Loading...
HomeMy WebLinkAbout315 EAST 18TH STREETCity of Bakersfield Fire Dept Fire Sprinkler Plans Sc'armed By Delta Microlmaging Inc. 9961 N. Lower Sacramento Rd. Stockton, Ca 95210 209-478-3600 PERMIT INFO ~ ~ Permit No..: Applied..: 12/06/2000 Permit Type: Approved.: Type ....... : Completed: Stares ..... : READ To Expire: LOCATION Job Address: 315 E 18TH ST BAK Location...: Description: FIRE ALARM INSTILLATION Tr/No/Lot..: TR Parcel...: ?? Zone ....... : ?? SPR No...: CONSTRUCTION Code ....... : 1998 CBC PEOPLE Owner ...... : SANDSTONE CHARTER SCHOOL Phone No.: Applicant..: TEL TEC SECURITY SYSTEMS INC Phone No.: Arch/Engr..: Phone No.: Comractor.: PhoneNo.: 397-5511 Cont LicNo: 472338 Exp Date.: 04/30/2001 Cont Addr..: FEES Plan Check.: $150.00 Total Sq Ft...: 0 Inspection.: $151.00 Fire Valuation: $0.00 Tot Calc Fee..: $301.00 Additonal Fee.: $0.00 Tot Permit Fee: $301.00 Payments ...... : $0.00 Balance Due...: $301.00 Appendix A Compatible Devices This section of the manual lists devices (smoke detectors and notification appliances) that are compatible with the 5207. Contact Silent Knight if you have a question about whether a device not listed here is compatible. A.1 Smoke Detectors This section of the manual contains information about smoke detectors that are compatible with the 5207. 5207 5210 Identifier 24D 24A Voltage Range 19.4-28 VDC 17.8-27.4 VDC Notes: The maximum number of smoke detectors per zone is determined by both the current draw and the impedance of the smoke detector. If too many smoke detctors are used on any zone, false alarms could occur. Do not mix different models of detectors On any zone; false alarms could occur. Control unit Smoke Reset 7~me must be programmed for a number greater than or equal to the maximum reset time of the smoke detector. Two-Wire Smoke Detectors The table below lists two-wire smoke detectors that are compatible with the 5207. The table is organized by manufacturer. Information for both 12V and 24V mode and for the 5210 Zone Expander Module is included. The columns show the number of detectors per loop that Can be used. Model Name or Number 5207 5210 Manufacturer (Base model name or number in parentheses.) Apollo 55000-250 (45681-200) 24 / loop 8 / loop Apollo 55000-350 (45681-200) 24 / loop 8 / loop Detection Systems DS200 (MB200-2W) 24 / loop 12 / loop Detection Systems DS200HD (MB200-2W) 24 / loop 12 / loop Detection Systems DS250 (MB2W or MB2WL) 18 / loop 8 / loop Detection Systems DS250HD (MB2W or MB2WL) 18 / loop 8 / loop Detection Systems DS250TH (MB2W or MB2WL) 18 / loop 8 / loop ESL 425 40/loop 20 / loop ESL 425C 40 / loop 20 / loop ESL 425CR 40 / loop 20 / loop ESL 425CRT. 40 ! loop 20 / loop ESL 425CT 40 / loop 20 / loop ESL 429C (S10A) 30 / loop 14 / loop ESL 429CRT (SllA) 30 / loop 14 / loop 150865 A- 1 Model 5207 Fire Control/Communicator Installation and Operation Manual Model Name or Number 5207 5210 MalltlfactlJrer (Base model name or number in paren, theses.) ESL 429CST'(SilA) 30 / loop 14 / loop ESL 429CT (S10A) 30 / loop 14 / loop ESL 609U01-11 '40 / loop 24 / loop ESL 609U02-11 40 / loop 24 / 10op ESL 611U (601U or 602U) 40 / loop 24 / loop ESL 611UD (601U or 602U) 40 / loop 24 / loop EsL 611UT (601U or 602U) 40 / loop 24 / loop ESL 612U (601U or 602U) 40 / loop 24 ~ loop ESL 612UD (601U or 602u) 40'/loop 24 / loop ESL 711u (701E or 701U) 25 / loop 15 / loop ESL 712U (701E or 701U) 25 / loop 15 / loop ESL 713-5U (702E or 701U) 25 / loop 15 / loop ESL 713-6U (702E or 701U) 25 / loop 15 / loop ESL 721-U (S10A) 30 / loop 15 / loop ESL 721-UT (S10A) 30 / loop 15 / lo°p Falcon 525 17 / loop 8 / loop Falcon 525T 17 / loop 8 / loop Faraday 9374 20 / loop 10 / loop Faraday 9375 20 / loop 10 / loop Faraday 9376 20 / loop 10 / loop Hochiki SIH-24F (HS-224D or HSB-224) 25 / loop 10 / loop Hochiki SLK-12 25'/loop 10 / loop Hochiki SLK-24F (HS-224D) 25 / loop 10 / loop Hochiki SLK-24FH (HS-224D) 25 / loop 1'0 / looP Hochiki (HS224L) Heat Detector base 30 / loop 30 / loop System Sgnsor 1100 20 / loop 8 / loop System Sensor ll00T 20 / loop 8 / loop System Sensor 1100TB 20 / loop 8 / loop System Sensor i151 (ll0LP) 20 / loop, 8 / loop System Sensor 1400 20 / loop 8 / loop System Sensor 1451 (B401B) 20 / loop 8 / loop System Sensor 1800 20 / loop 8 / loop System Sensor 1851B (B101B) 20 / loop 8 / loop System Sensor 1851DH (DH1851DC) 20 / loop 8 / loop System Sensor 2100 20 / loop 8 / loop System Sensor 2100T 20 / loop 8 / loop System Sensor 2100TB 20 / loop 8 / loop System Sensor 2151 (Bll0LP or B110LRP) 20 / loop 8 / loop System Sensor 2300T 20 / 10op 8 / loop System Sensor 2400 20 / loop 8 / loop System Sensor 2400 (DH400) 20 ! loop 8 ! loop' System sensor 2400AIT 20 / loop 8 / loop System Sensor 2400AT 20 / loop 8 / loop System Sensor 2400TH 20 / loop 8 / loop' A-2 150865 Model Name or Number 5207 5210 Manufacturer (Base model name or number in parentheses.) System Sensor 2451 (B401B) 20/loop 8 / loop System Sensor 2451DH (DH 400) 20 / loop 8 / loop System Sensor 2451TH (B401B) 20 / loop 8 / loop System Sensor 2800 20 / loop 8 / loop "System Sensor 2800TH 20 / loop 8 / loop 'S~stem Sensor 2851B (B101B) 20 / loop 8 / loop System Sensor 2851BTH (B101B) 20 / loop 8 / loop System Sensor 2851DH 20 / loop 8 / loop System Sensor 2851TH (B 10lB) 20 / loop 8 / loop Four Wire Smoke Detectors Manufacturer Model Silent K~ght SD-P24F with SD-B4@ base Detection Systems DS200/DS200HD MB200 ESL 445 Series 449 Ser~es System Sensor 185 lB 2851/2851BTH DH200ADCD A.2 Notification Appliances The chart below lists notification appliances compatible with the 5207. Manufacturer Model Type Faraday 446X 12/24VDC Vibrating Bell Faraday 476X 12/24VDC Vibrating Bell Faraday 477X 12/24VDC Single Stroke Bell Faraday 5303B-0-14-( )-DC Chime (flush) Faraday 5304B-0-14-( )-DC Chime (surface) Faraday 5305B-0-4-( )-DC Chime (ceiling) Faraday 5306B-0-14-( )-24-DC Chime/Strobe (flush) Faraday 5307B-0-14-( )-24-DC Chime/Strobe (surface) 'Faraday 5308B-0-4-( )-24-DC Chime/Strobe (ceiling) Faraday 5333B-0-14-24-DC Multi-Tone Horn (flush) Faraday 5334B-0-14-24-DC Multi-Tone Horn (surface) Faraday 5336B-( )-14-24-DC Multi-Tone Horn/Strobe (flush) Faraday 5337B-( )-14-24-DC Multi-Tone Horn/Strobe (surface) Faraday' 5338B-( )-4-24-DC Multi-Tone Horn/Strobe (ceiling) Faraday 5343B-0-14-24-DC Single Tone Horn/Strobe (flush) Faraday 5344B-0-14-24-DC Single Tone Horn/Strobe (surface) Faraday 5345B-0-4-24-DC Single Tone Horn/Strobe (ceiling) Faraday 5348B-( )-4-24-DC Single Tone Horn/Strobe (ceiling) 150865 A-3 Model 5207 Fire Control/Communicator Installation and Operation Manual Manufacturer Model Type Faraday 5373B-0-14:24-DC 8~Tone Horn/Strobe (flush) Faraday 5374B-0-14-24-DC ~ 8-Tone Horn/Strobe (surface) Faraday 5375B-0-4-24-Dc 8-Tone Horn/Strobe (ceiling) Faraday 5376B-0-14-24-DC 8-Tone Horn/Strobe (flush) Faraday 5377B-0-14-24-DC 8-Tone Horn/strobe (surface) Faraday 5378B-0-4-24-DC 8-Tone Horn/Strobe (ceiling) Faraday 5405B-0-14-24-DC Sync Control Unit Faraday 5508B-( )-14-24-DC Single Gang Sync Strobe (flush) Faraday 5521B-( )-14-24-DC 4" Square Sync Strobe (surface) Faraday 5522B-( )-14-24-DC 4" Square Sync Strobe (flush) Faraday 6126B-U- 14-24 VDC Horn/Strobe Faraday 6223B-0-14-24-DC Horn (flush) Faraday '6224B-0-14-24-DC Horn (surface) Faraday 6225B-0-4-24-DC Horn (ceiling) Faraday 6226B-( )-i4-24-DC Horn/Strobe (flush) Faraday 6227B-( )-14-24-DC Horn/Strobe (surface) Faraday 6228B-( )-4-24-DC Horn/Strobe (ceiling) Faraday 6243B-0-14~24-DC