HomeMy WebLinkAbout3331 SILLECT AVENUE_HMBP 4.6.11UNIFIED PROGRAM INSPECTION CHECKLIST
SECTION 1: Business Plan and Inventory Program
•
A
4�A L D
FIRE
RTM r
BAKERSFIELD FIRE DEPT.
Prevention Services
2101 H Street
Bakersfield, CA 93301
Tel.: (661) 326 -3979
Fax: (661) 852 -2171
FACILITY NAME
t^ c-1�U ��r � t.� 7 v r^,OT') u G P�1 P�
INSPECT ON DATE
� 61,11
INSPECTION TIME
ADDRESS
4 I LLE &T UC
PHONE NO.
.-7
NO OF EMPLOYEES
FACILITY CONTACT
BUSINESS ID NUMBER
Consent to Inspect Name /Title
/C7U Gb 4 I 5
Section 1: Business Plan and Inventory Program
❑ ROUTINE O::'COMBINED ❑ JOINT AGENCY ❑ MULTI - AGENCY ❑ COMPLAINT ❑ RE- INSPECTION
C v
c C= Compliance OPERATION
V= Violation
COMMENTS
��o
APPROPRIATE PERMIT ON HAND
(BMC: 15.65.080)
❑ [X
Business PLAN CONTACT INFORMATION ACCURATE
(CCR: 2729.1)C
3- ❑
VISIBLE ADDRESS (CFC: 505.1, BMC: 15.52.020)
t
Do ❑
CORRECT OCCUPANCY'
(CBC: 401)
❑+O ❑
VERIFICATION OF INVENTORY MATERIALS
(CCR: 2729.3)
LJ1 ❑
VERIFICATION OF QUANTITIES
(CCR: 2729.4)
0q) ❑
VERIFICATION OF LOCATION
(CCR: 2729.2)
19c, ❑
PROPER SEGREGATION OF MATERIAL
(CFC: 2704.1)
�a ❑
VERIFICATION, OF MSDS AVAILABILITY
(CCR: 2729.2(3)(b))
0:-D ❑
VERIFICATION OF HAZ MAT TRAINING
(CCR: 2732)
❑ ❑
VERIFICATION OF ABATEMENT SUPPLIES & PROCEDURES (CCR: 2731(c))
^177 ❑
EMERGENCY PROCEDURES ADEQUATE
(CCR: 2731)
❑ ❑
CONTAINERS PROPERLY LABELED (CCR: 66262.34(f), CFC: 2703.5)
E�,.=�D
HOUSEKEEPING
(CFC: 304.1)
,CO ❑
FIRE PROTECTION
(CFC: 903 & 906)
❑` 0 ❑
SITE DIAGRAM ADEQUATE & ON HAND
(CCR: 2729.2)
ANY HAZARDOUS WASTE ON SITE? n-yYES ❑
NO
Signature of'Recei
Explain:
\,-)Q
POST INSPECTION INSTRUCTIONS:
• Correct the violation(s) noted above by
• Within 5 days of correcting all of the violations, sign and return a copy of this page to:
Bakersfield Fire Dept., Prevention Services, 2101 H Street, California 93301
�8lgnature (that all violations have been corrected as not
,Date /
While — Business Copy Yellow — Business Copy to be Sent in after return to Compliance Pink — Prevention Services Copy I FD2155 (Rev 600)
HAZARDOUS WASTE BAKERSFIELD FIRE DEPARTMENT
UNIFIED PROGRAM CONSOLIDATED FORMS R S F I Prevention Services
/ /sj 1501 Truxtun Ave 1sT FLR
HAZARDOUS WASTE GENERATOR k1mr-IsrBakersfield, CA 93301
INSPECTION REPORT Phone: 661 - 326 -3979 . Fax: 661- 852 -2171
) r A J
I7 124'' +�l.l U �� C3I^^4 ► ! V �Cy.E /'AI � Date G/
Facility Name �
Site Address S / LL a .,r A V t Time in Time Out
Owner /Operator Phone S ' 7 ! Misc.
Type of Inspection Inspection Consolidation EPA ID # M'
❑ Routine ❑ Re- inspection/Follow -up ❑ Combined Routine Inspection ❑ Joint Inspection ❑ Complaint ❑ Focused ❑ Other
f
❑ Integrated or Multi -Media Inspection CUPA Facility [D# :?
