Loading...
HomeMy WebLinkAboutUNDERGROUND TANK (2)FIRE CHIEF RON FRAZE ADMINISTRATIVE SERVICES 2101 'H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 SUPPRESSION SERVICES 2101 "H" Street Bakersfield, CA 93301 VOICE (661) 326-3941 FAX (661) 395-1349 PREVENTION SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3951 FAX (661) 326-0576 ENVIRONMENTAL SERVICES 1715 Chester Ave. Bakersfield, CA 93301 VOICE (661) 326-3979 FAX (661) 326-0576 TRAINING DIVISION 5642 Victor Ave. Bakersfield, CA 93308 VOICE (661) 399-4697 FAX (661) 399-5763 D April 12, 2002 FLEET CARD FUELS 7030 SCHIRRA CT BAKERSFIELD, CA 93313 Re: Enhanced Leak Detection Requirements REMINDER NOTICE Dear Owner/Operator, The purpose of this letter is to remind you about the new provision in California law requiring periodic testing of the secondary containment of underground storage tanks. Your facility has been identified as not having secondary containment on at least one of your underground storage tank components and as such falls under section 2637.(1) of the Califomia Code of Regulations, Title 23, Division 3, Chapter 16; As an alternative, the owner or operator may submit a proposal and workplan for enhanced leak detection to the local agency, by July 1, 2002; complete the program of enhanced leak detection by December 31, 2002; and replace the secondary containment system with a system that can be tested in accordance with this section by July 1, 2005. The local agency shall review the proposed program of enhanced leak detection within 45 days of submittal or re-submittal." Please be advised that there are only a few qualified testers available to perform "Enhanced Leak Testing". All testing must be under-permit through this office. For your convenience, I am enclosing a copy of the code as a reference. Should you have any additional questions or concerns, please feel free to call me at (661)326-3190. Sincerely, Ralph Huey Director of Prevention Services Steve Underwood Fire Inspector/Environmental Code Enforcement Officer Office of Environmental Services SU/kr Enclosures ~ ;:,TEl I SETUP FEB 2:2, '20CI2 2:03 PM SYSTEM UNITS U.S. SYSTEM LANC~UAGE E NGL I S H SYSTEM DATE..."T IME FORI"I2T MON DD YYYY HH:MM:SS xM F.C.F. 48 7030 SCHRRR CT. BAKERSFIELD CA. 661 396 84~1 SHIF'F TIME 1 SHIFT TINE 2 : DISABLED SHIFT TINE 3 : DISABLED SHIFT TIME 4 : DISABLED TNNK PER TST NEEDED WAN D I SABLED TANK ANN TST NEEDED WAN D I SABLED LINE RE-ENaBLE METHOD PASS LINE TEST LINE PER TST NEEDED WAN D I SABLED LINE ANN TST NEEDED WAN D I SABLED PRINT TC VOLUMES ENABLED TEMP COMPENSATI VALUE (DEC F ): ST ICK HE I GHT OFFSET D I SABLED H-PROTOCOL DATA FORMAT HEIGHT DAYLIGHT SAVING TIME ENABLED START DATE APR WEEK 1 SUN START TIME 2:00 ~M END D~TE OCT ~EEK 6 SUN END TIME 2:00 ~M RE-DIRECT LOCAL PR 1NTOUT D I B~BLED EURO PROTOCOL PREFIX SYSTEM SEC;UR ITY ,:]ODE : 000000 COMMUIi I CAT IONS SETUP PORT SETT I NOS: COMM BOARD : ~ ~F,.~,I , BAUD RATE : 2400 PARITV : ODD STOP BIT : 1 STOP DATA LENGTH: ? DATA RS-232 SECURi TV CODE : DISABLED DIAL TYPE : TONE ANSWER ON : 1 RING MODEM SETUP STRING : DIAL TONE INTERVAL: 32 RECEIVER SETUP: D i:NTL 9289045 RCVR TYPE: FACSIMILE PORT NO: 2 RETRY NO: 3 RETRY DELAY: 3 CONFIRMATION REPORT: OFF D 2:FCF 3230126 RCVR TYPE: FACSIMILE PORT NO: 2 RETRY NC>: 3 RETRY DELAY: 3 CONFIRMATION REPORT: OFF D 3:CVE 3252529 RCVR TYPE: FACSIMILE PORT NO: 2 RETRY NO: 9 RETRY DELAY: 3 ~ CONFIRMATION REPORT: OFF D 4:CVE-ANS. SEA. 3933336 RCVR TYPE: FACSIMILE ' PORT NO: 2 RETRY NO: 3 RETRY DELAY: :3 CONFIRMATION REPORT: OFF AUTO DIAL TIME SETUP: D I:NTL DIAL DAILY DIAL TIME : 6:00 APl RECEIVER REPORTS: SYSTEM STATUS IN-TANK STATUS INVENTORY DELIVERY D 2:FCF DIAL DAILY DIAL TIME : 6:00 AM RECEIVER REPORTS: SYSTEM STATUS : IN-TANK STATUS : INVENTORY : DELIVERY : LAST DELIVERY : D 3;CVE DIAL ON DATE FEB 22, 2002 DIAL TIME : DISABLED RECEIVER REPORTS: D 4:CVE-ANS. SER. .-'" DIAL ON DATE FEB 22. 