IMPRESSED CURRENT CATHODIC MOTECnON CERT1FICA71ON
DATE: ~-/-p.6
Installation Date:
SITE: ,LCkCJtlj' 7 pe6. Mtu't
7/ Lf Ntlef s-t
~k.oi>l(.r.{;/ejc(, ~.
Model" :1jf.~E/~~h/C Sefial tt..!lZ50S
Voltage: '-1/ Amps: ., b
Coun;e~ C. Fine: Lj .
CONTACT:
PHONE:
Hours:. 7?/>r:;; t'f
Adjustment: + I rf)a..r..~-{'
I hereby certify that the minimum System potential requirements for Impressed Current Cathodic
Protedlon:
~ Ha'lfe Been Met
[ 1 Have Not Been Met
for the Syatems referenced abOve: taken In a.CCCHtIance wlttJ the minimum standards of the National
Assocfptfon of Corrosion Engineers, and as done to .comply wlh EPA and State Dln.ctives
~~C~ Lv': lh'b-s1o/
Technician Pertormfng Test
RONALD J. FRAZE
FIRE CHIEF
Gary Hutton,
Senior Deputy Chief
Administration
326-3650
Deputy Chief Dean Clason
Operationsffraining
326-3652
Deputy Chief Kirk Blair
Fire Safety/Prevention Services
326-3653
2101"H" Street
Bakersfield, CA 93301
OFFICE: (661) 326-3941
FAX: (661) 852-2170
RALPH E. HUEY, DIRECTOR
PREVENTION SERVICES
FIRE SAFETY SERVICES. ENVIRONMENTAL SERVICES
900 Truxtun Avenue, Suite 210
Bakersfield, CA 93301
OFFICE: (661) 326-3979
FAX: (661) 852-2171
David Weirather
Fire Plans Examiner
326-3706
Howard H. Wines, III
Hazardous Materials Specialist
326-3649
May 15, 2006
Mr. Harnak S. Sandhu
Lucky 7
714 Niles Street
Bakersfield, Ca 93305
NOTICE OF VIOLATION
& SCHEDULE FOR COMPLIANCE
Re: Failure to Perform ctJSubmit Three Year Cathodic Protection Certification
Dear Mr. Sandhu:
Our records indicate that your three year cathodic protection certification is past
due. If you have performed this test, please forward those results to my attention
immediately. If you haven't performed this test you are in violation of Section
2635 2(a) of the California COde of Regulations, Title 23, Division 3, Chapter 16
Underground Tank Regulations.
"Field-installed cathodic protection systems shall be designed
and certified as adequate by a corrosion specialist. The cathodic
protection system shall be tested by a cathodic protection tester
within 6 months of installation and at least every 3-years
thereafter."
Therefore, prior to June 12, 2006 you will perform the necessary testing as
required by Code. Failure to Comply may result in revocation of your Permit to
Operate.
Again, if you have recently performed this certification test, please forward the
results to my attention and disregard this notice.
Should you have any questions, please feel free to call me at 661-326-3190.
Sincerely,
Ralph E. Huey,
Director of Prevention ServiCes
JLl ~
._./ (i ...' ,~,
~ , ;
. .
. f , .
, .
By:
Steve Underwood,
Fire Prevention Officer
REH/SUldb
ii~~tM~~~~~"
RONALD J. FRAZE
FIRE CHIEF
Gary Hutton,
Senior Deputy Chief
Administration
326-3650
Deputy Chief Dean Clason
()perationsrrrainllng
326-3652
Deputy Chief Kirk Blair
Fire Safety /prevention Services
326-3653
2101 "H" Street
Bakersfield, CA 93301
OFFICE: (661) 326-3941
FAX: (661) 852-2170
, RALPH E. HUEY, DIRECTOR
PREVENTION SERVICES
FIRE SAFETY SERVICES. ENVIRONMENTAL SERVICES
900 Truxtun Avenue, Suite 210
Bakersfield, CA 93301
OFFICE: (661) 326-3979
FAX: (661) 852-2171
David Weirather
Fire Plans Examiner
326-3706
Howard H. Wines, III
Hazardous Materials Specialist
3213-3649
May 17, 2006
Mr. Harnek Sandhu
Lucky 7
714 Niles Street
Bakersfield, CA 93305
NOTICE OF VIOLATION
& SCHEDULE FOR COMPLIANCE
Re: Failed Monitor Certification Report
Dear Mr. Sandhu:
This office has received notificcltion from Rich Environmental of a failed monitor
certification dated, 11-20-06.
