Loading...
HomeMy WebLinkAboutBUSINESS PLAN 9/29/2004 ~ <' BEACON TRUCKS TOP #3074 Manager : Location: 3225 BUCK OWENS BLVD City BAKERSFIELD CommCode: COUNTY STATION 66 EPA Numb: Emergency Contact / Title JOEL PEREZ / MANAGER Business Phone: (661) 324-9481x 24-Hour Phone : (661) 587-1669x Pager Phone : ( ) - x Hazmat Hazards: Contact : SANDY HUFF MailAddr: 685 W 3RD ST City : HANFORD Owner Address : City VALERO ENERGY CORPORATION 685 W 3RD ST : HANFORD Period : Preparer: Certif'd: ParcelNo: to ~mergency Directives: '11 p~~ ¡J~"1UL BusPhone: Map : 102 Grid: 23D SiteID: 015-021-000690 (661) 324-9481 CommHaz : Low FacUnits: 1 AOV: SIC Code:5541 DunnBrad:00-917-4921 Emergency Contact JIM RUCH Business Phone: 24-Hour Phone : Pager Phone : Fire Press / Title / AREA MANAGER (559) 583 -3285x (559) 582-4778x (559) 583-4472x ImmHlth DelHlth Phone: (559) 583-3298x State: CA Zip : 93232 Phone: (559) 583-3298x '\ State: CA Zip : 93232 ,\ .{ TotalASTs: = Gæl TotalUSTs: = Gal RSs: No 1- J-q - ()t{ -1- :3 09/28/2004 " F BEACON TRUCKS TOP #3074 SiteID: 015-021-000690 9 ) STORAGE CONTAINER DATA UST FORM A Last Action Type: FACILITY/SITE INFORMATION Business Name: BEACON TRUCKSTOP #3074 Cross Street : Business Type: Org Type: Total Tanks : 3 IndnRes/Trust: No PA Contact: PROPERTY OWNER INFORMATION Name : JIM RUCH Phone: (559) 583-3285x Address: City : State: Zip: Type : TANK OWNER INFORMATION Name : JIM RUCH Phone: (559) 583-3285x Address: City : State: Zip: Type : BOE UST Fee# : 24660 Financ'l Resp: SELF INSURED Legal Notif : Tank Owner Mailing Address Date:04/06/2000 Phone: (559) 582-0241x Name:SANDY HILL Ttl:OPERATIONS/ENVIRON. SPECIALIST State UST # : 1998 Upg Cert#: 00719 -2 - 09/28/2004 ... F BEACON TRUCKS TOP #3074 f= Hazmat Inventory f== MCP+DailyMax Order SiteID: 015-021-000690 ì By Facility Unit ì Fixed Containers on Site ì specHazlEPA Hazards Frm I DailyMax unitlMCP F IH DH L 14000.00 GAL Mod F IH DH L 10000.00 GAL Mod F IH DH L 20000.00 GAL Low F P IH G 876.00 FT3 Min Hazmat Common Name... UNLEADED PREMIUM UNLEADED DIESEL FUEL #1 CARBON DIOXIDE -3- 09/28/2004 F BEACON TRUCKSTOP #3074 f= Inventory Item 0006 = COMMON NAME / CHEMICAL NAME UNLEADED SiteID: 015-021-000690 ì Facility Unit: Fixed Containers on Site ì Days On Site 365 Location within this Facility Unit Map: Grid: CAS# 8006-61-9 STATE - TYPE Liquid Pure PRESSURE Ambient TEMPERATURE Ambient CONTAINER TYPE UNDER GROUND TANK Largest Container 14000.00 GAL AMOUNTS AT THIS LOCATION Daily Maximum 14000.00 GAL Daily Average 10500.00 GAL %Wt. I 100.00· Gasoline HAZARDOUS COMPONENTS ~ CAS# I 8006619 TSecret RS BioHaz Radioactive/Amount EPA Hazards NFPA USDOT# MCP No No No No/ Curies F IH DH / / / Mod HAZARD ASSESSMENTS Ag.Defined1: MISC. LOCAL AGENCY DATA Ag.Defined2: Ag.Defined3: Ag.Defined4: Ag.Defined5: Ag.Defined6: Ag.Defined7: Ag.Defined9: Ag.Define10: Ag.Defined8: - Ag.Define11 -4- 09/28/2004 , F BEACON TRUCKS TOP #3074 SiteID: 015-021-000690 ì