Loading...
HomeMy WebLinkAboutFMC RESULTS 9-3-08 MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoriniz system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems \. within 30 days of this date. I IIIIIII VIII III IIII 61 A. General Information Facility Name: Big Country Texaco IE Bldg.No.: Site Address: 6009 Coffee Road City: Bakersfield zip: Facility Contact Person: James Young Contact Phone No.: 661-327-5008 Make/Model of Monitoring System: Veeder-Root TLS-350 Date of Testing/Servicing: 9/3/2008 S B. Inventory of Equipment Tested/Certified -A Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID: 12000 gal.Regular Tank ID: 12000 gal.Super [X] In-Tank Gauging Probe. Model:847390-107 [x] In-Tank Gauging Probe. Model:847390-107 [x] Annular Space or Vault Probe. Model:794390-409 [x] Annular Space or Vault Sensor. Model: 794390-409 [x] Piping Sump/Trench Sensor(s). Model:794380-208 [x] Piping Sump/Trench Sensor(s). Model: 794380-208 [x] Fill Sump Sensor(s) Model:794380-208 (x] Fill Sump Sensor(s). Model:794380-208 U Mechanical Line Leak Detector. Model:FX1y [x] Mechanical Line Leak Detector. Model: FX1y ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: [X] Tank Overfill/High Level Sensor. Model:847390-107 Lx] Tank Overfill/High Leval Sensor. Model: 847390-107 ❑ Other(specify equip.type and model in Sec. E on Pg.2) ❑ Other(specify equip.type and model in Sec. E on Pg.2) Tank ID: 12000 gal.Diesel Tank ID: [x] In-Tank Gauging Probe. Model:.847390-107 ❑ In-Tank Gauging Probe. Model: [x] Annular Space or Vault Sensor. Mode 1:794390.409 ❑ Annular Space or Vault Sensor. Model: [x] Piping Sump/Trench Sensor(s). Model:794380-208 ❑ Piping Sump/Trench Sensor(s). Model: [x] Fill Sump Sensors(s). Model:794380-208 ❑ Fill Sump Sensor(s). Model: [x] Mechanical Line Leak Detector. Model:FX1DV ❑ Mechanical Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: [x] Tank Overfill/High Level Sensor. Model:847390-107 ❑ Tank Overfill/High Level Sensor.Model: ❑ Other(specify equip.type and model in Sec. E on Pg.2) ❑ Other(specify equip.typs and model in Sec. E on Pg. 2) Dispenser ID: 1 &2 Dispenser ID: 3&4 n Dispenser Containment Sensor(s). Model: 4201208 [X] Dispenser Containment Sensor(s). Model: 4201208 E] Shear Valve(s). U Shear Valve(s). ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s) Dispenser ID: 5&6 Dispenser ID: 7&8 [x] Dispenser Containment Sensor(s). Model: 420/208 (� Dispenser Containment Sensor(s). Model: 4201208 [x] Shear Valve(s). U Shear Valve(s). ❑ Dispenser Containment Float(s)and Chains(s). ❑ Dispenser Containment Float(s)and Chain(s). Dispenser ID: 9&10 Dispenser ID: 11 &12 [x] Dispenser Containment Sensor(s). Model: 420/208 [x] Dispenser Containment Sensor(s). Model: 4201208 [X] Shear Valve(s). L] Shear Valve(s). ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s). *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. C. Certification -I certify that the equipment identified in this document was inspected/services in accordance with the manufacturers'guidlines.Attached to this Certification is information(e.g.manufacturers'checklist)necessary to varify that this information is correct and a plot plan showing the layout of monitoring equipment. For eq ipment c of generating such reports,1 have attached a copy of the report; (check all that apply) ❑System S t- p Alarm history report Technician Name(print): Matthew Jennings Signature: Certification No: 835445 License No:804904 Testing Company Name: Confidence UST Services,Inc. Phone No: 80Y-339-9930 Site Address: 6009 Coffee Road,Bakersfield,CA IIIIIIIIIIIIIIIIIIII _Date of Testing/Servicing: 9/3/2008 62 IE D. Results of Testing/Servicing Software Version Installed: 325.02 Complete the following checklist: [x] Yes ❑ No* Is the audible alarm operational? x Yes No* Is the Visual alarm operational? x Yes No* Were all sensors visually inspected,functionally tested,and confirmed operational? x Yes ❑ No* Were all sensors installed at the lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) Hx N/A operational? x Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary ❑N/A containment monitoring system detects a leak,fails to operate, or is electrically disconnected? If yes: which sensors initate positive shut-down? E Sump/Trench Sensors Dispenser Containment Sensors Did you confirm positive shut-down due to leaks and sensor failure/disconnected? [X] Yes; ❑ No; I_I Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no ❑N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visual and audible at the tank fill point(s)and operating properly?If so,at what percent of tank capasity does the alarm trigger? 