Loading...
HomeMy WebLinkAbout3300 SILLECT Avenue_AST611111 07 HOODS ALARMS SPRNKLER SYSTEMS SPRAY BOOTH AST UST Permit No. Permit No. Permit No. Permit No. Permit No. Permit No. /foam X60 File Number: 5T 3 3 Address: 33CO S� lfe_77 Bakersfield, CA 933 Date Received: t5- a-G' - Business Name: ,",1,J l�ea re SYSTEM: BUILDING SQUARE FEET: New Mod. ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ az ❑ ❑ ❑ minor modification removal Commercial Hood System Fire Alarm System Fire Sprinkler System Spray Finish System Aboveground Storage Tank Underground Storage Tank Underground Storage Tank Underground Storage Tank ❑ ❑ Other: Building Sq. Feet: Calculation Bldg. Sq. Ft: 1. Comments: C-- ��.��r- _ �cJ Q--< I Aal 6c INSPECTION LOG vate ,-I Signature Signature uu�iu� BILLING & PERMIT STATEMENT �o'�ID' BAKERSFtELD FIRE DEPARTMENT 3 a Prevention Services PERMIT ,# T 2101 H Strdet �ABTM ,-„ 6 Bakersfield; CA 93301 I- Dhnr.o. rzrzi _13 )L_Z070 - t:­ Ff 1 71 All permits must be reviewed, stamped, and approved PRIOR TO BEGINNING WORK. ❑ Alarm - New & Modification (minimum charge) $280 ❑ Over 10,000 sq ft $0 .028 x sq ft • Sprinkler - New & Modification (minimum charge) $280 ❑ Over 10,000 sq ft $0 .028 x sq ft • Minor Sprinkler Modification ( <10 heads) $96 (inspection only) 84 ❑ Commercial Hood (New & Modification) $470 ❑ Additional hood INFORMATION LOCATION OF PROJECT _ PROPERTY OWNER Developmental Services Support Foundation for Kern, 3300 N. Sillect Ave.. Bakersfield. CA 93308 Invo, & Mono. Counties STARTING DATE COMPLETION DATE NAME Jerry Bowman, Chief Financial Officer 6/10/10 6/13/10 Tent # PROJECrNAME ADDRESS PHONE # Kern Regional Center 3200 N. Sillect Ave. (661) 852 -3302 PROJECT ADDRESS cm g�F ' EP SF1 EL s sTArE CA ZIP CODE 3300 N. Sillect Ave.. Bakersfield. CA 93308 Aboveground Storage Tank (Removal, Mod,or Inspect'n) ATR 93308 CONTRACTOR INFORMATION 82 ❑ CONTRA( -rr)R NAMF CA LICENSE # TYPE OF LICENSE EXPIRATION DATE PHONE # Josh Slayton 481999. B 10/31/11 (661)327-1 436 CONTRACTOR COMPANY NAME FAX # Wallace& Smith Contractors (661) 327 -8865 ADDRESS CITY ZIP CODE 3325 Landco Dr. I Bakersfield, CA 93308 All permits must be reviewed, stamped, and approved PRIOR TO BEGINNING WORK. ❑ Alarm - New & Modification (minimum charge) $280 ❑ Over 10,000 sq ft $0 .028 x sq ft • Sprinkler - New & Modification (minimum charge) $280 ❑ Over 10,000 sq ft $0 .028 x sq ft • Minor Sprinkler Modification ( <10 heads) $96 (inspection only) 84 ❑ Commercial Hood (New & Modification) $470 ❑ Additional hood $58 ❑ Spray Booth (New & Modification) $470 . 82 98 Tent # Aboveground Storage Tank (1 inspection per installation) AST 180 /tank ( /`/( e $180 82 ❑ Additional Tank ATI $96 /tank 82 ❑ Aboveground Storage Tank (Removal, Mod,or Inspect'n) ATR $109 /tank 84 82 ❑ Underground Storage Tank (Installation /Inspection) NI $878 /tank 84 82 ❑ Underground Storage Tank (Modification) MOD $878 /site 84 82 ❑ Underground Storage Tank (Minor Modification). MTM $167 /site 84 82 ❑ Underground Storage Tank (Removal) TR $573 /tank 84 84 ❑ Mandated Leak Detection (test) /Fuel Mont Cert/SB989 NOTE: $96 /hr for each type of test/per site even if $96 /hr (2 hrs minimum) =$192 84 82 FD2021 (Rev 04/101 scheduled at the same time TT ❑ Oil well (Installation, Inspection, or re- inspection) X $96 /hr 82 • Tent # $96 /tent 84 • After -hours inspection fee $121 /hr (2 hrs minimum) -$242 ❑ Pyrotechnic (i permit per event, plus an inspection fee of $96 /hr during business hours) PY NOTE: After, hours, Pyrotechnic event inspection is @ $121/hr $96 /hr + (5 hrs min standby fee /insp) =$576 5 hrs min standby fee ins = 605 84 • Re- inspection /Follow -up Inspection $96 /hr 84 • Portable LPG (Propane): # of Cages? _ $96 /hr 84 • Explosive Storage $266 84 ❑ Copying & File Research (File Research fee $50 /hr) $0.25 /page 84 ❑ 1 Miscellaneous 84 FD2021 (Rev 04/101 CONSTRUCTION PERMIT BAKERSFIELD FIRE DEPARTMENT PREVENTION SERVICES E E R S F I D 1501 TRUXTUN AVENUE, 1sT FLR FIRE BAKERSFIELD, CA 93313 ARTM T Office Phone: (661) 326 -3979 Application Number . . . . . Property Address . . . . . . ATN (11 Digits) : Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Application valuation . . . . Owner ------------------ - - - - -- 10- 10000160 Date 5/28/10 3300 SILLECT AVE FIRE DEPT 0 Contractor ------------------ - - - - -- OWNER ---------------------------------------------------------------------------- Permit . . . . . . ABVGRND STR TANK (1 INSP /INST) Additional desc . Phone Access Code 1005396 Permit'Fee . . . . 90.00 Plan Check Fee 90.00 Issue Date . . . . 5/28/10 Valuation . . . . 0 Expiration Date . . 11/24/10 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --- -- ------ - - - - -- ---- - - - - -- -- -- - - - - -- ---- - - - - -- ---- - - -- -- Permit Fee Total 90.00 90.00 .00 .00 Plan Check Total 90.00 90.00 .00 .00 Grand Total 180.00 180.00 .00 .00 CALL FOR INSPECTION (661) 326 -3979 Please state the Permit Number, the Job address, and the Type of Inspection. Requests for inspections should be made at least 48 hours in advance. DECLARATIONS Permit is issued in accordance with all applicable Federal, State and Local Ordinances. The permittee has properly signed and dated the reverse side of this form. This Permit expires after180 days of inactivity. I have reviewed the above application, and find it to be correct/complete. Permittee: Date: HAZARDOUS MATERIALS STATEMENT Yes _ No Will the applicant or future occupant handle hazardous material or a mixture containing a hazardous material equal to or greater than the amounts specified on the list of extremely hazardous substances? See checklist for guidelines. Yes _ No Will the proposed building or modified facility be within 1000 feet of the outer boundary of a school? _ Yes _ No Will the intended use of the building by the applicant or future building occupant require a permit for construction or modification from the Kern County Air Pollution Control District ( KCAPCD) or from the Bakersfield Fire Dept? See checklist for guidelines. Yes _ No I have read the Hazardous Material Guide and KCAPCD Permitting Checklist. I understand my requirements under the Calif. Health and Safety Code Sec. 6.95 and Calif. Govt. Sec. 65850 and.the requirements of the City of Bakersfield Fire Dept. regarding hazardous materials. Owner or Authorized Agen �= ' "} " hone No. _ Date DECLARATIONS: The declarations below are mandated by the State of California under Section 19825 of the Health and Safety Code. LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of the Division 3 of the Business and Professions Code and my license is in full force and effect. Lic. Class Lic. No. Exp. Date Contractors Signature _ Date OWNER- BUILDER DECLARATION I hereby affirm that under penalty of perjury that I am exempt from the Contractors License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors License Law (Chapter 9 commencing with Section 7000 of Division 3 or the Business and Professions Code) or that he or she is exempt there from and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)): I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044 Business and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or herself through his or her own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner - builder will have the burden of proving that he or she did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044 Business and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves thereon and who contracts for such project with a contractor(s) licensed pursuant to the Contractor License Law). I am exempt under Sec. B. & P. C. for the reason Owner Signature -- e-.71�a X_" � _ -��� �. �= °�.