Loading...
HomeMy WebLinkAboutMITIGATION (2) i~ 07/21/92 PAL~ TANK & CONST INC 015-0~000427 ~ Overall Site with 1 ~ ~,5J,g e 1 ~ General Information 1==============================================================================1 I I---------------~------------------------------------------------------------1 I 1 I Location: 2464 S UNION AV Map: 124 Hazard: Unrated II IICommunity: "BFD" RESPONSE AREA" Grid: 17C 1 AOV: 0.011 I 1----------------------------------------------------------------------------1 I 11--- Contact Name ---1------ Title ------1-- Business Phone --I 24-Hour Phone 1 I IIJERRY W PALMER IPRESIDENT 1(805) 834-1110 x 1(805) 834-316911 II I . I() x I() II I 1--------------------1-------------------1--------------------1--------------1 I 11--------------------------- Administrative Data ----------------------------1 I I I Mail Addrs: 2464 S UNION AV D&B Number: I I II City: BAKERSFIELD State: CA Zip: 93307- II 1 I Comm Code: 015-901 "BFD" RESPONSE AREA" SIC Code: I I I I -------------------------------------------------------------------------- 1 I II Owner: JERRY W PALMER Phone: (805) 834-1110 II I I Address: 2470 S UNION AV State: CA I I II City: BAKERSFIELD Zip: 93307- II I 1----------------------------------------------------------------------------1 I I I Summary -------------------------------------------------------------------11 II II I I ABOVEGROUND OILFIELD TANK CONSTRUCTION YARD, WITH A MECHANICS SHOP AT THE I I 1 IE END OF PROPERTY. AN ABOVEGROUND DIESEL TANK IS LOCATED IN THE SE CRNR I I IIOF YARD. II " II II II I 1----------------------------------------------------------------------------11 1==============================================================================1 tOZJ~ ? ~ 07/21/92 , PALUIiR TANK & CONST INC 015-01.i¡¡000427 Hazmat ~entory List in Reference"'mber Order Page 2 ,ó 02 - Fixed Containers on Site Pln-Ref Name/Hazards Form Quantity MCP -------------------------------------------------------------------------------- 02-001 POLYLITE POLYESTER RESIN > Fire. Immed Hlth. Delay Hlth Liquid 55 Moderate GAL -------------------------------------------------------------------------------- 02-002 OXYGEN > Fire. Pressure Gas 1000 Low FT3. .-------------------------------------------------------------------------------- 02-004 ACETYLENE Gas > Fire. Pressure. Immed Hlth, Delay Hlth 20000 High FT3 -------------------------------------------------------------------------------- 02-006 PETROLEUM DISTILLATE > Fire, Immed Hlth Liquid 1000 Moderate GAL .-------------------------------------------------------------------------------- 02-007 COOKS PAINT > Fire, Immed Hlth, Delay Hlth Liquid 75 Moderate GAL --------------------------------------------------------------------------------- 02-008 COOKS COATING EPOXY > Fire. Immed Hlth. Delay Hlth Liquid 70 Low GAL .-------------------------------------------------------------------------------- .~------------------------------------------------------------------------------- 07/21/92 PA~ TANK & CONST INC 015-0~000427 ~2 - Fixed Containers on ~e Page 3 ,;I' ~' Hazmat Inventory Detail in Reference Number Order --------- ---------------------------------------------------------------------- 02-001 POLYLITE POLYESTER RESIN Liquid 55 Moderate > Fire, Immed Hlth, Delay Hlth GAL ----------------------------------------------------------------------- CAS :It: 100425 Trade Secret: No Form: Liquid Type: Mixture Days: 60 Use: FABRICATION .---- Daily Max GAL ----1-- Daily Average GAL --1-- Annual Amount GAL -- 55 I 35.00 . 110.00 ------ Storage -------1 Press 1 Temp -1------------ Location ---------- DRUM/BARREL-METALLIC Ambient Ambient DESIGNATED "HAZ-MAT" FENCED & LO I I ¡AREA - Conc -1---------------------- Components --------------1- MCP --¡List 45.0% ¡Styrene IModeratej 0.1% ¡N,N-Dimethylaniline Moderate ..