90 % Yes* ❑ No Was any monitoring equipment replaced? If Yes, identify specific sensors,probes,or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E,below. ❑ Yes* u No Was liquid found inside any secondary containment systems designed as dry systems? ❑ Product; ❑ Water. If yes, describe causes in Section E,below. DI No* I Was monitoring system set-up reviewed to ensure proper settings?Attach set-up reports, if applicable. Lxj Yes 1 0 No* I Is all monitoring equipment operational per manufacturer's specifications? * In Section E below,discribe how and when these deficiencies were or will be corrected. E. Comments: The 208 sensor in the Regular STP was replaced and retested. The vent box located @ the vent line has two sensors.A 420 and a 208. Both were accurately tested and passed F. In-Tank Guaging/SIR Equipment: M Check this box if tank guaging is used only for inventory control. ❑ Check this box if tank guaging or SIR equipment is installed. This section must be completed if in-tank guaging equipment is used to perform leak detection monitoring. Complete the following checklist: U Yes ❑ No* Has all input wiring been inspected for proper enter and termination,including testing for ground faults? _Tx3 Yes No* Were all tank guaging probes visually inspected for damage and residue buildup? x Yes D No* Was accuracy of system product level readings tested? x Yes No* Was accuracy of system water level readings tested? _[xl Yes No* Were all probes reinstalled properly? Lx] Yes ❑ No*I Were all items on the equipment manufacturer's maintenance checklist completed? * In the Section H,below,describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): ❑Check this box if LLD's are not installed. Complete the following checklist: [x� Yes ❑ No* For equip. start-up or annual equipment certification,was a leak simulated to varify LLD performance? (Check all that apply) Simulated leak rate: ❑3 g.p.h.: 00.1 g.p.h.; ❑0.2 g.p.h.; x Yes No* Were all LLD's confirmed operational and accurate within regulatory requirments? x Yes 7 No Was the testing apparatus properly calibrated? r] Yes No* For machanical LLD's, does the LLD restrict product flow if it detects a leak? N/A F-1 Yes No* For electronic LLD's,does the turbine automatically shut off if the LLD detects a leak? Lx] N/A ❑ Yes No* For electronic LLD's,does the turbine automatically shut off if any portion of the monitoring system is [x] N/A disabled or disconnected? ❑ Yes No* For electronic LLD's,does the turbine automatically shut off if any portion of the monitoring system Lx] N/A malfunction or fails a test? ❑ Yes D No* For electronic LLD's,have all accessible wiring connections been visually inspected? Lx] N/A FUx Yes No I Were all items on the equipment manufacturer's maintenance checklist completed? * In the section H,below,describe how and when these deficiencies were or will be corrected. H. Comments: Monitoring Systen Certification Form:Addendum for Vacuum/Pressure Interstitial Sensors LG 163-1,Enc.11 I. Results of Vacuum/Pressure Monitoring Equipment Testing This page should be used to document testing and servicing of vacuum and pressure interstitial sensors. A copy of this form must be included with the Monitoring System Certification Form,which must be provided to the tank system owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the local agency regulating UST systems within 30 days of the test date. Manufacturer: Model: F— System type: ❑ Pressure; ❑Vacuum; Sensor ID Component(s)Monitored by this Sensor:�UN