HomeMy WebLinkAbout3000 SILLECT AVENUE_BAKERSFIELD PATHOLOGY HMBP 3.8.11UNIFIED PROGRAM INSPECTION CHECKLIST
SECTION 1: Business Plan and Inventory Program
ram
B F. R S F I IE L D
4 O F /IPE --
FIRE
'A r
BAKERSFIELD FIRE DEPT.
Prevention Services
2101 H Street
Bakersfield, CA 93301
Tel.: (661) 326 -3979
Fax: (661) 852 -2171
FACILITY NAME
INSPECTION DATE
INSPECTION TIME
ADDRESS ,
PHONE NO.
NO OF EMPLOYEES
FACILITY CONTACT
BUSINESS ID NUMBER
Consent to Inspect Name /Title
Section 1: Business Plan and Inventory Program
❑ ROUTINE •O° COMBINED ❑ JOINT AGENCY ❑ MULTI - AGENCY ❑ COMPLAINT ❑ RE- INSPECTION
C v
C= Compliance OPERATION
V= Violation
COMMENTS
T
❑ ,eta
APPROPRIATE PERMIT ON HAND
(BMC: 15.65.080)
❑ 2(
Business PLAN CONTACT INFORMATION ACCURATE
(CCR: 2729.1)
�����'� � � / � r- S
f
E,Q ❑
VISIBLE ADDRESS (CFC: 505.1, BMC: 15.52.020)
If19 ❑
CORRECT OCCUPANCY
(CBC:401)
(]p ❑
VERIFICATION OF INVENTORY MATERIALS
(CCR: 2729.3)
❑ ❑
VERIFICATION OF QUANTITIES
(CCR: 2729.4)
r
DI ❑
VERIFICATION OF LOCATION
(CCR: 2729.2)
❑� ❑ PROPER SEGREGATION OF MATERIAL (CFC: 2704.1)
IND' ❑
VERIFICATION OF MSDS AVAILABILITY
(CCR: 2729.2(3)(b))
❑ ❑
VERIFICATION OF HAZ MAT TRAINING
(CCR: 2732)
I
CEO ❑
VERIFICATION OF ABATEMENT SUPPLIES & PROCEDURES (CCR: 2731(c))
I ❑
EMERGENCY PROCEDURES ADEQUATE
(CCR: 2731)
(]0 ❑
CONTAINERS PROPERLY LABELED (CCR: 66262.34(f), CFC: 2703.5)
❑V ❑
HOUSEKEEPING
(CFC: 304.1)
CJ� ❑
FIRE PROTECTION
(CFC: 903 & 906)
11- ❑
SITE DIAGRAM ADEQUATE & ON HAND
(CCR: 2729.2)
ANY HAZARDOUS WASTE ON SITE? ®AYES ❑
NO
Signature.ofReeeipt
Explain:
\
POST INSPECTION INSTRUCTIONS:
• Correct the violation(s) noted above by
• Within 5 days of correcting all of the violations, sign and return a copy of this page to:
Bakersfield Fire Dept., Prevention Services, 2101 H Street, California 93301
While — Business Copy Yellow — Business Copy to be Sent in after return to Compliance
Signature (that all violations have been corrected as noted)
Date -
Pink — Prevention Services Copy
FD2155 (Rev 010)
W.
HAZARDOUS WASTE BAKERSFIELD FIRE DEPARTMENT
UNIFIED PROGRAM CONSOLIDATED FORMS !2 Prevention Services
FIRS 1501 Truxtun Ave 1sT FLR
HAZARDOUS WASTE GENERATOR *�ARTX T Bakersfield, CA 93301
INSPECTION REPORT Phone: 661 - 326 -3979 . Fax: 661- 852 -2171
Facility-Name S "'lA V_ Cz a-� i C. L-T' Yf i Date
Site Address-3 0 UU .5 i L(- E c_•i- 1� V C w I Time In Time Out
Owner /Operator Phone t ° U� C_ . Misc.
