Loading...
HomeMy WebLinkAboutT7K002SIGNAL_BRIMHALLATHARVESTCREEK_PG1 a ~ O D ~ ~ D LIST OF DRAWINGS SHEET 1 TITLE SHEET SHEET 2 TRAFFIC SIGNAL - BRIMHALL RD AT HARVEST CREEK TRAFFIC SIGNAL AND L/GH _IGHTING SYSTEM SACRAMENTO ~V INSTALLATION ON N ON SAN FRANCISCO CALTRANS 1992 BRIMHA L L ROAD A T HA R VES NEST CREEK ROAD FRESNO w STANDARD PLANS ES-1A ES-3E ES-6B ES-13 A20C T LOS ANGELES ES-1 B ES-48 ES-6R ES-5D A20D Q SAN DIEGO O ES-2C ES-5A ES-6RA T-11 A24A ES-2E ES-5B ES-6S T-12 A24B ~n STATE OF CALIFORNIA J ES-3A ES-5C ES-6T T-13 A24C III\ ~JII QQ ES-3B ES-5E ES-8 T-14 A24D - I rli ES-3C ES-6A ES-10 A20A A24E m II ES-3D ES-6AA ES-11 A20B Q J NO TE: CITY STANDARDS THE CONTRACTOR MUST POSSESS THE FOLLOWING T-19 VALID LICENSES: NNW Y I' CLAS'S' A OR C- >O V CONVENTIONAL SYMBOLS A T THE TIME THIS CON TRA C T IS A WARDED. - - - - - - SECTION LINE _ EXIST. CURB & GUTTER BR/MHALL RLT- i - - RIGH T- OF- WA Y EXIST. A.C. FL.OWLINE RVEST CREEK RD I NO TE: - - CENTERLINE EXIST. EDGE OF PAVEMENT ALL UTILITY LOCATIONS SHOWN ARE APPROXIMATE RAILROAD TRACKS - - GUARD RAIL I AND ARE SHOWN FOR INFORMATION ONLY. THE _X........___.x._._--- FENCE IMPROVEMENTS CONTRACTOR SHALL CONTACT THE USA LOCATOR SERVICE AT 1-800-842-2444, AND VERIFY UTILITY LOCATIONS 48 HOURS BEFORE STARTING CONSTRUCTION. UTILITY SYMBOLS w WATER LINE s SEWER LINE r Z GAS LINE o OIL LINE T BURIED TELEPHONE AERIAL UTILITY CABLE APPROVED BY: W _ OI NEW SIGN X STREET SIGN M.H. MANHOLE F.H. FIRE HYDRANT 11009WE loamy PUBLIC IRECTOR 7 ~ P.P. W.M. r r r l l ` APPROVAL RECOMMENDED: rrrll f POWER POLE El WATER METER Okof ESSIO,NI A ti~~~ oooRE 0, k,R/ ~yc EXISTING MONUMENT W.V. 6Z) WA TER VALVE y ~~4 cti~ ENGINEERING SERVICES MANAGER  C 33710 ® FUTURE MONUMENT G.M. GAS METER * Exp.6-30-98 3-5-9 ul , ~T9TF Civil ~a\P DESIGN ENGINEER \ S. L. STREET LIGHT G. v. GAS VALVE LOCATION M. TION MAP OF CAOF p 0 NOT TO SCALE T TO SCALE TRAFFIC ENGINEER C.O. CLEAN OUT BENCHMARK File Name: 1399R-T.DWG Job No. T7K002 PRE-EMPTION A U TOSCOPE CAMERA TRAFFIC SIGNAL AND NO 1 OP TICAL UNI T LIGHTING SYSTEM INSTALLATION OF BRIMHALL AT HARVEST CREEK 2 SHEETS I' POLE SCHEDULE SIGNALS SIGNS REMARKS LOC. TANDARDuGHnmN VEHICLE WALX W-Dw PPB BPB sT. NAME slcN 51GNAL~ DON'T WALK • ♦ 0 NOTES O 17-3-80 SV-2-T BRIMHALL ROAD INSTALL R73-3 PRE-EMPT m Type C loops shall be 6'x50' except as noted otherwise. Diamond loops shall be 6'x6'. 20 MAS 722 PRE-EMPT 711/721 PRE-EMPT m Detector loops and lead-ins within 8 feet of the curb flowline shall be a minimum of 1.5 inches below the surface of the paving. 15 HARVEST CREEK PROVIDE PIPE TENON ON SIGNAL ARM FOR SV-1-T FUTURE LT-MAT. TB-1 O 26-4-80 40 MAS SP-1-T 02 ROAD INSTALL R34 TB-1 TB-1 ® All loops shall be located in the field by the Engineer. 1 Q Type 170 Controller, and 332 Cabinet assembly shall be supplied by the City. © 1A TV-i-T 02 1 1 (+26VDC OUT) ORG 2 02,05-01,06 (+26VDC OUT) ORG 2 02,05-01,0 2 02,05-01,06 All other equipment and materials shall be furnished by the contractor. 