Loading...
HomeMy WebLinkAbout2010 FMC RESULTS MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited.,Chapter 6.7,Health and Safety Code;Chapter 16, Division 3 Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment If more than one monitoring system control panel is installed at the facility,a separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A-General Information Facility Name: VALERO 3074 City: BAKERSFIELD CA Zip:93301 Site Address: 3225 BUCK OWENS BLVD. Contact Phone No: 324-9481 HWY 99/HWY 58 Date of Test ng/Service: 07/01/2010 Facility Contact Person: MANAGER-JOEL Make/Model of Monitoring System:TLS-350 Work Order Number: 2275545 IIIIIIIIIIIIIIIIIIII B.Inventory of Equipment Tested/Certified 67 Check the appropriate boxes to indicate specific equipment inspected/serviced IE Tank ID: T-1 Tank ID: T-2 X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG X Annular Space or Vault Sensor. Model: 420 Annular Space or Vault Sensor. Model: 420 X Piping Sump/Trench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: 208 X Fill Sump Sensor(s). Model: 208 208 FX1 V Fill Sump Sensor(s). Model: X Mechanical Line Leak Detector. Model: X Mechanical Line Leak Detector. Model: FX1 V Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: X Tank Overfill/High-Level Sensor. Model: E/A Tank OverfilUHigh-Level Sensor. Model: E/A Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). Tank ID: TanklD: In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: X Annular Space or Vault Sensor. Model: 420 Annular Space or Vault Sensor. Model: X Piping Sump/Trench Sensor(s). Model: 208 Piping Sumprrrench Sensor(s). Model: X Fill Sump Sensor(s). Model: 208 Fill Sump Sensor(s). Model: X Mechanical Line Leak Detector. Model: FX1 DV Mechanical Line Leak Detector. Model: Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: Tank Overfill/High-Level Sensor. Model: E/A Tank Overfill/High-Level Sensor. Model: Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). Dispenser ID: 1/2 Dispenser ID: 3/4 ❑Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s) Model: ❑Shear Valve(s). _X-1 Shear Valve(s) QDispenser Containment Float(s)and Chain(s). :X71 Dispenser Containment Float(s)and Chain(s). Dispenser ID: 516 Dispenser ID: 7/8 ❑Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: XD Shear Valve(s). 71 Shear Valve(s). FX-1 Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). Dispenser ID: 9110 Dispenser ID: 11/12 Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: XD Shear Valve(s). X Shear Valve(s). ❑ Dispenser Containment Float(s)and Chain(s). X Dispenser Containment Float(s)and Chain(s). 'If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. C. Certification I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the(Check all that apply): ❑X System set-up Alarm history report Technician Name(print): JON ADAMS Signature: Certification No.: B37367 License.No.: 743160(Class'A'General Enginering Contractor License) Testing Company Name:Tanknology Phone No.: (800)800-4633 Site Address: 11000 N.MoPac Expressway,suite 500,Austin,TX 78759 Date of Testing/Servicing: 07/01/2010 Monitoring System Certification Page 1 of 3 IIIIIIIIIIIIIIIIIIII 68 Based on CA form dated 03/08 IE Monitoring System Certification Site Address 3225 BUCK OWENS BLVD. Date of Testing/Service: 07/01/2010 HWY 99/HWY 58 D. Results of Testing/Servicing Software Version Installed: Complete the following checklist: X Yes No• Is the audible alarm operational? Q Yes ❑No' Is the visual alarm operational? Q Yes No• Were all sensors visually inspected,functionally tested,and confirmed operational? Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not Q Yes ❑No interfere with their proper operation? Yes No• X N/A If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment Q Yes ❑No• ❑N/A monitoring system detects a leak,fails to operate,or is electrically disconnected?If yes:which sensors initiate positive shut-down?(check all that apply) ❑x Sump/Trench Sensors; ❑ Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ❑x Yes No ❑ Yes [:]No ❑N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.:no mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill points(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? so ❑ Yes' ❑x No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E,below. ❑ Yes- ❑x No Was liquid found inside any secondary containment systems designed as dry systems?(check all that apply) ❑Product; ❑ Water. If yes,describe causes in Section E,below. Yes ❑No Was monitoring system set-up reviewed to ensure proper settings?Attach set-up reports,if applicable. ❑X Yes ❑No• Is all monitoring equipment operational per manufacturers'specifications? In Section E below,describe how and when these deficiences were or will be corrected. E. Comments: Page 2 of 3 Based on CA form dated 03/08 Monitoring System Certification Site Address: 3225 BUCK OWENS BLVD. Date of Testing/Service: 07101/2010 HWY 991HWY 58 F. In-Tank Gauging / SIR Equipment ❑ Check this box if tank gauging is used only for inventory control. ❑ Check this box if no tank gauging or SIR equipment is installed. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: 0 Yes ❑No• Has all input wiring been inspected for proper entry and termination,including testing for ground faults? 0 Yes ❑No• Were all tank gauging probes visually inspected for damage and residue buildup? EYes ❑No• Was accuracy of system product level readings tested? El Yes ❑No• Was accuracy of system water level readings tested? x Yes F-]No= Were all probes reinstalled properly? ❑X Yes I [:]No• Were all items on the equipment manufacturers'maintenance checklist completed? In the Section H,below,describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD) : ❑ Check this box if LLDs are not installed. Complete the following checklist: For equipment start-up or annual equipment certification,was a leak simulated to verify LLD performance? Q Yes ❑No• ❑N/A (Check all that apply)Simulated leak rate: ❑ 3 g.p.h❑0.1 g.p.h ❑0.2 g.p.h X Yes ❑No= Were all LLDs confirmed operational and accurate within regulatory requirements? x Yes ❑No= Was the testing apparatus properly calibrated? ❑ x Yes ❑No• ❑N/A For mechanical LLDs,does the LLD restrict product flow if it detects a leak? ❑Yes ❑No• ❑x N/A For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? ❑Yes ❑No• ❑X N/A For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ❑Yes ❑No• ❑X N/A For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? ❑Yes ❑No= Q N/A For electronic LLDs,have all accessible wiring connections been visually inspected? Yes ❑No• Were all items on the equipment manufacturers'maintenance checklist completed? In the Section H,below,describe how and when these deficiencies were or will be corrected. H. Comments: Page 3 of 3 Based on CA form dated 03/08 SITE DIAGRAM J'pp Tanknokogy 8501 N MOPAC EXPRESSWAY,SUITE 400 AUSTIN,TEXAS 78759 (512)451-6334 FAX(512)459-1459 TEST DATE: 07/01/10 WORK ORDER NUMBER2 2 7 5 5 4 5 CLIENTNALERO SITE: VALERO 3074 L 7 sump IY 9 10 11 12 13 -4 a) �I\lo W J 1 E O SO LL 9 0 1 2 S S S S S C-STORE A A A A T T T A MONITOR CD � Co Co r') co T 5 T A X P ENT CD O 00 VENTS REG o CA #3 L Co S STP IF I a O VALERO 3074 14K 0 3225 Buck Owens Blvd. sTP'�10 L UF� I Bakersfield, CA CAR WASH I PREM DSL Printed 07/09/2010 08:14 ACRAMER Work Order: 2275545 (I%Sf}�R�$t)�CS[lR6•I'o[m-�'175IU11 t-T.6.'