• � . �`� � : � ���., � � tt _ *Date WORKERS COMPENSATION DECLARATION I hereby affirm that under penalty of perjury one of the following declarations: Carrier I have and will maintain a certificate of consent to self- insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Policy No. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code. I shall forthwith comply with those provisions. Applicant: Date WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000) IN ADDITION TO COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST AND ATTORNEY'S FEES CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097 Civ. C.) Lenders Name Lenders Address 1 certify that I have read this application and state that the information contained herein is correct. I agree to comply with all city ordinances and state laws relating to building construction and hereby authorize representatives of the city to enter the above mentioned - property for inspection purposes. Signature of Applicant or Agent ='°P - W"s a . >_�r '.I Date 07/09/2009 12:41 6613275419 Quotation MUM. Project: Date BM.Of materials Pacific Power Kern Regional Center Detail Information i azerinflon PAGE 09 QM57153 -GA1 ,I ' 60REOZ3C, 12V, 50Hz, 4P,. EPA Tier 3 Certified GMSB&5$ -KA2 I Enclosure, Weather,Crit 511,41" GM57156 -MA7 i Skid / Tank, 41 ", 120 Gallon, 4P8 226203 1 inner Tank Leak Alarm GM41692•-KPi I High Fuel Alarm GM57159 -MA8 1 Alternator, 4138 333708 GM55372-MAI 1 Z Vpitage,6OHz ,277 /48OV,Wye,.3Fh,4W,0.8PF Radiator, Unit Mtd. Cooling, 50C 222661 1 nameplate Rating, Standby 130 Degree GM19874 -KM i Decal, UL2200 Usting (Diesel) CGM57157 -MAi x Control 8% Harness - Dec 3+ 326237 1 Air Cleaner Restriction Indicator GM58099 -KA1 1 Vent, Closed Crankcase GM7.9979 -KA1 1 Rodent Guards,Non CSA,4P GM28525-KAi 1 0-661 -ant in Genset 5 gals. GM60041-KAI I Flexible Fuel Unes 258811 1. Power Factor Tesk,0.8,3Ph Only CiR x. Certifled Test Report GM55375 -MA2 1 Ali, Intake, Heavy Duty - 60kw GM55367 -KA3 1 Safeguard Breaker 256985 1 8attery,1 /12V,650CC4,Wet GM28569 -KAI 1 Batt Chgr, Float,, 90 -12OV, 12V -6A 273743 :1 Run Relay, 12V 347274 ! Failure RetaV w /Harness,1Fault(RESTRT•CT) CM58098 -KA1 I Heatar, Flock 364502 -MA132 1 Controller, 16 Ught,Dec3 +,12V1250A GM32644 -KA2 GM62516-KPI 1 1 Communication Module, 1601 ht Controller RSA 1H, ATS Annunciator GM52287 -KA1 1 LC (3, 104A, HDL, Therm. Mag, 800 /0 GM25953 -KAI I Dry ContactsJOSPOT,10 A MCDlCn�4.6� 1 KC'T -,,B+ TC- 104 Amp, .A77 /48OV 3 P6112 i'� oma 3P. ATS Wsirranty_ 1.. .01045, b WeYear Kohler 1.7actory Standard 2000 Hour Warr"nty 12 :24 PM SoM Only -Kern Reg'I Ctr- BOREOZJO,xis 71912009 I �Cicy of BAaersfieid a LUaii1 E f PUEIPT, ` �tPa. M, (I F 0RB .. 7YPe C1G. lira er 4 i "gate .�I 8144 �4 Receipt Descr i.pt? on Gant ty: , nat lr�4 rbIG 44;8 460 i BUILOW3 PEM4175 fe;i �2r Ma l CK [:4;C(K X449 f) cal_ te11der .,ed'1_ fi4 &0. fYe�S .'dace; i L.P (ZIN'Ri]L THE PET POPULATION pLER3E Sppy OR ht TER , 5; ; R Model: 60REOZJC KOHLERPOWER SYSTEMS 208 -600 V Dlesel 09001 Standard Features n� NATIONALLY REGISTERED - •. Kohler Co. provides one - source responsibility for the Ratings Range generating system and accessories. • Th nerator set and its com onents are 60 Hz Standby: kW 49 -60 WA 49 -75 Prime: kW 45 -54 WA 45 -68 Generator Set Ratings e ge p prototype- tested, factory- built, and production- tested. • The 60 Hz generator set offers a UL 2200 listing. • The generator set accepts rated load in one step., • The 60 Hz generator set meets NFPA 110, Level 1, when equipped with the, necessary accessories and Installed per NFPA standards. • The generator set complies with ISO 8528 -5, Class G2, requirements for transient performance in all generator set configurations. Select the Decision- Maker® 550 controller for improved voltage regulation and ISO 8528 -5, Class G3, compliance. • The 60 Hz generator set engine is certified by the Environmental Protection Agency (EPA) to conform to Tier 3 nonroad emissions regulations. • A one -year limited warranty covers all systems and components. Two -, five -, and ten -year extended warranties.are also available. - • Alternator features: • The unique Fast - Response- II excitation system delivers excellent voltage response and short- circuit capability using a permanent magnet (PM)- excited alternator. • The brushless, rotating -field alternator has broadrange reconnectability. • Other features: o Controllers are available for all applications. See controller features Inside. o The low coolant level shutdown prevents overheating (standard.on radiator models only). o Integral vibration Isolation eliminates the need for under -unit vibration spring isolators. RATINGS: Al three -phase units are rated at 0.8 power factor. Al single -phase units are rated at 1.0 power factor. Standby Ratings:. Standby ratings apply to installations served by a reliable utility source. The, stendby rating is eppticable tovarying loads for the duration of a power outage. There is go erload capebtiity icr this rating. Rat ns are in accordance with ISO.3046/BS 5514, AS 278d DN 8271. Prkne PrRetings: Primpngs ply tc Installations where utll ty punalr unreliable. At varying load, the number of tor st png hours is untiMted. A 10oad capadty la for one hour In twelve. Ratlngs ere In accordane with ISO 9528 /1, avedoad r In exordence with ISO 3048/1, BS 5514, AS 2789, and DIN 6271. For Ilmfted running timend base loaratlnga, osuR the factor Obtain the technical information bulletin (rIB-101) on ratlngs guids for the complete ratings defnitions. The generator set manufacturer reserves the right to change the design or specificall. without no0ce and without any obligation or 0ability whatsoever. GENERAL GUIDELINES FOR DERATION: ARi7ude: Derete 0.596 per 100 m (328 ft) elevation above 2300 m (7548 ft.). Temperature: Derate 1.0%per 10 °C (19 °� temperature above 25 °C (77 'G5 -317 (BOREOZJC) 9/09c 130 °C Rise 105 °C Rise Standby Rating Prime Rating Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps 120/208 3 60 60175 208 54/68 187 127/220 " 3 60 60/75 197. 54/68 • 177 120/240 3 60 60[75 180 54/68 162: . 120/240 1 60 49/49 204 45/45 188 4P8 139/240 3 60 60/75 180 54/68 162 220/380 3 60 55/69 104 50/63 95 • 277/480 3 60 60/75 90 54/68 81 347/600 3 60 50/63 60 45/56 54 120/208 3 60 60/75 208 54/68 187 127/220 3 .60 60/75 197 54/68 177 120/240 3 60 60/75 ,_ 180 54/68 162 120/240 1 60. 54/54 225. 50/50 208 4P10 139/240 3 60 60/75 180 54/68 162 220/380 3 60 60/75 114 54/68 103 277/480 3 60 60 [75 90 54/68 81 347/600 3 60 60175 72 53/66 64 4V7 120/240 1 60 57/57 238 51/51 213 e ge p prototype- tested, factory- built, and production- tested. • The 60 Hz generator set offers a UL 2200 listing. • The generator set accepts rated load in one step., • The 60 Hz generator set meets NFPA 110, Level 1, when equipped with the, necessary accessories and Installed per NFPA standards. • The generator set complies with ISO 8528 -5, Class G2, requirements for transient performance in all generator set configurations. Select the Decision- Maker® 550 controller for improved voltage regulation and ISO 8528 -5, Class G3, compliance. • The 60 Hz generator set engine is certified by the Environmental Protection Agency (EPA) to conform to Tier 3 nonroad emissions regulations. • A one -year limited warranty covers all systems and components. Two -, five -, and ten -year extended warranties.are also available. - • Alternator features: • The unique Fast - Response- II excitation system delivers excellent voltage response and short- circuit capability using a permanent magnet (PM)- excited alternator. • The brushless, rotating -field alternator has broadrange reconnectability. • Other features: o Controllers are available for all applications. See controller features Inside. o The low coolant level shutdown prevents