3 04,07-03,08 ® Install City furnished Type 170 Controller and 332 Cabinet assembly. Service shall be 120v/240v Type III-BF, furnished & installed by Contractor. Install 2.0 inch empty conduit and pull box for future interconnect. O PPB ~2 (+26VDC OUT) ORG 3 04,07-03,08 (+26VDC OUT) ORG 3 04,07-03,0 4 02,05 ® Pull box in front of controller shall be #6. Pull box adjacent to P.G.& E. power point shall be P.G.&E. #043459. (CH A DET) YEL 4 02,05 (CH A DET) YEL 4 02,05 5 01,06 Contractor shall install conduit from power point to pull box. All others shall be #5 unless otherwise noted. (CH B DET) YEL 5 01,06 (CH B DET) BLU 5 01,06 O tq TV-2-T SP-1-T 02 (DC COMM OUT) BLU/BARE 6 02,05-01,06 (DC COMM OUT) BARE 6 02,05-01,0 6 02,05-01,06 m Luminaires shall be cutoff type, 200 W. HPSV. 7 04,07 ® All new signal indications shall be 12 inch. SV-2-T HARVEST CREEK (CH A DET) YEL 7 04,07 (CH A DET) YEL 7 04,07 8 03,08 9❑ Street name signs and hangers are furnished and installed by City. 15 O 19-4-80 25 LTM- ASMAT ROAD INSTALL R73-3 (CH B DET) YEL 8 03,08 (CH B DET) BLU $ 03,08 2 9 04,07-03,08 ® AII pedestrian indications shall be new, international symbol type as detailed in the specifications. (DC COMM OUT) BLU/BARE 9 04,07-03,08 (DC COMM OUT) BARE 04,07-03,9 11 All unused, salvaged material shall be delivered, by the contractor, to Wastewater Plant #2 at Mt. Vernon Ave. south of Fwy. 58. Contact Larry Aldano at least 24 hours prior to delivery at (805) 326-3152. ® Location of the standards shall be 5' behind the flow line or as directed by the Engineer at the site. NOTE: "Lone closure for placing the detector loops are only allowed between 8:30 and 3:30 PM. ASSUMING TB9-2 & TB9-3 ARE UNUSED ON THE J FILE, MOVE WIRES ON J11-J & JI l -K ® All utility locations shown are approximate only and represent the best information supplied by the various (TWISTED PAIR) TO J12-E & J13-E utility companies. Final responsibilty for locating utilities in the field is the Contractors. RESPECTIVELY. © Contractor shall remove striping and pavement markings as indicated on the plan. ® Remove and salvage existing street light and standard on the southeast corner. Coordinate with the installation of new i luminaires. Remove and dispose of street light foundation. Disconnect and abandon service conduit per CalTrans State OPTICOM FIELD WIRE DETAIL Standard Specifications Dated July 1992, Section 86-7. Maintain existing street light circuit. © Install City-furnished Opticom 711 and 722 pre-emption devices where indicated. The Contractor shall furnish and install cables NTS and mounting hardware. The Opticom 762 phase selector unit will be pre-installed in the cabinet by the City. Contractor shall make internal connections within cabinet for a fully operational pre-emption system, refer to wiring detail. Exact hardware mounting placement shall be determined by the Traffic Engineer in the field. W 0 O °I ul b z EX. EDGE OF PAVEMENT - w ----w - w R/W M.H. M.H R~ - - - - - - - s_---- - 300' - - - - - - - . _ G-------------- G - ---..f3 . 