HomeMy WebLinkAboutFIRE SUPPRESSION PERMIT 11 22 04 THE OAKS COMMUNITY CHURCH 10200 CAMPUS PARK DRIVE BAKERSFIELD, CALIFORNIA 933 ZONE 10 ~'~?' ~ ,,~ ] ZONE 9 CKT 2 ZONE 1 CKT 3 l, [I ,1 Il ULTI- OS~ R M {{ ~ ...... · ................ ~_ {~ _ _ {{ II CKT 1 ZONE3 ZONE4 ~J .... ;i, _¢~_ MAIN FLOOR DIM. PLAN { FLOOR AREA:,~,i6~ SQ.FT. CKT 6 CKT 5 ZONE 6 ZONE 13 TO ~, ~, FACP G~ROUND FLOOR DIMENSION PLAN LEGEND QUANITY DESCRIPTION MODEL SFM NUMBER 1 IFACP[ FIRE ALARM CONTROL PANEL MS-9600 7165-0075:191 1 ~ FIRE SYSTEM ANNUNCIATOR LCD-80F 7165-0075:190 40 (~ SMOKE DETECTOR SD350T(A) 7272-0075'194 40 ~ FIRE ALARM HORN STROBE AS-24MCW 7125-0785:131 10 [-~ MANUAL PULL STATIONS BG-12 LX 7150-0075:184 i 6 CONTROL MODULE CMF-300 7300-0075:185 3 MINI-MONITOR MODULE MMF-301 7150-0075:184 1 ~) WEATHER PROOF EXT. BELL SUPPLIED BY OTHERS 1 ~ TAMPER SWITCH SUPPLIED BY OTHERS 1 <~ WATER FLOW SWITCH SUPPLIED BY OTHERS 1 Q~ SPRINKLER RISER SUPPLIED BY OTHERS 2 (~ HEAT DETECTORS H355HT 7270-0075' 195 2 ~B~ SMOKE BEAMS 6424 7260-1209:141 (~ FIRE WIRE 18GA 2 CONDUCTOR  FIRE WIRE 18GA 4 CONDUCTOR  DATA WIRE IRPSI REMOTE POWER SUPPLY FCPS-24FS6 7315-0075'206 1 I I FIRE ALARM SYSTEM - SEQUENCE OF OPERATION  SPRINKLER SPRINKLER SPRINKLER 120VAC MANUAL AREA AIR DUCT WATER VALVE POST POWER PULL SMOKE SMOKE FLOW TAMPER INDICATOR FAILER ' ~.~V'~ STATION DETECTOR DETECTOR SWITCH SWITCH SWITCH ON WIRING FAULT SOUND CONTROL PANEL TROUBLE YES YES N/A YES YES YES YES BUZZER CENTRAL STATION FOR YES YES N/A YES N/A N/A N/A ALARM MONITORING CENTRAL STATION FOR YES YES N/A YES YES YES YES TROUBLE MONITORING CENTRAL STATION FOR SUPERVISORY N/A N/A N/A N/A YES YES N/A MONITORING SOUND SPRINKLER BELL N/A N/A N/A YES N/A N/A N/A ANNUNCIATE AT FIRE YES YES N/A YES N/A N/A N/A CONTROL PANEL-ALARM ANNUNCIATE AT FIRE YES YES N/A YES YES YES YES CONTROL PANEL-TROUBLE ANNUNCIATE AT FIRE CONTROL PANEL- N/A N/A N/A N/A YES YES N/A SUPERVISORY ACTIVATE AUDIBLE / ALARM SIGNAL YES YES N/A YES N/A N/A N/A THROUGHOUT BUILDING SHUT DOWN ALL AIR HANDLING (HVAC) N/A YES N/A YES N/A N/A N/A THROUGHOUT BUILDING ELEVATOR RECALL N/A N/A N/A N/A N/A N/A N/A FSD SHUTDOWN N/A YES N/A YES N/A N/A N/A POWER CONSUMPTION SUPERVISORY SUPERVISORY ALARM CURRENT ALARM CURRENT SUB- DEVICE QUANTITY CURRENT SUB, CURRENT EACH EACH TOTAL TOTAL FIRE PANEL I 0.100 0.400 0.100 0.400 SMOKE BEAMS 2 0.010 0.029 0.020 0.058 SMOKE/HEATS 42 0.003 0.065 0.126 2.730 ANNUNCIATOR 1 0.080 0.120 0.080 0.120 TOTALS 0.326 3.308 TOTAL ALARM CURRENT OF 3.308 X .083 (5 MINUTES)= 0.2745640 AH TOTAL SUPERVISORY CURRENT OF 0.326 X 24 HOURS -- 7.82 AH 8.0985640 AH 1.1 SAFETY FACTOR TOTAL AMP HOURS REG UIRED = 8.9084204 AH < 18 AH BATTERY USED VOLTAGE DROP CALCULATION VOLTAGE DROP = CURRENT x WIRE LENGTH x 24 CIRCUIT MILS. VOLTAGE DROP = 0.27 x 800 x 24 4110 VOLTAGE DROP % = VOLTAGE DROP APPLIED VOLTAGE x 100 VOLTAGE DROP % = 1.26 VOLTS 24.00 VOLTS x 100 = 5.25547 CURRENT MC WIRE LENGTH 18 AWG 800 WIRE LENGTH 16 AWG WIRE LENGTH 14 AWG WIRE LENGTH 12 AWG POWER CONSUMPTION SUPERVISORY ALARM CURRENT SUPERVISORY ALARM CURRENT SUB- DEVICE QUANTITY CURRENT SUB, CURRENT EACH EACH TOTAL TOTAL REMOTE POWER I 0.002 0.500 0.002 0.500 HORN/STROBES 40 0.000 0.080 0.000 ' 3.200 SMOKF_J HEATS 0.003 0.065 0.000 0.000 ANNUNCIATOR 0.080 0.120 0.000 0.000 TOTALS 0.002 3.700 TOTAL ALARM CURRENT OF 3.700 X .083 (5 MINUTES)= 0.3071000 AH TOTAL SUPERVISORY CURRENT OF 0.002 X 24 HOURS = 0.05 AH 0.3551000 AH 1.1 SAFETY FACTOR TOTAL AMP HOURS REQUIRED = 0.3906100 AH < 18 AH BATTERY USED VOLTAGE DROP CALCULATION VOLTAGE DROP = CURRENT x WIRE LENGTH x 24 CIRCUIT MILS. VOLTAGE DROP = 0.31 x 750 x 24 4110 VOLTAGE DROP % = VOLTAGE DROP APPLIED VOLTAGE x 100 VOLTAGE DROP % = 1.36 VOLTS 24.00 VOLTS x 100 = 5.65693 CURRENT - MC WIRE LENGTH - 18 AWG 750 WIRE LENGTH - 16 AWG WIRE LENGTH - 14 AWG WIRE LENGTH - 12 AWG HAZARDOUS MATERIALS STATEMENT ~ ' ~ ~ ~ ~ ~ ' ~' k ~ ' f~' ~ ~ L' gl No ~ Will the applicant or future occupant handle hazardoUS materia[or a mixturei:omainfng a hazardous material equal to or greater than thc amounts specified on the r~yes glNo Will the p?ol~osed building or modified facility be within 1000 fi:et o f the o~ter boundary o fa school? i-]yes g}No Wi~theintendedu~¢~fthebui~dingbytheapplicant~rfutur~bui~ding~¢upantrequireapermitf~rc~n~m~c;i~n~rm~di~a~n from the Kern County Air Pollution Control District (KCAP ,CD) or from the City of Bak. Fire I~lat? See ch¢¢klia! for guidelines. Yes CI No I have mad the Hazardous Material Guide and KCAPCD Permitting Checklist. I understand my requirements under the Call f Health and Safety Code Sec. 6.95 and Calif Govt. Sec. 65850 and the requirements of the City of Bakersfield Fire Dept. regarding hazardous materials. Owner or Authorized Agent Phone No '~* Date DECLARATIONS: The declarations below are mandated by the State of California under Section 19825 of the Health and Safety Code. LICENSED CONTRACTOR'S DECLARATION i hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of thc Division 3 of thc Busin~.'ss and Professions Code and my license is in thll three and effect. Lic. Class Lic. No. Exp. Date Contractor's Signalure Date OWNER-BUILDER DECLARATION I hereby afl~rm that under penalty of perjury that I am exempt from the Contractor's License Law tbr the tbllowing reason (Sec. 7031.5 Business and Professions Code: Any city or coufity which requires a permit to construct, alter, improve, demolish, or repair any structure prior to its issuance also requires the applicant lbr such permit to file a signed statement that hc or she is licensed pursuant to the provisions of thc Contractor's License Law (Chapter 9 commencing with Section 7000 of Df vision 3 or thc Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any'applicant Ibr a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)): ~ I,as owneroftheproperty, or my employees with wages as their sole compensation, willdo thework and the structure is not intcndedoroft;.:red ibr sale(Sec. 7044 Business and Professions Code: The Contractor*s License Law does not apply to an owner or'property who builds or improves thcrenn, and who docs such work himself or he,,elf through his or her own employees, provided that such improvements are not intended or offered tbr sale. If, however, thc building or improve- merit is sold within one year of completion, the owner-builder will have the burden of proving that he or she did not build or irnpn~vc lbr thc purpose ol'salc). ~ I. as owner of the property, am exclusively contracting with licensed cont{actors to construct the project (Sec. 7044 Business and Professions Code: Thc Contntctor's License Law does not apply to an owner of property who builds or improves thereon and who contracts tbr such project with a contractor(s) licensed pursuant lo the Contractor License Law). ~ I am exempt under Sec. B.& P.C. for this reason Owner Signature Dale WORKER'S COMPENSATION DECLARATION I hereby affirm that under penalty of perjury one of the tbllowing..di:clarations: I have and will maintain a certilicate o£conscnt to self-insure tbr workers' compensation, as provided tb~' by Section 3700 of thc Labor Code, lbr thc perfonnance of the work for which this permit is issued. ,, I have and will maintain workers' compensation insurance, as required by Section 3700 of tl~e Labor Code, lbr the perfi~rmance of thc work fi.~r which this permit is issued. My workers' compensation insurance carrier and policy number are: Cartier Policy No. I certifiy that in the performance of the work for which this permit is issued, I shall not employ any person in'any manner so as to become subject to the workers' compensation laws of California. and agree that if I should become subject to the workers' compensation provisions of Section 3700 of thc Labor Code. I shall lbrlhwith comply with those provisions. Applicant: Date WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUl,, AND SHAI.L SUB, IECTAN EMPLOYER TO CRIMINAl, PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLl,ARS ~$100,000} IN ADDITION TO THE COST OE COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST. AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency lbr thc perlbrmance of thc work for which this permit is issued (Sen:. 3097 Civ. C.). Lender's Name Lender's Address ,. -., ,. I certili, that tha,e read this application and state that the iatbrmatio, co,ta#red herein is borrect. I agree to comph' ~s, ith all cin' ordi,a,ce~ a,d state laws ,:lati,g to buiMi,g co,stntctio, (ttt~l here~v attthori'.g represe, tatives q/'the ciO' to e, ter tAe above-me, tio,ed propero'.lbr inspection purposes. Signature of Applicant or Agent Date APPROVED BUILDING DIRECTOR By CONSTRUCTION PERMIT.' ''' ~Bakersfield Fire Dept.~  ~ ~ ~evention Se~ces ' ' ' :.-!li~gi='-';Fi~[ ":~ .' '" ' 1715'Chester Ave.'. ~i~=: ~ ...... -:~' Bakersfield, CA 93301 Application Number ..... 04-10000168 , Date 11/22/04 Pin number ......... 420904 Property Address ...... 10200 CAMPUS PARKDR ATN (11 Digits): 394-010-71-00-1 Application description ... . FIRE DEPT Subdivision Name ...... Property Use ........ Application valuation .... 0 owner Contractor ........................ OAKS COMM CH OF CHRSTN & MSNRY S & P MECHANICAL INC 10200 CAMPUS PARK 5812 KLEINPELL AVE BAKERSFIELD CA 93311 BAKERSFIELD BAKERSFIELD CA 93309 325-7-175 Permit ...... FIRE SUPPRESSION PERMIT Additional desc . . Phone Access Code . 259432 Permit Fee .... 912.36 Plan Check Fee . . 364.94 Issue Date . . .... 11/22/04 ~ Valuation .... 0 Expiration Date . . 5/22/05 © Fee summary Charged Paid Credited Due ............... 2 ......................................... Permit Fee Total 912.36 912.36 .00 · .00 Plan Check Total 364.94 364.94 .00 .00 Grand Total 1277.30 1277.30 .00 .00 CALL FOR INSPECTION DECLARATIONS (661) 326-3979 Permit is issued in accordance withali applicable Federal, Sate and Local Odnances. The permitee has property signed and dated the reverse side Please state the Permit Number, the Job Address, and the of this form ' Type of Ispection. Requests for inspections should be made at least 24 (twenty-four) hours in advance. This permit expires after 180 days of inactivity. I ve reviewed the above application, and find it to be correct/complete. Inspectorsoffice hoursare: C~ ' ,'~'~.~.JO "~ 7 am to 5 pm Monday thru Friday _ / ~ ~ Perm-'~-~'~e Date " CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE .... 'EISTING No. 7165-0075:191 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: .Brian Reynolds (203) 484-1200 FAX (203) 484-7309 DESIGN: Model MS-9600 fire alarm control unit. Suitable for non-coded; local, auxiliary, proprietary (protected premises and central station (protected premises) when used with appropriate option modules and additional separate listed equipment; automatic manual, waterflow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description and . operational considerations. System components: MS-9600 Control Unit SLC2 Loop Expander UDACT-F DACT *DACT-UD Digital Alarm Communicator/Transmitter S.ub-assembly 4XTMF Transmission Module BRKT-9600 Module Bracket DP-9600 Dress Panel ACM-8RF Relay Control Module ;TALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. )3 This listing is based upon technical data submitted by the applicant. CSFM Fire Engi the test results and/or other data but does not make an independent verification of any claims, endorsement or recommendation of the item listed. This listing should not be used to verify correct operati~ lements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNI:' 21, 2004 Listing Expires June 30, 2005 Authorized By'.. DIAIVE K, At~E. ND, Senior Deputy ' Program Manager CALIFORNIA DEPARTMENT OF FORESTRy & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE .ISTING No. 7315-0075:206 Page 1 of 1 CATEGORY: Power Units LISTEE: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Brian Reynolds (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FCPS-24FS6 and FCPS-24FS8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circ0its, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. 10-16-2002 JEW  This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 21, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE _ISTING No. 7120-0075:190 Page 1 of 1 CATEGORY: Annunciators LISTEE: Fire-Lite Alarms, One Fire-Lite Place, Northford CT 06472-1653 Contact: Brian Reynolds (203) 484-1200 FAX (203) 484-7309 DESIGN: Model LCD-80F remote fire annunciator. Unit is a compact 80-character, backlit LCD fire annunciator. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciator for use separately listed compatible fire alarm control units. (LF: 7120-0028:209 04-02-01 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results  and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUN~' 21, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A£END, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FOREsTRy & FIRE PROTECTION' OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE _ISTING No. 7272-0075:194 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Fire-Lite Alarms Inc., One Fire-Lite Place, Northford, CT 06472 Contact: Brian Reynolds (203) 484-1200 FAX (203) 484-7309 DESIGN: Models SD350, SD350T, SD355', SD355T* and AD355' photoelectric type smoke detectors. Model SD350T and SD355T* has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units. *All units are suitable for installation inside air duct with a maximum air velocity of 4000 fpm. ~OTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 11-03-2002 BH  This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 21, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7260-1209:141 Page 1 of 1 CATEGORY: Beam Smoke Detection System LISTEE: System Sensor, 3825 Ohio Avenue, St. Charles IL 60174 Contact: *Trish Linhart (630) 377-6674 Fax (630) 377-7245 DESIGN: Model 6424 beam smoke detection system. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a beam smoke detection system for use with separately listed compatible control units. Authority having jurisdiction should be consulted prior to installation. NOTE: Formerly 7257-1209:141 *Rev. 06-16-2003  This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data bu[ does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 Author/zed By: DIANE K. At~END, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF ~FORESTRy & FIRE PROTECTI°N OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDINGMATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:184 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Fire-Lite Alarm Inc., One Fire-Lite Place, Northford CT 06472-1653 Contact: Brian Reynolds (203) 484-1200 FAX (203) 484-7309 DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-12LW, BG-12WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG-12LSP, BG-12SP, BG-12LR, BG-12LRA, BG-12LAO, BG-12LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-12SL, *UT-PS1 and *UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. XLF: 7150-0028:199 *Rev. 08-31-2002 JEW  This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 21, 2004 L/sting Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRy & FIRE pROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:185 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Brian Reynolds (203) 484-1200 FAX (203) 484-7309 DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and *MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. :)VAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. *Rev. 1-24-2003 JEW  This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 21, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A£END, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing~Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -2411 OW audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/*strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP-2575W is also suitable for outdoor use when mounted to Model WPBB back box. *Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDC/VFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, '95:95cd, 100:100cd, 110:110cd *MCW: Selectable 15cd, 30cd, 75cd, 110cd *MCC: Selectable 15cd, 30cd, 75cd, 95cd ~'MCWH: Selectable 135cd, 185cd *MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. *Rev. 03-09-04 Listing No. 7125-0785:131 Page 2 of 2 lARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 or DSMX-12/24 sync control, module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24,-12WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 03-09-04  This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: · MARCH 9, 2004 Listing Expires June 30, 2004 Authorized By: DIANE K. At~END, Senior DePuty Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUfLDING MATERIALS LISTING PROGRAM LISTING SERVICE ~ No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ, 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-#CfW RSSP-#CW RSS-#¢C RSSP-##C RSS-#CCR RSSP-#CCR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 24100 24100 24100 24100 24110 24110 1215 1215 121575 121575 .-- Aisc, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, *RSS-24MCWH, *RSS-24MCWHR, *RSSP-24MCWH, *RSS-24MCCH, *RSS- 24MCCHR, and *RSSP-24MCCH. Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 =16-33VDC/FWR Candela 15=5cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=110cd (Wall) RSS-24MCW, RSSP-24MCW--Selectable 15cd, 30cd, 75cd or 110cd RSS~24MCC, RSS-24MCCR and RSSP-24MCC - Selectable 15cd, 30cd, 75cd and 95cd *RSS-24MCWH, *RSS-24MCWHR, *RSSP-24MCWH - Selectable 135cd, 185cd *RSS-24MCCH, *RSS-24MCCHR, *RSSP-24MCCH- Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. *Rev. 02-03-04 ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: FEBRUARY 3, 2004 Listing Expires June 30, 2004 Authorized By: DIANE K. At~END, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0075:195 Page 1 of I CATEGORY: Heat Detector LISTEE: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Bdan Reynolds (203) 484-1200 FAX (203) 484-7309 DESIGN: Models H350, *H355, and *H355HT fixed temperature heat detectors. Models H350R and *H355R rate-of-rise with fixed temperature heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: *H350, *H355, and *H355HT 135° F fixed temperature *H350R and *H355R 15° F rate-of-rise *H355HT 190° F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Rev. 12-22-2002 JEW  This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 21, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager GENERAL ~ NOTE: The DACT-UD has only The Fire. Lite MS-9600 is a compact, cost-effective, intelli- ~ UL Listing at this time; all other gent addressable fire alarm control panel with a capacity of listings are for the MS-9600 318 addressable Fire. Lite devices on one Signaling Line Cir- panel only. cult (SLC) or a total of 636 addressable points with an op- LISTED California State Fire tional second loop (SLC-2). An optional 14.4K Baud modem (DACT-UD) is available for remote site upload/download and/ $624 ~ Marshal or remote monitoring. 7165-0075:191 Each Signaling Line Circuit (SLC) loop supports up to 159 addressable detectors including photoelectric, photoelectric with heat, ionization, photoelectric duct, fixed heat, fixed heat with rate-of-rise, and fixed high-heat detectors. It also sup- ports up to 159 addressable modules including monitor (two- CS68 wire detector, normally open devices), dual-monitor func- tions (two monitor circuits from one module, two addresses used), control (for Notification Appliance Circuits), and relay (two Form-C) modules. The panel uses surface-mount tech- nology and is designed for ease of installation, programming, and maintenance. It features the latest in advanced fire pro- APPROVED tection technology, including maintenance alert and auto- matic detector test functions. SPECIAL FEATURES: M EA · Optional 14.4K Baud modem. 72-01-E · Selectable strobe synchronization per NAC. · Remote site upload/download. · Four Class B or two Class A NAC circuits. FEATURES SLC Loop: · Fully programmable from local keypad, local PS-2 key- · SLC can be configured for NFPA Style 4, 6, or 7 opera- board or PC via PK-Plus Windows® utility. tion. · Remote site upload/download capability (with DACT-UD). · SLC supports up to 318 addressable devices per loop (159 · Two-level user-programmable passwords. detectors and 159 monitor, control, or relay modules), in- · Custom English labels (per point) may be manually eh- cluding the new addressable dual-monitor module, heat tared or selected from an internal library file. detectors, and duct detector. · Two programmable Form-C relay outputs. · SLC loop maximum length10,000 ft. (3,048 m) @12 AWG · 99 software zones. (3.25 mm2). Requires twisted, shielded wire (3,000 ft./914.4 m untwisted, unshielded wire). User Interface: Notification Appliance Circuits (NACs): · Optional 14.4K Baud modem (DACT-UD). · Four onboard NACs with additional NAC capability using · Remote Acknowledge, Silence, Reset and Ddll via addres- sable monitor modules, ACS Series annunciators or LCD- output control modules (CMF-300 or CMF-300-6). 80F remote annunciator. · Silence Inhibit and Auto Silence timer options. · EIA-232 printer/PC interface (variable baud rate) on main · Continuous, March Time, Temporal or California code for circuit board. main circuit board NACs with two-stage capability. · Integral 80-character LCD display with backlighting. · Selectable strobe synchronization per NAC. · Real-time clock/calendar with automatic daylight savings · 7.0 amps total NAC power, adjustments. Advanced Fire Technology: · History file with 1,000-event capacity. · Sensitivity testing with printable results, onsite or offsite. · EIA-485 supporting up to 32 ACS Series annunciators. · Automatic drift compensation. ° EIA-485 supporting up to 32 LCD-80F annunciators. Programming and Software: · Maintenance alert warns when smoke detector dust ac- . Autoprogram (learn mode) reduces installation time. cumulation is excessive, cont'dpg. 3 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all IS0 9001 specific applications or anticipate all requirements. All specifications are sub- ject to change without not ce For more information contact Fire-Lite Alarms One Fire-Lite Place, Northford, Connecticut 064721 Phone: (800) 627-3473' B~IltlB~NG&~~"~.~ Toll-Free FAX: (877)699-4105. ' QOA,IT, SYS~rL, EIA-485 INTERFACE 24 VDC (DIM-485) built into Optional [~.1 T(~I_ 1 the motherboard DACT-UD - ~-'~'?~?- (four wires) ~ for Central Station ~'" '"' · reporting and remote upload/download [Ic c lj seepho,od ,, ,ow LCD-80F ; ~ ~--~n~ Up to 6,000 ft. (1825.8 m) ~ I SMOKE between each LCD-80F Optional . DETECTORS in the EIA-485 loop, and ~ -- REVERSE SD350, SD350T, CP350, between each LCD-80F POLARITY~ SD355, SD355T, CP355 and the FACP CITY BOX OUTPUT i 24 VDC ~ r , DETECTORS EIA-485 8 FORM-C, 5-AMP RELAYS i H355, H355R in ACS mode (optional, orderACM-8RF) (two wires) ; NACs (Notification DUCT DETECTORS Appliance Circuits) D350P, D350RP ANNUNCIATORS ~- BELLS, SIGNALS, STROBES AFM-LED, LDM, ACS/ACM EIA-232 n n INTERFACE ~ (PIM-24) built inlo the motherboard  ~ MONITOR MMF-300, MDF-300, MMF-302, CMF-300, CRF-300, 1300 PRINTER NOT£: System can use either the printer OR the LCD-8OF.. They cannot be used simultaneously. MINI MONITOR MMF-301 WIRING REQUIREMENTS ~ ADDRESSABLE MULTI-MODULES ' MMF-300-10, The SLC requires use of a specific wire type to MMF-302-6, ensure proper circuit operation. It is recommended CMF-300-6, that all SLC wiring be twisted-pair shielded to mini- CRF-300-6 mize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.75 mm~) DACT;-UD and no larger than 12 AWG (3.25 mm=). The wire size depends on the length of the SLC circuit. Use the table below to determine the specific wiring requirements for the SLC. Wire Distance PULL STATION Requirements in Feet (m) Typical Wire Size BGd2LX 52395dl .wmf Twisted-pair, shielded 10,000 feet 12 AWG (3.25 mm=): Belden 9583, Genesis 4410, (3,048 m) Signal 98230, WPW D999. 8,000 feet 14 AWG (2.00 mmV): Belden 9581, Genesis 4408, Twisted-pair, shielded (2,438 m) Signal 98430, WPW D995. 4,875 feet 16 AWG (1.30 mm=): Belden 9575, Genesis 4406 Twisted-pair, shielded (1,486 m) and 4606, Signal 98630, WPW D991. 3,225 feet 18 AWG (0.75 mm=): Belden 9574, Genesis 4402 Twisted-pair, shielded (983 m) and 4602, Signal 98300, WPW D975. 3,000 feet Unwisted, un~hielded (915 m) 12 - 18 AWG (3.25 - 0.75 mmV). Page 2 of 4 -- DF-52395 · 12/09/03 · Automatic device type-code verification, AUTOMATIC TEST OPERATION · One person audible or silent walk test with walk-test log The MS-9600 performs an automatic test of each detector and printout, every two hours. Failure to meet the test limits causes an · Point trouble identification. AUTO TEST FAIL trouble type. System Reset clears this · Local piezo sounder, trouble. · Waterflow (nonsilenceable) s~lection per monitor point. NFPA STANDARDS · System alarm verification selection per detector point. The MS-9600 complies with the following NFPA 72 Fire AJarm · PAS (Positive Alarm Sequence) and presignal delay per Systems requirements: point (NFPA 72 compliant). · LOCAL (Automatic, Manual, Waterflow and Sprinkler Su- · Optional 4XTMF module (conventional reverse polarity/ pervisory). city box transmitter). · AUXILIARY (Automatic, Manual and Waterflow) (requires CONTROLS AND INDICATORS 4XTMF). LED INDICATORS · REMOTE STATION (Automatic, Manual and Waterfiow) 1. AC POWER (green) (requires 4XT'MF ). 2. FIRE ALARM (red) · PROPRIETARY (Automatic, Manual and Watedlow). 3. SUPERVISORY (yellow) · CENTRAL STATION (Automatic, Manual and Waterfiow, 4. ALARM SILENCED (yellow) and Sprinkler Supervised). 5. SYSTEM TROUBLE (yellow) 6. MAINTENANCE/PRESIGNAL (yellow) SPECIFICATIONS 7. DISABLED (yellow) AC Power - TBI: 120 VAC, 60 Hz, 3.0 amps. Wire size: 8. BATTERY FAULT (yellow) minimum 14 AWG (2.00 mm2) with 600 V insulation. 9. GROUND FAULT (yellow) Battery (lead acid only) - TB2: Maximum charging circuit: MEMBRANE SWITCH CONTROLS Normal fiat charge 27.6 VDC @ 1.0 amp. Maximum battery 1. ACKNOWLEDGE/STEP charger capacity: 25 AH. MS-9600 cabinet holds maximum 2. ALARM SILENCE of two 18 AH batteries. For 25 - 120 AH batteries, use the 3. DRILL CHG-120F or CNG-75 Battery Charger and BB-55F Battery 4. SYSTEM RESET (lamp test) Box. 5 - 16. 12-key pad with full alphabet NOTE: JumperJP3, on the FACP main circuit board, must 17 - 20. 4 cursor keys be cut to disable the FACP battery charger when using the 21. ENTER CHG-120F. FIELD-PROG~ING Frd~TURr:S Communication Loop - (standard) TB8:24 VDC nomi- nal, 27.6 VDC maximum. Maximum length: 10,000 ft. (3048 OFFLINE PROGRAMMING: Create the entire program in m) total twisted, shielded pair length. Maximum loop cur- your office using a Windowsc~i)-based software package (or- rent: 400 mA (short circuit) or 100 mA (normal). Maximum der programming kit PK-CD, containing PK-Plus, separately), loop resistance: 40 ohms. Supervised and power-limited. Upload/download system programming locally to the MS- Notification Appliance Circuits - TB4: Power-limited cir- 9600 in less than one minute, cuitry. Maximum voltage drop in wiring: 2.0 VDC. Nominal A UTOPROGRAMMING: Command the MS-9600 to program operating voltage: 24 VDC. Current limit: fuseless, electronic, itself (takes less than 30 seconds). In the Auto-Program( power-limited circuitry. Maximum signaling current per cir- mode, the MS-9600 scans for all possible devices at all ad-- cult: 7.0 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (PI dresses, stores the device types, and addresses found, and N 71252 UL listed) for NACs. Refer to Fire. Lite Device Corn- then loads default values for all options (General Alarm). It patibility Document for listed compatible devices. also checks for two or more devices set to the same ad- Programmable and Trouble Output Relays - TBS: Con- dress, tact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 ONLINE EDIT: While still providing fire protection, the MS- VAC (resistive). Form-C relays. 9600 may be programmed from the front panel. Simple menu Four-Wire Resettable Smoke Detector Power (24 VDC trees displayed on the LCD allow the trained user to perform nominal) - TB3, Terminals 1(+) & 2(-): Maximum ripple all functions without referring back to the programming voltage: 10 mVRMs. Up to 3.0 amps for powering four-wire manual, smoke detectors. Power-limited circuit. Refer to Fire. Lite ENGLISH LABEL LIBRARY: Quickly select labels from a Device CompatibilityDocumentforlisted compatible devices. standard library of more than 50 adjectives/nouns, such as Nonresettable Power #1 (24 VDC Nominal) -TB3, Termi- "FLR 3 HALLWAY," or enter custom labels letter-by-letter, hals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVF~k4s. Up to Use recall function to repeat previously used label. 0.5 amps total DC current available from each output. Power- PROGRAM CHECK: Automatically catch common errors, limited circuit. TB3, Terminals 5 (+) & 6 (-): non-resettable such as control modules not linked to any zone or input point, power #2. EIA-485 (ACS) - TB6: ACS annunciator connector, Termi- MAINTENANCE ALERT nal 1 (+) and Terminal 2 (-). The MS-9600 continuously monitors each smoke detector EIA-485 (TERM) - TBT: Terminal mode annunciator con- and is capable of reporting maintenance conditions. This hector, Terminal I (Out +), 2 (In +), 3 (Out -), 4 (In -). reduces the dsk of false alarms due to dust accumulation. EIA-232 - TBS: PC/printer connector, Terminal 1 (Trans- Refer to the control panel installation manual for more infor- mit), 2 (Receive), 3 (DTR), 4 (Ground). mation. CABINET SPECIFICATIONS Door: 18.67" (47.43 cra) high x 15.78" (40.08 cra) wide x 1.08" (2.74 cm) deep. Backbox: 18.50" (47.0 cm) high x 15.50" (39.37 cra) wide x 4.37" (11.1 cm) deep. Trim Ring (FC-TR): 21.62" (54.92 cm) high x 18.62" (47.3 cra) wide. DF-52395 · 12/09/03 -- Page 3 of 4 PRODUCT LINE INFO~TION Circuit option requires external 24 VDC to power notification i MS-9600: 318-point addressable Fire Alarm Control Panel, appliances. one SLC loop. Includes 80-character LCD display, single CRF-300: Addressable relay module containing two isolated printed circuit board, and cabinet, sets of Form-C contacts, which operate as a DPDT switch. ' DACT-UD: Optional 14.4KBaud modemforremotesiteupload/ Mounts directly to a 4.0" (10.16 cm) box, surface mount using download and/or remote monitoring, the SMB500. ACM-SRF: Optional plug-in relay module provides 8 Form-C BG-12LX: Addressable manual pull station with interface 5.0 amp relays, module mounted inside. PK-CD: Contains PK-Plus programming software for 1300: This module isoiatas the SLC loop from short circuit Windows~-based PC computer (cable not included), conditions (required for Style 7 operation). SLC-2:Optionalexpandermodule, enablessecondSLCIoop. SMB500: Used to mount all modules exceptthe MMF-301 BRKT-9600: Bracket, mounts UDACT-F and ACM-SRF within and M301. MS-9600 cabinet. MMF-300-10: Ten-input monitor module. Mount one or two DP-9600: Dress panel for MS-9600. modules in a BB-2F cabinet (optional). Mount up to six modules FC-TR: Trim Ring for semi-flush mounting, on a CHS-6 chassis in a BB-6F. BB-$SF: Battery box, required to house two 25 AH batteries MMF-302-6: Six-zone interface module. Mount one or two and one CHG-120F battery charger. For batteries greater modulesinaBB-2Fcabinet(optional).Mountuptosixmodules than 25 AH, consult factory for housing/mounting on a CHS-6 chassis in a BB-6F. arrangements. CMF-300-6: Six-circuit supervised control module. Mount one BB-26: Battery backbox, holds up to two 25 AH batteries, or two modules in a BB-2F cabinet (optional). Mount up to six CHG-t20F: Remote battery charging system for lead-acid modules on a CHS-6 chassis in a BB-6F. batteries with a rating of 25 to 120 AH. CHG-120F or CHG- CRF-300-6: Six Form-C relay control module. Mount one or 75 required for charging greater then 25 AH batteries, two modules in a BB-2F cabinet (optional). Mount up to six CHG-75: Battery charger for lead-acid batteries with a rating modules on a CHS-6 chassis in a BB-6F. of 25 to 75 AH. CHG-120F or CHG-75 required for charging NOTES: f) Compatible with legacy Fire, Lite 300 Series de- greater than 25 AH batteries, vices. Please consult factory for further information on all the PS Series: Batteries, see data sheet DF-5Og70. 