Loading...
HomeMy WebLinkAbout2011 FMC RESULTS (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.waterboards.ca.gov) Monitoring System Certification For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility: Pacific Bell Telephone Co. dba AT&T Califomia GEO PAR#SA004 Address: 1918"M" STREET City: BAKERSFIELD Zi : 93301 Facility Contact Person: Grant Armstrong Contact Phone No: 661-327-6903 Make/Model of Monitoring System: Veeder Root TLS-350 Service Date: 01/13/2011 B. Inventory of Equipment Tested/Certified IIIIIIIIIIIIIIIIIIII Check the appropriate boxes to indicate specific equipment Inspected/serviced: 25 IE Tank ID: SA0040001 Tank ID: ®In-Tank Gauging Probe Model:847390-109 ❑In-Tank Gauging Probe Model: ®Annular Space or Vault Sensor Model:794390-420 ❑Annular Space or Vault Sensor Model: ®Piping Sump/Trench Sensor(s) Model:794380-208 ❑Piping Sump/Trench Sensor(s) Model: ®Fill Sump Sensor(s) Model:794380-208 ❑Fill Sump Sensor(s) Model: ❑Mechanical Line Leak Detector Model: ❑Mechanical Line Leak Detector Model: ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: ®Tank Overfill/High Level Sensor Model:790091-001 ❑Tank Overfill/High Level Sensor Model: ®Other(Specify equipment type and model in Section E on Page 2) ❑Other(Specify equipment type and model in Section E on Page 2) Tank ID: Tank ID: ❑In-Tank Gauging Probe Model: ❑In-Tank Gauging Probe Model: ❑Annular Space or Vault Sensor Model: ❑Annular Space or Vault Sensor Model: ❑Piping Sump/Trench Sensor(s) Model: ❑Piping Sump/Trench Sensor(s) Model: ❑Fill Sump Sensor(s) Model: ❑Fill Sump Sensor(s) Model: ❑Mechanical Line Leak Detector Model: ❑Mechanical Line Leak Detector Model: ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: ❑Tank Overfill/High Level Sensor Model: ❑Tank Overfill/High Level Sensor Model: ❑Other(Specify equipment type and model in Section E on Page 2) 1 ❑Other(Specify equipment type and model in Section E on Page 2) Dispenser ID: Dispenser ID: ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: ❑Shear Valve(s) ❑Shear Valve(s) ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) Dispenser ID: Dispenser ID: ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: ❑Shear Valve(s) ❑Shear Valve(s) ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) Dispenser ID: Dispenser ID: ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: ❑Shear Valve(s) ❑Shear Valve(s) ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to this Certification is information(e.g. manufacturers'checklists)necessary to verify that this Information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): ®sy ®Alarm history report Technician Name (Print): Patrick Banbury Si nature: Certification No: A20465 IlLicense No: 88 Testing Company Name: TAIT ENVIRONMENTAL SERVICES I Phone No: 714 560-8222 Testing Company Address: 2131 South Dupont Drive Anaheim CA 92806 JDate of Testing/Servicing: 01/13/2011 Monitoring System Certification Page 1 of 4 IIIIIIII�IIIIIIIIII 26 12/07 IE Monitoring System Certification Address: 1918"M" STREET BAKERSFIELD 93301 Service Date: 01/13/2011 D. Results of Testing/Servicing Software Version Installed: 123.01 Complete the fol owinq checklist: •Yes ❑ No* Is the audible alarm operational? •Yes ❑ No* Is the