Electron-Mechanical Horn (flush) Faraday 6244B-0-14-24-DC Electron-Mechanical Horn (surface) Faraday 6245B-0-4-24-DC Electron-Mechanical Horn (ceiling) Faraday 6246B-( )- 14-24-DC Electron-Mechanical Horn/Strobe (flush) Faraday 6247B-( )- 14-24-DC Electron-Mechanical Horn~Strobe (surface) Faraday 624.8B-( )-4-24-DC Electron-Mechanical Horn/Strobe (ceiling) Faraday 6300B -0-14-24-DC Mini-Horn (flush) Fhraday 6301B-0-14-24-DC Mini-Horn (surface) Faraday 6302B-( )-4-24-DC Mini-Horn (ceiling) Faraday 6310B-0-14-24-DC Mini-Horn/Strobe/Strobe (flush) Faraday 631 lB'-0-14-24-DC Mini-Horn/Strobe/Strobe (surface) Faraday 6312B-( )- 14-24-DC Mini-Horn/Strobe/Strobe (ceiling) Faraday 6320B-0-14-24-DC Sync Mini Horn/Strobe (1 gang) Faraday 6321B-0-14-24~DC Sync Mini Horn/Strobe (1,2 gang) Faraday 6322B-( )-14-24-DC Mini Horn/Sync Strobe (1,2 gang, 4SQ) Federal Signal 450 Horn Federal Signal VALS Horn/Strobe Gentex GX90-4 Horn Gente x GXS-4-15-1 Strobe Gentex GXS-4-1575 Strobe Gentex GX90S-4-15 Horn Gentex GX90S-4-1575 Horn Gentex HG124 Horn Gentex SHG24-1575 Horn/Strobe Gentex SHG24-15 Hom/Strobe Gentex GMH-24-X Horn A-4 150865 Manufacturer Model Type Gentex GMS-24-X Horn/Strobe ' Gentex GMS-24-X Horn/Strobe Gentex 'GOT24 Horn Gentex GOS24-X Horn Gentex WGMS-24-X Horn/Strobe System Sensor MASS241 Horn/Strobe "'System Sensor MASS 24110ADA Horn/Strobe System Sensor MASS2415ADA Horn/Strobe 'System Sensor MASS2475ADA Horn/Strobe System Sensor SS4110ADA Strobe 'System Sensor SS2415ADA Strobe System Sensor SS2475ADA Strobe System Sensor PS2415ADA Mini-Horn/Strobe System Sensor PS241575ADA Mini-Horn/Strobe System Sensor PS24110ADA Mini-Horn/Strobe System Sensor PS2475ADA Mini-Horn/Strobe Wheelock 46T-G4-24-R Bell Wheelock 46T-G6-24-R Bell Wheelock 46T-G 10-24-R Bell Wheelock 46T-G6-24-WS-24-HF-R Strobe/B ell Wheelock 46T-G 10-24-WS-24-HF-R Strobe/Bell Wheelock 46T-G6-24-WH-24-HF-R' Strobe/Bell Wheelock 46T-G 10-24-WH-24-HF-R Strobe/Bell Wheelock 700 IT- 12\24-W-FR Strobe Horn Wheelock 7002T- 12L24-W-FR Strobe Horn Wheelock AES-DL1-R Multitone Horn Wheelock AES-EL1-R Multitone Horn 'Wheelock AES-DLl-WS-24-VF-R Multitone Horn Wheelock AES-ELl-WS-24-VF-R Multitone Horn Wheelock AES-DL1-WH-24-VF-R Multitone Horn Wheelock AES-EL1-WH-24-VF-R Multitone Horn Wheelock AES-DL1-WM-24-VF-R Multitone Horn Wheelock AES-EL1-WM-24-VF-R Multitone Horn Wheelock AH-24-R Horn Wheelock AMT- 12\24-R Strobe Horn Wheelock AMT-24-LS-VFR Strobe Horn Wheelock AMT-24-LSM-VFR Strobe Horn Wheelock AMT-24-IS-VFR Strobe Horn Wheelock AS-2415-VFR Strobe Horn Wheelock AS-241575-VFR Strobe Horn Wheelock AS-2430-VFR Strobe Horn Wheelock AS-2475-VFR Strobe Horn Wheelock AS-24110-HFR Strobe Horn Wheelock SM- 12\24-R Strobe Horn Controller Wheelock DSM- 12\24-R Strobe Horn Controller 150865 A-5 Model 5207 Fire Control/Communicator Installation and Operation Manual Manufacturer Model Type ~l~ Wheel0ck CF-BF1 Chime Wheelock CF-B F 1 -R Chime Wheelock CH-CF 1 Chime Wheelock CH-CF 1-R Chime Wheelock cH-CF 1-W Chime Wheelock CH-DF 1 Chime Wheelock CH-DF 1-R Chime Wheelock CH-BF1 oWS-24-HF-R Strobe Chime Wheelock CH-CF1-LS-24 Strobe Chime Wheelock CH-CF1-MS~24 Strobe Chime Wheelock CH-CFI-IS-24 Strobe Chime Wheelock CH-CF1-LS-24-CFW Strobe Chime Wheelock CH-CF1-MS-24-CFW Strobe Chime Wheelock CH-CFl-IS-24-CFW Strobe Chime Wheelock CH-CF1-WS-24-CF-W Strobe Chime Wheelock CH-DF1-LS-24 Strobe Chime Wheelock CH-DF I-MS-24 Strobe Chime Wheelock CH-DF 1-IS-24 Strobe Chime Wheelock CH-DF 1-LS-24-VFR Strobe Chime Wheel0ck CH-DF1-LSM-24-VFR Strobe Chime Wheelock CH-DF1-MS-24-vFR Strobe Chime Wheelock CH-DFl-IS~24-VFR Strobe Chime Wheelock CH-DFl-WM-24-VFR Strobe 'Chime Wheelock CH-DFl-WS-24-VF-R Strobe Chime Wheelock DSM- 12/24 Sync Module Wheelock EH-DL1-R Electronic Horn Wheelock / EH-EL1-R Electronic Horn Electronic Horn Wheelock EHS-DL1-W-VF-R Strobe Horn (single input) Wheelock EHS-ELI-W-VF-R Strobe Horn (single inPut) Wheelock EH-DL1-WS-24-VF-R Strobe Horn (dual input) Wheelock EH-EL1-WS-24-VF-R Strobe Horn (dual input) Wheelock EH-DL1-WH-24-VF-R Strobe Horn (dual input) Wheelock EH-EL1-WH-24-VF-R Strobe Horn (dual input) Wheelock EH-DL1-WM-24-VF-R Strobe Horn (dual input) Wheelock EH-EL1-WM-24-VF-R Strobe Horn (dual input) Wheelock HSW-24-HFR Remote Strobe Wheelock HS2W-24-HFR Remote Strobe Wheelock HSPW-24-HFR Remote Strobe Wheelock IS-24-VFR Remote Strobe Wheelock IS 1-24-VFR Remote Strobe Wheelock IS3-24-VFR Remote Strobe Wheelock ISP-24-HFR Remote Strobe Wheelo~k LS-24-VFR Remote Strobe Wheelock LS 1-24-VFR Remote Strobe ~ Wheelock LS3-24-VFR Remote Strobe A-6 150865 Manufacturer Model Type Wheelock LSP-24-HFR Remote Strobe Wheelock LSM-24-VFR Remote Strobe wheelock LS1M-24-VFR Remote Strobe Wheelock LS3M-24-VFR Remote Strobe Wheelock LSPM-24-VFR Remote Strobe Wheelock MS-24-VFR Remote Strobe Wheelock MS 1-24-VFR Remote Strobe Wheelock MS3-24-VFR Remote Strobe 'Whe~lock MSP-24-HFR Remote Strobe 'Wheelock MB-G6-24-R Motor Bell' Wheelock MB-G10-24-R Motor Bell 'Wheelock MBS-G6-24-W-HFoR Motor Bell with Strobe Wheelock MBS-G10-24-W-HF-R Motor Bell with Strobe Wheelock MIZ-24-R Mini-Horn Wheelock MIZ-24-W Mini-Horn Whe~iock MIZ-24-LS-VFR Mini-Horn/Strobe Wheeiock MIZ-24-LSM-VFR Mini-Horn/Strobe Wheelock MIZ-24-MS-VFR Mini-Horn/Strobe Wheelock MIZ-24-HSW-HFR Mini-Horn/Strobe Wheelock MIZ-24-IS-VFR Mini-Horn/Strobe Wheelock MIZ-24-WS-VF-R Mini-HorrdStrobe Wheelock MIZ-24-Ws -VF-W Mini -Horn/Strobe Wheel'ock MIZ-24-WH-VF-W Mini-Horn/Strobe Wheelock MIZ-24-WM-VF-W Mini-Horn/Strobe Wheelock MT- 12/24-R Strobe Horn Wheelock MT224-LS-VFR Strobe Horn Wheelock MT-24-LSM-VFR Strobe Horn wheelock MT-24-MS-VFR Strobe Horn Wheelock M~'-24-IS-VFR Strobe Horn Wheelock MT-24-SL-V~'R Strobe Horn Wheelock MT-24-SLM-VFR Synch. Multitone Strobe Wheelock 'MT-24-WM ' ~ Strobe Wheelock MT-24-WM-VF-R Horn · Wheelock MT-24-WM-VFl~ Horn Wheelock RS -2415 -HFR Strobe ' -Wheelock RSP-2415-VFR Strobe 'Wheelock RS~241575-V~R Strobe ' 'Wheelock RSP-241575-VFR Strobe 'Wheelock RS-2430-VFR Strobe rWheelock RS-2430-HFR Strobe Wheelock RS-2475-VFR Strobe Wheelock RSP-2475-HFR Strobe Wheelock RS-24110-HFR Strobe Wheelock RSP-241 1 0-HFR Strobe Wheelock SL-24-VFR Synchronized Remote Sirobe 150865 A- 7 , Model 5207 Fire Control/Communicator Installation and Operation Manual Manufacturer Model Type Wheelock SL1-24-VFR Synchronized Remote Strobe · ~fheelock SL3-24-VFR Synchronized Remote Strobe Wheelock SLP-24-VFR Synchronized Remote Strobe Wheelock SLM-24-VFR Synchronized Remote Strobe Wheelock SL1M-24-VFR Synchronized Remote Strobe Wheelock SL3M-24-VFR Synchronized Remote Strobe Wheelock SLPM-24-VFR Synchronized Remote Strobe Wheelock SHW-24-VFR Synchronized Remote Strobe Wheelock SH2W-24-VFR Synchronized Remote Strobe Wheelock SHPW-24-VFR Synchronized Remote Strobe Wheelock SCM-24-R Controller for Synchronized Strobes Wheelock SM- 12/24-R Sync Module Wheelock SR-2415-VFR Sync Strobe Wheelock SRP-2415-HFR Sync Strobe Wheelock SR-241575-VFR Sync Strobe Wheelock SRP-241575~VFR Sync Strobe Wheelock SR-2475-VFR Sync Strobe Wheelock SR-2475-HFR Sync Strobe Wheelock SR-24110-HFR Sync Strobe Wheelock SRP-24110-HFR Sync Strobe Wheelock V700 IT- 12\24-W-FR Strobe Horn Wheelock WM3T-24-FR Remote Strobe Wheelock WM3T-24-VFR Remote Strobe Wheelock WS 1T-24-FR Strobe "' Wheelock WS3T-24-FR Strobe Wheelock WST-24-FR Strobe A-8 150865 ' Technical Service Note Product: DS250, DS260 and DS282 Two-Wire Smoke Detectors Detection Systems, Inc. Effects: Two-Wire Smoke Detector