❑ CONSENT TO INSPECT GRANTED BY (Name/ Title): +t
Inspection may involve obtaining photographs, review and copying of records, and determination of compliance with hazardous waste handling requirements.
1 _ C ba I Vinlatinn ii _ (•lace 11 Vinlatinn M _ Min— Vinlatinn Pape of
I
II
M
HAZARDOUS WASTE REQUIREMENTS
Code I I
Y N
I I
N/A
I
COMMENTS /NOTES/DOCUMENT(S) REVIEWED
MISSING INFORMATION/ UNRESOLVED ISSUES
Recordkee in documentation
GR01
Generator has an EPA ID number
GR02
Hazardous waste determination made for all wastes
❑ Analysis N<4 Generator Knowledge
GR03
Contingency lan information posted near phone
GR04
Facility personnel demonstrate training/awareness k
7
GR05
I Manifests/Consolidated Manifest receipts complete _
o
'f'• c. , w •1 , _ ?, C . { ) ,_
GR06
Blue co (s) of manifest mailed to DTSC
1
GR07
TSDF signed copy of manifest available Win 35
days of waste shipment
j
•,
GRO8
Bills of Lading/receipts available
?
GR09
LDRs available and com lete
GR10
Onsite recycling reported using UPCF
Container /tank mane ement
GC01
Containers are in good condition
1
GCO2
Containers are closed except when'addin removin
GC03
Empty containers are empty
T
GC04
Containers inspected week)
GC05
Tanks inspected Bail
GC06
Satellite containers at or near point of generation
_
GC07
Satellite containers under control of operator
o
GC08
One container per wastestream at satellite area
GC09
Exclude recyclable materials stored in accordance 1
with local ordinance/hazardous materials codes
Accumulation Time Limits
GAOL
Waste is accumulated not more than 90/180/270
T�
GA02
Satellite wastes accumulated for less than 1 year `x
.
GA03
Empty containers managed within one year
GA04
Universal waste accumulated less than one year
0
GA05
Used oil filters offsite within 180 (1 year if <1 ton)
1
GA06
I Pb -acid batteries offsite within 180 I yr. if < I ton))
Labeling/Marking
GLOI
Containers are properly labeled
GL02
Satellite containers have 2" ASD marked once full -
GL03
Excluded rec clable materials marked properly k
GLO4
Universal waste container properly labeled
GL05
Used oil filters marked "drained used oil filters"
GLO6
Date written on spent lead -acid batteries
GL07
"Used Oil" marked on all used oil tanks/containers
GL08
Tank marked with "haz waste" , contents, start date
-
GL09
Empty containers marked with date emptied
Treatment Trans rt and Disposal/Other
i
Print and sign in this box for receipt of this report. Signature does
not imply-agreement with findings, only receipt of report.
! ,- r�•!+a''' G- °f b ` %
GT01
Have permit/authorization to do treatment
GT02
Waste sent with authorized transport (en. eligible)
GDOI
GHOI
Waste disposed of to authorized point/party
Failed to properly handle appliance wastes
I'O51 1NbirtullON INMKUCI'IUNJ: %
• Refer to the back of this inspection report for regulatory citations and corrective actions
• Correct the violation(s) noted above by Signature (that all violations have been corrected as noted)
• Within 5 days of correcting all of the violations, sign and return a copy of this page to:
Bakersfield Fire Dept., Prevention Services, 1501 Truxtun Avenue, California 93301
Date
FD2179 (Rev I0RI /08)
While - Prevention Services Copy Yellow- Business Copy
v
Reeulatory Citations and Corrective Actions
Uescri tion of violation I Regulatory /statutory citation I Corrective actions to be taken or minor violations (marked in the "Al" column on 'runt)
GRO I
The facility failed to obtain an EPA ID number [Title 22, CCR, 66262.121 For a CaUlbrnia EPA ID # contact the Department gf'Toxic Substances ConO•ol at
I -S00 -61,4 -6942. For a EPA ID # call 415- 495 -8895. IVrite the number in the space market/ "EP.4 ID # " on the front ofthis xrge.
GR02
The facility failed to make a waste determination for the noted in the
[Title 22, CCR, 66262.111 Make a determination of the waste based on pour knowledge (you can use AISDS or other documnents.for help) or have the waste
stun led and .cent to a .dente certified laboratory for analsis. 11 sam sling is conducted tell the lab to anal ze for
GR03
The facility did not have the name and phone number of the emergency coordinator, the location of fire extinguishers and spill control equipment, or the fire
department telephone number posted next to the telephone. "Title 22, CCR, 66262.34(d)(2)] Pre are and post the above information ilea to a phone.