06 - I ---t~6 5 06 5 DETAIL 380 4 TYPE IV(L) 1 N DETAIL 29 3 1 06 S89'10'35.7"E (0 - - - - - _ - - - - _ - - - - - 01 i 1 7z - - - sl 150' 50' w v~) - _ - - = r Z) 25' - ~ 5 2 2 bTYPE IV(L) 3Q DETAIL 22 3QDETAIL 22 5 . s.---------------_--.-.._..----------•--_._._.._....-----._._ - - EX. CURB, GUTTER & SIDEWALK _ . . G _ _ L- 711 -nE - (D TYPE IV(L) - - - - - - - - - - - - - - - - - - - - - - - - - - P A TT/ _ T..ti - E f - - - ATS' _ . . _ _ (2R I ~ 5 - - - - - EX. BLOCK WALL R/W - - - - E. M. EX. BLOCK WALL I F.'H. 4 300' I I 4 II I G ©R26 it 6 'R26 II I 6 iR26 STRIPING/MARKING NOTES I I I 417L I I 4 (TYPE IV(F 4 ITYPE IV(R) 0Remove stripe. All existing striping in future I I ~ II ~ I II a d crosswalk area or limit line area to be removed. d ©R26 I I 8 I I 8 2DRemove and salvage sign and post. I ❑ I I I II N 3QApply thermoplastic stripe and install pavement marker per I I o f ~7U I I referenced detail from CalTrans Standard Plans, Dated 1992. I II ~ (a)Apply thermoplastic pavement marking as indicated. I I I ^r I I I I Q5 Apply thermoplastic crosswalk, or limit line (12" white) I I a I I I © Install sign and post as indicated. I 'I I I Q I I I I I I I ©R26 II II I I EX. PG&E PULL BOX NOTES: i i I I I I 1. CONDUIT® IS FOR FUTURE INTERCONNECT INSTALL PULL WIRE ONLY. I I I I 11 I 2. CONDUITS DESIGNATED (N)EW OR (E)XIST REFER TO CONDUITS ONLY, ALL CONDUCTORS SHALL BE lV I I II II NEW EXCEPT WHERE NOTED AS (EX.) l II II II I I I I (DI TYPE IVI 4 i TYPE IV(L) - - - - E 01 , \ \ QROfESSlpyq~ I ~ ~ ~F0 pRf ~ • K, c^ II t2~ I I CONDUCTOR SCHEDULE Q I~ III " 2" 2" 2»» O I I 3' I I 2-313.51 3" 3» 3" 2" 1.5" 2 1,5.b 1.5 " 2 2" 3" 2" 3" 2 It 9-7 I I ~ REGISTERED CIVIL ENGINEER o C 33710 > CONDUCTOR RUN 01 2L ~ ® ® ® ® ® ® ® ® ® II II l ~ ~ 1 ^ ^Y ~ , /1-~ 1~ * (1 Exp. 6-30-98 yt NEW OR EXIST. N N N N N N N N N N N N N N N N N N N - - - , , \ n n . " O jl I Ii I I I I 28 CUNUUCIUK J Z [ 9 CONDUCTOR 1 1 1 1 I II II Y❑E.M. \ \ u i i yr DMr\C-',,>rJLLV 9T pFl CAFE 1399R-T_ DWG 1501 TRUXTUN AVE. F 5 CONDUCTOR 1 1 1 1 I II U N II BAKERSFIELD, CA 93301 I I _ PN T71<002 3 CONDUCTOR 1 1 1 II `x° a s II 1 1 I II x ~ II I ` ,11 ogre O, - "00 PRE-EMPTION CABLE 2 1 1 1 i 1 I I r o I I ° Traffic Signal and UgNmg DRAM 11/20/96 10 LIGHTING 2 2 2 2 2 2 2 4 I I I mO I I II I J EX. BLOCK I y,.~.•wbdo / w R.L.T. 0 1 DET. 1 1 1 1 1 SCALE i=20' I I I I of WALL Insta on 0 2 DIET, 2 2 2 1 \ I I I I I J1ESIa1 ENaNEER 0 3 DIET. I I &*Mall Rd at Harvest Creek Rd R.L.T. I II I II III I 0 4 DET. 2 2 2 1 PROJECT ENQNEER DLC 0 5 DET. I I I I I I I I 0 6 DET. 2 2 2 2 2 1 I I I a I I Traffic Installatron wx =wRIGHT 0 7 DET. I I a I I 0 8 DET. I I I J Controller Detal S/W Corner CITY OF BAKERSRELD NQ TOTAL 7 5 5 3 3 1 1 2 2 1 I I o w I I 2 3 3 I I,I II II SCALE 1=10 PUBLIC WORKS DEPARTMENT s„2 2 2 II O II A 2 SERVICE PRIMARY 118 ~ (j SERVICE SECONDARY 8' I I 22' 22' 1 1 8111, a INTERCONNECT