HomeMy WebLinkAbout1102 UNION AVENUE (2)Range Hood Systems Report EXCELLENT FIRE PROTECTION 531 SUPPLY ROW TAFT CA 93268 (661) 765 -4343 C16-747594 Address 1102 c I Inke,, City �1__R State �� ZI P� � Telephone 3:23_n7au Store No. Owner or Manager COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT Grill DATE OF SERVICE 20. Replaced fuse links TIME 2. Duct and plenum covered w /correct nozzles Yes A.M. I P.M. ANNUAL SEMI-ANMWL�j N12tHARGE K TALLATION RENOVATION LOCATION OF SYSTEM ORLINDERS 24. Proper clearance -flame to filters UL 300 ❑YES ❑ NO M A R MBER WET Yes 7. If system has been discharged, report same -N/.A DRY CHEMICAL C M KtIZE MASTER L DER SIZE SLAVE 27. Fuel shut -off in on position CYLINDER SIZE SLAVE FUSEL 0° F. FUSE LINKS 450° F. FUSE LINKS 500° F. OTHER FUEL SHUT -OFF ELECTRIC GAS SIZE SERIAL NUMBER Yes 12. Inspect cylinder and mount LAST HYDRO TEST DATE Yes LAST RECHARGE DATE MANUFACTURER'S MANUAL REFERENCE PAGE NUMBER: DRAWING NUMBER: DATE 1. All appliances properly covered w /correct nozzles mss- 20. Replaced fuse links Yes 2. Duct and plenum covered w /correct nozzles Yes 21. Check travel of cable nuts /S -hooks e� 3. Check positioning of all nozzles. Yes 22. Piping & conduit securely bracketed 4. System installed in accordance w /MFG UL listing Yes 23. Proper separation between fryers & flame Yes 5. Hood /duct penetrations sealed w /weld or UL device _ 24. Proper clearance -flame to filters Yes � 6. Check if seals intact, evidence of tampering 25. Exhaust fan in operating order Yes Yes 7. If system has been discharged, report same -N/.A 26. All filters in place Yes 8. Pressure gauge in proper range (If gauged) 27. Fuel shut -off in on position Yes Yes 9. Check cartridge weight (If applicable) 28. Manual & remote set/seals in place Yes Yes 10. Hydrostatic test date 29. Replace systems covers Yes Yes 11. 6 year maintenance date 30. System operational & seals in place Yes Yes 12. Inspect cylinder and mount 31. Slave system operational Yes Yes 13. Operate system from terminal link Ys 32. Clean cylinder & mount N/A 14. Test for proper operation from remote es 33. Fan warning sign on hood Yes 15. Check operation of micro switch Yes 34. Personnel instructed in manual operation of system Yes 16. Check operation of gas valve 35. Proper hand portable extinguishers Yes Yes 17. Clean nozzles es 36. Portable extinguishers properly serviced Yes 18. Proper nozzle covers in place 37. Service & Certification tag on system Yes 19. Check fuse links and clean N/ NOTE DISCREPANICES OR DEFICIENCIES BELOW Yes COMMENTS: On this date, this range hood fire suppression system was inspected and operationally tested in accordance with the fire suppression syste5 requirements of NFPA17 or 17A, 96 and the manufacturer's manual, with the results indicated above. X 10/8/10 5:15 Stftttl ECHNICIAN PERMIT NO. DATE: TIME: AM PM CUSTOMER'S AUTHORIIZE0 AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. AUT6'-0®(f rN HAV! N G JU RISDOCT50H