GR04
Facility personnel did not demonstrate that they were familiar with proper waste handling procedures due to
`Title 22, CCR, 66262.34(4)(2) Provide training to penvollnel regarding
GR05
The facility failed to properly complete a hazardous waste manifest. Manifest # was missing
[Title 22, CCR, 66262.23(a)(1)]. Correct the iafor•nration on the manifest in Box(es) initial and date. Subrrhii a letter to DISC. G'ISS: r P.O.
Box 4116 Fdrl -l: Sacramento, CA 95812 - 164(16 stating the manifest #. the ship date, )roar EP.4 ID #. the Box # and correction made and your signature.
(Correction for more than one manifest nuav be included in the same letter)
GR06
Facility failed to submit a copy of the manifest to DTSC within 30 days of shipment. [Title 22, CCR, 66262.32(x)(4)] rblail the blue copy ofmanifest
# to: DTSC. PO Box 400. Sacramento. CA 9 5 8 1 2 -114 0 0 or a photocopv ofthe TSDF co pi; to: DTSC. PO Box 3000, Sacramento. C.4 95812
GR07
The facility failed to file an exception report to DTSC after not receiving the signed TSDF copy of a manifest within 35 clays. [Title 22, CCR, 66262.421
Make a cope oJ'the manifest and send if with a letter to DTSC. PO Bon XXX, Sacramento, CA 95812 starting what you are doing to,find out wlp.You have not
received the final. signed co v of the manilesL Include a sr.Qnatm'e anti Polo- inndin s while looking for the nnani /evt in the corer- letter.
GROS
The facility failed to have copies of receipts for the removal of . [HSC 25160.2 - Consolidated manifests/ 66266.81(a)(6)(B)-
lead acid batteries /66266.130- oil filters The facility shall contact and net uesi copies ofrecei is between &
GR09
The facility failed to complete or maintain a Land Disposal Restriction notification for manifest # [Title 22, CCR, 66262.34(a)(4)]
The facility shall determine if its waste is subject to LDR yea uirements, and i /'so. erasure that a LDR is relmi-ed and submitted with each shipment oflvaste.
GR 10
The facility did not submit a recycling report [Fl SC: 25143.10] Thefcility shall complete and submit the UPCF.16nn "Recvelable rb/aterials Report ". The
form can befound at www.calepa.ca.,—,ov/publications/title27/default.litiii (Hit- i•eeve.pdf)
GC'OI
The facility failed to maintain containers holding hazardous waste in good condition. The container of was
Title 72, CCR, 66262.34(a)(1)(A) The conntents of'the eontairher of .shall inn uediaelh- be transferred to a container in good condition
GCO2
The facility failed to keep containers closed except when adding /removing waste. The container of was observed open [Title 22, CCR,
66262.34(a)(1)(A) . The futility shad/ immediatelv c lose till containers and ensure that containers remain closed excex when adding or removing waste.
GC03
The facility is handling contaminated containers as empty when they are not. A container of was noted as not meeting the definition of
empty. [Title 22, C'CIZ, 66261.7] The fiwilirn shall Ina rk the container as hazardous waste or consolidate the contents of the container
with a like waste and immediael- label the emptied container with the words "em ry" and fire (late.
GC04
The facility could not demonstrate that containers were being inspected weekly. [Title 22, CCR, 66262.34(a)(I )(A)] Thejacilit v shall develop and implement
a plan that ensures that all containers holding waste are inspected weekly
GC05
The facility could not demonstrate that tanks were being inspected daily. [Title 22, CCR, 66262.34(a)(1 )(A)] The facility shall keep a log showing that tanks
holding waste are inspected dail.