f= Inventory Item 0006 Facility Unit: Fixed Containers on Site ì STORAGE CONTAINER DATA (UST FORM B and AGENCY-DEFINED) Page 1 of 2 Last Action Type: Location In Site: TANK DESCRIPTION Tank ID#: 3 Mfr: Trusco Installed: 3/1997 Capacity: 14000 Gals Additional Info: Compart Tank: N No. Of Comparts: Tank Use: MOTOR VEHICLE FUEL MatI Name:UNLEADED TANK CONTENTS Petrol Type: REGULAR UNLEADED Cas #: 8006-61-9 TANK CONSTRUCTION Type : DOUBLE WALL Material(p): STEEL CLAD W/FIBERGLASS R. P. Material(s): STEEL CLAD W/FIBERGLASS R. P. Lining : UNLINED Corr Prot: FIBERGLASS REINFORCED Spill Cnt : 1997 Drop Tube : 1997 Striker Plate: 1997 Sgl Wall: PLASTIC Alarm : ·Ball Float : Fill Tube S/O: 1997 TANK LEAK DETECTION Dbl Wall: AUTOMATIC TANK GAUGING Installed: Installed: Exempt: No INTERSTITIAL MONITORING Last Used: TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE Qty Remaining: Was Filled: No -5- 09/28/2004 F BEACON TRUCKSTOP #3074 SiteID: 015-021-000690 ì f= Inventory Item 0006 Facility Unit: Fixed Containers on Site ì STORAGE CONTAINER DATA (UST FORM B and AGENCY-DEFINED) Page 2 of 2 PIPING CONSTRUCTION Piping T~e : Const: Mfgr : Mtl : & : Corr : Prot : UnderGround PRESSURE DOUBLE WALL Smith FIBERGLASS AboveGround Piping FIBERGLASS FIBERGLASS PIPING LEAK DETECTION UnderGround Piping AboveGround Piping AUTOMATIC LEAK DETECTORS Installed: 09/03/1997 Date: 04/06/2000 Name:Sandy Hill Prmt Number: 0690 DISPENSER CONTAINMENT T~e: FLOAT MECH. SHUTS OFF SHEAR VAL. OWNER/OPERATOR SIGNATURE Ttl:Operations & environmental Spec. Approved: Yes Expiration Date: 06/30/2006 AGENCY DEFINED TANK/LINE TEST : CP CERT. : MANWAY INSP. : UST MaNIT. CERT:07/13/2004 STORAGE CONTAINER DATA (UST FORM C) Installer Certified by tank/piping manufacturer: Yes Installation Inspected & Certified by Registered Engineer: Yes Installation Inspected by Unified Program Agency: Yes Manufacturer's Checklist Completed: Yes Installer Certified by Contractors' State License Board: Yes Approved Alternate methods: Date: 04/06/2000 Name:Sandy Hill Ttl:Operations & environmental Spec. -6- 09/28/2004 F BEACON TRUCKSTOP #3074 p= Inventory Item 0005 === COMMON NAME / CHEMICAL NAME PREMIUM UNLEADED SiteID: 015-021-000690 9 Facility Unit: Fixed Containers on Site 9 Days On Site 365 Location within this Facility Unit Map: Grid: CAS# 8006-61-9 STATE - TYPE Liquid Pure PRESSURE Ambient TEMPERATURE Ambient CONTAINER TYPE UNDER GROUND TANK Largest Container 10000.00 GAL AMOUNTS AT THIS LOCATION Daily Maximum 10000.00 GAL Daily Average 7500.00 GAL %wt. I 100.00 Gasoline HAZARDOUS COMPONENTS ~ No CAS # I 8006619 TSecret RS BioHaz Radioactive/Amount EPA Hazards NFPA USDOT# MCP No No No No/ Curies F IH DH / / / Mod HAZARD ASSESSMENTS Ag.Defined1: MISC. LOCAL AGENCY DATA Ag.Defined2: Ag.Defined3: Ag.Defined4: Ag.Defined5: Ag.Defined6: Ag.Defined7: Ag.Defined9: Ag.Define10: Ag.Defined8: - Ag.Define11 -7- 09/28/2004 , F BEACON TRUCKSTOP #3074 SiteID: 015-021-000690 9 