HomeMy WebLinkAboutBUSINESS PLAN (4)
,::;------
"
THIARA FOOD MART
SiteID: 015-021-001284
Manager : SATNAM SINGH
Location: 3401 S CHESTER AVE
City BAKERSFIELD·
BusPhone:
Map : 103
Grid: 19C
(661) 832-5900
CommHaz : Low
FacUnits: 1 AOV:
CommCode: BAKERSFIELD STATION 05
EPA Numb:
SIC Code:
DunnBrad:
Emergency Contact
SATNAM SINGH
Business Phone:
24-Hour Phone :
Pager Phone :
/ Title
/ OWNER/OPERATOR
(661) 832-5900x
(661) 458-6221x
(661) 634 -7001x
Emergency Contact /
"XE'fnR SINGH \4:: \..H:t~ /
Business Phone: (661)
24-Hour Phone : (661)
Pager Phone : ( )
Title
832-5900x
843-7101x
- x
Hazmat Hazards:
Fire
ImmHlth DelHlth
Period :
Preparer:
Certif'd:
parcelNo:
to
Phone: (661) 832-5900x
State: CA
Zip : 93304
Phone: (661) 832-5900x
State: CA
Zip : 93304
TotalASTs: = Gal
TotalUSTs: = Gal
RSs: No
Contact : SATNAM SINGH
MailAddr: 3401 S CHESTER AVE
City : BAKERSFIELD
Owner
Address :
City
SATNAM SINGH
3401 S CHESTER AVE
: BAKERSFIELD
Emergency Directives:
(
I, ~l ~1f\)~1( SIb&lL D
(TypeOtprlntname) 0 hereby certify that' have
reviewed the attached hazardous materials manage-
ment plan for "'W;'"'f\tJ.A.Ç(
(Nameor~~r:)~land that it along with
any corrections constitute a complete and C
orrect man-
agement plan for my faciUty.
'"
~~
OJ -2fJ-Ô'i
Doft
-1-
09/27/2004
':(,
t"
F THIARA FOOD MART
SiteID: 015-021-001284 ì
STORAGE CONTAINER DATA (UST FORM A)
Last Action Type:
FACILITY/SITE INFORMATION
Business Name: THIARA FOOD MART
Cross Street :
Business Type: Org Type:
Total Tanks : 2 IndnRes/Trust: No PA Contact:
PROPERTY OWNER INFORMATION
Name : KETTAR SINGH Phone: (661) 832-5900x
Address:
City : State: Zip:
Type : INDIVIDUAL
TANK OWNER INFORMATION
Name : KETTAR SINGH Phone: (661) 832-5900x
Address:
City : State: Zip:
Type : INDIVIDUAL
BOE UST Fee# : UNKNOWN
Financ'l Resp: SELF INSURED
Legal Notif :
Date:03/04/2002 Phone: (661) 832-5900x
Name:SATNAM SINGH Ttl:OWNER
State UST # : 1998 Upg Cert#: 00833
-2 -
09/27/2004
i'
SiteID: 015-021-001284
By Facility Unit
Fixed Containers on Site
ì
ì
ì
DailyMax IUnitMCP
10000.00 GAL Mod
10000.00 GAL Mod
F THIARA FOOD MART
f= Hazmat Inventory
f== MCP+DailyMax Order
Hazmat Common Name...
specHazEPA HazardS Frm I
REGULAR UNLEADED
PREMIUM UNLEADED
F
F
IH DH
IH DH
L
L
-3-
09/27/2004
SiteID: 015-021-001284 ì
Facility Unit: Fixed Containers on Site ì
F THIARA FOOD MART
f= Inventory Item 0001
=== COMMON NAME / CHEMICAL NAME
REGULAR UNLEADED
Days On Site
365
Location within this Facility Unit
N SIDE LOT
Map:
Grid:
CAS#
8006-61-9
STATE - TYPE
Liquid Pure
PRESSURE
Ambient
TEMPERATURE
Ambient
CONTAINER TYPE
UNDER GROUND TANK
Largest Container
10000.00 GAL
AMOUNTS AT THIS LOCATION
Daily Maximum
10000.00 GAL
Daily Average
5000.00 GAL
%Wt. I
100.00 Gasoline
HAZARDOUS COMPONENTS
[æ]
No
CAS # I
8006619
TSecret RS BioHaz Radioactive/Amount EPA Hazards NFPA USDOT# MCP
No No No No/ Curies F IH DH / / / Mod
HAZARD ASSESSMENTS
Ag.Defined1:
MISC. LOCAL AGENCY DATA
Ag.Defined2: Ag.Defined3: Ag.Defined4:
Ag.Defined5:
Ag.Defined6: Ag.Defined7:
Ag.Defined8:
Ag.Defined9: Ag.Define10:
- Ag.Define11
-4-
09/27/2004
F THIARA FOOD MART SiteID: 015-021-001284 9
f= Inventory Item 0001 Facility Unit: Fixed Containers on Site 9
STORAGE CONTAINER DATA (UST FORM B and AGENCY-DEFINED) Page 1 of 2
Last Action Type:
Location In Site: NSIDE LOT
TANK DESCRIPTION
Tank ID#: 1 Mfr: UNKNOWN
Installed: 12/1975 Capacity: 10000 Gals
Additional Info: SYSTEM WAS LINED IN 1997
TANK CONTENTS
Tank Use: MOTOR VEHICLE FUEL Petrol Type:
Matl Name:REGULAR UNLEADED
TANK CONSTRUCTION
Type : SINGLE WALL W/INT LINER & C.P.
