HomeMy WebLinkAbout2010 FMC RESULTS MONITORING SYSTEM CERTIFICATION Pass For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of this date. A. General Information IIIIIIIIIIIIIIIIIIII 01 Facility Name: #347 Fastrip#26 IE Bldg.No.: Site Address: 2698 Oswell Street City: Bakersfield Zip: 93306 Facility Contact Person: Omero Garcia Contact Phone No.: 661-393-7000 Make/Model of Monitoring System: Gilbarco EMC Date of Testing/Servicing: 8/11/2010 B. Inventory of Equipment Tested/Certified es Check the appropriate box to care specific equipment innpecteWseniced: Tank ID: 12000 gal.Regular 1 Tank ID: 12000 gal.Regular 2 [X] In-Tank Gauging Probe. Model:847390-107 [x] In-Tank Gauging Probe. Model:847390-107 [x] Annular Space or Vault Probe. Model:794390-420 [x] Annular Space or Vault Sensor. Model:794390-420 [x] Piping Sump/Trench Sensor(s). Model:794380-208 [x] Piping Sump/Trench Sensor(s). Model: 794380-208 ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s). Model: [J Mechanical Line Leak Detector. Model:FX1V ❑ Mechanical Line Leak Detector. Model: NIA ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: U Tank Overfill/High Level Sensor. Model:847390-107 U Tank Overfill/High Leval Sensor. Model: 847390-107 ❑ Other(specify equip.type and model in Sec. E on Pg.2) ❑ Other(specify equip.type and model in Sec. E on Pg.2) Tank ID: 12000 gal.Super Tank ID: 12000 gal. Diesel [x] In-Tank Gauging Probe. Model:847390-107 [x] In-Tank Gauging Probe. Model: 847390-107 [x] Annular Space or Vault Sensor. Model-794390-420 [x] Annular Space or Vault Sensor. Model: 794390420 [X] Piping Sump/Trench Sensor(s). Model:794380-208 [x] Piping Sump/Trench Sensor(s). Model: 794380-208 ❑ Fill Sump Sensors(s). Model: ❑ Fill Sump Sensor(s). Model: [xx] Mechanical Line Leak Decector. Model:FX1V [x] Mechanical Line Leak Detector. Model: FX1DV ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: [x] Tank Overfill/High Level Sensor. Model:847390-107 U Tank Overfill/High Level Sensor.Model:847390-107 ❑ Other(specify equip.type and model in Sec. E on Pg.2) ❑ Other(specify equip,typs and model in Sec. E on Pg.2) Dispenser ID: 1 &2 Dispenser ID: 3&4 Ex-1 Dispenser Containment Sensor(s). Model: 794380-208 [x] Dispenser Containment Sensor(s). Model: 794380-208 [X] Shear Valve(s). [x] Shear Valve(s). ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s) Dispenser ID: 5&6 Dispenser ID: 7&8 [x] Dispenser Containment Sensor(s). Model: 794380-208 [x] Dispenser Containment Sensor(s). Model: 794380-208 [x] Shear Valve(s). U Shear Valve(s). ❑ Dispenser Containment Float(s)and Chains(s). ❑ Dispenser Containment Float(s)and Chain(s). Dispenser ID: North Transition Sump Dispenser ID: South Transition Sump [x1 Dispenser Containment Sensor(s). Model: 794380-208 [X] Dispenser Containment Sensor(s). Model: 794380-208 ❑ Shear Valve(s). ❑ Shear Valve(s). ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s). If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. C. Certification -I certify that the equipment identified in this document was inspected/services in accordance with the manufacturers'guidlines.Attached to this Certification is information(e.g.manufacturers'checklist)necessary to varify that this information is correct and a plot plan showing the layout of monitoring equipment.For equipment capable of enerating such reports,I have attached a copy of the report; (check all that apply) ❑x S tem Set-up [x]Al his ry report Technician Name(print): Bryan A Self Signature: l/`- Certification No: 837501 License No:8049 Testing Company Name: Confidence UST Services,Inc. Phone No: 800-339-9930 Site Address: 2698 Oswell Street,Bakersfield,CA 93306 IIIIIIIIIIIIIIIIIIII _Date of Testing/Servicing: 8111/2010 02 IE D.Results of Testing/Servicing Software Version Installed: 327.04 Complete the following checklist: L] Yes ❑ No* Is the audible alarm operational? • Yes No* Is the Visual alarm operational? • Yes No* Were all sensors visually inspected. x Yes ❑ No* Were all sensors installed at the lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) Hx N/A operational? [XI Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary ❑N/A containment monitoring system detects a leak,fails to operate, or is electrically disconnected?If yes: which sensors initate positive shut-down? E Sump/Trench Sensors[x]Dispenser Containment Sensors Did you confirm positive shut-down due to leaks and sensor failure/disconnected? ❑ Yes; L] No; ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no L]N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visual and audible at the tank fill point(s)and operating properly?If so,at what percent of tank capasity does the alarm trigger? 9p % ❑ Yes* U No Was any monitoring equipment rep ace ? If Yes, identify specific sensors,probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. ❑ Yes* X No Was liquid found inside any secondary containment systems designed as dry systems? ❑Product; ❑ Water. If yes,describe causes in Section E,below. x * I Was monitoring system set-up reviewed to ensure proper settings? *In Section E below,describe how and when these deficiencies were or will be corrected. E. Comments: r F. In-Tank Guaging/SIR Equipment: ❑ Check this box if tank guaging is used only for inventory control. ❑ Check this box if tank guaging or SIR equipment is installed. This section must be completed if in-tank guaging equipment is used to perform leak detection monitoring. Complete the following checklist: Fxj Yes ❑ No* Has all input wiring been inspected for proper enter and term ination,including testing for ground faults? x Yes 7 No* Were all tank guaging probes visually inspected for damage and residue buildup? x Yes No* Was accuracy of system product level readings tested? x Yes No* Was accuracy of system water level readings tested? L[x] Yes No* Were all probes reinstalled properly? L] Yes ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H,below,describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): ❑ Check this box if LLD's are not installed. Complete the following checklist: Lx] Yes ❑ No* For equip. start-up or annual equipment certification,,was a leak simulated to varify LLD performance? (Check all that apply) Simulated leak rate: [X]3 g.p.h.: 00.1 g.p.h.; 00.2 g.p.h.; [X] Yes No* Were all LLD's confirmed operational and accurate within regulatory requirments? x Yes No* Was the testing apparatus properly calibrated? Yes No* For machanical LLD's,does the LLD restrict product ow if it detects a leak? N/A ❑ Yes No* For electronic LLD's,does the turbine automatically shut off if the LLD detects a leak? Cx] N/A ❑ Yes No* For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system