visual alarm operational? •Yes ❑ No* Were all the sensors visually inspected,functionally tested, and cofirmed operational? •Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? ®Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g. modem) operational? ❑ N/A ❑Yes ® No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes:which sensors initiate positive shut- ❑ Sump/Trench Sensors ❑ Dispenser Containment Sensors ❑ N/A down?: Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ❑ Yes ❑No ❑Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the ® N/A tank fill point(s)and operating properly?If so, at what percent of tank capacity does the alarm trigger?: ❑Yes* ® No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E below. Was liquid found inside any secondary containment systems designed as dry systems? El Yes* ® No If yes,check the type(s)of liquid found and describe causes in Section E, below. ❑ Product ❑Water ®Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports, if applicable ®Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? *In Section E below,describe how and when these deficiencies were or will be corrected. E. Comments Other sensor from page 1: L4 Transition Sump sensor 794380-208-Certified Section D: Back up generator system no possitive shut down or failsafe. An Overfill Prevention Valve is installed in the drop tube. Monitoring System Certification Page 2 of 4 12/07 Monitoring System Certification Address: 1918"M" STREET BAKERSFIELD 93301 Service Date: 01/13/2011 F. In-Tank Gauging/SIR Equipment ®Check this box if tank gauging is used only for inventory control ❑Check this box if no tank gauging or SIR Equipment is installed This,section must be completed if in-tank gauging equipment is used to perform leak detection monitoring Complete the fol owing checklist ❑Yes ❑ No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? ❑Yes ❑ No* Were all tank gauging probes visually inspected for damage and residue buildup? ❑Yes ❑ No* Was accuracy of system product level readings tested? ❑Yes ❑ No* Was accuracy of system water level readings tested? ❑Yes ❑ No* Were all probes reinstalled properly? ❑Yes ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H below, describe how and when these deficiencies were or will be corrected G. Line Leak Detectors (LLD): ®Check this box if LLDs are not installed Complete the fol owing checklist ❑Yes ❑ No* For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? ❑ N/A Simulated Leak Rate(check all that apply) ❑ 3.0 g.p.h ❑0.1 g.p.h ❑0.2 g.p.h ❑Yes ❑ No* Were all LLDs confirmed operational and accurate within regulatory requirements? ❑Yes ❑ No* Was the testing apparatus properly calibrated? ❑Yes ❑ No* For mechanical LLDs, does the LLD restrict product flow if it detects a leak? ❑ N/A ❑Yes ❑ No* For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? ❑ N/A ❑Yes ❑ No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ❑ N/A ❑Yes ❑ No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? ❑ N/A ❑Yes ❑ No* For electronic LLDs, have all accessible wiring connections been visually inspected? ❑ N/A ❑Yes ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H below, describe how and when these deficiencies were or will be corrected H. Comments Line