GC06
Containers utilizing satellite accumulation rules were not at or near the point of generation. [Title 22, CCR, 66262.34(e)(1)(A)] The fircilih+ shall more dre
container holding to a location that is art or near the point of generation or shall ensure that the raarste is removed within 90114111270
days of first dt-op of waste being added. (ifthe facilin-,generates less than /lilt kg. the clock aloes not start until 100 kg. are generated)
GC07
Containers utilizing satellite accumulation rules were not under the control of an operator. [Title 22, CCR, 66262.34(e)(1)(A)] The "lhcility shall ensure that
an operator is at or near the point ofaccumulation or' shall ensure that the waste is reproved within 9011801270 done o/ first th- of'waste being added
GCO8
The facility kept more than one satellite container of at a satellite accumulation area. [Title 22, CCR, 66262.34(e)(1)] Thefacility
shall inunediate /i remove all ball one container f -onl the accumulation area or .dual/ demonstrate that it is not Jractica/ or safe to do such.
0009
The facility stored excluded recyclable materials not in accordance with local ordinance /tire code /hazardous materials codes [HSC 25143.9(c)] The /hcility
shall return to code by
GAO]
The lacilily accumulated waste lit greater than allowed time limits (Storage without a pennit). A container of had an start (late of
marked on it. [l'itle 22, CCR, 66262.34(x)] Thefacility shall imunediatcly arrange,for the rennoval of the waste, and shall supple a caps of the nraanjfest or bill
or- lading demonso-atin,g removal hvithin clays.
GA02
The facility held satellite accummlation wastes for greater than one vear. 'Title 22, CCR, 66262.34(e)(1)(B)l See GAM above far corrections.
GA03
The facility failed to properly handle contaminated containers within I vear. Title 22, CCR, 66261.7(t) See G.401 above for corrections.
GA04
The facility held universal wastes for greater than one vear. Title 22, CCR, 66273.I5(a) or 66273..35(a)l See GA01 above fa. corrections.
GA05
The facility held drained used oil filters for greater than 180 days /one vear. Title 22, CCR, 66266.130(c)(4) .See 6.401 above for corrections.
GA06
The facility held lead acid batteries for greater than 180 days/one vear. ITitle 22, CCR, 66268.81(a)(6) See GA01 above for corrections.
GLOl
The facility failed to properly label all containers. Containers, contents and missing information are noted on the front of this page. ["Title 22, CCR,
66262.34(1)] The ftacilit shall clearIv nark all containers with the following: 1) the words "Hazardous same ", 2) composition and pitvsical state. 3) hazard
property. 4) name and address of the generator. and 5) accumulation snarl date.
GL02
The facility failed to mark the date the container was moved from the satellite accumulation area [Title 22, CCR, 66262.34(c)(1)(B)l Thefacilifv shall mark
all satellite accunndation with the date waste is first added as well as the date the container is full.
GI-03
The facility failed to mark tanks /container(s) of excluded recyclable materials properly [HSC 25143.9(a)] The tanks /containers ol'materialr shall be clear•iv
marked with the words "Evcluded recvclable material" instead of"hazardous waste ".
61-04
The facility failed to murk a container of universal waste properly. [Title 22, CCR, 66273.14 for SQH or 66273.34 for LQH [. The fircilirn shall irmnetliaely
mark all containers holding universal waste with the words "Universal Waste- "
GI -05
The facility failed to mark a container ofdrained used oil filters with the words "drained used oil filters ". [Title 22, CCR, 66266.130(c)(3)] The acilit shall
mark all filter containers with the words "drained used oil filters ".
GL06
The facility failed to mark the date on which the battery was received. Title 22, CCR, 66266.8 1 (a)(6)(D)] The locility shall y mark the date on each batterv.
GL07
The facility failed to mark a tank /container of used oil destined for recycling with the words "used oil" [HSC 25143.9(x)] Clearll nark all tanks and
containers with the words "used oil ".
GLOS
The facility failed to mark the tank of with the [Title 72, CCR, 66234(1)] The acilitv shall
elearlh nuo•k the rank with
GL09
The facility failed to mark contaminated containers with the date emptied. I Title 22, CCR, 66261.7(t) I Clear/- mark all containers with the date enlinied.
GHOI
The facility failed to remove from an appliance prior to crushing, baling, shredding, sawing or disposing of the appliance [HSC
25212(a) . The futility H n a urst submit to DTSC a ) locaion to be certified as a " Certilied .4 fiance Recvc /er "
GT01
The facilit • failed to obtain a permit or other authorization for treatment of hazardous waste. I -ISC 25I89.5(cl)
GT02
The facility failed to use a registered transporter/used a transporter or consolidated waste when they were not eligible tISC 25165(a)/25160
GDOI
The facility disposed of hazardous waste at an unauthorized point. HSC 25189.5(a)