HomeMy WebLinkAboutMITIGATION (2)
i~ 07/21/92
PAL~ TANK & CONST INC 015-0~000427
~ Overall Site with 1 ~
~,5J,g e
1
~ General Information
1==============================================================================1
I I---------------~------------------------------------------------------------1 I
1 I Location: 2464 S UNION AV Map: 124 Hazard: Unrated II
IICommunity: "BFD" RESPONSE AREA" Grid: 17C 1 AOV: 0.011
I 1----------------------------------------------------------------------------1 I
11--- Contact Name ---1------ Title ------1-- Business Phone --I 24-Hour Phone 1 I
IIJERRY W PALMER IPRESIDENT 1(805) 834-1110 x 1(805) 834-316911
II I . I() x I() II
I 1--------------------1-------------------1--------------------1--------------1 I
11--------------------------- Administrative Data ----------------------------1 I
I I Mail Addrs: 2464 S UNION AV D&B Number: I I
II City: BAKERSFIELD State: CA Zip: 93307- II
1 I Comm Code: 015-901 "BFD" RESPONSE AREA" SIC Code: I I
I I -------------------------------------------------------------------------- 1 I
II Owner: JERRY W PALMER Phone: (805) 834-1110 II
I I Address: 2470 S UNION AV State: CA I I
II City: BAKERSFIELD Zip: 93307- II
I 1----------------------------------------------------------------------------1 I
I I Summary -------------------------------------------------------------------11
II II
I I ABOVEGROUND OILFIELD TANK CONSTRUCTION YARD, WITH A MECHANICS SHOP AT THE I I
1 IE END OF PROPERTY. AN ABOVEGROUND DIESEL TANK IS LOCATED IN THE SE CRNR I I
IIOF YARD. II
" II
II II
I 1----------------------------------------------------------------------------11
1==============================================================================1
tOZJ~ ?
~
07/21/92
, PALUIiR TANK & CONST INC 015-01.i¡¡000427
Hazmat ~entory List in Reference"'mber Order
Page
2
,ó
02 - Fixed Containers on Site
Pln-Ref Name/Hazards
Form
Quantity
MCP
--------------------------------------------------------------------------------
02-001 POLYLITE POLYESTER RESIN
> Fire. Immed Hlth. Delay Hlth
Liquid
55 Moderate
GAL
--------------------------------------------------------------------------------
02-002 OXYGEN
> Fire. Pressure
Gas
1000 Low
FT3.
.--------------------------------------------------------------------------------
02-004 ACETYLENE Gas
> Fire. Pressure. Immed Hlth, Delay Hlth
20000 High
FT3
--------------------------------------------------------------------------------
02-006 PETROLEUM DISTILLATE
> Fire, Immed Hlth
Liquid
1000 Moderate
GAL
.--------------------------------------------------------------------------------
02-007 COOKS PAINT
> Fire, Immed Hlth, Delay Hlth
Liquid
75 Moderate
GAL
---------------------------------------------------------------------------------
02-008 COOKS COATING EPOXY
> Fire. Immed Hlth. Delay Hlth
Liquid
70 Low
GAL
.--------------------------------------------------------------------------------
.~-------------------------------------------------------------------------------
07/21/92
PA~ TANK & CONST INC 015-0~000427
~2 - Fixed Containers on ~e
Page
3
,;I'
~' Hazmat Inventory Detail in Reference Number Order
--------- ----------------------------------------------------------------------
02-001 POLYLITE POLYESTER RESIN Liquid 55 Moderate
> Fire, Immed Hlth, Delay Hlth GAL
-----------------------------------------------------------------------
CAS :It: 100425
Trade Secret: No
Form: Liquid
Type: Mixture Days: 60 Use: FABRICATION
.---- Daily Max GAL ----1-- Daily Average GAL --1-- Annual Amount GAL --
55 I 35.00 . 110.00
------ Storage -------1 Press 1 Temp -1------------ Location ----------
DRUM/BARREL-METALLIC AmbientAmbientDESIGNATED "HAZ-MAT" FENCED & LO
I I ¡AREA
- Conc -1---------------------- Components --------------1- MCP --¡List
45.0% ¡Styrene IModeratej
0.1% ¡N,N-Dimethylaniline Moderate
..- ~ ;=~ ~;~i~~~~~ --- - -- -.---------- --- - - - -- - --- - --- ---~:~ -------- - - - ~~ ~~- -~~: -- - ---
> Fire, Pressure FT3
-----------------------------------------------------------------------
CAS #: 7782449
Trade Secret: No
Form: Gas
Type: Pure
Days: 365 Use: FABRICATION
..---- Daily Max FT3 ----1-- Daily Average FT3 --1-- Annual Amount FT3 --
1,000 I 1,000.00 24,000.00
------ Storage -------1 Press Temp -1------------ Location ----------
PORT. PRESS. CYLINDER IAmbientlAmbientlFRONT BLDG CENTER - FREE STANDIN
- Conc -1---------------------- Components ----------~---!- MCP --¡List
100.0% Oxygen , Compressed Low
_.._-----~~-----------------------------------------------------------------~---
02-004 ACETYLENE Gas 20000 High
> Fire, Pressure, Immed Hlth, Delay Hlth FT3
-----------------------------------------------------------------------
CAS :It: 74862
Trade Secret: No
Form: Gas
Type: Pure
Days: 365 Use: WELDING SOLDERING
Daily Max FT3 ----1-- Daily Average FT3 --1-- Annual Amount FT3 --
20,000 I 20,000.00 ¡ 200,000.00
------ Storage -------1 Press I Temp -1------------ Location ----------
PORT. PRESS. CYLINDER Above IAmbientlFRONT STORAGE - ICE HOUSE
- Conc -1---------------------- Components --------------1- MCP --I List
100.0% ¡Acetylene High I
07/21/92
PAL~ TANK & CONST INC 015-0.-000427
~2 - Fixed Containers on e
Page
4
.
