Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T8K057SIGNAL_LIGHTING_WHITELNATMOUNTAINVISTA_PG1
. . - ....w .a:. r..-..f y._r. ....w r' Y ~.r- a. u. ,M4°.f"',..Y.yS:)'^rv~Ji'+1'r'".~~L~~';:4.~'ff-ti 4A~Y%,3'!1Xf6 ~°`~'~.~'P~SC _ r i I~ 'IED)AKE][- T',RSFIELD LIST OF DRAWINGS CITY OF l TITLE SHEET DEPARTMENT OF PUBLIC WI UC WORKS 0 2. SIGN AND STRIPING PLAN ON WHITE LANE AT `1 co MOUNTAIN VISTA DRIVE I- 3. TRAFFIC SIGNAL AND LIGHTING SYSTEM PLAN ON PLANS FOR INS TALLATIC WHITE LANE AT MOUNTAIN VISTA DRIVE ,LATIO N OF '"~0 "T° o siw ReAlw= CITY OF BAKERSFIELD z TRAFFIC SIGNAL AND LIGHTING iTING SYSTEM ON Room w 0 o at Mountail White Lane Lain Vista Drive w LOB > 0 CALTRANS 1992 STANDARD PLANS Q ES-1A ES-3E ES-6S T-12 A24B U) ES-11B ES-413 ES-6T Al OA A24C STATE OF CALIFORNIA Z CAMWO MEDIA Q ES-2C ES-5C ES-8 A1 0B A24D ' CAMINO ME z Z) ES-2E ES-6A ES-10 A20A A24E ES-3A ES-6AA ES-11 A20B NOTE: Q 7 cr THE CONTRACTOR MUST POSSESS A ES-313 ES-613 ES-13 A20C "ORTH LAUR IXI 9OULEVARD VALID CLASS A OR C-10 CONTRACTORS Z LICENSE AT THE TIME THIS CONTRACT Q ES-3C ES-6R ES-5D A20D IS AWARDED. J NORTH HALF ►AOON vE ES-3D ES-6RA T-11 A24A White Lane ALL UTILITY LOCATIONS SHOWN ARE Z BAKERSFIELD CITY STANDARDS APPROXIMATE AND ARE SHOWN FOR 0 INFORMATION ONLY. CONTRACTOR m°"'" ""`F M°°" SHALL CALL USA LOCATOR SERVICE AT (800) 642-2444 AND VERIFY UTILITY H S. c SID . ~ - LOCATIONS 48 HOURS BEFORE STARTING U) CONSTRUCTION. P ROJEC ` I c: U r Z OM7RMT BOULEVARD TION CONVENTIONAL SYMBOLS LOCA ::3 - - SECTION LINE T .-r- LEVEE ACHECO ROAD - - - - RIGHT-OF-WAY RAILROAD TRACKS CENTERLINE WALL Z EXISTING TOPO k- - CULVERT -X- FENCE HEDGE FUTURE STRIPING GUARD RAIL PENSINOER ROAD / . I Z UTILITY SYMBOLS U APPROVED BY: ~ 'Y U ! ~ppFESSip, WATER LINE SEWER LINE LA- LL- GAS LINE OIL LINE JOHN - p D. swum Q t1o °1°zb PUB IC WORKS DI TOR DATE BURIED TELEPHONE AERIAL WIRE CABLE Gxp.6-30-w A AERIAL CABLE • LL MANHOLE ARE HYDRANT LOCATION MAP AP ISTERED CIVIL ENGINEER DATE OF, C110 ;AP;PROVAL RECOMMENDED: 0 0 F POWER POLE WATER METER NOT TO SCALE SERMCES MANAGER F- Q EXISTING MONUMENT wAiuc ♦ALvc J J FUTURE MONUMENT GAS METER TRAF1-'G EN(AA F- EXISTING STREET LIGHT GAS VALVE W Z EXISTING SIGN NEW SIGN 6~ r. - lti - cr Ell O RUNTGERS&SCHULERC1WLENGINEERS PLANS FOR INSTALLATION OF SIGNAL AND NO 180121st STREET, SUITE 4 OF Z AAARSFnW,CA93901 LIGHTING SYSTEM ON 3 Q (80)W-1969 PAX(803)n7-19913 WHITE LANE AT MOUNTAIN VISTA DRIVE SHEETS [ m I r ~ p. II I I I It II 11 if II I I II II II II I II I I II I II I I I II I II I NOTES II I I II 1 II I II I II I 01 Remove and salvage existing Stop Sign. II I 1 II 1 II I Q2 Remove and salvage existing Stop Ahead sign. 11 I I n I II I I II II I I II I I II 03 Obliterate existing pavement marking. I II 1 II II I II I I II I II I ® Obliterate existing stripe. II I 1 II I II I Q5 Remove existing Stop Ahead sign panel and replace with W41 sign panel. tl t I II 1 II I I II I I II I II I PAVEMENT MARKING QUANTITIES 11 I I II II II II 11 TYPE L) I II I II I TYPE LINEAR FEET II III It I 11 I I t ARRO(W I I I I I II I II ) I I II I 4" WHITE THERMOPLASTIC 400 LF II I II II STRIPE (SOLID) II I I I I I II II I ~ I 1 ~ II I II II 4" WHITE THERMOPLASTIC 11 1 I II II I I I I I I II 1 STRIPE (DETIAL 9) 350 LF II I I I° 1 1 I I I II 1 I I I II I 4" DOUBLE YELLOW THERMOPLASTIC NOTE: ALL WORD PAVEMENT MARKINGS ARE 111 -7 II I 1 ? 