PRODU CT s-1 Sensor Funtionali Test Results X Pass Interstitial Communication Test Results: X Pass Fail Component(s)Monitored by this Sensor: [�Fail VAPOR LINE S-2 Sensor Funtionality Test Results:X Pass Fail Interstitial Communication Test Results: X ass; I I Fail Component(s)Monitored by this Sensor: UNL VENT LINE s-3 Sensor Funtionality Test Results: X Pass Fail Interstitial Communication Test Results: X ass; I IFail Component(s)Monitored by this Sensor: PRM PRODUCT s-4 Sensor Funtionality Test Results: Pass X Fail Interstitial Communication Test Results: ass; X Fail Component(s)Monitored by this sensor: PRM VENT s-5 Sensor Funtionality Test Results ix]Pass I Fail Interstitial Communication Test Results: ass; I Vail Component(s)Monitored by this Sensor: DIESEL PRODUCT s-6 Sensor Funtionality Test Results: X Pass Fail Interstitial Communication Test Results: X ass; I IFail Component(s)Monitored by this Sensor: DIESEL VENT s-7 Sensor Funtionality Test Results• X Pass Fail Interstitial Communication Test Results: IxFas s; Fail Component(s)Monitored by this Sensor: Sensor Funtionality Test Results Pass Fail Interstitial Communication Test Results: ass;I Vail Component(s)Monitored by this Sensor: Sensor Funtionality Test Resultsn Pass Fail Interstitial Communication Test Results: I ass; Fail Component(s)Monitored by this Sensor: Sensor Funtionality Test Results: Pass Fail Interstitial Communication Test Results: ass; ail Component(s)Monitored by this Sensor: Sensor Funtionality Test Results: Pass Fail Interstitial Communication Test Results: ass; Fail How was interstitial communication varifyed? [X—j Leak Introduced at Far End of Interstitial Space; Gauge; X Visual Inspection; Othe Discribe in Sec.J, below Vacuum was restored to operating levels in all interstitial spaces: ❑ Yes X❑ No(1f no, discribe in Sec.J Below) Comments: S-4 was in alarm upon arrival . The sensor was tested, but was unable to hold a vaccum. Page 4 of 4 If the sensor successfully detected a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the sensor,vacuum/pressure has been demonstrated to be communicating throughout the interstice. SYSTEM SETUP - COMMUNICATIONS SETUP BIG C:OUl'JTR'Y TEXACO - - - - - - - - - - - - - - - - - - - - - - - - ' 6009 COFFEE RD. SEP 3, 2008 6:50 AM BAKERSFIELD,CA 93308 PORT SETT I NGS: SEP 3. 2008 8:50 Ahi SYSTEM UNITS COMM BOARD 2 t FX.MOD) U.S. BAUD RATE 2400 SYSTEM LANGUAGE PARITY : ODD ENGLISH STOP BIT : I STOP S`Y'STEM STHTU a REPORT S,S TEM CITE: T 1 P9E FvkMAT DATA LENGTH: 7 DATA PION LSD YY'.Y HH:Nll°l:SS : l-1 RS-232 SECURITY s 4:140 VACUUM ALARM CODE : DISABLED BIG COUNTRY TEXACO DIAL TYPE : TONE 6009 COFFEE RD. ANSWER ON i RING INVENTORY REPORT BAKERSFIELD.CA 93306 MODEM SETUP STRING DIAL TONE INTERVAL: 3'2 T 1 :UNLEADED SHIFT TIME 1 DISABLED VOLUME = 9105 GALS SHIFT TIME 2 : DISABLED ULLAGE = _2895 GALS SHIFT TIME 3 DISABLED RECEIVER SETUP: 904. ULLAGE= 1695 GALS SHIFT TIME 4 DISABLED TC VOLUME = 8970 GALS NONE HEIGHT = 68.12 INCHES TANK PER TST NEEDED WR1V WATER VOL = 0 GALS DISABLED WATER = 0.00 INCHES TANK ANN TST NEEDED WRhI TEMP = 81 .1 DEC F DISABLED LINE RE-ENABLE METHOD T 2:PREMIUPI PASS LINE TEST VOLUME = 2932 GALS ULLAGE 9068 GALS LINE PER TST NEEDED NEEDED l 1RhJ 90% ULLAGE= 7866 GALS DISABLED TC VOLUME = 2677 GALS LINE ANN TST NEEDED WRN HEIGHT = 28.14 INCHES DISABLED AUTO DIAL TIME SETUP: WATER VOL = 0 GALS PRINT TC VOLUMES NONE WATER = 0.00 I NCFIES � ENABLED = 86.3 DEC F TEMP i�OMPENSAT ION T 3:DIESEL VALUE (DEC F ) : 60.0 VOLUME = 3631 GALS STICK HEIGHT OFFSET ULLAGE = 8369 GALS' DISABLED 90% ULLAGE= 7169 GALS TC VOLUME = 3576 GALS H-PROTOCOL DATA FORMAT HEIGHT = 32.66 INCHES HEIGHT- WATER VOL = 0 GALS DAYLIGHT SAVING TIME WATER = 0.00 INCHES ENABLED TEMP = 93.2 DEG F START DATE MAR WEEK 1 SUN START TIME * = END 2:00 All DISABLED OF MESSAGE END DATE OCT WEEK 6 SUN END TIME AUTO DIAL ALARM SETUP 2:00 AM - - - - - - - - - - - - RE-DIRECT LOCAL PRINTOUT DISABLED EURO PROTOCOL PREFIX S SYSTEM SECURITY CODE : 000000 CUSTOM ALARM LABELS DISABLED IN—TANK SETUP T 2:PRElllIUM T 3:D}ESEL — — — — — — — — — — — — PRODUCT CODE 2 PRODUCT CODE 3 THERMAL COEFF : .000700 THERMAL COEFF : .000450 T 1 :UNLEADED TANK DIAMETER 96.00 TANK DIAMETER 98.00 PRODUCT CODE I TANK PROFILE I PT TANK PROFILE 1 PT THERMAL COEFF : .000700 FULL VOL 12000 FULL VOL 12000 TANK DIAMETER 98.00 TAPdK; PROFILE 1 PT FULL VOL 12000 FLOAT SIZE: 4.0 IN. FLOAT SIZE: 4.0 IN. WATER WARNING : 2.0 WATER WARNING 2.0 FLOAT ;SIZE: 4.0 IN. HIGH WATER LIMIT: 3.0 HIGH WATER LIMIT: 3.0 WATER 1AARNING 2.0 MAX OR LABEL VOL: 12000 MAX OR LABEL 'VOL: 12000 HIGH WATER LIMIT: 3.0 OVERFILL LIMIT 90% OVERFILL LIMIT 90% 10800 10800 MAX OR LABEL VOL: 12000 HIGH PRODUCT 95% HIGH PRODUCT 95% OVERFILL LIMIT 90% 11400 11400 10800 DELIVERY LIMIT 15% DELIVERY LIMIT 15% HIGH PRODUCT 95% 1800 1800 11400 DEL I VER`! L I I°1 I T 15% LOW PROIiUCT 1000 LOW PRODUCT 1000 1800 LEAK ALARM LIMIT: 99 LEAK; ALARM LIMIT: 99 SUDDEN LOSS LIMIT: 99 SUDDEN LOSS LIMIT: 99 LOW PRODUCT 1000 TA14K TILT 0.00 TANK TILT 0.00 LEAK: ALARM LIMIT: 99 PROBE OFFSET 0.00 PROBE OFFSET 0.00 SUDDEN LOSS LIMIT: 99 TANK TILT 0.00 PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS SIPHON PIANIFOLDED TANKS TO: NONE T#: NONE LINE NIANIFOLDED TANKS LINE MANIFOLDED TANKS SIPHON MANIFOLDED TANKS T#: NONE TO' NONE TO: NONE LINE MANIFOLDED TANKS TO: NONE LEAK MIN PERIODIC: 1% LEAK MIN PERIODIC: 1 120 120 LEAK 1111--1 PERIODIC: 1% LEAK MIN ANNUAL I LEAV. MIN ANNUAL 1% 120 120 120 LEAK: M111 ANNUAL 1% 120 PERIODIC: TEST TYPE PERIODIC TEST TYPE STANDARD _ STANDARD PERIODIC TEST TYPE ANNUAL TEST FAIL ANNUAL TEST FAIL STANDARD ALARM DISABLED ALARM DISABLED ANNUAL TEST FAIL PERIODIC TEST FAIL PERIODIC: TEST FAIL ALARM DISABLED ALARM DISABLED ALARM DISABLED PERIODIC TEST FAIL GROSS TEST FAIL GROSS.; TEST FAIL ALARM DISABLED ALARM DISABLED ALARM DISABLED GROSS TEST FAIL ANN TEST AVERAGING: OFF ANN TEST AVERAGING: OFF ALARM DISABLED PER TEST AVERAGING: OFF PER TEST AVERAGING: OFF ANN TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TANK TEST NOTIFY: OFF PER TEST AVERAGING: OFF TAP}}t TEST NOTIFY: OFF TNY•. TST SIPHON BREAK:OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY I MIN DELIVERY DELAY 1 MIN TNK TST SIPHON BREAK:OFF PUMP THRESHOLD 10.00% PUMP THRESHOLD 10.00 DELIVERY DELAY 1 MIN PUMP THRESHOLD 10.00" LEAK TEST METHOD - - - - - L11 :DIESEL STP SUMP L25DISP 7-6 2 TEST ON DATE : ALL TANK : 2ND TRI-STATE (SINGLE FLOAT) LORI CLOSED ALLY CLO JAN 15, 2007 CATEGORY : STP SUMP CATEGORY OTHER SENSORS START TIME : 2:00 Art TEST RATE :0.20 GAL/HR DURATION 2 HOURS L12:DIESEL FILL SUMP 2ND NOWIALLY CLOSED L26:D I SP 9-10 TST EARLY STOP:DISABLED CATEGORY : OTHER SENSORS TRI-STATE (SINGLE FLOAT) LEAK TEST REPORT FORMAT CATEGORY : DISPENSER PAN NORMAL L13:DIESEL FILL SUMP TRI-STATE (SINGLE FLOAT) L27:DISP 9-10 2ND CATEGORY : OTHER SENSORS NdR11ALLY CLO,yED CATEGORY : OTHER SENSORS L14:DIESEL FILL SUMP 219D NORMALLY CLOSED L28:DISP 11-12 CATEGORY OTHER SENSORS TRI-STATE (SINGLE FLOAT) CATEGORY : DISPENSER P'A14 LIQUID SENSOR SETUP - - - - - - - - - - - - L15:DIESEL ANNULAR DUAL POINT HYDROSTATIC L29:DISP 11-12 2ND L 1 :U�IL STP SUMP, CATEGORY : ANNULAR SPACE IVdkt1ALL1' CLOSED CATEGORY STP SUMP STATE (SINGLE FLOAT; CATEGORY : OTHER SENSORS G'A LI6'- ENT BOX, L 2:UNL STP SUMP 2ND TRI-STATE tS1NGLE FLOAT) NORMALLY CLOSED CATEGORY : OTHER SENSORS CATEGORY : OTHER SENSORS L17:VENT BOX 2ND L 3:UNL FILL SUMP TRI-STATE (SINGLE FLOAT) TRI-STATE (SINGLE FLOAT) CATEGORY : OTHER SENSORS CATEGORY : OTHER SENSORS PUMP SENSOR SETUP L1S:DISP 1-2 _ L 4:UNL FILL SUMP 214D TRI-STATE (SINGLE FLOAT) - - - - - - - - - - NORMALLY CLOSED CATEGORY : DISPENSER PAN S I :UNLEADED CATEGORY OTHER SENSORS TANK #: I DISPENSE MODE: L19:DISF' 1-2 211U STANDARD L S:UNL ANNULAR NORMALLY CLOSED S 2:PREMIUM DUAL POINT HYDROSTATIC CATEGORY : OTHER SE14SORS TALK U: 2 CATEGORY : ANNULAR SPACE DISPENSE MODE: STANDARD L20:DISP 3-4 S 3:DIESEL L 6:PREM STP SUMP TRI-STATE (SINGLE FLOAT) TANK it: 3 TRI-STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN DISPENSE MODE: CATEGORY : STP SUMP STANDARD , L 7:PREM STP SUMP 2ND L21 :DISP 3-4 2ND NORMALLY CLOSED NORMALLY