�UId Emergency Shut Off (ESO) Dispenser Emergency Shutoff Valve (ESV) ANNUAL TEST RECORD LOCATIONS AND TEST DATA Testing TANKNOLOGY Company: Date: Location Name: TZA�"*?t� Store* 3o?--( State PD i!: Address: ,'� 7uc ,'4"r City: State: e4 Emergency Shut Off(ES01'Vesting Results on 0 in accordance with"ESC}Vendor Letter(3-21-05).doc",from Retail Compliance Department, as a part of annual compliance testing, this representative tested the Emergency Shut Ofd' ESO switches indicated on this sketch. Findings fisted below: Emergency Shut Off(ESO) lr No,Provide OPM,tional7 N I Maintenarme Log Date Called Dispenser Emergeney Shutoff Valve (ESD 'Testing Results On -7—f`'O in accordance with NFPA 30A this representative tested the automatiGclosing feature of the Dispenser Emergency Shutoff VALVE(S)(ESV)located in the supply lines at thIp base of each individual island type dispenser indicated on the diagrain below. Each device(4)j Y in all, would automatically close. Findings listed below: Disp.Emergency Shut Off ff No,Provide Valve(ESV)Opmaonal2 1 N Maintenarme Lag 1 Date Called Site vinp Qf iAMion Md Ph,;*�of N irxv Tcgal: Signature Of Representative: 'r -S Tanknology Inc. 11000 N.MoPac Expressway,Suite 500,Austin,Texas 78759 Work Order: 2275545 RJ LD TW Repod(2-ma)(3).doc RJ = LEAK DETECTOR TEST REPORT COMPIF060p Of MAI report M MgWmd for all mechanical leak detector testkw Valero Location Testin Com an store� 44" Date of Test Address: Address; ZZ Technician fame(print): G1 State: City I State: Technician Certification 9: �(C�.S � c.40 � Test Equipment Used Test Method Used Make/Model ❑ AVO FTA ❑ FXT (RJ 21) (RJ 20) (RJ 051-272-1) Type of Leak Detectors tested ❑ XLD ❑ XLP El BFLD ❑ DLD ❑ PLD ❑ BFLD d FX1 ❑ FX1 D ❑ FX2 ❑ FX2D D FX1 BFLD ❑ FX2BFLD K FX1 DV fl FX2DV 9FXIV ❑ FX2V ❑ OTHER TEST ►NFDRMArIGN UL Leak Serial Resiliency Func. Opening Test Meterin Pass UL+ Detector Number (ml) Element Time Leak g PSI Or SU Type (check (sec) Rate Fail DIE (see valve) milmin above) Holding or PS! gal/hr, fi i�►� 10 12 2t:}k Pxti`� 7�4c��t;a ` o L'� t3 1 l lc [ t W A0 -3 4 5 S 7 S Technician Signature: v s Date: 'r� ` d Tanknology Inc. 11000 N.MoPac Expressway,Suite 500,Austin,Texas 78759 ATG Information Work Order# 2275545 110100 JUL 1,2010 2:27 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661-324-9481 SYSTEM STATUS REPORT ' ALL FUNCTIONS NORMAL 120100 JUL 1,2010 2:27 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661-324-9481 IN-TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP i UNLEADED 6084 5968 8046 42.53 0.00 87.15 2 PREMIUM 3856 3788 6284 38.71 0.78 84.79 4 DIESEL 12710 12461 7358 7721 0.00 103.52 130100 JUL 1,2010 2:27 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD.CA 93308 661-324-9481 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 PREMIUM STP SUMP SENSOR NORMAL 2 UNLEADED STP SUMP SENSOR NORMAL 3 UNLEADED INT SENSOR NORMAL 4 PREMIUM INT SENSOR NORMAL 5 DIESEL STP SUMP SENSOR NORMAL 6 DIESEL INT SENSOR NORMAL 7 FILTER SUMP SENSOR NORMAL 8 UNLEADED FVR SUMP SENSOR NORMAL 9 PREMIUM FVR SUMP SENSOR NORMAL 10 DIESEL FVR SUMP SENSOR NORMAL 150301 JUL 1,2010 2:28 PM #1:VALERO 3074 150302 JUL 1,2010 2:28 PM #2:3225 BUCK OWENS 150303 JUL 1,2010 2:28 PM #3:BAKERSFIELD,CA 93308 150304 JUL 1,2010 2:28 PM #4:661-324-9481 0 151700 JUL 1,2010 228 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50F00 2275545 ATG Information Work Order# 2275545 JUL 1,2010 2:28 PM MON DD YYYY HH:MM:SS xM 110200 JUL 1,2010 2:28 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661-324.9481 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE/G.T. 159366 159463 2 INTERSTITIAL BD 199128 198987 3 INTERSTITIAL BD 200111 200098 4 UNUSED 9357814 8580678 5 UNUSED 9359316 8579140 6 UNUSED 9359034 8581022 7 UNUSED 9362068 8578870 