overheating (standard.on radiator models only). o Integral vibration Isolation eliminates the need for under -unit vibration spring isolators. RATINGS: Al three -phase units are rated at 0.8 power factor. Al single -phase units are rated at 1.0 power factor. Standby Ratings:. Standby ratings apply to installations served by a reliable utility source. The, stendby rating is eppticable tovarying loads for the duration of a power outage. There is go erload capebtiity icr this rating. Rat ns are in accordance with ISO.3046/BS 5514, AS 278d DN 8271. Prkne PrRetings: Primpngs ply tc Installations where utll ty punalr unreliable. At varying load, the number of tor st png hours is untiMted. A 10oad capadty la for one hour In twelve. Ratlngs ere In accordane with ISO 9528 /1, avedoad r In exordence with ISO 3048/1, BS 5514, AS 2789, and DIN 6271. For Ilmfted running timend base loaratlnga, osuR the factor Obtain the technical information bulletin (rIB-101) on ratlngs guids for the complete ratings defnitions. The generator set manufacturer reserves the right to change the design or specificall. without no0ce and without any obligation or 0ability whatsoever. GENERAL GUIDELINES FOR DERATION: ARi7ude: Derete 0.596 per 100 m (328 ft) elevation above 2300 m (7548 ft.). Temperature: Derate 1.0%per 10 °C (19 °� temperature above 25 °C (77 'G5 -317 (BOREOZJC) 9/09c • Alternator Specifications Specifications Alternator a -NEMA MG1, IEEE, and ANSI standards compliance for Manufacturer Kohler temperature rise and motor starting. Type 4- Pole, Rotating -Field e. Sustained short - circuit current of up to 300% of the rated Exciter type Brushless, Permanent- Magnet current for up to 10 seconds. Leads: quantity, type 12, Reconnectable . Sustained short- circuit current enabling downstream circuit Voltage regulator Solid State, Volts/Hi breakers to trip without collapsing the alternator field. Insulation: NEMA MGi. a Self- ventilated and dripproof construction: Material Class H Temperature rise 130 °C, Standby a Vacuum- impregnated windings with fungus- resistant epoxy. Bearing: quantity, type 1, Sealed varnish for dependability and long life. Coupling Flexible Disc a Superior voltage waveform from a.two- thirds pitch stator and Amortisseur,windings Full skewed rotor. Voltage regulation, no-load to full -load a Fast - Response"' II brushless alternator with brushless' Permanent magnet (PM) alternator t2'/° Average exciter for excellent load response. 550 controller (with 0.5% drift due to temperature variation) 3 -Phase Sensing, x0.25% One -step load acceptance ; 100% of Rating Unbalanced load capability 100% of Rated Standby Current Peak motor starting kVA: (35% dip for voltages below) 480 V 4P8 (12 lead) 212 480 V 4P10 (12 lead) ' " 250 240, V 4V7 (4 lead) 215 Application Data Engine Engine Electrical Engine Specifications E11§166 Electtrdbl °System Manufacturer John Deere Battery charging alternator: Engine model 5030HF285G Ground (negative/positive) Negative Engine type 4- Cycle, Turbocharged, Volts (DC) 12 Cylinder arrangement 5lnline Ampere rating 70 Displacement, L (cu. in.) 3.0(186) Starter motor rated voltage (DC) 12 Bore and stroke, mm (in.) 86 x 105 (3.39 x 4.13) Battery, recommended cold cranking Compression ratio 18.2:1 amps (CCA): Piston speed, m /min. (ft. /min.) 375 (1230) Quantity, CCA rating One, 640 Main bearings: quantity, type 6, Replaceable Insert,.. - Battery voltage (DC) 12 Rated rpm 1800 Fuel Max. power at rated rpm, kWm (BHP) 72 (97) . Cylinder head material Cast Iron Fuel System Crankshaft material Ductile Iron Fuel supply line, min. ID, mm (in.). 11.0 (0.44) Valve material: Fuel return line, min. ID, mm (in.) 6.0 (0.25) Intake Chromium- Silicon Steel Max. lift, engine - driven fuel pump, m (ft.) 3.0 (10.0) Exhaust Stainless Steel" Max. fuel flow, Lph (gph) 82 (21.7) Governor: type, make /model JDEC Electronic, Fuel prime pump Manual Level 18, EUP Fuel filter Frequency regulation, no -load to full -load isochronous Secondary 5 Microns @ 98% Efficiency Frequency regulation, steady state *0.25% Water Separator Yes Frequency Field- Convertible Recommended fuel #2 Diesel Air cleaner type, all models Dry -Lubrication Exhaust Lubricating System , Exhaust System Type Full Pressure Exhaust manifold type Dry Oil pan capacity, L (qt.) 10.4 (11.0) Exhaust flow at rated kW, m3 /min. (cfm) 13.8 (488) Oil pan capacity with filter, L (qt.) 11.3 (11.9) Exhaust temperature at rated kW, dry Oil filter: quantity, type 1, Cartridge exhaust, °C ( °F) 524 (976) Oil cooler Water- Cooled Maximum allowable back pressure, kPa (in. Hg) 7.5 (2.2) Exhaust outlet size at engine hookup,, mm ((n.) `64.0 (2.5) G5 -317 (60REOZJC) 9/09c Application Data Cooling Radiator System Ambient temperature, °C ( °F)* 50 (122) Engine jacket water capacity, L (gal.) 3.4 (0.9) Radiator system capacity, including 96 (3400) engine, L (gal.) 11.0(2.9)- Engine jacket water flow, Lpm (gpm) 98 (26) Heat rejected to cooling water at rated 15.5 (880) kW, dry exhaust, kW (Btu /min.) 45.9 (2612) Heat rejected to air charge cooler at 17.5 (4.6) rated kW, dry exhaust, kW (Btu /min.) 13.0 (740) Water pump type Centrifugal Fan diameter, Including blades, mm (In.) 597 (23.5) Fan, kWm (HP) 4.1 (5.5) Max. restriction of cooling air, intake and discharge side of radiator, kPa On. H2O) 0.125 (0.5) * Enclosure reduces ambient temperature capability by 5°C (9 °F). Operation Reaulrements Air Requirements Radiator- cooled cooling air, Standby Rating m3 /min. (scfm)$ 96 (3400) Combustion air, m3 /min. (cfm) 5.3(187) Heat rejected to ambient air: 10.1. (2.7) Engine, kW (Btu/min.) 15.5 (880) Alternator, kW (Btu /min.) 8.9(505) $ Air density =1.20 kg /m3 (0.075 Ibm/ft3) 17.5 (4.6) Fuel Consumption Diesel, Lph (gph) at % load Standby Rating 100% 19.1 (5.0) 75% 14.4 (3.8) 50% 10.1. (2.7) 25% 6.0 (1.6) Diesel, Lph (gph) at % load Prime Rating 100% 17.5 (4.6) 75% 13.1 (3.5) 50% 9.2 (2.4) 25% 5.8 (1.5) Controllers L 0 oao,., 000� FIM! 'yam_' Decision- Maker° 550 Controller Audiovisual annunciation with NFPA 110 Level 1 capability.. Programmable microprocessor logic and, digital display features. Alternator safeguard circuit protection. 12- or 24 -volt engine electrical system capability. Remote start, remote annunciation, and remote communication options. Refer to G6 -46 for additional controller features and accessories. MENI Decision- Maker® 3 +, 16 -Light Controller Audiovisual annunciation with NFPA 110 Level 1 capability. Microprocessor logic, AC meters, and engine gauge features. 12- or 24 -volt engine electrical system capability. Remote start, prime power, and remote annunciation options. Refer to 66 -30 for additional controller features and accessories. Gs-317 (60REOZJC) 9/09c KOHLER CO., Kohler, Wisconsin 53044 USA Kohler Power Systems Phone 920- 565 -3381, Fax 920 -459 -1646 Asia Pacific Headquarters For the nearest sales and service outlet In the 7 Jurong Pier Road US and Canada, phone 1- 800 - 544 -2444 Singapore 619159 KohlerPower.com Phone (65) 6264 -6422, Fax (65) 6264 -6455 Additional Standard Features • Alternator Protection (standard with 550 controller) • Battery Rack and Cables Oil Drain and Coolant Drain w/Hose Barb • Oil Drain Extension (with narrow skid and enclosure models only) • Operation and Installation Literature • Radiator Drain Extension (with enclosure only) Available Options Approvals and Listings ❑ CSA Approval ❑ IBC Seismic Certification ❑ UL2200 Listing Enclosed Unit ❑ Sound Enclosure (with enclosed critical silencer) ❑ Weather Enclosure (with enclosed critical silencer) ❑ Weather Housing (with roof - mounted critical silencer) Open Unit ❑ Exhaust Silencer, Critical (kit: PA- 324470) ❑ Exhaust Silencer, Hospital (kit: GM32386 -KP1) ❑ Flexible Exhaust Connector, Stainless