Control Panel 130 Perinton Parkway Fairport, NY 14450 Compatibility (800) 289-0096 (716) 223-4060 Fax (716) 223-9180 Date: December 1, 1998 I Disclaimer Notice: Detection Systems, Inc. makes no claims either written, oral, or implied that 2-Wire I tdetectors will work with any 2-Wire control panels except those listed in the following compatibility chad. The following is a list of 2-Wire control panels that are compatible with DS250, DS260 and DS282 Series Smoke Detectors. Manufacturer Model Zone Module Maximum Panel Manufacturer's Detectors per Compatibility Identifier Zone '-~eteciion Systems, Inc. DS7400/7400X/7400Xi N/A 20 B Detection Systems, Inc. DS7400/7400X/7400Xi DS7433 20 B Detection Systems, Inc. DS7100 N/A 20 B Detection Systems, Inc. DS7100 DS7110 20 B1 Detection Systems, Inc. DS7090/DS7090TM N/A 20 B Detection Systems, !nc. DS7090i/DS7090TMi N/A. 20 B Detection Systems, Inc. DS7080i N/A 20 B Detection Systems, Inc. DS9400 N/A 20 B Detection S~/stems, Inc., DS9400 DS9434 20 B Ademco 4140XMP N/A 15 A Ademco 4140XMPT N/A 15 A Ademco 5140XM N/A 15 A Ademco Vista-50P N/A 20 B Ademco Vista- 100 N/A 20 B Advantor ULF-3000-24 N/A 10 ULF1 CaddX NX8 Smoke 20 3800-0001 CaddX 8600E Smoke 20 3800-0001 Digital Monitoring Products 1812 Series 705 10 C1-1 Digital Monitoring Products 1912 705 10 C1-1 Digital Monitoring Products 1512 705 10 C1-1 Digital Monitoring Products 19.12XR N/A 10 A Digital Monitoring Products 1512, 1912, 1912XR 715 10 A Digita~ Monitoring Products XR 10 10 10 A Digital Monitoring Products XR20 715, Zone 10 10 A Digital Monitoring Products XR200 715, Zone 9 or 10 10 A Digital Monitoring Products XR5FC 2 -5 10 A Digital Security Controls P16128CF PC4701 or P4701 30 FM-2 Digita! Security Controls PC1555 N/A 10 PC15-1 Digital Security Controls PC1565 N/A 10 PC15-1 Digital Security Controls PC4010CF PC4701 or P4701 30 FM-2 Digital Security Controls PC5008 N/A 10 PC15-1 Digital Secudty Controls P6B N/A 10 PC15-1 Digital Security Controls PC5010 N/A 30 PC5-1 Digital Security Controls P832 N/A 30 PC5-1 Digital Security Controls P864CF PC4701 or P4701 30 FM-2 Faraday 19000A/EVAC 401126,401127 20 B Faraday MPC2000 401310, 401311, 30 D, 401312 Faraday 15108B/BL N/A 15 NFOS2 Faraday 15112B/BL N/A 15 A/FOS2 Faraday 15116B/BL N/A 15 NFOS2 Faraday 15220 N/A 30 C Faraday 15240 N/A 30 C Faraday 852 N/A 30 FOS1 Faraday 854 N/A 30 FOS1 FCI FC-72 ZDM 25 ZDM01 Fire-Lite Audio EVAC 1/2 ZAB 6 A Fire-Lite MP-12 N/A 10 A Fire-Lite MP-24 N/A 10 A Fire-LitE MS-124 N/A 10 A P/N 26979L Copyright © 1996-98 Detection Systems, Inc. Page 1 of 2 Manufacturer Model Zone Module Maximum Panel Manufacturer's Detectors Compatibility Identifier per Zone Fire-Lite MS424A ANC-2B, WFC, 15 A CVC-2 Fire-Lite MS4012 N/A 10 A Fire-Lite MS4024 N/A 10 A Fire-Lite MS4824 IZ424 20 A Fire-Lite MS5210UD N/A 25 B Fire-Lite MS4424B N/A 24 B Fire-Lite MS4412B N/A 24 B Fire-Lite MS-5024 N/A 25 A Fire-Lite SePsis'can 2000 ANC-2B, WFC, 15 A CVC-2 First A~ert FA1200C N/A 15 A First Alert FA1300C N/A 15 A First Alert FA1500C N/A 15 A Honeywell 5501 N/A 10 "B Honeywell 5503 N/A 10 B Honexwell 5700 N/A 10 A Honeywell 5800 D 125B 10 D125B Honeywell 5505 D125 10 A Honeywell 5900 D125B 10 D125B Napco MFA6024 MFA6024 30 ! MF24A Naj:)co MA1010LKDL MA1010LRDL 10 MA 1010 Napco GEM-P3200 2-wire 40 Z7/Z8 Napco GEM-P1632 2-wire 40 Z7/Z8 Potter PFC-100 N/A 25 A Potter PFC-100R N/A 25 A Potter P FC-2000R N/A 25 A Potter PFC-2000RC N/A 25 A Radionics D2112 N/A '" 12 E~ ...... Radionics D2212 N/A 12 B Radionics D4112 N/A 10 B Radionics D6112 N/A 10 B Radionics D7024 N/A 20 B Radionics D7024 D7034 20 E~ Radionics D7112 N/A 10 A Radionics D7212, 7412 D 125B 10 D125B Radionics D8112 D125 10 A Radionics D9112,9412 D 125B 10 D 125B Silent Knight 5204 (24 volt) N/A 18 24C Silent Knight 5204 (12 volt) N/A 13 12C Silent K.r?ght 5207 (24 volt) N/A 18 24D Silent Knight 5207 (12 volt) N/A 13 12D Silent Knight 5207 (24 volt) 5210 8 24A .i Silent Knight 5207 (12 volt) 5210 8 12A Silent Knight 5204, 5207 (24 voit) 7181 8 . ._ 13 Silent Knight ..... :4720,'520~-,-5207 (12-voltI 7181 8 B Thorne K 101-24 N/A 30 10124A Westec MS5000 MS5005 5 W P/N 26979L Copyright © 1996-98 Detection Systems, Inc. Page 2 of 2 · security_ --svstems;[nc.~ - .. .. ' -' ' ~ .. " .. QUality in Security, QUality.in Service ' , .... '.' .. December 1, 2000 Pr°ject. m ' .. Sandstone Charter School · East 18th Street Bakersfield, CA 93301 Owner Kern CoUnty SuI }erintendent Of Schools ' :. · - 1300- 17th' Street TM City ,Centre. . . Bakersfield~ CA 93301-4533 Ph# (661) 636-4700 Fax# (661) 636~4201 ... ' " Contact: 'Jenny Hanna - .. Contractor . TeI?Te.c Security'Systems, Inc. · ' 5020 Lisa'MarieCourt ..... : i ~i' . Bakersfield, CA .93313 . Ph#'(661) 397-55!1 Fax#-(661)834-3616 .' · =..- -:.i..,- i /' i ",Contact: Mo.rgan E' Clayton . ' 39 51 : 5020 Lisa Marie Court .. Bakersfield,.CaEfomia 93313 · (661) SILENT COMMERCIAL FIRE ALARMS FEATURES: · Eight zones, 6 Style A (class B) and 2 Style D (class A). 8 Expander Zones are Style A (class B). Zones are interchangeable using the Model 7181 Zone Converter. · UL, FM, MEA (BSA), CFM Listed and Approved. · Event memory. · Fuseless design can reduce service time. · Field selectable, 12 or 24 VDC power supply. ·Six amp current output at 12 volts, five amps at 24 volts. · Compatible with 2- and 4- wire smoke detectors as well as water flow and sounding devices. · ANSI Cadence Pattern Output. · Four programmable (Style Y) supervised signal '.. circuits, including steady, pulse and temporal. · Programmable smoke verification, pre-alarm delay, and cross-zoning can minimize false alarms. · Four general purpose relays (Form C 24 volts at 2.5 5207 amps resistive). - · Built-in approved cl. igital communicator with UL required priorty repOrting. · Flexible programming capabiities including up/ or system problems, exist. If the 5207 encounters a fire downloading and use of remote annunciator. No or trouble condition, it sends a report to a central "desktop" programmer required, monitoring station (if applicable), and, typically, sounds an audible/visual warning in the local area. · Accu-Zone® diagnostics facilitate local and remote troubleshooting. The 5207's microprocessor constantly runs programs to · Individual zone Walk Test. check inputs and carry out other routine functions. If the program ever stops running, a watchdog circuit will detect it and reset microprocessors to resume normal DESCRIPTION: operations. The Model 5207 is an all-in-one fuseless local fire evacuation control panel and digital The Model 5207 conducts an automatic self-test every. 