HomeMy WebLinkAboutSPRINKLER TEST 5/17/2010Design, Installation, Inspection, & Repair of Fire Sprinkler Systems Bakersfield San Francisco Livermore DATE: May 2010 We herewith enclose a copy of an automatic fire sprinkler system check report for the following facility: Barnett Tire Company 98 Oak Street Bakersfield, CA 93304 to the party checked below: Owner: Fire Dept: Thank You RLH Fire Protection File: 7098 cc: Barnett Tire Company 98 Oak Street Bakersfield CA 93304 b U 1- 32 -tai /1 Bakersfield City Fire Department Fire Prevention Division 1500 Truxtun Avenue Bakersfield, CA 93301 R L H Fire Protection 3430 Unicorn Rd. Bakersfield, CA 93308 Voice:661.322.9344 Fax:661.322.6816 Lic.# 777717 Inspection, Testing, and Maintenance Fire Sprinkler System NFPA 25 Chapter 5 as amended by CCR Title 19 Abbreviation Key: I =Inspection T =Test M = Maintenance A -O = After Operation MI = Per Manufacturer's Instructions Date Of Inspection, Testing, Maintenance: 05/17/2010 System Riser ID: 7098 Description Property Information: Fail N/A Pass 1.1 1 Type Of System: ¢ Cq C�,009 Name: Barnett Tire Company ® Wet Pipe Address: 98 Oak Street I ❑ Dry Pipe Dry Pipe Valves - Enclosure temperature 12.4.4.1.1 ❑ Preaction 1.3 I ❑ DelugeE Gauges - (Dry, Preaction, Deluge Systems) City: Bakersfield X Main Drain Test Results: Initial Static Pressure: (psi) Residual Pressure: (psi) Restored Static Pressure: (psi) Abbreviation Key: I =Inspection T =Test M = Maintenance A -O = After Operation MI = Per Manufacturer's Instructions Item Activity Frequency Description NFPA 25 Reference Fail N/A Pass 1.1 1 Daily Weekly Preaction /Deluge Valves - Enclosure temperature 12.4.3.1 X 1.2 I Daily Weeklv Dry Pipe Valves - Enclosure temperature 12.4.4.1.1 X 1.3 I Quarterly Gauges - (Dry, Preaction, Deluge Systems) 5.2.4.2 5.2.4.3 X 1.4 1 Quarterly Control Valves 12.3.2.1 X 1.5 1 Quarterly Alarm Devices 5.2.6 X 1.6 I Quarterly Gauges (Wet Pipe Systems) 5.2.4.1 X 1.7 I Quarterly Hydraulic nameplate 5.2.7 X 1.8 1 Quarterly Pipe and Fittings 5.2.2 X 1.9 1 Quarterly Sprinklers 5.2.1 X 1.10 1 Quarterly Spare Sprinklers 5.2.1.3 X 1.11 I Quarterly Fire Department Connections 12.7.1 X 1.12 I Quarterly Alarm Valves - Exterior Inspection 12.4.1.1 X 1.13 I Quarterly Quarter) Preaction /Deluge Valves - Exterior Inspection 12.4.3.1.6 X 1.14 1 Quarterly Pressure Reducing Valves 12.5.1.1 X 1.15 1 Quarterly Dry Pipe Valves- Exterior Inspection 12.4.4.1.4 X 1.16 1 Quarterly Backflow Preventers 12.6.1 X 1.17 1 Annual Buildings 5.2.5 X State Fire Marshal AES 2 March 21, 2006 Inspection performed by: RLH Fire Protection - Bakersfield, CA - 777717 Page 1 of 5 ANNEX B State Fire Marshal AES 2 March 21, 2006 Inspection performed by: RLH Fire Protection - Bakersfield, CA - 777717 Page 2 of 5 Inspection, Testing, and Maintenance Fire Sprinkler System NFPA 25 Chapter 5 as amended by CCR Title 19 Activity Date Of Inspection, Testing, Maintenance: 05/17/2010 System Riser ID: 7098 NFPA 25 Reference Property Information: N/A Type Of System: IF CACr� Name: Barnett Tire Company ® Wet Pipe Q�f op Address: 98 Oak Street ❑ Dry Pipe 1.19 1 ❑ Preaction Seismic Braces 5.2.3 ❑ Deluge f� i�' E � City: Bakersfield 1 5 Years Hangers (Accessible concealed spaces) State Fire Marshal AES 2 March 21, 2006 Inspection performed by: RLH Fire Protection - Bakersfield, CA - 777717 Page 2 of 5 " Item Activity Frequency Description NFPA 25 Reference Fail N/A Pass 1.18 1 Annually Hangers 5.2.3 x 1.19 1 Annually Seismic Braces 5.2.3 x 1.20 1 5 Years Hangers (Accessible concealed spaces) 5.2.3.3 x 1.21 I 5 Years Seismic Braces (Accessible concealed spaces) 5.2.3.3 x 1.22 1 5 Years Pipe and Fittings (Accessible concealed spaces) 5.2.2.3 x 1.23 1 5 Years Sprinklers (Accessible concealed spaces) 5.2.1.1.4 x 1.24 1 5 Years Alarm Valves - Interior Inspection 12.4.1.2 x 1.25 1 5 Years Alarm Valves - Strainers, filters, orifices 12.4.1.2 x 1.26 1 5 Years Check Valves - Interior Inspection 12.4.2.1 x 1.27 1 5 Years Preaction /Deluge Valves - Interior Inspection 12.4.3.1.7 x 1.28 I 5 Years Preaction/Deluge Valves - rainers, filters, orifices 12.4.3.1.8 x 1.29 1 5 Years Dry Pipe Valves - Interior Inspection 12.4.4.1.5 x 