Loading...
HomeMy WebLinkAboutREDLIGHTENFORCEMENT_bERNADRATOSWELL_CHESTERATBRUNDAGE_COFFEEATTRUXYUN_PG1Y' .F r i r,T 'A"ERS1 ERSF ELD List of Sheets. C TY OF BDD Im 1. Cover Sheet KERN COUNTY, CAL CALO FORK A 2. Chester & Brundage 3. Bernard & Oswell RED L GHT ENFORCEMENT CALM CAMERA NSTALLAT ON 4. Coffee & Tru xtu n ECT ONS OF QT THE O NTERSECT Bernard at 0swe Chester at Brunda tun age and Coffee at TruKtun 9 GENERAL NOTE: CONTRACTOR IS REQUIRED TO OBTAIN A CITY OF BAKERSFILED STREET PERMIT AT THE DEVELOPMENT SERVICES BUILDING AT 17TH AND CHESTER. w~ A Nf LAW A I \ CD m APPROVAL BY: PUB WORT (RECTOR 'DATE APPROVAL RECOMMENDED: Abp T PUBLIC WORKS DIRECTOR * This stamp reflects the modification work as work as outlined. It is not reflective of the 1RA C ENGINEER existing conditions of the depicted intersection :ersection or the past design thereof. ii o DESIGN ENGINE • + ~f ESS lp~ REDFLEX TRAFFIC SYSTEMS S CITY OF BAKERSFIELD, CALIFORNIA Designed B )r EM and JB K Drown By. JB 11-4-02 ~ No. E013216 15020 N. 74TH STREET EV_ 4.ol" Approved Date Recommended Date Scale: NTS SCOTTSDALE, ARIZONA 85260 PH: 480-607-0705 FAX: 480-607-0752 T\ Project No.: 1071 1752 • CAD File No.:1071-015-1V1 RED LIGHT CAMERA ENFORCEMENT Signature Sheet: 1 of 4 I Jrr. n 4i. MOWN CONDUCTORS CONDUITS SOURCE AWG/ Q © z~s &I 7 ® 1 AJAJA © TERMINATION POLE-1 CAT 5 2 2 RTS CABINET POLE-3 CAT 5 1 1 1 1 1 1 1 1 RTS CABINET GENERAL NOTES I ~ I POLE-1 rg STF 1 POLE 2 FLASH UNIT j 1 ALL CONSTRUCTION PER CALTRANS STANDARD :I I PLANS & SPECIFICATIONS (1992). THE LOCATION 19 0 POLE-3 /18 S POLE 4 FLASH UNIT OF THE NEW PULL BOXES, POLES, FOUNDATIONS, TRAFFIC SIGNAL RED PHASE /14 2 2 2 2 RTS CABINET & CABINETS ARE APPROXIMATIONS & SUBJECT TO i RELOCATION TO AVOID CONFLICT WITH EXISTING N ( rI 8 RTS CABINET ' LOOPS (ALL SETS) 1 TRAFFIC SIGNAL EQUIPMENT, UNDERGROUND .6 F J r J J WIRE I W LOOP LEAD Ar (ALL SETS) DLC RTS CABINET ` UTILITIES, & ADA RAMPS. FOUR FEET MINIMUM _ I _ I W CLEAR SIDEWALK AREA IS REQUIRED AT ALL 1 > POWER PEDESTAL (120V) NIA 2 2 2 2 RTS CABINET {f` LOCATIONS. I Q POLE-1 f' Q POKER CIRCUIT 1 RTS CABINET p0 1 1 2 LOCATE ALL UNDERGROUND UTILITIES PRIOR TO eAS`E E I POV0 CIRCUIT 2 RTS CABINET 010 1 POLE-2 CONSTRUCTION. CONTACT DIGALERT AT 1-(800) TVP r, I r, Ir Ir 422-4133 THREE (3) WORKING DAYS PRIOR TO CABINET FOUNDATION DETAIL I I I i I I 1 I POWER CIRCUT 3 RTS CABINET /10 1 1 1 1 1 1 1 1 POLE-3 CONSTRUCTION. r 13 W W 3 ALL EQUIPMENT MUST BE LOCATED WITHIN R.O.W. I I I I I i i II III t P010 CRO1AT 4 RTS CABINET #10 POLE-4 U/ NEUTRAL POWER /10 2 1 1 1 1 1 1 1 1 1 FOLLOW POOR WIRES 4 SIDEWALK PANELS REPLACED MUST BE A MINIMUM I 11 I I W OF 5'X5'. TRENCHING THRU S/W IS NOT ALLOWED. 