2002 DIAL TIME : DISABLED RECEIVER REPORTS: RS-232 END OF MESSAGE DISABLE[:' AUTO DIAL ALARM SETUP D 1 :NTL IN-TANK ALARMS ALL;HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:PROBE OUT ALL:DELIVERY NEEDED D 2:FCF IN-TANK ALARMS ALL:HIGH WATER ALAP''~ ALL:OVER~ILL ALARPI~ ALL:LOW ~RODUCT ALAk-?l ALL:PROBE OUT ALL:DELIVERY NEEDED LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM VAPOR SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT AL~'- ALL:SHORT ALARM ~ D 3:eVE IN-TANK ALARMS ALL:HIGH ~ATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:PROBE OUT LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL;SHORT ALARM VAPOR ~ENSOR ALMS ALL:FUEL ALARM ~LL:SENSOR OUT ~LARM ALL:SHORT ALARM D 4:CVE-ANS. SER. IN-TANK ALARMS ,'~ ALL:HIGH WATER ALA, ALL:OVERFILL ALARMx'-/ ALL:LOW PRODUCT ALARM ALL:PROBE OUT LIOUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM VAPOR SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM L I N-TANK SETOP T i:PREMIUM PRODUCT CODE :' 1 THERMAL COEFF :.000700 TANK DIAMETER : 107.75 TANK PROFILE : 1 PT FULL VOL : 15227 FLOAT SIZE: 4.0 INS WATER WARNING : 2.0 HIGH WATER LIMIT: 4.0 MAX OR LABEL VOL: 15227 OVERFILL LIMIT : 90% : 13704 HIGH PRODUCT : fi~. : 192, DELIVERY LIMIT : 26~ : 3045 LOW PRODUCT : 300 LEAK ALARM LIMIT: 99 SUDDEN LOSS LIMIT: 999 TANK TILT : 0.00 MANIFOLDED TANKS T~: NONE LEAK MIN PERIODIC: 20% : 31345 LEAK MIN ANNUAL : 40% : 6090 PER I OD I C TEST TYPE ANNUAL TEST FAIL ALARM DISABLED PER I OD I C TEST FA I L ALARM DIGABLED (:;ROSS TEST FA I L ALARM DI GABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: TNK TST SIPHON BREAK:OFF DELI VERY DELAY : 3 MI N T 2:UNLEADED PRODUCT CODE : 2 THERMAL ¢OEFF :.000700 TANK DIAMETER : 107.75 TANK PROFILE : 1 PT FULL VOL : 1~R27 FLOAT SIZE: 4.0 IN. ~ATER WARNING : 2.0 HIGH WATER LIMIT: 4.0 MAX OR LABEL VOL: 15227 OVERFILL LIMIT : 90% : 13704 HIGH PRODUCT : 87% : 47 DELIVERY LIMIT : 0% : 3045 LOW PRODUCT : 300 LEAK ALARM LIMIT: 99 SUDDEN LOSS LIMIT: 999 TANK TILT : 0.00 MANIFOLDED TANKS T~: NONE LEAK MIN PERIODIC: 20% : 3045 LEAK MIN ANNUAL : 40% : 6090 PERIODIC TEST TYPE ANNUAL TEST FAIL ALARM DIGABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AWERAGING: OFF PER TEST AVERAOING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK 'F DEL IVERY DELAY : 3 M I N T 3:DIESEL PRODUCT CODE : 3 THERMAL COEFF :.000460 TANK DIAMETER : 107.75 TANK PROFILE : 1 PT FULL VOL : 15227 FLOAT SIZE: 4.0 WATER WARNING : 2.0 HIGH WATER LIMIT: 4.0 MAX OR LABEL 'VOl,: 15227 OVERFILL LIMIT : 13700 tiIGH PRODUCT : DELIVERY LIMIT : 20% : JO~5 LOW PRODUCT : 300 LEAK ALARM LIMIT: 99 SUDDEN LOGG LIMIT: .999 TANK TILT : 0.00 MANIFOLDED TANKS T~: NONE LEAK MIN PERIODIC: 20% : 3045 LEAK MIN ANNUAL : 40% : 6090 PERIODIC TEST TYPE .~'-- ANNUAL TEGT FAIL ALARM DISABLED PERIODIC; TEST FAIL ALARM DISABLED GROSS ]'EST FAIL ALARM DISABLED ANN ]'EST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TGT SIPHON BREA,.._flFF DELIVERY DELAY : 3 M I N LEAK TEST METHOD TEST ON DATE : ALL TANK JAN 1, 1996 GTART Tilde : DISABLED TEST RATE :0.20 GAI-'MR DURATION : ~ HOU T~T EARLY STOP:DISABLED LE~t: TEST REPORT FORMAT NORMAL LIaUID SENSOR SETUP L I:PREMIUM-STP TRI-STATE (SINGLE FLOAT) CATEGORY : STP SUMP L 2:PREMIUM-ANNULAR TRI-STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE L 3:PREMIUM-SUMP TRI-STATE (SINGLE FLOAT) CATEGORY : PIPING SUMP L 4:UNLEADED-STP TRI-STATE (SINGLE FLOAT) CATEGORY : STP SUMP L 5:UNLEADED-ANNULAR TRI-STATE (SINGLE FLOAT) CATEGORY': ANNULAR SPACE L G:DIESEL-STP TRI-STATE (SINGLE FLOAT) CATEGORY : STP SUMP L 7:DIESEL-ANNULAR TRI-STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE L 8:DIESEL-9-SATALITE TRI-STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN L 9:DIESEL-9-10-DISP. TRI-STATE <SINGLE FLOA~'- CATEGORY : DISPENSER LIO:DIESEL-IO-SATALITE TRI-STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN Lll:PREM.-UNL.-EAST SUMP TRI-STATE <SINGLE FLOATL CATEGORY : PIPING SUMP L1Z:PREM-UNL-WEST SUMP TRI-STATE (SINGLE FLOAT) CATEGORY : PIPING SUMP LiJ:PREM-UNL NORTH SUMP TRI-STATE (SINGLE FLOAT) CATEGORY : PIPING SUMP- L14:MPD-5-6-PAN TRI-STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN L15:MPD-1-2-PAN TRI-STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN L16:MPD-7-8-PAN TRI-STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN L17:MPD-S-4-PAN TRI-STATE (SINGLE F: CATEGORY : DISPENSER VAPOR SENSOR SETUP> V I:PREMIUM-VAULT SENSOR THRESHOLD: 2500 CATEGORY : ANNULAR SPACE V 2:UNLEADED VAULT SENSOR THRESHOLD: 3040 CATEGORY : ANNULAR SPACE V 3:DIESEL VAULT SENSOR THRESHOLD: '~'='00 CATEGORY : ANNULAR OUTPUT RELAY SETUP R I:PREMIUM-STP TYPE: STANDARD NORMALLY CLOSED IN-TANK ALARMS T I:H1GH WATER ALARM T I:LOW PRODUCT ALARM LIQUID SENSOR Al. MS L I:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM Lll:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM LI7:FUEL ALARM L I:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM Lll:SENSOR OUT ALARM L12:SENSOR OUT ALARM LIS:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SEN~OR OUT ALARM L I:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM Lll:SHORT ALARM L12:$HORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM R 2:UNLEADED-STP TYPE: STANDARD NORMALLY CLOSED 1N-TANK ALARMS T 2:HIGH WATER ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 4:FUEL ALARM L 5:FUEL ALARM LII:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM LII:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L 4:SHORT ALARM L 5:SHORT ALARM Lll:SHORT ALARM L12:SHORT ALARM LIS:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM LI6:SHORT ALARM L17:SHORT ALARM R 3:DIESEL-STP TYPE: STANDARD NORMALLY CLOSED IN-TANK ALARMS T 3:H~GH WATER ALARM T 3:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM LIO:FUEL ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALAP~' L B:SENSOR OUT ALP / L 9:SENSOR OUT ALA~ LIO:SENSOR OUT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM LIO:SHORT ALARM R 4:REMOTE ALARM TYPE: STANDARD NORMALLY CLOSED IN-TANK ALARMS ALL:OVERFILL ALARM RECONCILIATION SETUP AUTOMATIC DAILY CLOSfNG TIME: 2:00 AM PERIODIC RECONCILIATION MODE: MONTHLY TEMP COMPENSATION STANDARD BUS SLOT FUEL'METER TANK TANK MAP ElflPTY ..... SENSOR AI.ARN '-- L I:PREMIUIfl-STP STP' SUMP FUEl.. ALARM FEB 22, 2082 2:17 PM L 2:PREMIUM-AIqNIJLAR ANNULAR SPACE FUEL ALARM FEB 22, 2002 2:17 PM ..... SENSOR ALARM L 3 :PREMI UPI-SUMP PIPING SUMP' FUEL ALARM FEB 22. 2002 2:18 PM ..... SENSOR ALARM ...... L 4:UNLEADED-STP STP> SUMP' FUEL ALARM FEB 22, 2002 2:19 PM ..... SENSOR ALaRrl ...... L ?:DIESEL-ANNIJLAR ANNULAR SPACE FUEL ALARM FEB 22, 2002 2:20 PM L 5:UNLEADED-ANNULAR ANNULAR SPACE FUEL ALARM FEB 22.." 2002 2:21 '------------- SENSOR ALARM LI:3:I::'REM-UNL NORTH SUMP PIPING SUMP FUEL ALARM FEB 22, 2002 ~:o:22 PM ..... SENSOR ALARM ..... L13;PREM-UNL NORTH SUMP PIPING SUMP FUEL ALARM FEB 22, 2002 2:22 ..... SENSOR ALARM ..... L 7:DIESEL-ANNULAR ANNULAR .~_.E FUEL ALARM FEB on=~, 2002 ~'?:25 PM ..... SENSOR ALARM ..... LIO:DIESEL-IO-SATALITE DISPENSER PAN FUEL ALARM FEB 22, 2002 2:24 PM ...... SENSOR ALARM ..... L 9:DIESEL-9-10-DISP. DISPENSER PAN FUEL ALARM FEB 22, 2002 2:24 PM ..... SENSOR ALARM ..... L 6:DIESEL-STP STP SUMP FUEL ALARM FEB 22, 2002 2:25 PM ...... SENSOR ALARM L S:DIESEL-9-SATALITE DISPENSER PAN FUEL ALARM FEB 22, 2002 2:25 PM ..... SENSOR ALARM ..... L17:MPD-S-4-PAN DISPENSER PAN' FUEL ALARM _jiEB 22. 2002 2:26 PM ..... SENSOR ALARM L12:PREM-UNL--~EST SUMP PIPING SUMP FUEL ALARM FEB 22, 2002 2:27 Ptl ..... SENSOR ALARM L11 :PREM.-UNL.-EAST SUMP PIPING SUMP FUEL ALARM FEB 22, 2002 2:27 PM ..... SENSOR ALARM ..... L16: MPD-7-S-PAN DISPENSER PAN FUEL ALARM FEB 22, 2002 2:28 t::'M ..... SENSOR ALARM ..... L15 ;MPI:i- 1 -2-PAN DISPENSER PAN FUEL ALARM FEB 22., 2002 2:28 PM ..... SENSOR ALARM '---/-- L 14 :MPD-5-B-PAN DISPENSER PAN FUEL ALARM FEB '2'2. 2002 _~&Pd__--- F.C.F. 48 7030 SCHARR CT. BAKERSFIELD CA. 661 396 8431 FEB 22.. 2002 9_:32__ PM _ ~ SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL CITY OF BAKERSFIELD FIRE DEPARTMENT ICE OF ENVIRONMENTAL SERVICES 1715 CHESTER AVENUE BAKERSFIELD, CALIFORNIA 93301 CITY OF BAKI~SFIELD OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (661) 326-3979 INSPECTION RECORD POST CARD AT JOB SITE Permit INSTRUCTIONS: Please call for an inspector only when each group of inspections with the same number ate ready. They will mn in consecutive order beginning with number I. DO NOT cover work for any numbered group until all items in that group are signed offby the Permitting Authority. Following these instructions will reduce the number of required inspection visits and therefore prevent assessment of additional fees. TANKS AND BACKFILL INSPECTION [ DATE [ INSPECTOR Backfill of Tank(s) SparktestCenificati°n°rManufactumsMemod~¢lOLO 4fait (~((d("~ Cathodic Protection of'Tank(s) 'lNG SYSTEM [ Piping & Raceway w/C°llecti°n Sump t'r,,~,,,~ Co.sion Pmt~tion ofP?ping, Join~, Fill Pi~ I El~tffcal Isolation of Pip~g From T~k(s) Cath~ic Proration System-Piping SECONDARY CONTAINMENT, C [, LEAK DETECTION Liner Installation - Tank(s) Liner Installation - Piping Vault With Product Compatible Sealer Level Gauges or Sensors, Float Vent Valves Leak Detect0ffs) for Annual Space-O.W. Tank(s, Monitoring Well(s)/Sump(s, - H20 Test Leak Detection Device(s) for Vadose/Omundwater Spill Prevention Boxes FINAL , CONTACT 4'~L~N Or ~JJ~ PHONE# 3a'~' q3q[ OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (805) 326-3979 PERMIT APPLICATION TO CONSTRUCT/MODIFY UNDERGROUND STORAGE TANK TYPE.,OF APPLICATION (CHECK) iV]NEW FACILITY [ }MODII:ICATION OF FACILITY [ ]NEW TANK INSTALLATION AT EXISTING FACILITY STARTING DATE ~-~ ~ ~ -~ O 1 PROPOSED COMPLETION DATE /O '- 2 ~' - O / FACILITYNAME ~ L e e_-t.