Type of Inspection Inspection Consolidation • EPA ID
❑ Routine ❑ Re- inspection/Follow -up ❑ Combined Routine Inspection ❑ Joint Inspection ❑ Complaint ❑ Focused ❑ Other
❑ Integrated or Multi -Media Inspection CUPA Facility ID#
❑ CONSENT TO INSPECT GRANTED BY (Name/ Title):
Inspection may involve obtaining photographs, review and copying of records, and determination of compliance with hazardous waste handling requirements
1 - Class I Violation, II - Class 11 Violation, M - Minor Violation
Pape of
1
11
M
HAZARDOUS WASTE REQUIREMENTS
Code I
Y
N
N/A
COMMENTS /NOTES✓DOCUMENT(S) REVIEWED
MISSING INFORMATION/ UNRESOLVED ISSUES
Recordkee in documentation
GR01
Generator has an EPA ID number
GR02
Hazardous waste determination made for all wastes
❑ Analysis -1B Generator Knowledge
s
GR03
Contingency Ian information posted near phone
GR04
Facility personnel demonstrate training/awareness
q
GR05
Manifests/Consolidated Manifest receipts complete I
n
GR06
Blue co (s) of manifest mailed to DTSC
c
GR07
TSDF signed copy of manifest available w /in 35
days of waste shipment
1 .11
Y
GRO8
Bills of Lading/receipts available
�.•
GR09
LDRs available and complete
"
GRIO
Onsite recycling reported using UPCIF
_
Container /tank management
GCOI
Containers are in good condition
,
GCO2
Containers are closed except when adding/removing
GC03
Empty containers are empty
�)
GC04
Containers inspected weekly
GC05
Tanks inspected daily
GC06
Satellite containers at or near point of generation
GC07
Satellite containers under control of operator
GCO8
One container per wastestream at satellite area
GC09
Exclude recyclable materials stored in accordance
with local ordinance/hazardous materials codes
Accumulation Time Limits
GA01
Waste is accumulated not more than 90/180/270 t
GA02
Satellite wastes accumulated for less than 1 year
GA03
Empty containers managed within one year
GA04
Universal waste accumulated less than one year 9
GA05
Used oil filters offsite within 180 (1 year if <1 ton)
"
GA06
Pb -acid batteries offsite within 180 1 yr. if < l ton)`
LabetingfMarking
GLO1
Containers are properly labeled F'
GL02
Satellite containers have 2" ASD marked once full
w
GL03
Excluded recyclable materials marked properly
GL04
Universal waste container properly labeled
-�
GL05
Used oil filters marked "drained used oil filters'
GL06
Date written on spent lead -acid batteries
GL07
"Used Oil" marked on all used oil tanks /containers
GL08
Tank marked with "haz waste" , contents, start date
GL09
Empty containers marked with date emptied
Treatment Transport and Disposal/Other
Print and sign in this box for receipt of this report. Signature does
not imply agreement with findings, only receipt of report.
i ( ` i •' 1. f
i
GT01
Have pe rnidauthorization to do treatment
GT02
Waste sent with authorized transport (en. eligible)
GDOI
Waste disposed of to authorized pointt art
(
GH01
Failed to properly handle applianc e wastes
POST INSPECTION INSTRUCTIONS:
• Refer to the back of this inspection report for regulatory citations and corrective actions
• Correct the violation(s) noted above by
• Within 5 days of correcting all of the violations, sign and return a copy of this page to:
Bakersfield Fire Dept., Prevention Services, 1501 Truxtun Avenue, California 93301
Signature (that all violations have been corrected as noted)
Date
White — Prevention Services Copy Yellow— Business Copy
FD2179 (Rev 10!21108)
Reaulatory Citations and Corrective Actions
1 9 D21--ha tie 1011 nr
Description of violation Regulatory /statutory citationj Corrective actions to he taken for minor violations marker! in the "Al" column an 'rota)
GR01
The facility failed to obtain an EPA ID number [Title 22, CC: R, 66262.12] Fora California EPA ID # contact the Department gfToxic Substances Control at
1 -800- 611 -6942. For a EPA iD # ca114 /5- 495 -1195. IVrite the number in the space marked "EPA ID # "on the /front of this page.
GR02
The facility failed to make a waste determination for the noted in the
[Title 22, CCR, 66262.11 ]Blake a determination of the waste based on your knovledge (you can use hISDS or other clocuments.for help) or have the waste
saint lecl sand sent to a state certiliecl laboraatory for amah sis. !f sash ding is conducted tell the lab to ahalhze for
GIt03
The facility did not have the name and phone number of the emergency coordinator, the location of fire extinguishers and spill control equipment, or the fire
department telephone number posted next t o t he telephone. I Title 22, CC: R, 66262.34(d)(2) Prepare and post the above inform alion nest to ar phone.
GIZ04
Facility personnel did not demonstrate that they were familiar with proper waste handling procedures due to
Title 22, CCR, 66262.34(4)(2) Provide training to personnel regarding
GR05
The facility failed to properly complete a hazardous waste manifest. Manifest # was missing
[Title 22, CCR, 66262.23(a)(1)]. Correct the inlornnlioa oil the manifest in Bowes) initial and (late. Submit a letter to DISC. GISS :; P.O.
Box ,Y06 Flrl -l: Sacramento, CA 95112 -0806 stating the manifest #, the ship date, Your EPA iD #. the Box # and correction made and your signature.
(Correction for more that one manifest muav be included in the saute letter)
GR06
Facility failed to submit a copy of the manifest to DTSC within 30 days of shipment. [Title 22, CCR, 66262.32(x)(4)] Alail the blue copy glmanilest
# to: DTSC. PO Box 400. Sacramento, CA 95112 -0400 or a photoco v of the TSDF co py to: DTSC. PO Box 3000, Sacramento, CA 95812
GR07
The facility failed to file an exception report to DTSC: after not receiving the signed TSDF copy of a manifest within 35 days. ["Title 22, CCR, 66262.421
Make a colt' of tare manifest and send it with a letter to DTSC. PO Box AAA, Sacramento, CA 95812 status; what you on are rlonrg toJind opal av /(v you tun +e not
received the lineal, signed co v ol'the m atsilest. Include a signature and your lindin,gs while looking for the manifest in the cover letter.
GROS
The facility failed to have copies ofreceipts for the removal of . [HSC 25160?- Consolidated manifests / 66266.31(a)(6)(B)-
lead acid batteries /66266.130- oil filtersi The facility shall contact and request copies of receipts between cl•
GR09
The facility failed to complete or maintain a Land Disposal Restriction notification for manifest # ['title 22, CCR, 66262.34(a)(4)]
The /ocility shall determine ifits waste is subiect to LDR requirements, and i /so, ensure that a LDR is re tared and submitted with each shipment olwaste.
GR10
'file facility did not submit a recycling report [HSC 25143.10) The.lacilit shall complete and submit the UPCFfortn "Recyclable Materials Report ". The
form can befound at www.cale a.ca. rov/ ublications /title27 /default.l tin (Hmfreeyc. pill)
GC01
The facility failed to maintain containers holding hazardous waste in good cond it 10 11, The container of was
Title 22, CCR, 66262.34(a)(1)(A) Tlae contents ol'tlre cotntabu:r of shall immediately be 0•ansferred to a container in good condition
GC:02
'file facility failed to keep containers closed except when adding /removing waste. The container of was observed open ['title 22, CCR,
66262.34(a)(I )(A) . The /facility shall inrtnediately close all containers and ensure that containers remain closer/ evice t when adding or• re movink hwaste.
GC:03
The facility is handling contaminated containers as empty when they are not. A container of was noted as not meeting the definition of
empty. [Title 22, CCR, 66261.7] Tlhefiacilit .shall mark the container as• hazardous waste or consolidate the contents ql't he container
with a like waste and immediately label the emptied container- with the words "em t- "anal the date.
GC04
The facility could not demonstrate that containers were being inspected weekly. [Title 22, CCR, 66262.34(a)(1)(A)] Thefcacilit- shall develop and implement
a plan that ensures that all containers holding waste are inspected weekly
GC05
The facility could not demonstrate that tanks were being inspected daily. [Title 22, CCR, 66262.34(a)(1)(A)] TlreJircility shall keep a log showing that tanks
holding waste are inspected daill.
GC06
Containers utilizing satellite accumulation rules were not at or near the point of generation. [Title 22, CCR, 66262.34(e)(I)(A)l The fhcilit+sh all move the
container holcling to a location that is at or near the point ol'genernion or shall ensure that the waste is removed within 9011801270
days of first drop of waste being added (if the lucility ,generates less than 100 kg, the clock does not start until 1110 kg. are generated)
GC07
Containers utilizing satellite accumulation rules were not under the control of aft operator. [Title 22, CCR, 66262.34(e)(1)(A)i The facilit- shall ensure that
nth operator is at or near the point of'accuntulcuion or shall ensure that the waste is removed within 90 11x0 /270 days of first drop o /'waste being adeleal
GC03
The facility kept more than one satellite container of at a satellite accumulation area. [Title 22, CCR, 66262.34(e)(1 )] Thefacilily
shall immediately remove all but one container !rout the accumulation area or shall demonstrate that it is not practical or sale to do such.