Leak Detector not installed in the backup generator system. Monitoring System Certification Page 3 of 4 12/07 Monitoring System Certification Address: 1918"M" STREET BAKERSFIELD 93301 Service Date: 01/13/2011 UST monitoring Site Plan DAY TANK ROOFTOP GENERATO EXTERNAL R ALARM TRANSITION SUMP 794380-208 ALLEY WAY VENT-''O ANNULAR 794390-420 LU FILL SUMP V) AT&T SA004 PARKING LOT 794380-208 rn 1918 M STREET TLM PROBE M BAKERSFIELD, CA 847390-109 STP SUMP 794380-208 SA0040001 Date map was drawn: 01/13/2011 Instructions If you already have a diagram that shows all required information, you may include it, rather than this page, with your Monitoring System Certification. On your site plan, show the general layout of tanks and piping. Clearly identify locations of the following equipment, if installed: monitoring system control panels; sensors monitoring tank annular spaces, sumps, dispenser pans, spill containers, or other secondary containment areas; mechanical or electronic line leak detectors; and in-tank liquid level probes (if used for leak detection). In the space provided, note the date this Site Plan was inspected. Monitoring System Certification Page 4 of 4 12/07 SWRCB,January 2006 SPILL BUCKET TESTING REPORT FORM This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printout from tests(if applicable),should be provided to thefaacility owner/operator for submittal to the local regulatory agency. 1.FACILITY INFORMATION Facility Name:Pacific Bell Telephone Co.dba AT&T California Date of Testing:01/13/2011 Facility Address: 1918"M"STREET BAKERSFIELD CA 93301 GEO PAR#SA004 Facility Contact:Grant Armstrong Facility Phone: Date Local Agency Was Notified of Testing:01/06/2011 Name of Local Agency Inspector if present during testing): Ernie Medina 2.TESTING CONTRACTOR INFORMATION Company Name:TAIT ENVIRONMENTAL SERVICES Technician Conduct' Test:Patrick Banbury Credentials: ®CSLB Contractor ®ICC Service Tech ❑SWRCB Tank ❑Other(Specify) Tester License Number(s):A ASB HAZB C-10. 588098:5254955-UT 3,SPILL BUCKET TESTING INFORMATION Test Method Used ®Hydrostatic ❑Vacuum ❑Other Test Equipment Used:Tape Measure 1EQuipment Resolution: 1/16" Identity Spill Bucket(By Tank Number, 1 SA0040001 2 3 4 Stored Product,etc) ❑Direct Bury ❑Direct Bury E)Direct Bury El Direct Bury Bucket Installation Type ®Contained in Sump ❑Contained in Sump El Contained in Sump ❑Contained in Sump ❑On top of AST ❑On top of AST ❑On top of AST ❑On top of AST Bucket Diameter inches I V Bucket D th inches 16" Wait Time between applying 5 min vacuum/water and start of test Test Start Time: 9:15am Initial Readin R(Ri): 13.50" Test End Time: 10:15am Final Reading 13.50" Test Duration: 1 Hour Chan a in Reading Rf-Ri : 0.00" Pass/Fail Threshold or Criteria: 0.00" Test Result Pass Comments:Liquid removed and taken back to TES. CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information c.ined In this report is true,accurate and in full compliance with legal requirements Technician's Signature r' Date 01/13/2011 J, DATA CHART FOR USE WITH PETRO TITE LINE TESTER Job Number. ATTPL11 Date of Test: 01/13/2011 LOCATION: 1918 M Street Bakersfield CA 93301 Street No. City State Telephone No. OWNER: Pacific Bell Telephone Co. dba AT&T California Name Address Representative Position Telephone No. OPERATOR: Pacific Bell Telephone Co. dba AT&T California Name Dealer,Mgr.Or Other Address(If different than location)Telephone No. REASON FOR TEST: Annual Compliance TEST REQUESTED BY: Name Position Order No. Billing Address SPECIAL INSTRUCTIONS: CUPA Inspector on site for test ---- -- -------------------------------------------------------------.