¢~ /~o l~r,l~{ ~ EXISTINOFACILrI'YP~NO. FACILITY'ADDRESS q/350 ~c~!r~'O, t~. C1TY"~O~z~.r~'-~.~JA ZIPCODE TYPE OF BUSINESS ~:L~'[\~ -~.o.C(~ t't-'-/ APN# TANKOWNER /_~)C//~-~ c-ogt)x' ~'o , ' FHONENO. ADDRESS ~_Z~O' K~ ~.'f~-~ M/~8 crrv ~ ~'~_ z~ CODE. CONTRACTOR ~'~{.~- \[~ t ~-~ ~c~-. CA LICENSE NO. '[ ~ I~'O ~ PHONE NO. (~o ¢~, { _ ~'~_'7~'7_ - ~/~ ~-~-~ ~ BAKERSFIELD CITY BUSINESS LICENSE NO. WORKMAN COMF NO. INSURER BRI~LYDESCRIBE THE WORK TO BE DONE, ~_~,_ ?z~(~_ t,4 c~ ct ~ --W"x). t,,~'~. .....; t~%; v~x~. WATER TO FACILITY PROVIDED BY DEPTH TO GROUND WATER SOIL TYPE EXPECTED AT SITE NO. OF TANKS TO BE INSTALI.FD '~ ARE THEY FOR MOTOR FUF_~ " SPILL PREVENTION CONTROL AND COUNTER MEASURES PLAN ON FILE ~-' YES, ' "' NO YES No SECTION FOR MOTOR FUEL TANK NO. VOLUME UNLEADED REOULAR PREMIUM eO~,L- DIESEL AVIATION · 'Z- ~ ~. r.w~O ~ TANK NO. VOLUME s~.c~io~ ~OR ~o~ MOTOR ~Y~L STO~O,a~ TANKS CHEMICAL STORED CAS NO. CHEMICAL PREVIOUSLY STOREJ) (NO BRAND NAMr) 0~ KNOWN) FOR OFFICIAL USE ONLY i THE APPLICANT HAS RECEIVED, UNDERSTANDS, AND WILL COMPLY WITH THE ATTACHED CONDITIONS OF TH/S PERM1T AND~ANY OTHER STA'[~, LOCAL AND FEDERAL REGULATIONS. 8-27-2881 3:OOPN FRON :ALVALLEY EQUIP 16613252529 P. 1 CAL-VALLEY EQUIPMEN'I' ""'~500 GILMORE AVE (66'I) 327-934 '1 Fax: (66'1) 325-2529 Conhaclor's Llc,tt 784 ~ 70 A I fAZ Fro~t~: o ,. '°' ."SC' c._~'~"hi ._.C~;,~' ...-E~ ........................... Jrt, ~ ~t Arr': .C%-T~ ~/~, I..'. , no, _L.L, f.- * L ( ~.~.~_~,LA:S ........ cc.. 8-27-2001 3:01PM FROM CALVALLEY EQUIP 16613252B29 P. 2 sTA~TE WATER RESOURCES CONTROL BOARD . I:X)e4:I~k~N OF .C,~,,~',AN WATER PROGF),AMS ~I'14..T S'VSi~ET, $i~lT'~ '~;30 N~'. IUch~d Lewis, Vice-President Wesmm l:ibergJass, ~c. l ~55 ~p~U P~ay S~ Ro~ CA 95403 Dear Mr. Lewis: CONT]AMATION O1: I~_.CglPT 01: THIRD-pARTY REPORTS ON ~ERGROUND STORAGE TANg: (UST) EQTu~~. This lette~ iS WTjtten to cord~rm that we have received independent third-party reports of the following products manufacTu, red by Western Fiberglass: DisPenser Mounting A~s~mbly (DMA) Series Emergency Valve Mounting Frame System from Underwriters Laboratory, Inc. dated October 1, 1993, U.L. reference M:H! 7921, 93NK22529. Dispenser Mounting Assemble (Dlgf. A) from the CLARK GROUP dated October 1, 1991. Sump Assemble fi'om the CLARK GROUP dated October 1, 1991. ~LASH-GAJLD Flame Suppressant System from Robert H. Lee and Associates, Inc. dated July 8, 1994. We appreciate your subrrtittal of these documents as was requested in a March 14, 1994 letter to UST equipment ma~ufacturers~ As you may recall, an explanation wa~ provided in that lette, r as to why we requested th. is L, fformation. As stated, the State Water Resources Control Board da,es · not review or maintain an o~¢ial list of third-party reports on UST equipmen.t, or components. However, since we receive .inquires regarding the subject, u,,e want to be in a position to readily pass this information on to the local agencies. If you h~,ve any questions regarding this issue, please cfll John Welch at (916) 227-4323 or me at (916) 227-4332. ,/ Sincerely. David Holtry~ Engineering Unit Underground Storage Tank Program LOS ANGELES RRE DEPARTMENT BUREAU OF FiRE P, REVENTI01~ 8-27-2001 3:01PM FROM CALVALLEY EQUIP 166132B2B29 P. 3 ® Tech-Notes Third Party Testing Issue 106A © 1998 Advanced Polymer Technology, Inc. May 1998 Third Party Testing APT performs rigorous in-house testing on all compo- nents developed and manufactured 'by APT. To affirm that we meet or exceed physical installation and environmental security requirements, APT also documents pertbrmance specifications through third-party testing laboratories. 'l'csting wa~ performed on Poly-TcchTM pipi~)g by L, J, Broutmm'~ and Southwest Research. The purpose here was m demonstrate that Poly-TechTM piping products were in compliance with the fbllowing standards fbr all current fi~els- including alcohols and gasoline/alcohol blends. A detailed engineering report is available upon request. Underwriter's Laboratory Standard 971 Nonmetallic Underground Piping for Flammable Liquids · National Fire Protection Association Code 30 Flammable and Combustible Liquids · American National Standards Institute B31.4 Liquid Transportation Systems for Hydrocarbons, Liquid Petroleum Gas, Anhydrous Ammonia, and Alcohol · BOCA National Fire Prevention Code Article 28 