300 series devices: CP300, SD300, SD3OOT, M300, M301, BAT Series: Batteries, see data sheet DF-52397. M302, C304, and BG-IOI. X. 2) "A" suffix should be included PRTIPK-CABLE: Cable printer/personal computer interface only when ordering UL C listed units (e.g., SD350A, MMF-3OOA). cable. 3) For more information on Compatible Addrsssable Devices Windows~ is a registered trademark of Microsoft Corporation. for use with the MS-9600, see the following data sheets (docu- ment numbers): AD355 (DF-52386), BG-f2LX (DF-52013), CMF- COMPATIBLE ADDRESSABLE DEVICES 300.6 (DF-52365), CRF-300-6 (DF-52374), CMF/CRF Series (DF-52130), CP350 (DF-52158), CP355 (DF-52383), H355 Se. All feature a polling LED and rotary switches for addressing, r/es (DF-52385), MMF.300 Serles/MDF.300 (DF-5212f), MMF. CP350/CP355: Addressable Iow-profile ionization smoke 300-f0 (DF-52347), MMF-302-6 (DF-52356), SD350/SD350T detector. (DF-52149), SD355/SD355T (DF-52384). SD350/SD355: Addressable Iow-profile photoelectric smoke COMPATIBLE Jt~INUNCIATORS detector. EIA-485 interface: Built into the motherboard. SD350T/SD355T: Addressable Iow-profile photoelectric AFM-LED Zone Series: LED-type fire annunciators capable smoke detector with thermal sensor. of providing up to 99 software zones of annunciation. Avail- H350/H355: Fast-response, Iow-profile heat detector, able in increments of 16 or 32 with expandable (AFM-X Se- H350R/H355R: Fast-response, Iow-profile heat detectorwith ries) and non-expandable (AFM Series) configurations to rate.of-rise option, meet a variety of applications. AD355: Low-profile, intelligent, "Adapt" multi-sensor detector ACS/ACM Annunciator Series: Allows annunciation of loop (B350LP base included), modules and detectors. D3SOP: Photoelectric duct smoke detector. LDM Graphic Series: Lamp Driver Module series for use D350RP: Photoelectric duct smoke detectorwith relayoption, with custom graphic annunciators. MMF-300:AddressableMonitorModuleforonezoneofnormally- LCD-80F (Liquid Crystal Display) point annunciator: 80- open dry-contactinitiatlngdevices. Mountsinstandard4.0"(10.16 character, backlit LCD-type fire annunciators capable of dis- crn) box. Includes plastic cover plate and end-of-line resistor, playing English-language text. Up to 32 LCD-80F annuncia- Module may be configured for either a Style B (Class B) or Style tors may be connected to the EIA-485 terminal mode serial D (Class A) IDC. interface on the MS-9600 motherboard. MDF-300: Dual Monitor Module. Same as MMF-300 except NOTE: For more information on Compatible Annunciators it provides two Style B (Class B) only IDCs. for use with the MS-9600, see the following data sheets (docu- merit numbers) AFM/AFM-X Series (DF-51465), ACM-SRF MMF-301: Miniature version of MMF-300. Excludes LED and (DF-5 ~ 555), ACS/ACM Series (DF-52378), LDM Series (DF- Style D option. Connects with wire pigtails. May mount in 51384), LCD-80F (DF-52185). device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 AGENCY LISTINGS AND APPROVALS conventional two-wire detectors. Requires resettable 24 VDC See the first page of this data sheet for listing agencies and power. Consult factory for compatible smoke detectors, file numbers. These listings and approvals apply to the ha- CMF-300: Addressable Control ModuleforoneStyle Y/Z (Class sic MS-9600 control panel. In some cases, certain modules B/A)zoneofsupervisedpolarizedNo~calJonAppliances. Mounts may not be listed by certain approval agencies, or listing directlytoa 4.0"(10.16cm)electricalbox. NotificationAppliance may be in process. Consult factory for latest listing status. Page 4 of 4 -- DF-52395 · 12/09/03 24 Volt, 6 Amp Remote Power Supply I Section: Power Supplies/Accessories GENERAL (~ California The FCPS-24FS6 is a compact, cost-effective, 6-amp re- State Fire mote power supplywith battery charger. The FCPS-24FS6 Marshal may be connected to any 12- or 24-volt Fire Alarm Control 7315-0075:206 LISTED Panel (FACP) or may be stand alone. Pdmary applica- tions include Notification Appliance (bell) Circuit (NAC) S2424 expansion (to support ADA requirements and NAC syn- chronization) or auxiliary power to support 24-volt system accessories. The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Cir- cuits configured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS-24FS6 also contains a battery charger capable of charging up to 18 Amp Hour batteries. FEATURES · UL Listed NAC Synchronization using System Sensor, Wheelock or Gentex appliances. · Cascadable up to 10 power supplies with strobe timing maintained. · Operates asa syncfollowerora syncgenerator(default). * See note on reverse side. · Contains two, fully-isolated input/control circuits (tdg- · Selectable earth fault detection. gered from FACP Notification Appliance Circuit [NAC · AC trouble report selectable for immediate or 8 hour expander mode] or jumpered permanently on [stand- delay. alone mode]). · Works with virtually any UL 864 fire alarm control which o Optional mounting kit, P/N 90286, to internally house utilizes an industry-standard reverse-polarity notifica- addressable SLC control module (CRF-300 or CMF- tion circuit (including unfiltered and unregulated bell 300) for alarm activation, power). · Four Class B (Style Y) or four Class A (Style Z) (with · Requires input trigger voltage of 9.0 - 32 VDC. ZNAC-4 Module) Notification Appliance Circuits. · Self-contained in compact, Iockable cabinet (15" [381 · 6 Amp full Icad output (3 amps max./ckt.) in NAC ex- mm]Hx 14.5" [368 mm]Wx 2.75"[70 mm] D). pander mode (UL 864). · Includes integral battery charger capable of charging up · 4 Amp continuous output in stand-alone mode (UL to 18 AH batteries. Cabinet capable of housing 7.0 AH 1481). batteries. · In stand-alone mode, output power circuits may be · Battery charger may be disabled via dip switch for appli- configured as resettable (reset line from FACP required) cations requiring larger batteries. or non-resettable or a mix of two and two. · Fixed, clamp-type terminal blocks accommodate up to · Fully regulated and filtered power output (optimal for 12 AWG (3.25 mm2) wire. powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered STANDARDS and CODES power). The FCPS-24FS6 complies with the following standards: ° Power-limiting technology meets UL power-limiting re- · NFPA 72-1996 National Fire Alarm Code. quirements. · UL 864 Standard for Control Units for Fire Alarm Systems · Form-C normally-closed trouble relay. (NAC expander mode). · Fully supervised power supply, battery and Notification · UL 1481 Power Supplies for Fire Alarm Systems Appliance Circuits. (stand-alone mode). ~This document is not intended to be used for installation purposes. We try to keep our product information~ accurate. We cannot cover all specific applications or anticipate all requirements. AllI i up-to-data and I specifications are subject to change without notice. For more information, contact Fire°Lite Alarms, One~ I Fire-Lite Place, Northford, Connecticut 06472. / I Phone: (800) 627-3473 Toll Free FAX: (877) 699-4105 / DF-52301 -- Page 1 of 2 SPECIFICATIONS Output Circuits Pdmary (AC) Power · +24 VDC filtered, regulated. · FCPS-24FS6:120 VAC 60 Hz, 3.2 A max. · 3.0 amps maximum for any one circuit. · Wire size: minimum #14 AWG (2.0 mm=) with 600V · 4.0 amps maximum total continuous current for all insulation, outputs (Stand-alone mode). Control Input Circuit · 6.0 amps maximum total short-term current for all out- - Trigger Input Voltage: 9.0 to 32 VDC. puts (NAC Expander mode). Secondary Power (Battery) Charging Circuit · Tdgger Current: 2.0 mA (16 - 32 V). · Supports lead acid batteries only. (per input) 1.0 mA (9 - 16 V). · Float Charge Voltage: 27.6VDC. Trouble Contact Rating · Maximum Charge Currant: 1.5 amps · 5 amps at 24 VDC. · Maximum Battery Capacity: 18 AH. Auxiliary Power Output · Specific Application Power - 500 mA maximum. ORDERING INFORMATION FCPS-24FS6 Remote charger power supply (120 ZNAC-4 Class A (Style Z) NAC option module VAC). Includes main pdnted circuit A77-716B 12/24 VDC end-of-line relay for monitoring board, transformers, red enclosure, and 4-wira smoke detector power. installation instructions. PS-1270 Battery, 12 volt, 7.0AH (two required). PIN 90286 FCPS-24F Module Mounting Kit APPLICATIONS Example I Example 3 Expand notification appliance power an additional 6.0 Use addressable control modules to activate the FCPS- amps. Use up to 4 Class B (Style Y) outputs or 4 Class A 24FS6 versus the FACP Notification Appliance Circuits. This (Style Z) outputs (using the ZNAC-4). typically allows for mounting the FCPS-24FS6 at greater In this example, the FACP notification appliance circuits distances* away from the FACP while expanding system will activate the FCPS-24FS6 when reverse polarity acti- architecture in various applications. vation occurs. Trouble conditions on the FCPS-24FS6 In this example, an addressable control module is used to are sensed by the FACP through Notification Appliance activate the FCPS-24FS6 and an addressable monitor Circuit. module is used to sense FCPS-24FS6 trouble conditions. Local auxiliary power output from the FCPS-24FS6 pro- Example 2 vides power to the addrassable control module. Use the FCPS-24FS6 to expand auxiliary regulated 24 volt system power up to 4 amps. Both non-rasettable and *Fire,Lite's MS-9200, MS-9200UD, (198-point) or MS-9600 (636- resettable power options are available, point) Addressable FACP's have the capability of locating control and monitor modules up to 10,000 feet away. Resettable outputs are created by connecting the resettable output from the FACP to one or both of the FCPS-24FS6 inputs. * Note: In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by a Fira Alarm Control Panel such as the Fira-Lite MS-9600. When installed at the end of a MS-9600 NAC wira run, this power supply can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wira run. This maintains the overall system flash timing of the additional strobes attached to this power supply. When this power supply is configured (via dip switch settings) as a "sync follower'', this supply's NAC outputs track the strobe synchronization pulses prasent at this supply's sync input terminal, The pulses ara originated from an upstraam F^CP or other power supply. When this power supply is configured (via dip switch settings) as a "sync generator'', this supply's sync input terminal ara not used. Rather, this power supply is the originator of the strobe synchronization pulses on this power supply's NAC outputs. In "sync generator" mode the sync type (System Sensor, Wheelock, or Gentex) is selectable via dip switch settings. Page 2 of 2 -- DF-52301 July 1, 2003 DF-52185 - B-150 LCD-80F Fire. LITe®ALarms 80-Character Liquid Crystal Display Remote Fire Annunciator www. firelite.com Section: Annunciators GENERAL ~ ~ ~California The LCD-80F is a compact,.cost-effective, 80-character, State Fire backlit LCD remote Fire Annunciator for use with the Marshal Fire. Lite MS-9200UD and MS-9600 Fire Alarm Control Pan- 7120-0075:190 els (FACPs). The LCD-80F displays complete system point status information and includes control switches for remote LISTED CS635 control of critical system functions. S2424 Up to 32 LCD-80Fs may be connected Onto the EIA-485 terminal port (mB7) of each FACP. The LCD-80F requires APPROVED no programming, which saves time during system commis- sioning. FEATURES r -- .. · 80-character Liquid Crystal Display. · Mimics all display information from the host · Control switches for System Acknowledge, ~ ~ Signal Silence, Drill and Reset with enable ~ key. LEDs for "-:;~:-' System status Power, Alarm, Trouble, Supervisory and Alarm Silenced. ~.:..~::~ ,i-~i- · No programming necessary-- LCD-80F con- ~ ~-~ nects to the terminal port (TB7) on the FACP. ~.~ ;s..,~ · Displays device type identifiers, individual point alarm, trouble or supervisory, zone and custom alpha labels. · Time-and-date display field. · Aesthetically pleasing design. LCD-80F · May be powered by 24 VDC from the host FACP or by remote power supplies (requires 24 VDC). The LCD-80F provides the FACP with up to 32 remote se- - Up to 32 LCD-80F annunciators per FACP. rialiy connected annunciators. All field-wiring terminations on the LCD-80F use removable, compression-type termi- - Plug-in terminal blocks for ease of installation and ser- nal blocks for ease of wiring and circuit testing. vice. Communication between the FACP and the annunciators · Can be remotely located up to 6,000 feet (1828.8 m) from is accomplished over an EIA-485 serial interface, which the FACP. greatly reduces wire and installation cost over traditional · Local piezo sounder with alarm and trouble resound, systems. Six wires total are required: four for the EIA-485 · Semi-flush mounts to 2.188" (5.556 cra) minimum deep, communications (two in and two return); and two for the 24 three-gang electrical box (Fire-Lite PIN 10103) or three- VDC regulated power. Dip switches control local functions gangable electrical switchbox, such as: piezo disable, control switches/key-switch disable, · Surface-mounts to Fire-Lite SBB-3 surface backbox, transmitJreceive mode. OPERATION INSTALLATION The LCD-80F annunciator provides the FACP with point The LCD-80F can be semi-flush mounted to a 2.188" (5,556 annunciation with full display text on an 80-character LCD cm) minimum deep, three-gang electrical box (Fire-Lite P/N display. The LCD-80F also provides an array of LEDs to 10103) or three-ga, ngable electrical switchboxes. Alter- indicate system status, and includes control switches for nately, an SBB-3 surface backbox is available for surface- remote control of critical system functions, mount applications. This document is not intended to be used for installation purposes. We try to ~ keep our product information up-to-date and accurate. We cannot coverall I ISO 9001 specific applications or anticipate all requirements. All specifications are sub- ject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. I~l~J~l I~"~ S~'~'I:M~ UadeintheU.S.A. DF-52185 · 07/02103 -- Page I of 4 PRODUCT LINE INFORMATION 10103 Three-gang electrical box, minimum 2.188" LCD-80F 80-character, backlit, LCD Fire Annunciator with (5.556 cm) deep, for semi-flush mount applica- control switches for remote control of system tigris. functions, and key-switch lock. SBB-3 Three-gang surface backbox for surface-mount applications. LCD-80F TERMINAL MODE WIRING EXAMPLE Up to 6,000 lt. (1828.8 m) between ' EACH DEVICE in the EIA-485 Ioop~ Terminal Mode / LCD-80F ~ LCD-80F~'"'"-~ 24 VDC (2-wires) ~ ( ~ - -- -- -- J ~ - ~.L - LCD-80F · / beck from last device ~~ ~ /to end of EIA-485 loop -~ ~ ~ ~ ~ 4 Terminal Mode EIA-485 return Addressable (2-wires) Fire Alarm Control Panel Notes: 1) EIA-485: Maximum of 6,000 feet (1828.8 m) cable length 3) Between each LCD-80F annunciator are four wires: a from FACP to LCD-80F annunciators, 6,000 feet cable twisted-shielded pair for data communications and a pair length between each LCD-80F and 6,000 feet from the last for 24 VDC power. The return circuit only requires two wires LCD-80F back to the FACP. Circuit is power-limited. (twisted) for data communication supervision, wired from 2) Up to 32 LCD-80F annunciators may be used on the EIA- the last LCD-80F annunciator on the loop. 485 circuit. When multiple LCD-80Fs are used, the FACP will require additional power supplies (refer to panel docu- mentation). MOUNTING TO BACKBOX(ES) Mounting The LCD-80F annunciators can be semi-flush mounted in Holes (4) a three-gang electrical box with a minimum depth of 2.188" .