HomeMy WebLinkAboutREDLIGHTPHOTOENFORCEMENT_NEWSTINEANDSTOCKDALEPG1 i y - .u a w,.. _ ♦ , _ • h _ ..i n. .n. ♦ ...ri A CONDUCTORS CONDUITS BAKERSFIELD GENERAL NOTES 1 ALL CONSTRUCTION PER CALTRANS STANDARD PLANS & SOURCE AWG# 1 N3/4" 6 7 9 1 4 A TERMINATION SPECIFICATIONS (2002). THE LOCATION OF THE NEW PULL POLE 1 CAT5 2 REDFLEX BOXES, POLES, FOUNDATIONS, & CABINETS ARE - - _ _ _ - fi CABINET APPROXIMATIONS & SUBJECT TO RELOCATION TO AVOID POLE 2 CATS 1 1 1 REDFLEX CONFLICT WITH EXISTING TRAFFIC SIGNAL EQUIPMENT, CABINET UNDERGROUND UTILITIES, & ADA RAMPS. FOUR FEET MINIMUM OF CLEAR SIDEWALK AREA REQUIRED AT ALL LOCATIONS. POLE 3 CAT5 2 2 2 REDFLEX - - - - - CABINET 2 LOCATE ALL UNDERGROUND UTILITIES PRIOR TO POLE 4 CAT5 1 1 REDFLEX CABINET CONSTRUCTION. CONTACT DIGALERT AT 1-(800) 422-4133 THREE (3) WORKING DAYS PRIOR TO CONSTRUCTION. TRAFFIC SIGNAL RED REDFLEX PHASE-PHASE 01 & #14 4 4 4 PHASE 07 CABINET 3 ALL EQUIPMENT MUST BE LOCATED WITHIN R.O.W. I I I I Q oewux ( I 1 I I I _ 4" - m aocs wiroooes - I I 4 SIDEWALK PANELS REPLACED MUST BE A MINIMUM OF 5X5. -CITY POWER - - I - - - - TRENCHING THRU S/W IS NOT ALLOWED. CONDUIT SHALL BE I I 1 8 9 _ -CABINET BORED BETWEEN OPENED PANELS OR ENTIRE SIDEWALK I I t- - - - #8 3 3 3 3 REDFLEX 1 8 91 ` PEDESTAL (120V) REDFLEX LOOP REDFLEX REPLACED. 18" I I • ct • LEAD-IN DLC 8 4 CABINET I I O POWER CIRCUIT 1 #10 2 1 POLE 1 5 CONTRACTOR IS REQUIRED TO OBTAIN A CITY OF BAKERSFIELD REDFLEX CABINET) STREET PERMIT AT THE DEVELOPMENT SERVICES BUILDING AT , 0PO1REA t I t t 10' 0 20' POWER CIRCUIT 2 #10 2 2 2 POLE 2 t I t ` 17TH AND CHESTER. cjN REDFLEX CABINET) CONCRETE I 1 raroAnON GROUND ROD J r4> z ie• x roiA waT OAK POWER CIRCUIT-3 J SCALE: 1"=20' (REDFLEX CABINET) #10 2 2 2 POLE 3 ANCHOR OOLTS. 1 GROUND I I ' y POWER CIRCUIT 4 - i _(REDFLEX CABINET) #10 2 2 POLE 4 REDFLEX CABINET FOUNDATION DETAIL i I 75' ~J SOLID BARE BOND #8 1 1 1 1 1 1 1 ALL REDFLE I _ EQUIPMENT I ! i TELCO POINT OF REDFLEX 4~Q SERVICE CAT5 1 CABINET EE 5~ 4 5 1 2 3 5 1 2 3 1 TOTAL NEW CONDUCTORS 5 27 4 4 9 5 5 7 7 3 1 - - - _ ♦ - - - - - _ CONDUIT SIZE (INCHES) 2 3 2 2 2 2 2 2 3 2 2 S TO CKDAL E ---T - 75' • u . 8101 NEW/EXISTING CONDUIT N N N N N N N N E E N 6 6 ~1 ► s~-{:~~~~ o - - - - - POLE SCHEDULE ~3 8 9 16 ~ 11 /-IK ~ _ 4IDIA STD. GALVANIZED N0. NEW/ STEEL PIPE (ASTM A53 TYPE HEIGHT i EXISTING SCH 40 4-1/2" O.D.) i _ O1 REDFLEX 10' N o c 11 _02 REDFLEX 10' N o Z FRANGIBLE BASE CONSTRUCTION NOTES N fi (CASE ALUMINUM OR REDFLEX 10, N r - - - CAST IRON) 14" 01 INSTALL FOUNDATION AND REDFLEX CONTROL CABINET. 4 REDFLEX 10' N (0 SQUARE AT THE BASE INSTALL %"x 8' GROUND ROD AND BOND TO CABINET WITH #8 i I _ _ _ , - - - ~s DOOR • BARE Cu. 07 I - L.E.D. REPLACEMENT SCHEDULE ACCESS ~ 4" CONCRETE CAP SEE CABINET FOUNDATION DETAIL. ' PHASE TYPE AMBER RED I = I 02 CONTRACTOR SHALL TERMINATE ALL POWER CIRCUITS INTO _T - f - 07 12" YES NO koe~ REDFLEX CABINET. 