8 UNUSED 9362155 8578277 9 RELAY BOARD 14972 14952 10 RELAY BOARD 15018 15006 11 UNUSED 9362143 8579714 12 UNUSED 9362716 8574797 13 UNUSED 9359139 8574673 14 UNUSED 9363293 8576849 15 UNUSED 9357616 8579225 16 UNUSED 9362127 8577272 COMM i SERIAL SAT BD 475630 475325 COMM 2 RS232 SERIAL BD 9362434 15060 COMM 3 PRINTER BOARD 9987 9988 D 160100 JUL 1,2010 2:28 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 PREMIUM ON 3 DIESEL OFF 4 DIESEL ON 160200 JUL 1,2010 2:28 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 DIESEL D 160300 JUL 1,2010 2:28 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 3 3 DIESEL 4 4 DIESEL 4 D 160400 JUL 1,2010 2:28 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 14130 2 PREMIUM 10140 3 DIESEL 20068 4 DIESEL 20068 D 160700 JUL 1,2010 2:28 PM TANK DIAMETER 2275545 ATG Information Work Order# 2275545 TANK PRODUCT LABEL INCHES 1 UNLEADED 95.50 2 PREMIUM 95.50 3 DIESEL 127.50 4 DIESEL 127.50 160900 JUL 1,2010 2:28 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 PREMIUM 0.000700 3 DIESEL 0.000450 4 DIESEL 0.000450 0 161200 JUL 1,2010 2:28 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL MANIFOLDED TANKS 1 UNLEADED NONE 2 PREMIUM NONE 3 DIESEL NONE 4 DIESEL NONE 0 162100 JUL 1,2010 2:28 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 PREMIUM 0 3 DIESEL 2000 4 DIESEL 0 162200 JUL 1,2010 2:28 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 14130 2 PREMIUM 10140 3 DIESEL 20068 4 DIESEL 20068 162300 JUL 1,2010 2:28 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCTLABEL GALLONS 1 UNLEADED 12717 2 PREMIUM 9126 3 DIESEL 18061 4 DIESEL 18061 162400 JUL 1,2010 2:28 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 PREMIUM 2.0 4 DIESEL 2.0 0 162800 JUL 1,2010 2:28 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 14130 2 PREMIUM 10140 3 DIESEL 20068 4 DIESEL 20068 2275545 ATG Information . Work Order# 2275545 162900 JUL 1,2010 2:28 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 141 2 PREMIUM 101 3 DIESEL 200 4 DIESEL 200 170300 JUL 1,2010 2:28 PM LIQUID TYPE SENSOR LOCATION TYPE 1 PREMIUM STP SUMP TRI-STATE(SINGLE FLOAT) 2 UNLEADED STP SUMP TRI-STATE(SINGLE FLOAT) 3 UNLEADED INT TRI-STATE(SINGLE FLOAT) 4 PREMIUM INT TRI-STATE(SINGLE FLOAT) 5 DIESEL STP SUMP TRI-STATE(SINGLE FLOAT) 6 DIESEL INT TRI-STATE(SINGLE FLOAT) 7 FILTER SUMP TRI-STATE(SINGLE FLOAT) 8 UNLEADED FVR SUMP TRI-STATE(SINGLE FLOAT) 9 PREMIUM FVR SUMP TRI-STATE(SINGLE FLOAT) 10 DIESEL FVR SUMP TRI-STATE(SINGLE FLOAT) 11 TRI-STATE(SINGLE FLOAT) 12 TRI-STATE(SINGLE FLOAT) 13 TRI-STATE(SINGLE FLOAT) 14 TRI-STATE(SINGLE FLOAT) 15 TRI-STATE(SINGLE FLOAT) 16 TRI-STATE(SINGLE FLOAT) 190200 JUL 1,2010 2:28 PM SOFTWARE REVISION LEVEL VERSION 20.04 SOFTWARE#346020-100-E CREATED-02.12.27.05.00 NO SOFTWARE MODULE SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS IA0100 JUL 1,2010 2:28 PM TYPE CODE LENGTH SERIAL NO. D/CODE TANK 1 UNLEADED MAG C001 96.00 070037 4144 TANK 2 PREMIUM MAG C001 96.00 070035 4144 TANK 4 DIESEL MAG D004 132.00 516815 1804 ❑ LA0200 JUL 1.2010 2:28 PM TANK 1 UNLEADED MAG GRADIENT= 346.3600 TANK 2 PREMIUM MAG GRADIENT= 34B.8600 TANK 4 DIESEL MAG GRADIENT= 394.9500 120600 JUL 1,2010 2:28 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 - 661-324-9481 TANK ALARM HISTORY TANK1 UNLEADED SETUP DATA WARNING DEC 14,2006 1:58 PM HIGH WATER ALARM JUL 1,2010 9:35 AM JUN 23,2009 8:54 AM JUN 12,2008 9:25 AM OVERFILL ALARM JUL 1,2010 9:28 AM JUL 1,2010 9:23 AM OCT 24,2009 2:48 PM LOW PRODUCT ALARM JUN 26,2007 12:01 PM INVALID FUEL LEVEL JUL 1,2010 9:21 AM 2275545 ATG Information Work Order# 2275545 JUN 12,2008 9:27 AM JUN 26,2007 12:01 PM PROBE OUT JUL 1,2010 9:51 AM JUL 1,2010 9:20 AM JUN 23,2009 9:02 AM HIGH