24 hours--at a time you select--and sends a report to communicator designed for applications requiring manual fire alarm, automatic fire alarm and water flow the central station (if applicable). for sprinkler system supervision. The basic unit offers fire alarm for one to eight zones, expandable to 16 with Other features of the system include English-language the optional 5210 expansion module. It is compatible remote annunciation simplifying "Step Programming" of with bothtwo-andfour-wiresmokedetectors. Compact, custom options. Remote downloading of system configurations can eliminate the expense of sending out easy to install and service, it delivers the features you'd aservicetechnician for reprogramming. System provides expect to find in fire systems costing much more. a built-in fire drill procedure. The exclusive Accu-Zone® During normal operation, the 5207 constantly checks feature measures and displays zone voltages, so you smoke and other sensing devices for fire conditions. It can set up and test the system without separate testing also conducts system checks to determine if anytroubles, equipment. Fuseless circuit board design eliminates one of the most likely causes for service calls. PROGRAMMING ANNUNCIATION The 5207 includes an annunciator inside the cabinet. Its six LEDs (for alarm, trouble, silenced, AC/Iow battery, event memory, time set/reporting) are visible without opening the cabinet. The annunciator allows for easy operation of all functions. It features dual seven-segment display and 14 uniquely assigned function keys. Keys are: ENTER, CLEAR, SILENCE, SHUNT and 0-9 used for ALARM RESET, CLEAR ALARM MEMORY, DIALER RESET, REQUEST DOWNLOAD, DISPLAY MEMORY, TEST, DISPLAY TROUBLES, SET DATE and SET TIME. Remote annunciation is available through the Model .- . 5230. This four-wire, 16-zone remote annunciator is ¥--~ , "~ easy to operate. Its fourteen function keys can perform 5521 the same operations as the main system annunciator, including silencing, resetting, and displaying of alarms, On-site programming is available through the optional troubles and alarm memory. Use of access codes Model 5521 Desktop Programmer or through any remote annunciator, prevents unwanted tampering. In addition the Model 5230 can be used to program all programmable options Remote programming can be accomplished through the for both the local control and digital communicator. use of 5521 programmer and 5530 modem, or through the use of an IBM or compatible personal computer and Features include LCD display, backlighting, English- the Model 5541 Downloading Software (requires the language annunciation. Model 5530 Downloading Modem). Up to seven 5230s can be attached to one 5207. Standby More than 60 programmable options are available for current draw per 5230 is 60 mA, alarm current is ~120 mA. customizing system configurations and end-user features, including zone type (fire, panic, tamper, sprinkler, water, heat, cold, local); zone options (pre- i: ~J a~arm delayed, smoke verification delayed, zone disable); = ~ i and zone location descriptions. Programmable dialer ; options include total number of reporting attempts, Touch- Tone® or rotary dialing, one or two telephone lines. ;~ . . F,,~ALA,, Several time delay features, including number of seconds to alarm in pre-alarm, smoke delay conditions, number .': ...... of hours before loss of AC hours report, and 24-hour test -- 'L,~I~,~'L'~," ~ :I time, can be programmed, ii ii i i 'lii ZONE EXPANSION ...................................................... .'..- '-.' ............ The optional Model 5210 Zone Expander doubles the 5230 number of zones available to the 5207 from 8 to 16. The 5210 adds eight additional style A (class B) zones to the 5207, enabling use of both two- and four-wire COMMUNICATIONS/REPORTING smoke detectors. The 5207 is equipped with a UL listed digital dialer Voltage Ranges: Using 24-VDC power: 17.8-27.4VDC. which has the ability to seize the telephone line(s) to Using 12-VDC power: 8.5-11.8 VDC. report alarms and troubles to a central station. It can supervise the telephone lines and activate a trouble- alert if a line failure is sustained for 45 seconds or longer. Other communications/reporting features include: Built- in ring detector; re-try if communication failed; fail-to communicate output; one or two phone lines option; up to four phone number capability (plus computer phone for downloading); Touch-Tone® and rotary comgat[bte. '~. The 5207 is compatible With all major reporting formats including SIA (security industry standard), SK, 5210 FSK, SK 4/2, Radionics BFSK. Format selectable by account number. SPECIFICATIONS Model 7181 Fire Zone Convertor ELECTRICAL SPECIFICATIONS: Converts Style A zones to Style D and vice versa. · Primary AC: 120 VRMS at 60 HZ, 2A · Total Accessory Load: 5A at 24 VDC ...... 6A at 12MDC INDICATOR LIGHTS: · AC/DC POWER (Green) - On when system is running on AC power; flashes when using DC. · ALARM (Red) - On for supervisory alarm; flashes for 5220 Direct Connect Module fire alarm. Used for City Box and polarity reversing direct · TROUBLE (Yellow) - On when trouble condition exists. wire applications. · SILENCED (Yellow) - On when alarm or trouble has been silenced but not yet cleared. · EVENT MEMORY (Yellow) - On when an alarm condition has been reset. · SET MODE/REPORT (Yellow) - On when system is in test or program mode, including Date/Time set mode. Flashes when system is reporting. 5530 Downloading Modem MECHANICAL SPECIFICATIONS: SIA format modem for remote programming of 5207. · Dimensions: 16 in. W x 26.4 in. H x 4 in. D (40.6cm W x 67cm H x 10.2cm D) · Weight: 25 lbs. (11.4 kg.) ~~ _ · Color: Red i ..... '~" TELEPHONE REQUIREMENTS: · FCC Registration No.: AC6USA-65475-AL-E .. · Type of Jack: RJ31X (2 required) APPROVALS: 5541 'Downloading Software · UL Listed For remote programming with IBM PC and compatible · FM Approved computers. Can be used with 5207. Requires 5530 · CFM Approved modem. Software/modem package may be ordered · New York City MEA (formerly BSA) as a 5561. · NFPA - Central Station Reporting - Local Protective Signaling System - City Box - Polarity Reversal - Proprietary Protective Signaling System 5260 Printer Interface OPTIONALACCESSORIES ^,ows connection of a standard computer printer to Model 4180 Status Display Module provide a printed record of 5207 system activity. Simple Provides 16 outputs to give alarm and trouble conditions plug-in connection. (Printer not supplied.) by zone. Two units can be connected t(~ annunciate all 16 zones on a 5207 control. Can be used to drive LED or graphic annunciators. (Non-supervised) ARCHITECT/ENGINEER SPECIFICATIONS The contractocshall provide acomplete electrically supervised shall be programmed to operate on (1) pre-alarm, (2) tamper fire alarm and ~communications system. The system shall alarm, (3) special alarm, (4) fire alarm, (5) trouble, (6) no- contain a fire alarm control/communicator and panel to silence, (7) alarm by specific zone (1-16). The relays shall supervise and operate heat and smoke detection devices, remain energized until the panel is silence reset or the trouble t~' alarm signal devices, visual annunciators and an integral condition is cleared, unless "no-silence" is selected. digital communicator to transmit fire alarm and supervisory signals to a central station. The control/communicator shall be The control/communicator shall have an integral annunciator UL Listed or FM approved for use under NFPA 71,72A, 72B, to indicate sequentially zones in alarm, zones in trouble, and 72C and 72D standards. It shall provide power and control for system functions. LEDs shall augment the display to make eightsupervised detection zones,~ursupervised alarm signal clear to an operator the system status. An integral touchpad circuits and a dual digital communicator. The control/ shall be provided to operate, set up, and interrogate the communicator shall be expandable to sixteen supervised system. Vital operations such as alarm silencing or reset shall detection zones and shall be able to communicate to a central be simple and obvious to an operator. Authorization pass station in SIA, SK FSK1, SK 4/2 or Radionics BFSK formats, codes may or may not be used. The control/communicator shall be Model 5207 or approved equal. The control/communicator shall have