- ~ ;=~ ~;~i~~~~~ --- - -- -.---------- --- - - - -- - --- - --- ---~:~ -------- - - - ~~ ~~- -~~: -- - --- > Fire, Pressure FT3 ----------------------------------------------------------------------- CAS #: 7782449 Trade Secret: No Form: Gas Type: Pure Days: 365 Use: FABRICATION ..---- Daily Max FT3 ----1-- Daily Average FT3 --1-- Annual Amount FT3 -- 1,000 I 1,000.00 24,000.00 ------ Storage -------1 Press Temp -1------------ Location ---------- PORT. PRESS. CYLINDER IAmbientlAmbientlFRONT BLDG CENTER - FREE STANDIN - Conc -1---------------------- Components ----------~---!- MCP --¡List 100.0% Oxygen , Compressed Low _.._-----~~-----------------------------------------------------------------~--- 02-004 ACETYLENE Gas 20000 High > Fire, Pressure, Immed Hlth, Delay Hlth FT3 ----------------------------------------------------------------------- CAS :It: 74862 Trade Secret: No Form: Gas Type: Pure Days: 365 Use: WELDING SOLDERING Daily Max FT3 ----1-- Daily Average FT3 --1-- Annual Amount FT3 -- 20,000 I 20,000.00 ¡ 200,000.00 ------ Storage -------1 Press I Temp -1------------ Location ---------- PORT. PRESS. CYLINDER Above IAmbientlFRONT STORAGE - ICE HOUSE - Conc -1---------------------- Components --------------1- MCP --I List 100.0% ¡Acetylene High I 07/21/92 PAL~ TANK & CONST INC 015-0.-000427 ~2 - Fixed Containers on e Page 4 . . Hazmat Inventory Detail in Reference Number Order ---------~--------------------------------------------------------------------- 02-006 ~ETROLEUM DISTILLATE Liquid 1000 Moderate > Fire, Immed Hlth GAL ----------------------------------------------------------------------- CAS #: Trade Secret: No Form: Liquid Type: Mixture Days: 365 Use: FUEL ---- Daily Max GAL ----1-- Daily Average GAL --1-- Annual Amount GAL -- 1,000 500.00 3,000.00 ------ Storage -------1 Press I Temp -I--------~--- Location ---------- UNDER GROUND TANK \AmbientlAmbientlBACK SHOP - NEAR MECHANIC - Cone -1---------------------- Components --------------1- MCP --I List 100.0% Petroleum Distillate IModerate --------~~---------------------------------------------------------------------- 02-00TV COOKS PAINT Liquid 75 Moderate > Fire, Immed Hlth, Delay Hlth GAL ----------------------------------------------------------------------- CAS #: Trade Secret: No Form: Liquid Type: Mixture Days: 365 Use: PAINTING ---- Daily Max GAL ----1-- Daily Average GAL --1-- Annual Amount GAL -- 75 I 75.00 75.00 ------ Storage -------1 Press Temp -1------------ Location ---------- DRUM/BARREL-METALLIC IAmbientlAmbientlDESIGNATED "HAZ-MAT" FENCED & LO I I ¡AREA - Cone -1---------------------- Components 10.0% I 1,2-Propylene Glycol 30.0% \Xylene, Mixed 0.5% Ethylbenzene --------------1- MCP --I List ¡Low I \Moderate! IModeratel 07/21/92 PAL~ TANK & CONST INC 015-0.000427 ~02 - Fixed Containers on e Page 5 Hazmat Inventory Detail in Reference Number Order -------------------------------------------------------------------------------- 02-008 COOKS COATING EPOXY > Fire, Immed Hlth, Delay Hlth Liquid 70 Low GAL ----------------------------------------------------------------------- CAS #: Trade Secret: No Form: Liquid Type: Mixture Days: 30 Use: PAINTING ---- Daily Max GAL ----1-- Daily Average GAL --1-- Annual Amount GAL -- 70 55.00 I 70.00 ------ Storage -------1 Press 1 Temp -1------------ Location ---------- DRUM/BARREL-METALLIC IAmbient AmbientIDESIGNATED "HAZ-MAT" FENCED & LO I I IAREA - Cone -1---------------------- Components 10.0% Ethylene Glycol 15.0% ¡EPOXY RESINS 25.0% ITalc --------------1- MCP --¡List ILow I ¡Unrated 1 I Minimal 1 07/21/92 PAL~ TANK & CONST INC 015-0.000427 ~ 00 - Overall Site Page 6 <D> Notif./Evacuation/Medical -------------------------------------------------------------------------------- <1> Agency Notification ----------------------- IN CASE OF FIRE OR HEALTH HAZARDS, APPROPRIATE AGENCY WILL BE CALLED BY TELEPHONE, MOBILE PHONE OR RADIO TO BASE COMMUNICATION. <2> Employee Notif./Evacuation ------------------------------ PALMER TANK & CONSTRUCTION, INC IS FULLY EQUIPPED WITH A P.A. INTERCOM SYSTEM THROUGHOUT ENTIRE OPERATION. EVACUATION PROCEDURES ARE EMPLOYEES ARE TO MOVE IN A SAFE AND ORDERLY MANNER TO S MAIN GATE TO MAIN STREET AND ARE ADVISED TO CALL 911. <3> Public Notif./Evacuation ---------------------------- <4> Emergecny Medical Plan -------------------------- PALMER CONSTRUCTION, INC INJURED EMPLOYEES ARE FIRST TAKEN TO DR WILLARD CHRISTENSEN. EXTREME EMERGENCY ACCIDENTS, EMPLOYEES ARE TAKEN BY HALL'S AMBULANCE TO MEMORIAL HOSPITAL. MEMORIAL HOSPITAL 420 34TH STREET BAKERSFIELD, CA (805) 327-1792 07/21/92 PA~R TANK & CONST INC 015-0.000427 .., 00 - Overall Site Page 7 , <E> Prev./Minimization/Cleanup -------------------------------------------------------------------------------- <1> Release Prevention ---------------------- PREVENTION: USE OF GOGGLES, GLOVES AND DISPOSABLE COVERALLS. OXYGEN AND SCOTT AIR PACKS ALONG WITH MONITORS ARE ALWAYS AVAILABLE TO ALL EMPLOYEES AND ARE ON YARD LOCATION. ALL CANS OR CONTAINERS ARE TO BE SEALED AFTER USE AND PUT BACK IN "HAZARDOUS MATERIALS" FENCED OFF AND MARKED AREA. THIS AREA IS LOCKED AND/OR CLOSED AFTER AND DURING HOURS. <2> Release Containment ----------------------- PALMER TANK & CONSTRUCTION I INC EMPLOYEES ARE TO REPORT SPILLS (IF ANY) TO IMMEDIATE SUPERVISORS. MSDS SHEETS ARE POSTED IN GENERAL AREA OF WORKMEN AND CHEMICAL BEING USED. CONTACT "R.A.M. ENVIRONMENT" FOR ASSISTANCE, IF NEEDED. <3> Clean Up ------------ IN CASE OF SPILL, CLEAN UP AS DIRECTED AND DISPOSE OF AT HAZARDOUS WASTE SITE. PALMER TANK & CONSTRUCTION, INC HAS E.P.A NUMBER FOR DISþOSAL. SUCH CLEAN UP WILL BE PERFORMED OR ASSISTED BY "R.A.M. ENVIRONMENTAL". DISPOSAL WILL BE CONTRACTED THROUGH "LAIDLAW ENVIRONMENTAL". <4> Other Resource Activation ----------------------------- ~ 07/21/92 PAL~ TANK & CONST INC 015-0.000427 ,., 00 - Overall Site Page 8 ~ <F> Site Emergency Factors --------------------------------------------------------------------------------- <1> Special Hazards ------------------- <2> Utility Shut-Offs --------------------- A) GAS/PROPANE B) ELECTRICAL C) WATER D) SPECIAL E) LOCK BOX - S~ CRNR OF OFFICE BLDG #1. - SW SIDE OF OFFICE BLDG #1. BEHIND OPEN DOOR. - SW SIDE OF OFFICE BLDG #1. BEHIND BLDG. - MAIN CONTROL BOX IN OFFICE BLDG #1. ON OUTSIDE OF BLDG. - NO <3> Fire Protec./Avaîl. Water ----------------------------- FIRE EXTINGUISHERS ARE MOUNTED IN EVERY COMPANY VEHICLE. IN EVERY BLDG ON PREMISES REQUIRED BY STATE OR MAJOR OIL COMPANY. FIRE HYDRANT IS LOCATED ON S UNION AVENUE. ON E SIDE. APPROXIMATELY 1/2 WAY BETWEEN WHITE LANE AND PACHECO IN FRONT OF ROY PIERCE R.V. Ä. WE HAVE PRIVATE WATER WELL ON PREMISES. <4> Earthquake Vulnerability "---------------------------- ~ 07/21/92 PAL~ TANK & CONST INC 015-0.000427 ... 00 - Overall Site Page 9 , <G> Training' -------------------------------------------------------------------------------- <1> Training Record Location ---------------------------- OUR "INJURY AND ILLNESS PREVENTION PLAN" DOCUMENTATION AND MANUALS ARE KEPT IN MAIN OFFICE IN DESIGNATED BINDERS, MARKED ACCORDINGLY. ALSO "HAZARDOUS COMMUNICATION AND TRAINING" MANUALS ARE ALSO ON SITE. ORIGINALS TAKEN BY D.A. 'S OFFICE. REQUEST FOR THEM HAS BEEN MADE. AS OF THIS DATE. THEY HAVE NOT BEEN RETURNED. ALL EMPLOYEES ARE ALSO TRAINED IN "C.P.R. AND FIRST AID". PULMONARY FUNCTION TESTS ARE ALSO CONDUCTED. DRUG TESTING BEFORE HIRE. RANDOM THROUGHOUT EMPLOYMENT AND ALWAYS IF AN INJURT OCCURS. ENTIRE CREW IS TESTED FOR DRUGS. <2> Describe Training Program ----------------------------- <3> Emer. Agency Coordination ----------------------------- <4> Emer. Response Equipment ----------------------------