Loading...
HomeMy WebLinkAboutFMC 2011 RESULTS IIIIIIIIIIIIIIIIIIII 41 MONITORING SYSTEM CERTIFICATION IE For Use By All Jurisdictions Within the State of California Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring system control anel by the technician who performs the work. A Copy of this form must be provided to the tank system owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name: PENSKE BAKERSFIELD Bldg.No: Site Address: 2929 E. BRUNDAGE LANE City: BAKERSFIELD Zip: Facility Contact Person: Phone: Fax: Make/Model of Monitoring System: VEEDER ROOT SIMPLICITY Date of Testing/Servicing: 2/10/2011 B. Inventory of Equipment Test/Certified Check the appropriate boxes to indicatespecific equipment inspected/serviced: Tank ID: DIESEL NORTH Tank ED: DIESEL SOUTH hi-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: Annular Space or Vault Sensor. Model: 301 T Annular Space or Vault Sensor. Model: 301 Piping Sump/Trench Sensor(s). Model: 352 Piping Sump/Trench Sensor(s). Model: 352 Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. Model: T Mechanical Line Leak Detector. Model: RED JACKET Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: Tank Overfill/High Level Sensor. Model: OPW Flaper Tank Overfill/High Level Sensor. Model: OPW Flaper X Other(specify equipment type and model in Section E on Page 2) X Other(specify equipment type and model in Section E on Page 2) Tank ID• Tank ED: In-Tank Gauging Probe. Model: hi-Tank Gauging Probe. Model: Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: H Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: Tank Overfill/High Level Sensor. Model: Tank Overfill/High Level Sensor. Model: E]Other(specify equipment type and model in Section E on Page 2) Other(specify equipment type and model in Section E on Page 2) Dispenser ED: MASTER 1-2 Dispenser ID: SATELITE 1 Dispenser Containment Sensor(s). Model: 352 Dispenser Containment Sensor(s). Model: 322 Shear Valve(s). Shear Valve(s). Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). oft Dispenser ID: SATELITE 2 Dispenser ID: Dispenser Containment Sensor(s). Model: 322 Dispenser Containment Sensor(s). Model: Shear Valve(s). Shear Valve(s). Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). Dispenser ID: DI Buser ID: Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s), Mode Shear Valve(s). Shear Valve(s). Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). aw •If the facility contains more thanks or dispensers,copy this form Include information for every tank and dispenser at the facility. C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report;(check all that apply): _X_System set-up X_Alarm History report Technician Name(print): Gerardo Zuniga Signature: Certification No.: B34891 License No 745065 A,B-Haz Testing Company Name: Tank Specialists of California Ph el o.: (g09)273-0900 Facility Address: 560 Birch Street, Unit#3 Lake Elsinore, Ca Date of T,esfing/Servicing: 2/10/2011 Monitoring System Certification Page 1 of 3 03/01 PENSKE BAKERSFIELD Mont Cert 2-10-2011.)ds I IIIII�VIII III IIII 42 IE D. Results of Testing/Servicing