Loading...
HomeMy WebLinkAboutBUSINESS PLAN (4)~ Td/'I/Ci'fiCi~O~/ 8501 N. MoPac Expressway, Suite 400 Austin, Texas 78759 Phone: (512) 451-6334 ' Fax: (512) 459-1459 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR STEVE UNDERWOOD 900 TRUXTUN AVE., STE. 210 BAKERSFIELD, CA. 93301 Test Date: 09/26/2007 Order Number: 3155161 Dear Regulator, Date Printed and Mailed: 10/09/2007 Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN #26599, MKT 2133 6529 EAST BRUNDAGE LANE BAKERSFIELD, CA. 93307 Testing performed: Dynamic Pressure Source EVR-Stage I Pressure Integrity Drop Tube Liquid Removal tests Stage II pressure decay tests Sincerely, ~ c>~ ~~~ Post•It'"routing request pad 76gq Dawn Kohlmeyer ROUTING - ~~~ Manager, Field Reporting Please REQUEST READ To HANDLE r -'~ l 1 ~e ' e`er ^ APPROVE 'W''-\\ ^• - ~-f'L. and ~.iQ~ ^ FORWARD ^ RETURN ~ ~~ ^~ KEEP OR DISCARD ~~ C ^ REVIEW WITH ME t ~~ t Gars I'I ~/~-(2~ Date ~ t 2D - From ~' SAN JOAQUIN VALLEY AIR POLLUTION CONTROL DISTRICT TP-201.4 Dynamic Back Pressure Source Information FACILITY PARAMETERS GDF Name and Address District Inspector Phase II System Type 7-ELEVEN #26599, MKT 2133 ABSENT Phase II System Type 6529 EAST BRUNDAGE LANE Device Type Used Balance MANOMETER Assist BAKERSFIELD,CA 93307 Hirt Phase I System Type Hasstech Permit # S-2138-1-6 EVR Healy E.O G-70-52 2 Point Other Coaxial Manifolded? YO or N Date of Last Calibration: 02/12/2007 Type of Test: Wet / Dry Leak Check: Pass / Fail Dynamic Back Pressure, Inches H ~J Nozzle Grade Result 40 CFH 60 CFH 80 CFH 1 E.W.4015 ALL .05 .24 .42 PASS 2 E.W. 4015 ALL .09 .25 .55 PASS 3 E.W. 4015 ALL .09 .27 .41 PASS 4 E.W. 4015 ALL .08 .27 .46 PASS Test Conducted By: Test Company: Date of Test: TIMOTHY COULTER Tanknology 09/26/2007 Signature: Confirmation # Tester Certification # ~'~~ 07-8811 T-6037 San. Joaquin Valley Unified Air Pollution Control District ;, ~ Pressure Decay Test TP201.3 Confirmtion. No. Permit No: Site Name: Address: 07-8811 S-2138-1-6 7-ELEVEN #26599, MKT 2133 6529 EAST BRUNDAGE LANE BAKERSFIELD Phone: 661366-4788 Phase I System? EVR / 2 / Coaxial Phase II System? BALANCE / ASSIST /OTHER Total Number of Nozzles: 4 Nozzles for Tank # 1: 4 Nozzles for Tank # 2: 4 Balance "Nozzle End" hoses must be drained prior to test. Testing Company Name: TANKNOLOGY Address: 41785 Enterprise Circle S Suite D Temecula Cp 92590 Phone: (951)676-4060 Tanks Manifolded? Yes Work Order: 3155161 Nozzles for Tank # 3: 4 Nozzles for Tank # 4: Number of hoses over 100m1: 0 Tank Information 1 2 3 4 All 1. Product Grade 87-MAIN 87-SYPHON 91 2. Actual Tank Capacity, gallons 9989 10000 10000 0 29989 3. Gasoline Volume, gallons 7946 7926 3856 0 19728 4. Ullage, (V) gallons (line #2 minus line #3) 2043 2074 6144 0 10261 5. Start Time 0958 1030 1030 6. Initial Test Pressure, inches H2O 2.00 2.00 2.00 7. Pressure after 1 minute, inches H2O 1.95 1.98 1.98 8. Pressure after 2 minutes, inches H2O 1.90 1.95 1.95 9. Pressure after 3 minutes, inches H2O 1.85 1.93 1.93 10. Pressure