Loading...
HomeMy WebLinkAboutBUSINESS PLAN~_ ~~, ~~~ Design, Installation, Inspection and Repair of Fire Sprinkler Systems ~, ~ li ~ c41~3 ~.G'~S~L~~ Cs ~ ~_ ~/ DATE: January, 2006 We herewith enclose a copy of an automatic fire sprinkler system check report for the following facility: Urner's 4110 Wible Road Bakersf d, CA 93313 to the party checked below: Owner: Urner's 4110 Wible Road Bakersfield, CA 93313 Attn: Steve Steiber Fire Dept: Thank You. _ RLH Fire Protection File: 7287 cc: Bakersfield City Fire Department Fire Prevention Division 900 Truxtun Avenue, Suite 200 Bakersfield, CA 93301 310 30th Street Bakersfield, CA 93301 Voice 661.322.9344 Fax 661.322.6816 License# 777717 i \ \ Design, Installation, Inspection and Repair of Fire Sprinkler Systems ,. ~ ' L~~CVI~G~ rC"in]OG'G ?~~K~~J~}7C~ ~~ u ~~~iC~ C3iRaG~C~G'J~O~~r ~, `' SYSTEM CHECK REPORT FORM WET PIPE SPRINKLER SYSTEMS (Title 19, Sec. 904.5) Facility: Urner's Date: 01/24/06 Address: 4110 Wible Road MC#: 7287 Bakersfield, CA 93304 Five Year Service: 07/28/2005 Reviewer: R. Gentry Notes: Wet System FIRE DEPARTMENT CONNECTION YES N/A . NO 1. Are fire de artment connections free of obstructions? X 2. Are fire de artment connections in ood condition? X 3. Are cou lin s free and rotate freel ? X 4. Do cla ers move freel and close com letel ? X 5. Are askets in lace and in ood condition?. X 6. Are ca sin lace? X 7. Are inlets identified with a si ? X CONTROL VALVES 1. Are control valves free of leaks? X 2. Are control valves secured in o en osition? X 3. Are control valves free of visible or ext. obstruction? X GAUGES 1. Are au es in ood condition? X 2. Are au e valves turned on? X 3. S stem ressure? Record 145 P. S. I. X 4. Su 1 ressure? Record P. S. I. X RISER 1. Is riser free of leaks? X 2. Is riser bracin ro erl secured and free of dama e? X 3. Is riser free of visible or exterior dama e? X 4. Water motor and on test satisfacto ? Electric X PIPING 1. Is accessible i in free of dama e? X 2. Is i in free of visible or exterior obstructions? X SPRINKLER HEADS 1. Ares rinkler heads free of leaks and corrosion? X 2. Is all stora eat least 18" below deflectors? X 3. Ares rinklers installed in ro er osition? X 4. Are extra heads and ro er orifice wrench available? X 5. Are extra heads of the ro er size and tem erature? X WATER FLOW TEST Water Pressure City PSI Tank PSI Fire Pump PSI Test Pi a Located Size Pie Pressure t3efore Plow tress tress. aiier Riser 2" 145 50 130 GJ~ [t~ f, ,] Cr' it I~ <~ [`' I>' v ~ cy c~ ~ u o In] ___ __ _ . _. 310 30th Street Bakersfield, CA 93301 Voice 661.322.9344 Fax 661.322.6816 License# 777717 ti ~. _ ~`~, Design, Installation, Inspection and Repair of Fire Sprinkler Systems i ~ .,,. ~ . C3~v~~~s~fEM CHEC'~'~~RM '~~Q~~o{~~C~ ci ~'C~>C~1G '~;:~ WET PIPE SPRINKLER SYSTEMS (Title 19, Sec. 904.5) Facility: Urner's Date: 01/24/06 Address: 4110 Wible Road MC#: 7287 Bakersfield, CA 93304 Reviewer: R. Gentry Notes: Dry System FIRE DEPARTMENT CONNECTION YES N/A NO 1. Are fire de artment connections free of obstructions? X 