WATER WARNING JUL 1,2010 9:35 AM JUN 23,2009 8:54 AM JUN 12,2008 9:25 AM MAX PRODUCT ALARM JUL 1,2010 9:43 AM JUN 23,2009 9:00 AM JUN 14,2008 3:10 PM TANK 2 PREMIUM SETUP DATA WARNING DEC 14,2006 1:58 PM HIGH WATER ALARM JUL 1,2010 928 AM JUN 23,2009 9:07 AM JUN 12,2008 921 AM OVERFILL ALARM JUL 1,2010 9:46 AM JUL 1,2010 9:38 AM JUL i,2010 9:29 AM LOW PRODUCT ALARM JUN 26,2007 12:01 PM APR 27,2007 3:18 PM MAR 17,2007 9:22 AM , INVALID FUEL LEVEL JUL 1,2010 9:51 AM JUL 1,2010 9:20 AM MAR 30,2009 10:53 AM PROBE OUT JUL 1,2010 9:51 AM JUL 1,2010 9:37 AM JUL 1,2010 9:20 AM HIGH WATER WARNING JUL 1,2010 9:28 AM JUN 23,2009 9:07 AM JUN 12,2008 9:21 AM MAX PRODUCT ALARM JUN 23,2009 9:00 AM JUN 12,2008 9:24 AM JUN 26,2007 11:54 AM TANK 4 DIESEL HIGH WATER ALARM JUL 1,2010 12:37 PM JUN 23,2009 12:07 PM JUN 12,2008 12:32 PM OVERFILL ALARM JUL 1,2010 11:40 AM JUN 28,2010 3:48 PM MAY 14,2010 9:17 AM LOW PRODUCT ALARM JUN 26,2007 11:04 AM MAR 26,2007 6:38 PM INVALID FUEL LEVEL APR 24,2010 7:52 PM APR 24,2010 6:55 PM APR 24,2010 6:39 PM . PROBE OUT JUL 1,2010 12:55 PM JUL 1,2010 11:39 AM MAY 13,2010 10:46 AM HIGH WATER WARNING JUL 1,2010 11:48 AM APR 24,2010 6:44 PM APR 24,2010 6:38 PM DELIVERY NEEDED APR 24,2010 7:52 PM APR 24,2010 6:56 PM APR 24,2010 6:39 PM MAX PRODUCT ALARM JUL 1,2010 11:41 AM APR 26,2010 11:42 AM JUN 23,2009 12:08 PM LOW TEMP WARNING APR 24,2010 6:56 PM APR 24,2010 1:49 PM APR 24,2010 9:29 AM 160100 JUL 1,2010 2:29 PM LIQUID DIAGNOSTIC REPORT SAMPLE HIGH LOW SENSOR COUNTER REF REF VALUE 1 5 5069 757 90979 2 5 5070 757 100090 3 5 5072 757 100282 4 5 5072 757 100935 5 5 5067 758 100189 6 5 5068 757 99458 7 5 5067 758 100227 8 5 5069 758 100709 2275545 ATG Information Work Order# 2275545 9 5 5075 762 100646 10 5 5074 761 100248 11 5 5078 762 999999680 12 5 5072 762 999999680 13 5 5074 761 975834112 14 5 5077 760 977652096 15 5 5080 760 943268480 16 5 5077 760 968752768 O 130200 JUL 1,2010 2:29 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661-324-9481 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 PREMIUM STP SUMP JUL 1,2010 12:11 PM SENSOR OUT ALARM JUL 1,2010 9:18 AM FUEL ALARM MAR 8,2010 7:28 PM FUEL ALARM 2 UNLEADED STP SUMP JUL 1,2010 12:11 PM SENSOR OUT ALARM JUL 1,2010 9:17 AM FUEL ALARM JUN 23,2009 10:02 AM SENSOR OUT ALARM 3 UNLEADED INT JUL 1,2010 12:11 PM SENSOR OUT ALARM JUL 1,2010 9:16 AM FUEL ALARM JUN 23,2OD9 10:02 AM SENSOR OUT ALARM 4 PREMIUM INT JUL 1,2010 12:11 PM SENSOR OUT ALARM JUN 23,2009 10:02 AM SENSOR OUT ALARM JUN 23,2009 9:34 AM FUEL ALARM 5 DIESEL STP SUMP JUL 1,2010 12:11 PM SENSOR OUT ALARM JUL 1,2010 11:31 AM FUEL ALARM AUG 13,2009 7:08 AM FUEL ALARM 6 DIESEL INT JUL 1,2010 12:11 PM SENSOR OUT ALARM JUL 1,2010 11:34 AM FUEL ALARM JAN 22,2010 1:36 PM FUEL ALARM 7 FILTER SUMP JUL 1,2010 12:11 PM SENSOR OUT ALARM JUL 1,2010 12:04 PM FUEL ALARM JUN 23,2DO9 10:39 AM FUEL ALARM 8 UNLEADED FVR SUMP JUL 1,2010 12:11 PM SENSOR OUT ALARM JUL 1,2010 9:15 AM FUEL ALARM JUN 23,2009 10:02 AM SENSOR OUT ALARM 9 PREMIUM FVR SUMP JUL 1,2010 12:11 PM SENSOR OUT ALARM JUL 1,2010 9:14 AM FUEL ALARM JUN 23,2009 10:02 AM SENSOR OUT ALARM 10 DIESEL FVR SUMP JUL 1,2010 12:11 PM SENSOR OUT ALARM JUL 1,2010 11:32 AM FUEL ALARM JAN 23,2010 6:30 PM FUEL ALARM 120700 JUL 1,2010 2:29 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661-324-9481 TANK LEAK TEST HISTORY T 1:UNLEADED LAST GROSS TEST PASSED: NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME N VOLUME TEST TYPE TANK LEAK TEST HISTORY 2275545 ATG Information Work Order# 2275545 T 2:PREMIUM LAST GROSS TEST PASSED: NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME %VOLUME TEST TYPE TANK LEAK TEST HISTORY T 4:DIESEL LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME %VOLUME TEST TYPE 130100 JUL 1,2010 2:29 PM VALERO 3074 3225 BUCK OWENS BAKERSFIELD,CA 93308 661-324-9481 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 PREMIUM STP SUMP SENSOR NORMAL 2 UNLEADED STP SUMP SENSOR NORMAL 3 UNLEADED INT SENSOR NORMAL 4 PREMIUM INT SENSOR NORMAL 5 DIESEL STP SUMP SENSOR NORMAL 6 DIESEL INT SENSOR NORMAL 7 FILTER SUMP SENSOR NORMAL B UNLEADED FVR SUMP SENSOR NORMAL 9 PREMIUM FVR SUMP SENSOR NORMAL 10 DIESEL FVR SUMP SENSOR NORMAL 130600 JUL 1,2010 229 PM 131100 JUL 1,2010 2:29 PM 134100 JUL 1,2010 2:29 PM 134600 JUL 1,2010 2:29 PM ❑ 134B00 JUL 1,2010 2:29 PM ❑9999FFIB❑ 137400 JUL 1,2010 2:29 PM ❑9999FFlB❑ ❑9999FFIB❑ 2275545 TRITON CONSTRUCTION 2560 Soquel Avenue, Suite 202 Santa Cruz, California 95062 TEL: 831.475.8141 z Te) , N FAX: 831.475.8249 • • June 30, 2010 Inspector, HazMat Division Bakersfield City Fire Dept 2101 H Street Bakersfield, CA 93301 Re: Testing at Valero 3074 3225 Buck owens Boulevard Bakersfield, CA 93301 Dear Inspector: Enclosed are testing results for the above listed site. Please contact Frank Bohnet at 831.227.4730 if you have any questions. Sincere I ZT� Mary Roche 2560 Soquel Avenue Ste 202 - Santa Cruz CA 95062 •,�- T: 831.475.8141 F: 831.475.8249 44 4 CA Lic#693807 A=HAZ 13-HIC Secondary Containment Testing Report Form 1. Facility Information Facility Name: Valero 3074 Date of Testing: 0610112010 Facility Address: 3225 Buck Owens BLVD Bakersfield CA 93308 Facility Contact: Phone: 861-324-9481 Date Local Agency Was Notified of Testing: 05124/2010 Name of Local Agency Inspector(If present during testing): 2. Testing Contractor Information Manufacturer Component Expiration Date Incon Leak Detector 12115110 3. Summa of Test Results Component P i F NT RM Component P F NT RM Spill Buckets:91 &D ❑X ❑ ❑ ❑ ❑ ❑ ❑ ❑ Spill Buckets:87 ❑ ® ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ - ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ o ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ - ❑ ❑ ❑ -- - ❑ - ❑ a ❑ -- ❑ ❑ ❑ ❑ -- -_ ❑ o ❑ ❑ ❑ ❑ ❑ ❑ — -- - ❑- - ❑ ❑ ❑ CERTIFICATION TECHNIC RESPONSIBLE FOR CONDUCTING THIS TESTING To the best of my knowledge,the a is stated in th eu e t are accurate and in full compliance with legal requirements i Technician's Signature: Date: 06/01/2010 Technician's Name: Jonatha Ocker lof2 VALERO 3074 VALERO 3074 3225 BUCK OMENS BLVD 3225 BUCK OHENS BLVD BAKWIELD CA 93308 j BAKERSFIELD CA 93308 661-324 4481 661-324-9481 fi? 06/01/2010• 3:14 PM 06/01/2010 4:02 PM :SUMP_(,O TEST REPORT SUMP LEAK TEST REPORT ?x i SPB)i-D. SPBX-91 TEST STARTED 2:59 PM TEST.STARTED 3:46 PM TEST„STARTED 06/01/2010 ' TEST STARTED 06/01/2010 BEGIN LEVEL 4,2002 IN BEGIN LEVEL 4,1271 IN END TIME 3:14 PM END TIME 4:01 PM END DATE 08/01/2410 END DATE 06/01/2010 END LEVEL 4,2001 IN END LEVEL 4,1269 IN LEAK THRESHOLD 0,002 IN LEAK THRESHOLD 0,002 IN TEST RESULT PASSED 4 ' TEST RESULT PASSED VALERO 3074 3225 BUCK ONENS.BLVD .:,.. BAKERSFIELD CA 93308 661-324-9481 08/01/2010 3:45 PM SUMP LEAK TEST REPORT I SPBX-87 TEST STARTED 3:30 PM i TEST STARTED 06/01/2010 f+ BEGIN LEVEL 4,5531 IN END TIME 3:45 PM END DATE 06/01/2010 END LEVEL 4,5519 IN LEAK THRESHOLD 0,002 IN TEST RESULT PASSED JL ' r► Tanknology 11000 N. MoPac Expressway,Suite 500 Austin,Texas 78759 Phone: (512)451-6334 Fax: (512)459-1459 Date Printed and Mailed: 07/09/2010 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR CRAIG PERKINS 1501 TRUXTUN AVE. BAKERSFIELD, CA. 93301 Test Date: 07/01/2010 Order Number: 2275545 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: VALERO 3074 3225 BUCK OWENS BLVD. HWY 99/HWY 58 BAKERSFIELD, CA. 93301 Testing performed: Impact Valve Leak detector tests Line tests Monitor Certification