Loading...
HomeMy WebLinkAboutABOVEGROUND TANK 12/23/1998 e e NOTE TO FILE BAKERSFIELD MUNICIPAL AIRPORT 2000 South Union Avenue Bakersfield, CA Final on Wednesday, March 3, 1999. Recommended 2A40 BC Fire Extinguisher mounted on light pole. Card reader was not operational. All signs, and function test O.K. Allowed them to open. Steve Underwood Inspector .;~ fÞ '.... -- - /' CITY OF BAKERSFIELD OFFICE OF ENVIRONMENTAL SERVICES 1715 Chester Ave., Bakersfield, CA (80Sr!2~-3979 Ll!.i..~Cì>= ¡J.i"ir Dtc ~.I¿ VF5;¡j 8yo 231998 APPLICATION TO INSTALL AND/OR REMOVEo~ ABOVE GROUND STORAGE TANK(S) In confonnity with provisions of pertinent ordinances, codes and/or regulations, permission is hereby granted to: CITY OF BAKERSFIELD Name of Company 1501 TRUXTUN AVENUE, BAKERSFIELD CA 93301 Address to display, store, install, use, operate, sell or handle materials or process involving or creating conditions deemed hazardous to life or property as follows: 12,000 GALLON ABOVE-GROUND FUEL STORAGE TANK AND DISPENSING SYSTEM FOR 100 LL AVIATION FUEL TO BE LOCATED AT THE BAKERSFIELD MUNICIPAL AIRPORT. 2000 SOUTH UNION AVENUE. subject to the provisions and/or limitations as provided. Violation of pertinent ordinances, codes' and/or regulations shall void this permit. ~ed ..) Pennit Denied / - ,,29 n Date =\Ž'~ 'BRAD"B. UNDERWOOD . Applicant Name (print) ~~ ~l;l~ Applicant Signature TillS APPLICATION BECOMES A PERMIT WHEN APPROVED '" ," -;7;:¡ --.---------------- .----.---------.--------------- --- , . - , ~ e RECEIVED JAN 1 4 1999 EICA TION e ABOVEGROUND FUELSTORAGETANKSP A. Tanks: I, The fuel tank to be installed at the Bakersfield Municipal Airport shall have a total capacity of 12,000 gallons. 2. Steel tank openings shall be threaded except for detector tube. 3, The protected above-ground tank shall be furnished as a complete, factory prefabricated unit, meeting UL-2085 requirements and the Uniform Fire Code (UFC) Standard A-Il-F 1, latest edition, 4, Primary containment of not less than 3/16 inch steel capable of on-site pressure testing for verification of primary tank integrity, An external protective shell shall be 10 gage steel. s. Insulation shall be 3 inch to 6 inch thick monolithic lightweight concrete or equal, meeting the requirements ofUL-2085. 6. The secondary containment must have the capability of physical monitoring for leaks from the primary containment, field pressure testable and containing a means to remove liquid. Secondary containment may be inside or outside of the thermal/physical protective material as submitted, tested and certified by UFC 79-7 for the tank manufacturer. 7, ' The exterior surface of the tank assembly shall be painted with one coat epoxy primer and two coats of petroleum resistant epoxy coating. Color to be white. 8, The interior surface of the tank assembly shan be painted with two coats mil spec M4556E epoxy coating for aviation fueling. 9, The entire tank assembly, including primary and secondary containment and thermal/physical protective material, shall be warranted by the manufacturer for 30 years, 10. Primary containment shall be equipped with atmospheric and emergency vents. II , All openings to primary and secondary containment shall be on top. 12, Tank assembly shall be equipped with Zone 4 seismic anchorage brackets, factory tàbricated, which shall be attached to the concrete base slab and shall accept the tank support to prevent horizontal movement. 13, When used for storage and dispensing of gasoline, tank shall be tested and equipped with required fittings to meet CARB requirements, 14. Contents shall be identified and tank shall be labeled as required by the City Fire Department. 15, Tanks requiring vapor recovery shall be equipped with two-point delivery systems. B, Fill lines: -I, _ Tank shall have low fill connection point with secondary containment. 