HomeMy WebLinkAboutSPRINKLER REPORTUC ONE, LLC 9100 MING AVENUE - ./ ~.::. . .;;f,;`; Design, Installation, Inspection and Repair of Fire Sprinkler Systems C ~? I ~ ~ i ~ .~.__ ~_ ~_ _, ~~ ~ ~G~~P~go~~d dad~~~orr~ p~~of~o~ ~r~o~~ ,\ v DATE: January, 2006 We herewith enclose a copy of an automatic fire sprinkler system check report for the following facility: UC ONE, LLC 9100 Ming Avenue Bakersfield, CA to the party checked below: Owner: ~JC ONE, LLC C/o Premier Management P.O. Box 9116 Bakersfield, CA 93389 Fire Dept: Thank You RLH Fire Protection File: 7298 cc: Bakersfield City Fire Department Fire Prevention Division 900 Truxtun Avenue, Suite 210 Bakersfield, CA 93301 310 30th Street Bakersfield, CA 93301 Voice 661.322.9344 Fax 661.322.6816 License# 777717 .+ '\ ~~~ ~; r=,~;~` \ Design, Installation, Inspection and Repair of Fire Sprinkler Systems z:. ..._..... , ./ ~ ~~ o d~ \i..,_ _ n C§~1,~\Ll~l ~U~~~OG ~OC~'i~G'Gu7i OG'G '~c~GN()f~~C~ ~ C'CO~IC; Y SYSTEM CHECK REPORT FORM WET PIPE SPRINKLER SYSTEMS (Title 19, Sec. 904.5) Facility: UC ONE, LLC Date: 02/03/06 Address: 9100 Ming Ave. MC#: 7298 Bakersfield, CA Reviewer: R. Gentry Notes: 5 Year Service 07/12/2005 FIRE DEPARTMENT CONNECTION YES N/A NO 1. Are fire de artment connections free of obstructions? X 2. Are fire de artment connections in ood condition? X 3. Are cou lin s free and rotate freel ? X 4. Do cla ers move freel and close com letel ? X 5. Are askets in lace and in ood condition? X 6. Are ca sin lace? X 7. Are inlets identified with a si ? X CONTROL VALVES 1. Are control valves free of leaks? X 2. Are control valves secured in o en osition? X 3. Are control valves free of visible or ext. obstruction? X GAUGES 1. Are au es in ood condition? X 2. Are au e valves turned on? X 3. S stem ressure? Record 90 P. S. I. X 4. Su 1 ressure? Record P. S. I. RISER 1. Is riser free of leaks? X 2: Is riser bracin ro erl secured and free of dama e? X 3. Is riser free of visible or exterior dama e? X 4. Water motor and on test satisfacto ? Electric X PIPING I. Is accessible i in free of dama e? X 2. Is i in free of visible or exterior obstructions? X SPRINKLER HEADS 1. Ares rinlcler heads free of leaks and corrosion? X 2. Is all stora eat least 18" below deflectors? X 3. Ares rinklers installed in ro er osition? X 4. Are extra heads and ro er orifice wrench available? X 5. Are extra heads of the ro er size and tem erature? X WATER FLOW TEST Water Pressure City PSI Tank PSI Fire Pump PSI Test Pi a Located Size Pie Pressure Before Flow Press Press. After Riser 2" 90 65 85 l°3 lL. f.~l ~Jn«cy ~[~O~c~c~i~[[OtN 310 30th Street Bakersfield, CA 93301 Voice 661.322.9344 Fax 661.322.6816 License# 777717