Loading...
HomeMy WebLinkAboutFIRE PREV. INSP 9/17/2010r _ t 1 BAKERSFIELD FIRE FIRE PREVENTION INSPECTION DEPARTMENT ` W2 E R S F f E L D -' `-- T FIRE Prevention Services _ I DE ARTMENT 2101 H Street - - -- - - - -- -1 Bakersfield. CA 93301 DISTRICT BLOCK NO. DATE %::/)— FEE FACILITY ADDRESS CITY, STATE,. ZIP FACILITY NAME ... LO J n `�- MANAGERS NAME PH NO.� / J� BUSINESS OWNER'S NAME AND ADDRESS s i CITY, STATE, ZIP ,. PH NO. —2 p / I BILL TO: CIF DIFFERENT FROM ABOVE) NAME, ADD E55- p it Cn .4.A% K CITY, STATE, ZIP, PH NO. OCC TYPE J `:. OCC LO D - NO. OF FLOORS HIGH RISE BLD RISER DATE " // o' 7'flti 19 YES No IF CORRECT ALL VIOLATIONS VIOLATION / REQUIREMENTS ' CHECKED BELOW i, 1 an )d"sa ly dispose of all hazardous refuse and dry vegetation on the above premises (CFC COMBUSTIBLE WASTE / DRY VEGETATION .Remove 304.1.1) 2 Provide non- combustible'(coritainers with tight fitting lids for the storage of combustible waste and rubbish pending its safe disposal. (CFC 304.3.1) coeu�sr�iBLg„S,T.ORAGE�`„- j Relocate combustible storage to provide at I�asG +3 feet clearance around motor fuse box /fire door (CFC 605.3) q' GRelocate fire extinguisher(s) so that they will be in a conspicuous location, hanging on brackets with the r' top to -the extinguisher not more than 5 feet.above the floor. (CFC 906.5 & 906.9) EXTINGUISHERS 5 Provide and install amount ( ) _____ approved (type &size) __________________ portable fire extinguisher to be immediately accessible for use in (area) _____________________________ (CFC TABLE 906.3(1)) 6 Re- charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and /or after each use, by a person having a valid license or certificate. (CCR TITLE 19: 575.1) 7 Provide and maintain "EXIT" sign(s) with letters 5 or more inches in height over each required exit SIGNS (door /window) to fire scape. (CFC 1011.5.1) 8 Provide and aintain a propriate numbers on a contrasting background and visible from the street to indicate t c rec dd ss of the building. (CFC 505.1) 9 Repair all cr s, /holes /openings) in plaster in (location) --------------------------------------- FIREDOORS/ FIR E SEPARATIONS Plastering h I eturn the surface to its original fire resistive condition. (CFC 703.1) 10 ___ _______________________________ _____ ___ _ Remove /re it (item & location) ------------------------------------------------------ Se - closing oors shall be designed to•.close by gravity, or by the action of a mechanical'devicd� or by an, app d smoke and heat sensitive device. Self - closing doors shall have no attachments capable of p ev i g the operation of the closing device. (CFC 703.2) EXITS 11 Re all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1028.3) 12 r ide a contrasting colored and permanently installed electric light over or near required exit cation) ______________________________ to clearly indicate it as an exit. (CFC 1006.3) STORAGE Remove all storage and /or other obstructions from fire escape landings and stairways stair shafts. (Fire escapes /stair shafts are to be maintained free from obstructions at all times.) (CFC 1028.3) J14 Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved ELECTRICAL APPLIANCES electrical outlets where needed. (CFC 605.5) 15 Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC 605.4) OUTDOOR BURNING 16 Recreational fires or open burning. CFC 307.1 FIREWORKS 17 Violations of Section (CFC 3308.1) & 8.44.040 (B.M.C.). OTHER �.a•` 18 0 a,11 e Al h6 AC CUSTOMER: /~ LEGEND` (Si natu ` (Please Print Name Legibly, Title) C.F.C. CALIFORNIA FIRE CODE C.B.C. CALIFORNIA BUILDING CODE B.M.C. BAKERSFIELD MUNICIPAL CODE �J INSPECTOR: NO.: N.F.P.A. NATIONAL FIRE PROTECTION Sys e) ASS CIATION N.E.C. NATIOONAL E ECTRIC CODE White - Customer /Original Yellow - Station Copy Pink - Prevention Services FD 2022 (Rev. 08/10)