-.-._.------------------------------------------ I declare under penalty of perjury that I am a licensed tank tester in the State of California and that the information contained in this report is true and correct to the best of my knowledge. i r TECHNICIAN: Patrick Banbury 90-1413 Name Signaturr license Number IS A TANK TEST TO,BE MADE WITH THIS LINE TEST? ❑Yes ® No MAKE AND TYPE OF PUMP OR DISPENSERS Turbine WEATHER Mild TEMPERATURE IN TANKS °F °c COVER OVER LINES Concrete/Black Top APPROX. BURIAL DEPTH 24" PRESSURE VOLUME EACH LINE TIME PSI READING TEST RESULTS AS TESTED MILITARY BEFORE AFTER BEFORE AFTER NET CHANGE CONCLUSIONS Diesel 0940 PRETEST 75 SA0040001 1010 75 60 .0000 G.P.H. 1040 60 60 Line Tight®YES ❑ NO 1055 60 60 .0555 .0555 .0000 Bleed Back®OK 1110 60 60 .05 1 .0555 .0000 ❑ NOT OK 1111 BLEED BACK 60 0 .0555 1 .0990 .0435 BLEED BACK START TEST G.P.H. Line Tight❑YES ❑ NO Bleed Back❑OK ❑ NOT OK BLEED BACK BLEED BACK START TEST G.P.H. Line Tight❑YES ❑ NO Bleed Back❑OK ❑ NOT OK BLEED BACK COMMENTS: Westem Fiberglass 1.5"flex line. I50301 JAN 17, 2011 2:57 PM # 1:BKFDCAI2 SA004 150302 JAN 17, 2011 2:57 PM # 2:1918 M ST. El 150303 JAN 17, 2011 2:57 PM # 3:BAKERSFIELD,CA 93301 I50304 JAN 17, 2011 2:57 PM # 4:661-631-2540 I51700 .JAN 17, 2011 2:57 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM ❑ I50F00 JAN 17, 2011 2:57 PM MON DD YYYY HH:MM:SS xM I10200 JAN 17, 2011 2:57 PM BKFDCA12 SA004 1918 M ST. BAKERSFIELD,CA 93301 661-631-2540 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. . 164399 163979 2 INTERSTITIAL BD 201871 201714 3 UNUSED 15000000 15000000 4 UNUSED 15000000 15000000 5 UNUSED 15000000 15000000 6 UNUSED 15000000 15000000 7 UNUSED 15000000 15000000 8 UNUSED 15000000 15000000 9 COMBO I/O BOARD 9982 9962 10 UNUSED 15000000 15000000 11 UNUSED 15000000 15000000 12 UNUSED 15000000 15000000 13 UNUSED 15000000 15000000 14 UNUSED 15000000 15000000 15 UNUSED 15000000 15000000 16 UNUSED 15000000 15000000 COMM 1 FAXMODEM BOARD 40367 40318 COMM 2 UNUSED 15000000 15000000 COMM 3 UNUSED 15000000 15000000 COMM 4 UNUSED 15000000 15000000 COMM 5 UNUSED 15000000 15000000 COMM 6 UNUSED 15000000 15000000 160100 JAN 17, 2011 2:58 PM TANe CONFItURATION DEVICE LABEL CONFIGURED 1 DIESEL TK#SA004U001 ON 2 OFF 3 OFF 4 OFF ❑ 160200 JAN 17, 2011 2:58 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 DIESEL TK#SA004U001 2 3 4 El I60300 JAN 17, 2011 2:58 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 DIESEL TK#SA004U001 1 2 2 3 3 4 4 160400 JAN 17, 2011 2:58 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA004U001 20149 2 0 3 0 4 0 ❑ I60700 JAN 17, 2011 2:58 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA004U001 114.00 2 0.00 3 0.00 4 0.00 El I60900 JAN 17, 2011 2:58 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 DIESEL TK#SA004U001 0.000450 2 0.000000 3 0.000000 