Steel Fuel System ❑ Auxiliary Fuel Pump ❑ Flexible Fuel Lines ❑ Fuel Pressure Gauge ❑ Subbase Fuel Tanks Controller ❑ Common Failure Relay ❑ Communication Products and PC Software (550 controller only) ❑ Customer Connection ❑ Dry Contact (Isolated alarm) ❑ Engine Prealarm Sender (16 light controller only) ❑ Prime Power Switch (550 controller only) ❑ Remote Annunciator Panel ❑ Remote Audiovisual Alarm Panel ❑ Remote Emergency Stop ❑ Remote Mounting Cable ❑ Run Relay Cooling System ❑ Block Heater; Recommended for Ambient Temperatures Below 0 °C (32 °F) ❑ Radiator Duct Flange Electrical System ❑ Alternator Strip Heater ❑ Battery ❑ Battery Charger, Equalize/Float Type ❑ Battery Heater ❑ Line Circuit Breaker (NEMA type 1 enclosure) ❑ Line Circuit Breaker with Shunt Trip (NEMA type 1 enclosure) ❑ Safeguard Breaker (not available with 550 controller) Paralleling System • Reactive Droop Compensator • Remote Speed Adjust Control/Electronic Governor ❑ Voltage Adjust Control ❑ Voltage Regulator Relocation Miscellaneous ❑ Air Cleaner, Heavy Duty ❑ Air Cleaner Restriction Indicator ❑ "Closed Crankcase Vent ❑ Engine Fluids (oil and coolant) Added ❑ Rated Power Factor Testing ❑ Rodent Guards ❑ Skid End Caps Literature ❑ General Maintenance ❑ NFPA 110 ❑ Overhaul' ❑ Production Warranty ❑ 2 -Year Basic ❑ 2 -Year Prime ❑ 5 -Year Basic ❑ 5 -Year Comprehensive ❑ 10 -Year Major Components Other Options Dimensions and Weights Overall Size, L x W x H, mm (in.): Wide Skid: ' 2300 x 1040 x 1133 (90.55 x 40.94 x 44.61) Narrow Skid: 1998 x 780 x 1067 (78.66 x 30.71 x 42.61) Weight (radiator model), wet, kg (lb.): . 892 (1966) �r L NOTE: This drawing Is provided for reference only and should not be used for planning Installation. Contact your local distributor for more detailed Information. DISTRIBUTED BY: ® 2008, 2009 by Kohler Co. All rights reserved. t35 -317 (60REOUG) 9 /09c Model KCT /KCP KOHLERPOWER SYSTEMS Transfer Automatic 90.01 MPAC 1000'M Controller Standard Features NATIONALLY REGISTERED Ratings Voltage: 208 -600 VAC 50/60 Hz Current: Open - Transition: 30 -4000 amps Programmed- Transition: 150 -4000 amps Standard Contactor Features, • Open- transition or programmed- transition modes of operation with either automatic or non - automatic control • 2, 3, or 4 poles • Electrically operated, mechanically held • Double- throw, inherently Interlocked design (break - before -make power contacts) • Solid, switched, or overlapping neutral (make- before -break type) • High withstand and closing ratings • Design suitable for emergency and standby applications on all classes of load, 100% tungsten rated through 400 amps . • Open - transitlon transfer time less'than 100 milliseconds (6 cycles @.60 Hz) • Silver alloy main contacts • Front - accessible contacts for easy inspection • Front - replaceable main and arcing contacts (600 -4000 amps) • Reliable, field - proven solenoid mechanism • Switching mechanisms lubricated for life • Internal manual operating handle • Main shaft auxiliary contacts Modbuse is a registered trademark of Schneider Electric. • Microprocessor controller • Real -time clock with battery, backup • Broadrange voltage sensing (208 -600 VAC) with 2% accuracy on both sources • . Frequency sensing with 1 % accuracy on both sources • Environmentally sealed user Interface • Keypad with tactile feedback pushbuttons • LED indicators • Selectable operating modes • Programmable inputs and outputs • Load /no load exercise function • Anti- single phasing protection • Load control. Inputs and outputs • Phase rotation sensing • Time- stamped event log • Gold- flashed engine start contacts 9 Modbus® communication with network and setup connections MPAC 1000"m Controller Programmable Features • System voltage and frequency. • Adjustable over /undervoltage and over /underfrequency for the normal and emergency sources • Adjustable time delays • Commit/no commit transfer • ABC/BAC phase rotation selection with error detection • Resettable historical data • In -phase monitor • Password protection Accessories • Programmable Input/output (1 /0) modules with two Inputs _ and six outputs (Isolated SPDT form C contacts, output rating 2 amps @ 30 VDC /250 VAC); four 1/0 module maximum . • Three -stage charging, dual- output battery charger (6 amps @ 12 VDC /3 amps @ 24 VDC) • Padlockable user interface cover • Preferred source switch • Supervised transfer control switch • Setup software • Load shed (forced transfer from Emergency to Off; programmed- transition models only) • Line -to- neutral monitoring • Chicago alarm module • External battery supply module (allows extended engine start time delay) G71- 80 (Model KCT/KCP Transfer SWtch) 1P/04m Controller Features Standard Controller Features User Interface Keypad • Start/end system test • Set/end exercise • End time delay • Lamp test/service reset User Interface Indicators • Contactor position: Normal, Off, Emergency • Source available: Normal, Emergency • Service required: immediate, maintenance • Not in automatic mode • Four -stage time delay remaining • Exercise: load, no load, set/disabled . • Test: load, no load • Load control active: peak shave, load shed, . pre /post- transfer signal. • In -phase monitor active Selectable.Operating Modes* • 1 week/2 week manually set exercise (1 week) • Disable /enable exercise (enable) • Load /no load exercise (no load) • Load /no load test (load) • Enable /disable transfer (enable) Programmable Inputs (factory settings) • End time delay • Peak shave /area protection Outputs • Generator engine start, normally closed gold - flashed contact rated 2 amps @ 30 VDC /250 VAC • Pre- transfer load control, one normally open contact rated 10 amps @ 30 VDC /250 VAC • One programmable output, factory-set to load bank control isolated SPDT form C contact rated 2 amps @ 30 VDC /250 VAC Software Event.Monitoring Use a personal computer with the optional setup software or a Modbus® link to view historical data and system events. • Historical data (total and resettable) • System events (time and date - stamped) • System faults (time and date- stamped) • Line -to -line voltage • System frequency • Time delay active • Time delay remaining • System status • Source available • Contactor position • Exerciser schedule, mode,.and time remaining on active exercise * Factory default settings- are shown in parentheses. All settings are stored In non - volatile memory. t System parameters set per order. Communications • Serial port for PC connection • Modbus® network Interface Programmable Features Use a personal computer with the optional setup software or a Modbuse link to view, select, or adjust programmable features. Programmable Features* • System voltaget • System frequencyt • Singie/three -phase operationt • Open /programmed - transition operation t: • ABC or CBA phase rotation (ABC) • In -phase monitor (disabled) • Commit/no commit switch (no commit) • User - defined password • Calendar mode exerciser (up to 21 events) Programmable Inputs and Outputs Use a personal computer with the optional setup software or a Modbus® link to define Inputs and outputs. . Programmable Inputs • End time delay input (default) • Inhibit transfer • Low battery fault • Load shed (forced transfer to OFF; programmed - transition models only) • Peak shave /area protection input (default) • Remote common fault - • Remote test Programmable Outputs • Auxiliary switch fault • Common fault • Contactor position • Exercise active • Failure to acquire standby source • Failure to transfer fault • Generator engine start • Load bank control (default) . • Load control (pre /post transfer, up to 9 outputs) • Loss of phase fault • Low backup battery • Modbus®- controlled relay outputs (4 maximum) • Not In automatic mode • Non - emergency transfer • Over and undervoltage faults. • Over and underfrequency faults .