Loading...
HomeMy WebLinkAboutHAZARDOUS WASTE (2) Environmental Management 2600 Camino Ramon, Room 2E050 San Ramon, California 94583 1510) 823-9824 Facsimile (5101 867-0241 DvLJ PACUFICU6\JBELl@ A Pacific Telesis Company dûûOO'( ~1' , î , \ . , Hazardous Materials Mana~ement Plan 1991 Pacific Bell - SA-607 - BKFDCA63 (Facility Name and ID) 101 V Street (Facility Address) Bakersfiel~ CA (Facility ity ) ¡' Certification Print Irene E. Sota Name Title Environmental Mgmt. Manager I hereby certify under penalty of perjury that the infonnation contained in thìs Hazardous Materials Management Plan is true and correct. I understand that I may be required to show proof of compliance during any facility inspection conducted by local, County, State, or Federal authorities. HazMat Reporter™ Date: 12/18/91 Facility Information General Information Facility Name Street Address Business Type EP AID # : Pacific Bell- SA-607 : 101 V Street : Construction-Maintenance : CAT080023815 Facility ID BKFDCA63 City : Bakersfield, CA Zip : 93301 D&B#: 103401618 SIC Code: 4811 Uniform Building Code Class : B-2, B-4 Mailing Address : 2600 Camino Ramon, Rm 2E050 City Billing Address : 1445 Van Ness, Rm 236 City Shift 1 Employees: 20 Shift 2 Employees: Shift 1 Start : continuous Shift 2 Start Shift 1 End Shift 2 End : San Ramon : Fresno Zip Zip Shift 3 Employees: Shift 3 Start Shift 3 End : 94583 : 93762 Facility Contacts Primary Contact : Vic Maddox Title : Site Manager Secondary Contact: Emergency Conttol Center Title : 24 hours Executive Contact : Nancy Clancy Title : Corporate Safety Representative HMMP Contact : !reneE. SOlo Title : Environmental Management Mgr. Property Owner : Pacific Bell Mailing Address : 2600 Camino Ramon, Rm 2E050 City : San Ramon, CA Work Phone #: 805-327-6567 Home Phone #: Work Phone #: (510) 823-7777 Home Phone #: Work Phone #: (415) 542-3060 Home Phone #: Work Phone #: (510) 823-9821 Home Phone #: Work Phone #: (510) 823-9824 Home Phone #: ZIP : 94583 Land Use Information Adjacent Properties Direction Business Name North Commercial South First Stteet - Residential East V Street - Light Industrial West Residential Contact Phone Special Land Uses Within 1 Mile Direction Business Name Contact Phone Water Table (ft.): UNK Earthquake Faults: None known within 1 mile Flood Zone: UNK HazMat Reporter™ Date: 12/18/91 Emergency Response Plan Facility NamePacific Bell- SA-607 Emergency Response Training All Personnel Internal Notification Yes Offsite Notification N/A ER Plan Location Yes Evac Procedures Yes Spill Procedures Yes Chemical Handlers Hand/Stor Method Yes PPE Yes SpilllFire Equip Yes Exposure Hazards Yes Facility ID BKFDCA63 Emer~encv ResDonse Team Rescue No Shutdown Yes ER Equip Maint Yes ER Procedures Yes Annual Retrain Yes Emer~encv Response Documents Verify training Yes Desc training Yes 3 years archived Yes Drill documentation Yes Evacuation Information Evacuation Notification Shouting Yes Horns Alarms Yes Evacuation Procedures Egress Yes Assembly Area Yes Maps Yes Re-entry Procedure Yes Emerl:encv Contacts Emergency Fire/Police/Ambulance State Agency Other Agency Name Other Agency Phone Nearest Med Fac Address City Phone (510) 823-7777 911 1-800-852-7550 City of Bakersfield (805)-326-3979 Call 911 for local information Other Evacuation Planning: Information Emergency Response: Pacific Bell Emergency Control Center 510-823-7777 (24 hrs. a day) Abnormal, hazardous and emergency conditions which may affect service, company buildings and/or adverse publicity should be reported to the Emergency Control Center. This organization maintains the names, home addresses and phone numbers (office and home) of contact persons who are qualified and authorized to assist federal, state and local emergency response personnel in the event of an emergency. The center is manned on a 24-hour per day, 7-day per week basis. HazMat Reporter™ Emergency Response Plan Facility Name Pacific Bell- SA-607 Date: 12/18/91 Facility ID BKFDCA63 Emergency Response Equipment Equipment Location: Motor Vehicle Shop Responsible Inspector: Vic Maddox Personal Protective Equip First-Aid Kits (1) Eye Wash Stations (1) Gloves (1) Hard Hats (1) Safety Glasses (1) Spill Control Equip Absorbent Booms (1) Fire Extinguishers (1) Neutralizers (1) Equipment Location: Tank #287 Responsible Inspector: Vic Maddox Personal Protective Equip Spill Control Equip TLS-250 (1) Location 1 of 2 Inspection Freq. Monthly Communication Devices Telephones (1) Verbal Location 2 of 2 Inspection Freq. Monthly Communication Devices HazMat Reporter™ Date: 12/18/91 Facility ID: BKFDCA63 Facility Name: Pacific Bell- SA-607 Tank Monitoring Equipment TLS-250 Inventory control monitoring of the fuel and long term tank monitoring for product leakage is accomplished with in-tank continuous product monitoring provided through the installation of the TLS-250 Tank Level Sensor manufactured by Veeder-Root. The TLS-250 consists of a Computerized Inventory Monitor (CIM) and one Digital Sending Probe (DSP) for each tank being monitored. The highly accurate, all electronic probe has no moving parts for greater accuracy and less maintenance than other electromechanical, float-type devices. A single CIM can handle multiple probes and continuously monitor each one, analyzing their signals for liquid, temperature, depth, and water level. Based on this input, the CIM computers volumes, and stores this information for remote polling. The RE-232C Serial Interface Communication port permits access to TLS-250 information from remote location via telephone lines. This