after 4 minutes, inches H2O 1.90 1.90 11. Pressure after 5 minutes, inches H2O 1.87 1.87 12. Allowable Final Pressure (See table 1A or 16) 1.86 1.86 1.86 13. Pass /Fail PASS Nitrogen introducing point. Phase I vapor coupler or Phase II vapor riser: Phase I / Phase I Record Vapor Coupler Integrity Test Assembly pressure after 1 minute: 2.10 What type of pressure device used : Incline Manometer ~ Mechanical ~ Digital -must do drift tes 7-31-07 Enter Calibration date for pressure device (90 days ). .07 Enter initial tank ullage pressure (Vent if over 0.5 in, w.c. ) 3 Enter flowmeter rate, F (Must be 1 to 5 CFM ). ~= V 3:49 Enter Calculate ullage fill time, t2. 3:17 Enter actual fill-time. [1522] F .00 Enter ending value of drift test (Must be 0.01 in. w.c. or less ). Tester: TIMOTHY COULTER .~-.6~ Signature: Tester ID: T-6037 Test Date: 09/26/2007 San Joaquin Valley Air Pollution Control District TP 201.1 C/D Drop Tube Tests Report Form Permit Number: S-2138-1-6 Site Name: 7-ELEVEN #26599, MKT 2133 Address 6529 EAST BRUNDAGE LANE City BAKERSFIELD Zip93307 •E Test Company: Technician: Test Certification: Calibration Date of Pressure Device •1 TANKNOLOGY. INC. TIMOTHY COULTER 07/31 /2007 Drop Tube Drain Valve and Overfill Prevention Device Pressure Integrity Test ^ Strai ht Dro Tube ^X Overfill Prevention Device Drop Tube Drain Valve Pressure Test Flow Rate 80 ml/min Drop Tube Overfill Prevention Device Tes Flow Rate 200 ml/min "Corrected" Overfill Device Leak Test Result Time to reach 2 Drain Valve Final Time to reach 2 Overfill Leak Final Overfill Minus Equals in. H2O at SOmI Leak Rate' Pressure in. H~ at 200m1 Rate' Pressure Device Leak Rate Drain Valve Leak Rate Corrected Leak rate for Overfill Device Tank: Grade: ml/min in H~ ml/min in H2O ml/min ml/min ml/min 1 87-M 6 SEC 0.00 2.05 122 SEC 0.00 2.05 0.00 0.00 0.00 PASS 2 87-5 7 SEC 0.00 2.05 136 SEC 0.00 2.05 0.00 0.00 0.00 PASS 3 91 5 SEC 0.00 2.05 146 SEC 0.00 2.05 0.00 0.00 0.00 PASS Signature of Technician: Test Date: 09/26/2007 Work order: 3155161 y LIQUID REMOVAL TEST TP CARB 201.6 Testing Results Facility Name: 7-ELEVEN #26599, MKT 2133 Facility Address: 6529 EAST BRUNDAGE LANE, Test Date: 09/26/2007 Test Unit S#: System Type: BALANCE Page 1 Work Order: 3155161 Disp # Grade GPM Wall Fuel Gallons Post Fuel in hose Liquid Removal Pass/ Fail Retention 1 ALL 0.000 0.000 0.000 0.000 0.000 P 2 ALL 0.000 0.000 0.000 0.000 0.000 P 3 ALL 0.000 0.000 0.000 0.000 0.000 P 4 ALL 0.000 0.000 0.000 0.000 0.000 P Technician: Timothy Coulter Signature: ~~~.- TANKNOLOGY 41785 Enterprise Circle S Suite D Temecula CA 92590 (951)676-4060 ~~ s~ , TEST DATE: 09/26/07 CLIENT:7-ELEVEN, INC. SITE DIAGRAM - 7an 8501 N MOPAC EXPRESSWAY, SUITE 400 AUSTIN, TEXAS 78759 (512)451-6334 FAX (512) 459-1459 WORK ORDER NUMBER3155161 SITE:7-ELEVEN#26599, MKT 2133 L8 L2 L4 4 3 STP ~ O OF I REG 1 L7 L5 P/S ~ O O I REG/ ~ SLV L3 L6 2 ~ STP ~ O O I PREM 1 L1 DROPTUBE FLAPPER VALVES N E AIR/ H2O 58 rn~ ~~ i~ 1 1~ 1 ~~ VENTS Printed 10/09/2007 08:28 ACRAMER