Loading...
HomeMy WebLinkAbout2004 LINE TEST \ , ,¡I;> - J II' DJnlcnology 8501 N. MoPae Expressway, Suite 400 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 10/07/2004 KERN CTY - ENVIROMENTAL HEALTH 2700 M STREET SUITE 300 BAKERSFIELD, CA. 93301 Test Date: 08/06/2004 Order Number: 3135945 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7 -ELEVEN #32241 MARKET # 2133 4101 CALLOWAY DRIVE BAKERSFIELD, CA. 93312 Testing performed: Line tests Sincerely, :D~K~ Dawn Kohlmeyer Manager, Field Reporting ~ 1-. D:Jnknology CLIENT: 7-ELEVEN, INC. 20819 72ND AVE. SOUTH SUITE 206 KENT, WA 98032 RANDY MARTIN (253)796-7170 TANKNOLOGY CERTIFICATE OF TESTING 8900 SHOAL CREEK, BUILDING 200 AUSTIN, TEXAS 78757 TELEPHONE (512) 451-6334 FAX (512) 459-1459 TEST RESULT SUMMARY REPORT WORK ORDER NUMBER: 3135945 CUSTOMER PO: SITE: 7·ELEVEN #32241 MARKET # 2133 4101 CALLOWAY DRIVE BAKERSFIELD, CA 93312 MANAGER (661 )587-8826 PURPOSE: COMPLIANCE TEST DATE: 08/06/04 TEST TYPE: TLD-1 IMPACT VALVE FUNCTIO 10k 1 REG UNLEAD ENVIROFLEX PRESSURE P 0.000 Y 10k 2 MIDGRADE ENVIROFLEX PRESSURE P 0.000 Y 10k 3 PREMIUM ENVIROFLEX PRESSURE P 0.000 Y /' ',' 'I ' MO[)~t.#'?¡f:: '_'/_'?i::,,"",j,,'0~>i,i lOk :L 10k 2 10k 3 . SERIAL.# RESUL 'I For owner detailed report information, visit www.tanknology,com and select On-Line Reports-WRAP, or contact your local Tanknology office. Tester Name: WESLEY COULTER Technician Certification Number: 10004 Printed 10/07/200407:14 SBOWERS ~ INDIVIDUAL TANK INFORMATION AND TEST RESULTS S-~ Dlnknology 8900 SHOAL CREEK, BUILDING 200 AUSTIN, TEXAS 78757 (512) 451-6334 TEST DATE:08/06/04 CLlENT:7-ELEVEN, INC. Tank 10: 10k 1 Product: REG UNLEAD Capacity in gallons: 10,028 Diameter in inches: 96 . 00 length in inches: 324 Material: TOTAL CONT COMMENTS Tank manifolded: NO Vent manifolded: NO Vapor recovery manifolded: YES Overfill protection: YES Overspill protection: YES Installed: ATG CP installed on: / / TAN~T!iST'RESOLT~;Ji~~JMêtt1&d:ya,cµ,'1'êê:tJtfUt;!.x!t~t1'; Start (in) End (in) Dipped Water level: Dipped Product level: Probe Water level: Ingress Detected: Water Test time: Inclinometer reading: VacuTectTestType: VacuTect Probe Entry Point: Pressure Set Point: Tank water level in inches: Water table depth in inches: Determined by (method): Result: COMMENTS WORK ORDER NUMBER3135945 SITE:7-ELEVEN #32241 Bottom to top fill in inches: Bottom to grade in inches: Fill pipe length in inches: Fill pipe diameter in inches: Stage I vapor recovery: Stage II vapor recovery: 158.0 161. 0 62.0 4.0 DUAL ASSIST L.E.AK¡DI;~l;tT()RTESr¡~ESUlT$·.; ..., t.Y!W 1W': < fest method: F1'A New/passed Failed/replaced New/passed Failed/replaced L.D. #1 L.D. #1 L.D. #2 L.D. #2 Bubble Make: Model: SIN: Open time in see: Holding psi: Resiliency cc: Test leak rate ml/m: Metering psi: Calib. leak in gph: Results: Ullage NOT TESTED COMMENTS NOT TESTED NOT TESTED Material: Diameter (in): length (ft): Test psi: Bleedback cc: Test time (min): Start time: End time: Final gph: Result: Pump type: Pump make: COMMENTS ENVIROFLEX 1.5 175.0 50 280 60 17:38 18:38 0.000 PASS PRESSURE FE PETRO NOT TESTED Impact Valves Operational: YES NOT TESTED NOT TESTED Printed 10/07/2004 07:14 :'1 INDIVIDUAL TANK INFORMATION AND TEST RESULTS TrÞ DJnknology 8900 SHOAL CREEK, BUILDING 200 AUSTIN, TEXAS 78757 (512) 451-6334 TEST DATE:08/06/04 CLIENT: 7 - ELEVEN, INC. Tank 10: 10k 2 Product: MIDGRADE Capacity in gallons: 10,028 Diameter in inches: 96.00 length in inches: 324 Material: TOTAL CONT COMMENTS C~C'T1í;N~INf\()RM~TIC)N' Tank manifolded: NO Vent manifolded: NO Vapor recovery manifolded: YES Overfill protection: YES Overspill protection: YES Installed: ATG CP installed on: / / WORK ORDER NUMBER3135945 SITE:7-ELEVEN #32241 Bottom to top fill in inches: Bottom to grade in inches: Fill pipe length in inches: Fill pipe diameter in inches: Stage I vapor recovery: Stage II vapor recovery: 160.0 163.0 64.0 4.0 DUAL ASSIST T;y..