Loading...
HomeMy WebLinkAboutSPRINKLER SYSTEM CHK 3-2011., Design, Installation, Inspection, & Repair of Fire Sprinkler Systems Bakersfield DATE: March 2011 San Francisco Livermore We herewith enclose a copy of an automatic fire sprinkler system check report for the following facility: Kern Federal Credit Union 1717 Truxtun Avenue Bakersfield, CA 93301 to the party checked below: Owner: Kern Federal Credit Union 1717 Truxtun Avenue Bakersfield CA 93301 kw'l -3a7,1 -44U/ Fire Dept: Bakersfield City Fire Department Fire Prevention Division 1501 Truxtun Avenue Bakersfield, CA 93301 Thank You RLH Fire Protection File: 7180 cc: R L H Fire Protection 3430 Unicom Rd. Bakersfield, CA 93308 Voice:661.322.9344 Fax:661.322.6816 Lic.# 777717 . ANNEX B Inspection, Testing, and Maintenance Fire Sprin Date Of Inspection, Testing, Maintenance: 03/2412011 Property Information: Name: Kern Federal Credit Union Address: 1717 Truxtun Avenue City: Bakersfield System Riser ID: 7180 Type Of System: ❑ X Wet Pipe ❑ Dry Pipe ❑ Preaction ❑ Deluge Main Drain Test Results: Initial Static Pressure: (psi) Residual Pressure: (psi) Restored Static Pressure: (psi) Abbreviation Key: I = Inspection T = Test M = Maintenance A -O = After Operation MI = Per Manufacturer's Instructions Item Activity Frequency Description NFPA 25 Reference Fail N/A Pass 1.1 I Daily Week/ Preaction /Deluge Valves - Enclosure tem erature 12.4.3.1 X 1.2 I Daily WeekIv Dry Pipe Valves - Enclosure tem erature 12.4.4.1.1 X 1.3 I Quarterly Gauges - (Dry, Preaction, Deluge S stems 5.2.4.2 5.2.4.3 X 1.4 1 Quarterly Control Valves 12.3.2.1 X 1.5 1 Quarterly Alarm Devices 5.2.6 X 1.6 I Quarterly Gauges (Wet Pipe Systems) 5.2.4.1 X 1.7 I Quarterly Hydraulic nameplate 5.2.7 X 1.8 I Quarterly Pipe and Fittings 5.2.2 X 1.9 1 Quarterly Sprinklers 5.2.1 X 1.10 1 Quarterly Spare Sprinklers 5.2.1.3 X 1.11 1 Quarterly Fire Department Connections 12.7.1 X 1.12 1 Quarterly Alarm Valves - Exterior Inspection 12.4.1.1 X 1.13 1 Quarterly Quarters Preaction /Deluge Valves - Exterior Inspection 12.4.3.1.6 X 1.14 1 Quarterly Pressure Reducing Valves 12.5.1.1 X 1.15 1 Quarterly Dry Pipe Valves- Exterior. Inspection 12.4.4.1.4 X 1.16 1 Quarterly Backflow Preventers 12.6.1 X 1.17 j 17 Annual Buildings 5.2.5 X State Fire Marshal AES 2 Inspection performed by: RLH Fire Protection - Bakersfield, CA - 777717 March 21, 2006 Page 1 of 5 ANNEX B Item Inspection, Testing, and Maintenance Fire Sprinkler System NFPA 25 Chapter 5 as amended bv CCR Title 19 Frequency Date Of Inspection, Testing, Maintenance: 03/24/2011 System Riser ID: 7180 Fail Property Information: Pass Type Of System: A >.;:.. Name: Kern Federal Credit Union ❑X Wet Pipe Address: 1717 Truxtun Avenue ❑ Dry Pipe 1 Annually Seismic Braces ❑ Preaction X Deluge 1 City: Bakersfield Hangers (Accessible concealed spaces) 5.2.3.3 ": `:... W .• Item Activity Frequency Description NFPA 25 Reference Fail N/A Pass 1.18 1 Annually Hangers 5.2.3 X 1.19 1 Annually Seismic Braces 5.2.3 X 1.20 1 5 Years Hangers (Accessible concealed spaces) 5.2.3.3 X 1.21 1 5 Years Seismic Braces (Accessible concealed Spaces) 5.2.3.3 X 1.22 1 5 Years Pipe and Fittings (Accessible concealed spaces 5.2.2.3 X 1.23 1 5 Years Sprinklers (Accessible concealed spaces) 5.2.1.1.4 X 1.24 1 5 Years Alarm Valves - Interior Inspection 12.4.1.2 X 1.25 1 5 Years Alarm Valves - Strainers, filters, orifices 12.4.1.2 X 1.26 1 5 Years Check Valves - Interior Inspection 12.4.2.1 X 1.27 1 5 