Material(p): BARE STEEL
Material(s): BARE STEEL
Lining : EPOXY LINING
Corr Prot: CATHODIC PROTECTION
Spill Cnt : 1998
Drop Tube : 1998
Striker Plate: 1998
Compart Tank: N
No. Of Comparts:
REGULAR UNLEADED
Cas #: 8006-61-9
TANK LEAK
Sgl Wall: AUTOMATIC TANK GAUGING
Alarm :
Ball Float :
Fill Tube S/O:
DETECTION
Dbl Wall:
Installed:
Installed:
Exempt: No
1998
Last Used:
TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE
Qty Remaining: Was Filled: No
-5-
09/27/2004
F THIARA FOOD MART SiteID: 015-021-001284 ì
f= Inventory Item 0001 Facility Unit: Fixed Containers on Site ì
STORAGE CONTAINER DATA (UST FORM B and AGENCY-DEFINED) Page 2 of 2
PIPING CONSTRUCTION
UnderGround Piping
PRESSURE
DOUBLE WALL
AboveGround Piping
Type:
Const:
Mfgr :
Mtl :
& :
Corr :
Prot :
"FLEX"
PIPING LEAK DETECTION
UnderGround Piping AboveGround Piping
AUTOMATIC LEAK DETECTORS
Installed: 11/24/1997
Date: 03/04/2002
Name:SATNAM SINGH
Prmt Number: 1284
DISPENSER CONTAINMENT
Type: DISP. PAN SENSOR w/ POS. SHUTOFF
OWNER/OPERATOR SIGNATURE
Ttl:OWNER
Approved: Yes Expiration Date: 06/30/2006
AGENCY DEFINED
TANK/LINE TEST :01/27/1998
CP CERT. :07/10/2003
MANWAY INSP. : 12/22/1998
UST MONIT. CERT:05/19/2004
-6-
09/27/2004
SiteID: 015-021-001284 ì
Facility Unit: Fixed Containers on Site ì
F THIARA FOOD MART
f= Inventory Item 0002
i== COMMON NAME / CHEMICAL NAME
PREMIUM UNLEADED
Days On Site
365
Location within this Facility Unit
N SIDE LOT
Map:
Grid:
CAS#
8006-61-9
STATE - TYPE
Liquid Pure
PRESSURE
Ambient
TEMPERATURE
Ambient
CONTAINER TYPE
UNDER GROUND TANK
Largest Container
10000.00 GAL
AMOUNTS AT THIS LOCATION
Daily Maximum
10000.00 GAL
Daily Average
5000.00 GAL
%Wt. I
100.00 Gasoline
HAZARDOUS COMPONENTS
~
CAS # I
8006619
TSecret RS BioHaz Radioactive/Amount EPA Hazards NFPA USDOT# MCP
No No No No/ Curies F IH DH / / / Mod
HAZARD ASSESSMENTS
Ag.Defined1:
MISC. LOCAL AGENCY DATA
Ag.Defined2: Ag.Defined3: Ag.Defined4:
Ag.Defined5:
Ag.Defined6: Ag.Defined7:
Ag.Defined9: Ag.Define10:
Ag.Defined8:
- Ag.Definell
-7-
09/27/2004
"
F THIARA FOOD MART SiteID: 015-021-001284 ì
p= Inventory Item 0002 Facility Unit: Fixed Containers on Site,
STORAGE CONTAINER DATA (UST FORM B and AGENCY-DEFINED) Page 1 of 2
Last Action Type:
Location In Site: N SIDE LOT
TANK DESCRIPTION
Tank ID#: 2 Mfr: UNKNOWN
Installed: 12/1975 Capacity: 10000 Gals
Additional Info: TANKS LINED IN 1997
TANK CONTENTS
Tank Use: MOTOR VEHICLE FUEL Petrol Type:
MatI Name:PREMIUM UNLEADED
TANK CONSTRUCTION
Type : SINGLE WALL W/INT LINER & C.P.
Material(p): BARE STEEL
Material(s) :
Lining : EPOXY LINING
Corr Prot: CATHODIC PROTECTION
Spill Cnt : 1998
Drop Tube :
Striker Plate:
Compart Tank: N
No. Of Comparts:
PREMIUM UNLEADED
Cas #: 8006-61-9
TANK LEAK
Sgl Wall: AUTOMATIC TANK GAUGING
Alarm :
Ball Float :
Fill Tube S/O:
DETECTION
Dbl Wall:
Installed:
Installed:
Exempt: No
1998
Last Used:
TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE
Qty Remaining: Was Filled: No
-8-
09/27/2004
",,"
F THIARA FOOD MART SiteID: 015-021-001284 9
f= Inventory Item 0002 Facility Unit: Fixed Containers on Site ì
STORAGE CONTAINER DATA (UST FORM B and AGENCY-DEFINED) Page 2 of 2
PIPING CONSTRUCTION
UnderGround Piping
PRESSURE
DOUBLE WALL
AboveGround Piping
Type:
Const:
Mfgr :
Mtl :
& :
Corr :
Prot :
"FLEX"
PIPING LEAK DETECTION
UnderGround Piping AboveGround Piping
AUTOMATIC LEAK DETECTORS
Installed: 11/24/1997
Date: 03/04/2002
Name:SATNAM SINGH
Prmt Number: 1284
DISPENSER CONTAINMENT
Type: DISP. PAN SENSOR W/ POS. SHUTOFF
OWNER/OPERATOR SIGNATURE
Ttl:OWNER
Approved: Yes Expiration Date: 06/30/2006
AGENCY DEFINED
TANK/LINE TEST :01/27/1998
CP CERT. :07/10/2003
MANWAY INSP. : 12/22/1998
UST MONIT. CERT:05/19/2004
.
-9-
09/27/2004