts Tmp~~ ~ Tmp~' 3 Tmp~ 4 Tmp~ S Tmp~ 6 Tmp~ 7 Tmp~ 8 Tmp~ 9 Ch~ 0 R = Ch~ S R = Ch~ 1 R = Ch~ 6 R = Ch~ 2 R = Ch~ ? R = Ch~ 3 R ' = Ch~ 8 R = Ch~ 4 R = Tank Level Readings: -4575.40 ohm 4540.90 ohm 41G?.SO ohm 4076 90 ohm 3947 90 ohm 3858 80 ohm 3939 00 ohm 3841 30 ohm 3892 40 ohm tmp imp = imp = tMp = imp = imp =. imp = imp = .imp = oi S~z, F, ht = 82 8632 F 84 5728 F 85 4985 F 86 8577 F 87 8285 F 86 3533 F 88 0198 F 87.4581 F 1.1928 inches 11.328333 volts, = TANK LEAK TEST PROGRAM Disc Number NDE Environmental Corp. Copyright 1986-1990 ~i1 rights reserved. Tank'Owner .................... = PAC-BELL ~S~004-BAKERSFIELD Tank. Number ................... = 20K OlESEL ~331 Measurement ~ Date of measurement = 09/£811990 T2me of measurement ........... = Tank. Temperature .............. Tank Pressure ................. B~sic Tank. Volume Temperature Correction ******** Rressure Coprectio~ ****~****** Corrected Volume Stratified Corrected Uolume *** Total Fluid Level ............. Fluid Pressure on Tank Bottom Total Temperature ~hange ., ..... Total Level Change ............ 85.3427 degrees F. .8452 psi. 20004.705 Gallons. ~.02G Gallons. .078 ,~1 ~.ons . ~0~J~.810 Gallons. 20238.553 Gallons. 144.81685 inches. 4.4474 psi -.90424 degrees F. -.1855S ~nches. Leak Rate Calculation Time ..... = 00"~:22.~ Geometry Band ................. Rate of Temperature Change .... Volume Change ................. Expected Level Change ......... Measured Level Change ********* Primary Apparent Leak ********* Primary Apparent Leak Rate **** Strat Volume Change *********** Strat Expec'ted Level Change .*** Strat 8pparent Leak ******~*** Strat ~pparent Leak Rate ****** Avg Measured Level Change ..... Avg Volume Change ............. Avg Expected Level Change ..... Avg Apparent Leak .............. Avg Apparent Leal,: Rate ........ Avg Strat Volume Change ******* Avg Strat Expected Level Change hvg Strat Apparent Leak. ******* Avg Strat Apparent Leak, Rate ** --.0025 Gal[ons,'H,sur. -.012~9 degrees F.:Hc, ur. -.040 Gallons. .~1034 inches. -.18~J5 inches. -.0051 Gallons. -.015 Gallons/Hour. -.0444 Gallons. - 2557G inches. - 0099 Gallons. - 029 Gallons/Hour. - 0904? inches. - 0148 Gallons. - 07845 inches. 0025 Gallons. 013 Gallons/Hour. - O1G4 Gallons. -.08?30 inches. .000G Gallons. .004 Gallons/Hour. Total Elapsed Test Time = 00:20 Processing Tank. Number 1 Data Point Number 5 Tank Pressure Transducer Voltage = 3,3914 volts Tmp~ 1 Tmp~= ~ Tmp~ 3 Tmp~ 4 Tmp~ 5 Tmp~ 6 Tmp~ 7 Tmp~ 8 Tmp~ 9 Ch~t 0 R = Ch~ S R : Ch~ I R' = Ch~ 6 R = Ch¢ 2 R = Ch~ ? R : Ch~ 3 R : Ch~ 8 R = Ch~ 4 R = Tank'Level Readings: !575.30 ohm 4339.38 ohm 4167.10 ohm 4877.28 ohm 3948.88 ohm 3868.48 ohm ~mp = imp = ~mp = imp = tmp = imp 3939.60 ohm, tmp= 3839.70 oh'm, tmp= 3891.60 ohm, tmp= 11.337487 volts, = S2.S333 F 82.8786 F 84.5768 F 85.49S4 F 36.8586 F 87,8887 F 86,3469 F 8S,0375 F ht = 24,88 ht = 33,00 ht = ht = SI,80 ht = ht = ht = 78,00 ht = 87,80 96.~0 87.4688 F, ht = 1.1337 inches T~NK LE~K TEST PROGRSM Oisc NumOer 41£015 NDE Environmental Corp. Copyright 1986-t998 ~11 rights reserved. Tank Owner .................... = P~C-BELL ~SAOO4-88KERSFIELB Tank· Number ................... = 20K OIESEL ~55! Measurement ~ S Oate of measurement = 09/28/1~88 Time of measurement ........... : 11:26:13 Tank Temperature .............. = Tank Pressure ............ ~ .... = ~as~c Tank. Voiume ~+*~**~***** = Temperature Correction ******** = Corrected Volume ******~******* = S(ratified Corrected Volume *** = Total Fluid Level ............. = Fluid Pressure on Tank. Bottom = Total Temderature C~ange ...... = Total Level Change ............ = 85,8445 ,8478 ~88~4 705 ~0~¢, 82? 28236 S73 .144 75756 inches. 4,44S6 ps~ -.0~242 degrees F. Leak Rate Calculation Time ..... = 00:25:38 Seometry Band ................. = Rate of Temperature Change .... = Volume Change ................. = Expected Level Change ......... = Measured Level Change ********* = Primary ~pparent Leak ********* = Primary ~pparent Leak Rate ~*** = Strat Volume Change *********** = Strat Expected Level Change *** = Strat 5pparent Leak *******~** = Strat 5pparent Leak Rate ****** = Rvg Measured Level Change ..... = ~vg Volume Change .............. = - 6vg Expected Level Change ..... = 5vg 6pparen~ Leak .............. = 5vg 6ppamen~ Leak Rate ....... . = ~vg Strat Volume Change ******* = 5vg Strat Expected Level Change = 6vg Strat 5pparent Leal,:. ******* = 5vg Strat 6pparent Leak Rate ** = u_grees F, psi. Gallons. Gallons~ Gallons. Gallons. Gallons. -,0010 6al lops/Hour. -,00566 degrees F/Hour, -.¢23 Gallons. -. I~174,: inches. -,,~4~44 inches. .8227 Gallons. .853 Gal 1.ons/Hour . -.0252 6allons. -.13400 inches. .0204 Gallons. .048 Gallons/Hour. -.1 ~696 2riches. -.¢?~4 tnches. -.~797~ &nches. .¢978 Gallons. .033 Gallons/Hour. Total Elapsed Test Time ....... = Processing Ta~nk Number 1 Data Point Number 6 Tank Pressure Transducer goltage = 3.39? volts Tmp~ 1 Tmp~ £ Tmp~ 3 Tmp~ 4 Tmp~ B Tmp~ 6 Tmp~ 7 Tmp~ B Tmp~ 9 Ch~ 0 R : Ch~ B R = Ch~ I R = Ch~; 6 R = Ch~ .2 R :. Ch~ ? R = Ch~ 3 R = Ch~ @ R : Chic 4 R : Tank' Level Readings: 4374.78 ohm 4339.00 ohm 4166.40 ohm 4075.38 ohm 3947.48 ohm ;858.30 ohm 3939.40 ohm 3841.20 ohm 3892.20 ohm imp = imp : imp = tmp.= ~mp = tmp tmp = tmp = tmp = 5390 h, ht : S2 8815 F 84 5839 F 85 5151 F 86 8631 F 87 8318 F 86 9490 F 88 020? F 8?.4603 F 1.0928 i'nches 10.928187 volts, : £4.00 ht : 33.0¢ ht = 42.90 nt : St.O0 ht = 60.00 ht : 69.00 ht = 78..00 ht = 87.09 ht : 98.80 TANK LE~K TEST PROGRAM _ Oisc Number 412015 NDE Environmental Corp. Copyright 198G-1930 All rights rose,fred. Tank. Owner .,.'.: ............... : PAC-BELL ~S~004-BAKERSFIELD Tank. Number ................... = 20K OIESEL ~331 Measurement ~ E Date of measurement : 09/£8/1990 Time of measurement ........... : 11:31:17 Tank. Temperature .............. Tank. Pressure ................. Basic Tank, Temperature Correction **"***** Pressure CoFrect ion Corrected Uolume *~*~*~*~*** Stratified Corrected I,}o~ume *~'* Total Fluzd Level ............. Fluid Pressure on Tan~ Bottom Total Temperature ~%ange .... '.,. Total Love1 Change ............ 89.8494 degrees F. .8493 psi. 20004.709 Gal ion.=~. ~j_,. 087 Gal l'ons. .079 Gallons. aOaJ ~' .871 Gallons. £023~.610 Ga[ions. 144.?16~3 inches. .4,4~ psi .00246 degrees F. Leal.: Rate Calculation Time ..... : 00:30:42 Geometry Band ................. : Rate of Temperature Change .... : Uolume Change ................. = Expected Level Change ......... : Measured Level Change ********* = Primary Apparent Leak ********* = Primary Apparent Leal:: Rate **** : Strat Volume Change *********** = Strat Expected Level Change *** = Strat Apparent Leal;, ******~** : Strat Apparent Leak Rate ****** : Avg Measured Level Change ..... : Avg Uolume Change ............. = Avg Expected Level Change ..... = 6vg Apparent. Lea~ ............... = Avg Apparent Leak Rate ..... .... = Avg Strat Volume C'hange ******* : Avg Strat Expected Level Change = ~vg Strat Apparent Leak ******* : A'vg Strat Apparent Leak. Rate ** : .0009 Gallons/Hour. .00481 degrees F/Hour. .021 Gallons. I1~0 inches. - 28337 inches, 0745 Gallons. 146 Gallons/Hour. 0125 Gallons. 06699 inches. 0859 Gallons. 129' Ga.[~ons/'Hour. - 14277 inches. --.~012 Gallons. -.0062~ inches. .0257 Gallons. .100 Gallons/Hour. -.0034 Gallons. -.01797 inche~. .023~ Gallons, .092 Gallons/Hour, 'Total Elapaed Test Fime ....... = 00:30:42 Processing Tank Number I Oata Point Number ? Tank Pressure Transducer Voltage : 3.3639 volts Tmp~ t, Ch~ Tmp2 2, Ch~ Tmp~ 3, Ch~ Tmp~ 4, Ch~ Tmp~ S, Ch~ Tmp~ B., Ch~ · Tmp~ 7, Ch~ Tmp~ 8, Ch~ Tmp~ 9, Ch~ 0 R = S R = 1 R = 6 R = ~ R = 7 R = 5 R = S R = 4 R = Tank· Level Readings: 4374 90 ohm 4J.~ 70 ohm 4167 88 ohm 4076 80 ohm 3847 50 ohm 38S8 40 ohm 3939 70 ohm 3839 se ohm 38gl 70 ohm tmp tmp = tmp = tmp = tmp = tmp = tmp = tmp = tmp = volts, = ~°~.S3?l F, ht = 82 84S9 F 84 S713 F 85 499S F 88 8620 F 87 8197 c 88 039S F 87 4657 F · ,'o inches ht : ht = ht = SI.O¢ ht = ht = ht = TANk( LESK T.E.ST PROGRGM Dis,: Number il-915 NDE Environmental Corp. Copyright 188~-1990 ~ll rights reserveD. Tank. Owner .................... = PaC-BELL ~S8004-88KERSFiELD Tank Number ................... : 20K DIESEL Measurement ~ 7 Date of measurement .: Time of measurement : 1l:36:~ Tank Temperature ............... = Tank Pressure ................. = Basic Tank Volume **~***~***** = Temperature Correction ******** = Pressure Correction *********** = Oorrected Volume ************** = Stratified Corrected Volume ~'* : Total Fluid Level ............. : Fluid Pressure on ~ank Bottom = Total Temberature Ohange ...... : Total Level Change ............ : 85.8430 degrees F. .8410 psi. 20004.'70S Gallons. 235.029 Gallons. .078 Gallons. 20237.812 Gallons. 20256.565 Gallons. 144.59165 inches. 4.4405 psi -.00591 degrees F. -.40835 inches. Leak Rate Calculation Time ..... = 00:~5:48 Geometry 8and .... ' ............. Rate of Temperature Change .... Volume Change ................. Expected Level Change ......... Measured Level Change *~**~**** Primary 6pparent Leak. ********* Primary Apparent Leak Rate **** Strat Volume Change *********** Strat Expected Level Change *** Strat ~pparent Leak ******~*.*** Strat ~pparent Leak. Rate ****** ~vg Measured Level Change ..... ~vg Volume Change ............. ~vg Expected Level Change ..... Avg ~p.parent Leak ............. ~vg ~pparent Leak Rate ........ ~vg Strat Volume Change ~vg Strat Expected Level Change Avg Strat &pparent Leak. ******* ~vg Strat ~pparent Leak Rate ** - 8012 Gallons/Hour. - 00655 degree5 F..Hour. - 037 Gallons. - 18BBB inches. - 40835 inches. 0398' Gallons. 067 Gallon's/Ho,~r. - 0324 Gatlons. - 17191 inches. 0445 Gallons. .07'5 Gallons/Hour. -.18201 inches. -.00~7 Gallons. -.03014 lnohes. .0286 Gallons. .096 Gallons/Hour, -.00S9 Gallons. -.03121 inches. .8284 Gallons. .09S Gallons/Hour. Total Elapsed Test Time ....... : 00:35:48 Processing Tank Number 1 Oats Point Number 8 Tank Pressure Transducer Voltage = 3.3784 volts Tmp~ 1 Tmp~ 2 Tmp~ 3 Tmp~ ¢ Tmp~ 5 Tmp~ B Tmp~ ? Tmp~ 8 Ch~ 0 R = Ch~ S R = Ch~ .1 R = Ch~ B R = Ch~ 2 R = Ch~ 7 R = Ch~ 5, R = Ch~ 8, R = Tmp~ 8 Ch~ 4, R = Tank' Level Readings: !375.00 ohm,' imp = 4340.88 ohm 4187.10 ohm 4078,80 ohm 3847.70 ohm 3868.8¢ ohm 3938.88 ohm 38~1.40 ohm 3881.80 ohm imp = imp = imp = imp = imp = imp = imp imp 3.238983 volts, °~.884Z F ht = S4.5788 F 89.4999 F S8.8590 F 87.8131 F S8,9555 F 88.0189 F 87.4648 F .9237 ';nches ht = S1.08 ht = 80.90 ht : 89.80 ht = ht : TGNK LEhK TEST PROGRam Ozsc Number 412913 NOE Environmental Corp. Copyright 1956-1390 ~ll rights reserved. Tank Owner .................... : PGC-BELL ~SG804-BGKERSFiELD Tank. Number ........... · ........ = 20K DIESEL Measurement ~ S Oate of measurement = 09/28,"I~90 Tzme of measurement ........... = 11:41'=~.~= Tank Temperature ..... ; ........ : Tank. Pressure ................. : Basic Tank ¢ olume~. ~***~+**~*** = Temperature Correction ******** = P¢essure Correction Corrected Uolume ~****~**~*~'~ = Stratified Corrected Qolume *** = Total Fluid Level ............. = Fluid Pressure on Tank ~ottom = Total Tem~era%ure Change .: .... = Total Level Change ............ 89.845f degrees F. .8448 psi. £0~04.705 6a!!ons. 233.031 Gallons. .078 Gallons. 20237.814 Gallons. 2023B,SBS Gallons.. 144.94791 inches. -.00378 degrees F. -.45249 inches. Leak Rate Calculation Time ..... = 00:48:57 Geometry Band ................. Rate of Temperature Change .... Vo[ume Change ................. Expected Level Change ......... Measured Level Change **~*~*** Primary 8pparent Leal ********* Primary 8pparent Leak Rate **** Strat Uolume Change ~**~****~ Strat Expected Level Change **~ Strat ~pparent Leal ~*~*~-**~ 3trat Rpparent Leak. Rate **~* ~vg Heasured'Level Change ..... ~vg Volume Change ............. ~v§ Expected Level Change', ..... &v~ ~pparent Leak ............. ~vg ~pparent Leak Rate ........ 8vg Strat Volume Change ******* ~vg Strat Expected Level Change 6vg Strat 8pparent Leak. ******* 8vg Strat 8pparent Leak Rate ** -.0010 Gallons/Hour. -.00553 degrees F,"Hour. --.035 Gallons. -.18843 inches. -.~5249 inches. .0497 Gallons. .073 Gallons/Hour. -.0~=9 Gallons. -.17498 inches. .0925 Gallons. .87? Gallons/Hour. - ~18S inches. -,0042 Gallons. -.02250 inches. .0376 Gallons. .110 Gallons/Hour. -.0024 Gallons. -.01259 inches, .0394 Gallons. .lis Gallons/Hour. Total. Elapsed Test Time ....... = 00:40:57 Processing Tank. Number 1 Bats Point Number 9 Tank Pressure Transducer Voltage : 3.3738 volts Tmp~ 1 Ch~ Tmp~ 2, Ch~ Tmp~ 3 Ch~ Tmp~ 4 Ch~ Tmp~ S Ch~ Tmp$ G Ch$ Tmp~ ? Ch~ Tmp~ 8 Ch~ Tmp~ 9 Ch~ 0 R : S R : 1 R : 6 R : 2 R = ? R : 3 R : S, R = ,4, R = "[anF:.'Levet Readings: 437S.30 ohm, tmp: · 4339.00 ohm 4168.00 ohm · 4077.~0 ohm 3947,88 ohm 3858,40 ohm '3938.98 ohm 3849.69 ohm ~o9~.~0 ohm tmp = t~p = tmp = tmp = imp = imp = imp = ·tmp : 8.8S8207 volts, : 82.5333 F ~.°° 8815 F 84.5678 F 85.4954 F 86.8888 F 87.8307 F 8G.9S44 F 88.0275 F S7.459£ F .8858 inches ~4.00 ht = ht = 42.~0 ht = Sl.~ ht = 5~.00 ht = ht : ht : 87.00 ThNK LEGK TEST PROGRRM Oisc Number 412815 NDE Environmental Corp. Copyright 1988-1980 811 rights reserved. Tank Owner '. ................... = P~C-BELL $ShO.04-BAI<ERSFIELD Tank. Number ................... = ZOK DIESEL ~531 Measurement ~ 9 Date of Measurement = 09/28/lg90 · Time of measurement ........... = 11:46:34. Tank Temperature .............. : TanF:. Pressure ................. = Basic Tank VoZume ************* = Temperature Correction ******** = Pressure Correction *********** = Corrected ~olume *~***********'* = Stratified Corrected Volume *** : Total Fluid Level ............. : F~uid Pressure on Tank Bo,:tom = Total Temperature Cqaange ...... = Total Level Change ............ = 85.8455 degrees F. ,843& psz. 2008Z.705 Gallons, 233.053 Gallons, ,078 Gallons, 28237,836 Gallons, 20235,575 Gallons, 1~4,50984 inches, 4,4380 psi -,00130 degrees F, -.49038 inches. Leal,: Rate Calculation Time..... = 0~'*c':°.*¢.~ Geometry Band ................. Rate of Temperature Change .... Uolume Change ................. Expected Level Change ......... Measured Level Change ********* Primary ~pparent LeaF:. ********* Primary ~pparent Leak Rate **~* Strat Volume Change *********** Strat Expected Level Change *** Strat ~pparent Leak.'*******m-~** Strat ~pparent Leak. Rate ****** 6vg Measured Level Change ..... ~vg Volume Change ............. 6vg Expected Level Change ..... ~vg ~pparent LeaF: .............. ~vg ~pparent Leak. Rate ........ ~vg Strat Volume Change ******* ~vg Strat Expected Level Change ~vg Strat ~pparent Leak. ******* ~vg Strat ~pparent Leak. Rate ** -.0003 Gallons/Hour. -.00170 degrees F/'Hour. -.013 G~llons. -,07038 inches, -.4903B inches, ,0790 Gallons, 103 Gallons/Hour, ~¢ Gallons - I1916 inches, 0699 Gallons, 091 Gallons/Hour. - 2S124 inches. - 0028 Gallons. - Ol~SB inches. .0447 Gallons. .llG Gallons/Hour. -.0020 Gallons. -.01079 inches. .~455 Gallons. .118 Gallons/Hour. 00:Z5:59 Elapsed 'rest T:Lme ....... = Processing Tank Number 1 Data Point Number 10 ,onk Pressure Transducer Voltage = 3.5815 volts Tmp~ l l'mp¢ £ Tmp~ 3 Tmp~ 4 Tmp~ S Tmp~ B Tmp~ 7 Tap% 8 Tmp~ 8 Ch~ ¢ R : Ch~ S R = Ch¢; 1 R = Ch~ B R' = Ch~ £ R : Ch~ 7 R : Ch~ E, R = Ch~ 8 R = Ch~ 4 R = Ta'n'k Level Readings: 4375.£0 ohm ¢338.60 ohm 418.?.60 ohm 4875.g0 ohm 3847.88 ohm 3858'.6~ ohm ~8~9.38 ohm ~841.~8 ohm tmp = 82 c .~ .... F tmp : 8'2.8854 F, ht = tmp= 84.5719 F, ht = tmp: 85.5889 F, ht = tmp: 88'.8588 · tmp= 87.8285 F, ht : tmp= 88.9581 · imp = 38 ¢1~ F bt = 87.4570 F, ht = .888£ inches 3892.50 ohm .tmp: 8.85~58 volts, T~NK LEAK TEST PROGRAM Disc Number NDE Environmental Co~p. Copyright 1588-1~50 all rights res~r',ed. Tank Owner .................... = PAC-BELL ~SAOO4-BAKERSFIELD Tank Number ................... = 20K OiESEL Measurement ~ Date'of measurement : Time cf measurement ........... = Tank. Temperature ............ ... : Tank. Pressure ................. : Basic Tank. Volume ************* = Temperature Correction ******-** = Pressure Correction *********** : Corrected Volume ************** = Stratified Corrected Volume ~** = Total Fluid Level ............. = Fluid Pressure on'Tank Bottom = Total Te~pera~ure~Change ...... : Total Level Change ............ = 85.8458 degrees F. .848¢ psi. 20804.785 Gallons. ~J~.OS~ Gallons. .078 Gallons. 20237.837 Gallons. ~0~8.576 iSallons. i4~.&598~ inches. .4.~¢u psi -.8~11~% degrees g. -.5i0~6 inches. Leak. Rate Calculation Time ..... : 80:51:14 Geometry Band ................. : Rate of Temperature Change .... = Volume Change ................. : Expected Lefel Change ......... = Measured Level Change ********* = Primary Apparent Leak ********* = Primary Apparent Leak Rate **** = Strat Volume Change *********** = Strat Expected Level Change *** = Strat Apparent Leak *****~*.**** = Strat Apparent Leak. Rate ****** = Avg Measured Level Change ..... : Avg Volume Change ......... ' .... = Avg Expected Level Change ..... = Avg Apparent Leak .............. = Avg Apparent Leak. Rate ......... = ~vg Strat Volume'Change ******* : Avg Strat Expected Level Change = ~vg Strat 8pparent Leak *****~* = Avg Strat apparent Leak Rate ** = -.0002 Gallons/Hour. -.00133 degrees F/Hour. -.012 Gallons. - 0839! inches. - 51096 inches. 0841 Gallons. 088 Gallons/Hour. - 8218 Gallons. - 118~£ inches. 07~3 .Gallons. 087 Gallons/Hour. - 28088 inches. 0027 Gallons. 01438 inches. 8556 Gallons. 130 Gallons/Hour. 0022 Gallons. 81188 inches. OSSl Gallons. 1~9 Gallons/Hour. '[otal Elapsed Test Time ....... = 00:51:1~ Processing Tank Number 1 Oats Point Number 11 Tank Pressure Transducer Voltage = 5.364 volts Tmp~ 1, Ch~ Tmp~ 2, Ch~ Tmp~ 3 Ch~ Tmp~ 4 Ch~ Tmp~ S Ch~ Tmp~ 6 Ch~ Tmp~ ? Ch~ Tmp~ 8 Ch~ Tmp~ 9 Ch~ 0 R = S R = 1 R = 8 R = 2 R = 7 R = 5 R = 8 R = 4 R = ,Tank'. Level Readings: 4374.90 ohm 4338.98 ohm 4167.40 ohm 4077.90 ohm 3948.10 ohm 386t.30 ohm 3938.90 ohm 3841.00 ohm' 3892.90.ohm tmp = tmp = tmp = tmp = tmp = tmp = tmp = tmp = tmp = 8.319273 volts, = ~ 5371 F 82 8829 F 84 5738 F 85 4923 F 86 8556 F 87 7988 F 88 ~544 F 85 0229 F 97.4525 F .8319 inches ht = 42.00 ht = Sl.OO ht = ~0.~0 ht = ht = ht = T~NK LEGK TEST PROGRhM Oisc Number 412015 NDE Environmental Corp. Copyright 1886-t990 ~11 rights reserved. Tank. Owner .................... = PaC-BELL ~S8004-BaKERSFIELD Tank. Number ................... = 20K OIESEL ~351 Measurement ~ 11 Date of measurement = 09/28/1~90 Time of measurement ........... = 11:5~:54 Tank Temperature ............... Tank Pressure ................. 8asia Tank Volume *******~*** Temperature Correction *~****** Pr&ssure Correction Corrected Volume ************** Stratified Corrected Uoiume Total Fluid Level ............. Fluid Pressure on Tank. Bottom Total Temderature C?,ange ...... Total Level Change ............ 85.8411 degrees g. .8410 psi. 20004.705 Gallons. ~JJ.Ol~ Gallons. .078 Gallons. ~0~J,.795 Gallons. 20238.539 Gallons. ~.4~S/* inches. 4.4383 psi -.00580 degrees F. -.5442G inches. Leak Rate Calculation Time ..... = 00:SB:19 Geometry Sand ................. Rate of Temperature Change .... Volume Change ................. Expected Level Change ......... Measured Level Change ********* Primary ~ppal-ent Leal<. ********* Primary ~pparent Leak. Rate **** Strat Volume Change *********** StrUt Expected Level Change *** Strat ~pparent Leak *******~.*** Strat Epparent Leak. Rate *'***** 6vg Measured Level Change ..... ~vg Volume Change ............. ~vg Expected Level Change ..... 6'vg 6pparent Leak ...... ....... ~vg ~pparent Leak Rate ........ ~vg Strat Volume Change ******* Avg Strat Expected Level Change 6vg Btrat 6pparent Leak. ~vg Ctrat., hpparent Leak. Rate ** -.0011 Gallons/Hour. -.00B18 degrees F'Hour. -.054 Gallons. -.28736 inches. · -.54428 inches. .0483 Gallons. .052 Gallons/Hour. -.0592 Gallons. -.31467 inches. .0432 Gallons. .046 Gallons/Hour. -.38913 inches. -.~118 Gallons. -.0~279 inches. ,0~14 Gallons. .103 Gallons/Hour. -.0117 Gallons. -.06200 inches. .0616 Gallons. .103 Gallons/Hour. Total Elapsed res( Time ....... = 00:56:19 Processing T&nk Numbe. r. 1 Data Point Number Tar, k Pressure Transducer' Voltage = 3.3569 volts Tmp~ 1 Trap= 2 Tmp4~ 3 Tmp~ ¢ Tmp~ S Tmp~ G Tmp~ 7 Tmp~ 8 Tmp~ 9 CbC 0, R Ch~ 5, R = Ch~ 1 R = Ch~ 8, R = Ch~t 2, R = Ch~ 7, Fi = Ch~ 3, R = Ch~ 8, R = Ch~ 4, R = Tank: Level Readings: 4374.~0 ohm 4J~o.80 ohm 4187.18 ohm 407?.20 ohm'. 3947.80 ohm 3859.~8 oh.',, 3838.48 ohm 3841.~0 ohm 3892.5¢ ohm 8.334017 volt , T6NK LE~K TEST PROGRHM Oisc NumPer 4;]~iZ NDE Environmental Corp. Copyright 1~88-1~0 hit rights reserved. Tank Owner .................... = PGC-BELL ~S8004-B6KERSFIELD Tank. Number ...' ................ = 20K DIESEL MeasureMent ~ '~ Oata of measurement = 0~/28,/lg80 Time of measurement ........... : 12:01:E~ Tank Temperature .............. Tank. Pressure ................. Basic Tank Uolume **~********** Temperature Correction ******** Pressure Correction Corpected ~olume ************** Stratified Corrected Volume *** Total Fluid Level Fluid Pressure on CanL Bottom Total Temperature Change Total Level[ Change ............. 85.8455 degrees F. .8387 psi. 2~004.705 Gallons. 233.052 Gallons. .078 Gallons. 20237.855 Gallons. 202JG.577 Gallons. I14.45722 inches. 4.4384 p~i -.0~143 degrees F. -.S4Z78 inches. Leak Rate Calcula±ion Time ..... = 01:01:'2~ Geometry Band ................. = Rate of Temperature Change .... = ticlume Change ........ .,. ....... = Expected Level Change ......... = Measured Level Change ********* = Primary ~pparent Leak. ********* : Primary ~pparent Leak Rate **** = Strat Volume Change *********** : Sitar Expected Level Change *~* = Sitar ~pparent Leak. ******~*.*** = Strat 8pparent Leak Rate ****** TM ~vg Measured Level Change ..... = ~vg Volume Change ............. = ~vg Expected Level Change ..... = 6vg 6pparent Leak ............. : 6vg ~pparent Leak Rate ........ : ~vg Strat Uolume Change ~****** = 6vg Strat Expected Level Change = ~vg Strat 6pparent Leak *~***** = Avg Strat 6pparent Leal.,, Rate ** = '-.0003 Gallons/Hour. - 00139 degrees F/Hour. - 015 Gallons. - 07818 inches. - 54278 inches. 0874 Gallons. 085 Gallons/Hour. - 0203 Gallons. - 0783 inches. .0819 Gallons. .080 Gallons/Hour. -.41802 inches. -.0074 Gallons. -.0~08 ~nches. 070~ Gallons. 104 Gallons/Hour. - 00S£ Gallo.ns. - 0¢~14 inches. 0G90 Gallons. 101 Gallons/Hour'. "rot. al ELapGa-';d Test Tt. me ........ = ~1:01:24 Processing Tank Number I Data.Point Number 15 Tank Pressure Transducer Voltage = 3.3B09 volts Tmp~ 1 Tmp~ 2 Tmp~ 3 Tmp$ 4 Tmp~ 5 Tmpl; 8 Tmp~ ? Tmp~ 8 Tmp~ 9 Tank~Level Readings: 4575.70 ohm, ~mp = 4340.70 ohm, tmp= 4167.30 ohm ¢077'.70 ohm 5947.90 ohm 3858.98 ohm 3938.40 ohm 3840.40 ohm 3893.00 ohm tmp = tmp = tmp = t~p = tmp = tmp = tmp: 8.253330'vol'ts, : "-'? SiS~ F ht : o~.8[Si F, ht = 84 S748 c ht = 85 4982 F 86 8577 F 87 8252 F 88 0295 F S7.¢516 F .825~ inches ht = h t ht = ht = ht = ht = Sl.O0 69.00 87.00 TANK .LEEK TEST PROGRam Disc Number 41£~ 3 NDE Environmental Corp. Cop,/right 198B-1990 All rights reser,,'ed. Tank Owner ........ ............ : P~C-BELL ~S500~-BAKERSFIELD Tank. Number ................... = 20K DIESEL Date of measuremen~ : Time of measurement ........... Tank. Temperature .............. : Tank Pressure ................. = Basic Tank Uo!ume ************* = Temperature Correction ~******* = Pressure Correction ~********** = Corrected Volume ************** = Stratified Corrected Volume *** = Total Fluid Level ............. = Fluid Pressure on'Tank. Bottom = Total TeWperature ~hange ...... = Total Level Change' . ........... : 85.842B degrees F. .8402 psi. 20~4.705 Gallons. 026 Gallons .078 Gailon~. ~0~7.809 Gallons. 2023E.54~ Gallons. 144.~gIS inches. ~.~581 psi -.00~31 degrees F. -.SS085 inches. Leak Rate Calculation Time ..... : 01:01:33 Geometry Band ................. Rate of Temperature Change .... Volume Change ................. Expected Level' Change ......... Measured Level Change *******'~* Prtmary ~pparent Leal< *****~*** Primary ~pparent Leak. Rate **** Strat Volume Change ~*****~**** Stra~ Expected Level Chan~e *** Strat 8pparent Leak ******~*** Strat 8pparent Leak Rate ~***** 8vg Measured Level Change ..... 8vg Volume Change ............. 6vg Expected Leve~ Change ..... ~vg hpparent Leak .............. ~vg ~pparent Leak Rate ........ ~vg S'trat Volume Change ******* ~vg Strat Expected Level Change ~tr~t 6pparent Leak. ******* ~vg ~ - 5vg Strat 6pparent Leak Rate ** -.0005 Gallons/Hour. -.082g5 degrees F/Hour -.02~ Gallons. -.15311 inches. -,4~g5~ inches. .065£ Gallons. .064 Gallons/Hour. -.0384 Gallons. -.18352 inches. .0576 Gallons. .086 6aliens/Hour. -.43869 inches. -.0084 Gallons. -.'04461 inches. .0736 Gallons. .09G Gallons/Hour. -.0155 Gallons. -.O?lG4 inches. ,eBBS Gallons. .889 Gallons/Hour. Total. Elapsed Test T(me ....... = (~1:06:3,~] Processing Tank, Number I Bate Point Number t4 Tank Pressure Transducer Voltage = 3.35¢8 volts 'Tmp~ 1 Tmp~ 2 TmpS 3 Taps 4 Tmp~t 8 Tmp~ ? Tmp~ 8 Tmp~ g Ch~ 0 R = Ch~ S R = Ch~ 1 R = Ch¢ B R = ChS 2 R = OhS 7 R = Ch~ 3: R = Ch~ 8, R = Ch~ ¢, R = Tank Level Readings: 4375.08 ohm 4343.4~ Ohm 4167.80 ohm 4078.48 ohm 3948..£0 ohm 3839.10 ohm 393g.10 ohm 3801.40 ohm 3892.80 ohm ·tmp : tmp = tmp : tmp = tmp = tap = tmp = tmp : tap : 7.980737 volts, : 82.33GI F, ht = 82.8391 F, ht = 84.3778 F 85.5837 F 8G.8343 F 87.8238 F 85.9525 F 88.0183 F 87.4337 F inches ht = S'I.¢O ht = ht : ht : 78.00 ht : 87.0~ ht = 86.08 TANK LEAK TEST PROGRBM Oisc Number 412013 NDE'Environmental Corp. Copyright 1986-1g.gO 811 rights reserved. Tank Owner .................... : P~C-BELL ~S~O84-86KERSFiELD Tank Number ................... = 20K DIESEL ~3~1 Measurement ~ Oate of measurement = 88128/1990 Time of measurement ........... : 12:12':18 Tank Temperature .............. = Tank Pressure ................. = Basic'Tank, Volume ************* = Temperature Correction *~****** = Connected Volume ************** = Stratified Corrected Volume *** = Total Fluid Level ............. = Fluid Pressure on ~ank. Bottom : Total Temperature Ohange ...... = Total Level Change ............ = 93.33~9 degrees F, .837G psi. 20804.703 Gallons. 235.001 Gallons. .078 Gallons'. 20237.784 Gallons. 20238.533 Gallons. 144.44~89 inches. 4.4333 psi -.00705 degrees F. -.57711 inches. Leak. Rate Calculation Time ..... : Ol:Ol:ua Geometry 8and ................. : Rate of Temperature Change .... : Volume Change ................. = Expected Level Change ..... · .... = Measured Level Change ********* = Primary Apparent Lea~ ******~** = Primary Apparent Lea~: Rate **** = Strat Volume Change *********** = Strat Expected Level Change *** = Strat Apparent Leak ******~*** = Strat 6pparent Leak. Rate ****** = Avg Measured Lave]. Change .... . = 8vg Volume Change ............. = Avg Expected L. evel Change ..... = ~vg Apparent Leak .............. = Avg Apparent Leak Rate ........ = Avg Strat Volume Change ******* = 6vg Strat Expected Level Chamge = Avg Strat 6pparent Leak. ******* = A'¢g Strat ~ppare~t Leak. Rate ** = -.0008 Gallons/Hour. -.00423 degrees F/Hour, - 041 Gallons. ,~ inches. - 49028 inches. OS14 Gallons. 030 Gallons/Hour. - 03B2 Gallons. - 20813 inches. OS~I Gallons. 032 Gallon.s/Hour. - 453'04 i~ches. - 8188 Gallons. - 10030 inches. 08G~ Gallons, 078 Gallons/Hour. - 0220 Gallons. - 118BB inches. 08~£ Gallons. 07~ Gailons/Houc, Total Elapsed Test [lrne ....... = 01:11 :lO Processing Tank Number 1 Data Foint Number 15 Tank. Pressure Transducer Voltage : ~.JS~, volts Tmp~ 1 Tmp~ 2 Tmp~ 3 Tmp~ 4 Tmp~ 5 Tmp~ 6 Tmp~ ? Tmp.~ B Tmp ~1: FJ Ch~ 5, R = Ch~ I R = CbS 6 R = Ch~ 2 R = OhS 7 R = (]h~ 3 R = Ch~ 8 R = Ch~ ¢ R = Tank Level Readings: 4375.48 ohm 4340.38 ohm 4t67.80 ohm 4877.38 ohm 3861.68 ohm 5841.00 ohm 3892.98 ohm 7.774787 volts tap = tmp = tmp = tmp = ~mp ~mp = tmp = tmp -- tmp 82 S323 F, ht = 82 8888 F, ht = 84 S778 F, ht = 85.4944 F, ht = 86 8566 F, hi = 87 7955 F, hi = ¢Z . Sl 60. ~0 86 9525 Fi hi = .88.02Z9 F, ht = S7.~Q ,7775 inches TaNK LEaK TEST PROGRam Oisc Number 412'315 NDE Environmental Corp. Copyright 1986-19~8 ~lt rights reserved. Tank Owner .................... = PAC-SELL $SAOO4-BAKERSFIELD Tank. Number ................... = 20K DIESEL Measurement ~ IS Date of measurement = Time of measurement ........... = 12:.17:18 · Tank. Temperature .............. = ~nk Pressure = Basic Tank Volume ******~****** = Temperature Correction ********. = Pressure Correction *********** = Corrected Volume ************** = Stratified Corrected Uolume *** = Total Fluid Level ............. = F!uid Pressure on Tank. 8ottom = Total Temperature ~hange ...... = Total Level Change ............ = 85.8393 degrees F. .8388 psi. 20004.705 Gallons. 232.996 Gallons, .078 Gallons. .20237.776 Gallons. ~ ~= S~2 Gallons. 144,40129 inches. 4.454G psi -.08764 degrees F. -.59871 ~nches. Leak Rate Calculation Time ..... = 01:01:.29 Geometry Band ................. = Rate of Temperature Change .... = Volume Change ................. = Expected'Level Ohange ......... = · Measured Level Change ********* = Primary apparent Leak ********* : Primary ~pparent Leak Rate **** = Strat Volume Change **********'* = Sinai Expected Level Change *** = Sirat ~ppareni Leak. ******~**** = Strat appareni Leak Rate ****** = ~vg Measured Level Change ..... = Bvg Volume Change ............. = .Avg Expected Level Change ..... = Rvg Rpparent Leak ............. = ~vg apparent Leak Rate ........ = 6vg Strat Volume Change ******* = 6vg Strat Expected Level Change = ~vg Strat Rppar'ent l_oak. ~******. = ~vg Str'at apparent Leak -.8811 Gallons/Hour. -.80577 degrees F/Hour. -,854 Gallons,' -.28857 inches. -.45~38 inches, ,8321 Gallons, ,~Jl Gallons/Hour, -,0537 Gallons, - 2SS18 inches, ~328 Gallons, (~32 Gallons/Hour, - 47859 inches. - 8306 Gallons. - 16~8~ inches. 0579 Gallons, 0S2 Gallons/Hour, - 8329 Gallons, - 1746? inches, GalJonG/Ho~tr, Processing Tank Number I Data Point Number 1G Tank Pressure Transducer Voltage = 3.3346 volts Tmp~ 1 Tmp~ 2 Tmp~ 3 Tmp~ 4 Tmp~ G Tmp~ ? Tmp~ 8 Tmp~ ~ Ch~ .0, R : 457S.20 ohm Ch~ S, R = 4342.48 ohm OhS 1 R = 4187.20 ohm Ch~ 5, R : 4077.78 ohm Ch~ 2, R : 5848.10 ohm Ch~ 5, R = 3959.10 ohm Ch~ 8, R = 3848.50 ohm Ch~ 4, R = 5885.20 ohm Tank'Level Readings: imp = 82.5342 F, h't : imp : 82.8487 F, ht : imp : 84.5758 F, ht = imp = 85.4882 F, ht = imp = 85.8555 F, ht = imp = 8?.8¢8? F, ht = imp = 86.9825 F, ht = tmp= 88.0385 F, ht : tmp: 87.4484 F, ht : .'?SS5 inches 7.558875 volts, = S1 08 CT TANK LEAK TE=. PROGRAM Disc Number 412013 NOE Environmental Corp'. Copyright 1886-1890 Ali rights reserved. Tank. Owner' . ................... : PAC-BELL ~SAOO4-BAKERSFIELD Tank Number ................... = 20K OZESEL ~331 Measurement ~ 15 Date of measurement : 08/28/1880 Time of measurement ........ ,.. = 12:22:51 Tank Temperature .............. Tank Pressure ................. Basic Tank Volume ~**~'*~***** Temperature Correctlc. n ******** Corrected Volume ~*~'*~'*~** Stratified Corrected Volume *** Total Fluid Level ..... ~ ........ Fluid Pressure on Tank. Bottom Total Tem¢erature C'h, ange ...... Total Level Chaoge ........ ;... 88.8584 degrees F. .8~57 p[i. 20004.708 Gallons. 232.888 Gallons. .077 Gallon~. 20257.770 Gallons. 20£35.B14 Gallons. 144.