Years Preaction /Deluge Valves - Interior Inspection 12.4.3.1.7 X 1.28 1 5 Years Preaction/Deluge Valves - Strainers, filters, orifices 12.4.3.1.8 X 1.29 1 5 Years Dry Pipe Valves - Interior Inspection 12.4.4.1.5 X 1.30 1 5 Years Dry Pipe Valves - Strainers, filters, orifices 12.4.4.1.6 X 2.1 T Annually Alarm Devices (90 Sec) 5.3.3 12.2.7 X 2.2 T Annually Main Drain Test (Enter data on Page 1) 12.2.6 12.2.6.1 12.3.3.4 X 2.3 T Annually Antifreeze Test 5.3.4 X 2.4 T Annually Control Valve - Position 12.3.3.1 X 2.5 T Annually Control Valve - Operation 12.3.3.1 X 2.6 T Annually Supervisory 12.3.3.5 X 2.7 T Annually Preaction Valve - Priming Water 12.4.3.2.1 X 2.8 T Annually Preaction Valve - Low Air Pressure Alarm 12.4.3.2.10 X 2.9T Annually Preaction Valve - Full Flow Trip Test 12.4.3.2.2 X March 21, 2006 Page 2 of 5 ANNEX B Inspection, Testing, and Maintenance Fire Sprinkler System NFPA 25 Chapter 5 as amended b -CCR Title 19 Date Of Inspection, Testing, Maintenance: 03/24/2011 Property Information: Name: Kern Federal Credit Union Address: 1717 Truxtun Avenue City: Bakersfield System Riser ID: 7180 . >. Type Of System: :`= GQC4° O L c.,. ❑X Wet Pipe ❑ Dry Pipe ❑ Preaction v ❑ Deluge Item Activity Frequency Description NFPA 25 Reference Fail N/A Pass 2.10 T Annually Dry Pipe Valve - Priming Water 12.4.4.2.1 X 2.11 T Annually Dry Pipe Valve - Low Air Pressure Alarm 12.4.4.2.6 X 2.12 T Annual/ Annually Dry Pipe Valve - Quick- Opening Device 12.4.4.2.4 X 2.13 T Annually Dry Pipe Valve - Trip Test 12.4.4.2.2 X 2.14 T Annually Backflow Preventor Assemblies 12.6.2 X 2.15 T 3 Years Dry Pipe Valve - Full Flow Trip Test 12.4.4.2.2.2 X . 2.16 T 5 Years Gauges 5.3.2 X 2.17 T 5 Years Pressure Reducing Valve 12.5.1.2 X 2.18 T 5 Years Fire Department Connection Backflush 12.7.4 X 2.19 T 5 Years Sprinklers - Extra High Temperature 5.3.1.1.1.3 X 2.20 T 5 Years Sprinklers - Corrosive environment or corrosive water 5.3.1.1.2 X 2.21 T 10 Years Sprinklers- Dry 5.3.1.1.1.5 X 2.22 T 20 Years Sprinklers - Fast Response 5.3.1.1.1.2 X 2.23 T 50 Years Sprinklers 5.3.1.1.1 X 2.24 T 75 Years Sprinklers 75 years in service 5.3.1.1.1.4 X 2.25 T Sprinklers manufactured prior to 1920 - Re lace 5.3.1.1.1.1 X 3.1 M Annually Control Valves 12.3.4 X 3.2 M Annually Preaction /Deluge Valves 12.4.3.3.2 X 3.3 M Annually Dry Pipe Valves /Quick- Opening Devices, 12.4.4.3.2 X 3.4 M Annually Dry Pipe Valve - Low Point Drains 12.4.4.3.3 X 3.5 M 5 Years I Obstruction Investigation Chapter 13 X State Fire Marshal AES 2 March 21, 2006 Inspection performed by: RLH Fire Protection - Bakersfield, CA - 777717 Page 3 of 6 ANNEX B Inspection, Testing,.and Maintenance Fire Sprinkler System NFPA 25 Chapter 5 as amended bv CCR Title 19 Date Of Inspection, Testing, Maintenance: 03/24/2011 Property Information: Name: Kern Federal Credit Union: Address: 1717 Truxtun Avenue City. BakersfieldAE System Riser ID: 7180 Type Of System: O� CACi�`. ~' ❑X Wet Pipe �r..... ter; qp ❑ Dry Pipe ❑ Preactiona: Deluge i. Item Deficiencies and Comments: Deficiencies and Comments Item number must correspond to the Item number of the activity listed above: ❑ See Continuation Page(s) (Indicate the number of continuation pages) x PASS ❑ F1 FAIL a . +,::...,.; 03/24/2011 Signature Date State Fire Marshal AES 2 March 21, 2006 Inspection performed by: RLH Fire Protection - Bakersfield, CA - 777717 Page 4 of 5 inspection performed by: RLH Fire Protection - Bakersfield, CA - 777717 Page 5 of 5