PENSKE BAKERSFIELD Software Version Installed: 123.01 2/10/2011 Complete the following checklist: X Yes No* Is the audible alarm operational? X Yes No* Is the visual alarm operational? ]Yes No* Were all sensors visually inspected,functionally tested,and confirmed operational? X Yes No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? LX Yes No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? N/A X Yes No* Fore pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring system N/A detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate positive shut-down?(Check all that apply)_X_Sump/Trench Sensors _X_Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? X Yes No. Yes No* For Tank systems that utilize the monitoring system as the primary tank overfill warning device(ie.,no mechanical WN/A overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly?If so,at what percent of tank capacity does the alarm trigger? % Yes X No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E,below. Yes X No Was liquid found inside any secondary containment systems designed as dry systems?(Check all that apply) Product; _Water. If yes,describe causes in Section E,below. X Yes No* Was monitoring system set-up reviewed to ensure proper settings?Attached set up reports,if applicable. X Yes No* Is all monitoring equipment operational per manufacturer's specifications? * In Section E below,describe how and when these deficiencies were or will be corrected: E.Comments: There is also oil line low point sensor 420 Monitoring System Certification Page 2 of 3 03/01 PENSKE BAKERSFIELD Mont Cart 2-102011.x1s F.'fn=Tank Gauging/ SIR Equipment: eX Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. Complete the following checklist: Ex Yes E]No* Has all input wiring been inspected for proper entry and termination,including testing for ground faults? ❑x Yes E]No* Were all tank gauging probes visually inspected for damage and residue buildup? aYes E]No* Was accuracy of system product level reading tested? QYes []No* Was accuracy of system water level readings tested? lEx Yes nNo* Were all probes reinstalled properly? Eyes No* Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H,Below,describe how and when these deficiencies were or will be corrected. G.Line Leak Detectors(LLD): Check this box if LLDs are not installed. Complete the following checklist: ❑X Yes No* For equipment start-up or annual equipment certification,was a leak simulated to verify LLD performance?(Check N/A all that apply) Simulated Leak rate: X_3 g.p.h. 0.1 g.p.h. 0.2 g.p.h. X Yes No Were all LLDs confirmed operational and accurate within regulatory requirement? X Yes No Was the testing apparatus properly calibrated? X Yes No* For Mechanical LLDs,does the LLD restrict product flow if it detects a leak? N/A Yes No* For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? X N/A Yes No* For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system is disabled or EX N/A disconnected? Yes No* For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions or X N/A fails a test? V Yes No* For electronic LLDs,have all accessible wiring connections been visually inspected? N/A s [-]No* Were all items on the equipment manufacturer's maintenance checklist completed? * In Section H below,describe.how and when these deficiencies were or will be corrected: H.Comments: Monitoring System Certiflcation Page 3 of 3 03/01 PENSKE BAKERSFIELD Mont Cent 2-10-2011.xls Facility Name: PENSKE BAKERSFIELD Test Date: 2/10/2011 1. SPILL/OVERFILL CONTAINMENT BOXES Facility is Not Equipped With Spill/Overfill Containment Boxes Spill/Overfill Containment Boxes are Present,but were Not Tested Test Method Developed By: Spill Bucket Manufacturer ❑ Industry Standard E] Professional Engineer Other(Specify) Test Method Used: ❑ Pressure Vacuum 1XI Hydrostatic E] Other(Specify) Test Equipment Used: INCON ui ment Resolution: DSL.FILL IS.DSL FILL Sill Box# Spill Box# Spill Box# Bucket Diameter: 12 IN. 12 IN. Bucket Depth: 13 IN. 12 1/2 IN. Wait time between applying pressure/vacuum/water and starting test: Test Start Time: 10:54 AM AM Initial Reading(R): 4.5531 IN. IN. Test End Time: 11:09 AM AM Final Reading(RF): 4.5525 IN. IN. Test Duration: 15 MIN. 15 MIN. Change in Reading(RF-R): 0.0006 IN. IN. Pass/FaiI Threshold or Criteria: 0.002 IN. 0.002 IN. Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) SOUTH FILL SPILL BUCKET FAILED DUE TO SPILL BUCKET NEED TO REPLACE DREICT BURY OPW SPILL UST Monitoring Site Plan Date: 2/10/2011 Site Location: PENSKE BAKERSFIELD 2929 E. BRUNDAGE BAKERSFIELD ,CA 93307 SHOP ESO VEEDER ROOT SIMPLICIT SATELITE DISPENSER#2 OIL LINE 322 SENSOR 420 SENSOR MASTER DISPENSER# 1-2 352 SENSOR SATELITE DISPENSER# 1 322 SENSOR ANNULAR SPACE PIPING SUMP 301 SENSOR FILL SPILL BUCKE 352 SENSOR NORTH DIESEL TANK SIPHONE TANK OPW DROP TUIAES WITH FLAPERS RED JACKET LINE LEAK DETECTOR SOUTH DIESEL TANK PIPING SUMP 301 SENSOR 352 SENSOR FILL SPILL BUCKET I ANNULAR SPACE INSTRUCTIONS If you already have a diagram that shows all required information,you may include it,rather than this page,with your Monitoring System Certification. On your site plan,show the general layout of tanks and piping.Clearly identify locations of the following equipment,if installed; monitoring system control panels;snesors monitoring tank annular spaces,sumps,dispenser pans,spill containers,or other secondary containment areas;mechanical or electronic line leak detectors;and in-tank liquid level probes(if used for leak detection). In the space provided,note the date this Site Plan was prepared. Tank Specialists of California (888) 606-TANK (#745065 A,B-HAZ) Page 4 109755 ROLLING 140 SYSTEM SETUP RS-232 END OF MESSAGE 2929 E BRUNDAGE — — — — — — — — — — — — DISABLED BAKERSFIELD. CA FEB 10, 2011 10:08 AM COMMUNICATIONS SETUP — — 80448302105001 — — — — FEB 10, 2011 10:08 AM SYSTEM UNITS PORT SETTINGS: U.S. 1 (FXMOD) SYSTEM LANGUAGE COMM BOARD SYSTEM STATUS REPORT ENGLISH BAUD RATE 2400 ITY ODD SYSTEM DATE/TIME FORMAT PAR ALL FUNCTIONS NORMAL MON DD YYYY HH:MM:SS xM STOP BIT 1 STOP DATA LENGTH: 7 DATA 109755 ROLLING 140 RS-232 SECURITY 2929 E BRUNDAGE CODE : DISABLETONE BAKERSFIELD CA DIAL TYPE 1 RING 80448302105001 ANSWER ON SHIFT TIME 1 5:45 AM ' MODEM SETUP STRING : SHIFT TIME 2 DISABLED DIAL TONE INTERVAL: 32 SHIFT TIME 3 DISABLED i 2 (S—SAT ) 109755 ROLLING 140 SHIFT TIME 4 DISABLED ! COMM BOARD 9600 2929 E BRUNDAGE BAUD RATE NONE BAKERSFIELD CA TANK PER TST NEEDED WRN PARITY I STOP 80448302105001 DISABLED STOP HIT TANK ANN TST NEEDED WRN DATA LENGTH:-8 DATA FEB 10, 2011 10:08 AM DISABLED I RS-232 SECURITY CODE : DISABLED LINE RE—ENABLE METHOD DTR NORMAL STATE: HIGH PASS LINE TEST I SYSTEM— —STATUS REPORT 1 RECEIVER SETUP: — — — — — — — — LINE PER TST NEEDED WRN ALL FUNCTIONS NORMAL DISABLED LINE ANN TST NEEDED WRN INVENTORY REPORT DISABLED D 8:VEEDER ROOT (FMS) PRINT TC VOLUMES RCVR TYPE: COMPUTER T 1 :DIESEL 1 SOUTH ENABLED PORT NO. 2 VOLUME = 7161 GALS RETRY NO: 5 ULLAGE = 4266 GALS TEMP COMPENSATION RETRY DELAY: 5 90 ULLAGE= 3123 GALS VALUE (DEG F ) : 60.0 's CONFIRMATION REPORT: OFF TC VOLUME = 7137 GALS STICK HEIGHT OFFSET HEIGHT = 52.70 INCHES DISABLED WATER VOL = 0 GALS WATER = 0.00 INCHES H—PROTOCOL DATA FORMAT TEMP = 67.1 DEG F HEIGHT DAYLIGHT SAVING TIME ENABLED i T 2:DIESEL 2 NORTH START DATE ! VOLUME = 6636 GALS MAR WEEK 3 SUN ULLAGE = 4791 GALS START TIME 90% ULLAGE= 3648 GALS 2:00 AM TC VOLUME = 6615 GALS END DATE AUTO DIAL TIME SETUP: HEIGHT = 49.51 INCHES NOV WEEK 1 SUN WATER VOL = 0 GALS END TIME WATER = 0.00 INCHES 2:00 AM D 8:VEEDER ROOT (FMS) TEMP = 66.9 DEG F DIAL WEEKLY RE—DIRECT LOCAL PRINTOUT WED 3:15 AM DISABLED DIAL TIME RECEIVER REPORTS: EURO PROTOCOL PREFIX 1 1 :DIESEL 1 SOUTH S PRODUCT CODE 1 THERMAL COEFF : .000450 TANK DIAMETER 90.00 TI'y RS-232 FND OF MESSAGE DISABLED' ' ALARM T 2:DIESEL 2 NORTH AUTO DIAL ALAR _ _ _ _ _ _ PRODUCT CODE 2 FLOAT SIZE: 4.0 IN. THERMAL COEFF : .000450 D 8:VEEDER ROOT (FMS) TANK DIAMETER 90.00 WATER WARNING 2.0 TANK PROFILE 4 PTS IN-TANK ALARMS HIGH WATER LIMIT: 3.0 FULL VOL 11427 ALL:LEAK ALARM 67.5 INCH VOL 9435 ALL:HIGH WATER ALARM MAX OR LABEL VOL: 11594 45.0 INCH VOL 5888 ALL:OVERFILL ALARM OVERFILL LIMIT 891/0 22.5 INCH VOL 2289 ALL:LOW PRODUCT ALARM 10318 HIGH PRODUCT 94% ALL:SUDDEN' LOSS ALARM 1094% FLOAT SIZE; ALL:HIGH PRODUCT ALARM DELIVERY LIMIT 12% 4.0 IN. ALL: INVALID FUEL LEVEL 1391 WATER WARNING ALL:PROHE OUT 2.0 ALL:HIGH WATER WARNING LOW PRODUCT 1000 HIGH WATER LIMIT: 2.5 ALL:DELIVEOD NEEDED LEAK ALARM LIMIT: 25 MAX OR LABEL VOL: 11594 ALL:MflX PRODUCT ALARM SUDDEN LOSS LIMIT: 25 OVERFILL LIMIT ALL:GROSS TEST FAIL 89% TA ALL:PERIODIC TEST FAIL TANK TILT 0.70 10318 ALL:ANNUAL TEST FAIL PROBE OFFSET 0.70 HIGH PRODUCT 94% ALL:PER TST NEEDED WRN 10898 ALL:PER TST NEEDED ALM SIPHON MANIFOLDED TANKS DELIVERY LIMIT 12% ALL:NO CSLD IDLE TIME 1391 ALL:CSLD INCR RATE WARN T#: NONE ALL:ACCU_CHART CAL WARN LINE OANIFOLDED TANKS LOW PRODUCT 1000 ALL:RECON WARNING T#: NONE LEAK ALARM LIMIT: 25 SUDDEN LOSS LIMIT: 25 RLL:RECON ALARM TANK TILT ALL:LOW TEMP WARNING LEAK MIN PERIODIC: 25% 1 .25 PROBE OFFSET ALL:GROSS FAIL LINE TNK 2898 1 .25 LIQUID SENSOR ALMS LEAK MIN ANNUAL 25o SIPHON MANIFOLDED TANKS ALL:FUEL ALARM 2898 T#: NONE ALL:SENSOR OUT ALARM LINE MANIFOLDED TANKS ALL:SHORT ALARM T#: NONE ALL:WATER ALARM PERIODIC TEST TYPE ALL:WATER OUT ALARM STANDARD ALL:HIGH LIQUID ALARM LEAK MIN PERIODIC: 25% ALL:LOW LIQUID ALARM ANNUAL TEST FAIL � 2898 ALL:LIQUID WARNING ALARM DISABLED LEAK MIN ANNUAL RECEIVER ALARMS PERIODIC TEST FAIL 2898 SERVICE REPORT WARN ALARM DISABLED ALARM CLEAR WARNING GROSS TEST FAIL PERIODIC TEST TYPE ALARM DISABLED STANDARD ANN TEST AVERAGING: OFF ANNUAL TEST FAIL PER TEST AVERAGING: OFF ALARM DISABLED TANK TEST NOTIFY: OFF PERIODIC TEST FAIL TNK TST SIPHON BREAK:OFF ALARM DISABLED GROSS TEST FAIL DELIVERY DELAY 5 MIN ALARM DISABLED IN-TANK SETUP PUMP THRESHOLD : 10.00% - _ - _ - - - - _ ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF T 1 :DIESEL 1 SOUTH TANK TEST NOTIFY: OFF PRODUCT CODE 1 THERMAL COEFF : .000450 TNK TST SIPHON BREAK:OFF TANK DIAMETER 90.00 TANK PROFILE 4 PTS DELIVERY DELAY FULL VOL 11427 PUMP THRESHOLD 5 MITI LD 67.5 INCH VOL 9435 : 10.00% 45.0 INCH VOL 5888 22.5 INCH VOL 2289 TEST WEEKLY : ALL TANK- OUTPUT RELAY SETUP SAT - - - - - - - - - - - -- ----- SENSOR ALARM ----- START TIME : 10:00 PM L S:ANNULAR 1 TANK TEST RATE :0.20 GAL/HR R 1 :ALARM ANNULAR SPACE DURATION 2 HOURS TYPE: LOW LIQUID ALARM STANDARD FEB 10, 2011 10:05 AM TST EARLY STOP:DISABLED NORMALLY CLOSED LEAK TEST REPORT FORMAT ENHANCED IN-TANK ALARMS ALL:HIGH WATER ALARM T 1 :LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:GROSS TEST FAIL LIQUID SENSOR ALMS ----- SENSOR ALARM ----- L 1 :FUEL ALARM L 6:STP SUMP 1 TANK L 3:FUEL ALARM STP SUMP L 4:FUEL ALARM FUEL ALARM L 5:FUEL ALARM FEB 10, 2011 10: 10 AM L 6:FUEL ALARM LIQUID SENSOR SETUP L 7:FUEL ALARM - - - - - - - - - - - - L 8:FUEL ALARM ALL:SENSOR OUT ALARM L 1 :SATELITE DISP PAN ALL:SHORT ALARM DUAL FLT. HIGH VAPOR ALL:LOW LIQUID ALARM CATEGORY : DISPENSER PAP! L 8:LIQUID WARNING ----- SENSOR ALARM ----- L 2:0IL LINE L 7:ANNULAR 2 TANK TRI-STATE (SINGLE FLOAT) ANNULAR SPACE CATEGORY : PIPING SUMP LOW LIQUID ALARM FEB 10, 2011 10:10 AM L 3:PIPING MID PAN DUAL FLT. HIGH VAPOR CATEGORY : DISPENSER FAN RECONCILIATION SETUP L 4:SATELITE DISP PAN S DUAL FLT. HIGH VAPOR AUTOMATIC DAILY CLOSING CATEGORY DISPENSER PAN TIME: 2:00 AM ----- SENSOR ALARM -- --- L 7:ANNULAR 2 TANK PERIODIC RECONCILIATION ANNULAR SPACE MODE: MONTHLY LOW LIQUID ALARM L 5:ANNULAR 1 TANK FEB 10.2011-1'9:11 All DUAL FLOAT HYDROSTATIC TEMP COMPENSATION CATEGORY : ANNULAR SPACE STANDARD BUS SLOT FUEL METER TANK L 6:STP SUMP 1 TANK TANK MAP EMPTY DUAL FLT. HIGH VAPOR CATEGORY : STP SUMP ----- SENSOR ALARM ----- L 7:ANNULAR 2 TANK L B:STP SUMP 2 TANK DUAL FLOAT HYDROSTATIC STP SUMP CATEGORY : ANNULAR SPACE LIQUID WARNING FEB10r 2011 10:11 AM L 8:STP SUMP 2 TANK ----- SENSOR ALARM ----- L 3:PIPING MID PAN ----- SENSOR ALARM ----- DISPENS.ER -PAN L 8:STP SUMP 2 TANK FUEL ALARM STP SUMP FEB 10, 2011 10:13 AM SENSOR OUT ALARM FEB 10, 2011 10: 16 AM ALARM HISTORY REPORT -- SYSTEM ALARM -- PAPER OUT --- JAN 19, 20 PRINTER 5:34 FM IVTER ERROR JAN 19, 2011 5:34 PM BATTERY IS OFF JAN 1 , 1996 8:00 AM ----- SENSOR ALARM ----- L 1 :SATELITE DISP PAN DISPENSER PAN SENSOR OUT ALARM FEB 10, 2011 10: 16 All * * END * n ----- SENSOR ALARM ----- L 2:011- LINE PIPING SUMP SENSOR OUT ALARM SENSOR ALARM ----- FEB 10, 2011 10:16 All L 1 :SATELITE DISP FAN DISPENSER PAN ALARM HISTORY REPORT FUEL ALARM FEB 10, 2011 10: 14 AM IN-TANY•. ALARM - T 1 :DIESEL 1 SOUTH SETUP DATA WARNING -- SENSOR ALARM ----- AUG 11 , 2009 11 :26 AM L P PAN MID PAN DISPENSER HIGH WATER ALARM ENS OCT 2 SENSOR OUT ALARM OC 2009 10:44 AM T 15, FEB 10, 2011 10: 16 AM 2004 10:52 All ----- SENSOR ALARM ----- OCT 2, 2003 11 :18 AM L 2:0IL LINE PIPING SUMP OVERFILL ALARM FUEL ALARM JUN 18, 2010 12: 19 PM FEB 10, 2011 10: 15 AM FEB 10, 2010 10:49 All JAN 29, 2010 4:40 PM LOW PRODUCT ALARM AUG 11 , 2009 11 :28 AM -- SENSOR ALARM ----- JUN 13, 2009 10:37 AM L 4:SATEL.ITE DISP PAN S JUL 22, 2008 5:47 PM --_-- DISPENSER PAN HIGH PRODUCT SENSOR OUT ALARM OCT 28, '.)00 ALARM AM FEB 10, 2011 10: 16 AM FEB 22, X9 10:40 -- SENSOR ALARM DEC 26, `007 8:50 AM L 5:ANNULAR 1 TANK 2006 ANNULAR SPACE 8:19 AM ALID SENSOR OUT ALARM INVALID FUEL LEVEL FEB 10, 2011 10:16 AM OCT 2 15, 2004 10:40 AM 2003 11 : 15 All ----- SENSOR ALARM ----- L 6:STP SUMP 1 TANK STP SUMP SENSOR OUT ALARM SENSOR ALARM ----- FEB 10, 2011 10: 16 AM ----- L 7:ANNULAR 2 TANK ANNULAR SPACE SENSOR OUT ALARM FEB 10, 2011 10:16 AM INVALID FUEL LEVEL ALARM H 1 STORY xh1'QX 1 PROBE OUT OCT 9, 2009 9:31 AM SENSOR ALARM ----- DEC ' 9, 2009 4:42 PM JUN 13, 2009 9:22 AM L 2:0IL LINE OCT 28, 2009 11 : 16 AM JUN 2, 2009 9:20 AM PIPING SUMP OCT 28, 2009 11 :09 AM PROBE OUT SENSOR OUT ALARM HIGH WATER WARNING DEC 9, 2009 4:38 PM FEB 10, 2011 10: 16 AM OCT 28, 2009 10:44 AM OCT 28, 2009 10:28 AM FUEL ALARM OCT 15, 2004 10:52 AM OCT 9, 2009 9:49 AM FEB 10, 2011 10: 15 AM FEB 2, 2004 10:22 AM HIGH WATER WARNING FUEL ALARM DEC 9, 2009 4:46 PM JAN 13, 2011 11 :36 PM DELIVERY NEEDED OCT 9, 2009 9:48 AM AUG 11 , 2009 11 :28 AM OCT 9, 2009 7:38 AM JUN 12, 2009 4:39 PM JUN 2, 2009 7:51 AM DELIVERY NEEDED MAX PRODUCT ALARM JUN 12, 2009 2:39 PM OCT 28, 2009 11 :06 AM JUN 1 , 2009 2:17 PM OCT 28, 2009 10:40 AM MAR 10, 2009 5:04 PM OCT 15, 2004 10:29 AM MAX PRODUCT ALARM OCT 9, 2009 9:39 AM * € END LOW TEMP WARNING OCT 15, 2004 10:28 AM OCT 15, 2004 10:29 All OCT 2, 2003 11 :13 AM LOW TEMP WARNING OCT 28, 2009 10:39 AM OCT 8, 2009 3:05 PM OCT 15, 2004 11 :02 AM * END ALARM HISTORY REPORT ----- SENSOR ALARM ----- L 3:PIPING MID PAN DISPENSER PAN SENSOR OUT ALARM * * END FEB 10, 2011 10: 16 AM FUEL ALARM FEB 10, 2011 10: 13 AM SENSOR OUT ALARM DEC 9, 2010 10:04 All ALARM HISTORY REPORT ---- IN-TANK ALARM ----- T 2:DIESEL 2 NORTH HIGH WATER ALARM ALARM HISTORY REPORT OCT 9, 2009 9:48 AM OCT 15, 2004 10:52 AM ----- SENSOR ALARM ----- OCT 2, 2003 11 : 18 AM L 1 :SATELITE DISP PAN DISPENSER PAN * END x OVERFILL ALARM SENSOR OUT ALARM FEB 16, 2010 12:31 PM FEB 10, 2011 10: 16 AM OCT 9, 2009 9:39 All JUL 2, 2009 6:42 AM FUEL ALARM FEB 10, 2011 10:14 AM LOW PRODUCT ALARM JUN 12, 2009 4:48 PM SENSOR OUT ALARM JUN 2, 2009 8:23 All DEC 9, 2010 10:04 AM JUL 22, 2008 2:07 PM HIGH PRODUCT ALARM OCT 9, 2009 9:39 AM ALARM HISTORY REPORT FEB 22, 2007 8:36 AM OCT 18, 2006 9:36 AM ----- SENSOR ALARM ----- L 4:SATELITE DISP PAN S DISPENSER PAN SENSOR OUT ALARM FEB 10, 2011 10: 16 AM FUEL ALARM FEB 10, 2011 10:12 AM FUEL ALARM DEC 9, 2010 9:58 AM ALARM HISTORY REPORT ----- SENSOR ALARM ----- ALARM HISTORY REPORT L 7:ANNULAR 2 TANK ANNULAR SPACE ----- SENSOR ALARM ----- SENSOR OUT ALARM L 5:ANNULAR 1 TANK FEB 10, 2011 10: 16 AM ANNULAR SPACE LOW LIQUID ALARM SENSOR OUT ALARM FEB 10, 2011 10: 11 AM FEB 10, 2011 10: 16 AM LOW LIQUID ALARM LOW LIQUID ALARM FEB 10, 2011 10:09 All FEB 10, 2011 10: 10 AM LOW LIQUID ALARM DEC 9, 2010 9:54 AM * END * * END ALARM HISTORY REPORT ----- SENSOR ALARM ----- ALARM HISTORY REPORT L B:STP SUMP 2 TANK STP SUMP -- SENSOR ALARM ----- SENSOR OUT ALARM L 6:STP SUMP 1 TANK FEB 10, 2011 10:16 AM STP SUMP LIQUID WARNING SENSOR OUT ALARM FEB 10, 2011 10: 11 AM FEB 10, 2011 10:16 AM SENSOR OUT ALARM FEB 10, 2011 10:1. FUEL ALARM DEC 9, 2010 10:04 AM 0 AM FUEL ALARM DEC 9, 2010 9:56 AM ri n END n PENSKE BAKERSFIELD 2929 E, BRUNDAGE LANE BAKERSFIELD CA 93307 02/10/2011 11:09 AM SUMP LEAK TEST REPORT NFILBKT TEST STARTED 10:54 AM TEST STARTED 02/10/2011 BEGIN LEVEL 4,5531 IN END TIME 11:09 AM END DATE 02/10/2011 END LEVEL 4.5525 IN LEAK THRESHOLD 0,002 IN TEST RESULT PASSED PENSKE BAKERSFIELD 2929 E, BRUNDAGE LANE BAKERSFIELD CA 93307 02/10/2011 11:24 AM SUMP LEAK TEST REPORT NFILBKT TEST STARTED 11:09 AM TEST STARTED 02/10/2011 BEGIN LEVEL 4,5525 IN END TIME 11:24 AM END DATE 02/10/2011 END LEVEL 4,5523 IN LEAK THRESHOLD 0.002 IN_ TEST RESULT PASSED WORK ORDER Tank Specialists of California e 560 Birch Street, Building #3 Lake Elsinore, CA 92530 (888) 606-TANK (8265) FAX (951) 245-2886 DATE License#745065 A,B-HAZ ❑A.M. ❑ P.M. BILL TO PHONE ADDRESS TECHNICIAN CITY LABORER JOB NAME AND LOCATION CONTACT NAME&#: DESCRIPTION OF WORK QUANTITY DESCRIPTION OF WORK PERFORMED Z ZZ X5012 P/4fi5E_D t OP— cq"-r 3 s�NSo2 0, s�e9 3 o r s�.vso2 Pi4 ss .'00 ZO S�NSvlZ /0 -1�rP �uca' 7 ADDITIONAL WORK REQUIRED - s�-� PARTS USED HOURS LABOR AMOUNT TOTAL TECHNICIAN @ MATERIALS LABORER @ TOTAL LABOR I h e acknowledge the satisfactory TOTAL LABOR TAX co e n of the ab=described work. SIGNATURE y DATE COMPLETED TOTAL TANK SPECIALISTS OF CALITORNIA s YOUR PARTNER IN A GREENER ENVIRONMENT r February 23, 2011 Bakersfield Fire Prevention Services Attn: Inspector-Ernie Medina 2101 "H" Street Bakersfield, CA 93301 Re: Test Results Please find attached test results for the following facilities housing fuel storage systems: TSOC Client Name Results for this testing: Date of Test Penske Truck Leasing Monitoring Certification 2/10/2011 2929 E. Brundage Lane Bakersfield, CA 93307 Please note we will mail the original copies of these results to our customers for them to have on site at their facility if you should need to review the results during your inspections. If you have any questions or concerns, please give me a call. Thank you, TANK SPECIALISTS OF CALIFORNIA George Aguilar Testing and Maintenance Coordinator WWW.TANK-SPECIALISTS.COM LIC. #745065 A, 9-HAZ P: (888) 606-TANK(8265) • F: (951) 245-2886 • 560 BIRCH STREET, BUILDING #3 • LAKE ELSINORE, CA 92530