Sincerely, o KA Dawn Kohlmeyer Manager, Field Reporting 7� TANKNOLOGY CERTIFICATE OF TESTING � �p/1kQX)kV,/ 8501 N.MOPAC EXPRESSWAY#400,AUSTIN,TEXAS 78759 TELEPHONE(512)451-6334 FAX(512)459-1459 PURPOSE: COMPLIANCE TEST RESULT SUMMARY REPORT WORK ORDER NUMBER: 2275545 TEST DATE: 07/01/10 CUSTOMER PO: CLIENT: VALERO SITE:VALERO 3074 685 W THIRD ST 3225 BUCK OWENS BLVD. HANFORD,CA 93230 HWY 99/HWY 58 BAKERSFIELD,CA 93301 SANDY HUFF MANAGER-JOEL (559)583-3298 (661)324-9481 WIN / 'Tank Ti htnessTests Results TEST TYPE: NONE j p Te , k? f 'S+' Pf6ESII UU,T; (T R� Wir Pl bd D3{'aT$ = Sf 43ar k 3Hwp' �1 ER � ^n j& S1K u � sas 87 UNLEADED 14,130 95.00 DW STEEL 91 PREMIUM 10,140 95.00 DW STEEL 20k DIESEL 20,068 129.0 DW STEEL SATTELITES DIESEL 1 1.00 DW STEEL *Where regulations require,for VacuTect external water level may be depth of dry well or water is assumed at lowest point that can be confirmed dry. Product Pi a Ti htness Test Results M[ NMST 0 Cm it L > ( )EHO ►� V � 87 3 DW FIBERG PRESSURE P 0.006 TLD-1 Y 91 4 DW FIBERG PRESSURE P 0.006 TLD-1 Y 20k 6 DW FIBERG PRESSURE P 0.000 TLD-1 Y SATTELIT8 Y Existinq Line Leak Detector Test SOL- 11"N Af17 SE RE P G ER: SU N 87 3 RED JACKET FX1V 205083195 P 91 4 RED JACKET FX1V 32089410 P 20k 6 RED JACKET FX1—DV 406099485 P SATTELIT8 New Replacement Line Leak Detector Test am - 14 AN Am For owner detailed report information,visit www.tanknology.com and select On-Line Reports-WRAP,or contact your local Tanknology office. Tester Name:JON ADAMS Technician Certification Number: Tester Signature: µn, 3 Date Signed: 7-/9-/6 1 declare under penalty of perjury that I am a licensed tank tester in the State of California and that the information contained in this report is true and correct to the best of my knowledge. INDIVIDUAL TANK INFORMATION AND TEST RESULTS 11110 Tan TEST DATE: 07/01/10 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER: 2275545 AUSTIN,TEXAS 78759(512)451-6334 CLIENT: VALERO SITE: VALERO 3074 r�NK tl N RW ATl - Tank ID: 87 3 Tank manifolded: NO Bottom to top fill in inches: 140.5 Product: UNLEADED Vent manifolded: YES Bottom to grade in inches: 145.0 Capacity in gallons: 14,130 Vapor recovery manifolded: YES Fill pipe length in inches: 44.5 Diameter in inches: 95.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 Length in inches: 466 Overspill protection: YES Stage I vapor recovery: DUAL Material: Dw STEEL Installed: ATG Stage II vapor recovery: ASSIST CP installed on: COMMENTS MAN- RESULTS est Meth d:NONE DETE OR TEST RESULTS est method: PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 UFT/OFT: Make: RED JACKET Fluid volume in gallons: Model: Fx1V Tank water level in inches: S/N: 205083195 Test time: NOT Open time in sec: 3.00 Number of thermisters: TESTED Holding psi: 10 NOT Specific gravity: Resiliency cc: 70 TESTED Water table depth in inches: Test leak rate ml/m: 189.0 Determined by(method): Metering psi: ' 12 Leak rate in gph: Calib. leak in gph: 3.00 Result: Results: PASS COMMENTS COMMENTS ULLA E TES RESUL es Metho :NONE lfl E EST RESU"TS Test time: Ullage volume: Material: Dw FIBERG Ullage pressure: Diameter(in): 2.0 Results: Length (ft): 100.0 Test psi: 50 DATA FOR UTS-4T ONLY: Bleedback cc: 2 Time of test 1: Test time(min): 30 Temperature: NOT Start time: 10:00 NOT NOT NOT Flow rate(cfh): TESTED End time: 10:30 TESTED TESTED TESTED Time of test 2: Final gph: 0.006 Temperature: Result: PASS Flow rate(cfh): Pump type: PRESSURE Time of test 3: Pump make: RED JACKET Temperature: Flow rate(cfh): Impact Valves Operational: YES COMMENTS COMMENTS Printed 07/09/2010 08:14 ACRAMER INDIVIDUAL TANK INFORMATION AND TEST RESULTS ►Tanknology TEST DATE: 07/01/10 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER: 2275545 AUSTIN,TEXAS 78759(512)451-6334 CLIENT: VALERO SITE: VALERO 3074 TAWK IN ORMA 'ON Tank ID: 91 4 Tank manifolded: No Bottom to top fill in inches: 138.5 Product: PREMIUM Vent manifolded: YES Bottom to grade in inches: 145.0 Capacity in gallons: 10,140 Vapor recovery manifolded: YES Fill pipe length in inches: 42.5 Diameter in inches: 95.