~ (5.556 cm) (Fire-Lite PIN 10103). © LCD-80F flange The LCD-80F annunciators can be mounted in three- FIRE ALARM ANNUNCIATOR NOTE: Alternately, LCD-80F annunciators can be mounted :: :- FIRE-LITE ALARMS. INC. to the SBB-3 surface backbox for surface-mount applica- ~.~ SYSTEMS ALL NORMAL tions. . ] I :06A 032001 ~ Electrical Installer's Note: This annunciator'may not fit ~-~ ':~ - ............... "' ..... easily ,nto a standard 3-gang electdcal box if locking clamps ~ ~ ~ ~ ~ are used to secure wiring entering the rear or side knock- outs..Only use the TOP or BOTTOM knockouts to bring F~ F~ wiring into a standard 3-gang electrical box. 5.813" (14.764 cm) wide x 4.0" (t0.16 cra) ' .. high x minimum 2. f88" (5.556 cm) deep, .. three-gang electrical box (Fire.Lite P/N - 10103, shown at right). Page 2 of 2 -- DF-52185 · 07/02/03 re-uTe® carms SD355(A)/SD35. 5T(A) Addressoble Photoelectric Detectors www. firelite, com Section: Addressable Devices I GENERAL ~ ~ ~ California State Fire The SD355 and SD355T addressable, Iow-profile plug-in Marshal photoelectric detectors use a state-of-the-art photoelectric 7272-0075:194 sensing chamber with communications to provide open area protection and are used exclusively with Fire. Lite's MS- LISTED 9200, MS-9200UD, and MS-9600 Addressable Fire Alarm M EA Control Panels (FACPs). The SD355T adds thermal sen- sots that will alarm at a fixed temperature of 135°F (57°C). 243-02-E Since these detectors are addressable, they will help emer- APPROVED gency personnel quickly locate a fire dudng its early stages, potentially saving precious rescue time while also reduc- lng property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED an- ~~~l~,,~l.~- (p/Nnunciat°rRA400z).Capability is available as an optional accessory [ ?'~ ~- - - FEATURES , SLC loop: · Two-wire loop connection. ~ . · Unit uses base for widng. Addressing: SD355 with~- -~ · Addressable by device. B350LP base/.~.~-~--~L~, · Direct Decade 01 - 99 (MS-9200, MS-9200UD) and 01 - 159 (MS-9600) entry of address. Architecture: ' t. · Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. ,~u,,,,,,6~:T,,,,, -~.~ ~-./~--.. ~/ · Sleek, Iow-profile design. B350LP base '-'-.~_. · Integral communications and built-in type identification. · Built-in tamper-resistant feature. · Removable cover and insect-resistant screen for simple field cleaning. Operation: Other system features: · Withstands air velocities up to 1,500 feet-per-minute (7.6 · Fully coated circuit boards and supedor RF/transient pro- tection. m/sec.) without triggering a false alarm. · 94-V0 plastic flammability rating. · Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. · Low standby current. · Visible LED "blinks" when the unit is addressed (com- Options: municating with the fire panel) and latches on in alarm. · Remote LED output connection (P/N RA400Z). Mechanicals: APPLICATIONS · Sealed against back pressure. Use photoelectric detectors in life-safety applications to pro- · Direct surface mounting or electrical box mounting, vide a broad range of fire-sensing capability, especially · Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 where smoldering fires are anticipated. Ionization detec- cra) octagonal box, or 4.0" (10.16 cra) square electrical tors are often better than photoelectric detectors at sens- box (using a plaster ring -- included), lng fast, flaming fires. This document is not intended to be used for installation purposes. We try to keep our product ISO§001 information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire. Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. ~'"~ =" ~' d · -- · =, .] Phone; (800) 627-3473, Toll-Free FAX: (877) 699-4105. Blilr4~lll & ~ DF-52384 · 04/11/03 -- Page 1 of 2 CONSTRUCTION SPECIFICATIONS These detectors are constructed of off-white LEXAN®. Voltage range: 15- 32 VDC (peak). SD355(T) plug-in, Iow-profile smoke detectors are designed Standby current: 300 pA @ 24 VDC. to commercial standards and offer an attractive appear- LED current: 6.5 mA @ 24 VDC (latched "ON"). ance. LEXAN® is a registered trademark of GE Plastics, a subsidiary of Air velocity: 1,500 ff./min. (7.6 m/sec.) maximum. General Electric Company. Diameter: 6.1" (15.5 cm) installed in B350LP base. INSTALLATION Height: 2.1" (5.33 cm) installed in B350LP base. Weight: 3.6 oz. (102 g). SD350(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount Operating temperature range: for SD355: 0°C to 49°C base on box which is at least 1.5 inches (3.81 cm) deep. (32°F to 120°F) $D350; for SD3$ST: 0°C to 38°C (32°F to Suitable boxes include: 100°F)· · 4.0" (10.16 cm) square box with plaster ting. Temperature: 0°C - 49°C (32°F - 120°F). · 4.0" (10.16 cm) octagonal box. Relative humidity: 10% - 93%, non-condensing. · 3.5" (8.89 cm) octagonal box. PRODUCT LINE INFORMATION · Single-gang box. NOTE: "A" suffix indicates ULC-Listed model. NOTE: Because of the inherent supervision provided by the SLC SD355 Addressable photoelectric detector (B350LP loop, end-of-line resistors are not required. Wiring "T-taps" or base included). branches are permitted for Style 4 (Class B) wirfng. SD355A Same as SD355 with ULC Listing (B350LPA OPERATION base included). Each SD355(T) uses one of 99 possible addresses on the SD355T Same as SD355 but with thermal element MS-9200 and MS-9200UD Signaling Line Circuit (SLC), or (B350LP base included). up to 318 (159 on each loop) on the MS-9600 SLC. It re- SD355TA Same as SD355T with ULC Listing (B350LPA sponds to regular polls from the system and reports its type base included). and status. RA400Z(A) Remote LED. Mounts to a single-gang box. The SD355(T) addressable photoelectric sensor's unique unipolar chamber responds quickly and uniformly to a broad B350LP(A) Plug-in detector base (included). Dimen- range of smoke conditions and can withstand wind gusts sions: 6.1" (15.5 cra). Mounting:4.0" (10.16 up to 1,500 feet-per-minute (7.6 m/sec.) without sending cm) square box with or without plastic ring, an alarm level signal. Because of its unipolar chamber, the 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) SD355(T) is approximately two times more responsive than octagonal box, or single-gang box. All mount- most photoelectric sensors. This makes it a more stable lng boxes have a minimum depth of 1.5" (3.81 detector, cra). B224RB(A) Plug-in System Sensor relay detector base. DETECTOR SENSITIVITY TEST Diameter: 6.2" (15.75 cra). Mounting: 4.0" Each detector can have their sensitivity tested (required (10.16 cm)square box with or without plastic per NFPA 72, Chapter 7 on Inspection, Testing and Main- dng, 4.0" (10.16 cm) octagonal box, or 3.5" tenance) when installed/connected to an MS-9200, MS- (8.89 cm) octagonal box. All mounting boxes 9200UD, or MS-9600 addressable fire alarm control panel, have a minimum depth of 1.5" (3.81 cm). The results of the sensitivity test can be printed off the MS- B501BH(A) Plug-in System Sensor sounder detector 9200, MS-9200UD, or MS-9600 for record keeping, base. Diameter: 6.0" (15.24 cm). Mounting: 4.0" (10.16 cra) square box with or without plastic ring. Mounting box has a minimum depth of 1.5" (3.81 cm). Page 2 of 2 -- DF-52384 · 04/11/03 ! June 13, 1997 F-700 I 6424 Fire. LITe® ALarms Projected Beam Smoke Detector Section: Conventional Initiating Devices ~ ~ ~CalJfornia ~NI~RJ~_L State Fire Marshal The System Sensor Model 6424 Beam Detector is ideal to meet the unique fire protection challenge of atriums and 7260-1209:141 other open areas with high ceilings. LISTED 053o8 The System Sensor Model 6424 Beam Detector is de- S911' signed for four-wire, 24 VDC applications. M EA This stylish, two-component infrared detector consists of a 427-91-E 0V6A1 .AY separate transmitter and receiver. Together they can protect a linear distance from 30' to 330'. Multiple units spaced between 30 and 60 feet apart can be used to cover larger areas. If 95% or more of the beam is blocked, a trouble condition is signaled. This blockage must be removed before the unit can reset itself and return to normal. FEATURES · Unique LED alignment technique makes setup fast and easy. · Four LEDs on the front of the receiver provide positive visual indication of maximum signal strength. · No special meters or alignment tools are necessary. 6424 · Receiver and transmitter can be powered separately or together. System Sensor's unique LED alignment technique as- - Detects a broad range of fires, sums the fast and easy setup. No special meters or · Ceiling and wall mount brackets included, alignment tools are necessary. Four LEDs on the front of the receiver provide all the help needed to lock transmitter · Calibrated test filters included, and receiver together for maximum signal strength and · Form A (Alarm) and B (Trouble) contacts, protection. · Remote test station option. A built-in automatic gain control compensates for the grad- - Three-year warranty, ual deterioration of signal strength from dust accumula- tion, component aging and temperature fluctuations. The APPLICATIONS receiver and transmitter can be powered separately or The System Sensor Model 6424 Beam Detector is particu- together for maximum flexibility in installation. Sensitivity larly well suited for use in atriums, ballrooms, churches, selectable at 30% or 55% Total Obscuration. Them is warehouses, museums, factories, and other large or high- also a choice of test filters to allow convenient checking of ceiling areas where conventional smoke detectors cannot detector sensitivity under varying conditions. Operating be easily installed, temperature range is -22°F to 131°F (~30°C to 55°C). For further information, see "Guide for Proper Use of Beam CON~rRUCTION & OPEIL~TION Smoke Detectors," document 156-506-00. The two-component System Sensor Model 6424 detector PRODUCT LI#! consists of a separate infrared transmitter and receiver. Model Description The units mount on opposite walls or on the ceiling across from each other and are designed to detect any smoke in 6424 Projected Beam Smoke Detector. a linear distance from 30' to 330'. Since both absorption RTS451 Remote Test Station. and scattering of the beam's infrared light is detected as a reduction in signal, the System Sensor Model 6424 works RA400Z Remote Annunciator. well on both smoldering and fast-flaming fires. A77-716B End-of-Line Relay, 24 VDC. This document is not intended to be used for installation purposes. We try to keep our product information up-to-dateandaccurate. We cannotcoverallspecificapplicationsoranticipeteall ISO gO01 requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627- 3473, Toll Free FAX: (877) 699-4105, FAX Back:(888) 388-3299 ~ WEB: www.firelite.com EN~I~~I~N~ & M.l~r~l~d~ DF-50934 -- Page 1 of 4 SPECIFICATIONS ENGINEERING SPECIFICATIONS Operational The projected beam type smoke detector shall be a 4-wire 24 VDC device to be used with UL listed separately sup- Range: 30' to 330' (length). plied four-wire control panels only. Unit shall be listed to Smoke detector spacing: On smooth ceilings, 60' be- UL 268 and shall consist of a separate transmitter and tween projected beams and not more than one-half that receiver capable of being powered separately or together. spacing between a projected beam and a sidewall. Other The detector shall operate in either a short range (30' - spacing may be used depending on ceiling height, airflow 100') or long range (100' - 330') mode. The temperature characteristics, and response requirements. See NFPA range of the beam shall be -22°F to 131°F. The detector 72 A-5-3.5.5.2. shall feature a bank of tour alignment LEDs on both the receiver and transmitter that are used to ensure proper Sensitivity: 30% ± 5% total obscuration OR 55% + 5% alignment of unit without special tools. Beam detector total obscuration, shall feature automatic gain control which will compensate Fault condition (Trouble): 95% or more obscuration; for gradual signal deterioration from dirt accumulation on automatic gain control limit; improper initial alignment, lenses. Unit shall include both ceiling and wall mounting Test/Reset features: Obscuration filter; local reset switch; brackets. Testing shall be carried out using calibrated test remote test and reset switch capability (compatible with filters or magnet activated remote test station. RTS451 test station). Indicators: ALARM -- Local red LED TROUBLE -- Local amber LED WIRING DIAGRAMS NORMAL -- Local flashing green LED AlignmentLEDs). aid: Integral signal strength indication (4 red POWER (+)© _4~~~ Relaya: Alarm, Trouble. EOL relay is required to super- vise power. /SIGNALI Environmental ~-' T~0US'EI Temperature: -30°C to 55°C (-22°F to 131°F). SIGNAL Humidity: 95% RH non-condensing. Mechanical POWER (-) AUX (')10oRANGE~- Dimensions: With no bracket, 2.5"H x 8.5"W x 7"D. --© With ceiling mount bracket, 5.5"H x 8.5"W x 7"D. With wall mount bracket, 5.5"H x 8.5"W x 10"D. 6424 Remote Outputs Weight: Receiver, 1.5 lb. (663 g). Transmitter, 1.3 lb. (598 g), Mounting: Separate ceiling and wall brackets. ~ 6424 Remote Outputs Wiring: Plug with attached cable. Electrical (Receiver) Voltage: 20 to 32 VDC. Maximum ripple voltage: 30% of nominal (peak to peak). Current (24 VDC): ALARM WHITE-BROWNSTRIPEI G 1 Standby: 10.0 mA maximum. SIGNAL -O ORANGE Alarm: 28.4 mA maximum. AUX (-) ~O _~ 2 Trouble: 27.1 mA maximum. L__~_~ 4 Start-up surge: 19.0 mA maximum. Relay contacts: 0.5 A at 30 VAC/DC. YELLOW RESET ~:~ (~ 3 Reset time: 0.6 seconds maximum. BLUE Start-up time: I minute maximum (after 5 minute reset). TEST -O (~ 5 Power loss: Retain memory for 5 minute minimum. Electrical (Transmifler) 6424 '~ RTS451 REMOTE Voltage: 18.8 to 32.0 VDC. TEST STATION Maximum ripple voltage: 30% of nominal (peak to peak). ~ Remote Test Station Connection Current (24 VDC, stenclby and alarm): 10.0 mA max. Page 2 of 4 -- DF-50934 WIRING DIAGRAMS, continued Class A Return Loop ................................................................................ EOL Power Supervision I WHITE- WHITE- WHITE. WHITE- Relay Module YELLOW RED YELLOW RED (shown energized) STRIPE© ~ © STRIPE STRIPE © ~ © STRIPE :: , l~: : WH, T~BLACK WHITE-BLACK :: :I __ __ ~oGRAY STRIPE © __ ©GRAY Initiating STRIPE 0 y ~ i i Loop WHITE © .7~__ © VIOLET WHITE© __.~ ~:~ VIOLET ~t RED. WHITE WHITE-VIOLET RED-WHITF WHITE. VIOLET Power to + STRIPE © © STRIPE STRIPE© © STRIPE E Detectors BLACK© Receiver ©BROWN BLACK© Receiver ©BROWN UL Listod Panol ?ransmitter & Reoeiver Powered Together Transmitter Transmitter Class A ............................................................................................ Return Loop .................................................................................... EOL Power j Supervision WHITE- WHITE- WHITE- WHITE- Relay Module YELLOW RED YELLOW RED STRIPEo ~ 0 STRIPE STRIPE 0 ~ 0 STRIPE (shown energized) WHITE-BLACK __ ©GRAY STRIPE C~ -- ©GRAY ' ' Initiating STRIPE ©__~ '~ :: ; Loop WHITE © __~__ © VIOLET WHITE© __~7~ O VIOLET ~ ' RED-WHITE' WHITE-VIOLET RED-WHITE WHITE-VIOLET Power to -I- STRIPE © © STRIPE STRIPE© © STRIPE EOL Resistor ] Detectors BLACK© Receiver ©BROWN BLACK© Receiver o BROWN ORANGE ~ ~ GREEN ORANGE ~ ~ GREEN i i Optional Temporary Wiring ' , for Transmitter Alignment Aid BLACK (~ ~ RED BLACK ~ ~ RED UL Listed Panel Remote ~ GREEN~ ©WHITE GREW% Transmitter & Receiver Power Powered Separately Soume 8LUE ~:~ oBROWN BLUEo_ Transmitter Transmitter Power Inputs to Transmitter are Nonpolar DF-50934 -- Page 3 of 4 MOUNTING DIAGRAMS HORIZONTAL ADJUSTMENT HORIZONTAL SCREW ADJUSTMENT (#10-24 x 2-1/4") SCREW METAL WASHER (#10-24 x 1-3/8") METAL WASHER '~ / PLASTIC WASHER ~ CEILING MOUNTING X~//PLASTIc wAsHER ~C~~-/ BRACKET ~---~,,~- ~ II ~'~ It I /~b, I~i/,'~-~-.~ "1 ',J J VERTICAL ~/~'~'~'~/,~-~ 4!I I _.[' t VERTICAL ..-/'/~.~[~ ~J~--"~,[ ~ Iii ~ ~.~ ADJUSTMENT ..~/~,~o.~ ~ ][{ ~ / ADJUSTMENT /'~k ~ ~ ~\ ~--J,!r'F~ SCREWS (2) STATUS 1,7 ~,~ ~_:_.?."~ "~- ~'~-~'/~x~ / \ "/' ~ "~-'-- ~1 '% EGRESS ) ~ "~:~ ~-'" &>~,-. ~ ~ CABLE EGRESS / ~- / ~' -/ HOLE PLUG LEDs / ',% /' ~'-'~"~-- ,J ' HOLE PLUG STATUS ~ ~%- --'/ Used to plug (,~R.,E,C,,E, IVER ~ ?-.. ~.~ Used to plug- LEDs -~=,,,~ unused hole ~m~.~ unused ho e. ( R ECE~'EIVERE ........... B/RAM LENS~'~~ ........... ~ ...... ONLY) , ALIGNMENT ADJUST ~ ~.~ur~r~=m~/~u,~u~ .q POTENTIOMETER POTENTIOMETER HOLE PLUG ~ (RECEIVER ONLY) HOLE PLUG /A~ (RECEIVER ONLY) ~ Ceiling Mounting ~ Wall Mounting REAR VIEWS SHOWING SWITCHES AND CABLES ACCESS DOOR~ ~~ HOLE PLUG // ~ o ' Receiver SELECT SWlTCH~ ~ Shown in / ~ ~/ ~ Can o~ro~ ~ith~r sido. ALIGNMENT / RES~ MODE SWITCH SWITCH Shown In Normal CABLE Mode position. CONNECTOR EXIT PLUG ACCESS DOOR HOLE PLUG Rear View, ~ ALIGNME T ransmiffer MODE SWlTC Shown in Align Mode position. ~ 6 CONDUCTOR CONNECTOR CABLE RANGE S~L~GT 8~ITGH Shown in Con~ ~an~o p~ition. GENERAL ~ ~~ California State Fire The Fire-Lite BG-12LX is a state-of-the-art, dual-action Marshal (i.e., requires two motions to activate the station) pull sta- ~JS 7150-0075:184 tion that includes an addressable interface (mounted in- side) for FireoLite's addressable MS-9200 and MS-9600 fire alarm control panels. Because the BG-12LX is ad- dressable, the control panel can display the exact loca- tion of the activated manual pull station. This leads fire APPROVED service personnel quickly to the location of the alarm. FEATURES · Aesthetically pleasing, highly visible, dual-action design. · Meets ADA 5 lb. maximum pull force. · Easily operated (dual-action). ° Attractive shape and textured finish. ° Mounts, semi-flush, to a standard single-gang (2.125" [5.3975 cm] minimum depth), double-gang, or 4" (10.16 cm) square electrical box. · When the handle latches in down position, the word "ACTIVATED" appears at the top of the handle in bright yellow to clearly indicate the station has been operated. · Key/lock reset; needs only a 1/4-turn to lock/unlock. · Includes Braille text on station handle. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). · Optional trim ring (BG-TR). · Meets UL 38, Standard for Manually Actuated Signaling Boxes. · Maintenance personnel can open station (for inspection and testing) without causing an alarm condition. BG-12LX · Built-in bicolor LED, which is visible through the handle of the station, flashes red in normal operation and latches on steady red when in alarm. Manual stations connect with two wires to one of the con- CONSTRUCTION trol panel SLC loops. Each manual station, on command Shell, door, and handle are molded of durable LEXAN® from the control panel, sends data to the panel represent- (or polycarbonate equivalent) with a textured finish, lng the state of the pull station switch. Two rotary decimal switches allow address settings (01-99). OPERATION PRODUCT LINE INFORMATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the BG-12LX Dual-action addressabie pull station. word "ACTIVATED" (in bright yellow) appears at the top of includes key lock/reset feature. the handle, while a portion of the handle protrudes from SB-10 Surface backbox. the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; closing the door automati- cally resets the switch. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. 4This document is not intended to be used for installation purposes. We try to keePl our product information up-to-date and accurate. We cannot cover all specific, lSQ 900.1 applications or anticipate all requirements. All specifications are subject to change! without notice. For more information, contact Fire-Lite Alarms, One Fire-Life Place, I Northford, Connecticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699-I 105, FAX Back:(8e~l 388-3299. '~" ~ Made in the U S A DF-52013 -- Page 1 of 2 INSTALLATION ARCHITECTURAL! The BG-12LX can be semi-flush mounted into a single- ENGINEERING SPECIFICATIONS gang, double-gang, or standard 4' (10.16 cm) square elec- Manual Fire Alarm Stations shall be non-code, with a key- trical outlet box, or surface mounted to the Model SB-10 operated reset lock in order that they may be tested, and surface backbox. If the BG-12LX is semi-flush mounted, so designed that after actual Emergency Operation, they then the optional trim ring (BG-TR) may be used. The BG- cannot be restored to normal except by use of a key. An TR is usually needed for semi-flush mounting with 4" operated station shall automatically condition itself so as (10.16 cm) or double-gang boxes (not with single-gang to be visually detected as activated. Manual stations shall boxes), be constructed of red-colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions pro- ELECTRICAL SPECIFICATIONS vided on the cover. The word FIRE shall appear on the Normal operating voltage: 24 VDC. front of the stations in white letters, 1.00 inches (25.4 mm) Maximum SLC loop voltage: 28.0 VDC. or larger. Stations shall be suitable for surface mounting on matching backbox SB-10; or semi-flush mounting on a Maximum SLCIoopcurrent: 230pA. standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities ACt (ADA) or per national/local requirements. Manual Stations shall  be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the ~ c:~ ~ c~ ~ control panel SLC loops. The manual station shall, on t 2 3 4 command from the control panel, send data to the panel I~ ~ ~ " representing the state of the manual switch. Manual  stations shall provide address setting by use of rotary '~*~: i 'l ~ ~ decimal switches. ~ ~ -- - TERMINAL CONNECTIONS I SLC (-) 2 SLC (+) Back of station without door. I -~TARY DECIMA I I ~ Cover open to show easy access to MMX module, rotary switch, and UL label. Page 2 of 2 -- DF-52013 April 23, 2001 DF-52121 E-325I I MMF-300 SeHes/MDF-300 I FI re. LiTe® ALarmsAddressable Monitor Modules I www. firelite, com Section: Addressable Devices GENERAL (~ ~ ~ Four different monitor modules are available for Fire. Lite Alarm's MS-9200 and MS-9600 intelligent fire alarm control panels to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input devices, such as con- ventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). 7300-0075:185 MMF-300 (Replaces M300) -- The MMF-300 Moni- tor Module is a standard-sized module (typically mounts to a 4" [101.6 mm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input de- r~ MMF-30t (Replaces M3Ot)--The MMF-301 is a Min- ~ iature Monitor Module (a mere 1.3" (33.02 mm) H x 2.75" (69.85 mm) W x 0.5" (12.70 mm) D) used to supervise a Class B (Style B) circuit. Its compact design allows the MMF- iD .?~_ 301 to be mounted in a single-gang box behind the device it is monitoring. ~ MMF-302 (Replaces M302)- The MMF-302 Inter- :7 T~'?'~'~ face Module is a standard-sized module used to monitor and ~ .-.~ supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. .5 '~'~"~ MDF-300 (New) --The MDF-300 Dual Monitor ModuleL o.~ is a standard-sized module (typically mounts to a 4" [101.6 I ~ ~_oo,~ ~o~--~ mm] square box) that supervises two Class B (Style B) cir- cuits of dry-contact input devices. ~} (~ MMF-300 MONITOR MODULE ~ · Built-in type identification automatically identifies this de- MMF-300, MMF-302 and MDF-300 vice as a monitor module to the control panel. · Powered directly by two-wire SLC loop. No additional terminates the Style B circuit. No resistor Is required for su- power required, pervision of the Style D circuit. Maximum IDC resistance is · High noise (EMF/RFI) immunity. 1,500 ohms. · SEMS screws with clamping plates for ease of wiring. MMF-300 Operation -- Each MMF-300 uses one of · Direct Decade 01 - 99 (MS-9200) and 01-159 (MS-9600) 99 (MS-9200) or 159 (MS-9600) available module addresses entry of address, on an SLC loop. It responds to regular polls from the control · LED flashes green during normal operation and latches panel and reports its type and the status (open/normal/short) on steady md to indicate alarm, of its Initiating Device Circuit (IDC). A flashing LED indicates The MMF-300 Monitor Module is intended for use in intelli- that the module is in communication with the control panel. gent, two-wire systems, whom the individual address of each The LED latches steady on alarm (subject to current limita- module is selected using the built-in rotary switches. It pro- tions on the loop). vides either a two-wire or four-wire Class A or Class B fault- MMF-300 Specifications tolerant Initiating Device Circuit (IDC) for normally-open-con- Nominal operating voltage: 15 to 32 VDC. tact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300 can be used Maximum current draw: 5.1 mA (LED on). to replace M300 modules in existing systems. Average operating current: 400 pA (LED flashing). MMF-300 Applications -- Use to monitor a zone of EOL resistance: 47K ohms. four-wire smoke detectors, manual fire alarm pull stations, Temperature range: 32°F to 120°F (0°C to 49°C). waterflow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally- Humidity range: 10% to 93% noncondensing. open supervisory devices with special supervisory indica- Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x tion at the control panel. Monitored circuit may be wired as 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square an NFPA Style B (Class B) or Style D (Class D) Initiating x 2.125" (53.975 mm) deep box. Device Circuit. A 47K ohm End-of-Line Resistor (provided) This documentisnotinte~dedtobeusedforinstallaflollpurposes. We try to keep our ISO 9001 )roduct information up-to-date and accurate. We cannot cover all specific applica- tions or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, ~[l..'i' '. Connecticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699-4105, FAX ~ack:(888~ 388-3299. Made in the U.S.A. ~ DF-52121 -- Page I of 3 MMF-301 MINI MONITOR MODULE MMF-302 INTERFACE MODULE · Built-in type identification automatically identifies this de- · Supports .compatible two-wire smoke detectors. vice as a monitor module to the MS-9200. · Supervises IDC wiring and connection of extemal power · Powered directly by two-wire SLC Loop. No additional source (resettable). power required. · High noise (EMF/RFI) immunity. · High noise (EMF/RFI) immunity. · SEMS screws with clamping plates for ease of wiring. · Tinned, stripped leads for ease of wiring. · Direct-dial entry of address (01-99). · Direct-dial entry of address (01-99). · LED flashes during normal operation (this is a program- The MMF-3Ol Mini Monitor Module can be installed in a mable option). single-gang junction directly behind the monitored unit. Its · LED latches steady to indicate alarm on command from small size and light weight allow it to be installed without rigid control panel. mounting. The MMF-301 is intended for use in intelligent, The MMF-302 Interface Module is intended for use in intel- two-wire systems where the individual address of each mod- ligent, addressable systems, where the individual address ule is selected using rotary switches. It provides a two-wire of each module is selected using built-in rotary switches. This initiating device circuit for normally-open-contact fire alarm module allows intelligent panels to interface and monitor two- and security devices. The MMF-301 can be used to replace wire conventional smoke detectors. It transmits the status M301 module in existing systems. (normal, open, or alarm) of one full zone of conventional de- tectors back to the control panel. All two-wire detectors be- ~.~...-..~1415 0 ~ ADDRESS ~-"~,2 lng monitored must be UL compatible with the module. 112~///"~23 '/ /.~V~\ \ 3~ MMF-302 Applications -- Use the MMF-302 to mona- 11~4 LOOP ~,/F/JJ,~,} )~, tor a zone of two-wire smoke detectors. The monitored cir- )~,,.~,~ ~-~ 9 ~8~7 6 5 cult may be wired as an NFPA Style B (Class B)or Style D 10 ~ 5 . . (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line TENS ONES Resistor (provided) terminates the end of the Style B or D ~ (class B or A) circuit (maximum aDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D ap- plication. MMF-302 Operation -- Each MMF-302 uses one of 159 (MS-9600 only) available module addresses on an SLC ~ loop. It responds to regular polls from the control panel and · _~ reports its type and the status (open/normal/short) of its Ini- ~ tiating Device Circuit (IDC). A flashing LED indicates that _~ the module is in communication with the control panel. The ~ LED latches steady on alarm (subject to current limitations on the loop). MMF-302 Specifications MMF-301 Applications -- Use to monitor a single de- Nominal operating voltage: 15 to 32 VDC. vice or a zone of four-wire smoke detectors, manual fire Maximum current draw: 5.1 mA (LED on). alarm pull stations, waterflow devices, or other normally-open Average operating current: 270 pA (LED flashing). dry-contact devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- EOL resistance: 3.9K ohms. tion at the control panel. Monitored circuit/device is wired as External supply voltage (between Terminals T3 and T4): an NFPA Style B (Class B) Initiating Device Circuit. A 47K DC voltage: 18 to 28 volts power limited. Ripple voltage: ohm End-of-Line Resistor (provided) terminates the circuit. 