serial interface is capable of handling up to 16 polling stations from centralized remote locations. The output of the serial port can be formatted for teletype or computer (IBM-PC) interface. The TLS System has three modes of operation - Leak Detection, Tank Detection, and Automatic Delivery Reporting. When the leak monitor mode is activated, the TLS System continuously monitors fuel levels in each tank and can detect losses of 0.2 gph. An hourly report on each tank shows temperature-compensated inventory changes to 0.1 gallon based on inventories when the tank leak mode is initiated. The Leak Monitor is activated through a pushbutton mounted on the front panel, or remotely through the RS-232 Telecommunications Interface. The Tank Inventory Report presents the current status of each tank. It provides station location, date and time, volume and level of fuel, water level and temperature. The Automatic Delivery Increase Report features are generated two minutes after fuel is delivered to the tank. The printout includes date, time, volume and temperature before and after the increase and the net increase of inventory. j HazMat Reporter™ Date: 12/18/91 Facility ID: BKFDCA63 Facility Name: Pacific Bell - SA-607 Emergency Response Plan SEPARATION OF MATERIALS This facility does not store material by type or quantity which requires special separation consideration. The facility was designed to prevent fIre or explosion in accordance with applicable National Fire Prevention Association Guidelines and local fire codes. The material of construction is compatible with the product stored. The tank(s) is secured to prevent unauthorized inputs or withdrawals. MONITORING PROGRAM - FUEL STORAGE TANKS The monitoring program consists of an "initial" precision leak test using the Homer "Ezy-Chek" technique (or equivalent) followed by in-tank product monitoring. RECORDKEEPING Recordkeeping is accomplished by a mechanized database that automatically polls the in-tank monitor daily. If approved by the local agency, records will be retained in the database for a period of not less than three years. Records will be made available to any agency of jurisdiction within twenty-four hours via fax. Requests for data should be called to PacifIc Bell's Fuel Unit in Fresno, (209) 442-2345. All recordable leaks and spills will be recorded on a Hazardous Material Incident Report, Form Number FR-0023. EMERGENCYEQUWMENT A number of fIre extinguishers are kept on the premises at all times. They are placed at strategic locations throughout the facility in accordance with the protection requirements of NFP A 10. Additional emergency equipment will be obtained as needed from PacifIc Bell contracted hazardous material and hazardous waste handling vendors. The fIre extinguishers are maintained and serviced by a professional outside contractor on a yearly basis. A visual inspection is made by the facility wardens on a regular basis to ensure the adequacy of the emergency equipment. CONTINGENCY PLAN Unauthorized releases (leaks and spills) of petroleum products will be recorded utilizing the Hazardous Materials Incident Report Fonn No. FR-0023 and reported by the operator of the underground storage tank immediately to the following: 1) County of Kern - Environmental Health Dept. (805) 861-3636 2) Office of Emergency Services (800) 852-7550 , HazMat Reporter™ Date: 12/18/91 Facility ID: BKFDCA63 Facility Name: Pacific Bell- SA-607 Emergency Response Plan 3) National Response Center (800) 424-8802 4) Pacific Bell Emergency Control Center (510) 823-7777 5) Environmental Management (510) 823-9824 6) Real Estate Department (510) 823-1020 7) Respective upper management within group. In case of fires, the local Fire Department and Pacific Bell Emergency Control Center will be notified promptly by the operator of the underground tank. In each step of notification, good documentation will be prepared to include: 1) Location 2) Specific description and location of the area involved 3) Time and date of occurrence 4) Description of spill and type of material 5) Approximate quantity of material that spilledlleaked All recordable leak and spill records will be maintained on the site. The key personnel on the site (Building Warden and Site Manager) are trained for responding appropriately to any major catastrophe. A training program conducted by the training department of Pacific Bell provides the information to the key personnel regarding emergency telephone numbers, reporting requirements, location of emergency equipment and evacuation procedures. This information is true and correct. If there is any change which would materially affect the Hazardous Material Management Plan, we will amend the appropriate sections. HazMat RepO11er™ Chemical Inventory DOT Waste Common or Class Code Trade Name Constituent Name FL N/A CHEVRON Supreme Gasoline, 95% Unleaded Gasoline Date: 12/18/91 Inspection District: Kern County Facility: BKFDCA63,Pacific Bell· SA-607 Map & Location: Overview,UNDERGROUND TANK·287 A Physical Max Max 1 Avg Days Cont. CAg, State Qty Vessel Qty WAT Units Site Type 68476-33·5 M,L 6000 6000 6000 N/A 365 B Heanh Press Temp Codes - - :~~~~~~~~~.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. n .. I. ·'-::·I;¡:¡;¡:¡ ID: BKFDCA63 I. Scale: None ..... ........ .p. Overview ........... .. .. . . . .. . ................ ................................................................... 'UII Residential le~t I {~ Commercial LIGHT INDUSTR IAL PAC IF IC BELL S 11E & RES IDENTIAL '.!. .;;. 101 V STREET, BAKERSFIELD I Map 1 of 1 I