2. Are fire de artment connections in ood condition? X 3. Are cou lin s free and rotate freel ? X 4. Do cla ers move freel and close com letel ? X 5. Are askets in lace and in ood condition? X 6. Are ca sin lace? X 7. Are inlets identified with a si ? X CONTROL VALVES 1. Are control valves free of leaks? X 2. Are control valves secured in o en osition? X 3. Are control valves free of visible or ext. obstruction? X GAUGES 1. Are au es in ood condition? X 2. Are au e valves turned on? X 3. S stem ressure? Record Air P. S. I. 39 lb. X 4. Su 1 ressure? Record 130 P. S. I. X RISER 1. Is riser free of leaks? X 2. Is riser bracin ro erl secured and free of dama e? X 3. Is riser free of visible or exterior dama e? X 4. Water motor and on test satisfacto ? Electric X PIPING 1. Is accessible i in free of dama e? X 2. Is i in free of visible or exterior obstructions? X SPRINKLER HEADS 1. Ares rinkler heads free of leaks and corrosion? X 2. Is all stora eat least 18" below deflectors? X 3. Ares rinklers installed in ro er osition? X 4. Are extra heads and ro er orifice wrench available? X 5. Are extra heads of the ro er size and tem erature? X WATER FLOW TEST Water Pressure City PSI Tank PSI Fire Pump PSI Test Pi a Located Size Pie Pressure 13etore r tow Press rress. aver Riser 1-1/4" 130 50 130 310 30th Street Bakersfield, CA 93301 Voice 661.322.9344 Fax 661.322.6816 License# 777717 ,/\ .- ~ ~` Design, Installation, Inspection and Repair of Fire Sprinkler Systems ,, - ,__ \\ ~ Ci~~c.~c~s~ftr;h~~ da~~~l~c»c~ ?~4~c~o~~~ ~~odc:: MAINTENANCE REPORT SUPPLEMENT Business Name: Urner's Date: 01/24/06 SYSTEM TYPE: DRY PIPE YES N/A NO 1. Is valve in service and in ood condition? X 2. Is air ressure and rimin water level normal? X 3. Is air com ressor in ood condition? X 4. Were low oints drained durin fall and winter ins ections? X 5. Are uick o enin devices in service? X 6. Has i in been checked for sto a e within ast 10 ears? X 7. Has i in been checked for ro er itch in the ast 5 ears? X 8. Have valves been tri tested satisfactoril ? X 9. Are valves ade uatel rotected from freezin ? X 10. Valve house and heater condition satisfacto ? X Date Dry System Piping was last checked for stoppage Date Dry System Piping was last checked for proper pitch Date Dry Pipe Valve was last trip tested Wet Systems: Number, Make and Model Dry Systems: Number 1 Make and Model 2-1/2" Cent.Vert OPEN SECURED CLOSED SIGN CONTROL VALVES # TYPE YES NO YES NO YES NO YES NO CONDITION Ciry Connection Tank OS&Y X X X Good Pum B-Fl X X X Good Sectional OS&Y X X X Good S stems B-Fl X X X Good COMMENTS: I~ L1~ [~] (~~ ~~ I~ y (~ li' o ~ c~ c~ ~ ~~ o ~ri~ ~.,__W ,__~_.~ ~ ~.._. _ _ :--- .---... _._.. _.... 310 30th Street Bakersfield, CA 93301 Voice 661.322.9344 Fax 661.322.6816 l.icense# 777717 '~`\~\ Desi n, Installation, Ins ection and Re air of Fire S rinkler S stems ' .~ ~.