Flammable and Combustible Liquids o American Society for Testing of Materials D2513 Standard Specification for Thermoplastic Gas Pressure. Pipe, Tubing and Fittings Mechanical Test Results Summary · Leakage Passed at 200 psi (2X rating) · Hydrostatic Strength Passed at 500 psi (SX rating) · Burst Over 800 psi (primary piping) Over 70 psi (secondary Jacket) 350,000 Cycle Line Shock Passed 350,000 cycles at 100 psi after first undergoing leakage test · Change in Length Under Pressure 0.07% from 0-50 psi 0.16% from 0-100 psi 0.28% from 0-200 psi · Sustained Pressure / Long Term Strength Acceptable continuousstress over a fifty (50) year period --- 375 psi · Tensile (pull) 2,2:29 pounds force · Resistance to Crushing Primary passed Secondary passed Environmental Test Results Summary Permeation Fuel C 0.007% 90% Fuel C, 10% Ethanol 0.007% 90% Fuel C, 10% Methanol 0.007% 50% Fuel C, 50% Methanol 0,021% Ethanol 0.028% Methanol 0.036% Diesel Fuel 0.035% Methyl Ethyl Ketone (MEK) 0,021% Toluene 0,014% UL 971 Maximum Allowable Permeation = 1,000% Fuel Immersion Fuel C Passed 90% Fuel C, 1'0% Ethanol Passed 90% Fuel C, i0% Methanol Passed 50% Fuel C, 50% Methanol Passed Ethanol Passed Methanol Passed Diesel Fuel Passed Methyl Ethyl Ketone (MEK), Passed Toluene Passed Passed leakage, hydrostatic strength and burst tests after exposure to test fluids. 8-27-2001 3:02PM FROH ;ALVALLEY EQUIP 16613202029 Advanced Flexible Underground Piping System Environmental Security r-I Ease of Installation Cost Effectiveness Warranty: The sefler warrants that all materials supplied by A.P.T., lac. will be free from defects for a period of (30) years. Seller will repair or replace, at it's option, components verified to have manufacturing defects. Seller will reimburse approved labor costs for repair of defective products. A.RT. products must be installed by factory certified installers, and an A.RT. warranty form must be submi~ed. Warranty does not cover Acts of God, accidents, negligence or consequen- tial damages arising from any defects in the components. The warranties detailed above are the only warranties made by seller, and are expressly in lieu of all other warranties, expressed or implied, including the warranties of merchant- ability and fitness for particular use. Installer Training: Installation training is available by attending a Poly-Tech installation. training seminar conducted by a factory trained installer or via APT's installation' training course available on video. APT identifies factory trained installers by a certification card given upon completion of its course. Failure to comply with 'these instructions will void all warranty. Poly-Tech systems are to.be installed in strict accordance with all applicable Federal, State and local regulations. Contact APT at (800) 262-9899 for information on attending a Poly- Tech installation training seminar or tO purchase the installation training course on video. UL/ULC Listinq$: P-175-D piping P-175-SC piping MS-175 male swivel fitting FS-175 female swivel fitting ULC Listed. P-175-D piping P-175-SC piping S-175-D piping S:175-SC piping MS:175 ma~e swivel fi~ing FS-175 female swivel titling PTDS spilt dispenser sump PTDP dispenser pan TS-4242 tank sump TS-4230 tank sump TS-3630 tank sump IPS-3636 intermediate piping sump IPS-2424 intermediate piping sump Advanced Polymer Technology, Inc. 2817 McCracken Avenue Muskegon, MI 49441 Ph: (800) 262-9899 Fax: (616) 759-3173 Distributed by: (~) ~997, APT, Inc. Publication: Installation Effective Date: 12/97 8-27-2001 S:O6P~ FROM CALVALLEY EQUIP 166132~2B29 P. 2 MOSIER BROS. ..... · ........ Telepl.~ne: The T~nk Buitdem FAX: (559) ($59) 564-3305 Cai-Valley EquiPment F~.x: 661-325-2529 August 27, 2001 Dea~ Mr. Pe~L As per oar discuSSion this m~ming, tl~ 15,000 gallon tat~ for the Davies job will 1~ UL 142 listed. Thc tar~ks shall bear the label - UndcrwriteL~ Laboratories list~<l Abovcground Tank for Flammable Liquids. AS otbor quv-stions ari,~, lalcasc call SiteFax, Veeder-Root's programmable Auto-Dial fax and modem capability for the TLS-350R and TLS-350, lets you transmit important inventory, alarm and status information from the TLS-350R and TLS-350 directly to fax machines or persona~ computers -- automatically, anytime, day or night. Provides Communicatio~ fl~lerface for r~emote Conh'olTM software Automatically fax reporls fi'om 'I'LS~3501~ or 7'LS-350. Up lo 8 programmable phone numbers. · Programmable calling times for each Up to 16 reports can be