• Peak shave /area protection active • Phase rotation'error • Source available • Test active 011 -80 (Model KCT/KCP Transfer Switch) 12/04m Controller Features, continued . Application Data Voltage and. Frequency Sensing Parameter Default Adjustment Range Undervoltage pickup 90% of nominal 85% -100% of nominal Undervoltage dropout 90 %.of pickup 75 % -98% of pickup Overvoltage dropout 115% of nominal 105 % -135% of nominal* Overvoltage pickup 95% of dropout 95% -100% of dropout Voltage dropout time 0.5 sec. 0.1 -9.9 sec. Underfrequency pickup 90% of nominal 85 % -95% of nominal Underfrequency dropout 99% of pickup 95 % -99% of pickup Overfrequency.dropout 101% of pickup 101% -105% of pickup Overfrequency pickup 110% of nominal 105% -120% of nominal Frequency dropout time 3 sec. 0.1 -15 sec. * 690 volts, maximum Adjustable Time Delays Time Delay Default Adjustment Range Engine start 3 sec: 0 -6 sec. - Preferred to standby 1 sec. 0 -60 mina Standby to preferred 15 min. Engine cooldown. 0 min. Failure to acquire standby source 1 min. Pretransfer to preferred signal 3 sec. Pretransfer to standby signal 3 sec. Post - transfer to preferred signal 0 sec. Post - transfer to standby signal 0 sec. Off to standby . (programmed - transition only) 1 sec. .Off to preferred (programmed - transition only) 1 sec. t Adjustable in 1 second Increments. Can be extended to 60 minutes with an External Battery Supply Module Kit. UL- Listed Solderless Screw -Type Terminals for External Power Connections Normal, Emergency, and Load Terminals Switch Rating (Amps) Maximum Number of Cables per Pole Range of Wire Sizes, Copper or Aluminum # 30 -230 KCT 1 #14 AWG to 4/0 AWG t 260 -400 KCT 1 #4 AWG to 600 MCM 2 #1/0 AWG to 250 MCM 150 -400 2 , 3 -pole KCP . 1 #4 AWG to 600 MCM 2 #1 /0 AWG to 250 MCM 150 -400 4 -pole KCP 2 #2 AWG to 600 MCM 600 2 42 AWG to 600 MCM 800 -1200 4 #1 10 AWG to 750 MCM 1600 -2000 6 #1 /0 AWG to 750 MCM 2600 -3000 12 #1 /0 AWG to 750 MCM 4000 Bus Bar $ 230 amp /600 volt use copper only Input and Output Connection Specifications Component Number of Wires Wire Size Range Terminal strip 1/0 terminals 1 #12 -24 AWG 1/0 module terminals 1 #14 -24 AWG Auxiliary Position Indicating Contacts (rated 10 amps @ 32 VDC /250 VAC) Switch Rating (Amps) Number of Contacts Indicating Normal, Emergency Open- Transition Programmed - Transition 30 -104 2,2 — 150 -400 2.2 2,2 150-400§ — 6,6 600 -800 2,2 6,6 1000 -3000 8,,8 7,7 4000 4,4 4,3 § Programmed - transition with switched neutral Environmental Specifications Operating Temperature -20 °C to 70 °C ( -4 °F to 158 °F) Storage Temperature -40 °C to 70 °C ( -40 °F to 158'F) Humidity 5% to 95% noncondensing Altitude 0 to 3050 m (10000 ft.) without derating G11 -80 (Model KCT /KCP Transfer Switch) 120m Codes and Standards The ATS meets or exceeds the.requirements of the following specifications: • Underwriters Laboratories UL 508, Standard for Industrial Control Equipment • Underwriters Laboratories UL 1008, Standard for Automatic Transfer Switches for Use in Emergency Standby Systems • Underwriters Laboratories Inc., listed to Canadian Safety Standards (cUL) • NFPA 70, National Electrical Code • NFPA 99, Essential Electrical Systems for Health Care Facilities • NFPA 110, Emergency and Standby Power Systems . • IEEE Standard 446, IEEE Recommended Practice for Emergency and Standby Power Systems for Commercial and Industrial Applications • NEMA Standard IC10 -1993 (formerly ICS2 -447), AC Automatic Transfer Switches • EN61000 -4 -5 Surge Immunity Class 4 (voltage sensing and programmable inputs only) • EN61000 -4 -4 Fast Transient Immunity. Severity Level 4 • IEC Specifications for EMI /EMC Immunity: o CISPR 11, Radiated Emissions o IEC 1000 -4 -2, Electrostatic Discharge • IEC 1000 -4 -3, Radiated Electromagnetic Fields • IEC 1000 -4 -4, Electrical Fast Transients (Bursts) • IEC 1000 -4 -5, Surge Voltage • IEC 1000 -4 -6; Conducted RF Disturbances • IEC 1000 -4 -8, Magnetic Fields • IEC 1000 -4 -11, Voltage Variations and Interruptions Withstand Current Ratings. (WCR) Open- and Programmed- Transition Models Maximum current in RMS symmetrical amperes when coordinated with customer - supplied fuses or circuit breakers. Withstand Current Ratings In RMS Symmetrical Amperes§ Any Circuit Breaker Specific Circuit Current - Limiting Fuses Breaker Switch Cycles Q Amps Q Amps Q Max. Amps Q Volts, Fuse Size, Rating, Amps 60 Hz 480 VAC 600 VAC 480 VAC Amps Max Amps Type . 30* 1.5 10,000 10,000 N/A 100,000 480 60 LPS -RK, 70* 104* 1.5 10,000 10,000 22,000 200,000 480 200 .150* 1501' 3 35,000 22,000. 42,000 200,000 480 450 200* 1.5 10;000 N/A 22,000 200,000 480 200 230* 1.5 10,000 22,000 22,000 100,000 480 300 2251' 260 3 35,000 22,000 42,000 200,000 480 600 " 400 600 3 50,000 50,000 800 1000 65,000 200,000 600 1600 1200 18 *" 36,000 36,000 1600$ 3 100,000 100,000 2000$ N/A 200,000 600 3000 30 ** 65,000 65,000 L . 2600 3 100,000 100,000 3000 N/A 200,000 600 4000 30 ** 65,000 65,000 3 100,000 100,000. 4000 N/A 200,000 480 6000 30 ** 65,000 65,000 * Open - transition models KCT only. t .Programmed- transition KCP models only. # Optional front - connected service limited to 85,000 amps for speciflc and any breaker ratings. § All values are available symmetrical RMS amperes and tested in accordance with the withstand and close -on requirements of UL 1008. Application requirements may permit higher withstand ratings for certain size switches. Contact Kohler Co. for assistance. ** Short time ratings.are provided for applications involving breakers that do not have Instantaneous trips for systems coordination. G11 -80 (Model KCT/KCP Transfer Switch) 12104m Ratings with Specific Manufacturers' Circuit Breakers The following charts list power switching device withstand current ratings (WCR) in RMS symmetrical amperes for specific manufacturers' circuit breakers. Circuit breakers are supplied by the customer. G11 -80 (Model KCT/KCP Transfer Switch) 12/04m Molded -Case Circuit Breakers Switch Rating, Amps WCR, Amps RMS Voltage, Max. Manufacturer Type Max. Size, Amps 70 * 22,000 480' Square D FH .80 FC, FI 100 KA, KC, KH, KI, LA, LH 250 GE TB1 100 TEL, THED, THLC1, THLC2 150 TFL 225 ITE CED6, ED6, HED4, HED6 125 CFD6 150 FD6, FXD6, HFD6 250 Cutler- Hammer FCL, Tri-Pac FB 100 FD, FDC, HFD 160 HJD, JD, JDB, JDC 250 HKD, KD, KDB, KDC, LCL, Tri -Pao LA 400 ABB S1 125 S3 150 Merlin Garin CE104, CE106 100 104 * 22,000 480 Square D FC, FI 100 KA, KC, KH, KI, LA, LH 250 GE 7131 100. TEL, THED, THLC1, THLC2 150 TFL 225 ITE CED6, ED6, HED4, HED6 125 CFD6 160 FD6, FXD6, HFD6 250 , Cutler- Hammer FCL, Td -Pac FB 100 FD, FDC, HFD 150 HJD, JD, JDB, JDC 250 HKD, KD, KDB, KDC, LCL, Tri-Pac LA 400 ABB Si 125 S3 160 Medin Garin CE104, CE108 100 CF250 250 150 * 22,000 480 GE TEL, THED, THLC1 160 TFL, THFK, THLC2 225 SFL, SFP, TFJ, TFK 250 SGL4, SGP4, TLB4 400 ITE CFD6, FD6, FXD6, HFD6 225 CJD6, HHJD6, HHJXD6, HJD6, JDB, JXD6, SCJD6, SHJD6, SJD6 400 Square D KA, KC, KH, KI 250 LC, LI 300 LA, LH. 400 Cutler- Hammer FD, FDC, HFD 150 HJD, JD, JDB, JDC 250 LCL, Tri -Pac LA, HKD, KD, KDB, KDC 400 ABB S3 160 Merlin Garin CF250 250 CJ400 400 1501' 42,000 480 GE TEL, THED, THLC1, 150 TFL,THLC2 225 SFL, SFLA SFP 250 SGL4, SGP4, TB4, THLC4, TLB4 400 SGLA, SGL6, SGP6, Tea 600 ITE CFD6, HFD8 250 CJD6, HHJD6, HHJX06, HJD6, SCJD6, SHJD6 400 CLD6, HHLDS, HHLXD6, HLD8, SHLD6 600 Square D KC, KI 250 LC, LI 400 Cutler- Hemmer HJD, JDC 250 LCL, Td -Pac LA, HKD, KDC 400 HLO 600 Tri -Pac NB 800 ABB IS3 , 150 Merlin Garin CF250 250 CJ400 400 * Open transition models KCT only t' programmed - transition models KCP only G11 -80 (Model KCT/KCP Transfer Switch) 12/04m Ratings with Specific