~7948'inches. -.008S2 degrees F. -.52050 Inche~. Leak Rate Calculation Time ..... = 01:01:53 Geometry Band ................. Rate of Temperature Change .... Volume Cha~ge ................. Expected Level Change ......... Measured Level Change ********* Primary Apparent Leak ********* Primary Apparent Leak. Rate **** Strat Volume Change *********** 8fret Expected Level Change *** Strat Apparent Leak *******~'*** Strat Apparent 'Leak Rate ****** ~Avg Measured Level Change ..... Avg Volume Change ............. Avg Expected Level Change ..... Avg Apparent Le~k .............. Avg Apparent Leak Rate ........ ~vg Strat Volume Change *~***** Avg Strat Expected Level Change ~g Strat ~pparent L~al.:: ~'+****+ 6vg Stra± Apparent Leal Rate '*~ -.0008 Gallo. ns/Hour. -.00~17 degrees F/iqour. -.040 Gallons. .~lOBB inches. -.43725 inches. .04~, Gallons. .042 Gallons/Hour. -.~590 Gallons. -.20710 inches. .0435 Gallons. .042 Gallons/Hour. -.48S85 inches. -.0557 Gallons. -.1885~ inches. .0558 Gallons. .054 Gallons/Hour. -.0377 Gallons. -.20031 inches. .0537 Gallons. .~SZ Tc.:,,;'~J. Elapsed 'Teat l'~me ....... = !31:21 :SB Processing Tank. Number 10ata Point Num0er 17 Tank. Pressure Transducer Voltage = 3.3405 volts Tmpit 1 Tmp~ 2 Tmp~ 3 Tmpit 4 Tmpit ? Tmp2 8 Chit ~D R = Ch~ S R = C hit 1 R = C h ~ 6 R = Chit ,:~ R = Ch~ ? R = uh~ 3 R = Ch~ 8 R : C h,~ 4 R : Tank' Level Readings: 4375 00 ahm 4343 70 ohm 416'7 20 ohm 4875 20 ohm 3948 20 ohm 3860 10 ohm 5~39~40 ohm 3848.70 ohm tmp = imp = tmp = tmp = tmp : tmp = imp : tmp : tmp = 7.Ig1057 'volts, : S2 BEG1 F, ht = ~c'~ 8562 :34 5'758 F, ht ~ 42.9~ E!S Si~ES F, h :36 8545 F, nt = 87 S120 86 9498 c ht = ~" 00 87.4626 F, ht = S6.00 .?Igl inches TANK LEAK TEST PROGRAM Disc Number NDE Environmental Corp. Copyright lgS8-19gO All rights reserved. Tank Owner ................ :... : PAC-BELL ~SAOO4-BAKERSFIELD Tank, Number ......... ~ ......... '= 20K DIESEL it531 Measurement ~ 17 Date of measurement = 0~/28/1990 Time of measurement ........... = ]2:~7:40 Tank. Temperature .............. = Tank Pressure ................. = Basic Tank Volume ************* = Temperature Correction ******** = Pressure Correction *********** = Corrected Volume *~'**~*'****~* = Stratified Corrected Volume ~*'* = Total Fluid Level ............. = Fluid Pressure on Tank Bottom : To%al Temperature ~hange ...... = Total Level Change ............ = 85.8387 degrees F. .8351 psi. 20084.705 6al.ions. ?='? ~91 Gallons .077 Gallons, 20237. 773 Gal Ions. ~0~35.S~ G.~I ions 144.J4~9~ inches. -.OOSZl d~gre~s = -.GSTOS ~nche~. Leah Rate Calculation Time ..... = 01:01:27 Geometry Band .............' .... = Rate of Temperature Change .... = Volume Change ................. = Expected Level Change ......... : Measured Level Change ********* = Primary Apparent Leak. ********* = Primary Apparent Leak Rate **** : Strat Volume Change *********** = Strat Expected Level Change *** =' Strat Apparent Leak ******m.**** = Strat Apparent Leak Rate ~***** : ~vg Measured Level Change ..... : ~vg Volume Change ~ ....... '. .... = ~vg Expected Level Change ..... = Avg Apparent Lea!:. ............. =' 6vg Apparent Leal:: Rate ........ = ~'/g Stpat Volume Change ******~ = F~,~'g Strat, E,~,pected Level (Change = m%,/~ Stca~ r~ppacent Leal::. ~** *'*~* = Avg Strat Apparent Leal.: F,~,uu ** = -,0010 Gallons/Hour. -.00556 degrees F,'Hcun. -.053 Gallons. .~8375 ~nches. - 41464 inches. 0246 Gallons. 024 Gallons/Hour. - 0501 Gallons. - 26607 inches. 0280 Gallons. 027 Gallons/Hour. - 46023 inches. -.043~ Go[ions. -,2306~ ~nches. .0432 Gallons. .042 Gallons/Hour. -,~437 Gallons. --.2320~ inches. .D43~ Gallons. .~2 Gallons/Noun. Total Elap;ed Test 'llime ....... .= 91:,77:05 Processing Tank Number 1 Data Point Number 18 Tank Pressure Transducer Voltage = 3.J~S4 volts Tmp~ 1 Tmp~ 2 Tmp~ 3 Tmp~ 4 'Tmp~ 5 Tmp~ 8 Tmp~ ? Tmp~ 8 Tmp~ 9 ch~ 0, R = 4375.08 ohm Ch~ 5, R : 4342.60 ohm Ch~ 1, R = 4167.20 ohm Ch~ B, R : 48?7.80 ohm Ch~ 2, R = 3948.28 ohm Ch~ 7, R = 3859.40 ohm Ch~ 3, R : 3939.18 ohm Ch~ 8, R = 3848.00 ohm Ch~ 4, .R = 3893.98 ohm Tank Level Readings: tmp = tmp = tmp = tmp = tmp ~ tmp = tMp ~ tmp = 7.153710 volts, = 82.9361F 82.8468 F 84.5758 F 89.¢892 F 86.8'545 F 87.8197 F 86.9523 F 88.0348 F 87.4516 F .7154 inches ht = ht = ht = ht = ht = ht = ht = ht = ht = Si 00 78.00 87.00 98.'2~ T~NK LEAK TEST PROGRBM Oisc Number 41Z~13 NDE Environmental Corp. . Copyright 1986-i998 ~ll rights reserved. Tank Owner .... - ................ = PBC-BELL $SB884-BBKERSFtELD Tank Number ................... = £0K OIESEL ~331 Measurement ~ lB Date of measurement = 09/28/1998 Time o¢ measurement .... · ....... = 1£:32:94 Tank. Temperature .............. = Tank Pressure ................. ' = Basic Tank. Volume ************* = Temperature Correct,on ******** = Pressure CoFrectlon *********** = Corrected Volume ************** = Stratified Corrected Volume *** = Total Fluid Level ............. Fluid Pressure on ,Tank Bottom = Total Tem~perature ~hange ...... = Total Level Change ............ = 8S.8408 degrees F. .8313 psi. 20~04.709 Gallons. 233.882 Gallons. .077 Gallons. 20237.784 Gallons. 20238.530 Gallons. 144.~3~19 inches. 4.&327 psi -.08892 degrees F. -.88881 inches. Leak. Rate Calculati.on Time ..... = 81:01:37 Geometry Band ................. : Rate of Temperature Change .... : 'Volume Change ................. : Expected Level Change ......... : Measured Level Change ********* = Primary 6pparent Leak. ********* = Primary 8pparent Leaf Rate **** = Sinai Volume Change ~********** = Strat Expected Level Change *** = Strat Apparent Leak ******#~*** = Strat Apparent Leak. Rate ****** : Avg Measured Level Change ..... = 6vg Volume Change ............. = Avg Expected Level Change ..... = Avg Apparent Leak .............. = ~vg Apparent Leak. Rate ........ = ~vg Strat Volume Change ******* = 6vg Sinai Expected Level Char, ge = 6vg Sinai ~pparent Leak ******* : ~vg Sinai Apparent Leak. Rate ** = -.8817 Gallon~/Hour. -.88913 degrees F,'H~ur, -.086 Gallons. -.45811 inches. .~.~749 inches. -.0182 Gel. lens. -.015 Ga[1ons/H~ur, -.0808 Gallons. -.42988 inches. -.0897 Gallons. -.00~ Gallons/Hour. -.4358~ inches. -.05~9 Gallons. -.291B4 inches. .0271 Gallons. .028 Gallons/Hour. -.0525 Gallons. --.27911 inches. .OZSS Gallons. .02g Gallons/Hour. Total' Elapsed Test Time ....... : 01:32:18 Processing Tank. Number 1 Data Point Number 19 Tank Pressure Transducer Voltage : 3.~9~ volts Tmp~ 1 Tmp~~ Tmp~ 3 Tmp~ 4 Tmp2 5 Tmp: 8 Tmp~ ? Tmp~ '8 Tmp~ 9 Ch~ 0 R : Ch~ S R : C'h~ 1 R : Ch~ 8 R : Ch~ £ R = Ch~ 7 R : Ch~ 3 R : Ch~ 8 R = Ch~ 4 R : Tank.,Level Readings: 4375.10 ohm 4340.20 ohm 4187.10 ohm 4076.18 ohm 3948.40 ohm 3859.70 ohm 3939.00 ohm 3840.80 ohm 3893.20 ohm tmp .: tmp : tmp = t,mp = tmp = tmp = tmp = tmp : tmp = 6.78'3880 volts, = ~.m° 5352 F ht = 82.8899 F, ht = 84.5768 F~ ht = 85.50G8 F 8~.8523 F 87.8184 F 88.8533 F 88.025l F 87,449'4 F .6784 inches ht = ht = ht : hr,: ht = ht = 80.90 78.00 87.00 98.00 TANK LEAK TEST PROGRAM Disc Number 412013 NDE Environmental Corp, Copyright 1986-1990 All rights reserved., Tank Owner .................... : P~C-BELL ~S6004-B~KERSFIELD Tank. Number ................... : 20K OIESEL ~331 Measurement ~ 19 Date of measurement = 09/28/1990 Time of measurement ........... : ;°:38:07~ Tank Temperature .............. = Tank. Pressure ................. = Basic Tank. Uolume ************* : Temperature Oorrectlon ******** = Pressure Correction *********** Corrected ~olume ************** Stratified Corrected Volume *** = 85 8428 8325 ZOOOa 705 233 028 077 20237 810 20236 degrees F. psi. Gallons. Gallons. Gallons. Gallons. Gallons. Total Fluid Level ............. = 144 30220 inches. Fluid Pressure on Tank. Bottom = 4,~318 Total Temperature CMange ...... = -,00410 degrees F, Total L~vel Change ............ = -.69780 inches. Leak· Rate Calculation Time ..... = 01:01:44 Geometry Band ................. = Rate of Temperature Change .... = Volume Change ................. = Expected Level Change ......... = Measured Level Change ********* = Primary ~ppacent Leak ********* = Primary Apparent Leak Rate **** = Strat Volume Change *********** = Strat Expected Level Change *** : Strat Rpparent Leak. *******ti** = Strat ~pparent Leak Rate ****** = ~vg Measured Level Change ..... : ~vg Volume Change ............. : ~vg~Expected Level Change ..... : ~ivg ~pparent Leak .............. : ~vg ~pparent Leak Rate ........ : Avg Strat Volume Change ******* = Avg S.trat Expected Level Change = hvg Strat Apparent Leak ******* = ~'vg Sinai Apparent Leak. Rate ** = -.0000 Gallons/Hour. -.00019 degrees F/Hour. - 003 Gallons. - 01344 inches. - 28944 inches. 0519 Gallons. 050 Gallons?Hour. - 0180 Gallons. - 09542 inches. 0385 Gal, Ions. 035 Gallons/Hour, - 39583 inches. -.0472 Gallons. -.25089 inches. .0272 Gallons. .027 Gallons/Hour, -.0483 Gallons. .~58~7 inches. .0282 Gallons. .026 Gallons/Hour. Total Eiap~e:] [est T:rqe ....... = 01:3'7:32 Processing Tank Number I Oata Point Number 20 Tank Pressure Transducer Voltage = 3.3297 volts Tmp~ I Ch~ 0 Tmp~ ~ Ch~ S Tmp~ 3 Ch~ Tmp~ 4 Ch~ Tmp~ B Ch~ Tmp~ G Ch~ ? Tmp~ ? Ch~ Tmp~ 8 Ch~ 8 Tmp~ g Ch~ Tank Level Reat R = 4378.10 ohm R = 4343.88 ohm R = 4167.38 ohm R = 4077.18 ohm R = 5~48.40 Ohm R = 5859.88 ohm R = 3939.48 ohm R = 3841.90 ohm R = 3882.90 ohm ings: 8.671287 volt tmp = imp = imp = imp = imp = .imp = imp = imp tm~ = 82 8353 F, ht = 84 S748 F 85 4964 F 86 8823 F 87 8153 F 86 9480 F 88 8.129 F S? 4528 F .6671 inches ht = h± = SI.¢O ht = ht = ht = TGNK LEhK TEST PROGRam Disc Number NDE Environmental 'Corp. Copyright !g8G-1990 6Il.rights reser¥eo. Tank Owner .................... = PGC-BELL ~SAOO4-BGKERSFiELO Tank Number ................... '= 20K DIESEL'~33I Measuremen~ ~ 28 Oa~e of measurement = 09/28/1998 Time of measurement ........... = 12:43:17 Tank. Temperature ........ : ..... Tank Pressure ................. Basic Ta~l::. ~olume ************* Temperature Correction ******** Pressure Correction *********** Corrected Uolume *~************ S(ratified Corrected Uolume Total Fluid Level ............. Fluid Pressure on 'Tank. Bottom · Total Temberature Change ...... Total Level Change ............ 85.8380 degrees F. .8322 psi. 20004.705 Gallons. ~.96G Gallons. .077 Gallons. ~0~J7.748 Gallons· 20238,502 Gallons, 144,29080 inches,, -,01892 degrees F. -,70906 inche~, Leal<. Rate Calculation Time ..... = 01:¢1:45 Geometry Band ................. Rate of Temperature Change .... Uo!ume Change ................. Expected Level Change ......... Measured Level Change **'******* Primary 6pparent Leal:: ******~** Primary 6ppar-ent: I_~ak Rat, c ~.,.