l~ansmil~ed to each numbe~; h~cluding: · System siatus. · hTventory. · Defiveries. · Tank and line leal( test result:s. · Sensor stalus. · Alarm histories. Selectable caflh~g schedule for each number: · Daily. · Weekly. · Monthly. · Yearly. , On a specified date. Selectable automalic dialing to report a~y a/arm conditions flnmediately: · In-tank leak alarms. · Lfi~e leak alarums. · Leak sensor · External In~uts. Selectable Fa~Compute~eletype compatibility. Ideal for remote generator locations and commercial operations. Combh~ed with Fuel Manager and BIR, provides a powedul busfi~ess management tool It speeds up and simplifies reporting, helps you keep a closer watch on your operation, and lets you respond more quickly to alarm conditions that may occur. All you have to do is enter the fax numbers you want called, select the repods to transmit to each number, enter the time and schedule for each call, and select which alarm conditions will trigger the immediate Auto-Dial Alarm. It's that simple. Its redial feature makes sure the call gets through if the fax is busy. With the programming ability to select specific reports for each fax number, you can tailor your fax reporting to the specific needs of your operation. For example, you could send: · inventory, shift and delivery reports to a district sales office. · Inventory reports to a delivery scheduler. · System and sensor status reports to a maintenance or service office. · Alarm messages to a security monitoring service. · All reports to a headquaders location. In addition, SiteFax can be programmed to call computers and teletype machines, making it capable of transmitting data to the vast majority of industry- standard telecommunications devices. SiteFax. The simplest, fastest, and most efficient way to stay in touch with your fueling site and retail operations. SiteFax, Veeder-Root's programmable Auto-Dial fax and modem capability for the TLS-350R and TLS-350, lets you transmit important inventory, alarm and status information from the TLS-350R and TLS-350 directly to fax machines or personal computers -- automatically, anytime, day or night. Provides Communication flIle/f.~ne for I~em~.e Co~7lrolTM soflware Automatically fax reporls fi'om 7'LS-3501~ or TLS-350. Up ~o 8 programmable phone * Programmable callh~g ~hnes for each number. Up ~o 16 reports can be ~nsmi~led ~o each number; fl~cluding: * Sysiem sh~{us. * fl~ven~ory. * Deliveries. * Tank and line leak ~es~ results. * Sensor s~a~us. * Alarm histories. Selectable calling schedule for eacl~ number: * Daily. * Weekly. . Monfl#y. * Yearly. * On a specified date. Selectable automatic dialing ~o report any alam~ conditions flnmedia~ely: * In-tank leak alarms. * Lfl~e leak alarums. * Leak sensor ~al717s. * External Inputs. Seleciable Fax/Comguler~ele~ype compalibiliiy. Ideal for remote generator locations and commercial operations. Combined ~i~l~ Fuel Manager and BIR, provides a powerful busfl~ess management tool. It speeds up and simplifies reporting, helps you keep a closer watch on your operation, and lets you respond more quickly to alarm conditions that may occur. All you have to do is enter the fax numbers you want called, select the repods to transmit to each number, enter the time and schedule for each call, and select which alarm conditions will trigger the immediate Auto-Dial Alarm. It's that simple. Its redial feature makes sure the call gets through if the fax is busy. With the programming ability to select specific reports for each fax number, you can tailor your fax reporting to the specific needs of your operation. For example, you could send: · Inventory, shift and delivery reports to a district sales office. · Inventory reports to a delivery scheduler. · System and sensor status reports to a maintenance or service office. · Alarm messages to a security monitoring service. · All reports to a headquarters location. In addition, SiteFax can be programmed to call computers and teletype machines, making it capable of transmitting data to the vast majority of industry- standard telecommunications devices. SiteFax. The simplest, fastest, and most efficient way to stay in touch with your fueling site and retail operations. 9-04-2001 11:10AM FROM .LEY EQUIP 1GG132~2B29 STATE WATER 'REsoURCES CONTROL BOARD ~ OF CLEAN WATER PROGRAMS ,,~B14T ~l~Lrt', SUITE 130 P~BOX .