1 I II I 300 LF II I STRIPE (DETAIL 22) TO BE OBLITERATED AS A BLOCK, NOT II I 1 $ II I AS INDIVIDUAL LETTERS. II 1 1 II 11 II I II II 8" WHITE THERMOPLASTIC 220 lF 1 It M2 a$ II 1 I II II II II II I STRIPE (DETAAL 38) 1 it I ~I ~i I I I I I II I 4" WHITE THERMOPLASTIC II 14'' I I II I II I 230 LF II 93 I I II I II I STRIPE (DETIAL 40) t t 1 1 I I I II ~ 1 1 II I II I II o I 1 ~ II 11 I I II II TYPE IV ARROW 150 SF _ ( k" I I I It i I II II I ARROWE(R) 1114 7 I I ~ It ° I I ° I TYPE VI ARROW 168 SF 11 I I II TYPE VI II TYPE VI ARROW (TYP) I I ~ o II I 'Q' 1cc41 I+I l\ \ jig A 0%, 1, " \ A\ \ < \ v~ \ \ i-- - - - RW - - - _ .12 --Lw - ---~a/ 4c - - - - - - - - - - - - - - - - - - - DETAIL 40 FUTURE STRIPING BY OTHERS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ - - - - - _ - - - - - - - - - - - - - - - - - - - - - - - - - - - T ' 24 + 0D 25 + 00 ^ . ` 26 ♦'00 - - - - - - - - - - - - - + 00 - - - - - - - - - - - - - - - ~ As 00~ 29 + 00 ' _ r r r 00 30 + 00 31 + 00 34 + 00 - - - - - - - - - - - - - - - - - - - - - - - TYP£ IV ARROW (l) (TYP) Imo- - . - - - - FUTURE STRIPING BY OTHERS DETAIL 40 11L 40 I, f FUTURE MEDIAN do ROADWAY - - - ---I i.w - 71- - _ _ _ _ _ _ 14 X12 8 4 1 4% I v^~\ cli J i / N Ir ~ J \ II N N II II I II 11 1 II 1 1 11 DETAIL 22 II I II ° I II I II 90'x10' TAPERII II I I II 2' II II I II II I I I II I II TYPE VI ARROW (TYP) t I I 1 I III II I 1 I II II I k14 I I II < g I II w 14'11 I I II II I I II II 44 II I II II I II ~ II I II I II N ~f I I II I o I,~ II 11 I I II II I II N J II II I MATCH LINE I II Z 11 II I I II II I I I II < II u II I I II O1 ui II II I I II 'op' II I I II o 1 I 11 o II TYPE I\ II I I I 11 I (TYP) I TYPE IV ARROW (R) I II 11 I I (TYP) I I I 11 I I 11 $ ~ 'I 1 © 11 1 I II II I II I II I II II I I II ( j II II I I II 11 I 11 I I I I MATCH EXISTINQ I I I I TYPE IV I I II I II STRIPING 11 I II I I I ARROW (L) ~ I II )v\ (TYP) 11 I 11 I I 11 I `"i : I it I II I II I II II ~ppFESSj I II DETAIL 22 II I 1 `Y+ i J I 90'x10' TAPER I I PER II y I Ii II I I u' J" a SMAL t ik No. men * Ev.6-70-N RR GIs~VIL ENGINEER DATE CF CAE SIGN AND STRIPING PLAN ON a`E"'° 2 ®1C' ~t'1~11~~1~11~ey RIISI711GB/R&SCIULM aMMVGWF" MM J.D.S. ~ J.D.S. 3-19-98 SCAU 1" = 30' WHITE LANE AT MOUNTAIN VISTA DRIVE OF 3 DAtAR , s i'~n I.J.P. ~m R.F.R. praim 1" = 30' DEPARThEM OF PUBLIC WIORRS 108-11.1 REV. DESCRIPTION DATE BY REV. DESCRIPTION DATE BY fI I NOTES POLE SCHEDULE 1 Type 170 Controller, and 332 Cabinet assembly shall be supplied by the City. All other equipment, unless stated otherwise, PHASE DIAGRAM LOC. STANDARD P"'m SI WALX W-DW PPS SIGNS REMARKS shall be furnished by the contractor. VEHICLE POWT M • r ST. NAIL SIGN ® Instoll City furnished Type 170 Controller and 332 Cabinet assembly. Service shall be 120v/240v Type III-81=, furnished & installed 0407 by Contractor. Mount controller cabinet on foundation per Caltrons STD ES-48 with foundation height increased from 3 1/2" to 12" 1' I I I I I reP ~ OA 26-3-80 15 MSV- AS1-T SP-1-T 08 06 WHITE LANE UPI F = 16'* -ew L II I ~ 06 04P 45 LT-MAT AUTOSCOPE 12mm 3 Pull box in front of controller shall be No. 6. Pull box adjacent to P.G.& E. power point shall be P.G.&E. #043459. Interconnect pull I I i ~ I I I I I 1 boxes shall be No. 5 w/ extension. All others shall be No. 5. 11 Q 1 I I I ~I I I II 01 06P 07 ~l I I I -.4-06 © to Tv-2_T SP-1-T 06 08 4 Luminaires sholl be cutoff type, 200 W HPSV at locations A and E, and 300 W HPSV at locations C and G l I 1 i I i i II II Ii 05 01 01 and 06 02 - N 04 and 07 5 All new signal indications sholl be 12 inch. I I I V) I I I1 1 I I I r 03 © 2SA-5-80 15 AMIAS MOUNTAIN 1213 F - 22'• 6 Street name signs and hangers are furnished and installed by City. i I j 1 1 s SP-1-T 02 08 I I I o2 - w 02 and 06 55 _ VISTA DRIVE AUTOSCOPE 8 mm LTUAT 7 All pedestrian indications shall be new, international symbol type as detailed in the specifications. I1 I LLJ I I I I I 1 8 Salvaged luminaires sholl be delivered, by the contractor, to a location to be determined. Contact I 1 Z ~ i 1 i i II I I I ~ P 03 and 07 II 08 11 it 02 and 05 030308 08 O IA TV-2-T SP-1-T 08 02 Larry Aldano of 326-3781 for location. Salvaged sign panels shall be delivered to the City Corporation Yard. I i Q ~ II i I 1 1 II I I I 04 15 SV-I-T 4 1213 F - 14'* 9 Location of the standards shall be located at back of sidewalk, as shown on plans, or as directed by the Engineer at the site. I1 I- Q I I II i1 I 1 I I ~oap O 24-3-80 35 MT-MAT ~-1-T 04 02 WHITE LANE AUTOSCOPE 12 mm 10 Lone closures are only allowed between 8:30 - 4:30 PM. I I I Z i I I I 1 II 10 Remove and salvage existing street light and standard. Removal to be coordinated with the installation of new luminaires. i i O 1 i I 1 II~ O 1A TV-2-T SP-1-T 02 04 Disconnect and abandon service conduit per CalTrans State Standard Specification Dated July 1992, Section 86-7. I I I I I I 1 II I Abandon street light foundations per Section 86-2.03 of the Standard Specifications. Maintain existing street light circuit. 11 I I I I II II I 08 04 and 08 I I II © 75- 29A-5-80 MAS SP-1-T 6 04 ® Install City furnished Opticom four 711 pre-emption devices. The Contractor shall furnish and install all cables and I I I I 1 I 1 ~I I I I MOUNTAIN Fl2Tl 31 - 22 55 MAS - VISTA DRIVE AUTOSCOPE 8 mm mounting hardware, The Opticom 762 phase selector unit will be pre-installed in the cabinet by the City. Contractor I I 1 I I I I 1 II I shall make internal connections at