Loading...
HomeMy WebLinkAbout11-110 TY Lin SR-178_Morning Drive Interchange Final GDR 120801 - Table 727 Earth Mechanics, Inc. Geotechnical & Earthquake Engineering Table 6. In-Situ Soil Infiltration Rates at Detention Basins Basin No. Boring No. Approx. Ground Surface Elevation (ft) Approx. Ground Water Elevation (ft) USCS Classification Infiltration Rates Test Well (in/hr) Site Average (in/hr) 1 A-12-91 +821.0 NE SP-SM, SM 0.11 0.20 A-12-92 +824.0 NE SM, SP 0.28 2 A-12-95 +711.0 NE SC, SM 0.36 0.30 A-12-96 +704.0 NE SM, SP 0.12 A-12-98 +707.0 NE CL, ML, SM 0.41 3 A-12-93 +796.0 NE SM 0.24 0.16 A-12-94 +784.2 NE SM 0.16 A-12-97 +788.0 NE SM, SC 0.08 Notes: NE = Not Encountered For the design of detention basins, the City of Bakersfield requires either a double-ring infiltrometer test (ASTM D 3385) or a laboratory permeability test (ASTM D 2434 or D5084) to determine the infiltration rate of site soils at basin locations. Since the invert of Basin 3 is approximately 10-15 ft below existing grade, double-ring infiltrometer test at the invert of the basin could not be performed; therefore, a constant head permeability test (ASTM D 2434) was performed on remolded samples compacted to 90% relative compacted per CT 216. The results of the laboratory permeability tests for Basin 3 are provided in Table 7 below. Table 7. Laboratory Soil Infiltration Rates Conducted on Remolded Samples – Basin 3 Basin No. Boring No. USCS Classification Max. Dry Density per CT 216 (pcf) Remolded Density of Sample Tested (pcf) Permeability Test Result (in/hr) Average (in/hr) 3 A-12-93 SP-SM 120.5 108.6 0.17 0.10 A-12-97 SM 115.5 104.3 0.03 Global Stability. The “global stability” of the detention basin embankments was evaluated using the computer program Slide 5.0 (Rocscience, 2006) under both static and pseudo-static conditions. One cross section was cut along each basin where the embankment was tallest. Two additional conditions for the detention basin embankments were also considered as part of the “global” stability analysis; the steady state maximum pool condition and the rapid drawdown from the maximum pool condition. The maximum pool condition assumes that the detention basin is completely full to the crest of the lowest surrounding embankment and the embankments are fully saturated. The rapid drawdown from the maximum pool condition assumes that the detention basin drains instantaneously from the maximum pool condition and the surrounding embankments remain saturated. The phreatic surface for the rapid drawdown condition is at the ground surface within the basin. Analyses were performed using the design parameters in Section 8.1.1. The minimum required factor of safety for a permanent slope is 1.5 for the static and maximum pool condition, 1.2 for the rapid drawdown condition and 1.1 for the seismic condition per Caltrans Guidelines (2006a). Global stability calculations are provided in Section 13.10.