the capability to supervise two telephone lines, seize the phone line, and send the alarm There shall be two Style D and six Style A detection zones, signal on one or both lines without the addition of any more They shall accommodate heat detectors, products of equipment. Itshallsoundalocaltroublesignalifthetelephone combustion detectors, manual pull stations, sprinkler flow service is interrupted for longer that 45 seconds and it shall switches and gate valve supervisory switches intermixed as transmit a signal indicating the loss of phone line service to the desired and permitted by NFPA 71,72A, 72B, 72C, and 72D. central station over the remaining phone line. A signal shall Products of combustion detection may be either two- or four- also be transmitted indicating the restoral of phone service. wire and shall be cross listed by UL for use on the system. The The control/communicator shall be able to report the loss of detection zones shall be programmed to (1) be cross zor~ed so either phone line without regard to which phone line failed first. · that two individual zones must sense products of combustion, If both lines fail, a local signal shall sound. (2) automatically reset a detector to verify that smoke exists, (3) see a single detector in alarm--before the alarm is sounded The control/communicator shall have the ability to send a test and a signal is transmitted to the central station, signal to the central station every 24 hours. The test signal shall be able to be transmitted at a specific time of day or night There shall be four I amp supervised (Style Y) alarm signal by setting a program within the panel. circuits. They shall cause the bells/horns to ring steady/ pulsing/temporal throughout the premises until reset or The alarm signals transmitted to the central station shall silenced. Two I amp outputs can be combined to provide one indicate which of the eight zones is in alarm and which zones ,, 2 amp output, are in trouble, depending on which format is used. Restoral from alarm or trouble shall also be transmitted by zone. The The control shall be equipped with four auxiliary relays that · control/communicator shall be capable of communicating to Silent Knight, Radionics or Ademco central station receivers. MODEL 5207 BLOCK DIAGRAM - TYPICAL INSTALLATION SILENT 7550 Meridian Circle, Maple Grove, MN 55369-4927 1-800-446-6444 or in Minnesota (612) 493-6435 MADE IN ~GHT FAX: (612)493-6475 AMERICA FIRE SYSTEMS® Form #150376 (Rev 9/96) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE ' LISTING No: 7165-0559:111 Page 1 of 1 CATEGORY: Control Units (Non High-Rise) LISTEE: Si{ant Knight, 7550 Meridian Circle, Maple Grove MN 55369-4927 Contact: Brian Foltz *(763) 493-6400 DESIGN: Model 5207. Local or central station service; poWer-limited. Refer to listee's data sheet for detailed product description and operational considerations. Basic local system: 5207 Control Unit 5197 Power Supply 7628 EOL Resistor 204A/204C Power Supervision Unit (or Pyrotector 2040-xx) OPTIONS: Refer to listee's data sheet for required/optional accessories. When required, accessories shall be CSFM listed. Accessories included with this listing: 4180 Status Display Module 5210 Zone Expander Module 7171 Loop Module 5230 Remote Keystation INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: I istee's name, model number and CSFM label. APPROVAL: Listed as a control unit for use with separately listed compatible initiating and indicating devices. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1993 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. *Rev. 06-21-2000  This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to vedfy correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: J U N E 21~ 2000 Authorized By: Effective issue date to expiration date it Listing Expires June 30, 2001 Program Manager Models Available* Horn/Strobes P1215 P121575 P2415 P241575 P2430 P2475 P24110 Strobes S1215 S121575 S2415 S241575 S2430 S2475 S24110 Horns H12/24 * Refer to Ordering Information for other configurations Product Overview Meet UL and ADA signaling requirements System Sensor's SpectrAlert wal-mount series includes a complete line of electronic horns, strobes, and horn/strobes. Intended for primary signaling use, SpectrAlert Low current draw products meet UL1971, UL464, and Americans with Disabilities Act requirements. More devices per loop Lower installed cost Performance. With its extremely efficient reflector design and Xenon flash tube, Universal mounting plate included SpectrAlert offers current draw reductions as high as 40% over previous gener- ation designs. By consuming less current, the flexibility to connect more devices Accessory mounting plates available per loop is possible, for a lower installed cost. Field-selectable horn tones Installation. SpectrAlert products offer installation ease which also lowers the Electromechanical / 3kHz installed cost. By taking up no room in the back box. SpectrAlert strobes and Temporal 3 / Non-temporal 3 horn/strobes make wiring connections simpler and faster. Each SpectrAlert High / Low dBA output includes a universal mounting plate for 4"square and single gang back box Available in 15, 15/75, 30, 75, and 110 mounting. Accessory mounting plates are also available for small footprint or surface mount applications. candela Flexibility. SpectrAlert offers the flexibility to rneet a broad range of Synchronizable horns and strobes with requirements. The SpectrAlert horns and horn/strobes feature a number of Sync.CircuitTM module field-selectable/reversible horn tones. For visible requirements, SpectrAlert Aesthetic design strobes and horrdstrobes are available in a wide variety of configurations to address non-sleeping area, sleeping area, and corridor requirements. Offerings include 24-volt models at 15, 15/75, 30, 75, and 110 candela, and 12-volt devices at 15 and 15/75 candela. MEA incorporates a stylish, Iow profile design. And this aesthetic is consistent across approved all SpectrAlert wall-mount products. Engineering Specifications General Horn/Strobe CombinaUon SpectrAlert horns, strobes and horn/strobes shall be capable Horn/Strobe shall be a System Sensor SpectrAlert Model of mounting to a standard 4" x 4"x ll/z" back box or a -- listed to UL 1971 and UL 464 and shall be single gang 2" x 4" x 17/8.. back box using the universal approved for fire protective service. Horn/strobe shall mounting plate included with each SpectrAlert product, be wired as a primary signaling notification appliance Also, SpectrAlert products, when used in conjuction with and comply with the Americans with Disabilities Act the accessory, Sync.Circuit Module, shall be powered requirements' for visible signaling appliances, flashing at from a non-coded power supply and shall operate on 12 IHz over the strobe's entire operating voltage range. or 24 volts. 12 volt rated devices shall have an operating The strobe light shall consist of a xenon flash tube and voltage range of 10.7-17 volts. 