4 0.000000 I61200 JAN 17, 2011 2:58 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 DIESEL TK#SA004U001 NONE NONE 2 NONE NONE 3 NONE NONE 4 NONE NONE ❑ El I62100 JAN 17, 2011 2:58 PM TANK LOW PRODUCT LIMIT TANK' PRODUCT LABEL GALLONS 1 DIESEL TK#SA004U001 12000 2 0 3 0 4 0 162200 JAN 17, 2011 2:58 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA004U001 19141 2 0 3 0 4 0 162300 JAN 17, 2011 2:58 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA004U001 18134 2 0 3 0 4 0 ❑ 162400 JAN 17, 2011 2:58 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA004U001 2.0 I62800 JAN 17, 2011 2:58 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA004U001 20149 2 0 3 0 4 0 162900 JAN 17, 2011 2:58 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA004U001 12000 2 0 3 0 4 0 ❑ 170300 JAN 17, 2011 2:58 PM LIQUID TYPE SENSOR LOCATION TYPE 1 ANNULAR SPACE TRI-STATE (SINGLE FLOAT) 2 FILL SUMP TRI-STATE (SINGLE FLOAT) 3 PIPING SUMP TRI-STATE (SINGLE FLOAT) 4 TRANSITION SUMP TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) ❑ 8 TRI-STATE (SINGLE FLOAT) I90200 JAN 17, 2011 2:58 PM SOFTWARE REVISION LEVEL VERSION 123.01 SOFTWARE# 346123-100-B CREATED - 02.06.21.13.00 S-MODULE# `330160-002-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS . ANNUAL IN-TANK TESTS CSLD Fl I11100 JAN 17, 2011 2:58 PM BKFDCAI2 SA004 1918 M ST. BAKERSFIELD,CA 93301 661-631-2540 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME I 1 INPUT GENERATOR RUN EXTERN INPUT ALARM CLEAR 1-17-11 11:40AM I 1 INPUT GENERATOR RUN EXTERN INPUT ALARM ALARM 1-17-11 11:35AM T 1 TANK DIESEL TK#SA0040001 SUDDEN LOSS ALARM CLEAR 1-13-11 11:56AM T 1 TANK DIESEL TK#SA004U001 SUDDEN LOSS ALARM ALARM 1-13-11 11:55AM T 1 TANK DIESEL TK#SA004UO01 SUDDEN LOSS ALARM CLEAR 1-13-11 11:55AM T 1 TANK DIESEL TK#SA004U001 SUDDEN LOSS ALARM ALARM 1-13-11 10:18AM T 1 TANK DIESEL TK#SA004U001 HIGH WATER ALARM CLEAR 1-13-11 10:18AM T 1 TANK DIESEL TK#SA004U001 LOW PRODUCT ALARM CLEAR 1-13-11 10:18AM T 1 TANK DIESEL TK#SA004UO01 PROBE OUT CLEAR 1-13-11 10:17AM T 1 TANK DIESEL TK#SA004U001 PROBE OUT ALARM 1-13-11 10:16AM T 1 TANK DIESEL TK#SA004O001 HIGH WATER ALARM ALARM 1-13-11 10:08AM T 1 TANK DIESEL TK#SA004O001 OVERFILL ALARM CLEAR 1-13-11 10:05AM T 1 TANK DIESEL TK#SA004O001 LOW PRODUCT ALARM ALARM 1-13-11 10:OOAM T 1 TANK DIESEL TK#SA004U001 OVERFILL ALARM ALARM 1-13-11 9:59AM T 1 TANK DIESEL TK#SA004U001 LOW PRODUCT ALARM CLEAR 1-13-11 9:58AM T 1 TANK DIESEL TK#SA004UO01 SUDDEN 'LOSS ALARM CLEAR 1-13-11 9:58AM T 1 TANK DIESEL TK#SA004U001 LOW PRODUCT ALARM ALARM 1-13-11 9:58AM T 1 TANK DIESEL TK#SA004UO01 PROBE OUT CLEAR 1-13-11 9:57AM T 1 TANK DIESEL TK#SA004U001 PROBE OUT ALARM 1-13-11 9:55AM T 1 TANK DIESEL TK#SA004UO01 SUDDEN LOSS ALARM ALARM 1-13-11 9:55AM L 4 OTHER TRANSITION SUMP FUEL ALARM CLEAR 1-13-11 9:52AM L 4 OTHER TRANSITION SUMP FUEL ALARM ALARM 1-13-11 9:50AM L 4 OTHER TRANSITION SUMP FUEL ALARM CLEAR 1-13-11 9:50AM L 4 OTHER TRANSITION SUMP FUEL ALARM ALARM 1-13-11 9:50AM L 1 ANNULAR ANNULAR SPACE FUEL ALARM CLEAR 1-13-11 9:42AM L 1 ANNULAR ANNULAR SPACE FUEL ALARM ALARM 1-13-11 9:35AM L 2 OTHER FILL SUMP FUEL ALARM CLEAR 1-13-11 9:35AM L 2 OTHER FILL SUMP FUEL ALARM ALARM 1-13-11 9:28AM L 3 STP SUMP PIPING SUMP FUEL ALARM CLEAR 1-13-11 9:26AM L 3 STP SUMP PIPING SUMP FUEL ALARM ALARM 1-13-11 9:21AM I 1 INPUT GENERATOR RUN EXTERN INPUT ALARM CLEAR 10-18-10 12:11AM I 1 INPUT GENERATOR RUN EXTERN INPUT ALARM ALARM 10-18-10 12:06AM I 1 INPUT GENERATOR RUN EXTERN INPUT ALARM CLEAR 7-20-10 11:28AM I 1 INPUT GENERATOR RUN EXTERN INPUT ALARM ALARM 7-20-10 11:23AM L 2 OTHER FILL SUMP FUEL ALARM CLEAR 4-23-10 9:04AM L 2 OTHER FILL SUMP FUEL ALARM ALARM 4-22-10 2:15AM T 1 TANK DIESEL TK#SA004U001 LEAK ALARM CLEAR 4-04-10 3:53PM T 1 TANK DIESEL TK#SA004U001 SUDDEN LOSS ALARM CLEAR 4-04-10 3:53PM T 1 TANK DIESEL TK#SA004U001 PROBE OUT CLEAR 4-04-10 3:52PM T 1 TANK DIESEL TK#SA004U001 PROBE OUT ALARM 4-04-10 3:51PM T 1 TANK DIESEL TK#SA004U001 LEAK ALARM ALARM 4-04-10 3:50PM T 1 TANK DIESEL TK#SA004UO01 PROBE OUT CLEAR 4-04-10 3:48PM T 1 TANK DIESEL•TK#SA004U001 PROBE OUT ALARM 4-04-10 3:47PM T 1 TANK DIESEL TK#SA004U001 SUDDEN LOSS ALARM ALARM 4-04-10 3:46PM I 1 INPUT GENERATOR RUN EXTERN INPUT ALARM CLEAR 4-02-10 8:03AM I 1 INPUT GENERATOR RUN EXTERN INPUT ALARM ALARM 4-02-10 7:58AM T 1 TANK DIESEL TK#SA004O001 HIGH WATER ALARM CLEAR 1-28-10 11:31AM T 1 TANK DIESEL TK#SA004U001 PROBE OUT CLEAR 1-28-10 11:31AM T 1 TANK DIESEL TK#SA004UO01 PROBE OUT ALARM 1-28-10 11:29AM T 1 TANK DIESEL TK#SA0040001 HIGH WATER ALARM ALARM 1-28-10 11:21AM I11200 JAN 17, 2011 2:59 PM BKFDCAI2 SA004 1918 M ST. BAKERSFIELD,CA 93301 661-631-2540 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL TK#SA004U001 LOW TEMP WARNING CLEAR 1-13-11 10:18AM T 1 TANK DIESEL TK#SA004U001 HIGH WATER WARNING CLEAR 1-13-11 10:18AM T 1 TANK DIESEL TK#SA004UO01 LOW TEMP WARNING ALARM 1-13-11 10:18AM T 1 TANK DIESEL TK#SA004UO01 DELIVERY NEEDED CLEAR 1-13-11 10:18AM T 1 TANK DIESEL TK#SA004U001 HIGH WATER WARNING ALARM 1-13-11 10:08AM T 1 TANK DIESEL TK#SA004U001 DELIVERY NEEDED A00'U0❑$11Lkl3-11 10:00AM T 1 TANK DIESEL TK#SA0040001 DELIVERY NEEDED CLEAR 1-13-11 9:58AM T 1 TANK DIESEL TK#SA004UO01 INVALID FUEL LEVEL CLEAR 1-13-11 9:58AM T 1 TANK DIESEL TK#SA004U001 DELIVERY NEEDED ALARM 1-13-11 9:58AM T 1 TANK DIESEL TK#SA004U001 INVALID FUEL LEVEL ALARM 1-13-11 9:57AM T 1 TANK DIESEL TK#SA004UO01 LOW TEMP WARNING CLEAR 4-04-10 4:12PM T 1 TANK DIESEL TK#SA004UO01 LOW TEMP WARNING ALARM 4-04-10 3:50PM T 1 TANK DIESEL TK#SA004UO01 HIGH WATER WARNING CLEAR 1-28-10 11:31AM T 1 TANK DIESEL TK#SA004UO01 LOW TEMP WARNING CLEAR 1-28-10 11:31AM T 1 TANK DIESEL TK#SA004UO01 LOW TEMP WARNING ALARM 1-28-10 11:31AM T 1 TANK DIESEL TK#SA004UO01 HIGH WATER WARNING ALARM 1-28-10 11:21AM L 2 OTHER FILL SUMP LIQUID WARNING CLEAR 1-28-10 10:24AM L 2 OTHER FILL SUMP LIQUID WARNING ALARM 1-28-10 10:19AM SYSTEM PRINTER ERROR CLEAR 1-04-10 9:53AM SYSTEM PAPER OUT CLEAR 1-04-10 9:53AM SYSTEM PAPER OUT ALARM 1-04-10 9:53AM SYSTEM PRINTER ERROR ALARM 1-04-10 9:53AM SYSTEM PRINTER ERROR CLEAR 1-04-10 9:52AM SYSTEM PAPER OUT CLEAR 1-04-10 9:52AM SYSTEM PRINTER ERROR ALARM 12-30-09 3:52PM SYSTEM PAPER OUT ALARM 12-30-09 3:52PM SYSTEM PRINTER ERROR CLEAR 2-18-09 10:51AM SYSTEM PRINTER ERROR ALARM 2-18-09 10:51AM T 1 TANK DIESEL TK#SA004UO01 HIGH PRODUCT ALARM CLEAR 2-18-09 10:30AM T 1 TANK DIESEL TK#SA004UO01 HIGH PRODUCT ALARM ALARM 2-18-09 10:30AM L 2 OTHER FILL SUMP LIQUID