is [x] N/A disabled or disconnected? ❑ Yes No* For electronic LLD's,does the turbine automatically shut off if any portion of the monitoring system [X] N/A malfunction or fails a test? ❑ Yes D No* For electronic LLD's,have all accessible wiring connections been visually inspected? [X] N/A x Yes No Were all items on the equipment manufacturer's maintenance checklist completed? * In the section H,below,describe how and when these deficiencies were or will be corrected. H. Comments: FASTRIP 347 COMMUNICATIONS SETUP 2698 OSWELL ST. SYSTEM SETUP - - - - - - - - - - - - BAK.ERSFIELD.CA93306 -AUG 11. 2010 9:11 661-872-8781 PORT SETTINGS: AUG 11 , 2010 9: 10 AM SYSTEM UNITS COMM BOARD : 1 (ED1M ) RS-232 SECURITY U.S. CODE : DISABLED SYSTEM STATUS REPORT SYSTEM LANGUAGE ENGLISH COMM BOARD 2 (RS-232) ALL FUNCTIONS NORMAL SYSTEM DATE/TIME FORMAT BAUD RATE 9600 MON DD YYYY HH:MM:SS xM PARITY NONE INVENTORY REPORT FASTRIP 347 STOP BIT — 1 STOP 2698 OSWELL ST. DATA LENGTH: 8 DATA SCURITY T 1 :UNL 1 BAKERSFIELD.CA93306 -ODES: DISABLED VOLUME - 8349 GALS 661-872-8781 ULLAGE = 3651 GALS COMM BOARD 3 (RS-232) 90% ULLAGE= 2451 GALS SHIFT TIME 1 6:00 AM BAUD RATE 9600 TC VOLUME = 8235 GALS SHIFT TIME 2 DISABLED PARITY NONE HEIGHT = 63.01 INCHES SHIFT TIME 3 DISABLED STOP BIT 1 STOP WATER VOL = 0 GALS SHIFT TIME 4 DISABLED DATA LENGTH: 8 DATA WATER - 0.00 INCHES TANK PER TST NEEDED WRN RS-232 SECURITY TEMP = 79.5 DEG F DISABLED CODE : DISABLED TANK ANN TST NEEDED WRN T 2:DIESEL DISABLED AUTO TRANSMIT SETTINGS: VOLUME = 6580 GALS LINE RE-ENABLE METHOD ULLAGE = 5420 GALS PASS LINE TEST AUTO LEAK ALARM LIMIT 90% ULLAGE= 4'220 GALS i DISABLED TC VOLUME = 6492 GALS AUTO HIGH WATER LIMIT HEIGHT = 51 .65 INCHES LINE PER TST NEEDED WRN DISABLED WATER VOL = 21 GALS DISABLED AUTO OVERFILL LIMIT WATER = 0.99 INCHES LINE ANN TST NEEDED WRN DISABLED TEMP = 89.6 DEG F DISABLED AUTO LOW PRODUCT PRINT TC VOLUMES DISABLED ENABLED AUTO THEFT LIMIT T 3:PNL DISABLED VOLUME x 6460 GALS AUTO DELIVERY START ULLAGE _ .5540 GALS TEMP COMPENSATION DISABLED 90°5 ULLAGE= 4340 GALS VALUE (DEG F ) : 60.0 AUTO DELIVERY END TG VOLUME_ 6338 GALS STICK HEIGHT OFFSET DISABLED HEIGHT - = O::_(3'9_INCHES DISABLED AUTO EXTERNAL INPUT ON WATER VOL = 0 GALS ULLAGE: 90% DISABLED WATER = 0.00 INC_,HES AUTO EXTERNAL INPUT OFF TEMP = 87.0 DEG F H-PROTOCOL DATA FORMAT DISABLED HEIGHT AUTO SENSOR FUEL ALARM DAYLIGHT SAVING TIME DISABLED T 4:UNL 2 ENABLED AUTO SENSOR WATER ALARM VOLUME = 6815 GALS START DATE DISABLED ULLAGE = 5185 GALS MAR WEEK 2 SUN AUTO SENSOR OUT ALARM 90% ULLA(:'E= 3985 GALS START TIME DISABLED TC VOLUME = 6729 GALS 2:00 AM HEIGHT = 53.13 INCHES END DATEEK 1 SUN WATER VOL = 63 GALS END TIME WATER = 2.07 INCHES 2:00 AM TEMP = 77.8 DEG F RE-DIRECT LOCAL PRINTOUT x * n END * * * DISABLED E RS-232 END OF MESSAGE URO PROTOCOL PREFIX S DISABLED SYSTEM SECURITY CODE : 000000 MAINTENANCE HISTORY DISABLED TANK CHART SECURITY DISABLED CUSTOM ALARMS DISABLED MASS/DENSITY DISABLED T 2:D1ESEL T 3:PNL IN SETUP PRODUCT CODE 2 PRODUCT CODE 3 THERMAL COEFF : .000450 THERMAL COEFF : .000700 TANK. DIAMETER 96.00 TANK DIAMETER 96.00 T 1 :UNL 1 TANK PROFILE 1 PT TANK PROFILE VOL : 12000 PRODUCT CODE 1 FULL VOL 12000 THERMAL COEFF : .000700 TANK DIAMETER 96.00 TANK PROFILE 1 PT FLOAT SIZE: 4.0 IN. FLOAT SIZE: 4.0 1N. FULL VOL 12000 WATER WARNING 2.0 WATER