CLOSED CATEGORY : OTHER SENSOR' CATEGORY : OTHER SENSORS L 8:PREM FILL SUMP L22:DISP 5-6 TRI-STATE (SINGLE FLOAT) TRI-STATE (SINGLE FLOAT) CATEGORY : OTHER SENSORS CATEGORY : DISPENSER PAN L 9:PREM FILL SUMP 2ND L23:DISP 5-6 2ND NORMALLY CLOSED NORMALLY CLOSED CATEGORY : OTHER SENSORS CATEGORY : OTHER SENSORS L10:PREM ANNULAR L24:DISP 7-8 DUAL POINT HYDROSTATIC TRI-STATE (SINGLE FLOAT') CATEGORY : ANNULAR SPACE CATEGORY DISPENSER PAN R 3:DIESEL SMARTSENSOR SETUP TYPE: OUTPUT RELAY SETUP _ - _ - - - - _ _ _ - - PUMP CONTROL OUTPUT - - - - - - - - - - - - TANK #: 3 s 1 :UNL PRODUCT R 1 :UNLEADED CATEGORY VAC SENSOR TYPE: PUMP #: IN-TANY ALARM: PUMP CONTROL OUTPUT R 1 :UNLEADED T 3:LEAK ALARM TANK #: 1 VOLUME: 200.0 GALLONS RELIEF VALVE: : NO LIQUID SENSOR ALMS L11 :FUEL ALARM IN-TANK ALARMS 5 2:VAPOR LINE L18:FUEL ALARM T '. :LEAK ALARM CATEGORY VA+_: SENSOR L20:FUEL ALARM PUMP #: L22:FUEL ALARM LIQUID SENSOR ALMS R 1 :UNLEADED L24:FUEL ALARM L 1 :FUEL ALARM VOLUME: 175.0 GALLONS L26:FUEL ALARM L 6:FUEL ALARM RELIEF VALVE: : NO L28:FUEL ALARM LIB:FUEL ALARM L1l :SENSOR OUT ALARM L20:FUEL ALARM s 3:UNL VENT L18:SENSOR OUT ALARM L22:FUEL ALARM CATEGORY VAC: SENSOR L20:SENSOR OUT ALARM L24:FUEL ALARM PU11P #: L22:SENSOR OUT ALARM L26:FUEL ALARM R 1 :UNLEADED L24:SENSOR OUT ALARM L28:FUEL ALARM VOLUME: 20.0 GALLONS L26:SENSOR OUT ALARM L I :SENSOR OUT ALARM RELIEF VALVE: : NO L28:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L11 :SHORT ALARM LIB:SENSOR OUT ALARM s 4:PREMIUM PRODUCT L18:SHORT ALARM L20 2ENSOR OUT ALARM CATEGORY VAC SENSOR L20:SHORT ALARM L22:SENSOR OUT ALARM PUMP #: L22:SHORT ALARM L242ENSOR OUT ALARM R 2:PREMIUM L24:SHORT ALARM L26:SENSOR OUT ALARM VOLUME: 200.0 GALLONS L26:SHORT ALARM L28:SENSOR OUT ALARM RELIEF VALVE: : NO L26:SHORT ALARM L 1 :SHORT ALARM L 6:SHORT ALARM s 5:PREMIUM VENT R 4:OUERFILL L18:SHORT ALARM CATEGORY VAC SENSOR TYPE: L20:SHORT ALARM PUMP #: STANDARD L22:SHORT ALARM R 2:PREJMIUM NORMALLY OPEN L24:SHORT ALARM VOLUME: 20.0 GALLONS L26:SHORT ALARM RELIEF VALVE: : NO L28:SHORT ALARM IN-TANK ALARMS s 6:DIES:EL PRODUCT ALL:OVERFILL ALARM R 2:PREIMIUIM CATEGORY VAC SENSOR ALL:HIGH PRODUCT ALARM TYPE: PUMP #: ALL:MAX PRODUCT ALARM PUMP CONTROL OUTPUT R 3:DIESEL TANK #: 2 VOLUME: 200.0 GALLONS RELIEF VALVE: : NO IN-THNK ALARMS s 7:DIESEL VENT T 2:LEAK ALARM CATEGORY VAC SENSOR PUMP #: LIQUID SENSOR ALMS R 3:DIESEL L I :FUEL ALARM VOLUME: 40.0 GALLONS L 6:FUEL ALARM RELIEF VALVE: : NO L18:FUEL ALARM L20:FUEL ALARM s B:ATM L2 2:FUEL ALARM CATEGORY ATM P SENSOR L24:FUEL ALARM L26:FUEL ALARM L28:FUEL ALARM L 1 :SENSOR OUT ALARM L 6:SENSOR OUT ALARM L18:SENSOR OUT ALARM L20:SENSOR OUT ALARM L22:SENSOR OUT ALARM L24:SENSOR OUT ALARM L26:SENSOR OUT ALARM L28:SENS0R OUT ALARM L 1 :SHORT ALARM SOFTWARE REVISION LEVEL L 6:SHORT ALARM VERSION 325.02 L1B:SHORT ALARM SOFTWARE# 346325-100-C L20:SHORT ALARM CREATED - 05.08.09. 12.51 L22:SHORT ALARM L24:SHORT ALARM NO SOFTWARE (MODULE L26:SHORT ALARM SYSTEM FEATURES: L26:SHORT ALARM PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ` ALARM HISTORY REPORT ALARM HISTORY REPORT ALARM HISTORY REPORT ----- SENSOR ALARM ----- ----- SENSOR ALARM ----- L S:UNL ANNULAR ---- IN-TANK ALARM ----- L 2:UNL STP SUMP 2ND ANNULAR SPACE OTHER SENSORS LOW LI(JU1D ALARM T I :UNLEADED FUEL ALARM AUG 17, 2007 1 : 10 Phi AUG 17. 2007 2:00 PM OVERFILL ALARM LOW LIQUID ALARM AUG 28, 2008 1'-2:54 AM FUEL ALARM MAR 6, 2006 1 :52 PM MAY 31 , 2008 11 :05 PM SEP 29, 2006 8: 13 AM MAY 24. 2008 2: 14 AM HIGH LIQUID ALARM FUEL ALARM MAR 6. 2006 1 :38 Pill LOW PRODUCT ALARM SEP 26, 2006 2:56 PM AUG 5. 2008 6: 18 PM JUL 12,, 2008 8:34 AM DEC 24, 2007 2:29 Phi HIGH PRODUCT ALARM MAY 31 , 2008 11 :06 PM .IAN 14. 2007 3:37 PM DEC 17. 2006 11 :01 AM INVALID FUEL LEVEL ri r M ri ri END AE dE JUL 12. 2008 10: 10 AM * x END * n DEC 24, 2007 3:27 Phi AUG 27, 2007 8:31 PM PROBE OUT JAN 28, 2008 12:50 AM JAN 28, 2008 12:45 AM JAN 28, 2008 12:23 AM DELIVERY NEEDED SEP 1 , 2008 2:09 All ALARM HISTORY REPORT AUG 29. 2008 5:46 PM ALARM HISTORY REPORT AUG 25. 