Part of your leak detection device is not working properly. In addition, your
system has to be able to run (me monthly leak test report. The required leak test
minimum, per code, is once a month. . You must make sure that your tanks have
enough fuel to perform and pass a leak test
I spoke with Mr. Steve Obert, the technician who tried to conduct this test. I also
have a copy of Monitor Certification Failure Report, dated 04-20-06, and signed
by you that states you underslahd the condition of your equipment. (See
enclosure.)
Having your monitor certified yearly and in working order is a condition of your
Permit to Operate. Therefore; prior to June 1, 2006, you must make the
necessary repairs to your system. Failure to comply may result in revocation of
your Permit to Operate, I spoke with you on Tuesday, May 16, at 9:00 a.m. and
provided you with names of repair technicians.
Should you need additional cohtractors who perform these types of repairs,
please feel free to call me at 661-326-3190.
Sincerely,
Ralph E. Huey,
Director of Prevention Services
. 4." II II ~
~t)t~
.,.,.,/
By: Steve Underwood,
Fire Prevention Officer
REH/SU/db
t:....,..I^""II"^
iir?/~tM ~~~~~~"
RONALD J. FRAZE
FIRE CHIEF
Gary Hutton,
Senior Deputy Chief
Administration
326-3650
Deputy Chief Dean Clason
Operationsffraining
326-3652
Deputy Chief Kirk Blair
Fire Safety/Prevention Services
326-3653
2101 "H" Street
Bakersfield, CA 93301
OFFICE: (661) 326-3941
FAX: (661) 852-2170
RALPH E. HUEY, DIRECTOR
PREVENTION SERVICES
FIRE SAFETY SERVICES. ENVIRONMENTAL SERVICES
900 Truxtun Avenue, Suite 210
Bakersfield, CA 93301
OFFICE: (661) 326-3979
FAX: (661) 852-2171
David Weirather
Fire Plans Examiner
326-3706
Howard H. Wines, III
Hazardous Materials Specialist
326-3649
December 1, 2005
Lucky 7 Deli Mart
714 Niles Street
Bakersfield, CA 93305
FINAL REMINDER NOTICE
RE: Necessary Secondary Containment Testing Requirements by
December 31,2005 of Underground Storage Tank (s) Located at
the Above Stated Address
Dear Valued Customer,
Over the last six months this office has continued to send reminder notices regarding
secondary containment testing.
Code requires that all secondary containment systems must be tested 6 months post
construction and every 36 months there after.
Senate Bill 989 became effective January 1, 2002, section 25284.1 (California
Health & Safety Code) of the new law mandates testing of secondary containment
components upon installation and every 36 months, thereafter, to insure that the
systems are capable of containing releases from the primary containment until they
are detected and removed.
Our records indicate that your facility is due prior to December 31, 2005.
Those sites that have not been tested and have not pulled a permit prior to December 31,
2005, will have their permit to operate revoked.
This office does not wish to take such action, which is why we will continue to send monthly
reminders.
Contractors are already booked several weeks in advance. I urge you to schedule your
testing date as soon as possible to avoid possible revocation of your permit to operate.
Should you have any questions, please feel free to call me at (661) 326-3190.
Sincerely,
RALh~. HUEY, Director of Prevention Services
)1JIi~
Steve Underwood
Fire Prevention Officer
SU:db