0 20 40 60 80 I I III II I I 3 , SOLID BARE BOND AB t t t 1 t t t 1 t 1 CONDUIT SHALL BE BORED BETWEEN OPENED I IIII II I I I I r I = 131417 PANELS OR ENTIRE SIDEWALK REPLACED. SCALE 1"=20' I 1 III I II L (J TOTAL NEW CONDUCTORS 7 6 8 8 8 4 4 4 4 4 4 8 i I 1 1 1 1 1 1 CONSTRUCTION NOTES I III i I ► III L L..~ J L OTTER CONDUIT SIZE 2' 2' 2- 2- 2- • • • 1.5' 2- 3' 2- D INSTALL REDFLEX CONTROL CABINET AND - L . - NEW/E%ISTING CONDUIT N N N N E E E E E N E N - FOUNDATION. EXACT LOCATION TO BE DETERMINED BY REDFLEX AND CITY. INSTALL i"X8' GROUND ROD AND BOND TO CABINET WITH #8 BARE Cu. 05 ` 05 V I ____________-.I 02 I------------J CONTRACTOR SHALL TERMINATE ALL POWER ~I CIRCUITS INTO RTS CABINET. - - - - - + INSTALL SPADE LUG & TERMINATE TO SIGNAL HEAD B R U N D A G E LANE 7 I FOR RED PHASE & NEUTRAL. INSTALL INLINE FUSE - - L~ HOLDER ON RED PHASE CONDUCTOR WITH 5 AMP r - - - - - - - - - - - J I ti- FUSE INSIDE REDFLEX CABINET. L - _ _ - _ I® INSTALL 40 AMP BREAKER INTO EXISTING CITY MEYER 1 I~ PEDESTAL FOR 120V SUPPLY TO RTS CABINET - _ - - - -J I TERMINATE #14 RED PHASE AND NEUTRAL INTO F - TRAFFIC SIGNAL BLOCK GIVING REDFLEX RED PHASE L - - - - _ _ _ - _ _ _ J - - FOR N.B CHESTER AVENUE. _ -7 13L 13L 13L 13L T ` INSTALL SOLID STATE RELAYS INTO CITY CABINET - - - - - _ - - 6 TO PROTECT CITY RED PHASE. 141516 _ I -I ~a I dl 1 Ji'~ a Direction of Travel Q7 INSTALL NO. 5 PULL BOX. I Stop N1a t 2 3 i LANE LINE ® INSTALL FOUR NEW 3ox8' ENFORCEMENT LOOPS PER I i CONFIGURATION DETAIL. EACH LOOP MUST HAVE A -TI I I I '1j 1 T~ -1 I I I 1 ReOu loops SEPARATE HOME RUN AND LOOP LEAD-IN CABLE. 1 III 11 l1 ~1111 11111 I I II II II II I I II II III II III I i O r---------------~ I I II II II II I I r I II I~ I~ I II ~II II III II III I I , 8~I I I RECUT L" W I I F I I Ii- - I 1+ -N I , I I I 12 16 RECUT CITY LOOP 8' CITY 90 INSTALL TWO NEW 6'X12' CITY TRAFFIC LOOP (TYPE UI li li Ii C) DETECTORS AND TWO 6'X20' CITY TRAFFIC LOOP 40 MA STD Ui~ 13l I II 13U 13U11 I I ~I I I I DETECTORS (TYPE C). INSTALL 2ND DLC IF NEEDED 10' CALVAN[w Sim 113 PIPE (ASTM AM SCH I 11 I II I III I FOR CONNECTION