2008 8:18 Pill ----- SENSOR ALARM ----- -- SENSOR ALARM ----- L G:PREM STP SUMP MAX PRODUCT ALARM L 3:UNL FILL SUMP STP SUMP JAN 14. 2007 3:37 Pil OTHER SENSORS FUEL ALARM JUN 17, 2006 4:49 AM FUEL ALARM AUG 17.. 2007 2:13 PM JUN 12, 2006 6:14 All AUG 17, 2007 5:31 PM SENSOR OUT ALARM FUEL ALARM LOW TEMP WARNING AUG 17. 2007 5:22 PM MAR 6. 2006 1 :26 Pill MAR 6, 2006 2:15 PM FUEL ALARM FUEL ALARM MAR 4, 2006 11 :43 AM AUG 17, 2007 4:56 Pi°1 ri * n n END x x ri ri x h i i X END * * END ii ii if i ALARM HISTORY REPORT ----- SENSOR ALARM ----- ALARM HISTORY REPORT ALARM HISTORY REPORT L 1 :UNL STP SUMP ----- SENSOR ALARM ----- STP SUMP ----- SENSOR ,:ARhi ----- L 7:PREM STP SUMP 2ND FUEL ALARM L 4:UNL FILL SUMP 2ND OTHER SENSORS AUG 17. 2007 2:12 Phi OTHER SENSORS. SENSOR OUT ALARM FUEL ALARM MAY 30, 2008 7:26 PM FUEL ALARM AUG 17, 2007 1 :54 PM AUG 17. 2007 2:08 PM SENSOR OUT ALARM FUEL ALARM MAY 30. 2008 7:21 PM FUEL ALARM MAR 6, 2006 1 :42 PM MAR 6, 2006 1 :35 PM SENSOR OUT ALARM MAY 30. 2008 4:30 PM ALARM HISTORY REPORT ALARM HISTOR': ALARM HISTORY REPORT ALARM HISTORY REPORT ALARM HISTORY REPORT ----- SENSOR ALARM ----- SENSOR ALARM ----- ----- SENSOR ALARM ----- L23:D I SP 5-6 21VU L17:VENT BOX 2ND L20:DISP 3-4 OTHER SENSORS OTHER SENSORS DISPENSER PAN FUEL ALARM FUEL ALARM FUEL ALARM AUG 17, 2007 3:52 PM AUG 17, 2007 3:38 PM DEC 8, x'007 7:32 All FUEL ALARM FUEL ALARM FUEL ALARM SEF 5. 2007 4: 10 All MAY 25, 2007 10:40 AM MAR 6, 2006 1 :33 PM SENSOR OUT ALARM FUEL ALARM FUEL ALARM AUG 17, 2007 2: 19 PI°i MAY 25. 2007 10:31 All AUG 9, 2005 8:48 AM ?i END n 3F # E ri '* f x ri END x t 3E h * END n ri ri ri ALARM HISTORY REPORT ALARM HISTORY REPORT ALARM HISTORY REPORT ----- SENSOR ALARM ----- ----- SENSOR ALARM ----- ----- SENSOR ALARM ----- LI8:DISP 1-2 L21 :DISP 3-4 2ND L25:DISP 7-8 2ND DISPENSER PAN OTHER S OTHER SENSORS ENSORS FUEL ALARM FUEL ALARM FUEL ALARM FUEL 12, 4:09 Pt°1 AUG 17, 2007 3:39 PM AUG,, 17. 2007 2:21 PN1 NOV FUEL ALARM FUEL ALARih FUEL ALARM MAR 6. 2006 1 :32 PH JAN - 9,. 2007 8:28 AM NOV 1'-2, 2007 4:09 PM FUEL ALARM FUEL ALARM FUEL ALARM NOV 12. 2007 4:03 PM AUG 9, 2005 8:48 AM JAN 9, 2007 8:06 AM iE ii i x END E ie 3E iE if x iE i iE n END ii { rx iE i rE ii a ii END ALARM HISTORY REPORT ALARM HISTOR`! REPORT ALARM HISTORY REPORT ----- SENSOR ALARM ----- `---- S SE ENSOR ALARM ----- - SENSOR ALARM L26:DISP 9-10 L19:DISP 1-2 2ND L22:DISP 5-6 DISPENSER PAN OTHER SENSORS DISPENSER PAN FUEL ALARM FUEL ALARM FUEL ALARM JUN 3, 2008 1 :35 PM AUG, 17, 2007 3:35 PM AUG 17. 2007 3:29 PM FUEL ALARM FUEL- ALARM FUEL ALARM MAR 6, =006 1 '35 Ph1 MAY 15, 2008 5: 16 AM AUG 17, 2007 3:33 PM - FUEL ALARM FUEL ALARM FUEL ALARM MAY 8, 2008 11 :22 AM IlAR 6, 2006 1 :34 PM AUG 9, 2005 8:47 AM ALARM HISTORY REPORT ALARM HISTORY REPORT ALARM HISTORY REPORT -- SMARTSENSOR ALARM -- --- SMARTSENSOR ALARM -- ----- SENOR ALARM ----- I :UNL PRODUCT s 4:PREMIUM PRODUCT L27:DISP 9-10 2ND NO VACUUM ALARM NO VACUUM ALARM OTHER SENSORS DEC 12, 2007 11 :00 AM MAR 28, 2008 3:04 AM FUEL ALARM AUG 17, 2007 5:47 PM COMMUNICATION ALARM NO VACUUM ALARM FUEL ALARM NOV 15, 2007 10:52 AM NOV 15, 2007. 11 :22 AM AUG 17, 2007 5:39 PM NO VACUUM ALARM NO VACUUM ALARM FUEL ALARM 110V 15, 2007 10:52 AM NOV 15, 2007 10:32 AM AUG 17. 2007 4:52 PM fi * r x END +F ie if 34 r r 4 * END n ri n END * ri ALARM HISORY REPORT ALARM HISTORY REPORT ALARM HISTOR`! REPORT --- SMARTSENSOR ALARM -_ --- SMARTSENSOR ALARM -- - 2:VAPOR LINE s 5:PREM1UNl VENT ----- SENSOR ALARM ----- C:OMMUNIC'ATION ALARM NO VACUUM ALARM L28:DISP 11-12 JAN 27. 2006 11 :33 PM OCT 19, 2007 11 : 15 AM DISPENSER PAN FUEL ALARM COMMUNICATION ALARM HIGH LIQUID ALARM AUG 17. 2007 3:31 PI 11 JAN 27. 2008 11 :31 RM OCT 19, 2007 10:55 AM FUEL ALARM COMMUNICATION ALARM 110 VACUUM ALARM AUG 17. 2007 3:30 PM JAN 27. 2008 9:46 PM OCT 19, 2007 10:54 AM FUEL ALARM MAR 6, 200E 1 :34 PM ti x * ri END ri n * 1: x END w � n r X END x ALARM HISTORY REPORT ALARM HISTORY REPORT --- SMARTSENSOR ALARM -- --- SMARTSENSOR ALARM -- ALARM HISTOR`i REPORT s 3:UNL VENT s 6:DIESEL PRODUCT NO VACUUM ALARM COMMUNICATION ALARM ----- SENSOR ALARM ----- FEB 13, 2008' 9:30 AM JAN 27, 2008 11 :52 PM L29:DISP 11-12 2ND OTHER SENSORS COMMUNICATION ALARM COMMUNI 'T�I. ON ALARM FUEL ALARM .JAN 2-7, 2006 11 :37 PM JAN 27. 