Loading...
HomeMy WebLinkAboutREDLIGHTPHOTOENFORCEMENT_WHITELNANDWIBLE_PG1 41 y I 1 , ( I ! wf, 1 I 1 1 CONDUCTORS CONDUITS BAKERSFIELD GENERAL NOTES SOURCE AWG# 4 6 7 1 TERMINATION Al /2\ XI AA 1 ALL CONSTRUCTION PER CALTRANS STANDARD PLANS & - - - - SPECIFICATIONS (2002). THE LOCATION OF THE NEW PULL POLE 1 I CATS 2 2 2 2 CABINET BOXES, POLES, FOUNDATIONS, & CABINETS ARE APPROXIMATIONS & SUBJECT TO RELOCATION TO AVOID POLE 2 CAT5 1 1 1 REDFLEX , CABINET CONFLICT WITH EXISTING TRAFFIC SIGNAL EQUIPMENT, UNDERGROUND UTILITIES, & ADA RAMPS. FOUR FEET MINIMUM POLE 3 CAT5 2 2 2 2 REDFLEX CABINET OF CLEAR SIDEWALK AREA REQUIRED AT ALL LOCATIONS. POLE 4 CAT5 1 1 - 1 REDFLEX CABINET 2 LOCATE ALL UNDERGROUND UTILITIES PRIOR TO I I I I , t___ - , - TRAFFIC SIGNAL CONSTRUCTION. CONTACT DIGALERT AT 1-(800) 422-4133 1 I 1 1 THREE (3) WORKING DAYS PRIOR TO CONSTRUCTION. j I j I • RED/YELLOW 14 6 8 9 16 PHASE-EB WHITE & # CABINET D 6 3 3 REDFLEX SBLT WIBLE 3 ALL EQUIPMENT MUST BE LOCATED WITHIN R.O.W. I I 1 1~ 8 916 4 SIDEWALK PANELS REPLACED MUST BE A MINIMUM OF 5'X5'. I I j I CITY - - - - - , - - - _ - REDFLEX TRENCHING THRU S/W IS NOT ALLOWED. CONDUIT SHALL BE 1 1 I 1 PEDESTAL (120V - #8 3 3 3 CABINET BORED BETWEEN OPENED PANELS OR ENTIRE SIDEWALK REDFLEX LOOP j REDFLEX REPLACED. rTY- nl LEAD-IN DLC 10 6 6 4 4 CABINET POWER Cl?~CUIT 1 T-_--- 10' 0 20'6WE~ Clf~lJlfi 2~- #10 2 2 2 2 POLE 1 5 CONTRACTOR IS REQUIRED TO OBTAIN A CITY OF BAKERSFIELD 1 1 r,-ti ' a, 11 REDFLEX CABINET STREET PERMIT AT THE DEVELOPMENT SERVICES BUILDING AT I i l I , I - T-17TH AND CHESTER. I I I I I I I 1 1 I I I I I I 1 1 I I I I I I I I I I 60' (REDFLEX CABINET) #10 2 2 2 POLE 2 SCALE: 1"=20' _P W I U7T- -3-- - - _ _ . - _ . 1 i i i l i i i1 1 I I t' 1 i i i I i i it I' I I i i (REDFLEX CABINET) #10 2 2 2 2 POLE 3 I I I C ROWER__C11~ U 4 - - - REDFLEX CABINET #10 2 2 2 POLE 4 SOLID BARE BOND #8 1 1 1 1 1 1 1 1 1 ALL REDFLE /AI 11 I 1 I I I I I 1 I I I I I I ~ y- ~ \ NS TELCO POINT OF _ : - - -+EQUIPMENT FLEX I I I I I I I I I 1 1 I I HI TE L A NE C AI-TR A SERVICE CAT5 1 CABINET LJ_J I I' I I I I I ~ ~ 1 LJ-J I TOTAL NEW CONDUCTORS 34 14 11 5 8 8 9 5 4 9 3 3 3 1 _ _ I L J 111 1 - CONDUIT SIZE (INCHES) (2)3 2 2 2 2 2 2 2 2 2 2 2 2 2 • NEW/ EXISTING N EXISTING CONDUIT N N N N N N N N N N E E ---~_-------a+--- r - - ------r==----=------ (J~ 1 , 1POLE SCHEDULE - - - -I 4IDIA STD. GALVANIZED -`-----------°--J ' - - - - NO. TYPE HEIGHT I NEW/ STEEL PIPE (ASTM A53 I 1 - - - 1 - -r EXISTING SCH 40 4-1/2" O.D.) - - 1 REDFLEX 10 N o vi y I r________"_ti r _ ' - - - - - - 2 REDFLEX 10' N o ~ FRANGIBLE BASE v CONSTRUCTION NOTES - - - - _F - ---F-'---'-----'-----~ 3 REDFLEX 10' (CASE ALUMINUM OR N _ CAST IRON 14 r 4 REDFLEX 10' N SQUARE AT THE BASE 01 INSTALL FOUNDATION AND REDFLEX CONTROL CABINET. r - 0 INSTALL x 8 GROUND ROD AND BOND TO CABINET WITH ,#8 ' _ -J 4 -4___________ L.E.D. REPLACEMENT SCHEDULE i ACCESS DOOR BARE Cu. _ PHASE TYPE AMBER RED ~ 4" CONCRETE CAP SEE CABINET FOUNDATION DETAIL. 