p= Inventory Item 0005 Facility Unit: Fixed Containers on Site 9 STORAGE CONTAINER DATA (UST FORM B and AGENCY-DEFINED) Page 1 of 2 Last Action Type: Location In Site: TANK DESCRIPTION Tank ID#: 2 Mfr: Trusco Installed: 3/1997 Capacity: 10000 Gals Additional Info: Compart Tank: N No. Of Comparts: Tank Use: MOTOR VEHICLE FUEL MatI Name:PREMIUM UNLEADED TANK CONTENTS Petrol Type: PREMIUM UNLEADED Cas #: 8006-61-9 TANK CONSTRUCTION Type : DOUBLE WALL Material(p): STEEL CLAD W/FIBERGLASS R. P. Material(s): STEEL CLAD W/FIBERGLASS R. P. Lining : UNLINED Corr Prot: FIBERGLASS REINFORCED Spill Cnt : 1997 Drop Tube : 1997 Striker Plate: 1997 Sgl Wall: PLASTIC Alarm : Ball Float : Fill Tube S/O: 1997 TANK LEAK DETECTION Dbl Wall: AUTOMATIC Installed: Installed: Exempt: No TANK GAUGING INTERSTITIAL MONITORING Last Used: TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE Qty Remaining: Was Filled: No -8- 09/28/2004 F BEACON TRUCKSTOP #3074 SiteID: 015-021-000690 ì f= Inventory Item 0005 Facility Unit: Fixed Containers on Site ì STORAGE CONTAINER DATA (UST FORM B and AGENCY-DEFINED) Page 2 of 2 PIPING CONSTRUCTION Piping Type: Const: Mfgr : Mtl : & : Corr : Prot : UnderGround PRESSURE DOUBLE WALL Smith FIBERGLASS AboveGround Piping FIBERGLASS FIBERGLASS PIPING LEAK DETECTION UnderGround Piping AboveGround Piping AUTOMATIC LEAK DETECTORS Installed: 09/03/1997 Date: 04/06/2000 Name:Sandy Hill Prmt Number: 0690 DISPENSER CONTAINMENT Type: FLOAT MECH. SHUTS OFF SHEAR VAL. OWNER/OPERATOR SIGNATURE Ttl:Operations & Environmental Spec. Approved: Yes Expiration Date: 06/30/2006 AGENCY DEFINED TANK/LINE TEST : CP CERT. : MANWAY INSP. : UST MONIT. CERT:07/13/2004 STORAGE CONTAINER DATA (UST FORM C) Installer Certified by tank/piping manufacturer: Yes Installation Inspected & Certified by Registered Engineer: Yes Installation Inspected by Unified Program Agency: Yes Manufacturer's Checklist Completed: Yes Installer Certified by Contractors' State License Board: Yes Approved Alternate methods: Date: 04/06/2000 Name:Sandy Hill Ttl:Operations & Environmental Spec. -9- 09/28/2004 .- F BEACON TRUCKSTOP #3074 p= Inventory Item 0004 F== COMMON NAME / CHEMICAL NAME DIESEL FUEL #1 SiteID: 015-021-000690 ì Facility Unit: Fixed Containers on Site ì Days On Site 365 Location within this Facility Unit Map: Grid: CAS# 8008-20-6 STATE - TYPE Liquid Pure PRESSURE Ambient TEMPERATURE Ambient CONTAINER TYPE UNDER GROUND TANK Largest Container 20000.00 GAL AMOUNTS AT THIS LOCATION Daily Maximum 20000.00 GAL Daily Average 15000.00 GAL ZARDOUS C MPONE %Wt. RS CAS# 100.00 Diesel Fuel No. 1 No 70892103 HA o NTS TSecret RS BioHaz Radioactive/Amount EPA Hazards NFPA USDOT# MCP No No No No/ Curies F IH DH / / / Low HAZARD ASSESSMENTS Ag.Defined1: MISC. LOCAL AGENCY DATA Ag.Defined2: Ag.Defined3: Ag.De~ined4: Ag.Defined6: Ag.Defined7: Ag.Defined5: Ag.Defined8: Ag.Defined9: Ag.Define10: t- Ag .Define11 -10- 09/28/2004 F BEACON TRUCKSTOP #3074 