TO SEPARATE DETECTORS 40 +-1/Y OZ.) L JI L J I L- LJI LJI LJI L_J LANIE UNE ASSIGNED IN PLAN VIEW. FRANME INSTALL POLE 10, 65' SOUTH OF VIOLATION LINE, ALU&NNUhl ORRCCAST~) I I I _ ~ O 20' Y 3' 3' 3' 2' 12' AND 30„ FROM FACE OF CURB. EXACT LOCATION I I I ~ ~ 10 11 15 TO BE DETERMINED BY REDFLEX AND CITY. 20 (IFM ALMXDING UMWUM PAM cAS~ET RED SYSTEM 11 INSTALL CAMERA ENCLOSURE, SCENE FLASH UNIT GROW LINE SDEWAUC oR ISLAND I _ REDFLEX TRAFFIC SYSTEMS Date 10r4ro2TA AND ARM ON POLE 1 . 17\ 77777 1 LJI L. LJI L J I L J Drano by CH LOOP OIAM M - (Strout thm* Lan) 12 INSTALL PLATE FLASH UNIT POLE 20 30' SOUTH OF I I I VIOLATION LINE. LENGTH 4 36- REQUIRED BY i , . I Q~ffESS/ REV. F DESCRIPTION CK'D APP DATE INSTALL POLE (3 JUST NORTH OF GUTTERT 30 MIN MANUFACTURER i : "C PUBLIC WORKS DEPARTMENT ENGINEERING DIVISION FROM FACE OF CURB. EXACT LOCATION TO BE r'x6•xr /A * This stamp reflects the modification work 21 N0 B A K E R S E I E L_ D CA DETERMINED BY REDFLEX AND CITY. as outlined. It is not reflective of the Ev- No. E01 0 ® INSTALL CAMERA ENCLOSURE, FACE FLASH UNIT, / . , _ AND ARM ON POLEO3 existing conditions of the depicted TRH' RED LIGHT ENFORCEMENT intersection or the past design thereof. ~ F~I TERMINATE TO POWER CIRCUIT #1 (HOT AND NEUTRAL) - . CHESTER & BRUNDAGE I-- ~ ~ 10 aA ANCHOR ears (4)x36' g TERMINATE TO POWER CIRCUIT #2 (HOT AND NEUTRAL) TOP 4 OF ATE (ASTM) A-36 OR A-307) POLE DATA FOUNDATION SHALL BE F)aSTING F WW OR REDFLEX TRAFFIC SYSTEMS WBr: JB DES BY: EM M. BY: RSW OGHT F]aSDNG TERMINATE TO POWER CIRCUIT #3 (HOT AND NEUTRAL) SQUARE. RE"AINING r 12-3/4• BOLT CIRCLE NO. TYPE HEIGHT NEw OR DEPTH YAY BE ROUND 24-MIN IN C 1 PELCO 10' NEW OR SQUARE. ww 15020 N. 74TH STREET alylwcDOM DAW L t 2 PELCO 10' NEW SCOTTSDALE, ARIZONA 85260 3 PELCO 16 NEW NEw _ PH: 480 607-0705 FAX: 480 607-0752 DOM RU "NFQ " 4 POLE DETAIL RED-LIGHT CAMERA ENFORCEMENT SKGNmo PROJECTNU1U 1071-007-lv3 11-4-02 sw 2 cF 4 FU Na 00-D-76 ii■ 1 I K f 1 CONDUCTORS CONDUITS SOURCE AWG/ A © 4 & 7 ® Ail& TERMINATION GENERAL NOTES POLE-1 CAT 5 2 2 2 2 RTS CABINET 1 ALL CONSTRUCTION PER CALTRANS STANDARD PLANS & SPECIFICATIONS (1992). THE LOCATION ~~~/18•-.