HomeMy WebLinkAboutAST-REPORT 12/10/1997 .' -'> .....~--~----------------- -- --- (805) 323-1032 (800) 552-0123 Jerry Tallman 610 Williams Street Bakersfield, CA 93305 --- -- - --------.--,--. >k . e - BAKERSFIELD FIRE DEPARTMENT December 10, 1997 FIRE CHIEF MICHAEL R, KEllY Tim Sullivan Sullivans Petroleum 2337 Eye Street Bakersfield, CA 93301 ADMINISTRAßVE SERVICES 2101 ow Street Bakersfield, CA 93301 (805) 326-3941 FAX (805) 395-1349 RE: Above Ground Storage Tank Located at 610 Williams Street SUPPRESSION SERVICES 2101 ow Street Bakersfield, CA 93301 (805) 326-3941 FAX (805) 395-1349 Dear Mr. Sullivan: A business plan submitted on December 1,1997 by Mr. Jerry Tallman of TBL Charter Lines, indicated that a 1,000 gallon above ground tank had been added PREVENnON SE~ES '_"h_ _,__, tc? the.ir i!l:ye.lltEry. ~in~~ _ouroffice had no pennit for this tank, an inspection was . 1715 Chester Ave. .,' " ,,- --". , ',' - ,- ,'-'- --, .." "' .'... ..-, ---~...--,-, ~~,"" Bakersfield, CA 93301' . perfonned at the above referenced address on December 10, 1997. The purpose of.. (805) 326-3951 this inspection was to: FAX (805) 326-0576 TRAINING DIVISION 5642 Victor Street Bakersfield, CA 93308 (805) 399-4697 FAX (805) 399-5763 1. Verify the existence of one 1,000 gallon above ground diesel tank. 2. Confinn that it meets the Unifonn Fire Code. 3. Confinn the date this tank went into service (which was approximately 11/2 years ago). ENVIRONMENTAL SERVICES 1715 Chester Ave, Bake.rsfield, CA 93301 (805) 326-3979 FAX (805) 326-0576 As you mayor may not be aware, all above ground tanks must be pennitted prior to installation. This is to insure that your tank meets the Uniform Fire Code. During our exit interview with Terry Tallman, we were infonned that you are the owner of this tank, and have provided it for Mr. Tallmans exclusive use. Accordingly, I must infonn you that your tank does not meet the Uniform Fire Code (1994 Edition) requirements for dispensing motor vehicle :fuel for the following reasons: 1. Your tank design does not have fire-resistive protection from high intensity fire exposure. 2. Your tank design does not have projectile protection. 3. Your tank does not have overfill and overspill protection. 4. Your tank does not have crash posts for vehick impact protection. 5. Your tank has not been permitted. 'Y~~ W~ STeve.A~ ~..Æ W~ " -_. ~ '~- - e e You are therefore required to remove your 1,000 gallon above ground tank from service with within fifteen (IS) days ( December 25, 1997). I am enclosing copies of the Uniform Fire Code (1994 Edition) Section II-F on dispensing motor vehicle fuel, as a reference. Should you have any questions, please feel free to call me at 326-3979. Sincerely, Ralph E. Huey Hazardous Materials Coordinator by: ~dt£J Steve Underwood Inspector . . - ----.---..- . _h~_ __>_ _ SBU/dm cc: Jerry Tallman, TBL Charter Lines dmll cc TRAVEL BY LAND " '''~ I /:-;,J!-;~,,". ~~--- ~, -::--..., ..... "" "-':::-- "....~.,. ::;;;;;:::_, November 26, 1997 City of Bakersfield Office of Environmental Services 1715 Chester Avenue Bakersfield, CA., 93301 RE: Site ID No. 215-000-001031 Attention: Ralph E. Huey Dear Mr. Huey: Please find enclosed the completed additional of the 1,000 gallons diesel fuel that is at the rear of our property, just West of the shop building~ Should there be any further information or questions, please call. Thank you. JT:km enclosure(s) 610 Williams St. . Bakersfield, CA 93305,. (805) 323-1032