12 0 I SIDEWALK OR 03 INSTALL INLINE FUSE HOLDER ON RED PHASE CONDUCTOR WITH 5 AMP FUSE INSIDE REDFLEX CABINET, TO PROTECT CITY i - - 01 1z" YES NO GROUND TRAFFIC CABINET. 1 , ® INSTALL 40 AMP CIRCUIT BREAKER INTO EXISTING POWER i I z CONDUIT PANEL FOR 120V SUPPLY TO REDFLEX CABINET. I 1 R5 TERMINATE g14 WIRE TO RED PHASE AND NEUTRAL, INSIDE TRAFFIC CA INET. SEE CONDUCTOR SCHEDULE FOR 12 I i o EARTH APPROACHES. i~ LL © INSTALL #5 PULL BOX. E~ r b C3 bC3 CONCRETE FOUNDATION 07 INSTALL LOOPS AND CONDUIT STUBOUT FOR REDFLEX 6 DETECTION. EACH LOOP MUST HAVE A SEPARATE HOME RUN ~m~~. c~ 4 (4) X 36" X 1' DIA AND LOOP LEAD IN CABLE. MAXIMUM 2 LOOPS PER SAWCUT. t 23" MIN. ANCHOR BOLTS (ASTM A-36 OR A-307. REPLACE CITOY LOOPS IFLREQU RED,TTOEDCITYXSTANDARDS. SEE 0- ' - ? ~ ~ 2 81 1 2 • 81 1 LOOP DETAIL AND DRAWING FOR QUANTITY AND LOOP ID#. B.C., POLE BASE ® INSTALL FOUNDATION AND POLE FOR REDFLEX EQUIPMENT. TEMPLATE SEE DRAWING FOR LOCATION. SEE POLE DETAIL. I -J' o , ❑ INSTALL CAMERA AND (2) 250 WATT FLASH ENCLOSURE ON ~ I %0LATM UNE 12-j" IMAGINARY REDFLEX POLE, AIM AT SIGNAL HEADS. LANE UNE FOUNDATION MAY BE BOLT CIRCLE. M1 INSTALL CAMERA AND 500 WATT FLASH ENCLOSURE ON REDFLEX j t I ROUND OR SQUARE. , POLE, AIM AT MONITORED APPROACH. O RED LIGHT CAMERA SYSTEM ,Lom s' ''ec'"^ of T'°`" POLE DETAIL 11 CONDUIT TO BE BORED UNDER ROADWAY. i i SCALE: l"=2' 12 INSTALL AMBER AND RED LEDS, AND MODIFY SIGNAL HEAD IF i NECESSARY, SO SIGNAL HEAD IS VISIBLE TO REDFLEX I CAMERA. SEE LED SCHEDULE. 11' 3.5' LANE UK APPROVAL BY: _h.5'_ 1© CORE DRILL INTO SBC MANHOLE. I I i 4 Twns per RM Lap 11 TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #1 I I 1 (HOT & NEUTRAL). CONNECT TO SOLID BARE BOND GROUND. I I i I RED LIGHT CAMERA SYSTEM REDFLEX TRAFFIC SYSTEMS LOOP DIAGRAM PUBLIC WORKS DIRECTOR DATE I ~ I Q TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #2 I I (HOT & NEUTRAL). CONNECT TO SOLID BARE BOND GROUND. I I 16 TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #3 ! ! I I (HOT & NEUTRAL). CONNECT TO SOLID BARE BOND GROUND. I I I I 17 TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #4 ~I , I C~ I I y * RED LIGHT PHOTO ENFORCEMENT CAMERAS S T PUBLIC WORKS DIRECTOR NnT At NFI]TRAI 1 C(INNFCT T[l snl in RARE RnNn nani iron I u i ~I i * -06 A PRODUCT OF:  J9 of C 1GP ~.T TRAFFIC SWTEMS •Ci y 6407 BRISTOL PKWY, SUITE 100 ^ CULVER CITY, CA 90230 4 Di PH: 310 642 0470 TR FIC ENGINEER REVISIONS REFERENCES PRU4AIED u pONSION a: DATE - - r NUMBER DATE INITIALS - ; R.E.E.NO.Ar REDLIGHT PHOTO ENFORCEMENT DESIGNED BM DESIGNED BM DRAM CD 6,20 ,200+ CHECKED CHECKED NEW S T I N E ROAD & S T O C K D A L E RECOMMENDED RECOMMENDED CITY OF BAKERSFIELD SHEET I OF I DEPARTMENT OF PUBLIC WORKS