24-volt rated devices associated lens/reflector system. The horn shall have two shall have an operating voltage range or 20-30 volts, tone options, two audibility options (at 24 volts) and the SpectrAlert products shall have an operating temperature option to switch between a temporal 3 pattern and a of 32° to 120°F and operate from a regulated DC or full non-temporal continuous pattern. Strobes shall be powered wave rectified, unfiltered power supply, independently of the sounder with the. removal of factory installed jumper wires. The horn on horn/strobe models Horn shall operate on a coded or non-coded power supply Horn shall be a System Sensor SpectrAlert Model ~ (the strobe must be powered continuously). capable of operating at 12 and 24 volts. Horn shall be listed to UL 464 for fire protective signaling systems. The Synchronization Module horn shall have two tone options, two audibility options Module shall be a System Sensor Sync.Circuit __ (at 24 volts) and the option to switch between a temporal listed to UL 464 and shall be approved for fire protective 3 pattern and a non-te}nporal continuous pattern. All horn service. The module shall synchronize SpectrAlert strobes models shall operate on a coded power supply, at 1Hz and horns at temporal 3. Also, the module shall silence the horns on horn/strobe models, while operating Strobe the strobes, over a single pair of wires. The module shall Strobe shall be a System Sensor SpectrAlert Model __ be capable of mounting to a 4~i/1~'' x 4~V~"x 21/8TM back listed to UL 1971 and be approved for fire protective box and shall control two Style Y (class B) or one Style Z service. The strobe shall be wired as a primary signaling (class A) circuit. Module shall be capable of multiple zone notification appliance and comply with the Americans with synchronization by daisy chaining multiple modules Disabilities Act requirements for visible signaling appli- together and re-synchronizing each other along the chain. ances, flashing at 1Hz over the strobe's entire operating The module shall not operate on a coded power supply. voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Specifications Walk Test SpectrAlert horn/strobe and horn only Weight, horn only Weatherproof (horn and horn/strobes) work on "walk tests" witl~ time durations of 7.2 oz. Operating Temperature 4 seconds or greater Weight, strobe and I~orn/strobe 32°F to 150'F (O'C to 66°C) input Terminals 8.8 oz. (outdoor strobe only) -40°F to 158°F (-40°C to 70°C) 12 to 18 AWG Mounting ULC Canadian Models Dimensions 4" x 4" x lZ/2" or 2" x 4" x l~s" -40'C to 66°C Stroi~e and horn/strobe with universal [)late standard boxes Voltages 5" x 5~'a" x 2~'~s" Indoor Operating Temperature 12 or 24VDC and FWR unfiltered Strobe and horn/strobe with small 32°F to 120"F (O"C to 49°C) Operating voltage range* footprint plate 33/8~ x 5~/s" x 25/~6" Maximum humidity 12V: 10.5-17V; 24V: 20-30V Horn with universal mounting plate 95% as tested per UL464 Operating voltage range* 5" x 55/a'' x 15/~a" (with Sync-Circuit module, MDL) Hort1 without mounting plate 12V, 11-17V; 24V, 20-30V 2~/xa" x 5~/xa" x 15/16" * These products should be operated within their rated voltage range; UL does, however, test functional integrity to -20% and +10% of manufacturer's stated ranges. U.S. Patent Numbers 5,593,569 5,914,665 6,049,446 SpectrAlert Current Draw Table Strobe Only Average Current (mA) Peak Current (mA) In Rush Current (mA) 12V Models 24V Models 12V Models 24V Models 12v Models 24V Models 10.5V 12V. :/TV 20V 24V 30V 10.5V I 12V 17V 20V 24V 30V 10.5V 12V 17v 20V 24V I 30V Candela I Dc FWR OC FWR DC FWR DC FWR DC !FWR DC FWR DC FWF DC FWR DC iFWR OC FWR OC FWR DC FWR DC FWF DC FWF OC FWR DC FWR DC FWR DC FWR 15 133 159 114 157 81 3-28 50 6;1 43 60 38 60 460 460 450 460 420 480 3.35 204 135 208 3.35 185 80 108 92 I24 140 190 97 129 3.16 152 147 3.98 ~.5/75 168 3.82 142 173. 99 150 56 65 49 64 44 62 490 520 490 520 460 480 3.50 199 150 207 150 198 76 3,04 88 126 160 3,85 97 135 13.6 164 3.47 23,3. 30 NA NA NA NA NA NA 78 84 67 82 58 72 NA NA NA NA NA NA 183 201 183 23,9 183 216 NA NA NA NA NA NA 97 129 116 3.52 147 198 75 NA NA NA NA NA NA 145 3,7O 123 159 3.O2 141 NA NA NA NA NA NA 350 440 34O 460 330 480 NA NA NA NA NA NA 190 240 23O 28O 29O 380 I_10 NA NA NA NA NA NA 169 i 220 3.40 191 3,15 3.74 NA NA NA NA NA NA 460 560 450 570 420 620 NA NA NA NA NA NA 190 230 220 290 290 370 Horn Only Horn/Strobe 30 cd Average Current (mA) Average Current (mA) 12V Models 24V Models 24V Models High/Low Temp/ 10.5V 12V 17V 20V 24V 30V High/Low Temp/ 20V 24V 30V Forte Volume Non DC FVVR DC FWR DC FWR DC FWR DC ;WR DC -~VR Tone Volume Non DC FWR DC FWR DC FWR -'lectro- High Temp 10 11 10 10 14 14 19 21 25 18 29 26 Electro- High Temp 97 105 92 100 87 98 nech. Non 10 16 10 19 '~4 25 17 29 23 34 30 42 mech. Non 95 113 90 116 88 114 Low Temp NA NA NA NA NA NA :/l 12 13 13 17 15 Low Temp 89 96 80 95 75 87 Non NA NA NA NA NA NA 12 16 14 19 17 24 Non 90 98 81 101 75 96 3000 Hz High Temp 11 13 11 11 16 16 24 26 28 23 37 33 3000 Hz High Temp 102 108 95 105 95 :/05 nterrupt. Non 11 17 11 21 14 28 19 34 27 39 35 45 interrupt. Non 97 116 94 121 93 117 Low Temp NA NA NA NA NA NA 14 14 17 15 21 19 Low Temp 92 96 84 97 79 91 Non NA NA NA NA NA NA 13 18 16 21 22 25 Non 91 100 83 103 80 97 Horn/Strobe 15 cd Horn/Strobe 75 cd Average Current (inA) Average Curren~ (INA) 12V Models 24V Models 24V Mo~els High/Low Temp/ 1.0,5V 12V 17V 20V 24V 30V High/Low Temp/ 20V 24V 30V reno Volume Non DC FWR DC FWR DC FWR DC FWR DC IFWR DC FWR Forte Volume Non DC FWR OC FWR DC FW~ Electro- High Temp 143 170 124 167 95 142 69 82 68 78 67 87 [lectro- High Temp 164 191 148 167 131 167 ~ech. Non 3.43 170 124 167 95 142 67 90 6694 68 103 nech. Non 163 188 146 169 132 16.c Low Temp NA NA NA NA NA NA 61 73 56 73 55 76 Low Temp 156 182 136 162 119 15~ Non iNA NA NA NA NA NA 62 77 57 79 55 85 Non 157 182 137 162 119 157 3000 Hz High Temp 144 172 125 168 97 144 74 87 71 83 75 94 ~000 Hz High Temp 169 :/96 151 172 139 nterrupt. Non 3.44 173 125 168 95 146 69 95 70 99 73 106 nterrupt. Non 164 192 150 175 137 177 Low Temp NA NA NA NA NA NA 64 75 60 75 59 80 Low Temp 159 184 140 164 123 16(: Non NA NA NA NA NA NA 63 79 59 8:/ 60 86 Non 158 188 139 163 124 16~ Horn/Strobe 1575 cd Horn/Strobe 110 cd Average Current (INA) Average Current (mA} 12V Models 24V Models 24V Models High/Low Temp/ 10.5V 12V 17V 20V 24V 30V High/Low Temp/ 20V 24V 30V fone Volume. Non DC FWR DC FWR DC FWR DC FWR DC FWR DC -'WR ~on~ Volume Non DC FWR DC FWR DC FWR -'lectro- High Temp :/78 193 152 181 113 164 75 86 74 82 73 88 -'lectro- High Temp 188 241 165 209144 200 nech. Non 3.78 193 152 181 113 164 73 94 72 98 74 104 nech. Non 186 238 163 211 145! 202 Low Temp NA NA NA NA NA NA 67 77 62 77 61 77 Low Temp 180 232 153 204 132 189 Non , NA NA NA NA NA NA 68 81 63 83 61 86 Non 181 232 154 204 132 19Q 3000 Hz High Temp 179 195 152 183 :/15 166 80 9:/ 77 87 81 95 3000 Hz High Temp 193 246 :/68 214 [52 207 nterrupt. Non 179 196 152 183 113 168 75 99 76 103 79 :/07 nterrupt. Non :/88 242 167 217 :/50 210 Low Temp NA NA NA NA NA NA 70 79 66 79- 65 81 Low Temp 183 234 157 206 136 193 Non NA NA NA NA NA NA 69 83 65 85 66 87 Non 182 232 156 205 137 195 Sound Output Guide (dBA) UL Reverberant Room dBA @ volts DC Anechoic Room Peak dBA @ 3.0ff./volts DC 3.0.5 3.2 3.7 20 24 30 3.0.5 3.2 3.7 20 24 30 I'emporal Low Tone Electromechanical NA NA NA 75 75 79 NA NA NA 94 ,96 98 3000 HZ Interrupted NA NA NA 75 79 79 NA NA NA 94 96 98 High Tone Electromechanical 75 75 79 82 82 82 94 95 98 100 101 :LO2 3000 HZ Interrupted 75 75 79 82 85 85 94 95 98 100 101 102 ~omTemporal Low Tone. Electromechanical NA NA NA 79 82 85 NA NA NA 94 96 98, 3000 HZ Interrupted NA NA NA 82 82 85 NA NA NA ! 