11 :49 PM AUG 17. 2007 2: 18 PM COMMUNICATION ALARM r_OMMUNI" ON ALARM FUEL ALARM ' JAN 27, 2008 11 :35 PM JAN 27.'08 11 :37 PI°l MAR 6, 2006 1 :40 PM FUEL ALARM MAR 6, 2006 1 :40 PM - - ----- SENSOR ALARM ----- ALARM HISTORY REPORT ----- SENSOR ALARM ----- L 7:PREM STP SUMP 2ND L 2:UNL STP SUMP 2ND OTHER SENSORS --- Sh1ARTSENS0k ALARM - OTHER SENSORS FUEL ALARM s -:DIESEL VENT FUEL ALARM SEP 3, 2008 9:23 AM COMMUNICATION ALARM SEP 3. 008 9: IE All JAN 27, 2008 11 :55 PM COMMUNICATION ALARM JAN 27. 2008 11 :52 PM COMMUNICATION ALARM JAN 27, 2008 11 :37 PM ----- SENSOR ALNRt'9 ----- DID-' COUNTRY TEXACO 6009 COFFEE RD. L ?:PREM STP SUMP '2ND BAk:EkSFIELU.CA 93308 OTHER SENSORS FUEL ALARM SEP 3. 2008 9: 17 AM SEP 3, 2000 9:23 AM SYSTEM STATUS REPORT - - - - - - - - - - - L 7:FUEL ALARM s 4:NO VACUUM ALARM --- SENSOR ALARM ----- L l :DIESEL FILL SUMP 21111) OTHER SENSORS FUEL ALARM SEP 3. 2008 9: 17 AM ALARM HISTORY REPORT --- SMARTSENSOR ALARM -- B:AThI ----- SENSOR ALARM ----- L12:DIESEL FILL SUMP 2ND OTHER SENSORS FUEL ALARM ----- SENSOR ALARI-1 ----- SEP 3, 2008 9:26 All L a:UNL FILL PUMP OTHER SENSORS FUEL ALARM SEP 3, 2008 9:18 AM END ----- SENSOR ALARM ----- Ll5:DIESEL ANNULAR ANNULAR SPACE LOW LIQUID ALARM -- SENSOR ALARM ----- SEP 3, 2008 9:27 All L13:DIESEL FILL SUMP OTHER SENSORS SENSOR ALARM ----- FUEL ALARM LII :DIESEL STP SUMP SEP 3, 2008 9: 19 AM STP S S .BUMF FUEL ALARM SEP 3. 2008 9: 13 AM ----- SENSOR ALARhi ----- L15:DIESEL ANNULAR ANNULAR SPACE ALARM ----- HIGH LIQUID ALARM SENSOR ALARM SEP 3. _008 9:27 AM L 14:D I ESEL FILL SUMP 21,11) OTHER SENSORS SENSOR ALARM ----- FUEL ALARM L 6:PREM STP SUMP SEP 3, 2008 9:20 All STP SUMP FUEL ALARM SEP 3, 2006 9: 14 All ----- SENSOR ALARM ----- ----- SENSOR ALARM ----- L20:D1SP 3-4 ----- fiENSOR ALARM ----- L28:DISP 11-12 DISPENSER PAN LIO:PREII ANNULAR DISPENSER PAN FUEL ALARM SPACE FUEL ALARM SEP 3, 2008 9:36 All HIGH LIQUID ALARM SEP' 3, 2008 9:30 All SEP 3. 2006 9:28 AM ----- SENSOR ALARM ----- B1G COUNTRY TEXACO LIB:DISP 1-2 --- - SENSOR ALARM ----- 6009 COFFEE RD. DISPENSER PAN L 5:UNL ANNULAR BAYERSFIELD,CA 93308 FUEL ALARM SPACE SEP 3, 2008; 9:37 AM LOW LIQUID ALARM SEP 3, 2008 9:28 AM SEP 3, 2008 9:30 AM ----- SENSOR ALARM ----- SYSTEM STATUS REPORT L 5:UNL ANNULAR - - - - - - - - - _ - ANNULAR SPACE L28:FUEL ALARM HIGH LIQUID ALARM SEP 3. 2008 9:28 AM s 4:NO VACUUM ALARIt ----- SENSOR ALARM ----- L29:DISP 11-12 2ND OTHER SENSORS FUEL ALARM SEP 3, 2008 9:39 All ----- SENSOR ALARM ----- L S:UNL ANNULAR ANNULAR SPACE ----- SENSOR ALARM ----- LObJ LIQUID ALARM L26:D I SP 9-1 0 SEP 3, 2008 9:28 AM DISPENSER PAN ----- ;SENSOR ALARM ----- FUEL ALARM L27:DISF' 9-10 2ND SEP .3, 2008 9:31 AM OTHER SENSORS FUEL ALARM SEP 3. 2008 9:40 AM ----- SENSOR ALARM ----- L24:DISP 7-8 DISPENSER PAN ----- SENSOR ALARM ----- FUEL ALARM L25:Li I SP 7-8 211D SEP 3, 2008 9:32 All OTHER SENSORS FUEL ALARM SEP 3, 2008 9:40 All ----- SENSOR ALARM ----- L'22:DISP 5-6 DISPENSER PAN ----- SENSOR ALARM ----- FUEL ALARM L23:DISP 5-6 2ND SEP 3, 2008 9:35 AM OTHER SENSORS FUEL ALARM SEP 3, 2008 9:40 All --- SMARTSENSOR ALARM -- --- SHARTSENSOR ALARM -- - SENSOR ALARM ----- s 5:PREMIUM VENT s 3:UNL VENT L21 :DISP 3-4 211D IJU VACUUM ALARM NO VACUUM ALARM OTHER SENSORS SEP 3, 008 10'07 All SEP 3, 2008 10:42 All FUEL ALARM ` SEP 3, 2008 9:44 AM --- SMARTSENSOR ALARM -- --- SMARTSE1,2OR ALARM -- s 5:PREMIUM VENT s 2:VAPOR LINE ----- SENSOR ALARM ----- 110 VACUUM ALARM NO VACUUM ALARM L19:DISP 1-2 2ND SEP 3. 2008 10:10 AM SEP 3, 2008 10:43 All OTHER SENSORS FUEL ALARM SEP 3, 2008 9:44 All f BIG CUUIJTk'i TEXACO --- SMARTSENSOR ALARM -- 60U1J COFFEE RD. s -,:VAPOR LINE BAKERS:FIELD.CA 93308 •:»IGH LIQUID ALARM --- . ARTSEI,6'?,,)P ALARM -- SEP 3. 