. Hazmat Inventory Detail in Reference Number Order
---------~---------------------------------------------------------------------
02-006 ~ETROLEUM DISTILLATE Liquid 1000 Moderate
> Fire, Immed Hlth GAL
-----------------------------------------------------------------------
CAS #:
Trade Secret: No
Form: Liquid
Type: Mixture Days: 365 Use: FUEL
---- Daily Max GAL ----1-- Daily Average GAL --1-- Annual Amount GAL --
1,000 500.00 3,000.00
------ Storage -------1 Press I Temp -I--------~--- Location ----------
UNDER GROUND TANK \AmbientlAmbientlBACK SHOP - NEAR MECHANIC
- Cone -1---------------------- Components --------------1- MCP --I List
100.0% Petroleum Distillate IModerate
--------~~----------------------------------------------------------------------
02-00TV COOKS PAINT Liquid 75 Moderate
> Fire, Immed Hlth, Delay Hlth GAL
-----------------------------------------------------------------------
CAS #:
Trade Secret: No
Form: Liquid
Type: Mixture Days: 365 Use: PAINTING
---- Daily Max GAL ----1-- Daily Average GAL --1-- Annual Amount GAL --
75 I 75.00 75.00
------ Storage -------1 Press Temp -1------------ Location ----------
DRUM/BARREL-METALLIC IAmbientlAmbientlDESIGNATED "HAZ-MAT" FENCED & LO
I I ¡AREA
- Cone -1---------------------- Components
10.0% I 1,2-Propylene Glycol
30.0% \Xylene, Mixed
0.5% Ethylbenzene
--------------1- MCP --I List
¡Low I
\Moderate!
IModeratel
07/21/92
PAL~ TANK & CONST INC 015-0.000427
~02 - Fixed Containers on e
Page
5
Hazmat Inventory Detail in Reference Number Order
--------------------------------------------------------------------------------
02-008 COOKS COATING EPOXY
> Fire, Immed Hlth, Delay Hlth
Liquid
70 Low
GAL
-----------------------------------------------------------------------
CAS #:
Trade Secret: No
Form: Liquid
Type: Mixture Days: 30 Use: PAINTING
---- Daily Max GAL ----1-- Daily Average GAL --1-- Annual Amount GAL --
70 55.00 I 70.00
------ Storage -------1 Press 1 Temp -1------------ Location ----------
DRUM/BARREL-METALLIC IAmbientAmbientIDESIGNATED "HAZ-MAT" FENCED & LO
I I IAREA
- Cone -1---------------------- Components
10.0% Ethylene Glycol
15.0% ¡EPOXY RESINS
25.0% ITalc
--------------1- MCP --¡List
ILow I
¡Unrated 1
I Minimal 1
07/21/92
PAL~ TANK & CONST INC 015-0.000427
~ 00 - Overall Site
Page
6
<D> Notif./Evacuation/Medical
--------------------------------------------------------------------------------
<1> Agency Notification
-----------------------
IN CASE OF FIRE OR HEALTH HAZARDS, APPROPRIATE AGENCY WILL BE CALLED BY
TELEPHONE, MOBILE PHONE OR RADIO TO BASE COMMUNICATION.
<2> Employee Notif./Evacuation
------------------------------
PALMER TANK & CONSTRUCTION, INC IS FULLY EQUIPPED WITH A P.A. INTERCOM
SYSTEM THROUGHOUT ENTIRE OPERATION. EVACUATION PROCEDURES ARE
EMPLOYEES ARE TO MOVE IN A SAFE AND ORDERLY MANNER TO S MAIN GATE TO
MAIN STREET AND ARE ADVISED TO CALL 911.
<3> Public Notif./Evacuation
----------------------------
<4> Emergecny Medical Plan
--------------------------
PALMER CONSTRUCTION, INC INJURED EMPLOYEES ARE FIRST TAKEN TO
DR WILLARD CHRISTENSEN. EXTREME EMERGENCY ACCIDENTS, EMPLOYEES
ARE TAKEN BY HALL'S AMBULANCE TO MEMORIAL HOSPITAL.
