HomeMy WebLinkAboutUST-TEST RESULTS 7/22/2010 CONFIDENCE UST SERVICES, INC. 417 Montclair Street,Bakersfield,CA 93309 800339-9930 or 891-831-3870 : FINAL TEST RESULTS : IIIIIIIIIIIIIIIIIIII 69 ALERT 1000 / ALERT 1050 / TEI LT-3/ IE CUSTOMER ADDRESS: WORK ORDER:23833 SITE ADDRESS: Sullivan's Petroleum Co. Downtown Chevron 1508-18th Street Ste.222 TEST DATE: 7/22/2010 2317 "L" Street Bakersfield, CA 93301 Bakersfield, CA 93301 SITE CONTACT:Frank Sullivan PHONE NUMBER:3 2 7-5 0 0 8 TECHNICIAN: Doug Young PHONE NUMBER:800-339-9930 LICENSE: 901076 WATER IN BACKFILL: N/A DATE & TIME OF LAST FUEL DELIVERY:N/A TANK INFORMATION: (WETTED) TANK 1 TANK 2 TANK 3 TANK 4 PRODUCT TYPE: Diesel All Disp. TOTAL GALLONS: PRODUCT LEVEL: PERCENT FULL: TEST METHOD: WATER IN TANK: TANK MATERIAL: P.S.I.@ BOTTOM: TEST DURATION: FINAL LEAK RATE: TEST RESULT: TANK INFORMATION: ALERT 1050X ALERT 1050X ALERT 1050X ALERT 105OX (ULLAGE)U/F ONLY ULLAGE GALLONS: START PRESSURE: END PRESSURE: TEST RESULT: PRODUCT LINES: TEI LT-3 TEI LT-3 TEI LT-3 TEI LT-3 LINE TYPE: Pressure START TIME: 2:30pm END TINE: 2:45pm TEST PRESSURE: 55 psi FINAL LEAK RATE: -0.05 gph TEST RESULT: FAIL MECHANICAL LEAK DETECTORS: Red Jacket FXT Red Jacket FXT Red Jacket FXT Red Jacket FXT MODEL: SERIAL NUMBER: CHECK VALVE PSI: BLEED OFF ml: LEAK RATE TESTED: TEST RESULT: A) These a stems and methods meet or exceed the criteria in USEPA 40CFR parts 280, NFPA 329-87 and all applic sta codes. B) Any f ilu li;red above may re ire further action, check with all regulatory agencies. Techni n ure: Date: Manufacturer Cer� fication No: an or uglas m. Young III 7-2Z ' Alert: 2004040 TEI: LT-3, 089 IIIIIIIIIIIIIIIIIIII 70 IE CONFIDENCE UST SERVICES, INC. 417 Montclair Street,Bakersfield,CA 83308 800-338-9830 or 881-631-3870 : FINAL TEST RESULTS : ALERT 1000 / ALERT 1050 / TEI LT-3 CUSTOMER ADDRESS: WORK ORDER:23833 SITE ADDRESS : Sullivan's Petroleum Co. Downtown Chevron 1508-18th Street Ste.222 TEST DATE: 7/23/2010 2317 "L" Street Bakersfield, CA 93301 Bakersfield, CA 93301 SITE CONTACT:Frank Sullivan PHONE NUMBER:3 2 7-5 0 0 8 TECHNICIAN: Doug Young PHONE NUMBER:800-339-9930 LICENSE: 901076 WATER IN BACKFILL: N/A DATE & TIME OF LAST FUEL DELIVERY:N/A TANK INFORMATION: (WETTED) TANK 1 TANK 2 TANK 3 TANK 4 PRODUCT TYPE• Diesel south Line TOTAL GALLONS: PRODUCT LEVEL: PERCENT FULL: TEST METHOD: WATER IN TANK: TANK MATERIAL: P.S.I.@ BOTTOM: TEST DURATION: FINAL LEAK RATE: TEST RESULT: TANK INFORMATION: ALERT 1050X ALERT 1050X ALERT 1050X ALERT 105OX (ULLAGE) U/F ONLY ULLAGE GALLONS: START PRESSURE: END PRESSURE: TEST RESULT: PRODUCT LINES: TEI LT-3 TEI LT-3 TEI LT-3 TEI LT-3 LINE TYPE• Pressure START TIME: 8:45 am END TIME: 9:00 am TEST PRESSURE- 55 psi FINAL LEAK RATE: -0.004 gph TEST RESULT: PASS MECHANICAL LEAK DETECTORS: Red Jacket FXT Red Jacket FXT Red Jacket FXT Red Jacket FXT MODEL: SERIAL NUMBER: CHECK VALVE PSI: BLEED OFF ml: LEAK RATE TESTED: TEST RESULT: A) These systems and methods meet or exceed the criteria in USEPA 40CFR parts 280, NFPA 329-87 and all applicable state codes. S) Any fa' re list,adl above may require further action, check with all regulatory agencies. Technic' n i Date: Manufacturer Certification No: an or Young zzz 7-Z3-Za/0 Alert: 2004040 TEI: LT-3, 089