Manufacturers' Circuit Breakers, continued Switch Molded-Case Circuit Breakers Rating, Amps WCR, Amps RMS Voltage, Max. Manufacturer Type Max. Size, Amps 200 * 230 * 22,000 480 GE TFL, THFK, THLC2 225 SFL, SFP, TFJ, TFK 250 SGL4, SGP4, TL134 400 ITE CFD6, FD6, FXDe, HFD6 225 CJD6, HHJD6, HHJXD6, HJD6, JD6, JXD6, SCJD6, SHJD6, SJD6 400 Square D. KA, KC, KH, KI 250 LC, LI 300 LA, LH 400 Cutler- Hammer HJD, JD, JDB, JDC 250 LCL, Tri -Pac LA, HKD, KD, KDB, KDC 400 Merlin Gerin CF250 250 CJ400 400 226t 260 42,000 480 GE TFL, THLC2 225 SFL, SFLA SFP 250 SGL4, SGP4, TB4, THLC4, TLB4 400 SGLA, SGLe, SGP6, TBe 600 SKHA, SKLB, SKP8, TKL 800 ITE CFD6, FD6, FXD6, HFD6 250 CJD6, HHJD6, HHJXD6, HJD6, JD6, JXDe, SCJDG, SHJD6, SJD6 400 CLD6, HHLD6, HHLXD6, HLD6, SCLD6, SHLD6 600 CMD6, HMD6, HND6, MDe, WOO, SCMD6, SHMD6, SMD6, SNDe 800 Square D KC; KI 250 LC, LI 600 MH 800 Cutler- Hammer HJD,JDC 250 HKD, KDC, LCL, Td -Pac LA 400 HLD 600 Td -Pac NB 800 ABB S5 400". S6 600 Merlin Gerin CF250 250 CJ400 400 400 42,000 480 GE SGL4, SGP4, T134, THLC4, TLB4 400 SGLA, SGL6, SGP6, T136 800 SKHA, SKLB, SKP8, TKL 800 ITE CJD6, HHJDe, HHJXD6, HJD6, SCJD6, -SHJD6 400 CLD6, HHJD6, HHLXDB, HLD6, SCLDe, SHLDB 600 CMD6, HMD6, HND6, MDe, WOO, SCMD6, SHMDS, SMDe, SND6 Soo Square D LC, LI 600 MH 800 Cutler- Hammer HKD, KDC, LCL, Tri -Pao LA 400 HLD 600 TH -Pac NB 800 ABB S5 400 S6 Boo Merlin Garin CJ600 '600 600 Boo 1000 65,000 480 GE TB8 800 Microversatrip TKL 1200 ITE CLDB, HHLDS, HHLDX6, HLD6, SCLDB, SHLDB 600 CMD6, HMD6, SCMD6, SHMD6 800 CND6, HND6, SCND6, SHND6 1200 CPD6 1600 Square D MH Series 2 1000 SE (LS Trip), SEH (LS Trip) 2500 1200 600 Cutler- Hammer Tri -Pac NB 800 Tri -Pac PB 1600 RDC 2500 42,000 480 ABB se Boo S7 1200 Merlin Garin CJ600 600 CK1200 1200 * Open - transition models KCT only t Programmed - transition models KCP only all -80 (Model KCT/KCP Transfer Switch) 12/04m Weights and Dimensions Weights and dimensions are shown for transfer switches in NEMA type 1 enclosures, type 3R enclosures, and open units. Consult the factory for NEMA type 12, 4, and 4X enclosures. Note: This Information is provided for reference only and should not be'used for planning Installation. Contact your local distributor for more detailed Information. Model Amps Poles NEMA Type Dimensions mm (in.) Weight kg (lb.) Height Width Depth 2 -Pole 3 -Pole 4 -Pole 30 -200 .2,3,4 1, 3R 791. (31) 450 (18) 314 (12.4)$ 28 (62) 30 (65) 31 (68) 230 -400 2,3,4 1, 3R 1223 (48) 560 (22) 362 (14.3)$ 52 (115) 56 (123) 59 (131) 600 -1000 2,3,4 1, 3R 1932 (76)* 864 (34) 515 (20.3)4 220 "(485) 231 (510) 238 (525) 1200 3,4 1 2286. (90) 963 (38) 686 (27) — 356 (785) 379 (835) 3,4 3R 2286 (90) 641 (25.2) 717 (28.2) — 356 (785) 379 (835) KCT Open- Transition 1600 -2000 3,4 1 2286 (90) 965 (38) 1220 (48) — 472 (1040) 494 (1090) 3,4 3R 2286 (90) 940 (37) 1434 (56.4) — 472 (1040) 494 (1090) 1600- 2000Ft 3,4 1 2286 (90) 963 (38) 688. (27) — 472 (1040) 494 (1090) 2600 -3000 3,4 1 2286_ (90) 963 (38) 1524 (60) — 649 (1430) 679 (1495) 3,4 3R 2286 (90) 641 (25.2) 1738 (68.4) — 649 (1430) 679 (1495) 4000 3,4 1 2286 (90) 1168 (46) 1829 (72) — 1043 (2300) 1089 (2400) 150 -400 2,3 1,3R 1702 (67)* 610 (24) 514 (20.2)t -179 (395) 183 (403) — 4 1,3R 1932 (76)* 864 (34) 515 (20.3)$ — — 238 (525) 600 -1000 2,3,4 1,3R 1932 (76)* 864 (34) 515 (20.3)t 220 (485) - 231 (510) 238 (525) KCP 1200 3,4 1 2286 (90) 965 (38) 686 (27) — 463 (1020) 485 (1070) 3,4 3R 2286 (90) 940 (37) 717 (28.2) — 463 (1020) 485 (1070) Programmed- Transition 1600 -2000 3,4 1 2286 (90) 963. (38) 1220 (48). — 533 (1175) 556(1225) _3,4 3R 2286 (90) 940 (37) 1434 (56.4) — 533 (1175) 556 (1225) 1600- 2000Ft 3,4 1 2286 (90) 963 (38) 688 (27) — 533 (1175) 556 (1225) 2600 -3000 3,4 1 2286 (90) 963 (38) 1524 (60) — 735(-1620) . 765 (1685) 3,4 3R 2286 (90) 940 (37) 1738 (68.4) — 735 (1620) 765'(1685) 4000 3,4 1 2286 (90) 1168 (46) 1829 (72) — 1115 (2457) 1160 (2557) KCT Open- Transition _ 30 -200 2,3,4 Open Unit § 787 (31) 445 (17.5) 296 (11.6) 8 (17) 9 (20) 11 (23) _ 230 -400 2,3,4 1.219 (48) 457 (18.0) 330 (13.0) 17 (37) 21 (45) — 600 -1000 2,3,4 1829 (72) 864 (34) 508 (20) 68 (150) 78 (170) 90 (196) 1200 2,3,4 2210 (87) 965 (38) 584 (23) 68 (150) 78 (170) 90 (196). 1600 -2000 3,4 2286 (90) 965 (38) 1219 (48) (420). 213 (470) 1600- 2000Ft j 3,4 2210 (87) 965 (38) 635 .(25) 2600 -3000 3,4 2286 (90) 965 (38) 1524 (60) — 213 (470) 243 (535) 4000- 3,4 2286 (90) 1168 (46) 1828 (72) — 545 (1200) 590 (1300) KCP Programmed- Transition 150 -400 2,3 Open Unit § 1600 (63) 610 (24) 445 (17.5) 20 (45) 24 (53) — 4 1829 (72) 864 (34) 1 508 (20) — — 108 (235) 600 -1000 2,3,4 1829 (72) 864 (34) 508 (20) 80 (175) 94 (205) 108 (235) 1200 2,3,4 2210 (87) 965 (38) 584 (23) 80 (175) 94.(205) 108 (235) 1600 -2000 3,4 2286 (90) 965 38) ( 1219 48 ( ) _ 252 (555) 274 (605) 1600- 2000Ft 3,4 2210 (87) ,965 (38) 635 (25) 2600 -3000 3,4 2286 (90) 965 (38) 1524 (60) — 300 (660) 329 (725) 4000 3,4 2286 (90) 1168 (46) 1828 (72) — 611 (1347) 657 (1447) *. Includes mounting feet t F =Front connected 4 On 30 -1000 amp models, the NEMA type 311 enclosures have a security cover on the controller that extends 54 mm (21 in.) beyond the door. § Dimensions shown for open units are the minimum required enclosure size. Open units weights are shipping weights for the contactor only. 011 -80 (Model KCT/KCP Transfer Switch) 1Z04m KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920- 565 -3381, Fax 920 -459 -1646 For the nearest sales and service outlet In the US and Canada, phone 1- 800 - 544 -2444 KohlerPowerSystems.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65)264 -6422, Fax (65)264 -6455 Record the transfer switch model designation In the boxes below. The transfer switch model designation defines characteristics and ratings as explained in the accompanying chart. Model Mechanism Transition Controls . Voltage Poles Enclosure Current Rating, Connections Kohler® Model Designation Key SAMPLE MODEL DESIGNATION This chart explains the Kohlerm transfer switch model designation system: The sample model designation shown Is for a Model K automatic transfer switch that uses an KCT w w .i w H 0400S open - transition contactor with MPAC 1000- electrical controls rated at 480 volts /60 Hz, - I � I 3 poles, 4 wires, and solid neutral in a NEMA 1 enclosure with a current rating of III I I I I I 400 amperes. Not all. possible combinations are available. Model K: Model K automatic transfer switch Mechanism C: Automatic B: Bypass Isolation (See G11 -81) N: Non - automatic Transition T. Open - Transition P: Programmed - Transition Electrical Controls A: MPAC 1000' (Microprocessor ATS Controls) Voltage/Frequency C: 208 Volts /60 Hz H: 400 Volts /50 Hz N: 600 Volts /60 Hz D: 220 Volts /50 Hz J: 416 Volts /50 Hz P: 380 Volts /60 Hz F: 240 Volts /60 Hz K: 440 Volts /60 Hz S: 220 Volts /60 Hz G: 380 Volts /50 Hz M: 480 Volts /60 Hz Number of Poles/Wires N: 2 -pole, 3 -wire, solid neutral Z: 3 -pole, 4 -wire, integral solid neutral T: 3 -pole, 4 -wire, solid neutral (Solid neutral mounted on the contactor. V: 4 -pole, 4 -wire, switched neutral Not available on all amperages.) W.4 -pole, 4 -wire, overlapping neutral Enclosure A: NEMA It C: NEMA 3R= F: NEMA 4X§ B: NEMA 12§ D: NEMA4§ G: Open unit t Standard on 30 -4000 A models. * Available to order on 30 -3000 A models. Contact the factory for 4000 A models. § Available to order on 30 -1000 A models. Contact the factory for larger. units. Current Rating: Numbers Indicate the current rating of the switch In amperes: 0030 0200(KCT) 0400 1200 2600 0070 0225 (KCP) 0600 1600 3000 0104 0230(KCT) 0800 2000 4000 0150 0260 1000 Power Connections S: Standard F: Front bus (available on 1600 and 2000 A models only) Availability Is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerm generator set distributor for avellability. 