MEMORIAL HOSPITAL
420 34TH STREET
BAKERSFIELD, CA
(805) 327-1792
07/21/92
PA~R TANK & CONST INC 015-0.000427
.., 00 - Overall Site
Page
7
,
<E> Prev./Minimization/Cleanup
--------------------------------------------------------------------------------
<1> Release Prevention
----------------------
PREVENTION: USE OF GOGGLES, GLOVES AND DISPOSABLE COVERALLS.
OXYGEN AND SCOTT AIR PACKS ALONG WITH MONITORS ARE ALWAYS AVAILABLE
TO ALL EMPLOYEES AND ARE ON YARD LOCATION.
ALL CANS OR CONTAINERS ARE TO BE SEALED AFTER USE AND PUT BACK IN
"HAZARDOUS MATERIALS" FENCED OFF AND MARKED AREA. THIS AREA IS LOCKED
AND/OR CLOSED AFTER AND DURING HOURS.
<2> Release Containment
-----------------------
PALMER TANK & CONSTRUCTION I INC EMPLOYEES ARE TO REPORT SPILLS (IF ANY)
TO IMMEDIATE SUPERVISORS. MSDS SHEETS ARE POSTED IN GENERAL AREA OF
WORKMEN AND CHEMICAL BEING USED.
CONTACT "R.A.M. ENVIRONMENT" FOR ASSISTANCE, IF NEEDED.
<3> Clean Up
------------
IN CASE OF SPILL, CLEAN UP AS DIRECTED AND DISPOSE OF AT HAZARDOUS WASTE
SITE. PALMER TANK & CONSTRUCTION, INC HAS E.P.A NUMBER FOR DISþOSAL.
SUCH CLEAN UP WILL BE PERFORMED OR ASSISTED BY "R.A.M. ENVIRONMENTAL".
DISPOSAL WILL BE CONTRACTED THROUGH "LAIDLAW ENVIRONMENTAL".
<4> Other Resource Activation
-----------------------------
~ 07/21/92
PAL~ TANK & CONST INC 015-0.000427
,., 00 - Overall Site
Page
8
~
<F> Site Emergency Factors
---------------------------------------------------------------------------------
<1> Special Hazards
-------------------
<2> Utility Shut-Offs
---------------------
A) GAS/PROPANE
B) ELECTRICAL
C) WATER
D) SPECIAL
E) LOCK BOX
- S~ CRNR OF OFFICE BLDG #1.
- SW SIDE OF OFFICE BLDG #1. BEHIND OPEN DOOR.
- SW SIDE OF OFFICE BLDG #1. BEHIND BLDG.
- MAIN CONTROL BOX IN OFFICE BLDG #1. ON OUTSIDE OF BLDG.
- NO
<3> Fire Protec./Avaîl. Water
-----------------------------
FIRE EXTINGUISHERS ARE MOUNTED IN EVERY COMPANY VEHICLE. IN EVERY
BLDG ON PREMISES REQUIRED BY STATE OR MAJOR OIL COMPANY. FIRE HYDRANT
IS LOCATED ON S UNION AVENUE. ON E SIDE. APPROXIMATELY 1/2 WAY BETWEEN
WHITE LANE AND PACHECO IN FRONT OF ROY PIERCE R.V.
Ä. WE HAVE PRIVATE WATER WELL ON PREMISES.
<4> Earthquake Vulnerability
"----------------------------
~ 07/21/92
PAL~ TANK & CONST INC 015-0.000427
... 00 - Overall Site
Page
9
,
<G> Training'
--------------------------------------------------------------------------------
<1> Training Record Location
----------------------------
OUR "INJURY AND ILLNESS PREVENTION PLAN" DOCUMENTATION AND MANUALS ARE KEPT
IN MAIN OFFICE IN DESIGNATED BINDERS, MARKED ACCORDINGLY.
ALSO "HAZARDOUS COMMUNICATION AND TRAINING" MANUALS ARE ALSO ON SITE.
ORIGINALS TAKEN BY D.A. 'S OFFICE. REQUEST FOR THEM HAS BEEN MADE. AS OF
THIS DATE. THEY HAVE NOT BEEN RETURNED.
ALL EMPLOYEES ARE ALSO TRAINED IN "C.P.R. AND FIRST AID". PULMONARY
FUNCTION TESTS ARE ALSO CONDUCTED. DRUG TESTING BEFORE HIRE. RANDOM
THROUGHOUT EMPLOYMENT AND ALWAYS IF AN INJURT OCCURS. ENTIRE CREW IS TESTED
FOR DRUGS.
<2> Describe Training Program
-----------------------------
<3> Emer. Agency Coordination
-----------------------------
<4> Emer. Response Equipment
----------------------------