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 Length in inches: 334 Overspill protection: YES Stage I vapor recovery: DUAL Material: Dw STEEL Installed: ATG Stage II vapor recovery: ASSIST CP installed on: COMMENTS TANK RESU T est Metho .No LE UETECTO TEST RESULTS T method: PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 UFT/OFT: Make: RED JACKET Fluid volume in gallons: Model: Fx1V Tank water level in inches: S/N: 32089410 Test time: NOT Open time in sec: 3.00 Number of therrnisters: TESTED Holding psi: 14 NOT Specific gravity: Resiliency cc: 90 TESTED Water table depth in inches: Test leak rate ml/m: 189.0 Determined by(method): Metering psi: 12 Leak rate in gph: Calib. leak in gph: 3.00 Result: Results: PASS COMMENTS COMMENTS UCLA E TEST IJPS&5@vm 111111&TE T RESU STS Test type: Test time: Ullage volume: Material: Dw FIBERG Ullage pressure: Diameter(in): 2.0 Results: Length (ft): 100.0 Test psi: 5o DATA FOR UTS-4T ONLY: Bleedback cc: 5 Time of test 1: Test time(min): 30 Temperature: NOT Start time: 10:00 NOT NOT NOT Flow rate(cfh): TESTED End time: 10:30 TESTED TESTED TESTED Time of test 2: Final gph: 0.006 Temperature: Result: PASS Flow rate(cfh): Pump type: PRESSURE Time of test 3: Pump make: RED JACKET Temperature: Flow rate(cfh): Impact Valves Operational: YES COMMENTS COMMENTS IL Printed 07/09/2010 08:14 ACRAMER INDIVIDUAL TANK INFORMATION AND TEST RESULTS J'P TarnlvWiogy TEST DATE: 07/01/10 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER: 2275545 AUSTIN,TEXAS 78759(512)451-6334 CLIENT: VALERO SITE: VALERO 3074 MOMP—M—WINF CIRM'A_`TiI:ON Tank ID: 20k 6 Tank manifolded: No Bottom to top fill in inches: 193.0 Product: DIESEL Vent manifolded: NO Bottom to grade in inches: 201.0 Capacity in gallons: 20,068 Vapor recovery manifolded: No Fill pipe length in inches: 64.0 Diameter in inches: 129.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 Length in inches: 358 Overspill protection: YES Stage I vapor recovery: NONE Material: DW STEEL Installed: ATG Stage II vapor recovery: NONE CP installed on: COMMENTS Lines b, c, d and a & b form tank #8are all stilite lines. TANK -S-1WREN&TSAMMMU IN L U ME RN T RESUL es method: PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 LIFT/OFT: Make: RED JACKET Fluid volume in gallons: Model: FX1-DV Tank water level in inches: S/N: 406099485 Test time: NOT Open time in sec: 3.00 Number of thermisters: TESTED Holding psi: 40 NOT Specific gravity: Resiliency cc: 180 TESTED Water table depth in inches: Test leak rate ml/m: 189.0 Determined by(method): Metering psi: 11 Leak rate in gph: Calib. leak in gph: 3.00 Result: Results: PASS COMMENTS COMMENTS ULLAG TEST RESULTS est Method: ores LINE TEST RESUL T6 type. TLD 1 Test time: Ullage volume: Material: DW FIBERG DW FIBERG DW FIBERG DW FIBERG Ullage pressure: Diameter(in): 3.0 2.0 2.0 2.0 Results: Length(ft): 220.0 20.0 20.0 20.0 Test psi: 5o DATA FOR UTS-4T ONLY: Bleedback cc: 1 Time of test 1: Test time(min): 30 Temperature: NOT Start time: 12:00 NOT NOT NOT Flow rate(cfh): TESTED End time: 12:30 TESTED TESTED TESTED Time of test 2: Final gph: 0.000 Temperature: Result: PASS Flow rate (cfh): Pump type: PRESSURE NONE NONE NONE Time of test 3: Pump make: RED JACKET NONE NONE NONE Temperature: Flow rate(cfh): Impact Valves Operational: YES COMMENTS COMMENTS J Printed 07/09/2010 08:14 ACRAMER