94 96 98 High Tone Electromechanical 79 79 85 85 88 88 94 95 98 100 101 102 3000 HZ Interrupted 79 82 85 88 88 88 93 95 98 100 101 102 SpectrAlert Ordering Information Avg. mA* Avg. mA* Red White Voltage Candela @Nom. VDC @Nom. FWR** Horn/St robes P 1215 P 1215W 12 15 124 167 Pi21575 P123.575W 12 15/75 152 181 ~ P2415 P2415W 24 15 68 78 P241575 P241575W 24 15/75 74 82 P2430 P2430W 24 30 92 100 P2475 P2475W 24 75 148 '[67 ,~24110 P24110W 24 110 165 209 P121575K (weatherproof) -- 12 15/75 124 167 P241575K (weatherproof) -- 24 15/75 74 82 P2475K (weatherproof) -- 24 75 148 167 P24110K (weatherproof) -- 24 :110 165 209 P241575P (no lettering) P241575PW 24 15/75 74 82 P241575AG (AGENT) -- 24 15/75 74 82 P241575EV (EVAC) -- 24 15/75 74 82 Canada P2415A P2415WA 24 15 68 78 P241575A P243.575WA 24 15/75 74 82 P2475A P2475WA 24 75 148 167 P 24110A P 24110WA 24 110 165 209 P241575KA (weatherproof) -- 24 15/75 74 82 P2475KA (weatherproof) -- 24 75 148 167 P24110KA (weatherproof) -- 24 110 165 209 Latin America P241575F (FUEGO) -- 24 15/75 74 82 Strobes S1215 S1215W 12 15 114 157 S121575 S121575W 12 15/75 142 171 S2415 S2415W 24 15 43 60 S241575 S241575W 24 15/75 49 64 S2430 S2430W 24 30 67 82 S2475 S2475W 24 75 123 159 S24110 S24110W 24 110 140 191 S121575K (weatherproof) -- 12 15/75 142 171 S241575K (weatherproof) -- 24 15/75 49 64 S2475K (weatherproof) -- 24 75 123 159 S24110K (weatherproof) -- 24 110 140 191 S241575P.(no lettering) S241575PW 24 15/75 49 64 S241575AG (AGENT) -- 24 15/75 49 64 S241575EV (EVAC) -- 24 15/75 49 64 Canada S2415A S2415WA 24 15 43 60 S241575A S241575WA 24 i5/75 49 64 S2475A S2475WA 24 75 123 149 S24110A S24110WA 24 110 140 191 -' S241575KA (weatherproof) -- 24 15/75 49 64 S2475KA (weatherproof) -- 24 75 123 149 S24110KA (weatherproof) -- 24 110 140 191 Latin America S241575F (FUEGO) -- 24 15/75 49 64 Horns H12/24 H12/24W 12/24 NA 10/25 :10/18 H 12/24K (weatherproof) -- 12/24 NA 10/25 10/18 Canada HC 12/24A HC 12/24WA 12/24 NA 10/25 3.0/18 HC 12/24KA -- 12/24 NA 10/25 10/18 Sync · Circ uit M DL M DLW 12/24 NA 10/11 12/15 Module Canada M DLA 'M DLWA 12/24 NA 10/11 12/15 Small Footprint Mounting Plate for Single Gang Only S-MP S-MPW NA NA NA NA Surface Mount Back Box Skirt BBS BBSW NA NA NA NA Universal Mounting Plate (replacement) D-M P D-M PW NA NA NA NA Weatherproof Back Box WBB -- NA NA NA NA Notes: Agency Listings- Indoor models: UL, ULC, FM, CSFM, MEA. Weather 3roof models: UL, CSFM (strobe only), MEA, ULC. All of these SpectrAlert products are designed for wall mount only. All weatherproof models must use weatherproof back box model WBB. Installation of less than 75 can- deta strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn/strobes are recommended for 20' x 20' rooms or less. · Horn and horn/strobe current draws assume horn is set at temp 3, electromechanical tone and high audibility. · * FWR = Full Wave Rectified System Sensor Sales and Service System Sensor Headquarters System Sensor In Canada System Sensor In Chtna System Sensor In the Far East System Sensor In India 3825 Ohio Avenue Ph: 905.812.0767 Ph: + 86.29.524.6253 Ph: + 852.21919003 Ph: + 91.11.558.2119 St. Charles, IL 60174 Fx: 905.812.077.1 Fx: + 86.29.524.6259 Fx: + 852.27366580 Fx: + 91.11.567.6815 Ph: 800-SENSOR2 Fx: 630/377-6495 System Sensor In Europe System Sensor In Singapore System Sensor In Australia Documents On Demand: Ph: + 44.1403.276500 Ph: + 65.273.2230 Ph: + 613.54.281,142 1~00-736-7672 x3 Fx: + 44,1403.276503. Fx: + 65.273.2610 Fx: + 613.54.281.172 Web: www.systemsensor, com ~ 1999 System Sensor. The company reserves the right to change proOuct specifications without notice. AOS-936*og.6/OO(lOK),#572 ~ ~(~,~ CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM Usting Expire~ June 30~ 2000 LISTING SERVICE LISTING No. 7135-1209:143 Page 1 of 1 CATEGORY: 'Audible Devices LISTEE: System Sensor, 3825 Ohio Avenue, St. Charles IL 60174 Contact: Adam Kozlowski (630) 377-6580 DESIGN: Models PA4OOR, PA4OOB, PA40OW, APA-451, H12/24, H12/24W, H12/24K*, HC 12/24, HC12/24W and HC12/24K* sounders. Suffix "W" indicating white color and suffix "K" indicating extended indoor operating temperature range of 32o F to 150o F and a NEMA 3R enclosure rating. Models H12/24, H12/24W, HC12/24, HC12/24K' and HC12/24W are not suitable for public mode fire alarm service when used at Iow volume on 12V control panels. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: PA Series: 1 2 or 30 VDC APA Series: 15 - 32 VDC H12/24 or HC 12/24 Series: 10.5 - 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: ~ Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. For indoor use only. *Series H12/24 and HC12124 can generate the Temporal Pattern signal. If series APA or PA are required to produce a distinctive three-pulse Teml~0ral Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1993 Edition, they must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's InstaIlation Manual for details. NOTE: Formerly 7135-0087:132 *Rev. 07-1 ~,o98  This listin$ is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct o~erafional requirements or installation criteria. Refer to listee's clara sheet, installation instructions and/or other suitable information sources. 3ate Issued: JULY 1, 1999 Authorized By: Effective issue date to expiration date ~ ~re Marshal II I Program Manager I I IIIIII III I I I II IIII Dieu ast Metal ', P I Stations Manual, ..' ~ .. -... ::..z--'.. ~~. ,.'~' '~3¢ Silent Knight die ca~ mdal manual ~,.:, :~_:~ ~.., pull smtions p~ quali~ and peace =--=:~¢,~,~:~.~;~.-~?,,*= ~ of mind in easy reach. A manual pull station doesn't have to be fancy ~ just tough, reliable and e~emely easy to operate. Silent Knighfs die cast metal pull stations are all ~ree. They're ~e high~uali~ choice for ~st, sure initiation of a fire alarm signal. Our manual pull stolons fea~re ~gged, die cast metal constru~ion Dst lasts and lasts. They're available in ~ingle or dual a~ion models. And Silent Knight manual pull stations are UL-Listed, CSFM Approved, and M~ (BSA) Approved. For outdoor use, a wea~erproof model is also available. On your ne~ job, make the high~uali~ choice - Silent Knight manual pull stations. For more information, or for additional info~ation on our complete fire products line, call Silent Knight today at 1-800~46-6d~4, or in Minneso~ call (612) 493-6~5. JII I I I II I I I I I I Die Cast Metal Manual Operation Pull Stations ~e single a~ion pull stolons a~ Silent Knight's new line of manual pull operated by simply pulling the handle on sta~ons feature high~uali~, die ca~t ~e ~nt of ~e s~don as ~r down a~ it metal consVu~on. They are available in will go, at which point the handle Iock~ either single or dual a~on conflgu~ons i~o place and i~ easily visible ~om up to wi~ SFS~ ~itch, and with ~ire lead or 50 feet. A scored ac~lic b~ak rod is al~o retinal s~p ~nne~ions, ~e normally supplied with each unit for applica~ons open con~, which closes ~hen ~e pull when that is necessary. ~e handle is sta~on is a~vated, is rated for I amp, at ~set by opening the station wffh the hex 12~AC, or 30VDC. ~e conta~s a~ wrench or key, placing the handle in gold-plated to avoid risk of co~osion. All the normal upright position and ~locking models in ~e series have been tested by the s~tion. Single Action Pull UL ~r compliance to ~e latest requirements of ~e Americans with On dual action models, pushing the Disabilities Act (ADA). FUSH bar causes it to rotate inward, ~~. all~ing the PULL handle to be grasped ~~ Features in a one-handed mo~on. ~e dual a~o~ i"!:i , UL Listed. models are also supplied with break CSFM approved, rods. Dual a~ons m~dels are reset in .