6 02 CONTRACTOR SHALL TERMINATE ALL POWER CIRCUITS INTO - _ - _ - - - - _ iJ! " - -7-- J i i 8 101 81015 07 12" YES YES - REDFLEX CABINET. I TI 11 , - - , 1rIT m1 2" BALL YES NO SIDEWALK OR ❑3 INSTALL INLINE FUSE HOLDER ON RED PHASE CONDUCTOR WITH " i- - GROUND J 5 AMP FUSE INSIDE REDFLEX CABINET, TO PROTECT CITY - - - - - - - - - TRAFFIC CABINET. r - - - 12 ' ' 1. I HaanON uNE z CONDUIT ®INSTALL 40 AMP CIRCUIT BREAKER INTO EXISTING POWER ' - 7 I _ r Lyt']1 PANEL FOR 120V SUPPLY TO REDFLEX CABINET. 11 LANE uNE Q TERMINATE #14 WIRE TO RED PHASE AND NEUTRAL, INSIDE • 12 j to' - o EARTH TRAFFIC SIGNAL TERMINAL BOX. SEE CONDUCTOR SCHEDULE FOR APPROACHES. 8 914 I 8' CONCRETE FOUNDATION © INSTALL #5 PULL BOX. LOW (4) X 36" X 1 " DIA ❑7 INSTALL LOOPS AND CONDUIT STUBOUT FOR REDFLEX 65' I r or i i S DETECTION. EACH LOOP MUST HAVE A SEPARATE LOOP LEAD IN CABLE. MAXIMUM 4 LOOPS PER SAWCUT. REDFLEX LOOPS i I r-ri 5 1 5_ `A"E ""E 23 MIN. ANCHOR BOLTS (ASTM -c-1 - - -cam - - A-36 OR A-307. TO BE LABELED AT REDFLEX CABINET. REPLACE CITY LOOPS --I- 41 111 8' TO CITY STANDARDS. SEE LOOP DETAIL AND DRAWING FOR 8 1 17 4 ; I ~ 4 run,m yr Rts lao. QUANTITY AND LOOP ID#. RED LIGHT CAMERA SYSTEM ' { B:C•~~ POLE BASE I I 1 1 (I) REDFIEx TRAFFIC SYSTEMS LOOP DIAGRAM TEMPLATE ® INSTALL FOUNDATION AND POLE FOR REDFLEX EQUIPMENT. SEE DRAWING FOR LOCATION. SEE POLE DETAIL. i l l i i i l 1 1 i i i 4 2 4 2 3 Q 12-j" IMAGINARY 09 INSTALL CAMERA AND (2) 250 WATT FLASH ENCLOSURE ON 1 1 i i i 1' 1 i i i 3 REDFLEX POLE, AIM AT SIGNAL HEADS. aDEWAUC FOUNDATION MAY BE BOLT CIRCLE. 10 INSTALL CAMERA AND 500 WATT FLASH ENCLOSURE ON REDFLEX 11J 1 i i 1 I R4" " - se• SM w,rrOM - ROUND OR SQUARE. POLE, AIM AT MONITORED APPROACH. 1J_i I , I RED LIGHT CAMERA SYSTEM 11 CONDUIT TO BE BORED UNDER ROADWAY. Q 18_ POLE DETAIL SCALE: 1"-2' 12 INSTALL AMBER AND RED LEDS, AND MODIFY SIGNAL HEAD IF I I 1 1 1 160' NECESSARY, SO SIGNAL HEAD IS VISIBLE TO REDFLEX I I 1 I I OPEN AREA APPROVAL BY: CAMERA. SEE LED SCHEDULE. I 1 1 I 1 13 STUB OUT INTO SBC VAULT. I I I I I I n ~J I 1 1 t' c~\ CONCRETE -FOUNDAMIN 28(a) x 1e• x DIA GROUND ROD c.M.OAK - 1 TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #1 I 1 I I I ~ AVC (HOT & NEUTRAL). CONNECT TO SOLID BARE BOND GROUND. J I I i l t(IF TNO µ`'O1 t'` / ANCHOR PU WORKS DIRECTOR DATE TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #2 13 (HOT & NEUTRAL). CONNECT TO SOLID BARE BOND GROUND. I I 1 1 GROUND 31 REDFLEX CABINET FOUNDATION DETAIL TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #3 1 I I IN (HOT & NEUTRAL). CONNECT TO SOLID BARE BOND GROUND. I I I Ta V,~1 MLOOM PHOTO WrOOCeYOQCAUIRA+ SISTANT PUBLIC WORKS DIRECTOR D TERMINATE POLE TO REDFLEX CABINET POWER CIRCUIT #4 ~b - ti A PRODUCT OF. (HOT & NFUTRAL). CONNECT TO SOLID BARE BOND GROUND. w ACm LmmV EN LANE CLOSURES WILL BE PERMITTED ON WEEKENDS OR TRAFFIC SYSTEMS WEEKNIGHTS AFTER 8 P.M. 6407 BRISTOL PKWY, SUITE 100 CULVER CITY, CA 90230 - PH: 310 642 0470 TROPIC ENGINEER REVISIONS REFERENCES PREPARED UNDER THE SUF PREPARED UNDER THE SUMMSION OF: DATE NUMBER DATE INITIALS R.E.E. NO. REDLIGHT PHOTO ENFORCEMENT DESONED BM CHECKED DESONIED e" °R"WI" 06'06'200' ofo(m WHITE LANE & WI B LE ROAD CNEam RECOMMENDED RECOMMENDED CITY OF BAKERSFIELD SHES I OF I DEPARTMENT OF PUBLIC WORKS