~ POLE-3 CAT 5 1 1 1 1 1 RTS CABINET OF THE NEW PULL BOXES, POLES, FOUNDATIONS, & POLE-4 CAT 5 RTS CABINET CABINETS ARE APPROXIMATIONS & SUBJECT TO , RELOCATION TO AVOID CONFLICT WITH EXISTING t POLE-1 /18 S 1 POLE 2 FLASH UNIT TRAFFIC SIGNAL EQUIPMENT, UNDERGROUND " TRAFFIC SIGNAL RED PHASE /14 2 2 2 2 RTS CABINET UTILITIES, & ADA RAMPS. FOUR FEET MINIMUM OF CLEAR SIDEWALK AREA IS REQUIRED AT ALL I LOOPS (ALL SETS) ~ 8 RTS CABINET LOCATIONS. I I I I Loop LEAD IN (ALL SETS) DLC 4 4 RTS CABINET 2 LOCATE ALL UNDERGROUND UTILITIES PRIOR TO BASE I ' I POWER PEDESTAL (120V) /8 2 2 2 2 RTS CABINET CONSTRUCTION. CONTACT DIGALERT AT 1-(800) 0'~ ! ( I (n V / I 422-4133 THREE (3) WORKING DAYS PRIOR TO CABINET FOUNDATION DETAIL POWER CIRCIIT 1 RTS CABINET /10 1 1 1 1 POLE-1 CONSTRUCTION. I r I r - POWER CIRCUIT 2 RTS CABINET /10 1 1 1 POLE-2 3 ALL EQUIPMENT MUST BE LOCATED WITHIN R.O.W. -J I 4 SIDEWALK PANELS REPLACED MUST BE A MINIMUM >W W POWER CIRCUIT 3 RTS CABINET /10 1 1 1 1 1 POLE-3 OF 5'X5'. TRENCHING THRU S/W IS NOT ALLOWED. POWER CIRCUIT 4 RTS CABINET /10 POLE-4 CONDUIT SHALL BE BORED BETWEEN OPENED Cf ~ I 3 NEUTRAL POWER j10 3 2 2 1 1 1 1 FOLLOW POWER MIRES PANELS OR ENTIRE SIDEWALK REPLACED. I t t I t t I t t t t t i t t O 1 ! O - SOLID BARE BOND /B 1 1 1 1 1 1 1 1 t~ ~ ~I t i t t ~ 1314 17 _ -I T O- TOTAL NEW CONDUCTORS CONSTRUCTION NOTES Jt- CONDUIT SIZE 18 11 8 5 5 4 4 3 4 4 4 8 - 30 2' 2• 2• 3• 3• 20 20 30 3- 3• 2- C 0 INSTALL REDFLEX CONTROL CABINET AND - :f C , J Jam, FOUNDATION. EXACT LOCATION TO BE DETERMINED 02 - - - - - -I 05 ti5 02 7 n NEW/EwsTING CONDUIT N N N N E E E N E E E N BY REDFLEX AND CITY. INSTALL h8' GROUND ROD AND BOND TO CABINET WITH #8 BARE Cu. D CCONTRACTO IRCUITS INTOSRTSLC CTERMINATE ABINET. ALL POWER BERNARD S T ` I F3 INSTALL SPADE LUG & TERMINATE TO SIGNAL HEAD - - FOR RED PHASE & NEUTRAL. INSTALL INLINE FUSE - - - _ - - - - - , HOLDER ON RED PHASE CONDUCTOR WITH 5 AMP L - - - - - - - - - t J FUSE INSIDE REDFLEX CABINET. INSTALL 40 AMP BREAKER INTO EXISTING CITY MEYER PEDESTAL FOR 120V SUPPLY TO RTS CABINET DLnctlon of T"nPW - Stop ear TERMINATE #14 RED PHASE AND NEUTRAL INTO L LANE LINE - TRAFFIC SIGNAL BLOCK GIVING REDFLEX RED PHASE - --fix , FOR N.B OSWELL STREET. - - - - - 13L 13L - wens Loopy © INSTALL SOLID STATE RELAYS INTO CITY CABINET -1- -T--1 2 3---------------~ r----- 4 TI I I I r -If IL I 1 6- 1 RECUT CITY LOOP I 8' I OTTY~L~ I TO PROTECT CITY RED PHASE. 9,81 ~I I I 1 I Q7 INSTALL NO. 5 PULL BOX. ❑7 INSTALL FOUR NEW 3'x8' ENFORCEMENT LOOPS PER I t 14 CONFIGURATION DETAIL. EACH LOOP MUST HAVE A I I t t I I r LANE LINE SEPARATE HOME RUN AND LOOP LEAD-IN CABLE. 