SiteID: 015-021-000690 ì f= Inventory Item 0004 Facility Unit: Fixed Containers on Site ì STORAGE CONTAINER DATA (UST FORM B and AGENCY-DEFINED) Page 1 of 2 Last Action Type: Location In Site: TANK DESCRIPTION Tank ID#: 1 Mfr: TRUSCO Installed: 3/1997 Capacity: 20000 Gals Additional Info: Compart Tank: N No. Of Comparts: Tank Use: MOTOR VEHICLE FUEL MatI Name:DIESEL FUEL #1 TANK CONTENTS Petrol Type: DIESEL Cas #: 8008-20-6 TANK CONSTRUCTION Type : DOUBLE WALL Material(p): STEEL CLAD W/FIBERGLASS R. P. Material(s): STEEL CLAD W/FIBERGLASS R. P. Lining : UNLINED Corr Prot: FIBERGLASS REINFORCED Spill Cnt : 1997 Drop Tube : 1997 Striker Plate: 1997 Sgl Wall: PLASTIC Alarm : Ball Float : Fill Tube S/O: 1997 TANK LEAK DETECTION Dbl Wall: AUTOMATIC Installed: Installed: Exempt: No TANK GAUGING INTERSTITIAL MONITORING Last Used: TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE Qty Remaining: Was Filled: No -11- 09/28/2004 ~ F BEACON TRUCKS TOP #3074 SiteID: 015-021-000690 ì f= Inventory Item 0004 Facility Unit: Fixed Containers on Site ì STORAGE CONTAINER DATA (UST FORM B and AGENCY-DEFINED) Page 2 of 2 PIPING CONSTRUCTION Piping Type : Const: Mfgr : Mtl : & : Corr : Prot : UnderGround PRESSURE DOUBLE WALL Smith FIBERGLASS AboveGround Piping FIBERGLASS FIBERGLASS PIPING LEAK DETECTION UnderGround Piping AboveGround Piping AUTOMATIC LEAK DETECTORS Installed: 09/03/1997 Date: 04/06/2000 Name:Sandy Hill Prmt Number: 0690 DISPENSER CONTAINMENT Type: FLOAT MECH. SHUTS OFF SHEAR VAL. OWNER/OPERATOR SIGNATURE Ttl:Operations & Environmental Spec. Approved: Yes Expiration Date: 06/30/2006 AGENCY DEFINED TANK/LINE TEST :07/22/2002 CP CERT. : MANWAY INSP. : UST MONIT. CERT:07/13/2004 STORAGE CONTAINER DATA (UST FORM C) Installer Certified by tank/piping manufacturer: Yes Installation Inspected & Certified by Registered Engineer: Yes Installation Inspected by Unified Program Agency: Yes Manufacturer's Checklist Completed: Yes Installer Certified by Contractors' State License Board: Yes Approved Alternate methods: Date: 04/06/2000 Name:Sandy Hill Ttl:Operations & Environmental Spec. -12- 09/28/2004 ,. F BEACON TRUCKSTOP #3074 f= Inventory Item 0003 F== COMMON NAME / CHEMICAL NAME CARBON DIOXIDE SiteID: 015-021-000690 ì Facility Unit: Fixed Containers on Site ì Days On Site 365 Location within this Facility Unit INSIDE STORAGE ROOM Map: Grid: CAS # 124-38-9 STATE - TYPE Gas Pure PRESSURE Above Ambient TEMPERATURE Ambient CONTAINER TYPE PORT. PRESS. CYLINDER Largest Container FT3 AMOUNTS AT THIS LOCATION Daily Maximum 876.00 FT3 Daily Average 657.00 FT3 HAZARDOUS COMPONENTS %Wt. RS CAS# 100.00 Carbon Dioxide No 124389 HAZARD ASSESSMENTS TSecret RS BioHaz Radioactive/Amount EPA Hazards NFPA USDOT# MCP No No No No/ Curies F P IH / / / Min Ag.Defined1: MISC. LOCAL AGENCY DATA Ag.Defined2: Ag.Defined3: Ag.Defined4: Ag.Defined5: Ag.Defined8: Ag.Defined6: Ag.Defined7: Ag.Defined9: Ag.Define10: - Ag.Define11 -13- 09/28/2004