0.1 VRMS maximum. Current: 90 mA per module maximum. MMF-30t Operation -- Each MMF-301 uses one of Temperature range: 32°F to 120°F (0°C to 49°C). 159 (MS-9600 only) available module addresses on an SLC Humidity range: 10% to 93% noncondensing. loop, It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Ina- Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1,25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square tiating Device Circuit (IDC). x 2.125" (53.975 mm) deep box. MMF-301 Specifications Nominal operating voltage: 15 to 32 VDC. MDF-300 DUAL MONITOR MODULE Average operating current: 375 IJA maximum. · Built-in type identification automatically identifies this de- EOL resistance: 47K ohms, vice as two monitor modules to the control panel. · Powered directly by the two-wire SLC loop. No additional Temperature range: 32°F to 120°F (0°C to 49°C). power required. Humidity range: 10% to 93% noncondensing. · High noise (EMF/RFI) immunity. Dimensions: 1.3" (33.02 mm) high x 2.75" (69.85 mm) wide · SEMS screws with clamping plates for ease of wiring. x 0.5" (12.70 mm) deep. · Direct-dial entry of address 01 - 159 on the MS-9600. Wire length: 6" (152.4 mm) minimum. · LED flashes green during normal operation and latches on steady red to indicate alarm. The MDF-300 Dual Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides two independant two-wire fault-tolerant Initiating Device Circuits (IDCs) at two separate, consecutive ad- Page 2 of 3 -- DF-52121 dresses. It is capable of monitoring normally open-contact PRODUCT LINE INFORMATION fire alarm and supervisory devices, or either normally open or normally closed secudty devices. The module has a single MMF-300 Monitor Module. panel-controlled red LED indicator. MMF-301 Mini Monitor Module. MDF-300 Applications - Use to monitor a zone of four- MMF-302 Two-Wire Detector Monitor Module. wire smoke detectors, manual fire alarm pull stations, MDF-300 Dual Monitor Module. waterflow devices, or other normally-open dry-contact alarm SMB500 Optional Surface-Mount Backbox. activation devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- MOUNTING DIAGRAMS tion at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) Initiating Device Circuit. The for standard-sized modules 47K ohm End-of-Line Resistors (provided) terminate the Style B circuit. Maximum IDC resistance is 1,500 ohms. MDF-300 Operation - Each MDF-300 uses two of 99 (MS-9200) or 159 (MS-g600) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normaVshort) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MDF-300 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 750 pA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wire resistance: 1,500 Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 electrical box. INSTALLATION MMF-300, MMF-302 and MDF-300 modules mount directly to a standard 4" (101.6 mm) square, 2.125" (53.975 mm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu-. lations. These modules are intended for power-limited wir- ing only. The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. ARCHITECTS'/ENGINEEIIS' SPECIFICATIONS Specifications of these and all Fire-Lite Alarms products are available from Fire. Lite Alarms. DF-52121 -- Page 3 of 3 September 28, 2001 DF-52130 E-350 I CMF and CRF Series FIre-LITe® ALarms Addressable Control and Relay Modules www. firelite.com Section: Addressable Devices GENERAL -- CMF'aOOC°ntr°lM°dule(ReplacesCao4) u~ The CMF-300 Addressable Control Module provides Fire. Lite Alarm's MS-9200 and M$-9600 intelligent control Approved panels a supervised Class B (Style Y) or Class A (Style Z) circuit for Notification Appliances (horns, strobes, etc.). Addressability allows the CMF to be activated, either manu- 73o~-~75:~ss ally or through panel programming, on a select (zone or area of coverage) basis. CRF-300 Relay Module (Replaces C304 configured as a relay) ~ ~-~ MS-9200 and MS-9600 systems with ~t~_o isolated sets of o Form-C dry-contact outputs for activating a variety of auxil- iary devices, such as fans, dampers, door holders, con- trol equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel program- ming, on a select basis. FEATURES · Built-in type identification automatically identifies these devices to the control panel. __ · Internal circuitry and relay powered directly by two-wire SLC loop. The CMF module requires power (for horns, strobes, etc.). · Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. CMF-300 and CRF-300 Module · High noise immunity (EMF/RFI). · The CMF may be used to switch 24-volt NAC power. OPE~I~.TiON · Wide viewing angle of LED. Each CMF or CRF uses one of 99 (MS-9200) or 159 (MS- . SEMS screws with clamping plates for wiring ease. 9600) possible module addresses on a SLC loop. It re- . Direct Decade 01-99 (MS-9200) and 01-159 (MS-9600) sponds to regular polls from the control panel and reports entry of address, its type and status, including the open/normal/short sta- APPLICATIONS tus of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates The CMF is used to switch 24 VDC audible/visual power, its internal relay. The CMF supervises Class B (Style Y) or The CRF may be programmed to operate dry contacts for Class A (Style Z) notification or control circuits. door holders, Air Handling Unit shutdown, etc. Upon code command from the panel, the CMF will discon- CONSTRUCTION nect the supervision and connect the external power sup- . The face plate is made of off-white Noryl®. ply in the proper polarity across the load device. The dis- connection of the supervision provides a positive indica- · Controls include two rotary switches for direct-dial entry tion to the panel that the control relay actually turned ON. of address (01-99 on the M$-9200 and 01-159 on the The external power supply is always relay isolated from MS-9600). the communication loop so that a trouble condition on the · The CMF is configured for a single Class B (Style Y) or external power supply will never interfere with the rest of Class A (Style Z) Notification Appliance Circuit. the system. · The CRF provides two Form-C dry contacts that switch Rotary switches set a unique address for each module. together. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module Noryl® is a registered trademark of GE Plastics, a subsidiary of to the control panel, so as to differentiate between a mod- General Electric Company. ule and a sensor address. -isd°cument is n°t intended t° be used f°r installati°n purp°ses' We try t° keePl r product information up-to-date and accurate. We cannotcoverallspecificllSO go01 plications or anticipate all requirements. All specifications are subject to change! Jwithout notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, ~Northford, Connecticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699-~ pto~, ~^x ~ac~:p~I ~s~-~2~. I ' DF-52130 -- Page 1 of 2 SPECIFICATIONS FOR CMF RELAY CONTACT RATINGS Normal operating voltage: 15 to 32 VDC. for both CMF and CRF models Maximum current draw: 5.1 mA (LED on). Load Description Application Maximum Current Average operating current: 390 pA (LED flashing). Voltage Rating External supply voltage (between Terminals T3 and T4): Resistive Non-Coded 30 VDC 3.0 A maximum 80 volts (RMS or DC). Resislive Coded 30 VDC 2.0 A Drain on external supply: 2 mA maximum (using internal EOL relay)· Resistive Non-Coded 1110 VDC 0.9 A EOL resistance: 47K ohms. Resisl~ve Non-Coded 125 VAC 0.9 A Inductive (L/R = 5 ms) Coded 30 VDC 0.5 A Temperature range: 32°F to 120°F (0°C to 49°C). Inductive (I_/R = 2 ms) Coded 30 VDC 1.0 A Humidity range: 10% to 93% non-condensing. Inductive (PF = 0,35) Non-Coded 125 VAC 0.5 A Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square 6724,at,.~ x 2.125" (53.975 mm) deep box. SPECIFICATIONS FOR CRF Normal operating voltage: 15 to 32 YDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C), Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide · x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. PRODUCT LINE INFORMATION ~ CMF-300 Intelligent Addressable Control Module. CRF-300 Intelligent Addressable Relay Module. SMB500 Optional Surface-Mount Backbox. CB500 Control Module Barrier -- required by UL for separating power-limited and non-power lim- ited wiring in the same junction box as CMF-300. MOUNTING I~ DIAGRAMS Note CB500 Module Barrier, which creates isolated quadrant. I ~ I ~ I [ ~ ~'-~ C'~II x..~t~1' 'ISOLATED ~ QUADRANT ~ 4" (101.6 mm) square x 2,125" (53.975 mm) deep box Page 2 of 2 -- DF-52130 ~) ~ California  State Fire O~i~iBUi_ Marshal Wheelock's new two-wire (patent pending) AS Series Au- 7125-0785:131 dible Strobe Devices and AH Series Audible Devices fea- ture less current draw and reduced inrush. The audible CS 356 provides a selectable choice of either a continuous horn tone or a temporal pattern (Code 3) tone when constant voltage E 5946 from a Fire Alarm Control Panel (FACP) is applied. Each tone M EA 0B6A2.AY has three dBA settings to choose from. All models (audible only or audible/strobe) may be synchronized when used in 151-92-E (SM/DSM) conjunction with the SM or DSM Sync Module. Additionally, the audible may be silenced while maintaining strobe activa- tion on combination AS Series units. AS Series Audible Strobes and AH Series Audibles are de- signed for maximum pedormance, reliability, and cost-effec- tiveness while meeting or exceeding the latest requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (Ameri- can National Standard for Accessible and Usable Buildings and Facilities) and UL Standard 1971 (Standard for Signaling Devices for the Hearing Impaired) and UL 464 (Audible Signal Appliances). AS Series Audible Strobe Devices, when prop- erly specified and installed in accordance with NFPA/ANSI standards, can provide the Equivalent Facilitation allowed under ADA Accessibility Guidelines (ADAAG General Section 2.2) by meeting or exceeding the illumination which re~ults from the ADA specified strobe intensity of 75 candela at 50 feet (15.24 m). This is an illumination of 0.030 lumens per AS Audible Strobe AH Audible square foot. When used with Wheelock SM and/or DSM Sync Modules, synchronization of the continuous horn tone provides the temporal (Code 3) tone (mandated by NFPA-72 [1993] with Temporal (Code 3) tone: anechoic at 90, 95, or 99 dBA; an effective date of July 1996) simultaneously for all audible reverberant at 75, 82, or 85 dBA. devices. This ensures a distinct temporal (Code 3) pattern o Patented Universal Mounting Plate allows mountingt°single- when two or more audibles are within hearing distance. If not gang, double-gang, 4" (10.16 cra), or 100 mm European synchronized, the temporal could overlap and not be distinc- backboxes, or to the SHBB surface backbox. No additional tive. At the same time, the strobes will be synchronized. This trim plates are required. provides the ability to comply with ADA recommendations concerning photosensitive epilepsy and NFPA standards when · AS Series Audible Strobe Devices are available in wall- and ceiling-mount models: installing two or more visual devices within the field of view. Wall-mount models are available in 15, 15/75, 30, 75, and These features, and the ability to silence the audible devices, 110 candela intensities. The 15/75 candela wall-mounted are achieved using only two wires, strobes are listed at 15 candela under UL Standard 1971 and meet 75 candela intensity on axis for ADA guidelines with Iow FF~'URES current draw. · ADA/NFPA/ANSIcompliant. Meets OSHA 29 Part1910.165. Ceiling-mount models are offered in 75 and 100 candela · UL1971 listedforSignalingDevicesfortheHearinglmpaired intensities. and UL Standard 464 for Audible Signal Appliances. · All models can be synchronized by adding the SM or · Lower current draw and reduced inrush. DSM Sync Module to the NAC circuit: · Patented two-wire device. Sync the audible: Maintain the temporal pattern when two · Selectable for continuous horn or temporal (Code 3) tones, or more devices are within an area. Meets NFPA require- . Field-selectable dBA levels for both tone varieties: ment for Temporal Evacuation Notification. Continuous tone: anechoic at 90, 95, or 99 dBA; reverber- Sync the strobe: Maintain true one-flash-per-second when ant at 82, 88, or 91 dBA. using two or more visual devices within the field of view. Meets ADA and NFPA requirements, specify a flash rate of I to 3 flashes per second. Silence the audible while maintaining the strobe flash, · All candela ratings represent minimum effective strobe in- option, tensity based on UL 1971. · All features on two wires. · AS Series Strobe products are listed under UL 1971 for · 12- and 24-volt models available, indoor use with a temperature range of 32°F to 120°F (0°C to · AH Series Audible Devices are available in two models: 49°C) and maximum humidity of 85%. AH-12 or AH.24 Indoor Audible Horn is enclosed in a grille · AH Series horns are listed under UL 464 for audible signal matching that of the AS Series Audible Strobes. appliances. AH-12WPorAH-24WP(weatherproof)canbeinstalledin- · AH-12WP and AH-24WP audible devices are listed under UL doore or outdoors. When used outdoors, they must be used 464 for indoor/outdoor use with a temperature range of-31°F with a WBB-R weatherproof backbox, to 150°F (-35°C to 66°C) and maximum humidity of 95%. GENERAL NOTES /~WARNINGII' PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED · Strebesaredesignedtoflashatlflashpersecondminimum INSTALLATION INSTRUCTIONS CAREFULLY BEFORE US- from 20 to 31 VDC (for 24 VDC models), or 10.5 to 15.6 VDC lNG, SPECIFYING, OR APPLYING THIS PRODUCT. FAILURE (for 12 VDC models). Note that N FPA-72 (1996) specifies a TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, flash rate of I to 2 flashes per second, and ADA guidelines CAUTIONS, AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH ORDERING INFORMATION COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. MODEL NUMBER VOLTAGE I CANDELA OPTIONS* MODEL NUMBER I VOLTAGE I CANDELA OPTIONS* AS-2415W-FR 24VDC I 15 A,B,D,F,G,O,R,XI IAS-2475C'FW I 24VDC I 75 A,B,D,F,G,R,V,X ^s-2430w-F. 24v00 I 30 ^,B,D,F,G,o,.,x I I^H',2." I 12vDo I ^S- 475W-F. .VOC I I I I24wc I ^S-24.OW- . 4VDO I A,B,D,F,G,O,R,X I IAH''2wP'" I 2vDc I K AS-1215W-FR 12VDC 15 A,B,D,F,G,O,R,X I IAH'24WP'R I 24VDC I K AS-121575W-FR 12 VDC 15/75 A, B, D, F, G, O, R, X ~ ~ SYNC MODULES** INPUT VOLTAGE AVERAGE CURRENT MOUNTING OPTIONS* SM-12/24-R 12 VDC /24 VDC 0.014 (12 VDC) / 0.025 (24 VDC) E, N DSM-12/24-R 12 VDC /24 VDC 0.020 (12 VDC) / 0.038 (24 VDC) W NOTES: 1) COLORS: Wall-mount models offered in red; ceiling-mount models offered in white. 