2, Fill lines on tank shall be equipped with overfill shut-otfvalves. Valves shall be designed to be operated on above-ground tanks, provide a positive shut-off and be set at ninety percent (90%) of tank capacity, Airport fucllank spec,. page 1 of) ," ,. , _.;.~ t " e e C. Piping: ), All product piping shall be schedule 40 galvanized steel. 2. All exposed piping and electrical conduit shall be primed and painted with finish coat matching color of above ground storage tank. D. Dispensers: I . The fuel tank shall be equipped with one submersible pump with floating suction and one dispenser located at one end of the tank as approved by the General Services Superintendent. The dispensers shall have a maximum flow rate of22 gpm, 2, Shear valves must be installed on lines under each pump, The dispensers shall meet all applicable codes, 3, Fueling nozzle shall be 1" aviation overwing, 4, Hose reel shall be spring be spring rewind with)" x 50' aviation hose. 5, Static grounding reel shall be spring rewind with 50' plastic coated, non-kinking cable. E. Card Reader I Control Unit: I , The fuel tank system shall be equipped with one card reader / control unit, located at one end of the tank, as approved by the General Services Superintendent. 2, System shall be configured to control a minimum of two dispensers. 3, System shall be capable of accepting a multiple number of credit cards (i.e. MasterCard, Visa, American Express, Discover, Oil Companies and Private cards for local accounts), 4, The card reader I control unit shall be Applied Technology Model 1000 or equal. F. Electrical: I , All electrical shall conform with NEC latest edition Group 11, Class 1. 2, Manufacturer shall provide all required electrical requirements and diagrams to the City, Electrical service to the concrete pad shall be done by City. 3, Emergency disconnect shall be installed approximately 25 feet from the tank by City. G, Telephone: 1, If required for the card reader / control unit, telephone service shall be supplied to the concrete pad by others. H, Concrete Pad: . ) , City shall construct concrete pad for tank prior to delivery. 2, Manufacturer shall provide City with seismic calculations and concrete pad requirements, including: dimensions; concrete strength; rebar size and layout; bolt size, type and location; conduit for electrical/telephone size, type and location. Airport fllcltank spec,. page 2 of] .~ ~ ,~.;.~/(' '4 e e I, Permits: 1 , City of Bakersfield shall obtain the necessary permits from the City Fire Department and Building Department. 2, Manufacturer/supplier shall obtain permit from the San Joaquin Valley Unified Air Pollution Control District and others as required, except those listed above. J, Testing: 3, Before tank is fueled, an air test must be performed per manufacturers specifications. 4, Under no circumstances should test pressure on primary or secondary tank areas exceed 5 PSI. Test must be witnessed by regulatory agency and by owner's representative, 5. San Joaquin Valley Unified Air Pollution Control District (SJVUAPCD) testing will be per requirements of Authority to Construct (A TC) issued by the Air District, 6, All test result documentation to be submitted to owner or their representative prior to final acceptance 'of tank assembly. 7. All pumping units shall be tested, calibrated and sealed by qualified individual. If required by owner and/or regulating agency, Weights and Measures shall be notified, 8. Manufacturer shall provide onsite startup assistance for tank, pumping system and card reader / control unit. K. Manufacturers: I. The fuel tanks shall be 1 st Fueling Systems, Enviro- Vault, Convault, or approved equal. The manufacturer listed is to provide function and minimum quality and is not intended to be exclusive, Other manufacturer's making products meeting the requirements, of equal or better quality, may be substituted in accordance with the specifications, L. Shipping: I. Tank and dispensing system shall