2008 10:46 All s 7:DIESEL VENT NO VACUUM ALARM SEP 3, 2008 10:10 AM SEP 3, 2008 9:52 AM i SYSTEM STATUS REPORT - - - - - - - - - - - - :. s 4:110 VACUUM ALARM --- SMARTSENSOR ALARM -- s i :UNL PRODUCT NO VACUUM ALARM --- SMARTSENSOR ALARM -- SEE' 3, 2008 10:47 All s 6:DIESEL PRODUCT NO VACUUM ALARM SEP 3, 2006 9:54 AM --- SHARTSENSOR ALARM -- s 4:PREMIUM PRODUCT HIGH LIQUID ALARM SEP 3. 2008 10:13 AM BIG COUNTRY TEXACO '6009 COFFEE RD. '! BAKERSFIELD.CA 93308 --- SMARTSENSOR ALARM -- s 6:DIESEL PRODUCT NO VACUUM ALARI°I SEP 3. 2008 10:48 AM SEP 3, 2008 9:56 All SYSTEM STATUS REPORT --- SMARTSENSOR ALARM -- s 3:NU VACUUM ALARM - - s 4:PREMIUM PRODUCT °1 VACUUM WARNING 4:NO VACUUM ALARM EP 3. 2008 -10:14 AM --- SMARTSENSOR ALARM -- s 4:PREM I Ut°1 PRODUCT -2:VAPUR LINE NO VACUUM ALARM SMARTSENSOR ALARM -- � SEP 3, 2008 10:14 All `_•jjp VACUUM ALARM :SEP 3. 2008 10:50 AM - STP-SUMP --- SENSOR ALARM ----- SENSOR OUT ALARM 6:D I SP .9-10 SEP 3. 2008 11 :53 AM -- SENSOR ALARM ----- SPENSER PAN L47:'VENT BOX 2ND EL ALARM }THER SENS0RS P 3, 2008 11 :32 AM ,UEL ALARM EP 3, 2008 11 : 12 All BIG COUNTRY TEXACO 6009 COFFEE RD. BAKERSFIELD-CA 93308 --- SENSOR ALARM ILIO:DISP 1-2 ---- SENSOR ALARM ----- DISPENSER PAM SEP 3. 2008 11 :54 AM 16:VENT BOX FUEL ALARM HER SENSORS SEP 3, 2008 11 :42 All UEL ALARM TM STATUS REPORT P 3.. 2008 1 l :13 All " SE_ T s 4:N0 VACUUM ALARM BIG COUNTRY TEXACO 6009 COFFEE RD. -- IN-TANK ALARM ----- BAKERSFIELD.CA 93308 I :UNL,EADED IGH PRODUCT ALARM P 3. 2008 11 : 16 AM SEP 3, 2008 11 :51 AP1 ----- SENSOR ALARM ----- L 1 :UNL STP SUMP STP SUMP SYSTEM STATUS REPORT FUEL ALARM - - - - - - - - - - - - SEP 3. 2008 11 :55 AM L 18:FUEL ALARI°i s 4:NO VACUUM ALARM -- IN-TANK ALARM ----- 2:PREI°1 I Ull IGH PRODUCT ALARM P 3• 2008 1 1 : 1 6 All ----- SENSOR ALARM ----- L I :UNL STP SUMP STP SUMP FUEL ALARM SEP 3, 2008--1-1 :57 AM ----- SENSOR ALARM ----- L 1 :UNL STP SUMP STP SUMP -- IN-TANK ALARM ----- SENSOR OUT ALARM 3:DIESEL SEP 3, 2008 11 :53 AM IGH PRODUCT ALARM P 3. 2008 11 : 17 All BIG COUNTRY TEXACO 6009 COFFEE RD. BAKERSFIELD,CA 93308 ----- SENSOR ALARM ----- SEP 3. 2008 11 :59 AM L I :UNL STP SUMP --- SENSOR ALARM ----- STP SUMP B:DISP 1-2 FUEL ALARM SPENSER PAN SEP 3, 2008 11 :53 AM SYSTEM STATUS REPORT EL ALARM s 4:NO VACUUM ALARM- - - P 3. 2008 11 :20 All ----- SENSOR ALARM ----- L 4:UNL FILL SUMP 2ND OTHER SENSORS FUEL ALARM SEP 3, 2008 12:06 PM BIG COUNTRY TEXACO 6009 T=OFFEE RD. BAKERSFIELD.CA 93308 SEP 3, 2008 12:07 PM SY'S'TEM STATUS REPORT s 4:N0 VACUUM ALARM SWRCB,January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Big Country Texaco Date of Testing: 9/3/2008 Facility Address: 6009 Coffee Road, Bakersfield,CA Facility Contact: James Young Phone: 661-327-5008 Date Local Agency Was Notified of Testing: 8/20/2008 Name of Local Agency Inspector(rf present during testing): Ernie Medina 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Service, Inc. Technician Conducting Test: Matthew Jennings Credentials: X CSLB Contractor X ICC Service Tech. ❑SWRCB Tank Tester ❑Other(Spec) License Number(s): CSLB#804904 ICC#5302760-UT 3. SPILL BUCKET TESTING INFORMATION Test Method Used: X Hydrostatic ❑Vacuum ❑Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket(fay Tank 1 Regular 2 Super a 3 Diesel 4 Number, Stored Product, etc.) Bucket Installation Type: ❑ Direct Bury ❑Direct Bury ❑ Direct Bury ❑ Direct Bury X Contained in Sump X Contained in Sump X Contained in Sump ❑Contained in Sum Bucket Diameter: 1 12.00" 12.00" 12.00" Bucket Depth: 13.25" 13.25" 13.25" Wait time between applying 5 Min. 5 Min. 5 Min. vacuum/water and start of test: Test Start Time(Ti): 9:30 am 9:30 am 9:30 am Initial Reading(Rj): 1 8.75" 9.00" 9.00" Test End Time(TF): 10:30 am 10:30 am 10:30 am Final Reading(RF): 8.75" 9.00" 9.00" Test Duration(TF—Ti): 1 hour 1 hour 1 hour Change in Reading(RF-Ri): 0.0" 0.0" 0.0" Pass/Fail Threshold or 0.0625" 0.0625" 0.0625" Criteria: Test Result: X Pass ❑Fail X Pass ❑Fail X Pass ❑Fail ❑ Pass ❑Fail Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information con aimed in this report is true,accurate,and in full compliance with legal requirements. Technician's Signature: "C--7:77 Date: 9/3/2008 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent.