Loading...
HomeMy WebLinkAbout2011 FMC RESULTS Appendix VI (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.waterboards.ca.gov) Monitoring System Certification For Use By All Jurisdictions Within the State of California Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility: Pacific Bell Telephone Co. dba AT&T Califomia GEO PAR#SA098 Address: 3221 S. "H" STREET City: BAKERSFIELD Zip: 93304 Facility Contact Person: Grant Armstrong Contact Phone No: 661-327-6903 Make/Model of Monitoring System: TLS 350 Service Date: 01/20/2011 B. Inventory of Equipment Tested/Certified IIIIIIIIIIIIIIIIIIII 23 Check the appropriate boxes to indicate specific equipment Inspected/serviced: IE Tank ID: SA0980001 Tank ID: ®In-Tank Gauging Probe Model:847390-107 ❑In-Tank Gauging Probe Model: ®Annular Space or Vault Sensor Model:794390-420 ❑Annular Space or Vault Sensor Model: ®Piping Sump/Trench Sensor(s) Model:794380-208 ❑Piping Sump/Trench Sensor(s) Model: ®Fill Sump Sensor(s) Model:794380-208 ❑Fill Sump Sensor(s) Model: ❑Mechanical Line Leak Detector Model: ❑Mechanical Line Leak Detector Model: ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: ®Tank Overfill/High Level Sensor Model:790091-001 ❑Tank Overfill/High Level Sensor Model: ®Other(Specify equipment type and model in Section E on Page 2) ❑Other(Specify equipment type and model in Section E on Page 2) Tank ID: Tank ID: ❑In-Tank Gauging Probe Model: ❑In-Tank Gauging Probe Model: ❑Annular Space or Vault Sensor Model: ❑Annular Space or Vault Sensor Model: ❑Piping Sump/Trench Sensor(s) Model: ❑Piping Sump/Trench Sensor(s) Model: ❑Fill Sump Sensor(s) Model: ❑Fill Sump Sensor(s) Model: ❑Mechanical Line Leak Detector Model: ❑Mechanical Line Leak Detector Model: ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: ❑Tank Overfill 1 High Level Sensor Model: ❑Tank Overfill/High Level Sensor Model: ❑Other(Specify equipment type and model in Section E on Page 2) ❑Other(Specify equipment type and model in Section E on Page 2) Dispenser ID: Dispenser ID. . ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: ❑Shear Valve(s) ❑Shear Valve(s) ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) Dispenser ID: Dispenser ID: ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: ❑Shear Valve(s) ❑Shear Valve(s) ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) Dispenser ID: Dispenser ID: ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: ❑Shear Valve(s) ❑Shear Valve(s) ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. C. Certification-I certify that the equipment identified in this document was inspected/serviced In accordance with the manufacturers'guidelines.Attached to this Certification is informatlon (e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,1 have also attached a copy of the report; (check all that apply): Sy set-up ®Alarm history report Technician Name (Print): R. Harrebomee Si nature: Certification No: A24768 I License No: 588098 Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No: 714 560-8222 Testing Company Address: 2131 South Dupont Drive Anaheim CA 92806 Date of Testing/Servicing: 01/20/2011 Monitoring System Certification Page 1 of 4 12/07 1 IIIIIIIIIIIIIIIIIIII 24 2/21/07 IE Monitoring System Certification Address: 3221 S. "H"STREET BAKERSFIELD 93304 Service Date: 01/20/2011 D. Results of Testing/Servicing Software Version Installed: 324.01 Complete the foll owina checklist: •Yes ❑No* Is the audible alarm operational? •Yes ❑ No* Is the visual alarm operational? •Yes ❑ No* Were all the sensors visually inspected,functionally tested, and cofirmed operational? •Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other e ui ment will not interfere with their proper operation? ®Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g. modem) operational? ❑ N/A ❑Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes:which sensors initiate positive shut- ❑ Sump/Trench Sensors ❑ Dispenser Containment Sensors ®N/A down?: Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ❑ Yes ❑No ❑Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the ® N/A tank fill point(s)and operating properly?If so, at what percent of tank capacity does the alarm trigger?: ❑Yes* M No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E below. Was liquid found inside any secondary containment systems designed as dry systems? El Yes* ® No If yes,check the type(s)of liquid found and describe causes in Section E,below. ❑Product ❑ Water •Yes ❑ No* lWas monitoring system set-up reviewed to ensure proper settings?Attach set up reports, if applicable •Yes ❑ No* I Is all monitoring equipment operational per manufacturer's specifications? *In Section E below,describe how and when these deficiencies were or will be corrected. E. Comments Other Sensors from page 1: Transition Sump Sensor 794380-208 Certified. Piping Pan Sensor 794390-420 Certified. An Overfill Prevention Valve is installed in the Drop Tube. Monitoring System Certification Page 2 of 4 12/07 2 2/21/07 Monitoring System Certification Address: 3221 S. "H"STREET BAKERSFIELD 93304 Service Date: 01/20/2011 F. In-Tank Gauging/SIR Equipment ®Check this box if tank gauging is used only for inventory control ❑Check this box if no tank gauging or SIR Equipment is installed This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring Complete the fol owinci checklist ❑Yes ❑ No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? ❑Yes ❑ No* Were all tank gauging probes visually inspected for damage and residue buildup? ❑Yes ❑ No* Was accuracy of system product level readings tested? ❑Yes ❑ No* Was accuracy of system water level readings tested? ❑Yes ❑ No* Were all probes reinstalled properly? ❑Yes ❑ No* lWere all items on the equipment manufacturer's maintenance checklist completed? * In the Section H below, describe how and when these deficiencies were or will be corrected G. Line Leak Detectors (LLD): ®Check this box if LLDs are not installed Complete the fol owina checklist ❑Yes ❑No* For equipment start-up or annual equipment certification,was a leak simulated to verify LLD performance? ❑ N/A Simulated Leak Rate(check all that apply) ❑3.0 g.p.h ❑0.1 g.p.h ❑0.2 g.p.h ❑Yes ❑ No* Were all LLDs confirmed operational and accurate within regulatory requirements? ❑Yes ❑ No* Was the testing apparatus properly calibrated? ❑Yes ❑ No* For mechanical LLDs, does the LLD restrict product Flow if it detects a leak? ❑ N/A ❑Yes ❑ No* For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? ❑ N/A ❑Yes. ❑ No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ❑ N/A ❑Yes ❑ No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? ❑ N/A ❑Yes ❑ No* For electronic LLDs, have all accessible wiring connections been visually inspected? ❑ N/A ❑Yes ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? *In the Section H below, describe how and when these deficiencies were or will be corrected H. Comments Suction System. Monitoring System Certification Page 3 of 4 12107 3 2/21/07 Monitoring System Certification Address: 3221 S. "H"STREET BAKERSFIELD 93304 Service Date: 01/20/2011 UST monitoring Site Plan clt&t Monitoring Plan Site Map Drawing NOT to Scale Business Name: Pacific Bell Telephone Co. dba AT&T Cal. (SA098) Plpkp FWSWVW+ sump wl I + i i : � AnnuM Sensor + Tranl$w Sump 9K UST Oiesel AW Sena + f _.:.. Fuel Um VW Rlser �- I 1 �r P �. --OwU AW. Li L. Erohe Room TLS 360nI'Fk. AT&T building N E S Date map was drawn: 01/20/2011 Instructions If you already have a diagram that shows all required information, you may include it, rather than this page, with your Monitoring System Certification. On your site plan, show the general layout of tanks and piping. Clearly identify locations of the following equipment, if installed: monitoring system control panels; sensors monitoring tank annular spaces, sumps, dispenser pans, spill containers, or other secondary containment areas; mechanical or electronic line leak detectors; and in-tank liquid level probes (if used for leak detection). In the space provided, note the date this Site Plan was inspected. Monitoring System Certification Page 4 of 4 12/07 4 2/21/07 SWRCB,January 2006 SPILL BUCKET TESTING REPORT FORM This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printout from tests(if applicable),should be provided to the facility owner/operator for submittal to the local regulatory agency. 1.FACILITY INFORMATION Facility Name: Pacific Bell Telephone Co.dba AT&T California Date of Testing:01/20/2011 Facility Address: 3221 S. "H"STREET BAKERSFIELD CA 93304 GEO PAR#SA098 Facility Contact:Grant Armstrong Facility Phone: 661-327-6903 Date Local Agency Was Notified of Testing:01/04/2011 Name of Local Agency Inspector if present during testing): Esther Duran 2.TESTING CONTRACTOR INFORMATION Company Name:TAIT ENVIRONMENTAL SERVICES Technician Conducting Test:R.Harrebomee Credentials: ®CSLB Contractor ®ICC Service Tech ❑SWRCB Tank ❑Other(Specify) Tester License Number (s):A ASB HAZB C-10; 588098• ICC#5252138-UT 3.SPILL BUCKET TESTING INFORMATION Test Method Used ®Hydrostatic ❑Vacuum ❑Other Test Equipment Used:Tape Measure E ui ment Resolution: 1/16" Identify Spill Bucket(By Tank Number, 1 SA098UO01 2 3 4 Stored Product,etc) ❑Direct Bury ❑Direct Bury El Direct Bury E]Direct Bury Bucket Installation Type ®Contained in Sump ❑Contained in Sump ❑Contained in Sump ❑Contained in Sump ❑On top of AST ❑On top of AST ❑On top of AST ❑On top of AST Bucket Diameter inches 11" Bucket Depth inches 14" Wait Time between applying 30 Min vacuum/water and start of test Test Start Time: 9:30 am Initial Reading Ri): 9" Test End Time: 10:30 am Final Reading 9" Test Duration: 1 Hour Chan a in Reading Rf-Ri : 0 Pass/Fail Threshold or Criteria: 0 Test Result Pass Comments:Test water removed from site and taken to the shop. CERTIFICATION OF TE HNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the infor ai ed in this report is true,accurate and in full compliance with legal requirements Technician's Signature " Date 01/20/2011 JAN 26, 2011 12:54 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 4784 2 4784 3 0 4 0 162300 JAN 26, 2011 12:54 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 4532 2 4532 3 0 4 0 162400 JAN 26, 2011 12:54 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA098U001 2.0 162800 JAN 26,2011 12:54 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 6016 2 5036 3 0 4 0 162900 JAN 26, 2011 12:54 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 3000 2 3525 3 0 4 0 170300 JAN 26, 2011 12:54 PM LIQUID TYPE SENSOR LOCATION TYPE 1 ANNULAR SPACE SENSOR TRI-STATE (SINGLE FLOAT) 2 FILL SUMP SENSOR TRI-STATE (SINGLE FLOAT) 3 PIPING SUMP SENSOR TRI-STATE (SINGLE FLOAT) 4 TRANSITION SUMP TRI-STATE (SINGLE FLOAT) 5 PIPING PAN TRI-STATE (SINGLE FLOAT) 6 ANNULAR SPACE TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) I90200 JAN 26, 2011 12:54 PM SOFTWARE REVISION LEVEL VERSION 324.01 SOFTWARE# 346324-100-B CREATED - 03.11.10.17.15 S-MODULE# 330160-002-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD I11100 JAN 26, 2011 12:54 PM BKFDCA14 SA098 I50301 JAN 26, 2011 12:53 PM # 1:BKFDCAI4 SA098 ❑ I50302 JAN 26, 2011 12:53 PM # 2:3221 S. H ST. Fl I50303 JAN 26, 2011 12:53 PM # 3:BAKERSFIELD,CA 93304 150304 JAN 26, 2011 12:53 PM # 4:661-832-8370 I51700 JAN 26, 2011 12:53 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM 150F00 JAN 26, 2011 12:53 PM MON DD YYYY HH:MM:SS xM I10200 JAN 26, 2011 12:53 PM BKFDCA14 SA098 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163785 162052 2 INTERSTITIAL BD 200879 199688 3 UNUSED 10306571 10231829 4 UNUSED 10265262 10212271 5 UNUSED 10261818 1021.6914 6 UNUSED 10249310 10213220 7 UNUSED 10253984 10208478 8 UNUSED 10247323 10219759 9 RELAY BOARD 14983 14995 10 UNUSED 10251789 10224040 11 UNUSED 10242063 10211496 12 UNUSED 10251033 10213511 13 UNUSED 10239736 10218469 14 UNUSED 10246737 10206814 15 UNUSED 10242820 10219339 16 UNUSED 10238506 10214301 COMM 1 FAXMODEM BOARD 40172 40120 COMM 2 UNUSED 10240833 10214419 COMM 3 UNUSED 10246661 10215427 COMM 4 UNUSED 10237503 10218884 COMM 5 UNUSED 10242385 10206616 COMM 6 UNUSED 10240341 10218311 I60100 JAN 26, 2011 12:53 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 DIESEL TK#SA098U001 ON 2 OFF 3 OFF 4 OFF 160200 JAN 26, 2011 .12:53 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 DIESEL TK#SA098U001 2 3 4 160300 JAN 26, 2011 12:53 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 DIESEL TK#SA098U001 1 2 2 3 3 4 4 160400 JAN 26, 2011 12:53 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 6016 2 5036 3 0 4 0 I60700 JAN 26, 2011 12:54 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA098U001 95.75 2 92.00 3 0.00 4 0.00 160900 JAN 26, 2011 12:54 PM TANK THERMAL COEFFICIENT . TANK PRODUCT LABEL 1 DIESEL TK#SA098U001 0.000450 2 0.000450 3 0.000000 4 0.000000 161200 JAN 26, 2011 12:54 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 DIESEL TK#SA098U001 NONE NONE 2 NONE NONE 3 NONE NONE 4 NONE NONE Fl 162100 JAN 26, 2011 12:54 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 2000 2 3000 3 0 4 0 162200 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 1-20-11 10:18AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 1-20-11 10:14AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM CLEAR 1-20-11 9:50AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 1-20-11 9:49AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 1-20-11 9:48AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM ALARM 1-20-11 9:47AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 1-20-11 9:43AM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM CLEAR 1-20-11 9:42AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 1-20-11 9:42AM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM ALARM 1-20-11 9:41AM T 1 TANK DIESEL TK#SA098U001 LOW PRODUCT ALARM CLEAR 1-20-11 9:35AM T 1 TANK DIESEL TK#SA098U001 LOW PRODUCT ALARM ALARM 1-20-11 9:35AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 1-20-11 9:35AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 1-20-11 9:34AM L 5 PIPE PIPING PAN FUEL ALARM CLEAR 1-20-11 9:30AM L 5 PIPE PIPING PAN FUEL ALARM ALARM 1-20-11 9:27AM L 4 PIPE TRANSITION SUMP FUEL ALARM CLEAR 1-20-11 9:26AM L 4 PIPE TRANSITION SUMP FUEL ALARM ALARM 1-20-11 9:22AM L 4 PIPE TRANSITION SUMP FUEL ALARM CLEAR 1-20-11 9:22AM L 4 PIPE TRANSITION SUMP FUEL ALARM ALARM 1-20-11 9:22AM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM CLEAR 1-20-11 9:21AM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM ALARM 1-20-11 9:17AM L 2 OTHER FILL SUMP SENSOR FUEL ALARM CLEAR 1-20-11 9:17AM L 2 OTHER FILL SUMP SENSOR FUEL ALARM ALARM 1-20-11 9:13AM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM CLEAR 1-20-11 9:12AM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM ALARM 1-20-11 9:09AM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM CLEAR 6-30-10 7:56AM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM ALARM 6-28-10 9:36AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 1-29-10 9:37AM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM CLEAR 1-29-10 9:37AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 1-29-10 9:37AM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM ALARM 1-29-10 9:36AM L 5 PIPE PIPING PAN FUEL ALARM CLEAR 1-29-10 9:34AM L 5 PIPE PIPING PAN FUEL ALARM ALARM 1-29-10 9:30AM L 4 PIPE TRANSITION SUMP FUEL ALARM CLEAR 1-29-10 9:29AM L 4 PIPE TRANSITION SUMP FUEL ALARM ALARM 1-29-10 9:23AM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM CLEAR 1-29-10 9:21AM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM ALARM 1-29-10 9:11AM L 2 OTHER FILL SUMP SENSOR FUEL ALARM CLEAR 1-29-10 9:10AM L 2 OTHER FILL SUMP SENSOR FUEL ALARM ALARM 1-29-10 9:05AM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM CLEAR 1-29-10 9:04AM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM ALARM 1-29-10 8:59AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM CLEAR 1-29-10 8:41AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM ALARM 1-29-10 8:40AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 1-29-10 8:37AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 1-29-10 8:35AM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM CLEAR 12-08-09 8:59AM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM ALARM 12-08-09 8:57AM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM CLEAR 11-13-09 7:53AM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM ALARM 11-13-09 7:52AM 0 111200 JAN 26, 2011 12:55 PM BKFDCA14 SA098 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 1-20-11 10:18AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 1-20-11 10:18AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 1-20-11 9:51AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 1-20-11 9:50AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING CLEAR 1-20-11 9:50AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING ALARM 1-20-11 9:47AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 1-20-11 9:35AM T 1 TANK DIESEL TK#SA098U001 INVALID FUEL LEVEL CLEAR 1-20-11 9:35AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED ALARM 1-20-11 9:35AM T 1 TANK DIESEL TK#SA098U001 INVALID FUEL LEVEL ALARM 1-20-11 9:35AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 1-29-10 9:40AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 1-29-10 9:38AM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM CLEAR 1-29-10 9:38AM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM ALARM 1-29-10 9:35AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING CLEAR 1-29-10 8:41AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING ALARM 1-29-10 8:40AM SYSTEM PRINTER ERROR CLEAR 1-07-10 7:51AM SYSTEM PAPER OUT CLEAR 1-07-10 7:51AM SYSTEM PRINTER ERROR ALARM 1-07-10 7:30AM SYSTEM PAPER OUT ALARM 1-07-10 7:30AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING CLEAR 9-28-09 11:27AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING ALARM 9-28-09 11:26AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING CLEAR 9-28-09 11:26AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING ALARM 9-28-09 11:25AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING CLEAR 9-28-09 11:15AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING ALARM 9-28-09 11:14AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING CLEAR 9-28-09 11:14AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING ALARM 9-28-09 11:14AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING CLEAR 9-28-09 11:14AM SYSTEM PRINTER ERROR CLEAR 9-28-09 11:09AM SYSTEM PAPER OUT CLEAR 9-28-09 11:09AM SYSTEM PRINTER ERROR ALARM 9-28-09 11:09AM SYSTEM PAPER OUT ALARM 9-28-09 11:09AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING ALARM 9-28-09 11:09AM SYSTEM PRINTER ERROR CLEAR 9-28-09 11:09AM SYSTEM PRINTER ERROR ALARM 9-28-09 11:09AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING CLEAR 9-28-09 11:07AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING ALARM 9-28-09 11:04AM L 6 OTHER ANNULAR SPACE SETUP DATA WARNING CLEAR 9-28-09 10:58AM L 6 OTHER ANNULAR SPACE SETUP DATA WARNING ALARM 9-28-09 10:53AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING CLEAR 9-28-09 10:48AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING ALARM 9-28-09 10:46AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING CLEAR 9-28-09 10:45AM L 1 ANNULAR ANNULAR SPACE SENSOR SETUP DATA WARNING ALARM 9-28-09 10:44AM SYSTEM PRINTER ERROR CLEAR 7-06-09 9:45AM SYSTEM PAPER OUT CLEAR 7-06-09 9:45AM SYSTEM PRINTER ERROR ALARM 7-06-09 9:44AM SYSTEM PAPER OUT ALARM 7-06-09 9:44AM SYSTEM PRINTER ERROR CLEAR 2-19-09 10:58AM SYSTEM PRINTER ERROR ALARM 2-19-09 10:58AM 120600 JAN 26, 2011 12:55 PM BKFDCA14 SA098 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 TANK ALARM HISTORY TANK 1 DIESEL TK#SA098U001 SETUP DATA WARNING APR 26, 2004 3:45 PM LEAK ALARM JUN 2, 2006 9:35 AM HIGH WATER ALARM JAN 20, 2011 9:47 AM JAN 29, 2010 8:40 AM OVERFILL ALARM JAN 20, 2011 9:41 AM JAN 29, 2010 9:36 AM FEB 19, 2009 9:49 AM LOW PRODUCT ALARM JAN 20, 2011 9:35 AM FEB 19, 2009 9:48 AM APR 13, 2005 10:14 AM SUDDEN LOSS ALARM JUN 2, 2006 9:04 AM HIGH PRODUCT ALARM JAN 29, 2010 9:35 AM MAR 29, 2006 11:48 AM APR 13, 2005 10:14 AM INVALID FUEL LEVEL JAN 20, 2011 9:35 AM FEB 19, 2009 9:48 AM APR 13, 2005 10:13 AM PROBE OUT JAN 20, 2011 10:14 AM JAN 20, 2011 9:48 AM JAN 20, 2011 9:42 AM HIGH WATER WARNING JAN 20, 2011 9:47 AM JAN 29, 2010 8:40 AM DELIVERY NEEDED JAN 20, 2011 9:35 AM FEB 19, 2009 9:48 AM MAY 11, 2006 1:42 PM MAX PRODUCT ALARM MAR 29, 2006 11:48 AM PERIODIC TEST FAIL JUN 14, 2006 1:38 AM JUN 3, 2006 9:55 AM MAY 11, 2006 7:55 AM CSLD INCR RATE WARN NOV 9, 2004 11:34 AM OCT 23, 2004 10:39 AM LOW TEMP WARNING JAN 20, 2011 10:18 AM JAN 20, 2011 9:50 AM JAN 29, 2010 9:38 AM I30200 JAN 26, 2011 12:56 PM BKFDCA14 SA098 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 ANNULAR SPACE SENSOR JAN 20, 2011 9:09 AM FUEL ALARM JAN 29, 2010 8:59 AM FUEL ALARM DEC 8, 2009 8:57 AM FUEL ALARM 2 FILL SUMP SENSOR JAN 20, 2011 9:13 AM FUEL ALARM JAN 29, 2010 9:05 AM FUEL ALARM FEB 19, 2009 9:40 AM FUEL ALARM 3 PIPING SUMP SENSOR JAN 20, 2011 9:17 AM FUEL ALARM JUN 28, 2010 9:36 AM FUEL ALARM JAN 29, 2010 9:11 AM FUEL ALARM 4 TRANSITION SUMP JAN 20, 2011 9:22 AM FUEL ALARM JAN 20, 2011 9:22 AM FUEL ALARM JAN 29, 2010 9:23 AM FUEL ALARM 5 PIPING PAN JAN 20, 2011 9:27 AM FUEL ALARM JAN 29, 2010 9:30 AM FUEL ALARM FEB 19, 2009 9:09 AM FUEL ALARM El f TAIT RISING 10 rrte a+[nueiraa 2181 S. Dup,nm Drive,.Anoheim, CA 92806 p:71d;S60r8%'L^< tv•.,rr.toit.com January 27, 2011 VIA FED EX: 7967 0484 8100 Bakersfield Fire Department 2101 H Street Bakersfield CA 93301 Re: Monitoring System Certification Spill Bucket Testing Pacific Bell Telephone Co. dba AT&T California 3221 S. H STREET, BAKERSFIELD, CA GEOPAR: SA098 To Whom It May Concern: Enclosed are the results for the following tests completed on January 20, 2011: • Monitoring System Certification Report Form • Spill Bucket Testing Report Form Please do not hesitate to call me if you have any questions. 'IgheTr I o rs, enison ram Manager CA 11cd 588098 i AZ link 0959841 NV link 0049666 1 TX Itck CR0000041