HomeMy WebLinkAbout2200 FAITH AVENUE_FI 9.14.10FIRE PREVENTION INSPECTION
li
B W IN / E R S F \)E \L D
FIRE
u ARIM , T
BAKERSFIELD FIRE
DEPARTMENT
Prevention Services
2101 H Street
Bakersfield, CA 93301 /
DISTRICT
BLOCK NO.
DATE _ .`
(�
FEE �...• /D'
FACILITY ADDRESS
CITY, STATE, ZIP
FACILITY NAME (�� +, --^.
MANAGER'S NAME
PH NO. n7
BUSINESS OWNER'S NAME AND ADDRESS r% 'V a'ci /
L
_
CITY, STATE, ZIP f �V/0,
PH NO.0 -
BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS
f
CITY, STATE, ZIP,(/ / ;
1
PH NO.
lfli(_/
_ O
�-OCC TYPE
L
OCC LOAD
pvv/ ,.O�O. OF FL RS
Ar py Z —
HIGH RISE BLDG
� YES NO
RISER DATE
Q
CORRECT ALL VIOLATIONS VIOLATION
REQUIREMENTS
CHECKED BELOW NO.
^1
Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC
COMBUSTIBLE WASTE / DRY
VEGETATION
304.1.1 )
2
Provide non - combustible containers with tight fitting lids for the storage of combustible waste and
rubbish pending its safe disposal. (CFC 304.3.1)
COMBUSTIBLE STORAGE
• 3
Relocate combustible storage to provide at least 3 feet clearance around motor fuse box /fire door (CFC
605.3)
4
Relocate fire extinguisher(s) so that they will be in a conspicuous location, hanging on brackets with the
top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9)
EXTINGUISHERS
". 5
Provide and install (amount) _____ approved (type & size) __________________ portable fire
extinguisher to be immediately accessible for use in (area) _____________________________ (CFC
TABLE 906.3(1))
6
Re- charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and /or
after each use, by a person having a valid license or certificate. (CCR TITLE 19: 575.1)
7
Provide and maintain "EXIT" sign(s) with letters 5 or more inches in height over each required exit
SIGNS
(door /window) to fire escape. (CFC 1011.5.1)
8
Provide and maintain appropriate numbers on a contrasting background and visible from the street to
indicate the correct address of the building. (CFC 505.1)
9
Repair all (cracks /holes /openings) in plaster in (location) ________ ______________________.
FIRE DOORS/
FIRE SEPARATIONS
Plastering shall return the surface to its original fire resistive condition. (CFC 703.1)
10
Remove /repair (item & location) ----------------------------------------------------------
Self- closing doors shall be designed to close by gravity, or by the action of a mechanical device, or by an
approved smoke and heat sensitive device. Self- closing doors shall have no attachments capable of
preventing the operation of the closing device. (CFC 703.2)
EXITS
11
Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1028.3)
12
Provide a contrasting colored and permanently installed electric light over or near required exit
(location) ______________________________ to clearly indicate it as an exit. (CFC 1006.3)
STORAGE
13
Remove all storage and /or other obstructions from fire escape landings and stairways stair shafts. (Fire
escapes /stair shafts are to be maintained free from obstructions at all times.) (CFC 1028.3)
14
Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved
ELECTRICAL APPLIANCES
electrical outlets where needed. (CFC 605.5)
15
Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC
605.4)
OUTDOOR BURNING
16
Recreational fires or open burning. CFC 307.1
FIREWORKS
17
Violations of Section (CFC 3308.1) & 8.44.040 (B.M.C.).
OTHER
18
J
I
CUSTOMER: 1.
LEGEND:
C.F.C. CALIFORNIA FIRE CODE
(Suture) lease Print Name Legibly, Title)
9
C.B.C. CALIFORNIA BUILDING CODE
B.M.C. BAKERSFIELD MUNICIPAL CODE
INSPECTOR: ' e0i' u��'Y NO.: 77z—
N.F.P.A. NATIONAL FIRE PROTECTION
(Signature)
ASSOCIATION
N.E.C. NATIONAL ELECTRIC CODE
FD 2022 (Rev. 08 /10)
White - Customer /Original Yellow - Station Copy Pink - Prevention Services