Loading...
HomeMy WebLinkAboutABOVEGROUND TANK FILE 1 'Ci~ of Bakersfield ..~ "~ C~$TO~ R£CEIFf ~ '_Op~.r: ~D~VIS Type,: OC Dra~er:l .-... llhte: 9/17/$1,~1 · ~eceipt ~o: 311~7 Tender detail ~t~{E~ 4515 $146.$e Tot, el tendered $146.e$ Total paynent $146.ee ?raasdete: 9117181 Tine: 11:e7:12 Bakersfield ~ Dept. 1715 Chester Ave. Bakersfield, CA 93301 AMOUNT TANK TESTING 83 COPIES/REPORTS 89 AMOUNT TENTS, LPG 84 FIREWORKS, POWDER, 84 OTHER PERMITS OTHER TO'I:AL DUE' ~ · CITY OF BAKERSFIELD OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (661) 326-3979 APPLICATION TO INSTALL AND/OR REMOVE ABOVE GROUND STORAGE TANK(S) In conformity with provisions of pertinent ordinances, codes and/or regulations, permission is hereby granted to: [ 2~ (o ~Pr ~ ~ame of Comply Address to display, store~se, operate, sell or handle materials or process involving or creating conditions deemed hazardous to life or proPerty as follows: subject to the provisions and/or limitations as provided. Violation of pertinent ordinances, codes and/or regulations shall void this permit. Issued c[/ i..i [ O ( Permit Denied Date Approved by: Applicant Name (print) Applicant Signature THIS APPLICATION BECOMES A PERMIT WHEN APPROVED WILEY EQUIPMENT COMPANY '~The Lubrication Equipment Specialists Who Listen" 126 ARENA STREET EL SEGUNDO, CA 90245 1-310-640-9093 FAX 1-310-322-4512 SEARS AUTO CENTER INSTALLATION OF ABOVEGROUND OIL TANK 3001 MING BAKERSFIELD, CA 93304 Description of Tanks involved: NEW OIL TANK (CLASS 3B) 1-500 GALLON DW UL-LISTED TANKS (UL142) - 250/250 - TANK IS ABOVEGROUND ATMOSPHERIC TANKS USED ONLY FOR CLASS 3B LIQUIDS THAT ARE PLACED ON THE GROUND FLOOR LEVEL WITH A FILL OPENING THAT IS LOCKABLE. -CONTAINMENT IS THROUGH THE DOUBLE-WALLED CONSTRUCTION OF THE TANKS. -TANK IS LOCATED WITHIN THE BUILDING, OUT OF REACH OF THE GENERAL PUBLIC AND THE AREA IS LOCKABLE. -VISUAL MONITORS ARE PROVIDED TO MONITOR OIL LEVEL. -DAILY VISUAL MONTORING WILL BE CONDUCTED. -WARNING PLACARDS, SIGNS, AND FIRE EXTINGUISHERS WILL BE PROVIDED. -SEISMIC HOLD-DOWNS WILL BE PROVIDED. -EMERGENCY VENTING IS PROVIDED AS PER 7902.2.2.6.5.1 WITH EXCEPTION FOR STATIONARY ATMOSPHERIC TANKS CONTAINING CLASS 3-B LIQUIDS. WILEY EQUIPMENT COMPANY '~l'he Lubrication Equipment S~ecialists Who Listen'" 126 ARENA STREET- EL SEGUNDO, CA 90245 1-310-640-9093 FAX 1-310-322-4512 18 O0 08: 24p Mike Sands DEC-~5-2~8~ 16:49 'FROM GRACO LUBE EQUIPMENT S INDusYRIE~,'INC. · 'Peninsula;Drive Northeaxt, MD 21 gO1 TOHMY -528-68'73 TO ' M) KE SANDS P. 02/88 :Phone: {~800) 253.8265 (¢10) 287-0514 Fa-X: C4i0) 287.2445 p.3 SPECIFICATIONS SINGLEWALL , DOUBLE WALL ( SECONDARY CONT~ ,1~ ) ABOVEGROUND TANKS FOR FI~IMABLE AND. COMBUSTIBI,E LIQUILDS NON-FIRE RATED MAX/1998. 1.0 Tank Descriptiou: ' 1.1 1.2 1.3 1,4 1.5 1.6 1.7 Tommy Tar~ ate design:d, consm~ct¢~ rout t~,,u~'ki;acc°rdau Under-,vt, ire, rs Lab0ralnries. In¢, .gtandar~ _1_.<~. "' Stccl Abovegrou.ud Tanks for Fiauu:uabie and eom' .bU.S. ~b!e Liquids. atmospl:~tSc tanks of The National Fire Protectioa. AsS~ciatkm Secdona 30, 30A, md 31 as well as The Urdto._~rn F~ Codeit'UFQ)'Artiel* 79, Tommy Tanks are designed ard listed as armochem tanks ',wi;th maximum working preagae of 1 Pound Per SqUare Iaeh (PSI). Tommy Tanks shall have passed a proof of desigu ky.d~stat[0 test of 25 PSI for tho primary ~d secondary con~nm~t tanks. Eaoh l~mar)' tank shall hax'e on'~ ~nea'$ellcy veil. t UL arut four addktonal fitthags for t. he mourning an~ :i2~allafiou of equipm~t. · Each secondary tank (double w~l clesiga) shall haw}one fitxLng-~ required by UL and one Mdidor~l fitti~ for interstitial ' monitoring and venting. Each tank shall be equipped with ILefi~tg lu~. Tommy Tanks ineluc~ an Eighteen Months Warnn~} from ct~¢.of purrhase~ Dec i8 O0 08:24p Mike Sands DEC-05-2000 16:49 FROM GRACO LUBE EQUIPMENT S 714-528'~-G873 TO MIKE SANDS R.03/08 p.4 3¸.0 Single Wall Tanka (Primary Storage Tank) 2,1 2.2 Each pdrnary tank will b~ o~'rectangul Emgh Single Wall tank shall Se construetea21 ot ~'TM A-569 or A-36 Carbon sl~, ASTM A-240 ~, or 304,3:16 ~lMess s~eL Asrequil, ed regarding produd eompm"ibility. 2.3 Em:h Single W~ tank,shall be f~ctory pre.~;$ure tesu~:per UL 1.42 specification at 3 ~o 5 PSI. 2.4 E_ach Sh~g), Wall tank exterior shall have one eom Ofi'ed oxide primet. Double W~II Tanks (S4v~n(Lax'y'Contmiamen{ Tan~). : 3.1 Each secondary conlainment tank w/Il be ofrecms~ular design. 3.2 3.3 3.4 3.5 Eac. h soeoadary ¢onla.i. amera tank flutlJ be listed, by Undezwziters Laboratories ~ a serene'cogent m~ ~ch ,econ~ e~ment ~ ~ ~v,= a mi~mm of t 10%: ~ch s~co~ con~ent ~ ~1 ~ eon~'OfAS~.A-569 or ASTM A-240 ~e 142 ~eifi~tion at 3 PSI. 3.6 Each seoond~?' containment tank ext~rio'r slmll Mve one coat of red o>dde primer. 25O' t 2~0 c_~ t C, AU_ONS I t I PRItlIER: ~[D OX1DE .TOP L-'OA'1':' RED ENAMEL CITY OF BAKERSFIELD OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (661) 326-3'979 APPLICATION TO INSTALL AND/OR REMOVE ABOVE GROUND STORAGE TANK(S) In conformity with provisions of pertinent ordinances, codes and/or regulations, permission is hereby granted to: [ 2. Name of Company Address to display, store~se, operate, sell or handle materials or process involving or creating conditions deemed hazardous to life or property as follows: subject to the provisions and/or limitations as provided. Violation of pertinent ordinances, codes and/or regulations shall void this permit. Issued '9/'[ Permit Denied I'1 Date Approved by: Applicant Name Applicant Signature THIS APPLICATION BECOMES A PERMIT WHEN APPROVED