02001, 2002, 2003, 2004 by Kohler Co. MI rights resented. G71 -80 (Model KCT/KCP Transfer Switch) 12/04m DISTRIBUTED BY: Industrial Generator Set Accessories KOHLERWeatherlSound ®POW ER SYSTEMS ubba e. Fuel Enclosure and Subbase. Fuel Tank Package 09001 Appl icable icable tothe following: 4ru S5M 20- 60REOZJC NATIONALLY REGISTERED 230- 275REOZJE 20- 60REOZJC ac �c 0 0 20- 60REOZJC 230- 275REOZJE GB -99 7109g Pagel Weather Enclosure Standard Features • Internal- mounted critical silencer and flexible exhaust connector. • Lift base or tank - mounted, steel construction with hinged doors. • Fade -, scratch -, and corrosion - resistant Kohler® cream beige powder -baked finish. • Lockable, flush - mounted door latches. • Vertical air inlet and outlet hoods with 90 degree angles to redirect air and reduce noise. • High wind bracing, 241 kph (150 mph). Available with 20- 60REOZJC models only. Sound Enclosure Standard Features • Includes all of the weather enclosure features with the addition of acoustic insulation material. • Lift base or tank - mounted, steel or aluminum construction with hinged doors. Aluminum enclosures are recommended for high humidity and /or high salt/ coastal regions. • Acoustic Insulation that meets UL 94 HF1 flammability classification and repels moisture absorption. • Sound attenuated enclosure that uses up to 25 mm (1 In.) of acoustic insulation, acoustic -lined air inlet hoods, and acoustic -lined air discharge hood. Subbase Fuel Tank Features • The above - ground rectangular secondary containment tank mounts directly to the generator set, below the generator set skid (subbase). • Both the Inner and outer tanks have emergency relief vents. • Flexible fuel lines are provided with subbase fuel tank selection. • The secondary containment generator set base tank meets UL 142 tank requirements. The Inner (primary) tank is sealed inside the outer (secondary) tank. The outer tank contains the fuel If the inner tank leaks or ruptures. 0 0 230- 275REOZJE GB -99 7109g Pagel Weather Enclosure Standard Features • Internal- mounted critical silencer and flexible exhaust connector. • Lift base or tank - mounted, steel construction with hinged doors. • Fade -, scratch -, and corrosion - resistant Kohler® cream beige powder -baked finish. • Lockable, flush - mounted door latches. • Vertical air inlet and outlet hoods with 90 degree angles to redirect air and reduce noise. • High wind bracing, 241 kph (150 mph). Available with 20- 60REOZJC models only. Sound Enclosure Standard Features • Includes all of the weather enclosure features with the addition of acoustic insulation material. • Lift base or tank - mounted, steel or aluminum construction with hinged doors. Aluminum enclosures are recommended for high humidity and /or high salt/ coastal regions. • Acoustic Insulation that meets UL 94 HF1 flammability classification and repels moisture absorption. • Sound attenuated enclosure that uses up to 25 mm (1 In.) of acoustic insulation, acoustic -lined air inlet hoods, and acoustic -lined air discharge hood. Subbase Fuel Tank Features • The above - ground rectangular secondary containment tank mounts directly to the generator set, below the generator set skid (subbase). • Both the Inner and outer tanks have emergency relief vents. • Flexible fuel lines are provided with subbase fuel tank selection. • The secondary containment generator set base tank meets UL 142 tank requirements. The Inner (primary) tank is sealed inside the outer (secondary) tank. The outer tank contains the fuel If the inner tank leaks or ruptures. Weather and Sound Enclosure Fade -, scratch -, and Hinged doors Lockable, flush- Enclosed exhaust silencer Vertical air corrosion- resistant for ease of mounted door latches for Improved safety and discharge through powder -baked finish servicing prevent tampering noise reduction an air outlet grille ° ° ° °° a. ° J ° °� - -- ° ° ° ADV -7420- Alternator Rodent guards and skid Fixed air Oil drain Acoustic Insulation access end caps prevent flow inlet and radiator meeting UL 94 HF1 panel unwanted animal entry grille drains flammability classification Note: 20- 60REOZJC models shown, other models are similar. Refer to the respective ADV drawings for details. Enclosure Features • Available in steel (14 gauge) formed panel, solid construction. Preassembled package offering corrosion resistant, dent resilient structure mounting directly to lift base or fuel tank. • Powder -baked paint. Superior finish, durability, and appearance. • Internal critical exhaust silencer offering maximum component life and operator safety. • Interchangeable modular panel construction. Allows complete serviceability or replacement without compromising enclosure design. • Cooling /combustion air intake with a horizontal air inlet. Sized for maximum cooling airflow. • Service access. Multi- personnel doors for easy access to generator set control and servicing of the fuel fill, fuel gauge, oil fill, and battery. • Cooling air discharge. Weather protective design featuring a vertical air discharge outlet grille. Redirects cooling air up and above enclosure to reduce ambient noise. Additional Sound Enclosure Features • Available in steel (14 gauge) or aluminum 3.2 mm (0.125 in.) • Cooling air discharge. The sound enclosures include formed panel, solid construction. acoustic Insulation with urethane film. • Attenuated design. Acoustic Insulation UL 94 HF1 listed for flame resistance offering up to 25 mm (1 in.) mechanically restrained acoustic insulation. GS-99 7109g Page 2 Electrical Removable Emergency stub -up area engine supply inner tank open to bottom diptube relief vent I Subbase Fuel Tank Normal Low Additional fitting vent fuel level. for optional switch accessory o aka — o Fu11 fill with \ Fuel leak Removable fuel lockable cap and Fuel level detection switch return diptube 203 mm (8 In.) riser gauge Emergency outer tank relief vent o 00 0 0 0 0 o aka — o i I-IN oil i , i i i i i i i i 0 � o O C�7 i 00 0 0 00 o a o 0 0 0 Fu11 fill with \ Fuel leak Removable fuel lockable cap and Fuel level detection switch return diptube 203 mm (8 In.) riser gauge Emergency outer tank relief vent Note: 20- 60REOZJC models shown, other models are similar. Refer to the Basin drain ADV drawings for details. Standard Subbase Fuel Tank Features ADV -7430- • Extended operation. Usable tank capacity.offers full load • Emergency pressure relief vents. Vents ensure adequate standby operation of up to 48 hours-. venting of the Inner and outer tank under extreme pressure and /or emergency conditions. • UL listed. Secondary containment generator set base tank meeting UL 142 requirements. • Normal vent with cap. Vent Is raised above lockable fuel fill. • NFPA compliant. Designed to comply with the installation • Low fuel level switch. Annunciates a 50% low fuel, level standards of NFPA 30 and NFPA 37. condition at generator set control. • Integral external lift lugs. Enables crane with spreader -bar • Leak detection switch. Annunciates a contained primary lifting of the complete package (empty tank, mounted tank fuel leak condition at generator set control. generator set, and enclosure) to ensure safety. a Electrical stub -up. e6 -99 7/09g Page 3 - M­11 I-IN oil Note: 20- 60REOZJC models shown, other models are similar. Refer to the Basin drain ADV drawings for details. Standard Subbase Fuel Tank Features ADV -7430- • Extended operation. Usable tank capacity.offers full load • Emergency pressure relief vents. Vents ensure adequate standby operation of up to 48 hours-. venting of the Inner and outer tank under extreme pressure and /or emergency conditions. • UL listed. Secondary containment generator set