WARNING CLEAR 2-16-09 10:17AM L 2 OTHER FILL SUMP LIQUID WARNING ALARM 2-18-09 10:13AM SYSTEM PRINTER ERROR CLEAR 12-30-08 11:21AM SYSTEM PRINTER ERROR ALARM 12-30-08 11:21AM SYSTEM PRINTER ERROR CLEAR 12-30-08 11:21AM SYSTEM PRINTER ERROR ALARM 12-30-08 11:21AM SYSTEM PRINTER ERROR CLEAR 12-30-08 11:21AM SYSTEM PAPER OUT CLEAR 12-30-08 11:21AM SYSTEM PRINTER ERROR ALARM 12-28-08 9:09PM SYSTEM PAPER OUT ALARM 12-28-08 9:09PM SYSTEM PRINTER ERROR CLEAR 12-17-08 10:34AM SYSTEM PRINTER ERROR ALARM 12-17-08 10:34AM SYSTEM PRINTER ERROR CLEAR 10-23-08 3:08PM SYSTEM PRINTER ERROR ALARM 10-23-08 3:08PM SYSTEM PRINTER ERROR CLEAR 10-23-08 3:07PM SYSTEM PAPER OUT CLEAR 10-23-08 3:07PM SYSTEM PRINTER ERROR ALARM 10-23-08 8:OOAM SYSTEM PAPER OUT ALARM 10-23-08 8:00AM SYSTEM PRINTER ERROR CLEAR 8-11-08 9:45AM SYSTEM PAPER OUT CLEAR 8-11-08 9:45AM 120600 JAN 17, 2011 2:59 PM BKFDCA12 SA004 1918 M ST. BAKERSFIELD,CA 93301 661-631-2540 TANK ALARM HISTORY TANK 1 DIESEL TK#SA004UO01 SETUP DATA WARNING APR 21, 2004 8:51 AM APR 21, 2004 8:34 AM APR 21, 2004 8:28 AM LEAK ALARM APR 4, 2010 3:50 PM APR 14, 2004 9:35 AM HIGH WATER ALARM JAN 13, 2011 10:08 AM JAN 28, 2010 11:21 AM OVERFILL ALARM JAN 13, 2011 9:59 AM JAN 28, 2010 11:06 AM MAY 7, 2008 1:54 PM LOW PRODUCT ALARM JAN 13, 2011 10:00 AM JAN 13, 2011 9:58 AM MAY 6, 2008 2:45 PM SUDDEN LOSS ALARM JAN 13, 2011 11:55 AM JAN 13, 2011 10:18 AM JAN 13, 2011 9:55 AM HIGH PRODUCT ALARM FEB 18, 2009 10:30 AM FEB 27, 2008 10:29 AM MAR 15, 2007 9:05 AM INVALID FUEL LEVEL JAN 13, 2011 9:57 AM MAY 6, 2008 2:43 PM PROBE OUT JAN 13, 2011 10:16 AM JAN 13, 2011 9:55 AM APR 4, 2010 3:51 PM HIGH WATER WARNING JAN 13, 2011 10:08 AM JAN 28, 2010 11:21 AM DELIVERY NEEDED JAN 13, 2011 10:00 AM JAN 13, 2011 9:58 AM MAY 6, 2008 2:45 PM MAX PRODUCT ALARM MAR 29, 2006 9:32 AM LOW TEMP WARNING JAN 13, 2011 10:18 AM APR 4, 2010 3:50 PM JAN 28, 2010 11:31 AM I30200 JAN 17, 2011 3:00 PM BKFDCA12 SA004 1918 M ST. BAKERSFIELD,CA 93301 661-631-2540 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 ANNULAR SPACE JAN 13, 2011 9:35 AM FUEL ALARM JAN 28, 2010 10:37 AM FUEL ALARM FEB 18, 2009 10:21 AM FUEL ALARM 2 FILL SUMP JAN 13, 2011 9:28 AM FUEL ALARM APR 22, 2010 2:15 AM FUEL ALARM JAN 28, 2010 10:43 AM FUEL ALARM 3 PIPING SUMP JAN 13, 2011 9:21 AM FUEL ALARM JAN 28, 2010 10:50 AM FUEL ALARM FEB 18, 2009 10:05 AM FUEL ALARM 4 TRANSITION SUMP JAN 13, 2011 9:50 AM FUEL ALARM JAN 13, 2011 9:50 AM FUEL ALARM JAN 28, 2010 10:55 AM FUEL ALARM TAiT Rt5IN4�Q TH!CHAW"Of 2131 S. Dtupotij Drive, Annhcirn,CA 928 06 p:714i560;8222 w,toi t:com January 20, 2011 VIA FED EX: 7966 8023 9715 Bakersfield Fire Department 2101 H Street Bakersfield CA 93301 Re: Monitoring System Certification Spill Bucket Testing Product Line Testing Pacific Bell Telephone Co. dba AT&T California 1918 "M" STREET, BAKERSFIELD, CA GEOPAR: SA004 To Whom It May Concern: Enclosed are the results for the following tests completed on January 13, 2011: ■ Monitoring System Certification Report Form ■ Spill Bucket Testing Report Form ■ Product Line Testing Report Form Please do not hesitate to call me if you have any questions. Truly Yours, I h . Denison Program Manager CA iica 588098 A2 llc#095984 i NV lica 0049666 i TX lira CR0000041