1.30 1 5 Years Dry Pipe Valves - Strainers, filters, orifices 12.4.4.1.6 x 2.1 T Annually Alarm Devices (90 Sec) 5.3.3 12.2.7 x 2.2 T Annually Main Drain Test (Enter data on Page 1) 12.2.6 12.2.6.1 12.3.3.4 x 2.3 T Annually Antifreeze Test 5.3.4 x 2.4 T Annually Control Valve - Position 12.3.3.1 x 2.5 T Annually Control Valve - Operation 12.3.3.1 x 2.6 T Annually Supervisory 12.3.3.5 x 2.7 T Annually I Preaction Valve - Priming Water 12.4.3.2.1 x 2.8 T Annually Preaction Valve - Low Air Pressure Alarm 12.4.3.2.10. x 2.9 T Annually Preaction Valve - Full Flow Trip Test 12.4.3.2.2 x State Fire Marshal AES 2 March 21, 2006 Inspection performed by: RLH Fire Protection - Bakersfield, CA - 777717 Page 2 of 5 ANNEX B State Fire Marshal AES 2 March 21, 2006 Inspection performed by: RLH Fire Protection - Bakersfield, CA - 777717 Page 3 of 5 Inspection, Testing, and Maintenance Fire Sprinkler System NFPA 25 Chapter 5 as amended by CCR Title 19 Date Of Inspection, Testing, Maintenance: 05117/2010 Property Information: Name: Barnett Tire Company Address: 98 Oak Street City: Bakersfield System Riser ID: 7098 Type Of System: of CgL�i� ® Wet Pipe ❑ Dry Pipe `� n ❑ Preaction ❑ Deluge ARE M Item Activity Frequency Description NFPA 25 Reference Fail N/A Pass 2.10 T Annually Dry Pipe Valve - Priming Water 12.4.4.2.1 X 2.11 T Annually Dry Pipe Valve - Low Air Pressure Alarm 12.4.4.2.6 X 2.12 T Annually Dry Pipe Valve - Quick- Opening Device 12.4.4.2.4 X 2.13 T Annually Dry Pipe Valve - Trip Test 12.4.4.2.2 X 2.14 T Annually Backflow Preventor Assemblies 12.6.2 X 2.15 T 3 Years Dry Pipe Valve - Full Flow Trip Test 12.4.4.2.2.2 X 2.16 T 5 Years Gauges 5.3.2 X 2.17 T 5 Years Pressure Reducing Valve 12.5.1.2 X 2.18 T 5 Years Fire Department Connection Backflush 12.7.4 X 2.19 T 5 Years Sprinklers - Extra High Temperature 5.3.1.1.1.3 X 2.20 T 5 Years Sprinklers - Corrosive environment or corrosive water 5.3.1.1.2 X 2.21 T 10 Years Sprinklers - Dry 5.3.1.1.1.5 X 2.22 T 20 Years Sprinklers - Fast Response 5.3.1.1.1.2 X 2.23 T 50 Years Sprinklers 5.3.1.1.1 X 2.24 T 75 Years Sprinklers 75 years in service 5.3.1.1.1.4 X 2.25 T Sprinklers manufactured prior to 1920 - Replace 5.3.1.1.1.1 X 3.1 M Annually Control Valves 12.3.4 X 3.2 M Annually Preaction /Deluge Valves 12.4.3.3.2 X 3.3 M Annually Dry Pipe Valves /Quick- Opening Devices 12.4.4.3.2 X 3.4 M Annually Dry Pipe Valve - Low Point Drains 12.4.4.3.3 X 3.5 M 5 Years Obstruction Investigation Chapter 13 X State Fire Marshal AES 2 March 21, 2006 Inspection performed by: RLH Fire Protection - Bakersfield, CA - 777717 Page 3 of 5 ANNEX B Inspection, Testing, and Maintenance Fire Sprinkler System NFPA 25 Chapter 5 as amended by CCR Title 19 Date Of Inspection, Testing, Maintenance: 05/17/2010 Property Information: Name: Barnett Tire Company Address: 98 Oak Street City: Bakersfield System Riser ID: 7098 Type Of System: F CaC��o ® Wet Pipe ❑ Dry Pipe c ❑ Preaction -tr � E] Deluge EM Item Deficiencies and Comments: Deficiencies and Comments Item number must correspond to to the Item number of the activity listed above: ❑ See Continuation Page(s) (Indicate the number of continuation pages) x PASS -0 ,_n ❑ ❑ FAIL INN/ 05/17/2010 Signature Date State Fire Marshal AES 2 March 21, 2006 Inspection performed by: RLH Fire Protection - Bakersfield, CA - 777717 Page 4 of 5 California Inspection/Test Quarterly Wet 5/17/2010 Property: Barnett Tire Company Owner: =r Design, UaO* hip obon end Repe6 of Fa Spdn u Systems Inspection Ref: 7098 Deficiency Summary These items were deficient and do not meet the requirements of the applicable code at the time of the inspection. Items marked Recommendation are not required by the applicable code but are opportunities to improve the Life Safety of the property. 7098 System Riser ID Last Five Year Service: 05/04/2004: Due Now B. Barillas I state that the information on this form is correct at the time and place of my inspection, and that all equipment tested at this time was left in operational condition upon completion of this inspection except as noted. Last Five Year Service: 05/04/2004 Inspection performed by: RLH Fire Protection - Bakersfield, CA - 777717 Page 5 of 6