~44212 ,( ~iA~ItT, O. CA 9424'4'2120 _~,Wle) 227-434~ Dear Mr. Lewis: CONFIRMATION OF RECENT OF ~-PARTY REPORTS ON UNDERGROUND STORAGE TA.N~ (US'i)EQU~ME,NT This let~e~; is. written to cordirm that We have received independent third-par~y reports of the following products manufactured by Western FibergJass: i. Dispenser Mounting Assembly. (DlVIA). Series Emergency Valve Mounting Frame System from Underwriters Laboratory, Inc. dated October 1, 1993, U.L reference ~ 17921. 93NK22529. Dispenser Mounting Assemble (])MA) from the CLARK GROUP dated October l, 199 l. Sump Assemble from the CLARK GROUP dated October I, 1991. 4. FLASH-GARD Flame Suppressant System from Robert H. Lac and Associates, Inc. dated J'uly 8, 1994. We appreciate your. submitm! of these documents as.was requested in a March 14, 1994 letter to UST equipment manufacturers~ As you may recall, an explanation was provided in that letter as to why wc requested this information. As stated, the State Water Resources Control Board da.es not review or maintain an official list of third-party reports on UST equipmen.t, or components. However, since we receive.inquires regarding the subject, we want to be in a position to readily pass this information on to the local agencies. If you ht~ve any questions regarding this issue, please.call John Welch at (916) 227-4323 or me at (916) 227-4332, ./ Sincerely, David Holtry~ Engineering Unit Underground Storage Tank Program LOS AllELES RRE I~EPARTIdENT BUREAU OF FIRE. P,K'EYENI'!O~ 9-0Zl.-2001 11: 09AM F~I; :ALVALLEY EQUIP 166132B2B29 P.] CAL-VALLEY EEQUIPMEN I' 3500 GILMORE AVE (06'1) 327-934 1 F-ax: (66'1) 32'5-2529 Conbaclor's Lie.t/784 t 70 A t.I^Z [.~ Urgelll ~or ReVlt~W 9-04-2001 11=12AM FROM _EY EQUIP 1~G132~2~29 POMECO 221-AST ABOVEGROUHD STORAGE TAHK SPILL COHTAIHERS The POMECO 221-AST Spill Containers are designed to meet spill container requirements for aboveground storage tanks CAST). The 221 is also lightweight and easy to install and remove making it pardculary well suited for 55 gallon (208 liter) drum and waste oil tank applications. Features e Spun Steel Constn,ction - Eliminates the bottom perimeter weld thus providing the strength of a solid, one-piece unit and promoting a clean, sleek profile. e Choice of Capacities - Available in 3 ~ gallon (13.2 liter) or 7 gallon (26.5 liter) configurations to address a multitude of spill containment applications. * Lightweight Design - At either 19 lbs. (8,6 kg) for the 3.5 gallon models or 23 lbs. (10,4 kg) for the 7 gallon models, thc 221 's are light enough to easily carry to, and install on aboveground storage tanks. These units thread directly onto a 2" or 4" NPT fill riser. * Convenient Product Drainage - A pull-to-open drain valve or an' opti6nal T-plug is available to facilitate quick drainage of spilled product. * Hinged, Loekable Cover- Offers security and convenience. * Corrosion Resistance. Epoxy-powder,ex)at finish provides excellent resistance to hydrocarbons. Standard colors are black or white-other colors available upon request. , Stainless Steel Model - Available upon request for special applications. Materids: Container: Spun Steel Drain Valve: Brass Replacement Parts Pad Ho. Description (:04422 4" Long i:P-I'u9 C04423 ~; ~rt T-Plug .~[~[ 2" Long T-Plu~' ....... C04425 T'~};~t I-Plug P211-VAST POMECO ~, ~W..~ Ordering .Specifications Mo&l Capacity Color Pbg=T Fill Riser A B Weight gd liters Vdve--V NPT in. cm. in. cm. Pus. kg. 6221-AST-W74V 7 26.5 white V 4~ 14~/~" 37 17" 43 23 10.4 6221-AST. B/4V '7 26.5 black V 4" 141~'' 37 17" 43 23 10.4 6221.AST. W74 .7 2&.5 white T 4" 14~,~" 37 17" 43 23 10.4 &221.AST-B74' I 26.5 black I 4" 14~" 37 17" 43 2:? 10.4 ~221-AST-W72V 7 26.5 white V 2" 12V4' 3l i7~ 43 23 10.4 ~221-AST. B72V 7' 2&.5 black' V 2" 121,~" 31 17" 43 23 10,4 6221-AST-W/2 7 263 while T 2" 12r/4'' 31 17" 43 23 10.4 6221-AST-B72 ? 26.5 black T 2" 12~A" 31 17" 43 23 10.4 6221-~AST-W34 3.5 13.2 white T 4" 91/4" 24 17" 43 19 6221-AST-B34 3.5 I3,2. black T 4" 9V4" 24 17" 43 19 83 6221-AST-W32 3.5 13.2 while T 2" 8" 20 17" 43 19 6221-AST-832 3,5 13,2 black T 2" ~;; 20 17" 43 19 8,6 For custom[zed opliorrs~ please conlad your OPW/POMECO ~epresenlcdive for complete ordering information, Telep~o~ (5131870,3217 · {80014~2-2525 * I:~ (5B1870`?18,~ · (8O0) 421-3297 © 1991 (fl'W Fuel;nD Compenen~ * P,O. Box 405803 ": GMflm;. ~o 45240-5003 * hinted ir, USA o 1P221J~T · '11/97 9-O4-2OO1 11:1OAH FRO~iiALVALLEY EQUIP 166152B2B29 P. 3 ® Tech-Notes · Third Party Testing Issue 106A © 1998 Advanced Polymer Technology. lnc, May 1998 Third ,Party Testing APT perfom~s rigorous in-house testing on all compo- nents developed and manufactured by APT. To affirm that we mcct or exceed physical installation and environmental security requir,cments, APl also documents pcrforrnance specifications through third-party testing laboratories, Testing was pedbmaed on Poly-TechTM piping by L. J. Broutman and Southwest Research, The purpose here was to demonstrate that Poly-TechTM piping products were in compliance with the tb[Iowing standards for all curre~at thels- including alcohols and gasoline/alcohol, blends, A detailed engineering report is available upon request, · Underwriler's Laboratory Standard 971 Nonmetallic Underground Piping for Flammable Liquids o National Fire Protection Association Code 30 Flammable and Combustible Liquids · American National Standards Institute B31.4 Liquid Transportation Systems for Hydrocarbons, Liquid Petroleum Gas, Anhydrous Ammonia, and Alcohol · BOCA National Fire Prevention Code Article 28 Flammable and Combustible Liquids American Society for Testing of Materials D2513 Standard Specification for Thermoplastic Gas Pressure Pipe, Tubing and Fittings Mechanical Test Results Summary * Leakage Passed at 200 psi (2X rating) · Hydrostatic Strength Passed at 500 psi (5X rating) Burst Over 800 psi (primary piping) Over 70 psi (secondary jacket) · 350,000 Cycle Line Shock Passed 350,000 cycles a't 100 psi after first undergoing leakage [est · Change in Length Under Pressure 0.07% from 0-50.psi 0,16% from 0-100 psi 0.28% from 0-200 psi * Sustained Pressure / Long Term Strength Acceptable continuous stress over a fifty (50) year period = 375 ps~ · Tensile (pull) 2,229 pounds force · Resistance to Crushing Primary passed Secondary passed Environmental Test Results Summary Permeation Fuel C 0.007% 90% Fuel~ C, 10% Ethanol 0,007% 90% Fuel C, 10% Methanol 0.007% 50% Fuel C, 50% .Methanol 0,021% Ethanol 0.028% Methanol 0,036% Diesel Fuel 0.035% Methyl Ethyl Ketone (MEK) 0.021% Toluene 0.014% UL 971 Maximum Allowable Permeation = 1.000% Fuel Immersion Fuel C Passed 90% Fuel C, 10% Ethanol Passed 90% Fuel C, 10% Methanol Passed 50% Fuel C, 50% Methanol Passed Ethanol Passed Methanol' Passed Diesel Fuel Passed Methyl Ethyl Ketone (MEK) Passed Toluene Passed Passed leakage, hJ/drostatic strength and burst tests after exposure to test fluids. 9-04-2001 1 1 .- 1 1AH FROMeALVALLEY EQUIP 16;6132...E,2¢---,29 Advanced Flexible Underground Piping System Environmental Security Ease of Installation Cost Effectiveness Warranty: The sailer warrants that all materials supplied by A.P,T., Inc. will be free from defects for a pedod of (30) years, Seller will repair or replace, at it's option, components verified to have manufacturing defects. Seller will reimburse approved labor costs for repair of defective products. A.P.T, products must be installed by factory certified installers, and an A, RT. ' warranty form must be submitted. Warran~ does not cover Acts of God, accidents, negligence or consequen- tial damages arising from any defects in the components. The warranties detailed above are the only warranties made by seller, and are expressly in lieu of ali other warranties, expressed or implied, including the warranties of merchant- ability and fitness for particular use,, Installer Training: Installation training is' available by attending a Poly-Tech installation training seminar conducted by a factory trained installer or via APT's installation training course available on video. APT identifies factory trained installers by a certification card given upon completion of its course. Failur~ to comply with these instructions will void all warranty. Poly-Tech systems are to be installed in strict accordance with all applicable, Federal, State and local ,regulations. Contact APT at (800) 262-9899 for information on a~ending a Poly. Tach installation train!ng seminar or to purchase the installation training course on video; Ui./ULC Listings: UL listed products: P-i75-D piping P-175-SC piping MS-175 male swivel fitting FS-175 female swivel fitting tJ.J..Cc_Lis~d. Products: P-175-D piping P-175-SC piping S-175-D piping 'S-I 75-SC piping MS-175 ma~e swivel fitting FS~175 female swivel fitting PTDS split dispenser sump PTDP dispenser pan TS-42~2 tank sump TS-4230 tank sump TS-3630 tank sump IPS-3636 intermediate piping sump IPS-2424 intermediate piping sump Advanced Polymer Technology, Inc. 2817 McCracken Avenue Muskegon, MI 49441 Ph: (800) 262-9899 Fax: (616)759-3173 Distributed by: (~) ~997. APT, Inc. Publication: Installation Effective Date: 12/97 Suoercedes: 0~96