cabinet for a fully operational pre-emption system. Exact pre-empt hardware I1 1 1 I I 1 II I O 1A TV-2-T SP-1-T 04 06 mounting placement shall be determined by the Traffic Engineer in the field. i i 4 ~II I I I 1 II I ®Attoch two 12 mm and two 8 mm City furnished Autoscope camera to luminaire most arm. All wiring shall be installed O I 1 I I _ __y 1 • F DISTANCE ON CALTRANS STANDARD PLAN internal to Poles. Locate 3' from the center of luminaire. The video and power cable openings shall be 4' from - T I I the center of the luminaire. 1 04 11 1 1 111, I I I. 3 I I ` \ 3 I 1 08 B o ~ RW RW Ci , 06P - / / 1 / 06 I x ' I 26 + '00 27 + 00 - - - - - - - z 100, 29 + 00 - - - I - 01 ' 29 + 00 I, 30 + 00 T y 1 + 0 } _ - t1 ' 1 ~ 02 WHITE LANE FUTURE MEDIAN / 1 02 i 1 02P - - - _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - '02P ~ / - _ _ _ _ _ _ _ _ _ _ _ _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ' - - - - - \ / I - of8pp 44, POIN SERVICE C ~x\0~ 04 07 - POINT ~ ~ --I CONTROLLER AREA DETAIL D NTS 9 I1 II 08 711 PRE-EMPT E ii 04 I 1 111 I I I I I I TB-1 I 11 II l l II 11 1 I I 11 11 ~ II I / I (+26VDC OUT) ORG 02,05-01,06 I I I I I II ~ I I I II II I I i I I II , ~ II ~ C 0 N D U C TO R SCHEDULE +•I Beldens828 ting Conduit (+26VDG DUT> 0RG3 ~4,o7_s3,o8 r r w w w w w w w • r w (CH A DET) YEL 4 02,05 I I I I I -3 3" 3" 3"• 3" 3 4 3+ 3 3+ 3 2 3• 2 2r 2 2 2 2• 3r• 04P CONDUCTOR RU 1J © ® ® ® B DET) YEL 5 01,06 1 I I I I I I I I ,~i (DC COMM OUT) BLU/BARE 6 02,05-01,06 I I I I I I NOTES A B B C C C C C I I I I I 28 CONDUCTOR 4 1 1 1 1 3 2 2 1 1 (CH A DET) EL 7 04,07 I I I I I I II ~ ~ 9 CONDUCTOR 1 1 1 1 1 (CH B DET) YEL 8 03,08 I I I I I I V'±." 5 CONDUCTOR 1 1 1 1 1 (DC COMM OUT) BLU/BARE 9 04,07-03,08 I 1 I I I I II I <1\ , 10 LIGHTING 2 2 2 2 2 2 2 2 2 4 I I I I I I I ~•L`: ,.,.......nom n....~n m n z z z z z Z 2 C n n r, • i r, r, n , n n r n r r. I I t 1 1 AVM rr- rv~ R is Ut' 11GUM I-ILLU VVIKL UL I AIL I I I I I I AUTOSCOPE CABLE 4 1 1 1 1 3 2 2 1 1 I I PpOfESS/p~,. / 2 SERVICE 2 3 3 NTS I I I I 12 PAIR X119 AWG INT) I 11 I I NOTES A. RECORD PLANS SHOW CONDUIT AT LOCATIONS SHOWN. CONTRACTOR TO CONFIRM NOTE: ASSUMING T89-2 & 789-3 ARE UNUSED ON 1.. 1 I I I I I I v J" D. wHuu LOCATION AND EXISTENCE. IF NOT ABLE TO LOCATE CONTRACTOR SHALL INSTALL NEW CONDUIT. THE J FILE, MOVE WIRES ON J11-J J11-K i i r I I I ft. 51an * EV. Fao-a * o V P B. CONTRACTOR TO INSTALL PULL BOXES, AS NEEDED, AT ENDS OF CONDUIT PLACED BY OTHERS (TWISTED PAIR) TO J1?-E do J13-E RESPEC7)VELY. PRIOR TO PROJECT 7- s7x-- le C. INSTALL PULL ROPE FOR FUTURE INTERCONNECT CONDUCTOR GIS RED CIVIL ENGINEER DATE qr CAL%F (f¶ ~ RUE77G RS&SCHUL RCNILPIVMEMS M J.D.S. J.D.S. 3-24-98 ICAE , cHecm CJl 11 OF BA=R 1891 LitSMW, A=4 Sim q,ojwr 1 = 20 F TRAFFIC SIGNAL AND LIGHTING = 20• SYSTEM PLAN ON 3 DW~ P~7BLZC w$ I.J.P. ,N R.F.R. 108-11.l L.REV DESCRIPTION DATE BY REV. DESCRIPTION DATE BY WHITE LANE AT MOUNTAIN VISTA DRIVE OF 3