2) SUFFIXES USED ABOVE: W -- Wall mounting; C = Ceiling mounting; WP = Weatherproofing; F = Fire lettering; R at end = Red plate; W at end = White plate. EXAMPLES: AS-2415W-FR (Wall mounting - Fire lettering, Red plate); AS-2475C-FW (Ceiling mounting - Fire lettering, White plate). · For descriptions of MOUNTING OPTIONS, refer to Fire. Lite data sheet DF-51744, derived from Wheelock #S7000. · * SM Sync Modules are rated for 3.0 amperes at 12 or 24 VDC; DSM Dual Control Modules are rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to installation instructions for SM (Wheelock #P83123) and DSM (Wheelock #P83177). '~' AVERAGE CURRENT Average Current (Amperes)* at Low/IVledium/High Audible Settings Voltage: 20 VDC. 24 VDC 3t VDC 10.5 VDC 12 VDC 15.6 VDC Settings: LO MEO HI LO MED HI LO MED HI LO MED HI LO MED HI LO MED HI 90 95 99 90 95 99 90 95 99 90 95 99 90 95 99 9095 991 Model: dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA AS-2415W-FR :0.070 0.074 0.088 0.064 0,072 0.0~7 0.058 0,067 0,090 AS-241575W-FR 0,084 0.089 0.105 0.077 0.053 0.102 0,057 0.077 0.100 AS-2430W-FR 0.111 0.116 0.128 0.098 0.105 0.120 0.084 0.092 0.119 AS-2475W-FR i0,178 0.184 0.200 0,149 0,156 0.177 0,117 0.130 0.152 AS-24110W-FR 0.210 0.216 0.230 0.177 0.183 0.202 0.148 0.158 0.183 ,~S-1215W-FR -- -- 0.184 0.205 0.248 0.162 0.191 0.238 0.145 0.179 0.233 AS-121575W-FR -- -- 0.250 0.207 0.317 0,211 0.231 0,285 0.174 0.200 0.258 AS-2475C-FW 0.279 0.287 0.306 0.230 0.238 0.261 0.284 0.294 0.329 AS-24100C-FW 0.317 i 0.324 ~ 0.340 0.265 0.272 0.292 0.334 0.340 0.366 AH-12-R -- -- -- 0.030 0.037 0.093 0.035 0.043 0.100 0.040 0.056 0.128 AH-24-R 0.014 0.020 10.035 0.017 0.024 0.041 0.021 0.030 0.053 AH-12WP-R -- -- -- 0.030 0.037 0.093 0.035 0.043 0.100 0.040 0.056 0,128 AH-24WP-R 0.014 0.020 0.035 0.017!0.024 0.041 0.021 0.030 0.053 · Average current per actual Wheelock Production Testing @ 10..5, 12, 15.6, 20, 24, and 31 VDC. For rated average and peak current across the UL listed voltage range for both filtered and unfiltered V~MS, see installation instructions (Wheelock #P83509 [AS] and #P~5~g [AH]). Page 2 of 4 -- DF-51898 FEATURES QUICK REFERENCE ~U.L CEILING SYNC'S vd STROBE 24 VDC 12 VDC RED WHITE MODEL NUMBER MOUNT MOUNT NON.SYNC SM or DSM CANDELA AS-2415W-FR X X X 15 X X AS-241575W-FR X X X 15/75 X X AS-2430W-FR X X X 30 X X ' AS-2475W-FR X X X 75 X X AS-24110W-FR X X X 110 X X AS-1215W-FR X X X 15 X X AS-121575W-FR X X X 15/75 X X AS-2475C-FW X X X 75 X X AS-24100C-FW X X X 100 X X AH-12-R X X X X X X AH-24-R , X X X X X I X AH-12WP-R X X X X X X AH-24WP-R X X X X X X AS devices synchronized with SM Module WIRING DIAGRA/VIS single Claes "B" (Style Y) circuit WITH audible silence feature. AS device non-synchronized. PRECEDING ® + STROBE DEVICE DEVICE STROBE or FACP or EOLR NAC CIRCUIT ® - STROBE ~/+ OUT SIGNAL ~9.x- OUT l ~i AUDIBLE * EOLR VALUE AS and AH devices synchronized with AUDIBLE EOLR* DETERMINED DSM Module dual Class "A" (Style Z) '~' NAC CIRCUIT BY FACP circuit with NO audible silence feature. AUDIBLE NAC CIRCUIT(S). DSM ® SYNC + AS and AH devices synchronized ' ® SYNC- with multiple DSM Modules, ~/+ OUT 1 INTERCONNECTING WIRING SHOWN, ~INUS 1 MAXIMUM OF TWENTY (20) DSM MODULES. AUDIBLE DSM #1 ~ + AUDIBLE NAC I t STROBE · I I NAC ® SYNC + I ICIRCUIT ®SYNC- ~ - AUDIBLE ~bllNUS 2 I I AUDIBLE I I NAC DSM #2 + OUT 2 ) ISTROBE · SYNC + SYNC - NOTES: I ]CIRCUIT · AS/AH must be set on continuous horn tone, and I IAUDIBLE connected to the SM or DSM Sync Module, to achieve I I NAC DSM #3 · For details on using SM or DSM Sync Modules, refer to Wheelock data sheet #S3000, or Wheelock installation ~ STROBE A instructions #P83123 (for SM) or #P83177 (for DSM). NAC SYNC + ~ CIRCUIT SYNC- DF-51898 -- Page 3 of 4 /~WARNING!V CONTACT WHEELOCK FOR "INSTALLATION INSTRUCTIONS" (Wheelock #P83509 [AS], #P83641 [AH-WP], and #P83519 [AH]) AND "GENERAL INFORMATION" SHEET (Wheelock #P82380) ON THESE PRODUCTS. THESE MATERIALS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMA- TION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: · TOTAL CURRENT REQUIRED BY ALL DEVICES CONNECTED TO SYSTEM PRIMARY AND SECONDARY POWER SOURCES. · FUSE RATINGS ON NAC CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL DEVICES ON THOSE CIRCUITS. ,, COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. · VOLTAGE APPLIED: THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. · INSTALLATION OF 100/110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. · INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. · Note: USE AS/AH ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE AS SERIES ON CODED OR INTERRUPTED NAC CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF, AS THE STROBE MAY NOT FLASH. · CONDUCTOR SPECIFICATIONS: CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS iNJURY OR DEATH TO YOU AND/OR OTHERS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained, and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state, and federal codes, regulations, and laws. Specification, application, installation, operation, maintenance, and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal, and other applicable building and fire standards, guidelines, regulations, laws, and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AH J). ARCHITECTS' & ENGINEERS~ SPECIFICATIONS · The notification appliances shall be Wheelock's patented AS Series Audible Strobe and AH Series Audible Horn devices, and when synchronization is required, companion SM and DSM Sync Modules, or approved equivalents. AS Series devices and SM and DSM Sync Modules shall be listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired for Indoor Fire Protection Service). AH Series Audible Horn shall be listed under Standard 464 (Fire Protective Signaling). AS, AH, SM, and DSM devices shall be certified to meet FCC Part 15, Class B. · The devices shall be designed for two-wire operation and shall provide either a continuous or temporal (Code 3) tone when constant voltage from a Notification Appliance Circuit (NACs) of the Fire Alarm Control Panel (FACP) is applied; or synchronized temporal (Code 3) horn and synchronized strobe when used in conjunction with the SM or DSM Sync Modules. · The AS Series shall be designed so that the audible signal may be silenced while maintaining strobe activation (when used with the SM or DSM Sync Modules). The SM and DSM Sync Modules shall incorporate two inputs from Notification Appliance Cimuits (NACs) for power connection from the Fire Alarm Control Panel (FACP): one for the strobe circuit (NAC), and one for the audible circuit (NAC). A single two-wire output shall control both the audible and visual appliances. Upon activation of the audible silence function of the FACP, the audible signal shall be silenced while maintaining strobe activation. · Sound output at 10 feet (3.048 m) shall be field-selectable for 90, 95, or 99 dBA anechoic for both continuous or temporal (Code 3) tone. The AS Series shall provide listed strobe intensities of 15, 15/75, 30, 75, and 110 candela for wall-mount and/or 75 or 100 candela for ceiling-mount applications; with a flash rate of one flash per second minimum across the listed voltage range. The strobe shall incorporate a Xenon® flashtube enclosed in a rugged LEXAN® lens. The maximum allowable current at 24 VDC shall be 87 mA @ 15 cd, 102 mA @ 15/75 cd, 120 mA @ 30 cd, 177 mA @ 75 cd, and 202 mA @ 110 cd. All devices shall incorporate a reduced inrush circuit design. The strobe shall have a horizontal plane. · The Sync Module shall be designed and available in two versions: the SM-12/24, for control of a single Class "B" NAC circuit; and a dual-output version, the DSM-12/24, for control of either a single Class "A" or two Class ~B" NAC circuits. The DSM dual-circuit version shall provide the additional capability of "daisy-chaining," i.e., the ability to interconnect multiple DSM's for synchronous horn and strobe operation on multiple NAC circuits. DSM-12/24 interconnection capability shall be for a maximum of 20 modules (40 Class "B" NAC circuits or 20 Class "A" NAC circuits). Rated average current requirement for the SM-12/24 shall be 0.014 amperes @ 12 VDC and 0.025 amperes @ 24 VDC; the DSM-12/24 shall be 0.020 amperes @ 12 VDC and 0.038 amperes @ 24 VDC. The SM Sync Module shall be capable of handling a three-ampere load at 12 or 24 VDC. The DSM Sync Modules shall be capable of handling a load of three amperes per circuit in the Class =B" mode, and three amperes per module in the Class "A" mode at 12 or 24 VDC. · SM or DSM Sync Modules and AS Audible Strobes shall be designed as a system for continuous activation of the strobes should the Sync Module contacts fail in the passive state (i.e., contacts remain closed). In this default mode, the strobes shall revert to a non- synchronized default flash rate. · AS/AH Series devices shall be designed for operation at 12 or 24 VDC, over their respective listed voltage ranges of 10.5 to 15.6 VDC; and 20.0 to 31.0 VDC. The units shall be designed for operation on filtered DC, or unfiltered VRMS. Rated average current for AS Series devices shall depend upon voltage and strobe intensity; current shall be es Iow as 0.058 amperes for 24 VDC versions and 0.145 amperes for 12 VDC versions. Rated average current for AH Series devices (volume set at high-dB output) shall be 0.041 amperes for 24 VDC versions and 0.113 amperes for 12 VDC versions. · All versions shall be polarized for DC supervision and shall incorporate screw terminals for in/out field wiring of size #18 AWG (0.75 mm2) to #12 AWG (3.25 mm2). · AS/AH shall incorporate a patented Universal Mounting Plate which shall allow mounting to single-gang, double-gang, 4" (10.16 cm) square, 100 mm European backboxes or Whealock's SHBB surface backbox. No additional trim plate shall be required for flush mounting. · Dimensions for AS/AH appliances shall be 4.625" (11.7475 cm) square by 1.5" (3.81 cm) deep. Due to continuous development of products offered by Wheelock, specifications and product availability are subject to change without notice in accordance with Wheelock standard terms and conditions. Page 4 of 4 .-- DF-51898 Wheelock RS Ser~es Strobes and :-' :~'Ll/~® ~'~l'C~l/I I I~'~ RSS Series Non-Sync/Sync Strobes Section: AudioNisual Devices State Fire Wheelock's new RS Series Strobes and RSS Series Marshal Non-Sync/Sync Strobes offer Iow current draw and re- duced inrush while maintaining their outstanding per[or- 7125-0785:133 mance, reliability, and cost-effectiveness. They meet or LISTED cs 356 7125-0785:141 exceed the latest requirements of NFPA 72 (National Fire S5391 CS 243 Alarm Code 1996), ANSI 117.1 (National Standard for Accessible and Usable Buildings and Facilities) and UL M E~A Standard 1971 (Signaling Devices for the Headng Im- 151-92-E 0D7A4.AY paired). RS/RSS Strobe appliances, when propedy speci- Vol. XIX, XX fled and installed in accordance with NFPA/ANSI stan- dards, can provide the Equivalent Facilitation allowed un- der ADA Accessibility Guidelines (ADAAG General Sec- tion 2.2) by meeting or exceeding the illumination which results from the ADA's strobe intensity guidelines of 75 candela at 50 feet (15.24 m). This is an illumination of 0.030 lumens per square foot. Wheelock's RS Series Strobes are available with 15 and 15/75 candela intensities for wall-mounting only and non- sync applications. Wheelock's RSS Series Strobes include non-sync and sync functions in one appliance. The SM or DSM Sync Module must be used to achieve synchronization of the strobe. Synchronized strobes can eliminate possible re- WM3T strictions on the number of strobes in field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosen- sitive epilepsy. The strobe options for the RSS Series are 15, 15/75, 30, 75, and 110 candela intensities for wall ~ ..... mounting; and 15, 30, 75, and 100 candela intensities for ~ . ceiling-mount applications. ~"-- ~ ~' ' i All strobes use a Xenon flashtube enclosed in a rugged ' ~ LEXAN® lens to provide maximum reliability for effective '~ ' -- ~'. visual signaling. Wheelock's RS/RSS Series Strobes employ an integral Strobe Mounting Plate (patent pending) that makes it easy to mount to a variety of backboxes. The strobes can be / mounted to single-gang, double-gang, 4" (10.16 cm) square, 100 mm European, or the SHBB surface backbox. If the flush backbox has side or top space between it and ~'~ the finished wall, the new NA TP (Notification Appliance " Trim Plate) may be used. It provides an additional 0.65" Plate (16.51 mm) of trim for the appliance. An attractive cover plate is provided for a clean, finished appearance on all retrofit models, cd and are designed for surface mounting indoors or out- doors. "Not to be used as an indoor visual evacuation ~tVM3T ~ Since the inception of UL'1971, strobes signal or for the hearing impaired." Only 88 milliamps, cannot be listed for outdoor use. Wheelock offers WM3T 21 - 31 VDC. strobes for outdoor installations requiring weatherproof appliances and private mode operation where UL 1971 LEXAN® is a registered trademark of GE Plastics, a subsidiary strobes are not required. They are UL 1638 listed at 117 of General Electric Company. This document is not intended to be used for installation purposes. We t~J to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all ISO requirements. All specifications are subject to change without notice. For more information, contact File. Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627- 3473, To~l Free FAX: (877) 69g-4105, FAX Back:(888) 388-3299 WEB: www.firelite.com I~1~!1~ DF-51780 -- Page I of 4 COMMON FEATURr~ · 15/75 candela, Iow-current-draw, wall-mounting strobes are listed at 15 candela under UL 1971 and meet 75 candela · ADA/NFPAJANSI compliant. Meets OSHA 29, Part 1910.165. intensify on-axis for ADA guidelines. · Low current. · Ceiling-mounting RSS available in 15, 30, 75, and 100 can- , Strobe mounting plate (patent pending) for single-gang, dela intensities. double-gang, 4" (10.16 cm) square, or 100 mm European backboxes. Whselock's SHBB shallow backbox is used GENERjI~'_l- NO~'E~ forsurface mounting. · Strobes are designed to flash at 1 flash per second mini- * Low current draw with temperature compensation to reduce mum from 20 to 31 VDC for 24 VDC models; or 10.5 to 15.6 power consumption and wiring costs. VDC for 12 VDC models. Note that NFPA-72 (1996) speci- · Polarized 12 and 24 VDC models with wide listed voltage fiesa flash rate of I to 2flashes persecond and ADAguide- ranges using filtered DC or unfiltered VRM$ input voltage, lines specify a flash rate of 1 to 3 flashes per second. · Fast installation with In/Out screw terminals using #12 AWG · All candela ratings represent minimum effective strobe in- (3.25 mmv) to #18 AWG (0.75 mm2) wires, tensity based on UL 1971. R~ Series Features: · RS/RSS Series strobe products are listed under UL 1971 for indoor use with a temperature range of 32°F to 120°F · 24 volt models only. (0°C to 49°C). · Wall-mounting models only. · The WM3T strobe is listed under UL 1638 for outdoor use · Available in 15 and 15/75 candela intensities only. with a temperature range of -31°F to 150°F (-35°C to 66°C), · Non-Sync application only. maximum humidity of 95%. RSS Series Features: /~WARNINGI? PLEASE READ THESE SPECIFICATIONS AND INSTALLA- · Both non-sync and synchronized function in one appliance. TION INSTRUCTIONS CAREFULLY BEFORE USING, SPECI- To achieve synchronization, a SM or DSM Sync Module must FYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY be used, WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS · Reduced inrush. AND WARNINGS COULD RESULT IN IMPROPER APPLICA- · 12- or 24-voit models. TION, INSTALLATION AND/OR OPERATION OF THESE PROD- · Wall-mounting RSS available in 15, 15/75, 30, 75, and 110 UCTS IN AN EMERGENCY SITUATION, WHICH COULD RE- candela intensities. SULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. ORDERING INFORMATION Model Number* Input Voltage Strobe Average Current** (Amps) @: Mounting Ol~ons*** Candela 20 VDC 24 VDC 31 VDC RS-2415W-FR 24 VDC 15 0.060 0.050 0.043 B, D, E, F, G, H, J, N, O, FI, X RS-241575W-FR 24 VDC 15/75 0.076 0.065 0.052 B, D, E, F, G, H, J, N, O, R, X RSS-2415W-FR 24VDC 15 0.060 0.050 0.043 B, D, ,E, F, G, H, J, N, O, R, X RSS-241575W-FR 24 VDC 15/75 0.076 0.065 0.052 B, D, E, F, G, H, J, N, O, R, X WALL-MOUNT RSS-2430W-FR 24 VDC 30 0.095 0.081 0.066 B, D, E, F, G, H, J, N, O, R, X STROBES Series RS/RSS RSS-2475W-FR 24 VDC 75 0.157 0.133 0.108 B, D, E, F, G, H, J, N, O, R, X RSS-24110W-FR 24 VDC 110 0.199 0.161 0.131 B, D, E, F, G, H, J, N, O, R, X 10.SVDC 12VDC 15.6VDC RSS-1215W-FR 12 VDC I 15 0.148 0.126 0.102 B, D, E, F, G, H, J, N, O, R, X RSS-121575W-FR 12 VDCI 1575 0.189 0.161 0.130 B, D, E, F, G, H, J, N, O, R, X 20 VDC 24 VDC 3t VDC RSS-2415C-FW 24 VDC 15 0.078 0.067 0.055 B, D, E, F, G, H, J, N, X CElUNG-MOUNT RSS-2430C-FW 24 VDC 30 0.120 0.102 0.085 B, D, E, F, G, H, J, N, X STROBES Series RSS RSS-2475C-FW 24 VDC 75 0.247 0.204 0.157 B, D, E, F, G, H, J, N, X RSS-24100C-FW 24 VDC 100 0.285 0.238 0.190 B, D, E, F, G, H, J, N, X 117 cd STROBE WM3T-24-VFR 24 VDC 117 0.088 J, K Indoor/Outdoor NOTE: WM3T-24-VFR UL 1638 only. Refer to Wheelock installa§on instrucifons #P82037. DSM-12/24-R 12 VDC / 24 VDC I 0.020 (12) / 0.038 (24) W NOTES: 1) SUFFIXES USED ABOVE: W = Wall mounting; C = Ceiling mounting; F = Fire lettering; R at end = Red; W at end = White. EXAMPLES: RS-2415W-FR (Wall mounting -Eire lettering, Red); RSS-2415C-FW (.