base tank meeting UL 142 requirements. • Normal vent with cap. Vent Is raised above lockable fuel fill. • NFPA compliant. Designed to comply with the installation • Low fuel level switch. Annunciates a 50% low fuel, level standards of NFPA 30 and NFPA 37. condition at generator set control. • Integral external lift lugs. Enables crane with spreader -bar • Leak detection switch. Annunciates a contained primary lifting of the complete package (empty tank, mounted tank fuel leak condition at generator set control. generator set, and enclosure) to ensure safety. a Electrical stub -up. e6 -99 7/09g Page 3 State Code'Subbase Fuel Tank Options Bottom Clearance /Coating High Fuel Level Switch ❑ I- beams, provides 106 mm (4.2 In.) of ground clearance ❑ High fuel level switch ❑ Epoxy mastic coating ❑ High fuel level switch, Florida Dept. of Environmental Protection (FDEP) approved Fuel in Basin Options • Fuel in basin switch, Florida Dept. of Environmental Normal Vent Options Protection (FDEP) approved ❑ 3.7 m (12 ft.) above grade (without spill containment) . ❑ 3.7 m (12 ft.) above grade (with spill containment) Fuel FIII Options • Fill pipe extension to within 152 mm (6 in.) of bottom of fuel Tank Marking Options tank. ❑ Decal, Combustible Liquids - Keep Fire Away (qty. 2)' ❑ 18.9 L (5 gallon) spill containment with 95% shutoff ❑ Decal, NFPA 704 identification (qty. 2) ❑ 18.9 L (5 gallon) spill containment ❑ Decal, tank number and safe fuel fill height (qty. 2) ❑ 18.9 L (5 gallon) spill containment fill to within 152 mm (6 ❑ Decal, tank number and safe fuel fill height, NF PA 704 In.) of bottom of fuel tank identification ❑ 26.5 L (7 gallon) spill containment; Florida Dept. of Environmental Protection (FDEP) approved ❑ 26.5 L (7 gallon) spill containment with 95% shutoff ; Florida Dept. of Environmental Protection (FDEP). approved Fuel Supply Options ❑ Fire safety valve (installed on fuel supply line) ❑ Ball valve (installed on fuel supply line) a6-99 7109g Page 4 Enclosure and Subbase Fuel Tank Specifications 20REOZJC Lifting Base Est. Fuel Enclosure and Subbase Fuel Tank 1077 (42.4) Sound Enclosure, Sound Max. Dimensions, mm (in.) Weight, kg (Ib.) Fuel Tank Supply Hours Fuel Tank Pressure at 1513 (59.6) 1272 (2806)* 1159 (2556)* 229 (9) 379 (100) Capacity, at 60 Hz 1321 (2913)* 1208 (2663)* 330 (13) With Steel With Aluminum Height, 7 m (23 it.), L (gal.) w/Full Load Length Width Height Enclosure Enclosure mm (In.) dB(A) 20REOZJC Lifting Base 0 2320 (91.3) 1077 (42.4) 1384 (54.6) 943 (2080) 830 (1830) 100 (4) 68 254 (67) 24 1513 (59.6) 1272 (2806)* 1159 (2556)* 229 (9) 379 (100) 36 1614 (63.6) 1321 (2913)* 1208 (2663)* 330 (13) 568 (150) 48 1767 (69.6) - 1393 (3073)* 1280 (2823)* 483 (19) 20REOZJC with State Code Fuel Tankt 265 (70) 24 2896 (114) 1040 (40.9) 1522 (58.9) 1362 (3003) *. 1249 (2753)*, 229 (9) 68. 587 (155) 48 1725 (67.9) 1459 (3217)* 1346 (2967)* 432 (17) 757 (200) 72 1826 (71.9) 1514 (3338)* 1401 _&88)* 533 (21) 30REOZJC Lifting Base 0 2320 (91.3) . 1077 (42.4) 1384 (54.6) 1007 (2220) 894 (1970) 1 100 (4) 68 254 (67) 24 1513 (5976) 1336 (2946)* 1223 (2696)* 229 (9) 379 (100) 36 1614 (63.6) 1385 (3053)* 1271 (2803)* 330 (13) 568 (150) 48 1767 (69.6) 1457 (3213)* 1344. (2963)* 483 (19) 30REOZJC with State Code Fuel Tankt 265 (70) 24 2896 (114) 1040 (40.9) 1522 (59:9) 1424 (3139)* 1311 (2889)* 229 (9) 68 587 (155) 48 1725 (67.9) 1521 (3353)* 1408 (3103)* 432 (17) 757 (200) 72 1826 (71.9) 1576 (3474)* 1463 (3224)* 533 (21) 40REOZIC Lifting Base 0 2320 (91.3) 1077( 42.4) 1384 (54.6) 966 (2130) 853 (1880) 100 (4) 68 379 (100) 24 1614 (63.6) 1344 (2963)* 1231 (2713)* 330 (13) 568 (150) 36 1767 (69.6) 1416 (3123)* 1303 (2873)* 483 (19) 808 (240) 48 2021 (79.6) 1736 (3826)*. 1622 (3576)* 737 (29) 40REOZJC with State Code Fuel Tankt 378 (100) .24 2896 (114) 1040 (40.9) 1598 (62.9) 1451 (3199)* 1338 (2949)* 305 (12) 68 757 (200) 48 1826 (71.9) 1575 (3472)* 1462 (3P22)* 533 (21) 1173 (310) _ 72 2106 (82.9) 1726 (3805)* . 1613 (3555)* 819 (32) 5nREOZJC Lifting Base 0 2320 (91.3) 1077 (42.4) 1384 (54.6) 1027 (2265) 914 (2015) 100 (4) 68 379 (100) 24 1,614 (63.6) 1405 (3098)* 1292 (2848)* 330 (13) 568 (150) 36 1767 (69.6) 1477 (3258)* 1364 (3008)* 483 (19) 908 (240) 48 2021 (79.6) 1736 (3826)* 1622 (8576)* 737 (29) SnREOZJC with State Code Fuel Tankt 379 (100) 24 2896 (114) 1040 (40.9) 1598 (62.9) 1529 (3371)* 1416 (3121)* 305 (12)1.. `68 757 (200) 48 1826 (71.8) 1653 (3644)* 1540 (3394)* 533 (21) 1173 (310) 72 2106 (82.9) 1 1804 (3977)* 1691 (3727)* 819 (32) Note: Refer to the respective ADV drawings for details. * Weight Includes the generator. set (wet), enclosure, silencer, and tank (no fuel). t State code fuel tank specifications (height and weight) include I -beam option. The generator set weight represents using the largest alternator option. The enclosure weight is with acoustic Insulation added. 06 -99 7/099 Pegs 5 KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920- 565 -3381, Fax 920- 459 -1646 For the nearest sales and service outlet In the US and Canada, phone 1- 800 - 544 -2444. KohlerPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pler Road Singapore 619159 Phone (65) 6264 -6422, Fax (65) 6264 -6455 Enclosure and Subbase Fuel Tank Specifications (continued) 60REOZJC Base Est. Fuel Enclosure and Subbase Fuel Tank 1077 (42.4) Sound Enclosure, Sound 1164 (2566) 1051 (2316) 100 (4) Supply Max. Dimensions, mm (In.) Weight, kg (lb.) 1665 (65.6) Pressure at 1452 (3202)* 381 (15) 757 (200) 36 1919 (75.6) Fuel Tank Hours at Fuel Tank 7 m (23 ft.), Capacity, 60 Hz 1736 (3826)* 1622 (3576)* 737 (29) With Steel . With Aluminum Height, dB(A) with L (gal.) w/Full Load Length Width Height Enclosure Enclosure mm on.) Full Load 60REOZJC Base 0 2320 (91.3) 1077 (42.4) 1384 (54.6) 1164 (2566) 1051 (2316) 100 (4) 68 -Lifting 454 (120) 24 1665 (65.6) 1566 (3452)* 1452 (3202)* 381 (15) 757 (200) 36 1919 (75.6) 1687 (3719)* 1574 (3469)* 635 (25) 908 (240) 48 2021 (79.6) 1736 (3826)* 1622 (3576)* 737 (29) 60REOZJC with State Code Fuel Tank# 473 (125) 24 2895 (114) 1040 (40.9) 1649 (64.8) 1616 (3563)* 1503 (3313)* 356 (14) 68 908 (240) 48 1928 (75.9) 1767 (3896)* 1654 (3646)* 635 (25) 1363 (360) 72 2207 (86.9) 1918 (4228)* 1805 (3978)* 914 (36) 230REOZJE Lifting Base 0 4100 (161.4) 1300 (51.2) 1989 (78.4) 2654 (5850) 2540 (5600) 200 (8) 75 1787 (472) 28 2551(100.4) 1 3561 (7850)* 3447 (7600)* 762 (30) 230REOZJE with State Code Fuel Tankt 3573 (944) 59 15325 (209.7) 1 1300 (51.2) 1 2809(110.6) 1 4504 (9930)* 1 4391 (9680)* 1 1020 (40) 75 25OREOZJE Lifting Base 0 4100 (161.4) 1300 (51.2) 1 1989 (78.4) 2699 (5950) 2585 (5700) 200 (8) 75 1787 (472) 24 2551(100.4) 3606 (7950)* 3493 (7700)* 762 (30) 25OREOZJE with State Code Fuel Tankt 3573 (944) 1 54 15325 (209.7) 1 1300 (51.2) 1 2809(110.6) 4550 (10030)* 1 4436 (9780)* 1 1020 (40) 75 275REOZJE Lifting Base 0 4100 (161.4) 1300 (51.2) 1989 (78.4) 2835 (6250) 2722 (6000) 200 (8) 7S 1787 (472) 24 2551(100.4) 3742 (8250)* 3629 (8000)* 762 (30) 275REOZJE with State Code Fuel Tankt 3573 (944) 1 48 15325 (209.7) 1 1300 (51.2) 1 2809(110.6) 1 4686 (10330)* 1 4572 (10080)* 1020 (40) 75 Note: Refer to the respective ADV drawings for details. * Weight Includes the generator set (wet), enclosure, silencer, and tank (no fuel). t State code fuel tank specifications (height and weight) Include I -beam option. The generator set weight represents using the largest alternator option. The enclosure weight Is with acoustic Insulation added. Availability Is subject to change without notice. Kohler Co, reserves the rightto change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler® generator set distributor for availability. DISTRIBUTED BY- 0 2008, 2009 by Kohler Co. All rights reserved. GB-99 7/09g Page 6