*,. Strat Volume Change ***~+****** Strat Expected Level Change *** Strat 6pparent Leak ******~*** Strat 6pparent Leal,:. Rate ****** 6vg Measured Level Change ..... Erg Volume Change ....... ~ ..... 6vg Expected Level Change ..... ~vg ~pparent Leak ............. 6vg 6pparent Leak. Rate ........ ~vg St'rat Volume Change ******* ~vg Strat Expected Level Change ~vg Strat 6pparent Leak. ~****** ~vg Strat Rpparent Leak Rate -.0013 Gallons/Hour. -.00684 degrees F,'Hcur. -.06G Gallons. -.34823 inches. -.25657 inches. -.0!73 Gallons. --.017 GalLons,'Hx, ur'. -.0630 Gallons. - 33475' inches. 0147 Gallons. 014 Gallons/Houn. 35507 inches. 0495 Gallons. 46~8~ ~nches. 0174 Gallons. 017 Gallons/Hour. - 0502 Gallons. - 28848 inches. 0157 Gallons. 018 Gallons/Hour. Total Elapsed Test Time ....... = 01:42:42 , Processing Tank Number 1 Bate Point Number 21 Tank. Pressure Transducer Voltage = 3.33'19 volts Tmp~ 1 Tmp~~ ~ Tmp~ 3 Tmp~ 4 Tmp~ S Tmp~ B Tmp~ 7 Tmp¢ 8 Tmp~ 9 Ch~ 0 R : Ch~ S R : Ch~ I R : Ch2 8 R : Ch~ £ R : Ch~ 7 R : Ch~ 3 R = Ch~ 8 R : Ch~ 4, R = Tank'Level Readings: 4375.00 ohm 4339.40 ohm 4187.=~0 ohm 4876.78 ohm 3948.30 ohm 38S9.30 ohm 3959,S0 ohm tmp = t~p t~p = ~mp tmp = tmp = tmp = 84=.00 ohm, tmp= 3893.20 ohm, tmp= 6.400637 volts, = ~.S3Bi F ~=.877S F 84.575S F ss.sees F 86.8534 F 87.8288 F 88.S480 .F 88.011S F ht = ht = ht = 42.80 ht = S'I.80 ht = ht = 69.08 ht = ht = 98.00 87.4494 F, ht = .6481 inches T&NK LESK TEST PROGRBM Oisc Number 41£013 NDE Environmental Corp. Copyright 198B-199e ~ll rights reserved. Tank Owner .................... = PGC-BELL ~S~OO4-BGKERSFIELD Tank. Number .' .................. = 20K OIESEL ~331 Measurement ~ 21 Date of measurem'ent = 09/28/1~90 Time of measurement ........... = 12:48:28 Tank Temperature .............. = Tank Pressure ................. = Basic Tank 'Jolume -************ = Temperature Correction *,****** = Pressure Correction *********** = Corrected Volume ******~******* = Stratified Corrected Volume *** = Total Fluid Level ............. = Fluid Pressure on Tank Bottom = Total Tem~era%ure ~hange .: .... = Total Leve~ Change ............ = 85.8415 degrees F. .8330 psi. ~0~04 7eS "- s ~j.~16 Bailers. .077 Gallons. ~0~.798 Gallons. 2e235.539 Gallons. 144.28~88 inches.- -.00540 degrees F. -.?jB12 inche.s. Leak Rate Calculation Time ..... = 01:01:54 Geometry Band ................. Rate of Temperature Change .... Volume Change ................. Expected Level Change ......... Measured Levei Change ********* Primary 6ppar'erlt Leal:. ****~**** Primary hpparent Leal: Rate ***~ Strat Volume Change Strat Expected Level Change **? S%rat ~pparent Lea~. *'~'*~**~*.**~ Strat Rpparen~ Leak Rate *~*~"* ~vg Measured Level Change ..... Rvg Volume Change ............. hvg Expected Level Change ..... ~vg Rpparent Leak .............. ~vg ~pparent Leak Rate ........ hvg Strat Volume Change ~***** hvg Stra% Expected Level Change hvg Strat ~pparent Leak hvg S%rat 6pparen~ Leak Rate ** -.0007 Gallons/Hour. -.00398 degrees F/Hour. -.038 Gallons. -.20178 inches. -.2~578 knches. .~083 Ga[tons· .088 Ga[ions/Hour. -.0384 Gallons. -.19335 inches. .~085 Gallons. .010 --.31877 ~nches. --.~491 Gallons. -.26106 ~ncnes. .01eS Gallons. .e10 Gallons/Hour. -.049G Gallons. -.26373 inches. .010e Ge[Ions. .ele Gallons/Hour. Total Elapsed Test TLme ....... = 01:47:53 Processing Tank. Number 1 Data Point Number 22 Tank Pressure Transducer Voltage = ~.3535 volts Tmp~$ 1 Tmp~ 2 Tmp~ 3 TMp~ 4 Tmp~ S Tmp~ 6 TMp~ 7 TMp~ 8 TMp~ g Ch~t 0 R = Ch~ S R = Ch~ 1 R = Ch~t B R = C t-, ~. 2 R = Ch~ ? R = Ch~ 3 R = Ch~ 8 R = Ch~ 4 R = Tan~i. Level Readings: 4375.00 ohm 4342.£0 ohm ~187.10 ohm 4078.10 ohm 3948.50 ohm 3859.10 ohm 5939.10 ohm 3839.70 ohm imp = 82.5361. F, ht = 24.8,3 tmp= 82.8587 F, ht = 35.8~) tMp= 84.5768 F, h~,, = ~'~..~'~"~,: tmP = oS.48Bl c ht = Si.88 imp = S6.SB15 F, ht = ~0.08 tMp= 87.8238 F,.ht TM 69.88 tMp= 8B.gS£3F, ht = 79.00 tMp= 88.03?3 F, ht = 87.80 87.4484 F, ht = gE.we ..Gl42 inches 5883.20 ohm, tMp= TRNK LEAK TEST PROGRGM Disc Number 4!2013 NDE Environmental Corp. Copyright 1986-1990 ~ll rights reserved. Tank Owner .................... = P~C-BELL ~S~004-B~KERSFIELD Tank Number ................... = 20K DIESEL ~331 Measurement ~ 22 Date of Measurement = 09/28/lg90 Time of Measurement ......... '.. = 12:55:~0 Tank. Temperature .............. Tank. Pressure ................. Basic Tank Volume ~************ Temperature Correction ******** Corrected Volume ************** Stratified Corrected Volume *** Total Fluid Level ............. Fluid Pressure on 'Tank Bottom Total Temperature Ohange ...... To(al Levei Change ............ 8S.8403 degrees F. .853¢ psi. 20004.705 Gallons. =~.005 Gallons· .077 Gallons. 20237.788 Gallons. ~0~0.530 Gallons. 144.23804 inches. -.0085g degrees F. -.76186 ~nches. Leal:. Rate Calculation Time ..... = 01:01:51 Geometry Band ................. Rate of Temperature Change .... VOlUMe Change ................. Expected Level Chan~a ......... Measured Level Change ********* Primary ~pparent Leak. ********* Primary 8pparent Leak. Rate **** Strat Volume Change *'********** Strat Expected Level Change *** Strat ~pparent Leal:: ******~**** Strat. hpparent Leak Rate ****** ~vg Measured Level Change ..... 6vg Volume Change ............. Rfg Expected Level Change ..... Avg ~pparent Leak .............. Avg 6pparent Leak Rate ........ 6vg Strat Volume Change ******* ~vg Strat E¢,pected Level Change &~g o,rmt 6pparent Leak ~,***** 6vg Strat 6pparent Leal.: Rate ** -.0010 Gallons/Haut. -.00529 degrees F 'Hour. -.050 ',iai Lor, s. -. 264152 inches. -.2B100 inches· -.0028 Gallons. -.002 GaLlons/Hour. -.04~0 Gallons. ~44al inches. 001~ Gallons. 001 Gal lona/Hour. - 28404 inches. - 0484 Gallo'ha. - 25724 ;nches. 0050 Gallons. 005 Gallons/Hour. --.~488 GalLons. -.25936 inches. .0046 .~05 G~t Ions/Hour. Total Elapsed Test Time ....... = 01:53:05 Processing Tank. Number ] Data Point Number ~=~ Tank Pressure Transducer Voltage = 3.3242 volts TmpS 1, OhS' 0 TmpS 2, ChS S TmpS 3, ChS Tmp¢ 4, ChS Tmp~ 5 OhS Tmp~ 8, Ch~ '? TMp~ 7, Ch~ Tmp~ 8, Ch~ 8 Tmp~ 9, ChS 4 R = 4375.20 ohm R : 4358.50 ohm R = 4167.30 ohm R : 4078.20 ohm R : 5848.40 ohm R = 3939.30 ohm R = 3841.40 ohm R : 3893.20 ohm Tank Level Readings: trap : tmp = tmp = tmp = tmp = tmp = trap : imp : trap : 5.950487 volt~, = TANK LEAK TEST PROGRAM 82.S~42 F, ht : 82.8863 F 84.5748 F 85.5058 F 86.8525 F 87.8845 F 86.9501 F 88.0195 F 87.4494 F .5950 inches ht = ht : hr': ht : ht : ht : ht : h.t : 42 00 S1 00 80 00 69 09 87 8~ 96 Disc Number NDE Environmental Corp. .Copyright I~86-1990 All rights reserved. Tank Owner .................... : PAC-BELL SSAOO4-BAKERSFIELD Tank. Number ................... = 40K O!ESEL ~33t Measurement S .~ Date of Measurement = 09/28/'1990 Time of measurement ........... = 1£:58:S~ Tank. Temperature .............. = Tank. Pressure ................. = Basic Tank Volume ,*****~'****** : Temperature Correction ******** : PRessure Correction *********~* = Corrected ~olume ************** : Stratified Corrected Volume *** = Total Fluid Lev'el ............. = ¢tuid Pressure on ,Tank. Bottom = Total Temberature Ohange ...... = To(al Level Change ............ = S5.8417 degrees F. .8310 psi. 20Q8~.705 Gallons. 233.018 Gallons. .077 Gallons. 20237.880 Gallons. 20238,538 Gallons. 144.21888 inches, -.00Bi? degrees F. -.'78114 ~nches. Leak. Rate Calculation T~ma ..... : 01:02:00 Geometry Band ........... ' ...... : Rate of Temperature ~.~ng: .... Volume Change ................. = Expected Level Change ......... : Measured Level Change ********* = Primary Apparent Leak *~***~' = Primary 6pp~ran't Leak Rate '~+* = Strat Oolume Change *********** = Strat Expected Level Change *** = Strat Apparen~ Leak ******~*** : Strat ~pparent Leak. Rate ****** : R,,.g Measured Level Change ..... : ~vg'Volume Change ............. : Avg Expected Level Change ..... : ~vg Apparent Leak ............. : A~g Apparent Leak. Rate ........ : Avg Strat Uolume Change ******* : Avg Strat Expected Level Change : Avg Stret Apparent Leak ~****** = Avg Strat Apparent Leak. Rate ** : .8001 Gallons/Hour. .0005Z degrees F/Hour. .00S Gallons, O~B~ inches. - 23889 inches. 0494 6¢.[lons. 048 Gallons/Hour. - 0808 Gallons. - 00411 inches. 0438 Gallons. 042 Gallons/Hour. - 25585 inches. -.0302 Gallons. -.16049 laches. .0180 Gallons. .017 Gallons/Hour. -.0328 Gallons. -.17437 inches. .0154 Gallons. .OIS Gallons/Hour. Total Elapsed Test 'Time ....... = 01:S8:19 Processing Tank. Number 1 Bate Point Number 24 Tank Pressure Transducer Uoltage= 3.3269 volts Tmp~ 1 Tmp~ 2. Tmp~ 3 Tmp&t 4 Tmp~: B Tmp~: B Tmplt 7 Tma~ 8 Tmp~ 9 Ch~. 0 R : Ch;* S R = Ch~ 1 R = Ch~ B R = Ch~ 2 R = Ch~ ? R = Ch~ J R =. Ch*~ 8 R = Ch~t 4 R = Tank Level Readings: 4374.78 ohm 4341.20 ohm 4167.38 ohm 4078.10 ohm 3948.88 ohm 3861.70 ohm 3842't0 ohm 5893.S0 ohm tmp tmp trap tmp tmp imp tmp tmp 5.829877 voit~, = ~'2.S398 F, ht : £4.,3,3 82.88~3 F, ht = 33.9~ S4.5748 F, nt = 42.98 8B.4BBl F, ht = 51.80 8G.8481 F, ht = 68.99 87.7944 F, ht = 69.¢8 SB 9S23 ? ht = '~.98 88.0187 F, ht = B?.09 87.4481 F, ht = 96.80 .S830 inches T~NK LE~K TEST PROGRAM Oisc Number 412015 NDE Environmental Corp. Copyright 1986-1990 ~ll rights reserved. Tank Owner .................... = P~C-BELL ~SROO4-B~KERSFIELD Tank. Number ................... = 20K OIESEL ~551 Measurement ~ 24 Bate of measurement = 0g/£8,'1990 Time of measurement ........... = 13:03:S? Tank. Temperature .............. Tank. Pressure ................. Baszc Tank. Volume ~***,****-*** Temperature Correction ******** Corrected Volume ************** Stratified Corrected Volume *** Total Fluid Level ............. Fluid Pressure on ~ank Bottom Total Temperature ~hange ...... l'o~al Level Change ............ 85. 8346 degrees F. .83t7 psi. 20004.705 ,Sa[Ions. 232.gS4 6allons. .877 Gallons. 20237.736 Gallons. ,~0,, 3B. 487 Gallons. 144.20680 inches. 4.4287 psi -.81227 degrees F. -.793£0 inches. Leak. Rate Calculation Time ..... = 01:01:S7 Geometry Band ................. = Rate of Temperature Change .... = Uoiume Change ................. = Expected Level Change ......... = Measured Level Change ********* = Primary 6pparent Leak ********* : Primary apparent Leal,:. Rate **** = Strat Volume Change *********** : Strat Expected Level Change *** = Strat ~pparent Leak. ****'**~*** = Strat ~pparent Leak. Rate ****** =' Avg Measured Level Change ..... = Avg Volume Change ............. = ~vg Expected Level. Change ..... = ~vg Rpparent Leak ............. = ~vg ~pparent Leak Rate ........ = ~vg Strat Vblume Change ******* : ~vg Strat Expected Level Change = ~vg Strat ~pparent Leak. ******* : 6vg Strat Apparent Leak. Rate ** = -.0019 Gallons/Hour. -.01051 degcees F/Hour. -.099 Gallons. -.52374 inches. -.25041 inches. -.0S14 Gallons. - 050 Gallons/Hour. - 0902 Gallons. - 47g~1 inches. - 0431 Ga]lonG. - 042 Gallons/Hour-. - 24812 inches. - 0494 Ga/Ions. - 2625S inches. - 0027 Gallons. - 00~ Gallons/Hour. - 04.?3 Gallons. - 2SllS inches. - 0006 Gallons. -.001 Gallons/Hour". Total Elap:~ed =le:t- 'r Lee = 02:05''''* Processing Tank. Number 1 Data Point Number 26 Tank Pressure Transducer Voltage = ~.J=¢8 volts Tmp~ 1 Tmp~ £ Tmp~ ~ Tmp~ 4 Tmp~ ~ Tmp~ B Tmp~ ? Tmp~ 8 Tmp~ 9 Ch~ 0 R = Ch~ S R = Ch~ 1 R = Ch~ B R = Ch~ 2 R = Ch~ 7 R = Ch~ 5' R = Ch~ 8 R = Ch~ ¢ R = Tank: Level Readings: 4574..80 ohm 4558.98 ohm 4187.78 ohm 4877.50 ohm 5848.88 ohm 5939.38 ohm 3840.10 ohm ~893.90 ohm s.sSg277 volt , tmp = tmp = imp = imp = imp = imp = imp = imp = tmp = 82.882S Fht = 84.5708 F ht = 85.4925 F ht = 8B.8481 F ht = 8?.?9?? F ht = 86.9901 F ht = .0~ F ht = 87.44~1 F, ht = .SSS9 inches 24 0~ 42 80 SI 80 B9 00' 8? 0~ TANK LEAK TEST PROGRAM Disc Humber I12015 NOE Environmental Corp. Copyright 1986-1990 &l'l rights reserved. Tank Owner .................... = PhC-BELL ~SA884-BAKERSFIELB Tank. Number ................... = 28K OtESEL ~331 Measurement ~ 29 Bate of measurement = 09/28/1998 Time of measurement ........... = 13:09:08 Tank. Temperature .............. : Tank Pressure ................. = Basic Tank Volume ************* : Temperature Correction ******** = Pressure Correction *********** = Coppeotad Volume ************** = Stratified Corrected Volume **'* : Total Fluid Level ............. = Fluid Pressure on Tank Bottom Total Tem~eGature Change .: .... : Total Level Change ............ 85.8598 degrees F. .8312 psi. 20004.705 Gallons. £33.~01 Gallons. .077 Gallons. 20~ . ~37.783 Gallons. ~8~Jb.S23 Gallons. · ,9~4 inches. 144 1~ ~ 4.4273 psi -.08789 degrees F. -.82028 inches. Leak Rate CaLculation T~me ..... : 01:01:4'7 Geometry Band ................. Rate of Temperature Change .... Uolume Change ................. Expected Level Change ......... Measured Level Change ********* Primary Apparent Leak ********* Primary Apparent Leal.: Rate **** Strat Uolume Change *********** Strat Expected Level Change *** Strat Apparent Leal,: ****~*~.**'* Strat Apparent Leak Rate ****** 6vg Measured Level Change ..... Bvg Volume Change, . ............ Avg Expected Level Change ..... Avg Apparent Leak .............. hvg Apparent Leak Rate ........ Avg Strat Volume Change ******* 6vg Strat Expected Level Change hvg Strat Apparent Leak, ******* 6vg Strat Apparent Leak Rate ** -.0005 Gallon~,'Hcur'. -.00270 degrees F."Hour. -.OZB Gallons. -.137~2 inches. -.~8941 inches. .8248 Gallons. .02~ Gallons/Hour. -.0210 Gallon~. -.lll?l inches. .829? Gallons. .829 Gallons/Hour. -.2S8B~ inches. -,041S Gallons. -.22843 inohas. .086? Gallons. .80B Gallons/Hoot, -.8589 Gallons. --.28BB4 inches. ,0883 Gallons. .888 Gallons/Hour, Total Elapsed Tesf Time ....... = ~2':08:2B Processing Tank. Number 1 Oats Point Number 28 Tank Pressure Transducer Voltage = 3.~ Tmp$ I Tmp~ 2 Tmp~ ~ Tm~ 8 Tmp~ 7 Tmp~ g Ch~t 0 R = Ch~ S R = Ch~ 1 R = Ch~ 8 R = Ch~ 2 R = Ch~ 7 R = Ch~ 3 R = Ch~ 8 R = Ch~ ¢ R = Tank Level Readings: 4575.20 ohm, tmp= 82.534£ F ~mp = 82.8709 F -imp = 84.58'38 F tmp 85.50,~ F tmp= 88.8481 F tmp= 87.8065 F tmp= 88.954A F tmp= . 88.0098 F tmp= 8?.4494 F .~4~977 volts, = ..S~4J inches 4340.!0 ohm 4187.80 ohm 4076.00 ohm ~848.80 ohm 3880.80 ohm 5958.90 ohm 3842.20 ohm 3893.20 ohm ht = ~4.~ ht = ht = ~.9~ ht = S1.00 hr. = 80.00 ht = ht = ht = 87.90 ht = 88.~0 T~NK LEGK TEST PROGRRM O£SO Number ~1~0',3 NDE Environmental Corp. Copyright 188G-1980 ~ll rights reserved· Tank. Owner .................... = P~C-BELL ~SR004-BAKERSFIELD Tank. Number ................... = 20K DIESEL ~3~1 Measurement ~ 28 Date of Measurement = 08/28/1'~80 Time of measurement ........... = Tank Temperature .............. = Tank Pressure ................. = Basic Tani. Uolume ~****~****** = Temperature Correction *,~****** = ~ressure Correc~ion *********** = Corrected Volume ~*+*~***,****~ : Stratified Corrected Uolume *** = Total Fluid Level ............. = Fluid Pressure on'Tar, k Eottom : ,,~i Te&perature %;hangi ...... = Total Level Change ............ = 85.8588 degrees F. .8307 psi. 20~.705 "-'~ LJ~l ~on5 , ~J~.8~Z Gallons. .077 Gallons. J,.~,~ Gallons. 20258.518 iSalions. 14a.l~Bll ~nches. ~.~289 -.00785 degrees F. -.85189 knches. Leak Rate Calculation Time ..... = 01:~1:55 Geometry Band ................. : Rate of Temperature Change .... = Uolume Change ................. = Expected Level Change ......... = Measured Level Change **+****** = Primary' ~pparent Leak '****~**"* = Primary 6pparen~ L_mal:: Rate ~+ =' ~tcat Uolurq~ ~harige *~ · ~''~ ~**** = Sir-at Expected Level Change *** = Strat Apparent Leal;:. *****,~*~*** = Strat 6pparent Leak Rate ****** = ~vg Measured Level Change ..:.. = ~vg Oolume Change ............. = Avg Expected Level Change ..... = hvg ~pparent' Leak ............. = hvg 6pparent Leak Rate ........ = 6vg Strat Uolume 'Change ******* = ~vg Strat Expected Level Change = 6vg S'trat 6pparent Leal< ******* = 6vg Strat 6pparent Leal,: Rate ** = -.0002 Gallons/Hour. -.00087 degrees F/Hour. -.009 Gallons. -.04837 inches. -.27478 ~nches. · 0450 Gal Ions. .042 Ga [ lens/Hour-. -.01.42 Gallons. -.07583 ~nches. 0375 Gallons. 036 6allon~/Hour. - 25848 inche~. - 0358 Gallons. - 18835 ~nches. 0128 Gallons. 012 Gallons/Hour. - 8344 Gallons· - 1828g inches. 0138 Gallons. 013 Gallons/Hour. Total Elapsed Test lime ....... = 02:13:35 Processing Tank Number I Data Point Number ~¢ Tank. Pressure Transducer Voltage TM 3.3193 'volts Tmp~ 1 Tmp~ 2 Tmp~ 3 Tmp~ 4 Tmp~ 5 Tmp~ 8 Tmp~ 7 Tmp.~ 8 Tmp~ 9 Ch~ 0, R = Ch~ S: R = Ch~ 1 R = Ch~ 8 R = Ch~ 2 R = Ch~ 7 R =. Ch~ 5 R = Ch~ 8 R = Ch~ 4 R = · Tank Level Readings: 4374 80 ohm, t'mp = 4342 80 ohm, tmp= 4187 S0 ohm, tmp= 4078 28 ohm, tmp= 3948 90 ohm, tmp= 3889 £0 ohm, tmp= 5959.48 ohm, tmp= 3841.50 ohm, tmp= 3893.10 ohm, tmp: S.~oS~S¢ volts, : 8~.838~ F, ht = 82.8449 F, ht = 85.4881F S6.8470 F 87.8219 F 88.8196 F 87.4SOS F .8238 inches ht = ht : ht : ht ht = ht : TANK LEAK TEST PROGRAM Disc Number NDE Environmental Corp. Copyright t988-1990 6ll rights reserved. Tank Owner .................... : PAC-BELL ~S~004-B~KERSFIELB Tank. Number ................... = 20K OIESEL ~531 Measurement = 27 Date of measurement = 08/28/1990 Time of measurement ........... = ]3:19:19 'Tank, Temperature .............. : Tank. Pressure ................. = Basic Tank Volume ************* = Temperature Correction ******** = Pressure Correction *********** = Corrected Volume *~************ = Stratified Corrected Volume ~** = Total Fluid,Level ............. : Fluid Pressure on' lank Bottom = Total TeAperature~Ohange ; ..... = To~al Level Change ............ = 85.8365 degrees F. .8298 psi. 2000a.705 Gallons. ~.971 Gallons. .077 Gallons. ~0~.753 Gallons. 28£38.808 Gallons. 144.14734 inches. 4.4288 psi -.~1038 degrees. F. -.85286 inches. Leak. Rate Calculation Time ..... = 01:02:~2 Geometry Band ................. Rate of Temperature Change .... VoLume Change ................. Expected Le'¢el Change ......... Measured Level Change ********* Przmary Apparent Leak. ********* PrimDry Apparent Leak Rate ~*** Strat Volume Change *********** S'trat Expected Level Change *** Strat Apparent Leak *****'~*.**** Strat Apparent Leak Rate ****** Avg Measured Level change ..... Avg Volume Change ............. Avg Expected Level Change ..... 6vg Apparent Leak ............. Avg Apparent Leak Rate ........ 6vg Strat Volume'Change '******* Avg Strat E;,pected Level Change ~vg Str-at 6pparent Lea[: ~'****** 6vg Strat Apparent Leak Rate ** -.0005 Gallons/Hour. -.00255 degrees F'Hour-. OZG Gallon~. - 15578 inches. - 25~95 inches. ~ Gallons. 022 ~allons/Hour. - 0186 Gallons. - 08817 inches. 0312 Gallons. .030 Gallons/Hour. -.28709 inches. -.0308 Gallons. -.1G3S7 inches. .0176 Gallons. .017 Gallons/Hour. -.8288 Gallons. -.IS17~ inches. .0198 iSa/Ions. .~19 Gallons/Hour. Total Elap:5ed Test T~me ....... = 02:18:44 Processing Tank. Number 1 Oats Point Number 28 Tank. Pressure Transducer 'Voltage = 3.3171 volts Tmp~ 1 Tmp~ 2 Tmp~ 3 Tmp~ 4 Tmp~ S Tmp~ B Tmp~ ? Tmp~ 8 Tmp~ 9 Ch~ 0 R = ChCb 5 R = Ch~ 1 R = Ch~ t~ R = Ch~ 2 R = Ch~t 7 R = Ch~ 3 R = Ch~ 8 R = Ch~ 4 R = Tank Level Readings: 4578.00 ohm 4544.00 ohm 4167.48 ohm 4077.70 ohm 3948.98 ohm ;859.90 ohm 5939.80 ohm 3840.60 ohm 389;.;0 ohm tmp = tmp = tmp = tmp = tmp = tmp'= 5.160490 volts, = 82.5381 F, ht = 82,833Z F ht = 84,8758 F ht = 85.4902 F ht = 86.84?0 F ht = 87.8142 F ht = 88.944'7 F 88.0273 F 87.4485 F S160 24.00 53.00 4~.00 51,00 60.00 89.00 ht = .78.00 ht = 87.80 ht = SG.00 TANK LEAK TEST PROGRAM Ozsc Number 41£~15 NDE Environmental Corp. Copyright 1986-1990 ~ll rights reserved. Tank. Owner .................... = PAC-BELL ~SAOO4-BAKERSFIELD Tank. Number ................... ~ ' = ~Ok OIESEL ~;31 Measurement ~ ~ Dat~. of measurement : 09/~0, ,890 .... Time of measurement ........... : 13:24:29 Tank Temperature .............. Tank. Pressure ................. Temperature Correction ***~**** Pressure Correction Corrected Volume ************** S~ratif~ed Corrected Volume ~+* Total Fluid Level ............. Fluid Pressure on Tank Bottom Total Temperature Change ...... Total Level Change ............. 85.8350 degrees F. .8283 psi. 2008~..705 Gallons. 232.957 Gallons. .077 Gallons. 20237.739 Gallons. 20235.4~0 iSa[Ions. 144.13986 inches. 4.4288 psi -.0119~ degrees F. -.8601~ inches. Leak Rate Calculation Time ..... = 01:01:59 Geometry Band ................. Rate of Temper-a~ur'e Chang~ .... Volume Change ................. Expected Level Change ......... Measured Level Change'****~**** Primary ~pparent Leak ********* Primary ~pparent Leak. Rata **** Strat Volume Change *********** Strat Expected Level Change *** 8trat ~pparent Leak ******~*.*** Strat ~pparent Leak, Rate ****** 6vg Measured Level Change ..... ~vg Volume Chan~e ............. ~vg Expected Level Change ..... ~vg ~pparent Leak .............. ~vg ~pparent Leak Rate ..... ;.. 