¡K~1TESTCRE$I.JLtS¡::¡;Øl?t¡f:¢I~t~9ð:'V~~p.'t~p~~¡ ic.¡Ji¡qJi¡¡~ l~~¡I;UKfJÉ1TEctêj,1TESTRE$I.1I;.;T$c¡it!¡q ..cic:.·¡·¡¡··· Start (in) End (in) T~$~!meth()d: FTA Dipped Water level: Dipped Product level: Probe Water level: Ingress Detected: Water Test time: Inclinometer reading: VacuTect Test Type: VacuTect Probe Entry Point: Pressure Set Point: Tank water level in inches: Water table depth in inches: Determined by (method): Result: COMMENTS New/passed Failed/replaced Newlpassed Failed/replaced L.D. #1 L.D. #1 L.D. #2 L.D. #2 Bubble Make: Model: SIN: Open time in see: Holding psi: Resiliency cc: Test leak rate ml/m: Metering psi: Calib. leak in gph: Results: NOT TESTED NOT TESTED Ullage NOT TESTED COMMENTS Material: Diameter (in): length (ft): Test psi: Bleedback cc: Test time (min): Start time: End time: Final gph: Result: Pump type: Pump make: COMMENTS ENVIROFLEX 1.5 175.0 50 194 60 17:38 18:38 0.000 PASS PRESSURE FE PETRO NOT TESTED Impact Valves Operational: YES NOT TESTED NOT TESTED Printed 10/07/200407:14 ." INDIVIDUAL TANK INFORMATION AND TEST RESULTS r~ DJnlmology 8900 SHOAL CREEK, BUILDING 200 AUSTIN, TEXAS 78757 (512) 451-6334 TEST DATE:08/06/04 CLlENT:7-ELEVEN, INC. Tank ID: 10k 3 Product: PREMIUM Capacity in gallons: 10,028 Diameter in inches: 96.00 Length in inches: 324 Material: TOTAL CONT COMMENTS .·y\k.k,¿.TANKINFORMATIONk.y Tank manifolded: NO Vent manifolded: NO Vapor recovery manifolded: YES Overfill protection: YES Overspill protection: YES Installed: ATG CP installed on: / / WORK ORDER NUMBER3135945 SITE:7-ELEVEN #32241 Bottom to top fill in inches: Bottom to grade in inches: Fill pipe length in inches: Fill pipe diameter in inches: Stage I vapor recovery: Stage II vapor recovery: 157.0 160.0 61. 0 4.0 DUAL ASSIST .TAN«1E$T:RE$uL"s"'~itfM~~ø.f:gr¡·l'~~~~~~~%t.Íf'J:<;;·~kk¡;;·';¡ '!11t;~bETEbtÖR·T~t~ESt:Jt~··, C"" . '" ;'Tes{ffiefhod: FTA, S~rtO~ EndO~ Dipped Water Level: Dipped Product Level: Probe Water Level: Ingress Detected: Water Test time: Inclinometer reading: VacuTect Test Type: VacuTect Probe Entry Point: Pressure Set Point: Tank water level in inches: Water table depth in inches: Determined by (method): Result: COMMENTS New/passed L.D.#1 Bubble Make: Model: SIN: Open time in sec: Holding psi: Resiliency cc: Test leak rate mllm: Metering psi: Calib. leak in gph: Results: Ullage NOT TESTED COMMENTS Material: Diameter (in): Length (ft): Test psi: Bleedback cc: Test time (min): Start time: End time: Final gph: Result: Pump type: Pump make: COMMENTS ENVIROFLEX 1.5 175.0 50 182 60 17:38 18:38 0.000 PASS PRESSURE FE PETRO NOT TESTED Impact Valves Operational: YES Failed/replaced New/passed Failed/replaced L.D. #1 L.D. #2 L.D, #2 NOT TESTED NOT TESTED D NOT TESTED NOT TESTED Printed 10/07/200407:14 ." ~~ DJnlmology 8900 SHOAL CREEK, BUILDING 200 AUSTIN, TEXAS 78757 (512) 451·6334 FAX (512)459-1459 TEST DATE:08/06/04 CLlENT:7-ELEVEN, INC. WORK ORDER NUMBER3135945 SITE:7-ELEVEN #32241 COMMENTS Arrived on site at 5:00 P.M. for primary piping testing. PARTS REPLACED HELIUM PINPOINT TEST RESULTS (IF APPLICABLE) Printed 10/07/200407:14 SBOWERS .., .. SITE DIAGRAM t-., Tånknology 8900 SHOAL CREEK, BUILDING 200 AUSTIN, TEXAS 78757 (512) 451-6334 FAX (512) 459-1459 TEST DATE: 08/06/04 CLIENT: 7 - ELEVEN I INC. WORK ORDER NUMBER3135945 SITE: 7 -ELEVEN #32241 4E (XX) VENTS 0 0 0 ø ø ø c eo 0 0~ ~ EN Jf Jf Q)..... ..... C)M ~ -.:teoM 0 0 0 "loCO> ..... ..... ..... N@)~ M eo : :t: 0 B B B >- - ceo" Q)~ã) >o¡¡:: ~=(/) Jf Jf Q) eo ..... ~o~ PLUS SUP UL .....eo 0.0 ..... -.:t Printed 10/07/200407:14 SBOWERS