20' r s r r ,r 09 INSTALL TWO NEW 6'X12 CITY TRAFFIC LOOP (TYPE ii i I ~I I I~ I I J IL- , 1218 C) DETECTORS AND TWO 6'X20' CITY TRAFFIC LOOP kip 40 DU SID I li t I til,'34 DETECTORS (TYPE C). INSTALL 2ND DLC IF NEEDED 10cAwAH~D STEEL lF;3~1~ 1131 L , j iJ I L _1 4 Dc" 10/14/02 RED LIGHT CAMERA SYSTEM I- I REDFLEX TRAFFIC SYSTEMS FOR SEPARATE DETECTORS ASSIGNED IN PLAN VIEW. t~ (MIM AM SCH I JL_~ I I I 1 lO Draw by CH LOOP DIAGRAM - (Strdot Though Low) PO INSTALL POLED, 65' SOUTH OF VIOLATION LINE, 40 4-1/Y O.D.) _ I I ( I AND 30" FROM FACE OF CURB. EXACT LOCATION MMGIBLE BASE M OR CAST W TO BE DETERMINED BY REDFLEX AND CITY. 101'5 * This stamp reflects the modification work 3D' BLIDMIG PAPER GASKET as outlined. It is not reflective of the 11 INSTALL CAMERA ENCLOSURE, SCENE FLASH UNIT 2 (F &umwAI BASE) I I I I AND ARM, ON POLE 1O ` " SIDEW" OR tSLW ~b l I I existing conditions of the depicted 12 INSTALL PLATE FLASH UNIT POLE 20, 30' SOUTH I i I intersection or the past design thereof. OF VIOLATION LINE. 0 20 40 60 80 ESS~Oy4, REV. DESCRIPTION CKb APP DATE O S- wP INSTALL POLE 133 , JUST NORTH OF GUTTER 30" LENGTH As ' j 36'tutN REOLARED BY PUBLIC WORKS DEPARTMENT ENGINEERING DIVISION FROM FACE OF CURB. EXACT LOCATION TO BE MANUFACTURER DETERMINED BY REDFLEX AND CITY. I*xM'X4' SCALE 1"=20' N E013216 CITY OF BAKERSFFIELD Ev. q%O 5 14 INSTALL CAMERA ENCLOSURE, FACE FLASH UNIT, ' AND ARM ON POLE© TRH / RED LIGHT ENFORCEMENT TERMINATE TO POWER CIRCUIT #1 (HOT AND NEUTRAL) u v~v i . v vim, v.~ ♦ ♦ L- Ll_ ~g TERMINATE TO POWER CIRCUIT #2 (HOT AND NEUTRAL) f--24VIN--~ POLE DATA V aA ANCNOR ears (4)x36• TOP C OF CONCRE OR W R E D F L E X TRAFFIC SYSTEMS owe. By. JB DES. BY: EM. By: R SW BE (A51M) A-36 OR A-307) NO. TYPE HEIGHT W ENSTING % *4T r)asTwG 7 TERMINATE TO POWER CIRCUIT #3 (HOT AND NEUTRAL) FounoA110NTE r 12-3/4• BOLT CIRCLE © SQUARE REWAk11NG 1w NEW 15020 N. 74TH STREET pTY PAM EN wo WE DEPTH WAY BE ROUND 1 PELCO 10' NEW 24 MIN . • .C , , OR SQUARE. 2 Paco 10, NEW 1w NEW 3 1UNEW SCOTTSDALE, ARIZONA 85260 L PELOO 10' NEW 4 - - - PH: 480 607-0705 FAX: 480 607-0752 Dow ME " POLE DETAIL RED-LIGHT CAMERA ENFORCEMENT SPEC. MJWKR PRUcTNUM 1071-009-10 11-4-02 SHEET 3 of 4 Fu No. 00-D-76 ~ r y4 rl r CONDUCTORS CONDUITS AYMG/ 1 Q 4 7 AAAAAFA TERMINATION GENERAL NOTES SOURCE POLE-1 CAT 5 2 2 2 2 2 R15 CABINET 1 ALL CONSTRUCTION PER CALTRANS STANDARD PLANS & SPECIFICATIONS (1992). THE LOCATION SCALE POLE-3 CAT 5 1 1 RTS CABINET OF THE NEW PULL BOXES, POLES, FOUNDATIONS, & 20' POLE-4 CAT 5 2 2 2 2 2 RTS CABINET CABINETS ARE APPROXIMATIONS & SUBJECT TO ~9-~na• RELOCATION TO AVOID CONFLICT WITH EXISTING 10 » 19 POLE-6 CAT 5 1 1 1 1 Rl$ CABINET TRAFFIC SIGNAL EQUIPMENT, UNDERGROUND 1 i POLE-1 /16 1 POLE 2 FLASH UNIT STI UTILITIES, & ADA RAMPS. FOUR FEET MINIMUM OF t 1116 - POLE 5 FLASH UNIT CLEAR SIDEWALK AREA REQUIRED AT ALL LOCATIONS. 2 i ~-4 n6 STF - RTS CABINET O= TRAFFIC SIGNAL RED PHASE 4 2 2 2 2 - a~ 2 LOCATE ALL UNDERGROUND UTILITIES PRIOR TO LOOP 12 8 RTS CABINET LOOPS ALL SETS CONSTRUCTION. CONTACT DIGALERT AT 1-(800) 422-4133 THREE (3) WORKING DAYS PRIOR TO 4 RTS CABINET LOOP LEAD IN DLC 10 10 6 - - CONSTRUCTION. ~s~•` z s h 2 2 2 RTS CABINET POWER PEDESTAL (120V) I8 2 l 3 ALL EQUIPMENT MUST BE LOCATED WITHIN R.O.W. CABINET FOUNDATION DETAIL POWER CIRCUIT 1 RTS CABINET 010 1 1 1 1 1 POLE-1 4 SIDEWALK PANELS REPLACED MUST BE A MINIMUM POLE-2 OF 5'X5'. TRENCHING THRU S/W IS NOT ALLOWED. POWER CIRCUIT 2 RTS CABINET /10 1 1 1 1 -2 D ' POLE-3 CONDUIT SHALL BE BORED BETWEEN OPENED POWER CIRCUIT 3 RTS CABINET 010 1 1 PANELS OR ENTIRE SIDEWALK REPLACED. POWER CIRCUIT 4 RTS CABINET /10 1 1 1 1 1 POLE-4 ' 10 1t 16 POWER: CIRCUIT 5 R1S CABINET MO 1 1 t 1 POLE-5 CONSTRUCTION NOTES Ffl INSTALL REDFLEX CONTROL CABINET AND r --moo A D O 1119 - POWER CIRCUIT 6 RTS CABINET /10 1 1 1 1 POLE-6 FOUNDATION. EXACT LOCATION TO BE DETERMINED _ r R l~ L 5 BY REDFLEX AND CITY. INSTALL h8' GROUND F F E. NEUTRAL POWER /10 6 4 2 2 1 1 1 1 1 2 2 1 FOLLOW POWER WIRES o-- ROD AND BOND TO CABINET WITH #8 BARE Cu. 14, i SOLID BARE BOND /B 1 1 1 1 1 1 1 1 1 1 1 1 i i CONTRACTOR SHALL TERMINATE ALL POWER 33 23 13 7 6 4 4 4 4 11 7 8 4 4 4 12 \ t TOTAL NEW CONDUCTORS ' CIRCUITS INTO RTS CABINET. .f~ ,~=•l 2-3 3- 2- 2' 2' 2- 20 20 20 2' 2- 2- 3- 3' 2-3 2' 20 CONDUIT SIZE INSTALL SPADE LUG & TERMINATE TO SIGNAL HEAD i~ FOR RED PHASE & NEUTRAL. INSTALL INLINE FUSE '1~ 1' NEW/EXISTING CONDUIT N N N N N N E N N N N N E E E N N HOLDER ON RED PHASE CONDUCTOR WITH 5 AMP FUSE INSIDE REDFLEX CABINET. AA ~ VIOLATION LINE INSTALL 40 AMP BREAKER INTO EXISTING CITY MEYER PEDESTAL FOR 120V SUPPLY TO RTS CABINET TERMINATE #14 RED PHASE AND NEUTRAL INTO ~~-S I0 TRAFFIC SIGNAL BLOCK GIVING REDFLEX RED PHASE lilt LLJ FOR N.B COFFEE ROAD. Nit r I+ LL 7 ©INSTALL SOLID STATE RELAYS