be shipped FOB to the Bakersfield Municipal Airport and set on the concrete pad by the manufacturer/supplier. M, Quoted Price: 1, Quoted price shall be for one 12,000 gallon above ground tank and dispensing unit per these specifications, Freight/shipping, placement on concrete pad and obtaining required permit(s) shall be included in the quoted price. Airport ruel tank spec,. page J or J /~~ e {I Å j ::J r \ , 1st \ \~ng Systems Main Office· Kansas City 10800 Farley, Suite 265 Overland Park. KS 66210 Tel (888) 417-8383 Fax (913) 345-1920 _viation Refuelers and A viation Fuel Farms" Baltimore Office Martin State Airport 701 Wilson Point Road, Box 21 Baltimore, MD 21220 Tel (410) 686-3574 Fax (410) 686-3575 Visit us at www.1stfueling.com 12000 Gallon Ul2085 Fire Rated Tank With 22 Gpm In-to-plane Pumping System For A vgas Fuel Model # 12-FG-A-022-I System Operations System is designed to be loaded from transport truck into storage. The system also enables direct in-to-plane fueling via overwing hose reel assembly. * Lease- To-Own * Guaranteed Approval * No-Money Down! ') e e :...l i' Model # 12-FG-A-022-I Fire Rated VI 2085 Fuel Storage Tank Tank · Construction · Porch & · Rainshield · Fire Guard, Fire rated construction certified to UL 142 & 2085 specifications Meets UFC & NFPA 30 codes, (2) hour bum, bullistics, & vehicle impact rated Porch (5'x8') with rainshiield under pumping module Liquid tight, 3" lip and drain valve for secondary containment (74.8) gallons Paint & Finish · Surface prepared with with high solids epoxy primer · Finished with two (2) coats of polyurethane Fire Rated Tank Overfill Prot(!ction, Venting, & Piping Tank . Overfill valve, 2" for two openings, Vaporless Mfg Inc model OFP-2-2, (1 Each) Piping . Clock gauge with alarm, Morrison model 918-0100, (1 Each) · Vent, emergency, 8"FPT, 8oz, cast iron, O-ring seal, Morrison model 24401-0600A V, (2 Each) · Pressure Vacuum working vent CARB Approved, Morrison model 749CRB, (1 Each) · Interstitial leak detection gauge, Krueger Sentry Gauge Company, Inc. model K2-96, (l Each) Inlet Piping Fill Piping . Valve, butterfly, 3", 150 Ib.,SS disc with Buna-N seat, I. H. D. model 6220-01-3, (2 Each) · Check valve, 3" flanged, Morrison model 246DRFOI00, (1 Each) · Vapor recovery adapter, 3", Morrison model 323-0100, (1 Each) · Vapor recovery adapter cap, Morrison model 323C-0100, (1 Each) · Adapter, 3MCAM X 3 150#, AL, PT Coupling model PF30AAL, (1 Each) · Dust cap, 3CAM, AL, PT Coupling model 30V AL, (1 Each) 22 Gpm Avgas Dispensing System Pump & Motor . Pump Dispenser, w/ 100: 1 pulser and 1" solenoid, white lower doors, lighted ad panel, ad panel-A V GAS, I" suction slow down valve, Gasboy model 9153AHC~CC-PP, (1 Each) Meter Filtration . Filter/monitor, rated to 48 gpm, meets IP specifications, with differential pressure gauge, includes new fuse, Facet model VFG-22-612-PG, (1 Each) Hose Reel . Hose reel with spring rewind for I "x50' hose, Hannay model N818-25-26-BTR, (1 Each) · Avgas I" overwing nozzle with I" swivel, OPW model 295SA-0135, (1 Each) · Reel, static grounding, spring rewind with 50' plastic coated cable, Hannay model HGR-50-50, (1 Each) · 1" X 50' aviation hose, coupled male x male" Goodall Rubber Company model IX50, (1 Each) General . Solenoid Valve, 2" Snap Tite viton, Morrison model 710-0200, (1 Each) · Valve, butterfly, 2",150 lb., SS disc with Buna-N seat, I. H. D. model 6220-01-2, (1 Each) · Emergency Shutoff Valve, 2" XI 1/2" with union, Morrison model 636U-OlOO, (1 Each) · FillRite hand pump, FillRite model 152, (1 Each) e e DATE: January 29, 1999 TO: STEVE UNDERWOOD, FIRE INSPECTOR FROM: BRAD B. UNDERWOOD, GENERAL SERVICES SUPERINTENDENT SUBJECT: BAKERSFIELD MUNICIPAL AIRPORT ABOVE GROUND FUEL FACILITY After installation of the 12,000 gallon above ground fuel facility and prior to operation, City employees will install guard posts per Uniform Fire Code Section 8001.9.3