~ 9 P P P Y ~. ~ 5 o f ~~ o ~, c C- ~~["c~Q~~o~~c:- dad ° ~i~o~'c~ ~`R1ca~~~~ ~~c,~c ~•' SYSTEM CHECK REPORT FORM WET PIPE SPRINKLER SYSTEMS (Title 19, Sec. 904.5) Facility: Urner's (Small Building) Date: 01/24/06 Address: 4250 Wible Road MC#: 7287 Bakersfield, CA 93304 Reviewer: R. Gentry Notes: Wet System FIRE DEPARTMENT CONNECTION YES N/A NO I. Are fire de artment connections free of obstructions? X 2. Are fire de artment connections in ood condition? X 3. Are cou lin s free and rotate freel ? X 4. Do cla ers move freel and close com letel ? X 5. Are askets in lace and in ood condition? X 6. Are ca sin lace? X 7. Are inlets identified with a si ? X CONTROL VALVES I. Are control valves free of leaks? X 2. Are control valves secured in o en osition? X 3. Are control valves free of visible or ext.. obstruction? X GAUGES I. Are au es in ood condition? X 2. Are au e valves turned on? X 3. S stem ressure? Record 80 P. S. I.. X 4. Su 1 ressure? Record P. S. I. X RISER 1. Is riser free of leaks? X 2. Is riser bracin ro erl secured and free of dama e? X 3. Is riser free of visible or exterior dama e? X 4. Water motor and on test satisfacto ? Electric X PIPING I. Is accessible i in free of dama e? X 2. Is i in free of visible or exterior obstructions? X SPRINKLER HEADS 1. Ares rinkler heads free of leaks and corrosion? X 2. Is all stora eat least 18" below deflectors? X 3. Ares rinklers installed in ro er osition? X 4. Are extra heads and ro er orifice wrench available? X 5. Are extra heads of the ro er size and tem erature? X WATER FLOW TEST Water Pressure City PSI Tank PSI Fire Pump PSI C:.... D:.... D.~ncenrn RnFnra Flnw Press Press. After 1 GJL [ ~ c L.,~ca wu Riser - - - - 2" 80 50 75 fr3 11_-„ ~nl [~ ~~ i~ c~ 'i~ li' ©~ c~ ~ ~ a ~o~ inl ._ 310 30th Street Bakersfield, CA 93301 Voice 661.322.9344 Fax 661.322.6816 License# 777717 - , ~ ~, '\~ Design, Installation, Inspection and Repair of Fire Sprinkler Systems !i / \ '~ if ,; o ~~~VANCE RE~,~~L,EMENT ~~~~c~~fi'~c~ ~~~c~~~%~~ Business Name: Urner's Date: 01/24/06 SYSTEM TYPE: DRY PIPE YES N/A NO 1. Is valve in service and in ood condition? X 2. Is air ressure and rimin water level normal? X 3. Is air com ressor in ood condition? X 4. Were low oints drained durin fall and winter ins ections? X 5. Are uick o enin devices in service? X 6. Has i in been checked for sto a e within ast 10 ears? X 7. Has i in been checked for ro er itch in the ast 5 ears? X 8. Have valves been tri tested satisfactoril ? X 9. Are valves ade uatel rotected from freezin ? X 10. Valve house and heater condition satisfacto ? X Date Dry System Piping was last checked for stoppage 05/02/2005 Date Dry System Piping was last checked for proper pitch 05/02/2005 Date Dry Pipe Valve was last trip tested Wet Systems: Number, Dry Systems: Number 1 05/02/2005 Make and Model Make and Model 2-1/2" Cent. Vert CLOSED SIGN OP SECU EN RED CONTROL # TY YES NO YES NO YES NO YES NO CONDITION vaLVES PE Ci Connection O.S X X X X Good Tank &Y B-Fly X X X X Good Pum O.S X X X X Good Sectional &Y B-Fly X X X X Good S stems COMMENTS: f; f~f~ f~ii~ry ("~o~c~c~~uoln~ _:..:_ -- __ 310 30th Street Bakersfield, CA 93301 Voice 661.322.9344 Fax 661.322.6816 l.icense# 777717