INTO CITY CABINET 1 ice. TO PROTECT CITY RED PHASE. L' POLE DATA < J EW OR F7 INSTALL NO. 5 PULL BOX. ~~~I NO. TYPE HEIGHT NFyjqTING \ \ \ \ 1 PELCO 10' NEW O F -1 8 INSTALL TEN NEW 3'x8' ENFORCEMENT LOOPS PER - = \G \ 7 CONFIGURATION DETAIL. EACH LOOP MUST HAVE A 2 PELCO 10, NEW m SEPARATE HOME RUN AND LOOP LEAD-IN CABLE. V \ 3 PELCO 10 NEW 9 Of \ \ 4 PELCO 10' NEW U F9 1 N/A 10 INSTALL POLED, 75' NORTH OF VIOLATION LINE, 5 Paco 10' NEW \ i \ g PELCO 10' NEW 1 l;' 11'I- \ 30" FROM FACE OF CURB AND POLE 60 ~o, 40 \ NORTH OF VIOLATION LINE ON MEDIAN. EXACT 40 LOCATION TO BE DETERMINED BY REDFLEX AND 40 ht/Y 0-D.) RED LIGHT LOOP CONFIGURATION CITY. 2G \ * This stamp reflects the modification work 11 INSTALL CAMERA ENCLOSURE, SCENE FLASH UNIT Z ALIAIMM OR i AND ARM, ON POLE 1O AND POLE O. FRANME aASE cA(C M \ \G BUCAG PAS GASKET as outlined. It is not reflective of the ! 12 INSTALL PLATE FLASH UNIT ON POLE Q, 35' s• (IF AUAtlNIIY BASE) existing conditions of the depicted NORTH OF VIOLATION LINE AND POLE 5 , 25'+o 17 intersection or the past design thereof. NORTH OF VIOLATION LINE ON MEDIAN. • ESSI REV.T DESCRIPTION CK'D APP DATE 13 INSTALL POLE O3 , 55' SOUTH OF VIOLATION LINE S., PUBLIC WORKS DEPARTMENT ENGINEERING DIVISION 30" FROM FACE OF CURB AND POLE N 5' SOUTH 36'IAIN OF MEDIAN BULL NOSE ON THE MEDIA EXACT UNcTM As LOCATION TO BE DETERMINED BY REDFLEX AND REQUM BY MA NIF•ACiURER i , No. E013216 CITY OF BAKERSFIELD ~ CITY. 15XWx4• ~.y~i5._ ocn i 1r-WT P-NIFnprFMFNT ® INSTALL CAMERA ENCLOSURE, FAG FLAz)H UNIT, AND ARM ON POLE Q3 AND POLE IA%WCOFFEE 8c TR U XTU N 15 TERMINATE TO POWER CIRCUIT #1 (HOT AND NEUTRAL) ';/\,>/i,/i,!i,/i, © TERMINATE TO POWER CIRCUIT #2 (HOT AND NEUTRAL) f--24VIN--~ 1' W ANCHOR 90LTS (4)x36. REDFLEX TRAFFIC SYSTEMS DW.BY: JB DES. BY. EM ab•ev. RSW ` (ATM)-~ OR A-307 17 TERMINATE TO POWER CIRCUIT #3 (HOT AND NEUTRAL) TOP 4' OF CONCRETE QU SHALL BE r 12-3/4' BOLT CIRCLE 15020 N. 74TH STREET UTY TRAFFIC DOW "w SQUARE. N RFNAYINIG SRE F 1 g TERMINATE TO POWER CIRCUIT #4 (HOT AND NEUTRAL) DEPMAY TH ROUND 2+'MIN .•:c . SCOTTSDALE, ARIZONA 85260 19 TERMINATE TO POWER CIRCUIT #5 (HOT AND NEUTRAL) ' PH: 480 607-0705 FAX: 480 607-0752 Dam- FwC•E WAD °A 1071 010-1 v2 sKG MAW PmcT ® TERMINATE TO POWER CIRCUIT #6 (HOT AND NEUTRAL) RED-LIGHT CAMERA ENFORCEMENT »-4-02 sr 4 of ca 00-D-76 21 NEW CONDUIT MUST BE BORED UNDER ROADWAY. POLE DETAIL .-~-391 k