HomeMy WebLinkAbout8110 ROSEDALE HWY (2)JORGENSEN CO STATE FIRE MARSHAL A -0309 / CONTRACTORS LICENSE C16 CIO C7 9313AKERSFIELD . (661)3274 352 ❑FRESNO (559) 268 -6241 OMERCED .(209) 383 -6647 OMODESTO (209) 529 -0835 Name: )�- % tl /', l /v - 77 3 �A-1 RANGE HOOD'SYSTEM REPORT Address: / / (���_ ✓(1l-t //I / City: Jurisdiction: Code: DATE OF SERVICE T56 /J,-) / 3 4 I ACR 4,1 S L' I 1 MODEL NUAt sR 4 10— 7 DAY C LIN] FR SI M MASTER OTHER MINDER LOCATION O�F% GAS SVVALVE, FUSE UM 360 QTY. FUSE LM 430 QTY. FUSE LINK 500 QTY. oTr1FR ' LDIRS REPLACED FUEL. SLiIJI- OFF GAS ' Y7 NO TESTED �� NO � AEI �C i MANUAL PULL OPERABLE DETECTION LANE OPFRABIpJUNF7LAYED ALL NOZZLES REMOVED CLEANED PER J CO ! MANUFACTURES SPECIFICATIONS �//^^�� ,� P NO � r NO F—� YFB NO lam%' LOCATION OF SYSTEM ANSUL SEAL. CART. / _7C.• / / , .!� /i � .� YES NO HOOD ! SIB DUCT SIM MANAGER,'S NAME / PHONE NUMBER COOKING APPLIANCES LOCATION: LEFT TO RIGHT WITH SIZES 1� 2 3 4 5 6 7 8 ?SPORT EACH SYSTEM WITH ANY OF THESE PROBLEMS: ❑ Additional nozzles are required for: ❑ Electric or Gas cut -off must be installed to prevent a fire from reigniting per N.F.P.A 96,1 7 &17A codes. ❑ Additional fire detectors are required to assure reliable fire detection. ❑ This system is designed for coverage with no more than a fight grease buildup. Grease buildup appears excessive. We recommend the exhaust system be professionally cleaned. Initials ❑ Because of the age and/or condition of this fire control system it may fail and should be replaced with a new system. Initials ❑ ON THIS DATE CUSTOMER WISHES NOT TO HAVE THIS SYSTEM SERVICED. Comments: On this date the above system was inspected in accordance with the State Fire Marshal regulations, the manufacturer's manual, and Jorgensen Co. service manual. SERVICE TECHNICIAN Are all external hood penetrations sealed, welded or sealed with a UL device? YES'` NO Is pressure gauge in operable range? �L�-YES - -NO- 3. Record 6 year maintenance due date. 4. Record Hydrostatic due date. 5. Record 12 Year regulator test due date. 6. Are cartridge's weights within acceptable limits? YES,-NO 7. Is the proper extinguisher in place and serviced? ENO 8. Are the exhaust fans working? l YES,-.NO 9. Next due date for extinguisher service..) 10. Next due date for extinguisher hydro. (� ✓ ✓/ c.- 11. Is this system a U.L. 300? MONO ❑ With the introduction of Vegetable oil in place of animal fat, U.L. has changed it's standard to extinguish grease fires. We understand you are using this type of oil. We recommend upgrading to the new standard to assure you have the proper fire protection Initials I have been instructed on and understand the operation of this system. CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated m this report. WHITE - CUSTOMER COPY CANARY - JORGENSEN PINK - AUTHORITY HAVING JURISDICITON