0009
The facility stored excluded recyclable materials not in accordance with local ordinance /fire code /hazardous materials codes [HSC 25143.9(c)l Theficility
shill return to code by
GA01
The facility accumulated waste for greater than allowed time limits (Storage without a permit). A container of had an start date of
marked on it. [Title 22, CCR, 66262.34(a)] The l acility shall inanediately arrange for the removal of the waste, and shall supply a copy gf'lhe nuty6t or bill
or ladirhg demonstrating removal within days.
GA02
The facility held satellite accumulation wastes for greater than one vear. ITille 22, CCR, 66262.34(e)(I )(B)l .See GA01 above (or corrections.
GA03
The facility failed to properly handle contaminated containers within I year. 'Title 22, CCR, 66261.7(f) See GA01 abort: lot- corrections.
GA04
The facility held universal wastes for greater than one year. Title 22, CCR, 66273.15(x) or 66273..35(x) See GA01 above for corrections.
GA05
The facility held drained used oil filters for greater than 180 days /one year. "Title 22, CCR, 66266.I30(c)(4) See GA01 abo e la• corrections.
GA06
The facility held lead acid batteries for greater than 130 days /one year. 'rifle 22, CCR, 66268.8 1 (a)(6)1 See GA01 above for corrections.
GLOI
The thcility failed to properly label all containers. Containers, contents and missing information are noted on the front of this page. [fide 22, CCR,
66262.34(t)] The fiacility shall clearly mark all containers with the following 1) the wards "Hazardous waste ", 2) composition (and physical state. 3) hazard
property. 4) name and address oltne,generattor•, cod 5) accumulation start dare.
CH-02
'file facility failed to mark the date the container was moved front the satellite accumulation area [Title 22, CCR, 66262.34(e)(I )(B)l The facility shall mark
all satellite accumulation with the date waste is first added as well as the dale the container is lull.
GL03
The facility failed to mark tanks /container(s) of excluded recyclable materials properly [HSC 25143.9(a)] The tanks /containers of'materials shall be clear /•
marked with the words "Excluded recyclable material" instead of "'hazardous waste ".
GL04
The facility failed to mark a container of universal waste properly. [Title 22, CCR, 66273.14 for SQH or 66273.34 for LQH ]. The facility shall inunctiately
mark all containers holding universal waste with the words "Universal Waste- "
GI-05
The facility failed to mark a container of drained used oil filters with the words "drained used oil filters'. [Title 22, CCR, 66266.130(c)(3)1 The fiac•ilit shall
mark all filter containers with the words "drained used oil filters ".
GL06
The facility failed to mark the date on which the battery was received. Title 22, CCR, 66266.8 1 (a)(6)(D)l The lacillty shall v mark the date on each buttery.
GL07
The facility failed to mark a tank /container of used oil destined tor recycling with the swords "used oil" [HSC 25143.9(a)1 Clearly mark all tanks and
containers with the words "used oil ".
GI-03
The facility failed to mark the tank of with the ['fitle'22, CCR, 66234(1)] TheJacilitV shall
c'learlw mark the talk with
GI -09
The facility failed to mark contanninated containers with the date em ptied. jTi tle 22, CC: R, 66261.7(t) Clearly murk all containers with the (late emptied.
GI-101
The facility failed to remove from an appliance prior to crushing, baling, shredding, sawing or disposing of the appliance [HSC .
25212(a)]. The lcacility m a ust submit to DTSC an lication to be certified as a "Certilied.4pl3liance Recycler"
GTOI
The lac i I i ty failed to obtain a permit or other authorization for treatment of hazardous waste. 1-I SC 25189.5(d)
GT02
The facility failed to use a registered transporter/used a transporter or consolidated waste when thev were not eligible f 1-I SC 25165(a)/25160
GDOI
The facility disposed of hazardous waste at an unauthorized point. [HSC 25139.5(a)
1 9 D21--ha tie 1011 nr