WARNING = 2.0 HIGH WATER LIMIT: 3.0 HIGH WATER LIMIT: 3.0 FLOAT SIZE: 4.0 IN. MAX OR LABEL VOL: 12000 MAX OR LABEL VOL: 12000 MATER WARNING �,p OVERFILL LIMIT 90% OVERFILL LIMIT 10800 HIGH WATER LIMIT: 3.0 HIGH PRODUCT 1080 HIGH PRODUCT 95% MAX OR LABEL VOL: 12000 11400 OVERFILL LIMIT 90% DELIVER! LIMIT 11450 DELIVERY LIMIT 1800 10800 1800 HIGH PRODUCT 95% LOW PRODUCT 1200 LOW PRODUCT 1200 11400 LEAK ALARM LIMIT: 99 LEAK ALARM LIMIT: 99 DELIVERY LIMIT 15% SUDDEN LOSS LIMIT: 99 SUDDEN LOSS LIMIT: 99 1600 TANK TILT 0.00 TANK TILT 0.00 PROBE OFFSET 0.00 LOW PRODUCT 1200 PROBE OFFSET 0.00 LEAK ALARM LIMIT: 99 SUDDEN LOSS LIMIT: 99 SIPHON MANIFOLDED TANKS SIPHON MANIFOLDED TANKS TANK TILT 0.00 Tit: NONE Tit: NONE PROBE OFFSET 0.00 LINE MANIFOLDED TANKS LINE MANIFOLDED TANKS Tit: NONE Tit: NONE SIPHON 11AN I FOLIiED TANKS Tit: NONE LEAK MIN PERIODIC: I% LEAK MIN PERIODIC: 1% LINE MANIFOLDED TANKS 120 120 Ttt: NONE PERIODIC TEST TYPE PERIODIC TEST TYPE STANDARD STANDARD LEAK MIN PERIODIC: I% PERIODIC TEST FAIL PERIODIC: TEST FAIL 120 ALARM DISABLED ALARM DISABLED PERIODIC TEST TYPE STANDARD GROSS TEST FAIL GROSS TEST FAIL PERIODIC TEST FAIL ALARM DISABLED ALARM DISABLED ALARM DISABLED PER TEST AVERAGING: OFF PER TEST AVERAGING: OFF GROSS TEST FAIL TANK TEST NOTIFY: OFF TANK TEST NOTIFY: OFF ALARM DISABLED PER TEST AVERAGING: .'.:.OFF TNK TST SIPHON BREAK:OFF TNK TST SIPHON BREAK:OFF TANK TEST NOTIFY: OFF DELIVERY DELAY 1 MIN PUMPVT THRESHOLD 10.00% ' PUMP THRESHOLD 10.00% TNY TST SIPHON BREAK:OFF DELIVERY DELAY 1 MIN PUMP THRESHOLD 10,00% T 4:UNL 2 LIQUID SENSOR SETUP PRODUCT CODE 4 PUMP SENSOR SETUP THERMAL COEFF : .000700 - - - - - - - - - - - - _ _ _ _ _ _ TANK DIAMETER 96.00 L 1 :UNL 1 STP - - _ - - TANK PROFILE PT TRI-STATE (SINGLE FLOAT) S 1 :UNL 1 FULL LE LL VOL 12000 CATEGORY STP SUMP TANK 0: 1 DISPENSE MODE: FLOAT SIZE: 4.0 IN. STANDARD L 2:UNL 1 ANN L S 2:pN WATER WARNING 2.0 TRI-STATE (SINGLE FLOAT) TANK N 3 HIGH WATER LIMIT: 3.0 CATEGORY ANNULAR SPACE DISPENSE MODE: MAX OR LABEL VOL: 12000 STANDARD OVERFILL LIMIT 90% L 3:DSL STP 10800 TRI-STATE( SINGLE FLOAT) 114400 HIGH PRODUCT 95% CATEGORY : STP SUMP DELIVERY LIMIT 15% 1800 L 4:DSL ANN LOW PRODUCT 1200 TRI-STATE (SINGLE FLOAT) LEAK ALARM LIMIT: 99 CATEGORY : ANNULAR SPACE SUDDEN LOSS LIMIT: 99 TANK TILT 0.00 OUTPUT RELAY SETUP PROBE OFFSET 0.00 L 6:PNL ANN - - - - - - - - - - - " TRI-STATE (SINGLE FLOAT) R 1 :UNL 1 SIPHON MANIFOLD£D TANKS CATEGORY ANNULAR SPACE IN TYPE: LINE NONE S PUMP CONTROL OUTPUT L NAN I FOLDED TANK, ri: 1 T#: NONE L 7:UNL 2 STP TANK PERIODIC: E ( FLOAT) LEAK MIN 1 CATEGORY : STP SUMP LIQUID SE 1VSOR ALMS L 1 :FUEL ALARM PEkIOUIC TEST TYPE 120 L 7:FUEL ALARM STANDARD L B:UNL 2 ANN L 9:FUEL ALARM TRI-STATE (SINGLE FLOAT) L11 :FUEL ALARM ' PERIODIC TEST FAIL CATEGORY ANNULAR SPACE L12:FUEL ALARM ALARM DISABLED L 1 :SENSOR OUT ALARM GROSS TEST FAIL L 7:SENSOR OUT ALARM ALARM DISABLED L 9:DISP 1-2 L 9:SENSOR OUT ALARM TRI-STATE (SINGLE FLOAT) LIO:SENSOR OUT ALARM PER TEST AVERAGING: OFF CATEGORY : DISPENSER PAN L11 :SENSOR OUT ALARM L12:SENSOR OUT ALARM L I :SHORT ALARM TANK TEST NOTIFY: OFF L 7:SHORT ALARM L10:DISP 3-4 L 9:SHORT ALARM TIVK TST SIPHON bREF,k;_:OFF TRI-STATE (SINGLE FLOAT) L 10:SHORT ALARM DELIVERY DELAY 1 MIN CATEGORY : DISPENSER PAN L11 :SHORT ALARM PUMP THRESHOLD 10.00% L12:SHORT ALARM ISD SITE