6vg S(ra~ Uolume Change ******* 6vg S~ra( Expected Level Change ~vg Strat ~pparent Leak ******* Rvg Strat Rpparent Leak Rate ** -.0006 Ga[ tons/Ho:ur-. - 00328 degr'ees F,'Idou~ . 031 Ga[ions. 18471 inches. 23954 inches. 01~1 Gallons. 014 Galloms/Hour. ~24~ Gallons. 12740 ~nches. 021! Gallons. 020 Gallons/Hour. 25752 inches. 0379 Gallons. 20184 inches. 0105 Gallons. 010 Gallons/Hour. 0~;2 Gallons. 17844 inches. 0153 Gallons. 015 Gallons/Hour. Total Elapsed Test Time ....... = 02:~J:SB Processing Tank. Number 1 Data Point Number 29 Tank Pressure Transducer Voltage = 3.3155 vol{s Tmp~ I Ch¢ 0 Tmp~ 2 'Ch~ B Tmp~ 3 Ch~ 1 Tmp~ 4 Ch~ 6 Tmp~ 5 Ch~ 2 Tmp~ 6 Ch~ ? Tmp~ ? Ch~ 3 Tmp~ 8 Ch~ 8 Tmp~ 9 Ch~ 4 Tank'Levet Reac R = 4374.80 ohm R = 4344.00 ohm R = 4187.60 ohm R = 4077.70 ohm 'R = 3948.88 ohm R = 3861.50 ohm R = 3939.60 ohm R = 3842.50 ohm R = 3893.~0 ohm ings: t~p imp tmp tmp = tmp = tmp = tmp = tmp = tmp = 4.9969¢3 volts, = 8Z.5380 F 82.8333 F S4.5718 F 85.4982 F 36.8481 F 8?.?966 F 86.9469 F 88.8863 F 9?.4494 F .4997 inches ht = ht = ht = ht = ht = ht = ht = ht = ht = Si.00 89.00 7.8.~8 96.00 T~NK LE~K TEST PROGRRM' Oisc Number 41£~13 NDE Environmental Corp. Copyright 1986-1990 ~ll right8 reserved. Tank Owner ..................... = P8C-BELL ~S8004-BAKERSFIELD Tank Number ................... = 20K DIESEL ~331 Measureme.nt ~ Date of measurement = 0912811990 T.ime o¢ measurement ........... = 13:29:38 Tank. Temperature .............. : Tank. Pressure .................. = Basic Tank Uoiume ~*******~**** = Temperature Correction ***~**** = Pressure Correctio~ *********** = Corrected ~olume ************** = Stratified Corrected Uolume *** : Total Fluid Level ............. = Fluid Pressure on Tank Bottom = Total $emp~ra~ure CRange ...... : Total Level Change ............ = 85 8289 077 20~J, 705 20236 144 1,.2_l inches. 4.4',.'8 ~ psi -.8~573 degrees F. -.37648 ~nches. Leak. Rate Calculation Time ..... : 01:01:55 Geometry Band ... .............. Rate of Temperature Change .... Uoluma Change ................. Expected Level Change ......... Measured Level Change ********* Primary ~pparent Leak ********* Primary ~pparent Leak. Rate **** Strat Volume Change *********** Strat Expected Level Change *** Strat ~pparent Leak *******t~.** Strat ~pparent Leak Rate ****** 6vg Measured Level Change ..... Rvg L)olume ChiCago ............. ~vg E;~pected Level Change ..... ~vg ~ppanent Leak ............. ~vg Rpparent Leak Rite ........ ~vg 6trat Uoiume C~ange ******* 6vg Strat Expected Loyal Change 6vg Strat ~pparent Leak ~*~**** ~vg Strat ~pparent Leak. Rate ** degrees F. psi. Gallons. Sailors. 5altons. Gallons. Gallons. -.0013 Balion~/Hour. -.0~729 degrees -.988 5at!ors. -.38383 inches. -.219&1 inches. -.0271 Gallons. -.028 Gallons/Hour. -.0572 Gallons. -.30417 inches. -.O1GO Gallons. · -.015 Gallons/Hour. ~m142 - 16962 inches. 0154 Gallons. OIB Gallons/Houi~. - 0268 Gallons. - 141'~4~ inches. 020? Gallons. 020 Gallons,'Hou~'-. Total Elapsed Test Time ....... : 02:'29:01 Processing Tank. Number ] Data Point Number 30 Tank. Pressure Transducer Voltage = j.311~~ volts , Tmp~ 1, Ch~ Tmp~ 2, Ch~ Tmp~ 3 Ch~ Tmp~ 4 Ch~ Tmp~ 5 Ch:~ Tmp~ 8 Ch~ Tmp~ ? Ch~ ~Tmp~ 8 Ch~ Tmp~ 9 Ch: 0 R = S R = 1 R = 8 R = 2 R = 7 R = ~ R = 8 R = 4 R = Tank, Level Readings: 4374.90 ohm 4340.80 ohm 4167.80 ohm 4077.50 ohm 3880.20 ohm tap tmp = tmp = ~m~ = ~84~.20 ohm, tmp = 3893.40 ohm, tmp= 4.9903?0 volts, = 82.5571F 82.8842 F 84.5898 F 85.4923 F 85.8459 F 87.8108 F 8G.94G~ F 88.0086 F ,4~90 £nches ht = ht = 42.00 ht = SI.O0 ht = 80.~0 ht = ht = 78.0~ ht = 87.0~ ht = TANK LE~K TEST PROGRAM Disc Number 41'2015 NDE Environmental Corp. Copyright 1'988-1980 811 rights reserved. Tank Owner .................... = PAC-BELL ~SAOO4-BAKERS. FiELD Tank Number .' .................. = 20K OIESEL ~331 Measurement ~ 30 Date of measurement = 09/28/1980 Time of measurement ........... = 13:3~:¢g Tank Temperature .............. = Tank. Pressure ................. = Basic Tank tJolume ************* Temperature Correction ~******* = Pre=-ure~,~ Correction *********** = Oorreoted Volume ************** = $~ratif~ed Corrected Uo~ume ~** = Total Fluid Level ............. F~uid Pressure on~ Tank 8ottom = Total TeNperature~Change ...... = [otal Level Change ............ 85.83~0 degrees F. .8278 psi. 20~04,705 Gallons. 252.988 Gallons. .~77 Ga,Lions. 20237.748 Gallons. 20238.497 Gallons. 1~4.12285 ~nches. ~.4281 psi ~.01095 degrees F. -.87715 znches. Leak, Rate Calculation Time..... = 01:01:SS Geometry Band ................. Rate of Temperature Change .... Uolume Change ............ - ..... Expected Level Change .... · ..... Measured Level Change ********* Primary Apparent Leak ********* Primary Apparent Leak. Rate **** Strat Volume Change *********** Strat Expected La'vel Change *** Strat Apparent Leak *****~**** ~t, a+, Apparent Leak Rate ****** Av'g Measured Level Change ..... 6vg Volume Change .......... ~.. Avg Expected Level Change ..... Erg Apparent Leak .............. Avg Apparent Leak Rate ........ (~vg Strat Volume'Change ~****** A'vg Strat Expected Level Change 6vg Strat Apparent Leak ******* 8vg Strat 8pparent Leak Rate ** -.0007 Gallons/Hour. -.00388 degrees F/Hour. - 037 Gallons, - 18~17 inches. - £1833 inches. 0042 Gallons. 004 Gallons/Hour. - 0329 Gallons. - 17&~1 inches. 0078 Gallons. .0~8 ~aZlon~/Hour. -.24080 inches. -.03&l Gallons. -.1BOB3 inches. .0113 Gallon~. .011 Gal'ions/Hour. -.0290 Gallons. -.1540~ inches. ,01G~ Gallons. .01~ Gallons/Hour. Total Elapsed Tes't.T.Lme ....... = 02:34-:14. Processing Tank. Number I Oats Point Number 31 Tank Pressure Transducer Voltage = 3.30£7 volts TmpS 1 Tmp~ 2 Tmp~ 3 Tmp~ 4 TmpS S Tmp~ 6 TmpS 7 Ch~ 0 R = Ch~ S R = OhS 1 R = ChS 8 R = Ch~ 2 R = Ch~ 7 R = Ch~ 3 R = OhS B R = Ch~ 4 R = Tank'Level Readings: 4374.70 ohm 4339.90 ohm 4167.90 ohm 4078.10 ohm 3949.20 ohm 3859.B0 ohm 3939.40 ohm 3841.10 ohm 3893.40 ohm tMp imp = tmp : imp = imp = imp = imp = imp = imp = volts, : 82.8728 F 84.5888 F 86.8438 F 87.8~86 F ht : ht : ht : ht = ht : ht : 96.S4$0 F, ht = 88.0218 F, ht = 87.4472 F, ht = · 4988 inches 24 ¢0 42 0~ 51 TANK LEAK TEST PROGRAM Disc Number 412~13 NDE Environmental Corp. Copyright 1~86-1~80 ~ll rights reserved. Tank Owner .................... = PAC-BELL ~SAOO4-BAKERSFIELO Tank. Number ................... = 20k DIESEL ~3~1 Measurement ~ Si Oats of measurement : 08i28/1990 T~me of measurement ....... .... : 13:~9:54 Tank:. Temperature .............. = Tank Pressure ................. = TeMperature Correctlolq **+****% = Strati¢ied Correctad tJolume *~* = Total Fluid Level ............. = F~u~d Pressure on Lank 8o~tom = Total Temp~erature C~ange ...... = Total Level Change ............ = S5.8386 degrees F. .8257 psi. 208~4.705 Gallons. ~.989 Gallons. .~78 Gallons. 20237.77l Gallons. 20238.518 Gallons. ]44.]~81 inches. -.00835 degrees F. -.87719 inches. Leak. Rate Calculation Time ..... = 01:01:48 Geometry Band ................. = Rate of Temperature Change .... = Volume Change ................. : Expected Level Change ......... = Measured Level Change ~'~*''"" = Primary 5pparent Leak. Rate ***'~ = Strat Volume Change *********** = Strat Expected Leve~ Change *** = Strat ~pparent Leak. *******~** = Strat ~pparent Leak· Rate ****** = Rvg MeaBured Lave1 Change ..... = 6vg Uoiume Change ............. = 'Gvg Expected Level Change ..... = 6vg Apparent ~eak .......... ;.. = hvg. hpparent Leak. Rate ........ = hvg Strat Uolume Change ******* = 6vg Strat Expected Level Change = 6vg Strat 6pparent Leak *~***','* = 6vg Strat ~pparent Leak Rata *~ = -.0008 Gallons/Hour. -.004]3 degrees r,Ho~r. -.033 Gallons. - °0683 inches · -.17~38 Inches. -.0052 -.005 Gallons/Ho,aP. -.0315 Gallons. -.18747 inches. 00~ · ~= Gal. lons. .~02 Gallons/Hour. - ~173 inch'es -.0401 Gallons. - ' 30£ . .~1 inches .001~ Gallons. .002 Gallons/Hour. -.0~£~ Gallons. · ~4~ inches. .00~3 Gallons. .009 G~llons/Hour. 'Total Elapsed 'Feat 'Time ....... = 02:39:1'3 Process. lng Tank. Number 1 Data Point Number J4 Tank Pressure Transducer Voltage = 5.2865 volts Tmp~ 1 Tmp~~ ~ Tmp~ 3 Tmp~ 4 Tmp~ S Tmp~ 6 Tmp~ ? Tmp~ 8 Tmp~ S Ch~ 0 R = Ch~ S R = Ch~: 1 R = Ch~: B R = Ch:iS 2 R = Ch~ ? R = Ch~ 5 R = Ch~ 8 R = Ch~ 4 R = Tank; Level Readings: 4374.70 ohm 4358.80 ohm 4167.30 ohm ¢077.S8 ohm 3849,20 ohm 38B1.40 ohm ~939.S0 ohm 3940.20 ohm 5895.S0 ohm tmp = tmp imp = {mp = tmp = tmp = tmp = tmp = tmp = 4.861185 'volts, = 8£ S590 F 82 8854 F 04 S688 F 85 4882 F 86 8458 F 87 7977 F 86. 9480 F 88..8317 F ht = 24.~0 ht = ==.~0 ht = 4£.00 ht = Si.~¢ ht = 60.~ ht = ht = ht = 87.4461 F, ht = .4861 inches TANK LEAK'TEST PROGRAM Disc Number !lZ¢15 NOE Environmental Corp. Copyright 1986-1888 All rights r~served. Tank Owner .................... = PAC-BELL ~SAOO4-BAKERSFiELD Tank Number .... ............... = 20K OIESEL ~5~1 Measurement ~ ~ Date of measurement = 09,'£8/1~0 Time of measurement ........... = 13:44:58 Tank. Temperature .............. = Tank Pressure ................. = Basic Tank. iJolume ***~**~****** = Temperature Correction ******** : Pressure Correction *********** : Corrected (/olMme ************** = Stratified Corrected Uoiume *** = Total Fluid Level ............. = Fluid Pressure on 'Tank. Bottom = Total Temberature Ohange ...... = Total Level Change ............ = 85.8585 degrees F. .821E psi. 20~0~.705 Gallons. 232.989 Gallons. .079 Gallons. 20237.770 Gallons. ~O~b.SI5 Gallons. 144.10995 inches. 4.4257 psi -.¢0840 degrees F. -.89007 inches. Leak Rate Calculation Time ..... = Geometry Band ................. Rate of Temperature ChaRge .... Volume Change ................. Expected Level Change ......... Measur.ed Level Change ********* Primary ~pparent Leak. ********* Primary Apparent Leak Rate**** Strat Volume Change *********** Strat Expected Level Change ~** Strat apparent Leak *******~*** Strat Apparent Leak Rate ****** Avg Measured Level Change ..... Avg Volume Change ............. Avg Expected Level Change ..... Avg Apparent Leal:: .............. Avg Apparent Leak. Rate ........ Avg Strat Volume Change ~****** Avg Strat Expected Level Change Avg Strat Apparent Leak. ******* Avg Strat Apparent Leal Rate *.* ,0004 Gallons/Hour. ,00245 degrees F/Hour. 0~ Gallons. .1154~ inches. -.18101 inches. .0558 Gallons. .054 Gallons/Hour. .0107 Gallons. .0S70~ inches. .0~48 Gallons. .044 Gallons/Hour. -.2071~ inches. -.050G Gallons. -.1~278 inches. .0083 Gallons. .008 Gallons/Hour. -.0270 Gallons. -.14338 inches. .0120 Gallons. .012 Gallons/Hour. Total Elapsed 'rest 'f'Lme ....... = 02:44:21 Processing Tank. Number 1 Data Point Number 33 Tank Pressure Transducer Voltage : 3.~ =~ ~9~ voit5 Tmp; 1 Chg Tmp; £ Ch~ Tmp~ 3 Ch~ Tmp~ 4 Ch~ Tmp~ S Ch~ Tmp~ G Tmp~ 7 Ch~ Tmp; 8., Ch~ Tmp~ g, Ch~ 0 R = S R = 1 R = B R = £ R = 7 R = 3 R = 8 R = 4 R = Tank'Level Readings: 4374.78 ohm 4343.00 ohm 4188.00 ohm 4077.10 ohm 3949 ~ .~0 ohm 3889.80 ohm 5841.40 ohm =°SS 40 ohm 4.674473 volt tmp = imp = imp = imp imp imp = imp = imp = imp o? S390 F ht = ~.8430 F h! = S4.8678 F ht = 8'S.4964 F ht = S6.8439 F ht 87.8183 F ht = 88.$488 F, ht = 88.8185 F, h±. = S7.~0 .... 4 F h t . , .4674 inches TGNK LEAK 'TEST PROGRGM , '- -- , NDE Environmental Corp. Copyright 1~86-1990 ~ll rights reserved. Tank Owner .................... = P~C-BELL ~S~004-B~KERSFiELB Tank Number ................... = 20K OIESEL ~331 Measurement ~ ~ Date of measuremen~ = 0~tZ8/'1~0 Time of measurement ........... = 13:50:1"~ Tank Temperabur~ .............. = Tank Pressure ................. = Basle Tank Volume *'*********** = 20004 Temperature,Correction *****~*~ = 232 Pressur~ Correct~cn *********** = Corrected Volume ************** = 204~, Strati¢ied Corrected Volume *** = ~0~6~= Total Fluid Level ............. = l~ Fluid Pressure on Tank. Bottom = Total Temderature C~ange ...... = Total Level Change ... .......... = 88.8352 8233 708 959 076 740 493 091~6 inches. 4.4251 -.01172 degrees F. -.80874 inches. Leak Ra±e Calculation Time ..... = ~1:01:44 Geometry Band ................. Rate of Temperature Change .... Vo~ume Change ................. Expected Level Change ......... Measured Level Change ********* Primary ~pparen~ Leak ********* Primary ~pparent Leak Rate **** Strat Volume Change **~******** Strat Expected Level Change *** Strat ~pparent Leak *******m~** Strat ~pparent Leak. Rate .****** ~vg Measured Level Change ..... ~vg Volume Change ............. Rvg Expected Level Change ..... Avg ~pparent Leak .............. ~vg Rpparent Leak Rate ........ ~¢g Strat Volume Change ******* ~vg Strat Expected Level Change ~vg Strat Rpparent Leak ******* ~vg Strat &pparent Leak. Rate ** degrees F. psi. Gallons, Gallons. Gallons. Gallons. Gallons. · -'.0011 G,s[~ons/Ho,.~r. -.00614 degrees F. Hour. -.dSS Gallons. -.30755 inches. -.1728£ inches. -.0284 Gallons. '-.028 Gallons/Hour~ -.0482 Gallons. -.24548 ~nches. -.0137 Gallons. -.013 Gallons/Hour. -.lg375 inches. -.0380 Gallons. -.18138 ~nches. .0008 Gallons. 0.000 Gallons/Hour. -.0514 Gallons. -.18700 inches. .0050 Gallons. .008 Ga!l~ns/Hour. To!al Elapsed Test Time ....... = 02:49:38 Processing Tank Number ~ Oats Point Number Tank Pressure Transducer Voltage : 3.3069 vol~s Tmp~ 1 Tmp~ £ Tmp~ 3 Tmp~ 4 Tmp~ B ~mp~ 6 Tmp~ 7 Tmp~ 8 Tmp~ 9 Ch~ 0, R = Ch~ S, R = Ch~ · 1 R : Ch~ 6 ' R = Ch~ Z, R'= Ch~ 7, R = Ch~ 3, R = Ch~ 8, R = Ch~ 4, R = Tank'Level Readings: 4374.70 ohm, tmp= 4343.70 ohm, tmp= 4188.10 ohm, fpp = 40?7.50 ohm, tmp= 3949.50 ohm, tmp= 3860.20 ohm, tmp= 3939.90 ohm, tmp= 3841.70 ohm, tmp= 3893.40 ohm, tmp= 4.673933 volts, = 82 S390 F, nt = 82 8362 F 84 SAG? F 85 4923 F 88 8405 F 87 8189 F 86 9437 F 88.0151F 87.44?2 F .4874 inches TANK LEAK TEST PROGRAM Disc Number NDE Environmental Corp. Copyr'ight 1986-t890 All rights reserved. Tank Owner .................... : PAC-BELL ~SAOO4-BAKERSFIELD Tank Number ................... = 20k DIESEL Measurement ~ 34. Date of measurement : 0912811990 Time o~ measurement ........... = Tank. Temperature .............. : Tank Pressure ................. = Basic Tank Volume ************* = Temperature Correction ******** = Pressure Correction *********** = Corrected Volume ************** = Stratified Corrected Volume *** : Total Fluid Level ............. : Fluid Pressure on Tank Gattom = Total Tempera±ute Ch%nge ....... = Total Level Change ............ : 85.8324 degrees F, .8267 psi. 20004.705 Gallons. 232.93~ Gallons.. .077 Gallons. 20237.716 Gallons. 20236,473 Gallons. 144.09121 inches. 4.4251 psi -.01450 degrees F. -.90879 inches. Leak. Rate Calculation Time ..... : 01:01:37 Geometry Band ................. Rate of Temperature Change .... goiume Change ................. Expected Level Change ......... Measured Level Change ********* Primary Apparent Leak ********* Primary Apparent Leak. Rate **** Strat Volume Change *********** Strat Expected Level Change *** Strat Apparent Leak ********~* Strat Apparent Leak Rate ****** Avg Measured Level Change ..... Avg Volume Change ............. Avg Expected Level Change ..... Avg Apparent Leak .............. Avg Apparent Leak Rate ........ Avg Strat Volume Change ******* Avg Strat Expected Level Change Avg Strat Apparent Leak ******* Avg Strat Apparent Leak Rate ** -.0014 Gallons/Hour. -.00771 degrees F/Hour. -.072 Gallons. -.38249 inches. - 1488'3 inches. - 0444 Gallons. - 043 Gallons/Hour. - 0572 Gallons. - 30381 inches. - 0295 Gallons. - 029 Gallons/Hour. - 17924 inches. - 0367 Gallons~ - 19512 inches. -.0030 Gallons. -.003 Gallon's/Hour. -.0~14 Gallons. -.]6~92 inches. .0023' GalLons. .002 Gallons/Hour. Total Elapsed Test Time ....... = 02:54:42 Processing Tank. Number i Oats Point Number. 36 Tank Pressure Transducer. Voltage = 3.308 volts Tmp~ 1 Tmp~ 2 Tmp~ 3 Tmp~ 4 Tmp~ 5 Tmp~ B Tmp~ 7 Tmp~ 8 Tmp~ g Ch~ 0 R. = Ch~ S R = Ch~ 1 R = Ch~: 8 R = Ch~ 2 R' = Ch~ 7 R = Ch~ 3 R = Ch~ 8 R = Ch~ 4 R = Tank Level Readings: 4374,70 ohm 4S41.10 ohm 41G8,00 ohm 4080,20 ohm 394g,30 ohm 3880,S0 ohm 3939.70 ohm 3840.30 ohm 5BS3,80 ohm 4 G18 · l~J It tmp = tmp = tmp = tmp = 'tmp = tmp = imp = tmp = tmp 82 S3S0 F, ht = 82 84 8S 87 86 88.0308 F 87.44S0 F .4GIG inches 8813 F, ht = SB78 F, ht = 4844 F, ht = 8427 F, ht = 8Q76 F, ht = 94S8 F, ht = , ht = , ht = TANK LE~K TEST PROGR&M Oisc Number ~12013 NDE Environmental Corp, Copyright 1986-1990 ~ll rights reserved, Tank Owner .................... = P~C-BELL ~S5004-BGKERSFIELO Tank. Number ..... · .............. = 20K OIESEL ~331 Measurement ~ 3S Oate of measurement = 09/28t1990 Time of measurement ........... = 14:00:3B Tank. Temperature .............. = Tank. Pressure ................. =. Basic Tank.,Volume ************* = Temperature Correction ******** = Pressure Correction *********** = Correct'ed Volume ************** = Stratified Corrected Volume *** : Total Fluid Level ............. = Fluid Pressure on'Tank Bottom : Total TeGperature ~hange : ..... = Total Level Change ............ = 85,8338 degrees F. ,8£70 psi. 20004,70S Gallons, 232.'548 Gallons. .877 Gallons. 20237.728 Gallons. ~0,3B.478 Gallons· 144.08S43 inches. 4.424~ psi -,01312 degrees F, -.g14S7 inches. Leak. Rate Calculation Time ..... = 01:01:42 Geometry Band ................. = Rate of Temperature Change .... = Volume Change ................. = Expected Level Change ......... = Measured Level Change ********* = Primary 5pparent Leak ********* = Primary ~pparent Leak Rate **** = Strat Volume Change *********** = Strat Expected Level Change *** = Strat ~pparent Leak *****~**** = Strat ~pparent Leak Rate ***~** : ~vg Measured Level Change ..... : ~vg Volume Change ............. = ~vg Expected Level Change ..... : ~vg ~pparent Le~k ............... : ~vg ~pparent Leak Rate ........ : ~vg Strat Volume Change ******* : ~vg Strat Expected Level Change = ~vg Strat ~pparent Leak. ******* : 6vg Strat ~pparent Leak Rate ** = -,0014 Gallons/Hour, -,00773 degrees F/Hour. -.072 Gallo'ns. -.38290 inches. -.13344 inches. -,0470 Gallons, -,046 Gallons/Hour, -,0596 Gallons, - 31664 inches. - 0345 Gallons. - 034 Gallons/Hour, - 162B~ inches. - 0438 Gallons. - 23287 inches. - 0132 Gallons. - 013 Gallons/Hour, - 0368 Gallons. - 19S27 inches. - 0081 Gallons. - 006 Gallons/Hour, T.::,fal. Elap!sed .... ,:~,. [lrqe ....... = 03:00:0I Processing Tank. Number 1 Data Point Number 36 Tank Pressure Transducer Voltage = 3.306B volts Tmp~ 1 Tmp~ 2 Tmp~ 3 Tmp~ ~ Tmp~ 5 Tmp~ 8 Tmp~ 7 Tmp~ 8 Tmp~ ~ C.h~ 0 R = Ch~t S R : Ch~ 1 R : Ch~ B R = Ch~ £ R = Ch: ? R = Ch: 5 R : Ch~ 8 R = Ch~ 4 R = Tank. Level Readings: 45?4.80 ohm 4340.80 ohm 4168.40 ohm 40?9.00 ohm 3040~40 ohm ..3861.20 ohm 3939.70 ohm 3842.50 ohm 3893.?0 ohm 4.497610 imp = imp = 'imp = tmp = imp = imp = imp imp = imp = 82.8389 F 82. '~ 8b~ F 84.8637 F 88.4?68 F 86.8416 F 87.7999 F ht = ht = ht = ht = ht = ht = SG.g488.F, ht = 88.0063 F, ht = 8?.4439 F ht = .4498 inches 33.00 42.00 BO.OO 69.00 78.08 gG.Oe TANK LEAK TEST PROGRAM Oisc Number 41£013 NDE Environmental Corp. Copyright 1986-1990 All rights reserved. Tank Owner .................... = PAC-BELL ~SAOO4-BAKERSF!ELD Tank. Number ................... = £0K OIESEL ~331 Measurement ~ 36 Date of Measurement = 09128 1990 Time of measurement ............ = 14:08:44 Tank. Temperature .............. Tank Pressure ................. B~sic Tan~ Volume. ************* Temperature Correction *******.* Pr~55ure Correction *********** Corrected ~OlOMe ************** Stratified Corrected Volume *** Total Fluid Level ............. Fluid Pressure ont Tank. Bottom Total Temperat Lrme~Change ...... Total Level Change ....... · ..... 85.8315 .82GB 20004.708 232.924 .077 20237.788 20£30.481 14&.07388 inches. 4.4246 psi -.O1SS6 degrees F. -.92642 inches. Leak Rate Calculation Time ..... = 01:01:48 Geometry Band ................. Rate of Temperature Change .... !Volume Change ................. Expected Level Change ......... Measured Level Change Primary Apparen(.Leak ********* Primary Apparent Leak. Rate **** Sinai Volume Change *********** Sinai Expected Level Change ** Strat Apparent Leak. ***~*~*.**** Strat Apparent Leak Rate *.***** Avg Measured Level Change ..... ~vg tJolume ,Change- . ............. Avg Expected Level'Change ..... Avg Apparent Leak ............. Avg Apparent Leak Rate ........ ~vg Strat Volume 'Change ~**.**** A'vg Strat Expected Level Change A',.'g Strat &pparant Leal=:. **.****~ Avg Stret &pparent Leak Rate ** degrees F. psi. Gallons. Gallons. Gallons. Gallons. Gallons. -.0008 Gallons/Hour. -.00319 degrees F/Hour. -.030 6alton,'. -.18004 inches. -.13325 inches. -.0050 Gallons. -.00S Gallons/Hour. -.0281 6allons. -.13885 inches. -.0010 Gallons. - 001 Gallons/Hour. - 1S34£ inches. - 0421' Gallons. - 22381 inches. - O1=~j~ Gallons. - 013 Gallons/Hour. - 0357 Gallons. - 1BBSO inches. · - 0068 Gallons. - 007 6ailons,.'Hour. Total Elap.se.d ~-~,~=,. 'Time ....... = ¢5:05:*89