~.eiling mounting -Eire lettering; White). 2) SPECIAL PLATE: NATP Trim Plate provides 0.65' (16.51 mm) additional trim for the appliance. Available in red only. · Series RS and RSS wall-mount models are offered in red only. Series RSS ceiling-mount models are offered in wh/te only, · * Average currant per actual Wheelock Production testing @ 10.5, 12, 15.6, 20, 24 and 31 VDC. For rated average and peak current across the UL listed voltage range for both filtered DC and full-wave-rectified (FWR), see the installation instructions (Wheelock #P83500 for wall-mount and #P83501 for ceiling-mount). · ** For descriptions of MOUNTING OPTIONS, refer to Fire. Lite data sheet DF-51744, derived from Wheelock #S7000. .... SM Sync Modules are rated for 3.0 amperes at 12/24 VDC; DSM Sync Modules are rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to installation instructions for SM (Wheelock #P83123) and DSM (Wheelock #P83177). Page 2 of 4 ~ DF-51780 FEATURES QUICK REFERENCE SYNCS ~ S3ROI3E 24 VDC 12 VDC VVN.I. CEIUNG NON-SYNC MOl:EL NUMBER MOUNT MOUNT SM or DSM CANOELA RED WriTE RS-2415W-FR X X 15 X X RS-241575W-FR X X 15/75 X X RSS-2415W-FR X X X 15 X X RSS-241575W-FR X X X 15/75 X X RSS-2430W-FR X X X 30 X X RSS-2475W-FR X X X 75 X X RSS-24110W-FR X X X 110 X X RSS-1215W-FR X X X 15 X X RSS-121575W-FR X X X 15/75 X X RSS-2415C-FW X X X 15 X X RSS-2430C-FW X X X 30 X X RSS-2475C-FW X X X 75 X X RSS-24100C-FW X X X 100 X X WIRING DIAGRAMS RSS devices synchronized with SM Module single Class "B" (Style Y) circuit WITH audible silence feature. RSS device non-synchronized. ~ From SM DEVICE DEVICE STROBE or FACP or EOLR SIGNAL CIRCUIT ® - STROBE ®/+ OUT  ,- OUT i ~+ AUDIBLE * EOLR VALUE RSS devices synchronized with DSM Module AUDIBLE DETERMINED EOLR* dual Class "A" (Style Z) circuit with SIGNALClRCUIT ~ BY FACP NO audible silence feature. / ~ - AUD BLE NAC CIRCUIT(S). L DSM ® SYNC + RSS devices synchronized (~ SYNC- with multiple DSM Modules. ~+ OUT 1 INTERCONNECTING WIRING SHOWN. ~+INI '"'® - AUDIBLE I IAUDIBLE ~'MINUS 2 I I NAC DSM #2 AUDIBLE NAC ®+ IN 2 CIRCUIT RETURN I SYNC+ I ICIRCUIT SYNC- I IAUDIBLE For details on using SM or DSM Sync Modules, t I NAC DSM #3 or Wheelock installation instructions #P83123 (for SM) or #P83177 (for DSM). I [ STROBE A SYNC + I I NAC I [CIRCUIT SYNC- DF-51780 -- Page 3 of 4 /~WARNINGlV CONTACT WHEELOCK FOR CURRENT "INSTALLATION INSTRUCTIONS" (Wheelock #P83500 for wall-mount and #P83501 for ceiling-mount) AND "GENERAL INFORMATION" SHEET (Wheelock #P82380} ON THESE PRODUCTS. THESE MATERI- ALS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: · TOTAL CURRENT REQUIRED BY ALL DEVICES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. · FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL DEVICES ON THOSE CIRCUITS. · COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. · VOLTAGE APPLIED: THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. · INSTALLATION OF 110/100 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. · INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. · Note: USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF, AS THE STROBE MAY NOT FLASH. · CONDUCTOR SPECIFICATIONS: CONDUCTOR SIZE (AWG), LENGTH AND CAPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUA- TION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal, and other applicable building and fire standards, guidelines, regulations, laws, and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). ARCHITECTS' AND ENGINEERS' SPECIFICATIONS The visual notification appliances shall be Wheelock RS or RSS Series Strobe Appliances, or approved equivalents. RS/RSS Series shall meet and be listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired for indoor fire protection service). The strobes shall be listed for indoor use only. All strobes shall be certified to meet FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second minimum over the listed voltage range of 20 to 31 VDC for 24-volt models, and 10.5 to 15.6 VDC for 12-volt models. All inputs shall be polarized for compatibility with standard reverse-polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). All visual appliances shall incorporate a Xenon flashtube enclosed in a rugged LEXAN~ lens. The RS and RSS Series Strobes shall be of Iow-current design and the RSS shall have reduced inrush. The strobe intensity shall be rated per UL 1971 for 15, 15/75, 30, 75, and 110 candela for wall-mount; and 15, 30, 75, and 100 candela for ceiling-mount applications for the RSS Series; and 15 and 15/75 candela wall-mount for RS Series public-mode installations. The 15/ 75 candela strobe shall be specified when 15 candela UL 1971 listing with 75 candela intensity on-axis is required (e.g., ADA compliance). RSS Series appliances shall incorporate circuitry for synchronized strobe flash and shall be designed for compatibility with Wheelock SM and DSM Series Sync Modules. The strobes shall not drift out of synchronization at any time during operation. If the sync module fails to operate (i.e., contacts remain closed), the strobes shall revert to a non-synchronized flash rate. The visual appliances shall be designed for indoor surface or flush mounting. RS and RSS Series models shall employ a patent pending Strobe Mounting Plate that shall allow mounting to single-gang, double-gang, 4" (10.16 cm) square, 100 mm European-type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trim Plate) shall be provided. An attaching cover plate shall be provided to give the appliance an attractive appearance. The aesthetic appearance shall not have any mounting holes or screw heads visible when the Installation is completed. For outdoor installations, the strobe appliance shall be the Wheelock WM3T. The WM3T shall meet and be listed under UL 1638 (Private Mode Emergency and Utility Signaling). "NOT TO BE USED AS AN INDOOR VISUAL EVACUATION SIGNAL OR FOR THE HEARING IMPAIRED." The WM3T shall be mounted to a weather-resistant backbox, either the Wheelock WBB box or approved equivalent, when mounted outdoors. The WM3T strobes shall produce a flash rate of one (1) flash per second minimum over the listed voltage range of 20 to 31 VDC for 24-volt models. The strobe intensity shall bo rated at 117 candela. Due to continuous development of products offered by Wheelock, specifications and product availability are subject to change without notice in accordance with Wheelock standard terms and conditions. Page 4 of 4 -- DF-51780 I( July 14, 2004 DF-52385 · E-710 H355 (A) Series Fire-LiTe'ALarms Intelligent Addressable Thermal (Heat) Detectors for MS-9600, MS-9200UD www. fJrelJte.¢om Section: Addressable Devices GENERAL ~ (~ ~California The Fire,Lite Alarm H355 Series thermal detectors are ad- State Fire dressable sensors that use a state-of-the-art thermistor Marshal sensing circuit for fast response. These sensors are de- 7270-0075:195 signed to provide open-area protection and are intended LISTED for use with FireoLite's MS-9600 and MS-9200UD Fire Alarm Control Panels (FACPs). S2517 Both the H355 and H355R sensors provide fixed tempera- ture alarm detection at 135°F. The H355R sensor responds APPR0VB] to rate-of-rise conditions of greater than 15°F/8.3°C per minute. H355HT provides fixed high-temperature detection at 190°F/88°C. These thermal detectors provide cost ef- fective, addressable property protection in a variety of ap- plications. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (PiN RA400Z). ~.~ ~ [~111~1~ '~' ~"'6936phol.jp~ FEATURES SLC loop: H355 in B350LP base · Two-wire SLC loop connection. - Unit uses base for wiring. Addressing: - Plugs into separate base for ease of installation and · Addressable by device, maintenance. · Direct Decade 01 - 159 (MS-9600), or 01 - 99 (MS- · Separate base allows interchange of photoelectric, ion- 9200UD) entry of address, ization and thermal sensors. Architecture: Other system features: · Sleek, Iow-profile, stylish design. · Remote test feature from the panel. · State-of-the-art thermistor technology for fast response, o Walk test with address display. · Integral communications and built-in device-type idenfi- · Low standby current. flcation. · 94-5V plastic flammability rating. · Built-in tamper resistant feature. Options: · Built-in functional test switch activated by external mag- - Remote LED output connection to optional RA400Z re- net. mote LED annunciator. Operation: - Recessed (RMK400) or surface (SMK400) base mount- - Factory preset at 135°F (57°C). lng kits. · Rate-of-rise model (H355R), 15°F (8.3°C) per minute. APPLICATIONS · 360°-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink green in Normal condi- Use thermal detectors for protection of property. tion and tum on steady red in Alarm. CONSTRUCTION · Visible LEDs 'blink" every time the unit is addressed. These detectors are constructed of off-white Bayblend®. Mechanicals: The H355 Series plug-in intelligent thermal detectom are · Sealed against back pressure, designed to commercial standards and offer an attractive · SEMS screws for wiring of the separate base. appearance. · Designed for direct-surface or electrical-box mounting. Bayblend® is a registered trademark of Bayer Corporation. IFire'Lite~) Alarrns is a HOneywell c°mpany' This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. ~1~ ~'~~ Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. DF-52385 · 07/14/04 -- Page 1 of z INSTALLATION PRODUCT LINE INFORMATION H355 Series plug-in intelligent thermal detectom use a de- NOTE: 'A' suffix indicates ULC-Listed model. tachable base to simplify installation, service and mainte- H355 Intelligent thermal sensor (B350LP base in- nance. Installation instructions are shipped with each de- cluded). rector. H355A Same as H355 but with ULC Listing (B350LPA Mount base (all base types) on box that is at least 1.5' base included). (3.81 cra) deep. Suitable boxes include: H355R Same as H355 with rate-of-rise feature · 4.0" (10.16 cra) square box. (B350LP base included). · 3.5" (8.89 cra) or 4.0" (10.16 cm) octagonal box. H355RA Same as H355R butwith ULC Listing (B350LPA · Single-gang box (except relay or isolator base), base/ncluded). NOTE: Because of the inherent supervision prevfcled by the SLC H355HT Intelligent high-temperature thermal detector loop, end-of-line resistors are not required. Widng "T-taps" or (B350LP base included). branches are permi~ed for Style 4 (Class aB") wiring only. H355HTA Same as H355HT but with ULC Listing OPERATION (BaSOLPA base included). Each H355 Series detector uses one of 159 (MS-9600) or RA400Z(A) Remote LED. Mounts to a single-gang box. 99 (MS-9200UD) possible addresses on a control panel B350LP(A) Plug-in detector base (included). Dimen- SLC loop. It responds to regular polls from the control panel sions: 6.1" (15.5 cra). Mounting: 4.0" (10,16 and reports its type and the status. If it receives a test com- cm) square box with or without plastic ring, mand from the panel (or a Iocel magnet test), it stimulates 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) its electronics and reports an alarm. It blinks its LEDs when octagonal box, or single-gang box. All mount- polled and tums the LEDs on when commanded by the lng boxes have a minimum depth of 1.5" (3.81 panel. The H355 Sedes offers features and performance cm). that represent the latest in thermal detector technology. M02-04-00 Test magnet. SPECIFICATIONS B224RB(A) Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4,0" Diameter: 6,1" (15.5 cm)installed in B350LP, (10.16 cm) square box with or without plastic Height: 2.1" (5.33 cra), ring, 4.0" (10.16 cra) octagonal box, or 3.5" Weight: 4.8 oz. (137 g). (8.89 cm) octagonal box. Ail mounting boxes Installation temperature: -4°F to 100°F (-20°C to 38°C), have a minimum depth of 1.5" (3,81 cra). Humidity range: 10% to 93% relative humidity (non-con- B224BI(A): Intelligent isolator base. Isolates SLC from densing), loop shorts, Voltage range: 15 to 32 VDC peak. BS01BH(A) Plug-in System Sensor sounder detector base. Diameter: 6.0" (15.24 crn). Mounting: Standby current: 300 pA @ 24 VDC (one communication 4.0" (10.16 cm) square box with or without every 5 seconds with LED blink enabled), plastic ring. Mounting box has a minimum LED current: 6.5 mA @ 24 VDC. depth of 1.5" (3.81 cra). Mounting: B350LP flanged base, included. BS01BHT(A) Same as B501BH(A), but includes temporal Fixed-temperature setpoint: 135°F (57°C). sounder. Rate-of-rise detection: responds to greater than 15°F/ Accessories: 8.3°C per minute, RA400Z(A) Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. For use with BSOI(A) and B350LP(A) bases only. SMK400 Surface mounting kit provides for entry of surface wiring conduit. For use with BSOI(A) base only. RMK400 Recessed mounting kit. For use with B5OI (A) base only. M02-04-01 Test magnet. XR-2 Detector removal tool. Allows installation and/ or removal of detector heads from bases in high ceiling applications. XP-4 Extension pole for XR-2. Comes in three 5-ff. (1,524 m) sections. Page 2 of 2 -- DF-52385 - 07/14/04 / FIRE ALARM SYSTEM SUBMITTAL COVER SHEET revised 6.12-02 t. PROTECTED PROPERTY Name: ~ Oo~(--~ 2. INSTALLING/SERVICE ORGANIZATION C-10 Lice~: 3. MONITORING ENTITY ~'-~' .....~, Name: ~Dc~cxtoi:~tt Contact: ~r~O Telephone: ~O ~'~~ ~ ~nification Numar: ~ 4. APPRQV~I'G AUTHORITY Name: Bakersfield Fire Department, Prevention Services Division b. Address: 1715 Chester Avenue. S~lit~ Contact: ~ave A. Weirather or Hal A,g~r . Telephone: (661) 326-3951 Facsimile: (661) ;326-0576 SONITROL SERVICES · intrusion · CCTV · Hold-up/Emergency °Industnal Process Monitoring · F~re/Waterflow ° Fence/Yard Systems · Card Access ° Cellular Backup Visit us at: .www. sonitrolsecurity, com