~,, ;~ · M~ (BSA) approved, the same way a single a~ion models. · ADA compliant. · Weatherproof model approved for The weatherpmofvemion of the pull .f~ · outdoor use. stations is provided with a gasket and die ~ · Single or dual action, cast metal backbox tapp~ on one end , Te~inals or wire leads, for '/=Anch conduit, f~r sudace mounting. · Key reset models use same keys as Silent Knight enclosures. Dual Action Pull Station · Su~ce mount back boxes available. · High-gloss red enamel finish on die cast metal. ~ SILENT Corrosion-resistant gold-¢ated Die Cast Metal ".- Manual Pull Stations Specifications Switch Rating: 1 amp at 125VAC, or 30VDC. Pull Station Dimensions: 4=/, in. H x 8'/, in. W x 1'/~ in. D. Surface MOunt Backbox Dimensions: 4'/, in. H x 3'/, in. W x 2'/, in. D (cast and sheet metal). Color: Red with raised white letters, white PULL bar with raised red letters. Accessories: All models are supplied with one scared acrylic breakrod and one hex wrench or key. I I I II I II I I I I II I I I I II I ORDERING INFORMATION MODEL PART NO. DESCRIPTION PS~SATK 160050 Pull Station, Single'Action, Terminal COnnection, Key Reset .RS:S.A..WH 160051 Pull S,t.atio, n,, Sin. g!e A, ctt,.o,n., Wire Leads, Hex, Reset PS-DATK 160052 Pull Station, Duel Action, Terminal Connection, Key ReSet PS-SA,TH 160053 Pull Station, Single Action, Terminal Connection, HEX Reset '..: ..F.S-OATH 160054 ,, Pull Station, Dual Actio, n,,. Terminal C. onn,ection, HEX Reset PS-SATK-WP 5310 Pull Station, Single A~lon, Terminal Connection, Key Reset, Weatherproof BOx ,, PS-W ,P,B 160055. . Weatherproof Box .... PS-aB 160056' Back Box PS-GR-12 160057' " Box of 1:2 Scored Acrylici'~reek Rods ..... I III III I I I II I I WIRING DIAGRAM - TERMINALS. WIRING DIAGRAM - WIRE LEAD8 ., Screw Wire To F~re _~ , ~ To Next To Fire = ~ ,--.... ~ To Next Control t or ELR Control '~' ' ' -- or ELR Panel[ Panel BSIf ENT KNIGHT 755(1 Meridian Circle. Maple Cr~rce, MN 55369-4927 1-800-446-8444 or tn M~.nnasota (612) t!93-6435 MADE IN AMERICA FAO<: 1-800-311 - 1715 The DS280 Series are low profile, Photoelectric System type smoke detectors. The patented chamber design provides superior immunity to false alarms caused by dust. Chamber Check® self diagnostics allow the sensitivity to be verified by simply looking at the detector LED. Several different models are' available, offering a wide variety of features and outputs. OPTIONAL ACCESSORIES FEATURING ..... · Direct Wire Design with Removable Terminal Strip · Diagnostic/Sensitivity Test Features l' I · Chamber Check® Self Diagnostics · Field Replaceable Smoke Chamber · Easy Disassembly for Cleaning · Sensitivity Voltage Output · 52 or 24 VDC Operation · 135°F/57°C Heat Sensor Option · UL Listed, ULC Listed 'Detection Systems, Inc. ¢_, Thc h~terJ~arional Leaders of Access, Fire, Intrttsion at~d Sensor Products. SPECIFICATIONS II I /--. ~ POWER REQUIREMENTs 2-wire: '[~.5 ~o 3,3VOC 4-wire: 10 to 30VOC RELAY CONTACTS Form "A": Alarm and Trouble Relay Contacts. 0.SA, 200V {Normally Open). Form "C": Auxiliary Contact, ;A, 220VOC, 250VAC (Normally Operv'Closed/Normaily Closed). RADIO FREQUENCY No alarm or setup on cr~tir~aJ frequencies in bhe range of 26 to 950 Megaherl:z at 50v/re. INTERFERENCE (RFI) IMMUNITY STORAGE ~ OPERAT]N~ +32°F [o +120°F (0°C to 4,0°C) 0 to 95% relative h~idity {non-con0ensing). TEMPERATURE TEST FEATURES LED automalJcally flashes to indicate a calibration ~cuble and latches on alarm. Sensitivity can be vedfied using visual checl<, magnet test or dig~l volt me, tar. CHAMBER CHECK® The ChamDer Check~ automatic sensitivity feature provi0es an indica~on if We detector is outside the fac'ton/calibrated specifications. This feature reduces service costs because the installer can easily determine which detectors require attention. This feature also reduces false alarms by alerting ~ the end-user Nat ~he 0elector is dirty long l~efore the possibility of producing a false alarm. A visual indication is provided in all OS smoke detectors. The OS284THR and OS284THSR ir~lude a trouble relay, allowing this indication to send a report to tl3e central station. P'ATENTED cHAMBER The detection chamber includes computer designed chamber walls and lenses to optimize internal DESIGN light scattering and dust hiding capaDilities. This provides for industr,/leading dust immunity without sacrificing cletecdcn. The detection chamber can be easily' removed should it require cleaning, and is field replaceable. Replacement cham0em are availa~31e in pacl(s of ten (10). SOUNDER 85db sot~ler ~vates on detector alarm or reverse polarity. Available on detectors with '~' in mo(lei number (see [eatures chem. TROUBLE RELAY ' ' Indicates' Chamber Checl~:~ trouble condition or loss oi power (DS284THR and OS2.~4THSR onl,~). ENCLOSURE DESIGN High impact, fire retarciaJ3t kBS plastic enc~o~bre ar~ separate twist-lock mou;3ting plate. T~e DS282 aJ~d DS284 detectom measure 2 in. (5 .c. rn) High by 5 in. (I,2.7 cml iq, O. ia, rn.eter. MOUNTING Segarate mou~ting'pl'ate mounts directly to A-inch octagonal electrical box, single gang box wiremold surface box ~5738. A remove, bio terminal stdp allows for quick installation. HEAT SENSOR 135°F (57~C). -- TEMPERATURE OPTIONAL AccEssoRIES RC3-i0' 'ReplaCem"nt ~;harnDer. E~I ~'00 'End-of-Line Supervision Module. TC2000 Test Corot, PT1 Removal/Test Tool (suitat~ie for testing only, not for installation/removal). · Ship~ed in pac~rages of .... tO. TP280 Trim Plate for retrofit a~.d remo(lelin, g puq3oses. 6 in. (16.2 cml ~lem~ter. .. LISTINGS · U.L. Listing S3019, CSFM #7272o1062:I08. U.S. PATENTS , ~5,400.014,, ~$,543.777, ;~5,552,7S5. ORDERING INFORMATION I I I Oetermined DS282TH 2-wire · ~o,~ · ~v. ~ 0etermined "~'* ~ . , ~/panel DS282THS 2-wire · · ,0,A · ~ZV. ~.~a= Determined zoo~ ,.~ by panel DS282THC 2-wire · · =o~ · ~v. Determined by panel DS284TH 4-wire · "~" ..... ,.,.,,=, DS284THSR 4-wire - · · ~,~, DS284THCS 4-wire · · - "~ · '~v' o~-~^ ,~, DS284THc 4-wire . · "o~e ,~. DS284THE 4-wire · · '~"'" ~'~'""" 082841S 4-wire Isdiated · ,o~e ,~v. ,oo~ ~,=. Detection Systems, Inc. 130 Pednton Parkway, Fairport, New York 14450-9199 (716) 223-4060 · Customer Service (888) 289-0096 · Technical Service (800) 374-7454 · Fax: (716) 223-9180 P/N: 29668H OFFICE OF THE STATE FIRE MARSHAL " FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM Listing Expires June 30, 2000 LISTING SERVICE LISTING No. 7272o1062:108 Page 1 of 1 CATEGORY: Photoelectric Smoke Detectors : LISTEE: Detection Systems, Inc., 130 Perinton Parkway, Fairport, NY 14450 Contact: Frank Mioduszewski (716) 223-4060 DESIGN: Photoelectric type smoke detectors. Models are listed below: DS250, DS250TH DS282, DS282TH, DS282THS*, DS282S* DS284, DS284TH, DS284THC*, DS284THR*, DS284THS*, DS284THCS*, DS284THSR*, DS2841S*, DS284THE% DS284ES*, DS284THES* Model DS250TH, DS282TH and DS284THxx employ an integral 1350 fixed' temperature heat detector. This heat sensor is intended for use only as a supplemental device to assist the smoke detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 33.0 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric Smoke detectors for use with separately listed compatible fire alarm control unit. Models DS250 and DS250TH are intended for use with separately listed bases model MB2W, MB2WL, MB4W, MB4WA or MB4WE. *Rev. 01-O5-98  This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. ~[q'ective issue date to expiration date BEN HO, Deputy State Fire Marshal III Program Manager