ALARMS LII :DISP 5-6 ISD GROSS PRES FAIL TRI-STATE (SINGLE FLOAT) ISD DEGRD LEAK FAIL CATEGORY : DISPENSER PAM ISD VP PRES FAIL ISD VP STATUS FAIL L12:DISP 7-8 ISD HOSE ALARMS TRI-STATE (SINGLE FLOAT) ALL:GROSS COLLECT FAIL CATEGORY : DISPENSER PAN ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL LEAK TEST METHOD TEST ON DATE. : ALL TANK L13:TRANS SUMP NO. FEB 6, 2007 TRI-STATE (SINGLE FLOAT) START TIME : DISABLED CATEGORY DISPENSER PAN TEST RATE :0.20 GAL;HR DURATION : 2 HOURS TST EARLY STOP:DISABLED L14:TRANS SUMP SO. TRI-STATE (SINGLE FLOAT) LEAK TEST REPORT FORMAT CATEGORY DISPENSER PAN NORMAL L15:PNL STP TRI-STATE (SINGLE FLOAT) CATEGORY STP SUMP TYPE: PUMP CONTROL OUTPUT SMARTSENS7R SETUP EVR/ISD SETUP TANK #: 3 - - - - - - - - - - - - s 1 :PS 3-4 EVk TYPE: VACUUM ASSIST LIQUID SENSOR ALMS CATEGORY VAPOR PRESSURE VACUUM ASSIST TYPE L 9:FUEL ALARM ,. HEALY VAC 2: L10:FUEL ALARM s FM 1-2 Lll :FUEL ALARM CATEGORY AIR FLOW METER NOZZLE A/L RANGE L12:FUEL ALARM s 3:FM 3-4 MAX: 1 .15 MIN: 0.95 L15:FUE ALARM CATEGORY AIR FLOW METER L 9:SEN.�Ok OUT ALARM VAPOR PROCESSOR TYPE L10:SENSOR OUT ALARM NO VAPOR PROCESSOR Lll :SENSOR OUT ALARM s 4:Ft°I 5-6 L12:SENSOR OUT ALARM CATEGORY AIR FLOW METER L15:SENSOR OUT ALARM ANALYSIS TIMES L 9:SHORT ALARM s 5:FIJI 7-8 TIME: 10:00 AM ALARM CATEGORY AIR FLOW METER Lll :SHORT ALARM DELAY MINUTES: 1 L12:SHORT ALARM L15:SHORT ALARM ACCEPT HIGH ORVR: ISD SITE ALARMS DISABLED ISD GROSS PRES FAIL ISD HOSE TABLE ISD DEGRD PRES FAIL ID FP FL HL AA RR ISD VAPOR LEAK FAIL -------•--_.-------------- ISD VP PRES FAIL O1 O1 01 02 01 UU ISD VP STATUS FAIL 02 02 02 02 01 UU ISD HOSE ALARMS 03 03 03 02 02 UU ALL:GROSS COLLECT FAIL 04 04 04 02 02 UU 05 05 05 02 03 UU ALL:DEGRD COLLECT FAIL 06 06 06 02 03 UU ALL:FLOW COLLECT FAIL 07 07 07 02 04 UU R 3:DSL 08 08 08 02 04 UU TYPE: STANDARD ISD AIRFLOW METER MAP NORMALLY CLOSED ID SERIAL NUM LABEL TANK #: 2 1 8424 FM 1-2 2 7356 FM 3-4 LIQUID SENSOR ALMS 3 8425 FM 5-6 4 8313 FM 7-8 L 3:FUEL ALARM L 9:FUEL ALARM Lll :FUEL ALARM ISD FUEL. GRADE HOSE MAP L13:FUEL ALARM 1 2 3 4 L14:FUEL ALARM FP MHH MHH MHH MHH AA L 3:SENSOR OUT ALARM - L 9:SENSOR OUT ALARM 01 201 301 901 5 U- 1 L11 :SENSOR OUT ALARM 02 202 302 902 5 U 1 {' L13:SENSOR OUT ALARM 03 203 303 903 U U 2 L14:SENSOR OUT ALARM 04 204 304 904 U U 2 L 3:SHORT ALARM 05 205 305 905 5 U 3 L 9:SHORT ALARM 06 206 306 906 5 U 3 L11 :SHORT ALARM 07 207 307 907 U U 4 L13:SHORT ALARM 08 208 308 908 U U 4 L14:SHORT ALARM R 5:OVERFILL LABEL TABLE TYPE: - ------------------- STANDARD 1 : UNASSIGNED NORMALLY OPEN 2: BLENDS TANK #: NONE 4: REGULAR 4: MID GRADE 5: PREMIUM IN-TANK ALARMS 6: GOLD 7: BRONZE ALL:OVERFILL ALARM 8: SILVER ALL:HIGH PRODUCT ALARM 9: BLEND2 ALL:MAX PRODUCT ALARM 10: BLEND4 PMC SETUP PROCESSOR CONTROL LEVEL: NONE SOFTWARE REVISION LEVEL ALARM HISTORY REPORT - VERSION 327.04 ALARM HISTORY REPORT SOFTWARE# :346327-100-E ---- IN-TANK ALARM ----- CREATED - 07.02.06. 10.28 T 2:DIESEL ---- IN-TANK ALARM ----- S-MODULE# 330160-004-a T 4:UNL 2 SYSTEM FEATURES: LOW PRODUCT ALARM PERIODIC' IN-TANK TESTS AUG 11 , 2010 9:01 AM OVERFILL ALARM ANNUAL 1N-TANK TESTS AUG 14, 2009 10:10 AM JUL 11, 2010 11 :31 PM ISD AUG 14, 2009 9:43 AM JUN 8, 2010 11 :17 PM PHO HIGH PRODUCT ALARM MAY 18, 2010 1 :56 AM AUG 14, 2009 10:08 AM LOW PRODUCT ALARM INVALID FUEL LEVEL MAR 9. 2010 7:29 PH AUG 14. 2009 10:10 AM SUDDEN LOSS ALARM PROBE OUT MAY 8, 2009 6:11 AM AUG 11. 2010 9:01 AM MAY 7, 2009 6:43 PM AUG 14, 2009 10:09 AM HIGH PRODUCT ALARM ALARM HISTORY REPORT AUG 14, 2009 9:43 AM AUG 14. 2009 10:14 AM JUL 16, 2009 5:26 AM ---- IN-TANK ALARM DELIVERY NEEDED DEC 31 , 2008 3:53 AM AUG 11 .. 2010 9:01 T 1 :UNL 1 AUG 10, 2010 5:118 AAM M PROBE OUT 2010 9:04 AM NOV 22 JUL 26. 2010 6:09 PM AUG , 22 HIGH WATER ALARM 2009 7: 16 PM NOV 23. 2009 2:47 Ire NOV 22., 2009 7:12 PM HIGH WATER WARNING OVERFILL ALARM AUG 11. 2010 9: 12 AM JUN 15, 2010 5: 11 PM JUN 4, 2010 12:30 AM DEC 15. 2009 8:34 PM DELIVERY NEEDED LOW PRODUCT ALARM MAR 19, 2010 1 :05 PM JUN 25, '2010 5:40 PM MAR 9, 2010. 3:32 PM FEB 5, 2010 3:45 PM JUN 19, 2010 11 :32 All JUN 12, 2010 10:34 PM * x * i END * x MAX PRODUCT ALARM SUDDEN LOSS ALARM DEC 31 , 2008 3:55 Af'I JUL 3. 2010 10: 12 PM APR 6, 2010 9:59 PM LOW TEMP WARNING JAN 31 , 2010 5:00 AM AUG 14, 2009 10:14 r4l HIGH PRODUCT ALARM AUG 14, 2009 10:10 AM DEC 31 , 2008 4:02 All INVALID FUEL LEVEL AUG 11 , 2010 9:03 AM ALARM HISTORY REPORT JUN 25, 2010 7:59 PM JUN 19, 2010 1 :56 Pill ---- IN-TANK ALARM ----- PROBE OUT T 3:PNL >f * END AUG 11 , 2010 9:02 AM NOV 23, 2009 2:51 PM HIGH PRODUCT ALARM NOV 23, 2009 2:40 PM AUG 14, 2009 10:06 AM HIGH WATER WARNING PROBE OUT NOV 23, 2009 2:47 1-r1 AUG 11 , 2010 9:00 AM AUG 14, 2009 10:07 All AUG 14, 2009 9:44 AM DELIVERY NEEDED JUN 25, 2010 4:00 PH JUN 19, 2010 8: 18 All DELIVERY NEEDED JUN 12, 2010 6:18 PM APR 6, 2010 3:31 PM MAR 19, 2010 10:20 AM JAN 29, 2010 10:30 PM LOW TEMP WARNING NOV 23, 2009 2:52 PM AUG 14. 2009 10:12 AM x * x * x END x X * X x END --. IN-TANK ALARM ----- ALARM HISTORY REPORT ALARM HISTORY REPORT T 4:UNL 2 HIGH WATER WARNING ----- SENSOR ALARM ----- ----- SENSOR ALARM ----- AUG 11 , 2010 9:12 AM L 3:DSL STP L 6:PNL ANN STP SUMP, ANNULAR SPACE. FUEL ALARM SENSOR OUT ALARM JUL 1, 2010 2:52 AM AUG 14, 2009 10:18 AM FUEL ALARM FUEL ALARM JUN 8, 2010 9:02 PM AUG 14, 2009 10:03 AM FUEL ALARM ALARM HISTORY REPORT MAY 18, 2010 4:09 AM ----- SENSOR ALARM ----= L I :UNL" 1 STP STP SUMP FUEL ALARM JUL 23, 2010 8:26 PM * END * * x FUEL ALARM JUL 5, 2010 6:18 PM SENSOR OUT ALARM * * * * END AUG 14, 2009 10: 18 AM ALARM HISTORY REPORT ----- SENSOR ALARM ----- * * * * END * * * * ;� ALARM HISTORY REPORT L 7:UNL 2 STP STP SUMP -- SENSOR ALARM ----- FUEL ARM M 2:27 AM L 4:DSL ANN JUL ANNULAR SPACE SENSOR OUT ALARM FUEL ALARM AUG 14, 2009 10: 18 AM JUN 16, 2010 7:32 AM FUEL ALARM FUEL ALARM AUG 14, 2009 10:03 AM MAY 26, 2010 11 :53 AM ALARM HISTORY REPORT ----- SENSOR ALARM ----- L 2:UNL 1 ANN ANNULAR SPACE SENSOR OUT ALARM AUG 14, 2009 10:18 AM FUEL ALARM * * * * * END END * * * * * * * S * * * * AUG 141 2009 10:04 AM * * * * END * * ALARM HISTORY REPORT ALARM. HISTORY REPORT ----- SENSOR ALARM ----- ----- SENSOR ALARM ----- L 5: L B:UNL 2 ANN OTHER SENSORS ANNULAR SPACE SENSOR OUT ALARM AUG 14, 2009 10:18 AM FUEL ALARM AUG 14, 2009 10:04 AM * END * * x x x END x x x x x F M H I STORY REPORT SENSOk ALARM ----- ALARM HISTORY REPORT ALARM HISTORY REPORT DISP 1-2 -- SENSOR ALARM ----- ----- SENSOR ALARM ENSER PAN I - L14:TRANS SUMP SO. SENSOR OUT ALARM L11 :DISE 5-6 AUG 14. 2009 10:18 AM DISPENSER PAN DISPENSER PAN SENSOR OUT ALARM FUEL ALARM FUEL ALARM AUG 14. 2009 10:18 AM SEP 9, 2009 1 :21 PM AUG 14.. 2009 10:00 AM FUEL ALARM SENOR OUT ALARM AUG 14. 2009 10:00 AM AUG 27, 2009 11 :46 AM FUEL ALARM AUG 27, 2009 11 :42 AM END -- * * * END * * END ALARM HISTORY REPORT -- SENSOR ALARM ----- ALARM HISTORY REPORT L 9:DISP 1-2 ----- SENSOR ALARM ----- DISPENSER PAN L12:DISP 7-8 ALARM HISTORY REPORT SENSOR OUT ALARM DISPENSER PAN AUG 14. 2009 10:18 AM SENSOR OUT ALARM ----- SENSOR ALARM ----- FUEL ALARM AUG 14. 2009 10:18 AM L15:PNL STP AUG 14, 2009 10:00 AM STP SUMP FUEL ALARM FUEL ALARM AUG 14. 2009 10:01 AM JUN 15. 2010 6:13 AM FUEL ALARM APR 22. 2010 1 :54 AM FUEL ALARM APR 21, 2010 5:39 PM * * * * END * * x * * * x END * MEND * * ALARM HISTORY REPORT ----- SENSOR ALARM ----- ALARM HISTORY REPORT L10:DISP 3-4 ----- SENSOR ALARM ----- DISPENSER PAN L13:TRANS SUMP NO. SENSOR OUT ALARM DISPENSER PAN AUG 14, 2009 10:18 AM FUEL ALARM FUEL ALARM SEP 9, 2009 1 :24 PM FASTRIP 347 2698 OSWELL ST. AUG 14, 2009 9:59 AM SENSOR OUT ALARM BAKERSFIELD,CA93306 AUG 28, 2009 8:04 AM 661-872-8781 SENSOR OUT ALARM AUG 11, 2010 9:13 AM AUG 28, 2009 8:01 AM - SYSTEM-STATUS REPORT- _ T 4:HIGH WATER WARNING * END END * x ----- SENSOR ALARM ----- L15:PNL STP ----- SENSOR-ALARM ----- ---- IN-TANK ALARM ----- STP SUMP L11 :DISP 5-6 - T 3:PNL FUEL ALARM DISPENSER PAN HIGH PRODUCT ALARM AUG 11 . 2010 9:14 AM FUEL ALARM AUG 11, 2010 9:22 AM AUG 11, 2010 9:19 AM ----- SENSOR ALARM ----- ---- IN-TANK ALARM ----- L 3:DSL STP ----- SENSOR ALARM ----- T 3:PNL STP SUMP L12:DISP 7-8 PROBE OUT FUEL ALARM DISPENSER PAN AUG 11, 2010 9:23 AM AUG 11, 2010 9:15 AM FUEL ALARM AUG 11 . 2010 9:19 AM ---- IN-TANK ALARM ----- ----- SENSOR ALARM ----- T 3:PNL L 1 :UNL 1 STP ----- SENSOR ALARM ----- LOW TEMP WARNING STP SUMP L 6:PNL ANN AUG 11. 2010 9:23 AM FUEL ALARM ANNULAR SPACE AUG 11. 2010 9: 15 AM FUEL ALARM AUG 11 . 2010 9:20 AM ----- SENSOR ALARM ----- L13:TRANS SUMP NO. ----- SENSOR ALARM ----- DISPENSER PAN L 7:UNL 2 STP ----- SENSOR ALARM ----- FUEL ALARM STP SUMP L 4:DSL ANN AUG 11 , 2010 9:28 AM FUEL ALARM ANNULAR SPACE AUG 11, 2010 9: 16 AM FUEL ALARM AUG 111 2010 9:21 AM ----- SENSOR ALARM ----- L14:TRANS SUMP SO- ----- SENSOR ALARM, ----- DISPENSER PAN L10:DISP 3-4 ----- SENSOR ALARM ----- FUEL ALARM DISPENSER PAN L 2:UNL 1 ANN AUG 11, 2010 9:30 AM FUEL ALARM ANNULAR SPACE AUG 11, 2010 9:17 AM FUEL ALARM AUG 11 . 2010 9:21 AM Il ---- IN-TANK ALARM ----- -- SENSOR ALARM -- _ T 2:DIESEL HIGH PRODUCT ALARM L 9:DISP 1-2 ----- SENSOR ALARM ----- AUG 11. 2010 9:31 AM DISPENSER PAN L 8:UNL 2 ANN FUEL ALARM ANNULAR SPACE AUG 11 , 2010 9:18 AM FUEL ALARM AUG 11, 2010 9:22 AM ---- IN-TANK ALARM ----- T 2:DIESEL PROBE OUT AUG 11. 2010 '9:32 AM 1 ---- IN-TANK ALARM ----- -- -- --- - — -- --- -— T 1 :UNL ! ---- IN-TANK ALARM ----- T OBE O 2 HIGH PRODUCT ALARM AUG 11 , 2010 9:33 AM PROBE OUT -- SENSOR ALARM ----- j AUG 11 , 2010 9:35 AM L12:DISP 7-B DISPENSER PAN SENSOR OUT ALARM AUG 11, 2010 9:36 AM -- IN-TANK ALARM ----- FASTRIP 347 T 1 :UNL 1 2698 OSWELL ST. PROBE OUT BAKERSFIELD.CA93306 AUG 11, 2010 9:33 AM 661-872-8781 ----- SENSOR ALARM ----- AUG 11, 2010 9:35 AM L14:TRANS SUMP 80. DISPENSER PAN SENSOR OUT ALARM AUG 11. 2010 9:36 AM SYSTEM STATUS REPORT - T 4:PROBE OUT ---- IN-TANK ALARM ----- T 1 :UNL 1 LOW TEMP WARNING AUG 11 . 2010 9;34 AM ----- SENSOR ALARM ----- L15:PNL STP STP SUMP SENSOR OUT ALARM AUG 11, 2010 9:36 AM ----- SENSOR ALARM ----- L 9:DISP 1-2 T 2:DIESEL DISPENSER PAN INVENTORY INCREASE SENSOR OUT ALARM flUG 11. 2010 9:36 AM INCREASE START AUG 11, 2010 9:31 AM FASTRIP 347 VOLUME = 6579 GALS 2698 OSWELL ST. HEIGHT = 51 .64 INCHES BAKERSFIELD,CA93306 WATER = 0.96 INCHES 661-872-8781 TEMP o 93.2 DEC F ,{ -- SENSOR ALARM ----- AUG 11 , 2010 9:36 AM INCREASE END L10:DISP 3-4 AUG 11, 2010 9:34 AM DISPENSER PAN VOLUME = 11145 GALS SENSOR OUT ALARM - - 84.11 INCHES SYSTEM STATUS REPORT HEIGHT AUG 11, 2010 . 9:36 AM ' WATER a 0.75. INCHES L10:SENSOR OUT ALARM TEMP 92.8 DEG F L11 :SENS6R OUT ALARM GROSS INCREASE- 4566 L12:SENSOR OUT ALARM TC NET INCREASE- 4499 L13:SENSOR OUT ALARM - SENSOR ALARM ----- L14:SENSOR OUT ALARM L13:TRANS SUMP NO. L15:SENSOR OUT ALARM DISPENSER PAN SENSOR OUT ALARM AUG 11, 2010 9:36 AM ---- IN-TANK ALARM ----- T 4:UNL 2 HIGH PRODUCT ALARM AUG 11. 2010 9:34 AM ----- SENSOR ALARM ----- L11 :DISP 5-6 DISPENSER PAN SENSOR OUT ALARM AUG 11. 2010 9:36 AM T 1 :UNL 1 INVENTORY INCREASE INCREASE START AUG 11. 2010 9:32 AM VOLUME = 7878 GALS HEIGHT - 59.93 INCHES WATER - 1 .43 INCHES TEMP - 84.3 DEG F INCREASE END AUG 11, 2010 9:36 AM VOLUME = 9439 GALS HEIGHT - 70.46 INCHES WATER = 0.00 INCHES TEMP = 85:4 DEG F GROSS INCREASE- 1561 TC NET INCREASE- 1527 T 4:UNL 2 INVENTORY INCREASE INCREASE START AUG 11, 2010 9:34 AM VOLUME - 5499 GALS HEIGHT = 44.85 INCHES WATER - 0.00 INCHES TEMP = 78.0 DEG F INCREASE END AUG 11, 2010 9:38 AM VOLUME - 9666 GALS HEIGHT - 72.08 INCHES WATER . 1 .02 INCHES TEMP = 74.2 DEG F GROSS INCREASE- 4167 TC NET INCREASE- 4140 SWRCB,January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests(if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: 4347 Fastrip#26 Date of Testing: 8/11/2010 Facility Address: 2698 Oswell Street,Bakersfield,CA 93306 Facility Contact: Omero Garcia I Phone: 661-393-7000 Date Local Agency Was Notified of Testing: 7/23/2010 Name of Local Agency Inspector(f present during testing): Ernie Medina 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Bryan A Self Credentials: X CSLB Contractor X ICC Service Tech. ❑SWRCB Tank Tester ❑Other(Spec) License Number(s): CSLB#804904 ICC 98022804-UT 3. SPILL BUCKET TESTING INFORMATION Test Method Used: x Hydrostatic ❑Vacuum ❑Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket(By Tank 1 Regular 1 2 Regular 2 3 Super 4 Diesel Number, Stored Product, etc. Bucket Installation Type: ❑ Direct Bury ❑ Direct Bury ❑Direct Bury ❑Direct Bury x Contained in Sump x Contained in Sump x Contained in Sump x Contained in Sum Bucket Diameter: 12.00" 12.00" 12.00" 12.00" Bucket Depth: 14.00" 13.75" 14.00" 14.00" Wait time between applying 5 min. 5 min. 5 min. 5 min. vacuum/water and start of test: Test Start Time(Tj): 9:00am 9:00am 9:00am 9:00am Initial Reading(Rj): 10.75" 11.50" 11.00" 10.50" Test End Time(TF): 10:00am 10:00am 10:00am I0:00am Final Reading(RF): 10.75" 11.50" 11.00" 10.50" Test Duration(TF—Ti): 1 hour 1 hour I hour 1 hour Change in Reading(RF-R,): 0.00" 0.00" 0.00" 0.00" Pass/Fail Threshold or 0.0625" 0.0625" 0.0625" 0.0625" Criteria: Test Result: X Pass ❑Fail X Pass ❑Fail X Pass ❑Fail X Pass ❑Fail Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true,accurate,and in full compliance with legal requirements. Technician's Signature: Date: 8/11/2010 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent.